@zwave-js/config 8.9.1 → 8.10.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/config/devices/0x000c/hs-wd200.json +19 -17
- package/config/devices/0x000c/hs-wx300.json +46 -73
- package/config/devices/0x000c/templates/homeseer_template.json +32 -0
- package/config/devices/0x001a/rf9640.json +59 -73
- package/config/devices/0x003b/jbe109.json +29 -52
- package/config/devices/0x003b/jfe109.json +133 -0
- package/config/devices/0x003b/s-6500f.json +13 -13
- package/config/devices/0x0060/an301.json +17 -0
- package/config/devices/0x0063/39348_54890_54891_zw4008.json +2 -2
- package/config/devices/0x0063/39354_54912_zw4009.json +2 -2
- package/config/devices/0x0063/43072_zw4008dv.json +5 -5
- package/config/devices/0x0063/43074_zw4009dv.json +5 -5
- package/config/devices/0x0063/43105_zw3014.json +2 -2
- package/config/devices/0x0063/43107_zw3015.json +2 -2
- package/config/devices/0x0063/46201.json +3 -2
- package/config/devices/0x0063/46202.json +23 -2
- package/config/devices/0x0063/46562_zw4008.json +2 -2
- package/config/devices/0x0063/52190_zw7105.json +12 -5
- package/config/devices/0x0063/56590_56592_zw3012.json +200 -0
- package/config/devices/0x0063/64637_zw7105.json +50 -0
- package/config/devices/0x0086/templates/aeotec_template.json +23 -14
- package/config/devices/0x0086/zw141.json +5 -0
- package/config/devices/0x0090/{893.json → hc620.json} +13 -8
- package/config/devices/0x0094/2gig-edg-n.json +28 -0
- package/config/devices/0x0094/adc-sg130z.json +28 -0
- package/config/devices/0x0094/tboost-a_2.json +27 -0
- package/config/devices/0x0094/tboost-t_2.json +27 -0
- package/config/devices/0x009b/2gig-stz.json +1 -1
- package/config/devices/0x0109/za1021-7.json +27 -0
- package/config/devices/0x0109/zp3113-7.json +135 -0
- package/config/devices/0x010e/danalock_v3-btze.json +37 -21
- package/config/devices/0x010f/fgbs222.json +239 -185
- package/config/devices/0x010f/fghc3-001.json +27 -0
- package/config/devices/0x010f/fgt001.json +0 -1
- package/config/devices/0x010f/fgwdeu.json +28 -39
- package/config/devices/0x010f/hc3l-001.json +27 -0
- package/config/devices/0x010f/yh-001.json +27 -0
- package/config/devices/0x0112/itb-5104.json +27 -0
- package/config/devices/0x0129/templates/yale_template.json +15 -0
- package/config/devices/0x0129/yrc216-zw3.json +245 -0
- package/config/devices/0x0129/yrc226-zw3.json +76 -0
- package/config/devices/0x0129/yrc256-zw3.json +76 -0
- package/config/devices/0x0129/yrd216-zw3.json +76 -0
- package/config/devices/0x0129/yrd226-zw3.json +76 -0
- package/config/devices/0x012a/iq_dimmer.json +80 -0
- package/config/devices/0x012a/iq_outlet.json +76 -0
- package/config/devices/0x012a/qs9201-1208-840.json +12 -0
- package/config/devices/0x0138/smco400.json +61 -0
- package/config/devices/0x013c/pad15.json +12 -38
- package/config/devices/0x013c/pan30.json +160 -0
- package/config/devices/0x013c/pan34.json +124 -0
- package/config/devices/0x013c/pse04.json +162 -0
- package/config/devices/0x0140/sc428zw.json +177 -0
- package/config/devices/0x0149/wds2.json +34 -1
- package/config/devices/0x014a/tstat-tbz500.json +66 -61
- package/config/devices/0x014f/el-sc-100.json +4 -4
- package/config/devices/0x0156/m_n_kp01.json +108 -0
- package/config/devices/0x0159/zmnhhd.json +162 -69
- package/config/devices/0x0159/zmnkad1.json +204 -0
- package/config/devices/0x0189/117001.json +227 -0
- package/config/devices/0x0194/clr-c1-pnlx.json +28 -0
- package/config/devices/0x019a/11_01_022.json +30 -25
- package/config/devices/0x019a/11_02_022.json +320 -0
- package/config/devices/0x019a/11_04_21_22_28.json +210 -0
- package/config/devices/0x019b/z-ph_wall_controller.json +113 -0
- package/config/devices/0x019b/zm_thermostat_16.json +159 -0
- package/config/devices/0x021d/ml2.json +120 -0
- package/config/devices/0x0234/zdb5100.json +4 -0
- package/config/devices/0x0244/homey.json +2 -2
- package/config/devices/0x0258/nas-pd07u1.json +0 -1
- package/config/devices/0x0258/nas-wr01ze.json +7 -1
- package/config/devices/0x0258/neo-ds07z.json +156 -0
- package/config/devices/0x025b/ezlopl.json +28 -0
- package/config/devices/0x025b/ezlosecure.json +28 -0
- package/config/devices/0x027a/zen17.json +11 -0
- package/config/devices/0x027a/zen32.json +12 -1
- package/config/devices/0x027a/zen34.json +11 -4
- package/config/devices/0x027a/zen71.json +9 -2
- package/config/devices/0x027a/zen72.json +9 -2
- package/config/devices/0x027a/zen76.json +9 -2
- package/config/devices/0x027a/zen77.json +9 -2
- package/config/devices/0x027a/zse40.json +20 -2
- package/config/devices/0x027a/zse43.json +212 -0
- package/config/devices/0x027a/zse44.json +365 -0
- package/config/devices/0x028c/pwly-7828-a1.json +289 -0
- package/config/devices/0x0300/7aa-ss-ve-a0.json +117 -0
- package/config/devices/0x0300/7ba-kp-v-b-a0.json +105 -0
- package/config/devices/0x0300/7ca-ss-ve-a0.json +110 -0
- package/config/devices/0x0312/mp21zd.json +40 -122
- package/config/devices/0x0312/mp21zp.json +24 -48
- package/config/devices/0x0312/mp22z.json +62 -52
- package/config/devices/0x0312/mr40z.json +55 -0
- package/config/devices/0x0312/ms10z.json +45 -185
- package/config/devices/0x0312/ms11zs.json +107 -0
- package/config/devices/0x0312/ms12z.json +45 -185
- package/config/devices/0x0312/ms13z.json +61 -256
- package/config/devices/0x0312/mse30z.json +216 -0
- package/config/devices/0x0312/n4001.json +50 -0
- package/config/devices/0x0312/n4002.json +108 -0
- package/config/devices/0x0312/templates/minoston_template.json +276 -0
- package/config/devices/0x0312/zw1103.json +1 -1
- package/config/devices/0x0312/zw1105.json +1 -1
- package/config/devices/0x0312/zw1201.json +1 -1
- package/config/devices/0x0312/zw1204.json +1 -1
- package/config/devices/0x0312/zw15.json +1 -1
- package/config/devices/0x0312/zw31.json +1 -1
- package/config/devices/0x0312/zw31s.json +109 -0
- package/config/devices/0x0312/zw32.json +1 -1
- package/config/devices/0x0312/zw37.json +1 -1
- package/config/devices/0x0312/zw39.json +211 -1
- package/config/devices/0x0312/zw681.json +1 -1
- package/config/devices/0x0312/zw922.json +70 -0
- package/config/devices/0x0312/zw96.json +1 -1
- package/config/devices/0x0312/zw97.json +1 -1
- package/config/devices/0x031e/lzw30-sn.json +9 -2
- package/config/devices/0x031e/lzw31-sn.json +9 -2
- package/config/devices/0x0330/sr-zv9001t4-dim.json +4 -0
- package/config/devices/0x0330/sr-zv9021a.json +201 -0
- package/config/devices/0x0330/sr-zv9092a.json +423 -0
- package/config/devices/0x0344/he-tps01.json +6 -1
- package/config/devices/0x0344/he-tps02.json +12 -2
- package/config/devices/0x0344/he-tps03.json +18 -13
- package/config/devices/0x0344/he-tps04.json +24 -4
- package/config/devices/0x0344/he-tps05.json +31 -6
- package/config/devices/0x0344/templates/heltun_template.json +57 -0
- package/config/devices/0x0346/keypad_v2.json +7 -7
- package/config/devices/0x0346/motion_sensor_gen2.json +7 -3
- package/config/devices/0x0346/range_extender_gen2.json +6 -2
- package/config/devices/0x0346/ring_base_station.json +5 -5
- package/config/devices/0x0346/ring_outdoor_siren.json +5 -1
- package/config/devices/0x0367/svhszwb1.json +13 -6
- package/config/devices/0x0371/zwa022.json +175 -0
- package/config/devices/0x0371/zwa024.json +831 -0
- package/config/devices/0x0390/ah-hub3.json +28 -0
- package/config/devices/0x039a/INT-SMDWD-01.json +99 -0
- package/config/devices/0x041b/39455_zw4008.json +6 -22
- package/config/devices/0x0445/trf-zw10.json +28 -0
- package/config/devices/0x0447/sqr14101_z.json +2 -18
- package/config/devices/0x0447/sqr14102_z.json +52 -0
- package/config/devices/0x0447/sqr22101_z.json +2 -18
- package/config/devices/0x0447/sqr22102_z.json +74 -0
- package/config/devices/0x0447/sqr44101_z.json +2 -18
- package/config/devices/0x0447/sqr44102_z.json +52 -0
- package/config/devices/0x0447/sqr50101_z.json +44 -0
- package/config/devices/0x0447/sqr62101whz.json +1 -17
- package/config/devices/0x0447/sqr62102whz.json +52 -0
- package/config/devices/0x0447/templates/schneider_template.json +15 -0
- package/config/devices/0x044f/uvh1301.json +30 -0
- package/config/devices/0x0450/h3ps-wc1.json +28 -0
- package/config/devices/0x0452/u-bolt-pro-zwave.json +30 -0
- package/config/devices/0x0454/v11-n13.json +30 -0
- package/config/devices/0x0456/homee-005.json +28 -0
- package/config/devices/0x4118/tsm02.json +122 -0
- package/config/devices/templates/master_template.json +93 -5
- package/package.json +10 -10
- package/config/devices/0x0090/892.json +0 -170
- package/config/devices/0x019a/11_04_022.json +0 -230
- package/config/devices/0x0312/nzw39.json +0 -215
|
@@ -1,5 +1,5 @@
|
|
|
1
1
|
{
|
|
2
|
-
"manufacturer": "
|
|
2
|
+
"manufacturer": "Schlage",
|
|
3
3
|
"manufacturerId": "0x003b",
|
|
4
4
|
"label": "JBE109",
|
|
5
5
|
"description": "J-Series by Schlage Z-Wave Keypad Deadbolt",
|
|
@@ -7,7 +7,7 @@
|
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x0004",
|
|
9
9
|
"productId": "0x2109",
|
|
10
|
-
"zwaveAllianceId": 3925
|
|
10
|
+
"zwaveAllianceId": [3925, 4134]
|
|
11
11
|
}
|
|
12
12
|
],
|
|
13
13
|
"firmwareVersion": {
|
|
@@ -18,10 +18,9 @@
|
|
|
18
18
|
{
|
|
19
19
|
"#": "3",
|
|
20
20
|
"label": "Beeper",
|
|
21
|
-
"description": "Config enable snd ff else 00",
|
|
22
21
|
"valueSize": 1,
|
|
23
22
|
"minValue": 0,
|
|
24
|
-
"maxValue":
|
|
23
|
+
"maxValue": 255,
|
|
25
24
|
"defaultValue": 255,
|
|
26
25
|
"unsigned": true,
|
|
27
26
|
"allowManualEntry": false,
|
|
@@ -32,17 +31,16 @@
|
|
|
32
31
|
},
|
|
33
32
|
{
|
|
34
33
|
"label": "Enable beeper",
|
|
35
|
-
"value":
|
|
34
|
+
"value": 255
|
|
36
35
|
}
|
|
37
36
|
]
|
|
38
37
|
},
|
|
39
38
|
{
|
|
40
39
|
"#": "4",
|
|
41
|
-
"label": "
|
|
42
|
-
"description": "Config enable snd ff else 00",
|
|
40
|
+
"label": "Vacation Mode",
|
|
43
41
|
"valueSize": 1,
|
|
44
42
|
"minValue": 0,
|
|
45
|
-
"maxValue":
|
|
43
|
+
"maxValue": 255,
|
|
46
44
|
"defaultValue": 0,
|
|
47
45
|
"unsigned": true,
|
|
48
46
|
"allowManualEntry": false,
|
|
@@ -53,18 +51,17 @@
|
|
|
53
51
|
},
|
|
54
52
|
{
|
|
55
53
|
"label": "Enable vacation mode",
|
|
56
|
-
"value":
|
|
54
|
+
"value": 255
|
|
57
55
|
}
|
|
58
56
|
]
|
|
59
57
|
},
|
|
60
58
|
{
|
|
61
59
|
"#": "5",
|
|
62
|
-
"label": "
|
|
63
|
-
"description": "Config enable snd ff else 00",
|
|
60
|
+
"label": "Lock & Leave",
|
|
64
61
|
"valueSize": 1,
|
|
65
62
|
"minValue": 0,
|
|
66
|
-
"maxValue":
|
|
67
|
-
"defaultValue":
|
|
63
|
+
"maxValue": 255,
|
|
64
|
+
"defaultValue": 255,
|
|
68
65
|
"unsigned": true,
|
|
69
66
|
"allowManualEntry": false,
|
|
70
67
|
"options": [
|
|
@@ -74,47 +71,16 @@
|
|
|
74
71
|
},
|
|
75
72
|
{
|
|
76
73
|
"label": "Enable lock & leave",
|
|
77
|
-
"value":
|
|
78
|
-
}
|
|
79
|
-
]
|
|
80
|
-
},
|
|
81
|
-
{
|
|
82
|
-
"#": "6",
|
|
83
|
-
"label": "User_slot_bit_field",
|
|
84
|
-
"description": "Get user slot occupied",
|
|
85
|
-
"valueSize": 4,
|
|
86
|
-
"minValue": 1,
|
|
87
|
-
"maxValue": 4,
|
|
88
|
-
"defaultValue": 0,
|
|
89
|
-
"unsigned": true,
|
|
90
|
-
"readOnly": true,
|
|
91
|
-
"allowManualEntry": false,
|
|
92
|
-
"options": [
|
|
93
|
-
{
|
|
94
|
-
"label": "User slots 8 – 1 (msb – lsb) 8,7,6,5,4,3,2,1",
|
|
95
|
-
"value": 1
|
|
96
|
-
},
|
|
97
|
-
{
|
|
98
|
-
"label": "User slots 16 – 9 (msb – lsb) 16,15,14,13,12,11,10,9",
|
|
99
|
-
"value": 2
|
|
100
|
-
},
|
|
101
|
-
{
|
|
102
|
-
"label": "User slots 24 – 17 (msb – lsb) 24,23,22,21,20,19,18,17",
|
|
103
|
-
"value": 3
|
|
104
|
-
},
|
|
105
|
-
{
|
|
106
|
-
"label": "User slots 30 – 25 (msb – lsb) x,x,30,29,28,27,26,25",
|
|
107
|
-
"value": 4
|
|
74
|
+
"value": 255
|
|
108
75
|
}
|
|
109
76
|
]
|
|
110
77
|
},
|
|
111
78
|
{
|
|
112
79
|
"#": "15",
|
|
113
|
-
"label": "
|
|
114
|
-
"description": "Config enable snd ff else 00",
|
|
80
|
+
"label": "Auto Lock",
|
|
115
81
|
"valueSize": 1,
|
|
116
82
|
"minValue": 0,
|
|
117
|
-
"maxValue":
|
|
83
|
+
"maxValue": 255,
|
|
118
84
|
"defaultValue": 0,
|
|
119
85
|
"unsigned": true,
|
|
120
86
|
"allowManualEntry": false,
|
|
@@ -125,7 +91,7 @@
|
|
|
125
91
|
},
|
|
126
92
|
{
|
|
127
93
|
"label": "Enable auto lock",
|
|
128
|
-
"value":
|
|
94
|
+
"value": 255
|
|
129
95
|
}
|
|
130
96
|
]
|
|
131
97
|
},
|
|
@@ -137,12 +103,23 @@
|
|
|
137
103
|
"maxValue": 8,
|
|
138
104
|
"defaultValue": 4,
|
|
139
105
|
"unsigned": true
|
|
106
|
+
},
|
|
107
|
+
{
|
|
108
|
+
"#": "6",
|
|
109
|
+
"label": "User Slots",
|
|
110
|
+
"description": "This value represents a bitmask with 30 bits. Each bit represents a user slot. A value of 1 means that the slot is occupied.",
|
|
111
|
+
"valueSize": 4,
|
|
112
|
+
"minValue": 0,
|
|
113
|
+
"maxValue": 1073741823,
|
|
114
|
+
"defaultValue": 0,
|
|
115
|
+
"unsigned": true,
|
|
116
|
+
"readOnly": true
|
|
140
117
|
}
|
|
141
118
|
],
|
|
142
119
|
"metadata": {
|
|
143
|
-
"inclusion": "One-button Add lock to Z-Wave Network (Inclusion)
|
|
144
|
-
"exclusion": "One-button Remove lock from Z-Wave Network (Exclusion)
|
|
145
|
-
"reset": "1. Press and hold the enrollment button
|
|
146
|
-
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/
|
|
120
|
+
"inclusion": "One-button Add lock to Z-Wave Network (Inclusion) 1. Place your home automation system or panel into the “Add” or Inclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). 2. Remove the battery cover of the deadbolt. 3. Press then release the button on the PCB. 4. An LED will flash amber indicating the “Add” or Inclusion process is in progress. • If the Security Scheme is Security 2 (S2), verify the DSK of the lock at the Z-Wave Controller. The PIN Code portion of the Z-Wave DSK will be needed. 5. When a green LED turns ON, the “Add” or Inclusion has completed successfully. 6. If a red LED turns ON, try repeating steps 1-3 Interactive Instruction for Add https://instructions.allegion.com/instr/86/2543",
|
|
121
|
+
"exclusion": "One-button Remove lock from Z-Wave Network (Exclusion) 1. Place your home automation system or panel into the “Remove” or Exclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). 2. Remove the battery cover of the deadbolt. 3. Press then release the button on the PCB. 4. An LED will flash amber indicating the “Remove” or Exclusion process is in progress. 5. When a green LED flashes 3 times, the “Remove” or Exclusion process is completed successfully. 6. If a red LED turns ON, try repeating steps 1-3 Interactive Instruction for Remove https://instructions.allegion.com/instr/86/258",
|
|
122
|
+
"reset": "1. Press and hold the enrollment button. The led will light solid amber. 2. After about 8 seconds of holding the button, the amber light will turn off. Release the button. Successful FDR is indicated by 3 long green blinks and 3 long beeps. 3. You must enter a valid user code. Lock will enter auto-handing routine, locking and unlocking several times. Auto-handing is complete when lock movement stops",
|
|
123
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4134/J-Series%20UG-f1.pdf"
|
|
147
124
|
}
|
|
148
125
|
}
|
|
@@ -0,0 +1,133 @@
|
|
|
1
|
+
{
|
|
2
|
+
"manufacturer": "Schlage",
|
|
3
|
+
"manufacturerId": "0x003b",
|
|
4
|
+
"label": "JFE109",
|
|
5
|
+
"description": "Keypad Lever",
|
|
6
|
+
"devices": [
|
|
7
|
+
{
|
|
8
|
+
"productType": "0x0004",
|
|
9
|
+
"productId": "0x6109",
|
|
10
|
+
"zwaveAllianceId": 4136
|
|
11
|
+
}
|
|
12
|
+
],
|
|
13
|
+
"firmwareVersion": {
|
|
14
|
+
"min": "0.0",
|
|
15
|
+
"max": "255.255"
|
|
16
|
+
},
|
|
17
|
+
"associations": {
|
|
18
|
+
"1": {
|
|
19
|
+
"label": "Lifeline",
|
|
20
|
+
"maxNodes": 2,
|
|
21
|
+
"isLifeline": true
|
|
22
|
+
}
|
|
23
|
+
},
|
|
24
|
+
"paramInformation": [
|
|
25
|
+
{
|
|
26
|
+
"#": "15",
|
|
27
|
+
"label": "Auto Lock",
|
|
28
|
+
"valueSize": 1,
|
|
29
|
+
"minValue": 0,
|
|
30
|
+
"maxValue": 255,
|
|
31
|
+
"defaultValue": 255,
|
|
32
|
+
"unsigned": true,
|
|
33
|
+
"readOnly": true,
|
|
34
|
+
"options": [
|
|
35
|
+
{
|
|
36
|
+
"label": "Disable",
|
|
37
|
+
"value": 0
|
|
38
|
+
},
|
|
39
|
+
{
|
|
40
|
+
"label": "Enable",
|
|
41
|
+
"value": 255
|
|
42
|
+
}
|
|
43
|
+
]
|
|
44
|
+
},
|
|
45
|
+
{
|
|
46
|
+
"#": "16",
|
|
47
|
+
"label": "User Code PIN Length",
|
|
48
|
+
"valueSize": 1,
|
|
49
|
+
"unit": "digits",
|
|
50
|
+
"minValue": 4,
|
|
51
|
+
"maxValue": 8,
|
|
52
|
+
"defaultValue": 4,
|
|
53
|
+
"unsigned": true
|
|
54
|
+
},
|
|
55
|
+
{
|
|
56
|
+
"#": "3",
|
|
57
|
+
"label": "Beeper",
|
|
58
|
+
"valueSize": 1,
|
|
59
|
+
"minValue": 0,
|
|
60
|
+
"maxValue": 255,
|
|
61
|
+
"defaultValue": 255,
|
|
62
|
+
"unsigned": true,
|
|
63
|
+
"allowManualEntry": false,
|
|
64
|
+
"options": [
|
|
65
|
+
{
|
|
66
|
+
"label": "Disable",
|
|
67
|
+
"value": 0
|
|
68
|
+
},
|
|
69
|
+
{
|
|
70
|
+
"label": "Enable",
|
|
71
|
+
"value": 255
|
|
72
|
+
}
|
|
73
|
+
]
|
|
74
|
+
},
|
|
75
|
+
{
|
|
76
|
+
"#": "4",
|
|
77
|
+
"label": "Vacation Mode",
|
|
78
|
+
"valueSize": 1,
|
|
79
|
+
"minValue": 0,
|
|
80
|
+
"maxValue": 255,
|
|
81
|
+
"defaultValue": 0,
|
|
82
|
+
"unsigned": true,
|
|
83
|
+
"allowManualEntry": false,
|
|
84
|
+
"options": [
|
|
85
|
+
{
|
|
86
|
+
"label": "Disable",
|
|
87
|
+
"value": 0
|
|
88
|
+
},
|
|
89
|
+
{
|
|
90
|
+
"label": "Enable",
|
|
91
|
+
"value": 255
|
|
92
|
+
}
|
|
93
|
+
]
|
|
94
|
+
},
|
|
95
|
+
{
|
|
96
|
+
"#": "5",
|
|
97
|
+
"label": "Lock & Leave",
|
|
98
|
+
"valueSize": 1,
|
|
99
|
+
"minValue": 0,
|
|
100
|
+
"maxValue": 255,
|
|
101
|
+
"defaultValue": 0,
|
|
102
|
+
"unsigned": true,
|
|
103
|
+
"readOnly": true,
|
|
104
|
+
"options": [
|
|
105
|
+
{
|
|
106
|
+
"label": "Disable",
|
|
107
|
+
"value": 0
|
|
108
|
+
},
|
|
109
|
+
{
|
|
110
|
+
"label": "Enable",
|
|
111
|
+
"value": 255
|
|
112
|
+
}
|
|
113
|
+
]
|
|
114
|
+
},
|
|
115
|
+
{
|
|
116
|
+
"#": "6",
|
|
117
|
+
"label": "User Slot Status",
|
|
118
|
+
"description": "This value represents a bitmask with 30 bits. Each bit represents a user slot. A value of 1 means that the slot is occupied.",
|
|
119
|
+
"valueSize": 4,
|
|
120
|
+
"minValue": 0,
|
|
121
|
+
"maxValue": 1073741823,
|
|
122
|
+
"defaultValue": 0,
|
|
123
|
+
"unsigned": true,
|
|
124
|
+
"readOnly": true
|
|
125
|
+
}
|
|
126
|
+
],
|
|
127
|
+
"metadata": {
|
|
128
|
+
"inclusion": "One-button Add lock to Z-Wave Network (Inclusion) 1. Place your home automation system or panel into the “Add” or Inclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). 2. Remove the battery cover of the deadbolt. 3. Press then release the button on the PCB. 4. An LED will flash amber indicating the “Add” or Inclusion process is in progress. • If the Security Scheme is Security 2 (S2), verify the DSK of the lock at the Z-Wave Controller. The PIN Code portion of the Z-Wave DSK will be needed. 5. When a green LED turns ON, the “Add” or Inclusion has completed successfully. 6. If a red LED turns ON, try repeating steps 1-3 Interactive Instruction for Add https://instructions.allegion.com/instr/86/2543",
|
|
129
|
+
"exclusion": "One-button Remove lock from Z-Wave Network (Exclusion) 1. Place your home automation system or panel into the “Remove” or Exclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). 2. Remove the battery cover of the deadbolt. 3. Press then release the button on the PCB. 4. An LED will flash amber indicating the “Remove” or Exclusion process is in progress. 5. When a green LED flashes 3 times, the “Remove” or Exclusion process is completed successfully. 6. If a red LED turns ON, try repeating steps 1-3 Interactive Instruction for Remove https://instructions.allegion.com/instr/86/2581",
|
|
130
|
+
"reset": "1. Press and hold the enrollment button. The led will light solid amber. 2. After about 8 seconds of holding the button, the amber light will turn off. Release the button. Successful FDR is indicated by 3 long green blinks and 3 long beeps. 3. You must enter a valid user code. Lock will enter auto-handing routine, locking and unlocking several times. Auto-handing is complete when lock movement stops",
|
|
131
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4136/J-Series%20UG-e.pdf"
|
|
132
|
+
}
|
|
133
|
+
}
|
|
@@ -1,13 +1,13 @@
|
|
|
1
1
|
{
|
|
2
|
-
"manufacturer": "
|
|
2
|
+
"manufacturer": "Schlage",
|
|
3
3
|
"manufacturerId": "0x003b",
|
|
4
4
|
"label": "S-6500F",
|
|
5
|
-
"description": "
|
|
5
|
+
"description": "Z-Wave Mortise Lock",
|
|
6
6
|
"devices": [
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x0003",
|
|
9
9
|
"productId": "0x6500",
|
|
10
|
-
"zwaveAllianceId": [3690, 3811, 3813]
|
|
10
|
+
"zwaveAllianceId": [3690, 3811, 3813, 4122, 4181, 4182]
|
|
11
11
|
}
|
|
12
12
|
],
|
|
13
13
|
"firmwareVersion": {
|
|
@@ -57,29 +57,29 @@
|
|
|
57
57
|
},
|
|
58
58
|
{
|
|
59
59
|
"#": "6",
|
|
60
|
-
"label": "User
|
|
61
|
-
"description": "Each bit
|
|
60
|
+
"label": "User Slots",
|
|
61
|
+
"description": "This value represents a bitmask with 10 bits. Each bit represents a user slot. A value of 1 means that the slot is occupied.",
|
|
62
62
|
"valueSize": 2,
|
|
63
63
|
"minValue": 0,
|
|
64
|
-
"maxValue":
|
|
64
|
+
"maxValue": 1023,
|
|
65
65
|
"defaultValue": 3,
|
|
66
66
|
"unsigned": true
|
|
67
67
|
},
|
|
68
68
|
{
|
|
69
69
|
"#": "18",
|
|
70
|
-
"label": "
|
|
71
|
-
"description": "Version of the bootloader",
|
|
70
|
+
"label": "Bootloader Version",
|
|
72
71
|
"valueSize": 1,
|
|
73
72
|
"minValue": 0,
|
|
74
|
-
"maxValue":
|
|
73
|
+
"maxValue": 255,
|
|
75
74
|
"defaultValue": 1,
|
|
75
|
+
"readOnly": true,
|
|
76
76
|
"unsigned": true
|
|
77
77
|
}
|
|
78
78
|
],
|
|
79
79
|
"metadata": {
|
|
80
|
-
"inclusion": "1. Place your Z-Wave Controller into the “Add” or Inclusion Mode (Refer the respective documentation for that specific home automation system or panel device for details)
|
|
81
|
-
"exclusion": "1. Place your Z-Wave Controller into the “Remove” or Exclusion Mode (Refer the respective documentation for that specific home automation system or panel device for details)
|
|
82
|
-
"reset": "Please use this procedure only when the network primary controller is missing or otherwise inoperable
|
|
83
|
-
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/
|
|
80
|
+
"inclusion": "1. Place your Z-Wave Controller into the “Add” or Inclusion Mode (Refer the respective documentation for that specific home automation system or panel device for details).\n2. Slide the battery cover upward.\n3. Press the wireless button more than 3 seconds.\n4. Press “1” on the keypad.\n5. Press “6” on the keypad.\n6. Press User Code on the keypad.\n7. Press “#” on the keypad.\n8. If RF LED flickers, inclusion has completed successfully.\n9. If battery replace LED flickers(fail), try repeating steps 1-7",
|
|
81
|
+
"exclusion": "1. Place your Z-Wave Controller into the “Remove” or Exclusion Mode (Refer the respective documentation for that specific home automation system or panel device for details).\n2. Slide the battery cover upward.\n3. Press the wireless button more than 3 seconds.\n4. Press “2” on the keypad.\n5. Press “6” on the keypad.\n6. Press User Code on the keypad.\n7. Press “#” on the keypad.\n8. If RF LED flickers, exclusion has completed successfully.\n9. If battery replace LED flickers, try repeating steps 1-7",
|
|
82
|
+
"reset": "Please use this procedure only when the network primary controller is missing or otherwise inoperable.\nWhen Master code was already registered\n1. Remove batteries (power off).\n2. Press “N” and “S” buttons at the same time and hold.\n3. Insert batteries (power on).\n4. Release “N” and “S” buttons.\n5. Press 3-digit Master code.\n6. Press “#” on the keypad.\n7. Press “8” on the keypad.\nWhen Master code was not registered yet\n1. Remove batteries (power off).\n2. Press “N” button and “S” button at the same time and hold.\n3. Insert batteries (power on).\n4. Release “N” and “S” buttons.\n5. Press 3-digit Master code to register.\n6. Press “#” on the keypad.\n7. Press previous 3-digit Master code.\n8. Press “#” on the keypad",
|
|
83
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4122/Manual%20for%20Schlage%20Z-Wave%20Mortise%20Lock%20v1.1.pdf"
|
|
84
84
|
}
|
|
85
85
|
}
|
|
@@ -0,0 +1,17 @@
|
|
|
1
|
+
{
|
|
2
|
+
"manufacturer": "Everspring",
|
|
3
|
+
"manufacturerId": "0x0060",
|
|
4
|
+
"label": "AN301",
|
|
5
|
+
"description": "274",
|
|
6
|
+
"devices": [
|
|
7
|
+
{
|
|
8
|
+
"productType": "0x0000",
|
|
9
|
+
"productId": "0x0004",
|
|
10
|
+
"zwaveAllianceId": 4317
|
|
11
|
+
}
|
|
12
|
+
],
|
|
13
|
+
"firmwareVersion": {
|
|
14
|
+
"min": "0.0",
|
|
15
|
+
"max": "255.255"
|
|
16
|
+
}
|
|
17
|
+
}
|
|
@@ -7,7 +7,7 @@
|
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x4952",
|
|
9
9
|
"productId": "0x3237",
|
|
10
|
-
"zwaveAllianceId": 4004
|
|
10
|
+
"zwaveAllianceId": [4004, 4168]
|
|
11
11
|
}
|
|
12
12
|
],
|
|
13
13
|
"firmwareVersion": {
|
|
@@ -89,6 +89,6 @@
|
|
|
89
89
|
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.\n2. Once the controller is ready to add your device, press and release the top or bottom of the smart switch (rocker)",
|
|
90
90
|
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.\n2. Once the controller is ready to remove your device, press and release the top or bottom of the smart switch rocker)",
|
|
91
91
|
"reset": "Quickly press ON (top) button three times, then, immediately press the OFF (bottom) button three times. The LED will flash ON/OFF five times when completed successfully",
|
|
92
|
-
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/
|
|
92
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4168/39348%20QSG%20v3.pdf"
|
|
93
93
|
}
|
|
94
94
|
}
|
|
@@ -7,7 +7,7 @@
|
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x4952",
|
|
9
9
|
"productId": "0x3238",
|
|
10
|
-
"zwaveAllianceId": 4006
|
|
10
|
+
"zwaveAllianceId": [4006, 4171]
|
|
11
11
|
}
|
|
12
12
|
],
|
|
13
13
|
"firmwareVersion": {
|
|
@@ -89,6 +89,6 @@
|
|
|
89
89
|
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.\n2. Once the controller is ready to add your device, press up on the toggle",
|
|
90
90
|
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.\n2. Once the controller is ready to remove your device, press up on the toggle",
|
|
91
91
|
"reset": "Quickly press up three times, then, immediately press down three times",
|
|
92
|
-
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/
|
|
92
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4171/39354%20QSG%20v3.pdf"
|
|
93
93
|
}
|
|
94
94
|
}
|
|
@@ -7,7 +7,7 @@
|
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x4952",
|
|
9
9
|
"productId": "0x3139",
|
|
10
|
-
"zwaveAllianceId": 3349
|
|
10
|
+
"zwaveAllianceId": [3349, 4156]
|
|
11
11
|
}
|
|
12
12
|
],
|
|
13
13
|
"firmwareVersion": {
|
|
@@ -86,9 +86,9 @@
|
|
|
86
86
|
"treatBasicSetAsEvent": true
|
|
87
87
|
},
|
|
88
88
|
"metadata": {
|
|
89
|
-
"inclusion": "1. Follow the instructions for your Z-Wave certified
|
|
90
|
-
"exclusion": "1. Follow the instructions for your Z-Wave certified controller
|
|
91
|
-
"reset": "1. Quickly press ON (top) button three times then immediately
|
|
92
|
-
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=
|
|
89
|
+
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.\n2. Once the controller is ready to add your device, press and release the top or bottom of the wireless smart switch (rocker)",
|
|
90
|
+
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.\n2. Once the controller is ready to remove your device, press and release the top or bottom of the wireless smart switch (rocker)",
|
|
91
|
+
"reset": "1. Quickly press ON (top) button three times then immediately press the OFF (Bottom) button three times. The LED will flash ON/OFF five times when completed successfully. Note: This should only be used if your network’s primary controller is missing or otherwise inoperable",
|
|
92
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4156/43072%20QSG%20v4.pdf"
|
|
93
93
|
}
|
|
94
94
|
}
|
|
@@ -7,7 +7,7 @@
|
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x4952",
|
|
9
9
|
"productId": "0x3231",
|
|
10
|
-
"zwaveAllianceId": 3351
|
|
10
|
+
"zwaveAllianceId": [3351, 4167]
|
|
11
11
|
}
|
|
12
12
|
],
|
|
13
13
|
"firmwareVersion": {
|
|
@@ -86,9 +86,9 @@
|
|
|
86
86
|
"treatBasicSetAsEvent": true
|
|
87
87
|
},
|
|
88
88
|
"metadata": {
|
|
89
|
-
"inclusion": "1. Follow the instructions for your Z-Wave certified
|
|
90
|
-
"exclusion": "1. Follow the instructions for your Z-Wave certified controller
|
|
91
|
-
"reset": "1. Quickly press ON (top) button three times then immediately
|
|
92
|
-
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=
|
|
89
|
+
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.\n2. Once the controller is ready to add your device, press and release the top or bottom of the wireless smart switch (rocker)",
|
|
90
|
+
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.\n2. Once the controller is ready to remove your device, press and release the top or bottom of the wireless smart switch (rocker)",
|
|
91
|
+
"reset": "1. Quickly press ON (top) button three times then immediately press the OFF (Bottom) button three times. The LED will flash ON/OFF five times when completed successfully. Note: This should only be used if your network’s primary controller is missing or otherwise inoperable",
|
|
92
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4167/43074%20QSG%20v1.pdf"
|
|
93
93
|
}
|
|
94
94
|
}
|
|
@@ -7,7 +7,7 @@
|
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x4944",
|
|
9
9
|
"productId": "0x3330",
|
|
10
|
-
"zwaveAllianceId": 4002
|
|
10
|
+
"zwaveAllianceId": [4002, 4162]
|
|
11
11
|
}
|
|
12
12
|
],
|
|
13
13
|
"firmwareVersion": {
|
|
@@ -151,6 +151,6 @@
|
|
|
151
151
|
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.\n2. Once the controller is ready to add your device, press up and release the top or bottom of the rocker.\n3. The controller’s app will indicate if it has discovered the switch. If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the side of the box or the QR code label on the product (see Figure 1). Enter the 5-digit code",
|
|
152
152
|
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.\n2. Once the controller is ready to remove your device, press up and release the toggle",
|
|
153
153
|
"reset": "Quickly press ON (up) button three times then immediately press the OFF (down) button three times",
|
|
154
|
-
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/
|
|
154
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4162/43105%20QSG%20v1.pdf"
|
|
155
155
|
}
|
|
156
156
|
}
|
|
@@ -7,7 +7,7 @@
|
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x4944",
|
|
9
9
|
"productId": "0x3332",
|
|
10
|
-
"zwaveAllianceId": [4003, 4034]
|
|
10
|
+
"zwaveAllianceId": [4003, 4034, 4163]
|
|
11
11
|
}
|
|
12
12
|
],
|
|
13
13
|
"firmwareVersion": {
|
|
@@ -161,6 +161,6 @@
|
|
|
161
161
|
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.\n2. Once the controller is ready to add your device, press up and release the toggle.\n3. The controller’s app will indicate if it discovers the switch. If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the side of the box or the QR code label on the product (see Figure 1). Enter the 5-digit code",
|
|
162
162
|
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.\n2. Once the controller is ready to remove your device, press up and release the toggle",
|
|
163
163
|
"reset": "Quickly press ON (up) button three times then immediately press the OFF (down) button three times.",
|
|
164
|
-
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/
|
|
164
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4163/43107%20QSG%20v1.pdf"
|
|
165
165
|
}
|
|
166
166
|
}
|
|
@@ -1,12 +1,13 @@
|
|
|
1
1
|
{
|
|
2
2
|
"manufacturer": "GE/Jasco",
|
|
3
3
|
"manufacturerId": "0x0063",
|
|
4
|
-
"label": "46201",
|
|
4
|
+
"label": "46201 / ZW4008",
|
|
5
5
|
"description": "GE Quick-fit Smart In-Wall Paddle Switch",
|
|
6
6
|
"devices": [
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x4952",
|
|
9
|
-
"productId": "0x3135"
|
|
9
|
+
"productId": "0x3135",
|
|
10
|
+
"zwaveAllianceId": 4143
|
|
10
11
|
}
|
|
11
12
|
],
|
|
12
13
|
"firmwareVersion": {
|
|
@@ -1,12 +1,13 @@
|
|
|
1
1
|
{
|
|
2
2
|
"manufacturer": "GE/Jasco",
|
|
3
3
|
"manufacturerId": "0x0063",
|
|
4
|
-
"label": "46202",
|
|
4
|
+
"label": "46202 / ZW4009",
|
|
5
5
|
"description": "GE Enbrighten Z-Wave Plus Smart Switch",
|
|
6
6
|
"devices": [
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x4952",
|
|
9
|
-
"productId": "0x3137"
|
|
9
|
+
"productId": "0x3137",
|
|
10
|
+
"zwaveAllianceId": 4157
|
|
10
11
|
}
|
|
11
12
|
],
|
|
12
13
|
"firmwareVersion": {
|
|
@@ -76,6 +77,26 @@
|
|
|
76
77
|
"value": 1
|
|
77
78
|
}
|
|
78
79
|
]
|
|
80
|
+
},
|
|
81
|
+
{
|
|
82
|
+
"#": "19",
|
|
83
|
+
"label": "Alternate Exclusion",
|
|
84
|
+
"valueSize": 1,
|
|
85
|
+
"minValue": 0,
|
|
86
|
+
"maxValue": 1,
|
|
87
|
+
"defaultValue": 0,
|
|
88
|
+
"unsigned": true,
|
|
89
|
+
"allowManualEntry": false,
|
|
90
|
+
"options": [
|
|
91
|
+
{
|
|
92
|
+
"label": "Normal operation",
|
|
93
|
+
"value": 0
|
|
94
|
+
},
|
|
95
|
+
{
|
|
96
|
+
"label": "Press two times on button and two time off button, LED will flash 5 times if successful",
|
|
97
|
+
"value": 1
|
|
98
|
+
}
|
|
99
|
+
]
|
|
79
100
|
}
|
|
80
101
|
],
|
|
81
102
|
"compat": {
|
|
@@ -7,7 +7,7 @@
|
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x4952",
|
|
9
9
|
"productId": "0x3136",
|
|
10
|
-
"zwaveAllianceId": 3357
|
|
10
|
+
"zwaveAllianceId": [3357, 4142]
|
|
11
11
|
}
|
|
12
12
|
],
|
|
13
13
|
"firmwareVersion": {
|
|
@@ -89,6 +89,6 @@
|
|
|
89
89
|
"inclusion": "1. Follow the instructions for your Z-Wave certified\ncontroller to add a device to the Z-Wave network.\n2. Once the controller is ready to add your device, press and\nrelease the top or bottom of the wireless smart switch (rocker)",
|
|
90
90
|
"exclusion": "1. Follow the instructions for your Z-Wave certified controller\nto remove a device from the Z-Wave network.\n2. Once the controller is ready to remove your device, press and\nrelease the top or bottom of the wireless smart switch (rocker)",
|
|
91
91
|
"reset": "1. Quickly press ON (top) button three times then immediately\npress the OFF (Bottom) button three times. The LED will\nflash ON/OFF five times when completed successfully.\nNote: This should only be used if your network’s primary\ncontroller is missing or otherwise inoperable",
|
|
92
|
-
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=
|
|
92
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4142/46562%20EnFrSp%20QSG%20v3.pdf"
|
|
93
93
|
}
|
|
94
94
|
}
|
|
@@ -7,13 +7,20 @@
|
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x4c42",
|
|
9
9
|
"productId": "0x3035",
|
|
10
|
-
"zwaveAllianceId": 3924
|
|
10
|
+
"zwaveAllianceId": [3924, 4105, 4145]
|
|
11
11
|
}
|
|
12
12
|
],
|
|
13
13
|
"firmwareVersion": {
|
|
14
14
|
"min": "0.0",
|
|
15
15
|
"max": "255.255"
|
|
16
16
|
},
|
|
17
|
+
"associations": {
|
|
18
|
+
"1": {
|
|
19
|
+
"label": "Lifeline",
|
|
20
|
+
"maxNodes": 5,
|
|
21
|
+
"isLifeline": true
|
|
22
|
+
}
|
|
23
|
+
},
|
|
17
24
|
"paramInformation": [
|
|
18
25
|
{
|
|
19
26
|
"#": "1",
|
|
@@ -60,9 +67,9 @@
|
|
|
60
67
|
}
|
|
61
68
|
],
|
|
62
69
|
"metadata": {
|
|
63
|
-
"inclusion": "
|
|
64
|
-
"exclusion": "
|
|
65
|
-
"reset": "
|
|
66
|
-
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/
|
|
70
|
+
"inclusion": "Adding your device to a Z-Wave network\n1. When initially powered, the bulb is in SmartStart inclusion mode. If your hub supports SmartStart, scan the\nQR code.\n2. To change to classic inclusion mode, turn bulb OFF, then ON three times. The bulb rapidly flashes four\ntimes to indicate classic mode.\n3. To change back to SmartStart inclusion mode, turn the bulb OFF, then ON three times. The bulb rapidly\nflashes six times to indicate SmartStart mode.\nNOTE: The bulb attempts to connect in either inclusion mode for 10 seconds. If not found after 10 seconds,\ncycle the bulb OFF/ON to restart the inclusion mode.\n4. In either method, the bulb flashes twice to indicate it was added to the network.\nNOTE: The bulb remains in the last known inclusion mode when cycled OFF/ON once.\nYou have complete control to turn your light ON/OFF or set dim levels according to groups, scenes, schedules\nand interactive automations programmed by your controller.\nIf your Z-Wave certified controller features remote access, you can control your lighting from your mobile\ndevices.\nIf prompted by the controller to enter the S2 security code, refer to the QR code/security number on the side\nof the box or the QR code label on the product (see Figure 1). Enter the 5-digit pin code.\nFigure 1.\nNOTE: SmartStart enabled products can be added into a Z-Wave network by scanning the QR code on the\nproduct with a controller providing SmartStart inclusion. No further action is required and the SmartStart\nproduct will be added automatically within 10 minutes of being switched on in the network vicinity",
|
|
71
|
+
"exclusion": "To remove and reset the device\n1. Follow the instructions for your Z-Wave certified controller\nto remove a device from the Z-Wave network.\n2. Once the controller is ready to remove your device, turn\nbulb OFF, then ON three times. The smart bulb flashes\ntwice when removed from the network",
|
|
72
|
+
"reset": "To return your smart bulb to factory defaults\nStarting with the bulb on, cycle the wall switch OFF/ON\nfour times.\n1. Turn the switch off, pause one second, then turn back ON.\n2. Repeat three times (four times total).\n3. The smart bulb flashes twice when reset.\nNOTE: This should only be used in the event your network’s\nprimary controller is missing or otherwise inoperable",
|
|
73
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4145/52190-2.pdf"
|
|
67
74
|
}
|
|
68
75
|
}
|