This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/sunspec-devices.cjs +486 -18
- package/dist/cjs/sunspec-devices.d.cts +144 -1
- package/dist/cjs/sunspec-interfaces.d.cts +81 -0
- package/dist/cjs/sunspec-modbus-client.cjs +172 -49
- package/dist/cjs/sunspec-modbus-client.d.cts +43 -1
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-devices.d.ts +144 -1
- package/dist/sunspec-devices.js +484 -17
- package/dist/sunspec-interfaces.d.ts +81 -0
- package/dist/sunspec-modbus-client.d.ts +43 -1
- package/dist/sunspec-modbus-client.js +172 -49
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
|
@@ -216,6 +216,19 @@ export declare class SunspecModbusClient {
|
|
|
216
216
|
* 5-failure / 5-minute-staleness thresholds. Idempotent; only logs on the first poison.
|
|
217
217
|
*/
|
|
218
218
|
private poisonUnit;
|
|
219
|
+
/**
|
|
220
|
+
* Publicly invalidate a unit's socket so {@link isHealthy} returns false and the next
|
|
221
|
+
* readData()/tryReconnect() cycle recycles it — the same effect as a timeout poison but
|
|
222
|
+
* for a caller-detected fault that isn't itself a Modbus timeout.
|
|
223
|
+
*
|
|
224
|
+
* The motivating case: a TCP reconnect succeeds but the follow-up model discovery comes
|
|
225
|
+
* back empty because the gateway (e.g. a SolarEdge unit) accepted the socket before it was
|
|
226
|
+
* ready to answer the SunSpec scan. The link looks alive, so without this the reconnect
|
|
227
|
+
* would be trusted, an empty model map cached, and every subsequent read would find no
|
|
228
|
+
* model while nothing ever triggers another reconnect. Poisoning here keeps the retry
|
|
229
|
+
* schedule firing until a real discovery lands. Idempotent; only logs on the first call.
|
|
230
|
+
*/
|
|
231
|
+
invalidateUnit(unitId: number, reason: string): void;
|
|
219
232
|
/**
|
|
220
233
|
* A unit's socket is stale when the transport still reports it connected but no successful
|
|
221
234
|
* transaction has completed within staleSocketMs — the signature of a half-open link where
|
|
@@ -336,9 +349,38 @@ export declare class SunspecModbusClient {
|
|
|
336
349
|
*/
|
|
337
350
|
private extractValue;
|
|
338
351
|
/**
|
|
339
|
-
*
|
|
352
|
+
* Read a contiguous span of `quantity` registers starting at `address` in a single logical
|
|
353
|
+
* transaction — chunked at the 125-register Modbus limit and serialized on the unit's socket so no
|
|
354
|
+
* other frame interleaves between chunks. FC03 holding registers by default; FC04 input registers
|
|
355
|
+
* when `useInputRegisters` is true. The SunSpec model readers use {@link readModelBlock}; this is
|
|
356
|
+
* the equivalent for callers reading a hand-defined block (see {@link SunspecCustomDevice}). Decode
|
|
357
|
+
* individual fields out of the returned buffer with {@link decodeBlockValue}.
|
|
358
|
+
*/
|
|
359
|
+
readRegisterBlock(unitId: number, address: number, quantity: number, useInputRegisters?: boolean): Promise<Buffer>;
|
|
360
|
+
/**
|
|
361
|
+
* Decode a typed value out of a buffer returned by {@link readRegisterBlock}, at a register offset
|
|
362
|
+
* from the block start. A thin public wrapper over the same block-extraction the SunSpec model
|
|
363
|
+
* readers use internally.
|
|
364
|
+
*/
|
|
365
|
+
decodeBlockValue(buffer: Buffer, registerOffset: number, dataType: EnergyAppModbusDataType, quantity?: number): number | string | number[];
|
|
366
|
+
/**
|
|
367
|
+
* Helper to read holding register value(s) (FC03) using the fault-tolerant reader with data type
|
|
368
|
+
* conversion.
|
|
340
369
|
*/
|
|
341
370
|
readRegisterValue(unitId: number, address: number, quantity: number | undefined, dataType: EnergyAppModbusDataType): Promise<number | string | number[]>;
|
|
371
|
+
/**
|
|
372
|
+
* Helper to read input register value(s) (FC04) using the fault-tolerant reader with data type
|
|
373
|
+
* conversion. SunSpec itself never uses input registers, but plain-Modbus devices behind a
|
|
374
|
+
* {@link SunspecCustomDevice} may expose live values there. Throws if the transport's reader does
|
|
375
|
+
* not implement `readInputRegisters`.
|
|
376
|
+
*/
|
|
377
|
+
readInputRegisterValue(unitId: number, address: number, quantity: number | undefined, dataType: EnergyAppModbusDataType): Promise<number | string | number[]>;
|
|
378
|
+
/**
|
|
379
|
+
* Shared body of {@link readRegisterValue} / {@link readInputRegisterValue}. Runs the read under
|
|
380
|
+
* the unit's transaction lock (so it inherits the timeout/poison/staleness resilience) and records
|
|
381
|
+
* connection health on both success and failure.
|
|
382
|
+
*/
|
|
383
|
+
private readTypedRegisters;
|
|
342
384
|
/**
|
|
343
385
|
* Helper to write register value(s)
|
|
344
386
|
*/
|
|
@@ -574,6 +574,25 @@ export class SunspecModbusClient {
|
|
|
574
574
|
this.poisonedUnits.add(unitId);
|
|
575
575
|
this.connectionHealth.recordFailure(error);
|
|
576
576
|
}
|
|
577
|
+
/**
|
|
578
|
+
* Publicly invalidate a unit's socket so {@link isHealthy} returns false and the next
|
|
579
|
+
* readData()/tryReconnect() cycle recycles it — the same effect as a timeout poison but
|
|
580
|
+
* for a caller-detected fault that isn't itself a Modbus timeout.
|
|
581
|
+
*
|
|
582
|
+
* The motivating case: a TCP reconnect succeeds but the follow-up model discovery comes
|
|
583
|
+
* back empty because the gateway (e.g. a SolarEdge unit) accepted the socket before it was
|
|
584
|
+
* ready to answer the SunSpec scan. The link looks alive, so without this the reconnect
|
|
585
|
+
* would be trusted, an empty model map cached, and every subsequent read would find no
|
|
586
|
+
* model while nothing ever triggers another reconnect. Poisoning here keeps the retry
|
|
587
|
+
* schedule firing until a real discovery lands. Idempotent; only logs on the first call.
|
|
588
|
+
*/
|
|
589
|
+
invalidateUnit(unitId, reason) {
|
|
590
|
+
if (!this.poisonedUnits.has(unitId)) {
|
|
591
|
+
console.warn(`SunspecModbusClient: invalidating unit ${unitId} socket — ${reason}; reconnect path will recycle it`);
|
|
592
|
+
}
|
|
593
|
+
this.poisonedUnits.add(unitId);
|
|
594
|
+
this.connectionHealth.recordFailure(new Error(reason));
|
|
595
|
+
}
|
|
577
596
|
/**
|
|
578
597
|
* A unit's socket is stale when the transport still reports it connected but no successful
|
|
579
598
|
* transaction has completed within staleSocketMs — the signature of a half-open link where
|
|
@@ -682,7 +701,16 @@ export class SunspecModbusClient {
|
|
|
682
701
|
*/
|
|
683
702
|
async detectSunspecBaseAddress(unitId, customBaseAddress) {
|
|
684
703
|
const instance = this.getInstance(unitId);
|
|
685
|
-
// If custom base address provided, try it first (
|
|
704
|
+
// If a custom base address is provided, try it first (0-based, then 1-based variant).
|
|
705
|
+
//
|
|
706
|
+
// A custom base is only a real SunSpec anchor for a device whose map genuinely starts
|
|
707
|
+
// there. It is NOT an anchor when it points at a *model block* inside a shared unit —
|
|
708
|
+
// e.g. a SolarEdge meter block (~40188) co-resident with the inverter on unit 1: the
|
|
709
|
+
// "SunS" marker lives ONLY at the unit's SunSpec root (40000/40001), never at the meter
|
|
710
|
+
// block. So a miss here must NOT fail discovery; fall through to the standard root probe
|
|
711
|
+
// below. (This is exactly the reconnect path that used to strand the meter — its
|
|
712
|
+
// rediscovery threw "not SunSpec compliant" at 40188, returned no models, and poisoned
|
|
713
|
+
// the shared socket, dragging the inverter offline too.)
|
|
686
714
|
if (customBaseAddress !== undefined) {
|
|
687
715
|
console.log(`Detect models for custom base address '${customBaseAddress}' ...`);
|
|
688
716
|
// Try 0-based at custom address
|
|
@@ -715,41 +743,44 @@ export class SunspecModbusClient {
|
|
|
715
743
|
catch (error) {
|
|
716
744
|
console.debug(`Could not read SunS at ${customBaseAddress + 1}:`, error);
|
|
717
745
|
}
|
|
746
|
+
console.debug(`No "SunS" marker at custom base ${customBaseAddress}/${customBaseAddress + 1} on unit ${unitId} — ` +
|
|
747
|
+
`falling back to the standard SunSpec root (40001/40000). Expected when the custom base points at a ` +
|
|
748
|
+
`model block inside a shared unit (e.g. a co-resident meter), whose anchor is the unit root.`);
|
|
718
749
|
}
|
|
719
|
-
|
|
720
|
-
|
|
721
|
-
|
|
722
|
-
|
|
723
|
-
|
|
724
|
-
|
|
725
|
-
|
|
726
|
-
|
|
727
|
-
|
|
728
|
-
|
|
729
|
-
|
|
730
|
-
}
|
|
731
|
-
}
|
|
732
|
-
catch (error) {
|
|
733
|
-
console.debug('Could not read SunS at 40001:', error);
|
|
734
|
-
}
|
|
735
|
-
// Try 0-based addressing
|
|
736
|
-
try {
|
|
737
|
-
const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40000, 2));
|
|
738
|
-
if (sunspecId.includes('SunS')) {
|
|
739
|
-
console.log('Detected 0-based addressing mode (base address: 40000)');
|
|
740
|
-
return {
|
|
741
|
-
baseAddress: 40000,
|
|
742
|
-
isZeroBased: true,
|
|
743
|
-
nextAddress: 40002
|
|
744
|
-
};
|
|
745
|
-
}
|
|
750
|
+
// Standard SunSpec root probe. Runs when no custom base was given, OR as the fallback
|
|
751
|
+
// when the custom base carried no marker. Try 1-based (40001) first (most common), then
|
|
752
|
+
// 0-based (40000).
|
|
753
|
+
try {
|
|
754
|
+
const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40001, 2));
|
|
755
|
+
if (sunspecId.includes('SunS')) {
|
|
756
|
+
console.log('Detected 1-based addressing mode (base address: 40001)');
|
|
757
|
+
return {
|
|
758
|
+
baseAddress: 40001,
|
|
759
|
+
isZeroBased: false,
|
|
760
|
+
nextAddress: 40003
|
|
761
|
+
};
|
|
746
762
|
}
|
|
747
|
-
|
|
748
|
-
|
|
763
|
+
}
|
|
764
|
+
catch (error) {
|
|
765
|
+
console.debug('Could not read SunS at 40001:', error);
|
|
766
|
+
}
|
|
767
|
+
// Try 0-based addressing
|
|
768
|
+
try {
|
|
769
|
+
const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40000, 2));
|
|
770
|
+
if (sunspecId.includes('SunS')) {
|
|
771
|
+
console.log('Detected 0-based addressing mode (base address: 40000)');
|
|
772
|
+
return {
|
|
773
|
+
baseAddress: 40000,
|
|
774
|
+
isZeroBased: true,
|
|
775
|
+
nextAddress: 40002
|
|
776
|
+
};
|
|
749
777
|
}
|
|
750
778
|
}
|
|
779
|
+
catch (error) {
|
|
780
|
+
console.debug('Could not read SunS at 40000:', error);
|
|
781
|
+
}
|
|
751
782
|
const addressesChecked = customBaseAddress !== undefined
|
|
752
|
-
? `${customBaseAddress}, ${customBaseAddress + 1}`
|
|
783
|
+
? `${customBaseAddress}, ${customBaseAddress + 1}, 40001, 40000`
|
|
753
784
|
: '40000 or 40001';
|
|
754
785
|
throw new Error(`Device is not SunSpec compliant - "SunS" identifier not found at addresses ${addressesChecked}`);
|
|
755
786
|
}
|
|
@@ -760,29 +791,35 @@ export class SunspecModbusClient {
|
|
|
760
791
|
async discoverModels(unitId, customBaseAddress) {
|
|
761
792
|
const instance = this.getInstance(unitId);
|
|
762
793
|
const models = this.getModelsMap(unitId);
|
|
763
|
-
models.clear();
|
|
764
794
|
const modelList = this.getModelList(unitId);
|
|
765
|
-
modelList.length = 0;
|
|
766
795
|
const maxAddress = 50000; // Safety limit
|
|
767
|
-
let currentAddress = 0;
|
|
768
796
|
console.log(`Starting Sunspec model discovery for unit ${unitId}...`);
|
|
769
797
|
// Probe for the SunS identifier first. A missing identifier means the unit ID isn't a
|
|
770
798
|
// SunSpec device — common during unit-ID scans — and is logged at debug level so probes
|
|
771
799
|
// don't surface as errors. Mid-scan failures below remain at error level since they
|
|
772
800
|
// indicate a partial / malformed SunSpec map.
|
|
801
|
+
//
|
|
802
|
+
// IMPORTANT: we discover into TEMP buffers and only commit into the stored map once the
|
|
803
|
+
// walk yields at least one model. A reconnect probe can transiently fail (e.g. a single-
|
|
804
|
+
// session SolarEdge endpoint drops the socket with ECONNRESET on the first read after
|
|
805
|
+
// accepting the connection). Clearing the stored map up-front — as this used to — turned
|
|
806
|
+
// that blip into "no usable models", which trips tryReconnect()'s gate into invalidating
|
|
807
|
+
// a unit whose model map was perfectly good a moment ago. Preserving the last known-good
|
|
808
|
+
// map keeps a genuinely-connected sibling alive; a device that is really gone is still
|
|
809
|
+
// caught by read-health (isHealthy()).
|
|
773
810
|
let addressInfo;
|
|
774
811
|
try {
|
|
775
812
|
addressInfo = await this.detectSunspecBaseAddress(unitId, customBaseAddress);
|
|
776
813
|
}
|
|
777
814
|
catch (error) {
|
|
778
815
|
console.debug(`No SunSpec device at unit ${unitId}: ${error}`);
|
|
779
|
-
//
|
|
780
|
-
//
|
|
781
|
-
|
|
782
|
-
console.debug(`Discovery complete for unit ${unitId}. Found 0 models: []`);
|
|
816
|
+
// Same outcome as a normal "no device found"; keep at debug. Do NOT wipe the stored
|
|
817
|
+
// map — return it untouched so a transient probe failure can't erase good discovery.
|
|
818
|
+
console.debug(`Discovery incomplete for unit ${unitId}; keeping ${models.size} previously-discovered model(s).`);
|
|
783
819
|
return models;
|
|
784
820
|
}
|
|
785
|
-
|
|
821
|
+
const discovered = [];
|
|
822
|
+
let currentAddress = addressInfo.nextAddress;
|
|
786
823
|
try {
|
|
787
824
|
while (currentAddress < maxAddress) {
|
|
788
825
|
const buffer = await this.runExclusive(unitId, () => instance.readHoldingRegisters(currentAddress, 2));
|
|
@@ -798,19 +835,12 @@ export class SunspecModbusClient {
|
|
|
798
835
|
console.debug(`Found end marker at address ${currentAddress}`);
|
|
799
836
|
break;
|
|
800
837
|
}
|
|
801
|
-
// Store discovered model
|
|
802
838
|
const model = {
|
|
803
839
|
id: modelId,
|
|
804
840
|
address: currentAddress,
|
|
805
841
|
length: modelLength
|
|
806
842
|
};
|
|
807
|
-
|
|
808
|
-
// findModel() resolves to the device's own block. Record every instance —
|
|
809
|
-
// including repeats like a meter's Common (id 1) — in the ordered list.
|
|
810
|
-
if (!models.has(modelId)) {
|
|
811
|
-
models.set(modelId, model);
|
|
812
|
-
}
|
|
813
|
-
modelList.push(model);
|
|
843
|
+
discovered.push(model);
|
|
814
844
|
// Per-model discovery step. The end-of-discovery summary below is the
|
|
815
845
|
// info-level outcome; the per-model walk is debug-only.
|
|
816
846
|
console.debug(`Discovered Model ${modelId} at address ${currentAddress} with length ${modelLength} (unit ${unitId})`);
|
|
@@ -821,6 +851,24 @@ export class SunspecModbusClient {
|
|
|
821
851
|
catch (error) {
|
|
822
852
|
console.error(`Error during model discovery at address ${currentAddress} (unit ${unitId}): ${error}`);
|
|
823
853
|
}
|
|
854
|
+
if (discovered.length > 0) {
|
|
855
|
+
// Commit the fresh discovery atomically. Keep the FIRST (lowest-address) instance per
|
|
856
|
+
// id in the keyed directory so findModel() resolves to the device's own block; record
|
|
857
|
+
// every instance — including repeats like a meter's Common (id 1) — in the ordered list.
|
|
858
|
+
models.clear();
|
|
859
|
+
modelList.length = 0;
|
|
860
|
+
for (const model of discovered) {
|
|
861
|
+
if (!models.has(model.id)) {
|
|
862
|
+
models.set(model.id, model);
|
|
863
|
+
}
|
|
864
|
+
modelList.push(model);
|
|
865
|
+
}
|
|
866
|
+
}
|
|
867
|
+
else {
|
|
868
|
+
// The anchor answered but the walk yielded nothing (e.g. the socket dropped right
|
|
869
|
+
// after the SunS probe). Preserve the last known-good map rather than clobbering it.
|
|
870
|
+
console.debug(`Discovery for unit ${unitId} yielded no models; keeping ${models.size} previously-discovered model(s).`);
|
|
871
|
+
}
|
|
824
872
|
// Report every instance in address order so repeated ids (e.g. two Common blocks, or
|
|
825
873
|
// multiple meters) are visible — models.size would hide them behind the unique keys.
|
|
826
874
|
console.log(`Discovery complete for unit ${unitId}. Found ${modelList.length} model instance(s): [${modelList.map(m => m.id).join(', ')}]`);
|
|
@@ -962,12 +1010,87 @@ export class SunspecModbusClient {
|
|
|
962
1010
|
return value;
|
|
963
1011
|
}
|
|
964
1012
|
/**
|
|
965
|
-
*
|
|
1013
|
+
* Read a contiguous span of `quantity` registers starting at `address` in a single logical
|
|
1014
|
+
* transaction — chunked at the 125-register Modbus limit and serialized on the unit's socket so no
|
|
1015
|
+
* other frame interleaves between chunks. FC03 holding registers by default; FC04 input registers
|
|
1016
|
+
* when `useInputRegisters` is true. The SunSpec model readers use {@link readModelBlock}; this is
|
|
1017
|
+
* the equivalent for callers reading a hand-defined block (see {@link SunspecCustomDevice}). Decode
|
|
1018
|
+
* individual fields out of the returned buffer with {@link decodeBlockValue}.
|
|
1019
|
+
*/
|
|
1020
|
+
async readRegisterBlock(unitId, address, quantity, useInputRegisters = false) {
|
|
1021
|
+
const reader = this.getReader(unitId);
|
|
1022
|
+
const MAX_REGISTERS_PER_READ = 125;
|
|
1023
|
+
try {
|
|
1024
|
+
const chunks = await this.runExclusive(unitId, async () => {
|
|
1025
|
+
const acc = [];
|
|
1026
|
+
for (let offset = 0; offset < quantity; offset += MAX_REGISTERS_PER_READ) {
|
|
1027
|
+
const count = Math.min(MAX_REGISTERS_PER_READ, quantity - offset);
|
|
1028
|
+
let result;
|
|
1029
|
+
if (useInputRegisters) {
|
|
1030
|
+
if (!reader.readInputRegisters) {
|
|
1031
|
+
throw new Error(`Reader for unit ${unitId} does not support FC04 input registers`);
|
|
1032
|
+
}
|
|
1033
|
+
result = await reader.readInputRegisters(address + offset, count);
|
|
1034
|
+
}
|
|
1035
|
+
else {
|
|
1036
|
+
result = await reader.readHoldingRegisters(address + offset, count);
|
|
1037
|
+
}
|
|
1038
|
+
if (!result.success || !result.value) {
|
|
1039
|
+
throw new Error(`Failed to read register block at address ${address + offset} (unit ${unitId}): ${result.error?.message || 'Unknown error'}`);
|
|
1040
|
+
}
|
|
1041
|
+
acc.push(result.value);
|
|
1042
|
+
}
|
|
1043
|
+
return acc;
|
|
1044
|
+
});
|
|
1045
|
+
this.connectionHealth.recordSuccess();
|
|
1046
|
+
return chunks.length === 1 ? chunks[0] : Buffer.concat(chunks);
|
|
1047
|
+
}
|
|
1048
|
+
catch (error) {
|
|
1049
|
+
this.connectionHealth.recordFailure(error);
|
|
1050
|
+
throw error;
|
|
1051
|
+
}
|
|
1052
|
+
}
|
|
1053
|
+
/**
|
|
1054
|
+
* Decode a typed value out of a buffer returned by {@link readRegisterBlock}, at a register offset
|
|
1055
|
+
* from the block start. A thin public wrapper over the same block-extraction the SunSpec model
|
|
1056
|
+
* readers use internally.
|
|
1057
|
+
*/
|
|
1058
|
+
decodeBlockValue(buffer, registerOffset, dataType, quantity = 1) {
|
|
1059
|
+
return this.extractValue(buffer, registerOffset, dataType, quantity);
|
|
1060
|
+
}
|
|
1061
|
+
/**
|
|
1062
|
+
* Helper to read holding register value(s) (FC03) using the fault-tolerant reader with data type
|
|
1063
|
+
* conversion.
|
|
966
1064
|
*/
|
|
967
1065
|
async readRegisterValue(unitId, address, quantity = 1, dataType) {
|
|
1066
|
+
return this.readTypedRegisters(unitId, address, quantity, dataType, false);
|
|
1067
|
+
}
|
|
1068
|
+
/**
|
|
1069
|
+
* Helper to read input register value(s) (FC04) using the fault-tolerant reader with data type
|
|
1070
|
+
* conversion. SunSpec itself never uses input registers, but plain-Modbus devices behind a
|
|
1071
|
+
* {@link SunspecCustomDevice} may expose live values there. Throws if the transport's reader does
|
|
1072
|
+
* not implement `readInputRegisters`.
|
|
1073
|
+
*/
|
|
1074
|
+
async readInputRegisterValue(unitId, address, quantity = 1, dataType) {
|
|
1075
|
+
return this.readTypedRegisters(unitId, address, quantity, dataType, true);
|
|
1076
|
+
}
|
|
1077
|
+
/**
|
|
1078
|
+
* Shared body of {@link readRegisterValue} / {@link readInputRegisterValue}. Runs the read under
|
|
1079
|
+
* the unit's transaction lock (so it inherits the timeout/poison/staleness resilience) and records
|
|
1080
|
+
* connection health on both success and failure.
|
|
1081
|
+
*/
|
|
1082
|
+
async readTypedRegisters(unitId, address, quantity, dataType, useInputRegisters) {
|
|
968
1083
|
const reader = this.getReader(unitId);
|
|
969
1084
|
try {
|
|
970
|
-
const result = await this.runExclusive(unitId, () =>
|
|
1085
|
+
const result = await this.runExclusive(unitId, () => {
|
|
1086
|
+
if (useInputRegisters) {
|
|
1087
|
+
if (!reader.readInputRegisters) {
|
|
1088
|
+
throw new Error(`Reader for unit ${unitId} does not support FC04 input registers`);
|
|
1089
|
+
}
|
|
1090
|
+
return reader.readInputRegisters(address, quantity);
|
|
1091
|
+
}
|
|
1092
|
+
return reader.readHoldingRegisters(address, quantity);
|
|
1093
|
+
});
|
|
971
1094
|
// Check if the read was successful
|
|
972
1095
|
if (!result.success || !result.value) {
|
|
973
1096
|
throw new Error(`Failed to read register at address ${address}: ${result.error?.message || 'Unknown error'}`);
|
package/dist/version.d.ts
CHANGED
package/dist/version.js
CHANGED
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@enyo-energy/sunspec-sdk",
|
|
3
|
-
"version": "0.0.
|
|
3
|
+
"version": "0.0.102",
|
|
4
4
|
"description": "enyo Energy Sunspec SDK",
|
|
5
5
|
"type": "module",
|
|
6
6
|
"main": "dist/index.js",
|
|
@@ -41,7 +41,7 @@
|
|
|
41
41
|
},
|
|
42
42
|
"dependencies": {
|
|
43
43
|
"@enyo-energy/appliance-calibration": "0.0.2",
|
|
44
|
-
"@enyo-energy/energy-app-sdk": "^0.0.
|
|
44
|
+
"@enyo-energy/energy-app-sdk": "^0.0.177"
|
|
45
45
|
},
|
|
46
46
|
"volta": {
|
|
47
47
|
"node": "22.17.0"
|