openstudio-standards 0.2.12.rc5 → 0.2.13

Sign up to get free protection for your applications and to get access to all the features.
Files changed (509) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAE90120162019HighriseApartment.json +1042 -0
  3. data/data/geometry/ASHRAE90120162019Hospital.json +199 -0
  4. data/data/geometry/ASHRAE90120162019LargeHotel.json +73 -0
  5. data/data/geometry/ASHRAE90120162019LargeOffice.json +109 -0
  6. data/data/geometry/ASHRAE90120162019SecondarySchool.json +205 -0
  7. data/data/geometry/ASHRAECourthouse.json +112 -0
  8. data/data/geometry/ASHRAECourthouse.osm +26470 -0
  9. data/data/geometry/ASHRAELargeHotel.osm +11 -1
  10. data/data/geometry/ASHRAELargeOffice.json +4 -0
  11. data/data/geometry/ASHRAESmallDataCenter.json +1 -1
  12. data/data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx +0 -0
  13. data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
  14. data/data/standards/exclude_list.csv +19 -0
  15. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +49 -0
  16. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +293 -0
  17. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +25426 -0
  18. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +1600 -0
  19. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +564 -0
  20. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +349 -0
  21. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +164 -0
  22. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +10663 -0
  23. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +508 -0
  24. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +156 -0
  25. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +44 -0
  26. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +184 -0
  27. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +3094 -0
  28. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +829 -0
  29. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +562 -0
  30. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +52 -0
  31. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +220 -0
  32. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +156 -0
  33. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +1316 -0
  34. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +21446 -0
  35. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +554 -0
  36. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +68 -0
  37. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +28 -0
  38. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +12 -0
  39. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +49 -0
  40. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +293 -0
  41. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +12487 -0
  42. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +1600 -0
  43. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +564 -0
  44. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +349 -0
  45. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +164 -0
  46. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +10663 -0
  47. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +466 -0
  48. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +137 -0
  49. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +44 -0
  50. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +184 -0
  51. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +3094 -0
  52. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +829 -0
  53. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +562 -0
  54. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +52 -0
  55. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +220 -0
  56. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +156 -0
  57. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +1316 -0
  58. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +21380 -0
  59. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +554 -0
  60. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +68 -0
  61. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +28 -0
  62. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +12 -0
  63. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +49 -0
  64. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +395 -0
  65. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +12487 -0
  66. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +1600 -0
  67. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +592 -0
  68. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +349 -0
  69. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +550 -0
  70. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +164 -0
  71. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +10663 -0
  72. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +466 -0
  73. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +137 -0
  74. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +44 -0
  75. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +238 -0
  76. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +3094 -0
  77. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +829 -0
  78. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +562 -0
  79. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +52 -0
  80. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +220 -0
  81. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +156 -0
  82. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +1316 -0
  83. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +21548 -0
  84. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +554 -0
  85. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +68 -0
  86. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +28 -0
  87. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +12 -0
  88. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +64 -0
  89. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +871 -0
  90. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +12487 -0
  91. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +1600 -0
  92. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +592 -0
  93. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +349 -0
  94. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +1096 -0
  95. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +164 -0
  96. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +10663 -0
  97. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +886 -0
  98. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +194 -0
  99. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +44 -0
  100. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +247 -0
  101. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +3094 -0
  102. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +829 -0
  103. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +562 -0
  104. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +52 -0
  105. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +220 -0
  106. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +156 -0
  107. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +1316 -0
  108. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +22079 -0
  109. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +994 -0
  110. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +68 -0
  111. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +28 -0
  112. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +12 -0
  113. data/data/standards/manage_OpenStudio_Standards.rb +87 -37
  114. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1-ALL-comstockspace_types.csv +236 -0
  115. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +622 -0
  116. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1space_types.csv +195 -0
  117. data/data/standards/openstudio_standards_duplicates_log.csv +28 -0
  118. data/data/standards/test_performance_expected_dd_results.csv +1934 -1134
  119. data/lib/openstudio-standards.rb +68 -17
  120. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +28 -0
  121. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +0 -1
  122. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +28 -0
  123. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +53 -2
  124. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +29 -0
  125. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +157 -2
  126. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +29 -0
  127. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
  128. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +32 -0
  129. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +33 -0
  130. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +32 -0
  131. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +25 -0
  132. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +366 -0
  133. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +144 -0
  134. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +11 -0
  135. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
  136. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +32 -0
  137. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +33 -0
  138. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +32 -0
  139. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +25 -0
  140. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +367 -0
  141. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +144 -0
  142. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +11 -0
  143. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +0 -1
  144. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +0 -1
  145. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
  146. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
  147. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
  148. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
  149. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +3 -3
  150. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +74 -0
  151. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +46 -30
  152. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +23 -8
  153. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +26 -15
  154. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +8 -11
  155. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +54 -60
  156. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +56 -60
  157. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +38 -12
  158. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +218 -134
  159. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +6 -2
  160. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +230 -134
  161. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +60 -62
  162. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +25 -15
  163. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +34 -22
  164. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +31 -7
  165. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +43 -28
  166. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +48 -38
  167. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +9 -5
  168. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +575 -345
  169. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +13 -19
  170. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +13 -17
  171. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +9 -5
  172. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +79 -51
  173. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +60 -60
  174. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +2 -4
  175. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +133 -120
  176. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +124 -112
  177. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +138 -66
  178. data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +7275 -199
  179. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +35 -35
  180. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -2
  181. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -2
  182. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +3 -3
  183. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +1 -1
  184. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +2 -2
  185. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +2 -2
  186. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
  187. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +2 -2
  188. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +2 -2
  189. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
  190. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
  191. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +4 -3
  192. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +7 -8
  193. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +7 -8
  194. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +13 -14
  195. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +7 -5
  196. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +4 -1
  197. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +0 -1
  198. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +25 -14
  199. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +474 -89
  200. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +35 -33
  201. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +3 -0
  202. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +72 -0
  203. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +120 -120
  204. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +139 -151
  205. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +9 -3
  206. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +11 -5
  207. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +26 -14
  208. data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +270 -247
  209. data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
  210. data/lib/openstudio-standards/refs/references.rb +5 -2
  211. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +47 -30
  212. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -1
  213. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +0 -1
  214. data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +1 -0
  215. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +2 -4
  216. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +8 -10
  217. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -5
  218. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +0 -1
  219. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
  220. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +12 -9
  221. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -1
  222. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +3 -1
  223. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +0 -3
  224. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +4 -7
  225. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -3
  226. data/lib/openstudio-standards/standards/Standards.Construction.rb +124 -118
  227. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +0 -1
  228. data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +0 -1
  229. data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +0 -1
  230. data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +0 -1
  231. data/lib/openstudio-standards/standards/Standards.Fan.rb +0 -1
  232. data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -1
  233. data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -1
  234. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -4
  235. data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -1
  236. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +10 -3
  237. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -1
  238. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -1
  239. data/lib/openstudio-standards/standards/Standards.Model.rb +282 -253
  240. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -0
  241. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -9
  242. data/lib/openstudio-standards/standards/Standards.Pump.rb +0 -1
  243. data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -1
  244. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +0 -1
  245. data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +0 -1
  246. data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +0 -1
  247. data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +103 -121
  248. data/lib/openstudio-standards/standards/Standards.Space.rb +42 -35
  249. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +9 -17
  250. data/lib/openstudio-standards/standards/Standards.SubSurface.rb +25 -27
  251. data/lib/openstudio-standards/standards/Standards.Surface.rb +97 -52
  252. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +39 -21
  253. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +6 -7
  254. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +85 -7
  255. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +0 -1
  256. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +10 -2
  257. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model.rb +2 -2
  258. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +63 -99
  259. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +7 -7
  260. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +2420 -0
  261. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +32 -0
  262. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +9 -0
  263. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +70 -40
  264. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +6 -6
  265. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +6 -6
  266. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +1729 -1663
  267. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +5 -1
  268. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +63 -99
  269. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +7 -7
  270. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +1460 -0
  271. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +32 -0
  272. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +9 -0
  273. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +123 -39
  274. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +6 -6
  275. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +6 -6
  276. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +1728 -1641
  277. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +32 -15
  278. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +1 -1
  279. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +63 -99
  280. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +7 -7
  281. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +1460 -0
  282. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +64 -0
  283. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +52 -0
  284. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +9 -0
  285. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +123 -39
  286. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +6 -6
  287. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +6 -6
  288. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +1727 -1640
  289. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +37 -14
  290. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
  291. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +63 -99
  292. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +7 -7
  293. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +1 -1
  294. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +2 -2
  295. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +1460 -0
  296. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +64 -0
  297. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +104 -0
  298. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +9 -0
  299. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +125 -41
  300. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +6 -6
  301. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +6 -6
  302. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +1882 -1765
  303. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +4 -4
  304. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +1 -1
  305. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +456 -0
  306. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
  307. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +19 -0
  308. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerSingleSpeed.rb +5 -0
  309. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerTwoSpeed.rb +5 -0
  310. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +16 -0
  311. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +37 -0
  312. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +189 -0
  313. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +57 -0
  314. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +22 -0
  315. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +16 -0
  316. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.boilers.json +68 -0
  317. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.chillers.json +490 -0
  318. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_properties.json +21244 -0
  319. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_sets.json +2111 -0
  320. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.economizers.json +676 -0
  321. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.elevators.json +372 -0
  322. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +1096 -0
  323. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ext_ltg.json +169 -0
  324. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +532 -0
  325. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +164 -0
  326. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_rejection.json +49 -0
  327. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.motors.json +274 -0
  328. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.prototype_inputs.json +3094 -0
  329. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_cases.json +854 -0
  330. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_lnup.json +562 -0
  331. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_compressors.json +58 -0
  332. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_condenser.json +238 -0
  333. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_system.json +156 -0
  334. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_walkins.json +1316 -0
  335. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +23042 -0
  336. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +648 -0
  337. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +72 -0
  338. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps.json +31 -0
  339. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps_heating.json +13 -0
  340. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +456 -0
  341. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
  342. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +19 -0
  343. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerSingleSpeed.rb +5 -0
  344. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerTwoSpeed.rb +5 -0
  345. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +16 -0
  346. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +37 -0
  347. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +189 -0
  348. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +57 -0
  349. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +22 -0
  350. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +16 -0
  351. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +68 -0
  352. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.chillers.json +490 -0
  353. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_properties.json +21244 -0
  354. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_sets.json +2111 -0
  355. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.economizers.json +676 -0
  356. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.elevators.json +372 -0
  357. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +1096 -0
  358. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ext_ltg.json +169 -0
  359. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +664 -0
  360. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +204 -0
  361. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_rejection.json +49 -0
  362. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.motors.json +274 -0
  363. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.prototype_inputs.json +3094 -0
  364. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_cases.json +854 -0
  365. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_lnup.json +562 -0
  366. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +58 -0
  367. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_condenser.json +238 -0
  368. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_system.json +156 -0
  369. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_walkins.json +1316 -0
  370. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +23067 -0
  371. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +671 -0
  372. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +72 -0
  373. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps.json +31 -0
  374. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps_heating.json +13 -0
  375. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +1614 -284
  376. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.fans.json +1 -1
  377. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.materials.json +4860 -300
  378. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +1743 -161
  379. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +63 -99
  380. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +11 -11
  381. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.heat_rejection.json +9 -0
  382. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +50 -29
  383. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.ref_lnup.json +6 -6
  384. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.refrigeration_system.json +6 -6
  385. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +1334 -1334
  386. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +4 -4
  387. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +63 -99
  388. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ext_ltg.json +10 -10
  389. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.heat_rejection.json +9 -0
  390. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +49 -28
  391. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.ref_lnup.json +6 -6
  392. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.refrigeration_system.json +6 -6
  393. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +1322 -1322
  394. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +4 -4
  395. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_rejection.json +9 -0
  396. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.prototype_inputs.json +14 -7
  397. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.spc_typ.json +450 -450
  398. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +0 -1
  399. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +4 -4
  400. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
  401. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +1 -1
  402. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json +9 -0
  403. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.prototype_inputs.json +14 -7
  404. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json +332 -332
  405. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json +2 -2
  406. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +3 -6
  407. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +4 -4
  408. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
  409. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +1 -1
  410. data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -3
  411. data/lib/openstudio-standards/standards/cbes/cbes.rb +1 -1
  412. data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +8 -13
  413. data/lib/openstudio-standards/standards/deer/deer.Model.rb +2 -2
  414. data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +2 -0
  415. data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
  416. data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +0 -1
  417. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +0 -1
  418. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +0 -1
  419. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +0 -1
  420. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +0 -1
  421. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +1 -1
  422. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
  423. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +0 -1
  424. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +1 -1
  425. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
  426. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +0 -1
  427. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +1 -1
  428. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
  429. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +0 -1
  430. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +1 -1
  431. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
  432. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +0 -1
  433. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +1 -1
  434. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
  435. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +0 -1
  436. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +1 -1
  437. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
  438. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +0 -1
  439. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +1 -1
  440. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
  441. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +0 -1
  442. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +1 -1
  443. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
  444. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +0 -1
  445. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +1 -1
  446. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
  447. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +0 -1
  448. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +1 -1
  449. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
  450. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +0 -1
  451. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +1 -1
  452. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
  453. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +0 -1
  454. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +1 -1
  455. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
  456. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +0 -1
  457. data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +0 -1
  458. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +28 -7
  459. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +16 -2
  460. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +15 -0
  461. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +14 -0
  462. data/lib/openstudio-standards/standards/necb/ECMS/data/erv.json +11 -7
  463. data/lib/openstudio-standards/standards/necb/ECMS/data/pv.json +112 -0
  464. data/lib/openstudio-standards/standards/necb/ECMS/data/unitary_acs.json +50 -0
  465. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +21 -8
  466. data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +17 -6
  467. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +142 -6
  468. data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +189 -0
  469. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +104 -0
  470. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +19 -13
  471. data/lib/openstudio-standards/standards/necb/NECB2011/data/erv.json +1 -1
  472. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +39278 -0
  473. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +17 -1
  474. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +15 -0
  475. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +14 -2
  476. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +13 -0
  477. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +12 -0
  478. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +154 -12
  479. data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +21 -3
  480. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +187 -21
  481. data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +74 -0
  482. data/lib/openstudio-standards/standards/necb/NECB2011/pv_ground.md +44 -0
  483. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +2 -2
  484. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/qaqc_resources/neb_end_use_prices.csv +39 -84
  485. data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +0 -1
  486. data/lib/openstudio-standards/standards/standard.rb +6 -5
  487. data/lib/openstudio-standards/utilities/Add_template_field_to_json.rb +3 -3
  488. data/lib/openstudio-standards/utilities/convert_surfaces_to_adiabatic_necb_8426.rb +54 -54
  489. data/lib/openstudio-standards/utilities/generate_prototype_database.rb +2 -2
  490. data/lib/openstudio-standards/utilities/generate_space_types.rb +3 -3
  491. data/lib/openstudio-standards/utilities/logging.rb +7 -7
  492. data/lib/openstudio-standards/utilities/necb_to_epw_map.rb +14 -14
  493. data/lib/openstudio-standards/utilities/os_sim_extract.rb +25 -25
  494. data/lib/openstudio-standards/utilities/rename_surfaces.rb +10 -13
  495. data/lib/openstudio-standards/utilities/round_surf_coords.rb +18 -20
  496. data/lib/openstudio-standards/utilities/sched_create.rb +39 -41
  497. data/lib/openstudio-standards/utilities/set_mult_to_adiabatic.rb +31 -31
  498. data/lib/openstudio-standards/utilities/simulation.rb +13 -21
  499. data/lib/openstudio-standards/utilities/speacetype_map_converter.rb +10 -11
  500. data/lib/openstudio-standards/utilities/sqlfile.rb +6 -8
  501. data/lib/openstudio-standards/utilities/template_measure/measure.rb +108 -0
  502. data/lib/openstudio-standards/utilities/template_measure/measure.xml +162 -0
  503. data/lib/openstudio-standards/utilities/template_measure/resources/BTAPMeasureHelper.rb +448 -0
  504. data/lib/openstudio-standards/utilities/template_measure/tests/test.rb +160 -0
  505. data/lib/openstudio-standards/utilities/weatherData1_xlsx_to_json.rb +23 -26
  506. data/lib/openstudio-standards/version.rb +1 -1
  507. data/lib/openstudio-standards/weather/Weather.Model.rb +112 -87
  508. data/lib/openstudio-standards/weather/Weather.stat_file.rb +17 -17
  509. metadata +216 -2
@@ -1,4 +1,3 @@
1
-
2
1
  # Custom changes for the MediumOffice prototype.
3
2
  # These are changes that are inconsistent with other prototype
4
3
  # building types.
@@ -39,8 +38,8 @@ module MediumOfficeDetailed
39
38
  infiltration_per_zone_entrydoor = 0
40
39
  if template == '90.1-2004'
41
40
  infiltration_per_zone_entrydoor = 1.04300287
42
- infiltration_entrydoor.setSchedule(model_add_schedule(model,'OfficeMedium INFIL_Door_Opening_SCH'))
43
- elsif template == '90.1-2007' || template == '90.1-2010'|| template == '90.1-2013'
41
+ infiltration_entrydoor.setSchedule(model_add_schedule(model, 'OfficeMedium INFIL_Door_Opening_SCH'))
42
+ elsif template == '90.1-2007' || template == '90.1-2010' || template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019'
44
43
  case climate_zone
45
44
  when 'ASHRAE 169-2006-1A', 'ASHRAE 169-2006-2A', 'ASHRAE 169-2006-1B', 'ASHRAE 169-2006-2B'
46
45
  infiltration_per_zone_entrydoor = 1.04300287
@@ -53,68 +52,65 @@ module MediumOfficeDetailed
53
52
  infiltration_entrydoor.setDesignFlowRate(infiltration_per_zone_entrydoor)
54
53
  infiltration_entrydoor.setSpace(entry_space)
55
54
  end
56
- end
55
+ end
57
56
 
58
- # def model_custom_daylighting_tweaks(building_type, climate_zone, prototype_input, model)
59
- # OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Adjusting daylight sensor positions and fractions')
60
- #
61
- # adjustments = [
62
- # { 'stds_spc_type' => 'WholeBuilding - Md Office',
63
- # 'sensor_1_frac' => 0.3835,
64
- # 'sensor_2_frac' => 0.1395,
65
- # }
66
- # ]
67
- #
68
- # Adjust daylight sensors in each space
69
- # model.getSpaces.each do |space|
70
- # next if space.thermalZone.empty?
71
- # zone = space.thermalZone.get
72
- # next if space.spaceType.empty?
73
- # spc_type = space.spaceType.get
74
- # next if spc_type.standardsSpaceType.empty?
75
- # stds_spc_type = spc_type.standardsSpaceType.get
76
- # adjustments.each do |adj|
77
- # next unless adj['stds_spc_type'] == stds_spc_type
78
- # # Adjust the primary sensor
79
- # if adj['sensor_1_frac'] && zone.primaryDaylightingControl.is_initialized
80
- # OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting primary daylight sensor to control #{adj['sensor_1_frac']} of the lighting.")
81
- # zone.setFractionofZoneControlledbyPrimaryDaylightingControl(adj['sensor_1_frac'])
82
- # pri_ctrl = zone.primaryDaylightingControl.get
83
- # if adj['sensor_1_xyz']
84
- # x = adj['sensor_1_xyz'][0]
85
- # y = adj['sensor_1_xyz'][1]
86
- # z = adj['sensor_1_xyz'][2]
87
- # OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting primary daylight sensor position to [#{x}, #{y}, #{z}].")
88
- # pri_ctrl.setPositionXCoordinate(x)
89
- # pri_ctrl.setPositionYCoordinate(y)
90
- # pri_ctrl.setPositionZCoordinate(z)
91
- # end
92
- # end
93
- # Adjust the secondary sensor
94
- # if adj['sensor_2_frac'] && zone.secondaryDaylightingControl.is_initialized
95
- # OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting secondary daylight sensor to control #{adj['sensor_2_frac']} of the lighting.")
96
- # zone.setFractionofZoneControlledbySecondaryDaylightingControl(adj['sensor_2_frac'])
97
- # sec_ctrl = zone.secondaryDaylightingControl.get
98
- # if adj['sensor_2_xyz']
99
- # x = adj['sensor_2_xyz'][0]
100
- # y = adj['sensor_2_xyz'][1]
101
- # z = adj['sensor_2_xyz'][2]
102
- # OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting secondary daylight sensor position to [#{x}, #{y}, #{z}].")
103
- # sec_ctrl.setPositionXCoordinate(x)
104
- # sec_ctrl.setPositionYCoordinate(y)
105
- # sec_ctrl.setPositionZCoordinate(z)
106
- # end
107
- # end
108
- #
109
- # end
110
- # end
111
- #
112
- # return true
113
- # end
57
+ # def model_custom_daylighting_tweaks(building_type, climate_zone, prototype_input, model)
58
+ # OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Adjusting daylight sensor positions and fractions')
59
+ #
60
+ # adjustments = [
61
+ # { 'stds_spc_type' => 'WholeBuilding - Md Office',
62
+ # 'sensor_1_frac' => 0.3835,
63
+ # 'sensor_2_frac' => 0.1395 }
64
+ # ]
65
+ #
66
+ # # Adjust daylight sensors in each space
67
+ # model.getSpaces.each do |space|
68
+ # next if space.thermalZone.empty?
69
+ # zone = space.thermalZone.get
70
+ # next if space.spaceType.empty?
71
+ # spc_type = space.spaceType.get
72
+ # next if spc_type.standardsSpaceType.empty?
73
+ # stds_spc_type = spc_type.standardsSpaceType.get
74
+ # adjustments.each do |adj|
75
+ # next unless adj['stds_spc_type'] == stds_spc_type
76
+ # # Adjust the primary sensor
77
+ # if adj['sensor_1_frac'] && zone.primaryDaylightingControl.is_initialized
78
+ # OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting primary daylight sensor to control #{adj['sensor_1_frac']} of the lighting.")
79
+ # zone.setFractionofZoneControlledbyPrimaryDaylightingControl(adj['sensor_1_frac'])
80
+ # pri_ctrl = zone.primaryDaylightingControl.get
81
+ # if adj['sensor_1_xyz']
82
+ # x = adj['sensor_1_xyz'][0]
83
+ # y = adj['sensor_1_xyz'][1]
84
+ # z = adj['sensor_1_xyz'][2]
85
+ # OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting primary daylight sensor position to [#{x}, #{y}, #{z}].")
86
+ # pri_ctrl.setPositionXCoordinate(x)
87
+ # pri_ctrl.setPositionYCoordinate(y)
88
+ # pri_ctrl.setPositionZCoordinate(z)
89
+ # end
90
+ # end
91
+ # # Adjust the secondary sensor
92
+ # if adj['sensor_2_frac'] && zone.secondaryDaylightingControl.is_initialized
93
+ # OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting secondary daylight sensor to control #{adj['sensor_2_frac']} of the lighting.")
94
+ # zone.setFractionofZoneControlledbySecondaryDaylightingControl(adj['sensor_2_frac'])
95
+ # sec_ctrl = zone.secondaryDaylightingControl.get
96
+ # if adj['sensor_2_xyz']
97
+ # x = adj['sensor_2_xyz'][0]
98
+ # y = adj['sensor_2_xyz'][1]
99
+ # z = adj['sensor_2_xyz'][2]
100
+ # OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting secondary daylight sensor position to [#{x}, #{y}, #{z}].")
101
+ # sec_ctrl.setPositionXCoordinate(x)
102
+ # sec_ctrl.setPositionYCoordinate(y)
103
+ # sec_ctrl.setPositionZCoordinate(z)
104
+ # end
105
+ # end
106
+ # end
107
+ # end
108
+ # return true
109
+ # end
114
110
 
115
111
  def update_waterheater_loss_coefficient(model)
116
112
  case template
117
- when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', 'NECB2011'
113
+ when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019', 'NECB2011'
118
114
  model.getWaterHeaterMixeds.sort.each do |water_heater|
119
115
  water_heater.setOffCycleLossCoefficienttoAmbientTemperature(7.561562668)
120
116
  water_heater.setOnCycleLossCoefficienttoAmbientTemperature(7.561562668)
@@ -129,12 +125,14 @@ module MediumOfficeDetailed
129
125
  end
130
126
 
131
127
  def model_custom_geometry_tweaks(building_type, climate_zone, prototype_input, model)
128
+ # Set original building North axis
129
+ model_set_building_north_axis(model, 0.0)
132
130
 
133
131
  return true
134
132
  end
135
133
 
136
134
  def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
137
- min_damper_position = template == '90.1-2010' || template == '90.1-2013' ? 0.2 : 0.3
135
+ min_damper_position = template == '90.1-2010' || template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019' ? 0.2 : 0.3
138
136
 
139
137
  # Set the minimum flow fraction
140
138
  air_terminal_single_duct_vav_reheat.setConstantMinimumAirFlowFraction(min_damper_position)
@@ -1,4 +1,3 @@
1
-
2
1
  # Custom changes for the MidriseApartment prototype.
3
2
  # These are changes that are inconsistent with other prototype
4
3
  # building types.
@@ -26,9 +25,11 @@ module MidriseApartment
26
25
  case template
27
26
  when '90.1-2004', '90.1-2007', '90.1-2010'
28
27
  case climate_zone
29
- when 'ASHRAE 169-2006-1B',
28
+ when 'ASHRAE 169-2006-0B',
29
+ 'ASHRAE 169-2006-1B',
30
30
  'ASHRAE 169-2006-2B',
31
31
  'ASHRAE 169-2006-3B',
32
+ 'ASHRAE 169-2013-0B',
32
33
  'ASHRAE 169-2013-1B',
33
34
  'ASHRAE 169-2013-2B',
34
35
  'ASHRAE 169-2013-3B'
@@ -45,7 +46,7 @@ module MidriseApartment
45
46
  elec_equip_def1.setName('Ground Corridor Electric Equipment Definition1')
46
47
  elec_equip_def2.setName('Ground Corridor Electric Equipment Definition2')
47
48
  case template
48
- when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
49
+ when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
49
50
  elec_equip_def1.setFractionLatent(0)
50
51
  elec_equip_def1.setFractionRadiant(0)
51
52
  elec_equip_def1.setFractionLost(0.95)
@@ -53,7 +54,7 @@ module MidriseApartment
53
54
  elec_equip_def2.setFractionRadiant(0)
54
55
  elec_equip_def2.setFractionLost(0.95)
55
56
  elec_equip_def1.setDesignLevel(16_055)
56
- if template == '90.1-2013'
57
+ if template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019'
57
58
  elec_equip_def2.setDesignLevel(63)
58
59
  elsif template == '90.1-2010'
59
60
  elec_equip_def2.setDesignLevel(105.9)
@@ -71,7 +72,7 @@ module MidriseApartment
71
72
  case template
72
73
  when '90.1-2004', '90.1-2007'
73
74
  elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_24_7'))
74
- when '90.1-2010', '90.1-2013'
75
+ when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
75
76
  elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_ADD_DF'))
76
77
  end
77
78
  when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004'
@@ -92,7 +93,7 @@ module MidriseApartment
92
93
  case template
93
94
  when 'DOE Ref 1980-2004', 'DOE Ref Pre-1980'
94
95
  # no door infiltration in these two vintages
95
- when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
96
+ when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
96
97
  g_corridor = model.getSpaceByName('G Corridor').get
97
98
  infiltration_g_corridor_door = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
98
99
  infiltration_g_corridor_door.setName('G Corridor door Infiltration')
@@ -103,11 +104,15 @@ module MidriseApartment
103
104
  infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentMidRise INFIL_Door_Opening_SCH_2004_2007'))
104
105
  when '90.1-2007'
105
106
  case climate_zone
106
- when 'ASHRAE 169-2006-1A',
107
+ when 'ASHRAE 169-2006-0A',
108
+ 'ASHRAE 169-2006-1A',
109
+ 'ASHRAE 169-2006-0B',
107
110
  'ASHRAE 169-2006-1B',
108
111
  'ASHRAE 169-2006-2A',
109
112
  'ASHRAE 169-2006-2B',
113
+ 'ASHRAE 169-2013-0A',
110
114
  'ASHRAE 169-2013-1A',
115
+ 'ASHRAE 169-2013-0B',
111
116
  'ASHRAE 169-2013-1B',
112
117
  'ASHRAE 169-2013-2A',
113
118
  'ASHRAE 169-2013-2B'
@@ -116,13 +121,17 @@ module MidriseApartment
116
121
  infiltration_g_corridor_door.setDesignFlowRate(0.327531218)
117
122
  end
118
123
  infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentMidRise INFIL_Door_Opening_SCH_2004_2007'))
119
- when '90.1-2010', '90.1-2013'
124
+ when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
120
125
  case climate_zone
121
- when 'ASHRAE 169-2006-1A',
126
+ when 'ASHRAE 169-2006-0A',
127
+ 'ASHRAE 169-2006-1A',
128
+ 'ASHRAE 169-2006-0B',
122
129
  'ASHRAE 169-2006-1B',
123
130
  'ASHRAE 169-2006-2A',
124
131
  'ASHRAE 169-2006-2B',
132
+ 'ASHRAE 169-2013-0A',
125
133
  'ASHRAE 169-2013-1A',
134
+ 'ASHRAE 169-2013-0B',
126
135
  'ASHRAE 169-2013-1B',
127
136
  'ASHRAE 169-2013-2A',
128
137
  'ASHRAE 169-2013-2B'
@@ -133,20 +142,21 @@ module MidriseApartment
133
142
  infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentMidRise INFIL_Door_Opening_SCH_2010_2013'))
134
143
  end
135
144
 
136
- # Door infiltration in model not impacted by wind or temperature
137
- infiltration_g_corridor_door.setConstantTermCoefficient(1.0)
138
- infiltration_g_corridor_door.setTemperatureTermCoefficient(0.0)
139
- infiltration_g_corridor_door.setVelocityTermCoefficient(0.0)
140
- infiltration_g_corridor_door.setVelocitySquaredTermCoefficient(0.0)
145
+ # Door infiltration in model not impacted by wind or temperature
146
+ infiltration_g_corridor_door.setConstantTermCoefficient(1.0)
147
+ infiltration_g_corridor_door.setTemperatureTermCoefficient(0.0)
148
+ infiltration_g_corridor_door.setVelocityTermCoefficient(0.0)
149
+ infiltration_g_corridor_door.setVelocitySquaredTermCoefficient(0.0)
141
150
  end
142
151
  end
143
152
 
144
153
  def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input)
145
-
146
154
  return true
147
155
  end
148
156
 
149
157
  def model_custom_geometry_tweaks(building_type, climate_zone, prototype_input, model)
158
+ # Set original building North axis
159
+ model_set_building_north_axis(model, 0.0)
150
160
 
151
161
  return true
152
162
  end
@@ -1,4 +1,3 @@
1
-
2
1
  # Custom changes for the Outpatient prototype.
3
2
  # These are changes that are inconsistent with other prototype
4
3
  # building types.
@@ -86,7 +85,7 @@ module Outpatient
86
85
  elec_equip.setName('Elevator Pump Room Elevator Equipment')
87
86
  elec_equip.setSpace(elevator_pump_room)
88
87
  case template
89
- when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
88
+ when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
90
89
  elec_equip.setSchedule(model_add_schedule(model, 'OutPatientHealthCare BLDG_ELEVATORS'))
91
90
 
92
91
  # add elevator fan and lights for 90.1 prototypes
@@ -101,7 +100,7 @@ module Outpatient
101
100
  elec_equip_def2.setDesignLevel(485.7)
102
101
  when '90.1-2010'
103
102
  elec_equip_def2.setDesignLevel(317.7)
104
- when '90.1-2013'
103
+ when '90.1-2013', '90.1-2016', '90.1-2019'
105
104
  elec_equip_def2.setDesignLevel(188)
106
105
  end
107
106
 
@@ -112,12 +111,12 @@ module Outpatient
112
111
  case template # light fan schedule for outpatient already exist in the schedule data sheet.
113
112
  when '90.1-2004', '90.1-2007'
114
113
  elec_equip2.setSchedule(model_add_schedule(model, 'OutPatientHealthCare ELEV_LIGHT_FAN_SCH_24_7'))
115
- when '90.1-2010', '90.1-2013'
114
+ when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
116
115
  elec_equip2.setSchedule(model_add_schedule(model, 'OutPatientHealthCare ELEV_LIGHT_FAN_SCH_ADD_DF'))
117
116
  end
118
117
 
119
118
  when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004'
120
- elec_equip.setSchedule(model_add_schedule(model, 'OutPatientHealthCare BLDG_ELEVATORS_Pre2004'))
119
+ elec_equip.setSchedule(model_add_schedule(model, 'OutPatientHealthCare BLDG_ELEVATORS_Pre2004'))
121
120
  end
122
121
  return true
123
122
  end
@@ -130,9 +129,11 @@ module Outpatient
130
129
  case template
131
130
  when '90.1-2004', '90.1-2007', '90.1-2010'
132
131
  case climate_zone
133
- when 'ASHRAE 169-2006-1B',
132
+ when 'ASHRAE 169-2006-0B',
133
+ 'ASHRAE 169-2006-1B',
134
134
  'ASHRAE 169-2006-2B',
135
135
  'ASHRAE 169-2006-3B',
136
+ 'ASHRAE 169-2013-0B',
136
137
  'ASHRAE 169-2013-1B',
137
138
  'ASHRAE 169-2013-2B',
138
139
  'ASHRAE 169-2013-3B'
@@ -193,11 +194,13 @@ module Outpatient
193
194
  when '90.1-2004'
194
195
  infiltration_rate_vestibule_door = 1.186002811
195
196
  infiltration_vestibule_door.setSchedule(model_add_schedule(model, 'OutPatientHealthCare INFIL_Door_Opening_SCH_0.144'))
196
- when '90.1-2007', '90.1-2010', '90.1-2013'
197
+ when '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
197
198
  case climate_zone
198
- when 'ASHRAE 169-2006-1A',
199
+ when 'ASHRAE 169-2006-0A',
200
+ 'ASHRAE 169-2006-1A',
199
201
  'ASHRAE 169-2006-2A',
200
202
  'ASHRAE 169-2006-2B',
203
+ 'ASHRAE 169-2013-0A',
201
204
  'ASHRAE 169-2013-1A',
202
205
  'ASHRAE 169-2013-2A',
203
206
  'ASHRAE 169-2013-2B'
@@ -239,7 +242,7 @@ module Outpatient
239
242
  humidifier.addToNode(heating_coil_outlet_node)
240
243
  humidity_spm = OpenStudio::Model::SetpointManagerSingleZoneHumidityMinimum.new(model)
241
244
  case template
242
- when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
245
+ when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
243
246
  create_coil_heating_electric(model,
244
247
  air_loop_node: supply_outlet_node,
245
248
  name: 'AHU1 extra Electric Htg Coil')
@@ -267,9 +270,9 @@ module Outpatient
267
270
  controller_mv.setAvailabilitySchedule(model.alwaysOffDiscreteSchedule)
268
271
  # add minimum fraction of outdoor air schedule to AHU1
269
272
  controller_oa.setMinimumFractionofOutdoorAirSchedule(model_add_schedule(model, 'OutPatientHealthCare AHU-1_OAminOAFracSchedule'))
270
- # for AHU2, at vintages '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', the minimum OA schedule is not the same as
273
+ # for AHU2, at vintages '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019' the minimum OA schedule is not the same as
271
274
  # airloop availability schedule, but separately assigned.
272
- elsif template == '90.1-2004' || template == '90.1-2007' || template == '90.1-2010' || template == '90.1-2013'
275
+ elsif template == '90.1-2004' || template == '90.1-2007' || template == '90.1-2010' || template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019'
273
276
  controller_oa.setMinimumOutdoorAirSchedule(model_add_schedule(model, 'OutPatientHealthCare BLDG_OA_SCH'))
274
277
  # add minimum fraction of outdoor air schedule to AHU2
275
278
  controller_oa.setMinimumFractionofOutdoorAirSchedule(model_add_schedule(model, 'OutPatientHealthCare BLDG_OA_FRAC_SCH'))
@@ -323,7 +326,7 @@ module Outpatient
323
326
  # Based on AIA 2001 ventilation requirements
324
327
  # See Section 5.2.2.16 in Thornton et al. 2010
325
328
  # https://www.energycodes.gov/sites/default/files/documents/BECP_Energy_Cost_Savings_STD2010_May2011_v00.pdf
326
- when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
329
+ when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
327
330
  zone_name = zone.name.to_s.upcase.gsub(' ZN', '').strip
328
331
  if init_mdp.key? zone_name
329
332
  air_terminal.setConstantMinimumAirFlowFraction(init_mdp[zone_name])
@@ -334,18 +337,18 @@ module Outpatient
334
337
  end
335
338
  end
336
339
 
337
- # For operating room 1&2 in 2010 and 2013, VAV minimum air flow is set by schedule
340
+ # For operating room 1&2 in 2010, 2013, 2016, and 2019 VAV minimum air flow is set by schedule
338
341
  # This is NOT called in model_custom_hvac_tweaks,
339
342
  # instead it is called by model_reset_or_room_vav_minimum_damper AFTER the sizing run,
340
343
  # so that the system is sized at a constant airflow fraction of 1.0,
341
344
  # not 0.3 as defaulted in the zone sizing object
342
345
  def model_reset_or_room_vav_minimum_damper(prototype_input, model)
343
346
  case template
344
- when '90.1-2010', '90.1-2013'
347
+ when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
345
348
  model.getAirTerminalSingleDuctVAVReheats.sort.each do |air_terminal|
346
349
  air_terminal_name = air_terminal.name.get
347
350
  if air_terminal_name.include?('Floor 1 Operating Room 1') || air_terminal_name.include?('Floor 1 Operating Room 2')
348
- air_terminal.setZoneMinimumAirFlowMethod('Scheduled')
351
+ air_terminal.setZoneMinimumAirFlowInputMethod('Scheduled')
349
352
  air_terminal.setMinimumAirFlowFractionSchedule(model_add_schedule(model, 'OutPatientHealthCare OR_MinSA_Sched'))
350
353
  end
351
354
  end
@@ -362,7 +365,7 @@ module Outpatient
362
365
 
363
366
  def model_update_exhaust_fan_efficiency(model)
364
367
  case template
365
- when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
368
+ when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
366
369
  model.getFanZoneExhausts.sort.each do |exhaust_fan|
367
370
  fan_name = exhaust_fan.name.to_s
368
371
  if (fan_name.include? 'X-Ray') || (fan_name.include? 'MRI Room')
@@ -386,9 +389,9 @@ module Outpatient
386
389
  model.getSpaces.sort.each do |space|
387
390
  space_type_name = space.spaceType.get.standardsSpaceType.get
388
391
  search_criteria = {
389
- 'template' => template,
390
- 'building_type' => building_type,
391
- 'space_type' => space_type_name
392
+ 'template' => template,
393
+ 'building_type' => building_type,
394
+ 'space_type' => space_type_name
392
395
  }
393
396
  data = standards_lookup_table_first(table_name: 'space_types', search_criteria: search_criteria)
394
397
 
@@ -413,18 +416,19 @@ module Outpatient
413
416
  case template
414
417
  when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004'
415
418
  sizingzone.setCoolingMinimumAirFlow(minimum_airflow_per_zone)
416
- when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
419
+ when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
417
420
  sizingzone.setCoolingMinimumAirFlowperZoneFloorArea(minimum_airflow_per_zone_floor_area)
418
421
  end
419
422
  end
420
423
  end
421
424
 
422
425
  def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input)
423
-
424
426
  return true
425
427
  end
426
428
 
427
429
  def model_custom_geometry_tweaks(building_type, climate_zone, prototype_input, model)
430
+ # Set original building North axis
431
+ model_set_building_north_axis(model, 0.0)
428
432
 
429
433
  return true
430
434
  end
@@ -457,7 +461,7 @@ module Outpatient
457
461
  'FLOOR 3 STORAGE 1' => 1.0,
458
462
  'FLOOR 3 TREATMENT' => 1.0
459
463
  }
460
- elsif template == '90.1-2010' || template == '90.1-2013'
464
+ elsif template == '90.1-2010' || template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019'
461
465
  min_damper_position = 0.2
462
466
  init_mdp = {
463
467
  'FLOOR 2 CONFERENCE TOILET' => 1.0,
@@ -498,4 +502,12 @@ module Outpatient
498
502
 
499
503
  return true
500
504
  end
505
+
506
+ # Type of SAT reset for this building type
507
+ #
508
+ # @param air_loop_hvac [OpenStudio::model::AirLoopHVAC] Airloop
509
+ # @return [String] Returns type of SAT reset
510
+ def air_loop_hvac_supply_air_temperature_reset_type(air_loop_hvac)
511
+ return 'oa'
512
+ end
501
513
  end
@@ -1,18 +1,21 @@
1
-
2
1
  # Custom changes for the PrimarySchool prototype.
3
2
  # These are changes that are inconsistent with other prototype
4
3
  # building types.
5
4
  module PrimarySchool
6
5
  def model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model)
7
- OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific adjustments')
6
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific HVAC adjustments')
8
7
 
9
8
  # add transformer
10
- transformer_efficiency = nil
9
+ # efficiency based on a 113 kVA transformer
11
10
  case template
12
11
  when '90.1-2004', '90.1-2007'
13
12
  transformer_efficiency = 0.969
14
13
  when '90.1-2010', '90.1-2013'
15
14
  transformer_efficiency = 0.982
15
+ when '90.1-2016', '90.1-2019'
16
+ transformer_efficiency = 0.987
17
+ else
18
+ transformer_efficiency = nil
16
19
  end
17
20
  return true unless !transformer_efficiency.nil?
18
21
 
@@ -37,14 +40,14 @@ module PrimarySchool
37
40
  elec_equip_def1.setName('Kitchen Electric Equipment Definition1')
38
41
  elec_equip_def2.setName('Kitchen Electric Equipment Definition2')
39
42
  case template
40
- when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
43
+ when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
41
44
  elec_equip_def1.setFractionLatent(0)
42
45
  elec_equip_def1.setFractionRadiant(0.25)
43
46
  elec_equip_def1.setFractionLost(0)
44
47
  elec_equip_def2.setFractionLatent(0)
45
48
  elec_equip_def2.setFractionRadiant(0.25)
46
49
  elec_equip_def2.setFractionLost(0)
47
- if template == '90.1-2013'
50
+ if template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019'
48
51
  elec_equip_def1.setDesignLevel(915)
49
52
  elec_equip_def2.setDesignLevel(570)
50
53
  else
@@ -67,7 +70,7 @@ module PrimarySchool
67
70
  model.getWaterHeaterMixeds.sort.each do |water_heater|
68
71
  if water_heater.name.to_s.include?('Booster')
69
72
  water_heater.resetAmbientTemperatureSchedule
70
- water_heater.setAmbientTemperatureIndicator('ThermalZone')
73
+ water_heater.setAmbientTemperatureIndicator('ThermalZone')
71
74
  water_heater.setAmbientTemperatureThermalZone(model.getThermalZoneByName('Kitchen_ZN_1_FLR_1 ZN').get)
72
75
  end
73
76
  end
@@ -80,16 +83,37 @@ module PrimarySchool
80
83
  end
81
84
 
82
85
  def model_custom_geometry_tweaks(building_type, climate_zone, prototype_input, model)
86
+ # Set original building North axis
87
+ model_set_building_north_axis(model, 0.0)
83
88
 
84
89
  return true
85
90
  end
86
91
 
87
92
  def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
88
- min_damper_position = template == '90.1-2010' || template == '90.1-2013' ? 0.2 : 0.3
93
+ min_damper_position = template == '90.1-2010' || template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019' ? 0.2 : 0.3
89
94
 
90
95
  # Set the minimum flow fraction
91
96
  air_terminal_single_duct_vav_reheat.setConstantMinimumAirFlowFraction(min_damper_position)
92
97
 
93
98
  return true
94
99
  end
100
+
101
+ # Type of SAT reset for this building type
102
+ #
103
+ # @param air_loop_hvac [OpenStudio::model::AirLoopHVAC] Airloop
104
+ # @return [String] Returns type of SAT reset
105
+ def air_loop_hvac_supply_air_temperature_reset_type(air_loop_hvac)
106
+ return 'oa'
107
+ end
108
+
109
+ # List transfer air target and source zones, and air flow (cfm)
110
+ #
111
+ # code_sections [90.1-2019_6.5.7.1], [90.1-2016_6.5.7.1]
112
+ # @return [Hash] target zones (key) and source zones (value) and air flow (value)
113
+ def model_transfer_air_target_and_source_zones(model)
114
+ model_transfer_air_target_and_source_zones_hash = {
115
+ 'Bath_ZN_1_FLR_1 ZN' => ['Library_Media_Center_ZN_1_FLR_1 ZN', 600.0]
116
+ }
117
+ return model_transfer_air_target_and_source_zones_hash
118
+ end
95
119
  end