@enyo-energy/sunspec-sdk 0.0.104 → 1.0.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +90 -0
- package/dist/cjs/sunspec-battery-schedule-handler.cjs +76 -28
- package/dist/cjs/sunspec-battery-schedule-handler.d.cts +33 -6
- package/dist/cjs/sunspec-devices.cjs +140 -29
- package/dist/cjs/sunspec-devices.d.cts +47 -3
- package/dist/cjs/sunspec-interfaces.cjs +9 -2
- package/dist/cjs/sunspec-interfaces.d.cts +73 -4
- package/dist/cjs/sunspec-modbus-client.cjs +280 -116
- package/dist/cjs/sunspec-modbus-client.d.cts +82 -5
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-battery-schedule-handler.d.ts +33 -6
- package/dist/sunspec-battery-schedule-handler.js +76 -28
- package/dist/sunspec-devices.d.ts +47 -3
- package/dist/sunspec-devices.js +139 -29
- package/dist/sunspec-interfaces.d.ts +73 -4
- package/dist/sunspec-interfaces.js +9 -2
- package/dist/sunspec-modbus-client.d.ts +82 -5
- package/dist/sunspec-modbus-client.js +277 -115
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.cjs";
|
|
1
|
+
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, type SunspecInverterMetadataConfig, type SunspecBatteryMetadataConfig, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.cjs";
|
|
2
2
|
import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
3
3
|
import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
|
|
@@ -208,6 +208,7 @@ type SunspecPvPower = {
|
|
|
208
208
|
export declare class SunspecInverter extends BaseSunspecDevice {
|
|
209
209
|
private readonly capabilities;
|
|
210
210
|
private readonly pvPowerSource;
|
|
211
|
+
private readonly metadataConfig;
|
|
211
212
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
212
213
|
private static readonly CONNECTION_FAULT_THRESHOLD;
|
|
213
214
|
/**
|
|
@@ -233,7 +234,13 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
233
234
|
private acEnergyDropStreak;
|
|
234
235
|
/** Consecutive corrupt reads that confirm a genuine reset/resync (vs a transient glitch). */
|
|
235
236
|
private static readonly AC_ENERGY_RESET_CONFIRM;
|
|
236
|
-
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource);
|
|
237
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource, metadataConfig?: SunspecInverterMetadataConfig);
|
|
238
|
+
/**
|
|
239
|
+
* The consumer-supplied inverter facts, as a spreadable object that only contains the keys that
|
|
240
|
+
* were actually configured. Spreading `{ controlAllowed: undefined }` over an existing appliance
|
|
241
|
+
* would erase a value the host set elsewhere; omitting the key leaves it alone.
|
|
242
|
+
*/
|
|
243
|
+
private configuredInverterMetadata;
|
|
237
244
|
connect(): Promise<void>;
|
|
238
245
|
disconnect(): Promise<void>;
|
|
239
246
|
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
@@ -510,6 +517,21 @@ export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryF
|
|
|
510
517
|
/**
|
|
511
518
|
* Sunspec Battery implementation
|
|
512
519
|
*/
|
|
520
|
+
/**
|
|
521
|
+
* Derive the storage mode from Model 124's StorCtl_Mod bitfield.
|
|
522
|
+
*
|
|
523
|
+
* The bits mark *which rate setpoint the device is enforcing* — bit 0 for
|
|
524
|
+
* InWRte, bit 1 for OutWRte — not which direction is permitted. So no bit set
|
|
525
|
+
* is the autonomous mode, and both bits set is the most externally controlled
|
|
526
|
+
* state there is, which is the opposite of what the naming suggests. Reading
|
|
527
|
+
* them the other way round meant a battery running its own logic reported
|
|
528
|
+
* `holding`, a fully clamped one reported `auto`, and no appliance could ever
|
|
529
|
+
* report that it had been handed back to itself.
|
|
530
|
+
*
|
|
531
|
+
* @param controls - Model 124 control registers, or null when unreadable.
|
|
532
|
+
* @returns The mode, or null when StorCtl_Mod could not be read.
|
|
533
|
+
*/
|
|
534
|
+
export declare function deriveStorageMode(controls: SunspecBatteryControls | null): SunspecStorageMode | null;
|
|
513
535
|
export declare class SunspecBattery extends BaseSunspecDevice {
|
|
514
536
|
private readonly featureMode;
|
|
515
537
|
private readonly capabilities;
|
|
@@ -532,7 +554,29 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
532
554
|
* {@link computeAdvertisedFeatures}.
|
|
533
555
|
*/
|
|
534
556
|
private static readonly CONTROLLABLE_FEATURES;
|
|
535
|
-
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
|
|
557
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, metadataConfig?: SunspecBatteryMetadataConfig);
|
|
558
|
+
/**
|
|
559
|
+
* Last known round-trip efficiency, seeded from the constructor config and replaceable at
|
|
560
|
+
* runtime via {@link setRoundTripEfficiencyPercent}. Undefined = not yet known; the SDK then
|
|
561
|
+
* writes nothing, leaving whatever the appliance store already holds.
|
|
562
|
+
*/
|
|
563
|
+
private roundTripEfficiencyPercent?;
|
|
564
|
+
/**
|
|
565
|
+
* Update the battery's measured round-trip efficiency (percent, 0-100) and push it to the
|
|
566
|
+
* appliance immediately. Meant to be called whenever the host recomputes the figure from
|
|
567
|
+
* completed cycles - it drifts with cell age and temperature, so a value fixed at construction
|
|
568
|
+
* goes stale. Pass `undefined` to stop asserting a value (the last published one stays in the
|
|
569
|
+
* appliance store; the SDK does not erase it).
|
|
570
|
+
*
|
|
571
|
+
* Safe to call before {@link connect}: the value is remembered and published with the rest of
|
|
572
|
+
* the metadata once the appliance exists.
|
|
573
|
+
*/
|
|
574
|
+
setRoundTripEfficiencyPercent(percent: number | undefined): Promise<void>;
|
|
575
|
+
/**
|
|
576
|
+
* The configured battery facts as a spreadable object holding only the keys actually known.
|
|
577
|
+
* Spreading an explicit `undefined` would erase a value the host set elsewhere.
|
|
578
|
+
*/
|
|
579
|
+
private configuredBatteryMetadata;
|
|
536
580
|
/**
|
|
537
581
|
* Wire the battery into `@enyo-energy/appliance-calibration`'s
|
|
538
582
|
* `BatteryCalibrator` test-charge flow. Call once after {@link connect}.
|
|
@@ -216,8 +216,15 @@ var SunspecBatteryEvent1;
|
|
|
216
216
|
*/
|
|
217
217
|
var SunspecStorageControlMode;
|
|
218
218
|
(function (SunspecStorageControlMode) {
|
|
219
|
+
/**
|
|
220
|
+
* No bit set — no external setpoint is active and the battery runs its own
|
|
221
|
+
* autonomous logic. This, not `CHARGE | DISCHARGE`, is what "auto" means on
|
|
222
|
+
* Model 124: the bits say *which rate setpoint is being enforced*, so
|
|
223
|
+
* clearing them is what hands control back to the device.
|
|
224
|
+
*/
|
|
225
|
+
SunspecStorageControlMode[SunspecStorageControlMode["NONE"] = 0] = "NONE";
|
|
219
226
|
SunspecStorageControlMode[SunspecStorageControlMode["CHARGE"] = 1] = "CHARGE";
|
|
220
|
-
SunspecStorageControlMode[SunspecStorageControlMode["DISCHARGE"] = 2] = "DISCHARGE"; // Bit 1 -
|
|
227
|
+
SunspecStorageControlMode[SunspecStorageControlMode["DISCHARGE"] = 2] = "DISCHARGE"; // Bit 1 - the OutWRte discharge-rate setpoint is active
|
|
221
228
|
// Note: Higher bits may control other modes like autonomous/self-consumption
|
|
222
229
|
// but these are device-specific and not standardized in SunSpec
|
|
223
230
|
})(SunspecStorageControlMode || (exports.SunspecStorageControlMode = SunspecStorageControlMode = {}));
|
|
@@ -262,7 +269,7 @@ var SunspecStorageMode;
|
|
|
262
269
|
SunspecStorageMode["CHARGE"] = "charge";
|
|
263
270
|
SunspecStorageMode["DISCHARGE"] = "discharge";
|
|
264
271
|
SunspecStorageMode["HOLDING"] = "holding";
|
|
265
|
-
SunspecStorageMode["AUTO"] = "auto"; //
|
|
272
|
+
SunspecStorageMode["AUTO"] = "auto"; // No external setpoint active (StorCtl_Mod = 0)
|
|
266
273
|
})(SunspecStorageMode || (exports.SunspecStorageMode = SunspecStorageMode = {}));
|
|
267
274
|
/**
|
|
268
275
|
* Battery control structure for writing to Model 124
|
|
@@ -46,6 +46,26 @@ export interface IModbusPacingConfig {
|
|
|
46
46
|
*/
|
|
47
47
|
waitBetweenMessagesMs?: number;
|
|
48
48
|
}
|
|
49
|
+
/**
|
|
50
|
+
* Everything the client forwards verbatim to `useModbus().connect()`: the pacing options above plus
|
|
51
|
+
* the transport options added in energy-app-sdk 1.6.0. Kept as a superset of
|
|
52
|
+
* {@link IModbusPacingConfig} so callers that already pass a pacing object keep working unchanged.
|
|
53
|
+
*/
|
|
54
|
+
export interface IModbusTransportConfig extends IModbusPacingConfig {
|
|
55
|
+
/**
|
|
56
|
+
* Take the connection from the host's shared pool of sockets — keyed by host, port, unit ID and
|
|
57
|
+
* transport settings — instead of opening one that belongs exclusively to this client (SDK
|
|
58
|
+
* `ModbusOptions.pooledConnection`, available from energy-app-sdk 1.6.0). Pooling lets several
|
|
59
|
+
* consumers of the same physical device share one TCP connection, which matters for devices that
|
|
60
|
+
* accept only a handful of simultaneous Modbus clients. A pooled `disconnect()` releases the
|
|
61
|
+
* connection back to the pool rather than necessarily closing the socket.
|
|
62
|
+
*
|
|
63
|
+
* Note that this SDK already refcounts one client per `host:port`
|
|
64
|
+
* ({@link getOrCreateSunspecClient}), so pooling only adds anything when something *outside* this
|
|
65
|
+
* client also talks to the same device. Leave it unset to keep the SDK's own default.
|
|
66
|
+
*/
|
|
67
|
+
pooledConnection?: boolean;
|
|
68
|
+
}
|
|
49
69
|
/**
|
|
50
70
|
* Resilience configuration for the Modbus client: per-operation timeouts and half-open socket
|
|
51
71
|
* detection. All fields are optional and default to sensible values, so existing consumers are
|
|
@@ -503,7 +523,14 @@ export declare enum SunspecBatteryEvent1 {
|
|
|
503
523
|
* - To ensure external control works properly, the appropriate bits must be set
|
|
504
524
|
*/
|
|
505
525
|
export declare enum SunspecStorageControlMode {
|
|
506
|
-
|
|
526
|
+
/**
|
|
527
|
+
* No bit set — no external setpoint is active and the battery runs its own
|
|
528
|
+
* autonomous logic. This, not `CHARGE | DISCHARGE`, is what "auto" means on
|
|
529
|
+
* Model 124: the bits say *which rate setpoint is being enforced*, so
|
|
530
|
+
* clearing them is what hands control back to the device.
|
|
531
|
+
*/
|
|
532
|
+
NONE = 0,
|
|
533
|
+
CHARGE = 1,// Bit 0 - the InWRte charge-rate setpoint is active
|
|
507
534
|
DISCHARGE = 2
|
|
508
535
|
}
|
|
509
536
|
/**
|
|
@@ -778,9 +805,9 @@ export declare enum SunspecChargeSource {
|
|
|
778
805
|
* Storage modes for simplified battery control
|
|
779
806
|
*/
|
|
780
807
|
export declare enum SunspecStorageMode {
|
|
781
|
-
CHARGE = "charge",//
|
|
782
|
-
DISCHARGE = "discharge",//
|
|
783
|
-
HOLDING = "holding",//
|
|
808
|
+
CHARGE = "charge",// Charging is externally rate-limited via InWRte
|
|
809
|
+
DISCHARGE = "discharge",// Discharging is externally rate-limited via OutWRte
|
|
810
|
+
HOLDING = "holding",// Both directions clamped to 0 % — battery is parked
|
|
784
811
|
AUTO = "auto"
|
|
785
812
|
}
|
|
786
813
|
/**
|
|
@@ -795,6 +822,29 @@ export declare enum SunspecStorageMode {
|
|
|
795
822
|
export declare enum SunspecInverterCapability {
|
|
796
823
|
FeedInLimit = "feed-in-limit"
|
|
797
824
|
}
|
|
825
|
+
/**
|
|
826
|
+
* Nameplate/policy facts about an inverter that live outside the SunSpec register map, published
|
|
827
|
+
* onto `appliance.inverter` when the device connects. Nothing here is readable from Modbus — the
|
|
828
|
+
* installation record (Anlagenpass) or the host's own configuration is the source of truth — so the
|
|
829
|
+
* SDK only forwards what the consumer supplies. Fields left `undefined` are not written, so an
|
|
830
|
+
* existing value in the appliance store survives a reconnect.
|
|
831
|
+
*
|
|
832
|
+
* Both fields were added to the appliance model in energy-app-sdk 1.6.0.
|
|
833
|
+
*/
|
|
834
|
+
export interface SunspecInverterMetadataConfig {
|
|
835
|
+
/**
|
|
836
|
+
* Whether the energy manager may actively steer this inverter (e.g. curtail production). Omit
|
|
837
|
+
* to leave the decision to the consumer's configured default — `undefined` is "not configured",
|
|
838
|
+
* which is not the same as `false`.
|
|
839
|
+
*/
|
|
840
|
+
controlAllowed?: boolean;
|
|
841
|
+
/**
|
|
842
|
+
* Peak power of the PV modules attached to this inverter, in Watt-peak. Distinct from
|
|
843
|
+
* `maxPvProductionW`, which the SDK reads from the inverter's own AC nameplate (Model 121
|
|
844
|
+
* `WMax`): the module side of the installation is not in any register.
|
|
845
|
+
*/
|
|
846
|
+
installedPeakPowerWp?: number;
|
|
847
|
+
}
|
|
798
848
|
/**
|
|
799
849
|
* Where an inverter's reported PV production (pvPowerW) is sourced from.
|
|
800
850
|
* - Auto: summed MPPT DC strings (Model 160) when present, else the inverter's
|
|
@@ -905,6 +955,25 @@ export declare enum SunspecBatteryCapability {
|
|
|
905
955
|
DischargeLimit = "discharge-limit",
|
|
906
956
|
ChargeLimit = "charge-limit"
|
|
907
957
|
}
|
|
958
|
+
/**
|
|
959
|
+
* Battery facts that live outside the SunSpec register map, published onto `appliance.battery` when
|
|
960
|
+
* the device connects. Fields left `undefined` are not written, so an existing value in the
|
|
961
|
+
* appliance store survives a reconnect.
|
|
962
|
+
*/
|
|
963
|
+
export interface SunspecBatteryMetadataConfig {
|
|
964
|
+
/**
|
|
965
|
+
* Observed AC-to-AC round-trip efficiency in percent (0–100): of the energy put into the
|
|
966
|
+
* battery, how much comes back out. Added to the appliance model in energy-app-sdk 1.6.0.
|
|
967
|
+
*
|
|
968
|
+
* A *measured* figure, not a datasheet one — it drifts with cell age, temperature and depth of
|
|
969
|
+
* discharge, and no SunSpec model reports it, so the SDK cannot derive it. Supply it from
|
|
970
|
+
* whatever the host computes over completed cycles, either here at construction or later via
|
|
971
|
+
* {@link SunspecBattery.setRoundTripEfficiencyPercent}. Leave it unset until enough cycles have
|
|
972
|
+
* been observed: a missing value means "not yet known", and is more useful to an optimizer than
|
|
973
|
+
* a nameplate number that overstates what the pack returns.
|
|
974
|
+
*/
|
|
975
|
+
roundTripEfficiencyPercent?: number;
|
|
976
|
+
}
|
|
908
977
|
/**
|
|
909
978
|
* Selects how `SunspecBattery` populates `appliance.battery.features`.
|
|
910
979
|
*
|