@enyo-energy/sunspec-sdk 0.0.104 → 1.0.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +90 -0
- package/dist/cjs/sunspec-battery-schedule-handler.cjs +76 -28
- package/dist/cjs/sunspec-battery-schedule-handler.d.cts +33 -6
- package/dist/cjs/sunspec-devices.cjs +140 -29
- package/dist/cjs/sunspec-devices.d.cts +47 -3
- package/dist/cjs/sunspec-interfaces.cjs +9 -2
- package/dist/cjs/sunspec-interfaces.d.cts +73 -4
- package/dist/cjs/sunspec-modbus-client.cjs +280 -116
- package/dist/cjs/sunspec-modbus-client.d.cts +82 -5
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-battery-schedule-handler.d.ts +33 -6
- package/dist/sunspec-battery-schedule-handler.js +76 -28
- package/dist/sunspec-devices.d.ts +47 -3
- package/dist/sunspec-devices.js +139 -29
- package/dist/sunspec-interfaces.d.ts +73 -4
- package/dist/sunspec-interfaces.js +9 -2
- package/dist/sunspec-modbus-client.d.ts +82 -5
- package/dist/sunspec-modbus-client.js +277 -115
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
package/dist/sunspec-devices.js
CHANGED
|
@@ -231,7 +231,14 @@ export class BaseSunspecDevice {
|
|
|
231
231
|
`opened the socket but revalidation failed — retrying with backoff`);
|
|
232
232
|
return false;
|
|
233
233
|
}
|
|
234
|
-
|
|
234
|
+
// NOT reset() here — a reopened TCP socket is not yet a working device. On a peer
|
|
235
|
+
// that accepts connections but stops answering reads, resetting on the reconnect
|
|
236
|
+
// restarts the backoff schedule from its shortest phase on every cycle, so the
|
|
237
|
+
// schedule never advances past 10s no matter how long the outage runs: reconnect,
|
|
238
|
+
// read, time out, poison, mark offline, reconnect — indefinitely, at poll rate. The
|
|
239
|
+
// schedule is cleared instead by the first genuinely healthy read cycle (see
|
|
240
|
+
// markOfflineIfUnhealthy), which is the only evidence the link actually carries
|
|
241
|
+
// data. Until then `elapsed` keeps growing and the phases widen as intended.
|
|
235
242
|
this.consecutiveReconnectFailures = 0;
|
|
236
243
|
// Update appliance state to Connected
|
|
237
244
|
if (this.applianceId) {
|
|
@@ -247,7 +254,15 @@ export class BaseSunspecDevice {
|
|
|
247
254
|
await this.onConnectionFailure(this.consecutiveReconnectFailures);
|
|
248
255
|
}
|
|
249
256
|
catch (error) {
|
|
250
|
-
|
|
257
|
+
// Transition-only: the first throw of an outage is the news; every repeat while the
|
|
258
|
+
// peer stays down is the same news again, so it drops to debug.
|
|
259
|
+
const line = `${this.constructor.name} ${this.applianceId}: Reconnect attempt #${attempt} failed: ${error}`;
|
|
260
|
+
if (this.consecutiveReconnectFailures === 0) {
|
|
261
|
+
console.error(line);
|
|
262
|
+
}
|
|
263
|
+
else {
|
|
264
|
+
console.debug(line);
|
|
265
|
+
}
|
|
251
266
|
this.consecutiveReconnectFailures += 1;
|
|
252
267
|
await this.onConnectionFailure(this.consecutiveReconnectFailures);
|
|
253
268
|
}
|
|
@@ -315,6 +330,12 @@ export class BaseSunspecDevice {
|
|
|
315
330
|
*/
|
|
316
331
|
async markOfflineIfUnhealthy() {
|
|
317
332
|
if (this.sunspecClient.isHealthy(this.unitId)) {
|
|
333
|
+
// A completed read cycle on a healthy unit is the only proof the link carries data, so
|
|
334
|
+
// it — not a successful reconnect — is what clears the tiered retry schedule. See the
|
|
335
|
+
// note in tryReconnect(): resetting on reconnect alone pins a flapping device to the
|
|
336
|
+
// shortest retry phase forever.
|
|
337
|
+
this.retryManager.reset();
|
|
338
|
+
this.consecutiveReconnectFailures = 0;
|
|
318
339
|
return false;
|
|
319
340
|
}
|
|
320
341
|
console.warn(`${this.constructor.name} ${this.applianceId}: connection unhealthy after read cycle ` +
|
|
@@ -473,6 +494,7 @@ function finiteOrUndefined(value) {
|
|
|
473
494
|
export class SunspecInverter extends BaseSunspecDevice {
|
|
474
495
|
capabilities;
|
|
475
496
|
pvPowerSource;
|
|
497
|
+
metadataConfig;
|
|
476
498
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
477
499
|
static CONNECTION_FAULT_THRESHOLD = 3;
|
|
478
500
|
/**
|
|
@@ -519,10 +541,29 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
519
541
|
// only summed MPPT strings, or Inverter to use only the inverter total —
|
|
520
542
|
// e.g. for devices whose Model 160 strings are unreliable or whose AC
|
|
521
543
|
// includes non-PV sources (a hybrid's battery discharge).
|
|
522
|
-
pvPowerSource = SunspecPvPowerSource.Auto
|
|
544
|
+
pvPowerSource = SunspecPvPowerSource.Auto,
|
|
545
|
+
// Facts about the installation that no register carries (control policy, module peak power).
|
|
546
|
+
// Forwarded onto `appliance.inverter` on connect; see SunspecInverterMetadataConfig.
|
|
547
|
+
metadataConfig = {}) {
|
|
523
548
|
super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
|
|
524
549
|
this.capabilities = capabilities;
|
|
525
550
|
this.pvPowerSource = pvPowerSource;
|
|
551
|
+
this.metadataConfig = metadataConfig;
|
|
552
|
+
}
|
|
553
|
+
/**
|
|
554
|
+
* The consumer-supplied inverter facts, as a spreadable object that only contains the keys that
|
|
555
|
+
* were actually configured. Spreading `{ controlAllowed: undefined }` over an existing appliance
|
|
556
|
+
* would erase a value the host set elsewhere; omitting the key leaves it alone.
|
|
557
|
+
*/
|
|
558
|
+
configuredInverterMetadata() {
|
|
559
|
+
const configured = {};
|
|
560
|
+
if (this.metadataConfig.controlAllowed !== undefined) {
|
|
561
|
+
configured.controlAllowed = this.metadataConfig.controlAllowed;
|
|
562
|
+
}
|
|
563
|
+
if (this.metadataConfig.installedPeakPowerWp !== undefined) {
|
|
564
|
+
configured.installedPeakPowerWp = this.metadataConfig.installedPeakPowerWp;
|
|
565
|
+
}
|
|
566
|
+
return configured;
|
|
526
567
|
}
|
|
527
568
|
async connect() {
|
|
528
569
|
// Ensure Sunspec client is connected
|
|
@@ -556,7 +597,8 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
556
597
|
inverter: {
|
|
557
598
|
dcStrings: this.mapDcStringToApplianceMetadata(this.mapMPPTToStrings(mpptDataList)),
|
|
558
599
|
maxPvProductionW: inverterSettings?.WMax,
|
|
559
|
-
activeProductionLimitationW: activeProductionLimitationW
|
|
600
|
+
activeProductionLimitationW: activeProductionLimitationW,
|
|
601
|
+
...this.configuredInverterMetadata()
|
|
560
602
|
}
|
|
561
603
|
});
|
|
562
604
|
console.log(`Sunspec Inverter connected: ${this.networkDevice.hostname} (${this.applianceId})`);
|
|
@@ -583,7 +625,8 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
583
625
|
...existingAppliance?.inverter,
|
|
584
626
|
dcStrings: this.mapDcStringToApplianceMetadata(this.mapMPPTToStrings(mpptDataList)),
|
|
585
627
|
maxPvProductionW: inverterSettings?.WMax,
|
|
586
|
-
activeProductionLimitationW: activeProductionLimitationW
|
|
628
|
+
activeProductionLimitationW: activeProductionLimitationW,
|
|
629
|
+
...this.configuredInverterMetadata()
|
|
587
630
|
}
|
|
588
631
|
});
|
|
589
632
|
console.log(`Sunspec Inverter connected: ${this.networkDevice.hostname} (${this.applianceId})`);
|
|
@@ -1425,6 +1468,37 @@ export function filterFeaturesByCalibrationResult(detected, result, controllable
|
|
|
1425
1468
|
/**
|
|
1426
1469
|
* Sunspec Battery implementation
|
|
1427
1470
|
*/
|
|
1471
|
+
/**
|
|
1472
|
+
* Derive the storage mode from Model 124's StorCtl_Mod bitfield.
|
|
1473
|
+
*
|
|
1474
|
+
* The bits mark *which rate setpoint the device is enforcing* — bit 0 for
|
|
1475
|
+
* InWRte, bit 1 for OutWRte — not which direction is permitted. So no bit set
|
|
1476
|
+
* is the autonomous mode, and both bits set is the most externally controlled
|
|
1477
|
+
* state there is, which is the opposite of what the naming suggests. Reading
|
|
1478
|
+
* them the other way round meant a battery running its own logic reported
|
|
1479
|
+
* `holding`, a fully clamped one reported `auto`, and no appliance could ever
|
|
1480
|
+
* report that it had been handed back to itself.
|
|
1481
|
+
*
|
|
1482
|
+
* @param controls - Model 124 control registers, or null when unreadable.
|
|
1483
|
+
* @returns The mode, or null when StorCtl_Mod could not be read.
|
|
1484
|
+
*/
|
|
1485
|
+
export function deriveStorageMode(controls) {
|
|
1486
|
+
if (!controls || controls.storCtlMod === undefined) {
|
|
1487
|
+
return null;
|
|
1488
|
+
}
|
|
1489
|
+
const chargeLimited = (controls.storCtlMod & 0x0001) !== 0;
|
|
1490
|
+
const dischargeLimited = (controls.storCtlMod & 0x0002) !== 0;
|
|
1491
|
+
if (!chargeLimited && !dischargeLimited) {
|
|
1492
|
+
return SunspecStorageMode.AUTO;
|
|
1493
|
+
}
|
|
1494
|
+
// Both directions clamped to zero — the battery is parked, not idling.
|
|
1495
|
+
if (chargeLimited && dischargeLimited && controls.inWRte === 0 && controls.outWRte === 0) {
|
|
1496
|
+
return SunspecStorageMode.HOLDING;
|
|
1497
|
+
}
|
|
1498
|
+
return dischargeLimited && !chargeLimited
|
|
1499
|
+
? SunspecStorageMode.DISCHARGE
|
|
1500
|
+
: SunspecStorageMode.CHARGE;
|
|
1501
|
+
}
|
|
1428
1502
|
export class SunspecBattery extends BaseSunspecDevice {
|
|
1429
1503
|
featureMode;
|
|
1430
1504
|
capabilities;
|
|
@@ -1455,10 +1529,59 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1455
1529
|
EnyoBatteryFeature.ChargeLimitation,
|
|
1456
1530
|
EnyoBatteryFeature.DischargeLimitation,
|
|
1457
1531
|
];
|
|
1458
|
-
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, featureMode, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls
|
|
1532
|
+
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, featureMode, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls,
|
|
1533
|
+
// Battery facts no register carries (currently the measured round-trip efficiency).
|
|
1534
|
+
// Forwarded onto `appliance.battery` on connect; see SunspecBatteryMetadataConfig.
|
|
1535
|
+
metadataConfig = {}) {
|
|
1459
1536
|
super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
|
|
1460
1537
|
this.featureMode = featureMode;
|
|
1461
1538
|
this.capabilities = capabilities;
|
|
1539
|
+
this.roundTripEfficiencyPercent = metadataConfig.roundTripEfficiencyPercent;
|
|
1540
|
+
}
|
|
1541
|
+
/**
|
|
1542
|
+
* Last known round-trip efficiency, seeded from the constructor config and replaceable at
|
|
1543
|
+
* runtime via {@link setRoundTripEfficiencyPercent}. Undefined = not yet known; the SDK then
|
|
1544
|
+
* writes nothing, leaving whatever the appliance store already holds.
|
|
1545
|
+
*/
|
|
1546
|
+
roundTripEfficiencyPercent;
|
|
1547
|
+
/**
|
|
1548
|
+
* Update the battery's measured round-trip efficiency (percent, 0-100) and push it to the
|
|
1549
|
+
* appliance immediately. Meant to be called whenever the host recomputes the figure from
|
|
1550
|
+
* completed cycles - it drifts with cell age and temperature, so a value fixed at construction
|
|
1551
|
+
* goes stale. Pass `undefined` to stop asserting a value (the last published one stays in the
|
|
1552
|
+
* appliance store; the SDK does not erase it).
|
|
1553
|
+
*
|
|
1554
|
+
* Safe to call before {@link connect}: the value is remembered and published with the rest of
|
|
1555
|
+
* the metadata once the appliance exists.
|
|
1556
|
+
*/
|
|
1557
|
+
async setRoundTripEfficiencyPercent(percent) {
|
|
1558
|
+
if (percent !== undefined && (!Number.isFinite(percent) || percent < 0 || percent > 100)) {
|
|
1559
|
+
throw new Error(`setRoundTripEfficiencyPercent: ${percent} is not a percentage between 0 and 100`);
|
|
1560
|
+
}
|
|
1561
|
+
this.roundTripEfficiencyPercent = percent;
|
|
1562
|
+
if (percent === undefined || !this.applianceId)
|
|
1563
|
+
return;
|
|
1564
|
+
try {
|
|
1565
|
+
const existingAppliance = await this.applianceManager.findApplianceById(this.applianceId);
|
|
1566
|
+
await this.applianceManager.updateAppliance(this.applianceId, {
|
|
1567
|
+
battery: {
|
|
1568
|
+
...existingAppliance?.battery,
|
|
1569
|
+
roundTripEfficiencyPercent: percent
|
|
1570
|
+
}
|
|
1571
|
+
});
|
|
1572
|
+
}
|
|
1573
|
+
catch (error) {
|
|
1574
|
+
console.error(`Failed to publish round-trip efficiency for battery ${this.applianceId}: ${error}`);
|
|
1575
|
+
}
|
|
1576
|
+
}
|
|
1577
|
+
/**
|
|
1578
|
+
* The configured battery facts as a spreadable object holding only the keys actually known.
|
|
1579
|
+
* Spreading an explicit `undefined` would erase a value the host set elsewhere.
|
|
1580
|
+
*/
|
|
1581
|
+
configuredBatteryMetadata() {
|
|
1582
|
+
return this.roundTripEfficiencyPercent === undefined
|
|
1583
|
+
? {}
|
|
1584
|
+
: { roundTripEfficiencyPercent: this.roundTripEfficiencyPercent };
|
|
1462
1585
|
}
|
|
1463
1586
|
/**
|
|
1464
1587
|
* Wire the battery into `@enyo-energy/appliance-calibration`'s
|
|
@@ -1579,12 +1702,13 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1579
1702
|
battery: {
|
|
1580
1703
|
connectedToApplianceId: inverterApplianceId,
|
|
1581
1704
|
storageMode: this.mapToEnyoStorageMode(storageMode),
|
|
1582
|
-
maxChargingPowerW: batteryData
|
|
1705
|
+
maxChargingPowerW: batteryData?.wChaMax,
|
|
1583
1706
|
maxDischargePowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.outWRte !== undefined ? batteryData.wChaMax * batteryData.outWRte : undefined,
|
|
1584
1707
|
activeChargeLimitW: activeChargeLimitW,
|
|
1585
1708
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
1586
1709
|
features,
|
|
1587
|
-
gridChargingEnabled: batteryData?.chaGriSet === 1
|
|
1710
|
+
gridChargingEnabled: batteryData?.chaGriSet === 1,
|
|
1711
|
+
...this.configuredBatteryMetadata()
|
|
1588
1712
|
}
|
|
1589
1713
|
});
|
|
1590
1714
|
console.log(`Sunspec Battery connected: ${this.networkDevice.hostname} (${this.applianceId})`);
|
|
@@ -1607,12 +1731,13 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1607
1731
|
...existingAppliance?.battery,
|
|
1608
1732
|
connectedToApplianceId: inverterApplianceId,
|
|
1609
1733
|
storageMode: this.mapToEnyoStorageMode(storageMode),
|
|
1610
|
-
maxChargingPowerW: batteryData
|
|
1734
|
+
maxChargingPowerW: batteryData?.wChaMax,
|
|
1611
1735
|
maxDischargePowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.outWRte !== undefined ? batteryData.wChaMax * batteryData.outWRte : undefined,
|
|
1612
1736
|
activeChargeLimitW: activeChargeLimitW,
|
|
1613
1737
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
1614
1738
|
features,
|
|
1615
|
-
gridChargingEnabled: batteryData?.chaGriSet === 1
|
|
1739
|
+
gridChargingEnabled: batteryData?.chaGriSet === 1,
|
|
1740
|
+
...this.configuredBatteryMetadata()
|
|
1616
1741
|
}
|
|
1617
1742
|
});
|
|
1618
1743
|
console.log(`Sunspec Battery connected: ${this.networkDevice.hostname} (${this.applianceId})`);
|
|
@@ -1766,12 +1891,13 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1766
1891
|
battery: {
|
|
1767
1892
|
...appliance?.battery,
|
|
1768
1893
|
storageMode: this.mapToEnyoStorageMode(storageMode),
|
|
1769
|
-
maxChargingPowerW: batteryData
|
|
1894
|
+
maxChargingPowerW: batteryData?.wChaMax,
|
|
1770
1895
|
maxDischargePowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.outWRte !== undefined ? batteryData.wChaMax * batteryData.outWRte : undefined,
|
|
1771
1896
|
activeChargeLimitW: this.computeActiveChargeLimitW(batteryData),
|
|
1772
1897
|
activeDischargeLimitW: this.computeActiveDischargeLimitW(batteryData),
|
|
1773
1898
|
features,
|
|
1774
|
-
gridChargingEnabled: batteryData?.chaGriSet === 1
|
|
1899
|
+
gridChargingEnabled: batteryData?.chaGriSet === 1,
|
|
1900
|
+
...this.configuredBatteryMetadata()
|
|
1775
1901
|
}
|
|
1776
1902
|
});
|
|
1777
1903
|
}
|
|
@@ -1970,23 +2096,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1970
2096
|
return (batteryData.wChaMax * batteryData.outWRte) / 100;
|
|
1971
2097
|
}
|
|
1972
2098
|
determineStorageMode(controls) {
|
|
1973
|
-
|
|
1974
|
-
return null;
|
|
1975
|
-
}
|
|
1976
|
-
const chargeEnabled = (controls.storCtlMod & 0x0001) !== 0;
|
|
1977
|
-
const dischargeEnabled = (controls.storCtlMod & 0x0002) !== 0;
|
|
1978
|
-
if (chargeEnabled && dischargeEnabled) {
|
|
1979
|
-
return SunspecStorageMode.AUTO;
|
|
1980
|
-
}
|
|
1981
|
-
else if (chargeEnabled && !dischargeEnabled) {
|
|
1982
|
-
return SunspecStorageMode.CHARGE;
|
|
1983
|
-
}
|
|
1984
|
-
else if (!chargeEnabled && dischargeEnabled) {
|
|
1985
|
-
return SunspecStorageMode.DISCHARGE;
|
|
1986
|
-
}
|
|
1987
|
-
else {
|
|
1988
|
-
return SunspecStorageMode.HOLDING;
|
|
1989
|
-
}
|
|
2099
|
+
return deriveStorageMode(controls);
|
|
1990
2100
|
}
|
|
1991
2101
|
/**
|
|
1992
2102
|
* Check if grid charging is enabled
|
|
@@ -46,6 +46,26 @@ export interface IModbusPacingConfig {
|
|
|
46
46
|
*/
|
|
47
47
|
waitBetweenMessagesMs?: number;
|
|
48
48
|
}
|
|
49
|
+
/**
|
|
50
|
+
* Everything the client forwards verbatim to `useModbus().connect()`: the pacing options above plus
|
|
51
|
+
* the transport options added in energy-app-sdk 1.6.0. Kept as a superset of
|
|
52
|
+
* {@link IModbusPacingConfig} so callers that already pass a pacing object keep working unchanged.
|
|
53
|
+
*/
|
|
54
|
+
export interface IModbusTransportConfig extends IModbusPacingConfig {
|
|
55
|
+
/**
|
|
56
|
+
* Take the connection from the host's shared pool of sockets — keyed by host, port, unit ID and
|
|
57
|
+
* transport settings — instead of opening one that belongs exclusively to this client (SDK
|
|
58
|
+
* `ModbusOptions.pooledConnection`, available from energy-app-sdk 1.6.0). Pooling lets several
|
|
59
|
+
* consumers of the same physical device share one TCP connection, which matters for devices that
|
|
60
|
+
* accept only a handful of simultaneous Modbus clients. A pooled `disconnect()` releases the
|
|
61
|
+
* connection back to the pool rather than necessarily closing the socket.
|
|
62
|
+
*
|
|
63
|
+
* Note that this SDK already refcounts one client per `host:port`
|
|
64
|
+
* ({@link getOrCreateSunspecClient}), so pooling only adds anything when something *outside* this
|
|
65
|
+
* client also talks to the same device. Leave it unset to keep the SDK's own default.
|
|
66
|
+
*/
|
|
67
|
+
pooledConnection?: boolean;
|
|
68
|
+
}
|
|
49
69
|
/**
|
|
50
70
|
* Resilience configuration for the Modbus client: per-operation timeouts and half-open socket
|
|
51
71
|
* detection. All fields are optional and default to sensible values, so existing consumers are
|
|
@@ -503,7 +523,14 @@ export declare enum SunspecBatteryEvent1 {
|
|
|
503
523
|
* - To ensure external control works properly, the appropriate bits must be set
|
|
504
524
|
*/
|
|
505
525
|
export declare enum SunspecStorageControlMode {
|
|
506
|
-
|
|
526
|
+
/**
|
|
527
|
+
* No bit set — no external setpoint is active and the battery runs its own
|
|
528
|
+
* autonomous logic. This, not `CHARGE | DISCHARGE`, is what "auto" means on
|
|
529
|
+
* Model 124: the bits say *which rate setpoint is being enforced*, so
|
|
530
|
+
* clearing them is what hands control back to the device.
|
|
531
|
+
*/
|
|
532
|
+
NONE = 0,
|
|
533
|
+
CHARGE = 1,// Bit 0 - the InWRte charge-rate setpoint is active
|
|
507
534
|
DISCHARGE = 2
|
|
508
535
|
}
|
|
509
536
|
/**
|
|
@@ -778,9 +805,9 @@ export declare enum SunspecChargeSource {
|
|
|
778
805
|
* Storage modes for simplified battery control
|
|
779
806
|
*/
|
|
780
807
|
export declare enum SunspecStorageMode {
|
|
781
|
-
CHARGE = "charge",//
|
|
782
|
-
DISCHARGE = "discharge",//
|
|
783
|
-
HOLDING = "holding",//
|
|
808
|
+
CHARGE = "charge",// Charging is externally rate-limited via InWRte
|
|
809
|
+
DISCHARGE = "discharge",// Discharging is externally rate-limited via OutWRte
|
|
810
|
+
HOLDING = "holding",// Both directions clamped to 0 % — battery is parked
|
|
784
811
|
AUTO = "auto"
|
|
785
812
|
}
|
|
786
813
|
/**
|
|
@@ -795,6 +822,29 @@ export declare enum SunspecStorageMode {
|
|
|
795
822
|
export declare enum SunspecInverterCapability {
|
|
796
823
|
FeedInLimit = "feed-in-limit"
|
|
797
824
|
}
|
|
825
|
+
/**
|
|
826
|
+
* Nameplate/policy facts about an inverter that live outside the SunSpec register map, published
|
|
827
|
+
* onto `appliance.inverter` when the device connects. Nothing here is readable from Modbus — the
|
|
828
|
+
* installation record (Anlagenpass) or the host's own configuration is the source of truth — so the
|
|
829
|
+
* SDK only forwards what the consumer supplies. Fields left `undefined` are not written, so an
|
|
830
|
+
* existing value in the appliance store survives a reconnect.
|
|
831
|
+
*
|
|
832
|
+
* Both fields were added to the appliance model in energy-app-sdk 1.6.0.
|
|
833
|
+
*/
|
|
834
|
+
export interface SunspecInverterMetadataConfig {
|
|
835
|
+
/**
|
|
836
|
+
* Whether the energy manager may actively steer this inverter (e.g. curtail production). Omit
|
|
837
|
+
* to leave the decision to the consumer's configured default — `undefined` is "not configured",
|
|
838
|
+
* which is not the same as `false`.
|
|
839
|
+
*/
|
|
840
|
+
controlAllowed?: boolean;
|
|
841
|
+
/**
|
|
842
|
+
* Peak power of the PV modules attached to this inverter, in Watt-peak. Distinct from
|
|
843
|
+
* `maxPvProductionW`, which the SDK reads from the inverter's own AC nameplate (Model 121
|
|
844
|
+
* `WMax`): the module side of the installation is not in any register.
|
|
845
|
+
*/
|
|
846
|
+
installedPeakPowerWp?: number;
|
|
847
|
+
}
|
|
798
848
|
/**
|
|
799
849
|
* Where an inverter's reported PV production (pvPowerW) is sourced from.
|
|
800
850
|
* - Auto: summed MPPT DC strings (Model 160) when present, else the inverter's
|
|
@@ -905,6 +955,25 @@ export declare enum SunspecBatteryCapability {
|
|
|
905
955
|
DischargeLimit = "discharge-limit",
|
|
906
956
|
ChargeLimit = "charge-limit"
|
|
907
957
|
}
|
|
958
|
+
/**
|
|
959
|
+
* Battery facts that live outside the SunSpec register map, published onto `appliance.battery` when
|
|
960
|
+
* the device connects. Fields left `undefined` are not written, so an existing value in the
|
|
961
|
+
* appliance store survives a reconnect.
|
|
962
|
+
*/
|
|
963
|
+
export interface SunspecBatteryMetadataConfig {
|
|
964
|
+
/**
|
|
965
|
+
* Observed AC-to-AC round-trip efficiency in percent (0–100): of the energy put into the
|
|
966
|
+
* battery, how much comes back out. Added to the appliance model in energy-app-sdk 1.6.0.
|
|
967
|
+
*
|
|
968
|
+
* A *measured* figure, not a datasheet one — it drifts with cell age, temperature and depth of
|
|
969
|
+
* discharge, and no SunSpec model reports it, so the SDK cannot derive it. Supply it from
|
|
970
|
+
* whatever the host computes over completed cycles, either here at construction or later via
|
|
971
|
+
* {@link SunspecBattery.setRoundTripEfficiencyPercent}. Leave it unset until enough cycles have
|
|
972
|
+
* been observed: a missing value means "not yet known", and is more useful to an optimizer than
|
|
973
|
+
* a nameplate number that overstates what the pack returns.
|
|
974
|
+
*/
|
|
975
|
+
roundTripEfficiencyPercent?: number;
|
|
976
|
+
}
|
|
908
977
|
/**
|
|
909
978
|
* Selects how `SunspecBattery` populates `appliance.battery.features`.
|
|
910
979
|
*
|
|
@@ -213,8 +213,15 @@ export var SunspecBatteryEvent1;
|
|
|
213
213
|
*/
|
|
214
214
|
export var SunspecStorageControlMode;
|
|
215
215
|
(function (SunspecStorageControlMode) {
|
|
216
|
+
/**
|
|
217
|
+
* No bit set — no external setpoint is active and the battery runs its own
|
|
218
|
+
* autonomous logic. This, not `CHARGE | DISCHARGE`, is what "auto" means on
|
|
219
|
+
* Model 124: the bits say *which rate setpoint is being enforced*, so
|
|
220
|
+
* clearing them is what hands control back to the device.
|
|
221
|
+
*/
|
|
222
|
+
SunspecStorageControlMode[SunspecStorageControlMode["NONE"] = 0] = "NONE";
|
|
216
223
|
SunspecStorageControlMode[SunspecStorageControlMode["CHARGE"] = 1] = "CHARGE";
|
|
217
|
-
SunspecStorageControlMode[SunspecStorageControlMode["DISCHARGE"] = 2] = "DISCHARGE"; // Bit 1 -
|
|
224
|
+
SunspecStorageControlMode[SunspecStorageControlMode["DISCHARGE"] = 2] = "DISCHARGE"; // Bit 1 - the OutWRte discharge-rate setpoint is active
|
|
218
225
|
// Note: Higher bits may control other modes like autonomous/self-consumption
|
|
219
226
|
// but these are device-specific and not standardized in SunSpec
|
|
220
227
|
})(SunspecStorageControlMode || (SunspecStorageControlMode = {}));
|
|
@@ -259,7 +266,7 @@ export var SunspecStorageMode;
|
|
|
259
266
|
SunspecStorageMode["CHARGE"] = "charge";
|
|
260
267
|
SunspecStorageMode["DISCHARGE"] = "discharge";
|
|
261
268
|
SunspecStorageMode["HOLDING"] = "holding";
|
|
262
|
-
SunspecStorageMode["AUTO"] = "auto"; //
|
|
269
|
+
SunspecStorageMode["AUTO"] = "auto"; // No external setpoint active (StorCtl_Mod = 0)
|
|
263
270
|
})(SunspecStorageMode || (SunspecStorageMode = {}));
|
|
264
271
|
/**
|
|
265
272
|
* Battery control structure for writing to Model 124
|
|
@@ -16,7 +16,7 @@
|
|
|
16
16
|
* - pad: 0x8000 (always returns this value)
|
|
17
17
|
* - string: all registers 0x0000 (NULL)
|
|
18
18
|
*/
|
|
19
|
-
import { type SunspecInverterControls, type SunspecInverterData, type SunspecInverterSettings, type SunspecMeterData, type SunspecModel, type SunspecMPPTData, type SunspecBatteryData, type SunspecBatteryBaseData, type SunspecBatteryControls, SunspecStorageMode, type
|
|
19
|
+
import { type SunspecInverterControls, type SunspecInverterData, type SunspecInverterSettings, type SunspecMeterData, type SunspecModel, type SunspecMPPTData, type SunspecBatteryData, type SunspecBatteryBaseData, type SunspecBatteryControls, SunspecStorageMode, type IModbusTransportConfig, type IModbusResilienceConfig } from "./sunspec-interfaces.js";
|
|
20
20
|
import { EnergyAppModbusDataType, IConnectionHealth } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/interfaces.js";
|
|
21
21
|
import { EnergyAppModbus, EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
|
|
22
22
|
import { EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
@@ -29,12 +29,61 @@ export declare class ModbusOperationTimeoutError extends Error {
|
|
|
29
29
|
readonly unitId: number;
|
|
30
30
|
readonly timeoutMs: number;
|
|
31
31
|
constructor(operation: string, unitId: number, timeoutMs: number);
|
|
32
|
+
/**
|
|
33
|
+
* `Error` has no enumerable own properties, so a consumer that logs `{ err }` through a
|
|
34
|
+
* JSON serializer emits `{}` and loses the message entirely. Give every error this client
|
|
35
|
+
* rejects with an explicit JSON shape so it survives `JSON.stringify` with a usable message.
|
|
36
|
+
*/
|
|
37
|
+
toJSON(): {
|
|
38
|
+
name: string;
|
|
39
|
+
message: string;
|
|
40
|
+
operation: string;
|
|
41
|
+
unitId: number;
|
|
42
|
+
timeoutMs: number;
|
|
43
|
+
};
|
|
44
|
+
}
|
|
45
|
+
/**
|
|
46
|
+
* Why a unit is refusing I/O without having attempted it. A discriminant field rather than a
|
|
47
|
+
* class hierarchy, so consumers can branch on the cause with a plain `===`.
|
|
48
|
+
*/
|
|
49
|
+
export type SunspecUnavailableReason = 'socket-poisoned';
|
|
50
|
+
/**
|
|
51
|
+
* Thrown when the client refuses a transaction because the unit is **already known to be down**,
|
|
52
|
+
* as opposed to a transaction that was actually attempted and failed.
|
|
53
|
+
*
|
|
54
|
+
* The distinction matters for logging. A poisoned socket produces exactly one genuine event (the
|
|
55
|
+
* timeout that poisoned it), but every read that lands during the outage would otherwise throw an
|
|
56
|
+
* error indistinguishable from real I/O failure — so a consumer catching per read has no choice but
|
|
57
|
+
* to log each one at ERROR. Callers should log the first {@link SunspecUnavailableError} of an
|
|
58
|
+
* outage (or nothing at all: the SDK already logs the transition) and stay quiet on the rest.
|
|
59
|
+
*
|
|
60
|
+
* {@link sinceMs} is how long the unit has been in this state, so a consumer that does want one
|
|
61
|
+
* line can say how stale the link is without tracking the outage itself.
|
|
62
|
+
*/
|
|
63
|
+
export declare class SunspecUnavailableError extends Error {
|
|
64
|
+
readonly reason: SunspecUnavailableReason;
|
|
65
|
+
readonly unitId: number;
|
|
66
|
+
readonly sinceMs: number;
|
|
67
|
+
constructor(reason: SunspecUnavailableReason, unitId: number, sinceMs: number);
|
|
68
|
+
/** See {@link ModbusOperationTimeoutError.toJSON}. */
|
|
69
|
+
toJSON(): {
|
|
70
|
+
name: string;
|
|
71
|
+
message: string;
|
|
72
|
+
reason: SunspecUnavailableReason;
|
|
73
|
+
unitId: number;
|
|
74
|
+
sinceMs: number;
|
|
75
|
+
};
|
|
32
76
|
}
|
|
77
|
+
/**
|
|
78
|
+
* Type guard for {@link SunspecUnavailableError}. Prefer this over `instanceof` at package
|
|
79
|
+
* boundaries, where a duplicated copy of the SDK in the module graph would break identity.
|
|
80
|
+
*/
|
|
81
|
+
export declare function isSunspecUnavailableError(error: unknown): error is SunspecUnavailableError;
|
|
33
82
|
/**
|
|
34
83
|
* Get (or create) the singleton SunspecModbusClient for this network device.
|
|
35
84
|
* Increments the refcount; pair with `releaseSunspecClient` on teardown.
|
|
36
85
|
*
|
|
37
|
-
* NOTE: `
|
|
86
|
+
* NOTE: `transport`, `resilience` and `modbusFactory` are only applied when the client is FIRST
|
|
38
87
|
* created for a given host:port. Because the client is cached and refcounted, a later caller
|
|
39
88
|
* passing different config receives the already-created instance and its config is ignored.
|
|
40
89
|
*
|
|
@@ -42,7 +91,7 @@ export declare class ModbusOperationTimeoutError extends Error {
|
|
|
42
91
|
* opens a per-unit connection) instead of the one from `energyApp.useModbus()` — e.g. a mock for
|
|
43
92
|
* tests, or an alternative transport. When provided, `energyApp` may be passed as `undefined`.
|
|
44
93
|
*/
|
|
45
|
-
export declare function getOrCreateSunspecClient(energyApp: EnergyApp | undefined, host: string, port?: number,
|
|
94
|
+
export declare function getOrCreateSunspecClient(energyApp: EnergyApp | undefined, host: string, port?: number, transport?: IModbusTransportConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus): SunspecModbusClient;
|
|
46
95
|
/**
|
|
47
96
|
* Release a refcount on the network-device client. When the last consumer releases,
|
|
48
97
|
* the client is fully disconnected (all units closed) and removed from the registry.
|
|
@@ -66,7 +115,7 @@ export declare function retryAsync<T>(fn: (attempt: number) => Promise<T>, opts:
|
|
|
66
115
|
}): Promise<T>;
|
|
67
116
|
export declare class SunspecModbusClient {
|
|
68
117
|
private energyApp;
|
|
69
|
-
private
|
|
118
|
+
private transport;
|
|
70
119
|
private modbusFactory?;
|
|
71
120
|
private modbusInstances;
|
|
72
121
|
private faultTolerantReaders;
|
|
@@ -83,8 +132,10 @@ export declare class SunspecModbusClient {
|
|
|
83
132
|
private txChains;
|
|
84
133
|
private resilience;
|
|
85
134
|
private poisonedUnits;
|
|
135
|
+
private poisonedAtByUnit;
|
|
86
136
|
private lastOkAtByUnit;
|
|
87
|
-
|
|
137
|
+
private consecutiveConnectFailures;
|
|
138
|
+
constructor(energyApp: EnergyApp | undefined, transport?: IModbusTransportConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
|
|
88
139
|
/**
|
|
89
140
|
* The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
|
|
90
141
|
* if one was given, otherwise the host application's default (`energyApp.useModbus()`). The
|
|
@@ -238,12 +289,38 @@ export declare class SunspecModbusClient {
|
|
|
238
289
|
* timer is always cleared so a fast `fn` doesn't keep the event loop alive.
|
|
239
290
|
*/
|
|
240
291
|
private withTimeout;
|
|
292
|
+
/**
|
|
293
|
+
* Log a failed Modbus transaction from a reader/writer catch block.
|
|
294
|
+
*
|
|
295
|
+
* A {@link SunspecUnavailableError} is not a failure — it is this client refusing I/O on a link
|
|
296
|
+
* it has already reported dead once (one WARN on the transition, one INFO on recovery). Logging
|
|
297
|
+
* it at ERROR once per read, per read path, per poll cycle, for the whole outage, is what buries
|
|
298
|
+
* the errors that are actually actionable. So it drops to debug; everything else stays ERROR.
|
|
299
|
+
*/
|
|
300
|
+
private logConnectFailure;
|
|
301
|
+
/** True while `key`'s last attempt failed — used to keep repeat attempt chatter at debug. */
|
|
302
|
+
private isRetryingAfterFailure;
|
|
303
|
+
/** Forget `key`'s failure run on a success, so the next outage logs its first failure again. */
|
|
304
|
+
private clearConnectFailures;
|
|
305
|
+
private logTransactionError;
|
|
241
306
|
/**
|
|
242
307
|
* Mark a unit's socket as poisoned after a timeout and reflect the hang in the shared health
|
|
243
308
|
* gate immediately, so isHealthy() flips false this cycle instead of after the coarse
|
|
244
309
|
* 5-failure / 5-minute-staleness thresholds. Idempotent; only logs on the first poison.
|
|
245
310
|
*/
|
|
246
311
|
private poisonUnit;
|
|
312
|
+
/**
|
|
313
|
+
* Enter the poisoned state for a unit, logging the TRANSITION only. Everything downstream of
|
|
314
|
+
* this (every refused read, every poll cycle) is the same known state and must stay silent —
|
|
315
|
+
* one WARN in, one INFO out (see {@link logPoisonRecovery}), nothing in between.
|
|
316
|
+
*/
|
|
317
|
+
private enterPoisoned;
|
|
318
|
+
/**
|
|
319
|
+
* Close out a poisoned episode on a successful (re)open: one INFO carrying how long the unit
|
|
320
|
+
* was refusing I/O. No-op for a unit that was never poisoned, so a normal first connect stays
|
|
321
|
+
* quiet.
|
|
322
|
+
*/
|
|
323
|
+
private logPoisonRecovery;
|
|
247
324
|
/**
|
|
248
325
|
* Publicly invalidate a unit's socket so {@link isHealthy} returns false and the next
|
|
249
326
|
* readData()/tryReconnect() cycle recycles it — the same effect as a timeout poison but
|