urbanopt-cli 0.4.1 → 0.6.1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/.gitignore +3 -1
- data/CHANGELOG.md +59 -0
- data/CMakeLists.txt +17 -17
- data/FindOpenStudioSDK.cmake +12 -7
- data/Gemfile +8 -10
- data/LICENSE.md +11 -1
- data/README.md +1 -0
- data/Rakefile +16 -6
- data/example_files/Gemfile +25 -9
- data/example_files/example_project.json +35 -20
- data/example_files/example_project_combined.json +100 -5
- data/example_files/example_project_with_electric_network.json +2116 -0
- data/example_files/mappers/Baseline.rb +111 -51
- data/example_files/mappers/CreateBar.rb +19 -7
- data/example_files/mappers/EvCharging.rb +141 -0
- data/example_files/mappers/Floorspace.rb +29 -17
- data/example_files/mappers/HighEfficiency.rb +20 -8
- data/example_files/mappers/HighEfficiencyCreateBar.rb +19 -8
- data/example_files/mappers/HighEfficiencyFloorspace.rb +19 -8
- data/example_files/mappers/ThermalStorage.rb +16 -6
- data/example_files/mappers/base_workflow.osw +26 -1
- data/example_files/mappers/floorspace_workflow.osw +9 -0
- data/example_files/measures/BuildResidentialModel/measure.rb +249 -134
- data/example_files/reopt/base_assumptions.json +2 -2
- data/example_files/reopt/multiPV_assumptions.json +4 -3
- data/example_files/residential/clothes_dryer.tsv +7 -7
- data/example_files/residential/clothes_washer.tsv +2 -2
- data/example_files/residential/cooling_system.tsv +42 -22
- data/example_files/residential/dishwasher.tsv +1 -1
- data/example_files/residential/exhaust.tsv +3 -0
- data/example_files/residential/heat_pump.tsv +62 -40
- data/example_files/residential/water_heater.tsv +1 -1
- data/example_files/resources/hpxml-measures/.github/pull_request_template.md +14 -0
- data/example_files/resources/hpxml-measures/.github/workflows/config.yml +116 -0
- data/example_files/resources/hpxml-measures/.gitignore +1 -8
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.rb +1088 -1329
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.xml +1819 -1383
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/constants.rb +0 -8
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/geometry.rb +450 -362
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules.rb +165 -112
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_config.json +388 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_config.md +43 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_weekday_state_and_monthly_schedule_shift.csv +613 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_weekend_state_and_monthly_schedule_shift.csv +613 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-coal.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-appliances-dehumidifier-ief.osw → base-appliances-dehumidifier-ief-portable.osw} +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-appliances-dehumidifier-50percent.osw → base-appliances-dehumidifier-ief-whole-home.osw} +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-dehumidifier.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-modified.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-none.osw +61 -87
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-oil.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-propane.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-wood.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-flat.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-radiant-barrier.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-unvented-insulated-roof.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-vented.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-boiler-only-baseboard.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-boiler-only-fan-coil.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-mechvent-shared-preconditioning.osw → base-bldgtype-multifamily-shared-mechvent-preconditioning.osw} +70 -95
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-mechvent-shared.osw → base-bldgtype-multifamily-shared-mechvent.osw} +70 -95
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-pv.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-water-heater.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-single-family-attached.osw → base-bldgtype-single-family-attached.osw} +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-combi-tankless-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-combi-tankless.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-dwhr.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-standbyloss.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-with-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-electric.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-hpwh.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-indirect.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-low-flow-fixtures.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-none.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-demand.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-manual.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-nocontrol.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-temperature.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-timer.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-evacuated-tube.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-flat-plate.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-ics.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-indirect-flat-plate.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-thermosyphon-flat-plate.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-coal.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-elec-uef.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas-uef.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-outside.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-uef.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-with-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-with-solar.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-oil.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-wood.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric-outside.osw +56 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric-uef.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-uef.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-with-solar-fraction.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-with-solar.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-propane.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-2stories-garage.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-2stories.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-1.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-2.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-4.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-5.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-garage.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-ach-house-pressure.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-cfm-house-pressure.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-cfm50.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-flue.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-natural-ach.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-overhangs.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-windows-none.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-ambient.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-conditioned-basement-slab-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-slab.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement-assembly-r.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement-wall-insulation.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unvented-crawlspace.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-vented-crawlspace.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed-cooling-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed-heating-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-2-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-var-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-coal-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-elec-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-gas-central-ac-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-gas-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-oil-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-propane-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-wood-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-2-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-var-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-plus-air-to-air-heat-pump-heating.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-electric.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-2-speed.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-var-speed.osw +55 -81
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-mini-split-heat-pump-ducted.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ducts-leakage-percent.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-elec-resistance-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-furnace-gas.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-only-ducted.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-fireplace-wood-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-fixed-heater-gas-only.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-floor-furnace-propane-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-coal-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-elec-central-ac-1-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-elec-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-central-ac-2-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-central-ac-var-speed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-room-ac.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-oil-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-propane-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-wood-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump-cooling-only.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump-heating-only.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump.osw +56 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-airflow-defect-furnace-gas-central-ac-1-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-1-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-2-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-var-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-1-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-2-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-var-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-only.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-ground-to-air-heat-pump.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-mini-split-air-conditioner-only-ducted.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-mini-split-heat-pump-ducted.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-charge-defect-furnace-gas-central-ac-1-speed.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-none-furnace-gas-central-ac-1-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-air-conditioner-only-ducted.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-air-conditioner-only-ductless.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted-cooling-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted-heating-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ductless.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-none.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-portable-heater-gas-only.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-programmable-thermostat-detailed.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-room-ac-only-33percent.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-room-ac-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-setpoints.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-stove-oil-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-stove-wood-pellets-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-undersized.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-wall-furnace-elec-only.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-lighting-ceiling-fans.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-lighting-detailed.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-AMY-2012.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-baltimore-md.osw +64 -90
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-dallas-tx.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-duluth-mn.osw +69 -95
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-helena-mt.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-honolulu-hi.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-miami-fl.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-phoenix-az.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-portland-or.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-balanced.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-bath-kitchen-fans.osw +64 -92
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-cfis-evap-cooler-only-ducted.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-cfis.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-erv-atre-asre.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-erv.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-exhaust-rated-flow-rate.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-exhaust.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-hrv-asre.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-hrv.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-supply.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-whole-house-fan.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-defaults.osw +57 -83
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-loads-large-uncommon.osw +60 -86
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-loads-large-uncommon2.osw +60 -86
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-neighbor-shading.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-shielding-of-home.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-usage-multiplier.osw +52 -78
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-pv.osw +52 -78
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-vacancy-6-months.osw → base-schedules-stochastic-vacant.osw} +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-schedules-stochastic.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-schedules-user-specified.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-calendar-year-custom.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-daylight-saving-custom.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-daylight-saving-disabled.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-runperiod-1-month.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-timestep-10-mins.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/build_residential_hpxml_test.rb +71 -57
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-auto.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-double-exterior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-eaves.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-single-exterior-front.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-atticroof-conditioned-eaves-gable.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-atticroof-conditioned-eaves-hip.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-atticroof-flat.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-pv-shared.osw → extra-bldgtype-single-family-attached-double-exterior.osw} +62 -89
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-double-loaded-interior.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-dhw-shared-water-heater.osw → extra-bldgtype-single-family-attached-single-exterior-front.osw} +60 -86
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unconditioned-basement-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unconditioned-basement-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-multifamily.osw → extra-bldgtype-single-family-attached-unconditioned-basement.osw} +64 -91
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-dhw-solar-latitude.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-atticroof-conditioned-eaves-gable.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-atticroof-conditioned-eaves-hip.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-garage-atticroof-conditioned.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-garage-partially-protruded.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-windows-shading.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-gas-hot-tub-heater-with-zero-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-gas-pool-heater-with-zero-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-pv-roofpitch.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-schedules-random-seed.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-boiler-to-heat-pump.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-boiler-to-heating-system.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-fireplace-to-heat-pump.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-second-heating-system-fireplace.osw → extra-second-heating-system-fireplace-to-heating-system.osw} +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-portable-heater-to-heat-pump.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-second-heating-system-portable-heater.osw → extra-second-heating-system-portable-heater-to-heating-system.osw} +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-refrigerator.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-clothes-washer-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-dishwasher-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-extra-refrigerator-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-freezer-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-refrigerator-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-attic-with-floor-insulation.osw +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-attic-with-one-floor-above-grade.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-basement-with-ceiling-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/cooling-system-and-heat-pump.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/dhw-indirect-without-boiler.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/ducts-location-and-areas-not-same-type.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/foundation-wall-insulation-greater-than-height.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/heating-system-and-heat-pump.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-bottom-crawlspace-zero-foundation-height.osw +64 -89
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-bottom-slab-non-zero-foundation-height.osw +64 -89
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-no-building-orientation.osw +63 -88
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-hvac-programmable-thermostat.osw → invalid_files/multipliers-without-fuel-loads.osw} +54 -80
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-other-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-tv-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{base-dhw-uef.osw → invalid_files/multipliers-without-vehicle-plug-loads.osw} +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-well-pump-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-electric-heat-pump-water-heater.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-integer-ceiling-fan-quantity.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-integer-geometry-num-bathrooms.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-but-no-primary-heating.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-serves-majority-heat.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-serves-total-heat-load.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-attached-ambient.osw +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-attached-no-building-orientation.osw +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-detached-finished-basement-zero-foundation-height.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-detached-slab-non-zero-foundation-height.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-detached-with-shared-system.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/slab-non-zero-foundation-height-above-grade.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unconditioned-basement-with-wall-and-ceiling-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unvented-attic-with-floor-and-roof-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unvented-crawlspace-with-wall-and-ceiling-insulation.osw +59 -85
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/vented-attic-with-floor-and-roof-insulation.osw +58 -84
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/vented-crawlspace-with-wall-and-ceiling-insulation.osw +56 -82
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/zero-number-of-bedrooms.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/schedules/vacant.csv +8761 -0
- data/example_files/resources/hpxml-measures/Changelog.md +249 -0
- data/example_files/resources/hpxml-measures/Gemfile +2 -5
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.rb +404 -1357
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.xml +247 -171
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/BaseElements.xsd +11 -101
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/EPvalidator.xml +824 -301
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/HPXMLDataTypes.xsd +18 -35
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/HPXMLvalidator.xml +526 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/airflow.rb +135 -207
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constants.rb +14 -186
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constructions.rb +549 -93
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/energyplus.rb +12 -15
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/generator.rb +78 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/geometry.rb +413 -15
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hotwater_appliances.rb +48 -37
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml.rb +1627 -1227
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_defaults.rb +1192 -434
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac.rb +1555 -1616
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac_sizing.rb +1436 -1479
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/lighting.rb +3 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/location.rb +22 -10
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/meta_measure.rb +85 -19
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/minitest_helper.rb +4 -26
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/misc_loads.rb +22 -46
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/pv.rb +22 -21
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedules.rb +51 -14
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/simcontrols.rb +24 -7
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/unit_conversions.rb +2 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/validator.rb +80 -19
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/version.rb +9 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/waterheater.rb +106 -75
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/xmlhelper.rb +109 -34
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_airflow.rb +22 -36
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_defaults.rb +1565 -768
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_enclosure.rb +151 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_generator.rb +101 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb +9 -18
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac.rb +316 -28
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac_sizing.rb +53 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_lighting.rb +4 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_location.rb +13 -11
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_miscloads.rb +4 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_pv.rb +5 -3
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_simcontrols.rb +13 -11
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_validation.rb +102 -62
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_water_heater.rb +189 -35
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/util.rb +26 -0
- data/example_files/resources/hpxml-measures/README.md +5 -5
- data/example_files/resources/hpxml-measures/Rakefile +2 -10
- data/example_files/resources/hpxml-measures/SimulationOutputReport/measure.rb +416 -299
- data/example_files/resources/hpxml-measures/SimulationOutputReport/measure.xml +364 -481
- data/example_files/resources/hpxml-measures/SimulationOutputReport/resources/constants.rb +1 -2
- data/example_files/resources/hpxml-measures/SimulationOutputReport/tests/output_report_test.rb +327 -320
- data/example_files/resources/hpxml-measures/docs/source/build_residential_hpxml.rst +3 -3
- data/example_files/resources/hpxml-measures/docs/source/conf.py +11 -5
- data/example_files/resources/hpxml-measures/docs/source/getting_started.rst +6 -6
- data/example_files/resources/hpxml-measures/docs/source/index.rst +2 -2
- data/example_files/resources/hpxml-measures/docs/source/intro.rst +7 -109
- data/example_files/resources/hpxml-measures/docs/source/nstatic/stylesheet.css +13 -1
- data/example_files/resources/hpxml-measures/docs/source/workflow_inputs.rst +2482 -0
- data/example_files/resources/hpxml-measures/docs/source/workflow_outputs.rst +282 -0
- data/example_files/resources/hpxml-measures/tasks.rb +2494 -1248
- data/example_files/resources/hpxml-measures/weather/USA_AZ_Phoenix-Sky.Harbor.Intl.AP.722780_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_AZ_Phoenix-Sky.Harbor.Intl.AP.722780_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_CO_Denver.Intl.AP.725650_TMY3-cache.csv +10 -10
- data/example_files/resources/hpxml-measures/weather/USA_HI_Honolulu.Intl.AP.911820_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_HI_Honolulu.Intl.AP.911820_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_MT_Helena.Rgnl.AP.727720_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_MT_Helena.Rgnl.AP.727720_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_OR_Portland.Intl.AP.726980_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_OR_Portland.Intl.AP.726980_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/workflow/run_simulation.rb +96 -21
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-coal.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-appliances-dehumidifier-ief.xml → base-appliances-dehumidifier-ief-portable.xml} +8 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-appliances-dehumidifier-50percent.xml → base-appliances-dehumidifier-ief-whole-home.xml} +10 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-multiple.xml +535 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier.xml +525 -524
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-gas.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-modified.xml +564 -565
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-none.xml +513 -513
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-oil.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-propane.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-wood.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-cathedral.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-conditioned.xml +633 -634
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-flat.xml +531 -532
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-radiant-barrier.xml +517 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-unvented-insulated-roof.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-vented.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-multifamily-buffer-space.xml → base-bldgtype-multifamily-adjacent-to-multifamily-buffer-space.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-multiple.xml +554 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-non-freezing-space.xml → base-bldgtype-multifamily-adjacent-to-non-freezing-space.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-heated-space.xml → base-bldgtype-multifamily-adjacent-to-other-heated-space.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-other-housing-unit.xml → base-bldgtype-multifamily-adjacent-to-other-housing-unit.xml} +34 -62
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-baseboard.xml +425 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-fan-coil-ducted.xml +457 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-fan-coil.xml +427 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-water-loop-heat-pump.xml +479 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-cooling-tower-water-loop-heat-pump.xml +474 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-baseboard.xml +408 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil-ducted.xml +439 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil-eae.xml +406 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil.xml +409 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-water-loop-heat-pump.xml +457 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-baseboard.xml +407 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-fan-coil-ducted.xml +438 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-fan-coil.xml +408 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-water-loop-heat-pump.xml +456 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-cooling-tower-only-water-loop-heat-pump.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-generator.xml +460 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-ground-loop-ground-to-air-heat-pump.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-laundry-room.xml +466 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-mechvent-shared-multiple.xml → base-bldgtype-multifamily-shared-mechvent-multiple.xml} +43 -415
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent-preconditioning.xml +489 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent.xml +473 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-pv.xml +465 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-water-heater-recirc.xml +458 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-water-heater.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily.xml +448 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-single-family-attached.xml +619 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless-outside.xml +516 -519
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless.xml +516 -519
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-2-speed.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-gshp.xml +7 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-hpwh.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-tankless.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-var-speed.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-dwhr.xml +567 -568
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-dse.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-outside.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-standbyloss.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-with-solar-fraction.xml +525 -528
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-electric.xml +567 -568
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-gas.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-hpwh.xml +566 -567
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-indirect.xml +522 -525
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-low-flow-fixtures.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-multiple.xml +575 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-none.xml +497 -497
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-demand.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-manual.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-nocontrol.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-temperature.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-timer.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-evacuated-tube.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-flat-plate.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-ics.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-fraction.xml +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-indirect-flat-plate.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-thermosyphon-flat-plate.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-coal.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-elec-uef.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-outside.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-uef.xml +565 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-outside.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-uef.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar-fraction.xml +569 -570
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-oil.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-wood.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-outside.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-uef.xml +561 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-uef.xml +561 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar-fraction.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-propane.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories-garage.xml +661 -664
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-1.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-2.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-4.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-5.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-garage.xml +636 -639
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-ach-house-pressure.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm-house-pressure.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm50.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-flue.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-natural-ach.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-overhangs.xml +582 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-rooftypes.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-shading.xml +601 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-level.xml +517 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-surfaces.xml +2474 -2493
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-surfaces2.xml +2475 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-walltypes.xml +754 -755
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-none.xml +504 -505
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-windows-interior-shading.xml → base-enclosure-windows-shading.xml} +23 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-ambient.xml +498 -497
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-basement-garage.xml +644 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-complex.xml +724 -729
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-slab-insulation.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-wall-interior-insulation.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-multiple.xml +685 -688
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-slab.xml +516 -517
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-above-grade.xml +609 -610
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-assembly-r.xml +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-wall-insulation.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unvented-crawlspace.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-vented-crawlspace.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-walkout-basement.xml +627 -628
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-autosize.xml → base-hvac-air-to-air-heat-pump-1-speed-cooling-only.xml} +8 -12
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-1-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-air-to-air-heat-pump-1-speed-heating-only.xml} +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-2-speed.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-cooling-only.xml +553 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-1-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-1-speed-heating-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-manual-s-oversize-allowances.xml +561 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed.xml +558 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-2-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-air-to-air-heat-pump-2-speed-manual-s-oversize-allowances.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-2-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-2-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-var-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-air-to-air-heat-pump-var-speed-manual-s-oversize-allowances.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-var-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-var-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-elec-only-autosize.xml → base-hvac-autosize-boiler-elec-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-gas-central-ac-1-speed-autosize.xml → base-hvac-autosize-boiler-gas-central-ac-1-speed.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-gas-only-autosize.xml → base-hvac-autosize-boiler-gas-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-1-speed-autosize.xml → base-hvac-autosize-central-ac-only-1-speed.xml} +547 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-2-speed-autosize.xml → base-hvac-autosize-central-ac-only-2-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-var-speed-autosize.xml → base-hvac-autosize-central-ac-only-var-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-plus-air-to-air-heat-pump-heating-autosize.xml → base-hvac-autosize-central-ac-plus-air-to-air-heat-pump-heating.xml} +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed.xml +559 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-dual-fuel-mini-split-heat-pump-ducted-autosize.xml → base-hvac-autosize-dual-fuel-mini-split-heat-pump-ducted.xml} +557 -558
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-elec-resistance-only-autosize.xml → base-hvac-autosize-elec-resistance-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-evap-cooler-furnace-gas-autosize.xml → base-hvac-autosize-evap-cooler-furnace-gas.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-floor-furnace-propane-only-autosize.xml → base-hvac-autosize-floor-furnace-propane-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-elec-only-autosize.xml → base-hvac-autosize-furnace-elec-only.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-central-ac-2-speed-autosize.xml → base-hvac-autosize-furnace-gas-central-ac-2-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-central-ac-var-speed-autosize.xml → base-hvac-autosize-furnace-gas-central-ac-var-speed.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-only-autosize.xml → base-hvac-autosize-furnace-gas-only.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-room-ac-autosize.xml → base-hvac-autosize-furnace-gas-room-ac.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-cooling-only.xml +555 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-heating-only.xml +560 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-ground-to-air-heat-pump-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-ground-to-air-heat-pump-manual-s-oversize-allowances.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-ground-to-air-heat-pump-autosize.xml → base-hvac-autosize-ground-to-air-heat-pump.xml} +4 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-air-conditioner-only-ducted.xml +547 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-cooling-only-autosize.xml → base-hvac-autosize-mini-split-heat-pump-ducted-cooling-only.xml} +551 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-heating-only-autosize.xml → base-hvac-autosize-mini-split-heat-pump-ducted-heating-only.xml} +556 -557
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-manual-s-oversize-allowances.xml +560 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-autosize.xml → base-hvac-autosize-mini-split-heat-pump-ducted.xml} +556 -557
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-room-ac-only-autosize.xml → base-hvac-autosize-room-ac-only.xml} +2 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-stove-oil-only-autosize.xml → base-hvac-autosize-stove-oil-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-wall-furnace-elec-only-autosize.xml → base-hvac-autosize-wall-furnace-elec-only.xml} +5 -6
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-autosize.xml → base-hvac-autosize.xml} +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-coal-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-elec-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-central-ac-1-speed.xml +571 -573
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-only.xml +519 -522
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-oil-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-propane-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-wood-only.xml +518 -521
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-1-speed.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-2-speed.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-var-speed.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-plus-air-to-air-heat-pump-heating.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dse.xml +532 -535
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-electric.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-2-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-var-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-mini-split-heat-pump-ducted.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-leakage-percent.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-elec-resistance-only.xml +509 -512
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-furnace-gas.xml +555 -555
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only-ducted.xml +536 -528
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only.xml +503 -505
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fireplace-wood-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fixed-heater-gas-only.xml +6 -57
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-floor-furnace-propane-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-coal-only.xml +549 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-central-ac-1-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-2-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-var-speed.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only.xml +5 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-room-ac.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-oil-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-propane-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-wood-only.xml +548 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-x3-dse.xml +576 -579
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-cooling-only.xml +557 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-heating-only.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump.xml +7 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-flowrate.xml → base-hvac-install-quality-airflow-defect-furnace-gas-central-ac-1-speed.xml} +8 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{invalid_files/heat-pump-mixed-fixed-and-autosize-capacities2.xml → base-hvac-install-quality-all-air-to-air-heat-pump-1-speed.xml} +13 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-air-to-air-heat-pump-2-speed.xml +567 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-air-to-air-heat-pump-var-speed.xml +567 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-central-ac-1-speed.xml +572 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-central-ac-2-speed.xml +572 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-central-ac-var-speed.xml +572 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-only.xml +553 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-ground-to-air-heat-pump.xml +566 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-air-conditioner-only-ducted-autosize.xml → base-hvac-install-quality-all-mini-split-air-conditioner-only-ducted.xml} +10 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-autosize-manual-s-oversize-allowances.xml → base-hvac-install-quality-all-mini-split-heat-pump-ducted.xml} +13 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-blower-efficiency-furnace-gas-central-ac-1-speed.xml +569 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-misc-shelter-coefficient.xml → base-hvac-install-quality-charge-defect-furnace-gas-central-ac-1-speed.xml} +9 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-none-furnace-gas-central-ac-1-speed.xml +570 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ducted.xml +547 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ductless.xml +508 -511
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-cooling-only.xml +554 -555
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-heating-only.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless.xml +515 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-multiple.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-none.xml +486 -489
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-portable-heater-gas-only.xml +6 -57
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-programmable-thermostat-detailed.xml +567 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-programmable-thermostat.xml +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-33percent.xml +508 -511
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only.xml +508 -511
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-oil-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-wood-pellets-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized-allow-increased-fixed-capacities.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-wall-furnace-elec-only.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-ceiling-fans.xml +573 -574
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-detailed.xml +585 -586
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-none.xml +488 -489
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-AMY-2012.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-baltimore-md.xml +573 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-dallas-tx.xml +516 -517
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-duluth-mn.xml +573 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-helena-mt.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-honolulu-hi.xml +517 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-miami-fl.xml +516 -517
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-phoenix-az.xml +517 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-portland-or.xml +577 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-balanced.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-bath-kitchen-fans.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-dse.xml +545 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-evap-cooler-only-ducted.xml +549 -541
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv-atre-asre.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv.xml +576 -577
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust-rated-flow-rate.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv-asre.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-multiple.xml +796 -795
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-supply.xml +574 -575
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-whole-house-fan.xml +572 -573
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-defaults.xml +478 -495
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators.xml +579 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon.xml +758 -833
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon2.xml +749 -820
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-none.xml +550 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-neighbor-shading.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/{invalid_files/invalid-calendar-year.xml → base-misc-shielding-of-home.xml} +7 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-usage-multiplier.xml +728 -725
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-multiple-buildings.xml +1657 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-stochastic-vacant.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-stochastic.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-user-specified.xml +6 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-calendar-year-custom.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-custom.xml +569 -570
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-disabled.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-runperiod-1-month.xml +566 -567
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/boiler-invalid-afue.xml +519 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/cfis-with-hydronic-distribution.xml +532 -535
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/clothes-dryer-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/clothes-washer-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/cooking-range-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dehumidifier-fraction-served.xml +535 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dehumidifier-setpoints.xml +535 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dhw-frac-load-served.xml +575 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-dhw-uef.xml → invalid_files/dhw-invalid-ef-tank.xml} +7 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dhw-invalid-uef-tank-heat-pump.xml +564 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dishwasher-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-leakage-cfm25.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-leakage-percent.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-location-unconditioned-space.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duplicate-id.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-attic-missing-roof.xml +546 -547
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-basement-missing-exterior-foundation-wall.xml +543 -544
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-basement-missing-slab.xml +546 -545
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-floor-area-exceeds-cfa.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-floor-area-exceeds-cfa2.xml +448 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-exterior-wall.xml +613 -616
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-roof-ceiling.xml +626 -629
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-slab.xml +610 -611
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-ceiling-roof.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-exterior-wall.xml +472 -473
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-floor-slab.xml +488 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-sensible-fuel-load.xml +760 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-sensible-plug-load.xml +759 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-total-fuel-load.xml +761 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-total-plug-load.xml +759 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/furnace-invalid-afue.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/generator-number-of-bedrooms-served.xml +460 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/generator-output-greater-than-consumption.xml +579 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/heat-pump-mixed-fixed-and-autosize-capacities.xml +559 -560
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-multiple-attached-cooling.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-multiple-attached-heating.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-return-duct-leakage-missing.xml +528 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-dse-multiple-attached-cooling.xml +546 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-dse-multiple-attached-heating.xml +546 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-frac-load-served.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-inconsistent-fan-powers.xml +569 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-invalid-distribution-system-type.xml +570 -571
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-shared-negative-seer-eq.xml +407 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-assembly-effective-rvalue.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-boolean.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-float.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-integer.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-daylight-saving.xml +569 -567
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-distribution-cfa-served.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-epw-filepath.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-facility-type-equipment.xml +466 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-facility-type-surfaces.xml +644 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/{appliances-location-unconditioned-space.xml → invalid-foundation-wall-properties.xml} +39 -29
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-id.xml +591 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-id2.xml +591 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-infiltration-volume.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-input-parameters.xml +565 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-neighbor-shading-azimuth.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-number-of-bedrooms-served.xml +465 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/{slab-zero-exposed-perimeter.xml → invalid-number-of-conditioned-floors.xml} +7 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-number-of-units-served.xml +451 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-relatedhvac-desuperheater.xml +550 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-relatedhvac-dhw-indirect.xml +517 -520
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-runperiod.xml +564 -565
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-schema-version.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-shared-vent-in-unit-flowrate.xml +473 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-timestep.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-window-height.xml +582 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/lighting-fractions.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/missing-duct-location.xml +21 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/missing-elements.xml +560 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-appliance.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-duct.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-surface.xml +575 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-water-heater.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-buildings-without-building-id.xml +1657 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-buildings-wrong-building-id.xml +1657 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-shared-cooling-systems.xml +432 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-shared-heating-systems.xml +434 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/net-area-negative-roof.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/net-area-negative-wall.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/num-bedrooms-exceeds-limit.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/orphaned-hvac-distribution.xml +546 -547
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerator-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerators-multiple-primary.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerators-no-primary.xml +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/repeated-relatedhvac-desuperheater.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/repeated-relatedhvac-dhw-indirect.xml +526 -529
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-fraction-one.xml +571 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-combi-tankless.xml +531 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-desuperheater.xml +565 -566
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-dhw-indirect.xml +531 -534
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-cfis.xml +575 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-door.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-hvac-distribution.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-shared-clothes-washer-water-heater.xml +465 -827
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-shared-dishwasher-water-heater.xml +465 -827
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-skylight.xml +590 -591
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-solar-thermal-system.xml +577 -578
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-window.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/water-heater-location-other.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/water-heater-location.xml +562 -563
- data/example_files/resources/hpxml-measures/workflow/template.osw +5 -1
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AC.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AL.xml +6 -17
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L302XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L304XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L322XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L324XC.xml +6 -19
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results.csv +294 -0
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_ashrae_140.csv +27 -0
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_hvac_sizing.csv +294 -0
- data/example_files/resources/hpxml-measures/workflow/tests/compare.rb +130 -0
- data/example_files/resources/hpxml-measures/workflow/tests/hpxml_translator_test.rb +522 -527
- data/example_files/{measures/BuildResidentialModel/resources → resources}/measure-info.json +0 -0
- data/example_files/{measures/BuildResidentialModel/resources → resources}/meta_measure.rb +53 -44
- data/example_files/validation_schema.yaml +149 -0
- data/example_files/visualization/input_visualization_feature.html +213 -56
- data/example_files/visualization/input_visualization_scenario.html +92 -30
- data/lib/uo_cli.rb +406 -128
- data/lib/uo_cli/version.rb +17 -7
- data/requirements.txt +2 -0
- data/scripts/setup-env-gitbash.sh +5 -5
- data/scripts/setup-env-unix.sh +4 -4
- data/scripts/setup-env.bat +14 -11
- data/scripts/setup-env.ps1 +13 -10
- data/uo_cli.gemspec +10 -8
- metadata +390 -130
- data/developer_nrel_key.rb +0 -31
- data/example_files/measures/ResidentialGeometryCreateMultifamily/measure.rb +0 -1005
- data/example_files/measures/ResidentialGeometryCreateMultifamily/measure.xml +0 -326
- data/example_files/measures/ResidentialGeometryCreateMultifamily/tests/create_residential_multifamily_geometry_test.rb +0 -477
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/measure.rb +0 -1039
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/measure.xml +0 -393
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/tests/create_residential_single_family_attached_geometry_test.rb +0 -456
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/measure.rb +0 -979
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/measure.xml +0 -388
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/tests/create_residential_single_family_detached_geometry_test.rb +0 -704
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/location.rb +0 -24
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_config.yml +0 -61
- data/example_files/resources/hpxml-measures/docs/source/hpxml_to_openstudio.rst +0 -1386
- data/example_files/resources/hpxml-measures/docs/source/simulation_output_report.rst +0 -252
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-shared-laundry-room.xml +0 -828
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-shared-water-heater-recirc.xml +0 -820
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-shared-water-heater.xml +0 -813
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-attached-multifamily.xml +0 -810
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-common-surfaces.xml +0 -928
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ideal-air.xml +0 -501
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-multiple2.xml +0 -838
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-baseboard.xml +0 -777
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-fan-coil-ducted.xml +0 -808
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-fan-coil.xml +0 -780
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-chiller-water-loop-heat-pump.xml +0 -820
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-cooling-tower-water-loop-heat-pump.xml +0 -815
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-baseboard.xml +0 -760
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-fan-coil-ducted.xml +0 -790
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-fan-coil-eae.xml +0 -759
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-fan-coil.xml +0 -762
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-boiler-only-water-loop-heat-pump.xml +0 -796
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-baseboard.xml +0 -759
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-fan-coil-ducted.xml +0 -789
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-fan-coil.xml +0 -761
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-chiller-only-water-loop-heat-pump.xml +0 -796
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-cooling-tower-only-water-loop-heat-pump.xml +0 -791
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-shared-ground-loop-ground-to-air-heat-pump.xml +0 -814
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-shared-preconditioning.xml +0 -851
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-shared.xml +0 -835
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-shared.xml +0 -827
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/coal-for-non-boiler-heating.xml +0 -514
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-facility-type.xml +0 -828
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-window-interior-shading.xml +0 -564
@@ -1,25 +1,23 @@
|
|
1
1
|
# frozen_string_literal: true
|
2
2
|
|
3
3
|
class Airflow
|
4
|
-
def self.apply(model, runner, weather, spaces,
|
5
|
-
duct_systems,
|
6
|
-
|
7
|
-
site_type, shelter_coef, has_flue_chimney, hvac_map, eri_version,
|
8
|
-
apply_ashrae140_assumptions, schedules_file)
|
4
|
+
def self.apply(model, runner, weather, spaces, hpxml, cfa, nbeds,
|
5
|
+
ncfl_ag, duct_systems, nv_clg_ssn_sensor, hvac_map, eri_version,
|
6
|
+
frac_windows_operable, apply_ashrae140_assumptions, schedules_file)
|
9
7
|
|
10
8
|
# Global variables
|
11
9
|
|
12
10
|
@runner = runner
|
13
11
|
@spaces = spaces
|
14
|
-
@
|
15
|
-
@
|
16
|
-
@infil_height = infil_height
|
12
|
+
@infil_volume = hpxml.air_infiltration_measurements.select { |i| !i.infiltration_volume.nil? }[0].infiltration_volume
|
13
|
+
@infil_height = hpxml.inferred_infiltration_height(@infil_volume)
|
17
14
|
@living_space = spaces[HPXML::LocationLivingSpace]
|
18
15
|
@living_zone = @living_space.thermalZone.get
|
19
16
|
@nbeds = nbeds
|
17
|
+
@ncfl_ag = ncfl_ag
|
20
18
|
@eri_version = eri_version
|
21
19
|
@apply_ashrae140_assumptions = apply_ashrae140_assumptions
|
22
|
-
@cfa =
|
20
|
+
@cfa = cfa
|
23
21
|
|
24
22
|
# Global sensors
|
25
23
|
|
@@ -57,7 +55,7 @@ class Airflow
|
|
57
55
|
vent_fans_kitchen = []
|
58
56
|
vent_fans_bath = []
|
59
57
|
vent_fans_whf = []
|
60
|
-
|
58
|
+
hpxml.ventilation_fans.each do |vent_fan|
|
61
59
|
if vent_fan.used_for_whole_building_ventilation
|
62
60
|
vent_fans_mech << vent_fan
|
63
61
|
elsif vent_fan.used_for_seasonal_cooling_load_reduction
|
@@ -71,6 +69,9 @@ class Airflow
|
|
71
69
|
end
|
72
70
|
end
|
73
71
|
|
72
|
+
# Vented clothes dryers in conditioned space
|
73
|
+
vented_dryers = hpxml.clothes_dryers.select { |cd| cd.is_vented && cd.vented_flow_rate.to_f > 0 && [HPXML::LocationLivingSpace, HPXML::LocationBasementConditioned].include?(cd.location) }
|
74
|
+
|
74
75
|
# Initialization
|
75
76
|
initialize_cfis(model, vent_fans_mech, hvac_map)
|
76
77
|
model.getAirLoopHVACs.each do |air_loop|
|
@@ -88,14 +89,27 @@ class Airflow
|
|
88
89
|
|
89
90
|
# Apply infiltration/ventilation
|
90
91
|
|
91
|
-
|
92
|
-
|
93
|
-
|
94
|
-
|
95
|
-
|
92
|
+
set_wind_speed_correction(model, hpxml.site)
|
93
|
+
window_area = hpxml.windows.map { |w| w.area }.sum(0.0)
|
94
|
+
open_window_area = window_area * frac_windows_operable * 0.5 * 0.2 # Assume A) 50% of the area of an operable window can be open, and B) 20% of openable window area is actually open
|
95
|
+
|
96
|
+
vented_attic = nil
|
97
|
+
hpxml.attics.each do |attic|
|
98
|
+
next unless attic.attic_type == HPXML::AtticTypeVented
|
96
99
|
|
97
|
-
|
98
|
-
|
100
|
+
vented_attic = attic
|
101
|
+
end
|
102
|
+
vented_crawl = nil
|
103
|
+
hpxml.foundations.each do |foundation|
|
104
|
+
next unless foundation.foundation_type == HPXML::FoundationTypeCrawlspaceVented
|
105
|
+
|
106
|
+
vented_crawl = foundation
|
107
|
+
end
|
108
|
+
|
109
|
+
apply_natural_ventilation_and_whole_house_fan(model, weather, hpxml.site, vent_fans_whf, open_window_area, nv_clg_ssn_sensor)
|
110
|
+
apply_infiltration_and_ventilation_fans(model, weather, hpxml.site, vent_fans_mech, vent_fans_kitchen, vent_fans_bath, vented_dryers,
|
111
|
+
hpxml.building_construction.has_flue_or_chimney, hpxml.air_infiltration_measurements,
|
112
|
+
vented_attic, vented_crawl, hvac_map, schedules_file)
|
99
113
|
end
|
100
114
|
|
101
115
|
def self.get_default_fraction_of_windows_operable()
|
@@ -107,11 +121,11 @@ class Airflow
|
|
107
121
|
end
|
108
122
|
|
109
123
|
def self.get_default_vented_attic_sla()
|
110
|
-
return 1.0 / 300.0 # Table 4.2.2(1) - Attics
|
124
|
+
return (1.0 / 300.0).round(6) # Table 4.2.2(1) - Attics
|
111
125
|
end
|
112
126
|
|
113
127
|
def self.get_default_vented_crawl_sla()
|
114
|
-
return 1.0 / 150.0 # Table 4.2.2(1) - Crawlspaces
|
128
|
+
return (1.0 / 150.0).round(6) # Table 4.2.2(1) - Crawlspaces
|
115
129
|
end
|
116
130
|
|
117
131
|
def self.get_default_mech_vent_fan_power(vent_fan)
|
@@ -134,60 +148,53 @@ class Airflow
|
|
134
148
|
|
135
149
|
private
|
136
150
|
|
137
|
-
def self.set_wind_speed_correction(model,
|
151
|
+
def self.set_wind_speed_correction(model, site)
|
152
|
+
site_ap = site.additional_properties
|
153
|
+
|
138
154
|
site_map = { HPXML::SiteTypeRural => 'Country', # Flat, open country
|
139
155
|
HPXML::SiteTypeSuburban => 'Suburbs', # Rough, wooded country, suburbs
|
140
156
|
HPXML::SiteTypeUrban => 'City' } # Towns, city outskirts, center of large cities
|
141
|
-
model.getSite.setTerrain(site_map[site_type])
|
157
|
+
model.getSite.setTerrain(site_map[site.site_type])
|
142
158
|
|
143
|
-
|
144
|
-
wind_speed.height = 32.8 # ft (Standard weather station height)
|
159
|
+
site_ap.height = 32.8 # ft (Standard weather station height)
|
145
160
|
|
146
161
|
# Open, Unrestricted at Weather Station
|
147
|
-
|
148
|
-
|
149
|
-
|
150
|
-
|
151
|
-
|
152
|
-
if site_type == HPXML::SiteTypeRural
|
153
|
-
|
154
|
-
|
155
|
-
|
156
|
-
|
157
|
-
elsif site_type == HPXML::SiteTypeSuburban
|
158
|
-
|
159
|
-
|
160
|
-
|
161
|
-
|
162
|
-
elsif site_type == HPXML::SiteTypeUrban
|
163
|
-
|
164
|
-
|
165
|
-
|
166
|
-
|
167
|
-
end
|
168
|
-
|
169
|
-
# Local Shielding
|
170
|
-
if shelter_coef.nil?
|
171
|
-
# FIXME: Move into HPXML defaults
|
172
|
-
if min_neighbor_distance.nil?
|
173
|
-
# Typical shelter for isolated rural house
|
174
|
-
wind_speed.S_wo = 0.90
|
175
|
-
elsif min_neighbor_distance > @building_height
|
176
|
-
# Typical shelter caused by other building across the street
|
177
|
-
wind_speed.S_wo = 0.70
|
178
|
-
else
|
179
|
-
# Typical shelter for urban buildings where sheltering obstacles
|
180
|
-
# are less than one building height away.
|
181
|
-
wind_speed.S_wo = 0.50
|
182
|
-
end
|
183
|
-
else
|
184
|
-
wind_speed.S_wo = Float(shelter_coef)
|
162
|
+
site_ap.terrain_multiplier = 1.0
|
163
|
+
site_ap.terrain_exponent = 0.15
|
164
|
+
site_ap.ashrae_terrain_thickness = 270
|
165
|
+
site_ap.ashrae_terrain_exponent = 0.14
|
166
|
+
|
167
|
+
if site.site_type == HPXML::SiteTypeRural
|
168
|
+
site_ap.site_terrain_multiplier = 0.85
|
169
|
+
site_ap.site_terrain_exponent = 0.20
|
170
|
+
site_ap.ashrae_site_terrain_thickness = 270 # Flat, open country
|
171
|
+
site_ap.ashrae_site_terrain_exponent = 0.14 # Flat, open country
|
172
|
+
elsif site.site_type == HPXML::SiteTypeSuburban
|
173
|
+
site_ap.site_terrain_multiplier = 0.67
|
174
|
+
site_ap.site_terrain_exponent = 0.25
|
175
|
+
site_ap.ashrae_site_terrain_thickness = 370 # Rough, wooded country, suburbs
|
176
|
+
site_ap.ashrae_site_terrain_exponent = 0.22 # Rough, wooded country, suburbs
|
177
|
+
elsif site.site_type == HPXML::SiteTypeUrban
|
178
|
+
site_ap.site_terrain_multiplier = 0.47
|
179
|
+
site_ap.site_terrain_exponent = 0.35
|
180
|
+
site_ap.ashrae_site_terrain_thickness = 460 # Towns, city outskirts, center of large cities
|
181
|
+
site_ap.ashrae_site_terrain_exponent = 0.33 # Towns, city outskirts, center of large cities
|
185
182
|
end
|
186
183
|
|
187
184
|
# S-G Shielding Coefficients are roughly 1/3 of AIM2 Shelter Coefficients
|
188
|
-
|
185
|
+
site_ap.s_g_shielding_coef = site_ap.aim2_shelter_coeff / 3.0
|
186
|
+
end
|
189
187
|
|
190
|
-
|
188
|
+
def self.get_aim2_shelter_coefficient(shielding_of_home)
|
189
|
+
# Mapping based on AIM-2 Model by Walker/Wilson
|
190
|
+
# Table 2: Estimates of Shelter Coefficient S_wo for No Flue
|
191
|
+
if shielding_of_home == HPXML::ShieldingNormal
|
192
|
+
return 0.50 # Class 4: "Very heavy shielding, many large obstructions within one house height"
|
193
|
+
elsif shielding_of_home == HPXML::ShieldingExposed
|
194
|
+
return 0.90 # Class 2: "Light local shielding with few obstructions within two house heights"
|
195
|
+
elsif shielding_of_home == HPXML::ShieldingWellShielded
|
196
|
+
return 0.30 # Class 5: "Complete shielding, with large buildings immediately adjacent"
|
197
|
+
end
|
191
198
|
end
|
192
199
|
|
193
200
|
def self.apply_infiltration_to_unconditioned_space(model, space, ach = nil, ela = nil, c_w_SG = nil, c_s_SG = nil)
|
@@ -215,7 +222,7 @@ class Airflow
|
|
215
222
|
end
|
216
223
|
end
|
217
224
|
|
218
|
-
def self.apply_natural_ventilation_and_whole_house_fan(model, weather, vent_fans_whf, open_window_area, nv_clg_ssn_sensor)
|
225
|
+
def self.apply_natural_ventilation_and_whole_house_fan(model, weather, site, vent_fans_whf, open_window_area, nv_clg_ssn_sensor)
|
219
226
|
if @living_zone.thermostatSetpointDualSetpoint.is_initialized
|
220
227
|
thermostat = @living_zone.thermostatSetpointDualSetpoint.get
|
221
228
|
htg_sch = thermostat.heatingSetpointTemperatureSchedule.get
|
@@ -262,14 +269,14 @@ class Airflow
|
|
262
269
|
nv_flow.setName(Constants.ObjectNameNaturalVentilation + ' flow')
|
263
270
|
nv_flow.setSchedule(model.alwaysOnDiscreteSchedule)
|
264
271
|
nv_flow.setSpace(@living_space)
|
265
|
-
nv_flow_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(nv_flow,
|
272
|
+
nv_flow_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(nv_flow, *EPlus::EMSActuatorZoneInfiltrationFlowRate)
|
266
273
|
nv_flow_actuator.setName("#{nv_flow.name} act")
|
267
274
|
|
268
275
|
whf_flow = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
|
269
276
|
whf_flow.setName(Constants.ObjectNameWholeHouseFan + ' flow')
|
270
277
|
whf_flow.setSchedule(model.alwaysOnDiscreteSchedule)
|
271
278
|
whf_flow.setSpace(@living_space)
|
272
|
-
whf_flow_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(whf_flow,
|
279
|
+
whf_flow_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(whf_flow, *EPlus::EMSActuatorZoneInfiltrationFlowRate)
|
273
280
|
whf_flow_actuator.setName("#{whf_flow.name} act")
|
274
281
|
|
275
282
|
# Electric Equipment (for whole house fan electricity consumption)
|
@@ -283,7 +290,7 @@ class Airflow
|
|
283
290
|
whf_equip_def.setFractionLost(1)
|
284
291
|
whf_equip.setSchedule(model.alwaysOnDiscreteSchedule)
|
285
292
|
whf_equip.setEndUseSubcategory(Constants.ObjectNameWholeHouseFan)
|
286
|
-
whf_elec_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(whf_equip,
|
293
|
+
whf_elec_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(whf_equip, *EPlus::EMSActuatorElectricEquipmentPower)
|
287
294
|
whf_elec_actuator.setName("#{whf_equip.name} act")
|
288
295
|
|
289
296
|
# Assume located in attic floor if attic zone exists; otherwise assume it's through roof/wall.
|
@@ -298,7 +305,7 @@ class Airflow
|
|
298
305
|
zone_mixing = OpenStudio::Model::ZoneMixing.new(whf_zone)
|
299
306
|
zone_mixing.setName("#{Constants.ObjectNameWholeHouseFan} mix")
|
300
307
|
zone_mixing.setSourceZone(@living_zone)
|
301
|
-
liv_to_zone_flow_rate_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(zone_mixing,
|
308
|
+
liv_to_zone_flow_rate_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(zone_mixing, *EPlus::EMSActuatorZoneMixingFlowRate)
|
302
309
|
liv_to_zone_flow_rate_actuator.setName("#{zone_mixing.name} act")
|
303
310
|
end
|
304
311
|
|
@@ -307,7 +314,7 @@ class Airflow
|
|
307
314
|
max_flow_rate = max_rate * @infil_volume / UnitConversions.convert(1.0, 'hr', 'min')
|
308
315
|
neutral_level = 0.5
|
309
316
|
hor_lk_frac = 0.0
|
310
|
-
c_w, c_s = calc_wind_stack_coeffs(hor_lk_frac, neutral_level, @living_space, @infil_height)
|
317
|
+
c_w, c_s = calc_wind_stack_coeffs(site, hor_lk_frac, neutral_level, @living_space, @infil_height)
|
311
318
|
max_oa_hr = 0.0115 # From BA HSP
|
312
319
|
max_oa_rh = 0.7 # From BA HSP
|
313
320
|
|
@@ -431,7 +438,7 @@ class Airflow
|
|
431
438
|
if hpxml_fuel_type.nil?
|
432
439
|
other_equip.setFuelType('None')
|
433
440
|
else
|
434
|
-
other_equip.setFuelType(EPlus.
|
441
|
+
other_equip.setFuelType(EPlus.fuel_type(hpxml_fuel_type))
|
435
442
|
end
|
436
443
|
if not end_use.nil?
|
437
444
|
other_equip.setEndUseSubcategory(end_use)
|
@@ -441,7 +448,7 @@ class Airflow
|
|
441
448
|
other_equip_def.setFractionLost(frac_lost)
|
442
449
|
other_equip_def.setFractionLatent(frac_lat)
|
443
450
|
other_equip_def.setFractionRadiant(0.0)
|
444
|
-
actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(other_equip,
|
451
|
+
actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(other_equip, *EPlus::EMSActuatorOtherEquipmentPower)
|
445
452
|
actuator.setName("#{other_equip.name} act")
|
446
453
|
if not is_duct_load_for_report.nil?
|
447
454
|
other_equip.additionalProperties.setFeature(Constants.IsDuctLoadForReport, is_duct_load_for_report)
|
@@ -516,7 +523,7 @@ class Airflow
|
|
516
523
|
@fan_rtf_var[air_loop] = OpenStudio::Model::EnergyManagementSystemGlobalVariable.new(model, "#{air_loop.name} Fan RTF".gsub(' ', '_'))
|
517
524
|
|
518
525
|
# Supply fan maximum mass flow rate
|
519
|
-
@fan_mfr_max_var[air_loop] = OpenStudio::Model::EnergyManagementSystemInternalVariable.new(model,
|
526
|
+
@fan_mfr_max_var[air_loop] = OpenStudio::Model::EnergyManagementSystemInternalVariable.new(model, EPlus::EMSIntVarFanMFR)
|
520
527
|
@fan_mfr_max_var[air_loop].setName("#{air_loop.name} max sup fan mfr")
|
521
528
|
@fan_mfr_max_var[air_loop].setInternalDataIndexKeyName(supply_fan.name.to_s)
|
522
529
|
|
@@ -546,7 +553,7 @@ class Airflow
|
|
546
553
|
@fan_rtf_var[fan_coil] = OpenStudio::Model::EnergyManagementSystemGlobalVariable.new(model, "#{fan_coil.name} Fan RTF".gsub(' ', '_'))
|
547
554
|
|
548
555
|
# Supply fan maximum mass flow rate
|
549
|
-
@fan_mfr_max_var[fan_coil] = OpenStudio::Model::EnergyManagementSystemInternalVariable.new(model,
|
556
|
+
@fan_mfr_max_var[fan_coil] = OpenStudio::Model::EnergyManagementSystemInternalVariable.new(model, EPlus::EMSIntVarFanMFR)
|
550
557
|
@fan_mfr_max_var[fan_coil].setName("#{fan_coil.name} max sup fan mfr")
|
551
558
|
@fan_mfr_max_var[fan_coil].setInternalDataIndexKeyName(supply_fan.name.to_s)
|
552
559
|
|
@@ -564,18 +571,6 @@ class Airflow
|
|
564
571
|
if duct.leakage_frac.nil? == duct.leakage_cfm25.nil?
|
565
572
|
fail 'Ducts: Must provide either leakage fraction or cfm25, but not both.'
|
566
573
|
end
|
567
|
-
if (not duct.leakage_frac.nil?) && ((duct.leakage_frac < 0) || (duct.leakage_frac > 1))
|
568
|
-
fail 'Ducts: Leakage Fraction must be greater than or equal to 0 and less than or equal to 1.'
|
569
|
-
end
|
570
|
-
if (not duct.leakage_cfm25.nil?) && (duct.leakage_cfm25 < 0)
|
571
|
-
fail 'Ducts: Leakage CFM25 must be greater than or equal to 0.'
|
572
|
-
end
|
573
|
-
if duct.rvalue < 0
|
574
|
-
fail 'Ducts: Insulation Nominal R-Value must be greater than or equal to 0.'
|
575
|
-
end
|
576
|
-
if duct.area < 0
|
577
|
-
fail 'Ducts: Surface Area must be greater than or equal to 0.'
|
578
|
-
end
|
579
574
|
end
|
580
575
|
|
581
576
|
ducts.each do |duct|
|
@@ -592,17 +587,6 @@ class Airflow
|
|
592
587
|
end
|
593
588
|
end
|
594
589
|
|
595
|
-
if ducts.size > 0
|
596
|
-
# Store info for HVAC Sizing measure
|
597
|
-
object.additionalProperties.setFeature(Constants.SizingInfoDuctExist, true)
|
598
|
-
object.additionalProperties.setFeature(Constants.SizingInfoDuctSides, ducts.map { |duct| duct.side }.join(','))
|
599
|
-
object.additionalProperties.setFeature(Constants.SizingInfoDuctLocations, ducts.map { |duct| duct.location.to_s }.join(','))
|
600
|
-
object.additionalProperties.setFeature(Constants.SizingInfoDuctLeakageFracs, ducts.map { |duct| duct.leakage_frac.to_f }.join(','))
|
601
|
-
object.additionalProperties.setFeature(Constants.SizingInfoDuctLeakageCFM25s, ducts.map { |duct| duct.leakage_cfm25.to_f }.join(','))
|
602
|
-
object.additionalProperties.setFeature(Constants.SizingInfoDuctAreas, ducts.map { |duct| duct.area.to_f }.join(','))
|
603
|
-
object.additionalProperties.setFeature(Constants.SizingInfoDuctRvalues, ducts.map { |duct| duct.rvalue.to_f }.join(','))
|
604
|
-
end
|
605
|
-
|
606
590
|
return if ducts.size == 0 # No ducts
|
607
591
|
|
608
592
|
# get duct located zone or ambient temperature schedule objects
|
@@ -866,7 +850,7 @@ class Airflow
|
|
866
850
|
zone_mixing = OpenStudio::Model::ZoneMixing.new(dest_zone)
|
867
851
|
zone_mixing.setName("#{object_name} mix")
|
868
852
|
zone_mixing.setSourceZone(source_zone)
|
869
|
-
duct_actuators[var_name] = OpenStudio::Model::EnergyManagementSystemActuator.new(zone_mixing,
|
853
|
+
duct_actuators[var_name] = OpenStudio::Model::EnergyManagementSystemActuator.new(zone_mixing, *EPlus::EMSActuatorZoneMixingFlowRate)
|
870
854
|
duct_actuators[var_name].setName("#{zone_mixing.name} act")
|
871
855
|
end
|
872
856
|
end
|
@@ -1107,7 +1091,7 @@ class Airflow
|
|
1107
1091
|
end
|
1108
1092
|
end
|
1109
1093
|
|
1110
|
-
def self.apply_infiltration_to_garage(model, weather, ach50)
|
1094
|
+
def self.apply_infiltration_to_garage(model, weather, site, ach50)
|
1111
1095
|
return if @spaces[HPXML::LocationGarage].nil?
|
1112
1096
|
|
1113
1097
|
space = @spaces[HPXML::LocationGarage]
|
@@ -1119,7 +1103,7 @@ class Airflow
|
|
1119
1103
|
ela = sla * area
|
1120
1104
|
ach = get_infiltration_ACH_from_SLA(sla, 8.202, weather)
|
1121
1105
|
cfm = ach / UnitConversions.convert(1.0, 'hr', 'min') * volume
|
1122
|
-
c_w_SG, c_s_SG = calc_wind_stack_coeffs(hor_lk_frac, neutral_level, space)
|
1106
|
+
c_w_SG, c_s_SG = calc_wind_stack_coeffs(site, hor_lk_frac, neutral_level, space)
|
1123
1107
|
apply_infiltration_to_unconditioned_space(model, space, nil, ela, c_w_SG, c_s_SG)
|
1124
1108
|
end
|
1125
1109
|
|
@@ -1131,9 +1115,6 @@ class Airflow
|
|
1131
1115
|
ach = 0.1 # Assumption
|
1132
1116
|
cfm = ach / UnitConversions.convert(1.0, 'hr', 'min') * volume
|
1133
1117
|
apply_infiltration_to_unconditioned_space(model, space, ach, nil, nil, nil)
|
1134
|
-
|
1135
|
-
# Store info for HVAC Sizing measure
|
1136
|
-
space.thermalZone.get.additionalProperties.setFeature(Constants.SizingInfoZoneInfiltrationCFM, cfm.to_f)
|
1137
1118
|
end
|
1138
1119
|
|
1139
1120
|
def self.apply_infiltration_to_vented_crawlspace(model, weather, vented_crawl)
|
@@ -1145,9 +1126,6 @@ class Airflow
|
|
1145
1126
|
ach = get_infiltration_ACH_from_SLA(sla, 8.202, weather)
|
1146
1127
|
cfm = ach / UnitConversions.convert(1.0, 'hr', 'min') * volume
|
1147
1128
|
apply_infiltration_to_unconditioned_space(model, space, ach, nil, nil, nil)
|
1148
|
-
|
1149
|
-
# Store info for HVAC Sizing measure
|
1150
|
-
space.thermalZone.get.additionalProperties.setFeature(Constants.SizingInfoZoneInfiltrationCFM, cfm.to_f)
|
1151
1129
|
end
|
1152
1130
|
|
1153
1131
|
def self.apply_infiltration_to_unvented_crawlspace(model, weather)
|
@@ -1159,16 +1137,17 @@ class Airflow
|
|
1159
1137
|
ach = get_infiltration_ACH_from_SLA(sla, 8.202, weather)
|
1160
1138
|
cfm = ach / UnitConversions.convert(1.0, 'hr', 'min') * volume
|
1161
1139
|
apply_infiltration_to_unconditioned_space(model, space, ach, nil, nil, nil)
|
1162
|
-
|
1163
|
-
# Store info for HVAC Sizing measure
|
1164
|
-
space.thermalZone.get.additionalProperties.setFeature(Constants.SizingInfoZoneInfiltrationCFM, cfm.to_f)
|
1165
1140
|
end
|
1166
1141
|
|
1167
|
-
def self.apply_infiltration_to_vented_attic(model, weather, vented_attic)
|
1142
|
+
def self.apply_infiltration_to_vented_attic(model, weather, site, vented_attic)
|
1168
1143
|
return if @spaces[HPXML::LocationAtticVented].nil?
|
1169
1144
|
|
1170
1145
|
if not vented_attic.vented_attic_sla.nil?
|
1171
|
-
|
1146
|
+
if @apply_ashrae140_assumptions
|
1147
|
+
vented_attic_const_ach = get_infiltration_ACH_from_SLA(vented_attic.vented_attic_sla, 8.202, weather)
|
1148
|
+
else
|
1149
|
+
vented_attic_sla = vented_attic.vented_attic_sla
|
1150
|
+
end
|
1172
1151
|
elsif not vented_attic.vented_attic_ach.nil?
|
1173
1152
|
if @apply_ashrae140_assumptions
|
1174
1153
|
vented_attic_const_ach = vented_attic.vented_attic_ach
|
@@ -1187,19 +1166,16 @@ class Airflow
|
|
1187
1166
|
ach = get_infiltration_ACH_from_SLA(sla, 8.202, weather)
|
1188
1167
|
ela = sla * vented_attic_area
|
1189
1168
|
cfm = ach / UnitConversions.convert(1.0, 'hr', 'min') * volume
|
1190
|
-
c_w_SG, c_s_SG = calc_wind_stack_coeffs(hor_lk_frac, neutral_level, space)
|
1169
|
+
c_w_SG, c_s_SG = calc_wind_stack_coeffs(site, hor_lk_frac, neutral_level, space)
|
1191
1170
|
apply_infiltration_to_unconditioned_space(model, space, nil, ela, c_w_SG, c_s_SG)
|
1192
1171
|
elsif not vented_attic_const_ach.nil?
|
1193
1172
|
ach = vented_attic_const_ach
|
1194
1173
|
cfm = ach / UnitConversions.convert(1.0, 'hr', 'min') * volume
|
1195
1174
|
apply_infiltration_to_unconditioned_space(model, space, ach, nil, nil, nil)
|
1196
1175
|
end
|
1197
|
-
|
1198
|
-
# Store info for HVAC Sizing measure
|
1199
|
-
space.thermalZone.get.additionalProperties.setFeature(Constants.SizingInfoZoneInfiltrationCFM, cfm.to_f)
|
1200
1176
|
end
|
1201
1177
|
|
1202
|
-
def self.apply_infiltration_to_unvented_attic(model, weather)
|
1178
|
+
def self.apply_infiltration_to_unvented_attic(model, weather, site)
|
1203
1179
|
return if @spaces[HPXML::LocationAtticUnvented].nil?
|
1204
1180
|
|
1205
1181
|
space = @spaces[HPXML::LocationAtticUnvented]
|
@@ -1211,11 +1187,8 @@ class Airflow
|
|
1211
1187
|
ach = get_infiltration_ACH_from_SLA(sla, 8.202, weather)
|
1212
1188
|
ela = sla * area
|
1213
1189
|
cfm = ach / UnitConversions.convert(1.0, 'hr', 'min') * volume
|
1214
|
-
c_w_SG, c_s_SG = calc_wind_stack_coeffs(hor_lk_frac, neutral_level, space)
|
1190
|
+
c_w_SG, c_s_SG = calc_wind_stack_coeffs(site, hor_lk_frac, neutral_level, space)
|
1215
1191
|
apply_infiltration_to_unconditioned_space(model, space, nil, ela, c_w_SG, c_s_SG)
|
1216
|
-
|
1217
|
-
# Store info for HVAC Sizing measure
|
1218
|
-
space.thermalZone.get.additionalProperties.setFeature(Constants.SizingInfoZoneInfiltrationCFM, cfm.to_f)
|
1219
1192
|
end
|
1220
1193
|
|
1221
1194
|
def self.apply_local_ventilation(model, vent_object_array, obj_type_name)
|
@@ -1254,10 +1227,10 @@ class Airflow
|
|
1254
1227
|
return obj_sch_sensors
|
1255
1228
|
end
|
1256
1229
|
|
1257
|
-
def self.apply_dryer_exhaust(model,
|
1230
|
+
def self.apply_dryer_exhaust(model, vented_dryers, schedules_file)
|
1258
1231
|
obj_sch_sensors = {}
|
1259
1232
|
obj_type_name = Constants.ObjectNameClothesDryerExhaust
|
1260
|
-
|
1233
|
+
vented_dryers.each_with_index do |vented_dryer, index|
|
1261
1234
|
obj_name = "#{obj_type_name} #{index}"
|
1262
1235
|
|
1263
1236
|
if not schedules_file.nil?
|
@@ -1274,7 +1247,7 @@ class Airflow
|
|
1274
1247
|
obj_sch_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Schedule Value')
|
1275
1248
|
obj_sch_sensor.setName("#{obj_name} sch s")
|
1276
1249
|
obj_sch_sensor.setKeyName(obj_sch_name)
|
1277
|
-
obj_sch_sensors[
|
1250
|
+
obj_sch_sensors[vented_dryer.id] = obj_sch_sensor
|
1278
1251
|
end
|
1279
1252
|
|
1280
1253
|
return obj_sch_sensors
|
@@ -1436,7 +1409,7 @@ class Airflow
|
|
1436
1409
|
vent_mech_fan_actuator = nil
|
1437
1410
|
if is_cfis # actuate its power level in EMS
|
1438
1411
|
equip_def.setFractionLost(0.0) # Fan heat does enter space
|
1439
|
-
vent_mech_fan_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(equip,
|
1412
|
+
vent_mech_fan_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(equip, *EPlus::EMSActuatorElectricEquipmentPower)
|
1440
1413
|
vent_mech_fan_actuator.setName("#{equip.name} act")
|
1441
1414
|
else
|
1442
1415
|
equip_def.setDesignLevel(pow)
|
@@ -1469,8 +1442,8 @@ class Airflow
|
|
1469
1442
|
return fan_sens_load_actuator, fan_lat_load_actuator
|
1470
1443
|
end
|
1471
1444
|
|
1472
|
-
def self.apply_infiltration_adjustment(infil_program, vent_fans_kitchen, vent_fans_bath,
|
1473
|
-
infil_flow_actuator,
|
1445
|
+
def self.apply_infiltration_adjustment(infil_program, vent_fans_kitchen, vent_fans_bath, vented_dryers, sup_cfm_tot, exh_cfm_tot, bal_cfm_tot, erv_hrv_cfm_tot,
|
1446
|
+
infil_flow_actuator, range_sch_sensors_map, bath_sch_sensors_map, dryer_exhaust_sch_sensors_map)
|
1474
1447
|
infil_program.addLine('Set Qrange = 0')
|
1475
1448
|
vent_fans_kitchen.each do |vent_kitchen|
|
1476
1449
|
infil_program.addLine("Set Qrange = Qrange + #{UnitConversions.convert(vent_kitchen.rated_flow_rate * vent_kitchen.quantity, 'cfm', 'm^3/s').round(4)} * #{range_sch_sensors_map[vent_kitchen.id].name}")
|
@@ -1482,10 +1455,8 @@ class Airflow
|
|
1482
1455
|
end
|
1483
1456
|
|
1484
1457
|
infil_program.addLine('Set Qdryer = 0')
|
1485
|
-
|
1486
|
-
|
1487
|
-
|
1488
|
-
infil_program.addLine("Set Qdryer = Qdryer + #{UnitConversions.convert(clothes_dryer.vented_flow_rate, 'cfm', 'm^3/s').round(4)} * #{dryer_exhaust_sch_sensors_map[clothes_dryer.id].name}")
|
1458
|
+
vented_dryers.each do |vented_dryer|
|
1459
|
+
infil_program.addLine("Set Qdryer = Qdryer + #{UnitConversions.convert(vented_dryer.vented_flow_rate, 'cfm', 'm^3/s').round(4)} * #{dryer_exhaust_sch_sensors_map[vented_dryer.id].name}")
|
1489
1460
|
end
|
1490
1461
|
|
1491
1462
|
infil_program.addLine("Set QWHV_sup = #{UnitConversions.convert(sup_cfm_tot, 'cfm', 'm^3/s').round(4)}")
|
@@ -1516,7 +1487,6 @@ class Airflow
|
|
1516
1487
|
infil_program.addLine('Set Qinf_adj = Qtot - Qu - Qb')
|
1517
1488
|
end
|
1518
1489
|
infil_program.addLine("Set #{infil_flow_actuator.name} = Qinf_adj")
|
1519
|
-
infil_program.addLine("Set #{cd_flow_actuator.name} = Qdryer")
|
1520
1490
|
end
|
1521
1491
|
|
1522
1492
|
def self.calculate_fan_loads(model, infil_program, vent_mech_erv_hrv_tot, hrv_erv_effectiveness_map, fan_sens_load_actuator, fan_lat_load_actuator, q_var, preconditioned = false)
|
@@ -1605,8 +1575,8 @@ class Airflow
|
|
1605
1575
|
end
|
1606
1576
|
end
|
1607
1577
|
|
1608
|
-
def self.
|
1609
|
-
|
1578
|
+
def self.apply_infiltration_and_mechanical_ventilation(model, site, vent_fans_mech, living_ach50, living_const_ach, weather, vent_fans_kitchen, vent_fans_bath, vented_dryers,
|
1579
|
+
range_sch_sensors_map, bath_sch_sensors_map, dryer_exhaust_sch_sensors_map, has_flue_chimney, hvac_map)
|
1610
1580
|
# Categorize fans into different types
|
1611
1581
|
vent_mech_preheat = vent_fans_mech.select { |vent_mech| (not vent_mech.preheating_efficiency_cop.nil?) }
|
1612
1582
|
vent_mech_precool = vent_fans_mech.select { |vent_mech| (not vent_mech.precooling_efficiency_cop.nil?) }
|
@@ -1641,60 +1611,23 @@ class Airflow
|
|
1641
1611
|
exh_cfm_tot = vent_mech_exh_tot.map { |vent_mech| vent_mech.average_total_unit_flow_rate }.sum(0.0)
|
1642
1612
|
bal_cfm_tot = vent_mech_bal_tot.map { |vent_mech| vent_mech.average_total_unit_flow_rate }.sum(0.0)
|
1643
1613
|
erv_hrv_cfm_tot = vent_mech_erv_hrv_tot.map { |vent_mech| vent_mech.average_total_unit_flow_rate }.sum(0.0)
|
1644
|
-
cfis_cfm_tot = vent_mech_cfis_tot.map { |vent_mech| vent_mech.average_total_unit_flow_rate }.sum(0.0)
|
1645
|
-
|
1646
|
-
# Average preconditioned oa air cfms (only oa, recirculation will be addressed below for all shared systems)
|
1647
|
-
oa_cfm_preheat = vent_mech_preheat.map { |vent_mech| vent_mech.average_oa_unit_flow_rate * vent_mech.preheating_fraction_load_served }.sum(0.0)
|
1648
|
-
oa_cfm_precool = vent_mech_precool.map { |vent_mech| vent_mech.average_oa_unit_flow_rate * vent_mech.precooling_fraction_load_served }.sum(0.0)
|
1649
|
-
recirc_cfm_shared = vent_mech_shared.map { |vent_mech| vent_mech.average_total_unit_flow_rate - vent_mech.average_oa_unit_flow_rate }.sum(0.0)
|
1650
|
-
|
1651
|
-
# HVAC Sizing data
|
1652
|
-
tot_sup_cfm = sup_cfm_tot + bal_cfm_tot + erv_hrv_cfm_tot + cfis_cfm_tot
|
1653
|
-
tot_exh_cfm = exh_cfm_tot + bal_cfm_tot + erv_hrv_cfm_tot
|
1654
|
-
tot_unbal_cfm = (tot_sup_cfm - tot_exh_cfm).abs
|
1655
|
-
tot_bal_cfm = [tot_exh_cfm, tot_sup_cfm].min
|
1656
1614
|
|
1657
1615
|
# Calculate effectivenesses for all ERV/HRV and store results in a hash
|
1658
1616
|
hrv_erv_effectiveness_map = calc_hrv_erv_effectiveness(vent_mech_erv_hrv_tot)
|
1659
1617
|
|
1660
|
-
# Calculate cfm weighted average effectivenesses for the combined balanced airflow
|
1661
|
-
weighted_vent_mech_lat_eff = 0.0
|
1662
|
-
weighted_vent_mech_apparent_sens_eff = 0.0
|
1663
|
-
vent_mech_erv_hrv_unprecond = vent_mech_erv_hrv_tot.select { |vent_mech| vent_mech.preheating_efficiency_cop.nil? && vent_mech.precooling_efficiency_cop.nil? }
|
1664
|
-
vent_mech_erv_hrv_unprecond.each do |vent_mech|
|
1665
|
-
weighted_vent_mech_lat_eff += vent_mech.average_oa_unit_flow_rate / tot_bal_cfm * hrv_erv_effectiveness_map[vent_mech][:vent_mech_lat_eff]
|
1666
|
-
weighted_vent_mech_apparent_sens_eff += vent_mech.average_oa_unit_flow_rate / tot_bal_cfm * hrv_erv_effectiveness_map[vent_mech][:vent_mech_apparent_sens_eff]
|
1667
|
-
end
|
1668
|
-
# Store info for HVAC Sizing measure
|
1669
|
-
model.getBuilding.additionalProperties.setFeature(Constants.SizingInfoMechVentLatentEffectiveness, weighted_vent_mech_lat_eff)
|
1670
|
-
model.getBuilding.additionalProperties.setFeature(Constants.SizingInfoMechVentApparentSensibleEffectiveness, weighted_vent_mech_apparent_sens_eff)
|
1671
|
-
model.getBuilding.additionalProperties.setFeature(Constants.SizingInfoMechVentWholeHouseRateBalanced, tot_bal_cfm)
|
1672
|
-
model.getBuilding.additionalProperties.setFeature(Constants.SizingInfoMechVentWholeHouseRateUnbalanced, tot_unbal_cfm)
|
1673
|
-
model.getBuilding.additionalProperties.setFeature(Constants.SizingInfoMechVentWholeHouseRatePreHeated, oa_cfm_preheat)
|
1674
|
-
model.getBuilding.additionalProperties.setFeature(Constants.SizingInfoMechVentWholeHouseRatePreCooled, oa_cfm_precool)
|
1675
|
-
model.getBuilding.additionalProperties.setFeature(Constants.SizingInfoMechVentWholeHouseRateRecirculated, recirc_cfm_shared)
|
1676
|
-
model.getBuilding.additionalProperties.setFeature(Constants.SizingInfoMechVentExist, (not vent_fans_mech.empty?))
|
1677
|
-
|
1678
1618
|
infil_flow = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
|
1679
1619
|
infil_flow.setName(Constants.ObjectNameInfiltration + ' flow')
|
1680
1620
|
infil_flow.setSchedule(model.alwaysOnDiscreteSchedule)
|
1681
1621
|
infil_flow.setSpace(@living_space)
|
1682
|
-
infil_flow_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(infil_flow,
|
1622
|
+
infil_flow_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(infil_flow, *EPlus::EMSActuatorZoneInfiltrationFlowRate)
|
1683
1623
|
infil_flow_actuator.setName("#{infil_flow.name} act")
|
1684
1624
|
|
1685
|
-
cd_flow = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
|
1686
|
-
cd_flow.setName(Constants.ObjectNameClothesDryerExhaust + ' flow')
|
1687
|
-
cd_flow.setSchedule(model.alwaysOnDiscreteSchedule)
|
1688
|
-
cd_flow.setSpace(@living_space)
|
1689
|
-
cd_flow_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(cd_flow, 'Zone Infiltration', 'Air Exchange Flow Rate')
|
1690
|
-
cd_flow_actuator.setName("#{cd_flow.name} act")
|
1691
|
-
|
1692
1625
|
# Living Space Infiltration Calculation/Program
|
1693
1626
|
infil_program = OpenStudio::Model::EnergyManagementSystemProgram.new(model)
|
1694
1627
|
infil_program.setName(Constants.ObjectNameInfiltration + ' program')
|
1695
1628
|
|
1696
1629
|
# Calculate infiltration without adjustment by ventilation
|
1697
|
-
apply_infiltration_to_living(living_ach50, living_const_ach, infil_program, weather, has_flue_chimney)
|
1630
|
+
apply_infiltration_to_living(site, living_ach50, living_const_ach, infil_program, weather, has_flue_chimney)
|
1698
1631
|
|
1699
1632
|
# Common variable and load actuators across multiple mech vent calculations, create only once
|
1700
1633
|
fan_sens_load_actuator, fan_lat_load_actuator = setup_mech_vent_vars_actuators(model: model, program: infil_program)
|
@@ -1705,8 +1638,8 @@ class Airflow
|
|
1705
1638
|
|
1706
1639
|
# Calculate Qfan, Qinf_adj
|
1707
1640
|
# Calculate adjusted infiltration based on mechanical ventilation system
|
1708
|
-
apply_infiltration_adjustment(infil_program, vent_fans_kitchen, vent_fans_bath,
|
1709
|
-
infil_flow_actuator,
|
1641
|
+
apply_infiltration_adjustment(infil_program, vent_fans_kitchen, vent_fans_bath, vented_dryers, sup_cfm_tot, exh_cfm_tot, bal_cfm_tot, erv_hrv_cfm_tot,
|
1642
|
+
infil_flow_actuator, range_sch_sensors_map, bath_sch_sensors_map, dryer_exhaust_sch_sensors_map)
|
1710
1643
|
|
1711
1644
|
# Address load of Qfan (Qload)
|
1712
1645
|
# Qload as variable for tracking outdoor air flow rate, excluding recirculation
|
@@ -1726,18 +1659,18 @@ class Airflow
|
|
1726
1659
|
program_calling_manager.addProgram(infil_program)
|
1727
1660
|
end
|
1728
1661
|
|
1729
|
-
def self.apply_infiltration_and_ventilation_fans(model, weather, vent_fans_mech, vent_fans_kitchen, vent_fans_bath,
|
1662
|
+
def self.apply_infiltration_and_ventilation_fans(model, weather, site, vent_fans_mech, vent_fans_kitchen, vent_fans_bath, vented_dryers,
|
1730
1663
|
has_flue_chimney, air_infils, vented_attic, vented_crawl, hvac_map, schedules_file)
|
1731
1664
|
# Get living space infiltration
|
1732
1665
|
living_ach50 = nil
|
1733
1666
|
living_const_ach = nil
|
1734
1667
|
air_infils.each do |air_infil|
|
1735
1668
|
if (air_infil.unit_of_measure == HPXML::UnitsACH) && !air_infil.house_pressure.nil?
|
1736
|
-
|
1737
|
-
living_ach50 = calc_air_leakage_at_diff_pressure(0.65,
|
1669
|
+
living_achXX = air_infil.air_leakage
|
1670
|
+
living_ach50 = calc_air_leakage_at_diff_pressure(0.65, living_achXX, air_infil.house_pressure, 50.0)
|
1738
1671
|
elsif (air_infil.unit_of_measure == HPXML::UnitsCFM) && !air_infil.house_pressure.nil?
|
1739
|
-
|
1740
|
-
living_ach50 = calc_air_leakage_at_diff_pressure(0.65,
|
1672
|
+
living_achXX = air_infil.air_leakage * 60.0 / @infil_volume # Convert CFM to ACH
|
1673
|
+
living_ach50 = calc_air_leakage_at_diff_pressure(0.65, living_achXX, air_infil.house_pressure, 50.0)
|
1741
1674
|
elsif air_infil.unit_of_measure == HPXML::UnitsACHNatural
|
1742
1675
|
if @apply_ashrae140_assumptions
|
1743
1676
|
living_const_ach = air_infil.air_leakage
|
@@ -1749,26 +1682,28 @@ class Airflow
|
|
1749
1682
|
end
|
1750
1683
|
|
1751
1684
|
# Infiltration for unconditioned spaces
|
1752
|
-
apply_infiltration_to_garage(model, weather, living_ach50)
|
1685
|
+
apply_infiltration_to_garage(model, weather, site, living_ach50)
|
1753
1686
|
apply_infiltration_to_unconditioned_basement(model, weather)
|
1754
1687
|
apply_infiltration_to_vented_crawlspace(model, weather, vented_crawl)
|
1755
1688
|
apply_infiltration_to_unvented_crawlspace(model, weather)
|
1756
|
-
apply_infiltration_to_vented_attic(model, weather, vented_attic)
|
1757
|
-
apply_infiltration_to_unvented_attic(model, weather)
|
1689
|
+
apply_infiltration_to_vented_attic(model, weather, site, vented_attic)
|
1690
|
+
apply_infiltration_to_unvented_attic(model, weather, site)
|
1758
1691
|
|
1759
1692
|
# Local ventilation
|
1760
1693
|
range_sch_sensors_map = apply_local_ventilation(model, vent_fans_kitchen, Constants.ObjectNameMechanicalVentilationRangeFan)
|
1761
1694
|
bath_sch_sensors_map = apply_local_ventilation(model, vent_fans_bath, Constants.ObjectNameMechanicalVentilationBathFan)
|
1762
1695
|
|
1763
1696
|
# Clothes dryer exhaust
|
1764
|
-
dryer_exhaust_sch_sensors_map = apply_dryer_exhaust(model,
|
1697
|
+
dryer_exhaust_sch_sensors_map = apply_dryer_exhaust(model, vented_dryers, schedules_file)
|
1765
1698
|
|
1766
1699
|
# Get mechanical ventilation
|
1767
|
-
|
1768
|
-
|
1700
|
+
apply_infiltration_and_mechanical_ventilation(model, site, vent_fans_mech, living_ach50, living_const_ach, weather, vent_fans_kitchen, vent_fans_bath, vented_dryers,
|
1701
|
+
range_sch_sensors_map, bath_sch_sensors_map, dryer_exhaust_sch_sensors_map, has_flue_chimney, hvac_map)
|
1769
1702
|
end
|
1770
1703
|
|
1771
|
-
def self.apply_infiltration_to_living(living_ach50, living_const_ach, infil_program, weather, has_flue_chimney)
|
1704
|
+
def self.apply_infiltration_to_living(site, living_ach50, living_const_ach, infil_program, weather, has_flue_chimney)
|
1705
|
+
site_ap = site.additional_properties
|
1706
|
+
|
1772
1707
|
if living_ach50.to_f > 0
|
1773
1708
|
# Based on "Field Validation of Algebraic Equations for Stack and
|
1774
1709
|
# Wind Driven Air Infiltration Calculations" by Walker and Wilson (1998)
|
@@ -1786,11 +1721,9 @@ class Airflow
|
|
1786
1721
|
|
1787
1722
|
if has_flue_chimney
|
1788
1723
|
y_i = 0.2 # Fraction of leakage through the flue; 0.2 is a "typical" value according to THE ALBERTA AIR INFIL1RATION MODEL, Walker and Wilson, 1990
|
1789
|
-
flue_height = @building_height + 2.0 # ft
|
1790
1724
|
s_wflue = 1.0 # Flue Shelter Coefficient
|
1791
1725
|
else
|
1792
1726
|
y_i = 0.0 # Fraction of leakage through the flu
|
1793
|
-
flue_height = 0.0 # ft
|
1794
1727
|
s_wflue = 0.0 # Flue Shelter Coefficient
|
1795
1728
|
end
|
1796
1729
|
|
@@ -1811,7 +1744,6 @@ class Airflow
|
|
1811
1744
|
x_i = (leakage_ceiling - leakage_floor)
|
1812
1745
|
r_i *= (1 - y_i)
|
1813
1746
|
x_i *= (1 - y_i)
|
1814
|
-
z_f = flue_height / (@infil_height + Geometry.get_z_origin_for_zone(@living_zone))
|
1815
1747
|
|
1816
1748
|
# Calculate Stack Coefficient
|
1817
1749
|
m_o = (x_i + (2.0 * n_i + 1.0) * y_i)**2.0 / (2 - r_i)
|
@@ -1821,6 +1753,11 @@ class Airflow
|
|
1821
1753
|
m_i = 1.0 # eq. 11
|
1822
1754
|
end
|
1823
1755
|
if has_flue_chimney
|
1756
|
+
if @ncfl_ag <= 0
|
1757
|
+
z_f = 1.0
|
1758
|
+
else
|
1759
|
+
z_f = (@ncfl_ag + 0.5) / @ncfl_ag # Typical value is 1.5 according to THE ALBERTA AIR INFIL1RATION MODEL, Walker and Wilson, 1990, presumably for a single story home
|
1760
|
+
end
|
1824
1761
|
x_c = r_i + (2.0 * (1.0 - r_i - y_i)) / (n_i + 1.0) - 2.0 * y_i * (z_f - 1.0)**n_i # Eq. 13
|
1825
1762
|
f_i = n_i * y_i * (z_f - 1.0)**((3.0 * n_i - 1.0) / 3.0) * (1.0 - (3.0 * (x_c - x_i)**2.0 * r_i**(1 - n_i)) / (2.0 * (z_f + 1.0))) # Additive flue function, Eq. 12
|
1826
1763
|
else
|
@@ -1850,11 +1787,11 @@ class Airflow
|
|
1850
1787
|
living_ach = get_infiltration_ACH_from_SLA(living_sla, @infil_height, weather)
|
1851
1788
|
living_cfm = living_ach / UnitConversions.convert(1.0, 'hr', 'min') * @infil_volume
|
1852
1789
|
|
1853
|
-
infil_program.addLine("Set p_m = #{
|
1854
|
-
infil_program.addLine("Set p_s = #{
|
1855
|
-
infil_program.addLine("Set s_m = #{
|
1856
|
-
infil_program.addLine("Set s_s = #{
|
1857
|
-
infil_program.addLine("Set z_m = #{UnitConversions.convert(
|
1790
|
+
infil_program.addLine("Set p_m = #{site_ap.ashrae_terrain_exponent}")
|
1791
|
+
infil_program.addLine("Set p_s = #{site_ap.ashrae_site_terrain_exponent}")
|
1792
|
+
infil_program.addLine("Set s_m = #{site_ap.ashrae_terrain_thickness}")
|
1793
|
+
infil_program.addLine("Set s_s = #{site_ap.ashrae_site_terrain_thickness}")
|
1794
|
+
infil_program.addLine("Set z_m = #{UnitConversions.convert(site_ap.height, 'ft', 'm')}")
|
1858
1795
|
infil_program.addLine("Set z_s = #{UnitConversions.convert(@infil_height, 'ft', 'm')}")
|
1859
1796
|
infil_program.addLine('Set f_t = (((s_m/z_m)^p_m)*((z_s/s_s)^p_s))')
|
1860
1797
|
infil_program.addLine("Set Tdiff = #{@tin_sensor.name}-#{@tout_sensor.name}")
|
@@ -1863,7 +1800,7 @@ class Airflow
|
|
1863
1800
|
infil_program.addLine("Set Cs = #{(stack_coef * (UnitConversions.convert(1.0, 'inH2O/R', 'Pa/K')**n_i)).round(4)}")
|
1864
1801
|
infil_program.addLine("Set Cw = #{(wind_coef * (UnitConversions.convert(1.0, 'inH2O/mph^2', 'Pa*s^2/m^2')**n_i)).round(4)}")
|
1865
1802
|
infil_program.addLine("Set n = #{n_i}")
|
1866
|
-
infil_program.addLine("Set sft = (f_t*#{(((
|
1803
|
+
infil_program.addLine("Set sft = (f_t*#{(((site_ap.aim2_shelter_coeff * (1.0 - y_i)) + (s_wflue * (1.5 * y_i))))})")
|
1867
1804
|
infil_program.addLine("Set temp1 = ((c*Cw)*((sft*#{@vwind_sensor.name})^(2*n)))^2")
|
1868
1805
|
infil_program.addLine('Set Qinf = (((c*Cs*(dT^n))^2)+temp1)^0.5')
|
1869
1806
|
infil_program.addLine('Set Qinf = (@Max Qinf 0)')
|
@@ -1877,20 +1814,17 @@ class Airflow
|
|
1877
1814
|
else
|
1878
1815
|
infil_program.addLine('Set Qinf = 0')
|
1879
1816
|
end
|
1880
|
-
|
1881
|
-
# Store info for HVAC Sizing measure
|
1882
|
-
@living_zone.additionalProperties.setFeature(Constants.SizingInfoZoneInfiltrationCFM, living_cfm.to_f)
|
1883
|
-
@living_zone.additionalProperties.setFeature(Constants.SizingInfoZoneInfiltrationACH, living_ach.to_f)
|
1884
1817
|
end
|
1885
1818
|
|
1886
|
-
def self.calc_wind_stack_coeffs(hor_lk_frac, neutral_level, space, space_height = nil)
|
1819
|
+
def self.calc_wind_stack_coeffs(site, hor_lk_frac, neutral_level, space, space_height = nil)
|
1820
|
+
site_ap = site.additional_properties
|
1887
1821
|
if space_height.nil?
|
1888
1822
|
space_height = Geometry.get_height_of_spaces([space])
|
1889
1823
|
end
|
1890
1824
|
coord_z = Geometry.get_z_origin_for_zone(space.thermalZone.get)
|
1891
|
-
f_t_SG =
|
1825
|
+
f_t_SG = site_ap.site_terrain_multiplier * ((space_height + coord_z) / 32.8)**site_ap.site_terrain_exponent / (site_ap.terrain_multiplier * (site_ap.height / 32.8)**site_ap.terrain_exponent)
|
1892
1826
|
f_s_SG = 2.0 / 3.0 * (1 + hor_lk_frac / 2.0) * (2.0 * neutral_level * (1.0 - neutral_level))**0.5 / (neutral_level**0.5 + (1.0 - neutral_level)**0.5)
|
1893
|
-
f_w_SG =
|
1827
|
+
f_w_SG = site_ap.s_g_shielding_coef * (1.0 - hor_lk_frac)**(1.0 / 3.0) * f_t_SG
|
1894
1828
|
c_s_SG = f_s_SG**2.0 * Constants.g * space_height / (Constants.AssumedInsideTemp + 460.0)
|
1895
1829
|
c_w_SG = f_w_SG**2.0
|
1896
1830
|
return c_w_SG, c_s_SG
|
@@ -1976,9 +1910,3 @@ class Duct
|
|
1976
1910
|
end
|
1977
1911
|
attr_accessor(:side, :loc_space, :loc_schedule, :leakage_frac, :leakage_cfm25, :area, :rvalue, :zone, :location)
|
1978
1912
|
end
|
1979
|
-
|
1980
|
-
class WindSpeed
|
1981
|
-
def initialize
|
1982
|
-
end
|
1983
|
-
attr_accessor(:height, :terrain_multiplier, :terrain_exponent, :ashrae_terrain_thickness, :ashrae_terrain_exponent, :site_terrain_multiplier, :site_terrain_exponent, :ashrae_site_terrain_thickness, :ashrae_site_terrain_exponent, :S_wo, :shielding_coef)
|
1984
|
-
end
|