urbanopt-cli 0.4.1 → 0.6.1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/.gitignore +3 -1
- data/CHANGELOG.md +59 -0
- data/CMakeLists.txt +17 -17
- data/FindOpenStudioSDK.cmake +12 -7
- data/Gemfile +8 -10
- data/LICENSE.md +11 -1
- data/README.md +1 -0
- data/Rakefile +16 -6
- data/example_files/Gemfile +25 -9
- data/example_files/example_project.json +35 -20
- data/example_files/example_project_combined.json +100 -5
- data/example_files/example_project_with_electric_network.json +2116 -0
- data/example_files/mappers/Baseline.rb +111 -51
- data/example_files/mappers/CreateBar.rb +19 -7
- data/example_files/mappers/EvCharging.rb +141 -0
- data/example_files/mappers/Floorspace.rb +29 -17
- data/example_files/mappers/HighEfficiency.rb +20 -8
- data/example_files/mappers/HighEfficiencyCreateBar.rb +19 -8
- data/example_files/mappers/HighEfficiencyFloorspace.rb +19 -8
- data/example_files/mappers/ThermalStorage.rb +16 -6
- data/example_files/mappers/base_workflow.osw +26 -1
- data/example_files/mappers/floorspace_workflow.osw +9 -0
- data/example_files/measures/BuildResidentialModel/measure.rb +249 -134
- data/example_files/reopt/base_assumptions.json +2 -2
- data/example_files/reopt/multiPV_assumptions.json +4 -3
- data/example_files/residential/clothes_dryer.tsv +7 -7
- data/example_files/residential/clothes_washer.tsv +2 -2
- data/example_files/residential/cooling_system.tsv +42 -22
- data/example_files/residential/dishwasher.tsv +1 -1
- data/example_files/residential/exhaust.tsv +3 -0
- data/example_files/residential/heat_pump.tsv +62 -40
- data/example_files/residential/water_heater.tsv +1 -1
- data/example_files/resources/hpxml-measures/.github/pull_request_template.md +14 -0
- data/example_files/resources/hpxml-measures/.github/workflows/config.yml +116 -0
- data/example_files/resources/hpxml-measures/.gitignore +1 -8
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.rb +1088 -1329
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.xml +1819 -1383
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/constants.rb +0 -8
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/geometry.rb +450 -362
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules.rb +165 -112
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_config.json +388 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_config.md +43 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_weekday_state_and_monthly_schedule_shift.csv +613 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_weekend_state_and_monthly_schedule_shift.csv +613 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-coal.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-appliances-dehumidifier-ief.osw → base-appliances-dehumidifier-ief-portable.osw} +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-appliances-dehumidifier-50percent.osw → base-appliances-dehumidifier-ief-whole-home.osw} +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-dehumidifier.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-modified.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-none.osw +61 -87
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-oil.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-propane.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-wood.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-flat.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-radiant-barrier.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-unvented-insulated-roof.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-vented.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-boiler-only-baseboard.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-boiler-only-fan-coil.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-mechvent-shared-preconditioning.osw → base-bldgtype-multifamily-shared-mechvent-preconditioning.osw} +70 -95
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-mechvent-shared.osw → base-bldgtype-multifamily-shared-mechvent.osw} +70 -95
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-pv.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-water-heater.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-single-family-attached.osw → base-bldgtype-single-family-attached.osw} +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-combi-tankless-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-combi-tankless.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-dwhr.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-standbyloss.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-with-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-electric.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-hpwh.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-indirect.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-low-flow-fixtures.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-none.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-demand.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-manual.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-nocontrol.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-temperature.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-timer.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-evacuated-tube.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-flat-plate.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-ics.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-indirect-flat-plate.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-thermosyphon-flat-plate.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-coal.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-elec-uef.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas-uef.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-uef.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-with-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-with-solar.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-oil.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-wood.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric-outside.osw +56 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric-uef.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-uef.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-with-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-with-solar.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-propane.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-2stories-garage.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-2stories.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-1.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-2.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-4.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-5.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-garage.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-ach-house-pressure.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-cfm-house-pressure.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-cfm50.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-flue.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-natural-ach.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-overhangs.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-windows-none.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-ambient.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-conditioned-basement-slab-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-slab.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement-assembly-r.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement-wall-insulation.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unvented-crawlspace.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-vented-crawlspace.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed-cooling-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed-heating-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-2-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-var-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-coal-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-elec-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-gas-central-ac-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-gas-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-oil-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-propane-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-wood-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-2-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-var-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-plus-air-to-air-heat-pump-heating.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-electric.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-2-speed.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-var-speed.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-mini-split-heat-pump-ducted.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ducts-leakage-percent.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-elec-resistance-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-furnace-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-only-ducted.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-fireplace-wood-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-fixed-heater-gas-only.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-floor-furnace-propane-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-coal-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-elec-central-ac-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-elec-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-central-ac-2-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-central-ac-var-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-room-ac.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-oil-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-propane-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-wood-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump-cooling-only.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump-heating-only.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump.osw +56 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-airflow-defect-furnace-gas-central-ac-1-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-1-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-2-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-var-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-1-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-2-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-var-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-only.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-ground-to-air-heat-pump.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-mini-split-air-conditioner-only-ducted.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-mini-split-heat-pump-ducted.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-charge-defect-furnace-gas-central-ac-1-speed.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-none-furnace-gas-central-ac-1-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-air-conditioner-only-ducted.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-air-conditioner-only-ductless.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted-cooling-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted-heating-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ductless.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-none.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-portable-heater-gas-only.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-programmable-thermostat-detailed.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-room-ac-only-33percent.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-room-ac-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-setpoints.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-stove-oil-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-stove-wood-pellets-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-undersized.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-wall-furnace-elec-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-lighting-ceiling-fans.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-lighting-detailed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-AMY-2012.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-baltimore-md.osw +64 -90
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-dallas-tx.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-duluth-mn.osw +69 -95
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-helena-mt.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-honolulu-hi.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-miami-fl.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-phoenix-az.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-portland-or.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-balanced.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-bath-kitchen-fans.osw +64 -92
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-cfis-evap-cooler-only-ducted.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-cfis.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-erv-atre-asre.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-erv.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-exhaust-rated-flow-rate.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-exhaust.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-hrv-asre.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-hrv.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-supply.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-whole-house-fan.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-defaults.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-loads-large-uncommon.osw +60 -86
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-loads-large-uncommon2.osw +60 -86
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-neighbor-shading.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-shielding-of-home.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-usage-multiplier.osw +52 -78
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-pv.osw +52 -78
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-vacancy-6-months.osw → base-schedules-stochastic-vacant.osw} +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-schedules-stochastic.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-schedules-user-specified.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-calendar-year-custom.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-daylight-saving-custom.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-daylight-saving-disabled.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-runperiod-1-month.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-timestep-10-mins.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/build_residential_hpxml_test.rb +71 -57
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-auto.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-double-exterior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-eaves.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-single-exterior-front.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-atticroof-conditioned-eaves-gable.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-atticroof-conditioned-eaves-hip.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-atticroof-flat.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-pv-shared.osw → extra-bldgtype-single-family-attached-double-exterior.osw} +62 -89
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-double-loaded-interior.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-dhw-shared-water-heater.osw → extra-bldgtype-single-family-attached-single-exterior-front.osw} +60 -86
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unconditioned-basement-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unconditioned-basement-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-multifamily.osw → extra-bldgtype-single-family-attached-unconditioned-basement.osw} +64 -91
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-dhw-solar-latitude.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-atticroof-conditioned-eaves-gable.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-atticroof-conditioned-eaves-hip.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-garage-atticroof-conditioned.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-garage-partially-protruded.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-windows-shading.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-gas-hot-tub-heater-with-zero-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-gas-pool-heater-with-zero-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-pv-roofpitch.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-schedules-random-seed.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-boiler-to-heat-pump.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-boiler-to-heating-system.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-fireplace-to-heat-pump.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-second-heating-system-fireplace.osw → extra-second-heating-system-fireplace-to-heating-system.osw} +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-portable-heater-to-heat-pump.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-second-heating-system-portable-heater.osw → extra-second-heating-system-portable-heater-to-heating-system.osw} +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-refrigerator.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-clothes-washer-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-dishwasher-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-extra-refrigerator-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-freezer-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-refrigerator-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-attic-with-floor-insulation.osw +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-attic-with-one-floor-above-grade.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-basement-with-ceiling-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/cooling-system-and-heat-pump.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/dhw-indirect-without-boiler.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/ducts-location-and-areas-not-same-type.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/foundation-wall-insulation-greater-than-height.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/heating-system-and-heat-pump.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-bottom-crawlspace-zero-foundation-height.osw +64 -89
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-bottom-slab-non-zero-foundation-height.osw +64 -89
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-no-building-orientation.osw +63 -88
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-hvac-programmable-thermostat.osw → invalid_files/multipliers-without-fuel-loads.osw} +54 -80
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-other-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-tv-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-dhw-uef.osw → invalid_files/multipliers-without-vehicle-plug-loads.osw} +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-well-pump-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-electric-heat-pump-water-heater.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-integer-ceiling-fan-quantity.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-integer-geometry-num-bathrooms.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-but-no-primary-heating.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-serves-majority-heat.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-serves-total-heat-load.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-attached-ambient.osw +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-attached-no-building-orientation.osw +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-detached-finished-basement-zero-foundation-height.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-detached-slab-non-zero-foundation-height.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-detached-with-shared-system.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/slab-non-zero-foundation-height-above-grade.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unconditioned-basement-with-wall-and-ceiling-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unvented-attic-with-floor-and-roof-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unvented-crawlspace-with-wall-and-ceiling-insulation.osw +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/vented-attic-with-floor-and-roof-insulation.osw +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/vented-crawlspace-with-wall-and-ceiling-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/zero-number-of-bedrooms.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/schedules/vacant.csv +8761 -0
- data/example_files/resources/hpxml-measures/Changelog.md +249 -0
- data/example_files/resources/hpxml-measures/Gemfile +2 -5
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.rb +404 -1357
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.xml +247 -171
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/BaseElements.xsd +11 -101
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/EPvalidator.xml +824 -301
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/HPXMLDataTypes.xsd +18 -35
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/HPXMLvalidator.xml +526 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/airflow.rb +135 -207
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constants.rb +14 -186
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constructions.rb +549 -93
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/energyplus.rb +12 -15
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/generator.rb +78 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/geometry.rb +413 -15
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hotwater_appliances.rb +48 -37
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml.rb +1627 -1227
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_defaults.rb +1192 -434
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac.rb +1555 -1616
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac_sizing.rb +1436 -1479
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/lighting.rb +3 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/location.rb +22 -10
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/meta_measure.rb +85 -19
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/minitest_helper.rb +4 -26
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/misc_loads.rb +22 -46
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/pv.rb +22 -21
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedules.rb +51 -14
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/simcontrols.rb +24 -7
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/unit_conversions.rb +2 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/validator.rb +80 -19
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/version.rb +9 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/waterheater.rb +106 -75
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/xmlhelper.rb +109 -34
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_airflow.rb +22 -36
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_defaults.rb +1565 -768
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_enclosure.rb +151 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_generator.rb +101 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb +9 -18
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac.rb +316 -28
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac_sizing.rb +53 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_lighting.rb +4 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_location.rb +13 -11
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_miscloads.rb +4 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_pv.rb +5 -3
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_simcontrols.rb +13 -11
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_validation.rb +102 -62
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_water_heater.rb +189 -35
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/util.rb +26 -0
- data/example_files/resources/hpxml-measures/README.md +5 -5
- data/example_files/resources/hpxml-measures/Rakefile +2 -10
- data/example_files/resources/hpxml-measures/SimulationOutputReport/measure.rb +416 -299
- data/example_files/resources/hpxml-measures/SimulationOutputReport/measure.xml +364 -481
- data/example_files/resources/hpxml-measures/SimulationOutputReport/resources/constants.rb +1 -2
- data/example_files/resources/hpxml-measures/SimulationOutputReport/tests/output_report_test.rb +327 -320
- data/example_files/resources/hpxml-measures/docs/source/build_residential_hpxml.rst +3 -3
- data/example_files/resources/hpxml-measures/docs/source/conf.py +11 -5
- data/example_files/resources/hpxml-measures/docs/source/getting_started.rst +6 -6
- data/example_files/resources/hpxml-measures/docs/source/index.rst +2 -2
- data/example_files/resources/hpxml-measures/docs/source/intro.rst +7 -109
- data/example_files/resources/hpxml-measures/docs/source/nstatic/stylesheet.css +13 -1
- data/example_files/resources/hpxml-measures/docs/source/workflow_inputs.rst +2482 -0
- data/example_files/resources/hpxml-measures/docs/source/workflow_outputs.rst +282 -0
- data/example_files/resources/hpxml-measures/tasks.rb +2494 -1248
- data/example_files/resources/hpxml-measures/weather/USA_AZ_Phoenix-Sky.Harbor.Intl.AP.722780_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_AZ_Phoenix-Sky.Harbor.Intl.AP.722780_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_CO_Denver.Intl.AP.725650_TMY3-cache.csv +10 -10
- data/example_files/resources/hpxml-measures/weather/USA_HI_Honolulu.Intl.AP.911820_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_HI_Honolulu.Intl.AP.911820_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_MT_Helena.Rgnl.AP.727720_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_MT_Helena.Rgnl.AP.727720_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_OR_Portland.Intl.AP.726980_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_OR_Portland.Intl.AP.726980_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/workflow/run_simulation.rb +96 -21
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-coal.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-appliances-dehumidifier-ief.xml → base-appliances-dehumidifier-ief-portable.xml} +8 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-appliances-dehumidifier-50percent.xml → base-appliances-dehumidifier-ief-whole-home.xml} +10 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-multiple.xml +535 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier.xml +525 -524
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-gas.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-modified.xml +564 -565
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-none.xml +513 -513
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-oil.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-propane.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-wood.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-cathedral.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-conditioned.xml +633 -634
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-flat.xml +531 -532
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-radiant-barrier.xml +517 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-unvented-insulated-roof.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-vented.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-multifamily-buffer-space.xml → base-bldgtype-multifamily-adjacent-to-multifamily-buffer-space.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-multiple.xml +554 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-non-freezing-space.xml → base-bldgtype-multifamily-adjacent-to-non-freezing-space.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-heated-space.xml → base-bldgtype-multifamily-adjacent-to-other-heated-space.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-housing-unit.xml → base-bldgtype-multifamily-adjacent-to-other-housing-unit.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-baseboard.xml +425 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-fan-coil-ducted.xml +457 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-fan-coil.xml +427 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-water-loop-heat-pump.xml +479 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-cooling-tower-water-loop-heat-pump.xml +474 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-baseboard.xml +408 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil-ducted.xml +439 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil-eae.xml +406 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil.xml +409 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-water-loop-heat-pump.xml +457 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-baseboard.xml +407 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-fan-coil-ducted.xml +438 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-fan-coil.xml +408 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-water-loop-heat-pump.xml +456 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-cooling-tower-only-water-loop-heat-pump.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-generator.xml +460 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-ground-loop-ground-to-air-heat-pump.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-laundry-room.xml +466 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-mechvent-shared-multiple.xml → base-bldgtype-multifamily-shared-mechvent-multiple.xml} +43 -415
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent-preconditioning.xml +489 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent.xml +473 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-pv.xml +465 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-water-heater-recirc.xml +458 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-water-heater.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily.xml +448 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-single-family-attached.xml +619 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless-outside.xml +516 -519
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless.xml +516 -519
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-2-speed.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-gshp.xml +7 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-hpwh.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-tankless.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-var-speed.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-dwhr.xml +567 -568
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-dse.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-outside.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-standbyloss.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-with-solar-fraction.xml +525 -528
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-electric.xml +567 -568
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-gas.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-hpwh.xml +566 -567
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-indirect.xml +522 -525
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-low-flow-fixtures.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-multiple.xml +575 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-none.xml +497 -497
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-demand.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-manual.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-nocontrol.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-temperature.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-timer.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-evacuated-tube.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-flat-plate.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-ics.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-fraction.xml +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-indirect-flat-plate.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-thermosyphon-flat-plate.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-coal.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-elec-uef.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-outside.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-uef.xml +565 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-outside.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-uef.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar-fraction.xml +569 -570
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-oil.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-wood.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-outside.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-uef.xml +561 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-uef.xml +561 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar-fraction.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-propane.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories-garage.xml +661 -664
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-1.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-2.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-4.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-5.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-garage.xml +636 -639
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-ach-house-pressure.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm-house-pressure.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm50.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-flue.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-natural-ach.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-overhangs.xml +582 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-rooftypes.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-shading.xml +601 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-level.xml +517 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-surfaces.xml +2474 -2493
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-surfaces2.xml +2475 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-walltypes.xml +754 -755
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-none.xml +504 -505
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-windows-interior-shading.xml → base-enclosure-windows-shading.xml} +23 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-ambient.xml +498 -497
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-basement-garage.xml +644 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-complex.xml +724 -729
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-slab-insulation.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-wall-interior-insulation.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-multiple.xml +685 -688
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-slab.xml +516 -517
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-above-grade.xml +609 -610
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-assembly-r.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-wall-insulation.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unvented-crawlspace.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-vented-crawlspace.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-walkout-basement.xml +627 -628
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-autosize.xml → base-hvac-air-to-air-heat-pump-1-speed-cooling-only.xml} +8 -12
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-1-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-air-to-air-heat-pump-1-speed-heating-only.xml} +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-2-speed.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-cooling-only.xml +553 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-1-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-1-speed-heating-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-manual-s-oversize-allowances.xml +561 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed.xml +558 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-2-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-air-to-air-heat-pump-2-speed-manual-s-oversize-allowances.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-2-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-2-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-var-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-air-to-air-heat-pump-var-speed-manual-s-oversize-allowances.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-var-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-var-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-elec-only-autosize.xml → base-hvac-autosize-boiler-elec-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-gas-central-ac-1-speed-autosize.xml → base-hvac-autosize-boiler-gas-central-ac-1-speed.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-gas-only-autosize.xml → base-hvac-autosize-boiler-gas-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-1-speed-autosize.xml → base-hvac-autosize-central-ac-only-1-speed.xml} +547 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-2-speed-autosize.xml → base-hvac-autosize-central-ac-only-2-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-var-speed-autosize.xml → base-hvac-autosize-central-ac-only-var-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-plus-air-to-air-heat-pump-heating-autosize.xml → base-hvac-autosize-central-ac-plus-air-to-air-heat-pump-heating.xml} +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed.xml +559 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-dual-fuel-mini-split-heat-pump-ducted-autosize.xml → base-hvac-autosize-dual-fuel-mini-split-heat-pump-ducted.xml} +557 -558
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-elec-resistance-only-autosize.xml → base-hvac-autosize-elec-resistance-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-evap-cooler-furnace-gas-autosize.xml → base-hvac-autosize-evap-cooler-furnace-gas.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-floor-furnace-propane-only-autosize.xml → base-hvac-autosize-floor-furnace-propane-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-elec-only-autosize.xml → base-hvac-autosize-furnace-elec-only.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-central-ac-2-speed-autosize.xml → base-hvac-autosize-furnace-gas-central-ac-2-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-central-ac-var-speed-autosize.xml → base-hvac-autosize-furnace-gas-central-ac-var-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-only-autosize.xml → base-hvac-autosize-furnace-gas-only.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-room-ac-autosize.xml → base-hvac-autosize-furnace-gas-room-ac.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-cooling-only.xml +555 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-heating-only.xml +560 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-ground-to-air-heat-pump-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-ground-to-air-heat-pump-manual-s-oversize-allowances.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-ground-to-air-heat-pump-autosize.xml → base-hvac-autosize-ground-to-air-heat-pump.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-air-conditioner-only-ducted.xml +547 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-cooling-only-autosize.xml → base-hvac-autosize-mini-split-heat-pump-ducted-cooling-only.xml} +551 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-heating-only-autosize.xml → base-hvac-autosize-mini-split-heat-pump-ducted-heating-only.xml} +556 -557
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-manual-s-oversize-allowances.xml +560 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-autosize.xml → base-hvac-autosize-mini-split-heat-pump-ducted.xml} +556 -557
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-room-ac-only-autosize.xml → base-hvac-autosize-room-ac-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-stove-oil-only-autosize.xml → base-hvac-autosize-stove-oil-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-wall-furnace-elec-only-autosize.xml → base-hvac-autosize-wall-furnace-elec-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-autosize.xml → base-hvac-autosize.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-coal-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-elec-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-central-ac-1-speed.xml +571 -573
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-only.xml +519 -522
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-oil-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-propane-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-wood-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-1-speed.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-2-speed.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-var-speed.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-plus-air-to-air-heat-pump-heating.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dse.xml +532 -535
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-electric.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-2-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-var-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-mini-split-heat-pump-ducted.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-leakage-percent.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-elec-resistance-only.xml +509 -512
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-furnace-gas.xml +555 -555
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only-ducted.xml +536 -528
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only.xml +503 -505
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fireplace-wood-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fixed-heater-gas-only.xml +6 -57
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-floor-furnace-propane-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-coal-only.xml +549 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-central-ac-1-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-2-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-var-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only.xml +5 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-room-ac.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-oil-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-propane-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-wood-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-x3-dse.xml +576 -579
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-cooling-only.xml +557 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-heating-only.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump.xml +7 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-flowrate.xml → base-hvac-install-quality-airflow-defect-furnace-gas-central-ac-1-speed.xml} +8 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{invalid_files/heat-pump-mixed-fixed-and-autosize-capacities2.xml → base-hvac-install-quality-all-air-to-air-heat-pump-1-speed.xml} +13 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-air-to-air-heat-pump-2-speed.xml +567 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-air-to-air-heat-pump-var-speed.xml +567 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-central-ac-1-speed.xml +572 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-central-ac-2-speed.xml +572 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-central-ac-var-speed.xml +572 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-only.xml +553 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-ground-to-air-heat-pump.xml +566 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-air-conditioner-only-ducted-autosize.xml → base-hvac-install-quality-all-mini-split-air-conditioner-only-ducted.xml} +10 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-autosize-manual-s-oversize-allowances.xml → base-hvac-install-quality-all-mini-split-heat-pump-ducted.xml} +13 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-blower-efficiency-furnace-gas-central-ac-1-speed.xml +569 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-misc-shelter-coefficient.xml → base-hvac-install-quality-charge-defect-furnace-gas-central-ac-1-speed.xml} +9 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-none-furnace-gas-central-ac-1-speed.xml +570 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ducted.xml +547 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ductless.xml +508 -511
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-cooling-only.xml +554 -555
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-heating-only.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless.xml +515 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-multiple.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-none.xml +486 -489
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-portable-heater-gas-only.xml +6 -57
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-programmable-thermostat-detailed.xml +567 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-programmable-thermostat.xml +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-33percent.xml +508 -511
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only.xml +508 -511
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-oil-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-wood-pellets-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized-allow-increased-fixed-capacities.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-wall-furnace-elec-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-ceiling-fans.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-detailed.xml +585 -586
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-none.xml +488 -489
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-AMY-2012.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-baltimore-md.xml +573 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-dallas-tx.xml +516 -517
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-duluth-mn.xml +573 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-helena-mt.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-honolulu-hi.xml +517 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-miami-fl.xml +516 -517
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-phoenix-az.xml +517 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-portland-or.xml +577 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-balanced.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-bath-kitchen-fans.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-dse.xml +545 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-evap-cooler-only-ducted.xml +549 -541
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv-atre-asre.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust-rated-flow-rate.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv-asre.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-multiple.xml +796 -795
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-supply.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-whole-house-fan.xml +572 -573
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-defaults.xml +478 -495
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators.xml +579 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon.xml +758 -833
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon2.xml +749 -820
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-none.xml +550 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-neighbor-shading.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/{invalid_files/invalid-calendar-year.xml → base-misc-shielding-of-home.xml} +7 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-usage-multiplier.xml +728 -725
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-multiple-buildings.xml +1657 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-stochastic-vacant.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-stochastic.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-user-specified.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-calendar-year-custom.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-custom.xml +569 -570
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-disabled.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-runperiod-1-month.xml +566 -567
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/boiler-invalid-afue.xml +519 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/cfis-with-hydronic-distribution.xml +532 -535
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/clothes-dryer-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/clothes-washer-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/cooking-range-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dehumidifier-fraction-served.xml +535 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dehumidifier-setpoints.xml +535 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dhw-frac-load-served.xml +575 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-dhw-uef.xml → invalid_files/dhw-invalid-ef-tank.xml} +7 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dhw-invalid-uef-tank-heat-pump.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dishwasher-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-leakage-cfm25.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-leakage-percent.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-location-unconditioned-space.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duplicate-id.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-attic-missing-roof.xml +546 -547
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-basement-missing-exterior-foundation-wall.xml +543 -544
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-basement-missing-slab.xml +546 -545
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-floor-area-exceeds-cfa.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-floor-area-exceeds-cfa2.xml +448 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-exterior-wall.xml +613 -616
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-roof-ceiling.xml +626 -629
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-slab.xml +610 -611
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-ceiling-roof.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-exterior-wall.xml +472 -473
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-floor-slab.xml +488 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-sensible-fuel-load.xml +760 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-sensible-plug-load.xml +759 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-total-fuel-load.xml +761 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-total-plug-load.xml +759 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/furnace-invalid-afue.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/generator-number-of-bedrooms-served.xml +460 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/generator-output-greater-than-consumption.xml +579 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/heat-pump-mixed-fixed-and-autosize-capacities.xml +559 -560
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-multiple-attached-cooling.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-multiple-attached-heating.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-return-duct-leakage-missing.xml +528 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-dse-multiple-attached-cooling.xml +546 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-dse-multiple-attached-heating.xml +546 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-frac-load-served.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-inconsistent-fan-powers.xml +569 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-invalid-distribution-system-type.xml +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-shared-negative-seer-eq.xml +407 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-assembly-effective-rvalue.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-boolean.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-float.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-integer.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-daylight-saving.xml +569 -567
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-distribution-cfa-served.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-epw-filepath.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-facility-type-equipment.xml +466 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-facility-type-surfaces.xml +644 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/{appliances-location-unconditioned-space.xml → invalid-foundation-wall-properties.xml} +39 -29
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-id.xml +591 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-id2.xml +591 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-infiltration-volume.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-input-parameters.xml +565 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-neighbor-shading-azimuth.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-number-of-bedrooms-served.xml +465 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/{slab-zero-exposed-perimeter.xml → invalid-number-of-conditioned-floors.xml} +7 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-number-of-units-served.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-relatedhvac-desuperheater.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-relatedhvac-dhw-indirect.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-runperiod.xml +564 -565
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-schema-version.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-shared-vent-in-unit-flowrate.xml +473 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-timestep.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-window-height.xml +582 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/lighting-fractions.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/missing-duct-location.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/missing-elements.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-appliance.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-duct.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-surface.xml +575 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-water-heater.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-buildings-without-building-id.xml +1657 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-buildings-wrong-building-id.xml +1657 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-shared-cooling-systems.xml +432 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-shared-heating-systems.xml +434 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/net-area-negative-roof.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/net-area-negative-wall.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/num-bedrooms-exceeds-limit.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/orphaned-hvac-distribution.xml +546 -547
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerator-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerators-multiple-primary.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerators-no-primary.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/repeated-relatedhvac-desuperheater.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/repeated-relatedhvac-dhw-indirect.xml +526 -529
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-fraction-one.xml +571 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-combi-tankless.xml +531 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-desuperheater.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-dhw-indirect.xml +531 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-cfis.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-door.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-hvac-distribution.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-shared-clothes-washer-water-heater.xml +465 -827
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-shared-dishwasher-water-heater.xml +465 -827
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-skylight.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-solar-thermal-system.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-window.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/water-heater-location-other.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/water-heater-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/template.osw +5 -1
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L302XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L304XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L322XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L324XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results.csv +294 -0
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_ashrae_140.csv +27 -0
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_hvac_sizing.csv +294 -0
- data/example_files/resources/hpxml-measures/workflow/tests/compare.rb +130 -0
- data/example_files/resources/hpxml-measures/workflow/tests/hpxml_translator_test.rb +522 -527
- data/example_files/{measures/BuildResidentialModel/resources → resources}/measure-info.json +0 -0
- data/example_files/{measures/BuildResidentialModel/resources → resources}/meta_measure.rb +53 -44
- data/example_files/validation_schema.yaml +149 -0
- data/example_files/visualization/input_visualization_feature.html +213 -56
- data/example_files/visualization/input_visualization_scenario.html +92 -30
- data/lib/uo_cli.rb +406 -128
- data/lib/uo_cli/version.rb +17 -7
- data/requirements.txt +2 -0
- data/scripts/setup-env-gitbash.sh +5 -5
- data/scripts/setup-env-unix.sh +4 -4
- data/scripts/setup-env.bat +14 -11
- data/scripts/setup-env.ps1 +13 -10
- data/uo_cli.gemspec +10 -8
- metadata +390 -130
- data/developer_nrel_key.rb +0 -31
- data/example_files/measures/ResidentialGeometryCreateMultifamily/measure.rb +0 -1005
- data/example_files/measures/ResidentialGeometryCreateMultifamily/measure.xml +0 -326
- data/example_files/measures/ResidentialGeometryCreateMultifamily/tests/create_residential_multifamily_geometry_test.rb +0 -477
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/measure.rb +0 -1039
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/measure.xml +0 -393
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/tests/create_residential_single_family_attached_geometry_test.rb +0 -456
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/measure.rb +0 -979
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/measure.xml +0 -388
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/tests/create_residential_single_family_detached_geometry_test.rb +0 -704
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/location.rb +0 -24
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_config.yml +0 -61
- data/example_files/resources/hpxml-measures/docs/source/hpxml_to_openstudio.rst +0 -1386
- data/example_files/resources/hpxml-measures/docs/source/simulation_output_report.rst +0 -252
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-shared-laundry-room.xml +0 -828
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-shared-water-heater-recirc.xml +0 -820
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-shared-water-heater.xml +0 -813
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-attached-multifamily.xml +0 -810
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-common-surfaces.xml +0 -928
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ideal-air.xml +0 -501
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-multiple2.xml +0 -838
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-baseboard.xml +0 -777
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-fan-coil-ducted.xml +0 -808
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-fan-coil.xml +0 -780
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-water-loop-heat-pump.xml +0 -820
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-cooling-tower-water-loop-heat-pump.xml +0 -815
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-baseboard.xml +0 -760
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-fan-coil-ducted.xml +0 -790
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-fan-coil-eae.xml +0 -759
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-fan-coil.xml +0 -762
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-water-loop-heat-pump.xml +0 -796
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-baseboard.xml +0 -759
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-fan-coil-ducted.xml +0 -789
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-fan-coil.xml +0 -761
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-water-loop-heat-pump.xml +0 -796
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-cooling-tower-only-water-loop-heat-pump.xml +0 -791
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-ground-loop-ground-to-air-heat-pump.xml +0 -814
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-shared-preconditioning.xml +0 -851
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-shared.xml +0 -835
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-shared.xml +0 -827
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/coal-for-non-boiler-heating.xml +0 -514
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-facility-type.xml +0 -828
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-window-interior-shading.xml +0 -564
@@ -8,7 +8,6 @@ class Lighting
|
|
8
8
|
end
|
9
9
|
|
10
10
|
if fractions[[HPXML::LocationInterior, HPXML::LightingTypeCFL]].nil? # Not the lighting group(s) we're interested in
|
11
|
-
runner.registerWarning('No lighting specified, the model will not include lighting energy use.')
|
12
11
|
return
|
13
12
|
end
|
14
13
|
|
@@ -49,7 +48,7 @@ class Lighting
|
|
49
48
|
garage_sch = MonthWeekdayWeekendSchedule.new(model, Constants.ObjectNameGarageLighting + ' schedule', lighting.garage_weekday_fractions, lighting.garage_weekend_fractions, lighting.garage_monthly_multipliers, Constants.ScheduleTypeLimitsFraction)
|
50
49
|
end
|
51
50
|
if not lighting.holiday_kwh_per_day.nil?
|
52
|
-
exterior_holiday_sch = MonthWeekdayWeekendSchedule.new(model, Constants.ObjectNameLightingExteriorHoliday + ' schedule', lighting.holiday_weekday_fractions, lighting.holiday_weekend_fractions, lighting.exterior_monthly_multipliers, Constants.ScheduleTypeLimitsFraction, true, lighting.holiday_period_begin_month, lighting.
|
51
|
+
exterior_holiday_sch = MonthWeekdayWeekendSchedule.new(model, Constants.ObjectNameLightingExteriorHoliday + ' schedule', lighting.holiday_weekday_fractions, lighting.holiday_weekend_fractions, lighting.exterior_monthly_multipliers, Constants.ScheduleTypeLimitsFraction, true, lighting.holiday_period_begin_month, lighting.holiday_period_begin_day, lighting.holiday_period_end_month, lighting.holiday_period_end_day)
|
53
52
|
end
|
54
53
|
|
55
54
|
# Add lighting to each conditioned space
|
@@ -120,6 +119,7 @@ class Lighting
|
|
120
119
|
ltg_def = OpenStudio::Model::ExteriorLightsDefinition.new(model)
|
121
120
|
ltg = OpenStudio::Model::ExteriorLights.new(ltg_def)
|
122
121
|
ltg.setName(Constants.ObjectNameExteriorLighting)
|
122
|
+
ltg.setEndUseSubcategory(Constants.ObjectNameExteriorLighting)
|
123
123
|
ltg_def.setName(Constants.ObjectNameExteriorLighting)
|
124
124
|
ltg_def.setDesignLevel(design_level)
|
125
125
|
ltg.setSchedule(exterior_sch)
|
@@ -139,6 +139,7 @@ class Lighting
|
|
139
139
|
ltg_def = OpenStudio::Model::ExteriorLightsDefinition.new(model)
|
140
140
|
ltg = OpenStudio::Model::ExteriorLights.new(ltg_def)
|
141
141
|
ltg.setName(Constants.ObjectNameLightingExteriorHoliday)
|
142
|
+
ltg.setEndUseSubcategory(Constants.ObjectNameLightingExteriorHoliday)
|
142
143
|
ltg_def.setName(Constants.ObjectNameLightingExteriorHoliday)
|
143
144
|
ltg_def.setDesignLevel(design_level)
|
144
145
|
ltg.setSchedule(exterior_holiday_sch)
|
@@ -7,7 +7,6 @@ class Location
|
|
7
7
|
apply_climate_zones(model, epw_file)
|
8
8
|
apply_dst(model, hpxml)
|
9
9
|
apply_ground_temps(model, weather)
|
10
|
-
return weather
|
11
10
|
end
|
12
11
|
|
13
12
|
def self.apply_weather_file(model, runner, weather_file_path, weather_cache_path)
|
@@ -59,8 +58,8 @@ class Location
|
|
59
58
|
return unless hpxml.header.dst_enabled
|
60
59
|
|
61
60
|
month_names = ['Jan', 'Feb', 'Mar', 'Apr', 'May', 'Jun', 'Jul', 'Aug', 'Sep', 'Oct', 'Nov', 'Dec']
|
62
|
-
dst_start_date = "#{month_names[hpxml.header.dst_begin_month - 1]} #{hpxml.header.
|
63
|
-
dst_end_date = "#{month_names[hpxml.header.dst_end_month - 1]} #{hpxml.header.
|
61
|
+
dst_start_date = "#{month_names[hpxml.header.dst_begin_month - 1]} #{hpxml.header.dst_begin_day}"
|
62
|
+
dst_end_date = "#{month_names[hpxml.header.dst_end_month - 1]} #{hpxml.header.dst_end_day}"
|
64
63
|
|
65
64
|
run_period_control_daylight_saving_time = model.getRunPeriodControlDaylightSavingTime
|
66
65
|
run_period_control_daylight_saving_time.setStartDate(dst_start_date)
|
@@ -79,21 +78,34 @@ class Location
|
|
79
78
|
dgts.setAllMonthlyTemperatures([UnitConversions.convert(weather.data.AnnualAvgDrybulb, 'F', 'C')] * 12)
|
80
79
|
end
|
81
80
|
|
82
|
-
def self.
|
83
|
-
ba_zone = nil
|
81
|
+
def self.get_climate_zones
|
84
82
|
zones_csv = File.join(File.dirname(__FILE__), 'data_climate_zones.csv')
|
85
83
|
if not File.exist?(zones_csv)
|
86
84
|
fail 'Could not find data_climate_zones.csv'
|
87
85
|
end
|
88
86
|
|
87
|
+
return zones_csv
|
88
|
+
end
|
89
|
+
|
90
|
+
def self.get_climate_zone_iecc(wmo)
|
91
|
+
zones_csv = get_climate_zones
|
92
|
+
|
93
|
+
require 'csv'
|
94
|
+
CSV.foreach(zones_csv) do |row|
|
95
|
+
return row[6].to_s if row[0].to_s == wmo.to_s
|
96
|
+
end
|
97
|
+
|
98
|
+
return
|
99
|
+
end
|
100
|
+
|
101
|
+
def self.get_climate_zone_ba(wmo)
|
102
|
+
zones_csv = get_climate_zones
|
103
|
+
|
89
104
|
require 'csv'
|
90
105
|
CSV.foreach(zones_csv) do |row|
|
91
|
-
if row[0].to_s == wmo.to_s
|
92
|
-
ba_zone = row[5].to_s
|
93
|
-
break
|
94
|
-
end
|
106
|
+
return row[5].to_s if row[0].to_s == wmo.to_s
|
95
107
|
end
|
96
108
|
|
97
|
-
return
|
109
|
+
return
|
98
110
|
end
|
99
111
|
end
|
@@ -2,8 +2,9 @@
|
|
2
2
|
|
3
3
|
require 'fileutils'
|
4
4
|
|
5
|
-
def run_hpxml_workflow(rundir,
|
6
|
-
output_meters: [], run_measures_only: false, print_prefix: ''
|
5
|
+
def run_hpxml_workflow(rundir, measures, measures_dir, debug: false, output_vars: [],
|
6
|
+
output_meters: [], run_measures_only: false, print_prefix: '',
|
7
|
+
ep_input_format: 'idf')
|
7
8
|
rm_path(rundir)
|
8
9
|
FileUtils.mkdir_p(rundir)
|
9
10
|
|
@@ -47,23 +48,38 @@ def run_hpxml_workflow(rundir, hpxml, measures, measures_dir, debug: false, outp
|
|
47
48
|
om.setReportingFrequency(output_meter[1])
|
48
49
|
end
|
49
50
|
|
50
|
-
# Translate model to
|
51
|
+
# Translate model to workspace
|
51
52
|
forward_translator = OpenStudio::EnergyPlus::ForwardTranslator.new
|
52
53
|
forward_translator.setExcludeLCCObjects(true)
|
53
|
-
|
54
|
-
report_ft_errors_warnings(forward_translator, rundir)
|
54
|
+
workspace = forward_translator.translateModel(model)
|
55
|
+
success = report_ft_errors_warnings(forward_translator, rundir)
|
55
56
|
|
56
|
-
|
57
|
-
|
57
|
+
if not success
|
58
|
+
print "#{print_prefix}Creating input unsuccessful.\n"
|
59
|
+
print "#{print_prefix}See #{File.join(rundir, 'run.log')} for details.\n"
|
60
|
+
return { success: false, runner: runner }
|
61
|
+
end
|
58
62
|
|
59
|
-
#
|
60
|
-
|
63
|
+
# Apply reporting measure output requests
|
64
|
+
apply_energyplus_output_requests(measures_dir, measures, runner, model, workspace)
|
65
|
+
|
66
|
+
# Write to file
|
67
|
+
if ep_input_format == 'idf'
|
68
|
+
ep_input_filename = 'in.idf'
|
69
|
+
File.open(File.join(rundir, ep_input_filename), 'w') { |f| f << workspace.to_s }
|
70
|
+
elsif ep_input_format == 'epjson'
|
71
|
+
ep_input_filename = 'in.epJSON'
|
72
|
+
json = OpenStudio::EPJSON::toJSONString(workspace.toIdfFile)
|
73
|
+
File.open(File.join(rundir, ep_input_filename), 'w') { |f| f << json.to_s }
|
74
|
+
else
|
75
|
+
fail "Unexpected ep_input_format: #{ep_input_format}."
|
76
|
+
end
|
61
77
|
|
62
78
|
# Run simulation
|
63
79
|
print "#{print_prefix}Running simulation...\n"
|
64
80
|
ep_path = File.absolute_path(File.join(OpenStudio.getOpenStudioCLI.to_s, '..', '..', 'EnergyPlus', 'energyplus')) # getEnergyPlusDirectory can be unreliable, using getOpenStudioCLI instead
|
65
81
|
simulation_start = Time.now
|
66
|
-
command = "\"#{ep_path}\" -w \"#{model.getWeatherFile.path.get}\"
|
82
|
+
command = "\"#{ep_path}\" -w \"#{model.getWeatherFile.path.get}\" #{ep_input_filename}"
|
67
83
|
if debug
|
68
84
|
File.open(File.join(rundir, 'run.log'), 'a') do |f|
|
69
85
|
f << "Executing command '#{command}' from working directory '#{rundir}'.\n"
|
@@ -130,8 +146,6 @@ def run_hpxml_workflow(rundir, hpxml, measures, measures_dir, debug: false, outp
|
|
130
146
|
end
|
131
147
|
|
132
148
|
def apply_measures(measures_dir, measures, runner, model, show_measure_calls = true, measure_type = 'OpenStudio::Measure::ModelMeasure')
|
133
|
-
require 'openstudio'
|
134
|
-
|
135
149
|
# Call each measure in the specified order
|
136
150
|
measures.keys.each do |measure_subdir|
|
137
151
|
# Gather measure arguments and call measure
|
@@ -155,7 +169,7 @@ def apply_measures(measures_dir, measures, runner, model, show_measure_calls = t
|
|
155
169
|
return true
|
156
170
|
end
|
157
171
|
|
158
|
-
def apply_energyplus_output_requests(measures_dir, measures, runner, model,
|
172
|
+
def apply_energyplus_output_requests(measures_dir, measures, runner, model, workspace)
|
159
173
|
# Call each measure in the specified order
|
160
174
|
measures.keys.each do |measure_subdir|
|
161
175
|
# Gather measure arguments and call measure
|
@@ -169,7 +183,7 @@ def apply_energyplus_output_requests(measures_dir, measures, runner, model, mode
|
|
169
183
|
runner.setLastOpenStudioModel(model)
|
170
184
|
idf_objects = measure.energyPlusOutputRequests(runner, argument_map)
|
171
185
|
idf_objects.each do |idf_object|
|
172
|
-
|
186
|
+
workspace.addObject(idf_object)
|
173
187
|
end
|
174
188
|
end
|
175
189
|
end
|
@@ -261,7 +275,6 @@ def validate_measure_args(measure_args, provided_args, lookup_file, measure_name
|
|
261
275
|
end
|
262
276
|
|
263
277
|
def get_argument_map(model, measure, provided_args, lookup_file, measure_name, runner = nil)
|
264
|
-
require 'openstudio'
|
265
278
|
measure_args = measure.arguments(model)
|
266
279
|
provided_args = validate_measure_args(measure_args, provided_args, lookup_file, measure_name, runner)
|
267
280
|
|
@@ -277,8 +290,20 @@ def get_argument_map(model, measure, provided_args, lookup_file, measure_name, r
|
|
277
290
|
return argument_map
|
278
291
|
end
|
279
292
|
|
293
|
+
def get_value_from_workflow_step_value(step_value)
|
294
|
+
variant_type = step_value.variantType
|
295
|
+
if variant_type == 'Boolean'.to_VariantType
|
296
|
+
return step_value.valueAsBoolean
|
297
|
+
elsif variant_type == 'Double'.to_VariantType
|
298
|
+
return step_value.valueAsDouble
|
299
|
+
elsif variant_type == 'Integer'.to_VariantType
|
300
|
+
return step_value.valueAsInteger
|
301
|
+
elsif variant_type == 'String'.to_VariantType
|
302
|
+
return step_value.valueAsString
|
303
|
+
end
|
304
|
+
end
|
305
|
+
|
280
306
|
def run_measure(model, measure, argument_map, runner)
|
281
|
-
require 'openstudio'
|
282
307
|
begin
|
283
308
|
# run the measure
|
284
309
|
runner_child = OpenStudio::Measure::OSRunner.new(OpenStudio::WorkflowJSON.new)
|
@@ -302,6 +327,11 @@ def run_measure(model, measure, argument_map, runner)
|
|
302
327
|
runner.registerFinalCondition(result_child.finalCondition.get.logMessage)
|
303
328
|
end
|
304
329
|
|
330
|
+
# re-register runner child registered values on the parent runner
|
331
|
+
result_child.stepValues.each do |step_value|
|
332
|
+
runner.registerValue(step_value.name, get_value_from_workflow_step_value(step_value))
|
333
|
+
end
|
334
|
+
|
305
335
|
# log messages
|
306
336
|
result_child.warnings.each do |warning|
|
307
337
|
runner.registerWarning(warning.logMessage)
|
@@ -342,7 +372,7 @@ end
|
|
342
372
|
def register_error(msg, runner = nil)
|
343
373
|
if not runner.nil?
|
344
374
|
runner.registerError(msg)
|
345
|
-
fail msg
|
375
|
+
fail msg
|
346
376
|
else
|
347
377
|
raise "ERROR: #{msg}"
|
348
378
|
end
|
@@ -392,14 +422,17 @@ end
|
|
392
422
|
|
393
423
|
def report_ft_errors_warnings(forward_translator, rundir)
|
394
424
|
# Report warnings/errors
|
425
|
+
success = true
|
395
426
|
File.open(File.join(rundir, 'run.log'), 'a') do |f|
|
396
427
|
forward_translator.warnings.each do |s|
|
397
428
|
f << "FT Warning: #{s.logMessage}\n"
|
398
429
|
end
|
399
430
|
forward_translator.errors.each do |s|
|
400
431
|
f << "FT Error: #{s.logMessage}\n"
|
432
|
+
success = false
|
401
433
|
end
|
402
434
|
end
|
435
|
+
return success
|
403
436
|
end
|
404
437
|
|
405
438
|
def report_os_warnings(os_log, rundir)
|
@@ -409,9 +442,8 @@ def report_os_warnings(os_log, rundir)
|
|
409
442
|
next if s.logMessage.include? 'Data will be treated as typical (TMY)'
|
410
443
|
next if s.logMessage.include? 'WorkflowStepResult value called with undefined stepResult'
|
411
444
|
next if s.logMessage.include?("Object of type 'Schedule:Constant' and named 'Always") && s.logMessage.include?('points to an object named') && s.logMessage.include?('but that object cannot be located')
|
412
|
-
# TODO: Remove once https://github.com/NREL/OpenStudio/pull/3999 is available
|
413
|
-
next if s.logMessage.include? "'Propane' is deprecated for Coil_Heating_GasFields:FuelType, use 'Propane' instead"
|
414
445
|
next if s.logMessage.include? 'Appears there are no design condition fields in the EPW file'
|
446
|
+
next if s.logMessage.include?('Using EnergyPlusVersion version') && s.logMessage.include?("which should have 'Year' field, but it's always zero")
|
415
447
|
|
416
448
|
f << "OS Message: #{s.logMessage}\n"
|
417
449
|
end
|
@@ -446,3 +478,37 @@ class String
|
|
446
478
|
return true
|
447
479
|
end
|
448
480
|
end
|
481
|
+
|
482
|
+
def get_argument_values(runner, arguments, user_arguments)
|
483
|
+
args = {}
|
484
|
+
arguments.each do |argument|
|
485
|
+
if argument.required
|
486
|
+
case argument.type
|
487
|
+
when 'Choice'.to_OSArgumentType
|
488
|
+
args[argument.name] = runner.getStringArgumentValue(argument.name, user_arguments)
|
489
|
+
when 'Boolean'.to_OSArgumentType
|
490
|
+
args[argument.name] = runner.getBoolArgumentValue(argument.name, user_arguments)
|
491
|
+
when 'Double'.to_OSArgumentType
|
492
|
+
args[argument.name] = runner.getDoubleArgumentValue(argument.name, user_arguments)
|
493
|
+
when 'Integer'.to_OSArgumentType
|
494
|
+
args[argument.name] = runner.getIntegerArgumentValue(argument.name, user_arguments)
|
495
|
+
when 'String'.to_OSArgumentType
|
496
|
+
args[argument.name] = runner.getStringArgumentValue(argument.name, user_arguments)
|
497
|
+
end
|
498
|
+
else
|
499
|
+
case argument.type
|
500
|
+
when 'Choice'.to_OSArgumentType
|
501
|
+
args[argument.name] = runner.getOptionalStringArgumentValue(argument.name, user_arguments)
|
502
|
+
when 'Boolean'.to_OSArgumentType
|
503
|
+
args[argument.name] = runner.getOptionalStringArgumentValue(argument.name, user_arguments)
|
504
|
+
when 'Double'.to_OSArgumentType
|
505
|
+
args[argument.name] = runner.getOptionalDoubleArgumentValue(argument.name, user_arguments)
|
506
|
+
when 'Integer'.to_OSArgumentType
|
507
|
+
args[argument.name] = runner.getOptionalIntegerArgumentValue(argument.name, user_arguments)
|
508
|
+
when 'String'.to_OSArgumentType
|
509
|
+
args[argument.name] = runner.getOptionalStringArgumentValue(argument.name, user_arguments)
|
510
|
+
end
|
511
|
+
end
|
512
|
+
end
|
513
|
+
return args
|
514
|
+
end
|
@@ -1,30 +1,8 @@
|
|
1
1
|
# frozen_string_literal: true
|
2
2
|
|
3
|
-
|
4
|
-
begin
|
5
|
-
OpenStudio.getOpenStudioCLI
|
6
|
-
rescue
|
7
|
-
called_from_cli = false
|
8
|
-
end
|
3
|
+
require 'minitest/autorun'
|
9
4
|
|
10
|
-
|
11
|
-
|
12
|
-
require 'codecov'
|
5
|
+
require 'minitest/reporters'
|
6
|
+
require 'minitest/reporters/spec_reporter' # Needed when run via OS CLI
|
13
7
|
|
14
|
-
|
15
|
-
if ENV['CI']
|
16
|
-
if ENV['CIRCLE_ARTIFACTS']
|
17
|
-
dir = File.join(ENV['CIRCLE_ARTIFACTS'], 'coverage')
|
18
|
-
SimpleCov.coverage_dir(dir)
|
19
|
-
end
|
20
|
-
SimpleCov.formatter = SimpleCov::Formatter::Codecov
|
21
|
-
else
|
22
|
-
SimpleCov.coverage_dir('coverage')
|
23
|
-
end
|
24
|
-
SimpleCov.start
|
25
|
-
|
26
|
-
require 'minitest/autorun'
|
27
|
-
require 'minitest/reporters'
|
28
|
-
|
29
|
-
Minitest::Reporters.use! Minitest::Reporters::SpecReporter.new # spec-like progress
|
30
|
-
end
|
8
|
+
Minitest::Reporters.use! Minitest::Reporters::SpecReporter.new # spec-like progress
|
@@ -1,7 +1,7 @@
|
|
1
1
|
# frozen_string_literal: true
|
2
2
|
|
3
3
|
class MiscLoads
|
4
|
-
def self.apply_plug(model, plug_load, obj_name, living_space, schedules_file)
|
4
|
+
def self.apply_plug(model, plug_load, obj_name, living_space, apply_ashrae140_assumptions, schedules_file)
|
5
5
|
kwh = 0
|
6
6
|
|
7
7
|
if not plug_load.nil?
|
@@ -30,21 +30,11 @@ class MiscLoads
|
|
30
30
|
sens_frac = plug_load.frac_sensible
|
31
31
|
lat_frac = plug_load.frac_latent
|
32
32
|
|
33
|
-
|
34
|
-
|
35
|
-
|
36
|
-
|
37
|
-
|
38
|
-
fail 'Latent fraction must be greater than or equal to 0 and less than or equal to 1.'
|
39
|
-
end
|
40
|
-
if lat_frac + sens_frac > 1
|
41
|
-
fail 'Sum of sensible and latent fractions must be less than or equal to 1.'
|
42
|
-
end
|
43
|
-
|
44
|
-
if plug_load.location == HPXML::LocationExterior
|
45
|
-
# Set all heat gain as lost
|
46
|
-
sens_frac = 0.0
|
47
|
-
lat_fract = 0.0
|
33
|
+
if apply_ashrae140_assumptions
|
34
|
+
# ASHRAE 140, Table 7-9. Sensible loads are 70% radiative and 30% convective.
|
35
|
+
rad_frac = 0.7 * sens_frac
|
36
|
+
else
|
37
|
+
rad_frac = 0.6 * sens_frac
|
48
38
|
end
|
49
39
|
|
50
40
|
# Add electric equipment for the mel
|
@@ -55,7 +45,7 @@ class MiscLoads
|
|
55
45
|
mel.setSpace(living_space)
|
56
46
|
mel_def.setName(obj_name)
|
57
47
|
mel_def.setDesignLevel(space_design_level)
|
58
|
-
mel_def.setFractionRadiant(
|
48
|
+
mel_def.setFractionRadiant(rad_frac)
|
59
49
|
mel_def.setFractionLatent(lat_frac)
|
60
50
|
mel_def.setFractionLost(1 - sens_frac - lat_frac)
|
61
51
|
mel.setSchedule(sch)
|
@@ -88,29 +78,12 @@ class MiscLoads
|
|
88
78
|
sens_frac = fuel_load.frac_sensible
|
89
79
|
lat_frac = fuel_load.frac_latent
|
90
80
|
|
91
|
-
# check for valid inputs
|
92
|
-
if (sens_frac < 0) || (sens_frac > 1)
|
93
|
-
fail 'Sensible fraction must be greater than or equal to 0 and less than or equal to 1.'
|
94
|
-
end
|
95
|
-
if (lat_frac < 0) || (lat_frac > 1)
|
96
|
-
fail 'Latent fraction must be greater than or equal to 0 and less than or equal to 1.'
|
97
|
-
end
|
98
|
-
if lat_frac + sens_frac > 1
|
99
|
-
fail 'Sum of sensible and latent fractions must be less than or equal to 1.'
|
100
|
-
end
|
101
|
-
|
102
|
-
if fuel_load.location == HPXML::LocationExterior
|
103
|
-
# Set all heat gain as lost
|
104
|
-
sens_frac = 0.0
|
105
|
-
lat_fract = 0.0
|
106
|
-
end
|
107
|
-
|
108
81
|
# Add other equipment for the mfl
|
109
82
|
mfl_def = OpenStudio::Model::OtherEquipmentDefinition.new(model)
|
110
83
|
mfl = OpenStudio::Model::OtherEquipment.new(mfl_def)
|
111
84
|
mfl.setName(obj_name)
|
112
85
|
mfl.setEndUseSubcategory(obj_name)
|
113
|
-
mfl.setFuelType(EPlus.
|
86
|
+
mfl.setFuelType(EPlus.fuel_type(fuel_load.fuel_type))
|
114
87
|
mfl.setSpace(living_space)
|
115
88
|
mfl_def.setName(obj_name)
|
116
89
|
mfl_def.setDesignLevel(space_design_level)
|
@@ -121,6 +94,8 @@ class MiscLoads
|
|
121
94
|
end
|
122
95
|
|
123
96
|
def self.apply_pool_or_hot_tub_heater(model, pool_or_hot_tub, obj_name, living_space, schedules_file)
|
97
|
+
return if pool_or_hot_tub.heater_type == HPXML::TypeNone
|
98
|
+
|
124
99
|
heater_kwh = 0
|
125
100
|
heater_therm = 0
|
126
101
|
|
@@ -170,17 +145,18 @@ class MiscLoads
|
|
170
145
|
heater_sch = heater_sch.schedule
|
171
146
|
end
|
172
147
|
|
173
|
-
|
174
|
-
|
175
|
-
|
176
|
-
|
177
|
-
|
178
|
-
|
179
|
-
|
180
|
-
|
181
|
-
|
182
|
-
|
183
|
-
|
148
|
+
mfl_def = OpenStudio::Model::OtherEquipmentDefinition.new(model)
|
149
|
+
mfl = OpenStudio::Model::OtherEquipment.new(mfl_def)
|
150
|
+
mfl.setName(obj_name)
|
151
|
+
mfl.setEndUseSubcategory(obj_name)
|
152
|
+
mfl.setFuelType(EPlus.fuel_type(HPXML::FuelTypeNaturalGas))
|
153
|
+
mfl.setSpace(living_space)
|
154
|
+
mfl_def.setName(obj_name)
|
155
|
+
mfl_def.setDesignLevel(space_design_level)
|
156
|
+
mfl_def.setFractionRadiant(0)
|
157
|
+
mfl_def.setFractionLatent(0)
|
158
|
+
mfl_def.setFractionLost(1)
|
159
|
+
mfl.setSchedule(heater_sch)
|
184
160
|
end
|
185
161
|
end
|
186
162
|
|
@@ -8,42 +8,43 @@ class PV
|
|
8
8
|
max_power = pv_system.max_power_output
|
9
9
|
else
|
10
10
|
# Apportion to single dwelling unit by # bedrooms
|
11
|
+
fail if pv_system.number_of_bedrooms_served.to_f <= nbeds.to_f # EPvalidator.xml should prevent this
|
12
|
+
|
11
13
|
max_power = pv_system.max_power_output * nbeds.to_f / pv_system.number_of_bedrooms_served.to_f
|
12
14
|
end
|
13
15
|
|
14
|
-
|
15
|
-
|
16
|
-
|
17
|
-
|
18
|
-
|
16
|
+
gpvwatts = OpenStudio::Model::GeneratorPVWatts.new(model, max_power)
|
17
|
+
gpvwatts.setName("#{obj_name} generator")
|
18
|
+
gpvwatts.setSystemLosses(pv_system.system_losses_fraction)
|
19
|
+
gpvwatts.setTiltAngle(pv_system.array_tilt)
|
20
|
+
gpvwatts.setAzimuthAngle(pv_system.array_azimuth)
|
19
21
|
if (pv_system.tracking == HPXML::PVTrackingTypeFixed) && (pv_system.location == HPXML::LocationRoof)
|
20
|
-
|
22
|
+
gpvwatts.setArrayType('FixedRoofMounted')
|
21
23
|
elsif (pv_system.tracking == HPXML::PVTrackingTypeFixed) && (pv_system.location == HPXML::LocationGround)
|
22
|
-
|
24
|
+
gpvwatts.setArrayType('FixedOpenRack')
|
23
25
|
elsif pv_system.tracking == HPXML::PVTrackingType1Axis
|
24
|
-
|
26
|
+
gpvwatts.setArrayType('OneAxis')
|
25
27
|
elsif pv_system.tracking == HPXML::PVTrackingType1AxisBacktracked
|
26
|
-
|
28
|
+
gpvwatts.setArrayType('OneAxisBacktracking')
|
27
29
|
elsif pv_system.tracking == HPXML::PVTrackingType2Axis
|
28
|
-
|
30
|
+
gpvwatts.setArrayType('TwoAxis')
|
29
31
|
end
|
30
32
|
if pv_system.module_type == HPXML::PVModuleTypeStandard
|
31
|
-
|
33
|
+
gpvwatts.setModuleType('Standard')
|
32
34
|
elsif pv_system.module_type == HPXML::PVModuleTypePremium
|
33
|
-
|
35
|
+
gpvwatts.setModuleType('Premium')
|
34
36
|
elsif pv_system.module_type == HPXML::PVModuleTypeThinFilm
|
35
|
-
|
37
|
+
gpvwatts.setModuleType('ThinFilm')
|
36
38
|
end
|
37
39
|
|
38
|
-
|
39
|
-
|
40
|
-
|
41
|
-
inverter = OpenStudio::Model::ElectricLoadCenterInverterPVWatts.new(model)
|
42
|
-
inverter.setName("#{obj_name} inverter")
|
43
|
-
inverter.setInverterEfficiency(pv_system.inverter_efficiency)
|
40
|
+
ipvwatts = OpenStudio::Model::ElectricLoadCenterInverterPVWatts.new(model)
|
41
|
+
ipvwatts.setName("#{obj_name} inverter")
|
42
|
+
ipvwatts.setInverterEfficiency(pv_system.inverter_efficiency)
|
44
43
|
|
45
|
-
|
46
|
-
|
44
|
+
elcd = OpenStudio::Model::ElectricLoadCenterDistribution.new(model)
|
45
|
+
elcd.setName("#{obj_name} elec load center dist")
|
46
|
+
elcd.addGenerator(gpvwatts)
|
47
|
+
elcd.setInverter(ipvwatts)
|
47
48
|
end
|
48
49
|
|
49
50
|
def self.calc_module_power_from_year(year_modules_manufactured)
|