ppk2-lib 0.1.0__py3-none-any.whl
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- ppk2/__init__.py +100 -0
- ppk2/__main__.py +5 -0
- ppk2/cli/__init__.py +3 -0
- ppk2/cli/commands/__init__.py +23 -0
- ppk2/cli/commands/capture.py +270 -0
- ppk2/cli/commands/convert.py +119 -0
- ppk2/cli/commands/discover.py +14 -0
- ppk2/cli/commands/list_devices.py +45 -0
- ppk2/cli/commands/metadata.py +36 -0
- ppk2/cli/commands/power.py +63 -0
- ppk2/cli/commands/run.py +162 -0
- ppk2/cli/csv.py +67 -0
- ppk2/cli/main.py +276 -0
- ppk2/cli/ppk2file.py +179 -0
- ppk2/cli/signals.py +46 -0
- ppk2/cli/trace.py +60 -0
- ppk2/client/__init__.py +50 -0
- ppk2/client/discovery.py +515 -0
- ppk2/client/session.py +639 -0
- ppk2/protocol/__init__.py +51 -0
- ppk2/protocol/calibration.py +51 -0
- ppk2/protocol/metadata.py +320 -0
- ppk2/protocol/opcode.py +110 -0
- ppk2/protocol/sample.py +61 -0
- ppk2/protocol/stream.py +375 -0
- ppk2/py.typed +0 -0
- ppk2_lib-0.1.0.dist-info/METADATA +164 -0
- ppk2_lib-0.1.0.dist-info/RECORD +32 -0
- ppk2_lib-0.1.0.dist-info/WHEEL +4 -0
- ppk2_lib-0.1.0.dist-info/entry_points.txt +2 -0
- ppk2_lib-0.1.0.dist-info/licenses/LICENSE-APACHE +202 -0
- ppk2_lib-0.1.0.dist-info/licenses/LICENSE-MIT +21 -0
ppk2/client/session.py
ADDED
|
@@ -0,0 +1,639 @@
|
|
|
1
|
+
"""PPK2 session lifecycle: open, configure, stream, tear down.
|
|
2
|
+
|
|
3
|
+
``Session`` is a context manager; leaving the block stops the stream,
|
|
4
|
+
switches the DUT off and closes the port.
|
|
5
|
+
|
|
6
|
+
>>> with Session.open(port) as s:
|
|
7
|
+
... s.set_mode(Mode.AMPERE)
|
|
8
|
+
... s.set_source_voltage(3300)
|
|
9
|
+
... s.start_measuring()
|
|
10
|
+
... s.power_on()
|
|
11
|
+
... s.capture(on_sample) # until on_sample returns False
|
|
12
|
+
"""
|
|
13
|
+
|
|
14
|
+
import warnings
|
|
15
|
+
from collections.abc import Callable
|
|
16
|
+
from contextlib import suppress
|
|
17
|
+
from dataclasses import replace
|
|
18
|
+
from enum import IntEnum
|
|
19
|
+
from time import monotonic, sleep
|
|
20
|
+
from typing import Protocol
|
|
21
|
+
|
|
22
|
+
import serial
|
|
23
|
+
|
|
24
|
+
from ppk2.protocol import (
|
|
25
|
+
CalibrationCoefficients,
|
|
26
|
+
MetadataError,
|
|
27
|
+
Opcode,
|
|
28
|
+
RangeArray,
|
|
29
|
+
Sample,
|
|
30
|
+
SpikeFilter,
|
|
31
|
+
StreamParser,
|
|
32
|
+
parse_metadata,
|
|
33
|
+
)
|
|
34
|
+
|
|
35
|
+
_BAUD_RATE = 115_200
|
|
36
|
+
_READ_TIMEOUT_S = 0.1
|
|
37
|
+
_OPEN_SETTLE_S = 0.05
|
|
38
|
+
_START_BUSY_S = 0.35 # the PPK2 holds commands for 0.31 s after AVERAGE_START
|
|
39
|
+
_STREAM_BYTES_PER_S = 400_000 # 100,000 samples of 4 bytes
|
|
40
|
+
_CAUGHT_UP_BYTES = 4_000 # within 10 ms of the stream: caught up
|
|
41
|
+
_CATCH_UP_CAP_S = 1.5 # how long to try, at most
|
|
42
|
+
_METADATA_READ_TIMEOUT_S = 2.5
|
|
43
|
+
_QUIET_S = 0.05 # no byte for this long: the stream has ended
|
|
44
|
+
_QUIET_CAP_S = 0.5 # how long to wait for that, at most
|
|
45
|
+
_HANDSHAKE_ATTEMPTS = 3
|
|
46
|
+
_OPEN_ATTEMPTS = 3
|
|
47
|
+
|
|
48
|
+
#: Lowest ``REGULATOR_SET`` value the firmware accepts, in millivolts.
|
|
49
|
+
#: Below it the on-board LDO does not regulate cleanly.
|
|
50
|
+
VOLTAGE_LIMIT_HARDWARE_MIN_MV: int = 800
|
|
51
|
+
|
|
52
|
+
#: Highest voltage the on-board regulator can supply, in millivolts: a
|
|
53
|
+
#: hard ceiling. ``Session.set_voltage_limit`` can only lower it.
|
|
54
|
+
VOLTAGE_LIMIT_HARDWARE_MAX_MV: int = 5000
|
|
55
|
+
|
|
56
|
+
#: The user gains Nordic's app accepts, per range.
|
|
57
|
+
USER_GAIN_MIN: float = 0.9
|
|
58
|
+
USER_GAIN_MAX: float = 1.1
|
|
59
|
+
|
|
60
|
+
|
|
61
|
+
class SessionError(Exception):
|
|
62
|
+
"""Base class for session lifecycle failures."""
|
|
63
|
+
|
|
64
|
+
|
|
65
|
+
class SerialIOError(SessionError):
|
|
66
|
+
"""Underlying serial I/O failed."""
|
|
67
|
+
|
|
68
|
+
|
|
69
|
+
class HandshakeFailed(SessionError):
|
|
70
|
+
"""The metadata handshake ran out of attempts.
|
|
71
|
+
|
|
72
|
+
``attempts`` is how many were made; ``last`` describes the final
|
|
73
|
+
failure (write error, no END, parse error).
|
|
74
|
+
"""
|
|
75
|
+
|
|
76
|
+
def __init__(self, attempts: int, last: str) -> None:
|
|
77
|
+
super().__init__(f"metadata recovery failed after {attempts} attempts; last: {last}")
|
|
78
|
+
self.attempts = attempts
|
|
79
|
+
self.last = last
|
|
80
|
+
|
|
81
|
+
|
|
82
|
+
class Mode(IntEnum):
|
|
83
|
+
"""PPK2 measurement mode; the value is the wire byte.
|
|
84
|
+
|
|
85
|
+
``AMPERE`` is the Ampere meter mode of Nordic's app: the DUT has its
|
|
86
|
+
own supply and the PPK2 sits in series. ``SOURCE`` is its Source
|
|
87
|
+
meter mode: the PPK2 supplies the DUT.
|
|
88
|
+
"""
|
|
89
|
+
|
|
90
|
+
AMPERE = 0x01
|
|
91
|
+
SOURCE = 0x02
|
|
92
|
+
|
|
93
|
+
|
|
94
|
+
class Session:
|
|
95
|
+
"""An open PPK2 session: the serial port plus the device's calibration.
|
|
96
|
+
|
|
97
|
+
Use it as a context manager (``with Session.open(port) as s:``) so
|
|
98
|
+
the teardown runs even on an exception.
|
|
99
|
+
|
|
100
|
+
One ``Session`` per thread: the serial port underneath is not safe
|
|
101
|
+
to share.
|
|
102
|
+
"""
|
|
103
|
+
|
|
104
|
+
def __init__(self, port: serial.Serial, coeffs: CalibrationCoefficients) -> None:
|
|
105
|
+
"""Wrap an already-open port and its parsed calibration.
|
|
106
|
+
|
|
107
|
+
Prefer ``Session.open``, which opens the port and runs the
|
|
108
|
+
handshake.
|
|
109
|
+
|
|
110
|
+
The supply voltage starts at ``coeffs.vdd_mv``, the value the
|
|
111
|
+
firmware reported and keeps across host disconnects: a PPK2
|
|
112
|
+
left at 1,800 mV starts the next session at 1,800 mV until
|
|
113
|
+
``set_source_voltage`` says otherwise. Same as Nordic's app.
|
|
114
|
+
"""
|
|
115
|
+
self._port = port
|
|
116
|
+
if not all(USER_GAIN_MIN <= g <= USER_GAIN_MAX for g in coeffs.ug):
|
|
117
|
+
# As Nordic's app does when it connects.
|
|
118
|
+
warnings.warn(
|
|
119
|
+
f"the PPK2 reports a user gain outside {USER_GAIN_MIN} to "
|
|
120
|
+
f"{USER_GAIN_MAX} ({coeffs.ug}); all five are taken as 1.0",
|
|
121
|
+
RuntimeWarning,
|
|
122
|
+
stacklevel=2,
|
|
123
|
+
)
|
|
124
|
+
coeffs = replace(coeffs, ug=(1.0, 1.0, 1.0, 1.0, 1.0))
|
|
125
|
+
self._coeffs = coeffs
|
|
126
|
+
self._vdd_mv = coeffs.vdd_mv
|
|
127
|
+
self._spike_filter = SpikeFilter()
|
|
128
|
+
self._voltage_limit_mv = VOLTAGE_LIMIT_HARDWARE_MAX_MV
|
|
129
|
+
self._closed = False
|
|
130
|
+
self._measuring = False
|
|
131
|
+
self._stream_started_at = 0.0
|
|
132
|
+
self._stream_bytes = 0 # read since start_measuring
|
|
133
|
+
|
|
134
|
+
# ── Construction ───────────────────────────────────────────────────
|
|
135
|
+
|
|
136
|
+
@classmethod
|
|
137
|
+
def open(cls, device: str) -> "Session":
|
|
138
|
+
"""Open ``device`` and run the metadata handshake.
|
|
139
|
+
|
|
140
|
+
Up to 3 attempts, 0.5 s then 1.0 s apart. The retries are for
|
|
141
|
+
a port left stuck by another program's capture (seen on
|
|
142
|
+
macOS), above all one that sent ``RESET`` on close.
|
|
143
|
+
"""
|
|
144
|
+
last_err: SessionError = SerialIOError("open: never attempted")
|
|
145
|
+
for attempt in range(_OPEN_ATTEMPTS):
|
|
146
|
+
try:
|
|
147
|
+
port, coeffs = cls._try_open_once(device)
|
|
148
|
+
except SessionError as exc:
|
|
149
|
+
last_err = exc
|
|
150
|
+
if attempt == _OPEN_ATTEMPTS - 1:
|
|
151
|
+
break
|
|
152
|
+
# 0.5 s then 1.0 s: 1.5 s total backoff across 3 attempts.
|
|
153
|
+
sleep(0.5 * (1 << attempt))
|
|
154
|
+
continue
|
|
155
|
+
else:
|
|
156
|
+
return cls(port=port, coeffs=coeffs)
|
|
157
|
+
raise last_err
|
|
158
|
+
|
|
159
|
+
@staticmethod
|
|
160
|
+
def _try_open_once(device: str) -> tuple[serial.Serial, CalibrationCoefficients]:
|
|
161
|
+
"""One open + handshake attempt."""
|
|
162
|
+
try:
|
|
163
|
+
# exclusive=True: the open fails while another program
|
|
164
|
+
# holds the port, and others fail while this session lives.
|
|
165
|
+
port = serial.Serial(
|
|
166
|
+
device,
|
|
167
|
+
baudrate=_BAUD_RATE,
|
|
168
|
+
timeout=_READ_TIMEOUT_S,
|
|
169
|
+
write_timeout=_READ_TIMEOUT_S,
|
|
170
|
+
exclusive=True,
|
|
171
|
+
)
|
|
172
|
+
except serial.SerialException as exc:
|
|
173
|
+
raise SerialIOError(f"serial open: {exc}") from exc
|
|
174
|
+
sleep(_OPEN_SETTLE_S)
|
|
175
|
+
try:
|
|
176
|
+
_empty_serial(port)
|
|
177
|
+
coeffs = _recover_and_negotiate(port)
|
|
178
|
+
except BaseException:
|
|
179
|
+
# Left open, the port would keep its lock and fail the next attempt.
|
|
180
|
+
with suppress(Exception):
|
|
181
|
+
port.close()
|
|
182
|
+
raise
|
|
183
|
+
return port, coeffs
|
|
184
|
+
|
|
185
|
+
# ── Context manager protocol ───────────────────────────────────────
|
|
186
|
+
|
|
187
|
+
def __enter__(self) -> "Session":
|
|
188
|
+
return self
|
|
189
|
+
|
|
190
|
+
def __exit__(self, *_args: object) -> None:
|
|
191
|
+
self.close()
|
|
192
|
+
|
|
193
|
+
def close(self) -> None:
|
|
194
|
+
"""Stop the stream, cut power to the DUT, wait for the stream to end, close the port.
|
|
195
|
+
|
|
196
|
+
Idempotent; errors are swallowed. No ``RESET`` is sent: it makes the
|
|
197
|
+
PPK2 leave USB and come back, which takes 200 to 500 ms and can
|
|
198
|
+
block the next session.
|
|
199
|
+
|
|
200
|
+
The port is not closed while samples still arrive. Closed right
|
|
201
|
+
after ``AVERAGE_STOP``, the PPK2 can miss the command and keep
|
|
202
|
+
streaming, and what was in flight goes to whoever opens the port
|
|
203
|
+
next: a client that asks for the metadata first, like Nordic's
|
|
204
|
+
own tools, then gets no usable answer.
|
|
205
|
+
|
|
206
|
+
DUT power does not outlive the session: the PPK2 cuts it by itself
|
|
207
|
+
when the port closes (it follows the DTR line), so this holds even
|
|
208
|
+
when the process is killed and this method never runs.
|
|
209
|
+
"""
|
|
210
|
+
if self._closed:
|
|
211
|
+
return
|
|
212
|
+
self._closed = True
|
|
213
|
+
with suppress(serial.SerialException):
|
|
214
|
+
self._port.write(bytes([Opcode.AVERAGE_STOP.byte()]))
|
|
215
|
+
with suppress(serial.SerialException):
|
|
216
|
+
self._port.write(bytes([Opcode.DEVICE_RUNNING_SET.byte(), 0x00]))
|
|
217
|
+
self._wait_for_quiet()
|
|
218
|
+
with suppress(serial.SerialException):
|
|
219
|
+
self._port.close()
|
|
220
|
+
|
|
221
|
+
# ── Accessors ──────────────────────────────────────────────────────
|
|
222
|
+
|
|
223
|
+
def coefficients(self) -> CalibrationCoefficients:
|
|
224
|
+
"""Per-device calibration read at session open."""
|
|
225
|
+
return self._coeffs
|
|
226
|
+
|
|
227
|
+
# ── Configuration ──────────────────────────────────────────────────
|
|
228
|
+
|
|
229
|
+
def set_mode(self, mode: Mode) -> None:
|
|
230
|
+
"""Select the measurement mode.
|
|
231
|
+
|
|
232
|
+
Call it before ``start_measuring``. On the PPK2 tested, a
|
|
233
|
+
change sent during a stream was applied too; nothing here
|
|
234
|
+
relies on that.
|
|
235
|
+
"""
|
|
236
|
+
self._write(bytes([Opcode.SET_POWER_MODE.byte(), int(mode)]))
|
|
237
|
+
|
|
238
|
+
def set_source_voltage(self, mv: int) -> None:
|
|
239
|
+
"""Set the supply voltage in millivolts.
|
|
240
|
+
|
|
241
|
+
In Source meter mode this is what the PPK2 outputs. In Ampere
|
|
242
|
+
meter mode the regulator is inactive, but the value still feeds
|
|
243
|
+
the calibration: set it to the DUT's real supply voltage.
|
|
244
|
+
|
|
245
|
+
Values outside 800 to 5,000 mV are brought back to the nearest
|
|
246
|
+
limit; the firmware would ignore them.
|
|
247
|
+
|
|
248
|
+
Raises:
|
|
249
|
+
ValueError: If ``mv`` exceeds the cap set with
|
|
250
|
+
``set_voltage_limit``.
|
|
251
|
+
SerialIOError: If the serial write fails.
|
|
252
|
+
"""
|
|
253
|
+
clamped = max(VOLTAGE_LIMIT_HARDWARE_MIN_MV, min(VOLTAGE_LIMIT_HARDWARE_MAX_MV, mv))
|
|
254
|
+
if clamped > self._voltage_limit_mv:
|
|
255
|
+
raise ValueError(
|
|
256
|
+
f"requested {mv} mV exceeds voltage limit "
|
|
257
|
+
f"{self._voltage_limit_mv} mV: call set_voltage_limit "
|
|
258
|
+
f"first if you want to raise the ceiling"
|
|
259
|
+
)
|
|
260
|
+
wire = bytes(
|
|
261
|
+
[
|
|
262
|
+
Opcode.REGULATOR_SET.byte(),
|
|
263
|
+
(clamped >> 8) & 0xFF,
|
|
264
|
+
clamped & 0xFF,
|
|
265
|
+
]
|
|
266
|
+
)
|
|
267
|
+
self._write(wire)
|
|
268
|
+
self._vdd_mv = clamped
|
|
269
|
+
|
|
270
|
+
def set_voltage_limit(self, mv: int) -> None:
|
|
271
|
+
"""Cap what ``set_source_voltage`` will accept, in millivolts.
|
|
272
|
+
|
|
273
|
+
A host-side guard against typing a DUT-damaging voltage, like
|
|
274
|
+
the app's voltage limit ("Set max supply voltage to"). The cap
|
|
275
|
+
is itself kept within 800 to 5,000 mV, and it does not change a
|
|
276
|
+
supply voltage already above it.
|
|
277
|
+
|
|
278
|
+
Raises:
|
|
279
|
+
RuntimeError: If called while a stream runs, between
|
|
280
|
+
``start_measuring`` and ``stop_measuring``.
|
|
281
|
+
"""
|
|
282
|
+
if self._measuring:
|
|
283
|
+
raise RuntimeError("set_voltage_limit must be called before start_measuring()")
|
|
284
|
+
self._voltage_limit_mv = max(
|
|
285
|
+
VOLTAGE_LIMIT_HARDWARE_MIN_MV,
|
|
286
|
+
min(VOLTAGE_LIMIT_HARDWARE_MAX_MV, mv),
|
|
287
|
+
)
|
|
288
|
+
|
|
289
|
+
def voltage_limit(self) -> int:
|
|
290
|
+
"""The cap set by ``set_voltage_limit``, in millivolts."""
|
|
291
|
+
return self._voltage_limit_mv
|
|
292
|
+
|
|
293
|
+
# ── Stream control ─────────────────────────────────────────────────
|
|
294
|
+
|
|
295
|
+
def start_measuring(self) -> None:
|
|
296
|
+
"""Start the stream of samples, 100,000 per second."""
|
|
297
|
+
self._write(bytes([Opcode.AVERAGE_START.byte()]))
|
|
298
|
+
self._stream_started_at = monotonic()
|
|
299
|
+
self._stream_bytes = 0
|
|
300
|
+
self._measuring = True
|
|
301
|
+
|
|
302
|
+
def stop_measuring(self) -> None:
|
|
303
|
+
"""Send ``AVERAGE_STOP`` and read the stream out to its end.
|
|
304
|
+
|
|
305
|
+
Left unread, the end of the stream would lead the next one: a
|
|
306
|
+
few milliseconds of samples from before the stop. Safe to call
|
|
307
|
+
when no stream is active.
|
|
308
|
+
"""
|
|
309
|
+
self._write(bytes([Opcode.AVERAGE_STOP.byte()]))
|
|
310
|
+
self._wait_for_quiet()
|
|
311
|
+
self._measuring = False
|
|
312
|
+
|
|
313
|
+
# ── DUT power ──────────────────────────────────────────────────────
|
|
314
|
+
|
|
315
|
+
def power_on(self) -> None:
|
|
316
|
+
"""Switch power to the DUT on, as the app's "Enable power output" does.
|
|
317
|
+
|
|
318
|
+
The power comes up about 1 ms after the command. With a stream
|
|
319
|
+
running, the stream is first read until the host has caught up
|
|
320
|
+
with it, which takes until about 0.9 s after ``start_measuring``.
|
|
321
|
+
The samples read after this call are then from the switch on, to
|
|
322
|
+
within about 10 ms, so a capture that follows has the boot in it
|
|
323
|
+
(the protocol page, Known caveats).
|
|
324
|
+
"""
|
|
325
|
+
self._catch_up()
|
|
326
|
+
self._write(bytes([Opcode.DEVICE_RUNNING_SET.byte(), 0x01]))
|
|
327
|
+
|
|
328
|
+
def power_off(self) -> None:
|
|
329
|
+
"""Switch power to the DUT off. Idempotent."""
|
|
330
|
+
self._write(bytes([Opcode.DEVICE_RUNNING_SET.byte(), 0x00]))
|
|
331
|
+
|
|
332
|
+
def drop_pending_backlog(self) -> int:
|
|
333
|
+
"""Discard what the OS reports as waiting; return the byte count.
|
|
334
|
+
|
|
335
|
+
One read, not a loop: a running stream never goes empty, so
|
|
336
|
+
draining until empty would hang. It does not bring the reads up
|
|
337
|
+
to the present: on macOS ``in_waiting`` reports about 1 kB while
|
|
338
|
+
some 40 kB are queued (the protocol page, Known caveats).
|
|
339
|
+
|
|
340
|
+
Raises:
|
|
341
|
+
SerialIOError: If the serial read fails.
|
|
342
|
+
"""
|
|
343
|
+
try:
|
|
344
|
+
waiting = self._port.in_waiting
|
|
345
|
+
if waiting:
|
|
346
|
+
self._stream_bytes += len(self._port.read(waiting))
|
|
347
|
+
except serial.SerialException as exc:
|
|
348
|
+
raise SerialIOError(f"serial read: {exc}") from exc
|
|
349
|
+
return waiting
|
|
350
|
+
|
|
351
|
+
# ── User gain override ─────────────────────────────────────────────
|
|
352
|
+
|
|
353
|
+
def set_user_gain(self, range_idx: int, gain: float) -> None:
|
|
354
|
+
"""Override the user gain of one range for this session.
|
|
355
|
+
|
|
356
|
+
Host-side only: the calibration used by the next ``capture`` is
|
|
357
|
+
rebuilt with the new gain and nothing is sent. Current firmware
|
|
358
|
+
ignores ``SET_USER_GAINS``, and Nordic's app applies the gain
|
|
359
|
+
host-side too. The override is gone at ``close``.
|
|
360
|
+
|
|
361
|
+
Args:
|
|
362
|
+
range_idx: Which of the five measurement ranges, 0 to 4. The
|
|
363
|
+
app numbers them 1 to 5.
|
|
364
|
+
gain: The gain, from 0.9 to 1.1 as in the app.
|
|
365
|
+
|
|
366
|
+
Raises:
|
|
367
|
+
ValueError: If ``range_idx`` is not 0 to 4, or ``gain`` is not
|
|
368
|
+
from 0.9 to 1.1.
|
|
369
|
+
RuntimeError: If called while a stream runs, between
|
|
370
|
+
``start_measuring`` and ``stop_measuring``.
|
|
371
|
+
"""
|
|
372
|
+
if self._measuring:
|
|
373
|
+
raise RuntimeError(
|
|
374
|
+
"set_user_gain must be called before start_measuring(); "
|
|
375
|
+
"the active capture's StreamParser uses the coefficients "
|
|
376
|
+
"captured at init time."
|
|
377
|
+
)
|
|
378
|
+
if not 0 <= range_idx <= 4:
|
|
379
|
+
raise ValueError(f"range_idx must be 0 to 4, got {range_idx}")
|
|
380
|
+
if not USER_GAIN_MIN <= gain <= USER_GAIN_MAX:
|
|
381
|
+
raise ValueError(f"gain must be from {USER_GAIN_MIN} to {USER_GAIN_MAX}, got {gain}")
|
|
382
|
+
old_ug = self._coeffs.ug
|
|
383
|
+
new_ug: RangeArray = (
|
|
384
|
+
gain if range_idx == 0 else old_ug[0],
|
|
385
|
+
gain if range_idx == 1 else old_ug[1],
|
|
386
|
+
gain if range_idx == 2 else old_ug[2],
|
|
387
|
+
gain if range_idx == 3 else old_ug[3],
|
|
388
|
+
gain if range_idx == 4 else old_ug[4],
|
|
389
|
+
)
|
|
390
|
+
self._coeffs = replace(self._coeffs, ug=new_ug)
|
|
391
|
+
|
|
392
|
+
# ── Spike-filter settings ──────────────────────────────────────────
|
|
393
|
+
|
|
394
|
+
def set_spike_filter(
|
|
395
|
+
self,
|
|
396
|
+
*,
|
|
397
|
+
samples: int | None = None,
|
|
398
|
+
alpha: float | None = None,
|
|
399
|
+
alpha5: float | None = None,
|
|
400
|
+
) -> None:
|
|
401
|
+
"""Change settings of the spike filter; those not passed keep their value.
|
|
402
|
+
|
|
403
|
+
Host-side, like Nordic's app: the next ``capture`` builds its
|
|
404
|
+
parser with these. See ``SpikeFilter`` for what each setting does
|
|
405
|
+
and its limits. The change is gone at ``close``.
|
|
406
|
+
|
|
407
|
+
Raises:
|
|
408
|
+
ValueError: If a setting is out of range.
|
|
409
|
+
RuntimeError: If called while a stream runs, between
|
|
410
|
+
``start_measuring`` and ``stop_measuring``.
|
|
411
|
+
"""
|
|
412
|
+
if self._measuring:
|
|
413
|
+
raise RuntimeError(
|
|
414
|
+
"set_spike_filter must be called before start_measuring(); "
|
|
415
|
+
"the active capture's StreamParser was built with the "
|
|
416
|
+
"previous filter and can't switch mid-stream."
|
|
417
|
+
)
|
|
418
|
+
current = self._spike_filter
|
|
419
|
+
self._spike_filter = SpikeFilter(
|
|
420
|
+
samples=current.samples if samples is None else samples,
|
|
421
|
+
alpha=current.alpha if alpha is None else alpha,
|
|
422
|
+
alpha5=current.alpha5 if alpha5 is None else alpha5,
|
|
423
|
+
)
|
|
424
|
+
|
|
425
|
+
def spike_filter(self) -> SpikeFilter:
|
|
426
|
+
"""The spike-filter settings the next ``capture`` will use."""
|
|
427
|
+
return self._spike_filter
|
|
428
|
+
|
|
429
|
+
# ── Capture loop ───────────────────────────────────────────────────
|
|
430
|
+
|
|
431
|
+
def capture(
|
|
432
|
+
self,
|
|
433
|
+
emit: Callable[[Sample], bool],
|
|
434
|
+
on_dataloss: Callable[[int], None] | None = None,
|
|
435
|
+
keep_going: Callable[[], bool] | None = None,
|
|
436
|
+
) -> None:
|
|
437
|
+
"""Read the stream and call ``emit`` per sample until it returns ``False``.
|
|
438
|
+
|
|
439
|
+
Args:
|
|
440
|
+
emit: Called with each ``Sample``; return ``False`` to stop.
|
|
441
|
+
It is not called again after that.
|
|
442
|
+
on_dataloss: Called with the running total of lost samples
|
|
443
|
+
whenever a read adds to it (at most once per read).
|
|
444
|
+
keep_going: Called after every read; return ``False`` to
|
|
445
|
+
stop. Without it, a PPK2 that sends nothing, or nothing
|
|
446
|
+
that decodes to a sample, keeps ``capture`` waiting for
|
|
447
|
+
ever, since ``emit`` is never called.
|
|
448
|
+
"""
|
|
449
|
+
parser = StreamParser(self._coeffs, self._vdd_mv, self._spike_filter)
|
|
450
|
+
scratch = bytearray(4096)
|
|
451
|
+
stop = False
|
|
452
|
+
|
|
453
|
+
def collect(sample: Sample) -> None:
|
|
454
|
+
nonlocal stop
|
|
455
|
+
# The rest of a read is dropped once emit has said stop.
|
|
456
|
+
if not stop and not emit(sample):
|
|
457
|
+
stop = True
|
|
458
|
+
|
|
459
|
+
while not stop:
|
|
460
|
+
n = self._read_into(scratch)
|
|
461
|
+
# Asked after every read: bytes that hold no sample must not
|
|
462
|
+
# keep a capture going either.
|
|
463
|
+
if keep_going is not None and not keep_going():
|
|
464
|
+
return
|
|
465
|
+
if n == 0:
|
|
466
|
+
continue
|
|
467
|
+
before = parser.dataloss_total
|
|
468
|
+
parser.push_bytes(bytes(scratch[:n]), collect)
|
|
469
|
+
if on_dataloss is not None and parser.dataloss_total > before:
|
|
470
|
+
on_dataloss(parser.dataloss_total)
|
|
471
|
+
|
|
472
|
+
# ── Internals ──────────────────────────────────────────────────────
|
|
473
|
+
|
|
474
|
+
def _catch_up(self) -> None:
|
|
475
|
+
"""Read and discard until the reads have caught up with the stream.
|
|
476
|
+
|
|
477
|
+
For 0.31 s after ``AVERAGE_START`` the PPK2 sends slowly and
|
|
478
|
+
holds any command it receives, and the host is level with the
|
|
479
|
+
stream only after about 0.9 s (measured on macOS). Caught up
|
|
480
|
+
means: past that first stretch, and as many bytes read as the
|
|
481
|
+
PPK2 has produced since ``start_measuring``, to within 10 ms.
|
|
482
|
+
Gives up after ``_CATCH_UP_CAP_S``. Does nothing without a
|
|
483
|
+
stream.
|
|
484
|
+
"""
|
|
485
|
+
if not self._measuring:
|
|
486
|
+
return
|
|
487
|
+
deadline = monotonic() + _CATCH_UP_CAP_S
|
|
488
|
+
scratch = bytearray(4096)
|
|
489
|
+
while (now := monotonic()) < deadline:
|
|
490
|
+
elapsed = now - self._stream_started_at
|
|
491
|
+
behind = elapsed * _STREAM_BYTES_PER_S - self._stream_bytes
|
|
492
|
+
if elapsed >= _START_BUSY_S and behind <= _CAUGHT_UP_BYTES:
|
|
493
|
+
return
|
|
494
|
+
self._read_into(scratch)
|
|
495
|
+
|
|
496
|
+
def _wait_for_quiet(self) -> None:
|
|
497
|
+
"""Read and discard until no byte arrives for ``_QUIET_S``.
|
|
498
|
+
|
|
499
|
+
Gives up after ``_QUIET_CAP_S``. Best effort: the port may
|
|
500
|
+
already be gone.
|
|
501
|
+
"""
|
|
502
|
+
deadline = monotonic() + _QUIET_CAP_S
|
|
503
|
+
with suppress(Exception):
|
|
504
|
+
read_timeout = self._port.timeout
|
|
505
|
+
self._port.timeout = _QUIET_S
|
|
506
|
+
try:
|
|
507
|
+
while monotonic() < deadline and self._port.read(4096):
|
|
508
|
+
pass
|
|
509
|
+
finally:
|
|
510
|
+
self._port.timeout = read_timeout
|
|
511
|
+
|
|
512
|
+
def _write(self, payload: bytes) -> None:
|
|
513
|
+
try:
|
|
514
|
+
self._port.write(payload)
|
|
515
|
+
except serial.SerialException as exc:
|
|
516
|
+
raise SerialIOError(f"serial write: {exc}") from exc
|
|
517
|
+
|
|
518
|
+
def _read_into(self, buf: bytearray) -> int:
|
|
519
|
+
"""Read up to ``len(buf)`` bytes into ``buf``; return the count, 0 on timeout."""
|
|
520
|
+
try:
|
|
521
|
+
chunk = self._port.read(len(buf))
|
|
522
|
+
except serial.SerialException as exc:
|
|
523
|
+
raise SerialIOError(f"serial read: {exc}") from exc
|
|
524
|
+
n = len(chunk)
|
|
525
|
+
if n:
|
|
526
|
+
buf[:n] = chunk
|
|
527
|
+
self._stream_bytes += n
|
|
528
|
+
return n
|
|
529
|
+
|
|
530
|
+
|
|
531
|
+
# ─── module-private helpers ────────────────────────────────────────────
|
|
532
|
+
|
|
533
|
+
|
|
534
|
+
def flush_input(port: serial.Serial) -> None:
|
|
535
|
+
"""Discard buffered input, best effort.
|
|
536
|
+
|
|
537
|
+
On a port that has just dropped off USB (the device re-enumerates
|
|
538
|
+
after a ``RESET``), pyserial lets a bare ``termios.error`` through:
|
|
539
|
+
neither ``SerialException`` nor ``OSError``. The next write or read
|
|
540
|
+
reports the dead port properly.
|
|
541
|
+
"""
|
|
542
|
+
with suppress(Exception):
|
|
543
|
+
port.reset_input_buffer()
|
|
544
|
+
|
|
545
|
+
|
|
546
|
+
def _empty_serial(port: serial.Serial) -> None:
|
|
547
|
+
"""Drain whatever the firmware was still emitting, up to ~1 s."""
|
|
548
|
+
deadline = monotonic() + 1.0
|
|
549
|
+
while monotonic() < deadline:
|
|
550
|
+
try:
|
|
551
|
+
waiting = port.in_waiting
|
|
552
|
+
except (serial.SerialException, OSError):
|
|
553
|
+
return
|
|
554
|
+
if waiting == 0:
|
|
555
|
+
return
|
|
556
|
+
try:
|
|
557
|
+
port.read(waiting)
|
|
558
|
+
except serial.SerialException:
|
|
559
|
+
return
|
|
560
|
+
|
|
561
|
+
|
|
562
|
+
class BytesReader(Protocol):
|
|
563
|
+
"""Anything with ``read(n) -> bytes``: pyserial's ``Serial``, or a test fake."""
|
|
564
|
+
|
|
565
|
+
def read(self, n: int, /) -> bytes:
|
|
566
|
+
"""Read up to ``n`` bytes; return ``b""`` if none are ready."""
|
|
567
|
+
...
|
|
568
|
+
|
|
569
|
+
|
|
570
|
+
def read_until_end(reader: BytesReader, total_timeout_s: float) -> bytes:
|
|
571
|
+
"""Read until the data contains ``b"END"``, or raise ``TimeoutError``.
|
|
572
|
+
|
|
573
|
+
The metadata response can arrive split across several reads.
|
|
574
|
+
"""
|
|
575
|
+
deadline = monotonic() + total_timeout_s
|
|
576
|
+
buf = bytearray()
|
|
577
|
+
|
|
578
|
+
while monotonic() < deadline:
|
|
579
|
+
chunk = reader.read(512)
|
|
580
|
+
if not chunk:
|
|
581
|
+
sleep(0.02)
|
|
582
|
+
continue
|
|
583
|
+
buf.extend(chunk)
|
|
584
|
+
if b"END" in buf:
|
|
585
|
+
return bytes(buf)
|
|
586
|
+
|
|
587
|
+
raise TimeoutError(f"no END within {total_timeout_s}s; buffered {len(buf)} bytes")
|
|
588
|
+
|
|
589
|
+
|
|
590
|
+
def _recover_and_negotiate(port: serial.Serial) -> CalibrationCoefficients:
|
|
591
|
+
"""Stop any stream, reset on retries, read and parse the metadata.
|
|
592
|
+
|
|
593
|
+
Up to 3 attempts. A failed write is recorded as the failure instead
|
|
594
|
+
of being skipped: on a port that is stuck every write fails,
|
|
595
|
+
and reporting a later parse failure would hide the real cause.
|
|
596
|
+
"""
|
|
597
|
+
last_failure = "(no attempts made)"
|
|
598
|
+
|
|
599
|
+
for attempt in range(_HANDSHAKE_ATTEMPTS):
|
|
600
|
+
# In case a stream was left running.
|
|
601
|
+
try:
|
|
602
|
+
port.write(bytes([Opcode.AVERAGE_STOP.byte()]))
|
|
603
|
+
except serial.SerialException as exc:
|
|
604
|
+
last_failure = f"write AVERAGE_STOP: {exc}"
|
|
605
|
+
continue
|
|
606
|
+
sleep(0.1)
|
|
607
|
+
|
|
608
|
+
# RESET on retries only: it makes the PPK2 drop off USB.
|
|
609
|
+
if attempt > 0:
|
|
610
|
+
try:
|
|
611
|
+
port.write(bytes([Opcode.RESET.byte()]))
|
|
612
|
+
except serial.SerialException as exc:
|
|
613
|
+
last_failure = f"write RESET: {exc}"
|
|
614
|
+
continue
|
|
615
|
+
sleep(0.3)
|
|
616
|
+
|
|
617
|
+
# Discard what was still arriving.
|
|
618
|
+
flush_input(port)
|
|
619
|
+
_empty_serial(port)
|
|
620
|
+
|
|
621
|
+
try:
|
|
622
|
+
port.write(bytes([Opcode.GET_METADATA.byte()]))
|
|
623
|
+
except serial.SerialException as exc:
|
|
624
|
+
last_failure = f"write GET_METADATA: {exc}"
|
|
625
|
+
continue
|
|
626
|
+
|
|
627
|
+
try:
|
|
628
|
+
buf = read_until_end(port, _METADATA_READ_TIMEOUT_S)
|
|
629
|
+
except (TimeoutError, OSError) as exc:
|
|
630
|
+
last_failure = f"read metadata: {exc}"
|
|
631
|
+
continue
|
|
632
|
+
|
|
633
|
+
try:
|
|
634
|
+
return parse_metadata(buf)
|
|
635
|
+
except MetadataError as exc:
|
|
636
|
+
last_failure = f"parse_metadata: {exc!r}"
|
|
637
|
+
continue
|
|
638
|
+
|
|
639
|
+
raise HandshakeFailed(_HANDSHAKE_ATTEMPTS, last_failure)
|
|
@@ -0,0 +1,51 @@
|
|
|
1
|
+
"""Pure protocol primitives: opcodes, metadata parser, sample decoder, stream.
|
|
2
|
+
|
|
3
|
+
Stdlib-only; no I/O. The top-level ``ppk2`` package re-exports the
|
|
4
|
+
items you'd typically import from here.
|
|
5
|
+
"""
|
|
6
|
+
|
|
7
|
+
from ppk2.protocol.calibration import current_micro_amps
|
|
8
|
+
from ppk2.protocol.metadata import (
|
|
9
|
+
NUM_RANGES,
|
|
10
|
+
CalibrationCoefficients,
|
|
11
|
+
InvalidValue,
|
|
12
|
+
MetadataError,
|
|
13
|
+
MissingEnd,
|
|
14
|
+
MissingField,
|
|
15
|
+
RangeArray,
|
|
16
|
+
parse_metadata,
|
|
17
|
+
)
|
|
18
|
+
from ppk2.protocol.opcode import Opcode
|
|
19
|
+
from ppk2.protocol.sample import RawSample, decode_sample, decode_sample_bytes
|
|
20
|
+
from ppk2.protocol.stream import (
|
|
21
|
+
DEFAULT_SPIKE_FILTER_ALPHA,
|
|
22
|
+
DEFAULT_SPIKE_FILTER_ALPHA5,
|
|
23
|
+
DEFAULT_SPIKE_FILTER_SAMPLES,
|
|
24
|
+
MAX_BUFFERED_CORRUPTED,
|
|
25
|
+
Sample,
|
|
26
|
+
SpikeFilter,
|
|
27
|
+
StreamParser,
|
|
28
|
+
)
|
|
29
|
+
|
|
30
|
+
__all__ = [
|
|
31
|
+
"DEFAULT_SPIKE_FILTER_ALPHA",
|
|
32
|
+
"DEFAULT_SPIKE_FILTER_ALPHA5",
|
|
33
|
+
"DEFAULT_SPIKE_FILTER_SAMPLES",
|
|
34
|
+
"MAX_BUFFERED_CORRUPTED",
|
|
35
|
+
"NUM_RANGES",
|
|
36
|
+
"CalibrationCoefficients",
|
|
37
|
+
"InvalidValue",
|
|
38
|
+
"MetadataError",
|
|
39
|
+
"MissingEnd",
|
|
40
|
+
"MissingField",
|
|
41
|
+
"Opcode",
|
|
42
|
+
"RangeArray",
|
|
43
|
+
"RawSample",
|
|
44
|
+
"Sample",
|
|
45
|
+
"SpikeFilter",
|
|
46
|
+
"StreamParser",
|
|
47
|
+
"current_micro_amps",
|
|
48
|
+
"decode_sample",
|
|
49
|
+
"decode_sample_bytes",
|
|
50
|
+
"parse_metadata",
|
|
51
|
+
]
|