openstudio-standards 0.4.0 → 0.5.0

Sign up to get free protection for your applications and to get access to all the features.
Files changed (378) hide show
  1. checksums.yaml +4 -4
  2. data/LICENSE.md +33 -0
  3. data/data/inventory/thermal_bridging.csv +90 -0
  4. data/data/standards/OpenStudio_Standards-deer-comstock.xlsx +0 -0
  5. data/data/standards/manage_OpenStudio_Standards.rb +1 -1
  6. data/data/standards/test_performance_expected_dd_results.csv +2014 -1891
  7. data/lib/openstudio-standards/btap/analysis.rb +8 -8
  8. data/lib/openstudio-standards/btap/bridging.rb +664 -645
  9. data/lib/openstudio-standards/btap/btap.model.rb +14 -14
  10. data/lib/openstudio-standards/btap/btap.rb +7 -7
  11. data/lib/openstudio-standards/btap/btap_result.rb +1 -1
  12. data/lib/openstudio-standards/btap/economics.rb +23 -23
  13. data/lib/openstudio-standards/btap/envelope.rb +8 -8
  14. data/lib/openstudio-standards/btap/equest.rb +1 -1
  15. data/lib/openstudio-standards/btap/geometry.rb +2 -2
  16. data/lib/openstudio-standards/btap/mpc.rb +7 -7
  17. data/lib/openstudio-standards/btap/schedules.rb +1 -1
  18. data/lib/openstudio-standards/btap/simmanager.rb +4 -4
  19. data/lib/openstudio-standards/btap/spaceloads.rb +26 -26
  20. data/lib/openstudio-standards/btap/utilities.rb +6 -6
  21. data/lib/openstudio-standards/btap/vintagizer.rb +1 -1
  22. data/lib/openstudio-standards/constructions/information.rb +83 -0
  23. data/lib/openstudio-standards/constructions/materials/modify.rb +72 -0
  24. data/lib/openstudio-standards/constructions/modify.rb +80 -0
  25. data/lib/openstudio-standards/create_typical/create_typical.rb +983 -0
  26. data/lib/openstudio-standards/create_typical/enumerations.rb +484 -0
  27. data/lib/openstudio-standards/create_typical/space_type_blend.rb +791 -0
  28. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +494 -0
  29. data/lib/openstudio-standards/daylighting/space.rb +47 -0
  30. data/lib/openstudio-standards/geometry/create.rb +801 -0
  31. data/lib/openstudio-standards/geometry/create_bar.rb +2170 -0
  32. data/lib/openstudio-standards/geometry/information.rb +462 -0
  33. data/lib/openstudio-standards/geometry/modify.rb +48 -0
  34. data/lib/openstudio-standards/hvac/air_loop/information.rb +79 -0
  35. data/lib/openstudio-standards/hvac/cbecs_hvac.rb +616 -0
  36. data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +91 -0
  37. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
  38. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +1 -1
  39. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  40. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +1 -1
  41. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  42. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +2 -2
  43. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +1 -1
  44. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  45. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -36
  46. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +1 -1
  47. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  48. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -36
  49. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +3 -3
  50. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +1 -1
  51. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
  52. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +1 -1
  53. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +1 -1
  54. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +1 -1
  55. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +1 -1
  56. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  57. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  58. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +7 -7
  59. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +8 -8
  60. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +14 -14
  61. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +9 -9
  62. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +16 -16
  63. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +7 -7
  64. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +8 -8
  65. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +8 -8
  66. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +11 -11
  67. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +7 -7
  68. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +9 -9
  69. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +8 -8
  70. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +11 -11
  71. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +9 -9
  72. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +19 -19
  73. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +10 -10
  74. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +13 -13
  75. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +6 -6
  76. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +6 -6
  77. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -9
  78. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +8 -8
  79. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +8 -8
  80. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +8 -8
  81. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +8 -8
  82. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +11 -11
  83. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +10 -10
  84. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +19 -19
  85. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +18 -18
  86. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +6 -6
  87. data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +957 -957
  88. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +1 -1
  89. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +1 -1
  90. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +84 -16
  91. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
  92. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +1 -1
  93. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +61 -10
  94. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +1 -1
  95. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
  96. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +1 -1
  97. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -1
  98. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -1
  99. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +1 -1
  100. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +1 -1
  101. data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +2 -2
  102. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +4 -4
  103. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +4 -4
  104. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +43 -30
  105. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +1 -1
  106. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +18 -11
  107. data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +1 -1
  108. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +774 -117
  109. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +340 -481
  110. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +3 -3
  111. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +3 -3
  112. data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +22 -22
  113. data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
  114. data/lib/openstudio-standards/qaqc/calibration.rb +131 -0
  115. data/lib/openstudio-standards/qaqc/create_results.rb +983 -0
  116. data/lib/openstudio-standards/qaqc/envelope.rb +399 -0
  117. data/lib/openstudio-standards/qaqc/eui.rb +213 -0
  118. data/lib/openstudio-standards/qaqc/hvac.rb +1943 -0
  119. data/lib/openstudio-standards/qaqc/internal_loads.rb +568 -0
  120. data/lib/openstudio-standards/qaqc/reporting.rb +141 -0
  121. data/lib/openstudio-standards/qaqc/schedules.rb +129 -0
  122. data/lib/openstudio-standards/qaqc/service_water_heating.rb +273 -0
  123. data/lib/openstudio-standards/qaqc/weather_files.rb +497 -0
  124. data/lib/openstudio-standards/qaqc/zone_conditions.rb +278 -0
  125. data/lib/openstudio-standards/schedules/create.rb +364 -0
  126. data/lib/openstudio-standards/schedules/information.rb +169 -0
  127. data/lib/openstudio-standards/schedules/modify.rb +445 -0
  128. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +110 -71
  129. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
  130. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +4 -4
  131. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +2 -1
  132. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +16 -10
  133. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -4
  134. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +1 -1
  135. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
  136. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +4 -4
  137. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +1 -1
  138. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +5 -5
  139. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +1 -1
  140. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
  141. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
  142. data/lib/openstudio-standards/standards/Standards.Construction.rb +17 -18
  143. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +6 -6
  144. data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +1 -1
  145. data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +1 -1
  146. data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +1 -1
  147. data/lib/openstudio-standards/standards/Standards.Fan.rb +6 -12
  148. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -2
  149. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +1 -1
  150. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +1 -1
  151. data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +3 -3
  152. data/lib/openstudio-standards/standards/Standards.Model.rb +411 -261
  153. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -2
  154. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -29
  155. data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -2
  156. data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -2
  157. data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +14 -14
  158. data/lib/openstudio-standards/standards/Standards.Space.rb +37 -30
  159. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +38 -29
  160. data/lib/openstudio-standards/standards/Standards.SubSurface.rb +7 -7
  161. data/lib/openstudio-standards/standards/Standards.Surface.rb +13 -13
  162. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +109 -66
  163. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +11 -4
  164. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +6 -6
  165. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
  166. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +1 -1
  167. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +1 -1
  168. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +1 -1
  169. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +4 -4
  170. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  171. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +4 -4
  172. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +4 -4
  173. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  174. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +1 -1
  175. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +5 -21
  176. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +4 -4
  177. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
  178. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -1
  179. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +36 -4
  180. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  181. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +1 -1
  182. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +4 -4
  183. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -1
  184. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb +26 -0
  185. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +53 -10
  186. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  187. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +1 -1
  188. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +6 -6
  189. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +2 -2
  190. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb +26 -0
  191. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +211 -211
  192. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +14 -14
  193. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +4 -4
  194. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
  195. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +1 -1
  196. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +14 -14
  197. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +4 -4
  198. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
  199. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +1 -1
  200. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +6 -6
  201. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  202. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +1 -1
  203. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
  204. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +4 -4
  205. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +6 -6
  206. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  207. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +1 -1
  208. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
  209. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +4 -4
  210. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +22 -28
  211. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
  212. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat.rb +2 -2
  213. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater.rb +1 -74
  214. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +7 -59
  215. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +1 -1
  216. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
  217. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +1 -1
  218. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +1 -1
  219. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -21
  220. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb +101 -0
  221. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +1 -1
  222. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +1 -1
  223. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume.rb +1 -1
  224. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat.rb +1 -1
  225. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +643 -526
  226. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface.rb +8 -2
  227. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +17 -77
  228. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +74 -16
  229. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +96 -44
  230. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Surface.rb +6 -6
  231. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone.rb +18 -6
  232. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent.rb +1 -1
  233. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +328 -74
  234. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +0 -118
  235. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +2 -1
  236. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_rejection.json +1 -1
  237. data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md +35 -0
  238. data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_plug_load_measures.md +1 -1
  239. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +228 -0
  240. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +131 -0
  241. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_space.csv +1 -1
  242. data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +5 -5
  243. data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -1
  244. data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +1 -1
  245. data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +1 -1
  246. data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +1 -1
  247. data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +1 -1
  248. data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +109 -27
  249. data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
  250. data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.economizers.json +246 -4
  251. data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +246 -4
  252. data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.economizers.json +246 -4
  253. data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.ThermalZone.rb +18 -18
  254. data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.economizers.json +246 -4
  255. data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.ThermalZone.rb +18 -18
  256. data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.economizers.json +246 -4
  257. data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.ThermalZone.rb +18 -18
  258. data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.economizers.json +248 -6
  259. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +3 -3
  260. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.ThermalZone.rb +18 -18
  261. data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.economizers.json +248 -6
  262. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +3 -3
  263. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.ThermalZone.rb +18 -18
  264. data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.economizers.json +248 -6
  265. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +3 -3
  266. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.ThermalZone.rb +18 -18
  267. data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.economizers.json +248 -6
  268. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +18 -5
  269. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
  270. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +3 -3
  271. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.ThermalZone.rb +18 -18
  272. data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.economizers.json +248 -6
  273. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +3 -3
  274. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
  275. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +3 -3
  276. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.economizers.json +248 -6
  277. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps.json +2 -2
  278. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +3 -3
  279. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
  280. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +3 -3
  281. data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.economizers.json +248 -6
  282. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +3 -3
  283. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
  284. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +3 -3
  285. data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.economizers.json +248 -6
  286. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +3 -3
  287. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
  288. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +3 -3
  289. data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json +260 -0
  290. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +3 -3
  291. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
  292. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +3 -3
  293. data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.economizers.json +248 -6
  294. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +3 -3
  295. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
  296. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +3 -3
  297. data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.economizers.json +248 -6
  298. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +3 -3
  299. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
  300. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +3 -3
  301. data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.economizers.json +248 -6
  302. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +3 -3
  303. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
  304. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +3 -3
  305. data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.economizers.json +248 -6
  306. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +3 -3
  307. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
  308. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +3 -3
  309. data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.economizers.json +248 -6
  310. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +3 -3
  311. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
  312. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +3 -3
  313. data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.economizers.json +248 -6
  314. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +3 -3
  315. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
  316. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +3 -3
  317. data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.economizers.json +246 -4
  318. data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +447 -223
  319. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +1 -1
  320. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +447 -223
  321. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +5 -2
  322. data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json +25 -0
  323. data/lib/openstudio-standards/standards/necb/ECMS/data/chillers.json +44 -0
  324. data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +225 -0
  325. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +2 -2
  326. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +193 -73
  327. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +1 -1
  328. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +10 -4
  329. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +7 -7
  330. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +4 -5
  331. data/lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json +32 -0
  332. data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +1 -1
  333. data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +36 -0
  334. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -7
  335. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm +47587 -0
  336. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm +49764 -0
  337. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Warehouse.osm +283 -297
  338. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_type_unit_definitions.txt +2 -1
  339. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +447 -223
  340. data/lib/openstudio-standards/standards/necb/NECB2011/data/standards_data.rb +3 -3
  341. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +1 -1
  342. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +49 -27
  343. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +400 -202
  344. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -4
  345. data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +637 -318
  346. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +18 -1
  347. data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +3 -3
  348. data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +637 -318
  349. data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -1
  350. data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +3 -3
  351. data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +1 -1
  352. data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +615 -307
  353. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +4 -4
  354. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +10 -5
  355. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +1 -1
  356. data/lib/openstudio-standards/utilities/assertion.rb +128 -0
  357. data/lib/openstudio-standards/utilities/logging.rb +2 -3
  358. data/lib/openstudio-standards/utilities/object_info.rb +39 -18
  359. data/lib/openstudio-standards/utilities/schedule_translator.rb +8 -6
  360. data/lib/openstudio-standards/utilities/simulation.rb +24 -11
  361. data/lib/openstudio-standards/utilities/sqlfile.rb +10 -5
  362. data/lib/openstudio-standards/version.rb +1 -1
  363. data/lib/openstudio-standards/weather/Weather.Model.rb +8 -9
  364. data/lib/openstudio-standards/weather/Weather.stat_file.rb +3 -3
  365. data/lib/openstudio-standards/weather/information.rb +35 -0
  366. data/lib/openstudio-standards.rb +69 -5
  367. metadata +54 -18
  368. data/License.txt +0 -65
  369. data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
  370. data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +0 -59
  371. data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb +0 -13
  372. data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +0 -36
  373. data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +0 -898
  374. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +0 -126
  375. data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +0 -356
  376. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +0 -35
  377. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb +0 -110
  378. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb +0 -5
@@ -63,7 +63,7 @@
63
63
  #
64
64
  # #This method will scale people loads.
65
65
  # #@author phylroy.lopez@nrcan.gc.ca
66
- # #@param model [OpenStudio::model::Model] A model object
66
+ # #@param model [OpenStudio::Model::Model] A model object
67
67
  # #@param factor [Float]
68
68
  # def self.scale_people_loads( model, factor )
69
69
  # model.getPeoples.sort.each do |item|
@@ -73,7 +73,7 @@
73
73
  #
74
74
  # #This method will scale people loads schedule.
75
75
  # #@author phylroy.lopez@nrcan.gc.ca
76
- # #@param model [OpenStudio::model::Model] A model object
76
+ # #@param model [OpenStudio::Model::Model] A model object
77
77
  # #@param a_coef [Float]
78
78
  # #@param b_coef [Float]
79
79
  # #@param c_coef [Float]
@@ -88,7 +88,7 @@
88
88
  #
89
89
  # #This method will scale lighting loads.
90
90
  # #@author phylroy.lopez@nrcan.gc.ca
91
- # #@param model [OpenStudio::model::Model] A model object
91
+ # #@param model [OpenStudio::Model::Model] A model object
92
92
  # #@param factor [Float]
93
93
  # def self.scale_lighting_loads( model, factor )
94
94
  # model.getLightss.sort.each do |item|
@@ -98,7 +98,7 @@
98
98
  #
99
99
  # #This method will scale lighting loads schedule.
100
100
  # #@author phylroy.lopez@nrcan.gc.ca
101
- # #@param model [OpenStudio::model::Model] A model object
101
+ # #@param model [OpenStudio::Model::Model] A model object
102
102
  # #@param a_coef [Float]
103
103
  # #@param b_coef [Float]
104
104
  # #@param c_coef [Float]
@@ -113,7 +113,7 @@
113
113
  #
114
114
  # #This method will scale electrical loads.
115
115
  # #@author phylroy.lopez@nrcan.gc.ca
116
- # #@param model [OpenStudio::model::Model] A model object
116
+ # #@param model [OpenStudio::Model::Model] A model object
117
117
  # #@param factor [Float]
118
118
  # def self.scale_electrical_loads( model, factor )
119
119
  # model.getElectricEquipments.sort.each do |item|
@@ -123,7 +123,7 @@
123
123
  #
124
124
  # #This method will scale electrical loads schedule.
125
125
  # #@author phylroy.lopez@nrcan.gc.ca
126
- # #@param model [OpenStudio::model::Model] A model object
126
+ # #@param model [OpenStudio::Model::Model] A model object
127
127
  # #@param a_coef [Float]
128
128
  # #@param b_coef [Float]
129
129
  # #@param c_coef [Float]
@@ -137,7 +137,7 @@
137
137
  #
138
138
  # #This method will scale hotwater loads.
139
139
  # #@author phylroy.lopez@nrcan.gc.ca
140
- # #@param model [OpenStudio::model::Model] A model object
140
+ # #@param model [OpenStudio::Model::Model] A model object
141
141
  # #@param factor [Float]
142
142
  # def self.scale_hot_water_loads( model, factor )
143
143
  # model.getHotWaterEquipments.sort.each do |item|
@@ -147,7 +147,7 @@
147
147
  #
148
148
  # #This method will scale Outdoor Air loads.
149
149
  # #@author phylroy.lopez@nrcan.gc.ca
150
- # #@param model [OpenStudio::model::Model] A model object
150
+ # #@param model [OpenStudio::Model::Model] A model object
151
151
  # #@param factor [Float]
152
152
  # def self.scale_oa_loads( model, factor )
153
153
  # model.getDesignSpecificationOutdoorAirs.sort.each do |oa_def|
@@ -160,7 +160,7 @@
160
160
  #
161
161
  # #This method will scale infiltration loads.
162
162
  # #@author phylroy.lopez@nrcan.gc.ca
163
- # #@param model [OpenStudio::model::Model] A model object
163
+ # #@param model [OpenStudio::Model::Model] A model object
164
164
  # #@param factor [Float]
165
165
  # def self.scale_inflitration_loads( model, factor )
166
166
  # model.getSpaceInfiltrationDesignFlowRates.sort.each do |infiltration_load|
@@ -173,7 +173,7 @@
173
173
  #
174
174
  # #This method will set the infiltration magnitude.
175
175
  # #@author phylroy.lopez@nrcan.gc.ca
176
- # #@param model [OpenStudio::model::Model] A model object
176
+ # #@param model [OpenStudio::Model::Model] A model object
177
177
  # #@param setDesignFlowRate [Float]
178
178
  # #@param setFlowperSpaceFloorArea [Float]
179
179
  # #@param setFlowperExteriorSurfaceArea [Float]
@@ -202,7 +202,7 @@
202
202
  #
203
203
  # #This method removes people loads from the model.
204
204
  # #@author phylroy.lopez@nrcan.gc.ca
205
- # #@param model [OpenStudio::model::Model] A model object
205
+ # #@param model [OpenStudio::Model::Model] A model object
206
206
  # def self.remove_all_people_loads(model)
207
207
  # model.getPeoples.sort.each {|people| people.remove}
208
208
  # model.getPeopleDefinitions.sort.each {|people| people.remove}
@@ -211,7 +211,7 @@
211
211
  #
212
212
  # #This method created people loads from the model.
213
213
  # #@author phylroy.lopez@nrcan.gc.ca
214
- # #@param model [OpenStudio::model::Model] A model object
214
+ # #@param model [OpenStudio::Model::Model] A model object
215
215
  # #@param people_name [String]
216
216
  # #@param floor_area_per_person [Float]
217
217
  # #@param multiplier [Float]
@@ -239,7 +239,7 @@
239
239
  #
240
240
  # #This method removes light loads from model.
241
241
  # #@author phylroy.lopez@nrcan.gc.ca
242
- # #@param model [OpenStudio::model::Model] A model object
242
+ # #@param model [OpenStudio::Model::Model] A model object
243
243
  # def self.remove_all_light_loads(model)
244
244
  # model.getLightss.sort.each {|item| item.remove}
245
245
  # model.getLightsDefinitions.sort.each {|item| item.remove}
@@ -247,7 +247,7 @@
247
247
  #
248
248
  # #This method created people loads from the model.
249
249
  # #@author phylroy.lopez@nrcan.gc.ca
250
- # #@param model [OpenStudio::model::Model] A model object
250
+ # #@param model [OpenStudio::Model::Model] A model object
251
251
  # #@param light_name [String]
252
252
  # #@param light_watts_per_floor_area [Float]
253
253
  # #@param multiplier [Float]
@@ -268,7 +268,7 @@
268
268
  #
269
269
  # #This method removes elec loads from model.
270
270
  # #@author phylroy.lopez@nrcan.gc.ca
271
- # #@param model [OpenStudio::model::Model] A model object
271
+ # #@param model [OpenStudio::Model::Model] A model object
272
272
  # def self.remove_all_electric_loads(model)
273
273
  # model.getElectricEquipments.sort.each {|item| item.remove}
274
274
  # model.getElectricEquipmentDefinitions.sort.each {|item| item.remove}
@@ -277,7 +277,7 @@
277
277
  #
278
278
  # #This method created people loads from the model.
279
279
  # #@author phylroy.lopez@nrcan.gc.ca
280
- # #@param model [OpenStudio::model::Model] A model object
280
+ # #@param model [OpenStudio::Model::Model] A model object
281
281
  # #@param elec_name [String]
282
282
  # #@param elec_watts_per_floor_area [Float]
283
283
  # #@param multiplier [Float]
@@ -297,7 +297,7 @@
297
297
  #
298
298
  # #This method removes hot water loads from model.
299
299
  # #@author phylroy.lopez@nrcan.gc.ca
300
- # #@param model [OpenStudio::model::Model] A model object
300
+ # #@param model [OpenStudio::Model::Model] A model object
301
301
  # def self.remove_all_hot_water_loads(model)
302
302
  # model.getHotWaterEquipments.sort.each {|item| item.remove}
303
303
  # model.getHotWaterEquipmentDefinitions.sort.each {|item| item.remove}
@@ -305,7 +305,7 @@
305
305
  #
306
306
  # #This method creats hot water load.
307
307
  # #@author phylroy.lopez@nrcan.gc.ca
308
- # #@param model [OpenStudio::model::Model] A model object
308
+ # #@param model [OpenStudio::Model::Model] A model object
309
309
  # #@param hot_water_name [String]
310
310
  # #@param hot_water_watts_per_floor_area [Float]
311
311
  # #@param multiplier [Float]
@@ -326,7 +326,7 @@
326
326
  #
327
327
  # #This method removes all design specification OA from model.
328
328
  # #@author phylroy.lopez@nrcan.gc.ca
329
- # #@param model [OpenStudio::model::Model] A model object
329
+ # #@param model [OpenStudio::Model::Model] A model object
330
330
  # def self.remove_all_DesignSpecificationOutdoorAir(model)
331
331
  # model.getDesignSpecificationOutdoorAirs.sort.each { |item| item.remove }
332
332
  # end
@@ -334,7 +334,7 @@
334
334
  #
335
335
  # #This method removes all space infiltration design flow rate OA from model.
336
336
  # #@author phylroy.lopez@nrcan.gc.ca
337
- # #@param model [OpenStudio::model::Model] A model object
337
+ # #@param model [OpenStudio::Model::Model] A model object
338
338
  # def self.remove_all_SpaceInfiltrationDesignFlowRate(model)
339
339
  # OpenStudio::Model::SpaceInfiltrationDesignFlowRate
340
340
  # model.getSpaceInfiltrationDesignFlowRates.sort.each { |item| item.remove }
@@ -342,7 +342,7 @@
342
342
  #
343
343
  # #This method creats hot water load.
344
344
  # #@author phylroy.lopez@nrcan.gc.ca
345
- # #@param model [OpenStudio::model::Model] A model object
345
+ # #@param model [OpenStudio::Model::Model] A model object
346
346
  # #@param oa_name [String]
347
347
  # #@param oa_person [Fixnum]
348
348
  # #@param oa_area [Fixnum]
@@ -350,7 +350,7 @@
350
350
  # #@param oa_flowrate [Fixnum]
351
351
  # #@param method [String]
352
352
  # #@param schedule [Float]
353
- # #@return [OpenStudio::model::Model] oa_def
353
+ # #@return [OpenStudio::Model::Model] oa_def
354
354
  # def self.create_oa_load(model,oa_name,oa_person = 0 ,oa_area = 0, oa_ach = 0, oa_flowrate = 0, method = "Maximum",schedule = nil)
355
355
  # raise("DesignSpecificationOutdoorAir #{name} already exists. Please use a different name") unless model.getDesignSpecificationOutdoorAirByName( oa_name ).empty?
356
356
  # #units are in m3/s for flow and m2 for area.
@@ -373,7 +373,7 @@
373
373
  #
374
374
  # #This method removes infiltration from model..
375
375
  # #@author phylroy.lopez@nrcan.gc.ca
376
- # #@param model [OpenStudio::model::Model] A model object
376
+ # #@param model [OpenStudio::Model::Model] A model object
377
377
  # def self.remove_all_SpaceInfiltrationDesignFlowRates(model)
378
378
  # model.getSpaceInfiltrationDesignFlowRates.sort.each { |item| item.remove }
379
379
  # end
@@ -381,7 +381,7 @@
381
381
  # #This method creates infiltration load.
382
382
  # #NECB infiltration rate is 0.25L/s/m2 or 0.00025 m3/s/m2
383
383
  # #@author phylroy.lopez@nrcan.gc.ca
384
- # #@param model [OpenStudio::model::Model] A model object
384
+ # #@param model [OpenStudio::Model::Model] A model object
385
385
  # #@return [String] infiltration_load
386
386
  # def self.create_infiltration_load(model,
387
387
  # infil_name,
@@ -419,7 +419,7 @@
419
419
  #
420
420
  # #This method removes all loads from model.
421
421
  # #@author phylroy.lopez@nrcan.gc.ca
422
- # #@param model [OpenStudio::model::Model] A model object
422
+ # #@param model [OpenStudio::Model::Model] A model object
423
423
  # def self.remove_all_casual_loads(model)
424
424
  # self.remove_all_people_loads(model)
425
425
  # self.remove_all_light_loads(model)
@@ -429,7 +429,7 @@
429
429
  #
430
430
  # #This method removes all space loads from model.
431
431
  # #@author phylroy.lopez@nrcan.gc.ca
432
- # #@param model [OpenStudio::model::Model] A model object
432
+ # #@param model [OpenStudio::Model::Model] A model object
433
433
  # def self.remove_all_SpaceLoads(model)
434
434
  # model.getSpaceLoads.sort.each { |item| item.remove }
435
435
  # model.getSpaceLoadDefinitions.sort.each { |item| item.remove }
@@ -49,9 +49,9 @@
49
49
  # #argument model(s). This is handy for quickly viewing changes to the file during
50
50
  # #runtime for debugging and QA.
51
51
  # #@author phylroy.lopez@nrcan.gc.ca
52
- # #@param model1 [OpenStudio::model::Model] A model object.
53
- # #@param model2 [OpenStudio::model::Model] A model object.
54
- # #@param model3 [OpenStudio::model::Model] A model object.
52
+ # #@param model1 [OpenStudio::Model::Model] A model object.
53
+ # #@param model2 [OpenStudio::Model::Model] A model object.
54
+ # #@param model3 [OpenStudio::Model::Model] A model object.
55
55
  # def self.kdiff3_model_osm(model1, model2, model3 = "")
56
56
  # Dir::mkdir("C:\\kdiff_test") unless File.exists?("C:\\kdiff_test")
57
57
  # model1.save(OpenStudio::Path.new("c:\\kdiff_test\\diffA.osm"))
@@ -71,9 +71,9 @@
71
71
  # #argument model(s). This is handy for quickly viewing changes to the file during
72
72
  # #runtime for debugging and QA.
73
73
  # #@author phylroy.lopez@nrcan.gc.ca
74
- # #@param model1 [OpenStudio::model::Model] A model object.
75
- # #@param model2 [OpenStudio::model::Model] A model object.
76
- # #@param model3 [OpenStudio::model::Model] A model object.
74
+ # #@param model1 [OpenStudio::Model::Model] A model object.
75
+ # #@param model2 [OpenStudio::Model::Model] A model object.
76
+ # #@param model3 [OpenStudio::Model::Model] A model object.
77
77
  # def self.kdiff3_model_idf(model1, model2, model3 = "")
78
78
  # Dir::mkdir("C:\\kdiff_test") unless File.exists?("C:\\kdiff_test")
79
79
  #
@@ -24,7 +24,7 @@ class Vintagizer
24
24
 
25
25
  #This method loads Vintage database information.
26
26
  #@author phylroy.lopez@nrcan.gc.ca
27
- #@param model [OpenStudio::model::Model] A model object
27
+ #@param model [OpenStudio::Model::Model] A model object
28
28
  #@param file [String]
29
29
  #@param selectionHash [???]
30
30
  def initialize(model,file,selectionHash)
@@ -0,0 +1,83 @@
1
+ # Methods to create typical models
2
+ module OpenstudioStandards
3
+ module Constructions
4
+ # @!group Information
5
+
6
+ # Returns the solar reflectance index of an exposed surface.
7
+ # On a scale of 0 to 100, standard black is 0, and standard white is 100.
8
+ # The calculation derived from ASTM E1980 assuming medium wind speed.
9
+ #
10
+ # @param construction [OpenStudio::Model::Construction] OpenStudio Construction object
11
+ # @return [Double] The solar reflectance value
12
+ def self.construction_get_solar_reflectance_index(construction)
13
+ exposed_material = construction.to_LayeredConstruction.get.getLayer(0)
14
+ solar_absorptance = exposed_material.to_OpaqueMaterial.get.solarAbsorptance
15
+ thermal_emissivity = exposed_material.to_OpaqueMaterial.get.thermalAbsorptance
16
+ x = (20.797 * solar_absorptance - 0.603 * thermal_emissivity) / (9.5205 * thermal_emissivity + 12.0)
17
+ sri = 123.97 - 141.35 * x + 9.6555 * x * x
18
+
19
+ return sri
20
+ end
21
+
22
+ # report names of constructions in a construction set
23
+ #
24
+ # @param default_construction_set [OpenStudio::Model::Defaultdefault_construction_set] OpenStudio Defaultdefault_construction_set object
25
+ # @return [Array<OpenStudio::Model::Construction>] Array of OpenStudio Construction objects
26
+ def self.construction_set_get_constructions(default_construction_set)
27
+ construction_array = []
28
+
29
+ # populate exterior surfaces
30
+ if default_construction_set.defaultExteriorSurfaceConstructions.is_initialized
31
+ default_surface_constructions = default_construction_set.defaultExteriorSurfaceConstructions.get
32
+ construction_array << default_surface_constructions.floorConstruction.get if default_surface_constructions.floorConstruction.is_initialized
33
+ construction_array << default_surface_constructions.wallConstruction.get if default_surface_constructions.wallConstruction.is_initialized
34
+ construction_array << default_surface_constructions.roofCeilingConstruction.get if default_surface_constructions.roofCeilingConstruction.is_initialized
35
+ end
36
+ # populate interior surfaces
37
+ if default_construction_set.defaultInteriorSurfaceConstructions.is_initialized
38
+ default_surface_constructions = default_construction_set.defaultInteriorSurfaceConstructions.get
39
+ construction_array << default_surface_constructions.floorConstruction.get if default_surface_constructions.floorConstruction.is_initialized
40
+ construction_array << default_surface_constructions.wallConstruction.get if default_surface_constructions.wallConstruction.is_initialized
41
+ construction_array << default_surface_constructions.roofCeilingConstruction.get if default_surface_constructions.roofCeilingConstruction.is_initialized
42
+ end
43
+ # populate ground surfaces
44
+ if default_construction_set.defaultGroundContactSurfaceConstructions.is_initialized
45
+ default_surface_constructions = default_construction_set.defaultGroundContactSurfaceConstructions.get
46
+ construction_array << default_surface_constructions.floorConstruction.get if default_surface_constructions.floorConstruction.is_initialized
47
+ construction_array << default_surface_constructions.wallConstruction.get if default_surface_constructions.wallConstruction.is_initialized
48
+ construction_array << default_surface_constructions.roofCeilingConstruction.get if default_surface_constructions.roofCeilingConstruction.is_initialized
49
+ end
50
+ # populate exterior sub-surfaces
51
+ if default_construction_set.defaultExteriorSubSurfaceConstructions.is_initialized
52
+ default_subsurface_constructions = default_construction_set.defaultExteriorSubSurfaceConstructions.get
53
+ construction_array << default_subsurface_constructions.fixedWindowConstruction.get if default_subsurface_constructions.fixedWindowConstruction.is_initialized
54
+ construction_array << default_subsurface_constructions.operableWindowConstruction.get if default_subsurface_constructions.operableWindowConstruction.is_initialized
55
+ construction_array << default_subsurface_constructions.doorConstruction.get if default_subsurface_constructions.doorConstruction.is_initialized
56
+ construction_array << default_subsurface_constructions.glassDoorConstruction.get if default_subsurface_constructions.glassDoorConstruction.is_initialized
57
+ construction_array << default_subsurface_constructions.overheadDoorConstruction.get if default_subsurface_constructions.overheadDoorConstruction.is_initialized
58
+ construction_array << default_subsurface_constructions.skylightConstruction.get if default_subsurface_constructions.skylightConstruction.is_initialized
59
+ construction_array << default_subsurface_constructions.tubularDaylightDomeConstruction.get if default_subsurface_constructions.tubularDaylightDomeConstruction.is_initialized
60
+ construction_array << default_subsurface_constructions.tubularDaylightDiffuserConstruction.get if default_subsurface_constructions.tubularDaylightDiffuserConstruction.is_initialized
61
+ end
62
+ # populate interior sub-surfaces
63
+ if default_construction_set.defaultInteriorSubSurfaceConstructions.is_initialized
64
+ default_subsurface_constructions = default_construction_set.defaultInteriorSubSurfaceConstructions.get
65
+ construction_array << default_subsurface_constructions.fixedWindowConstruction.get if default_subsurface_constructions.fixedWindowConstruction.is_initialized
66
+ construction_array << default_subsurface_constructions.operableWindowConstruction.get if default_subsurface_constructions.operableWindowConstruction.is_initialized
67
+ construction_array << default_subsurface_constructions.doorConstruction.get if default_subsurface_constructions.doorConstruction.is_initialized
68
+ construction_array << default_subsurface_constructions.glassDoorConstruction.get if default_subsurface_constructions.glassDoorConstruction.is_initialized
69
+ construction_array << default_subsurface_constructions.overheadDoorConstruction.get if default_subsurface_constructions.overheadDoorConstruction.is_initialized
70
+ construction_array << default_subsurface_constructions.skylightConstruction.get if default_subsurface_constructions.skylightConstruction.is_initialized
71
+ construction_array << default_subsurface_constructions.tubularDaylightDomeConstruction.get if default_subsurface_constructions.tubularDaylightDomeConstruction.is_initialized
72
+ construction_array << default_subsurface_constructions.tubularDaylightDiffuserConstruction.get if default_subsurface_constructions.tubularDaylightDiffuserConstruction.is_initialized
73
+ end
74
+ # populate misc surfaces
75
+ construction_array << default_construction_set.interiorPartitionConstruction.get if default_construction_set.interiorPartitionConstruction.is_initialized
76
+ construction_array << default_construction_set.spaceShadingConstruction.get if default_construction_set.spaceShadingConstruction.is_initialized
77
+ construction_array << default_construction_set.buildingShadingConstruction.get if default_construction_set.buildingShadingConstruction.is_initialized
78
+ construction_array << default_construction_set.siteShadingConstruction.get if default_construction_set.siteShadingConstruction.is_initialized
79
+
80
+ return construction_array
81
+ end
82
+ end
83
+ end
@@ -0,0 +1,72 @@
1
+ # Methods to modify material properties
2
+ module OpenstudioStandards
3
+ module Constructions
4
+ module Materials
5
+ # @!group Modify
6
+
7
+ # change thermal resistance of opaque materials by increasing material thickness,
8
+ # or setting thermal resistance directly for massless or airgap materials.
9
+ #
10
+ # @param opaque_material [OpenStudio::Model::OpaqueMaterial] OpenStudio OpaqueMaterial object
11
+ # @param thermal_resistance [Double] Target thermal resistance of the material in m^2*K/W
12
+ # @return [OpenStudio::Model::OpaqueMaterial] OpenStudio OpaqueMaterial object
13
+ def self.opaque_material_set_thermal_resistance(opaque_material, thermal_resistance)
14
+ unless opaque_material.to_OpaqueMaterial.is_initialized
15
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.constructions.materials', "Object #{opaque_material} cannot be cast as an OpaqueMaterial object.")
16
+ return false
17
+ end
18
+
19
+ # edit insulation material
20
+ material = opaque_material.to_OpaqueMaterial.get
21
+ if material.to_MasslessOpaqueMaterial.is_initialized
22
+ material = material.to_MasslessOpaqueMaterial.get
23
+ material.setThermalResistance(thermal_resistance)
24
+ elsif material.to_AirGap.is_initialized
25
+ material = material.to_AirGap.get
26
+ material.setThermalResistance(thermal_resistance)
27
+ else
28
+ starting_thickness = material.thickness
29
+ target_thickness = starting_thickness * thermal_resistance / material.thermalResistance
30
+ material.setThickness(target_thickness)
31
+ end
32
+
33
+ return material.to_OpaqueMaterial.get
34
+ end
35
+
36
+ # set material surface properties
37
+ #
38
+ # @param opaque_material [OpenStudio::Model::OpaqueMaterial] OpenStudio OpaqueMaterial object
39
+ # @param roughness [String] surface roughness. Options are 'VeryRough', 'Rough', 'MediumRough',
40
+ # 'MediumSmooth', 'Smooth', and 'VerySmooth'
41
+ # @param thermal_absorptance [Double] target thermal absorptance
42
+ # @param solar_absorptance [Double] target solar absorptance
43
+ # @param visible_absorptance [Double] target visible absorptance
44
+ # @return [OpenStudio::Model::OpaqueMaterial] OpenStudio OpaqueMaterial object
45
+ def self.opaque_material_set_surface_properties(opaque_material,
46
+ roughness: nil,
47
+ thermal_absorptance: nil,
48
+ solar_absorptance: nil,
49
+ visible_absorptance: nil)
50
+ unless opaque_material.to_OpaqueMaterial.is_initialized
51
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.constructions.materials', "Object #{opaque_material} cannot be cast as an OpaqueMaterial object.")
52
+ return false
53
+ end
54
+
55
+ # set requested material properties
56
+ material = opaque_material.to_OpaqueMaterial.get
57
+ if material.to_StandardOpaqueMaterial.is_initialized
58
+ material = material.to_StandardOpaqueMaterial.get
59
+ material.setRoughness(roughness) unless roughness.nil?
60
+ elsif material.to_MasslessOpaqueMaterial.is_initialized
61
+ material = material.to_MasslessOpaqueMaterial.get
62
+ material.setRoughness(roughness) unless roughness.nil?
63
+ end
64
+ material.setThermalAbsorptance(thermal_absorptance) unless thermal_absorptance.nil?
65
+ material.setSolarAbsorptance(solar_absorptance) unless solar_absorptance.nil?
66
+ material.setVisibleAbsorptance(visible_absorptance) unless visible_absorptance.nil?
67
+
68
+ return material.to_OpaqueMaterial.get
69
+ end
70
+ end
71
+ end
72
+ end
@@ -0,0 +1,80 @@
1
+ # Methods to modify construction properties
2
+ module OpenstudioStandards
3
+ module Constructions
4
+ # @!group Modify
5
+
6
+ # add new material layer to a construction
7
+ #
8
+ # @param construction [OpenStudio::Model::Construction] OpenStudio Construction object
9
+ # @param layer_index [Integer] the layer index, default is 0
10
+ # @param name [String] name of the new material layer
11
+ # @param roughness [String] surface roughness of the new material layer.
12
+ # Options are 'VeryRough', 'Rough', 'MediumRough', 'MediumSmooth', 'Smooth', and 'VerySmooth'
13
+ # @param thickness [Double] thickness of the new material layer in meters
14
+ # @param conductivity [Double] conductivity of new material layer in W/m*K
15
+ # @param density [Double] density of the new material layer in kg/m^3
16
+ # @param specific_heat [Double] specific heat of the new material layer in J/kg*K
17
+ # @param thermal_absorptance [Double] target thermal absorptance
18
+ # @param solar_absorptance [Double] target solar absorptance
19
+ # @param visible_absorptance [Double] target visible absorptance
20
+ # @return [OpenStudio::Model::StandardOpaqueMaterial] The new material layer, a OpenStudio StandardOpaqueMaterial object
21
+ def self.construction_add_new_opaque_material(construction,
22
+ layer_index: 0,
23
+ name: nil,
24
+ roughness: nil,
25
+ thickness: nil,
26
+ conductivity: nil,
27
+ density: nil,
28
+ specific_heat: nil,
29
+ thermal_absorptance: nil,
30
+ solar_absorptance: nil,
31
+ visible_absorptance: nil)
32
+
33
+ # make new material
34
+ new_material = OpenStudio::Model::StandardOpaqueMaterial.new(construction.model)
35
+ if name.nil?
36
+ new_material.setName("#{construction.name} New Material")
37
+ else
38
+ new_material.setName(name)
39
+ end
40
+
41
+ # set requested material properties
42
+ new_material.setRoughness(roughness) unless roughness.nil?
43
+ new_material.setThickness(thickness) unless thickness.nil?
44
+ new_material.setConductivity(conductivity) unless conductivity.nil?
45
+ new_material.setDensity(density) unless density.nil?
46
+ new_material.setSpecificHeat(specific_heat) unless specific_heat.nil?
47
+ new_material.setThermalAbsorptance(thermal_absorptance) unless thermal_absorptance.nil?
48
+ new_material.setSolarAbsorptance(solar_absorptance) unless solar_absorptance.nil?
49
+ new_material.setVisibleAbsorptance(visible_absorptance) unless visible_absorptance.nil?
50
+
51
+ # add material to construction
52
+ construction.insertLayer(layer_index, new_material)
53
+
54
+ return new_material
55
+ end
56
+
57
+ # set construction surface properties
58
+ #
59
+ # @param construction [OpenStudio::Model::Construction] OpenStudio Construction object
60
+ # @param roughness [String] surface roughness
61
+ # @param thermal_absorptance [Double] target thermal absorptance
62
+ # @param solar_absorptance [Double] target solar absorptance
63
+ # @param visible_absorptance [Double] target visible absorptance
64
+ # @return [OpenStudio::Model::OpaqueMaterial] OpenStudio OpaqueMaterial object
65
+ def self.construction_set_surface_properties(construction,
66
+ roughness: nil,
67
+ thermal_absorptance: nil,
68
+ solar_absorptance: nil,
69
+ visible_absorptance: nil)
70
+
71
+ surface_material = construction.to_LayeredConstruction.get.getLayer(0)
72
+ new_material = OpenstudioStandards::Constructions::Materials.opaque_material_set_surface_properties(surface_material,
73
+ roughness: roughness,
74
+ thermal_absorptance: thermal_absorptance,
75
+ solar_absorptance: solar_absorptance,
76
+ visible_absorptance: visible_absorptance)
77
+ return new_material
78
+ end
79
+ end
80
+ end