openstudio-standards 0.4.0 → 0.5.0
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/LICENSE.md +33 -0
- data/data/inventory/thermal_bridging.csv +90 -0
- data/data/standards/OpenStudio_Standards-deer-comstock.xlsx +0 -0
- data/data/standards/manage_OpenStudio_Standards.rb +1 -1
- data/data/standards/test_performance_expected_dd_results.csv +2014 -1891
- data/lib/openstudio-standards/btap/analysis.rb +8 -8
- data/lib/openstudio-standards/btap/bridging.rb +664 -645
- data/lib/openstudio-standards/btap/btap.model.rb +14 -14
- data/lib/openstudio-standards/btap/btap.rb +7 -7
- data/lib/openstudio-standards/btap/btap_result.rb +1 -1
- data/lib/openstudio-standards/btap/economics.rb +23 -23
- data/lib/openstudio-standards/btap/envelope.rb +8 -8
- data/lib/openstudio-standards/btap/equest.rb +1 -1
- data/lib/openstudio-standards/btap/geometry.rb +2 -2
- data/lib/openstudio-standards/btap/mpc.rb +7 -7
- data/lib/openstudio-standards/btap/schedules.rb +1 -1
- data/lib/openstudio-standards/btap/simmanager.rb +4 -4
- data/lib/openstudio-standards/btap/spaceloads.rb +26 -26
- data/lib/openstudio-standards/btap/utilities.rb +6 -6
- data/lib/openstudio-standards/btap/vintagizer.rb +1 -1
- data/lib/openstudio-standards/constructions/information.rb +83 -0
- data/lib/openstudio-standards/constructions/materials/modify.rb +72 -0
- data/lib/openstudio-standards/constructions/modify.rb +80 -0
- data/lib/openstudio-standards/create_typical/create_typical.rb +983 -0
- data/lib/openstudio-standards/create_typical/enumerations.rb +484 -0
- data/lib/openstudio-standards/create_typical/space_type_blend.rb +791 -0
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +494 -0
- data/lib/openstudio-standards/daylighting/space.rb +47 -0
- data/lib/openstudio-standards/geometry/create.rb +801 -0
- data/lib/openstudio-standards/geometry/create_bar.rb +2170 -0
- data/lib/openstudio-standards/geometry/information.rb +462 -0
- data/lib/openstudio-standards/geometry/modify.rb +48 -0
- data/lib/openstudio-standards/hvac/air_loop/information.rb +79 -0
- data/lib/openstudio-standards/hvac/cbecs_hvac.rb +616 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +91 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +2 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +3 -3
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +14 -14
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +16 -16
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +13 -13
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +18 -18
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +957 -957
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +84 -16
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +61 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +43 -30
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +774 -117
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +340 -481
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +22 -22
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/qaqc/calibration.rb +131 -0
- data/lib/openstudio-standards/qaqc/create_results.rb +983 -0
- data/lib/openstudio-standards/qaqc/envelope.rb +399 -0
- data/lib/openstudio-standards/qaqc/eui.rb +213 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +1943 -0
- data/lib/openstudio-standards/qaqc/internal_loads.rb +568 -0
- data/lib/openstudio-standards/qaqc/reporting.rb +141 -0
- data/lib/openstudio-standards/qaqc/schedules.rb +129 -0
- data/lib/openstudio-standards/qaqc/service_water_heating.rb +273 -0
- data/lib/openstudio-standards/qaqc/weather_files.rb +497 -0
- data/lib/openstudio-standards/qaqc/zone_conditions.rb +278 -0
- data/lib/openstudio-standards/schedules/create.rb +364 -0
- data/lib/openstudio-standards/schedules/information.rb +169 -0
- data/lib/openstudio-standards/schedules/modify.rb +445 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +110 -71
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +16 -10
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Construction.rb +17 -18
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +6 -6
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +6 -12
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.Model.rb +411 -261
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -29
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +14 -14
- data/lib/openstudio-standards/standards/Standards.Space.rb +37 -30
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +38 -29
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.Surface.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +109 -66
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +11 -4
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +5 -21
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +36 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +53 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +211 -211
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +22 -28
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater.rb +1 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +7 -59
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -21
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb +101 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +643 -526
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface.rb +8 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +17 -77
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +74 -16
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +96 -44
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Surface.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone.rb +18 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +328 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +0 -118
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_rejection.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md +35 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_plug_load_measures.md +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +228 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +131 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_space.csv +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +109 -27
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +18 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json +260 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.economizers.json +246 -4
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +5 -2
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json +25 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chillers.json +44 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +225 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +2 -2
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +193 -73
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +10 -4
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +4 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json +32 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +36 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm +47587 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm +49764 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Warehouse.osm +283 -297
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_type_unit_definitions.txt +2 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/NECB2011/data/standards_data.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +49 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +400 -202
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +18 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +615 -307
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +10 -5
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +1 -1
- data/lib/openstudio-standards/utilities/assertion.rb +128 -0
- data/lib/openstudio-standards/utilities/logging.rb +2 -3
- data/lib/openstudio-standards/utilities/object_info.rb +39 -18
- data/lib/openstudio-standards/utilities/schedule_translator.rb +8 -6
- data/lib/openstudio-standards/utilities/simulation.rb +24 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +10 -5
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +8 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +3 -3
- data/lib/openstudio-standards/weather/information.rb +35 -0
- data/lib/openstudio-standards.rb +69 -5
- metadata +54 -18
- data/License.txt +0 -65
- data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +0 -59
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb +0 -13
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +0 -36
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +0 -898
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +0 -126
- data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +0 -356
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +0 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb +0 -110
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb +0 -5
@@ -33,7 +33,8 @@
|
|
33
33
|
"high_bay_lighting_schedule": null,
|
34
34
|
"specialty_lighting_schedule": null,
|
35
35
|
"exit_lighting_schedule": null,
|
36
|
-
"target_illuminance_setpoint":
|
36
|
+
"target_illuminance_setpoint": 400,
|
37
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
37
38
|
"psa_nongeometry_fraction": null,
|
38
39
|
"ssa_nongeometry_fraction": null,
|
39
40
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -114,7 +115,8 @@
|
|
114
115
|
"high_bay_lighting_schedule": null,
|
115
116
|
"specialty_lighting_schedule": null,
|
116
117
|
"exit_lighting_schedule": null,
|
117
|
-
"target_illuminance_setpoint":
|
118
|
+
"target_illuminance_setpoint": 300,
|
119
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
118
120
|
"psa_nongeometry_fraction": null,
|
119
121
|
"ssa_nongeometry_fraction": null,
|
120
122
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -195,7 +197,8 @@
|
|
195
197
|
"high_bay_lighting_schedule": null,
|
196
198
|
"specialty_lighting_schedule": null,
|
197
199
|
"exit_lighting_schedule": null,
|
198
|
-
"target_illuminance_setpoint":
|
200
|
+
"target_illuminance_setpoint": 400,
|
201
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
199
202
|
"psa_nongeometry_fraction": null,
|
200
203
|
"ssa_nongeometry_fraction": null,
|
201
204
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -276,7 +279,8 @@
|
|
276
279
|
"high_bay_lighting_schedule": null,
|
277
280
|
"specialty_lighting_schedule": null,
|
278
281
|
"exit_lighting_schedule": null,
|
279
|
-
"target_illuminance_setpoint":
|
282
|
+
"target_illuminance_setpoint": 125,
|
283
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
280
284
|
"psa_nongeometry_fraction": null,
|
281
285
|
"ssa_nongeometry_fraction": null,
|
282
286
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -357,7 +361,8 @@
|
|
357
361
|
"high_bay_lighting_schedule": null,
|
358
362
|
"specialty_lighting_schedule": null,
|
359
363
|
"exit_lighting_schedule": null,
|
360
|
-
"target_illuminance_setpoint":
|
364
|
+
"target_illuminance_setpoint": 300,
|
365
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
361
366
|
"psa_nongeometry_fraction": null,
|
362
367
|
"ssa_nongeometry_fraction": null,
|
363
368
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -438,7 +443,8 @@
|
|
438
443
|
"high_bay_lighting_schedule": null,
|
439
444
|
"specialty_lighting_schedule": null,
|
440
445
|
"exit_lighting_schedule": null,
|
441
|
-
"target_illuminance_setpoint":
|
446
|
+
"target_illuminance_setpoint": 300,
|
447
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
442
448
|
"psa_nongeometry_fraction": null,
|
443
449
|
"ssa_nongeometry_fraction": null,
|
444
450
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -519,7 +525,8 @@
|
|
519
525
|
"high_bay_lighting_schedule": null,
|
520
526
|
"specialty_lighting_schedule": null,
|
521
527
|
"exit_lighting_schedule": null,
|
522
|
-
"target_illuminance_setpoint":
|
528
|
+
"target_illuminance_setpoint": 100,
|
529
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
523
530
|
"psa_nongeometry_fraction": null,
|
524
531
|
"ssa_nongeometry_fraction": null,
|
525
532
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -600,7 +607,8 @@
|
|
600
607
|
"high_bay_lighting_schedule": null,
|
601
608
|
"specialty_lighting_schedule": null,
|
602
609
|
"exit_lighting_schedule": null,
|
603
|
-
"target_illuminance_setpoint":
|
610
|
+
"target_illuminance_setpoint": 350,
|
611
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
604
612
|
"psa_nongeometry_fraction": null,
|
605
613
|
"ssa_nongeometry_fraction": null,
|
606
614
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -681,7 +689,8 @@
|
|
681
689
|
"high_bay_lighting_schedule": null,
|
682
690
|
"specialty_lighting_schedule": null,
|
683
691
|
"exit_lighting_schedule": null,
|
684
|
-
"target_illuminance_setpoint":
|
692
|
+
"target_illuminance_setpoint": 400,
|
693
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
685
694
|
"psa_nongeometry_fraction": null,
|
686
695
|
"ssa_nongeometry_fraction": null,
|
687
696
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -762,7 +771,8 @@
|
|
762
771
|
"high_bay_lighting_schedule": null,
|
763
772
|
"specialty_lighting_schedule": null,
|
764
773
|
"exit_lighting_schedule": null,
|
765
|
-
"target_illuminance_setpoint":
|
774
|
+
"target_illuminance_setpoint": 500,
|
775
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
766
776
|
"psa_nongeometry_fraction": null,
|
767
777
|
"ssa_nongeometry_fraction": null,
|
768
778
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -843,7 +853,8 @@
|
|
843
853
|
"high_bay_lighting_schedule": null,
|
844
854
|
"specialty_lighting_schedule": null,
|
845
855
|
"exit_lighting_schedule": null,
|
846
|
-
"target_illuminance_setpoint":
|
856
|
+
"target_illuminance_setpoint": 600,
|
857
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
847
858
|
"psa_nongeometry_fraction": null,
|
848
859
|
"ssa_nongeometry_fraction": null,
|
849
860
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -924,7 +935,8 @@
|
|
924
935
|
"high_bay_lighting_schedule": null,
|
925
936
|
"specialty_lighting_schedule": null,
|
926
937
|
"exit_lighting_schedule": null,
|
927
|
-
"target_illuminance_setpoint":
|
938
|
+
"target_illuminance_setpoint": 350,
|
939
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
928
940
|
"psa_nongeometry_fraction": null,
|
929
941
|
"ssa_nongeometry_fraction": null,
|
930
942
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -1005,7 +1017,8 @@
|
|
1005
1017
|
"high_bay_lighting_schedule": null,
|
1006
1018
|
"specialty_lighting_schedule": null,
|
1007
1019
|
"exit_lighting_schedule": null,
|
1008
|
-
"target_illuminance_setpoint":
|
1020
|
+
"target_illuminance_setpoint": 150,
|
1021
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1009
1022
|
"psa_nongeometry_fraction": null,
|
1010
1023
|
"ssa_nongeometry_fraction": null,
|
1011
1024
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1086,7 +1099,8 @@
|
|
1086
1099
|
"high_bay_lighting_schedule": null,
|
1087
1100
|
"specialty_lighting_schedule": null,
|
1088
1101
|
"exit_lighting_schedule": null,
|
1089
|
-
"target_illuminance_setpoint":
|
1102
|
+
"target_illuminance_setpoint": 500,
|
1103
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1090
1104
|
"psa_nongeometry_fraction": null,
|
1091
1105
|
"ssa_nongeometry_fraction": null,
|
1092
1106
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1167,7 +1181,8 @@
|
|
1167
1181
|
"high_bay_lighting_schedule": null,
|
1168
1182
|
"specialty_lighting_schedule": null,
|
1169
1183
|
"exit_lighting_schedule": null,
|
1170
|
-
"target_illuminance_setpoint":
|
1184
|
+
"target_illuminance_setpoint": 400,
|
1185
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1171
1186
|
"psa_nongeometry_fraction": null,
|
1172
1187
|
"ssa_nongeometry_fraction": null,
|
1173
1188
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1248,7 +1263,8 @@
|
|
1248
1263
|
"high_bay_lighting_schedule": null,
|
1249
1264
|
"specialty_lighting_schedule": null,
|
1250
1265
|
"exit_lighting_schedule": null,
|
1251
|
-
"target_illuminance_setpoint":
|
1266
|
+
"target_illuminance_setpoint": 400,
|
1267
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1252
1268
|
"psa_nongeometry_fraction": null,
|
1253
1269
|
"ssa_nongeometry_fraction": null,
|
1254
1270
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1329,7 +1345,8 @@
|
|
1329
1345
|
"high_bay_lighting_schedule": null,
|
1330
1346
|
"specialty_lighting_schedule": null,
|
1331
1347
|
"exit_lighting_schedule": null,
|
1332
|
-
"target_illuminance_setpoint":
|
1348
|
+
"target_illuminance_setpoint": 450,
|
1349
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1333
1350
|
"psa_nongeometry_fraction": null,
|
1334
1351
|
"ssa_nongeometry_fraction": null,
|
1335
1352
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1410,7 +1427,8 @@
|
|
1410
1427
|
"high_bay_lighting_schedule": null,
|
1411
1428
|
"specialty_lighting_schedule": null,
|
1412
1429
|
"exit_lighting_schedule": null,
|
1413
|
-
"target_illuminance_setpoint":
|
1430
|
+
"target_illuminance_setpoint": 150,
|
1431
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1414
1432
|
"psa_nongeometry_fraction": null,
|
1415
1433
|
"ssa_nongeometry_fraction": null,
|
1416
1434
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1491,7 +1509,8 @@
|
|
1491
1509
|
"high_bay_lighting_schedule": null,
|
1492
1510
|
"specialty_lighting_schedule": null,
|
1493
1511
|
"exit_lighting_schedule": null,
|
1494
|
-
"target_illuminance_setpoint":
|
1512
|
+
"target_illuminance_setpoint": 125,
|
1513
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1495
1514
|
"psa_nongeometry_fraction": null,
|
1496
1515
|
"ssa_nongeometry_fraction": null,
|
1497
1516
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1572,7 +1591,8 @@
|
|
1572
1591
|
"high_bay_lighting_schedule": null,
|
1573
1592
|
"specialty_lighting_schedule": null,
|
1574
1593
|
"exit_lighting_schedule": null,
|
1575
|
-
"target_illuminance_setpoint":
|
1594
|
+
"target_illuminance_setpoint": 100,
|
1595
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1576
1596
|
"psa_nongeometry_fraction": null,
|
1577
1597
|
"ssa_nongeometry_fraction": null,
|
1578
1598
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1653,7 +1673,8 @@
|
|
1653
1673
|
"high_bay_lighting_schedule": null,
|
1654
1674
|
"specialty_lighting_schedule": null,
|
1655
1675
|
"exit_lighting_schedule": null,
|
1656
|
-
"target_illuminance_setpoint":
|
1676
|
+
"target_illuminance_setpoint": 400,
|
1677
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1657
1678
|
"psa_nongeometry_fraction": null,
|
1658
1679
|
"ssa_nongeometry_fraction": null,
|
1659
1680
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1734,7 +1755,8 @@
|
|
1734
1755
|
"high_bay_lighting_schedule": null,
|
1735
1756
|
"specialty_lighting_schedule": null,
|
1736
1757
|
"exit_lighting_schedule": null,
|
1737
|
-
"target_illuminance_setpoint":
|
1758
|
+
"target_illuminance_setpoint": 250,
|
1759
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1738
1760
|
"psa_nongeometry_fraction": null,
|
1739
1761
|
"ssa_nongeometry_fraction": null,
|
1740
1762
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1815,7 +1837,8 @@
|
|
1815
1837
|
"high_bay_lighting_schedule": null,
|
1816
1838
|
"specialty_lighting_schedule": null,
|
1817
1839
|
"exit_lighting_schedule": null,
|
1818
|
-
"target_illuminance_setpoint":
|
1840
|
+
"target_illuminance_setpoint": 250,
|
1841
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1819
1842
|
"psa_nongeometry_fraction": null,
|
1820
1843
|
"ssa_nongeometry_fraction": null,
|
1821
1844
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1896,7 +1919,8 @@
|
|
1896
1919
|
"high_bay_lighting_schedule": null,
|
1897
1920
|
"specialty_lighting_schedule": null,
|
1898
1921
|
"exit_lighting_schedule": null,
|
1899
|
-
"target_illuminance_setpoint":
|
1922
|
+
"target_illuminance_setpoint": 400,
|
1923
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1900
1924
|
"psa_nongeometry_fraction": null,
|
1901
1925
|
"ssa_nongeometry_fraction": null,
|
1902
1926
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -1977,7 +2001,8 @@
|
|
1977
2001
|
"high_bay_lighting_schedule": null,
|
1978
2002
|
"specialty_lighting_schedule": null,
|
1979
2003
|
"exit_lighting_schedule": null,
|
1980
|
-
"target_illuminance_setpoint":
|
2004
|
+
"target_illuminance_setpoint": 400,
|
2005
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
1981
2006
|
"psa_nongeometry_fraction": null,
|
1982
2007
|
"ssa_nongeometry_fraction": null,
|
1983
2008
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -2058,7 +2083,8 @@
|
|
2058
2083
|
"high_bay_lighting_schedule": null,
|
2059
2084
|
"specialty_lighting_schedule": null,
|
2060
2085
|
"exit_lighting_schedule": null,
|
2061
|
-
"target_illuminance_setpoint":
|
2086
|
+
"target_illuminance_setpoint": 250,
|
2087
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2062
2088
|
"psa_nongeometry_fraction": null,
|
2063
2089
|
"ssa_nongeometry_fraction": null,
|
2064
2090
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -2139,7 +2165,8 @@
|
|
2139
2165
|
"high_bay_lighting_schedule": null,
|
2140
2166
|
"specialty_lighting_schedule": null,
|
2141
2167
|
"exit_lighting_schedule": null,
|
2142
|
-
"target_illuminance_setpoint":
|
2168
|
+
"target_illuminance_setpoint": 450,
|
2169
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2143
2170
|
"psa_nongeometry_fraction": null,
|
2144
2171
|
"ssa_nongeometry_fraction": null,
|
2145
2172
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -2220,7 +2247,8 @@
|
|
2220
2247
|
"high_bay_lighting_schedule": null,
|
2221
2248
|
"specialty_lighting_schedule": null,
|
2222
2249
|
"exit_lighting_schedule": null,
|
2223
|
-
"target_illuminance_setpoint":
|
2250
|
+
"target_illuminance_setpoint": 400,
|
2251
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2224
2252
|
"psa_nongeometry_fraction": null,
|
2225
2253
|
"ssa_nongeometry_fraction": null,
|
2226
2254
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -2301,7 +2329,8 @@
|
|
2301
2329
|
"high_bay_lighting_schedule": null,
|
2302
2330
|
"specialty_lighting_schedule": null,
|
2303
2331
|
"exit_lighting_schedule": null,
|
2304
|
-
"target_illuminance_setpoint":
|
2332
|
+
"target_illuminance_setpoint": 400,
|
2333
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2305
2334
|
"psa_nongeometry_fraction": null,
|
2306
2335
|
"ssa_nongeometry_fraction": null,
|
2307
2336
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -2382,7 +2411,8 @@
|
|
2382
2411
|
"high_bay_lighting_schedule": null,
|
2383
2412
|
"specialty_lighting_schedule": null,
|
2384
2413
|
"exit_lighting_schedule": null,
|
2385
|
-
"target_illuminance_setpoint":
|
2414
|
+
"target_illuminance_setpoint": 75,
|
2415
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2386
2416
|
"psa_nongeometry_fraction": null,
|
2387
2417
|
"ssa_nongeometry_fraction": null,
|
2388
2418
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -2463,7 +2493,8 @@
|
|
2463
2493
|
"high_bay_lighting_schedule": null,
|
2464
2494
|
"specialty_lighting_schedule": null,
|
2465
2495
|
"exit_lighting_schedule": null,
|
2466
|
-
"target_illuminance_setpoint":
|
2496
|
+
"target_illuminance_setpoint": 400,
|
2497
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2467
2498
|
"psa_nongeometry_fraction": null,
|
2468
2499
|
"ssa_nongeometry_fraction": null,
|
2469
2500
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -2544,7 +2575,8 @@
|
|
2544
2575
|
"high_bay_lighting_schedule": null,
|
2545
2576
|
"specialty_lighting_schedule": null,
|
2546
2577
|
"exit_lighting_schedule": null,
|
2547
|
-
"target_illuminance_setpoint":
|
2578
|
+
"target_illuminance_setpoint": 225,
|
2579
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2548
2580
|
"psa_nongeometry_fraction": null,
|
2549
2581
|
"ssa_nongeometry_fraction": null,
|
2550
2582
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -2625,7 +2657,8 @@
|
|
2625
2657
|
"high_bay_lighting_schedule": null,
|
2626
2658
|
"specialty_lighting_schedule": null,
|
2627
2659
|
"exit_lighting_schedule": null,
|
2628
|
-
"target_illuminance_setpoint":
|
2660
|
+
"target_illuminance_setpoint": 150,
|
2661
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2629
2662
|
"psa_nongeometry_fraction": null,
|
2630
2663
|
"ssa_nongeometry_fraction": null,
|
2631
2664
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -2706,7 +2739,8 @@
|
|
2706
2739
|
"high_bay_lighting_schedule": null,
|
2707
2740
|
"specialty_lighting_schedule": null,
|
2708
2741
|
"exit_lighting_schedule": null,
|
2709
|
-
"target_illuminance_setpoint":
|
2742
|
+
"target_illuminance_setpoint": 500,
|
2743
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2710
2744
|
"psa_nongeometry_fraction": null,
|
2711
2745
|
"ssa_nongeometry_fraction": null,
|
2712
2746
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -2787,7 +2821,8 @@
|
|
2787
2821
|
"high_bay_lighting_schedule": null,
|
2788
2822
|
"specialty_lighting_schedule": null,
|
2789
2823
|
"exit_lighting_schedule": null,
|
2790
|
-
"target_illuminance_setpoint":
|
2824
|
+
"target_illuminance_setpoint": 250,
|
2825
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2791
2826
|
"psa_nongeometry_fraction": null,
|
2792
2827
|
"ssa_nongeometry_fraction": null,
|
2793
2828
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -2868,7 +2903,8 @@
|
|
2868
2903
|
"high_bay_lighting_schedule": null,
|
2869
2904
|
"specialty_lighting_schedule": null,
|
2870
2905
|
"exit_lighting_schedule": null,
|
2871
|
-
"target_illuminance_setpoint":
|
2906
|
+
"target_illuminance_setpoint": 250,
|
2907
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2872
2908
|
"psa_nongeometry_fraction": null,
|
2873
2909
|
"ssa_nongeometry_fraction": null,
|
2874
2910
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -2949,7 +2985,8 @@
|
|
2949
2985
|
"high_bay_lighting_schedule": null,
|
2950
2986
|
"specialty_lighting_schedule": null,
|
2951
2987
|
"exit_lighting_schedule": null,
|
2952
|
-
"target_illuminance_setpoint":
|
2988
|
+
"target_illuminance_setpoint": 250,
|
2989
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
2953
2990
|
"psa_nongeometry_fraction": null,
|
2954
2991
|
"ssa_nongeometry_fraction": null,
|
2955
2992
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3030,7 +3067,8 @@
|
|
3030
3067
|
"high_bay_lighting_schedule": null,
|
3031
3068
|
"specialty_lighting_schedule": null,
|
3032
3069
|
"exit_lighting_schedule": null,
|
3033
|
-
"target_illuminance_setpoint":
|
3070
|
+
"target_illuminance_setpoint": 250,
|
3071
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3034
3072
|
"psa_nongeometry_fraction": null,
|
3035
3073
|
"ssa_nongeometry_fraction": null,
|
3036
3074
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3111,7 +3149,8 @@
|
|
3111
3149
|
"high_bay_lighting_schedule": null,
|
3112
3150
|
"specialty_lighting_schedule": null,
|
3113
3151
|
"exit_lighting_schedule": null,
|
3114
|
-
"target_illuminance_setpoint":
|
3152
|
+
"target_illuminance_setpoint": 250,
|
3153
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3115
3154
|
"psa_nongeometry_fraction": null,
|
3116
3155
|
"ssa_nongeometry_fraction": null,
|
3117
3156
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3192,7 +3231,8 @@
|
|
3192
3231
|
"high_bay_lighting_schedule": null,
|
3193
3232
|
"specialty_lighting_schedule": null,
|
3194
3233
|
"exit_lighting_schedule": null,
|
3195
|
-
"target_illuminance_setpoint":
|
3234
|
+
"target_illuminance_setpoint": 250,
|
3235
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3196
3236
|
"psa_nongeometry_fraction": null,
|
3197
3237
|
"ssa_nongeometry_fraction": null,
|
3198
3238
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3273,7 +3313,8 @@
|
|
3273
3313
|
"high_bay_lighting_schedule": null,
|
3274
3314
|
"specialty_lighting_schedule": null,
|
3275
3315
|
"exit_lighting_schedule": null,
|
3276
|
-
"target_illuminance_setpoint":
|
3316
|
+
"target_illuminance_setpoint": 250,
|
3317
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3277
3318
|
"psa_nongeometry_fraction": null,
|
3278
3319
|
"ssa_nongeometry_fraction": null,
|
3279
3320
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3354,7 +3395,8 @@
|
|
3354
3395
|
"high_bay_lighting_schedule": null,
|
3355
3396
|
"specialty_lighting_schedule": null,
|
3356
3397
|
"exit_lighting_schedule": null,
|
3357
|
-
"target_illuminance_setpoint":
|
3398
|
+
"target_illuminance_setpoint": 250,
|
3399
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3358
3400
|
"psa_nongeometry_fraction": null,
|
3359
3401
|
"ssa_nongeometry_fraction": null,
|
3360
3402
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3435,7 +3477,8 @@
|
|
3435
3477
|
"high_bay_lighting_schedule": null,
|
3436
3478
|
"specialty_lighting_schedule": null,
|
3437
3479
|
"exit_lighting_schedule": null,
|
3438
|
-
"target_illuminance_setpoint":
|
3480
|
+
"target_illuminance_setpoint": 250,
|
3481
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3439
3482
|
"psa_nongeometry_fraction": null,
|
3440
3483
|
"ssa_nongeometry_fraction": null,
|
3441
3484
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3516,7 +3559,8 @@
|
|
3516
3559
|
"high_bay_lighting_schedule": null,
|
3517
3560
|
"specialty_lighting_schedule": null,
|
3518
3561
|
"exit_lighting_schedule": null,
|
3519
|
-
"target_illuminance_setpoint":
|
3562
|
+
"target_illuminance_setpoint": 250,
|
3563
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3520
3564
|
"psa_nongeometry_fraction": null,
|
3521
3565
|
"ssa_nongeometry_fraction": null,
|
3522
3566
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3597,7 +3641,8 @@
|
|
3597
3641
|
"high_bay_lighting_schedule": null,
|
3598
3642
|
"specialty_lighting_schedule": null,
|
3599
3643
|
"exit_lighting_schedule": null,
|
3600
|
-
"target_illuminance_setpoint":
|
3644
|
+
"target_illuminance_setpoint": 250,
|
3645
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3601
3646
|
"psa_nongeometry_fraction": null,
|
3602
3647
|
"ssa_nongeometry_fraction": null,
|
3603
3648
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3678,7 +3723,8 @@
|
|
3678
3723
|
"high_bay_lighting_schedule": null,
|
3679
3724
|
"specialty_lighting_schedule": null,
|
3680
3725
|
"exit_lighting_schedule": null,
|
3681
|
-
"target_illuminance_setpoint":
|
3726
|
+
"target_illuminance_setpoint": 250,
|
3727
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3682
3728
|
"psa_nongeometry_fraction": null,
|
3683
3729
|
"ssa_nongeometry_fraction": null,
|
3684
3730
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3759,7 +3805,8 @@
|
|
3759
3805
|
"high_bay_lighting_schedule": null,
|
3760
3806
|
"specialty_lighting_schedule": null,
|
3761
3807
|
"exit_lighting_schedule": null,
|
3762
|
-
"target_illuminance_setpoint":
|
3808
|
+
"target_illuminance_setpoint": 250,
|
3809
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3763
3810
|
"psa_nongeometry_fraction": null,
|
3764
3811
|
"ssa_nongeometry_fraction": null,
|
3765
3812
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3840,7 +3887,8 @@
|
|
3840
3887
|
"high_bay_lighting_schedule": null,
|
3841
3888
|
"specialty_lighting_schedule": null,
|
3842
3889
|
"exit_lighting_schedule": null,
|
3843
|
-
"target_illuminance_setpoint":
|
3890
|
+
"target_illuminance_setpoint": 250,
|
3891
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3844
3892
|
"psa_nongeometry_fraction": null,
|
3845
3893
|
"ssa_nongeometry_fraction": null,
|
3846
3894
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -3921,7 +3969,8 @@
|
|
3921
3969
|
"high_bay_lighting_schedule": null,
|
3922
3970
|
"specialty_lighting_schedule": null,
|
3923
3971
|
"exit_lighting_schedule": null,
|
3924
|
-
"target_illuminance_setpoint":
|
3972
|
+
"target_illuminance_setpoint": 250,
|
3973
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
3925
3974
|
"psa_nongeometry_fraction": null,
|
3926
3975
|
"ssa_nongeometry_fraction": null,
|
3927
3976
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4002,7 +4051,8 @@
|
|
4002
4051
|
"high_bay_lighting_schedule": null,
|
4003
4052
|
"specialty_lighting_schedule": null,
|
4004
4053
|
"exit_lighting_schedule": null,
|
4005
|
-
"target_illuminance_setpoint":
|
4054
|
+
"target_illuminance_setpoint": 250,
|
4055
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4006
4056
|
"psa_nongeometry_fraction": null,
|
4007
4057
|
"ssa_nongeometry_fraction": null,
|
4008
4058
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4083,7 +4133,8 @@
|
|
4083
4133
|
"high_bay_lighting_schedule": null,
|
4084
4134
|
"specialty_lighting_schedule": null,
|
4085
4135
|
"exit_lighting_schedule": null,
|
4086
|
-
"target_illuminance_setpoint":
|
4136
|
+
"target_illuminance_setpoint": 250,
|
4137
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4087
4138
|
"psa_nongeometry_fraction": null,
|
4088
4139
|
"ssa_nongeometry_fraction": null,
|
4089
4140
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4164,7 +4215,8 @@
|
|
4164
4215
|
"high_bay_lighting_schedule": null,
|
4165
4216
|
"specialty_lighting_schedule": null,
|
4166
4217
|
"exit_lighting_schedule": null,
|
4167
|
-
"target_illuminance_setpoint":
|
4218
|
+
"target_illuminance_setpoint": 250,
|
4219
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4168
4220
|
"psa_nongeometry_fraction": null,
|
4169
4221
|
"ssa_nongeometry_fraction": null,
|
4170
4222
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4245,7 +4297,8 @@
|
|
4245
4297
|
"high_bay_lighting_schedule": null,
|
4246
4298
|
"specialty_lighting_schedule": null,
|
4247
4299
|
"exit_lighting_schedule": null,
|
4248
|
-
"target_illuminance_setpoint":
|
4300
|
+
"target_illuminance_setpoint": 250,
|
4301
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4249
4302
|
"psa_nongeometry_fraction": null,
|
4250
4303
|
"ssa_nongeometry_fraction": null,
|
4251
4304
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4326,7 +4379,8 @@
|
|
4326
4379
|
"high_bay_lighting_schedule": null,
|
4327
4380
|
"specialty_lighting_schedule": null,
|
4328
4381
|
"exit_lighting_schedule": null,
|
4329
|
-
"target_illuminance_setpoint":
|
4382
|
+
"target_illuminance_setpoint": 250,
|
4383
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4330
4384
|
"psa_nongeometry_fraction": null,
|
4331
4385
|
"ssa_nongeometry_fraction": null,
|
4332
4386
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4407,7 +4461,8 @@
|
|
4407
4461
|
"high_bay_lighting_schedule": null,
|
4408
4462
|
"specialty_lighting_schedule": null,
|
4409
4463
|
"exit_lighting_schedule": null,
|
4410
|
-
"target_illuminance_setpoint":
|
4464
|
+
"target_illuminance_setpoint": 250,
|
4465
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4411
4466
|
"psa_nongeometry_fraction": null,
|
4412
4467
|
"ssa_nongeometry_fraction": null,
|
4413
4468
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4488,7 +4543,8 @@
|
|
4488
4543
|
"high_bay_lighting_schedule": null,
|
4489
4544
|
"specialty_lighting_schedule": null,
|
4490
4545
|
"exit_lighting_schedule": null,
|
4491
|
-
"target_illuminance_setpoint":
|
4546
|
+
"target_illuminance_setpoint": 250,
|
4547
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4492
4548
|
"psa_nongeometry_fraction": null,
|
4493
4549
|
"ssa_nongeometry_fraction": null,
|
4494
4550
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4569,7 +4625,8 @@
|
|
4569
4625
|
"high_bay_lighting_schedule": null,
|
4570
4626
|
"specialty_lighting_schedule": null,
|
4571
4627
|
"exit_lighting_schedule": null,
|
4572
|
-
"target_illuminance_setpoint":
|
4628
|
+
"target_illuminance_setpoint": 250,
|
4629
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4573
4630
|
"psa_nongeometry_fraction": null,
|
4574
4631
|
"ssa_nongeometry_fraction": null,
|
4575
4632
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4650,7 +4707,8 @@
|
|
4650
4707
|
"high_bay_lighting_schedule": null,
|
4651
4708
|
"specialty_lighting_schedule": null,
|
4652
4709
|
"exit_lighting_schedule": null,
|
4653
|
-
"target_illuminance_setpoint":
|
4710
|
+
"target_illuminance_setpoint": 250,
|
4711
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4654
4712
|
"psa_nongeometry_fraction": null,
|
4655
4713
|
"ssa_nongeometry_fraction": null,
|
4656
4714
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4731,7 +4789,8 @@
|
|
4731
4789
|
"high_bay_lighting_schedule": null,
|
4732
4790
|
"specialty_lighting_schedule": null,
|
4733
4791
|
"exit_lighting_schedule": null,
|
4734
|
-
"target_illuminance_setpoint":
|
4792
|
+
"target_illuminance_setpoint": 250,
|
4793
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4735
4794
|
"psa_nongeometry_fraction": null,
|
4736
4795
|
"ssa_nongeometry_fraction": null,
|
4737
4796
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4812,7 +4871,8 @@
|
|
4812
4871
|
"high_bay_lighting_schedule": null,
|
4813
4872
|
"specialty_lighting_schedule": null,
|
4814
4873
|
"exit_lighting_schedule": null,
|
4815
|
-
"target_illuminance_setpoint":
|
4874
|
+
"target_illuminance_setpoint": 250,
|
4875
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4816
4876
|
"psa_nongeometry_fraction": null,
|
4817
4877
|
"ssa_nongeometry_fraction": null,
|
4818
4878
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4893,7 +4953,8 @@
|
|
4893
4953
|
"high_bay_lighting_schedule": null,
|
4894
4954
|
"specialty_lighting_schedule": null,
|
4895
4955
|
"exit_lighting_schedule": null,
|
4896
|
-
"target_illuminance_setpoint":
|
4956
|
+
"target_illuminance_setpoint": 250,
|
4957
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4897
4958
|
"psa_nongeometry_fraction": null,
|
4898
4959
|
"ssa_nongeometry_fraction": null,
|
4899
4960
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -4974,7 +5035,8 @@
|
|
4974
5035
|
"high_bay_lighting_schedule": null,
|
4975
5036
|
"specialty_lighting_schedule": null,
|
4976
5037
|
"exit_lighting_schedule": null,
|
4977
|
-
"target_illuminance_setpoint":
|
5038
|
+
"target_illuminance_setpoint": 250,
|
5039
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
4978
5040
|
"psa_nongeometry_fraction": null,
|
4979
5041
|
"ssa_nongeometry_fraction": null,
|
4980
5042
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5055,7 +5117,8 @@
|
|
5055
5117
|
"high_bay_lighting_schedule": null,
|
5056
5118
|
"specialty_lighting_schedule": null,
|
5057
5119
|
"exit_lighting_schedule": null,
|
5058
|
-
"target_illuminance_setpoint":
|
5120
|
+
"target_illuminance_setpoint": 250,
|
5121
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5059
5122
|
"psa_nongeometry_fraction": null,
|
5060
5123
|
"ssa_nongeometry_fraction": null,
|
5061
5124
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5136,7 +5199,8 @@
|
|
5136
5199
|
"high_bay_lighting_schedule": null,
|
5137
5200
|
"specialty_lighting_schedule": null,
|
5138
5201
|
"exit_lighting_schedule": null,
|
5139
|
-
"target_illuminance_setpoint":
|
5202
|
+
"target_illuminance_setpoint": 250,
|
5203
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5140
5204
|
"psa_nongeometry_fraction": null,
|
5141
5205
|
"ssa_nongeometry_fraction": null,
|
5142
5206
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5217,7 +5281,8 @@
|
|
5217
5281
|
"high_bay_lighting_schedule": null,
|
5218
5282
|
"specialty_lighting_schedule": null,
|
5219
5283
|
"exit_lighting_schedule": null,
|
5220
|
-
"target_illuminance_setpoint":
|
5284
|
+
"target_illuminance_setpoint": 250,
|
5285
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5221
5286
|
"psa_nongeometry_fraction": null,
|
5222
5287
|
"ssa_nongeometry_fraction": null,
|
5223
5288
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5298,7 +5363,8 @@
|
|
5298
5363
|
"high_bay_lighting_schedule": null,
|
5299
5364
|
"specialty_lighting_schedule": null,
|
5300
5365
|
"exit_lighting_schedule": null,
|
5301
|
-
"target_illuminance_setpoint":
|
5366
|
+
"target_illuminance_setpoint": 250,
|
5367
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5302
5368
|
"psa_nongeometry_fraction": null,
|
5303
5369
|
"ssa_nongeometry_fraction": null,
|
5304
5370
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5379,7 +5445,8 @@
|
|
5379
5445
|
"high_bay_lighting_schedule": null,
|
5380
5446
|
"specialty_lighting_schedule": null,
|
5381
5447
|
"exit_lighting_schedule": null,
|
5382
|
-
"target_illuminance_setpoint":
|
5448
|
+
"target_illuminance_setpoint": 250,
|
5449
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5383
5450
|
"psa_nongeometry_fraction": null,
|
5384
5451
|
"ssa_nongeometry_fraction": null,
|
5385
5452
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5460,7 +5527,8 @@
|
|
5460
5527
|
"high_bay_lighting_schedule": null,
|
5461
5528
|
"specialty_lighting_schedule": null,
|
5462
5529
|
"exit_lighting_schedule": null,
|
5463
|
-
"target_illuminance_setpoint":
|
5530
|
+
"target_illuminance_setpoint": 100,
|
5531
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5464
5532
|
"psa_nongeometry_fraction": null,
|
5465
5533
|
"ssa_nongeometry_fraction": null,
|
5466
5534
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5541,7 +5609,8 @@
|
|
5541
5609
|
"high_bay_lighting_schedule": null,
|
5542
5610
|
"specialty_lighting_schedule": null,
|
5543
5611
|
"exit_lighting_schedule": null,
|
5544
|
-
"target_illuminance_setpoint":
|
5612
|
+
"target_illuminance_setpoint": 350,
|
5613
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5545
5614
|
"psa_nongeometry_fraction": null,
|
5546
5615
|
"ssa_nongeometry_fraction": null,
|
5547
5616
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5622,7 +5691,8 @@
|
|
5622
5691
|
"high_bay_lighting_schedule": null,
|
5623
5692
|
"specialty_lighting_schedule": null,
|
5624
5693
|
"exit_lighting_schedule": null,
|
5625
|
-
"target_illuminance_setpoint":
|
5694
|
+
"target_illuminance_setpoint": 350,
|
5695
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5626
5696
|
"psa_nongeometry_fraction": null,
|
5627
5697
|
"ssa_nongeometry_fraction": null,
|
5628
5698
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5703,7 +5773,8 @@
|
|
5703
5773
|
"high_bay_lighting_schedule": null,
|
5704
5774
|
"specialty_lighting_schedule": null,
|
5705
5775
|
"exit_lighting_schedule": null,
|
5706
|
-
"target_illuminance_setpoint":
|
5776
|
+
"target_illuminance_setpoint": 250,
|
5777
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5707
5778
|
"psa_nongeometry_fraction": null,
|
5708
5779
|
"ssa_nongeometry_fraction": null,
|
5709
5780
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5784,7 +5855,8 @@
|
|
5784
5855
|
"high_bay_lighting_schedule": null,
|
5785
5856
|
"specialty_lighting_schedule": null,
|
5786
5857
|
"exit_lighting_schedule": null,
|
5787
|
-
"target_illuminance_setpoint":
|
5858
|
+
"target_illuminance_setpoint": 250,
|
5859
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5788
5860
|
"psa_nongeometry_fraction": null,
|
5789
5861
|
"ssa_nongeometry_fraction": null,
|
5790
5862
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5865,7 +5937,8 @@
|
|
5865
5937
|
"high_bay_lighting_schedule": null,
|
5866
5938
|
"specialty_lighting_schedule": null,
|
5867
5939
|
"exit_lighting_schedule": null,
|
5868
|
-
"target_illuminance_setpoint":
|
5940
|
+
"target_illuminance_setpoint": 250,
|
5941
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5869
5942
|
"psa_nongeometry_fraction": null,
|
5870
5943
|
"ssa_nongeometry_fraction": null,
|
5871
5944
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -5946,7 +6019,8 @@
|
|
5946
6019
|
"high_bay_lighting_schedule": null,
|
5947
6020
|
"specialty_lighting_schedule": null,
|
5948
6021
|
"exit_lighting_schedule": null,
|
5949
|
-
"target_illuminance_setpoint":
|
6022
|
+
"target_illuminance_setpoint": 150,
|
6023
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
5950
6024
|
"psa_nongeometry_fraction": null,
|
5951
6025
|
"ssa_nongeometry_fraction": null,
|
5952
6026
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6027,7 +6101,8 @@
|
|
6027
6101
|
"high_bay_lighting_schedule": null,
|
6028
6102
|
"specialty_lighting_schedule": null,
|
6029
6103
|
"exit_lighting_schedule": null,
|
6030
|
-
"target_illuminance_setpoint":
|
6104
|
+
"target_illuminance_setpoint": 150,
|
6105
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6031
6106
|
"psa_nongeometry_fraction": null,
|
6032
6107
|
"ssa_nongeometry_fraction": null,
|
6033
6108
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6108,7 +6183,8 @@
|
|
6108
6183
|
"high_bay_lighting_schedule": null,
|
6109
6184
|
"specialty_lighting_schedule": null,
|
6110
6185
|
"exit_lighting_schedule": null,
|
6111
|
-
"target_illuminance_setpoint":
|
6186
|
+
"target_illuminance_setpoint": 100,
|
6187
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6112
6188
|
"psa_nongeometry_fraction": null,
|
6113
6189
|
"ssa_nongeometry_fraction": null,
|
6114
6190
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6189,7 +6265,8 @@
|
|
6189
6265
|
"high_bay_lighting_schedule": null,
|
6190
6266
|
"specialty_lighting_schedule": null,
|
6191
6267
|
"exit_lighting_schedule": null,
|
6192
|
-
"target_illuminance_setpoint":
|
6268
|
+
"target_illuminance_setpoint": 100,
|
6269
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6193
6270
|
"psa_nongeometry_fraction": null,
|
6194
6271
|
"ssa_nongeometry_fraction": null,
|
6195
6272
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6270,7 +6347,8 @@
|
|
6270
6347
|
"high_bay_lighting_schedule": null,
|
6271
6348
|
"specialty_lighting_schedule": null,
|
6272
6349
|
"exit_lighting_schedule": null,
|
6273
|
-
"target_illuminance_setpoint":
|
6350
|
+
"target_illuminance_setpoint": 100,
|
6351
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6274
6352
|
"psa_nongeometry_fraction": null,
|
6275
6353
|
"ssa_nongeometry_fraction": null,
|
6276
6354
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6351,7 +6429,8 @@
|
|
6351
6429
|
"high_bay_lighting_schedule": null,
|
6352
6430
|
"specialty_lighting_schedule": null,
|
6353
6431
|
"exit_lighting_schedule": null,
|
6354
|
-
"target_illuminance_setpoint":
|
6432
|
+
"target_illuminance_setpoint": 100,
|
6433
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6355
6434
|
"psa_nongeometry_fraction": null,
|
6356
6435
|
"ssa_nongeometry_fraction": null,
|
6357
6436
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6432,7 +6511,8 @@
|
|
6432
6511
|
"high_bay_lighting_schedule": null,
|
6433
6512
|
"specialty_lighting_schedule": null,
|
6434
6513
|
"exit_lighting_schedule": null,
|
6435
|
-
"target_illuminance_setpoint":
|
6514
|
+
"target_illuminance_setpoint": 100,
|
6515
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6436
6516
|
"psa_nongeometry_fraction": null,
|
6437
6517
|
"ssa_nongeometry_fraction": null,
|
6438
6518
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6513,7 +6593,8 @@
|
|
6513
6593
|
"high_bay_lighting_schedule": null,
|
6514
6594
|
"specialty_lighting_schedule": null,
|
6515
6595
|
"exit_lighting_schedule": null,
|
6516
|
-
"target_illuminance_setpoint":
|
6596
|
+
"target_illuminance_setpoint": 100,
|
6597
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6517
6598
|
"psa_nongeometry_fraction": null,
|
6518
6599
|
"ssa_nongeometry_fraction": null,
|
6519
6600
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6594,7 +6675,8 @@
|
|
6594
6675
|
"high_bay_lighting_schedule": null,
|
6595
6676
|
"specialty_lighting_schedule": null,
|
6596
6677
|
"exit_lighting_schedule": null,
|
6597
|
-
"target_illuminance_setpoint":
|
6678
|
+
"target_illuminance_setpoint": 100,
|
6679
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6598
6680
|
"psa_nongeometry_fraction": null,
|
6599
6681
|
"ssa_nongeometry_fraction": null,
|
6600
6682
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6675,7 +6757,8 @@
|
|
6675
6757
|
"high_bay_lighting_schedule": null,
|
6676
6758
|
"specialty_lighting_schedule": null,
|
6677
6759
|
"exit_lighting_schedule": null,
|
6678
|
-
"target_illuminance_setpoint":
|
6760
|
+
"target_illuminance_setpoint": 100,
|
6761
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6679
6762
|
"psa_nongeometry_fraction": null,
|
6680
6763
|
"ssa_nongeometry_fraction": null,
|
6681
6764
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6756,7 +6839,8 @@
|
|
6756
6839
|
"high_bay_lighting_schedule": null,
|
6757
6840
|
"specialty_lighting_schedule": null,
|
6758
6841
|
"exit_lighting_schedule": null,
|
6759
|
-
"target_illuminance_setpoint":
|
6842
|
+
"target_illuminance_setpoint": 100,
|
6843
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6760
6844
|
"psa_nongeometry_fraction": null,
|
6761
6845
|
"ssa_nongeometry_fraction": null,
|
6762
6846
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6837,7 +6921,8 @@
|
|
6837
6921
|
"high_bay_lighting_schedule": null,
|
6838
6922
|
"specialty_lighting_schedule": null,
|
6839
6923
|
"exit_lighting_schedule": null,
|
6840
|
-
"target_illuminance_setpoint":
|
6924
|
+
"target_illuminance_setpoint": 100,
|
6925
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6841
6926
|
"psa_nongeometry_fraction": null,
|
6842
6927
|
"ssa_nongeometry_fraction": null,
|
6843
6928
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6918,7 +7003,8 @@
|
|
6918
7003
|
"high_bay_lighting_schedule": null,
|
6919
7004
|
"specialty_lighting_schedule": null,
|
6920
7005
|
"exit_lighting_schedule": null,
|
6921
|
-
"target_illuminance_setpoint":
|
7006
|
+
"target_illuminance_setpoint": 100,
|
7007
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
6922
7008
|
"psa_nongeometry_fraction": null,
|
6923
7009
|
"ssa_nongeometry_fraction": null,
|
6924
7010
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -6999,7 +7085,8 @@
|
|
6999
7085
|
"high_bay_lighting_schedule": null,
|
7000
7086
|
"specialty_lighting_schedule": null,
|
7001
7087
|
"exit_lighting_schedule": null,
|
7002
|
-
"target_illuminance_setpoint":
|
7088
|
+
"target_illuminance_setpoint": 400,
|
7089
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7003
7090
|
"psa_nongeometry_fraction": null,
|
7004
7091
|
"ssa_nongeometry_fraction": null,
|
7005
7092
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7080,7 +7167,8 @@
|
|
7080
7167
|
"high_bay_lighting_schedule": null,
|
7081
7168
|
"specialty_lighting_schedule": null,
|
7082
7169
|
"exit_lighting_schedule": null,
|
7083
|
-
"target_illuminance_setpoint":
|
7170
|
+
"target_illuminance_setpoint": 400,
|
7171
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7084
7172
|
"psa_nongeometry_fraction": null,
|
7085
7173
|
"ssa_nongeometry_fraction": null,
|
7086
7174
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7161,7 +7249,8 @@
|
|
7161
7249
|
"high_bay_lighting_schedule": null,
|
7162
7250
|
"specialty_lighting_schedule": null,
|
7163
7251
|
"exit_lighting_schedule": null,
|
7164
|
-
"target_illuminance_setpoint":
|
7252
|
+
"target_illuminance_setpoint": 400,
|
7253
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7165
7254
|
"psa_nongeometry_fraction": null,
|
7166
7255
|
"ssa_nongeometry_fraction": null,
|
7167
7256
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7242,7 +7331,8 @@
|
|
7242
7331
|
"high_bay_lighting_schedule": null,
|
7243
7332
|
"specialty_lighting_schedule": null,
|
7244
7333
|
"exit_lighting_schedule": null,
|
7245
|
-
"target_illuminance_setpoint":
|
7334
|
+
"target_illuminance_setpoint": 350,
|
7335
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7246
7336
|
"psa_nongeometry_fraction": null,
|
7247
7337
|
"ssa_nongeometry_fraction": null,
|
7248
7338
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7323,7 +7413,8 @@
|
|
7323
7413
|
"high_bay_lighting_schedule": null,
|
7324
7414
|
"specialty_lighting_schedule": null,
|
7325
7415
|
"exit_lighting_schedule": null,
|
7326
|
-
"target_illuminance_setpoint":
|
7416
|
+
"target_illuminance_setpoint": 350,
|
7417
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7327
7418
|
"psa_nongeometry_fraction": null,
|
7328
7419
|
"ssa_nongeometry_fraction": null,
|
7329
7420
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7404,7 +7495,8 @@
|
|
7404
7495
|
"high_bay_lighting_schedule": null,
|
7405
7496
|
"specialty_lighting_schedule": null,
|
7406
7497
|
"exit_lighting_schedule": null,
|
7407
|
-
"target_illuminance_setpoint":
|
7498
|
+
"target_illuminance_setpoint": 350,
|
7499
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7408
7500
|
"psa_nongeometry_fraction": null,
|
7409
7501
|
"ssa_nongeometry_fraction": null,
|
7410
7502
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7485,7 +7577,8 @@
|
|
7485
7577
|
"high_bay_lighting_schedule": null,
|
7486
7578
|
"specialty_lighting_schedule": null,
|
7487
7579
|
"exit_lighting_schedule": null,
|
7488
|
-
"target_illuminance_setpoint":
|
7580
|
+
"target_illuminance_setpoint": 350,
|
7581
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7489
7582
|
"psa_nongeometry_fraction": null,
|
7490
7583
|
"ssa_nongeometry_fraction": null,
|
7491
7584
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7566,7 +7659,8 @@
|
|
7566
7659
|
"high_bay_lighting_schedule": null,
|
7567
7660
|
"specialty_lighting_schedule": null,
|
7568
7661
|
"exit_lighting_schedule": null,
|
7569
|
-
"target_illuminance_setpoint":
|
7662
|
+
"target_illuminance_setpoint": 350,
|
7663
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7570
7664
|
"psa_nongeometry_fraction": null,
|
7571
7665
|
"ssa_nongeometry_fraction": null,
|
7572
7666
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7647,7 +7741,8 @@
|
|
7647
7741
|
"high_bay_lighting_schedule": null,
|
7648
7742
|
"specialty_lighting_schedule": null,
|
7649
7743
|
"exit_lighting_schedule": null,
|
7650
|
-
"target_illuminance_setpoint":
|
7744
|
+
"target_illuminance_setpoint": 350,
|
7745
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7651
7746
|
"psa_nongeometry_fraction": null,
|
7652
7747
|
"ssa_nongeometry_fraction": null,
|
7653
7748
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7728,7 +7823,8 @@
|
|
7728
7823
|
"high_bay_lighting_schedule": null,
|
7729
7824
|
"specialty_lighting_schedule": null,
|
7730
7825
|
"exit_lighting_schedule": null,
|
7731
|
-
"target_illuminance_setpoint":
|
7826
|
+
"target_illuminance_setpoint": 350,
|
7827
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7732
7828
|
"psa_nongeometry_fraction": null,
|
7733
7829
|
"ssa_nongeometry_fraction": null,
|
7734
7830
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7809,7 +7905,8 @@
|
|
7809
7905
|
"high_bay_lighting_schedule": null,
|
7810
7906
|
"specialty_lighting_schedule": null,
|
7811
7907
|
"exit_lighting_schedule": null,
|
7812
|
-
"target_illuminance_setpoint":
|
7908
|
+
"target_illuminance_setpoint": 350,
|
7909
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7813
7910
|
"psa_nongeometry_fraction": null,
|
7814
7911
|
"ssa_nongeometry_fraction": null,
|
7815
7912
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7890,7 +7987,8 @@
|
|
7890
7987
|
"high_bay_lighting_schedule": null,
|
7891
7988
|
"specialty_lighting_schedule": null,
|
7892
7989
|
"exit_lighting_schedule": null,
|
7893
|
-
"target_illuminance_setpoint":
|
7990
|
+
"target_illuminance_setpoint": 350,
|
7991
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7894
7992
|
"psa_nongeometry_fraction": null,
|
7895
7993
|
"ssa_nongeometry_fraction": null,
|
7896
7994
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -7971,7 +8069,8 @@
|
|
7971
8069
|
"high_bay_lighting_schedule": null,
|
7972
8070
|
"specialty_lighting_schedule": null,
|
7973
8071
|
"exit_lighting_schedule": null,
|
7974
|
-
"target_illuminance_setpoint":
|
8072
|
+
"target_illuminance_setpoint": 350,
|
8073
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
7975
8074
|
"psa_nongeometry_fraction": null,
|
7976
8075
|
"ssa_nongeometry_fraction": null,
|
7977
8076
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -8052,7 +8151,8 @@
|
|
8052
8151
|
"high_bay_lighting_schedule": null,
|
8053
8152
|
"specialty_lighting_schedule": null,
|
8054
8153
|
"exit_lighting_schedule": null,
|
8055
|
-
"target_illuminance_setpoint":
|
8154
|
+
"target_illuminance_setpoint": 350,
|
8155
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8056
8156
|
"psa_nongeometry_fraction": null,
|
8057
8157
|
"ssa_nongeometry_fraction": null,
|
8058
8158
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -8133,7 +8233,8 @@
|
|
8133
8233
|
"high_bay_lighting_schedule": null,
|
8134
8234
|
"specialty_lighting_schedule": null,
|
8135
8235
|
"exit_lighting_schedule": null,
|
8136
|
-
"target_illuminance_setpoint":
|
8236
|
+
"target_illuminance_setpoint": 350,
|
8237
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8137
8238
|
"psa_nongeometry_fraction": null,
|
8138
8239
|
"ssa_nongeometry_fraction": null,
|
8139
8240
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -8214,7 +8315,8 @@
|
|
8214
8315
|
"high_bay_lighting_schedule": null,
|
8215
8316
|
"specialty_lighting_schedule": null,
|
8216
8317
|
"exit_lighting_schedule": null,
|
8217
|
-
"target_illuminance_setpoint":
|
8318
|
+
"target_illuminance_setpoint": 400,
|
8319
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8218
8320
|
"psa_nongeometry_fraction": null,
|
8219
8321
|
"ssa_nongeometry_fraction": null,
|
8220
8322
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -8295,7 +8397,8 @@
|
|
8295
8397
|
"high_bay_lighting_schedule": null,
|
8296
8398
|
"specialty_lighting_schedule": null,
|
8297
8399
|
"exit_lighting_schedule": null,
|
8298
|
-
"target_illuminance_setpoint":
|
8400
|
+
"target_illuminance_setpoint": 400,
|
8401
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8299
8402
|
"psa_nongeometry_fraction": null,
|
8300
8403
|
"ssa_nongeometry_fraction": null,
|
8301
8404
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -8376,7 +8479,8 @@
|
|
8376
8479
|
"high_bay_lighting_schedule": null,
|
8377
8480
|
"specialty_lighting_schedule": null,
|
8378
8481
|
"exit_lighting_schedule": null,
|
8379
|
-
"target_illuminance_setpoint":
|
8482
|
+
"target_illuminance_setpoint": 150,
|
8483
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8380
8484
|
"psa_nongeometry_fraction": null,
|
8381
8485
|
"ssa_nongeometry_fraction": null,
|
8382
8486
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -8457,7 +8561,8 @@
|
|
8457
8561
|
"high_bay_lighting_schedule": null,
|
8458
8562
|
"specialty_lighting_schedule": null,
|
8459
8563
|
"exit_lighting_schedule": null,
|
8460
|
-
"target_illuminance_setpoint":
|
8564
|
+
"target_illuminance_setpoint": 150,
|
8565
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8461
8566
|
"psa_nongeometry_fraction": null,
|
8462
8567
|
"ssa_nongeometry_fraction": null,
|
8463
8568
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -8538,7 +8643,8 @@
|
|
8538
8643
|
"high_bay_lighting_schedule": null,
|
8539
8644
|
"specialty_lighting_schedule": null,
|
8540
8645
|
"exit_lighting_schedule": null,
|
8541
|
-
"target_illuminance_setpoint":
|
8646
|
+
"target_illuminance_setpoint": 150,
|
8647
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8542
8648
|
"psa_nongeometry_fraction": null,
|
8543
8649
|
"ssa_nongeometry_fraction": null,
|
8544
8650
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -8619,7 +8725,8 @@
|
|
8619
8725
|
"high_bay_lighting_schedule": null,
|
8620
8726
|
"specialty_lighting_schedule": null,
|
8621
8727
|
"exit_lighting_schedule": null,
|
8622
|
-
"target_illuminance_setpoint":
|
8728
|
+
"target_illuminance_setpoint": 150,
|
8729
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8623
8730
|
"psa_nongeometry_fraction": null,
|
8624
8731
|
"ssa_nongeometry_fraction": null,
|
8625
8732
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -8700,7 +8807,8 @@
|
|
8700
8807
|
"high_bay_lighting_schedule": null,
|
8701
8808
|
"specialty_lighting_schedule": null,
|
8702
8809
|
"exit_lighting_schedule": null,
|
8703
|
-
"target_illuminance_setpoint":
|
8810
|
+
"target_illuminance_setpoint": 150,
|
8811
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8704
8812
|
"psa_nongeometry_fraction": null,
|
8705
8813
|
"ssa_nongeometry_fraction": null,
|
8706
8814
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -8781,7 +8889,8 @@
|
|
8781
8889
|
"high_bay_lighting_schedule": null,
|
8782
8890
|
"specialty_lighting_schedule": null,
|
8783
8891
|
"exit_lighting_schedule": null,
|
8784
|
-
"target_illuminance_setpoint":
|
8892
|
+
"target_illuminance_setpoint": 150,
|
8893
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8785
8894
|
"psa_nongeometry_fraction": null,
|
8786
8895
|
"ssa_nongeometry_fraction": null,
|
8787
8896
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -8862,7 +8971,8 @@
|
|
8862
8971
|
"high_bay_lighting_schedule": null,
|
8863
8972
|
"specialty_lighting_schedule": null,
|
8864
8973
|
"exit_lighting_schedule": null,
|
8865
|
-
"target_illuminance_setpoint":
|
8974
|
+
"target_illuminance_setpoint": 150,
|
8975
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8866
8976
|
"psa_nongeometry_fraction": null,
|
8867
8977
|
"ssa_nongeometry_fraction": null,
|
8868
8978
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -8943,7 +9053,8 @@
|
|
8943
9053
|
"high_bay_lighting_schedule": null,
|
8944
9054
|
"specialty_lighting_schedule": null,
|
8945
9055
|
"exit_lighting_schedule": null,
|
8946
|
-
"target_illuminance_setpoint":
|
9056
|
+
"target_illuminance_setpoint": 150,
|
9057
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
8947
9058
|
"psa_nongeometry_fraction": null,
|
8948
9059
|
"ssa_nongeometry_fraction": null,
|
8949
9060
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9024,7 +9135,8 @@
|
|
9024
9135
|
"high_bay_lighting_schedule": null,
|
9025
9136
|
"specialty_lighting_schedule": null,
|
9026
9137
|
"exit_lighting_schedule": null,
|
9027
|
-
"target_illuminance_setpoint":
|
9138
|
+
"target_illuminance_setpoint": 150,
|
9139
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9028
9140
|
"psa_nongeometry_fraction": null,
|
9029
9141
|
"ssa_nongeometry_fraction": null,
|
9030
9142
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9105,7 +9217,8 @@
|
|
9105
9217
|
"high_bay_lighting_schedule": null,
|
9106
9218
|
"specialty_lighting_schedule": null,
|
9107
9219
|
"exit_lighting_schedule": null,
|
9108
|
-
"target_illuminance_setpoint":
|
9220
|
+
"target_illuminance_setpoint": 150,
|
9221
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9109
9222
|
"psa_nongeometry_fraction": null,
|
9110
9223
|
"ssa_nongeometry_fraction": null,
|
9111
9224
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9186,7 +9299,8 @@
|
|
9186
9299
|
"high_bay_lighting_schedule": null,
|
9187
9300
|
"specialty_lighting_schedule": null,
|
9188
9301
|
"exit_lighting_schedule": null,
|
9189
|
-
"target_illuminance_setpoint":
|
9302
|
+
"target_illuminance_setpoint": 150,
|
9303
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9190
9304
|
"psa_nongeometry_fraction": null,
|
9191
9305
|
"ssa_nongeometry_fraction": null,
|
9192
9306
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9267,7 +9381,8 @@
|
|
9267
9381
|
"high_bay_lighting_schedule": null,
|
9268
9382
|
"specialty_lighting_schedule": null,
|
9269
9383
|
"exit_lighting_schedule": null,
|
9270
|
-
"target_illuminance_setpoint":
|
9384
|
+
"target_illuminance_setpoint": 150,
|
9385
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9271
9386
|
"psa_nongeometry_fraction": null,
|
9272
9387
|
"ssa_nongeometry_fraction": null,
|
9273
9388
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9348,7 +9463,8 @@
|
|
9348
9463
|
"high_bay_lighting_schedule": null,
|
9349
9464
|
"specialty_lighting_schedule": null,
|
9350
9465
|
"exit_lighting_schedule": null,
|
9351
|
-
"target_illuminance_setpoint":
|
9466
|
+
"target_illuminance_setpoint": 150,
|
9467
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9352
9468
|
"psa_nongeometry_fraction": null,
|
9353
9469
|
"ssa_nongeometry_fraction": null,
|
9354
9470
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9429,7 +9545,8 @@
|
|
9429
9545
|
"high_bay_lighting_schedule": null,
|
9430
9546
|
"specialty_lighting_schedule": null,
|
9431
9547
|
"exit_lighting_schedule": null,
|
9432
|
-
"target_illuminance_setpoint":
|
9548
|
+
"target_illuminance_setpoint": 150,
|
9549
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9433
9550
|
"psa_nongeometry_fraction": null,
|
9434
9551
|
"ssa_nongeometry_fraction": null,
|
9435
9552
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9510,7 +9627,8 @@
|
|
9510
9627
|
"high_bay_lighting_schedule": null,
|
9511
9628
|
"specialty_lighting_schedule": null,
|
9512
9629
|
"exit_lighting_schedule": null,
|
9513
|
-
"target_illuminance_setpoint":
|
9630
|
+
"target_illuminance_setpoint": 150,
|
9631
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9514
9632
|
"psa_nongeometry_fraction": null,
|
9515
9633
|
"ssa_nongeometry_fraction": null,
|
9516
9634
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9591,7 +9709,8 @@
|
|
9591
9709
|
"high_bay_lighting_schedule": null,
|
9592
9710
|
"specialty_lighting_schedule": null,
|
9593
9711
|
"exit_lighting_schedule": null,
|
9594
|
-
"target_illuminance_setpoint":
|
9712
|
+
"target_illuminance_setpoint": 150,
|
9713
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9595
9714
|
"psa_nongeometry_fraction": null,
|
9596
9715
|
"ssa_nongeometry_fraction": null,
|
9597
9716
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9672,7 +9791,8 @@
|
|
9672
9791
|
"high_bay_lighting_schedule": null,
|
9673
9792
|
"specialty_lighting_schedule": null,
|
9674
9793
|
"exit_lighting_schedule": null,
|
9675
|
-
"target_illuminance_setpoint":
|
9794
|
+
"target_illuminance_setpoint": 150,
|
9795
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9676
9796
|
"psa_nongeometry_fraction": null,
|
9677
9797
|
"ssa_nongeometry_fraction": null,
|
9678
9798
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9753,7 +9873,8 @@
|
|
9753
9873
|
"high_bay_lighting_schedule": null,
|
9754
9874
|
"specialty_lighting_schedule": null,
|
9755
9875
|
"exit_lighting_schedule": null,
|
9756
|
-
"target_illuminance_setpoint":
|
9876
|
+
"target_illuminance_setpoint": 150,
|
9877
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9757
9878
|
"psa_nongeometry_fraction": null,
|
9758
9879
|
"ssa_nongeometry_fraction": null,
|
9759
9880
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9834,7 +9955,8 @@
|
|
9834
9955
|
"high_bay_lighting_schedule": null,
|
9835
9956
|
"specialty_lighting_schedule": null,
|
9836
9957
|
"exit_lighting_schedule": null,
|
9837
|
-
"target_illuminance_setpoint":
|
9958
|
+
"target_illuminance_setpoint": 150,
|
9959
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9838
9960
|
"psa_nongeometry_fraction": null,
|
9839
9961
|
"ssa_nongeometry_fraction": null,
|
9840
9962
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9915,7 +10037,8 @@
|
|
9915
10037
|
"high_bay_lighting_schedule": null,
|
9916
10038
|
"specialty_lighting_schedule": null,
|
9917
10039
|
"exit_lighting_schedule": null,
|
9918
|
-
"target_illuminance_setpoint":
|
10040
|
+
"target_illuminance_setpoint": 150,
|
10041
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
9919
10042
|
"psa_nongeometry_fraction": null,
|
9920
10043
|
"ssa_nongeometry_fraction": null,
|
9921
10044
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -9996,7 +10119,8 @@
|
|
9996
10119
|
"high_bay_lighting_schedule": null,
|
9997
10120
|
"specialty_lighting_schedule": null,
|
9998
10121
|
"exit_lighting_schedule": null,
|
9999
|
-
"target_illuminance_setpoint":
|
10122
|
+
"target_illuminance_setpoint": 150,
|
10123
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10000
10124
|
"psa_nongeometry_fraction": null,
|
10001
10125
|
"ssa_nongeometry_fraction": null,
|
10002
10126
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10077,7 +10201,8 @@
|
|
10077
10201
|
"high_bay_lighting_schedule": null,
|
10078
10202
|
"specialty_lighting_schedule": null,
|
10079
10203
|
"exit_lighting_schedule": null,
|
10080
|
-
"target_illuminance_setpoint":
|
10204
|
+
"target_illuminance_setpoint": 150,
|
10205
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10081
10206
|
"psa_nongeometry_fraction": null,
|
10082
10207
|
"ssa_nongeometry_fraction": null,
|
10083
10208
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10158,7 +10283,8 @@
|
|
10158
10283
|
"high_bay_lighting_schedule": null,
|
10159
10284
|
"specialty_lighting_schedule": null,
|
10160
10285
|
"exit_lighting_schedule": null,
|
10161
|
-
"target_illuminance_setpoint":
|
10286
|
+
"target_illuminance_setpoint": 150,
|
10287
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10162
10288
|
"psa_nongeometry_fraction": null,
|
10163
10289
|
"ssa_nongeometry_fraction": null,
|
10164
10290
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10239,7 +10365,8 @@
|
|
10239
10365
|
"high_bay_lighting_schedule": null,
|
10240
10366
|
"specialty_lighting_schedule": null,
|
10241
10367
|
"exit_lighting_schedule": null,
|
10242
|
-
"target_illuminance_setpoint":
|
10368
|
+
"target_illuminance_setpoint": 150,
|
10369
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10243
10370
|
"psa_nongeometry_fraction": null,
|
10244
10371
|
"ssa_nongeometry_fraction": null,
|
10245
10372
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10320,7 +10447,8 @@
|
|
10320
10447
|
"high_bay_lighting_schedule": null,
|
10321
10448
|
"specialty_lighting_schedule": null,
|
10322
10449
|
"exit_lighting_schedule": null,
|
10323
|
-
"target_illuminance_setpoint":
|
10450
|
+
"target_illuminance_setpoint": 150,
|
10451
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10324
10452
|
"psa_nongeometry_fraction": null,
|
10325
10453
|
"ssa_nongeometry_fraction": null,
|
10326
10454
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10401,7 +10529,8 @@
|
|
10401
10529
|
"high_bay_lighting_schedule": null,
|
10402
10530
|
"specialty_lighting_schedule": null,
|
10403
10531
|
"exit_lighting_schedule": null,
|
10404
|
-
"target_illuminance_setpoint":
|
10532
|
+
"target_illuminance_setpoint": 150,
|
10533
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10405
10534
|
"psa_nongeometry_fraction": null,
|
10406
10535
|
"ssa_nongeometry_fraction": null,
|
10407
10536
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10482,7 +10611,8 @@
|
|
10482
10611
|
"high_bay_lighting_schedule": null,
|
10483
10612
|
"specialty_lighting_schedule": null,
|
10484
10613
|
"exit_lighting_schedule": null,
|
10485
|
-
"target_illuminance_setpoint":
|
10614
|
+
"target_illuminance_setpoint": 150,
|
10615
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10486
10616
|
"psa_nongeometry_fraction": null,
|
10487
10617
|
"ssa_nongeometry_fraction": null,
|
10488
10618
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10563,7 +10693,8 @@
|
|
10563
10693
|
"high_bay_lighting_schedule": null,
|
10564
10694
|
"specialty_lighting_schedule": null,
|
10565
10695
|
"exit_lighting_schedule": null,
|
10566
|
-
"target_illuminance_setpoint":
|
10696
|
+
"target_illuminance_setpoint": 150,
|
10697
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10567
10698
|
"psa_nongeometry_fraction": null,
|
10568
10699
|
"ssa_nongeometry_fraction": null,
|
10569
10700
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10644,7 +10775,8 @@
|
|
10644
10775
|
"high_bay_lighting_schedule": null,
|
10645
10776
|
"specialty_lighting_schedule": null,
|
10646
10777
|
"exit_lighting_schedule": null,
|
10647
|
-
"target_illuminance_setpoint":
|
10778
|
+
"target_illuminance_setpoint": 150,
|
10779
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10648
10780
|
"psa_nongeometry_fraction": null,
|
10649
10781
|
"ssa_nongeometry_fraction": null,
|
10650
10782
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10725,7 +10857,8 @@
|
|
10725
10857
|
"high_bay_lighting_schedule": null,
|
10726
10858
|
"specialty_lighting_schedule": null,
|
10727
10859
|
"exit_lighting_schedule": null,
|
10728
|
-
"target_illuminance_setpoint":
|
10860
|
+
"target_illuminance_setpoint": 150,
|
10861
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10729
10862
|
"psa_nongeometry_fraction": null,
|
10730
10863
|
"ssa_nongeometry_fraction": null,
|
10731
10864
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10806,7 +10939,8 @@
|
|
10806
10939
|
"high_bay_lighting_schedule": null,
|
10807
10940
|
"specialty_lighting_schedule": null,
|
10808
10941
|
"exit_lighting_schedule": null,
|
10809
|
-
"target_illuminance_setpoint":
|
10942
|
+
"target_illuminance_setpoint": 150,
|
10943
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10810
10944
|
"psa_nongeometry_fraction": null,
|
10811
10945
|
"ssa_nongeometry_fraction": null,
|
10812
10946
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10887,7 +11021,8 @@
|
|
10887
11021
|
"high_bay_lighting_schedule": null,
|
10888
11022
|
"specialty_lighting_schedule": null,
|
10889
11023
|
"exit_lighting_schedule": null,
|
10890
|
-
"target_illuminance_setpoint":
|
11024
|
+
"target_illuminance_setpoint": 150,
|
11025
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10891
11026
|
"psa_nongeometry_fraction": null,
|
10892
11027
|
"ssa_nongeometry_fraction": null,
|
10893
11028
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -10968,7 +11103,8 @@
|
|
10968
11103
|
"high_bay_lighting_schedule": null,
|
10969
11104
|
"specialty_lighting_schedule": null,
|
10970
11105
|
"exit_lighting_schedule": null,
|
10971
|
-
"target_illuminance_setpoint":
|
11106
|
+
"target_illuminance_setpoint": 150,
|
11107
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
10972
11108
|
"psa_nongeometry_fraction": null,
|
10973
11109
|
"ssa_nongeometry_fraction": null,
|
10974
11110
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11049,7 +11185,8 @@
|
|
11049
11185
|
"high_bay_lighting_schedule": null,
|
11050
11186
|
"specialty_lighting_schedule": null,
|
11051
11187
|
"exit_lighting_schedule": null,
|
11052
|
-
"target_illuminance_setpoint":
|
11188
|
+
"target_illuminance_setpoint": 150,
|
11189
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11053
11190
|
"psa_nongeometry_fraction": null,
|
11054
11191
|
"ssa_nongeometry_fraction": null,
|
11055
11192
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11130,7 +11267,8 @@
|
|
11130
11267
|
"high_bay_lighting_schedule": null,
|
11131
11268
|
"specialty_lighting_schedule": null,
|
11132
11269
|
"exit_lighting_schedule": null,
|
11133
|
-
"target_illuminance_setpoint":
|
11270
|
+
"target_illuminance_setpoint": 150,
|
11271
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11134
11272
|
"psa_nongeometry_fraction": null,
|
11135
11273
|
"ssa_nongeometry_fraction": null,
|
11136
11274
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11211,7 +11349,8 @@
|
|
11211
11349
|
"high_bay_lighting_schedule": null,
|
11212
11350
|
"specialty_lighting_schedule": null,
|
11213
11351
|
"exit_lighting_schedule": null,
|
11214
|
-
"target_illuminance_setpoint":
|
11352
|
+
"target_illuminance_setpoint": 150,
|
11353
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11215
11354
|
"psa_nongeometry_fraction": null,
|
11216
11355
|
"ssa_nongeometry_fraction": null,
|
11217
11356
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11292,7 +11431,8 @@
|
|
11292
11431
|
"high_bay_lighting_schedule": null,
|
11293
11432
|
"specialty_lighting_schedule": null,
|
11294
11433
|
"exit_lighting_schedule": null,
|
11295
|
-
"target_illuminance_setpoint":
|
11434
|
+
"target_illuminance_setpoint": 150,
|
11435
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11296
11436
|
"psa_nongeometry_fraction": null,
|
11297
11437
|
"ssa_nongeometry_fraction": null,
|
11298
11438
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11373,7 +11513,8 @@
|
|
11373
11513
|
"high_bay_lighting_schedule": null,
|
11374
11514
|
"specialty_lighting_schedule": null,
|
11375
11515
|
"exit_lighting_schedule": null,
|
11376
|
-
"target_illuminance_setpoint":
|
11516
|
+
"target_illuminance_setpoint": 150,
|
11517
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11377
11518
|
"psa_nongeometry_fraction": null,
|
11378
11519
|
"ssa_nongeometry_fraction": null,
|
11379
11520
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11454,7 +11595,8 @@
|
|
11454
11595
|
"high_bay_lighting_schedule": null,
|
11455
11596
|
"specialty_lighting_schedule": null,
|
11456
11597
|
"exit_lighting_schedule": null,
|
11457
|
-
"target_illuminance_setpoint":
|
11598
|
+
"target_illuminance_setpoint": 150,
|
11599
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11458
11600
|
"psa_nongeometry_fraction": null,
|
11459
11601
|
"ssa_nongeometry_fraction": null,
|
11460
11602
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11535,7 +11677,8 @@
|
|
11535
11677
|
"high_bay_lighting_schedule": null,
|
11536
11678
|
"specialty_lighting_schedule": null,
|
11537
11679
|
"exit_lighting_schedule": null,
|
11538
|
-
"target_illuminance_setpoint":
|
11680
|
+
"target_illuminance_setpoint": 150,
|
11681
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11539
11682
|
"psa_nongeometry_fraction": null,
|
11540
11683
|
"ssa_nongeometry_fraction": null,
|
11541
11684
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11616,7 +11759,8 @@
|
|
11616
11759
|
"high_bay_lighting_schedule": null,
|
11617
11760
|
"specialty_lighting_schedule": null,
|
11618
11761
|
"exit_lighting_schedule": null,
|
11619
|
-
"target_illuminance_setpoint":
|
11762
|
+
"target_illuminance_setpoint": 150,
|
11763
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11620
11764
|
"psa_nongeometry_fraction": null,
|
11621
11765
|
"ssa_nongeometry_fraction": null,
|
11622
11766
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11697,7 +11841,8 @@
|
|
11697
11841
|
"high_bay_lighting_schedule": null,
|
11698
11842
|
"specialty_lighting_schedule": null,
|
11699
11843
|
"exit_lighting_schedule": null,
|
11700
|
-
"target_illuminance_setpoint":
|
11844
|
+
"target_illuminance_setpoint": 150,
|
11845
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11701
11846
|
"psa_nongeometry_fraction": null,
|
11702
11847
|
"ssa_nongeometry_fraction": null,
|
11703
11848
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11778,7 +11923,8 @@
|
|
11778
11923
|
"high_bay_lighting_schedule": null,
|
11779
11924
|
"specialty_lighting_schedule": null,
|
11780
11925
|
"exit_lighting_schedule": null,
|
11781
|
-
"target_illuminance_setpoint":
|
11926
|
+
"target_illuminance_setpoint": 150,
|
11927
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11782
11928
|
"psa_nongeometry_fraction": null,
|
11783
11929
|
"ssa_nongeometry_fraction": null,
|
11784
11930
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11859,7 +12005,8 @@
|
|
11859
12005
|
"high_bay_lighting_schedule": null,
|
11860
12006
|
"specialty_lighting_schedule": null,
|
11861
12007
|
"exit_lighting_schedule": null,
|
11862
|
-
"target_illuminance_setpoint":
|
12008
|
+
"target_illuminance_setpoint": 150,
|
12009
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11863
12010
|
"psa_nongeometry_fraction": null,
|
11864
12011
|
"ssa_nongeometry_fraction": null,
|
11865
12012
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -11940,7 +12087,8 @@
|
|
11940
12087
|
"high_bay_lighting_schedule": null,
|
11941
12088
|
"specialty_lighting_schedule": null,
|
11942
12089
|
"exit_lighting_schedule": null,
|
11943
|
-
"target_illuminance_setpoint":
|
12090
|
+
"target_illuminance_setpoint": 400,
|
12091
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
11944
12092
|
"psa_nongeometry_fraction": null,
|
11945
12093
|
"ssa_nongeometry_fraction": null,
|
11946
12094
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12021,7 +12169,8 @@
|
|
12021
12169
|
"high_bay_lighting_schedule": null,
|
12022
12170
|
"specialty_lighting_schedule": null,
|
12023
12171
|
"exit_lighting_schedule": null,
|
12024
|
-
"target_illuminance_setpoint":
|
12172
|
+
"target_illuminance_setpoint": 100,
|
12173
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12025
12174
|
"psa_nongeometry_fraction": null,
|
12026
12175
|
"ssa_nongeometry_fraction": null,
|
12027
12176
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12102,7 +12251,8 @@
|
|
12102
12251
|
"high_bay_lighting_schedule": null,
|
12103
12252
|
"specialty_lighting_schedule": null,
|
12104
12253
|
"exit_lighting_schedule": null,
|
12105
|
-
"target_illuminance_setpoint":
|
12254
|
+
"target_illuminance_setpoint": 200,
|
12255
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12106
12256
|
"psa_nongeometry_fraction": null,
|
12107
12257
|
"ssa_nongeometry_fraction": null,
|
12108
12258
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12183,7 +12333,8 @@
|
|
12183
12333
|
"high_bay_lighting_schedule": null,
|
12184
12334
|
"specialty_lighting_schedule": null,
|
12185
12335
|
"exit_lighting_schedule": null,
|
12186
|
-
"target_illuminance_setpoint":
|
12336
|
+
"target_illuminance_setpoint": 200,
|
12337
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12187
12338
|
"psa_nongeometry_fraction": null,
|
12188
12339
|
"ssa_nongeometry_fraction": null,
|
12189
12340
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12264,7 +12415,8 @@
|
|
12264
12415
|
"high_bay_lighting_schedule": null,
|
12265
12416
|
"specialty_lighting_schedule": null,
|
12266
12417
|
"exit_lighting_schedule": null,
|
12267
|
-
"target_illuminance_setpoint":
|
12418
|
+
"target_illuminance_setpoint": 200,
|
12419
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12268
12420
|
"psa_nongeometry_fraction": null,
|
12269
12421
|
"ssa_nongeometry_fraction": null,
|
12270
12422
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12345,7 +12497,8 @@
|
|
12345
12497
|
"high_bay_lighting_schedule": null,
|
12346
12498
|
"specialty_lighting_schedule": null,
|
12347
12499
|
"exit_lighting_schedule": null,
|
12348
|
-
"target_illuminance_setpoint":
|
12500
|
+
"target_illuminance_setpoint": 200,
|
12501
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12349
12502
|
"psa_nongeometry_fraction": null,
|
12350
12503
|
"ssa_nongeometry_fraction": null,
|
12351
12504
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12426,7 +12579,8 @@
|
|
12426
12579
|
"high_bay_lighting_schedule": null,
|
12427
12580
|
"specialty_lighting_schedule": null,
|
12428
12581
|
"exit_lighting_schedule": null,
|
12429
|
-
"target_illuminance_setpoint":
|
12582
|
+
"target_illuminance_setpoint": 200,
|
12583
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12430
12584
|
"psa_nongeometry_fraction": null,
|
12431
12585
|
"ssa_nongeometry_fraction": null,
|
12432
12586
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12507,7 +12661,8 @@
|
|
12507
12661
|
"high_bay_lighting_schedule": null,
|
12508
12662
|
"specialty_lighting_schedule": null,
|
12509
12663
|
"exit_lighting_schedule": null,
|
12510
|
-
"target_illuminance_setpoint":
|
12664
|
+
"target_illuminance_setpoint": 250,
|
12665
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12511
12666
|
"psa_nongeometry_fraction": null,
|
12512
12667
|
"ssa_nongeometry_fraction": null,
|
12513
12668
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -12588,7 +12743,8 @@
|
|
12588
12743
|
"high_bay_lighting_schedule": null,
|
12589
12744
|
"specialty_lighting_schedule": null,
|
12590
12745
|
"exit_lighting_schedule": null,
|
12591
|
-
"target_illuminance_setpoint":
|
12746
|
+
"target_illuminance_setpoint": 350,
|
12747
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12592
12748
|
"psa_nongeometry_fraction": null,
|
12593
12749
|
"ssa_nongeometry_fraction": null,
|
12594
12750
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12669,7 +12825,8 @@
|
|
12669
12825
|
"high_bay_lighting_schedule": null,
|
12670
12826
|
"specialty_lighting_schedule": null,
|
12671
12827
|
"exit_lighting_schedule": null,
|
12672
|
-
"target_illuminance_setpoint":
|
12828
|
+
"target_illuminance_setpoint": 350,
|
12829
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12673
12830
|
"psa_nongeometry_fraction": null,
|
12674
12831
|
"ssa_nongeometry_fraction": null,
|
12675
12832
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12750,7 +12907,8 @@
|
|
12750
12907
|
"high_bay_lighting_schedule": null,
|
12751
12908
|
"specialty_lighting_schedule": null,
|
12752
12909
|
"exit_lighting_schedule": null,
|
12753
|
-
"target_illuminance_setpoint":
|
12910
|
+
"target_illuminance_setpoint": 350,
|
12911
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12754
12912
|
"psa_nongeometry_fraction": null,
|
12755
12913
|
"ssa_nongeometry_fraction": null,
|
12756
12914
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12831,7 +12989,8 @@
|
|
12831
12989
|
"high_bay_lighting_schedule": null,
|
12832
12990
|
"specialty_lighting_schedule": null,
|
12833
12991
|
"exit_lighting_schedule": null,
|
12834
|
-
"target_illuminance_setpoint":
|
12992
|
+
"target_illuminance_setpoint": 350,
|
12993
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12835
12994
|
"psa_nongeometry_fraction": null,
|
12836
12995
|
"ssa_nongeometry_fraction": null,
|
12837
12996
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12912,7 +13071,8 @@
|
|
12912
13071
|
"high_bay_lighting_schedule": null,
|
12913
13072
|
"specialty_lighting_schedule": null,
|
12914
13073
|
"exit_lighting_schedule": null,
|
12915
|
-
"target_illuminance_setpoint":
|
13074
|
+
"target_illuminance_setpoint": 350,
|
13075
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12916
13076
|
"psa_nongeometry_fraction": null,
|
12917
13077
|
"ssa_nongeometry_fraction": null,
|
12918
13078
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -12993,7 +13153,8 @@
|
|
12993
13153
|
"high_bay_lighting_schedule": null,
|
12994
13154
|
"specialty_lighting_schedule": null,
|
12995
13155
|
"exit_lighting_schedule": null,
|
12996
|
-
"target_illuminance_setpoint":
|
13156
|
+
"target_illuminance_setpoint": 350,
|
13157
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
12997
13158
|
"psa_nongeometry_fraction": null,
|
12998
13159
|
"ssa_nongeometry_fraction": null,
|
12999
13160
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -13074,7 +13235,8 @@
|
|
13074
13235
|
"high_bay_lighting_schedule": null,
|
13075
13236
|
"specialty_lighting_schedule": null,
|
13076
13237
|
"exit_lighting_schedule": null,
|
13077
|
-
"target_illuminance_setpoint":
|
13238
|
+
"target_illuminance_setpoint": 350,
|
13239
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13078
13240
|
"psa_nongeometry_fraction": null,
|
13079
13241
|
"ssa_nongeometry_fraction": null,
|
13080
13242
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -13155,7 +13317,8 @@
|
|
13155
13317
|
"high_bay_lighting_schedule": null,
|
13156
13318
|
"specialty_lighting_schedule": null,
|
13157
13319
|
"exit_lighting_schedule": null,
|
13158
|
-
"target_illuminance_setpoint":
|
13320
|
+
"target_illuminance_setpoint": 350,
|
13321
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13159
13322
|
"psa_nongeometry_fraction": null,
|
13160
13323
|
"ssa_nongeometry_fraction": null,
|
13161
13324
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -13236,7 +13399,8 @@
|
|
13236
13399
|
"high_bay_lighting_schedule": null,
|
13237
13400
|
"specialty_lighting_schedule": null,
|
13238
13401
|
"exit_lighting_schedule": null,
|
13239
|
-
"target_illuminance_setpoint":
|
13402
|
+
"target_illuminance_setpoint": 350,
|
13403
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13240
13404
|
"psa_nongeometry_fraction": null,
|
13241
13405
|
"ssa_nongeometry_fraction": null,
|
13242
13406
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -13317,7 +13481,8 @@
|
|
13317
13481
|
"high_bay_lighting_schedule": null,
|
13318
13482
|
"specialty_lighting_schedule": null,
|
13319
13483
|
"exit_lighting_schedule": null,
|
13320
|
-
"target_illuminance_setpoint":
|
13484
|
+
"target_illuminance_setpoint": 350,
|
13485
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13321
13486
|
"psa_nongeometry_fraction": null,
|
13322
13487
|
"ssa_nongeometry_fraction": null,
|
13323
13488
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -13398,7 +13563,8 @@
|
|
13398
13563
|
"high_bay_lighting_schedule": null,
|
13399
13564
|
"specialty_lighting_schedule": null,
|
13400
13565
|
"exit_lighting_schedule": null,
|
13401
|
-
"target_illuminance_setpoint":
|
13566
|
+
"target_illuminance_setpoint": 350,
|
13567
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13402
13568
|
"psa_nongeometry_fraction": null,
|
13403
13569
|
"ssa_nongeometry_fraction": null,
|
13404
13570
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -13479,7 +13645,8 @@
|
|
13479
13645
|
"high_bay_lighting_schedule": null,
|
13480
13646
|
"specialty_lighting_schedule": null,
|
13481
13647
|
"exit_lighting_schedule": null,
|
13482
|
-
"target_illuminance_setpoint":
|
13648
|
+
"target_illuminance_setpoint": 350,
|
13649
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13483
13650
|
"psa_nongeometry_fraction": null,
|
13484
13651
|
"ssa_nongeometry_fraction": null,
|
13485
13652
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -13560,7 +13727,8 @@
|
|
13560
13727
|
"high_bay_lighting_schedule": null,
|
13561
13728
|
"specialty_lighting_schedule": null,
|
13562
13729
|
"exit_lighting_schedule": null,
|
13563
|
-
"target_illuminance_setpoint":
|
13730
|
+
"target_illuminance_setpoint": 500,
|
13731
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13564
13732
|
"psa_nongeometry_fraction": null,
|
13565
13733
|
"ssa_nongeometry_fraction": null,
|
13566
13734
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -13641,7 +13809,8 @@
|
|
13641
13809
|
"high_bay_lighting_schedule": null,
|
13642
13810
|
"specialty_lighting_schedule": null,
|
13643
13811
|
"exit_lighting_schedule": null,
|
13644
|
-
"target_illuminance_setpoint":
|
13812
|
+
"target_illuminance_setpoint": 200,
|
13813
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13645
13814
|
"psa_nongeometry_fraction": null,
|
13646
13815
|
"ssa_nongeometry_fraction": null,
|
13647
13816
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -13722,7 +13891,8 @@
|
|
13722
13891
|
"high_bay_lighting_schedule": null,
|
13723
13892
|
"specialty_lighting_schedule": null,
|
13724
13893
|
"exit_lighting_schedule": null,
|
13725
|
-
"target_illuminance_setpoint":
|
13894
|
+
"target_illuminance_setpoint": 500,
|
13895
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13726
13896
|
"psa_nongeometry_fraction": null,
|
13727
13897
|
"ssa_nongeometry_fraction": null,
|
13728
13898
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -13803,7 +13973,8 @@
|
|
13803
13973
|
"high_bay_lighting_schedule": null,
|
13804
13974
|
"specialty_lighting_schedule": null,
|
13805
13975
|
"exit_lighting_schedule": null,
|
13806
|
-
"target_illuminance_setpoint":
|
13976
|
+
"target_illuminance_setpoint": 650,
|
13977
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13807
13978
|
"psa_nongeometry_fraction": null,
|
13808
13979
|
"ssa_nongeometry_fraction": null,
|
13809
13980
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -13884,7 +14055,8 @@
|
|
13884
14055
|
"high_bay_lighting_schedule": null,
|
13885
14056
|
"specialty_lighting_schedule": null,
|
13886
14057
|
"exit_lighting_schedule": null,
|
13887
|
-
"target_illuminance_setpoint":
|
14058
|
+
"target_illuminance_setpoint": 350,
|
14059
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13888
14060
|
"psa_nongeometry_fraction": null,
|
13889
14061
|
"ssa_nongeometry_fraction": null,
|
13890
14062
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -13965,7 +14137,8 @@
|
|
13965
14137
|
"high_bay_lighting_schedule": null,
|
13966
14138
|
"specialty_lighting_schedule": null,
|
13967
14139
|
"exit_lighting_schedule": null,
|
13968
|
-
"target_illuminance_setpoint":
|
14140
|
+
"target_illuminance_setpoint": 200,
|
14141
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
13969
14142
|
"psa_nongeometry_fraction": null,
|
13970
14143
|
"ssa_nongeometry_fraction": null,
|
13971
14144
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -14046,7 +14219,8 @@
|
|
14046
14219
|
"high_bay_lighting_schedule": null,
|
14047
14220
|
"specialty_lighting_schedule": null,
|
14048
14221
|
"exit_lighting_schedule": null,
|
14049
|
-
"target_illuminance_setpoint":
|
14222
|
+
"target_illuminance_setpoint": 200,
|
14223
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14050
14224
|
"psa_nongeometry_fraction": null,
|
14051
14225
|
"ssa_nongeometry_fraction": null,
|
14052
14226
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -14127,7 +14301,8 @@
|
|
14127
14301
|
"high_bay_lighting_schedule": null,
|
14128
14302
|
"specialty_lighting_schedule": null,
|
14129
14303
|
"exit_lighting_schedule": null,
|
14130
|
-
"target_illuminance_setpoint":
|
14304
|
+
"target_illuminance_setpoint": 250,
|
14305
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14131
14306
|
"psa_nongeometry_fraction": null,
|
14132
14307
|
"ssa_nongeometry_fraction": null,
|
14133
14308
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -14208,7 +14383,8 @@
|
|
14208
14383
|
"high_bay_lighting_schedule": null,
|
14209
14384
|
"specialty_lighting_schedule": null,
|
14210
14385
|
"exit_lighting_schedule": null,
|
14211
|
-
"target_illuminance_setpoint":
|
14386
|
+
"target_illuminance_setpoint": 150,
|
14387
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14212
14388
|
"psa_nongeometry_fraction": null,
|
14213
14389
|
"ssa_nongeometry_fraction": null,
|
14214
14390
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -14289,7 +14465,8 @@
|
|
14289
14465
|
"high_bay_lighting_schedule": null,
|
14290
14466
|
"specialty_lighting_schedule": null,
|
14291
14467
|
"exit_lighting_schedule": null,
|
14292
|
-
"target_illuminance_setpoint":
|
14468
|
+
"target_illuminance_setpoint": 200,
|
14469
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14293
14470
|
"psa_nongeometry_fraction": null,
|
14294
14471
|
"ssa_nongeometry_fraction": null,
|
14295
14472
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -14370,7 +14547,8 @@
|
|
14370
14547
|
"high_bay_lighting_schedule": null,
|
14371
14548
|
"specialty_lighting_schedule": null,
|
14372
14549
|
"exit_lighting_schedule": null,
|
14373
|
-
"target_illuminance_setpoint":
|
14550
|
+
"target_illuminance_setpoint": 150,
|
14551
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14374
14552
|
"psa_nongeometry_fraction": null,
|
14375
14553
|
"ssa_nongeometry_fraction": null,
|
14376
14554
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -14451,7 +14629,8 @@
|
|
14451
14629
|
"high_bay_lighting_schedule": null,
|
14452
14630
|
"specialty_lighting_schedule": null,
|
14453
14631
|
"exit_lighting_schedule": null,
|
14454
|
-
"target_illuminance_setpoint":
|
14632
|
+
"target_illuminance_setpoint": 150,
|
14633
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14455
14634
|
"psa_nongeometry_fraction": null,
|
14456
14635
|
"ssa_nongeometry_fraction": null,
|
14457
14636
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -14532,7 +14711,8 @@
|
|
14532
14711
|
"high_bay_lighting_schedule": null,
|
14533
14712
|
"specialty_lighting_schedule": null,
|
14534
14713
|
"exit_lighting_schedule": null,
|
14535
|
-
"target_illuminance_setpoint":
|
14714
|
+
"target_illuminance_setpoint": 100,
|
14715
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14536
14716
|
"psa_nongeometry_fraction": null,
|
14537
14717
|
"ssa_nongeometry_fraction": null,
|
14538
14718
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -14613,7 +14793,8 @@
|
|
14613
14793
|
"high_bay_lighting_schedule": null,
|
14614
14794
|
"specialty_lighting_schedule": null,
|
14615
14795
|
"exit_lighting_schedule": null,
|
14616
|
-
"target_illuminance_setpoint":
|
14796
|
+
"target_illuminance_setpoint": 100,
|
14797
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14617
14798
|
"psa_nongeometry_fraction": null,
|
14618
14799
|
"ssa_nongeometry_fraction": null,
|
14619
14800
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -14694,7 +14875,8 @@
|
|
14694
14875
|
"high_bay_lighting_schedule": null,
|
14695
14876
|
"specialty_lighting_schedule": null,
|
14696
14877
|
"exit_lighting_schedule": null,
|
14697
|
-
"target_illuminance_setpoint":
|
14878
|
+
"target_illuminance_setpoint": 100,
|
14879
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14698
14880
|
"psa_nongeometry_fraction": null,
|
14699
14881
|
"ssa_nongeometry_fraction": null,
|
14700
14882
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -14775,7 +14957,8 @@
|
|
14775
14957
|
"high_bay_lighting_schedule": null,
|
14776
14958
|
"specialty_lighting_schedule": null,
|
14777
14959
|
"exit_lighting_schedule": null,
|
14778
|
-
"target_illuminance_setpoint":
|
14960
|
+
"target_illuminance_setpoint": 100,
|
14961
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14779
14962
|
"psa_nongeometry_fraction": null,
|
14780
14963
|
"ssa_nongeometry_fraction": null,
|
14781
14964
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -14856,7 +15039,8 @@
|
|
14856
15039
|
"high_bay_lighting_schedule": null,
|
14857
15040
|
"specialty_lighting_schedule": null,
|
14858
15041
|
"exit_lighting_schedule": null,
|
14859
|
-
"target_illuminance_setpoint":
|
15042
|
+
"target_illuminance_setpoint": 100,
|
15043
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14860
15044
|
"psa_nongeometry_fraction": null,
|
14861
15045
|
"ssa_nongeometry_fraction": null,
|
14862
15046
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -14937,7 +15121,8 @@
|
|
14937
15121
|
"high_bay_lighting_schedule": null,
|
14938
15122
|
"specialty_lighting_schedule": null,
|
14939
15123
|
"exit_lighting_schedule": null,
|
14940
|
-
"target_illuminance_setpoint":
|
15124
|
+
"target_illuminance_setpoint": 100,
|
15125
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
14941
15126
|
"psa_nongeometry_fraction": null,
|
14942
15127
|
"ssa_nongeometry_fraction": null,
|
14943
15128
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -15018,7 +15203,8 @@
|
|
15018
15203
|
"high_bay_lighting_schedule": null,
|
15019
15204
|
"specialty_lighting_schedule": null,
|
15020
15205
|
"exit_lighting_schedule": null,
|
15021
|
-
"target_illuminance_setpoint":
|
15206
|
+
"target_illuminance_setpoint": 100,
|
15207
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15022
15208
|
"psa_nongeometry_fraction": null,
|
15023
15209
|
"ssa_nongeometry_fraction": null,
|
15024
15210
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -15099,7 +15285,8 @@
|
|
15099
15285
|
"high_bay_lighting_schedule": null,
|
15100
15286
|
"specialty_lighting_schedule": null,
|
15101
15287
|
"exit_lighting_schedule": null,
|
15102
|
-
"target_illuminance_setpoint":
|
15288
|
+
"target_illuminance_setpoint": 100,
|
15289
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15103
15290
|
"psa_nongeometry_fraction": null,
|
15104
15291
|
"ssa_nongeometry_fraction": null,
|
15105
15292
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -15180,7 +15367,8 @@
|
|
15180
15367
|
"high_bay_lighting_schedule": null,
|
15181
15368
|
"specialty_lighting_schedule": null,
|
15182
15369
|
"exit_lighting_schedule": null,
|
15183
|
-
"target_illuminance_setpoint":
|
15370
|
+
"target_illuminance_setpoint": 100,
|
15371
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15184
15372
|
"psa_nongeometry_fraction": null,
|
15185
15373
|
"ssa_nongeometry_fraction": null,
|
15186
15374
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -15261,7 +15449,8 @@
|
|
15261
15449
|
"high_bay_lighting_schedule": null,
|
15262
15450
|
"specialty_lighting_schedule": null,
|
15263
15451
|
"exit_lighting_schedule": null,
|
15264
|
-
"target_illuminance_setpoint":
|
15452
|
+
"target_illuminance_setpoint": 100,
|
15453
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15265
15454
|
"psa_nongeometry_fraction": null,
|
15266
15455
|
"ssa_nongeometry_fraction": null,
|
15267
15456
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -15342,7 +15531,8 @@
|
|
15342
15531
|
"high_bay_lighting_schedule": null,
|
15343
15532
|
"specialty_lighting_schedule": null,
|
15344
15533
|
"exit_lighting_schedule": null,
|
15345
|
-
"target_illuminance_setpoint":
|
15534
|
+
"target_illuminance_setpoint": 100,
|
15535
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15346
15536
|
"psa_nongeometry_fraction": null,
|
15347
15537
|
"ssa_nongeometry_fraction": null,
|
15348
15538
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -15423,7 +15613,8 @@
|
|
15423
15613
|
"high_bay_lighting_schedule": null,
|
15424
15614
|
"specialty_lighting_schedule": null,
|
15425
15615
|
"exit_lighting_schedule": null,
|
15426
|
-
"target_illuminance_setpoint":
|
15616
|
+
"target_illuminance_setpoint": 150,
|
15617
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15427
15618
|
"psa_nongeometry_fraction": null,
|
15428
15619
|
"ssa_nongeometry_fraction": null,
|
15429
15620
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -15504,7 +15695,8 @@
|
|
15504
15695
|
"high_bay_lighting_schedule": null,
|
15505
15696
|
"specialty_lighting_schedule": null,
|
15506
15697
|
"exit_lighting_schedule": null,
|
15507
|
-
"target_illuminance_setpoint":
|
15698
|
+
"target_illuminance_setpoint": 150,
|
15699
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15508
15700
|
"psa_nongeometry_fraction": null,
|
15509
15701
|
"ssa_nongeometry_fraction": null,
|
15510
15702
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -15585,7 +15777,8 @@
|
|
15585
15777
|
"high_bay_lighting_schedule": null,
|
15586
15778
|
"specialty_lighting_schedule": null,
|
15587
15779
|
"exit_lighting_schedule": null,
|
15588
|
-
"target_illuminance_setpoint":
|
15780
|
+
"target_illuminance_setpoint": 400,
|
15781
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15589
15782
|
"psa_nongeometry_fraction": null,
|
15590
15783
|
"ssa_nongeometry_fraction": null,
|
15591
15784
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -15666,7 +15859,8 @@
|
|
15666
15859
|
"high_bay_lighting_schedule": null,
|
15667
15860
|
"specialty_lighting_schedule": null,
|
15668
15861
|
"exit_lighting_schedule": null,
|
15669
|
-
"target_illuminance_setpoint":
|
15862
|
+
"target_illuminance_setpoint": 400,
|
15863
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15670
15864
|
"psa_nongeometry_fraction": null,
|
15671
15865
|
"ssa_nongeometry_fraction": null,
|
15672
15866
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -15747,7 +15941,8 @@
|
|
15747
15941
|
"high_bay_lighting_schedule": null,
|
15748
15942
|
"specialty_lighting_schedule": null,
|
15749
15943
|
"exit_lighting_schedule": null,
|
15750
|
-
"target_illuminance_setpoint":
|
15944
|
+
"target_illuminance_setpoint": 400,
|
15945
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15751
15946
|
"psa_nongeometry_fraction": null,
|
15752
15947
|
"ssa_nongeometry_fraction": null,
|
15753
15948
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -15828,7 +16023,8 @@
|
|
15828
16023
|
"high_bay_lighting_schedule": null,
|
15829
16024
|
"specialty_lighting_schedule": null,
|
15830
16025
|
"exit_lighting_schedule": null,
|
15831
|
-
"target_illuminance_setpoint":
|
16026
|
+
"target_illuminance_setpoint": 400,
|
16027
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15832
16028
|
"psa_nongeometry_fraction": null,
|
15833
16029
|
"ssa_nongeometry_fraction": null,
|
15834
16030
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -15909,7 +16105,8 @@
|
|
15909
16105
|
"high_bay_lighting_schedule": null,
|
15910
16106
|
"specialty_lighting_schedule": null,
|
15911
16107
|
"exit_lighting_schedule": null,
|
15912
|
-
"target_illuminance_setpoint":
|
16108
|
+
"target_illuminance_setpoint": 500,
|
16109
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15913
16110
|
"psa_nongeometry_fraction": null,
|
15914
16111
|
"ssa_nongeometry_fraction": null,
|
15915
16112
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -15990,7 +16187,8 @@
|
|
15990
16187
|
"high_bay_lighting_schedule": null,
|
15991
16188
|
"specialty_lighting_schedule": null,
|
15992
16189
|
"exit_lighting_schedule": null,
|
15993
|
-
"target_illuminance_setpoint":
|
16190
|
+
"target_illuminance_setpoint": 150,
|
16191
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
15994
16192
|
"psa_nongeometry_fraction": null,
|
15995
16193
|
"ssa_nongeometry_fraction": null,
|
15996
16194
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16071,7 +16269,8 @@
|
|
16071
16269
|
"high_bay_lighting_schedule": null,
|
16072
16270
|
"specialty_lighting_schedule": null,
|
16073
16271
|
"exit_lighting_schedule": null,
|
16074
|
-
"target_illuminance_setpoint":
|
16272
|
+
"target_illuminance_setpoint": 150,
|
16273
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16075
16274
|
"psa_nongeometry_fraction": null,
|
16076
16275
|
"ssa_nongeometry_fraction": null,
|
16077
16276
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16152,7 +16351,8 @@
|
|
16152
16351
|
"high_bay_lighting_schedule": null,
|
16153
16352
|
"specialty_lighting_schedule": null,
|
16154
16353
|
"exit_lighting_schedule": null,
|
16155
|
-
"target_illuminance_setpoint":
|
16354
|
+
"target_illuminance_setpoint": 150,
|
16355
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16156
16356
|
"psa_nongeometry_fraction": null,
|
16157
16357
|
"ssa_nongeometry_fraction": null,
|
16158
16358
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16233,7 +16433,8 @@
|
|
16233
16433
|
"high_bay_lighting_schedule": null,
|
16234
16434
|
"specialty_lighting_schedule": null,
|
16235
16435
|
"exit_lighting_schedule": null,
|
16236
|
-
"target_illuminance_setpoint":
|
16436
|
+
"target_illuminance_setpoint": 150,
|
16437
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16237
16438
|
"psa_nongeometry_fraction": null,
|
16238
16439
|
"ssa_nongeometry_fraction": null,
|
16239
16440
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16314,7 +16515,8 @@
|
|
16314
16515
|
"high_bay_lighting_schedule": null,
|
16315
16516
|
"specialty_lighting_schedule": null,
|
16316
16517
|
"exit_lighting_schedule": null,
|
16317
|
-
"target_illuminance_setpoint":
|
16518
|
+
"target_illuminance_setpoint": 150,
|
16519
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16318
16520
|
"psa_nongeometry_fraction": null,
|
16319
16521
|
"ssa_nongeometry_fraction": null,
|
16320
16522
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16395,7 +16597,8 @@
|
|
16395
16597
|
"high_bay_lighting_schedule": null,
|
16396
16598
|
"specialty_lighting_schedule": null,
|
16397
16599
|
"exit_lighting_schedule": null,
|
16398
|
-
"target_illuminance_setpoint":
|
16600
|
+
"target_illuminance_setpoint": 150,
|
16601
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16399
16602
|
"psa_nongeometry_fraction": null,
|
16400
16603
|
"ssa_nongeometry_fraction": null,
|
16401
16604
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16476,7 +16679,8 @@
|
|
16476
16679
|
"high_bay_lighting_schedule": null,
|
16477
16680
|
"specialty_lighting_schedule": null,
|
16478
16681
|
"exit_lighting_schedule": null,
|
16479
|
-
"target_illuminance_setpoint":
|
16682
|
+
"target_illuminance_setpoint": 150,
|
16683
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16480
16684
|
"psa_nongeometry_fraction": null,
|
16481
16685
|
"ssa_nongeometry_fraction": null,
|
16482
16686
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16557,7 +16761,8 @@
|
|
16557
16761
|
"high_bay_lighting_schedule": null,
|
16558
16762
|
"specialty_lighting_schedule": null,
|
16559
16763
|
"exit_lighting_schedule": null,
|
16560
|
-
"target_illuminance_setpoint":
|
16764
|
+
"target_illuminance_setpoint": 150,
|
16765
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16561
16766
|
"psa_nongeometry_fraction": null,
|
16562
16767
|
"ssa_nongeometry_fraction": null,
|
16563
16768
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16638,7 +16843,8 @@
|
|
16638
16843
|
"high_bay_lighting_schedule": null,
|
16639
16844
|
"specialty_lighting_schedule": null,
|
16640
16845
|
"exit_lighting_schedule": null,
|
16641
|
-
"target_illuminance_setpoint":
|
16846
|
+
"target_illuminance_setpoint": 150,
|
16847
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16642
16848
|
"psa_nongeometry_fraction": null,
|
16643
16849
|
"ssa_nongeometry_fraction": null,
|
16644
16850
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16719,7 +16925,8 @@
|
|
16719
16925
|
"high_bay_lighting_schedule": null,
|
16720
16926
|
"specialty_lighting_schedule": null,
|
16721
16927
|
"exit_lighting_schedule": null,
|
16722
|
-
"target_illuminance_setpoint":
|
16928
|
+
"target_illuminance_setpoint": 150,
|
16929
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16723
16930
|
"psa_nongeometry_fraction": null,
|
16724
16931
|
"ssa_nongeometry_fraction": null,
|
16725
16932
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16800,7 +17007,8 @@
|
|
16800
17007
|
"high_bay_lighting_schedule": null,
|
16801
17008
|
"specialty_lighting_schedule": null,
|
16802
17009
|
"exit_lighting_schedule": null,
|
16803
|
-
"target_illuminance_setpoint":
|
17010
|
+
"target_illuminance_setpoint": 150,
|
17011
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16804
17012
|
"psa_nongeometry_fraction": null,
|
16805
17013
|
"ssa_nongeometry_fraction": null,
|
16806
17014
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16881,7 +17089,8 @@
|
|
16881
17089
|
"high_bay_lighting_schedule": null,
|
16882
17090
|
"specialty_lighting_schedule": null,
|
16883
17091
|
"exit_lighting_schedule": null,
|
16884
|
-
"target_illuminance_setpoint":
|
17092
|
+
"target_illuminance_setpoint": 150,
|
17093
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16885
17094
|
"psa_nongeometry_fraction": null,
|
16886
17095
|
"ssa_nongeometry_fraction": null,
|
16887
17096
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -16962,7 +17171,8 @@
|
|
16962
17171
|
"high_bay_lighting_schedule": null,
|
16963
17172
|
"specialty_lighting_schedule": null,
|
16964
17173
|
"exit_lighting_schedule": null,
|
16965
|
-
"target_illuminance_setpoint":
|
17174
|
+
"target_illuminance_setpoint": 150,
|
17175
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
16966
17176
|
"psa_nongeometry_fraction": null,
|
16967
17177
|
"ssa_nongeometry_fraction": null,
|
16968
17178
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -17043,7 +17253,8 @@
|
|
17043
17253
|
"high_bay_lighting_schedule": null,
|
17044
17254
|
"specialty_lighting_schedule": null,
|
17045
17255
|
"exit_lighting_schedule": null,
|
17046
|
-
"target_illuminance_setpoint":
|
17256
|
+
"target_illuminance_setpoint": 150,
|
17257
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17047
17258
|
"psa_nongeometry_fraction": null,
|
17048
17259
|
"ssa_nongeometry_fraction": null,
|
17049
17260
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -17124,7 +17335,8 @@
|
|
17124
17335
|
"high_bay_lighting_schedule": null,
|
17125
17336
|
"specialty_lighting_schedule": null,
|
17126
17337
|
"exit_lighting_schedule": null,
|
17127
|
-
"target_illuminance_setpoint":
|
17338
|
+
"target_illuminance_setpoint": 150,
|
17339
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17128
17340
|
"psa_nongeometry_fraction": null,
|
17129
17341
|
"ssa_nongeometry_fraction": null,
|
17130
17342
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -17205,7 +17417,8 @@
|
|
17205
17417
|
"high_bay_lighting_schedule": null,
|
17206
17418
|
"specialty_lighting_schedule": null,
|
17207
17419
|
"exit_lighting_schedule": null,
|
17208
|
-
"target_illuminance_setpoint":
|
17420
|
+
"target_illuminance_setpoint": 150,
|
17421
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17209
17422
|
"psa_nongeometry_fraction": null,
|
17210
17423
|
"ssa_nongeometry_fraction": null,
|
17211
17424
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -17286,7 +17499,8 @@
|
|
17286
17499
|
"high_bay_lighting_schedule": null,
|
17287
17500
|
"specialty_lighting_schedule": null,
|
17288
17501
|
"exit_lighting_schedule": null,
|
17289
|
-
"target_illuminance_setpoint":
|
17502
|
+
"target_illuminance_setpoint": 150,
|
17503
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17290
17504
|
"psa_nongeometry_fraction": null,
|
17291
17505
|
"ssa_nongeometry_fraction": null,
|
17292
17506
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -17367,7 +17581,8 @@
|
|
17367
17581
|
"high_bay_lighting_schedule": null,
|
17368
17582
|
"specialty_lighting_schedule": null,
|
17369
17583
|
"exit_lighting_schedule": null,
|
17370
|
-
"target_illuminance_setpoint":
|
17584
|
+
"target_illuminance_setpoint": 150,
|
17585
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17371
17586
|
"psa_nongeometry_fraction": null,
|
17372
17587
|
"ssa_nongeometry_fraction": null,
|
17373
17588
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -17448,7 +17663,8 @@
|
|
17448
17663
|
"high_bay_lighting_schedule": null,
|
17449
17664
|
"specialty_lighting_schedule": null,
|
17450
17665
|
"exit_lighting_schedule": null,
|
17451
|
-
"target_illuminance_setpoint":
|
17666
|
+
"target_illuminance_setpoint": 150,
|
17667
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17452
17668
|
"psa_nongeometry_fraction": null,
|
17453
17669
|
"ssa_nongeometry_fraction": null,
|
17454
17670
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -17529,7 +17745,8 @@
|
|
17529
17745
|
"high_bay_lighting_schedule": null,
|
17530
17746
|
"specialty_lighting_schedule": null,
|
17531
17747
|
"exit_lighting_schedule": null,
|
17532
|
-
"target_illuminance_setpoint":
|
17748
|
+
"target_illuminance_setpoint": 150,
|
17749
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17533
17750
|
"psa_nongeometry_fraction": null,
|
17534
17751
|
"ssa_nongeometry_fraction": null,
|
17535
17752
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -17610,7 +17827,8 @@
|
|
17610
17827
|
"high_bay_lighting_schedule": null,
|
17611
17828
|
"specialty_lighting_schedule": null,
|
17612
17829
|
"exit_lighting_schedule": null,
|
17613
|
-
"target_illuminance_setpoint":
|
17830
|
+
"target_illuminance_setpoint": 150,
|
17831
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17614
17832
|
"psa_nongeometry_fraction": null,
|
17615
17833
|
"ssa_nongeometry_fraction": null,
|
17616
17834
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -17691,7 +17909,8 @@
|
|
17691
17909
|
"high_bay_lighting_schedule": null,
|
17692
17910
|
"specialty_lighting_schedule": null,
|
17693
17911
|
"exit_lighting_schedule": null,
|
17694
|
-
"target_illuminance_setpoint":
|
17912
|
+
"target_illuminance_setpoint": 150,
|
17913
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17695
17914
|
"psa_nongeometry_fraction": null,
|
17696
17915
|
"ssa_nongeometry_fraction": null,
|
17697
17916
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -17772,7 +17991,8 @@
|
|
17772
17991
|
"high_bay_lighting_schedule": null,
|
17773
17992
|
"specialty_lighting_schedule": null,
|
17774
17993
|
"exit_lighting_schedule": null,
|
17775
|
-
"target_illuminance_setpoint":
|
17994
|
+
"target_illuminance_setpoint": 75,
|
17995
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17776
17996
|
"psa_nongeometry_fraction": null,
|
17777
17997
|
"ssa_nongeometry_fraction": null,
|
17778
17998
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -17853,7 +18073,8 @@
|
|
17853
18073
|
"high_bay_lighting_schedule": null,
|
17854
18074
|
"specialty_lighting_schedule": null,
|
17855
18075
|
"exit_lighting_schedule": null,
|
17856
|
-
"target_illuminance_setpoint":
|
18076
|
+
"target_illuminance_setpoint": 100,
|
18077
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17857
18078
|
"psa_nongeometry_fraction": null,
|
17858
18079
|
"ssa_nongeometry_fraction": null,
|
17859
18080
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -17934,7 +18155,8 @@
|
|
17934
18155
|
"high_bay_lighting_schedule": null,
|
17935
18156
|
"specialty_lighting_schedule": null,
|
17936
18157
|
"exit_lighting_schedule": null,
|
17937
|
-
"target_illuminance_setpoint":
|
18158
|
+
"target_illuminance_setpoint": 100,
|
18159
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
17938
18160
|
"psa_nongeometry_fraction": null,
|
17939
18161
|
"ssa_nongeometry_fraction": null,
|
17940
18162
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18015,7 +18237,8 @@
|
|
18015
18237
|
"high_bay_lighting_schedule": null,
|
18016
18238
|
"specialty_lighting_schedule": null,
|
18017
18239
|
"exit_lighting_schedule": null,
|
18018
|
-
"target_illuminance_setpoint":
|
18240
|
+
"target_illuminance_setpoint": 100,
|
18241
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18019
18242
|
"psa_nongeometry_fraction": null,
|
18020
18243
|
"ssa_nongeometry_fraction": null,
|
18021
18244
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18096,7 +18319,8 @@
|
|
18096
18319
|
"high_bay_lighting_schedule": null,
|
18097
18320
|
"specialty_lighting_schedule": null,
|
18098
18321
|
"exit_lighting_schedule": null,
|
18099
|
-
"target_illuminance_setpoint":
|
18322
|
+
"target_illuminance_setpoint": 100,
|
18323
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18100
18324
|
"psa_nongeometry_fraction": null,
|
18101
18325
|
"ssa_nongeometry_fraction": null,
|
18102
18326
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18177,7 +18401,8 @@
|
|
18177
18401
|
"high_bay_lighting_schedule": null,
|
18178
18402
|
"specialty_lighting_schedule": null,
|
18179
18403
|
"exit_lighting_schedule": null,
|
18180
|
-
"target_illuminance_setpoint":
|
18404
|
+
"target_illuminance_setpoint": 100,
|
18405
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18181
18406
|
"psa_nongeometry_fraction": null,
|
18182
18407
|
"ssa_nongeometry_fraction": null,
|
18183
18408
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18258,7 +18483,8 @@
|
|
18258
18483
|
"high_bay_lighting_schedule": null,
|
18259
18484
|
"specialty_lighting_schedule": null,
|
18260
18485
|
"exit_lighting_schedule": null,
|
18261
|
-
"target_illuminance_setpoint":
|
18486
|
+
"target_illuminance_setpoint": 100,
|
18487
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18262
18488
|
"psa_nongeometry_fraction": null,
|
18263
18489
|
"ssa_nongeometry_fraction": null,
|
18264
18490
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18339,7 +18565,8 @@
|
|
18339
18565
|
"high_bay_lighting_schedule": null,
|
18340
18566
|
"specialty_lighting_schedule": null,
|
18341
18567
|
"exit_lighting_schedule": null,
|
18342
|
-
"target_illuminance_setpoint":
|
18568
|
+
"target_illuminance_setpoint": 100,
|
18569
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18343
18570
|
"psa_nongeometry_fraction": null,
|
18344
18571
|
"ssa_nongeometry_fraction": null,
|
18345
18572
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18420,7 +18647,8 @@
|
|
18420
18647
|
"high_bay_lighting_schedule": null,
|
18421
18648
|
"specialty_lighting_schedule": null,
|
18422
18649
|
"exit_lighting_schedule": null,
|
18423
|
-
"target_illuminance_setpoint":
|
18650
|
+
"target_illuminance_setpoint": 100,
|
18651
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18424
18652
|
"psa_nongeometry_fraction": null,
|
18425
18653
|
"ssa_nongeometry_fraction": null,
|
18426
18654
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18501,7 +18729,8 @@
|
|
18501
18729
|
"high_bay_lighting_schedule": null,
|
18502
18730
|
"specialty_lighting_schedule": null,
|
18503
18731
|
"exit_lighting_schedule": null,
|
18504
|
-
"target_illuminance_setpoint":
|
18732
|
+
"target_illuminance_setpoint": 100,
|
18733
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18505
18734
|
"psa_nongeometry_fraction": null,
|
18506
18735
|
"ssa_nongeometry_fraction": null,
|
18507
18736
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18582,7 +18811,8 @@
|
|
18582
18811
|
"high_bay_lighting_schedule": null,
|
18583
18812
|
"specialty_lighting_schedule": null,
|
18584
18813
|
"exit_lighting_schedule": null,
|
18585
|
-
"target_illuminance_setpoint":
|
18814
|
+
"target_illuminance_setpoint": 100,
|
18815
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18586
18816
|
"psa_nongeometry_fraction": null,
|
18587
18817
|
"ssa_nongeometry_fraction": null,
|
18588
18818
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18663,7 +18893,8 @@
|
|
18663
18893
|
"high_bay_lighting_schedule": null,
|
18664
18894
|
"specialty_lighting_schedule": null,
|
18665
18895
|
"exit_lighting_schedule": null,
|
18666
|
-
"target_illuminance_setpoint":
|
18896
|
+
"target_illuminance_setpoint": 100,
|
18897
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18667
18898
|
"psa_nongeometry_fraction": null,
|
18668
18899
|
"ssa_nongeometry_fraction": null,
|
18669
18900
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18744,7 +18975,8 @@
|
|
18744
18975
|
"high_bay_lighting_schedule": null,
|
18745
18976
|
"specialty_lighting_schedule": null,
|
18746
18977
|
"exit_lighting_schedule": null,
|
18747
|
-
"target_illuminance_setpoint":
|
18978
|
+
"target_illuminance_setpoint": 100,
|
18979
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18748
18980
|
"psa_nongeometry_fraction": null,
|
18749
18981
|
"ssa_nongeometry_fraction": null,
|
18750
18982
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18825,7 +19057,8 @@
|
|
18825
19057
|
"high_bay_lighting_schedule": null,
|
18826
19058
|
"specialty_lighting_schedule": null,
|
18827
19059
|
"exit_lighting_schedule": null,
|
18828
|
-
"target_illuminance_setpoint":
|
19060
|
+
"target_illuminance_setpoint": 100,
|
19061
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18829
19062
|
"psa_nongeometry_fraction": null,
|
18830
19063
|
"ssa_nongeometry_fraction": null,
|
18831
19064
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18906,7 +19139,8 @@
|
|
18906
19139
|
"high_bay_lighting_schedule": null,
|
18907
19140
|
"specialty_lighting_schedule": null,
|
18908
19141
|
"exit_lighting_schedule": null,
|
18909
|
-
"target_illuminance_setpoint":
|
19142
|
+
"target_illuminance_setpoint": 100,
|
19143
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18910
19144
|
"psa_nongeometry_fraction": null,
|
18911
19145
|
"ssa_nongeometry_fraction": null,
|
18912
19146
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -18987,7 +19221,8 @@
|
|
18987
19221
|
"high_bay_lighting_schedule": null,
|
18988
19222
|
"specialty_lighting_schedule": null,
|
18989
19223
|
"exit_lighting_schedule": null,
|
18990
|
-
"target_illuminance_setpoint":
|
19224
|
+
"target_illuminance_setpoint": 100,
|
19225
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
18991
19226
|
"psa_nongeometry_fraction": null,
|
18992
19227
|
"ssa_nongeometry_fraction": null,
|
18993
19228
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -19068,7 +19303,8 @@
|
|
19068
19303
|
"high_bay_lighting_schedule": null,
|
19069
19304
|
"specialty_lighting_schedule": null,
|
19070
19305
|
"exit_lighting_schedule": null,
|
19071
|
-
"target_illuminance_setpoint":
|
19306
|
+
"target_illuminance_setpoint": 100,
|
19307
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19072
19308
|
"psa_nongeometry_fraction": null,
|
19073
19309
|
"ssa_nongeometry_fraction": null,
|
19074
19310
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -19149,7 +19385,8 @@
|
|
19149
19385
|
"high_bay_lighting_schedule": null,
|
19150
19386
|
"specialty_lighting_schedule": null,
|
19151
19387
|
"exit_lighting_schedule": null,
|
19152
|
-
"target_illuminance_setpoint":
|
19388
|
+
"target_illuminance_setpoint": 100,
|
19389
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19153
19390
|
"psa_nongeometry_fraction": null,
|
19154
19391
|
"ssa_nongeometry_fraction": null,
|
19155
19392
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -19230,7 +19467,8 @@
|
|
19230
19467
|
"high_bay_lighting_schedule": null,
|
19231
19468
|
"specialty_lighting_schedule": null,
|
19232
19469
|
"exit_lighting_schedule": null,
|
19233
|
-
"target_illuminance_setpoint":
|
19470
|
+
"target_illuminance_setpoint": 100,
|
19471
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19234
19472
|
"psa_nongeometry_fraction": null,
|
19235
19473
|
"ssa_nongeometry_fraction": null,
|
19236
19474
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -19311,7 +19549,8 @@
|
|
19311
19549
|
"high_bay_lighting_schedule": null,
|
19312
19550
|
"specialty_lighting_schedule": null,
|
19313
19551
|
"exit_lighting_schedule": null,
|
19314
|
-
"target_illuminance_setpoint":
|
19552
|
+
"target_illuminance_setpoint": 100,
|
19553
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19315
19554
|
"psa_nongeometry_fraction": null,
|
19316
19555
|
"ssa_nongeometry_fraction": null,
|
19317
19556
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -19392,7 +19631,8 @@
|
|
19392
19631
|
"high_bay_lighting_schedule": null,
|
19393
19632
|
"specialty_lighting_schedule": null,
|
19394
19633
|
"exit_lighting_schedule": null,
|
19395
|
-
"target_illuminance_setpoint":
|
19634
|
+
"target_illuminance_setpoint": 100,
|
19635
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19396
19636
|
"psa_nongeometry_fraction": null,
|
19397
19637
|
"ssa_nongeometry_fraction": null,
|
19398
19638
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -19473,7 +19713,8 @@
|
|
19473
19713
|
"high_bay_lighting_schedule": null,
|
19474
19714
|
"specialty_lighting_schedule": null,
|
19475
19715
|
"exit_lighting_schedule": null,
|
19476
|
-
"target_illuminance_setpoint":
|
19716
|
+
"target_illuminance_setpoint": 100,
|
19717
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19477
19718
|
"psa_nongeometry_fraction": null,
|
19478
19719
|
"ssa_nongeometry_fraction": null,
|
19479
19720
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -19554,7 +19795,8 @@
|
|
19554
19795
|
"high_bay_lighting_schedule": null,
|
19555
19796
|
"specialty_lighting_schedule": null,
|
19556
19797
|
"exit_lighting_schedule": null,
|
19557
|
-
"target_illuminance_setpoint":
|
19798
|
+
"target_illuminance_setpoint": 100,
|
19799
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19558
19800
|
"psa_nongeometry_fraction": null,
|
19559
19801
|
"ssa_nongeometry_fraction": null,
|
19560
19802
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -19635,7 +19877,8 @@
|
|
19635
19877
|
"high_bay_lighting_schedule": null,
|
19636
19878
|
"specialty_lighting_schedule": null,
|
19637
19879
|
"exit_lighting_schedule": null,
|
19638
|
-
"target_illuminance_setpoint":
|
19880
|
+
"target_illuminance_setpoint": 500,
|
19881
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19639
19882
|
"psa_nongeometry_fraction": null,
|
19640
19883
|
"ssa_nongeometry_fraction": null,
|
19641
19884
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -19716,7 +19959,8 @@
|
|
19716
19959
|
"high_bay_lighting_schedule": null,
|
19717
19960
|
"specialty_lighting_schedule": null,
|
19718
19961
|
"exit_lighting_schedule": null,
|
19719
|
-
"target_illuminance_setpoint":
|
19962
|
+
"target_illuminance_setpoint": 150,
|
19963
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19720
19964
|
"psa_nongeometry_fraction": null,
|
19721
19965
|
"ssa_nongeometry_fraction": null,
|
19722
19966
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -19797,7 +20041,8 @@
|
|
19797
20041
|
"high_bay_lighting_schedule": null,
|
19798
20042
|
"specialty_lighting_schedule": null,
|
19799
20043
|
"exit_lighting_schedule": null,
|
19800
|
-
"target_illuminance_setpoint":
|
20044
|
+
"target_illuminance_setpoint": 150,
|
20045
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19801
20046
|
"psa_nongeometry_fraction": null,
|
19802
20047
|
"ssa_nongeometry_fraction": null,
|
19803
20048
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -19878,7 +20123,8 @@
|
|
19878
20123
|
"high_bay_lighting_schedule": null,
|
19879
20124
|
"specialty_lighting_schedule": null,
|
19880
20125
|
"exit_lighting_schedule": null,
|
19881
|
-
"target_illuminance_setpoint":
|
20126
|
+
"target_illuminance_setpoint": 150,
|
20127
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19882
20128
|
"psa_nongeometry_fraction": null,
|
19883
20129
|
"ssa_nongeometry_fraction": null,
|
19884
20130
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -19959,7 +20205,8 @@
|
|
19959
20205
|
"high_bay_lighting_schedule": null,
|
19960
20206
|
"specialty_lighting_schedule": null,
|
19961
20207
|
"exit_lighting_schedule": null,
|
19962
|
-
"target_illuminance_setpoint":
|
20208
|
+
"target_illuminance_setpoint": 150,
|
20209
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
19963
20210
|
"psa_nongeometry_fraction": null,
|
19964
20211
|
"ssa_nongeometry_fraction": null,
|
19965
20212
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20040,7 +20287,8 @@
|
|
20040
20287
|
"high_bay_lighting_schedule": null,
|
20041
20288
|
"specialty_lighting_schedule": null,
|
20042
20289
|
"exit_lighting_schedule": null,
|
20043
|
-
"target_illuminance_setpoint":
|
20290
|
+
"target_illuminance_setpoint": 150,
|
20291
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20044
20292
|
"psa_nongeometry_fraction": null,
|
20045
20293
|
"ssa_nongeometry_fraction": null,
|
20046
20294
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20121,7 +20369,8 @@
|
|
20121
20369
|
"high_bay_lighting_schedule": null,
|
20122
20370
|
"specialty_lighting_schedule": null,
|
20123
20371
|
"exit_lighting_schedule": null,
|
20124
|
-
"target_illuminance_setpoint":
|
20372
|
+
"target_illuminance_setpoint": 150,
|
20373
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20125
20374
|
"psa_nongeometry_fraction": null,
|
20126
20375
|
"ssa_nongeometry_fraction": null,
|
20127
20376
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20202,7 +20451,8 @@
|
|
20202
20451
|
"high_bay_lighting_schedule": null,
|
20203
20452
|
"specialty_lighting_schedule": null,
|
20204
20453
|
"exit_lighting_schedule": null,
|
20205
|
-
"target_illuminance_setpoint":
|
20454
|
+
"target_illuminance_setpoint": 150,
|
20455
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20206
20456
|
"psa_nongeometry_fraction": null,
|
20207
20457
|
"ssa_nongeometry_fraction": null,
|
20208
20458
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20283,7 +20533,8 @@
|
|
20283
20533
|
"high_bay_lighting_schedule": null,
|
20284
20534
|
"specialty_lighting_schedule": null,
|
20285
20535
|
"exit_lighting_schedule": null,
|
20286
|
-
"target_illuminance_setpoint":
|
20536
|
+
"target_illuminance_setpoint": 150,
|
20537
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20287
20538
|
"psa_nongeometry_fraction": null,
|
20288
20539
|
"ssa_nongeometry_fraction": null,
|
20289
20540
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20364,7 +20615,8 @@
|
|
20364
20615
|
"high_bay_lighting_schedule": null,
|
20365
20616
|
"specialty_lighting_schedule": null,
|
20366
20617
|
"exit_lighting_schedule": null,
|
20367
|
-
"target_illuminance_setpoint":
|
20618
|
+
"target_illuminance_setpoint": 150,
|
20619
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20368
20620
|
"psa_nongeometry_fraction": null,
|
20369
20621
|
"ssa_nongeometry_fraction": null,
|
20370
20622
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20445,7 +20697,8 @@
|
|
20445
20697
|
"high_bay_lighting_schedule": null,
|
20446
20698
|
"specialty_lighting_schedule": null,
|
20447
20699
|
"exit_lighting_schedule": null,
|
20448
|
-
"target_illuminance_setpoint":
|
20700
|
+
"target_illuminance_setpoint": 150,
|
20701
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20449
20702
|
"psa_nongeometry_fraction": null,
|
20450
20703
|
"ssa_nongeometry_fraction": null,
|
20451
20704
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20526,7 +20779,8 @@
|
|
20526
20779
|
"high_bay_lighting_schedule": null,
|
20527
20780
|
"specialty_lighting_schedule": null,
|
20528
20781
|
"exit_lighting_schedule": null,
|
20529
|
-
"target_illuminance_setpoint":
|
20782
|
+
"target_illuminance_setpoint": 150,
|
20783
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20530
20784
|
"psa_nongeometry_fraction": null,
|
20531
20785
|
"ssa_nongeometry_fraction": null,
|
20532
20786
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20607,7 +20861,8 @@
|
|
20607
20861
|
"high_bay_lighting_schedule": null,
|
20608
20862
|
"specialty_lighting_schedule": null,
|
20609
20863
|
"exit_lighting_schedule": null,
|
20610
|
-
"target_illuminance_setpoint":
|
20864
|
+
"target_illuminance_setpoint": 150,
|
20865
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20611
20866
|
"psa_nongeometry_fraction": null,
|
20612
20867
|
"ssa_nongeometry_fraction": null,
|
20613
20868
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20688,7 +20943,8 @@
|
|
20688
20943
|
"high_bay_lighting_schedule": null,
|
20689
20944
|
"specialty_lighting_schedule": null,
|
20690
20945
|
"exit_lighting_schedule": null,
|
20691
|
-
"target_illuminance_setpoint":
|
20946
|
+
"target_illuminance_setpoint": 150,
|
20947
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20692
20948
|
"psa_nongeometry_fraction": null,
|
20693
20949
|
"ssa_nongeometry_fraction": null,
|
20694
20950
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20769,7 +21025,8 @@
|
|
20769
21025
|
"high_bay_lighting_schedule": null,
|
20770
21026
|
"specialty_lighting_schedule": null,
|
20771
21027
|
"exit_lighting_schedule": null,
|
20772
|
-
"target_illuminance_setpoint":
|
21028
|
+
"target_illuminance_setpoint": 150,
|
21029
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20773
21030
|
"psa_nongeometry_fraction": null,
|
20774
21031
|
"ssa_nongeometry_fraction": null,
|
20775
21032
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20850,7 +21107,8 @@
|
|
20850
21107
|
"high_bay_lighting_schedule": null,
|
20851
21108
|
"specialty_lighting_schedule": null,
|
20852
21109
|
"exit_lighting_schedule": null,
|
20853
|
-
"target_illuminance_setpoint":
|
21110
|
+
"target_illuminance_setpoint": 150,
|
21111
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20854
21112
|
"psa_nongeometry_fraction": null,
|
20855
21113
|
"ssa_nongeometry_fraction": null,
|
20856
21114
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -20931,7 +21189,8 @@
|
|
20931
21189
|
"high_bay_lighting_schedule": null,
|
20932
21190
|
"specialty_lighting_schedule": null,
|
20933
21191
|
"exit_lighting_schedule": null,
|
20934
|
-
"target_illuminance_setpoint":
|
21192
|
+
"target_illuminance_setpoint": 150,
|
21193
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
20935
21194
|
"psa_nongeometry_fraction": null,
|
20936
21195
|
"ssa_nongeometry_fraction": null,
|
20937
21196
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -21012,7 +21271,8 @@
|
|
21012
21271
|
"high_bay_lighting_schedule": null,
|
21013
21272
|
"specialty_lighting_schedule": null,
|
21014
21273
|
"exit_lighting_schedule": null,
|
21015
|
-
"target_illuminance_setpoint":
|
21274
|
+
"target_illuminance_setpoint": 150,
|
21275
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21016
21276
|
"psa_nongeometry_fraction": null,
|
21017
21277
|
"ssa_nongeometry_fraction": null,
|
21018
21278
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -21093,7 +21353,8 @@
|
|
21093
21353
|
"high_bay_lighting_schedule": null,
|
21094
21354
|
"specialty_lighting_schedule": null,
|
21095
21355
|
"exit_lighting_schedule": null,
|
21096
|
-
"target_illuminance_setpoint":
|
21356
|
+
"target_illuminance_setpoint": 150,
|
21357
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21097
21358
|
"psa_nongeometry_fraction": null,
|
21098
21359
|
"ssa_nongeometry_fraction": null,
|
21099
21360
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -21174,7 +21435,8 @@
|
|
21174
21435
|
"high_bay_lighting_schedule": null,
|
21175
21436
|
"specialty_lighting_schedule": null,
|
21176
21437
|
"exit_lighting_schedule": null,
|
21177
|
-
"target_illuminance_setpoint":
|
21438
|
+
"target_illuminance_setpoint": 150,
|
21439
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21178
21440
|
"psa_nongeometry_fraction": null,
|
21179
21441
|
"ssa_nongeometry_fraction": null,
|
21180
21442
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -21255,7 +21517,8 @@
|
|
21255
21517
|
"high_bay_lighting_schedule": null,
|
21256
21518
|
"specialty_lighting_schedule": null,
|
21257
21519
|
"exit_lighting_schedule": null,
|
21258
|
-
"target_illuminance_setpoint":
|
21520
|
+
"target_illuminance_setpoint": 150,
|
21521
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21259
21522
|
"psa_nongeometry_fraction": null,
|
21260
21523
|
"ssa_nongeometry_fraction": null,
|
21261
21524
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -21336,7 +21599,8 @@
|
|
21336
21599
|
"high_bay_lighting_schedule": null,
|
21337
21600
|
"specialty_lighting_schedule": null,
|
21338
21601
|
"exit_lighting_schedule": null,
|
21339
|
-
"target_illuminance_setpoint":
|
21602
|
+
"target_illuminance_setpoint": 150,
|
21603
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21340
21604
|
"psa_nongeometry_fraction": null,
|
21341
21605
|
"ssa_nongeometry_fraction": null,
|
21342
21606
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -21417,7 +21681,8 @@
|
|
21417
21681
|
"high_bay_lighting_schedule": null,
|
21418
21682
|
"specialty_lighting_schedule": null,
|
21419
21683
|
"exit_lighting_schedule": null,
|
21420
|
-
"target_illuminance_setpoint":
|
21684
|
+
"target_illuminance_setpoint": 150,
|
21685
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21421
21686
|
"psa_nongeometry_fraction": null,
|
21422
21687
|
"ssa_nongeometry_fraction": null,
|
21423
21688
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -21498,7 +21763,8 @@
|
|
21498
21763
|
"high_bay_lighting_schedule": null,
|
21499
21764
|
"specialty_lighting_schedule": null,
|
21500
21765
|
"exit_lighting_schedule": null,
|
21501
|
-
"target_illuminance_setpoint":
|
21766
|
+
"target_illuminance_setpoint": 500,
|
21767
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21502
21768
|
"psa_nongeometry_fraction": null,
|
21503
21769
|
"ssa_nongeometry_fraction": null,
|
21504
21770
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -21579,7 +21845,8 @@
|
|
21579
21845
|
"high_bay_lighting_schedule": null,
|
21580
21846
|
"specialty_lighting_schedule": null,
|
21581
21847
|
"exit_lighting_schedule": null,
|
21582
|
-
"target_illuminance_setpoint":
|
21848
|
+
"target_illuminance_setpoint": 500,
|
21849
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21583
21850
|
"psa_nongeometry_fraction": null,
|
21584
21851
|
"ssa_nongeometry_fraction": null,
|
21585
21852
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -21660,7 +21927,8 @@
|
|
21660
21927
|
"high_bay_lighting_schedule": null,
|
21661
21928
|
"specialty_lighting_schedule": null,
|
21662
21929
|
"exit_lighting_schedule": null,
|
21663
|
-
"target_illuminance_setpoint":
|
21930
|
+
"target_illuminance_setpoint": 125,
|
21931
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21664
21932
|
"psa_nongeometry_fraction": null,
|
21665
21933
|
"ssa_nongeometry_fraction": null,
|
21666
21934
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -21741,7 +22009,8 @@
|
|
21741
22009
|
"high_bay_lighting_schedule": null,
|
21742
22010
|
"specialty_lighting_schedule": null,
|
21743
22011
|
"exit_lighting_schedule": null,
|
21744
|
-
"target_illuminance_setpoint":
|
22012
|
+
"target_illuminance_setpoint": 125,
|
22013
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21745
22014
|
"psa_nongeometry_fraction": null,
|
21746
22015
|
"ssa_nongeometry_fraction": null,
|
21747
22016
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -21822,7 +22091,8 @@
|
|
21822
22091
|
"high_bay_lighting_schedule": null,
|
21823
22092
|
"specialty_lighting_schedule": null,
|
21824
22093
|
"exit_lighting_schedule": null,
|
21825
|
-
"target_illuminance_setpoint":
|
22094
|
+
"target_illuminance_setpoint": 300,
|
22095
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21826
22096
|
"psa_nongeometry_fraction": null,
|
21827
22097
|
"ssa_nongeometry_fraction": null,
|
21828
22098
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -21903,7 +22173,8 @@
|
|
21903
22173
|
"high_bay_lighting_schedule": null,
|
21904
22174
|
"specialty_lighting_schedule": null,
|
21905
22175
|
"exit_lighting_schedule": null,
|
21906
|
-
"target_illuminance_setpoint":
|
22176
|
+
"target_illuminance_setpoint": 150,
|
22177
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21907
22178
|
"psa_nongeometry_fraction": null,
|
21908
22179
|
"ssa_nongeometry_fraction": null,
|
21909
22180
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -21984,7 +22255,8 @@
|
|
21984
22255
|
"high_bay_lighting_schedule": null,
|
21985
22256
|
"specialty_lighting_schedule": null,
|
21986
22257
|
"exit_lighting_schedule": null,
|
21987
|
-
"target_illuminance_setpoint":
|
22258
|
+
"target_illuminance_setpoint": 350,
|
22259
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
21988
22260
|
"psa_nongeometry_fraction": null,
|
21989
22261
|
"ssa_nongeometry_fraction": null,
|
21990
22262
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -22065,7 +22337,8 @@
|
|
22065
22337
|
"high_bay_lighting_schedule": null,
|
22066
22338
|
"specialty_lighting_schedule": null,
|
22067
22339
|
"exit_lighting_schedule": null,
|
22068
|
-
"target_illuminance_setpoint":
|
22340
|
+
"target_illuminance_setpoint": 350,
|
22341
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22069
22342
|
"psa_nongeometry_fraction": null,
|
22070
22343
|
"ssa_nongeometry_fraction": null,
|
22071
22344
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -22146,7 +22419,8 @@
|
|
22146
22419
|
"high_bay_lighting_schedule": null,
|
22147
22420
|
"specialty_lighting_schedule": null,
|
22148
22421
|
"exit_lighting_schedule": null,
|
22149
|
-
"target_illuminance_setpoint":
|
22422
|
+
"target_illuminance_setpoint": 600,
|
22423
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22150
22424
|
"psa_nongeometry_fraction": null,
|
22151
22425
|
"ssa_nongeometry_fraction": null,
|
22152
22426
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -22227,7 +22501,8 @@
|
|
22227
22501
|
"high_bay_lighting_schedule": null,
|
22228
22502
|
"specialty_lighting_schedule": null,
|
22229
22503
|
"exit_lighting_schedule": null,
|
22230
|
-
"target_illuminance_setpoint":
|
22504
|
+
"target_illuminance_setpoint": 225,
|
22505
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22231
22506
|
"psa_nongeometry_fraction": null,
|
22232
22507
|
"ssa_nongeometry_fraction": null,
|
22233
22508
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -22308,7 +22583,8 @@
|
|
22308
22583
|
"high_bay_lighting_schedule": null,
|
22309
22584
|
"specialty_lighting_schedule": null,
|
22310
22585
|
"exit_lighting_schedule": null,
|
22311
|
-
"target_illuminance_setpoint":
|
22586
|
+
"target_illuminance_setpoint": 400,
|
22587
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22312
22588
|
"psa_nongeometry_fraction": null,
|
22313
22589
|
"ssa_nongeometry_fraction": null,
|
22314
22590
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -22389,7 +22665,8 @@
|
|
22389
22665
|
"high_bay_lighting_schedule": null,
|
22390
22666
|
"specialty_lighting_schedule": null,
|
22391
22667
|
"exit_lighting_schedule": null,
|
22392
|
-
"target_illuminance_setpoint":
|
22668
|
+
"target_illuminance_setpoint": 400,
|
22669
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22393
22670
|
"psa_nongeometry_fraction": null,
|
22394
22671
|
"ssa_nongeometry_fraction": null,
|
22395
22672
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -22470,7 +22747,8 @@
|
|
22470
22747
|
"high_bay_lighting_schedule": null,
|
22471
22748
|
"specialty_lighting_schedule": null,
|
22472
22749
|
"exit_lighting_schedule": null,
|
22473
|
-
"target_illuminance_setpoint":
|
22750
|
+
"target_illuminance_setpoint": 400,
|
22751
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22474
22752
|
"psa_nongeometry_fraction": null,
|
22475
22753
|
"ssa_nongeometry_fraction": null,
|
22476
22754
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -22551,7 +22829,8 @@
|
|
22551
22829
|
"high_bay_lighting_schedule": null,
|
22552
22830
|
"specialty_lighting_schedule": null,
|
22553
22831
|
"exit_lighting_schedule": null,
|
22554
|
-
"target_illuminance_setpoint":
|
22832
|
+
"target_illuminance_setpoint": 1000,
|
22833
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22555
22834
|
"psa_nongeometry_fraction": null,
|
22556
22835
|
"ssa_nongeometry_fraction": null,
|
22557
22836
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -22632,7 +22911,8 @@
|
|
22632
22911
|
"high_bay_lighting_schedule": null,
|
22633
22912
|
"specialty_lighting_schedule": null,
|
22634
22913
|
"exit_lighting_schedule": null,
|
22635
|
-
"target_illuminance_setpoint":
|
22914
|
+
"target_illuminance_setpoint": 400,
|
22915
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22636
22916
|
"psa_nongeometry_fraction": null,
|
22637
22917
|
"ssa_nongeometry_fraction": null,
|
22638
22918
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -22713,7 +22993,8 @@
|
|
22713
22993
|
"high_bay_lighting_schedule": null,
|
22714
22994
|
"specialty_lighting_schedule": null,
|
22715
22995
|
"exit_lighting_schedule": null,
|
22716
|
-
"target_illuminance_setpoint":
|
22996
|
+
"target_illuminance_setpoint": 350,
|
22997
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22717
22998
|
"psa_nongeometry_fraction": null,
|
22718
22999
|
"ssa_nongeometry_fraction": null,
|
22719
23000
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -22794,7 +23075,8 @@
|
|
22794
23075
|
"high_bay_lighting_schedule": null,
|
22795
23076
|
"specialty_lighting_schedule": null,
|
22796
23077
|
"exit_lighting_schedule": null,
|
22797
|
-
"target_illuminance_setpoint":
|
23078
|
+
"target_illuminance_setpoint": 250,
|
23079
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22798
23080
|
"psa_nongeometry_fraction": null,
|
22799
23081
|
"ssa_nongeometry_fraction": null,
|
22800
23082
|
"ventilation_standard": "ASHRAE 170-2008 Table 7-1",
|
@@ -22875,7 +23157,8 @@
|
|
22875
23157
|
"high_bay_lighting_schedule": null,
|
22876
23158
|
"specialty_lighting_schedule": null,
|
22877
23159
|
"exit_lighting_schedule": null,
|
22878
|
-
"target_illuminance_setpoint":
|
23160
|
+
"target_illuminance_setpoint": 500,
|
23161
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22879
23162
|
"psa_nongeometry_fraction": null,
|
22880
23163
|
"ssa_nongeometry_fraction": null,
|
22881
23164
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -22956,7 +23239,8 @@
|
|
22956
23239
|
"high_bay_lighting_schedule": null,
|
22957
23240
|
"specialty_lighting_schedule": null,
|
22958
23241
|
"exit_lighting_schedule": null,
|
22959
|
-
"target_illuminance_setpoint":
|
23242
|
+
"target_illuminance_setpoint": 500,
|
23243
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
22960
23244
|
"psa_nongeometry_fraction": null,
|
22961
23245
|
"ssa_nongeometry_fraction": null,
|
22962
23246
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -23037,7 +23321,8 @@
|
|
23037
23321
|
"high_bay_lighting_schedule": null,
|
23038
23322
|
"specialty_lighting_schedule": null,
|
23039
23323
|
"exit_lighting_schedule": null,
|
23040
|
-
"target_illuminance_setpoint":
|
23324
|
+
"target_illuminance_setpoint": 600,
|
23325
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23041
23326
|
"psa_nongeometry_fraction": null,
|
23042
23327
|
"ssa_nongeometry_fraction": null,
|
23043
23328
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -23118,7 +23403,8 @@
|
|
23118
23403
|
"high_bay_lighting_schedule": null,
|
23119
23404
|
"specialty_lighting_schedule": null,
|
23120
23405
|
"exit_lighting_schedule": null,
|
23121
|
-
"target_illuminance_setpoint":
|
23406
|
+
"target_illuminance_setpoint": 250,
|
23407
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23122
23408
|
"psa_nongeometry_fraction": null,
|
23123
23409
|
"ssa_nongeometry_fraction": null,
|
23124
23410
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -23199,7 +23485,8 @@
|
|
23199
23485
|
"high_bay_lighting_schedule": null,
|
23200
23486
|
"specialty_lighting_schedule": null,
|
23201
23487
|
"exit_lighting_schedule": null,
|
23202
|
-
"target_illuminance_setpoint":
|
23488
|
+
"target_illuminance_setpoint": 400,
|
23489
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23203
23490
|
"psa_nongeometry_fraction": null,
|
23204
23491
|
"ssa_nongeometry_fraction": null,
|
23205
23492
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -23280,7 +23567,8 @@
|
|
23280
23567
|
"high_bay_lighting_schedule": null,
|
23281
23568
|
"specialty_lighting_schedule": null,
|
23282
23569
|
"exit_lighting_schedule": null,
|
23283
|
-
"target_illuminance_setpoint":
|
23570
|
+
"target_illuminance_setpoint": 400,
|
23571
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23284
23572
|
"psa_nongeometry_fraction": null,
|
23285
23573
|
"ssa_nongeometry_fraction": null,
|
23286
23574
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -23361,7 +23649,8 @@
|
|
23361
23649
|
"high_bay_lighting_schedule": null,
|
23362
23650
|
"specialty_lighting_schedule": null,
|
23363
23651
|
"exit_lighting_schedule": null,
|
23364
|
-
"target_illuminance_setpoint":
|
23652
|
+
"target_illuminance_setpoint": 400,
|
23653
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23365
23654
|
"psa_nongeometry_fraction": null,
|
23366
23655
|
"ssa_nongeometry_fraction": null,
|
23367
23656
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -23442,7 +23731,8 @@
|
|
23442
23731
|
"high_bay_lighting_schedule": null,
|
23443
23732
|
"specialty_lighting_schedule": null,
|
23444
23733
|
"exit_lighting_schedule": null,
|
23445
|
-
"target_illuminance_setpoint":
|
23734
|
+
"target_illuminance_setpoint": 250,
|
23735
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23446
23736
|
"psa_nongeometry_fraction": null,
|
23447
23737
|
"ssa_nongeometry_fraction": null,
|
23448
23738
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -23523,7 +23813,8 @@
|
|
23523
23813
|
"high_bay_lighting_schedule": null,
|
23524
23814
|
"specialty_lighting_schedule": null,
|
23525
23815
|
"exit_lighting_schedule": null,
|
23526
|
-
"target_illuminance_setpoint":
|
23816
|
+
"target_illuminance_setpoint": 600,
|
23817
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23527
23818
|
"psa_nongeometry_fraction": null,
|
23528
23819
|
"ssa_nongeometry_fraction": null,
|
23529
23820
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -23604,7 +23895,8 @@
|
|
23604
23895
|
"high_bay_lighting_schedule": null,
|
23605
23896
|
"specialty_lighting_schedule": null,
|
23606
23897
|
"exit_lighting_schedule": null,
|
23607
|
-
"target_illuminance_setpoint":
|
23898
|
+
"target_illuminance_setpoint": 400,
|
23899
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23608
23900
|
"psa_nongeometry_fraction": null,
|
23609
23901
|
"ssa_nongeometry_fraction": null,
|
23610
23902
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -23685,7 +23977,8 @@
|
|
23685
23977
|
"high_bay_lighting_schedule": null,
|
23686
23978
|
"specialty_lighting_schedule": null,
|
23687
23979
|
"exit_lighting_schedule": null,
|
23688
|
-
"target_illuminance_setpoint":
|
23980
|
+
"target_illuminance_setpoint": 250,
|
23981
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23689
23982
|
"psa_nongeometry_fraction": null,
|
23690
23983
|
"ssa_nongeometry_fraction": null,
|
23691
23984
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -23766,7 +24059,8 @@
|
|
23766
24059
|
"high_bay_lighting_schedule": null,
|
23767
24060
|
"specialty_lighting_schedule": null,
|
23768
24061
|
"exit_lighting_schedule": null,
|
23769
|
-
"target_illuminance_setpoint":
|
24062
|
+
"target_illuminance_setpoint": 250,
|
24063
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23770
24064
|
"psa_nongeometry_fraction": null,
|
23771
24065
|
"ssa_nongeometry_fraction": null,
|
23772
24066
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -23847,7 +24141,8 @@
|
|
23847
24141
|
"high_bay_lighting_schedule": null,
|
23848
24142
|
"specialty_lighting_schedule": null,
|
23849
24143
|
"exit_lighting_schedule": null,
|
23850
|
-
"target_illuminance_setpoint":
|
24144
|
+
"target_illuminance_setpoint": 350,
|
24145
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23851
24146
|
"psa_nongeometry_fraction": null,
|
23852
24147
|
"ssa_nongeometry_fraction": null,
|
23853
24148
|
"ventilation_standard": "ASHRAE 62.1-2010 Table 6-4",
|
@@ -23928,7 +24223,8 @@
|
|
23928
24223
|
"high_bay_lighting_schedule": null,
|
23929
24224
|
"specialty_lighting_schedule": null,
|
23930
24225
|
"exit_lighting_schedule": null,
|
23931
|
-
"target_illuminance_setpoint":
|
24226
|
+
"target_illuminance_setpoint": 400,
|
24227
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
23932
24228
|
"psa_nongeometry_fraction": null,
|
23933
24229
|
"ssa_nongeometry_fraction": null,
|
23934
24230
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24009,7 +24305,8 @@
|
|
24009
24305
|
"high_bay_lighting_schedule": null,
|
24010
24306
|
"specialty_lighting_schedule": null,
|
24011
24307
|
"exit_lighting_schedule": null,
|
24012
|
-
"target_illuminance_setpoint":
|
24308
|
+
"target_illuminance_setpoint": 150,
|
24309
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24013
24310
|
"psa_nongeometry_fraction": null,
|
24014
24311
|
"ssa_nongeometry_fraction": null,
|
24015
24312
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24090,7 +24387,8 @@
|
|
24090
24387
|
"high_bay_lighting_schedule": null,
|
24091
24388
|
"specialty_lighting_schedule": null,
|
24092
24389
|
"exit_lighting_schedule": null,
|
24093
|
-
"target_illuminance_setpoint":
|
24390
|
+
"target_illuminance_setpoint": 150,
|
24391
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24094
24392
|
"psa_nongeometry_fraction": null,
|
24095
24393
|
"ssa_nongeometry_fraction": null,
|
24096
24394
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24171,7 +24469,8 @@
|
|
24171
24469
|
"high_bay_lighting_schedule": null,
|
24172
24470
|
"specialty_lighting_schedule": null,
|
24173
24471
|
"exit_lighting_schedule": null,
|
24174
|
-
"target_illuminance_setpoint":
|
24472
|
+
"target_illuminance_setpoint": 1600,
|
24473
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24175
24474
|
"psa_nongeometry_fraction": null,
|
24176
24475
|
"ssa_nongeometry_fraction": null,
|
24177
24476
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24252,7 +24551,8 @@
|
|
24252
24551
|
"high_bay_lighting_schedule": null,
|
24253
24552
|
"specialty_lighting_schedule": null,
|
24254
24553
|
"exit_lighting_schedule": null,
|
24255
|
-
"target_illuminance_setpoint":
|
24554
|
+
"target_illuminance_setpoint": 1000,
|
24555
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24256
24556
|
"psa_nongeometry_fraction": null,
|
24257
24557
|
"ssa_nongeometry_fraction": null,
|
24258
24558
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24333,7 +24633,8 @@
|
|
24333
24633
|
"high_bay_lighting_schedule": null,
|
24334
24634
|
"specialty_lighting_schedule": null,
|
24335
24635
|
"exit_lighting_schedule": null,
|
24336
|
-
"target_illuminance_setpoint":
|
24636
|
+
"target_illuminance_setpoint": 800,
|
24637
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24337
24638
|
"psa_nongeometry_fraction": null,
|
24338
24639
|
"ssa_nongeometry_fraction": null,
|
24339
24640
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24414,7 +24715,8 @@
|
|
24414
24715
|
"high_bay_lighting_schedule": null,
|
24415
24716
|
"specialty_lighting_schedule": null,
|
24416
24717
|
"exit_lighting_schedule": null,
|
24417
|
-
"target_illuminance_setpoint":
|
24718
|
+
"target_illuminance_setpoint": 500,
|
24719
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24418
24720
|
"psa_nongeometry_fraction": null,
|
24419
24721
|
"ssa_nongeometry_fraction": null,
|
24420
24722
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24495,7 +24797,8 @@
|
|
24495
24797
|
"high_bay_lighting_schedule": null,
|
24496
24798
|
"specialty_lighting_schedule": null,
|
24497
24799
|
"exit_lighting_schedule": null,
|
24498
|
-
"target_illuminance_setpoint":
|
24800
|
+
"target_illuminance_setpoint": 150,
|
24801
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24499
24802
|
"psa_nongeometry_fraction": null,
|
24500
24803
|
"ssa_nongeometry_fraction": null,
|
24501
24804
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24576,7 +24879,8 @@
|
|
24576
24879
|
"high_bay_lighting_schedule": null,
|
24577
24880
|
"specialty_lighting_schedule": null,
|
24578
24881
|
"exit_lighting_schedule": null,
|
24579
|
-
"target_illuminance_setpoint":
|
24882
|
+
"target_illuminance_setpoint": 250,
|
24883
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24580
24884
|
"psa_nongeometry_fraction": null,
|
24581
24885
|
"ssa_nongeometry_fraction": null,
|
24582
24886
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24657,7 +24961,8 @@
|
|
24657
24961
|
"high_bay_lighting_schedule": null,
|
24658
24962
|
"specialty_lighting_schedule": null,
|
24659
24963
|
"exit_lighting_schedule": null,
|
24660
|
-
"target_illuminance_setpoint":
|
24964
|
+
"target_illuminance_setpoint": 250,
|
24965
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24661
24966
|
"psa_nongeometry_fraction": null,
|
24662
24967
|
"ssa_nongeometry_fraction": null,
|
24663
24968
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24738,7 +25043,8 @@
|
|
24738
25043
|
"high_bay_lighting_schedule": null,
|
24739
25044
|
"specialty_lighting_schedule": null,
|
24740
25045
|
"exit_lighting_schedule": null,
|
24741
|
-
"target_illuminance_setpoint":
|
25046
|
+
"target_illuminance_setpoint": 200,
|
25047
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24742
25048
|
"psa_nongeometry_fraction": null,
|
24743
25049
|
"ssa_nongeometry_fraction": null,
|
24744
25050
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24819,7 +25125,8 @@
|
|
24819
25125
|
"high_bay_lighting_schedule": null,
|
24820
25126
|
"specialty_lighting_schedule": null,
|
24821
25127
|
"exit_lighting_schedule": null,
|
24822
|
-
"target_illuminance_setpoint":
|
25128
|
+
"target_illuminance_setpoint": 300,
|
25129
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24823
25130
|
"psa_nongeometry_fraction": null,
|
24824
25131
|
"ssa_nongeometry_fraction": null,
|
24825
25132
|
"ventilation_standard": "ASHRAE 62.1-2016 Table 6-1",
|
@@ -24901,6 +25208,7 @@
|
|
24901
25208
|
"specialty_lighting_schedule": null,
|
24902
25209
|
"exit_lighting_schedule": null,
|
24903
25210
|
"target_illuminance_setpoint": null,
|
25211
|
+
"target_illuminance_setpoint_ref": "NECB2020 Table A-8.4.3.2.(2)-A",
|
24904
25212
|
"psa_nongeometry_fraction": null,
|
24905
25213
|
"ssa_nongeometry_fraction": null,
|
24906
25214
|
"ventilation_standard": "N/A",
|