ppk2-lib 0.1.0__py3-none-any.whl

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -0,0 +1,51 @@
1
+ """Per-sample current calibration.
2
+
3
+ ``current_micro_amps`` turns one raw ADC count into microamperes, given
4
+ the range, the per-device coefficients, and the present supply voltage.
5
+ It is stateless and computes the same formula as Nordic's ``getAdcResult``;
6
+ the spike filter that follows a range change lives in the stream
7
+ parser.
8
+
9
+ Regression-tested against a sample word from a real PPK2 with its
10
+ captured coefficients: ``0x015c0097`` gives ``5.302145379685201`` µA.
11
+ """
12
+
13
+ from ppk2.protocol.metadata import CalibrationCoefficients
14
+
15
+ # The firmware's ADC scaling: a 1.8 V reference over 2^14 * 10 (the
16
+ # 14-bit count, with *10 of internal headroom).
17
+ _ADC_MULT: float = 1.8 / 163_840.0
18
+
19
+
20
+ def current_micro_amps(
21
+ adc_14: int,
22
+ range_idx: int,
23
+ vdd_mv: int,
24
+ coeffs: CalibrationCoefficients,
25
+ ) -> float:
26
+ """Convert one raw ADC reading into microamperes.
27
+
28
+ Args:
29
+ adc_14: 14-bit ADC value, straight from ``RawSample.adc_14``
30
+ (the *4 rescale happens here).
31
+ range_idx: Range index, 0 to 4.
32
+ vdd_mv: Present supply voltage in millivolts (the last
33
+ ``REGULATOR_SET``). Needed in Ampere meter mode too.
34
+ coeffs: Per-device calibration from ``parse_metadata``.
35
+
36
+ Raises:
37
+ IndexError: If ``range_idx`` is above 4.
38
+ """
39
+ r = range_idx
40
+
41
+ # Measured voltage over the range's resistance: the current before correction, in amperes.
42
+ counts = float(adc_14) * 4.0 - coeffs.o[r]
43
+ raw_amps = counts * (_ADC_MULT / coeffs.r[r])
44
+
45
+ # The per-range correction: a quadratic in the raw current, plus a
46
+ # term that follows the supply voltage.
47
+ vdd_volts = float(vdd_mv) / 1000.0
48
+ amps = coeffs.ug[r] * (
49
+ raw_amps * (coeffs.gs[r] * raw_amps + coeffs.gi[r]) + coeffs.s[r] * vdd_volts + coeffs.i[r]
50
+ )
51
+ return amps * 1e6
@@ -0,0 +1,320 @@
1
+ r"""Per-device calibration metadata returned by ``GET_METADATA`` (0x19).
2
+
3
+ The response is about 1 kB of ASCII ``key: value\n`` lines ending with a
4
+ literal ``END``. It can arrive split across reads: accumulate until
5
+ ``END`` is in the buffer, then call ``parse_metadata``.
6
+
7
+ Regression-tested against ``tests/fixtures/metadata.raw``, a real
8
+ response captured from a PPK2.
9
+ """
10
+
11
+ from dataclasses import dataclass
12
+ from math import isfinite, isnan
13
+
14
+ # Five measurement ranges, fixed across the PPK2 line.
15
+ NUM_RANGES = 5
16
+
17
+ # One value per range; a fixed-length tuple, so pyright checks the count.
18
+ RangeArray = tuple[float, float, float, float, float]
19
+
20
+ # The response starts with this key; what precedes it is not metadata.
21
+ _FIRST_KEY = b"Calibrated"
22
+
23
+ # What Nordic's Power Profiler app assumes for a slot the device left
24
+ # blank (the firmware prints ``-nan`` for one): nominal resistances,
25
+ # unit gains, no offsets.
26
+ _BLANK_DEFAULTS: dict[str, RangeArray] = {
27
+ "R": (1031.64, 101.65, 10.15, 0.94, 0.043),
28
+ "GS": (1.0, 1.0, 1.0, 1.0, 1.0),
29
+ "GI": (1.0, 1.0, 1.0, 1.0, 1.0),
30
+ "O": (0.0, 0.0, 0.0, 0.0, 0.0),
31
+ "S": (0.0, 0.0, 0.0, 0.0, 0.0),
32
+ "I": (0.0, 0.0, 0.0, 0.0, 0.0),
33
+ "UG": (1.0, 1.0, 1.0, 1.0, 1.0),
34
+ }
35
+
36
+
37
+ @dataclass(frozen=True, slots=True)
38
+ class CalibrationCoefficients:
39
+ """Per-device calibration, plus the VDD and mode the firmware reported.
40
+
41
+ Every coefficient is mandatory: a defaulted calibration value would
42
+ corrupt every sample, so ``parse_metadata`` raises ``MissingField``
43
+ instead. ``VDD`` and ``mode`` describe the device's present state,
44
+ not its calibration, and some firmware revisions omit them: those
45
+ two get defaults.
46
+
47
+ Attributes:
48
+ calibrated: The ``Calibrated`` value as reported. Not
49
+ interpreted: a PPK2 that reports ``False`` still carries a
50
+ full set of coefficients, and they are used.
51
+ r: Per-range resistance (Ω, virtual).
52
+ gs: Per-range gain slope (quadratic term).
53
+ gi: Per-range gain intercept (linear term).
54
+ o: Per-range ADC offset (16-bit-equivalent counts).
55
+ s: Per-range VDD-dependent linear slope.
56
+ i: Per-range VDD-dependent linear intercept.
57
+ ug: Per-range user gain (default 1.0).
58
+ vdd_mv: Supply voltage in millivolts, 800 to 5,000: the last
59
+ ``REGULATOR_SET``. It survives host disconnects: a PPK2
60
+ left at 1,800 mV reports it on the next open. 3,300 when
61
+ the firmware omits it.
62
+ mode: Power mode, ``1`` Ampere meter or ``2`` Source meter;
63
+ anything else raises ``InvalidValue``. Ampere meter, the
64
+ passive mode, when the firmware omits it.
65
+ hw: The ``HW`` value as reported. Not interpreted.
66
+ ia: The ``IA`` value as reported. Not interpreted.
67
+ """
68
+
69
+ calibrated: bool
70
+ r: RangeArray
71
+ gs: RangeArray
72
+ gi: RangeArray
73
+ o: RangeArray
74
+ s: RangeArray
75
+ i: RangeArray
76
+ ug: RangeArray
77
+ vdd_mv: int
78
+ mode: int
79
+ hw: int
80
+ ia: int
81
+
82
+
83
+ class MetadataError(Exception):
84
+ """Base class for metadata-parse failures."""
85
+
86
+
87
+ class MissingEnd(MetadataError):
88
+ """Buffer did not contain the ``END`` terminator.
89
+
90
+ The caller's accumulating-read loop has a bug.
91
+ """
92
+
93
+
94
+ class MissingField(MetadataError):
95
+ """A required key was absent; ``field`` names it (e.g. ``R[3]``)."""
96
+
97
+ def __init__(self, field: str) -> None:
98
+ super().__init__(f"missing required metadata field: {field}")
99
+ self.field = field
100
+
101
+
102
+ class InvalidValue(MetadataError):
103
+ """A field's value could not be parsed; ``value`` is the raw text."""
104
+
105
+ def __init__(self, field: str, value: str) -> None:
106
+ super().__init__(f"invalid value for {field}: {value!r}")
107
+ self.field = field
108
+ self.value = value
109
+
110
+
111
+ def parse_metadata(buf: bytes) -> CalibrationCoefficients:
112
+ r"""Parse a full ``GET_METADATA`` response into calibration coefficients.
113
+
114
+ Tolerant of unknown keys, ``END`` with or without a newline, spaces
115
+ around the ``:``, missing ``VDD``/``mode`` (see
116
+ ``CalibrationCoefficients``), and bytes before the text: the end
117
+ of a stream that was not read out, up to 1 kB of samples, can come
118
+ glued in front of the response. The parse starts at the first key,
119
+ ``Calibrated``.
120
+
121
+ Strict on missing calibration fields and on malformed values. A
122
+ blank slot (``-nan``) takes the default Nordic's app uses for it.
123
+
124
+ Raises:
125
+ MissingEnd: If ``buf`` has no ``END`` terminator.
126
+ MissingField: If a calibration key is absent.
127
+ InvalidValue: If a present field's value cannot be parsed.
128
+ """
129
+ start = buf.find(_FIRST_KEY)
130
+ if start > 0:
131
+ buf = buf[start:]
132
+ text = buf.decode("utf-8", errors="replace")
133
+
134
+ partial = _Partial()
135
+ saw_end = False
136
+
137
+ for raw_line in text.split("\n"):
138
+ line = raw_line.strip()
139
+ if not line:
140
+ continue
141
+ if line == "END":
142
+ saw_end = True
143
+ break
144
+ kv = _split_kv(line)
145
+ if kv is None:
146
+ # Lines without `:` are silently skipped (forward-compat).
147
+ continue
148
+ key, value = kv
149
+ partial.assign(key, value)
150
+
151
+ if not saw_end:
152
+ raise MissingEnd("no END terminator in metadata buffer")
153
+
154
+ return partial.finish()
155
+
156
+
157
+ # ─── internals ─────────────────────────────────────────────────────────
158
+
159
+
160
+ def _split_kv(line: str) -> tuple[str, str] | None:
161
+ """Split a line on the first ``:``; return ``(key, value)`` trimmed."""
162
+ if ":" not in line:
163
+ return None
164
+ k, _, v = line.partition(":")
165
+ return k.strip(), v.strip()
166
+
167
+
168
+ _PER_RANGE_PREFIXES = ("R", "GS", "GI", "O", "S", "I", "UG")
169
+
170
+
171
+ def _split_keyed_index(key: str) -> tuple[str, int] | None:
172
+ """Split a per-range key into prefix + numeric suffix.
173
+
174
+ Examples: ``"R0" -> ("R", 0)``, ``"GS4" -> ("GS", 4)``, ``"HW" -> None``,
175
+ ``"Calibrated" -> None``.
176
+ """
177
+ # Walk back from the end while digits, then take the suffix.
178
+ suffix_start = len(key)
179
+ while suffix_start > 0 and key[suffix_start - 1].isdigit():
180
+ suffix_start -= 1
181
+ if suffix_start == 0 or suffix_start == len(key):
182
+ return None
183
+ prefix = key[:suffix_start]
184
+ try:
185
+ idx = int(key[suffix_start:])
186
+ except ValueError:
187
+ return None
188
+ return prefix, idx
189
+
190
+
191
+ class _Partial:
192
+ """Mutable accumulator: ``assign`` fills it, ``finish`` seals it."""
193
+
194
+ def __init__(self) -> None:
195
+ self.calibrated: bool | None = None
196
+ self.r: list[float | None] = [None] * NUM_RANGES
197
+ self.gs: list[float | None] = [None] * NUM_RANGES
198
+ self.gi: list[float | None] = [None] * NUM_RANGES
199
+ self.o: list[float | None] = [None] * NUM_RANGES
200
+ self.s: list[float | None] = [None] * NUM_RANGES
201
+ self.i: list[float | None] = [None] * NUM_RANGES
202
+ self.ug: list[float | None] = [None] * NUM_RANGES
203
+ self.vdd_mv: int | None = None
204
+ self.mode: int | None = None
205
+ self.hw: int | None = None
206
+ self.ia: int | None = None
207
+
208
+ def assign(self, key: str, value: str) -> None:
209
+ keyed = _split_keyed_index(key)
210
+ if keyed is not None:
211
+ prefix, idx = keyed
212
+ if prefix not in _PER_RANGE_PREFIXES:
213
+ # An unknown array: ignored.
214
+ return
215
+ if idx >= NUM_RANGES:
216
+ # A sixth range and beyond: ignored.
217
+ return
218
+ slot = self._slot_for(prefix)
219
+ try:
220
+ parsed = float(value)
221
+ except ValueError as exc:
222
+ raise InvalidValue(f"{prefix}[{idx}]", value) from exc
223
+ if isnan(parsed):
224
+ # A slot the device left blank: the app's default, as
225
+ # the app does. A NaN kept here would turn every sample
226
+ # of that range into NaN.
227
+ parsed = _BLANK_DEFAULTS[prefix][idx]
228
+ elif not isfinite(parsed):
229
+ raise InvalidValue(f"{prefix}[{idx}]", value)
230
+ slot[idx] = parsed
231
+ return
232
+
233
+ # Scalar keys. Names match the wire-format exactly (PPK2 firmware
234
+ # is case-sensitive: `VDD` upper, `mode` lower).
235
+ if key == "Calibrated":
236
+ if value == "0":
237
+ self.calibrated = False
238
+ elif value == "1":
239
+ self.calibrated = True
240
+ else:
241
+ raise InvalidValue("Calibrated", value)
242
+ elif key == "HW":
243
+ try:
244
+ self.hw = int(value)
245
+ except ValueError as exc:
246
+ raise InvalidValue("HW", value) from exc
247
+ elif key == "IA":
248
+ try:
249
+ self.ia = int(value)
250
+ except ValueError as exc:
251
+ raise InvalidValue("IA", value) from exc
252
+ elif key == "VDD":
253
+ try:
254
+ self.vdd_mv = int(value)
255
+ except ValueError as exc:
256
+ raise InvalidValue("VDD", value) from exc
257
+ elif key == "mode":
258
+ try:
259
+ parsed_mode = int(value)
260
+ except ValueError as exc:
261
+ raise InvalidValue("mode", value) from exc
262
+ if parsed_mode not in (1, 2):
263
+ raise InvalidValue("mode", value)
264
+ self.mode = parsed_mode
265
+ # Unknown scalar key (e.g. VERSION_OUT): forward-compat, drop.
266
+
267
+ def _slot_for(self, prefix: str) -> list[float | None]:
268
+ # Mapping kept explicit so pyright knows every branch returns
269
+ # a typed list (no Any fallback).
270
+ if prefix == "R":
271
+ return self.r
272
+ if prefix == "GS":
273
+ return self.gs
274
+ if prefix == "GI":
275
+ return self.gi
276
+ if prefix == "O":
277
+ return self.o
278
+ if prefix == "S":
279
+ return self.s
280
+ if prefix == "I":
281
+ return self.i
282
+ if prefix == "UG":
283
+ return self.ug
284
+ raise AssertionError(f"unreachable: caller already filtered prefix={prefix!r}")
285
+
286
+ def finish(self) -> CalibrationCoefficients:
287
+ if self.calibrated is None:
288
+ raise MissingField("Calibrated")
289
+ if self.hw is None:
290
+ raise MissingField("HW")
291
+ if self.ia is None:
292
+ raise MissingField("IA")
293
+ # VDD and mode are state, not calibration, and may be absent:
294
+ # then 3300 mV and Ampere meter mode.
295
+ return CalibrationCoefficients(
296
+ calibrated=self.calibrated,
297
+ r=_seal("R", self.r),
298
+ gs=_seal("GS", self.gs),
299
+ gi=_seal("GI", self.gi),
300
+ o=_seal("O", self.o),
301
+ s=_seal("S", self.s),
302
+ i=_seal("I", self.i),
303
+ ug=_seal("UG", self.ug),
304
+ vdd_mv=self.vdd_mv if self.vdd_mv is not None else 3300,
305
+ mode=self.mode if self.mode is not None else 1,
306
+ hw=self.hw,
307
+ ia=self.ia,
308
+ )
309
+
310
+
311
+ def _seal(prefix: str, arr: list[float | None]) -> RangeArray:
312
+ """Turn a filled 5-slot list into a ``RangeArray``; ``MissingField`` on a gap."""
313
+ out: list[float] = []
314
+ for idx, value in enumerate(arr):
315
+ if value is None:
316
+ raise MissingField(f"{prefix}[{idx}]")
317
+ out.append(value)
318
+ # Unpack into a fixed 5-tuple so pyright sees the exact RangeArray length.
319
+ a, b, c, d, e = out
320
+ return (a, b, c, d, e)
@@ -0,0 +1,110 @@
1
+ """Wire opcodes.
2
+
3
+ Each opcode is one byte sent to the PPK2. The values are those of
4
+ Nordic's Power Profiler app (``pc-nrfconnect-ppk`` v4.4.1,
5
+ ``src/constants.ts``).
6
+ """
7
+
8
+ from enum import IntEnum
9
+
10
+
11
+ class Opcode(IntEnum):
12
+ """Single-byte opcode; the enum value is the wire byte.
13
+
14
+ ``Opcode.AVERAGE_START == 0x06``. ``byte()`` says the same thing at
15
+ call sites.
16
+ """
17
+
18
+ TRIGGER_SET = 0x01
19
+ """Generic ON parameter byte. Rarely sent as an opcode of its own."""
20
+
21
+ AVG_NUM_SET = 0x02
22
+ """Decimation count. Nordic's source marks it as not handled by the
23
+ firmware, which ignores it."""
24
+
25
+ TRIGGER_WINDOW_SET = 0x03
26
+ """Triggered-capture window size (u16 LE)."""
27
+
28
+ TRIGGER_INTERVAL_SET = 0x04
29
+ """Triggered-capture interval (u16 LE). Nordic's source marks it as
30
+ not handled by the firmware."""
31
+
32
+ TRIGGER_SINGLE_SET = 0x05
33
+ """Single-shot trigger arm."""
34
+
35
+ AVERAGE_START = 0x06
36
+ """Start the stream: 100,000 samples per second, each a 4-byte
37
+ little-endian word, until ``AVERAGE_STOP``."""
38
+
39
+ AVERAGE_STOP = 0x07
40
+ """Stop the sample stream."""
41
+
42
+ RANGE_SET = 0x08
43
+ """Manual measurement-range override (u8, 0 to 4). Rarely used, the
44
+ firmware auto-ranges. Nordic's source marks it as not handled by
45
+ the firmware."""
46
+
47
+ LCD_SET = 0x09
48
+ """LCD backlight. The PPK2 has no LCD; Nordic's source marks it as
49
+ not handled by the firmware."""
50
+
51
+ DEVICE_RUNNING_SET = 0x0C
52
+ """Power to the DUT: payload ``0x01`` on, ``0x00`` off. The app's "Enable power output".
53
+
54
+ Applied about 1 ms after it is sent, with or without a stream. One
55
+ sent within 0.31 s of ``AVERAGE_START`` is held until then (the
56
+ protocol page, Known caveats).
57
+ """
58
+
59
+ REGULATOR_SET = 0x0D
60
+ """Supply voltage in Source meter mode: ``[0x0D, mV >> 8, mV & 0xff]``
61
+ (big-endian), 800 to 5,000 mV.
62
+
63
+ In Ampere meter mode the regulator is inactive, but the calibration
64
+ still uses the last value sent (see ``current_micro_amps``).
65
+ """
66
+
67
+ SWITCH_POINT_DOWN = 0x0E
68
+ """Auto-range hysteresis (downward)."""
69
+
70
+ SWITCH_POINT_UP = 0x0F
71
+ """Auto-range hysteresis (upward)."""
72
+
73
+ SET_POWER_MODE = 0x11
74
+ """Measurement mode: payload ``0x01`` Ampere meter, ``0x02`` Source meter.
75
+
76
+ Nordic also names this byte ``TriggerExtToggle``, an
77
+ external-trigger function that shares it; this library only uses it
78
+ to set the mode.
79
+ """
80
+
81
+ RES_USER_SET = 0x12
82
+ """User-supplied resistor calibration. No known host sends it."""
83
+
84
+ SPIKE_FILTERING_ON = 0x15
85
+ """Enable firmware-side spike filtering."""
86
+
87
+ SPIKE_FILTERING_OFF = 0x16
88
+ """Disable firmware-side spike filtering."""
89
+
90
+ GET_METADATA = 0x19
91
+ """Request the per-device calibration: about 1 kB of ASCII
92
+ ``key: value\\n`` lines ending with ``END``."""
93
+
94
+ RESET = 0x20
95
+ """Restart the firmware. The PPK2 leaves USB and comes back 200 to
96
+ 500 ms later."""
97
+
98
+ SET_USER_GAINS = 0x25
99
+ """User gain override, payload ``[u8 range, f32 gain]``. Current
100
+ firmware accepts and ignores it."""
101
+
102
+ def byte(self) -> int:
103
+ """Return the single byte sent on the wire for this opcode."""
104
+ return int(self)
105
+
106
+ # No @override: it lives in typing from 3.12 or in typing_extensions,
107
+ # and this layer is stdlib-only on 3.11.
108
+ def __repr__(self) -> str: # pyright: ignore[reportImplicitOverride]
109
+ """Show the value in hex: these are wire bytes."""
110
+ return f"<{self.__class__.__name__}.{self.name}: 0x{self.value:02X}>"
@@ -0,0 +1,61 @@
1
+ """Sample-frame bit extraction.
2
+
3
+ Each PPK2 sample is a 4-byte little-endian word::
4
+
5
+ bits 0-13 ADC (14-bit raw count; *4 to rescale to 16-bit
6
+ before the calibration formula)
7
+ bits 14-16 RANGE (auto-range selector, 0-4; 5-7 = misaligned parse)
8
+ bit 17 reserved (read as 0; don't assert on it)
9
+ bits 18-23 COUNTER (6-bit, mod 64; what the stream parser
10
+ resyncs on)
11
+ bits 24-31 LOGIC (D0..D7; bit 0 = D0)
12
+ """
13
+
14
+ from dataclasses import dataclass
15
+
16
+
17
+ @dataclass(frozen=True, slots=True)
18
+ class RawSample:
19
+ """One sample frame after bit extraction: no calibration, no validation.
20
+
21
+ Attributes:
22
+ adc_14: Raw 14-bit ADC reading (0 to 16,383).
23
+ range: Auto-range index. Healthy firmware emits 0 to 4; 5 and up
24
+ means the parse is misaligned.
25
+ counter: 6-bit per-sample counter, incrementing mod 64.
26
+ logic: Digital inputs D0 to D7 in one byte (bit 0 is D0).
27
+ """
28
+
29
+ adc_14: int
30
+ range: int
31
+ counter: int
32
+ logic: int
33
+
34
+ def range_valid(self) -> bool:
35
+ """Whether the range index is one of the five real ranges."""
36
+ return self.range <= 4
37
+
38
+ def pin(self, pin: int) -> bool:
39
+ """Whether digital input ``pin`` (0 to 7) was high; ``pin`` wraps modulo 8."""
40
+ return ((self.logic >> (pin & 0x7)) & 1) != 0
41
+
42
+
43
+ def decode_sample(raw: int) -> RawSample:
44
+ """Split a 32-bit sample word into its fields (no validation)."""
45
+ return RawSample(
46
+ adc_14=raw & 0x3FFF,
47
+ range=(raw >> 14) & 0x07,
48
+ counter=(raw >> 18) & 0x3F,
49
+ logic=(raw >> 24) & 0xFF,
50
+ )
51
+
52
+
53
+ def decode_sample_bytes(buf: bytes) -> RawSample:
54
+ """Same as ``decode_sample``, from exactly 4 little-endian bytes.
55
+
56
+ Raises:
57
+ ValueError: If ``buf`` is not 4 bytes long.
58
+ """
59
+ if len(buf) != 4:
60
+ raise ValueError(f"expected 4 bytes, got {len(buf)}")
61
+ return decode_sample(int.from_bytes(buf, "little"))