openstudio-standards 0.4.0 → 0.5.0

Sign up to get free protection for your applications and to get access to all the features.
Files changed (378) hide show
  1. checksums.yaml +4 -4
  2. data/LICENSE.md +33 -0
  3. data/data/inventory/thermal_bridging.csv +90 -0
  4. data/data/standards/OpenStudio_Standards-deer-comstock.xlsx +0 -0
  5. data/data/standards/manage_OpenStudio_Standards.rb +1 -1
  6. data/data/standards/test_performance_expected_dd_results.csv +2014 -1891
  7. data/lib/openstudio-standards/btap/analysis.rb +8 -8
  8. data/lib/openstudio-standards/btap/bridging.rb +664 -645
  9. data/lib/openstudio-standards/btap/btap.model.rb +14 -14
  10. data/lib/openstudio-standards/btap/btap.rb +7 -7
  11. data/lib/openstudio-standards/btap/btap_result.rb +1 -1
  12. data/lib/openstudio-standards/btap/economics.rb +23 -23
  13. data/lib/openstudio-standards/btap/envelope.rb +8 -8
  14. data/lib/openstudio-standards/btap/equest.rb +1 -1
  15. data/lib/openstudio-standards/btap/geometry.rb +2 -2
  16. data/lib/openstudio-standards/btap/mpc.rb +7 -7
  17. data/lib/openstudio-standards/btap/schedules.rb +1 -1
  18. data/lib/openstudio-standards/btap/simmanager.rb +4 -4
  19. data/lib/openstudio-standards/btap/spaceloads.rb +26 -26
  20. data/lib/openstudio-standards/btap/utilities.rb +6 -6
  21. data/lib/openstudio-standards/btap/vintagizer.rb +1 -1
  22. data/lib/openstudio-standards/constructions/information.rb +83 -0
  23. data/lib/openstudio-standards/constructions/materials/modify.rb +72 -0
  24. data/lib/openstudio-standards/constructions/modify.rb +80 -0
  25. data/lib/openstudio-standards/create_typical/create_typical.rb +983 -0
  26. data/lib/openstudio-standards/create_typical/enumerations.rb +484 -0
  27. data/lib/openstudio-standards/create_typical/space_type_blend.rb +791 -0
  28. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +494 -0
  29. data/lib/openstudio-standards/daylighting/space.rb +47 -0
  30. data/lib/openstudio-standards/geometry/create.rb +801 -0
  31. data/lib/openstudio-standards/geometry/create_bar.rb +2170 -0
  32. data/lib/openstudio-standards/geometry/information.rb +462 -0
  33. data/lib/openstudio-standards/geometry/modify.rb +48 -0
  34. data/lib/openstudio-standards/hvac/air_loop/information.rb +79 -0
  35. data/lib/openstudio-standards/hvac/cbecs_hvac.rb +616 -0
  36. data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +91 -0
  37. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
  38. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +1 -1
  39. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  40. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +1 -1
  41. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  42. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +2 -2
  43. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +1 -1
  44. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  45. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -36
  46. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +1 -1
  47. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  48. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -36
  49. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +3 -3
  50. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +1 -1
  51. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
  52. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +1 -1
  53. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +1 -1
  54. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +1 -1
  55. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +1 -1
  56. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  57. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  58. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +7 -7
  59. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +8 -8
  60. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +14 -14
  61. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +9 -9
  62. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +16 -16
  63. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +7 -7
  64. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +8 -8
  65. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +8 -8
  66. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +11 -11
  67. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +7 -7
  68. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +9 -9
  69. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +8 -8
  70. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +11 -11
  71. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +9 -9
  72. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +19 -19
  73. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +10 -10
  74. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +13 -13
  75. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +6 -6
  76. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +6 -6
  77. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -9
  78. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +8 -8
  79. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +8 -8
  80. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +8 -8
  81. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +8 -8
  82. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +11 -11
  83. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +10 -10
  84. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +19 -19
  85. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +18 -18
  86. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +6 -6
  87. data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +957 -957
  88. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +1 -1
  89. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +1 -1
  90. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +84 -16
  91. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
  92. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +1 -1
  93. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +61 -10
  94. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +1 -1
  95. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
  96. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +1 -1
  97. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -1
  98. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -1
  99. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +1 -1
  100. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +1 -1
  101. data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +2 -2
  102. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +4 -4
  103. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +4 -4
  104. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +43 -30
  105. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +1 -1
  106. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +18 -11
  107. data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +1 -1
  108. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +774 -117
  109. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +340 -481
  110. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +3 -3
  111. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +3 -3
  112. data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +22 -22
  113. data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
  114. data/lib/openstudio-standards/qaqc/calibration.rb +131 -0
  115. data/lib/openstudio-standards/qaqc/create_results.rb +983 -0
  116. data/lib/openstudio-standards/qaqc/envelope.rb +399 -0
  117. data/lib/openstudio-standards/qaqc/eui.rb +213 -0
  118. data/lib/openstudio-standards/qaqc/hvac.rb +1943 -0
  119. data/lib/openstudio-standards/qaqc/internal_loads.rb +568 -0
  120. data/lib/openstudio-standards/qaqc/reporting.rb +141 -0
  121. data/lib/openstudio-standards/qaqc/schedules.rb +129 -0
  122. data/lib/openstudio-standards/qaqc/service_water_heating.rb +273 -0
  123. data/lib/openstudio-standards/qaqc/weather_files.rb +497 -0
  124. data/lib/openstudio-standards/qaqc/zone_conditions.rb +278 -0
  125. data/lib/openstudio-standards/schedules/create.rb +364 -0
  126. data/lib/openstudio-standards/schedules/information.rb +169 -0
  127. data/lib/openstudio-standards/schedules/modify.rb +445 -0
  128. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +110 -71
  129. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
  130. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +4 -4
  131. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +2 -1
  132. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +16 -10
  133. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -4
  134. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +1 -1
  135. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
  136. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +4 -4
  137. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +1 -1
  138. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +5 -5
  139. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +1 -1
  140. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
  141. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
  142. data/lib/openstudio-standards/standards/Standards.Construction.rb +17 -18
  143. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +6 -6
  144. data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +1 -1
  145. data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +1 -1
  146. data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +1 -1
  147. data/lib/openstudio-standards/standards/Standards.Fan.rb +6 -12
  148. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -2
  149. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +1 -1
  150. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +1 -1
  151. data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +3 -3
  152. data/lib/openstudio-standards/standards/Standards.Model.rb +411 -261
  153. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -2
  154. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -29
  155. data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -2
  156. data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -2
  157. data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +14 -14
  158. data/lib/openstudio-standards/standards/Standards.Space.rb +37 -30
  159. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +38 -29
  160. data/lib/openstudio-standards/standards/Standards.SubSurface.rb +7 -7
  161. data/lib/openstudio-standards/standards/Standards.Surface.rb +13 -13
  162. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +109 -66
  163. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +11 -4
  164. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +6 -6
  165. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
  166. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +1 -1
  167. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +1 -1
  168. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +1 -1
  169. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +4 -4
  170. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  171. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +4 -4
  172. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +4 -4
  173. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  174. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +1 -1
  175. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +5 -21
  176. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +4 -4
  177. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
  178. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -1
  179. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +36 -4
  180. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  181. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +1 -1
  182. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +4 -4
  183. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -1
  184. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb +26 -0
  185. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +53 -10
  186. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  187. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +1 -1
  188. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +6 -6
  189. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +2 -2
  190. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb +26 -0
  191. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +211 -211
  192. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +14 -14
  193. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +4 -4
  194. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
  195. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +1 -1
  196. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +14 -14
  197. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +4 -4
  198. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
  199. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +1 -1
  200. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +6 -6
  201. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  202. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +1 -1
  203. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
  204. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +4 -4
  205. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +6 -6
  206. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  207. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +1 -1
  208. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
  209. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +4 -4
  210. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +22 -28
  211. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
  212. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat.rb +2 -2
  213. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater.rb +1 -74
  214. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +7 -59
  215. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +1 -1
  216. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
  217. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +1 -1
  218. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +1 -1
  219. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -21
  220. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb +101 -0
  221. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +1 -1
  222. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +1 -1
  223. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume.rb +1 -1
  224. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat.rb +1 -1
  225. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +643 -526
  226. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface.rb +8 -2
  227. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +17 -77
  228. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +74 -16
  229. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +96 -44
  230. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Surface.rb +6 -6
  231. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone.rb +18 -6
  232. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent.rb +1 -1
  233. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +328 -74
  234. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +0 -118
  235. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +2 -1
  236. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_rejection.json +1 -1
  237. data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md +35 -0
  238. data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_plug_load_measures.md +1 -1
  239. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +228 -0
  240. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +131 -0
  241. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_space.csv +1 -1
  242. data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +5 -5
  243. data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -1
  244. data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +1 -1
  245. data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +1 -1
  246. data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +1 -1
  247. data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +1 -1
  248. data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +109 -27
  249. data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
  250. data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.economizers.json +246 -4
  251. data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +246 -4
  252. data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.economizers.json +246 -4
  253. data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.ThermalZone.rb +18 -18
  254. data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.economizers.json +246 -4
  255. data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.ThermalZone.rb +18 -18
  256. data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.economizers.json +246 -4
  257. data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.ThermalZone.rb +18 -18
  258. data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.economizers.json +248 -6
  259. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +3 -3
  260. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.ThermalZone.rb +18 -18
  261. data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.economizers.json +248 -6
  262. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +3 -3
  263. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.ThermalZone.rb +18 -18
  264. data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.economizers.json +248 -6
  265. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +3 -3
  266. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.ThermalZone.rb +18 -18
  267. data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.economizers.json +248 -6
  268. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +18 -5
  269. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
  270. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +3 -3
  271. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.ThermalZone.rb +18 -18
  272. data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.economizers.json +248 -6
  273. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +3 -3
  274. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
  275. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +3 -3
  276. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.economizers.json +248 -6
  277. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps.json +2 -2
  278. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +3 -3
  279. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
  280. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +3 -3
  281. data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.economizers.json +248 -6
  282. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +3 -3
  283. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
  284. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +3 -3
  285. data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.economizers.json +248 -6
  286. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +3 -3
  287. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
  288. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +3 -3
  289. data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json +260 -0
  290. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +3 -3
  291. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
  292. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +3 -3
  293. data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.economizers.json +248 -6
  294. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +3 -3
  295. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
  296. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +3 -3
  297. data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.economizers.json +248 -6
  298. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +3 -3
  299. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
  300. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +3 -3
  301. data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.economizers.json +248 -6
  302. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +3 -3
  303. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
  304. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +3 -3
  305. data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.economizers.json +248 -6
  306. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +3 -3
  307. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
  308. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +3 -3
  309. data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.economizers.json +248 -6
  310. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +3 -3
  311. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
  312. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +3 -3
  313. data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.economizers.json +248 -6
  314. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +3 -3
  315. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
  316. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +3 -3
  317. data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.economizers.json +246 -4
  318. data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +447 -223
  319. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +1 -1
  320. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +447 -223
  321. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +5 -2
  322. data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json +25 -0
  323. data/lib/openstudio-standards/standards/necb/ECMS/data/chillers.json +44 -0
  324. data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +225 -0
  325. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +2 -2
  326. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +193 -73
  327. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +1 -1
  328. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +10 -4
  329. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +7 -7
  330. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +4 -5
  331. data/lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json +32 -0
  332. data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +1 -1
  333. data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +36 -0
  334. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -7
  335. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm +47587 -0
  336. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm +49764 -0
  337. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Warehouse.osm +283 -297
  338. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_type_unit_definitions.txt +2 -1
  339. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +447 -223
  340. data/lib/openstudio-standards/standards/necb/NECB2011/data/standards_data.rb +3 -3
  341. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +1 -1
  342. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +49 -27
  343. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +400 -202
  344. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -4
  345. data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +637 -318
  346. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +18 -1
  347. data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +3 -3
  348. data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +637 -318
  349. data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -1
  350. data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +3 -3
  351. data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +1 -1
  352. data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +615 -307
  353. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +4 -4
  354. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +10 -5
  355. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +1 -1
  356. data/lib/openstudio-standards/utilities/assertion.rb +128 -0
  357. data/lib/openstudio-standards/utilities/logging.rb +2 -3
  358. data/lib/openstudio-standards/utilities/object_info.rb +39 -18
  359. data/lib/openstudio-standards/utilities/schedule_translator.rb +8 -6
  360. data/lib/openstudio-standards/utilities/simulation.rb +24 -11
  361. data/lib/openstudio-standards/utilities/sqlfile.rb +10 -5
  362. data/lib/openstudio-standards/version.rb +1 -1
  363. data/lib/openstudio-standards/weather/Weather.Model.rb +8 -9
  364. data/lib/openstudio-standards/weather/Weather.stat_file.rb +3 -3
  365. data/lib/openstudio-standards/weather/information.rb +35 -0
  366. data/lib/openstudio-standards.rb +69 -5
  367. metadata +54 -18
  368. data/License.txt +0 -65
  369. data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
  370. data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +0 -59
  371. data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb +0 -13
  372. data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +0 -36
  373. data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +0 -898
  374. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +0 -126
  375. data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +0 -356
  376. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +0 -35
  377. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb +0 -110
  378. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb +0 -5
@@ -4,7 +4,7 @@ class Standard
4
4
  # Sets the fan power of a PIU fan based on the W/cfm specified in the standard.
5
5
  #
6
6
  # @param air_terminal_single_duct_parallel_piu_reheat [OpenStudio::Model::AirTerminalSingleDuctParallelPIUReheat] air terminal object
7
- # @return [Bool] returns true if successful, false if not
7
+ # @return [Boolean] returns true if successful, false if not
8
8
  def air_terminal_single_duct_parallel_piu_reheat_apply_prm_baseline_fan_power(air_terminal_single_duct_parallel_piu_reheat)
9
9
  OpenStudio.logFree(OpenStudio::Debug, 'openstudio.standards.AirTerminalSingleDuctParallelPIUReheat', "Setting PIU fan power for #{air_terminal_single_duct_parallel_piu_reheat.name}.")
10
10
 
@@ -72,7 +72,7 @@ class Standard
72
72
  # means that the secondary fan will be on when the primary air
73
73
  # flow is at the minimum flow fraction.
74
74
  #
75
- # @return [Float] returns nil or a float representing the fraction
75
+ # @return [Double] returns nil or a float representing the fraction
76
76
  def air_terminal_single_duct_parallel_piu_reheat_fan_on_flow_fraction
77
77
  return nil
78
78
  end
@@ -90,7 +90,7 @@ class Standard
90
90
  #
91
91
  # @param air_terminal_single_duct_parallel_piu_reheat [OpenStudio::Model::AirTerminalSingleDuctParallelPIUReheat] the air terminal object
92
92
  # @param zone_min_oa [Double] the zone outdoor air flow rate, in m^3/s.
93
- # @return [Bool] returns true if successful, false if not
93
+ # @return [Boolean] returns true if successful, false if not
94
94
  def air_terminal_single_duct_parallel_piu_reheat_apply_minimum_primary_airflow_fraction(air_terminal_single_duct_parallel_piu_reheat, zone_min_oa = nil)
95
95
  # Minimum primary air flow
96
96
  min_primary_airflow_frac = air_terminal_single_duct_parallel_reheat_piu_minimum_primary_airflow_fraction(air_terminal_single_duct_parallel_piu_reheat)
@@ -9,9 +9,9 @@ class Standard
9
9
  # @param zone_min_oa [Double] the zone outdoor air flow rate, in m^3/s.
10
10
  # If supplied, this will be set as a minimum limit in addition to the minimum
11
11
  # damper position. EnergyPlus will use the larger of the two values during sizing.
12
- # @param has_ddc [Bool] whether or not there is DDC control of the VAV terminal,
12
+ # @param has_ddc [Boolean] whether or not there is DDC control of the VAV terminal,
13
13
  # which impacts the minimum damper position requirement.
14
- # @return [Bool] returns true if successful, false if not
14
+ # @return [Boolean] returns true if successful, false if not
15
15
  # @todo remove exception where older vintages don't have minimum positions adjusted.
16
16
  def air_terminal_single_duct_vav_reheat_apply_minimum_damper_position(air_terminal_single_duct_vav_reheat, zone_min_oa = nil, has_ddc = true)
17
17
  # Minimum damper position
@@ -34,7 +34,7 @@ class Standard
34
34
  # Defaults to 30%
35
35
  #
36
36
  # @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
37
- # @param has_ddc [Bool] whether or not there is DDC control of the VAV terminal in question
37
+ # @param has_ddc [Boolean] whether or not there is DDC control of the VAV terminal in question
38
38
  # @return [Double] minimum damper position
39
39
  def air_terminal_single_duct_vav_reheat_minimum_damper_position(air_terminal_single_duct_vav_reheat, has_ddc = false)
40
40
  min_damper_position = 0.3
@@ -44,7 +44,7 @@ class Standard
44
44
  # Sets the capacity of the reheat coil based on the minimum flow fraction, and the maximum flow rate.
45
45
  #
46
46
  # @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
47
- # @return [Bool] returns true if successful, false if not
47
+ # @return [Boolean] returns true if successful, false if not
48
48
  def air_terminal_single_duct_vav_reheat_set_heating_cap(air_terminal_single_duct_vav_reheat)
49
49
  flow_rate_fraction = 0.0
50
50
  if air_terminal_single_duct_vav_reheat.constantMinimumAirFlowFraction.is_initialized
@@ -74,6 +74,7 @@ class Standard
74
74
  # Finds lookup object in standards and return minimum thermal efficiency
75
75
  #
76
76
  # @param boiler_hot_water [OpenStudio::Model::BoilerHotWater] hot water boiler object
77
+ # @param rename [Boolean] if true, rename the boiler to include the new capacity and efficiency
77
78
  # @return [Double] minimum thermal efficiency
78
79
  def boiler_hot_water_standard_minimum_thermal_efficiency(boiler_hot_water, rename = false)
79
80
  # Get the boiler properties
@@ -130,7 +131,7 @@ class Standard
130
131
  # Applies the standard efficiency ratings and typical performance curves to this object.
131
132
  #
132
133
  # @param boiler_hot_water [OpenStudio::Model::BoilerHotWater] hot water boiler object
133
- # @return [Bool] returns true if successful, false if not
134
+ # @return [Boolean] returns true if successful, false if not
134
135
  def boiler_hot_water_apply_efficiency_and_curves(boiler_hot_water)
135
136
  successfully_set_all_properties = false
136
137
 
@@ -4,7 +4,7 @@ class Standard
4
4
  # Finds the search criteria
5
5
  #
6
6
  # @param chiller_electric_eir [OpenStudio::Model::ChillerElectricEIR] chiller object
7
- # @return [hash] has for search criteria to be used for find object
7
+ # @return [Hash] has for search criteria to be used for find object
8
8
  def chiller_electric_eir_find_search_criteria(chiller_electric_eir)
9
9
  search_criteria = {}
10
10
  search_criteria['template'] = template
@@ -36,14 +36,20 @@ class Standard
36
36
  condenser_type = 'WithCondenser' if absorption_type.nil?
37
37
  end
38
38
  elsif cooling_type == 'WaterCooled'
39
- if name.include?('Reciprocating')
40
- compressor_type = 'Reciprocating'
41
- elsif name.include?('Rotary Screw')
42
- compressor_type = 'Rotary Screw'
43
- elsif name.include?('Scroll')
44
- compressor_type = 'Scroll'
45
- elsif name.include?('Centrifugal')
46
- compressor_type = 'Centrifugal'
39
+ # use the chiller additional properties compressor type if defined
40
+ if chiller_electric_eir.additionalProperties.hasFeature('compressor_type')
41
+ compressor_type = chiller_electric_eir.additionalProperties.getFeatureAsString('compressor_type').get
42
+ else
43
+ # try to lookup by chiller name
44
+ if name.include?('Reciprocating')
45
+ compressor_type = 'Reciprocating'
46
+ elsif name.include?('Rotary Screw')
47
+ compressor_type = 'Rotary Screw'
48
+ elsif name.include?('Scroll')
49
+ compressor_type = 'Scroll'
50
+ elsif name.include?('Centrifugal')
51
+ compressor_type = 'Centrifugal'
52
+ end
47
53
  end
48
54
  end
49
55
  unless condenser_type.nil?
@@ -102,7 +108,7 @@ class Standard
102
108
  #
103
109
  # @param chiller_electric_eir [OpenStudio::Model::ChillerElectricEIR] chiller object
104
110
  # @param clg_tower_objs [Array] cooling towers, currently unused
105
- # @return [Bool] returns true if successful, false if not
111
+ # @return [Boolean] returns true if successful, false if not
106
112
  # @todo remove clg_tower_objs parameter if unused
107
113
  def chiller_electric_eir_apply_efficiency_and_curves(chiller_electric_eir, clg_tower_objs)
108
114
  chillers = standards_data['chillers']
@@ -6,7 +6,7 @@ class Standard
6
6
  # Finds capacity in W
7
7
  #
8
8
  # @param coil_cooling_dx_single_speed [OpenStudio::Model::CoilCoolingDXSingleSpeed] coil cooling dx single speed object
9
- # @param necb_ref_hp [Bool] for compatability with NECB ruleset only.
9
+ # @param necb_ref_hp [Boolean] for compatability with NECB ruleset only.
10
10
  # @return [Double] capacity in W to be used for find object
11
11
  def coil_cooling_dx_single_speed_find_capacity(coil_cooling_dx_single_speed, necb_ref_hp = false)
12
12
  capacity_w = nil
@@ -42,8 +42,8 @@ class Standard
42
42
  # Finds lookup object in standards and return efficiency
43
43
  #
44
44
  # @param coil_cooling_dx_single_speed [OpenStudio::Model::CoilCoolingDXSingleSpeed] coil cooling dx single speed object
45
- # @param rename [Bool] if true, object will be renamed to include capacity and efficiency level
46
- # @param necb_ref_hp [Bool] for compatability with NECB ruleset only.
45
+ # @param rename [Boolean] if true, object will be renamed to include capacity and efficiency level
46
+ # @param necb_ref_hp [Boolean] for compatability with NECB ruleset only.
47
47
  # @return [Double] full load efficiency (COP)
48
48
  def coil_cooling_dx_single_speed_standard_minimum_cop(coil_cooling_dx_single_speed, rename = false, necb_ref_hp = false)
49
49
  search_criteria = coil_dx_find_search_criteria(coil_cooling_dx_single_speed, necb_ref_hp)
@@ -173,7 +173,7 @@ class Standard
173
173
  #
174
174
  # @param coil_cooling_dx_single_speed [OpenStudio::Model::CoilCoolingDXSingleSpeed] coil cooling dx single speed object
175
175
  # @param sql_db_vars_map [Hash] hash map
176
- # @param necb_ref_hp [Bool] for compatability with NECB ruleset only.
176
+ # @param necb_ref_hp [Boolean] for compatability with NECB ruleset only.
177
177
  # @return [Hash] hash of coil objects
178
178
  def coil_cooling_dx_single_speed_apply_efficiency_and_curves(coil_cooling_dx_single_speed, sql_db_vars_map, necb_ref_hp = false)
179
179
  successfully_set_all_properties = true
@@ -24,7 +24,7 @@ class Standard
24
24
  # Finds lookup object in standards and return efficiency
25
25
  #
26
26
  # @param coil_cooling_dx_two_speed [OpenStudio::Model::CoilCoolingDXTwoSpeed] coil cooling dx two speed object
27
- # @param rename [Bool] if true, object will be renamed to include capacity and efficiency level
27
+ # @param rename [Boolean] if true, object will be renamed to include capacity and efficiency level
28
28
  # @return [Double] full load efficiency (COP)
29
29
  def coil_cooling_dx_two_speed_standard_minimum_cop(coil_cooling_dx_two_speed, rename = false)
30
30
  search_criteria = coil_dx_find_search_criteria(coil_cooling_dx_two_speed)
@@ -22,7 +22,7 @@ class Standard
22
22
  # Finds lookup object in standards and return efficiency
23
23
  #
24
24
  # @param coil_cooling_water_to_air_heat_pump [OpenStudio::Model::CoilCoolingWaterToAirHeatPumpEquationFit] coil cooling object
25
- # @param rename [Bool] if true, object will be renamed to include capacity and efficiency level
25
+ # @param rename [Boolean] if true, object will be renamed to include capacity and efficiency level
26
26
  # @return [Double] full load efficiency (COP)
27
27
  def coil_cooling_water_to_air_heat_pump_standard_minimum_cop(coil_cooling_water_to_air_heat_pump, rename = false, computer_room_air_conditioner = false)
28
28
  search_criteria = {}
@@ -48,7 +48,7 @@ module CoilDX
48
48
  #
49
49
  # @param coil_dx [OpenStudio::Model::StraightComponent] coil cooling object, allowable types:
50
50
  # CoilCoolingDXSingleSpeed, CoilCoolingDXTwoSpeed, CoilCoolingDXMultiSpeed
51
- # @return [Bool] returns true if it is a heat pump, false if not
51
+ # @return [Boolean] returns true if it is a heat pump, false if not
52
52
  def coil_dx_heat_pump?(coil_dx)
53
53
  heat_pump = false
54
54
 
@@ -84,7 +84,7 @@ module CoilDX
84
84
  #
85
85
  # @param coil_dx [OpenStudio::Model::StraightComponent] coil cooling object, allowable types:
86
86
  # CoilCoolingDXSingleSpeed, CoilCoolingDXTwoSpeed, CoilCoolingDXMultiSpeed
87
- # @param necb_ref_hp [Bool] for compatability with NECB ruleset only.
87
+ # @param necb_ref_hp [Boolean] for compatability with NECB ruleset only.
88
88
  # @return [String] the heating type
89
89
  def coil_dx_heating_type(coil_dx, necb_ref_hp = false)
90
90
  htg_type = nil
@@ -160,8 +160,8 @@ module CoilDX
160
160
  #
161
161
  # @param coil_dx [OpenStudio::Model::StraightComponent] coil cooling object, allowable types:
162
162
  # CoilCoolingDXSingleSpeed, CoilCoolingDXTwoSpeed, CoilCoolingDXMultiSpeed
163
- # @param necb_ref_hp [Bool] for compatability with NECB ruleset only.
164
- # @return [hash] has for search criteria to be used for find object
163
+ # @param necb_ref_hp [Boolean] for compatability with NECB ruleset only.
164
+ # @return [Hash] has for search criteria to be used for find object
165
165
  def coil_dx_find_search_criteria(coil_dx, necb_ref_hp = false)
166
166
  search_criteria = {}
167
167
  search_criteria['template'] = template
@@ -4,7 +4,7 @@ class Standard
4
4
  # Applies the standard efficiency ratings and typical performance curves to this object.
5
5
  #
6
6
  # @param coil_heating_dx_multi_speed [OpenStudio::Model::CoilHeatingDXMultiSpeed] coil heating dx multi speed object
7
- # @return [Bool] returns true if successful, false if not
7
+ # @return [Boolean] returns true if successful, false if not
8
8
  def coil_heating_dx_multi_speed_apply_efficiency_and_curves(coil_heating_dx_multi_speed, sql_db_vars_map)
9
9
  successfully_set_all_properties = true
10
10
 
@@ -6,7 +6,7 @@ class Standard
6
6
  # Finds capacity in W. This is the cooling capacity of the paired DX cooling coil.
7
7
  #
8
8
  # @param coil_heating_dx_single_speed [OpenStudio::Model::CoilHeatingDXSingleSpeed] coil heating dx single speed object
9
- # @param necb_ref_hp [Bool] for compatability with NECB ruleset only.
9
+ # @param necb_ref_hp [Boolean] for compatability with NECB ruleset only.
10
10
  # @return [Double] capacity in W to be used for find object
11
11
  def coil_heating_dx_single_speed_find_capacity(coil_heating_dx_single_speed, necb_ref_hp = false)
12
12
  capacity_w = nil
@@ -104,8 +104,8 @@ class Standard
104
104
  # Finds lookup object in standards and return efficiency
105
105
  #
106
106
  # @param coil_heating_dx_single_speed [OpenStudio::Model::CoilHeatingDXSingleSpeed] coil heating dx single speed object
107
- # @param rename [Bool] if true, object will be renamed to include capacity and efficiency level
108
- # @param necb_ref_hp [Bool] for compatability with NECB ruleset only.
107
+ # @param rename [Boolean] if true, object will be renamed to include capacity and efficiency level
108
+ # @param necb_ref_hp [Boolean] for compatability with NECB ruleset only.
109
109
  # @return [Double] full load efficiency (COP)
110
110
  def coil_heating_dx_single_speed_standard_minimum_cop(coil_heating_dx_single_speed, rename = false, necb_ref_hp = false)
111
111
  # find ac properties
@@ -129,7 +129,7 @@ class Standard
129
129
  end
130
130
 
131
131
  # If PTHP, use equations
132
- if sub_category == 'PTHP'
132
+ if sub_category == 'PTHP' && !ac_props['pthp_cop_coefficient_1'].nil? && !ac_props['pthp_cop_coefficient_2'].nil?
133
133
  pthp_cop_coeff_1 = ac_props['pthp_cop_coefficient_1']
134
134
  pthp_cop_coeff_2 = ac_props['pthp_cop_coefficient_2']
135
135
  # TABLE 6.8.1D
@@ -181,7 +181,7 @@ class Standard
181
181
  #
182
182
  # @param coil_heating_dx_single_speed [OpenStudio::Model::CoilHeatingDXSingleSpeed] coil heating dx single speed object
183
183
  # @param sql_db_vars_map [Hash] hash map
184
- # @param necb_ref_hp [Bool] for compatability with NECB ruleset only.
184
+ # @param necb_ref_hp [Boolean] for compatability with NECB ruleset only.
185
185
  # @return [Hash] hash of coil objects
186
186
  def coil_heating_dx_single_speed_apply_efficiency_and_curves(coil_heating_dx_single_speed, sql_db_vars_map, necb_ref_hp = false)
187
187
  successfully_set_all_properties = true
@@ -4,7 +4,7 @@ class Standard
4
4
  # Applies the standard efficiency ratings to CoilHeatingGas.
5
5
  #
6
6
  # @param coil_heating_gas [OpenStudio::Model::CoilHeatingGas] coil heating gas object
7
- # @return [Bool] returns true if successful, false if not
7
+ # @return [Boolean] returns true if successful, false if not
8
8
  def coil_heating_gas_apply_efficiency_and_curves(coil_heating_gas)
9
9
  successfully_set_all_properties = false
10
10
  # Initialize search criteria
@@ -19,7 +19,7 @@ class Standard
19
19
  # Applies the standard efficiency ratings and typical performance curves to this object.
20
20
  #
21
21
  # @param coil_heating_gas_multi_stage [OpenStudio::Model::CoilHeatingGasMultiStage] coil heating gas multi stage object
22
- # @return [Bool] returns true if successful, false if not
22
+ # @return [Boolean] returns true if successful, false if not
23
23
  def coil_heating_gas_multi_stage_apply_efficiency_and_curves(coil_heating_gas_multi_stage)
24
24
  successfully_set_all_properties = true
25
25
 
@@ -88,7 +88,7 @@ class Standard
88
88
  # Finds lookup object in standards and return efficiency
89
89
  #
90
90
  # @param coil_heating_water_to_air_heat_pump [OpenStudio::Model::CoilHeatingWaterToAirHeatPumpEquationFit] coil heating object
91
- # @param rename [Bool] if true, object will be renamed to include capacity and efficiency level
91
+ # @param rename [Boolean] if true, object will be renamed to include capacity and efficiency level
92
92
  # @return [Double] full load efficiency (COP)
93
93
  def coil_heating_water_to_air_heat_pump_standard_minimum_cop(coil_heating_water_to_air_heat_pump, rename = false)
94
94
  search_criteria = {}
@@ -12,11 +12,11 @@ class Standard
12
12
  # 'ExteriorRoof', 'Skylight', 'TubularDaylightDome', 'TubularDaylightDiffuser', 'ExteriorFloor',
13
13
  # 'ExteriorWall', 'ExteriorWindow', 'ExteriorDoor', 'GlassDoor', 'OverheadDoor', 'GroundContactFloor',
14
14
  # 'GroundContactWall', 'GroundContactRoof'
15
- # @param target_includes_int_film_coefficients [Bool] if true, subtracts off standard film interior coefficients from your
15
+ # @param target_includes_int_film_coefficients [Boolean] if true, subtracts off standard film interior coefficients from your
16
16
  # target_u_value before modifying insulation thickness. Film values from 90.1-2010 A9.4.1 Air Films
17
- # @param target_includes_ext_film_coefficients [Bool] if true, subtracts off standard exterior film coefficients from your
17
+ # @param target_includes_ext_film_coefficients [Boolean] if true, subtracts off standard exterior film coefficients from your
18
18
  # target_u_value before modifying insulation thickness. Film values from 90.1-2010 A9.4.1 Air Films
19
- # @return [Bool] returns true if successful, false if not
19
+ # @return [Boolean] returns true if successful, false if not
20
20
  # @todo Put in Phlyroy's logic for inferring the insulation layer of a construction
21
21
  def construction_set_u_value(construction, target_u_value_ip, insulation_layer_name = nil, intended_surface_type = 'ExteriorWall', target_includes_int_film_coefficients, target_includes_ext_film_coefficients)
22
22
  OpenStudio.logFree(OpenStudio::Debug, 'openstudio.standards.Construction', "Setting U-Value for #{construction.name}.")
@@ -134,11 +134,11 @@ class Standard
134
134
  # 'ExteriorRoof', 'Skylight', 'TubularDaylightDome', 'TubularDaylightDiffuser', 'ExteriorFloor',
135
135
  # 'ExteriorWall', 'ExteriorWindow', 'ExteriorDoor', 'GlassDoor', 'OverheadDoor', 'GroundContactFloor',
136
136
  # 'GroundContactWall', 'GroundContactRoof'
137
- # @param target_includes_int_film_coefficients [Bool] if true, subtracts off standard film interior coefficients from your
137
+ # @param target_includes_int_film_coefficients [Boolean] if true, subtracts off standard film interior coefficients from your
138
138
  # target_u_value before modifying insulation thickness. Film values from 90.1-2010 A9.4.1 Air Films
139
- # @param target_includes_ext_film_coefficients [Bool] if true, subtracts off standard exterior film coefficients from your
139
+ # @param target_includes_ext_film_coefficients [Boolean] if true, subtracts off standard exterior film coefficients from your
140
140
  # target_u_value before modifying insulation thickness. Film values from 90.1-2010 A9.4.1 Air Films
141
- # @return [Bool] returns true if successful, false if not
141
+ # @return [Boolean] returns true if successful, false if not
142
142
  def construction_set_glazing_u_value(construction, target_u_value_ip, intended_surface_type = 'ExteriorWall', target_includes_int_film_coefficients, target_includes_ext_film_coefficients)
143
143
  OpenStudio.logFree(OpenStudio::Debug, 'openstudio.standards.Construction', "Setting U-Value for #{construction.name}.")
144
144
 
@@ -219,7 +219,7 @@ class Standard
219
219
  #
220
220
  # @param construction [OpenStudio::Model::Construction] construction object
221
221
  # @param target_shgc [Double] Solar Heat Gain Coefficient
222
- # @return [Bool] returns true if successful, false if not
222
+ # @return [Boolean] returns true if successful, false if not
223
223
  def construction_set_glazing_shgc(construction, target_shgc)
224
224
  OpenStudio.logFree(OpenStudio::Debug, 'openstudio.standards.Construction', "Setting SHGC for #{construction.name}.")
225
225
 
@@ -244,7 +244,7 @@ class Standard
244
244
  # as indicated by having a single layer of type SimpleGlazing.
245
245
  #
246
246
  # @param construction [OpenStudio::Model::Construction] construction object
247
- # @return [Bool] returns true if it is a simple glazing, false if not
247
+ # @return [Boolean] returns true if it is a simple glazing, false if not
248
248
  def construction_simple_glazing?(construction)
249
249
  # Not simple if more than 1 layer
250
250
  if construction.layers.length > 1
@@ -269,7 +269,7 @@ class Standard
269
269
  # @param construction [OpenStudio::Model::Construction] construction object
270
270
  # @param target_f_factor_ip [Double] F-Factor
271
271
  # @param insulation_layer_name [String] The name of the insulation layer in this construction
272
- # @return [Bool] returns true if successful, false if not
272
+ # @return [Boolean] returns true if successful, false if not
273
273
  def construction_set_slab_f_factor(construction, target_f_factor_ip, insulation_layer_name = nil)
274
274
  # Regression from table A6.3 unheated, fully insulated slab
275
275
  r_value_ip = 1.0248 * target_f_factor_ip**-2.186
@@ -289,7 +289,7 @@ class Standard
289
289
  # @param construction [OpenStudio::Model::FFactorGroundFloorConstruction] OpenStudio F-factor construction object
290
290
  # @param target_f_factor_ip [Float] Targeted F-Factor in IP units
291
291
  # @param surface [OpenStudio::Model::Surface] OpenStudio surface object
292
- # @return [Bool] returns true if successful, false if not
292
+ # @return [Boolean] returns true if successful, false if not
293
293
  def construction_set_surface_slab_f_factor(construction, target_f_factor_ip, surface)
294
294
  # Get space associated with surface
295
295
  space = surface.space.get
@@ -325,7 +325,7 @@ class Standard
325
325
  # @param construction [OpenStudio::Model::Construction] construction object
326
326
  # @param target_c_factor_ip [Double] C-Factor
327
327
  # @param insulation_layer_name [String] The name of the insulation layer in this construction
328
- # @return [Bool] returns true if successful, false if not
328
+ # @return [Boolean] returns true if successful, false if not
329
329
  def construction_set_underground_wall_c_factor(construction, target_c_factor_ip, insulation_layer_name = nil)
330
330
  # Regression from table A4.2 continuous exterior insulation
331
331
  r_value_ip = 0.775 * target_c_factor_ip**-1.067
@@ -345,7 +345,7 @@ class Standard
345
345
  # @param construction [OpenStudio::Model::CFactorUndergroundWallConstruction] OpenStudio C-factor construction object
346
346
  # @param target_c_factor_ip [Float] Targeted C-Factor in IP units
347
347
  # @param surface [OpenStudio::Model::Surface] OpenStudio surface object
348
- # @return [Bool] returns true if successful, false if not
348
+ # @return [Boolean] returns true if successful, false if not
349
349
  def construction_set_surface_underground_wall_c_factor(construction, target_c_factor_ip, surface)
350
350
  # Get space associated with surface
351
351
  space = surface.space.get
@@ -529,8 +529,7 @@ class Standard
529
529
  # Calculate the fenestration U-Factor base on the glass, frame,
530
530
  # and divider performance and area calculated by EnergyPlus.
531
531
  #
532
- # @param [OpenStudio:Model:Construction] OpenStudio Construction object
533
- #
532
+ # @param construction [OpenStudio:Model:Construction] OpenStudio Construction object
534
533
  # @return [Double] the U-Factor in W/m^2*K
535
534
  def construction_calculated_fenestration_u_factor_w_frame(construction)
536
535
  construction_name = construction.name.get.to_s
@@ -684,7 +683,7 @@ class Standard
684
683
  #
685
684
  # @param model [OpenStudio::Model::Model] OpenStudio model object
686
685
  # @param values [Hash] has of values
687
- # @param is_percentage [Bool] toggle is percentage
686
+ # @param is_percentage [Boolean] toggle is percentage
688
687
  # @return [Hash] json information
689
688
  def change_construction_properties_in_model(model, values, is_percentage = false)
690
689
  # puts JSON.pretty_generate(values)
@@ -746,8 +745,8 @@ class Standard
746
745
  # @param conductance [Double] conductance value in SI
747
746
  # @param shgc [Double] solar heat gain coefficient value, unitless
748
747
  # @param tvis [Double] visible transmittance
749
- # @param is_percentage [Bool] toggle is percentage
750
- # @return [Bool] returns true if successful, false if not
748
+ # @param is_percentage [Boolean] toggle is percentage
749
+ # @return [Boolean] returns true if successful, false if not
751
750
  def apply_changes_to_surface_construction(model, surface, conductance = nil, shgc = nil, tvis = nil, is_percentage = false)
752
751
  # If user has no changes...do nothing and return true.
753
752
  return true if conductance.nil? && shgc.nil? && tvis.nil?
@@ -877,7 +876,7 @@ class Standard
877
876
  #
878
877
  # @param construction [OpenStudio::Model::Construction] construction object
879
878
  # @param target_tvis [Double] Visible Transmittance
880
- # @return [Bool] returns true if successful, false if not
879
+ # @return [Boolean] returns true if successful, false if not
881
880
  def construction_set_glazing_tvis(construction, target_tvis)
882
881
  if target_tvis >= 1.0
883
882
  OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Construction', "Can only set the Tvis can only be set to less than 1.0. #{target_tvis} is greater than 1.0")
@@ -18,7 +18,7 @@ module CoolingTower
18
18
  #
19
19
  # @param cooling_tower [OpenStudio::Model::StraightComponent] cooling tower object, allowable types:
20
20
  # CoolingTowerSingleSpeed, CoolingTowerTwoSpeed, and CoolingTowerVariableSpeed
21
- # @return [Bool] returns true if successful, false if not
21
+ # @return [Boolean] returns true if successful, false if not
22
22
  def cooling_tower_apply_minimum_power_per_flow(cooling_tower)
23
23
  # Get the design water flow rate
24
24
  design_water_flow_m3_per_s = nil
@@ -51,11 +51,11 @@ module CoolingTower
51
51
  fan_type = nil
52
52
  if name.include?('Centrifugal')
53
53
  fan_type = 'Centrifugal'
54
- elsif name.include?('Propeller or Axial')
54
+ elsif name.include?('Propeller') || name.include?('Axial')
55
55
  fan_type = 'Propeller or Axial'
56
- end
57
- unless fan_type.nil?
58
- search_criteria['fan_type'] = fan_type
56
+ else
57
+ fan_type = 'Propeller or Axial'
58
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoolingTower', "#{cooling_tower.name} fan type is not discernible from the name. Defaulting to Propeller or Axial.")
59
59
  end
60
60
 
61
61
  # Limit on Centrifugal Fan
@@ -65,13 +65,13 @@ module CoolingTower
65
65
  if gpm_limit
66
66
  if design_water_flow_gpm >= gpm_limit
67
67
  fan_type = 'Propeller or Axial'
68
- search_criteria['fan_type'] = fan_type
69
68
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoolingTower', "For #{cooling_tower.name}, the design flow rate of #{design_water_flow_gpm.round} gpm is higher than the limit of #{gpm_limit.round} gpm for open centrifugal towers. This tower must meet the minimum performance of #{fan_type} instead.")
70
69
  end
71
70
  end
72
71
  end
73
72
 
74
73
  # Get the cooling tower properties
74
+ search_criteria['fan_type'] = fan_type
75
75
  ct_props = model_find_object(heat_rejection, search_criteria)
76
76
  unless ct_props
77
77
  OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoolingTower', "For #{cooling_tower.name}, cannot find heat rejection properties, cannot apply standard efficiencies or curves.")
@@ -6,7 +6,7 @@ class Standard
6
6
  # Applies the standard efficiency ratings and typical performance curves to this object.
7
7
  #
8
8
  # @param cooling_tower_single_speed [OpenStudio::Model::CoolingTowerSingleSpeed] single speed cooling tower
9
- # @return [Bool] returns true if successful, false if not
9
+ # @return [Boolean] returns true if successful, false if not
10
10
  def cooling_tower_single_speed_apply_efficiency_and_curves(cooling_tower_single_speed)
11
11
  cooling_tower_apply_minimum_power_per_flow(cooling_tower_single_speed)
12
12
  return true
@@ -6,7 +6,7 @@ class Standard
6
6
  # Applies the standard efficiency ratings and typical performance curves to this object.
7
7
  #
8
8
  # @param cooling_tower_two_speed [OpenStudio::Model::CoolingTowerTwoSpeed] two speed cooling tower
9
- # @return [Bool] returns true if successful, false if not
9
+ # @return [Boolean] returns true if successful, false if not
10
10
  def cooling_tower_two_speed_apply_efficiency_and_curves(cooling_tower_two_speed)
11
11
  cooling_tower_apply_minimum_power_per_flow(cooling_tower_two_speed)
12
12
 
@@ -6,7 +6,7 @@ class Standard
6
6
  # Applies the standard efficiency ratings and typical performance curves to this object.
7
7
  #
8
8
  # @param cooling_tower_variable_speed [OpenStudio::Model::CoolingTowerVariableSpeed] variable speed cooling tower
9
- # @return [Bool] returns true if successful, false if not
9
+ # @return [Boolean] returns true if successful, false if not
10
10
  def cooling_tower_variable_speed_apply_efficiency_and_curves(cooling_tower_variable_speed)
11
11
  cooling_tower_apply_minimum_power_per_flow(cooling_tower_variable_speed)
12
12
  return true
@@ -8,7 +8,7 @@ module Fan
8
8
  # @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
9
9
  # FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
10
10
  # @param allowed_bhp [Double] allowable brake horsepower
11
- # @return [Bool] returns true if successful, false if not
11
+ # @return [Boolean] returns true if successful, false if not
12
12
  def fan_apply_standard_minimum_motor_efficiency(fan, allowed_bhp)
13
13
  # Find the motor efficiency
14
14
  motor_eff, nominal_hp = fan_standard_minimum_motor_efficiency_and_size(fan, allowed_bhp)
@@ -39,7 +39,7 @@ module Fan
39
39
  # @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
40
40
  # FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
41
41
  # @param target_fan_power [Double] the target fan power in watts
42
- # @return [Bool] returns true if successful, false if not
42
+ # @return [Boolean] returns true if successful, false if not
43
43
  def fan_adjust_pressure_rise_to_meet_fan_power(fan, target_fan_power)
44
44
  # Get design supply air flow rate (whether autosized or hard-sized)
45
45
  dsn_air_flow_m3_per_s = 0
@@ -161,7 +161,7 @@ module Fan
161
161
  # @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
162
162
  # FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
163
163
  # @param motor_eff [Double] motor efficiency (0.0 to 1.0)
164
- # @return [Bool] returns true if successful, false if not
164
+ # @return [Boolean] returns true if successful, false if not
165
165
  def fan_change_motor_efficiency(fan, motor_eff)
166
166
  # Calculate the existing impeller efficiency
167
167
  existing_motor_eff = 0.7
@@ -190,7 +190,7 @@ module Fan
190
190
  # @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
191
191
  # FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
192
192
  # @param impeller_eff [Double] impeller efficiency (0.0 to 1.0)
193
- # @return [Bool] returns true if successful, false if not
193
+ # @return [Boolean] returns true if successful, false if not
194
194
  def fan_change_impeller_efficiency(fan, impeller_eff)
195
195
  # Get the existing motor efficiency
196
196
  existing_motor_eff = 0.7
@@ -305,7 +305,7 @@ module Fan
305
305
  #
306
306
  # @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
307
307
  # FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
308
- # @return [Bool] returns true if it is a small fan, false if not
308
+ # @return [Boolean] returns true if it is a small fan, false if not
309
309
  def fan_small_fan?(fan)
310
310
  is_small = false
311
311
 
@@ -348,13 +348,7 @@ module Fan
348
348
  # @return [Double] rated power consumption per flow in watters per cfm, W*min/ft^3
349
349
  def fan_rated_w_per_cfm(fan)
350
350
  # Get design power (whether autosized or hard-sized)
351
- rated_power_w = fan.model.getAutosizedValueFromEquipmentSummary(fan, 'Fans', 'Rated Electric Power', 'W')
352
- if rated_power_w.is_initialized
353
- rated_power_w = rated_power_w.get
354
- else
355
- rated_power_w = fan_fanpower(fan)
356
- OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Fan', "For #{fan.name}, could not find rated fan power from Equipment Summary. Will calculate it based on current pressure rise and total fan efficiency")
357
- end
351
+ rated_power_w = fan_fanpower(fan)
358
352
 
359
353
  if fan.maximumFlowRate.is_initialized
360
354
  max_m3_per_s = fan.ratedFlowRate.get
@@ -17,7 +17,7 @@ class Standard
17
17
  # Multi Zone VAV with VSD and Fixed SP Setpoint,
18
18
  # Multi Zone VAV with VSD and Static Pressure Reset,
19
19
  # Single Zone VAV Fan
20
- # @return [Bool] returns true if successful, false if not
20
+ # @return [Boolean] returns true if successful, false if not
21
21
  def fan_variable_volume_set_control_type(fan_variable_volume, control_type)
22
22
  # Determine the coefficients
23
23
  coeff_a = nil
@@ -113,7 +113,7 @@ class Standard
113
113
  # Determines whether there is a requirement to have a VSD or some other method to reduce fan power at low part load ratios.
114
114
  #
115
115
  # @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
116
- # @return [Bool] returns true if required, false if not
116
+ # @return [Boolean] returns true if required, false if not
117
117
  def fan_variable_volume_part_load_fan_power_limitation?(fan_variable_volume)
118
118
  part_load_control_required = false
119
119
 
@@ -21,7 +21,7 @@ class Standard
21
21
  # @param equipment_type [String] heat rejection equipment type enumeration used for lookup query,
22
22
  # options are 'Closed Cooling Tower', modeled as an EvaporativeFluidCooler,
23
23
  # or 'Dry Cooler', modeled as a FluidCooler
24
- # @return [Bool] returns true if successful, false if not
24
+ # @return [Boolean] returns true if successful, false if not
25
25
  def fluid_cooler_apply_minimum_power_per_flow(fluid_cooler, equipment_type: 'Closed Cooling Tower')
26
26
  # Get the design water flow rate
27
27
  if fluid_cooler.designWaterFlowRate.is_initialized
@@ -7,7 +7,7 @@ class Standard
7
7
  #
8
8
  # @param headered_pumps_variable_speed [OpenStudio::Model::HeaderedPumpsVariableSpeed] headered variable speed pumps object
9
9
  # @param control_type [String] valid choices are Riding Curve, VSD No Reset, VSD DP Reset
10
- # @return [Bool] returns true if successful, false if not
10
+ # @return [Boolean] returns true if successful, false if not
11
11
  def headered_pumps_variable_speed_set_control_type(headered_pumps_variable_speed, control_type)
12
12
  # Determine the coefficients
13
13
  coeff_a = nil
@@ -4,7 +4,7 @@ class Standard
4
4
  # Sets the minimum effectiveness of the heat exchanger per the standard.
5
5
  #
6
6
  # @param heat_exchanger_air_to_air_sensible_and_latent [OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent] the heat exchanger
7
- # @return [Bool] returns true if successful, false if not
7
+ # @return [Boolean] returns true if successful, false if not
8
8
  def heat_exchanger_air_to_air_sensible_and_latent_apply_effectiveness(heat_exchanger_air_to_air_sensible_and_latent)
9
9
  # Assumed to be sensible and latent at all flow
10
10
  full_htg_sens_eff, full_htg_lat_eff, part_htg_sens_eff, part_htg_lat_eff, full_cool_sens_eff, full_cool_lat_eff, part_cool_sens_eff, part_cool_lat_eff = heat_exchanger_air_to_air_sensible_and_latent_minimum_effectiveness(heat_exchanger_air_to_air_sensible_and_latent)
@@ -46,9 +46,9 @@ class Standard
46
46
  # climate zones a 50% ERR at typical condition leads a ERR > 50%,
47
47
  # the ERR is thus scaled down.
48
48
  #
49
- # @param enthalpy_recovery_ratio [float] Enthalpy Recovery Ratio (ERR)
49
+ # @param enthalpy_recovery_ratio [Double] Enthalpy Recovery Ratio (ERR)
50
50
  # @param climate_zone [String] climate zone
51
- # @return [float] adjusted ERR
51
+ # @return [Double] adjusted ERR
52
52
  def enthalpy_recovery_ratio_design_to_typical_adjustment(enthalpy_recovery_ratio, climate_zone)
53
53
  if climate_zone.include? '2B'
54
54
  enthalpy_recovery_ratio /= 0.65 / 0.55