urbanopt-cli 0.4.1 → 0.6.1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/.gitignore +3 -1
- data/CHANGELOG.md +59 -0
- data/CMakeLists.txt +17 -17
- data/FindOpenStudioSDK.cmake +12 -7
- data/Gemfile +8 -10
- data/LICENSE.md +11 -1
- data/README.md +1 -0
- data/Rakefile +16 -6
- data/example_files/Gemfile +25 -9
- data/example_files/example_project.json +35 -20
- data/example_files/example_project_combined.json +100 -5
- data/example_files/example_project_with_electric_network.json +2116 -0
- data/example_files/mappers/Baseline.rb +111 -51
- data/example_files/mappers/CreateBar.rb +19 -7
- data/example_files/mappers/EvCharging.rb +141 -0
- data/example_files/mappers/Floorspace.rb +29 -17
- data/example_files/mappers/HighEfficiency.rb +20 -8
- data/example_files/mappers/HighEfficiencyCreateBar.rb +19 -8
- data/example_files/mappers/HighEfficiencyFloorspace.rb +19 -8
- data/example_files/mappers/ThermalStorage.rb +16 -6
- data/example_files/mappers/base_workflow.osw +26 -1
- data/example_files/mappers/floorspace_workflow.osw +9 -0
- data/example_files/measures/BuildResidentialModel/measure.rb +249 -134
- data/example_files/reopt/base_assumptions.json +2 -2
- data/example_files/reopt/multiPV_assumptions.json +4 -3
- data/example_files/residential/clothes_dryer.tsv +7 -7
- data/example_files/residential/clothes_washer.tsv +2 -2
- data/example_files/residential/cooling_system.tsv +42 -22
- data/example_files/residential/dishwasher.tsv +1 -1
- data/example_files/residential/exhaust.tsv +3 -0
- data/example_files/residential/heat_pump.tsv +62 -40
- data/example_files/residential/water_heater.tsv +1 -1
- data/example_files/resources/hpxml-measures/.github/pull_request_template.md +14 -0
- data/example_files/resources/hpxml-measures/.github/workflows/config.yml +116 -0
- data/example_files/resources/hpxml-measures/.gitignore +1 -8
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.rb +1088 -1329
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.xml +1819 -1383
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/constants.rb +0 -8
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/geometry.rb +450 -362
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules.rb +165 -112
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_config.json +388 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_config.md +43 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_weekday_state_and_monthly_schedule_shift.csv +613 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_weekend_state_and_monthly_schedule_shift.csv +613 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-coal.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-appliances-dehumidifier-ief.osw → base-appliances-dehumidifier-ief-portable.osw} +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-appliances-dehumidifier-50percent.osw → base-appliances-dehumidifier-ief-whole-home.osw} +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-dehumidifier.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-modified.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-none.osw +61 -87
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-oil.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-propane.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-wood.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-flat.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-radiant-barrier.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-unvented-insulated-roof.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-vented.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-boiler-only-baseboard.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-boiler-only-fan-coil.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-mechvent-shared-preconditioning.osw → base-bldgtype-multifamily-shared-mechvent-preconditioning.osw} +70 -95
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-mechvent-shared.osw → base-bldgtype-multifamily-shared-mechvent.osw} +70 -95
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-pv.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-water-heater.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-single-family-attached.osw → base-bldgtype-single-family-attached.osw} +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-combi-tankless-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-combi-tankless.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-dwhr.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-standbyloss.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-with-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-electric.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-hpwh.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-indirect.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-low-flow-fixtures.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-none.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-demand.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-manual.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-nocontrol.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-temperature.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-timer.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-evacuated-tube.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-flat-plate.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-ics.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-indirect-flat-plate.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-thermosyphon-flat-plate.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-coal.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-elec-uef.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas-uef.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-uef.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-with-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-with-solar.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-oil.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-wood.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric-outside.osw +56 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric-uef.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-uef.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-with-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-with-solar.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-propane.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-2stories-garage.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-2stories.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-1.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-2.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-4.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-5.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-garage.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-ach-house-pressure.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-cfm-house-pressure.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-cfm50.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-flue.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-natural-ach.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-overhangs.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-windows-none.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-ambient.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-conditioned-basement-slab-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-slab.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement-assembly-r.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement-wall-insulation.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unvented-crawlspace.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-vented-crawlspace.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed-cooling-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed-heating-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-2-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-var-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-coal-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-elec-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-gas-central-ac-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-gas-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-oil-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-propane-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-wood-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-2-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-var-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-plus-air-to-air-heat-pump-heating.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-electric.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-2-speed.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-var-speed.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-mini-split-heat-pump-ducted.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ducts-leakage-percent.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-elec-resistance-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-furnace-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-only-ducted.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-fireplace-wood-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-fixed-heater-gas-only.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-floor-furnace-propane-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-coal-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-elec-central-ac-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-elec-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-central-ac-2-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-central-ac-var-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-room-ac.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-oil-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-propane-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-wood-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump-cooling-only.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump-heating-only.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump.osw +56 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-airflow-defect-furnace-gas-central-ac-1-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-1-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-2-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-var-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-1-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-2-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-var-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-only.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-ground-to-air-heat-pump.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-mini-split-air-conditioner-only-ducted.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-mini-split-heat-pump-ducted.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-charge-defect-furnace-gas-central-ac-1-speed.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-none-furnace-gas-central-ac-1-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-air-conditioner-only-ducted.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-air-conditioner-only-ductless.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted-cooling-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted-heating-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ductless.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-none.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-portable-heater-gas-only.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-programmable-thermostat-detailed.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-room-ac-only-33percent.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-room-ac-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-setpoints.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-stove-oil-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-stove-wood-pellets-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-undersized.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-wall-furnace-elec-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-lighting-ceiling-fans.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-lighting-detailed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-AMY-2012.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-baltimore-md.osw +64 -90
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-dallas-tx.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-duluth-mn.osw +69 -95
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-helena-mt.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-honolulu-hi.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-miami-fl.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-phoenix-az.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-portland-or.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-balanced.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-bath-kitchen-fans.osw +64 -92
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-cfis-evap-cooler-only-ducted.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-cfis.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-erv-atre-asre.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-erv.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-exhaust-rated-flow-rate.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-exhaust.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-hrv-asre.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-hrv.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-supply.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-whole-house-fan.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-defaults.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-loads-large-uncommon.osw +60 -86
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-loads-large-uncommon2.osw +60 -86
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-neighbor-shading.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-shielding-of-home.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-usage-multiplier.osw +52 -78
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-pv.osw +52 -78
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-vacancy-6-months.osw → base-schedules-stochastic-vacant.osw} +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-schedules-stochastic.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-schedules-user-specified.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-calendar-year-custom.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-daylight-saving-custom.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-daylight-saving-disabled.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-runperiod-1-month.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-timestep-10-mins.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/build_residential_hpxml_test.rb +71 -57
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-auto.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-double-exterior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-eaves.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-single-exterior-front.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-atticroof-conditioned-eaves-gable.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-atticroof-conditioned-eaves-hip.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-atticroof-flat.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-pv-shared.osw → extra-bldgtype-single-family-attached-double-exterior.osw} +62 -89
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-double-loaded-interior.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-dhw-shared-water-heater.osw → extra-bldgtype-single-family-attached-single-exterior-front.osw} +60 -86
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unconditioned-basement-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unconditioned-basement-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-multifamily.osw → extra-bldgtype-single-family-attached-unconditioned-basement.osw} +64 -91
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-dhw-solar-latitude.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-atticroof-conditioned-eaves-gable.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-atticroof-conditioned-eaves-hip.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-garage-atticroof-conditioned.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-garage-partially-protruded.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-windows-shading.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-gas-hot-tub-heater-with-zero-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-gas-pool-heater-with-zero-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-pv-roofpitch.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-schedules-random-seed.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-boiler-to-heat-pump.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-boiler-to-heating-system.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-fireplace-to-heat-pump.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-second-heating-system-fireplace.osw → extra-second-heating-system-fireplace-to-heating-system.osw} +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-portable-heater-to-heat-pump.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-second-heating-system-portable-heater.osw → extra-second-heating-system-portable-heater-to-heating-system.osw} +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-refrigerator.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-clothes-washer-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-dishwasher-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-extra-refrigerator-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-freezer-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-refrigerator-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-attic-with-floor-insulation.osw +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-attic-with-one-floor-above-grade.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-basement-with-ceiling-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/cooling-system-and-heat-pump.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/dhw-indirect-without-boiler.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/ducts-location-and-areas-not-same-type.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/foundation-wall-insulation-greater-than-height.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/heating-system-and-heat-pump.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-bottom-crawlspace-zero-foundation-height.osw +64 -89
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-bottom-slab-non-zero-foundation-height.osw +64 -89
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-no-building-orientation.osw +63 -88
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-hvac-programmable-thermostat.osw → invalid_files/multipliers-without-fuel-loads.osw} +54 -80
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-other-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-tv-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-dhw-uef.osw → invalid_files/multipliers-without-vehicle-plug-loads.osw} +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-well-pump-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-electric-heat-pump-water-heater.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-integer-ceiling-fan-quantity.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-integer-geometry-num-bathrooms.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-but-no-primary-heating.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-serves-majority-heat.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-serves-total-heat-load.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-attached-ambient.osw +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-attached-no-building-orientation.osw +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-detached-finished-basement-zero-foundation-height.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-detached-slab-non-zero-foundation-height.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-detached-with-shared-system.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/slab-non-zero-foundation-height-above-grade.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unconditioned-basement-with-wall-and-ceiling-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unvented-attic-with-floor-and-roof-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unvented-crawlspace-with-wall-and-ceiling-insulation.osw +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/vented-attic-with-floor-and-roof-insulation.osw +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/vented-crawlspace-with-wall-and-ceiling-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/zero-number-of-bedrooms.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/schedules/vacant.csv +8761 -0
- data/example_files/resources/hpxml-measures/Changelog.md +249 -0
- data/example_files/resources/hpxml-measures/Gemfile +2 -5
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.rb +404 -1357
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.xml +247 -171
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/BaseElements.xsd +11 -101
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/EPvalidator.xml +824 -301
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/HPXMLDataTypes.xsd +18 -35
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/HPXMLvalidator.xml +526 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/airflow.rb +135 -207
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constants.rb +14 -186
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constructions.rb +549 -93
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/energyplus.rb +12 -15
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/generator.rb +78 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/geometry.rb +413 -15
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hotwater_appliances.rb +48 -37
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml.rb +1627 -1227
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_defaults.rb +1192 -434
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac.rb +1555 -1616
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac_sizing.rb +1436 -1479
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/lighting.rb +3 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/location.rb +22 -10
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/meta_measure.rb +85 -19
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/minitest_helper.rb +4 -26
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/misc_loads.rb +22 -46
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/pv.rb +22 -21
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedules.rb +51 -14
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/simcontrols.rb +24 -7
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/unit_conversions.rb +2 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/validator.rb +80 -19
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/version.rb +9 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/waterheater.rb +106 -75
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/xmlhelper.rb +109 -34
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_airflow.rb +22 -36
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_defaults.rb +1565 -768
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_enclosure.rb +151 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_generator.rb +101 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb +9 -18
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac.rb +316 -28
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac_sizing.rb +53 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_lighting.rb +4 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_location.rb +13 -11
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_miscloads.rb +4 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_pv.rb +5 -3
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_simcontrols.rb +13 -11
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_validation.rb +102 -62
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_water_heater.rb +189 -35
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/util.rb +26 -0
- data/example_files/resources/hpxml-measures/README.md +5 -5
- data/example_files/resources/hpxml-measures/Rakefile +2 -10
- data/example_files/resources/hpxml-measures/SimulationOutputReport/measure.rb +416 -299
- data/example_files/resources/hpxml-measures/SimulationOutputReport/measure.xml +364 -481
- data/example_files/resources/hpxml-measures/SimulationOutputReport/resources/constants.rb +1 -2
- data/example_files/resources/hpxml-measures/SimulationOutputReport/tests/output_report_test.rb +327 -320
- data/example_files/resources/hpxml-measures/docs/source/build_residential_hpxml.rst +3 -3
- data/example_files/resources/hpxml-measures/docs/source/conf.py +11 -5
- data/example_files/resources/hpxml-measures/docs/source/getting_started.rst +6 -6
- data/example_files/resources/hpxml-measures/docs/source/index.rst +2 -2
- data/example_files/resources/hpxml-measures/docs/source/intro.rst +7 -109
- data/example_files/resources/hpxml-measures/docs/source/nstatic/stylesheet.css +13 -1
- data/example_files/resources/hpxml-measures/docs/source/workflow_inputs.rst +2482 -0
- data/example_files/resources/hpxml-measures/docs/source/workflow_outputs.rst +282 -0
- data/example_files/resources/hpxml-measures/tasks.rb +2494 -1248
- data/example_files/resources/hpxml-measures/weather/USA_AZ_Phoenix-Sky.Harbor.Intl.AP.722780_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_AZ_Phoenix-Sky.Harbor.Intl.AP.722780_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_CO_Denver.Intl.AP.725650_TMY3-cache.csv +10 -10
- data/example_files/resources/hpxml-measures/weather/USA_HI_Honolulu.Intl.AP.911820_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_HI_Honolulu.Intl.AP.911820_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_MT_Helena.Rgnl.AP.727720_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_MT_Helena.Rgnl.AP.727720_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_OR_Portland.Intl.AP.726980_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_OR_Portland.Intl.AP.726980_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/workflow/run_simulation.rb +96 -21
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-coal.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-appliances-dehumidifier-ief.xml → base-appliances-dehumidifier-ief-portable.xml} +8 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-appliances-dehumidifier-50percent.xml → base-appliances-dehumidifier-ief-whole-home.xml} +10 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-multiple.xml +535 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier.xml +525 -524
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-gas.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-modified.xml +564 -565
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-none.xml +513 -513
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-oil.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-propane.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-wood.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-cathedral.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-conditioned.xml +633 -634
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-flat.xml +531 -532
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-radiant-barrier.xml +517 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-unvented-insulated-roof.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-vented.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-multifamily-buffer-space.xml → base-bldgtype-multifamily-adjacent-to-multifamily-buffer-space.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-multiple.xml +554 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-non-freezing-space.xml → base-bldgtype-multifamily-adjacent-to-non-freezing-space.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-heated-space.xml → base-bldgtype-multifamily-adjacent-to-other-heated-space.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-housing-unit.xml → base-bldgtype-multifamily-adjacent-to-other-housing-unit.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-baseboard.xml +425 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-fan-coil-ducted.xml +457 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-fan-coil.xml +427 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-water-loop-heat-pump.xml +479 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-cooling-tower-water-loop-heat-pump.xml +474 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-baseboard.xml +408 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil-ducted.xml +439 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil-eae.xml +406 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil.xml +409 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-water-loop-heat-pump.xml +457 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-baseboard.xml +407 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-fan-coil-ducted.xml +438 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-fan-coil.xml +408 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-water-loop-heat-pump.xml +456 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-cooling-tower-only-water-loop-heat-pump.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-generator.xml +460 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-ground-loop-ground-to-air-heat-pump.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-laundry-room.xml +466 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-mechvent-shared-multiple.xml → base-bldgtype-multifamily-shared-mechvent-multiple.xml} +43 -415
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent-preconditioning.xml +489 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent.xml +473 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-pv.xml +465 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-water-heater-recirc.xml +458 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-water-heater.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily.xml +448 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-single-family-attached.xml +619 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless-outside.xml +516 -519
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless.xml +516 -519
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-2-speed.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-gshp.xml +7 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-hpwh.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-tankless.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-var-speed.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-dwhr.xml +567 -568
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-dse.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-outside.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-standbyloss.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-with-solar-fraction.xml +525 -528
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-electric.xml +567 -568
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-gas.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-hpwh.xml +566 -567
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-indirect.xml +522 -525
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-low-flow-fixtures.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-multiple.xml +575 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-none.xml +497 -497
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-demand.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-manual.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-nocontrol.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-temperature.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-timer.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-evacuated-tube.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-flat-plate.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-ics.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-fraction.xml +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-indirect-flat-plate.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-thermosyphon-flat-plate.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-coal.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-elec-uef.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-outside.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-uef.xml +565 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-outside.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-uef.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar-fraction.xml +569 -570
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-oil.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-wood.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-outside.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-uef.xml +561 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-uef.xml +561 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar-fraction.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-propane.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories-garage.xml +661 -664
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-1.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-2.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-4.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-5.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-garage.xml +636 -639
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-ach-house-pressure.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm-house-pressure.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm50.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-flue.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-natural-ach.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-overhangs.xml +582 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-rooftypes.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-shading.xml +601 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-level.xml +517 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-surfaces.xml +2474 -2493
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-surfaces2.xml +2475 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-walltypes.xml +754 -755
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-none.xml +504 -505
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-windows-interior-shading.xml → base-enclosure-windows-shading.xml} +23 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-ambient.xml +498 -497
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-basement-garage.xml +644 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-complex.xml +724 -729
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-slab-insulation.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-wall-interior-insulation.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-multiple.xml +685 -688
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-slab.xml +516 -517
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-above-grade.xml +609 -610
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-assembly-r.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-wall-insulation.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unvented-crawlspace.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-vented-crawlspace.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-walkout-basement.xml +627 -628
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-autosize.xml → base-hvac-air-to-air-heat-pump-1-speed-cooling-only.xml} +8 -12
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-1-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-air-to-air-heat-pump-1-speed-heating-only.xml} +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-2-speed.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-cooling-only.xml +553 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-1-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-1-speed-heating-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-manual-s-oversize-allowances.xml +561 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed.xml +558 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-2-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-air-to-air-heat-pump-2-speed-manual-s-oversize-allowances.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-2-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-2-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-var-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-air-to-air-heat-pump-var-speed-manual-s-oversize-allowances.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-var-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-var-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-elec-only-autosize.xml → base-hvac-autosize-boiler-elec-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-gas-central-ac-1-speed-autosize.xml → base-hvac-autosize-boiler-gas-central-ac-1-speed.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-gas-only-autosize.xml → base-hvac-autosize-boiler-gas-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-1-speed-autosize.xml → base-hvac-autosize-central-ac-only-1-speed.xml} +547 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-2-speed-autosize.xml → base-hvac-autosize-central-ac-only-2-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-var-speed-autosize.xml → base-hvac-autosize-central-ac-only-var-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-plus-air-to-air-heat-pump-heating-autosize.xml → base-hvac-autosize-central-ac-plus-air-to-air-heat-pump-heating.xml} +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed.xml +559 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-dual-fuel-mini-split-heat-pump-ducted-autosize.xml → base-hvac-autosize-dual-fuel-mini-split-heat-pump-ducted.xml} +557 -558
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-elec-resistance-only-autosize.xml → base-hvac-autosize-elec-resistance-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-evap-cooler-furnace-gas-autosize.xml → base-hvac-autosize-evap-cooler-furnace-gas.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-floor-furnace-propane-only-autosize.xml → base-hvac-autosize-floor-furnace-propane-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-elec-only-autosize.xml → base-hvac-autosize-furnace-elec-only.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-central-ac-2-speed-autosize.xml → base-hvac-autosize-furnace-gas-central-ac-2-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-central-ac-var-speed-autosize.xml → base-hvac-autosize-furnace-gas-central-ac-var-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-only-autosize.xml → base-hvac-autosize-furnace-gas-only.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-room-ac-autosize.xml → base-hvac-autosize-furnace-gas-room-ac.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-cooling-only.xml +555 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-heating-only.xml +560 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-ground-to-air-heat-pump-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-ground-to-air-heat-pump-manual-s-oversize-allowances.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-ground-to-air-heat-pump-autosize.xml → base-hvac-autosize-ground-to-air-heat-pump.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-air-conditioner-only-ducted.xml +547 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-cooling-only-autosize.xml → base-hvac-autosize-mini-split-heat-pump-ducted-cooling-only.xml} +551 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-heating-only-autosize.xml → base-hvac-autosize-mini-split-heat-pump-ducted-heating-only.xml} +556 -557
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-manual-s-oversize-allowances.xml +560 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-autosize.xml → base-hvac-autosize-mini-split-heat-pump-ducted.xml} +556 -557
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-room-ac-only-autosize.xml → base-hvac-autosize-room-ac-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-stove-oil-only-autosize.xml → base-hvac-autosize-stove-oil-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-wall-furnace-elec-only-autosize.xml → base-hvac-autosize-wall-furnace-elec-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-autosize.xml → base-hvac-autosize.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-coal-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-elec-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-central-ac-1-speed.xml +571 -573
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-only.xml +519 -522
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-oil-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-propane-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-wood-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-1-speed.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-2-speed.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-var-speed.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-plus-air-to-air-heat-pump-heating.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dse.xml +532 -535
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-electric.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-2-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-var-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-mini-split-heat-pump-ducted.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-leakage-percent.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-elec-resistance-only.xml +509 -512
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-furnace-gas.xml +555 -555
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only-ducted.xml +536 -528
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only.xml +503 -505
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fireplace-wood-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fixed-heater-gas-only.xml +6 -57
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-floor-furnace-propane-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-coal-only.xml +549 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-central-ac-1-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-2-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-var-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only.xml +5 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-room-ac.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-oil-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-propane-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-wood-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-x3-dse.xml +576 -579
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-cooling-only.xml +557 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-heating-only.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump.xml +7 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-flowrate.xml → base-hvac-install-quality-airflow-defect-furnace-gas-central-ac-1-speed.xml} +8 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{invalid_files/heat-pump-mixed-fixed-and-autosize-capacities2.xml → base-hvac-install-quality-all-air-to-air-heat-pump-1-speed.xml} +13 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-air-to-air-heat-pump-2-speed.xml +567 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-air-to-air-heat-pump-var-speed.xml +567 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-central-ac-1-speed.xml +572 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-central-ac-2-speed.xml +572 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-central-ac-var-speed.xml +572 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-only.xml +553 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-ground-to-air-heat-pump.xml +566 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-air-conditioner-only-ducted-autosize.xml → base-hvac-install-quality-all-mini-split-air-conditioner-only-ducted.xml} +10 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-autosize-manual-s-oversize-allowances.xml → base-hvac-install-quality-all-mini-split-heat-pump-ducted.xml} +13 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-blower-efficiency-furnace-gas-central-ac-1-speed.xml +569 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-misc-shelter-coefficient.xml → base-hvac-install-quality-charge-defect-furnace-gas-central-ac-1-speed.xml} +9 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-none-furnace-gas-central-ac-1-speed.xml +570 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ducted.xml +547 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ductless.xml +508 -511
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-cooling-only.xml +554 -555
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-heating-only.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless.xml +515 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-multiple.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-none.xml +486 -489
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-portable-heater-gas-only.xml +6 -57
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-programmable-thermostat-detailed.xml +567 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-programmable-thermostat.xml +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-33percent.xml +508 -511
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only.xml +508 -511
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-oil-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-wood-pellets-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized-allow-increased-fixed-capacities.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-wall-furnace-elec-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-ceiling-fans.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-detailed.xml +585 -586
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-none.xml +488 -489
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-AMY-2012.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-baltimore-md.xml +573 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-dallas-tx.xml +516 -517
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-duluth-mn.xml +573 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-helena-mt.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-honolulu-hi.xml +517 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-miami-fl.xml +516 -517
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-phoenix-az.xml +517 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-portland-or.xml +577 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-balanced.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-bath-kitchen-fans.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-dse.xml +545 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-evap-cooler-only-ducted.xml +549 -541
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv-atre-asre.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust-rated-flow-rate.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv-asre.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-multiple.xml +796 -795
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-supply.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-whole-house-fan.xml +572 -573
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-defaults.xml +478 -495
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators.xml +579 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon.xml +758 -833
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon2.xml +749 -820
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-none.xml +550 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-neighbor-shading.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/{invalid_files/invalid-calendar-year.xml → base-misc-shielding-of-home.xml} +7 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-usage-multiplier.xml +728 -725
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-multiple-buildings.xml +1657 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-stochastic-vacant.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-stochastic.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-user-specified.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-calendar-year-custom.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-custom.xml +569 -570
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-disabled.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-runperiod-1-month.xml +566 -567
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/boiler-invalid-afue.xml +519 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/cfis-with-hydronic-distribution.xml +532 -535
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/clothes-dryer-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/clothes-washer-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/cooking-range-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dehumidifier-fraction-served.xml +535 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dehumidifier-setpoints.xml +535 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dhw-frac-load-served.xml +575 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-dhw-uef.xml → invalid_files/dhw-invalid-ef-tank.xml} +7 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dhw-invalid-uef-tank-heat-pump.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dishwasher-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-leakage-cfm25.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-leakage-percent.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-location-unconditioned-space.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duplicate-id.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-attic-missing-roof.xml +546 -547
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-basement-missing-exterior-foundation-wall.xml +543 -544
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-basement-missing-slab.xml +546 -545
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-floor-area-exceeds-cfa.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-floor-area-exceeds-cfa2.xml +448 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-exterior-wall.xml +613 -616
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-roof-ceiling.xml +626 -629
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-slab.xml +610 -611
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-ceiling-roof.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-exterior-wall.xml +472 -473
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-floor-slab.xml +488 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-sensible-fuel-load.xml +760 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-sensible-plug-load.xml +759 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-total-fuel-load.xml +761 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-total-plug-load.xml +759 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/furnace-invalid-afue.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/generator-number-of-bedrooms-served.xml +460 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/generator-output-greater-than-consumption.xml +579 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/heat-pump-mixed-fixed-and-autosize-capacities.xml +559 -560
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-multiple-attached-cooling.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-multiple-attached-heating.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-return-duct-leakage-missing.xml +528 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-dse-multiple-attached-cooling.xml +546 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-dse-multiple-attached-heating.xml +546 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-frac-load-served.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-inconsistent-fan-powers.xml +569 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-invalid-distribution-system-type.xml +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-shared-negative-seer-eq.xml +407 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-assembly-effective-rvalue.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-boolean.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-float.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-integer.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-daylight-saving.xml +569 -567
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-distribution-cfa-served.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-epw-filepath.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-facility-type-equipment.xml +466 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-facility-type-surfaces.xml +644 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/{appliances-location-unconditioned-space.xml → invalid-foundation-wall-properties.xml} +39 -29
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-id.xml +591 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-id2.xml +591 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-infiltration-volume.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-input-parameters.xml +565 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-neighbor-shading-azimuth.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-number-of-bedrooms-served.xml +465 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/{slab-zero-exposed-perimeter.xml → invalid-number-of-conditioned-floors.xml} +7 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-number-of-units-served.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-relatedhvac-desuperheater.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-relatedhvac-dhw-indirect.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-runperiod.xml +564 -565
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-schema-version.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-shared-vent-in-unit-flowrate.xml +473 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-timestep.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-window-height.xml +582 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/lighting-fractions.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/missing-duct-location.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/missing-elements.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-appliance.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-duct.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-surface.xml +575 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-water-heater.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-buildings-without-building-id.xml +1657 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-buildings-wrong-building-id.xml +1657 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-shared-cooling-systems.xml +432 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-shared-heating-systems.xml +434 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/net-area-negative-roof.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/net-area-negative-wall.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/num-bedrooms-exceeds-limit.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/orphaned-hvac-distribution.xml +546 -547
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerator-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerators-multiple-primary.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerators-no-primary.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/repeated-relatedhvac-desuperheater.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/repeated-relatedhvac-dhw-indirect.xml +526 -529
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-fraction-one.xml +571 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-combi-tankless.xml +531 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-desuperheater.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-dhw-indirect.xml +531 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-cfis.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-door.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-hvac-distribution.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-shared-clothes-washer-water-heater.xml +465 -827
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-shared-dishwasher-water-heater.xml +465 -827
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-skylight.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-solar-thermal-system.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-window.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/water-heater-location-other.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/water-heater-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/template.osw +5 -1
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L302XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L304XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L322XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L324XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results.csv +294 -0
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_ashrae_140.csv +27 -0
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_hvac_sizing.csv +294 -0
- data/example_files/resources/hpxml-measures/workflow/tests/compare.rb +130 -0
- data/example_files/resources/hpxml-measures/workflow/tests/hpxml_translator_test.rb +522 -527
- data/example_files/{measures/BuildResidentialModel/resources → resources}/measure-info.json +0 -0
- data/example_files/{measures/BuildResidentialModel/resources → resources}/meta_measure.rb +53 -44
- data/example_files/validation_schema.yaml +149 -0
- data/example_files/visualization/input_visualization_feature.html +213 -56
- data/example_files/visualization/input_visualization_scenario.html +92 -30
- data/lib/uo_cli.rb +406 -128
- data/lib/uo_cli/version.rb +17 -7
- data/requirements.txt +2 -0
- data/scripts/setup-env-gitbash.sh +5 -5
- data/scripts/setup-env-unix.sh +4 -4
- data/scripts/setup-env.bat +14 -11
- data/scripts/setup-env.ps1 +13 -10
- data/uo_cli.gemspec +10 -8
- metadata +390 -130
- data/developer_nrel_key.rb +0 -31
- data/example_files/measures/ResidentialGeometryCreateMultifamily/measure.rb +0 -1005
- data/example_files/measures/ResidentialGeometryCreateMultifamily/measure.xml +0 -326
- data/example_files/measures/ResidentialGeometryCreateMultifamily/tests/create_residential_multifamily_geometry_test.rb +0 -477
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/measure.rb +0 -1039
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/measure.xml +0 -393
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/tests/create_residential_single_family_attached_geometry_test.rb +0 -456
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/measure.rb +0 -979
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/measure.xml +0 -388
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/tests/create_residential_single_family_detached_geometry_test.rb +0 -704
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/location.rb +0 -24
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_config.yml +0 -61
- data/example_files/resources/hpxml-measures/docs/source/hpxml_to_openstudio.rst +0 -1386
- data/example_files/resources/hpxml-measures/docs/source/simulation_output_report.rst +0 -252
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-shared-laundry-room.xml +0 -828
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-shared-water-heater-recirc.xml +0 -820
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-shared-water-heater.xml +0 -813
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-attached-multifamily.xml +0 -810
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-common-surfaces.xml +0 -928
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ideal-air.xml +0 -501
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-multiple2.xml +0 -838
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-baseboard.xml +0 -777
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-fan-coil-ducted.xml +0 -808
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-fan-coil.xml +0 -780
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-water-loop-heat-pump.xml +0 -820
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-cooling-tower-water-loop-heat-pump.xml +0 -815
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-baseboard.xml +0 -760
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-fan-coil-ducted.xml +0 -790
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-fan-coil-eae.xml +0 -759
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-fan-coil.xml +0 -762
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-water-loop-heat-pump.xml +0 -796
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-baseboard.xml +0 -759
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-fan-coil-ducted.xml +0 -789
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-fan-coil.xml +0 -761
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-water-loop-heat-pump.xml +0 -796
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-cooling-tower-only-water-loop-heat-pump.xml +0 -791
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-ground-loop-ground-to-air-heat-pump.xml +0 -814
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-shared-preconditioning.xml +0 -851
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-shared.xml +0 -835
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-shared.xml +0 -827
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/coal-for-non-boiler-heating.xml +0 -514
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-facility-type.xml +0 -828
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-window-interior-shading.xml +0 -564
@@ -0,0 +1,26 @@
|
|
1
|
+
# frozen_string_literal: true
|
2
|
+
|
3
|
+
def get_ems_values(ems_objects, name)
|
4
|
+
values = {}
|
5
|
+
ems_objects.each do |ems_object|
|
6
|
+
next unless ems_object.name.to_s.include? name.gsub(' ', '_')
|
7
|
+
|
8
|
+
ems_object.lines.each do |line|
|
9
|
+
next unless line.downcase.start_with? 'set'
|
10
|
+
|
11
|
+
lhs, rhs = line.split('=')
|
12
|
+
lhs = lhs.gsub('Set', '').gsub('set', '').strip
|
13
|
+
rhs = rhs.gsub(',', '').gsub(';', '').strip
|
14
|
+
values[lhs] = [] if values[lhs].nil?
|
15
|
+
# eg. "Q = Q + 1.5"
|
16
|
+
if rhs.include? '+'
|
17
|
+
rhs_els = rhs.split('+')
|
18
|
+
rhs = rhs_els.map { |s| s.to_f }.sum(0.0)
|
19
|
+
else
|
20
|
+
rhs = rhs.to_f
|
21
|
+
end
|
22
|
+
values[lhs] << rhs
|
23
|
+
end
|
24
|
+
end
|
25
|
+
return values
|
26
|
+
end
|
@@ -1,8 +1,8 @@
|
|
1
1
|
# OpenStudio-HPXML
|
2
2
|
|
3
|
-
[![
|
3
|
+
[![GitHub release (latest by date including pre-releases)](https://img.shields.io/github/v/release/NREL/OpenStudio-HPXML?include_prereleases)](https://github.com/NREL/OpenStudio-HPXML/releases)
|
4
|
+
[![ci](https://github.com/NREL/OpenStudio-HPXML/workflows/ci/badge.svg)](https://github.com/NREL/OpenStudio-HPXML/actions)
|
4
5
|
[![Documentation Status](https://readthedocs.org/projects/openstudio-hpxml/badge/?version=latest)](https://openstudio-hpxml.readthedocs.io/en/latest/?badge=latest)
|
5
|
-
[![codecov](https://codecov.io/gh/NREL/OpenStudio-HPXML/branch/master/graph/badge.svg)](https://codecov.io/gh/NREL/OpenStudio-HPXML)
|
6
6
|
|
7
7
|
OpenStudio-HPXML allows running residential EnergyPlus simulations using an [HPXML file](https://hpxml.nrel.gov/) for the building description.
|
8
8
|
A Schematron document (`HPXMLtoOpenStudio/resources/EPvalidator.xml`) for the EnergyPlus use case is used to validate that the appropriate HPXML inputs are provided to run EnergyPlus.
|
@@ -30,10 +30,10 @@ This repository contains three OpenStudio measures:
|
|
30
30
|
|
31
31
|
The OpenStudio-HPXML workflow is used by a number of other residential projects, including:
|
32
32
|
- [Energy Rating Index (ERI)](https://github.com/NREL/OpenStudio-ERI)
|
33
|
-
- Home Energy Score (
|
34
|
-
- Weatherization Assistant (
|
33
|
+
- Home Energy Score (pending)
|
34
|
+
- Weatherization Assistant (pending)
|
35
35
|
- ResStock (pending)
|
36
|
-
- UrbanOpt
|
36
|
+
- [UrbanOpt](https://www.nrel.gov/buildings/urbanopt.html)
|
37
37
|
|
38
38
|
## License
|
39
39
|
|
@@ -5,18 +5,10 @@
|
|
5
5
|
|
6
6
|
require 'rake'
|
7
7
|
require 'rake/testtask'
|
8
|
-
require 'ci/reporter/rake/minitest'
|
9
8
|
|
10
|
-
desc 'Run
|
11
|
-
Rake::TestTask.new('test_validation') do |t|
|
12
|
-
t.test_files = Dir['HPXMLtoOpenStudio/tests/test_validation.rb']
|
13
|
-
t.warning = false
|
14
|
-
t.verbose = true
|
15
|
-
end
|
16
|
-
|
17
|
-
desc 'Run all tests (excluding validation test)'
|
9
|
+
desc 'Run all tests'
|
18
10
|
Rake::TestTask.new('test_all') do |t|
|
19
|
-
t.test_files = Dir['*/tests/*.rb'] - Dir['
|
11
|
+
t.test_files = Dir['*/tests/*.rb'] - Dir['workflow/tests/compare.rb']
|
20
12
|
t.warning = false
|
21
13
|
t.verbose = true
|
22
14
|
end
|
@@ -23,13 +23,22 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
23
23
|
|
24
24
|
# human readable description of modeling approach
|
25
25
|
def modeler_description
|
26
|
-
return 'Processes EnergyPlus simulation outputs in order to generate an annual output
|
26
|
+
return 'Processes EnergyPlus simulation outputs in order to generate an annual output file and an optional timeseries output file.'
|
27
27
|
end
|
28
28
|
|
29
29
|
# define the arguments that the user will input
|
30
30
|
def arguments(model)
|
31
31
|
args = OpenStudio::Measure::OSArgumentVector.new
|
32
32
|
|
33
|
+
format_chs = OpenStudio::StringVector.new
|
34
|
+
format_chs << 'csv'
|
35
|
+
format_chs << 'json'
|
36
|
+
arg = OpenStudio::Measure::OSArgument::makeChoiceArgument('output_format', format_chs, false)
|
37
|
+
arg.setDisplayName('Output Format')
|
38
|
+
arg.setDescription('The file format of the annual (and timeseries, if requested) outputs.')
|
39
|
+
arg.setDefaultValue('csv')
|
40
|
+
args << arg
|
41
|
+
|
33
42
|
timeseries_frequency_chs = OpenStudio::StringVector.new
|
34
43
|
timeseries_frequency_chs << 'none'
|
35
44
|
reporting_frequency_map.keys.each do |freq|
|
@@ -61,13 +70,19 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
61
70
|
|
62
71
|
arg = OpenStudio::Measure::OSArgument::makeBoolArgument('include_timeseries_total_loads', true)
|
63
72
|
arg.setDisplayName('Generate Timeseries Output: Total Loads')
|
64
|
-
arg.setDescription('Generates timeseries heating
|
73
|
+
arg.setDescription('Generates timeseries total heating, cooling, and hot water loads.')
|
65
74
|
arg.setDefaultValue(false)
|
66
75
|
args << arg
|
67
76
|
|
68
77
|
arg = OpenStudio::Measure::OSArgument::makeBoolArgument('include_timeseries_component_loads', true)
|
69
78
|
arg.setDisplayName('Generate Timeseries Output: Component Loads')
|
70
|
-
arg.setDescription('Generates timeseries heating
|
79
|
+
arg.setDescription('Generates timeseries heating and cooling loads disaggregated by component type.')
|
80
|
+
arg.setDefaultValue(false)
|
81
|
+
args << arg
|
82
|
+
|
83
|
+
arg = OpenStudio::Measure::OSArgument::makeBoolArgument('include_timeseries_unmet_loads', true)
|
84
|
+
arg.setDisplayName('Generate Timeseries Output: Unmet Loads')
|
85
|
+
arg.setDescription('Generates timeseries unmet heating and cooling loads.')
|
71
86
|
arg.setDefaultValue(false)
|
72
87
|
args << arg
|
73
88
|
|
@@ -139,21 +154,32 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
139
154
|
# Get a few things from the model
|
140
155
|
get_object_maps()
|
141
156
|
|
142
|
-
|
157
|
+
total_loads_program = @model.getModelObjectByName(Constants.ObjectNameTotalLoadsProgram.gsub(' ', '_')).get.to_EnergyManagementSystemProgram.get
|
158
|
+
comp_loads_program = @model.getModelObjectByName(Constants.ObjectNameComponentLoadsProgram.gsub(' ', '_'))
|
159
|
+
if comp_loads_program.is_initialized
|
160
|
+
comp_loads_program = comp_loads_program.get.to_EnergyManagementSystemProgram.get
|
161
|
+
else
|
162
|
+
comp_loads_program = nil
|
163
|
+
end
|
143
164
|
|
144
165
|
# Annual outputs
|
145
166
|
|
146
167
|
# Add meters to increase precision of outputs relative to, e.g., ABUPS report
|
147
168
|
meters = []
|
169
|
+
meters << 'ElectricityProduced:Facility' # Used for error checking
|
148
170
|
@fuels.each do |fuel_type, fuel|
|
149
|
-
meters
|
171
|
+
fuel.meters.each do |meter|
|
172
|
+
meters << meter
|
173
|
+
end
|
150
174
|
end
|
151
175
|
@end_uses.each do |key, end_use|
|
152
|
-
|
176
|
+
next if end_use.meters.nil?
|
177
|
+
|
178
|
+
end_use.meters.each do |meter|
|
179
|
+
meters << meter
|
180
|
+
end
|
153
181
|
end
|
154
182
|
meters.each do |meter|
|
155
|
-
next if meter.nil?
|
156
|
-
|
157
183
|
result << OpenStudio::IdfObject.load("Output:Meter,#{meter},runperiod;").get
|
158
184
|
end
|
159
185
|
|
@@ -175,18 +201,23 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
175
201
|
|
176
202
|
# Add peak electricity outputs
|
177
203
|
@peak_fuels.each do |key, peak_fuel|
|
178
|
-
|
204
|
+
peak_fuel.meters.each do |meter|
|
205
|
+
result << OpenStudio::IdfObject.load("Output:Table:Monthly,#{peak_fuel.report},2,#{meter},HoursPositive,Electricity:Facility,MaximumDuringHoursShown;").get
|
206
|
+
end
|
179
207
|
end
|
180
208
|
|
181
209
|
# Add component load outputs
|
182
210
|
@component_loads.each do |key, comp_load|
|
183
|
-
|
211
|
+
next if comp_loads_program.nil?
|
212
|
+
result << OpenStudio::IdfObject.load("EnergyManagementSystem:OutputVariable,#{comp_load.ems_variable}_annual_outvar,#{comp_load.ems_variable},Summed,ZoneTimestep,#{comp_loads_program.name},J;").get
|
184
213
|
result << OpenStudio::IdfObject.load("Output:Variable,*,#{comp_load.ems_variable}_annual_outvar,runperiod;").get
|
185
214
|
end
|
215
|
+
|
216
|
+
# Add total load outputs
|
186
217
|
@loads.each do |load_type, load|
|
187
218
|
next if load.ems_variable.nil?
|
188
219
|
|
189
|
-
result << OpenStudio::IdfObject.load("EnergyManagementSystem:OutputVariable,#{load.ems_variable}_annual_outvar,#{load.ems_variable},Summed,ZoneTimestep,#{
|
220
|
+
result << OpenStudio::IdfObject.load("EnergyManagementSystem:OutputVariable,#{load.ems_variable}_annual_outvar,#{load.ems_variable},Summed,ZoneTimestep,#{total_loads_program.name},J;").get
|
190
221
|
result << OpenStudio::IdfObject.load("Output:Variable,*,#{load.ems_variable}_annual_outvar,runperiod;").get
|
191
222
|
end
|
192
223
|
|
@@ -204,6 +235,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
204
235
|
include_timeseries_hot_water_uses = runner.getBoolArgumentValue('include_timeseries_hot_water_uses', user_arguments)
|
205
236
|
include_timeseries_total_loads = runner.getBoolArgumentValue('include_timeseries_total_loads', user_arguments)
|
206
237
|
include_timeseries_component_loads = runner.getBoolArgumentValue('include_timeseries_component_loads', user_arguments)
|
238
|
+
include_timeseries_unmet_loads = runner.getBoolArgumentValue('include_timeseries_unmet_loads', user_arguments)
|
207
239
|
include_timeseries_zone_temperatures = runner.getBoolArgumentValue('include_timeseries_zone_temperatures', user_arguments)
|
208
240
|
include_timeseries_airflows = runner.getBoolArgumentValue('include_timeseries_airflows', user_arguments)
|
209
241
|
include_timeseries_weather = runner.getBoolArgumentValue('include_timeseries_weather', user_arguments)
|
@@ -244,15 +276,19 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
244
276
|
|
245
277
|
if include_timeseries_fuel_consumptions
|
246
278
|
@fuels.each do |fuel_type, fuel|
|
247
|
-
|
279
|
+
fuel.meters.each do |meter|
|
280
|
+
result << OpenStudio::IdfObject.load("Output:Meter,#{meter},#{timeseries_frequency};").get
|
281
|
+
end
|
248
282
|
end
|
249
283
|
end
|
250
284
|
|
251
285
|
if include_timeseries_end_use_consumptions
|
252
286
|
@end_uses.each do |key, end_use|
|
253
|
-
next if end_use.
|
287
|
+
next if end_use.meters.nil?
|
254
288
|
|
255
|
-
|
289
|
+
end_use.meters.each do |meter|
|
290
|
+
result << OpenStudio::IdfObject.load("Output:Meter,#{meter},#{timeseries_frequency};").get
|
291
|
+
end
|
256
292
|
end
|
257
293
|
# Add output variables for individual HVAC/DHW systems
|
258
294
|
add_object_output_variables(timeseries_frequency).each do |outvar|
|
@@ -268,18 +304,28 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
268
304
|
@loads.each do |load_type, load|
|
269
305
|
next if load.ems_variable.nil?
|
270
306
|
|
271
|
-
result << OpenStudio::IdfObject.load("EnergyManagementSystem:OutputVariable,#{load.ems_variable}_timeseries_outvar,#{load.ems_variable},Summed,ZoneTimestep,#{
|
307
|
+
result << OpenStudio::IdfObject.load("EnergyManagementSystem:OutputVariable,#{load.ems_variable}_timeseries_outvar,#{load.ems_variable},Summed,ZoneTimestep,#{total_loads_program.name},J;").get
|
272
308
|
result << OpenStudio::IdfObject.load("Output:Variable,*,#{load.ems_variable}_timeseries_outvar,#{timeseries_frequency};").get
|
273
309
|
end
|
310
|
+
# And add HotWaterDelivered:
|
311
|
+
result << OpenStudio::IdfObject.load("Output:Variable,*,Water Use Connections Plant Hot Water Energy,#{timeseries_frequency};").get
|
274
312
|
end
|
275
313
|
|
276
314
|
if include_timeseries_component_loads
|
277
315
|
@component_loads.each do |key, comp_load|
|
278
|
-
|
316
|
+
next if comp_loads_program.nil?
|
317
|
+
|
318
|
+
result << OpenStudio::IdfObject.load("EnergyManagementSystem:OutputVariable,#{comp_load.ems_variable}_timeseries_outvar,#{comp_load.ems_variable},Summed,ZoneTimestep,#{comp_loads_program.name},J;").get
|
279
319
|
result << OpenStudio::IdfObject.load("Output:Variable,*,#{comp_load.ems_variable}_timeseries_outvar,#{timeseries_frequency};").get
|
280
320
|
end
|
281
321
|
end
|
282
322
|
|
323
|
+
if include_timeseries_unmet_loads
|
324
|
+
@unmet_loads.each do |load_type, unmet_load|
|
325
|
+
result << OpenStudio::IdfObject.load("Output:Variable,#{unmet_load.key},#{unmet_load.variable},#{timeseries_frequency};").get
|
326
|
+
end
|
327
|
+
end
|
328
|
+
|
283
329
|
return result
|
284
330
|
end
|
285
331
|
|
@@ -299,6 +345,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
299
345
|
return false
|
300
346
|
end
|
301
347
|
|
348
|
+
output_format = runner.getStringArgumentValue('output_format', user_arguments)
|
302
349
|
timeseries_frequency = runner.getStringArgumentValue('timeseries_frequency', user_arguments)
|
303
350
|
if timeseries_frequency != 'none'
|
304
351
|
include_timeseries_fuel_consumptions = runner.getBoolArgumentValue('include_timeseries_fuel_consumptions', user_arguments)
|
@@ -306,6 +353,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
306
353
|
include_timeseries_hot_water_uses = runner.getBoolArgumentValue('include_timeseries_hot_water_uses', user_arguments)
|
307
354
|
include_timeseries_total_loads = runner.getBoolArgumentValue('include_timeseries_total_loads', user_arguments)
|
308
355
|
include_timeseries_component_loads = runner.getBoolArgumentValue('include_timeseries_component_loads', user_arguments)
|
356
|
+
include_timeseries_unmet_loads = runner.getBoolArgumentValue('include_timeseries_unmet_loads', user_arguments)
|
309
357
|
include_timeseries_zone_temperatures = runner.getBoolArgumentValue('include_timeseries_zone_temperatures', user_arguments)
|
310
358
|
include_timeseries_airflows = runner.getBoolArgumentValue('include_timeseries_airflows', user_arguments)
|
311
359
|
include_timeseries_weather = runner.getBoolArgumentValue('include_timeseries_weather', user_arguments)
|
@@ -324,8 +372,9 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
324
372
|
@model.setSqlFile(@sqlFile)
|
325
373
|
|
326
374
|
hpxml_path = @model.getBuilding.additionalProperties.getFeatureAsString('hpxml_path').get
|
327
|
-
|
328
|
-
|
375
|
+
building_id = @model.getBuilding.additionalProperties.getFeatureAsString('building_id').get
|
376
|
+
@hpxml = HPXML.new(hpxml_path: hpxml_path, building_id: building_id)
|
377
|
+
HVAC.apply_shared_systems(@hpxml) # Needed for ERI shared HVAC systems
|
329
378
|
get_object_maps()
|
330
379
|
@eri_design = @hpxml.header.eri_design
|
331
380
|
|
@@ -335,15 +384,15 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
335
384
|
if not @eri_design.nil?
|
336
385
|
# ERI run, store files in a particular location
|
337
386
|
output_dir = File.dirname(hpxml_path)
|
338
|
-
|
339
|
-
|
340
|
-
|
341
|
-
|
387
|
+
hpxml_name = File.basename(hpxml_path).gsub('.xml', '')
|
388
|
+
annual_output_path = File.join(output_dir, "#{hpxml_name}.#{output_format}")
|
389
|
+
eri_output_path = File.join(output_dir, "#{hpxml_name}_ERI.csv")
|
390
|
+
timeseries_output_path = File.join(output_dir, "#{hpxml_name}_#{timeseries_frequency.capitalize}.#{output_format}")
|
342
391
|
else
|
343
392
|
output_dir = File.dirname(@sqlFile.path.to_s)
|
344
|
-
|
345
|
-
|
346
|
-
|
393
|
+
annual_output_path = File.join(output_dir, "results_annual.#{output_format}")
|
394
|
+
eri_output_path = nil
|
395
|
+
timeseries_output_path = File.join(output_dir, "results_timeseries.#{output_format}")
|
347
396
|
end
|
348
397
|
|
349
398
|
@timestamps = get_timestamps(timeseries_frequency)
|
@@ -355,6 +404,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
355
404
|
include_timeseries_hot_water_uses,
|
356
405
|
include_timeseries_total_loads,
|
357
406
|
include_timeseries_component_loads,
|
407
|
+
include_timeseries_unmet_loads,
|
358
408
|
include_timeseries_zone_temperatures,
|
359
409
|
include_timeseries_airflows,
|
360
410
|
include_timeseries_weather)
|
@@ -370,15 +420,18 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
370
420
|
end
|
371
421
|
|
372
422
|
# Write/report results
|
373
|
-
write_annual_output_results(runner, outputs,
|
423
|
+
write_annual_output_results(runner, outputs, output_format, annual_output_path)
|
374
424
|
report_sim_outputs(outputs, runner)
|
375
|
-
write_eri_output_results(outputs,
|
376
|
-
write_timeseries_output_results(runner,
|
425
|
+
write_eri_output_results(outputs, eri_output_path)
|
426
|
+
write_timeseries_output_results(runner, output_format,
|
427
|
+
timeseries_output_path,
|
428
|
+
timeseries_frequency,
|
377
429
|
include_timeseries_fuel_consumptions,
|
378
430
|
include_timeseries_end_use_consumptions,
|
379
431
|
include_timeseries_hot_water_uses,
|
380
432
|
include_timeseries_total_loads,
|
381
433
|
include_timeseries_component_loads,
|
434
|
+
include_timeseries_unmet_loads,
|
382
435
|
include_timeseries_zone_temperatures,
|
383
436
|
include_timeseries_airflows,
|
384
437
|
include_timeseries_weather)
|
@@ -404,7 +457,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
404
457
|
timestamps = []
|
405
458
|
values.get.each do |value|
|
406
459
|
year, month, day, hour, minute = value.split(' ')
|
407
|
-
ts =
|
460
|
+
ts = Time.new(year, month, day, hour, minute)
|
408
461
|
timestamps << ts.strftime('%Y/%m/%d %H:%M:00')
|
409
462
|
end
|
410
463
|
|
@@ -417,6 +470,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
417
470
|
include_timeseries_hot_water_uses,
|
418
471
|
include_timeseries_total_loads,
|
419
472
|
include_timeseries_component_loads,
|
473
|
+
include_timeseries_unmet_loads,
|
420
474
|
include_timeseries_zone_temperatures,
|
421
475
|
include_timeseries_airflows,
|
422
476
|
include_timeseries_weather)
|
@@ -433,6 +487,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
433
487
|
outputs[:hpxml_cfa] = @hpxml.building_construction.conditioned_floor_area
|
434
488
|
outputs[:hpxml_nbr] = @hpxml.building_construction.number_of_bedrooms
|
435
489
|
outputs[:hpxml_nst] = @hpxml.building_construction.number_of_conditioned_floors_above_grade
|
490
|
+
outputs[:hpxml_residential_facility_type] = @hpxml.building_construction.residential_facility_type
|
436
491
|
|
437
492
|
# HPXML Systems
|
438
493
|
if not @eri_design.nil?
|
@@ -456,15 +511,18 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
456
511
|
|
457
512
|
# Fuel Uses
|
458
513
|
@fuels.each do |fuel_type, fuel|
|
459
|
-
fuel.annual_output = get_report_meter_data_annual(fuel.
|
514
|
+
fuel.annual_output = get_report_meter_data_annual(fuel.meters)
|
460
515
|
if include_timeseries_fuel_consumptions
|
461
|
-
fuel.timeseries_output = get_report_meter_data_timeseries(
|
516
|
+
fuel.timeseries_output = get_report_meter_data_timeseries(fuel.meters, UnitConversions.convert(1.0, 'J', fuel.timeseries_units), 0, timeseries_frequency)
|
462
517
|
end
|
463
518
|
end
|
464
519
|
|
520
|
+
# Electricity Produced (used for error checking)
|
521
|
+
outputs[:total_elec_produced] = get_report_meter_data_annual(['ElectricityProduced:Facility'])
|
522
|
+
|
465
523
|
# Peak Electricity Consumption
|
466
524
|
@peak_fuels.each do |key, peak_fuel|
|
467
|
-
peak_fuel.annual_output = get_tabular_data_value(peak_fuel.report.upcase, 'Meter', 'Custom Monthly Report', 'Maximum of Months', 'ELECTRICITY:FACILITY {MAX FOR HOURS SHOWN', peak_fuel.annual_units)
|
525
|
+
peak_fuel.annual_output = get_tabular_data_value(peak_fuel.report.upcase, 'Meter', 'Custom Monthly Report', ['Maximum of Months'], 'ELECTRICITY:FACILITY {MAX FOR HOURS SHOWN', peak_fuel.annual_units)
|
468
526
|
end
|
469
527
|
|
470
528
|
# Total loads
|
@@ -488,34 +546,45 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
488
546
|
# Unmet loads (heating/cooling energy delivered by backup ideal air system)
|
489
547
|
@unmet_loads.each do |load_type, unmet_load|
|
490
548
|
unmet_load.annual_output = get_report_variable_data_annual([unmet_load.key.upcase], [unmet_load.variable])
|
549
|
+
if include_timeseries_unmet_loads
|
550
|
+
unmet_load.timeseries_output = get_report_variable_data_timeseries([unmet_load.key.upcase], [unmet_load.variable], UnitConversions.convert(1.0, 'J', unmet_load.timeseries_units), 0, timeseries_frequency)
|
551
|
+
end
|
491
552
|
end
|
492
553
|
|
493
|
-
# Ideal system loads (expected fraction of loads that are not met by HVAC)
|
554
|
+
# Ideal system loads (expected fraction of loads that are not met by partial HVAC (e.g., room AC that meets 30% of load))
|
494
555
|
@ideal_system_loads.each do |load_type, ideal_load|
|
495
556
|
ideal_load.annual_output = get_report_variable_data_annual([ideal_load.key.upcase], [ideal_load.variable])
|
496
557
|
end
|
497
558
|
|
498
559
|
# Peak Building Space Heating/Cooling Loads (total heating/cooling energy delivered including backup ideal air system)
|
499
560
|
@peak_loads.each do |load_type, peak_load|
|
500
|
-
peak_load.annual_output = UnitConversions.convert(get_tabular_data_value('EnergyMeters', 'Entire Facility', 'Annual and Peak Values - Other', peak_load.
|
561
|
+
peak_load.annual_output = UnitConversions.convert(get_tabular_data_value('EnergyMeters', 'Entire Facility', 'Annual and Peak Values - Other', peak_load.meters, 'Maximum Value', 'W'), 'Wh', peak_load.annual_units)
|
501
562
|
end
|
502
563
|
|
503
564
|
# End Uses (derived from meters)
|
504
565
|
@end_uses.each do |key, end_use|
|
505
|
-
next if end_use.
|
566
|
+
next if end_use.meters.nil?
|
506
567
|
|
507
568
|
fuel_type, end_use_type = key
|
508
|
-
|
509
|
-
|
569
|
+
|
570
|
+
use_negative = false
|
571
|
+
if end_use_type == EUT::PV
|
572
|
+
use_negative = true
|
573
|
+
elsif (end_use_type == EUT::Generator) && (fuel_type == FT::Elec)
|
574
|
+
use_negative = true
|
575
|
+
end
|
576
|
+
|
577
|
+
end_use.annual_output = get_report_meter_data_annual(end_use.meters)
|
578
|
+
if use_negative && (@end_uses[key].annual_output > 0)
|
510
579
|
end_use.annual_output *= -1.0
|
511
580
|
end
|
512
581
|
next unless include_timeseries_end_use_consumptions
|
513
582
|
|
514
583
|
timeseries_unit_conv = UnitConversions.convert(1.0, 'J', end_use.timeseries_units)
|
515
|
-
if
|
584
|
+
if use_negative
|
516
585
|
timeseries_unit_conv *= -1.0
|
517
586
|
end
|
518
|
-
end_use.timeseries_output = get_report_meter_data_timeseries(
|
587
|
+
end_use.timeseries_output = get_report_meter_data_timeseries(end_use.meters, timeseries_unit_conv, 0, timeseries_frequency)
|
519
588
|
end
|
520
589
|
|
521
590
|
# Hot Water Uses
|
@@ -536,10 +605,9 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
536
605
|
# End Use
|
537
606
|
@fuels.each do |fuel_type, fuel|
|
538
607
|
end_use = @end_uses[[fuel_type, EUT::Heating]]
|
539
|
-
|
540
|
-
end_use.annual_output_by_system[sys_id] = get_report_variable_data_annual(keys, vars)
|
608
|
+
end_use.annual_output_by_system[sys_id] = get_report_variable_data_annual(keys, end_use.variable_names)
|
541
609
|
if include_timeseries_end_use_consumptions
|
542
|
-
end_use.timeseries_output_by_system[sys_id] = get_report_variable_data_timeseries(keys,
|
610
|
+
end_use.timeseries_output_by_system[sys_id] = get_report_variable_data_timeseries(keys, end_use.variable_names, UnitConversions.convert(1.0, 'J', end_use.timeseries_units), 0, timeseries_frequency)
|
543
611
|
end
|
544
612
|
end
|
545
613
|
|
@@ -563,10 +631,9 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
563
631
|
|
564
632
|
# End Uses
|
565
633
|
end_use = @end_uses[[FT::Elec, EUT::Cooling]]
|
566
|
-
|
567
|
-
end_use.annual_output_by_system[sys_id] = get_report_variable_data_annual(keys, vars)
|
634
|
+
end_use.annual_output_by_system[sys_id] = get_report_variable_data_annual(keys, end_use.variable_names)
|
568
635
|
if include_timeseries_end_use_consumptions
|
569
|
-
end_use.timeseries_output_by_system[sys_id] = get_report_variable_data_timeseries(keys,
|
636
|
+
end_use.timeseries_output_by_system[sys_id] = get_report_variable_data_timeseries(keys, end_use.variable_names, UnitConversions.convert(1.0, 'J', end_use.timeseries_units), 0, timeseries_frequency)
|
570
637
|
end
|
571
638
|
|
572
639
|
# Disaggregated Fan/Pump Energy Use
|
@@ -589,10 +656,9 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
589
656
|
|
590
657
|
@fuels.each do |fuel_type, fuel|
|
591
658
|
end_use = @end_uses[[fuel_type, EUT::MechVentPreheat]]
|
592
|
-
|
593
|
-
end_use.annual_output_by_system[sys_id] = get_report_variable_data_annual(keys, vars)
|
659
|
+
end_use.annual_output_by_system[sys_id] = get_report_variable_data_annual(keys, end_use.variable_names)
|
594
660
|
if include_timeseries_end_use_consumptions
|
595
|
-
end_use.timeseries_output_by_system[sys_id] = get_report_variable_data_timeseries(keys,
|
661
|
+
end_use.timeseries_output_by_system[sys_id] = get_report_variable_data_timeseries(keys, end_use.variable_names, UnitConversions.convert(1.0, 'J', end_use.timeseries_units), 0, timeseries_frequency)
|
596
662
|
end
|
597
663
|
end
|
598
664
|
end
|
@@ -603,22 +669,20 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
603
669
|
keys = ep_output_names.map(&:upcase)
|
604
670
|
|
605
671
|
end_use = @end_uses[[FT::Elec, EUT::MechVentPrecool]]
|
606
|
-
|
607
|
-
end_use.annual_output_by_system[sys_id] = get_report_variable_data_annual(keys, vars)
|
672
|
+
end_use.annual_output_by_system[sys_id] = get_report_variable_data_annual(keys, end_use.variable_names)
|
608
673
|
if include_timeseries_end_use_consumptions
|
609
|
-
end_use.timeseries_output_by_system[sys_id] = get_report_variable_data_timeseries(keys,
|
674
|
+
end_use.timeseries_output_by_system[sys_id] = get_report_variable_data_timeseries(keys, end_use.variable_names, UnitConversions.convert(1.0, 'J', end_use.timeseries_units), 0, timeseries_frequency)
|
610
675
|
end
|
611
676
|
end
|
612
677
|
|
613
678
|
# Dehumidifier
|
614
679
|
end_use = @end_uses[[FT::Elec, EUT::Dehumidifier]]
|
615
|
-
vars = get_all_var_keys(end_use.variable)
|
616
680
|
ep_output_name = @hvac_map[outputs[:hpxml_dehumidifier_id]]
|
617
681
|
if not ep_output_name.nil?
|
618
682
|
keys = ep_output_name.map(&:upcase)
|
619
|
-
end_use.annual_output = get_report_variable_data_annual(keys,
|
683
|
+
end_use.annual_output = get_report_variable_data_annual(keys, end_use.variable_names)
|
620
684
|
if include_timeseries_end_use_consumptions
|
621
|
-
end_use.timeseries_output = get_report_variable_data_timeseries(keys,
|
685
|
+
end_use.timeseries_output = get_report_variable_data_timeseries(keys, end_use.variable_names, UnitConversions.convert(1.0, 'J', end_use.timeseries_units), 0, timeseries_frequency)
|
622
686
|
end
|
623
687
|
else
|
624
688
|
end_use.annual_output = 0
|
@@ -638,17 +702,19 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
638
702
|
end_use = @end_uses[[fuel_type, end_use_type]]
|
639
703
|
next if end_use.nil?
|
640
704
|
|
641
|
-
|
642
|
-
|
643
|
-
end_use.annual_output_by_system[sys_id] = get_report_variable_data_annual(keys, vars)
|
705
|
+
end_use.annual_output_by_system[sys_id] = get_report_variable_data_annual(keys, end_use.variable_names)
|
644
706
|
if include_timeseries_end_use_consumptions
|
645
|
-
end_use.timeseries_output_by_system[sys_id] = get_report_variable_data_timeseries(keys,
|
707
|
+
end_use.timeseries_output_by_system[sys_id] = get_report_variable_data_timeseries(keys, end_use.variable_names, UnitConversions.convert(1.0, 'J', end_use.timeseries_units), 0, timeseries_frequency)
|
646
708
|
end
|
647
709
|
end
|
648
710
|
end
|
649
711
|
|
650
712
|
# Loads
|
651
|
-
|
713
|
+
load = @loads[LT::HotWaterDelivered]
|
714
|
+
load.annual_output_by_system[sys_id] = get_report_variable_data_annual(keys, load.variable_names)
|
715
|
+
if include_timeseries_total_loads
|
716
|
+
load.timeseries_output_by_system[sys_id] = get_report_variable_data_timeseries(keys, load.variable_names, UnitConversions.convert(1.0, 'J', load.timeseries_units), 0, timeseries_frequency)
|
717
|
+
end
|
652
718
|
|
653
719
|
# Combi boiler water system
|
654
720
|
hvac_id = get_combi_hvac_id(sys_id)
|
@@ -678,7 +744,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
678
744
|
@fuels.keys.reverse.each do |fuel_type| # Reverse so that FT::Elec is considered last
|
679
745
|
end_use = @end_uses[[fuel_type, EUT::HotWater]]
|
680
746
|
next if end_use.nil?
|
681
|
-
next if end_use.
|
747
|
+
next if end_use.variables.nil?
|
682
748
|
next unless end_use.annual_output_by_system[sys_id] > 0
|
683
749
|
|
684
750
|
ec_vars = ep_output_names.select { |name| name.include? Constants.ObjectNameWaterHeaterAdjustment(nil) }
|
@@ -724,11 +790,11 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
724
790
|
end
|
725
791
|
|
726
792
|
# Hot Water Load - Solar Thermal
|
727
|
-
@loads[LT::HotWaterSolarThermal].annual_output = get_report_variable_data_annual(solar_keys,
|
793
|
+
@loads[LT::HotWaterSolarThermal].annual_output = get_report_variable_data_annual(solar_keys, get_all_variable_keys(OutputVars.WaterHeaterLoadSolarThermal))
|
728
794
|
@loads[LT::HotWaterSolarThermal].annual_output *= -1 if @loads[LT::HotWaterSolarThermal].annual_output != 0
|
729
795
|
|
730
796
|
# Hot Water Load - Desuperheater
|
731
|
-
@loads[LT::HotWaterDesuperheater].annual_output = get_report_variable_data_annual(dsh_keys,
|
797
|
+
@loads[LT::HotWaterDesuperheater].annual_output = get_report_variable_data_annual(dsh_keys, @loads[LT::HotWaterDesuperheater].variable_names)
|
732
798
|
|
733
799
|
# Hot Water Load - Tank Losses (excluding solar storage tank)
|
734
800
|
@loads[LT::HotWaterTankLosses].annual_output = get_report_variable_data_annual(solar_keys, ['Water Heater Heat Loss Energy'], not_key: true)
|
@@ -819,11 +885,21 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
819
885
|
return false
|
820
886
|
end
|
821
887
|
|
888
|
+
# Check sum of electricity produced end use outputs match total
|
889
|
+
sum_elec_produced = -1 * (@end_uses[[FT::Elec, EUT::PV]].annual_output + @end_uses[[FT::Elec, EUT::Generator]].annual_output)
|
890
|
+
total_elec_produced = outputs[:total_elec_produced]
|
891
|
+
if (sum_elec_produced - total_elec_produced).abs > 0.1
|
892
|
+
runner.registerError("#{FT::Elec} produced category end uses (#{sum_elec_produced}) do not sum to total (#{total_elec_produced}).")
|
893
|
+
return false
|
894
|
+
end
|
895
|
+
|
822
896
|
# Check sum of end use outputs match fuel outputs
|
823
897
|
@fuels.keys.each do |fuel_type|
|
824
898
|
sum_categories = @end_uses.select { |k, eu| k[0] == fuel_type }.map { |k, eu| eu.annual_output }.sum(0.0)
|
825
899
|
fuel_total = @fuels[fuel_type].annual_output
|
826
|
-
|
900
|
+
if fuel_type == FT::Elec
|
901
|
+
fuel_total -= sum_elec_produced
|
902
|
+
end
|
827
903
|
if (fuel_total - sum_categories).abs > 0.1
|
828
904
|
runner.registerError("#{fuel_type} category end uses (#{sum_categories}) do not sum to total (#{fuel_total}).")
|
829
905
|
return false
|
@@ -834,7 +910,8 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
834
910
|
{ @end_uses => 'End Use',
|
835
911
|
@fuels => 'Fuel',
|
836
912
|
@loads => 'Load',
|
837
|
-
@component_loads => 'Component Load'
|
913
|
+
@component_loads => 'Component Load',
|
914
|
+
@unmet_loads => 'Unmet Load' }.each do |outputs, output_type|
|
838
915
|
outputs.each do |key, obj|
|
839
916
|
next if obj.timeseries_output.empty?
|
840
917
|
|
@@ -850,15 +927,16 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
850
927
|
return true
|
851
928
|
end
|
852
929
|
|
853
|
-
def write_annual_output_results(runner, outputs,
|
930
|
+
def write_annual_output_results(runner, outputs, output_format, annual_output_path)
|
854
931
|
line_break = nil
|
855
|
-
|
932
|
+
elec_pv_produced = @end_uses[[FT::Elec, EUT::PV]]
|
933
|
+
elec_generator_produced = @end_uses[[FT::Elec, EUT::Generator]]
|
856
934
|
|
857
935
|
results_out = []
|
858
936
|
@fuels.each do |fuel_type, fuel|
|
859
937
|
results_out << ["#{fuel.name} (#{fuel.annual_units})", fuel.annual_output.round(2)]
|
860
938
|
if fuel_type == FT::Elec
|
861
|
-
results_out << ['Electricity: Net (MBtu)', (fuel.annual_output +
|
939
|
+
results_out << ['Fuel Use: Electricity: Net (MBtu)', (fuel.annual_output + elec_pv_produced.annual_output + elec_generator_produced.annual_output).round(2)]
|
862
940
|
end
|
863
941
|
end
|
864
942
|
results_out << [line_break]
|
@@ -875,23 +953,39 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
875
953
|
end
|
876
954
|
results_out << [line_break]
|
877
955
|
@peak_fuels.each do |key, peak_fuel|
|
878
|
-
results_out << ["#{peak_fuel.name} (#{peak_fuel.annual_units})", peak_fuel.annual_output.round(
|
956
|
+
results_out << ["#{peak_fuel.name} (#{peak_fuel.annual_units})", peak_fuel.annual_output.round(0)]
|
879
957
|
end
|
880
958
|
results_out << [line_break]
|
881
959
|
@peak_loads.each do |load_type, peak_load|
|
882
960
|
results_out << ["#{peak_load.name} (#{peak_load.annual_units})", peak_load.annual_output.round(2)]
|
883
961
|
end
|
884
|
-
|
885
|
-
|
886
|
-
|
962
|
+
if @component_loads.values.map { |load| load.annual_output }.sum > 0 # Skip if component loads not calculated
|
963
|
+
results_out << [line_break]
|
964
|
+
@component_loads.each do |load_type, load|
|
965
|
+
results_out << ["#{load.name} (#{load.annual_units})", load.annual_output.round(2)]
|
966
|
+
end
|
887
967
|
end
|
888
968
|
results_out << [line_break]
|
889
969
|
@hot_water_uses.each do |hot_water_type, hot_water|
|
890
|
-
results_out << ["#{hot_water.name} (#{hot_water.annual_units})", hot_water.annual_output.round(
|
970
|
+
results_out << ["#{hot_water.name} (#{hot_water.annual_units})", hot_water.annual_output.round(0)]
|
891
971
|
end
|
892
972
|
|
893
|
-
|
894
|
-
|
973
|
+
if output_format == 'csv'
|
974
|
+
CSV.open(annual_output_path, 'wb') { |csv| results_out.to_a.each { |elem| csv << elem } }
|
975
|
+
elsif output_format == 'json'
|
976
|
+
h = {}
|
977
|
+
results_out.each do |out|
|
978
|
+
next if out == [line_break]
|
979
|
+
|
980
|
+
grp, name = out[0].split(':', 2)
|
981
|
+
h[grp] = {} if h[grp].nil?
|
982
|
+
h[grp][name.strip] = out[1]
|
983
|
+
end
|
984
|
+
|
985
|
+
require 'json'
|
986
|
+
File.open(annual_output_path, 'w') { |json| json.write(JSON.pretty_generate(h)) }
|
987
|
+
end
|
988
|
+
runner.registerInfo("Wrote annual output results to #{annual_output_path}.")
|
895
989
|
end
|
896
990
|
|
897
991
|
def report_sim_outputs(outputs, runner)
|
@@ -1014,16 +1108,20 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1014
1108
|
results_out << ['hpxml_cfa', outputs[:hpxml_cfa].to_s]
|
1015
1109
|
results_out << ['hpxml_nbr', outputs[:hpxml_nbr].to_s]
|
1016
1110
|
results_out << ['hpxml_nst', outputs[:hpxml_nst].to_s]
|
1111
|
+
results_out << ['hpxml_residential_facility_type', '"' + outputs[:hpxml_residential_facility_type] + '"']
|
1017
1112
|
|
1018
1113
|
CSV.open(csv_path, 'wb') { |csv| results_out.to_a.each { |elem| csv << elem } }
|
1019
1114
|
end
|
1020
1115
|
|
1021
|
-
def write_timeseries_output_results(runner,
|
1116
|
+
def write_timeseries_output_results(runner, output_format,
|
1117
|
+
timeseries_output_path,
|
1118
|
+
timeseries_frequency,
|
1022
1119
|
include_timeseries_fuel_consumptions,
|
1023
1120
|
include_timeseries_end_use_consumptions,
|
1024
1121
|
include_timeseries_hot_water_uses,
|
1025
1122
|
include_timeseries_total_loads,
|
1026
1123
|
include_timeseries_component_loads,
|
1124
|
+
include_timeseries_unmet_loads,
|
1027
1125
|
include_timeseries_zone_temperatures,
|
1028
1126
|
include_timeseries_airflows,
|
1029
1127
|
include_timeseries_weather)
|
@@ -1064,6 +1162,11 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1064
1162
|
else
|
1065
1163
|
comp_loads_data = []
|
1066
1164
|
end
|
1165
|
+
if include_timeseries_unmet_loads
|
1166
|
+
unmet_loads_data = @unmet_loads.values.select { |x| !x.timeseries_output.empty? }.map { |x| [x.name, x.timeseries_units] + x.timeseries_output.map { |v| v.round(2) } }
|
1167
|
+
else
|
1168
|
+
unmet_loads_data = []
|
1169
|
+
end
|
1067
1170
|
if include_timeseries_zone_temperatures
|
1068
1171
|
zone_temps_data = @zone_temps.values.select { |x| !x.timeseries_output.empty? }.map { |x| [x.name, x.timeseries_units] + x.timeseries_output.map { |v| v.round(2) } }
|
1069
1172
|
else
|
@@ -1080,25 +1183,42 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1080
1183
|
weather_data = []
|
1081
1184
|
end
|
1082
1185
|
|
1083
|
-
return if fuel_data.size + end_use_data.size + hot_water_use_data.size + total_loads_data.size + comp_loads_data.size + zone_temps_data.size + airflows_data.size + weather_data.size == 0
|
1186
|
+
return if fuel_data.size + end_use_data.size + hot_water_use_data.size + total_loads_data.size + comp_loads_data.size + unmet_loads_data.size + zone_temps_data.size + airflows_data.size + weather_data.size == 0
|
1084
1187
|
|
1085
1188
|
fail 'Unable to obtain timestamps.' if @timestamps.empty?
|
1086
1189
|
|
1087
|
-
|
1088
|
-
|
1190
|
+
if output_format == 'csv'
|
1191
|
+
# Assemble data
|
1192
|
+
data = data.zip(*fuel_data, *end_use_data, *hot_water_use_data, *total_loads_data, *comp_loads_data, *unmet_loads_data, *zone_temps_data, *airflows_data, *weather_data)
|
1193
|
+
|
1194
|
+
# Error-check
|
1195
|
+
n_elements = []
|
1196
|
+
data.each do |data_array|
|
1197
|
+
n_elements << data_array.size
|
1198
|
+
end
|
1199
|
+
if n_elements.uniq.size > 1
|
1200
|
+
fail "Inconsistent number of array elements: #{n_elements.uniq}."
|
1201
|
+
end
|
1202
|
+
|
1203
|
+
# Write file
|
1204
|
+
CSV.open(timeseries_output_path, 'wb') { |csv| data.to_a.each { |elem| csv << elem } }
|
1205
|
+
elsif output_format == 'json'
|
1206
|
+
# Assemble data
|
1207
|
+
h = {}
|
1208
|
+
h['Time'] = data[2..-1]
|
1209
|
+
[fuel_data, end_use_data, hot_water_use_data, total_loads_data, comp_loads_data, unmet_loads_data, zone_temps_data, airflows_data, weather_data].each do |d|
|
1210
|
+
d.each do |o|
|
1211
|
+
grp, name = o[0].split(':', 2)
|
1212
|
+
h[grp] = {} if h[grp].nil?
|
1213
|
+
h[grp]["#{name.strip} (#{o[1]})"] = o[2..-1]
|
1214
|
+
end
|
1215
|
+
end
|
1089
1216
|
|
1090
|
-
|
1091
|
-
|
1092
|
-
|
1093
|
-
n_elements << data_array.size
|
1217
|
+
# Write file
|
1218
|
+
require 'json'
|
1219
|
+
File.open(timeseries_output_path, 'w') { |json| json.write(JSON.pretty_generate(h)) }
|
1094
1220
|
end
|
1095
|
-
|
1096
|
-
fail "Inconsistent number of array elements: #{n_elements.uniq}."
|
1097
|
-
end
|
1098
|
-
|
1099
|
-
# Write file
|
1100
|
-
CSV.open(csv_path, 'wb') { |csv| data.to_a.each { |elem| csv << elem } }
|
1101
|
-
runner.registerInfo("Wrote timeseries output results to #{csv_path}.")
|
1221
|
+
runner.registerInfo("Wrote timeseries output results to #{timeseries_output_path}.")
|
1102
1222
|
end
|
1103
1223
|
|
1104
1224
|
def get_hpxml_dse_heats(heat_sys_ids)
|
@@ -1376,6 +1496,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1376
1496
|
@hpxml.water_heating_systems.each do |dhw_system|
|
1377
1497
|
sys_id = dhw_system.id
|
1378
1498
|
value = dhw_system.energy_factor
|
1499
|
+
value = dhw_system.uniform_energy_factor if value.nil?
|
1379
1500
|
wh_type = dhw_system.water_heater_type
|
1380
1501
|
if wh_type == HPXML::WaterHeaterTypeTankless
|
1381
1502
|
value_adj = dhw_system.performance_adjustment
|
@@ -1384,6 +1505,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1384
1505
|
end
|
1385
1506
|
|
1386
1507
|
if value.nil?
|
1508
|
+
# Get assumed EF for combi system
|
1387
1509
|
@model.getWaterHeaterMixeds.each do |wh|
|
1388
1510
|
next unless @dhw_map[sys_id].include? wh.name.to_s
|
1389
1511
|
|
@@ -1443,17 +1565,18 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1443
1565
|
return sys.id
|
1444
1566
|
end
|
1445
1567
|
|
1446
|
-
def get_report_meter_data_annual(
|
1447
|
-
|
1568
|
+
def get_report_meter_data_annual(meter_names, unit_conv = UnitConversions.convert(1.0, 'J', 'MBtu'))
|
1569
|
+
vars = "'" + meter_names.join("','") + "'"
|
1570
|
+
query = "SELECT SUM(VariableValue*#{unit_conv}) FROM ReportMeterData WHERE ReportMeterDataDictionaryIndex IN (SELECT ReportMeterDataDictionaryIndex FROM ReportMeterDataDictionary WHERE VariableName IN (#{vars}) AND ReportingFrequency='Run Period' AND VariableUnits='J')"
|
1448
1571
|
value = @sqlFile.execAndReturnFirstDouble(query)
|
1449
1572
|
fail "Query error: #{query}" unless value.is_initialized
|
1450
1573
|
|
1451
1574
|
return value.get
|
1452
1575
|
end
|
1453
1576
|
|
1454
|
-
def get_report_variable_data_annual(
|
1455
|
-
keys = "'" +
|
1456
|
-
vars = "'" +
|
1577
|
+
def get_report_variable_data_annual(key_values, variable_names, unit_conv = UnitConversions.convert(1.0, 'J', 'MBtu'), not_key: false)
|
1578
|
+
keys = "'" + key_values.join("','") + "'"
|
1579
|
+
vars = "'" + variable_names.join("','") + "'"
|
1457
1580
|
if not_key
|
1458
1581
|
s_not = 'NOT '
|
1459
1582
|
else
|
@@ -1466,8 +1589,9 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1466
1589
|
return value.get
|
1467
1590
|
end
|
1468
1591
|
|
1469
|
-
def get_report_meter_data_timeseries(
|
1470
|
-
|
1592
|
+
def get_report_meter_data_timeseries(meter_names, unit_conv, unit_adder, timeseries_frequency)
|
1593
|
+
vars = "'" + meter_names.join("','") + "'"
|
1594
|
+
query = "SELECT SUM(VariableValue*#{unit_conv}+#{unit_adder}) FROM ReportMeterData WHERE ReportMeterDataDictionaryIndex IN (SELECT ReportMeterDataDictionaryIndex FROM ReportMeterDataDictionary WHERE VariableName IN (#{vars}) AND ReportingFrequency='#{reporting_frequency_map[timeseries_frequency]}' AND VariableUnits='J') GROUP BY TimeIndex ORDER BY TimeIndex"
|
1471
1595
|
values = @sqlFile.execAndReturnVectorOfDouble(query)
|
1472
1596
|
fail "Query error: #{query}" unless values.is_initialized
|
1473
1597
|
|
@@ -1476,9 +1600,9 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1476
1600
|
return values
|
1477
1601
|
end
|
1478
1602
|
|
1479
|
-
def get_report_variable_data_timeseries(
|
1480
|
-
keys = "'" +
|
1481
|
-
vars = "'" +
|
1603
|
+
def get_report_variable_data_timeseries(key_values, variable_names, unit_conv, unit_adder, timeseries_frequency, disable_ems_shift = false)
|
1604
|
+
keys = "'" + key_values.join("','") + "'"
|
1605
|
+
vars = "'" + variable_names.join("','") + "'"
|
1482
1606
|
query = "SELECT SUM(VariableValue*#{unit_conv}+#{unit_adder}) FROM ReportVariableData WHERE ReportVariableDataDictionaryIndex IN (SELECT ReportVariableDataDictionaryIndex FROM ReportVariableDataDictionary WHERE KeyValue IN (#{keys}) AND VariableName IN (#{vars}) AND ReportingFrequency='#{reporting_frequency_map[timeseries_frequency]}') GROUP BY TimeIndex ORDER BY TimeIndex"
|
1483
1607
|
values = @sqlFile.execAndReturnVectorOfDouble(query)
|
1484
1608
|
fail "Query error: #{query}" unless values.is_initialized
|
@@ -1488,7 +1612,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1488
1612
|
|
1489
1613
|
return values if disable_ems_shift
|
1490
1614
|
|
1491
|
-
if (
|
1615
|
+
if (key_values.size == 1) && (key_values[0] == 'EMS') && (@timestamps.size > 0)
|
1492
1616
|
if (timeseries_frequency.downcase == 'timestep' || (timeseries_frequency.downcase == 'hourly' && @model.getTimestep.numberOfTimestepsPerHour == 1))
|
1493
1617
|
# Shift all values by 1 timestep due to EMS reporting lag
|
1494
1618
|
return values[1..-1] + [values[-1]]
|
@@ -1498,8 +1622,9 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1498
1622
|
return values
|
1499
1623
|
end
|
1500
1624
|
|
1501
|
-
def get_tabular_data_value(report_name, report_for_string, table_name,
|
1502
|
-
|
1625
|
+
def get_tabular_data_value(report_name, report_for_string, table_name, row_names, col_name, units)
|
1626
|
+
rows = "'" + row_names.join("','") + "'"
|
1627
|
+
query = "SELECT SUM(Value) FROM TabularDataWithStrings WHERE ReportName='#{report_name}' AND ReportForString='#{report_for_string}' AND TableName='#{table_name}' AND RowName IN (#{rows}) AND ColumnName='#{col_name}' AND Units='#{units}'"
|
1503
1628
|
result = @sqlFile.execAndReturnFirstDouble(query)
|
1504
1629
|
return result.get
|
1505
1630
|
end
|
@@ -1543,9 +1668,9 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1543
1668
|
next unless dfhp_primary || dfhp_backup
|
1544
1669
|
|
1545
1670
|
if dfhp_primary
|
1546
|
-
vars =
|
1671
|
+
vars = get_all_variable_keys(OutputVars.SpaceHeatingDFHPPrimaryLoad)
|
1547
1672
|
else
|
1548
|
-
vars =
|
1673
|
+
vars = get_all_variable_keys(OutputVars.SpaceHeatingDFHPBackupLoad)
|
1549
1674
|
sys_id = dfhp_primary_sys_id(sys_id)
|
1550
1675
|
end
|
1551
1676
|
dfhp_loads[[sys_id, dfhp_primary]] = get_report_variable_data_annual(keys, vars)
|
@@ -1613,16 +1738,6 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1613
1738
|
return false
|
1614
1739
|
end
|
1615
1740
|
|
1616
|
-
def get_all_var_keys(var)
|
1617
|
-
var_keys = []
|
1618
|
-
var.keys.each do |key|
|
1619
|
-
var[key].each do |var_key|
|
1620
|
-
var_keys << var_key
|
1621
|
-
end
|
1622
|
-
end
|
1623
|
-
return var_keys
|
1624
|
-
end
|
1625
|
-
|
1626
1741
|
def get_dhw_solar_fraction(sys_id)
|
1627
1742
|
solar_fraction = 0.0
|
1628
1743
|
if @hpxml.solar_thermal_systems.size > 0
|
@@ -1699,34 +1814,34 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1699
1814
|
end
|
1700
1815
|
|
1701
1816
|
def add_object_output_variables(timeseries_frequency)
|
1702
|
-
hvac_output_vars = [OutputVars.
|
1703
|
-
OutputVars.
|
1704
|
-
OutputVars.
|
1705
|
-
OutputVars.
|
1706
|
-
OutputVars.
|
1707
|
-
OutputVars.
|
1708
|
-
OutputVars.
|
1817
|
+
hvac_output_vars = [OutputVars.SpaceHeating(EPlus::FuelTypeElectricity),
|
1818
|
+
OutputVars.SpaceHeating(EPlus::FuelTypeNaturalGas),
|
1819
|
+
OutputVars.SpaceHeating(EPlus::FuelTypeOil),
|
1820
|
+
OutputVars.SpaceHeating(EPlus::FuelTypePropane),
|
1821
|
+
OutputVars.SpaceHeating(EPlus::FuelTypeWoodCord),
|
1822
|
+
OutputVars.SpaceHeating(EPlus::FuelTypeWoodPellets),
|
1823
|
+
OutputVars.SpaceHeating(EPlus::FuelTypeCoal),
|
1709
1824
|
OutputVars.SpaceHeatingDFHPPrimaryLoad,
|
1710
1825
|
OutputVars.SpaceHeatingDFHPBackupLoad,
|
1711
1826
|
OutputVars.SpaceCoolingElectricity,
|
1712
1827
|
OutputVars.DehumidifierElectricity,
|
1713
|
-
OutputVars.
|
1714
|
-
OutputVars.
|
1715
|
-
OutputVars.
|
1716
|
-
OutputVars.
|
1717
|
-
OutputVars.
|
1718
|
-
OutputVars.
|
1719
|
-
OutputVars.
|
1720
|
-
|
1721
|
-
dhw_output_vars = [OutputVars.
|
1828
|
+
OutputVars.MechVentPreconditioning(EPlus::FuelTypeElectricity),
|
1829
|
+
OutputVars.MechVentPreconditioning(EPlus::FuelTypeNaturalGas),
|
1830
|
+
OutputVars.MechVentPreconditioning(EPlus::FuelTypeOil),
|
1831
|
+
OutputVars.MechVentPreconditioning(EPlus::FuelTypePropane),
|
1832
|
+
OutputVars.MechVentPreconditioning(EPlus::FuelTypeWoodCord),
|
1833
|
+
OutputVars.MechVentPreconditioning(EPlus::FuelTypeWoodPellets),
|
1834
|
+
OutputVars.MechVentPreconditioning(EPlus::FuelTypeCoal)]
|
1835
|
+
|
1836
|
+
dhw_output_vars = [OutputVars.WaterHeating(EPlus::FuelTypeElectricity),
|
1837
|
+
OutputVars.WaterHeating(EPlus::FuelTypeNaturalGas),
|
1838
|
+
OutputVars.WaterHeating(EPlus::FuelTypeOil),
|
1839
|
+
OutputVars.WaterHeating(EPlus::FuelTypePropane),
|
1840
|
+
OutputVars.WaterHeating(EPlus::FuelTypeWoodCord),
|
1841
|
+
OutputVars.WaterHeating(EPlus::FuelTypeWoodPellets),
|
1842
|
+
OutputVars.WaterHeating(EPlus::FuelTypeCoal),
|
1722
1843
|
OutputVars.WaterHeatingElectricityRecircPump,
|
1723
1844
|
OutputVars.WaterHeatingElectricitySolarThermalPump,
|
1724
|
-
OutputVars.WaterHeatingFuel(EPlus::FuelTypeNaturalGas),
|
1725
|
-
OutputVars.WaterHeatingFuel(EPlus::FuelTypeOil),
|
1726
|
-
OutputVars.WaterHeatingFuel(EPlus::FuelTypePropane),
|
1727
|
-
OutputVars.WaterHeatingFuel(EPlus::FuelTypeWoodCord),
|
1728
|
-
OutputVars.WaterHeatingFuel(EPlus::FuelTypeWoodPellets),
|
1729
|
-
OutputVars.WaterHeatingFuel(EPlus::FuelTypeCoal),
|
1730
1845
|
OutputVars.WaterHeatingLoad,
|
1731
1846
|
OutputVars.WaterHeatingLoadTankLosses,
|
1732
1847
|
OutputVars.WaterHeaterLoadDesuperheater,
|
@@ -1837,23 +1952,26 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1837
1952
|
end
|
1838
1953
|
|
1839
1954
|
class Fuel < BaseOutput
|
1840
|
-
def initialize(
|
1955
|
+
def initialize(meters: nil)
|
1841
1956
|
super()
|
1842
|
-
@
|
1957
|
+
@meters = meters
|
1843
1958
|
@timeseries_output_by_system = {}
|
1844
1959
|
end
|
1845
|
-
attr_accessor(:
|
1960
|
+
attr_accessor(:meters, :timeseries_output_by_system)
|
1846
1961
|
end
|
1847
1962
|
|
1848
1963
|
class EndUse < BaseOutput
|
1849
|
-
def initialize(
|
1964
|
+
def initialize(meters: nil, variables: nil)
|
1850
1965
|
super()
|
1851
|
-
@
|
1852
|
-
@
|
1966
|
+
@meters = meters
|
1967
|
+
@variables = variables
|
1853
1968
|
@timeseries_output_by_system = {}
|
1854
1969
|
@annual_output_by_system = {}
|
1970
|
+
if not variables.nil?
|
1971
|
+
@variable_names = get_all_variable_keys(variables)
|
1972
|
+
end
|
1855
1973
|
end
|
1856
|
-
attr_accessor(:
|
1974
|
+
attr_accessor(:meters, :variables, :annual_output_by_system, :timeseries_output_by_system, :variable_names)
|
1857
1975
|
end
|
1858
1976
|
|
1859
1977
|
class HotWater < BaseOutput
|
@@ -1865,23 +1983,26 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1865
1983
|
end
|
1866
1984
|
|
1867
1985
|
class PeakFuel < BaseOutput
|
1868
|
-
def initialize(
|
1986
|
+
def initialize(meters:, report:)
|
1869
1987
|
super()
|
1870
|
-
@
|
1988
|
+
@meters = meters
|
1871
1989
|
@report = report
|
1872
1990
|
end
|
1873
|
-
attr_accessor(:
|
1991
|
+
attr_accessor(:meters, :report)
|
1874
1992
|
end
|
1875
1993
|
|
1876
1994
|
class Load < BaseOutput
|
1877
|
-
def initialize(
|
1995
|
+
def initialize(variables: nil, ems_variable: nil)
|
1878
1996
|
super()
|
1879
|
-
@
|
1997
|
+
@variables = variables
|
1880
1998
|
@ems_variable = ems_variable
|
1881
1999
|
@timeseries_output_by_system = {}
|
1882
2000
|
@annual_output_by_system = {}
|
2001
|
+
if not variables.nil?
|
2002
|
+
@variable_names = get_all_variable_keys(variables)
|
2003
|
+
end
|
1883
2004
|
end
|
1884
|
-
attr_accessor(:
|
2005
|
+
attr_accessor(:variables, :ems_variable, :annual_output_by_system, :timeseries_output_by_system, :variable_names)
|
1885
2006
|
end
|
1886
2007
|
|
1887
2008
|
class ComponentLoad < BaseOutput
|
@@ -1902,11 +2023,11 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1902
2023
|
end
|
1903
2024
|
|
1904
2025
|
class PeakLoad < BaseOutput
|
1905
|
-
def initialize(
|
2026
|
+
def initialize(meters:)
|
1906
2027
|
super()
|
1907
|
-
@
|
2028
|
+
@meters = meters
|
1908
2029
|
end
|
1909
|
-
attr_accessor(:
|
2030
|
+
attr_accessor(:meters)
|
1910
2031
|
end
|
1911
2032
|
|
1912
2033
|
class ZoneTemp < BaseOutput
|
@@ -1944,26 +2065,19 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1944
2065
|
return 'kBtu'
|
1945
2066
|
end
|
1946
2067
|
|
1947
|
-
ep_fuel_names = { FT::Gas => EPlus.output_fuel_map(EPlus::FuelTypeNaturalGas),
|
1948
|
-
FT::Oil => EPlus.output_fuel_map(EPlus::FuelTypeOil),
|
1949
|
-
FT::Propane => EPlus.output_fuel_map(EPlus::FuelTypePropane),
|
1950
|
-
FT::WoodCord => EPlus.output_fuel_map(EPlus::FuelTypeWoodCord),
|
1951
|
-
FT::WoodPellets => EPlus.output_fuel_map(EPlus::FuelTypeWoodPellets),
|
1952
|
-
FT::Coal => EPlus.output_fuel_map(EPlus::FuelTypeCoal) }
|
1953
|
-
|
1954
2068
|
# Fuels
|
1955
2069
|
|
1956
2070
|
@fuels = {}
|
1957
|
-
@fuels[FT::Elec] = Fuel.new(
|
1958
|
-
@fuels[FT::Gas] = Fuel.new(
|
1959
|
-
@fuels[FT::Oil] = Fuel.new(
|
1960
|
-
@fuels[FT::Propane] = Fuel.new(
|
1961
|
-
@fuels[FT::WoodCord] = Fuel.new(
|
1962
|
-
@fuels[FT::WoodPellets] = Fuel.new(
|
1963
|
-
@fuels[FT::Coal] = Fuel.new(
|
2071
|
+
@fuels[FT::Elec] = Fuel.new(meters: ["#{EPlus::FuelTypeElectricity}:Facility"])
|
2072
|
+
@fuels[FT::Gas] = Fuel.new(meters: ["#{EPlus::FuelTypeNaturalGas}:Facility"])
|
2073
|
+
@fuels[FT::Oil] = Fuel.new(meters: ["#{EPlus::FuelTypeOil}:Facility"])
|
2074
|
+
@fuels[FT::Propane] = Fuel.new(meters: ["#{EPlus::FuelTypePropane}:Facility"])
|
2075
|
+
@fuels[FT::WoodCord] = Fuel.new(meters: ["#{EPlus::FuelTypeWoodCord}:Facility"])
|
2076
|
+
@fuels[FT::WoodPellets] = Fuel.new(meters: ["#{EPlus::FuelTypeWoodPellets}:Facility"])
|
2077
|
+
@fuels[FT::Coal] = Fuel.new(meters: ["#{EPlus::FuelTypeCoal}:Facility"])
|
1964
2078
|
|
1965
2079
|
@fuels.each do |fuel_type, fuel|
|
1966
|
-
fuel.name = "#{fuel_type}: Total"
|
2080
|
+
fuel.name = "Fuel Use: #{fuel_type}: Total"
|
1967
2081
|
fuel.annual_units = 'MBtu'
|
1968
2082
|
fuel.timeseries_units = get_timeseries_units_from_fuel_type(fuel_type)
|
1969
2083
|
end
|
@@ -1973,107 +2087,114 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
1973
2087
|
# NOTE: Some end uses are obtained from meters, others are rolled up from
|
1974
2088
|
# output variables so that we can have more control.
|
1975
2089
|
@end_uses = {}
|
1976
|
-
@end_uses[[FT::Elec, EUT::Heating]] = EndUse.new(
|
2090
|
+
@end_uses[[FT::Elec, EUT::Heating]] = EndUse.new(variables: OutputVars.SpaceHeating(EPlus::FuelTypeElectricity))
|
1977
2091
|
@end_uses[[FT::Elec, EUT::HeatingFanPump]] = EndUse.new()
|
1978
|
-
@end_uses[[FT::Elec, EUT::Cooling]] = EndUse.new(
|
2092
|
+
@end_uses[[FT::Elec, EUT::Cooling]] = EndUse.new(variables: OutputVars.SpaceCoolingElectricity)
|
1979
2093
|
@end_uses[[FT::Elec, EUT::CoolingFanPump]] = EndUse.new()
|
1980
|
-
@end_uses[[FT::Elec, EUT::HotWater]] = EndUse.new(
|
1981
|
-
@end_uses[[FT::Elec, EUT::HotWaterRecircPump]] = EndUse.new(
|
1982
|
-
@end_uses[[FT::Elec, EUT::HotWaterSolarThermalPump]] = EndUse.new(
|
1983
|
-
@end_uses[[FT::Elec, EUT::LightsInterior]] = EndUse.new(
|
1984
|
-
@end_uses[[FT::Elec, EUT::LightsGarage]] = EndUse.new(
|
1985
|
-
@end_uses[[FT::Elec, EUT::LightsExterior]] = EndUse.new(
|
1986
|
-
@end_uses[[FT::Elec, EUT::MechVent]] = EndUse.new(
|
1987
|
-
@end_uses[[FT::Elec, EUT::MechVentPreheat]] = EndUse.new(
|
1988
|
-
@end_uses[[FT::Elec, EUT::MechVentPrecool]] = EndUse.new(
|
1989
|
-
@end_uses[[FT::Elec, EUT::WholeHouseFan]] = EndUse.new(
|
1990
|
-
@end_uses[[FT::Elec, EUT::Refrigerator]] = EndUse.new(
|
2094
|
+
@end_uses[[FT::Elec, EUT::HotWater]] = EndUse.new(variables: OutputVars.WaterHeating(EPlus::FuelTypeElectricity))
|
2095
|
+
@end_uses[[FT::Elec, EUT::HotWaterRecircPump]] = EndUse.new(variables: OutputVars.WaterHeatingElectricityRecircPump)
|
2096
|
+
@end_uses[[FT::Elec, EUT::HotWaterSolarThermalPump]] = EndUse.new(variables: OutputVars.WaterHeatingElectricitySolarThermalPump)
|
2097
|
+
@end_uses[[FT::Elec, EUT::LightsInterior]] = EndUse.new(meters: ["#{Constants.ObjectNameInteriorLighting}:InteriorLights:#{EPlus::FuelTypeElectricity}"])
|
2098
|
+
@end_uses[[FT::Elec, EUT::LightsGarage]] = EndUse.new(meters: ["#{Constants.ObjectNameGarageLighting}:InteriorLights:#{EPlus::FuelTypeElectricity}"])
|
2099
|
+
@end_uses[[FT::Elec, EUT::LightsExterior]] = EndUse.new(meters: ["ExteriorLights:#{EPlus::FuelTypeElectricity}"])
|
2100
|
+
@end_uses[[FT::Elec, EUT::MechVent]] = EndUse.new(meters: ["#{Constants.ObjectNameMechanicalVentilation}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2101
|
+
@end_uses[[FT::Elec, EUT::MechVentPreheat]] = EndUse.new(variables: OutputVars.MechVentPreconditioning(EPlus::FuelTypeElectricity))
|
2102
|
+
@end_uses[[FT::Elec, EUT::MechVentPrecool]] = EndUse.new(variables: OutputVars.MechVentPreconditioning(EPlus::FuelTypeElectricity))
|
2103
|
+
@end_uses[[FT::Elec, EUT::WholeHouseFan]] = EndUse.new(meters: ["#{Constants.ObjectNameWholeHouseFan}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2104
|
+
@end_uses[[FT::Elec, EUT::Refrigerator]] = EndUse.new(meters: ["#{Constants.ObjectNameRefrigerator}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
1991
2105
|
if @eri_design.nil? # Skip end uses not used by ERI
|
1992
|
-
@end_uses[[FT::Elec, EUT::Freezer]] = EndUse.new(
|
1993
|
-
end
|
1994
|
-
@end_uses[[FT::Elec, EUT::Dehumidifier]] = EndUse.new(
|
1995
|
-
@end_uses[[FT::Elec, EUT::Dishwasher]] = EndUse.new(
|
1996
|
-
@end_uses[[FT::Elec, EUT::ClothesWasher]] = EndUse.new(
|
1997
|
-
@end_uses[[FT::Elec, EUT::ClothesDryer]] = EndUse.new(
|
1998
|
-
@end_uses[[FT::Elec, EUT::RangeOven]] = EndUse.new(
|
1999
|
-
@end_uses[[FT::Elec, EUT::CeilingFan]] = EndUse.new(
|
2000
|
-
@end_uses[[FT::Elec, EUT::Television]] = EndUse.new(
|
2001
|
-
@end_uses[[FT::Elec, EUT::PlugLoads]] = EndUse.new(
|
2106
|
+
@end_uses[[FT::Elec, EUT::Freezer]] = EndUse.new(meters: ["#{Constants.ObjectNameFreezer}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2107
|
+
end
|
2108
|
+
@end_uses[[FT::Elec, EUT::Dehumidifier]] = EndUse.new(variables: OutputVars.DehumidifierElectricity)
|
2109
|
+
@end_uses[[FT::Elec, EUT::Dishwasher]] = EndUse.new(meters: ["#{Constants.ObjectNameDishwasher}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2110
|
+
@end_uses[[FT::Elec, EUT::ClothesWasher]] = EndUse.new(meters: ["#{Constants.ObjectNameClothesWasher}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2111
|
+
@end_uses[[FT::Elec, EUT::ClothesDryer]] = EndUse.new(meters: ["#{Constants.ObjectNameClothesDryer}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2112
|
+
@end_uses[[FT::Elec, EUT::RangeOven]] = EndUse.new(meters: ["#{Constants.ObjectNameCookingRange}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2113
|
+
@end_uses[[FT::Elec, EUT::CeilingFan]] = EndUse.new(meters: ["#{Constants.ObjectNameCeilingFan}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2114
|
+
@end_uses[[FT::Elec, EUT::Television]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscTelevision}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2115
|
+
@end_uses[[FT::Elec, EUT::PlugLoads]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscPlugLoads}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2002
2116
|
if @eri_design.nil? # Skip end uses not used by ERI
|
2003
|
-
@end_uses[[FT::Elec, EUT::Vehicle]] = EndUse.new(
|
2004
|
-
@end_uses[[FT::Elec, EUT::WellPump]] = EndUse.new(
|
2005
|
-
@end_uses[[FT::Elec, EUT::PoolHeater]] = EndUse.new(
|
2006
|
-
@end_uses[[FT::Elec, EUT::PoolPump]] = EndUse.new(
|
2007
|
-
@end_uses[[FT::Elec, EUT::HotTubHeater]] = EndUse.new(
|
2008
|
-
@end_uses[[FT::Elec, EUT::HotTubPump]] = EndUse.new(
|
2009
|
-
end
|
2010
|
-
@end_uses[[FT::Elec, EUT::PV]] = EndUse.new(
|
2011
|
-
@end_uses[[FT::
|
2012
|
-
@end_uses[[FT::Gas, EUT::
|
2013
|
-
@end_uses[[FT::Gas, EUT::
|
2014
|
-
@end_uses[[FT::Gas, EUT::
|
2015
|
-
@end_uses[[FT::Gas, EUT::
|
2117
|
+
@end_uses[[FT::Elec, EUT::Vehicle]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscElectricVehicleCharging}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2118
|
+
@end_uses[[FT::Elec, EUT::WellPump]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscWellPump}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2119
|
+
@end_uses[[FT::Elec, EUT::PoolHeater]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscPoolHeater}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2120
|
+
@end_uses[[FT::Elec, EUT::PoolPump]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscPoolPump}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2121
|
+
@end_uses[[FT::Elec, EUT::HotTubHeater]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscHotTubHeater}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2122
|
+
@end_uses[[FT::Elec, EUT::HotTubPump]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscHotTubPump}:InteriorEquipment:#{EPlus::FuelTypeElectricity}"])
|
2123
|
+
end
|
2124
|
+
@end_uses[[FT::Elec, EUT::PV]] = EndUse.new(meters: ['Photovoltaic:ElectricityProduced', 'PowerConversion:ElectricityProduced'])
|
2125
|
+
@end_uses[[FT::Elec, EUT::Generator]] = EndUse.new(meters: ['Cogeneration:ElectricityProduced'])
|
2126
|
+
@end_uses[[FT::Gas, EUT::Heating]] = EndUse.new(variables: OutputVars.SpaceHeating(EPlus::FuelTypeNaturalGas))
|
2127
|
+
@end_uses[[FT::Gas, EUT::HotWater]] = EndUse.new(variables: OutputVars.WaterHeating(EPlus::FuelTypeNaturalGas))
|
2128
|
+
@end_uses[[FT::Gas, EUT::ClothesDryer]] = EndUse.new(meters: ["#{Constants.ObjectNameClothesDryer}:InteriorEquipment:#{EPlus::FuelTypeNaturalGas}"])
|
2129
|
+
@end_uses[[FT::Gas, EUT::RangeOven]] = EndUse.new(meters: ["#{Constants.ObjectNameCookingRange}:InteriorEquipment:#{EPlus::FuelTypeNaturalGas}"])
|
2130
|
+
@end_uses[[FT::Gas, EUT::MechVentPreheat]] = EndUse.new(variables: OutputVars.MechVentPreconditioning(EPlus::FuelTypeNaturalGas))
|
2016
2131
|
if @eri_design.nil? # Skip end uses not used by ERI
|
2017
|
-
@end_uses[[FT::Gas, EUT::PoolHeater]] = EndUse.new(
|
2018
|
-
@end_uses[[FT::Gas, EUT::HotTubHeater]] = EndUse.new(
|
2019
|
-
@end_uses[[FT::Gas, EUT::Grill]] = EndUse.new(
|
2020
|
-
@end_uses[[FT::Gas, EUT::Lighting]] = EndUse.new(
|
2021
|
-
@end_uses[[FT::Gas, EUT::Fireplace]] = EndUse.new(
|
2022
|
-
end
|
2023
|
-
@end_uses[[FT::
|
2024
|
-
@end_uses[[FT::Oil, EUT::
|
2025
|
-
@end_uses[[FT::Oil, EUT::
|
2026
|
-
@end_uses[[FT::Oil, EUT::
|
2027
|
-
@end_uses[[FT::Oil, EUT::
|
2132
|
+
@end_uses[[FT::Gas, EUT::PoolHeater]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscPoolHeater}:InteriorEquipment:#{EPlus::FuelTypeNaturalGas}"])
|
2133
|
+
@end_uses[[FT::Gas, EUT::HotTubHeater]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscHotTubHeater}:InteriorEquipment:#{EPlus::FuelTypeNaturalGas}"])
|
2134
|
+
@end_uses[[FT::Gas, EUT::Grill]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscGrill}:InteriorEquipment:#{EPlus::FuelTypeNaturalGas}"])
|
2135
|
+
@end_uses[[FT::Gas, EUT::Lighting]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscLighting}:InteriorEquipment:#{EPlus::FuelTypeNaturalGas}"])
|
2136
|
+
@end_uses[[FT::Gas, EUT::Fireplace]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscFireplace}:InteriorEquipment:#{EPlus::FuelTypeNaturalGas}"])
|
2137
|
+
end
|
2138
|
+
@end_uses[[FT::Gas, EUT::Generator]] = EndUse.new(meters: ["Cogeneration:#{EPlus::FuelTypeNaturalGas}"])
|
2139
|
+
@end_uses[[FT::Oil, EUT::Heating]] = EndUse.new(variables: OutputVars.SpaceHeating(EPlus::FuelTypeOil))
|
2140
|
+
@end_uses[[FT::Oil, EUT::HotWater]] = EndUse.new(variables: OutputVars.WaterHeating(EPlus::FuelTypeOil))
|
2141
|
+
@end_uses[[FT::Oil, EUT::ClothesDryer]] = EndUse.new(meters: ["#{Constants.ObjectNameClothesDryer}:InteriorEquipment:#{EPlus::FuelTypeOil}"])
|
2142
|
+
@end_uses[[FT::Oil, EUT::RangeOven]] = EndUse.new(meters: ["#{Constants.ObjectNameCookingRange}:InteriorEquipment:#{EPlus::FuelTypeOil}"])
|
2143
|
+
@end_uses[[FT::Oil, EUT::MechVentPreheat]] = EndUse.new(variables: OutputVars.MechVentPreconditioning(EPlus::FuelTypeOil))
|
2028
2144
|
if @eri_design.nil? # Skip end uses not used by ERI
|
2029
|
-
@end_uses[[FT::Oil, EUT::Grill]] = EndUse.new(
|
2030
|
-
@end_uses[[FT::Oil, EUT::Lighting]] = EndUse.new(
|
2031
|
-
@end_uses[[FT::Oil, EUT::Fireplace]] = EndUse.new(
|
2032
|
-
end
|
2033
|
-
@end_uses[[FT::
|
2034
|
-
@end_uses[[FT::Propane, EUT::
|
2035
|
-
@end_uses[[FT::Propane, EUT::
|
2036
|
-
@end_uses[[FT::Propane, EUT::
|
2037
|
-
@end_uses[[FT::Propane, EUT::
|
2145
|
+
@end_uses[[FT::Oil, EUT::Grill]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscGrill}:InteriorEquipment:#{EPlus::FuelTypeOil}"])
|
2146
|
+
@end_uses[[FT::Oil, EUT::Lighting]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscLighting}:InteriorEquipment:#{EPlus::FuelTypeOil}"])
|
2147
|
+
@end_uses[[FT::Oil, EUT::Fireplace]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscFireplace}:InteriorEquipment:#{EPlus::FuelTypeOil}"])
|
2148
|
+
end
|
2149
|
+
@end_uses[[FT::Oil, EUT::Generator]] = EndUse.new(meters: ["Cogeneration:#{EPlus::FuelTypeOil}"])
|
2150
|
+
@end_uses[[FT::Propane, EUT::Heating]] = EndUse.new(variables: OutputVars.SpaceHeating(EPlus::FuelTypePropane))
|
2151
|
+
@end_uses[[FT::Propane, EUT::HotWater]] = EndUse.new(variables: OutputVars.WaterHeating(EPlus::FuelTypePropane))
|
2152
|
+
@end_uses[[FT::Propane, EUT::ClothesDryer]] = EndUse.new(meters: ["#{Constants.ObjectNameClothesDryer}:InteriorEquipment:#{EPlus::FuelTypePropane}"])
|
2153
|
+
@end_uses[[FT::Propane, EUT::RangeOven]] = EndUse.new(meters: ["#{Constants.ObjectNameCookingRange}:InteriorEquipment:#{EPlus::FuelTypePropane}"])
|
2154
|
+
@end_uses[[FT::Propane, EUT::MechVentPreheat]] = EndUse.new(variables: OutputVars.MechVentPreconditioning(EPlus::FuelTypePropane))
|
2038
2155
|
if @eri_design.nil? # Skip end uses not used by ERI
|
2039
|
-
@end_uses[[FT::Propane, EUT::Grill]] = EndUse.new(
|
2040
|
-
@end_uses[[FT::Propane, EUT::Lighting]] = EndUse.new(
|
2041
|
-
@end_uses[[FT::Propane, EUT::Fireplace]] = EndUse.new(
|
2042
|
-
end
|
2043
|
-
@end_uses[[FT::
|
2044
|
-
@end_uses[[FT::WoodCord, EUT::
|
2045
|
-
@end_uses[[FT::WoodCord, EUT::
|
2046
|
-
@end_uses[[FT::WoodCord, EUT::
|
2047
|
-
@end_uses[[FT::WoodCord, EUT::
|
2156
|
+
@end_uses[[FT::Propane, EUT::Grill]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscGrill}:InteriorEquipment:#{EPlus::FuelTypePropane}"])
|
2157
|
+
@end_uses[[FT::Propane, EUT::Lighting]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscLighting}:InteriorEquipment:#{EPlus::FuelTypePropane}"])
|
2158
|
+
@end_uses[[FT::Propane, EUT::Fireplace]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscFireplace}:InteriorEquipment:#{EPlus::FuelTypePropane}"])
|
2159
|
+
end
|
2160
|
+
@end_uses[[FT::Propane, EUT::Generator]] = EndUse.new(meters: ["Cogeneration:#{EPlus::FuelTypePropane}"])
|
2161
|
+
@end_uses[[FT::WoodCord, EUT::Heating]] = EndUse.new(variables: OutputVars.SpaceHeating(EPlus::FuelTypeWoodCord))
|
2162
|
+
@end_uses[[FT::WoodCord, EUT::HotWater]] = EndUse.new(variables: OutputVars.WaterHeating(EPlus::FuelTypeWoodCord))
|
2163
|
+
@end_uses[[FT::WoodCord, EUT::ClothesDryer]] = EndUse.new(meters: ["#{Constants.ObjectNameClothesDryer}:InteriorEquipment:#{EPlus::FuelTypeWoodCord}"])
|
2164
|
+
@end_uses[[FT::WoodCord, EUT::RangeOven]] = EndUse.new(meters: ["#{Constants.ObjectNameCookingRange}:InteriorEquipment:#{EPlus::FuelTypeWoodCord}"])
|
2165
|
+
@end_uses[[FT::WoodCord, EUT::MechVentPreheat]] = EndUse.new(variables: OutputVars.MechVentPreconditioning(EPlus::FuelTypeWoodCord))
|
2048
2166
|
if @eri_design.nil? # Skip end uses not used by ERI
|
2049
|
-
@end_uses[[FT::WoodCord, EUT::Grill]] = EndUse.new(
|
2050
|
-
@end_uses[[FT::WoodCord, EUT::Lighting]] = EndUse.new(
|
2051
|
-
@end_uses[[FT::WoodCord, EUT::Fireplace]] = EndUse.new(
|
2052
|
-
end
|
2053
|
-
@end_uses[[FT::
|
2054
|
-
@end_uses[[FT::WoodPellets, EUT::
|
2055
|
-
@end_uses[[FT::WoodPellets, EUT::
|
2056
|
-
@end_uses[[FT::WoodPellets, EUT::
|
2057
|
-
@end_uses[[FT::WoodPellets, EUT::
|
2167
|
+
@end_uses[[FT::WoodCord, EUT::Grill]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscGrill}:InteriorEquipment:#{EPlus::FuelTypeWoodCord}"])
|
2168
|
+
@end_uses[[FT::WoodCord, EUT::Lighting]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscLighting}:InteriorEquipment:#{EPlus::FuelTypeWoodCord}"])
|
2169
|
+
@end_uses[[FT::WoodCord, EUT::Fireplace]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscFireplace}:InteriorEquipment:#{EPlus::FuelTypeWoodCord}"])
|
2170
|
+
end
|
2171
|
+
@end_uses[[FT::WoodCord, EUT::Generator]] = EndUse.new(meters: ["Cogeneration:#{EPlus::FuelTypeWoodCord}"])
|
2172
|
+
@end_uses[[FT::WoodPellets, EUT::Heating]] = EndUse.new(variables: OutputVars.SpaceHeating(EPlus::FuelTypeWoodPellets))
|
2173
|
+
@end_uses[[FT::WoodPellets, EUT::HotWater]] = EndUse.new(variables: OutputVars.WaterHeating(EPlus::FuelTypeWoodPellets))
|
2174
|
+
@end_uses[[FT::WoodPellets, EUT::ClothesDryer]] = EndUse.new(meters: ["#{Constants.ObjectNameClothesDryer}:InteriorEquipment:#{EPlus::FuelTypeWoodPellets}"])
|
2175
|
+
@end_uses[[FT::WoodPellets, EUT::RangeOven]] = EndUse.new(meters: ["#{Constants.ObjectNameCookingRange}:InteriorEquipment:#{EPlus::FuelTypeWoodPellets}"])
|
2176
|
+
@end_uses[[FT::WoodPellets, EUT::MechVentPreheat]] = EndUse.new(variables: OutputVars.MechVentPreconditioning(EPlus::FuelTypeWoodPellets))
|
2058
2177
|
if @eri_design.nil? # Skip end uses not used by ERI
|
2059
|
-
@end_uses[[FT::WoodPellets, EUT::Grill]] = EndUse.new(
|
2060
|
-
@end_uses[[FT::WoodPellets, EUT::Lighting]] = EndUse.new(
|
2061
|
-
@end_uses[[FT::WoodPellets, EUT::Fireplace]] = EndUse.new(
|
2062
|
-
end
|
2063
|
-
@end_uses[[FT::
|
2064
|
-
@end_uses[[FT::Coal, EUT::
|
2065
|
-
@end_uses[[FT::Coal, EUT::
|
2066
|
-
@end_uses[[FT::Coal, EUT::
|
2067
|
-
@end_uses[[FT::Coal, EUT::
|
2178
|
+
@end_uses[[FT::WoodPellets, EUT::Grill]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscGrill}:InteriorEquipment:#{EPlus::FuelTypeWoodPellets}"])
|
2179
|
+
@end_uses[[FT::WoodPellets, EUT::Lighting]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscLighting}:InteriorEquipment:#{EPlus::FuelTypeWoodPellets}"])
|
2180
|
+
@end_uses[[FT::WoodPellets, EUT::Fireplace]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscFireplace}:InteriorEquipment:#{EPlus::FuelTypeWoodPellets}"])
|
2181
|
+
end
|
2182
|
+
@end_uses[[FT::WoodPellets, EUT::Generator]] = EndUse.new(meters: ["Cogeneration:#{EPlus::FuelTypeWoodPellets}"])
|
2183
|
+
@end_uses[[FT::Coal, EUT::Heating]] = EndUse.new(variables: OutputVars.SpaceHeating(EPlus::FuelTypeCoal))
|
2184
|
+
@end_uses[[FT::Coal, EUT::HotWater]] = EndUse.new(variables: OutputVars.WaterHeating(EPlus::FuelTypeCoal))
|
2185
|
+
@end_uses[[FT::Coal, EUT::ClothesDryer]] = EndUse.new(meters: ["#{Constants.ObjectNameClothesDryer}:InteriorEquipment:#{EPlus::FuelTypeCoal}"])
|
2186
|
+
@end_uses[[FT::Coal, EUT::RangeOven]] = EndUse.new(meters: ["#{Constants.ObjectNameCookingRange}:InteriorEquipment:#{EPlus::FuelTypeCoal}"])
|
2187
|
+
@end_uses[[FT::Coal, EUT::MechVentPreheat]] = EndUse.new(variables: OutputVars.MechVentPreconditioning(EPlus::FuelTypeCoal))
|
2068
2188
|
if @eri_design.nil? # Skip end uses not used by ERI
|
2069
|
-
@end_uses[[FT::Coal, EUT::Grill]] = EndUse.new(
|
2070
|
-
@end_uses[[FT::Coal, EUT::Lighting]] = EndUse.new(
|
2071
|
-
@end_uses[[FT::Coal, EUT::Fireplace]] = EndUse.new(
|
2189
|
+
@end_uses[[FT::Coal, EUT::Grill]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscGrill}:InteriorEquipment:#{EPlus::FuelTypeCoal}"])
|
2190
|
+
@end_uses[[FT::Coal, EUT::Lighting]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscLighting}:InteriorEquipment:#{EPlus::FuelTypeCoal}"])
|
2191
|
+
@end_uses[[FT::Coal, EUT::Fireplace]] = EndUse.new(meters: ["#{Constants.ObjectNameMiscFireplace}:InteriorEquipment:#{EPlus::FuelTypeCoal}"])
|
2072
2192
|
end
|
2193
|
+
@end_uses[[FT::Coal, EUT::Generator]] = EndUse.new(meters: ["Cogeneration:#{EPlus::FuelTypeCoal}"])
|
2073
2194
|
|
2074
2195
|
@end_uses.each do |key, end_use|
|
2075
2196
|
fuel_type, end_use_type = key
|
2076
|
-
end_use.name = "#{fuel_type}: #{end_use_type}"
|
2197
|
+
end_use.name = "End Use: #{fuel_type}: #{end_use_type}"
|
2077
2198
|
end_use.annual_units = 'MBtu'
|
2078
2199
|
end_use.timeseries_units = get_timeseries_units_from_fuel_type(fuel_type)
|
2079
2200
|
end
|
@@ -2094,8 +2215,8 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
2094
2215
|
|
2095
2216
|
# Peak Fuels
|
2096
2217
|
@peak_fuels = {}
|
2097
|
-
@peak_fuels[[FT::Elec, PFT::Winter]] = PeakFuel.new(
|
2098
|
-
@peak_fuels[[FT::Elec, PFT::Summer]] = PeakFuel.new(
|
2218
|
+
@peak_fuels[[FT::Elec, PFT::Winter]] = PeakFuel.new(meters: ['Heating:EnergyTransfer'], report: 'Peak Electricity Winter Total')
|
2219
|
+
@peak_fuels[[FT::Elec, PFT::Summer]] = PeakFuel.new(meters: ['Cooling:EnergyTransfer'], report: 'Peak Electricity Summer Total')
|
2099
2220
|
|
2100
2221
|
@peak_fuels.each do |key, peak_fuel|
|
2101
2222
|
fuel_type, peak_fuel_type = key
|
@@ -2108,9 +2229,9 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
2108
2229
|
@loads = {}
|
2109
2230
|
@loads[LT::Heating] = Load.new(ems_variable: 'loads_htg_tot')
|
2110
2231
|
@loads[LT::Cooling] = Load.new(ems_variable: 'loads_clg_tot')
|
2111
|
-
@loads[LT::HotWaterDelivered] = Load.new(
|
2232
|
+
@loads[LT::HotWaterDelivered] = Load.new(variables: OutputVars.WaterHeatingLoad)
|
2112
2233
|
@loads[LT::HotWaterTankLosses] = Load.new()
|
2113
|
-
@loads[LT::HotWaterDesuperheater] = Load.new(
|
2234
|
+
@loads[LT::HotWaterDesuperheater] = Load.new(variables: OutputVars.WaterHeaterLoadDesuperheater)
|
2114
2235
|
@loads[LT::HotWaterSolarThermal] = Load.new()
|
2115
2236
|
|
2116
2237
|
@loads.each do |load_type, load|
|
@@ -2137,7 +2258,6 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
2137
2258
|
@component_loads[[LT::Heating, CLT::NaturalVentilation]] = ComponentLoad.new(ems_variable: 'loads_htg_natvent')
|
2138
2259
|
@component_loads[[LT::Heating, CLT::MechanicalVentilation]] = ComponentLoad.new(ems_variable: 'loads_htg_mechvent')
|
2139
2260
|
@component_loads[[LT::Heating, CLT::WholeHouseFan]] = ComponentLoad.new(ems_variable: 'loads_htg_whf')
|
2140
|
-
@component_loads[[LT::Heating, CLT::ClothesDryerExhaust]] = ComponentLoad.new(ems_variable: 'loads_htg_cd')
|
2141
2261
|
@component_loads[[LT::Heating, CLT::Ducts]] = ComponentLoad.new(ems_variable: 'loads_htg_ducts')
|
2142
2262
|
@component_loads[[LT::Heating, CLT::InternalGains]] = ComponentLoad.new(ems_variable: 'loads_htg_intgains')
|
2143
2263
|
@component_loads[[LT::Cooling, CLT::Roofs]] = ComponentLoad.new(ems_variable: 'loads_clg_roofs')
|
@@ -2155,7 +2275,6 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
2155
2275
|
@component_loads[[LT::Cooling, CLT::NaturalVentilation]] = ComponentLoad.new(ems_variable: 'loads_clg_natvent')
|
2156
2276
|
@component_loads[[LT::Cooling, CLT::MechanicalVentilation]] = ComponentLoad.new(ems_variable: 'loads_clg_mechvent')
|
2157
2277
|
@component_loads[[LT::Cooling, CLT::WholeHouseFan]] = ComponentLoad.new(ems_variable: 'loads_clg_whf')
|
2158
|
-
@component_loads[[LT::Cooling, CLT::ClothesDryerExhaust]] = ComponentLoad.new(ems_variable: 'loads_clg_cd')
|
2159
2278
|
@component_loads[[LT::Cooling, CLT::Ducts]] = ComponentLoad.new(ems_variable: 'loads_clg_ducts')
|
2160
2279
|
@component_loads[[LT::Cooling, CLT::InternalGains]] = ComponentLoad.new(ems_variable: 'loads_clg_intgains')
|
2161
2280
|
|
@@ -2174,6 +2293,7 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
2174
2293
|
@unmet_loads.each do |load_type, unmet_load|
|
2175
2294
|
unmet_load.name = "Unmet Load: #{load_type}"
|
2176
2295
|
unmet_load.annual_units = 'MBtu'
|
2296
|
+
unmet_load.timeseries_units = 'kBtu'
|
2177
2297
|
end
|
2178
2298
|
|
2179
2299
|
# Ideal System Loads (expected load that is not met by HVAC)
|
@@ -2188,8 +2308,8 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
2188
2308
|
|
2189
2309
|
# Peak Loads
|
2190
2310
|
@peak_loads = {}
|
2191
|
-
@peak_loads[LT::Heating] = PeakLoad.new(
|
2192
|
-
@peak_loads[LT::Cooling] = PeakLoad.new(
|
2311
|
+
@peak_loads[LT::Heating] = PeakLoad.new(meters: ['Heating:EnergyTransfer'])
|
2312
|
+
@peak_loads[LT::Cooling] = PeakLoad.new(meters: ['Cooling:EnergyTransfer'])
|
2193
2313
|
|
2194
2314
|
@peak_loads.each do |load_type, peak_load|
|
2195
2315
|
peak_load.name = "Peak Load: #{load_type}"
|
@@ -2203,10 +2323,9 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
2203
2323
|
# Airflows
|
2204
2324
|
@airflows = {}
|
2205
2325
|
@airflows[AFT::Infiltration] = Airflow.new(ems_program: Constants.ObjectNameInfiltration + ' program', ems_variables: [(Constants.ObjectNameInfiltration + ' flow act').gsub(' ', '_')])
|
2206
|
-
@airflows[AFT::MechanicalVentilation] = Airflow.new(ems_program: Constants.ObjectNameInfiltration + ' program', ems_variables: [
|
2326
|
+
@airflows[AFT::MechanicalVentilation] = Airflow.new(ems_program: Constants.ObjectNameInfiltration + ' program', ems_variables: ['Qfan'])
|
2207
2327
|
@airflows[AFT::NaturalVentilation] = Airflow.new(ems_program: Constants.ObjectNameNaturalVentilation + ' program', ems_variables: [(Constants.ObjectNameNaturalVentilation + ' flow act').gsub(' ', '_')])
|
2208
2328
|
@airflows[AFT::WholeHouseFan] = Airflow.new(ems_program: Constants.ObjectNameNaturalVentilation + ' program', ems_variables: [(Constants.ObjectNameWholeHouseFan + ' flow act').gsub(' ', '_')])
|
2209
|
-
@airflows[AFT::ClothesDryerExhaust] = Airflow.new(ems_program: Constants.ObjectNameInfiltration + ' program', ems_variables: [(Constants.ObjectNameClothesDryerExhaust + ' flow act').gsub(' ', '_')])
|
2210
2329
|
|
2211
2330
|
@airflows.each do |airflow_type, airflow|
|
2212
2331
|
airflow.name = "Airflow: #{airflow_type}"
|
@@ -2237,19 +2356,13 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
2237
2356
|
end
|
2238
2357
|
|
2239
2358
|
class OutputVars
|
2240
|
-
def self.
|
2241
|
-
return { 'OpenStudio::Model::AirLoopHVACUnitarySystem' => [
|
2242
|
-
'OpenStudio::Model::CoilHeatingDXSingleSpeed' => [
|
2243
|
-
'OpenStudio::Model::CoilHeatingDXMultiSpeed' => [
|
2244
|
-
'OpenStudio::Model::CoilHeatingElectric' => [
|
2245
|
-
'OpenStudio::Model::
|
2246
|
-
'OpenStudio::Model::
|
2247
|
-
'OpenStudio::Model::BoilerHotWater' => ['Boiler Electric Energy'] }
|
2248
|
-
end
|
2249
|
-
|
2250
|
-
def self.SpaceHeatingFuel(fuel)
|
2251
|
-
fuel = EPlus.output_fuel_map(fuel)
|
2252
|
-
return { 'OpenStudio::Model::CoilHeatingGas' => ["Heating Coil #{fuel} Energy"],
|
2359
|
+
def self.SpaceHeating(fuel)
|
2360
|
+
return { 'OpenStudio::Model::AirLoopHVACUnitarySystem' => ["Unitary System Heating Ancillary #{fuel} Energy"],
|
2361
|
+
'OpenStudio::Model::CoilHeatingDXSingleSpeed' => ["Heating Coil #{fuel} Energy", "Heating Coil Crankcase Heater #{fuel} Energy", "Heating Coil Defrost #{fuel} Energy"],
|
2362
|
+
'OpenStudio::Model::CoilHeatingDXMultiSpeed' => ["Heating Coil #{fuel} Energy", "Heating Coil Crankcase Heater #{fuel} Energy", "Heating Coil Defrost #{fuel} Energy"],
|
2363
|
+
'OpenStudio::Model::CoilHeatingElectric' => ["Heating Coil #{fuel} Energy", "Heating Coil Crankcase Heater #{fuel} Energy", "Heating Coil Defrost #{fuel} Energy"],
|
2364
|
+
'OpenStudio::Model::CoilHeatingGas' => ["Heating Coil #{fuel} Energy"],
|
2365
|
+
'OpenStudio::Model::CoilHeatingWaterToAirHeatPumpEquationFit' => ["Heating Coil #{fuel} Energy", "Heating Coil Crankcase Heater #{fuel} Energy", "Heating Coil Defrost #{fuel} Energy"],
|
2253
2366
|
'OpenStudio::Model::ZoneHVACBaseboardConvectiveElectric' => ["Baseboard #{fuel} Energy"],
|
2254
2367
|
'OpenStudio::Model::BoilerHotWater' => ["Boiler #{fuel} Energy"] }
|
2255
2368
|
end
|
@@ -2265,34 +2378,33 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
2265
2378
|
end
|
2266
2379
|
|
2267
2380
|
def self.SpaceCoolingElectricity
|
2268
|
-
|
2269
|
-
|
2270
|
-
'OpenStudio::Model::
|
2271
|
-
'OpenStudio::Model::
|
2381
|
+
fuel = EPlus::FuelTypeElectricity
|
2382
|
+
return { 'OpenStudio::Model::CoilCoolingDXSingleSpeed' => ["Cooling Coil #{fuel} Energy", "Cooling Coil Crankcase Heater #{fuel} Energy"],
|
2383
|
+
'OpenStudio::Model::CoilCoolingDXMultiSpeed' => ["Cooling Coil #{fuel} Energy", "Cooling Coil Crankcase Heater #{fuel} Energy"],
|
2384
|
+
'OpenStudio::Model::CoilCoolingWaterToAirHeatPumpEquationFit' => ["Cooling Coil #{fuel} Energy", "Cooling Coil Crankcase Heater #{fuel} Energy"],
|
2385
|
+
'OpenStudio::Model::EvaporativeCoolerDirectResearchSpecial' => ["Evaporative Cooler #{fuel} Energy"] }
|
2272
2386
|
end
|
2273
2387
|
|
2274
2388
|
def self.DehumidifierElectricity
|
2275
|
-
|
2276
|
-
|
2277
|
-
|
2278
|
-
def self.WaterHeatingElectricity
|
2279
|
-
return { 'OpenStudio::Model::WaterHeaterMixed' => ['Water Heater Electric Energy', 'Water Heater Off Cycle Parasitic Electric Energy', 'Water Heater On Cycle Parasitic Electric Energy'],
|
2280
|
-
'OpenStudio::Model::WaterHeaterStratified' => ['Water Heater Electric Energy', 'Water Heater Off Cycle Parasitic Electric Energy', 'Water Heater On Cycle Parasitic Electric Energy'],
|
2281
|
-
'OpenStudio::Model::CoilWaterHeatingAirToWaterHeatPumpWrapped' => ['Cooling Coil Water Heating Electric Energy'] }
|
2389
|
+
fuel = EPlus::FuelTypeElectricity
|
2390
|
+
return { 'OpenStudio::Model::ZoneHVACDehumidifierDX' => ["Zone Dehumidifier #{fuel} Energy"] }
|
2282
2391
|
end
|
2283
2392
|
|
2284
2393
|
def self.WaterHeatingElectricitySolarThermalPump
|
2285
|
-
|
2394
|
+
fuel = EPlus::FuelTypeElectricity
|
2395
|
+
return { 'OpenStudio::Model::PumpConstantSpeed' => ["Pump #{fuel} Energy"] }
|
2286
2396
|
end
|
2287
2397
|
|
2288
2398
|
def self.WaterHeatingElectricityRecircPump
|
2289
|
-
|
2399
|
+
fuel = EPlus::FuelTypeElectricity
|
2400
|
+
return { 'OpenStudio::Model::ElectricEquipment' => ["Electric Equipment #{fuel} Energy"] }
|
2290
2401
|
end
|
2291
2402
|
|
2292
|
-
def self.
|
2293
|
-
fuel
|
2294
|
-
|
2295
|
-
'OpenStudio::Model::
|
2403
|
+
def self.WaterHeating(fuel)
|
2404
|
+
return { 'OpenStudio::Model::WaterHeaterMixed' => ["Water Heater #{fuel} Energy", "Water Heater Off Cycle Parasitic #{fuel} Energy", "Water Heater On Cycle Parasitic #{fuel} Energy"],
|
2405
|
+
'OpenStudio::Model::WaterHeaterStratified' => ["Water Heater #{fuel} Energy", "Water Heater Off Cycle Parasitic #{fuel} Energy", "Water Heater On Cycle Parasitic #{fuel} Energy"],
|
2406
|
+
'OpenStudio::Model::CoilWaterHeatingAirToWaterHeatPumpWrapped' => ["Cooling Coil Water Heating #{fuel} Energy"],
|
2407
|
+
'OpenStudio::Model::FanOnOff' => ["Fan #{fuel} Energy"] }
|
2296
2408
|
end
|
2297
2409
|
|
2298
2410
|
def self.WaterHeatingLoad
|
@@ -2312,15 +2424,20 @@ class SimulationOutputReport < OpenStudio::Measure::ReportingMeasure
|
|
2312
2424
|
return { 'OpenStudio::Model::WaterHeaterStratified' => ['Water Heater Use Side Heat Transfer Energy'] }
|
2313
2425
|
end
|
2314
2426
|
|
2315
|
-
def self.
|
2316
|
-
return { 'OpenStudio::Model::OtherEquipment' => [
|
2427
|
+
def self.MechVentPreconditioning(fuel)
|
2428
|
+
return { 'OpenStudio::Model::OtherEquipment' => ["Other Equipment #{fuel} Energy"] }
|
2317
2429
|
end
|
2430
|
+
end
|
2431
|
+
end
|
2318
2432
|
|
2319
|
-
|
2320
|
-
|
2321
|
-
|
2433
|
+
def get_all_variable_keys(vars)
|
2434
|
+
var_keys = []
|
2435
|
+
vars.keys.each do |key|
|
2436
|
+
vars[key].each do |var_key|
|
2437
|
+
var_keys << var_key
|
2322
2438
|
end
|
2323
2439
|
end
|
2440
|
+
return var_keys
|
2324
2441
|
end
|
2325
2442
|
|
2326
2443
|
# register the measure to be used by the application
|