@enyo-energy/sunspec-sdk 0.0.104 → 1.0.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -16,7 +16,7 @@
16
16
  * - pad: 0x8000 (always returns this value)
17
17
  * - string: all registers 0x0000 (NULL)
18
18
  */
19
- import { type SunspecInverterControls, type SunspecInverterData, type SunspecInverterSettings, type SunspecMeterData, type SunspecModel, type SunspecMPPTData, type SunspecBatteryData, type SunspecBatteryBaseData, type SunspecBatteryControls, SunspecStorageMode, type IModbusPacingConfig, type IModbusResilienceConfig } from "./sunspec-interfaces.cjs";
19
+ import { type SunspecInverterControls, type SunspecInverterData, type SunspecInverterSettings, type SunspecMeterData, type SunspecModel, type SunspecMPPTData, type SunspecBatteryData, type SunspecBatteryBaseData, type SunspecBatteryControls, SunspecStorageMode, type IModbusTransportConfig, type IModbusResilienceConfig } from "./sunspec-interfaces.cjs";
20
20
  import { EnergyAppModbusDataType, IConnectionHealth } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/interfaces.js";
21
21
  import { EnergyAppModbus, EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
22
22
  import { EnergyApp } from "@enyo-energy/energy-app-sdk";
@@ -29,12 +29,61 @@ export declare class ModbusOperationTimeoutError extends Error {
29
29
  readonly unitId: number;
30
30
  readonly timeoutMs: number;
31
31
  constructor(operation: string, unitId: number, timeoutMs: number);
32
+ /**
33
+ * `Error` has no enumerable own properties, so a consumer that logs `{ err }` through a
34
+ * JSON serializer emits `{}` and loses the message entirely. Give every error this client
35
+ * rejects with an explicit JSON shape so it survives `JSON.stringify` with a usable message.
36
+ */
37
+ toJSON(): {
38
+ name: string;
39
+ message: string;
40
+ operation: string;
41
+ unitId: number;
42
+ timeoutMs: number;
43
+ };
44
+ }
45
+ /**
46
+ * Why a unit is refusing I/O without having attempted it. A discriminant field rather than a
47
+ * class hierarchy, so consumers can branch on the cause with a plain `===`.
48
+ */
49
+ export type SunspecUnavailableReason = 'socket-poisoned';
50
+ /**
51
+ * Thrown when the client refuses a transaction because the unit is **already known to be down**,
52
+ * as opposed to a transaction that was actually attempted and failed.
53
+ *
54
+ * The distinction matters for logging. A poisoned socket produces exactly one genuine event (the
55
+ * timeout that poisoned it), but every read that lands during the outage would otherwise throw an
56
+ * error indistinguishable from real I/O failure — so a consumer catching per read has no choice but
57
+ * to log each one at ERROR. Callers should log the first {@link SunspecUnavailableError} of an
58
+ * outage (or nothing at all: the SDK already logs the transition) and stay quiet on the rest.
59
+ *
60
+ * {@link sinceMs} is how long the unit has been in this state, so a consumer that does want one
61
+ * line can say how stale the link is without tracking the outage itself.
62
+ */
63
+ export declare class SunspecUnavailableError extends Error {
64
+ readonly reason: SunspecUnavailableReason;
65
+ readonly unitId: number;
66
+ readonly sinceMs: number;
67
+ constructor(reason: SunspecUnavailableReason, unitId: number, sinceMs: number);
68
+ /** See {@link ModbusOperationTimeoutError.toJSON}. */
69
+ toJSON(): {
70
+ name: string;
71
+ message: string;
72
+ reason: SunspecUnavailableReason;
73
+ unitId: number;
74
+ sinceMs: number;
75
+ };
32
76
  }
77
+ /**
78
+ * Type guard for {@link SunspecUnavailableError}. Prefer this over `instanceof` at package
79
+ * boundaries, where a duplicated copy of the SDK in the module graph would break identity.
80
+ */
81
+ export declare function isSunspecUnavailableError(error: unknown): error is SunspecUnavailableError;
33
82
  /**
34
83
  * Get (or create) the singleton SunspecModbusClient for this network device.
35
84
  * Increments the refcount; pair with `releaseSunspecClient` on teardown.
36
85
  *
37
- * NOTE: `pacing`, `resilience` and `modbusFactory` are only applied when the client is FIRST
86
+ * NOTE: `transport`, `resilience` and `modbusFactory` are only applied when the client is FIRST
38
87
  * created for a given host:port. Because the client is cached and refcounted, a later caller
39
88
  * passing different config receives the already-created instance and its config is ignored.
40
89
  *
@@ -42,7 +91,7 @@ export declare class ModbusOperationTimeoutError extends Error {
42
91
  * opens a per-unit connection) instead of the one from `energyApp.useModbus()` — e.g. a mock for
43
92
  * tests, or an alternative transport. When provided, `energyApp` may be passed as `undefined`.
44
93
  */
45
- export declare function getOrCreateSunspecClient(energyApp: EnergyApp | undefined, host: string, port?: number, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus): SunspecModbusClient;
94
+ export declare function getOrCreateSunspecClient(energyApp: EnergyApp | undefined, host: string, port?: number, transport?: IModbusTransportConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus): SunspecModbusClient;
46
95
  /**
47
96
  * Release a refcount on the network-device client. When the last consumer releases,
48
97
  * the client is fully disconnected (all units closed) and removed from the registry.
@@ -66,7 +115,7 @@ export declare function retryAsync<T>(fn: (attempt: number) => Promise<T>, opts:
66
115
  }): Promise<T>;
67
116
  export declare class SunspecModbusClient {
68
117
  private energyApp;
69
- private pacing;
118
+ private transport;
70
119
  private modbusFactory?;
71
120
  private modbusInstances;
72
121
  private faultTolerantReaders;
@@ -83,8 +132,10 @@ export declare class SunspecModbusClient {
83
132
  private txChains;
84
133
  private resilience;
85
134
  private poisonedUnits;
135
+ private poisonedAtByUnit;
86
136
  private lastOkAtByUnit;
87
- constructor(energyApp: EnergyApp | undefined, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
137
+ private consecutiveConnectFailures;
138
+ constructor(energyApp: EnergyApp | undefined, transport?: IModbusTransportConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
88
139
  /**
89
140
  * The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
90
141
  * if one was given, otherwise the host application's default (`energyApp.useModbus()`). The
@@ -238,12 +289,38 @@ export declare class SunspecModbusClient {
238
289
  * timer is always cleared so a fast `fn` doesn't keep the event loop alive.
239
290
  */
240
291
  private withTimeout;
292
+ /**
293
+ * Log a failed Modbus transaction from a reader/writer catch block.
294
+ *
295
+ * A {@link SunspecUnavailableError} is not a failure — it is this client refusing I/O on a link
296
+ * it has already reported dead once (one WARN on the transition, one INFO on recovery). Logging
297
+ * it at ERROR once per read, per read path, per poll cycle, for the whole outage, is what buries
298
+ * the errors that are actually actionable. So it drops to debug; everything else stays ERROR.
299
+ */
300
+ private logConnectFailure;
301
+ /** True while `key`'s last attempt failed — used to keep repeat attempt chatter at debug. */
302
+ private isRetryingAfterFailure;
303
+ /** Forget `key`'s failure run on a success, so the next outage logs its first failure again. */
304
+ private clearConnectFailures;
305
+ private logTransactionError;
241
306
  /**
242
307
  * Mark a unit's socket as poisoned after a timeout and reflect the hang in the shared health
243
308
  * gate immediately, so isHealthy() flips false this cycle instead of after the coarse
244
309
  * 5-failure / 5-minute-staleness thresholds. Idempotent; only logs on the first poison.
245
310
  */
246
311
  private poisonUnit;
312
+ /**
313
+ * Enter the poisoned state for a unit, logging the TRANSITION only. Everything downstream of
314
+ * this (every refused read, every poll cycle) is the same known state and must stay silent —
315
+ * one WARN in, one INFO out (see {@link logPoisonRecovery}), nothing in between.
316
+ */
317
+ private enterPoisoned;
318
+ /**
319
+ * Close out a poisoned episode on a successful (re)open: one INFO carrying how long the unit
320
+ * was refusing I/O. No-op for a unit that was never poisoned, so a normal first connect stays
321
+ * quiet.
322
+ */
323
+ private logPoisonRecovery;
247
324
  /**
248
325
  * Publicly invalidate a unit's socket so {@link isHealthy} returns false and the next
249
326
  * readData()/tryReconnect() cycle recycles it — the same effect as a timeout poison but
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
9
9
  /**
10
10
  * Current version of the enyo Energy App SDK.
11
11
  */
12
- exports.SDK_VERSION = '0.0.104';
12
+ exports.SDK_VERSION = '1.0.0';
13
13
  /**
14
14
  * Gets the current SDK version.
15
15
  * @returns The semantic version string of the SDK
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.104";
8
+ export declare const SDK_VERSION = "1.0.0";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
@@ -19,9 +19,10 @@ export interface BatteryControlsClient {
19
19
  */
20
20
  export type BatteryModificationRecorder = Pick<SnapshotService<SunspecBatteryControls>, 'recordModification'>;
21
21
  /**
22
- * Snapshot of the writable Model 124 registers taken at schedule install time
23
- * and handed back to `onRollback` when the schedule completes, is replaced, or
24
- * is restored after a process restart. JSON-serialisable because
22
+ * Snapshot of the writable Model 124 registers taken at schedule install time.
23
+ * The base library hands it back to `onRollback`, but the release path does not
24
+ * replay it — see `releaseToAuto`. It survives as the record of the installed
25
+ * `wChaMax` and the pre-schedule charge source. JSON-serialisable because
25
26
  * `EnergyAppStorage` round-trips it.
26
27
  *
27
28
  * The snapshotted `wChaMax` doubles as the denominator for the `inWRte` /
@@ -63,8 +64,9 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
63
64
  * Sticky pre-schedule snapshot, captured once on the first `onInit` and
64
65
  * held across every subsequent schedule-to-schedule replacement. Cleared
65
66
  * only when a real rollback fires (`mode: auto` from the data bus or
66
- * `dispose`). Lets the eventual restore write the *true* baseline rather
67
- * than the last-active-entry register set that the device happens to be
67
+ * `dispose`). Supplies the `wChaMax` denominator for the percentage math
68
+ * and the charge source to hand back on release — taken from the *original*
69
+ * pre-schedule read rather than the register set the device happens to be
68
70
  * in at the moment of replacement.
69
71
  */
70
72
  private originalBaseline?;
@@ -76,6 +78,11 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
76
78
  * write the snapshot back during a replacement.
77
79
  */
78
80
  private suppressNextRollbackWrite;
81
+ /**
82
+ * Mirrors the base class's private `disposed` flag so the auto-release
83
+ * path can tell "released and gone" from "released and still live".
84
+ */
85
+ private isDisposed;
79
86
  constructor(opts: SunspecBatteryScheduleHandlerOptions);
80
87
  /**
81
88
  * Override the base-class data-bus router so a schedule-to-schedule
@@ -86,9 +93,29 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
86
93
  * normally there.
87
94
  */
88
95
  applyMessage(msg: EnyoDataBusSetStorageScheduleV1): Promise<void>;
96
+ dispose(): void;
89
97
  protected onInit(_active: ActiveStorageScheduleEntry): Promise<SunspecScheduleRegisters>;
90
98
  protected onChange(active: ActiveStorageScheduleEntry, _previous: ActiveStorageScheduleEntry | undefined): void;
91
- protected onRollback(registers: SunspecScheduleRegisters): void;
99
+ protected onRollback(_registers: SunspecScheduleRegisters): void;
100
+ /**
101
+ * Hand the battery back to its own logic: clear StorCtl_Mod and open both
102
+ * rate setpoints back up to 100 %.
103
+ *
104
+ * This deliberately does *not* replay the snapshot captured at `onInit`.
105
+ * That snapshot is whatever the registers happened to hold when the
106
+ * schedule started — and if a previous schedule had already stranded a
107
+ * limit there, restoring it re-latches the limit and the battery can never
108
+ * climb out. The only correct end state for "we are no longer controlling
109
+ * this battery" is the one written here, and it is the same set of
110
+ * registers a schedule entry touches, so nothing else is left dangling.
111
+ *
112
+ * `wChaMax` is not restored because a schedule never writes it — the
113
+ * percentage math divides against it instead.
114
+ *
115
+ * @param chargeSource - `chaGriSet` to restore; falls back to PV-only,
116
+ * since grid charging is only ever switched on by a Charge entry.
117
+ */
118
+ private releaseToAuto;
92
119
  protected onError(err: Error): void;
93
120
  private applyEntry;
94
121
  }
@@ -19,8 +19,9 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
19
19
  * Sticky pre-schedule snapshot, captured once on the first `onInit` and
20
20
  * held across every subsequent schedule-to-schedule replacement. Cleared
21
21
  * only when a real rollback fires (`mode: auto` from the data bus or
22
- * `dispose`). Lets the eventual restore write the *true* baseline rather
23
- * than the last-active-entry register set that the device happens to be
22
+ * `dispose`). Supplies the `wChaMax` denominator for the percentage math
23
+ * and the charge source to hand back on release — taken from the *original*
24
+ * pre-schedule read rather than the register set the device happens to be
24
25
  * in at the moment of replacement.
25
26
  */
26
27
  originalBaseline;
@@ -32,6 +33,11 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
32
33
  * write the snapshot back during a replacement.
33
34
  */
34
35
  suppressNextRollbackWrite = false;
36
+ /**
37
+ * Mirrors the base class's private `disposed` flag so the auto-release
38
+ * path can tell "released and gone" from "released and still live".
39
+ */
40
+ isDisposed = false;
35
41
  constructor(opts) {
36
42
  super(opts);
37
43
  this.sunspecClient = opts.sunspecClient;
@@ -49,11 +55,15 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
49
55
  * normally there.
50
56
  */
51
57
  async applyMessage(msg) {
52
- if (msg.applianceId === this.applianceIdForLog
58
+ const isForThisAppliance = msg.applianceId === this.applianceIdForLog;
59
+ if (isForThisAppliance
53
60
  && msg.data.mode === EnyoStorageScheduleModeEnum.Schedule
54
61
  && this.getActiveEntry() !== undefined) {
55
62
  this.suppressNextRollbackWrite = true;
56
63
  }
64
+ // Captured before the base class runs: with a schedule active, its
65
+ // `doReleaseSchedule → onRollback` already performs the auto release.
66
+ const hadActiveSchedule = this.getActiveEntry() !== undefined;
57
67
  try {
58
68
  await super.applyMessage(msg);
59
69
  }
@@ -63,6 +73,30 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
63
73
  // otherwise stay set and silently swallow the next real rollback.
64
74
  this.suppressNextRollbackWrite = false;
65
75
  }
76
+ if (isForThisAppliance
77
+ && msg.data.mode === EnyoStorageScheduleModeEnum.Auto
78
+ && !hadActiveSchedule
79
+ && !this.isDisposed) {
80
+ // `mode: auto` with no schedule running is a no-op in the base
81
+ // library (`doReleaseSchedule` returns early when idle), so nothing
82
+ // would reach the device. That is not harmless: Model 124 setpoints
83
+ // latch — an interrupted schedule (modbus drop, package restart)
84
+ // leaves StorCtl_Mod and InWRte set, and with InOutWRte_RvrtTms = 0
85
+ // the inverter never reverts on its own. Seen in production as a
86
+ // battery pinned at ~2 % charge rate for hours while the energy
87
+ // manager sent `auto` every 40 s and got an `Accepted` back.
88
+ //
89
+ // Writing the release unconditionally is safe because it is
90
+ // idempotent: it is exactly the register set that means
91
+ // "no external control".
92
+ await this.releaseToAuto().catch(err => {
93
+ console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: auto release failed: ${err}`);
94
+ });
95
+ }
96
+ }
97
+ dispose() {
98
+ this.isDisposed = true;
99
+ super.dispose();
66
100
  }
67
101
  async onInit(_active) {
68
102
  if (this.originalBaseline !== undefined) {
@@ -101,7 +135,7 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
101
135
  console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onChange write failed for entry ${active.indexInSchedule}: ${err}`);
102
136
  });
103
137
  }
104
- onRollback(registers) {
138
+ onRollback(_registers) {
105
139
  if (this.suppressNextRollbackWrite) {
106
140
  // Schedule-to-schedule replacement. Do NOT write the snapshot
107
141
  // back; the new schedule's first `onChange` will own the
@@ -119,19 +153,41 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
119
153
  // that follows — so a concurrent `onInit` queued behind this one
120
154
  // (impossible today, but defensive) cannot observe a half-cleared
121
155
  // state.
156
+ const chargeSource = this.originalBaseline?.chaGriSet;
122
157
  this.originalBaseline = undefined;
123
158
  this.installedWChaMax = undefined;
124
- void (async () => {
125
- try {
126
- await this.sunspecClient.writeBatteryControls(this.unitId, registers);
127
- await this.getSnapshotService()?.recordModification([
128
- 'storCtlMod', 'chaGriSet', 'wChaMax', 'inWRte', 'outWRte',
129
- ]);
130
- }
131
- catch (err) {
132
- console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onRollback failed: ${err}`);
133
- }
134
- })();
159
+ void this.releaseToAuto(chargeSource).catch(err => {
160
+ console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onRollback failed: ${err}`);
161
+ });
162
+ }
163
+ /**
164
+ * Hand the battery back to its own logic: clear StorCtl_Mod and open both
165
+ * rate setpoints back up to 100 %.
166
+ *
167
+ * This deliberately does *not* replay the snapshot captured at `onInit`.
168
+ * That snapshot is whatever the registers happened to hold when the
169
+ * schedule started — and if a previous schedule had already stranded a
170
+ * limit there, restoring it re-latches the limit and the battery can never
171
+ * climb out. The only correct end state for "we are no longer controlling
172
+ * this battery" is the one written here, and it is the same set of
173
+ * registers a schedule entry touches, so nothing else is left dangling.
174
+ *
175
+ * `wChaMax` is not restored because a schedule never writes it — the
176
+ * percentage math divides against it instead.
177
+ *
178
+ * @param chargeSource - `chaGriSet` to restore; falls back to PV-only,
179
+ * since grid charging is only ever switched on by a Charge entry.
180
+ */
181
+ async releaseToAuto(chargeSource) {
182
+ await this.sunspecClient.writeBatteryControls(this.unitId, {
183
+ storCtlMod: SunspecStorageControlMode.NONE,
184
+ chaGriSet: chargeSource ?? SunspecChargeSource.PV,
185
+ inWRte: 100,
186
+ outWRte: 100,
187
+ });
188
+ await this.getSnapshotService()?.recordModification([
189
+ 'storCtlMod', 'chaGriSet', 'inWRte', 'outWRte',
190
+ ]);
135
191
  }
136
192
  onError(err) {
137
193
  this.onErrorCallback?.(err);
@@ -139,19 +195,11 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
139
195
  async applyEntry(active) {
140
196
  const { direction, powerW } = active.entry;
141
197
  if (direction === EnyoStorageScheduleDirectionEnum.Idle) {
142
- // Idle entry: hand the battery back to its own autonomous logic
143
- // by restoring the snapshotted pre-schedule registers (same write
144
- // set as the `mode: auto` rollback path). The schedule itself
145
- // keeps running, so a subsequent Charge / Discharge entry can
146
- // resume external control.
147
- const baselineRegisters = this.originalBaseline;
148
- if (!baselineRegisters) {
149
- throw new Error(`no usable baseline for idle entry (originalBaseline=undefined)`);
150
- }
151
- await this.sunspecClient.writeBatteryControls(this.unitId, baselineRegisters);
152
- await this.getSnapshotService()?.recordModification([
153
- 'storCtlMod', 'chaGriSet', 'wChaMax', 'inWRte', 'outWRte',
154
- ]);
198
+ // Idle entry: hand the battery back to its own autonomous logic —
199
+ // the same release the `mode: auto` path performs. The schedule
200
+ // itself keeps running, so a subsequent Charge / Discharge entry
201
+ // can resume external control.
202
+ await this.releaseToAuto(this.originalBaseline?.chaGriSet);
155
203
  return;
156
204
  }
157
205
  const baseline = this.installedWChaMax;
@@ -1,4 +1,4 @@
1
- import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.js";
1
+ import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, type SunspecInverterMetadataConfig, type SunspecBatteryMetadataConfig, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.js";
2
2
  import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
3
3
  import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
4
4
  import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
@@ -208,6 +208,7 @@ type SunspecPvPower = {
208
208
  export declare class SunspecInverter extends BaseSunspecDevice {
209
209
  private readonly capabilities;
210
210
  private readonly pvPowerSource;
211
+ private readonly metadataConfig;
211
212
  /** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
212
213
  private static readonly CONNECTION_FAULT_THRESHOLD;
213
214
  /**
@@ -233,7 +234,13 @@ export declare class SunspecInverter extends BaseSunspecDevice {
233
234
  private acEnergyDropStreak;
234
235
  /** Consecutive corrupt reads that confirm a genuine reset/resync (vs a transient glitch). */
235
236
  private static readonly AC_ENERGY_RESET_CONFIRM;
236
- constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource);
237
+ constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource, metadataConfig?: SunspecInverterMetadataConfig);
238
+ /**
239
+ * The consumer-supplied inverter facts, as a spreadable object that only contains the keys that
240
+ * were actually configured. Spreading `{ controlAllowed: undefined }` over an existing appliance
241
+ * would erase a value the host set elsewhere; omitting the key leaves it alone.
242
+ */
243
+ private configuredInverterMetadata;
237
244
  connect(): Promise<void>;
238
245
  disconnect(): Promise<void>;
239
246
  readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
@@ -510,6 +517,21 @@ export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryF
510
517
  /**
511
518
  * Sunspec Battery implementation
512
519
  */
520
+ /**
521
+ * Derive the storage mode from Model 124's StorCtl_Mod bitfield.
522
+ *
523
+ * The bits mark *which rate setpoint the device is enforcing* — bit 0 for
524
+ * InWRte, bit 1 for OutWRte — not which direction is permitted. So no bit set
525
+ * is the autonomous mode, and both bits set is the most externally controlled
526
+ * state there is, which is the opposite of what the naming suggests. Reading
527
+ * them the other way round meant a battery running its own logic reported
528
+ * `holding`, a fully clamped one reported `auto`, and no appliance could ever
529
+ * report that it had been handed back to itself.
530
+ *
531
+ * @param controls - Model 124 control registers, or null when unreadable.
532
+ * @returns The mode, or null when StorCtl_Mod could not be read.
533
+ */
534
+ export declare function deriveStorageMode(controls: SunspecBatteryControls | null): SunspecStorageMode | null;
513
535
  export declare class SunspecBattery extends BaseSunspecDevice {
514
536
  private readonly featureMode;
515
537
  private readonly capabilities;
@@ -532,7 +554,29 @@ export declare class SunspecBattery extends BaseSunspecDevice {
532
554
  * {@link computeAdvertisedFeatures}.
533
555
  */
534
556
  private static readonly CONTROLLABLE_FEATURES;
535
- constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
557
+ constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, metadataConfig?: SunspecBatteryMetadataConfig);
558
+ /**
559
+ * Last known round-trip efficiency, seeded from the constructor config and replaceable at
560
+ * runtime via {@link setRoundTripEfficiencyPercent}. Undefined = not yet known; the SDK then
561
+ * writes nothing, leaving whatever the appliance store already holds.
562
+ */
563
+ private roundTripEfficiencyPercent?;
564
+ /**
565
+ * Update the battery's measured round-trip efficiency (percent, 0-100) and push it to the
566
+ * appliance immediately. Meant to be called whenever the host recomputes the figure from
567
+ * completed cycles - it drifts with cell age and temperature, so a value fixed at construction
568
+ * goes stale. Pass `undefined` to stop asserting a value (the last published one stays in the
569
+ * appliance store; the SDK does not erase it).
570
+ *
571
+ * Safe to call before {@link connect}: the value is remembered and published with the rest of
572
+ * the metadata once the appliance exists.
573
+ */
574
+ setRoundTripEfficiencyPercent(percent: number | undefined): Promise<void>;
575
+ /**
576
+ * The configured battery facts as a spreadable object holding only the keys actually known.
577
+ * Spreading an explicit `undefined` would erase a value the host set elsewhere.
578
+ */
579
+ private configuredBatteryMetadata;
536
580
  /**
537
581
  * Wire the battery into `@enyo-energy/appliance-calibration`'s
538
582
  * `BatteryCalibrator` test-charge flow. Call once after {@link connect}.