openstudio-standards 0.4.0 → 0.5.0
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/LICENSE.md +33 -0
- data/data/inventory/thermal_bridging.csv +90 -0
- data/data/standards/OpenStudio_Standards-deer-comstock.xlsx +0 -0
- data/data/standards/manage_OpenStudio_Standards.rb +1 -1
- data/data/standards/test_performance_expected_dd_results.csv +2014 -1891
- data/lib/openstudio-standards/btap/analysis.rb +8 -8
- data/lib/openstudio-standards/btap/bridging.rb +664 -645
- data/lib/openstudio-standards/btap/btap.model.rb +14 -14
- data/lib/openstudio-standards/btap/btap.rb +7 -7
- data/lib/openstudio-standards/btap/btap_result.rb +1 -1
- data/lib/openstudio-standards/btap/economics.rb +23 -23
- data/lib/openstudio-standards/btap/envelope.rb +8 -8
- data/lib/openstudio-standards/btap/equest.rb +1 -1
- data/lib/openstudio-standards/btap/geometry.rb +2 -2
- data/lib/openstudio-standards/btap/mpc.rb +7 -7
- data/lib/openstudio-standards/btap/schedules.rb +1 -1
- data/lib/openstudio-standards/btap/simmanager.rb +4 -4
- data/lib/openstudio-standards/btap/spaceloads.rb +26 -26
- data/lib/openstudio-standards/btap/utilities.rb +6 -6
- data/lib/openstudio-standards/btap/vintagizer.rb +1 -1
- data/lib/openstudio-standards/constructions/information.rb +83 -0
- data/lib/openstudio-standards/constructions/materials/modify.rb +72 -0
- data/lib/openstudio-standards/constructions/modify.rb +80 -0
- data/lib/openstudio-standards/create_typical/create_typical.rb +983 -0
- data/lib/openstudio-standards/create_typical/enumerations.rb +484 -0
- data/lib/openstudio-standards/create_typical/space_type_blend.rb +791 -0
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +494 -0
- data/lib/openstudio-standards/daylighting/space.rb +47 -0
- data/lib/openstudio-standards/geometry/create.rb +801 -0
- data/lib/openstudio-standards/geometry/create_bar.rb +2170 -0
- data/lib/openstudio-standards/geometry/information.rb +462 -0
- data/lib/openstudio-standards/geometry/modify.rb +48 -0
- data/lib/openstudio-standards/hvac/air_loop/information.rb +79 -0
- data/lib/openstudio-standards/hvac/cbecs_hvac.rb +616 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +91 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +2 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +3 -3
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +14 -14
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +16 -16
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +13 -13
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +18 -18
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +957 -957
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +84 -16
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +61 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +43 -30
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +774 -117
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +340 -481
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +22 -22
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/qaqc/calibration.rb +131 -0
- data/lib/openstudio-standards/qaqc/create_results.rb +983 -0
- data/lib/openstudio-standards/qaqc/envelope.rb +399 -0
- data/lib/openstudio-standards/qaqc/eui.rb +213 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +1943 -0
- data/lib/openstudio-standards/qaqc/internal_loads.rb +568 -0
- data/lib/openstudio-standards/qaqc/reporting.rb +141 -0
- data/lib/openstudio-standards/qaqc/schedules.rb +129 -0
- data/lib/openstudio-standards/qaqc/service_water_heating.rb +273 -0
- data/lib/openstudio-standards/qaqc/weather_files.rb +497 -0
- data/lib/openstudio-standards/qaqc/zone_conditions.rb +278 -0
- data/lib/openstudio-standards/schedules/create.rb +364 -0
- data/lib/openstudio-standards/schedules/information.rb +169 -0
- data/lib/openstudio-standards/schedules/modify.rb +445 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +110 -71
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +16 -10
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Construction.rb +17 -18
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +6 -6
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +6 -12
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.Model.rb +411 -261
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -29
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +14 -14
- data/lib/openstudio-standards/standards/Standards.Space.rb +37 -30
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +38 -29
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.Surface.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +109 -66
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +11 -4
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +5 -21
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +36 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +53 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +211 -211
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +22 -28
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater.rb +1 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +7 -59
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -21
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb +101 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +643 -526
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface.rb +8 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +17 -77
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +74 -16
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +96 -44
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Surface.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone.rb +18 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +328 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +0 -118
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_rejection.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md +35 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_plug_load_measures.md +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +228 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +131 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_space.csv +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +109 -27
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +18 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json +260 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.economizers.json +246 -4
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +5 -2
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json +25 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chillers.json +44 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +225 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +2 -2
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +193 -73
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +10 -4
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +4 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json +32 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +36 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm +47587 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm +49764 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Warehouse.osm +283 -297
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_type_unit_definitions.txt +2 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/NECB2011/data/standards_data.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +49 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +400 -202
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +18 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +615 -307
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +10 -5
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +1 -1
- data/lib/openstudio-standards/utilities/assertion.rb +128 -0
- data/lib/openstudio-standards/utilities/logging.rb +2 -3
- data/lib/openstudio-standards/utilities/object_info.rb +39 -18
- data/lib/openstudio-standards/utilities/schedule_translator.rb +8 -6
- data/lib/openstudio-standards/utilities/simulation.rb +24 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +10 -5
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +8 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +3 -3
- data/lib/openstudio-standards/weather/information.rb +35 -0
- data/lib/openstudio-standards.rb +69 -5
- metadata +54 -18
- data/License.txt +0 -65
- data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +0 -59
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb +0 -13
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +0 -36
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +0 -898
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +0 -126
- data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +0 -356
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +0 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb +0 -110
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb +0 -5
@@ -63,7 +63,7 @@
|
|
63
63
|
#
|
64
64
|
# #This method will scale people loads.
|
65
65
|
# #@author phylroy.lopez@nrcan.gc.ca
|
66
|
-
# #@param model [OpenStudio::
|
66
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
67
67
|
# #@param factor [Float]
|
68
68
|
# def self.scale_people_loads( model, factor )
|
69
69
|
# model.getPeoples.sort.each do |item|
|
@@ -73,7 +73,7 @@
|
|
73
73
|
#
|
74
74
|
# #This method will scale people loads schedule.
|
75
75
|
# #@author phylroy.lopez@nrcan.gc.ca
|
76
|
-
# #@param model [OpenStudio::
|
76
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
77
77
|
# #@param a_coef [Float]
|
78
78
|
# #@param b_coef [Float]
|
79
79
|
# #@param c_coef [Float]
|
@@ -88,7 +88,7 @@
|
|
88
88
|
#
|
89
89
|
# #This method will scale lighting loads.
|
90
90
|
# #@author phylroy.lopez@nrcan.gc.ca
|
91
|
-
# #@param model [OpenStudio::
|
91
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
92
92
|
# #@param factor [Float]
|
93
93
|
# def self.scale_lighting_loads( model, factor )
|
94
94
|
# model.getLightss.sort.each do |item|
|
@@ -98,7 +98,7 @@
|
|
98
98
|
#
|
99
99
|
# #This method will scale lighting loads schedule.
|
100
100
|
# #@author phylroy.lopez@nrcan.gc.ca
|
101
|
-
# #@param model [OpenStudio::
|
101
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
102
102
|
# #@param a_coef [Float]
|
103
103
|
# #@param b_coef [Float]
|
104
104
|
# #@param c_coef [Float]
|
@@ -113,7 +113,7 @@
|
|
113
113
|
#
|
114
114
|
# #This method will scale electrical loads.
|
115
115
|
# #@author phylroy.lopez@nrcan.gc.ca
|
116
|
-
# #@param model [OpenStudio::
|
116
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
117
117
|
# #@param factor [Float]
|
118
118
|
# def self.scale_electrical_loads( model, factor )
|
119
119
|
# model.getElectricEquipments.sort.each do |item|
|
@@ -123,7 +123,7 @@
|
|
123
123
|
#
|
124
124
|
# #This method will scale electrical loads schedule.
|
125
125
|
# #@author phylroy.lopez@nrcan.gc.ca
|
126
|
-
# #@param model [OpenStudio::
|
126
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
127
127
|
# #@param a_coef [Float]
|
128
128
|
# #@param b_coef [Float]
|
129
129
|
# #@param c_coef [Float]
|
@@ -137,7 +137,7 @@
|
|
137
137
|
#
|
138
138
|
# #This method will scale hotwater loads.
|
139
139
|
# #@author phylroy.lopez@nrcan.gc.ca
|
140
|
-
# #@param model [OpenStudio::
|
140
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
141
141
|
# #@param factor [Float]
|
142
142
|
# def self.scale_hot_water_loads( model, factor )
|
143
143
|
# model.getHotWaterEquipments.sort.each do |item|
|
@@ -147,7 +147,7 @@
|
|
147
147
|
#
|
148
148
|
# #This method will scale Outdoor Air loads.
|
149
149
|
# #@author phylroy.lopez@nrcan.gc.ca
|
150
|
-
# #@param model [OpenStudio::
|
150
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
151
151
|
# #@param factor [Float]
|
152
152
|
# def self.scale_oa_loads( model, factor )
|
153
153
|
# model.getDesignSpecificationOutdoorAirs.sort.each do |oa_def|
|
@@ -160,7 +160,7 @@
|
|
160
160
|
#
|
161
161
|
# #This method will scale infiltration loads.
|
162
162
|
# #@author phylroy.lopez@nrcan.gc.ca
|
163
|
-
# #@param model [OpenStudio::
|
163
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
164
164
|
# #@param factor [Float]
|
165
165
|
# def self.scale_inflitration_loads( model, factor )
|
166
166
|
# model.getSpaceInfiltrationDesignFlowRates.sort.each do |infiltration_load|
|
@@ -173,7 +173,7 @@
|
|
173
173
|
#
|
174
174
|
# #This method will set the infiltration magnitude.
|
175
175
|
# #@author phylroy.lopez@nrcan.gc.ca
|
176
|
-
# #@param model [OpenStudio::
|
176
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
177
177
|
# #@param setDesignFlowRate [Float]
|
178
178
|
# #@param setFlowperSpaceFloorArea [Float]
|
179
179
|
# #@param setFlowperExteriorSurfaceArea [Float]
|
@@ -202,7 +202,7 @@
|
|
202
202
|
#
|
203
203
|
# #This method removes people loads from the model.
|
204
204
|
# #@author phylroy.lopez@nrcan.gc.ca
|
205
|
-
# #@param model [OpenStudio::
|
205
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
206
206
|
# def self.remove_all_people_loads(model)
|
207
207
|
# model.getPeoples.sort.each {|people| people.remove}
|
208
208
|
# model.getPeopleDefinitions.sort.each {|people| people.remove}
|
@@ -211,7 +211,7 @@
|
|
211
211
|
#
|
212
212
|
# #This method created people loads from the model.
|
213
213
|
# #@author phylroy.lopez@nrcan.gc.ca
|
214
|
-
# #@param model [OpenStudio::
|
214
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
215
215
|
# #@param people_name [String]
|
216
216
|
# #@param floor_area_per_person [Float]
|
217
217
|
# #@param multiplier [Float]
|
@@ -239,7 +239,7 @@
|
|
239
239
|
#
|
240
240
|
# #This method removes light loads from model.
|
241
241
|
# #@author phylroy.lopez@nrcan.gc.ca
|
242
|
-
# #@param model [OpenStudio::
|
242
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
243
243
|
# def self.remove_all_light_loads(model)
|
244
244
|
# model.getLightss.sort.each {|item| item.remove}
|
245
245
|
# model.getLightsDefinitions.sort.each {|item| item.remove}
|
@@ -247,7 +247,7 @@
|
|
247
247
|
#
|
248
248
|
# #This method created people loads from the model.
|
249
249
|
# #@author phylroy.lopez@nrcan.gc.ca
|
250
|
-
# #@param model [OpenStudio::
|
250
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
251
251
|
# #@param light_name [String]
|
252
252
|
# #@param light_watts_per_floor_area [Float]
|
253
253
|
# #@param multiplier [Float]
|
@@ -268,7 +268,7 @@
|
|
268
268
|
#
|
269
269
|
# #This method removes elec loads from model.
|
270
270
|
# #@author phylroy.lopez@nrcan.gc.ca
|
271
|
-
# #@param model [OpenStudio::
|
271
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
272
272
|
# def self.remove_all_electric_loads(model)
|
273
273
|
# model.getElectricEquipments.sort.each {|item| item.remove}
|
274
274
|
# model.getElectricEquipmentDefinitions.sort.each {|item| item.remove}
|
@@ -277,7 +277,7 @@
|
|
277
277
|
#
|
278
278
|
# #This method created people loads from the model.
|
279
279
|
# #@author phylroy.lopez@nrcan.gc.ca
|
280
|
-
# #@param model [OpenStudio::
|
280
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
281
281
|
# #@param elec_name [String]
|
282
282
|
# #@param elec_watts_per_floor_area [Float]
|
283
283
|
# #@param multiplier [Float]
|
@@ -297,7 +297,7 @@
|
|
297
297
|
#
|
298
298
|
# #This method removes hot water loads from model.
|
299
299
|
# #@author phylroy.lopez@nrcan.gc.ca
|
300
|
-
# #@param model [OpenStudio::
|
300
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
301
301
|
# def self.remove_all_hot_water_loads(model)
|
302
302
|
# model.getHotWaterEquipments.sort.each {|item| item.remove}
|
303
303
|
# model.getHotWaterEquipmentDefinitions.sort.each {|item| item.remove}
|
@@ -305,7 +305,7 @@
|
|
305
305
|
#
|
306
306
|
# #This method creats hot water load.
|
307
307
|
# #@author phylroy.lopez@nrcan.gc.ca
|
308
|
-
# #@param model [OpenStudio::
|
308
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
309
309
|
# #@param hot_water_name [String]
|
310
310
|
# #@param hot_water_watts_per_floor_area [Float]
|
311
311
|
# #@param multiplier [Float]
|
@@ -326,7 +326,7 @@
|
|
326
326
|
#
|
327
327
|
# #This method removes all design specification OA from model.
|
328
328
|
# #@author phylroy.lopez@nrcan.gc.ca
|
329
|
-
# #@param model [OpenStudio::
|
329
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
330
330
|
# def self.remove_all_DesignSpecificationOutdoorAir(model)
|
331
331
|
# model.getDesignSpecificationOutdoorAirs.sort.each { |item| item.remove }
|
332
332
|
# end
|
@@ -334,7 +334,7 @@
|
|
334
334
|
#
|
335
335
|
# #This method removes all space infiltration design flow rate OA from model.
|
336
336
|
# #@author phylroy.lopez@nrcan.gc.ca
|
337
|
-
# #@param model [OpenStudio::
|
337
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
338
338
|
# def self.remove_all_SpaceInfiltrationDesignFlowRate(model)
|
339
339
|
# OpenStudio::Model::SpaceInfiltrationDesignFlowRate
|
340
340
|
# model.getSpaceInfiltrationDesignFlowRates.sort.each { |item| item.remove }
|
@@ -342,7 +342,7 @@
|
|
342
342
|
#
|
343
343
|
# #This method creats hot water load.
|
344
344
|
# #@author phylroy.lopez@nrcan.gc.ca
|
345
|
-
# #@param model [OpenStudio::
|
345
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
346
346
|
# #@param oa_name [String]
|
347
347
|
# #@param oa_person [Fixnum]
|
348
348
|
# #@param oa_area [Fixnum]
|
@@ -350,7 +350,7 @@
|
|
350
350
|
# #@param oa_flowrate [Fixnum]
|
351
351
|
# #@param method [String]
|
352
352
|
# #@param schedule [Float]
|
353
|
-
# #@return [OpenStudio::
|
353
|
+
# #@return [OpenStudio::Model::Model] oa_def
|
354
354
|
# def self.create_oa_load(model,oa_name,oa_person = 0 ,oa_area = 0, oa_ach = 0, oa_flowrate = 0, method = "Maximum",schedule = nil)
|
355
355
|
# raise("DesignSpecificationOutdoorAir #{name} already exists. Please use a different name") unless model.getDesignSpecificationOutdoorAirByName( oa_name ).empty?
|
356
356
|
# #units are in m3/s for flow and m2 for area.
|
@@ -373,7 +373,7 @@
|
|
373
373
|
#
|
374
374
|
# #This method removes infiltration from model..
|
375
375
|
# #@author phylroy.lopez@nrcan.gc.ca
|
376
|
-
# #@param model [OpenStudio::
|
376
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
377
377
|
# def self.remove_all_SpaceInfiltrationDesignFlowRates(model)
|
378
378
|
# model.getSpaceInfiltrationDesignFlowRates.sort.each { |item| item.remove }
|
379
379
|
# end
|
@@ -381,7 +381,7 @@
|
|
381
381
|
# #This method creates infiltration load.
|
382
382
|
# #NECB infiltration rate is 0.25L/s/m2 or 0.00025 m3/s/m2
|
383
383
|
# #@author phylroy.lopez@nrcan.gc.ca
|
384
|
-
# #@param model [OpenStudio::
|
384
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
385
385
|
# #@return [String] infiltration_load
|
386
386
|
# def self.create_infiltration_load(model,
|
387
387
|
# infil_name,
|
@@ -419,7 +419,7 @@
|
|
419
419
|
#
|
420
420
|
# #This method removes all loads from model.
|
421
421
|
# #@author phylroy.lopez@nrcan.gc.ca
|
422
|
-
# #@param model [OpenStudio::
|
422
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
423
423
|
# def self.remove_all_casual_loads(model)
|
424
424
|
# self.remove_all_people_loads(model)
|
425
425
|
# self.remove_all_light_loads(model)
|
@@ -429,7 +429,7 @@
|
|
429
429
|
#
|
430
430
|
# #This method removes all space loads from model.
|
431
431
|
# #@author phylroy.lopez@nrcan.gc.ca
|
432
|
-
# #@param model [OpenStudio::
|
432
|
+
# #@param model [OpenStudio::Model::Model] A model object
|
433
433
|
# def self.remove_all_SpaceLoads(model)
|
434
434
|
# model.getSpaceLoads.sort.each { |item| item.remove }
|
435
435
|
# model.getSpaceLoadDefinitions.sort.each { |item| item.remove }
|
@@ -49,9 +49,9 @@
|
|
49
49
|
# #argument model(s). This is handy for quickly viewing changes to the file during
|
50
50
|
# #runtime for debugging and QA.
|
51
51
|
# #@author phylroy.lopez@nrcan.gc.ca
|
52
|
-
# #@param model1 [OpenStudio::
|
53
|
-
# #@param model2 [OpenStudio::
|
54
|
-
# #@param model3 [OpenStudio::
|
52
|
+
# #@param model1 [OpenStudio::Model::Model] A model object.
|
53
|
+
# #@param model2 [OpenStudio::Model::Model] A model object.
|
54
|
+
# #@param model3 [OpenStudio::Model::Model] A model object.
|
55
55
|
# def self.kdiff3_model_osm(model1, model2, model3 = "")
|
56
56
|
# Dir::mkdir("C:\\kdiff_test") unless File.exists?("C:\\kdiff_test")
|
57
57
|
# model1.save(OpenStudio::Path.new("c:\\kdiff_test\\diffA.osm"))
|
@@ -71,9 +71,9 @@
|
|
71
71
|
# #argument model(s). This is handy for quickly viewing changes to the file during
|
72
72
|
# #runtime for debugging and QA.
|
73
73
|
# #@author phylroy.lopez@nrcan.gc.ca
|
74
|
-
# #@param model1 [OpenStudio::
|
75
|
-
# #@param model2 [OpenStudio::
|
76
|
-
# #@param model3 [OpenStudio::
|
74
|
+
# #@param model1 [OpenStudio::Model::Model] A model object.
|
75
|
+
# #@param model2 [OpenStudio::Model::Model] A model object.
|
76
|
+
# #@param model3 [OpenStudio::Model::Model] A model object.
|
77
77
|
# def self.kdiff3_model_idf(model1, model2, model3 = "")
|
78
78
|
# Dir::mkdir("C:\\kdiff_test") unless File.exists?("C:\\kdiff_test")
|
79
79
|
#
|
@@ -24,7 +24,7 @@ class Vintagizer
|
|
24
24
|
|
25
25
|
#This method loads Vintage database information.
|
26
26
|
#@author phylroy.lopez@nrcan.gc.ca
|
27
|
-
#@param model [OpenStudio::
|
27
|
+
#@param model [OpenStudio::Model::Model] A model object
|
28
28
|
#@param file [String]
|
29
29
|
#@param selectionHash [???]
|
30
30
|
def initialize(model,file,selectionHash)
|
@@ -0,0 +1,83 @@
|
|
1
|
+
# Methods to create typical models
|
2
|
+
module OpenstudioStandards
|
3
|
+
module Constructions
|
4
|
+
# @!group Information
|
5
|
+
|
6
|
+
# Returns the solar reflectance index of an exposed surface.
|
7
|
+
# On a scale of 0 to 100, standard black is 0, and standard white is 100.
|
8
|
+
# The calculation derived from ASTM E1980 assuming medium wind speed.
|
9
|
+
#
|
10
|
+
# @param construction [OpenStudio::Model::Construction] OpenStudio Construction object
|
11
|
+
# @return [Double] The solar reflectance value
|
12
|
+
def self.construction_get_solar_reflectance_index(construction)
|
13
|
+
exposed_material = construction.to_LayeredConstruction.get.getLayer(0)
|
14
|
+
solar_absorptance = exposed_material.to_OpaqueMaterial.get.solarAbsorptance
|
15
|
+
thermal_emissivity = exposed_material.to_OpaqueMaterial.get.thermalAbsorptance
|
16
|
+
x = (20.797 * solar_absorptance - 0.603 * thermal_emissivity) / (9.5205 * thermal_emissivity + 12.0)
|
17
|
+
sri = 123.97 - 141.35 * x + 9.6555 * x * x
|
18
|
+
|
19
|
+
return sri
|
20
|
+
end
|
21
|
+
|
22
|
+
# report names of constructions in a construction set
|
23
|
+
#
|
24
|
+
# @param default_construction_set [OpenStudio::Model::Defaultdefault_construction_set] OpenStudio Defaultdefault_construction_set object
|
25
|
+
# @return [Array<OpenStudio::Model::Construction>] Array of OpenStudio Construction objects
|
26
|
+
def self.construction_set_get_constructions(default_construction_set)
|
27
|
+
construction_array = []
|
28
|
+
|
29
|
+
# populate exterior surfaces
|
30
|
+
if default_construction_set.defaultExteriorSurfaceConstructions.is_initialized
|
31
|
+
default_surface_constructions = default_construction_set.defaultExteriorSurfaceConstructions.get
|
32
|
+
construction_array << default_surface_constructions.floorConstruction.get if default_surface_constructions.floorConstruction.is_initialized
|
33
|
+
construction_array << default_surface_constructions.wallConstruction.get if default_surface_constructions.wallConstruction.is_initialized
|
34
|
+
construction_array << default_surface_constructions.roofCeilingConstruction.get if default_surface_constructions.roofCeilingConstruction.is_initialized
|
35
|
+
end
|
36
|
+
# populate interior surfaces
|
37
|
+
if default_construction_set.defaultInteriorSurfaceConstructions.is_initialized
|
38
|
+
default_surface_constructions = default_construction_set.defaultInteriorSurfaceConstructions.get
|
39
|
+
construction_array << default_surface_constructions.floorConstruction.get if default_surface_constructions.floorConstruction.is_initialized
|
40
|
+
construction_array << default_surface_constructions.wallConstruction.get if default_surface_constructions.wallConstruction.is_initialized
|
41
|
+
construction_array << default_surface_constructions.roofCeilingConstruction.get if default_surface_constructions.roofCeilingConstruction.is_initialized
|
42
|
+
end
|
43
|
+
# populate ground surfaces
|
44
|
+
if default_construction_set.defaultGroundContactSurfaceConstructions.is_initialized
|
45
|
+
default_surface_constructions = default_construction_set.defaultGroundContactSurfaceConstructions.get
|
46
|
+
construction_array << default_surface_constructions.floorConstruction.get if default_surface_constructions.floorConstruction.is_initialized
|
47
|
+
construction_array << default_surface_constructions.wallConstruction.get if default_surface_constructions.wallConstruction.is_initialized
|
48
|
+
construction_array << default_surface_constructions.roofCeilingConstruction.get if default_surface_constructions.roofCeilingConstruction.is_initialized
|
49
|
+
end
|
50
|
+
# populate exterior sub-surfaces
|
51
|
+
if default_construction_set.defaultExteriorSubSurfaceConstructions.is_initialized
|
52
|
+
default_subsurface_constructions = default_construction_set.defaultExteriorSubSurfaceConstructions.get
|
53
|
+
construction_array << default_subsurface_constructions.fixedWindowConstruction.get if default_subsurface_constructions.fixedWindowConstruction.is_initialized
|
54
|
+
construction_array << default_subsurface_constructions.operableWindowConstruction.get if default_subsurface_constructions.operableWindowConstruction.is_initialized
|
55
|
+
construction_array << default_subsurface_constructions.doorConstruction.get if default_subsurface_constructions.doorConstruction.is_initialized
|
56
|
+
construction_array << default_subsurface_constructions.glassDoorConstruction.get if default_subsurface_constructions.glassDoorConstruction.is_initialized
|
57
|
+
construction_array << default_subsurface_constructions.overheadDoorConstruction.get if default_subsurface_constructions.overheadDoorConstruction.is_initialized
|
58
|
+
construction_array << default_subsurface_constructions.skylightConstruction.get if default_subsurface_constructions.skylightConstruction.is_initialized
|
59
|
+
construction_array << default_subsurface_constructions.tubularDaylightDomeConstruction.get if default_subsurface_constructions.tubularDaylightDomeConstruction.is_initialized
|
60
|
+
construction_array << default_subsurface_constructions.tubularDaylightDiffuserConstruction.get if default_subsurface_constructions.tubularDaylightDiffuserConstruction.is_initialized
|
61
|
+
end
|
62
|
+
# populate interior sub-surfaces
|
63
|
+
if default_construction_set.defaultInteriorSubSurfaceConstructions.is_initialized
|
64
|
+
default_subsurface_constructions = default_construction_set.defaultInteriorSubSurfaceConstructions.get
|
65
|
+
construction_array << default_subsurface_constructions.fixedWindowConstruction.get if default_subsurface_constructions.fixedWindowConstruction.is_initialized
|
66
|
+
construction_array << default_subsurface_constructions.operableWindowConstruction.get if default_subsurface_constructions.operableWindowConstruction.is_initialized
|
67
|
+
construction_array << default_subsurface_constructions.doorConstruction.get if default_subsurface_constructions.doorConstruction.is_initialized
|
68
|
+
construction_array << default_subsurface_constructions.glassDoorConstruction.get if default_subsurface_constructions.glassDoorConstruction.is_initialized
|
69
|
+
construction_array << default_subsurface_constructions.overheadDoorConstruction.get if default_subsurface_constructions.overheadDoorConstruction.is_initialized
|
70
|
+
construction_array << default_subsurface_constructions.skylightConstruction.get if default_subsurface_constructions.skylightConstruction.is_initialized
|
71
|
+
construction_array << default_subsurface_constructions.tubularDaylightDomeConstruction.get if default_subsurface_constructions.tubularDaylightDomeConstruction.is_initialized
|
72
|
+
construction_array << default_subsurface_constructions.tubularDaylightDiffuserConstruction.get if default_subsurface_constructions.tubularDaylightDiffuserConstruction.is_initialized
|
73
|
+
end
|
74
|
+
# populate misc surfaces
|
75
|
+
construction_array << default_construction_set.interiorPartitionConstruction.get if default_construction_set.interiorPartitionConstruction.is_initialized
|
76
|
+
construction_array << default_construction_set.spaceShadingConstruction.get if default_construction_set.spaceShadingConstruction.is_initialized
|
77
|
+
construction_array << default_construction_set.buildingShadingConstruction.get if default_construction_set.buildingShadingConstruction.is_initialized
|
78
|
+
construction_array << default_construction_set.siteShadingConstruction.get if default_construction_set.siteShadingConstruction.is_initialized
|
79
|
+
|
80
|
+
return construction_array
|
81
|
+
end
|
82
|
+
end
|
83
|
+
end
|
@@ -0,0 +1,72 @@
|
|
1
|
+
# Methods to modify material properties
|
2
|
+
module OpenstudioStandards
|
3
|
+
module Constructions
|
4
|
+
module Materials
|
5
|
+
# @!group Modify
|
6
|
+
|
7
|
+
# change thermal resistance of opaque materials by increasing material thickness,
|
8
|
+
# or setting thermal resistance directly for massless or airgap materials.
|
9
|
+
#
|
10
|
+
# @param opaque_material [OpenStudio::Model::OpaqueMaterial] OpenStudio OpaqueMaterial object
|
11
|
+
# @param thermal_resistance [Double] Target thermal resistance of the material in m^2*K/W
|
12
|
+
# @return [OpenStudio::Model::OpaqueMaterial] OpenStudio OpaqueMaterial object
|
13
|
+
def self.opaque_material_set_thermal_resistance(opaque_material, thermal_resistance)
|
14
|
+
unless opaque_material.to_OpaqueMaterial.is_initialized
|
15
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.constructions.materials', "Object #{opaque_material} cannot be cast as an OpaqueMaterial object.")
|
16
|
+
return false
|
17
|
+
end
|
18
|
+
|
19
|
+
# edit insulation material
|
20
|
+
material = opaque_material.to_OpaqueMaterial.get
|
21
|
+
if material.to_MasslessOpaqueMaterial.is_initialized
|
22
|
+
material = material.to_MasslessOpaqueMaterial.get
|
23
|
+
material.setThermalResistance(thermal_resistance)
|
24
|
+
elsif material.to_AirGap.is_initialized
|
25
|
+
material = material.to_AirGap.get
|
26
|
+
material.setThermalResistance(thermal_resistance)
|
27
|
+
else
|
28
|
+
starting_thickness = material.thickness
|
29
|
+
target_thickness = starting_thickness * thermal_resistance / material.thermalResistance
|
30
|
+
material.setThickness(target_thickness)
|
31
|
+
end
|
32
|
+
|
33
|
+
return material.to_OpaqueMaterial.get
|
34
|
+
end
|
35
|
+
|
36
|
+
# set material surface properties
|
37
|
+
#
|
38
|
+
# @param opaque_material [OpenStudio::Model::OpaqueMaterial] OpenStudio OpaqueMaterial object
|
39
|
+
# @param roughness [String] surface roughness. Options are 'VeryRough', 'Rough', 'MediumRough',
|
40
|
+
# 'MediumSmooth', 'Smooth', and 'VerySmooth'
|
41
|
+
# @param thermal_absorptance [Double] target thermal absorptance
|
42
|
+
# @param solar_absorptance [Double] target solar absorptance
|
43
|
+
# @param visible_absorptance [Double] target visible absorptance
|
44
|
+
# @return [OpenStudio::Model::OpaqueMaterial] OpenStudio OpaqueMaterial object
|
45
|
+
def self.opaque_material_set_surface_properties(opaque_material,
|
46
|
+
roughness: nil,
|
47
|
+
thermal_absorptance: nil,
|
48
|
+
solar_absorptance: nil,
|
49
|
+
visible_absorptance: nil)
|
50
|
+
unless opaque_material.to_OpaqueMaterial.is_initialized
|
51
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.constructions.materials', "Object #{opaque_material} cannot be cast as an OpaqueMaterial object.")
|
52
|
+
return false
|
53
|
+
end
|
54
|
+
|
55
|
+
# set requested material properties
|
56
|
+
material = opaque_material.to_OpaqueMaterial.get
|
57
|
+
if material.to_StandardOpaqueMaterial.is_initialized
|
58
|
+
material = material.to_StandardOpaqueMaterial.get
|
59
|
+
material.setRoughness(roughness) unless roughness.nil?
|
60
|
+
elsif material.to_MasslessOpaqueMaterial.is_initialized
|
61
|
+
material = material.to_MasslessOpaqueMaterial.get
|
62
|
+
material.setRoughness(roughness) unless roughness.nil?
|
63
|
+
end
|
64
|
+
material.setThermalAbsorptance(thermal_absorptance) unless thermal_absorptance.nil?
|
65
|
+
material.setSolarAbsorptance(solar_absorptance) unless solar_absorptance.nil?
|
66
|
+
material.setVisibleAbsorptance(visible_absorptance) unless visible_absorptance.nil?
|
67
|
+
|
68
|
+
return material.to_OpaqueMaterial.get
|
69
|
+
end
|
70
|
+
end
|
71
|
+
end
|
72
|
+
end
|
@@ -0,0 +1,80 @@
|
|
1
|
+
# Methods to modify construction properties
|
2
|
+
module OpenstudioStandards
|
3
|
+
module Constructions
|
4
|
+
# @!group Modify
|
5
|
+
|
6
|
+
# add new material layer to a construction
|
7
|
+
#
|
8
|
+
# @param construction [OpenStudio::Model::Construction] OpenStudio Construction object
|
9
|
+
# @param layer_index [Integer] the layer index, default is 0
|
10
|
+
# @param name [String] name of the new material layer
|
11
|
+
# @param roughness [String] surface roughness of the new material layer.
|
12
|
+
# Options are 'VeryRough', 'Rough', 'MediumRough', 'MediumSmooth', 'Smooth', and 'VerySmooth'
|
13
|
+
# @param thickness [Double] thickness of the new material layer in meters
|
14
|
+
# @param conductivity [Double] conductivity of new material layer in W/m*K
|
15
|
+
# @param density [Double] density of the new material layer in kg/m^3
|
16
|
+
# @param specific_heat [Double] specific heat of the new material layer in J/kg*K
|
17
|
+
# @param thermal_absorptance [Double] target thermal absorptance
|
18
|
+
# @param solar_absorptance [Double] target solar absorptance
|
19
|
+
# @param visible_absorptance [Double] target visible absorptance
|
20
|
+
# @return [OpenStudio::Model::StandardOpaqueMaterial] The new material layer, a OpenStudio StandardOpaqueMaterial object
|
21
|
+
def self.construction_add_new_opaque_material(construction,
|
22
|
+
layer_index: 0,
|
23
|
+
name: nil,
|
24
|
+
roughness: nil,
|
25
|
+
thickness: nil,
|
26
|
+
conductivity: nil,
|
27
|
+
density: nil,
|
28
|
+
specific_heat: nil,
|
29
|
+
thermal_absorptance: nil,
|
30
|
+
solar_absorptance: nil,
|
31
|
+
visible_absorptance: nil)
|
32
|
+
|
33
|
+
# make new material
|
34
|
+
new_material = OpenStudio::Model::StandardOpaqueMaterial.new(construction.model)
|
35
|
+
if name.nil?
|
36
|
+
new_material.setName("#{construction.name} New Material")
|
37
|
+
else
|
38
|
+
new_material.setName(name)
|
39
|
+
end
|
40
|
+
|
41
|
+
# set requested material properties
|
42
|
+
new_material.setRoughness(roughness) unless roughness.nil?
|
43
|
+
new_material.setThickness(thickness) unless thickness.nil?
|
44
|
+
new_material.setConductivity(conductivity) unless conductivity.nil?
|
45
|
+
new_material.setDensity(density) unless density.nil?
|
46
|
+
new_material.setSpecificHeat(specific_heat) unless specific_heat.nil?
|
47
|
+
new_material.setThermalAbsorptance(thermal_absorptance) unless thermal_absorptance.nil?
|
48
|
+
new_material.setSolarAbsorptance(solar_absorptance) unless solar_absorptance.nil?
|
49
|
+
new_material.setVisibleAbsorptance(visible_absorptance) unless visible_absorptance.nil?
|
50
|
+
|
51
|
+
# add material to construction
|
52
|
+
construction.insertLayer(layer_index, new_material)
|
53
|
+
|
54
|
+
return new_material
|
55
|
+
end
|
56
|
+
|
57
|
+
# set construction surface properties
|
58
|
+
#
|
59
|
+
# @param construction [OpenStudio::Model::Construction] OpenStudio Construction object
|
60
|
+
# @param roughness [String] surface roughness
|
61
|
+
# @param thermal_absorptance [Double] target thermal absorptance
|
62
|
+
# @param solar_absorptance [Double] target solar absorptance
|
63
|
+
# @param visible_absorptance [Double] target visible absorptance
|
64
|
+
# @return [OpenStudio::Model::OpaqueMaterial] OpenStudio OpaqueMaterial object
|
65
|
+
def self.construction_set_surface_properties(construction,
|
66
|
+
roughness: nil,
|
67
|
+
thermal_absorptance: nil,
|
68
|
+
solar_absorptance: nil,
|
69
|
+
visible_absorptance: nil)
|
70
|
+
|
71
|
+
surface_material = construction.to_LayeredConstruction.get.getLayer(0)
|
72
|
+
new_material = OpenstudioStandards::Constructions::Materials.opaque_material_set_surface_properties(surface_material,
|
73
|
+
roughness: roughness,
|
74
|
+
thermal_absorptance: thermal_absorptance,
|
75
|
+
solar_absorptance: solar_absorptance,
|
76
|
+
visible_absorptance: visible_absorptance)
|
77
|
+
return new_material
|
78
|
+
end
|
79
|
+
end
|
80
|
+
end
|