ppk2-lib 0.1.0__py3-none-any.whl
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- ppk2/__init__.py +100 -0
- ppk2/__main__.py +5 -0
- ppk2/cli/__init__.py +3 -0
- ppk2/cli/commands/__init__.py +23 -0
- ppk2/cli/commands/capture.py +270 -0
- ppk2/cli/commands/convert.py +119 -0
- ppk2/cli/commands/discover.py +14 -0
- ppk2/cli/commands/list_devices.py +45 -0
- ppk2/cli/commands/metadata.py +36 -0
- ppk2/cli/commands/power.py +63 -0
- ppk2/cli/commands/run.py +162 -0
- ppk2/cli/csv.py +67 -0
- ppk2/cli/main.py +276 -0
- ppk2/cli/ppk2file.py +179 -0
- ppk2/cli/signals.py +46 -0
- ppk2/cli/trace.py +60 -0
- ppk2/client/__init__.py +50 -0
- ppk2/client/discovery.py +515 -0
- ppk2/client/session.py +639 -0
- ppk2/protocol/__init__.py +51 -0
- ppk2/protocol/calibration.py +51 -0
- ppk2/protocol/metadata.py +320 -0
- ppk2/protocol/opcode.py +110 -0
- ppk2/protocol/sample.py +61 -0
- ppk2/protocol/stream.py +375 -0
- ppk2/py.typed +0 -0
- ppk2_lib-0.1.0.dist-info/METADATA +164 -0
- ppk2_lib-0.1.0.dist-info/RECORD +32 -0
- ppk2_lib-0.1.0.dist-info/WHEEL +4 -0
- ppk2_lib-0.1.0.dist-info/entry_points.txt +2 -0
- ppk2_lib-0.1.0.dist-info/licenses/LICENSE-APACHE +202 -0
- ppk2_lib-0.1.0.dist-info/licenses/LICENSE-MIT +21 -0
ppk2/__init__.py
ADDED
|
@@ -0,0 +1,100 @@
|
|
|
1
|
+
"""Python library + CLI for Nordic's Power Profiler Kit II (PPK2).
|
|
2
|
+
|
|
3
|
+
Three layers:
|
|
4
|
+
|
|
5
|
+
- ``ppk2.protocol``: pure wire-protocol primitives, stdlib-only.
|
|
6
|
+
- ``ppk2.client``: sync host driver on top of ``pyserial``.
|
|
7
|
+
- ``ppk2.cli``: the ``ppk2`` binary, internal to the package.
|
|
8
|
+
|
|
9
|
+
For library use, import from this top level:
|
|
10
|
+
|
|
11
|
+
>>> from ppk2 import StreamParser, parse_metadata, Sample # protocol layer
|
|
12
|
+
>>> from ppk2 import Session, find_ppk2 # client layer
|
|
13
|
+
"""
|
|
14
|
+
|
|
15
|
+
from ppk2.client import (
|
|
16
|
+
USER_GAIN_MAX,
|
|
17
|
+
USER_GAIN_MIN,
|
|
18
|
+
VOLTAGE_LIMIT_HARDWARE_MAX_MV,
|
|
19
|
+
VOLTAGE_LIMIT_HARDWARE_MIN_MV,
|
|
20
|
+
Ambiguous,
|
|
21
|
+
DataPortNotFound,
|
|
22
|
+
DiscoveryError,
|
|
23
|
+
HandshakeFailed,
|
|
24
|
+
Mode,
|
|
25
|
+
NotFound,
|
|
26
|
+
PortInfo,
|
|
27
|
+
Ppk2Listing,
|
|
28
|
+
SerialIOError,
|
|
29
|
+
Session,
|
|
30
|
+
SessionError,
|
|
31
|
+
find_ppk2,
|
|
32
|
+
find_ppk2_by_serial,
|
|
33
|
+
list_ppk2s,
|
|
34
|
+
)
|
|
35
|
+
from ppk2.protocol import (
|
|
36
|
+
DEFAULT_SPIKE_FILTER_ALPHA,
|
|
37
|
+
DEFAULT_SPIKE_FILTER_ALPHA5,
|
|
38
|
+
DEFAULT_SPIKE_FILTER_SAMPLES,
|
|
39
|
+
MAX_BUFFERED_CORRUPTED,
|
|
40
|
+
NUM_RANGES,
|
|
41
|
+
CalibrationCoefficients,
|
|
42
|
+
InvalidValue,
|
|
43
|
+
MetadataError,
|
|
44
|
+
MissingEnd,
|
|
45
|
+
MissingField,
|
|
46
|
+
Opcode,
|
|
47
|
+
RangeArray,
|
|
48
|
+
RawSample,
|
|
49
|
+
Sample,
|
|
50
|
+
SpikeFilter,
|
|
51
|
+
StreamParser,
|
|
52
|
+
current_micro_amps,
|
|
53
|
+
decode_sample,
|
|
54
|
+
decode_sample_bytes,
|
|
55
|
+
parse_metadata,
|
|
56
|
+
)
|
|
57
|
+
|
|
58
|
+
__version__ = "0.1.0"
|
|
59
|
+
|
|
60
|
+
__all__ = [
|
|
61
|
+
"DEFAULT_SPIKE_FILTER_ALPHA",
|
|
62
|
+
"DEFAULT_SPIKE_FILTER_ALPHA5",
|
|
63
|
+
"DEFAULT_SPIKE_FILTER_SAMPLES",
|
|
64
|
+
"MAX_BUFFERED_CORRUPTED",
|
|
65
|
+
"NUM_RANGES",
|
|
66
|
+
"USER_GAIN_MAX",
|
|
67
|
+
"USER_GAIN_MIN",
|
|
68
|
+
"VOLTAGE_LIMIT_HARDWARE_MAX_MV",
|
|
69
|
+
"VOLTAGE_LIMIT_HARDWARE_MIN_MV",
|
|
70
|
+
"Ambiguous",
|
|
71
|
+
"CalibrationCoefficients",
|
|
72
|
+
"DataPortNotFound",
|
|
73
|
+
"DiscoveryError",
|
|
74
|
+
"HandshakeFailed",
|
|
75
|
+
"InvalidValue",
|
|
76
|
+
"MetadataError",
|
|
77
|
+
"MissingEnd",
|
|
78
|
+
"MissingField",
|
|
79
|
+
"Mode",
|
|
80
|
+
"NotFound",
|
|
81
|
+
"Opcode",
|
|
82
|
+
"PortInfo",
|
|
83
|
+
"Ppk2Listing",
|
|
84
|
+
"RangeArray",
|
|
85
|
+
"RawSample",
|
|
86
|
+
"Sample",
|
|
87
|
+
"SerialIOError",
|
|
88
|
+
"Session",
|
|
89
|
+
"SessionError",
|
|
90
|
+
"SpikeFilter",
|
|
91
|
+
"StreamParser",
|
|
92
|
+
"__version__",
|
|
93
|
+
"current_micro_amps",
|
|
94
|
+
"decode_sample",
|
|
95
|
+
"decode_sample_bytes",
|
|
96
|
+
"find_ppk2",
|
|
97
|
+
"find_ppk2_by_serial",
|
|
98
|
+
"list_ppk2s",
|
|
99
|
+
"parse_metadata",
|
|
100
|
+
]
|
ppk2/__main__.py
ADDED
ppk2/cli/__init__.py
ADDED
|
@@ -0,0 +1,23 @@
|
|
|
1
|
+
"""Per-subcommand modules for the ``ppk2`` CLI.
|
|
2
|
+
|
|
3
|
+
``resolve_device``, shared by all of them, turns the ``--serial`` /
|
|
4
|
+
``--port`` flag pair into a device path.
|
|
5
|
+
"""
|
|
6
|
+
|
|
7
|
+
from ppk2 import Mode, find_ppk2, find_ppk2_by_serial
|
|
8
|
+
|
|
9
|
+
#: The modes under the names of Nordic's app, for messages.
|
|
10
|
+
MODE_LABELS: dict[int, str] = {Mode.AMPERE: "Ampere meter", Mode.SOURCE: "Source meter"}
|
|
11
|
+
|
|
12
|
+
|
|
13
|
+
def resolve_device(serial: str | None, port: str | None) -> str:
|
|
14
|
+
"""Resolve the data-port path from the ``--serial``/``--port`` flags.
|
|
15
|
+
|
|
16
|
+
``--port`` wins and skips discovery and the probe: the caller says
|
|
17
|
+
they know the path. Otherwise discovery runs, scoped to ``--serial``
|
|
18
|
+
when given.
|
|
19
|
+
"""
|
|
20
|
+
if port is not None:
|
|
21
|
+
return port
|
|
22
|
+
info = find_ppk2_by_serial(serial) if serial else find_ppk2()
|
|
23
|
+
return info.device
|
|
@@ -0,0 +1,270 @@
|
|
|
1
|
+
"""``ppk2 capture``: stream the current trace to a CSV or ``.ppk2`` file."""
|
|
2
|
+
|
|
3
|
+
import signal
|
|
4
|
+
import sys
|
|
5
|
+
from collections.abc import Callable, Iterable
|
|
6
|
+
from contextlib import ExitStack, suppress
|
|
7
|
+
from math import isfinite, isnan
|
|
8
|
+
from pathlib import Path
|
|
9
|
+
from time import monotonic
|
|
10
|
+
from types import FrameType
|
|
11
|
+
|
|
12
|
+
import typer
|
|
13
|
+
|
|
14
|
+
from ppk2 import USER_GAIN_MAX, USER_GAIN_MIN, Mode, Sample, Session
|
|
15
|
+
from ppk2.cli.commands import MODE_LABELS, resolve_device
|
|
16
|
+
from ppk2.cli.csv import noise_floor, vdd_to_mv
|
|
17
|
+
from ppk2.cli.signals import signals_to_systemexit
|
|
18
|
+
from ppk2.cli.trace import SAMPLE_RATE_HZ as _SAMPLE_RATE_HZ
|
|
19
|
+
from ppk2.cli.trace import TraceFile
|
|
20
|
+
|
|
21
|
+
_PROGRESS_INTERVAL_S = 1.0
|
|
22
|
+
|
|
23
|
+
#: Cumulative data-loss count at which we first emit a mid-stream
|
|
24
|
+
#: warning. Matches ``DATALOSS_THRESHOLD`` in Nordic's app.
|
|
25
|
+
_DATALOSS_WARN_THRESHOLD = 500
|
|
26
|
+
|
|
27
|
+
#: Post-capture watchdog: a realized stream rate below this fraction of
|
|
28
|
+
#: 100 kSPS (on captures longer than 0.5 s) means the host lost
|
|
29
|
+
#: samples, and charge or timing figures taken from the file are off.
|
|
30
|
+
_RATE_WATCHDOG_FRACTION = 0.95
|
|
31
|
+
|
|
32
|
+
#: How long past ``--seconds`` a capture waits for samples that are late.
|
|
33
|
+
_LATE_GRACE_S = 1.0
|
|
34
|
+
|
|
35
|
+
|
|
36
|
+
def capture(
|
|
37
|
+
serial: str | None,
|
|
38
|
+
port: str | None,
|
|
39
|
+
out: Path,
|
|
40
|
+
seconds: float,
|
|
41
|
+
vdd: float,
|
|
42
|
+
source: bool,
|
|
43
|
+
user_gain_specs: Iterable[str] = (),
|
|
44
|
+
) -> None:
|
|
45
|
+
"""Open a session, stream samples for ``seconds``, write them to ``out``.
|
|
46
|
+
|
|
47
|
+
The 11-column CSV, or a ``.ppk2`` session file when ``out`` ends in ``.ppk2``.
|
|
48
|
+
"""
|
|
49
|
+
# Parse the gains first: a malformed flag should fail before the
|
|
50
|
+
# (slow) hardware discovery, not after.
|
|
51
|
+
user_gains = [parse_user_gain_spec(spec) for spec in user_gain_specs]
|
|
52
|
+
if not (isfinite(seconds) and round(seconds * _SAMPLE_RATE_HZ) >= 1):
|
|
53
|
+
raise typer.BadParameter(
|
|
54
|
+
f"{seconds} is not a duration: give at least one sample, 0.00001 s",
|
|
55
|
+
param_hint="--seconds",
|
|
56
|
+
)
|
|
57
|
+
mv = vdd_to_mv(vdd)
|
|
58
|
+
device = resolve_device(serial, port)
|
|
59
|
+
mode = Mode.SOURCE if source else Mode.AMPERE
|
|
60
|
+
|
|
61
|
+
sys.stderr.write(f"opening session ({MODE_LABELS[mode]} mode, vdd={mv} mV)\n")
|
|
62
|
+
if user_gains:
|
|
63
|
+
gains_repr = ", ".join(f"r{r}={g:.4f}" for r, g in user_gains)
|
|
64
|
+
sys.stderr.write(f" user-gain overrides: {gains_repr}\n")
|
|
65
|
+
sys.stderr.write(f"capturing {seconds:.2f} s -> {out} (Ctrl-C to stop early)\n")
|
|
66
|
+
sys.stderr.flush()
|
|
67
|
+
|
|
68
|
+
out.parent.mkdir(parents=True, exist_ok=True)
|
|
69
|
+
|
|
70
|
+
stop_requested = _SigintFlag()
|
|
71
|
+
|
|
72
|
+
# SIGTERM/SIGHUP raise SystemExit inside this block, so a `kill` or
|
|
73
|
+
# a closed terminal unwinds it like a Ctrl-C: the session tears
|
|
74
|
+
# down and the output file is completed.
|
|
75
|
+
with ExitStack() as stack:
|
|
76
|
+
stack.enter_context(stop_requested)
|
|
77
|
+
stack.enter_context(signals_to_systemexit("SIGTERM", "SIGHUP"))
|
|
78
|
+
|
|
79
|
+
with Session.open(device) as session:
|
|
80
|
+
# Opened once the PPK2 answers: a capture that cannot start
|
|
81
|
+
# leaves an earlier file of the same name alone.
|
|
82
|
+
trace = stack.enter_context(TraceFile(out))
|
|
83
|
+
session.set_mode(mode)
|
|
84
|
+
session.set_source_voltage(mv)
|
|
85
|
+
for range_idx, gain in user_gains:
|
|
86
|
+
session.set_user_gain(range_idx, gain)
|
|
87
|
+
session.start_measuring()
|
|
88
|
+
session.power_on()
|
|
89
|
+
|
|
90
|
+
n_samples = 0
|
|
91
|
+
n_dataloss = 0 # NaN placeholders from the stream parser's data-loss path
|
|
92
|
+
sum_ua = 0.0
|
|
93
|
+
last_progress = monotonic()
|
|
94
|
+
started = monotonic()
|
|
95
|
+
# The capture ends on a number of samples, so that the
|
|
96
|
+
# trace holds the seconds asked for. The clock ends it only
|
|
97
|
+
# when the samples do not come.
|
|
98
|
+
target = round(seconds * _SAMPLE_RATE_HZ)
|
|
99
|
+
deadline = started + seconds + _LATE_GRACE_S
|
|
100
|
+
dataloss_warned = False
|
|
101
|
+
|
|
102
|
+
def on_dataloss(total: int) -> None:
|
|
103
|
+
nonlocal dataloss_warned
|
|
104
|
+
if dataloss_warned or total < _DATALOSS_WARN_THRESHOLD:
|
|
105
|
+
return
|
|
106
|
+
dataloss_warned = True
|
|
107
|
+
sys.stderr.write(
|
|
108
|
+
f" warning: {total} samples lost so far, near sample "
|
|
109
|
+
f"{n_samples + n_dataloss}. Likely cause: the USB cable, a hub or a "
|
|
110
|
+
"busy computer. The capture goes on; each lost sample is recorded "
|
|
111
|
+
"as 0.2 µA, as in Nordic's app.\n"
|
|
112
|
+
)
|
|
113
|
+
sys.stderr.flush()
|
|
114
|
+
|
|
115
|
+
def emit(s: Sample) -> bool:
|
|
116
|
+
nonlocal n_samples, n_dataloss, sum_ua, last_progress
|
|
117
|
+
if stop_requested.flag:
|
|
118
|
+
return False
|
|
119
|
+
# NaN is a lost sample: 0.2 µA in the file, as in
|
|
120
|
+
# Nordic's app, and left out of the mean printed here.
|
|
121
|
+
ua = noise_floor(s.current_micro_amps)
|
|
122
|
+
trace.add(ua, s.logic)
|
|
123
|
+
if isnan(ua):
|
|
124
|
+
n_dataloss += 1
|
|
125
|
+
else:
|
|
126
|
+
n_samples += 1
|
|
127
|
+
sum_ua += ua
|
|
128
|
+
|
|
129
|
+
now = monotonic()
|
|
130
|
+
if now - last_progress >= _PROGRESS_INTERVAL_S:
|
|
131
|
+
mean = sum_ua / n_samples if n_samples else 0.0
|
|
132
|
+
elapsed = now - started
|
|
133
|
+
sys.stderr.write(
|
|
134
|
+
f" [{elapsed:5.1f}s] {n_samples:>10} samples mean {mean:>7.2f} µA\n"
|
|
135
|
+
)
|
|
136
|
+
sys.stderr.flush()
|
|
137
|
+
last_progress = now
|
|
138
|
+
|
|
139
|
+
return n_samples + n_dataloss < target and monotonic() < deadline
|
|
140
|
+
|
|
141
|
+
# The trace starts about 10 ms before power-on (Known
|
|
142
|
+
# caveats in docs/measure/protocol.md).
|
|
143
|
+
session.drop_pending_backlog()
|
|
144
|
+
session.capture(
|
|
145
|
+
emit,
|
|
146
|
+
on_dataloss=on_dataloss,
|
|
147
|
+
# A silent PPK2 never reaches emit: the clock and
|
|
148
|
+
# Ctrl-C are checked here too.
|
|
149
|
+
keep_going=lambda: not stop_requested.flag and monotonic() < deadline,
|
|
150
|
+
)
|
|
151
|
+
# Taken here: shutting the session down takes a tenth of a
|
|
152
|
+
# second that is not capture time.
|
|
153
|
+
wall = monotonic() - started
|
|
154
|
+
|
|
155
|
+
with suppress(Exception):
|
|
156
|
+
session.power_off()
|
|
157
|
+
with suppress(Exception):
|
|
158
|
+
session.stop_measuring()
|
|
159
|
+
|
|
160
|
+
# Complete the file before saying so, with the signal handlers
|
|
161
|
+
# still in place: a second Ctrl-C must not cut the write short.
|
|
162
|
+
trace.close()
|
|
163
|
+
# The stream rate counts lost samples too: they took their time.
|
|
164
|
+
n_total = n_samples + n_dataloss
|
|
165
|
+
rate = n_total / wall if wall > 0 else 0.0
|
|
166
|
+
if stop_requested.flag:
|
|
167
|
+
done = ".ppk2 written" if trace.is_ppk2 else "CSV flushed"
|
|
168
|
+
sys.stderr.write(f"interrupted: {done}\n")
|
|
169
|
+
suffix = ", stopped by Ctrl-C" if stop_requested.flag else ""
|
|
170
|
+
sys.stderr.write(
|
|
171
|
+
f"captured {n_samples} samples over {wall:.2f} s ({rate:.0f} Hz){suffix}\n"
|
|
172
|
+
)
|
|
173
|
+
if n_dataloss > 0:
|
|
174
|
+
sys.stderr.write(
|
|
175
|
+
f" warning: {n_dataloss} samples lost "
|
|
176
|
+
f"({100.0 * n_dataloss / n_total:.3f} % of the stream), "
|
|
177
|
+
"each recorded as 0.2 µA, as in Nordic's app\n"
|
|
178
|
+
)
|
|
179
|
+
if wall > 0.5 and n_total > 0 and rate < _RATE_WATCHDOG_FRACTION * _SAMPLE_RATE_HZ:
|
|
180
|
+
sys.stderr.write(
|
|
181
|
+
f"WARNING: stream rate {rate:.0f} Hz is "
|
|
182
|
+
f"{100.0 * rate / _SAMPLE_RATE_HZ:.1f} % of {_SAMPLE_RATE_HZ} Hz "
|
|
183
|
+
f"({n_total} samples in {wall:.2f} s): samples were lost without "
|
|
184
|
+
"being counted; do not rely on the duration or the charge of this capture.\n"
|
|
185
|
+
)
|
|
186
|
+
sys.stderr.flush()
|
|
187
|
+
|
|
188
|
+
if stop_requested.flag:
|
|
189
|
+
# 130 is the standard Bash SIGINT exit code. The output is
|
|
190
|
+
# completed as the block unwinds: shorter, but valid.
|
|
191
|
+
raise typer.Exit(code=130)
|
|
192
|
+
if n_total == 0:
|
|
193
|
+
sys.stderr.write(
|
|
194
|
+
"error: no samples captured: check the PPK2 mode and the DUT's power\n"
|
|
195
|
+
)
|
|
196
|
+
sys.stderr.flush()
|
|
197
|
+
raise typer.Exit(code=1)
|
|
198
|
+
if n_total < target:
|
|
199
|
+
# The clock ended it: the file is kept, and is not what was asked for.
|
|
200
|
+
sys.stderr.write(
|
|
201
|
+
f"error: capture ended with {n_total} of {target} samples: "
|
|
202
|
+
"the PPK2 stopped sending, or the computer did not keep up\n"
|
|
203
|
+
)
|
|
204
|
+
sys.stderr.flush()
|
|
205
|
+
raise typer.Exit(code=1)
|
|
206
|
+
|
|
207
|
+
|
|
208
|
+
def parse_user_gain_spec(spec: str) -> tuple[int, float]:
|
|
209
|
+
"""Parse one ``--user-gain RANGE:GAIN`` token into ``(range_idx, gain)``.
|
|
210
|
+
|
|
211
|
+
Raises:
|
|
212
|
+
typer.BadParameter: If it is not ``RANGE:GAIN``, the range is not
|
|
213
|
+
0-4, or the gain is not from 0.9 to 1.1.
|
|
214
|
+
"""
|
|
215
|
+
label = "--user-gain"
|
|
216
|
+
parts = spec.split(":")
|
|
217
|
+
if len(parts) != 2:
|
|
218
|
+
raise typer.BadParameter(
|
|
219
|
+
f"{label} expects RANGE:GAIN (got '{spec}'); example: --user-gain 2:1.05",
|
|
220
|
+
param_hint=label,
|
|
221
|
+
)
|
|
222
|
+
range_str, gain_str = parts[0].strip(), parts[1].strip()
|
|
223
|
+
try:
|
|
224
|
+
range_idx = int(range_str)
|
|
225
|
+
except ValueError as exc:
|
|
226
|
+
raise typer.BadParameter(
|
|
227
|
+
f"{label} range must be an integer from 0 to 4 (got '{range_str}')",
|
|
228
|
+
param_hint=label,
|
|
229
|
+
) from exc
|
|
230
|
+
if not 0 <= range_idx <= 4:
|
|
231
|
+
raise typer.BadParameter(
|
|
232
|
+
f"{label} range must be from 0 to 4 (got {range_idx})",
|
|
233
|
+
param_hint=label,
|
|
234
|
+
)
|
|
235
|
+
try:
|
|
236
|
+
gain = float(gain_str)
|
|
237
|
+
except ValueError as exc:
|
|
238
|
+
raise typer.BadParameter(
|
|
239
|
+
f"{label} gain must be a float (got '{gain_str}')",
|
|
240
|
+
param_hint=label,
|
|
241
|
+
) from exc
|
|
242
|
+
# The range of Nordic's app. NaN fails the comparison too.
|
|
243
|
+
if not USER_GAIN_MIN <= gain <= USER_GAIN_MAX:
|
|
244
|
+
raise typer.BadParameter(
|
|
245
|
+
f"{label} gain must be from {USER_GAIN_MIN} to {USER_GAIN_MAX} (got '{gain_str}')",
|
|
246
|
+
param_hint=label,
|
|
247
|
+
)
|
|
248
|
+
return range_idx, gain
|
|
249
|
+
|
|
250
|
+
|
|
251
|
+
# What `signal.signal` returns: SIG_DFL / SIG_IGN or a Python callable.
|
|
252
|
+
_SignalHandler = Callable[[int, FrameType | None], object] | int | None
|
|
253
|
+
|
|
254
|
+
|
|
255
|
+
class _SigintFlag:
|
|
256
|
+
"""A SIGINT handler that sets ``flag``; the previous handler comes back on exit."""
|
|
257
|
+
|
|
258
|
+
def __init__(self) -> None:
|
|
259
|
+
self.flag = False
|
|
260
|
+
self._prev: _SignalHandler = signal.SIG_DFL
|
|
261
|
+
|
|
262
|
+
def __enter__(self) -> "_SigintFlag":
|
|
263
|
+
def _handler(_signum: int, _frame: FrameType | None) -> None:
|
|
264
|
+
self.flag = True
|
|
265
|
+
|
|
266
|
+
self._prev = signal.signal(signal.SIGINT, _handler)
|
|
267
|
+
return self
|
|
268
|
+
|
|
269
|
+
def __exit__(self, *_args: object) -> None:
|
|
270
|
+
signal.signal(signal.SIGINT, self._prev)
|
|
@@ -0,0 +1,119 @@
|
|
|
1
|
+
"""``ppk2 convert``: rewrite a CSV capture as a ``.ppk2`` session file."""
|
|
2
|
+
|
|
3
|
+
import gzip
|
|
4
|
+
import struct
|
|
5
|
+
import sys
|
|
6
|
+
from itertools import chain, islice, pairwise
|
|
7
|
+
from pathlib import Path
|
|
8
|
+
from typing import NoReturn, TextIO
|
|
9
|
+
|
|
10
|
+
import typer
|
|
11
|
+
|
|
12
|
+
from ppk2.cli.ppk2file import SAMPLE_RATES, Ppk2FileWriter
|
|
13
|
+
from ppk2.cli.trace import LOST_SAMPLE_UA
|
|
14
|
+
|
|
15
|
+
# Rows read ahead to find the sample period: enough to hold two
|
|
16
|
+
# neighbouring samples even where some were lost.
|
|
17
|
+
_ROWS_FOR_RATE = 64
|
|
18
|
+
|
|
19
|
+
|
|
20
|
+
def convert(src: Path, dst: Path) -> None:
|
|
21
|
+
"""Rewrite the CSV capture ``src`` (plain or ``.gz``) as the ``.ppk2`` file ``dst``.
|
|
22
|
+
|
|
23
|
+
The sample rate is the smallest step between the first timestamps.
|
|
24
|
+
A ``.ppk2`` has no timestamps, so a jump in those of the CSV is
|
|
25
|
+
filled: one frame of ``LOST_SAMPLE_UA`` per missing row, as Nordic's
|
|
26
|
+
app records a lost sample, and the rest of the trace stays where it
|
|
27
|
+
was in time.
|
|
28
|
+
|
|
29
|
+
On any error nothing is written, and an existing ``dst`` is kept.
|
|
30
|
+
"""
|
|
31
|
+
try:
|
|
32
|
+
count, rate, lost = _convert(src, dst)
|
|
33
|
+
except UnicodeDecodeError:
|
|
34
|
+
_fail(f"{src}: not a text file")
|
|
35
|
+
except EOFError:
|
|
36
|
+
_fail(f"{src}: the compressed file is cut short")
|
|
37
|
+
except OSError as exc:
|
|
38
|
+
_fail(f"{exc.filename or src}: {exc.strerror or exc}")
|
|
39
|
+
|
|
40
|
+
note = ""
|
|
41
|
+
if lost:
|
|
42
|
+
note = (
|
|
43
|
+
", 1 missing row filled with 0.2 µA"
|
|
44
|
+
if lost == 1
|
|
45
|
+
else f", {lost} missing rows filled with 0.2 µA"
|
|
46
|
+
)
|
|
47
|
+
sys.stderr.write(f"wrote {dst}: {count} samples at {rate} S/s ({count / rate:.2f} s){note}\n")
|
|
48
|
+
|
|
49
|
+
|
|
50
|
+
def _convert(src: Path, dst: Path) -> tuple[int, int, int]:
|
|
51
|
+
"""Do the conversion; return (samples written, rate, lost samples among them)."""
|
|
52
|
+
with _open_text(src) as rows:
|
|
53
|
+
columns = rows.readline().strip().split(",")
|
|
54
|
+
if "Timestamp(ms)" not in columns or "Current(uA)" not in columns:
|
|
55
|
+
_fail(f"{src}: needs the Timestamp(ms) and Current(uA) columns")
|
|
56
|
+
i_time = columns.index("Timestamp(ms)")
|
|
57
|
+
i_current = columns.index("Current(uA)")
|
|
58
|
+
i_logic = columns.index("D0-D7") if "D0-D7" in columns else None
|
|
59
|
+
|
|
60
|
+
head = list(islice(rows, _ROWS_FOR_RATE))
|
|
61
|
+
try:
|
|
62
|
+
times = [float(line.split(",")[i_time]) for line in head if line.strip()]
|
|
63
|
+
except (ValueError, IndexError):
|
|
64
|
+
_fail(f"{src}: cannot read the timestamps of the first rows")
|
|
65
|
+
if not times:
|
|
66
|
+
_fail(f"{src}: no samples")
|
|
67
|
+
step_ms = min((b - a for a, b in pairwise(times) if b > a), default=0.01)
|
|
68
|
+
rate = round(1000.0 / step_ms)
|
|
69
|
+
if rate not in SAMPLE_RATES:
|
|
70
|
+
_fail(f"{src}: {step_ms:g} ms between samples is not a rate the app supports")
|
|
71
|
+
t0 = times[0]
|
|
72
|
+
|
|
73
|
+
dst.parent.mkdir(parents=True, exist_ok=True)
|
|
74
|
+
logic_of: dict[str, int] = {} # "10000000" (D0 leftmost) -> 0x01
|
|
75
|
+
lost = 0
|
|
76
|
+
out = Ppk2FileWriter(dst, rate)
|
|
77
|
+
try:
|
|
78
|
+
for row, line in enumerate(chain(head, rows), start=2):
|
|
79
|
+
if not line.strip():
|
|
80
|
+
continue
|
|
81
|
+
fields = line.split(",")
|
|
82
|
+
try:
|
|
83
|
+
slot = round((float(fields[i_time]) - t0) * rate / 1000.0)
|
|
84
|
+
current = float(fields[i_current])
|
|
85
|
+
logic = 0
|
|
86
|
+
if i_logic is not None:
|
|
87
|
+
bits = fields[i_logic].strip()
|
|
88
|
+
logic = logic_of.get(bits, -1)
|
|
89
|
+
if logic < 0:
|
|
90
|
+
logic = logic_of[bits] = int(bits[::-1], 2)
|
|
91
|
+
except (ValueError, IndexError):
|
|
92
|
+
_fail(f"{src}: malformed row at line {row}")
|
|
93
|
+
if slot < out.count:
|
|
94
|
+
_fail(f"{src}: timestamps go back at line {row}")
|
|
95
|
+
if slot - out.count > rate:
|
|
96
|
+
_fail(f"{src}: timestamps jump by over a second at line {row}")
|
|
97
|
+
for _ in range(slot - out.count):
|
|
98
|
+
out.add(LOST_SAMPLE_UA, 0)
|
|
99
|
+
lost += 1
|
|
100
|
+
try:
|
|
101
|
+
out.add(current, logic)
|
|
102
|
+
except (OverflowError, struct.error):
|
|
103
|
+
_fail(f"{src}: current out of range at line {row}")
|
|
104
|
+
except BaseException:
|
|
105
|
+
out.discard()
|
|
106
|
+
raise
|
|
107
|
+
out.close()
|
|
108
|
+
return out.count, rate, lost
|
|
109
|
+
|
|
110
|
+
|
|
111
|
+
def _open_text(path: Path) -> TextIO:
|
|
112
|
+
if path.suffix == ".gz":
|
|
113
|
+
return gzip.open(path, "rt", encoding="utf-8")
|
|
114
|
+
return path.open(encoding="utf-8")
|
|
115
|
+
|
|
116
|
+
|
|
117
|
+
def _fail(message: str) -> NoReturn:
|
|
118
|
+
sys.stderr.write(f"error: {message}\n")
|
|
119
|
+
raise typer.Exit(code=1)
|
|
@@ -0,0 +1,14 @@
|
|
|
1
|
+
"""``ppk2 discover``: print the data-port device path of the plugged-in PPK2."""
|
|
2
|
+
|
|
3
|
+
import typer
|
|
4
|
+
|
|
5
|
+
from ppk2.cli.commands import resolve_device
|
|
6
|
+
|
|
7
|
+
|
|
8
|
+
def discover(serial: str | None, port: str | None) -> None:
|
|
9
|
+
"""Resolve the PPK2 and print its data-port device path to stdout.
|
|
10
|
+
|
|
11
|
+
With ``--port`` the path is echoed back as given, with no discovery
|
|
12
|
+
and no probe, so scripts can pass the flag to every subcommand.
|
|
13
|
+
"""
|
|
14
|
+
typer.echo(resolve_device(serial, port))
|
|
@@ -0,0 +1,45 @@
|
|
|
1
|
+
"""``ppk2 list``: enumerate connected PPK2s and mark each port's probe status."""
|
|
2
|
+
|
|
3
|
+
import typer
|
|
4
|
+
|
|
5
|
+
from ppk2 import list_ppk2s
|
|
6
|
+
from ppk2.client.discovery import PortStatus
|
|
7
|
+
|
|
8
|
+
_STATUS_TAGS: dict[PortStatus, str] = {
|
|
9
|
+
"data": "[data port]",
|
|
10
|
+
"idle": "[idle]",
|
|
11
|
+
"busy": "[busy: held by another process?]",
|
|
12
|
+
}
|
|
13
|
+
|
|
14
|
+
|
|
15
|
+
def list_devices(mask_serial: bool = False) -> None:
|
|
16
|
+
"""Print one block per physical PPK2 with each port's probe status.
|
|
17
|
+
|
|
18
|
+
Exit code 0 when every enumerated device has an identified data
|
|
19
|
+
port; 1 when none is plugged in or when a device's data port could
|
|
20
|
+
not be identified (typically because another process holds it).
|
|
21
|
+
|
|
22
|
+
With ``mask_serial`` only the last four characters of each serial
|
|
23
|
+
number are printed, in the port paths too: for a screenshot or a
|
|
24
|
+
recording.
|
|
25
|
+
"""
|
|
26
|
+
devices = list_ppk2s()
|
|
27
|
+
if not devices:
|
|
28
|
+
typer.echo("no PPK2 found")
|
|
29
|
+
raise typer.Exit(code=1)
|
|
30
|
+
unidentified = False
|
|
31
|
+
for dev in devices:
|
|
32
|
+
serial = dev.usb_serial
|
|
33
|
+
masked = "*" * (len(serial) - 4) + serial[-4:] if mask_serial else serial
|
|
34
|
+
typer.echo(f"PPK2 serial={masked}")
|
|
35
|
+
for path in dev.ports:
|
|
36
|
+
shown = path.replace(serial, masked) if serial else path
|
|
37
|
+
typer.echo(f" {shown} {_STATUS_TAGS[dev.statuses[path]]}")
|
|
38
|
+
if dev.data_port is None:
|
|
39
|
+
unidentified = True
|
|
40
|
+
typer.echo(
|
|
41
|
+
" (data port not identified: close the nRF Connect Power "
|
|
42
|
+
"Profiler if it's open, else pass --port)"
|
|
43
|
+
)
|
|
44
|
+
if unidentified:
|
|
45
|
+
raise typer.Exit(code=1)
|
|
@@ -0,0 +1,36 @@
|
|
|
1
|
+
"""``ppk2 metadata``: print the per-device calibration coefficients."""
|
|
2
|
+
|
|
3
|
+
import typer
|
|
4
|
+
|
|
5
|
+
from ppk2 import CalibrationCoefficients, Session
|
|
6
|
+
from ppk2.cli.commands import MODE_LABELS, resolve_device
|
|
7
|
+
from ppk2.cli.signals import signals_to_systemexit
|
|
8
|
+
|
|
9
|
+
|
|
10
|
+
def metadata(serial: str | None, port: str | None) -> None:
|
|
11
|
+
"""Open a session, read metadata, format-print to stdout, then teardown."""
|
|
12
|
+
device = resolve_device(serial, port)
|
|
13
|
+
with signals_to_systemexit("SIGTERM", "SIGHUP"), Session.open(device) as session:
|
|
14
|
+
coeffs = session.coefficients()
|
|
15
|
+
_print_coefficients(coeffs)
|
|
16
|
+
|
|
17
|
+
|
|
18
|
+
def _print_coefficients(c: CalibrationCoefficients) -> None:
|
|
19
|
+
"""Render the coefficient block as a human-readable table."""
|
|
20
|
+
mode_name = MODE_LABELS.get(c.mode, "unknown")
|
|
21
|
+
typer.echo(f"Calibrated: {'true' if c.calibrated else 'false'}")
|
|
22
|
+
typer.echo(f"HW: {c.hw}")
|
|
23
|
+
typer.echo(f"IA: {c.ia}")
|
|
24
|
+
typer.echo(f"VDD: {c.vdd_mv} mV")
|
|
25
|
+
typer.echo(f"mode: {c.mode} ({mode_name})")
|
|
26
|
+
for name, arr in (
|
|
27
|
+
("R ", c.r),
|
|
28
|
+
("GS", c.gs),
|
|
29
|
+
("GI", c.gi),
|
|
30
|
+
("O ", c.o),
|
|
31
|
+
("S ", c.s),
|
|
32
|
+
("I ", c.i),
|
|
33
|
+
("UG", c.ug),
|
|
34
|
+
):
|
|
35
|
+
formatted = ", ".join(f"{v: 16.6e}" for v in arr)
|
|
36
|
+
typer.echo(f"{name}: [{formatted}]")
|
|
@@ -0,0 +1,63 @@
|
|
|
1
|
+
"""``ppk2 power on|off``: switch power to the DUT, optionally holding it on."""
|
|
2
|
+
|
|
3
|
+
import signal
|
|
4
|
+
import sys
|
|
5
|
+
from enum import StrEnum
|
|
6
|
+
|
|
7
|
+
from ppk2 import Mode, Session
|
|
8
|
+
from ppk2.cli.commands import resolve_device
|
|
9
|
+
from ppk2.cli.csv import vdd_to_mv
|
|
10
|
+
from ppk2.cli.signals import signals_to_systemexit
|
|
11
|
+
|
|
12
|
+
|
|
13
|
+
class PowerState(StrEnum):
|
|
14
|
+
"""``on`` / ``off`` argument shape for ``ppk2 power``."""
|
|
15
|
+
|
|
16
|
+
ON = "on"
|
|
17
|
+
OFF = "off"
|
|
18
|
+
|
|
19
|
+
|
|
20
|
+
def power(
|
|
21
|
+
serial: str | None,
|
|
22
|
+
port: str | None,
|
|
23
|
+
state: PowerState,
|
|
24
|
+
hold: bool,
|
|
25
|
+
vdd: float,
|
|
26
|
+
source: bool,
|
|
27
|
+
) -> None:
|
|
28
|
+
"""Open a session, switch the power, optionally block until SIGINT, then close."""
|
|
29
|
+
mv = vdd_to_mv(vdd)
|
|
30
|
+
device = resolve_device(serial, port)
|
|
31
|
+
mode = Mode.SOURCE if source else Mode.AMPERE
|
|
32
|
+
|
|
33
|
+
# SIGTERM/SIGHUP -> SystemExit so a kill still cuts the power and
|
|
34
|
+
# closes the port on the way out.
|
|
35
|
+
with signals_to_systemexit("SIGTERM", "SIGHUP"), Session.open(device) as session:
|
|
36
|
+
session.set_mode(mode)
|
|
37
|
+
session.set_source_voltage(mv)
|
|
38
|
+
if state is PowerState.ON:
|
|
39
|
+
session.power_on()
|
|
40
|
+
if hold:
|
|
41
|
+
_hold_until_sigint()
|
|
42
|
+
# Without --hold the power goes off as the session closes.
|
|
43
|
+
else:
|
|
44
|
+
session.power_off()
|
|
45
|
+
|
|
46
|
+
|
|
47
|
+
def _hold_until_sigint() -> None:
|
|
48
|
+
"""Block until SIGINT, then return so the caller can clean up."""
|
|
49
|
+
received = False
|
|
50
|
+
|
|
51
|
+
def _handler(_signum: int, _frame: object) -> None:
|
|
52
|
+
nonlocal received
|
|
53
|
+
received = True
|
|
54
|
+
|
|
55
|
+
prev = signal.signal(signal.SIGINT, _handler)
|
|
56
|
+
try:
|
|
57
|
+
sys.stderr.write("ppk2: holding power on; Ctrl-C to release\n")
|
|
58
|
+
sys.stderr.flush()
|
|
59
|
+
signal.pause() # blocks until any signal; our handler unblocks SIGINT
|
|
60
|
+
if not received:
|
|
61
|
+
sys.stderr.write("ppk2: woke from pause without SIGINT, exiting anyway\n")
|
|
62
|
+
finally:
|
|
63
|
+
signal.signal(signal.SIGINT, prev)
|