@enyo-energy/sunspec-sdk 0.0.100 → 0.0.102
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/sunspec-devices.cjs +486 -18
- package/dist/cjs/sunspec-devices.d.cts +144 -1
- package/dist/cjs/sunspec-interfaces.d.cts +81 -0
- package/dist/cjs/sunspec-modbus-client.cjs +172 -49
- package/dist/cjs/sunspec-modbus-client.d.cts +43 -1
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-devices.d.ts +144 -1
- package/dist/sunspec-devices.js +484 -17
- package/dist/sunspec-interfaces.d.ts +81 -0
- package/dist/sunspec-modbus-client.d.ts +43 -1
- package/dist/sunspec-modbus-client.js +172 -49
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.cjs";
|
|
1
|
+
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.cjs";
|
|
2
2
|
import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
3
3
|
import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
|
|
@@ -68,12 +68,55 @@ export declare abstract class BaseSunspecDevice {
|
|
|
68
68
|
* Ensure the Sunspec client is connected and models are discovered
|
|
69
69
|
*/
|
|
70
70
|
protected ensureConnected(): Promise<void>;
|
|
71
|
+
/**
|
|
72
|
+
* Populate the per-unit model directory after the socket opens. Default: run SunSpec model
|
|
73
|
+
* discovery. Devices that read a hand-defined static register map instead of a discovered SunSpec
|
|
74
|
+
* directory (see {@link SunspecCustomDevice}) override this to a no-op.
|
|
75
|
+
*/
|
|
76
|
+
protected discoverAfterConnect(): Promise<void>;
|
|
77
|
+
/**
|
|
78
|
+
* Validate that a just-completed reconnect actually restored a usable device. Default: re-run
|
|
79
|
+
* SunSpec discovery and check it against {@link getRequiredModelIds} (a socket that opens but comes
|
|
80
|
+
* back with no usable models means the gateway accepted the connection before it was ready to
|
|
81
|
+
* answer the scan). Returns false to treat the reconnect as failed so the backoff schedule keeps
|
|
82
|
+
* running. Discovery-less devices override this to just confirm the socket is open.
|
|
83
|
+
*/
|
|
84
|
+
protected revalidateAfterReconnect(): Promise<boolean>;
|
|
71
85
|
/**
|
|
72
86
|
* Attempt a reconnection if the tiered retry schedule allows it.
|
|
73
87
|
* Called from readData() when the device is disconnected.
|
|
74
88
|
* Returns true if reconnection succeeded.
|
|
75
89
|
*/
|
|
76
90
|
protected tryReconnect(): Promise<boolean>;
|
|
91
|
+
/**
|
|
92
|
+
* Model IDs this device needs to produce a reading; presence of ANY one means a
|
|
93
|
+
* discovery is usable (one-of semantics — devices expose mutually-exclusive
|
|
94
|
+
* encoding/phase variants, e.g. int+SF vs float, single- vs three-phase). Empty
|
|
95
|
+
* (the base default) means no specific requirement, so any model present
|
|
96
|
+
* suffices. Concrete devices override with their acceptable set — this is the
|
|
97
|
+
* single per-device source of truth reused by both the reconnect discovery gate
|
|
98
|
+
* ({@link isDiscoveryUsable}) and the connect-time presence gate
|
|
99
|
+
* ({@link hasRequiredModels}).
|
|
100
|
+
*/
|
|
101
|
+
protected getRequiredModelIds(): readonly number[];
|
|
102
|
+
/**
|
|
103
|
+
* True if the current per-unit discovered-model map satisfies this device's
|
|
104
|
+
* requirement. The connect-time twin of {@link isDiscoveryUsable}: it inspects
|
|
105
|
+
* the already-populated map via findModel() rather than a freshly-returned one.
|
|
106
|
+
* Only meaningful for devices that declare a non-empty required set.
|
|
107
|
+
*/
|
|
108
|
+
protected hasRequiredModels(): boolean;
|
|
109
|
+
/**
|
|
110
|
+
* Decide whether a post-reconnect model discovery is usable. A reconnect that
|
|
111
|
+
* establishes the TCP socket but comes back empty (or with only a Common block)
|
|
112
|
+
* means the device accepted the connection before it was ready to answer the
|
|
113
|
+
* SunSpec scan; the discovered-model map is now missing this device's data
|
|
114
|
+
* model, so trusting the reconnect would leave every read finding no model.
|
|
115
|
+
* Validated generically against {@link getRequiredModelIds}: with a declared
|
|
116
|
+
* set, at least one of those ids must be present; with none declared, fall back
|
|
117
|
+
* to "any model present".
|
|
118
|
+
*/
|
|
119
|
+
protected isDiscoveryUsable(models: Map<number, SunspecModel>): boolean;
|
|
77
120
|
/**
|
|
78
121
|
* Hook for subclasses to react to a failed reconnect attempt. Called once
|
|
79
122
|
* per failed attempt with the running consecutive-failure count.
|
|
@@ -142,6 +185,13 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
142
185
|
private readonly pvPowerSource;
|
|
143
186
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
144
187
|
private static readonly CONNECTION_FAULT_THRESHOLD;
|
|
188
|
+
/**
|
|
189
|
+
* The inverter data models this device can read (int+SF 101/103 and IEEE-754
|
|
190
|
+
* float 111/112/113). A post-reconnect discovery that finds none of these has
|
|
191
|
+
* not really recovered the inverter, so {@link isDiscoveryUsable} rejects it —
|
|
192
|
+
* see the override below.
|
|
193
|
+
*/
|
|
194
|
+
private static readonly INVERTER_MODEL_IDS;
|
|
145
195
|
/**
|
|
146
196
|
* Require this many consecutive operatingState=7 (FAULT) reads before
|
|
147
197
|
* reporting Faulted. Debounces transient single-poll FAULT reads (e.g. a
|
|
@@ -218,6 +268,14 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
218
268
|
private hasErrorSetChanged;
|
|
219
269
|
private buildStatusMessage;
|
|
220
270
|
private detectAndEmitStatusTransition;
|
|
271
|
+
/**
|
|
272
|
+
* A reconnect has only recovered the inverter if discovery finds one of its
|
|
273
|
+
* data models. An SE gateway can accept the new socket and answer a partial
|
|
274
|
+
* scan (e.g. only the Common block) before the inverter map is ready — the
|
|
275
|
+
* base size>0 rule would accept that, but every inverter read would then find
|
|
276
|
+
* no 101/103/111/112/113 model and report 0 W. Require an actual inverter model.
|
|
277
|
+
*/
|
|
278
|
+
protected getRequiredModelIds(): readonly number[];
|
|
221
279
|
protected onConnectionFailure(consecutiveFailures: number): Promise<void>;
|
|
222
280
|
protected onConnectionRestored(): Promise<void>;
|
|
223
281
|
/**
|
|
@@ -430,6 +488,13 @@ export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryF
|
|
|
430
488
|
export declare class SunspecBattery extends BaseSunspecDevice {
|
|
431
489
|
private readonly featureMode;
|
|
432
490
|
private readonly capabilities;
|
|
491
|
+
/**
|
|
492
|
+
* Battery data models this device can read: Battery (124, full decode) and
|
|
493
|
+
* BatteryBase (802, derived decode). BatteryControl (803) is intentionally
|
|
494
|
+
* excluded — it is a decode stub that yields no telemetry — so a rediscovery
|
|
495
|
+
* that returns only 803 is treated as unrecovered, matching the connect() gate.
|
|
496
|
+
*/
|
|
497
|
+
private static readonly BATTERY_MODEL_IDS;
|
|
433
498
|
private snapshotService?;
|
|
434
499
|
private calibrationDriver?;
|
|
435
500
|
private batteryCalibrator?;
|
|
@@ -478,6 +543,7 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
478
543
|
* `CalibrationTrigger`.
|
|
479
544
|
*/
|
|
480
545
|
getBatteryCalibrator(): BatteryCalibrator<SunspecBatteryControls> | undefined;
|
|
546
|
+
protected getRequiredModelIds(): readonly number[];
|
|
481
547
|
/**
|
|
482
548
|
* Connect to the battery and create/update the appliance
|
|
483
549
|
*/
|
|
@@ -646,6 +712,12 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
646
712
|
*/
|
|
647
713
|
export declare class SunspecMeter extends BaseSunspecDevice {
|
|
648
714
|
private readonly capabilities;
|
|
715
|
+
/**
|
|
716
|
+
* Meter data models this device can read, across int+SF (201/203/204) and
|
|
717
|
+
* IEEE-754 float (211/212/213/214) encodings and single/split/three-phase
|
|
718
|
+
* variants. Used when the meter is not bound to a specific instance.
|
|
719
|
+
*/
|
|
720
|
+
private static readonly METER_MODEL_IDS;
|
|
649
721
|
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecMeterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
|
|
650
722
|
/**
|
|
651
723
|
* The specific meter model instance this meter reads, when its unit hosts more than one
|
|
@@ -659,6 +731,11 @@ export declare class SunspecMeter extends BaseSunspecDevice {
|
|
|
659
731
|
* {@link SunspecModbusClient.findModels}). Call before {@link connect}.
|
|
660
732
|
*/
|
|
661
733
|
bindMeterModel(model: SunspecModel): void;
|
|
734
|
+
/**
|
|
735
|
+
* A bound meter requires ITS own pinned model id to reappear after a
|
|
736
|
+
* rediscovery; an unbound meter accepts any meter model on its unit.
|
|
737
|
+
*/
|
|
738
|
+
protected getRequiredModelIds(): readonly number[];
|
|
662
739
|
/**
|
|
663
740
|
* Connect to the meter and create/update the appliance
|
|
664
741
|
*/
|
|
@@ -672,4 +749,70 @@ export declare class SunspecMeter extends BaseSunspecDevice {
|
|
|
672
749
|
*/
|
|
673
750
|
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
674
751
|
}
|
|
752
|
+
/**
|
|
753
|
+
* A generic, pre-configured Modbus device that plugs into the exact same resilient lifecycle as the
|
|
754
|
+
* SunSpec devices — the per-device {@link ConnectionRetryManager}, {@link tryReconnect} tiered backoff,
|
|
755
|
+
* {@link markOffline}/{@link reassertConnectedIfRecovered} shared-socket healing, and the client's
|
|
756
|
+
* per-transaction timeout/poison/staleness guards — but reads a **hand-defined static register map**
|
|
757
|
+
* instead of a discovered SunSpec model directory.
|
|
758
|
+
*
|
|
759
|
+
* It emulates a configurable {@link SunspecCustomDeviceConfig.role} (`meter` | `inverter` | `battery`):
|
|
760
|
+
* the role selects the appliance type created on connect and which EnyoDataBus values message
|
|
761
|
+
* {@link readData} publishes, and each {@link SunspecCustomRegister} maps onto one numeric field of
|
|
762
|
+
* that message. Supports FC03 holding registers (default), FC04 input registers, and writes.
|
|
763
|
+
*
|
|
764
|
+
* Discovery is fully bypassed: {@link connect} opens the socket only, and the reconnect path is
|
|
765
|
+
* validated by socket liveness rather than a SunSpec scan.
|
|
766
|
+
*/
|
|
767
|
+
export declare class SunspecCustomDevice extends BaseSunspecDevice {
|
|
768
|
+
private readonly config;
|
|
769
|
+
/** Read plan derived once from the static register map (see {@link planBlocks}). */
|
|
770
|
+
private plannedBlocks?;
|
|
771
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, config: SunspecCustomDeviceConfig, unitId?: number, port?: number, baseAddress?: number, retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
|
|
772
|
+
/**
|
|
773
|
+
* No SunSpec model directory to build — this device reads pre-defined static addresses. Overriding
|
|
774
|
+
* the base discovery hook to a no-op is what lets {@link ensureConnected}/{@link connect} open the
|
|
775
|
+
* socket without a SunS scan.
|
|
776
|
+
*/
|
|
777
|
+
protected discoverAfterConnect(): Promise<void>;
|
|
778
|
+
/**
|
|
779
|
+
* A reconnect is usable as soon as the socket is open again — there is no model map to revalidate.
|
|
780
|
+
* Without this override the base default would run SunSpec discovery, find nothing, and treat every
|
|
781
|
+
* reconnect as a permanent failure.
|
|
782
|
+
*/
|
|
783
|
+
protected revalidateAfterReconnect(): Promise<boolean>;
|
|
784
|
+
/**
|
|
785
|
+
* Connect the underlying socket (no discovery) and create/update the appliance for the configured
|
|
786
|
+
* role. Identity metadata comes from {@link SunspecCustomDeviceConfig.identity} since there is no
|
|
787
|
+
* SunSpec Common block to read it from.
|
|
788
|
+
*/
|
|
789
|
+
connect(): Promise<void>;
|
|
790
|
+
disconnect(): Promise<void>;
|
|
791
|
+
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
792
|
+
/**
|
|
793
|
+
* Write a value to a pre-configured writable register. Delegates to the client's resilient
|
|
794
|
+
* {@link SunspecModbusClient.writeRegisterValue}.
|
|
795
|
+
*/
|
|
796
|
+
writeCustomRegister(name: string, value: number | number[]): Promise<boolean>;
|
|
797
|
+
/**
|
|
798
|
+
* Read every configured register as a small number of block reads and extract each register from
|
|
799
|
+
* its block buffer by offset (mirroring the SunSpec model-block read). Applies the fixed decimal
|
|
800
|
+
* scaling and returns a field → value map. Non-numeric reads (e.g. a `string` dataType that can't
|
|
801
|
+
* populate a numeric databus field) are skipped with a warning.
|
|
802
|
+
*/
|
|
803
|
+
private readConfiguredRegisters;
|
|
804
|
+
/** Lazily compute and cache the block read plan; the register map is static per device. */
|
|
805
|
+
private getPlannedBlocks;
|
|
806
|
+
/**
|
|
807
|
+
* Group the configured registers (separately per function code) sorted by address, coalescing them
|
|
808
|
+
* — across gaps — into blocks no wider than {@link SunspecCustomDeviceConfig.blockSize}. A new block
|
|
809
|
+
* starts whenever adding the next register would exceed that span. Each block records its members'
|
|
810
|
+
* offsets so a single read can be sliced into all of them.
|
|
811
|
+
*/
|
|
812
|
+
private planBlocks;
|
|
813
|
+
private buildRoleMessage;
|
|
814
|
+
private buildMeterMessage;
|
|
815
|
+
private buildInverterMessage;
|
|
816
|
+
private buildBatteryMessage;
|
|
817
|
+
}
|
|
675
818
|
export {};
|
|
@@ -3,6 +3,7 @@
|
|
|
3
3
|
*/
|
|
4
4
|
import { EnyoBatteryFeature } from "@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js";
|
|
5
5
|
import { EnyoBatteryStateEnum, EnyoDataBusInverterValuesV1String, EnyoInverterStateEnum } from "@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js";
|
|
6
|
+
import { EnergyAppModbusDataType } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/interfaces.js";
|
|
6
7
|
/**
|
|
7
8
|
* A single phase in the tiered retry schedule
|
|
8
9
|
*/
|
|
@@ -98,6 +99,86 @@ export interface IModbusResilienceConfig {
|
|
|
98
99
|
connectRetryDelayMs?: number;
|
|
99
100
|
}
|
|
100
101
|
export declare const DEFAULT_MODBUS_RESILIENCE_CONFIG: Required<IModbusResilienceConfig>;
|
|
102
|
+
/**
|
|
103
|
+
* The appliance role a {@link SunspecCustomDeviceConfig} emulates. Selects the appliance type created
|
|
104
|
+
* on connect and which EnyoDataBus values message {@link SunspecCustomDevice.readData} publishes.
|
|
105
|
+
*/
|
|
106
|
+
export type SunspecCustomDeviceRole = 'meter' | 'inverter' | 'battery';
|
|
107
|
+
/**
|
|
108
|
+
* A single pre-defined register a {@link SunspecCustomDevice} reads each poll. Unlike the SunSpec
|
|
109
|
+
* model readers, there is no discovery, scale-factor register, or NOT_IMPLEMENTED sentinel handling:
|
|
110
|
+
* the caller supplies the exact address, type and (optional) fixed scaling for a plain-Modbus device.
|
|
111
|
+
*/
|
|
112
|
+
export interface SunspecCustomRegister {
|
|
113
|
+
/**
|
|
114
|
+
* The databus data-field this register populates for the configured role (e.g. `gridPowerW` for a
|
|
115
|
+
* meter, `pvPowerW` for an inverter, `batterySoC` for a battery). Validated against the role's
|
|
116
|
+
* numeric field set at read time; unknown fields are ignored with a warning.
|
|
117
|
+
*/
|
|
118
|
+
field: string;
|
|
119
|
+
/** Modbus register address (absolute). */
|
|
120
|
+
address: number;
|
|
121
|
+
/** How to decode the raw registers. */
|
|
122
|
+
dataType: EnergyAppModbusDataType;
|
|
123
|
+
/** Registers to read. Defaults to the natural width of {@link dataType} (1 for 16-bit, 2 for 32-bit). */
|
|
124
|
+
quantity?: number;
|
|
125
|
+
/** Fixed decimal scaling applied as `value * 10^scaleFactor`. Default 0 (no scaling). */
|
|
126
|
+
scaleFactor?: number;
|
|
127
|
+
/** Modbus function code: 3 = holding registers (default), 4 = input registers. */
|
|
128
|
+
functionCode?: 3 | 4;
|
|
129
|
+
}
|
|
130
|
+
/**
|
|
131
|
+
* A writable register exposed through {@link SunspecCustomDevice.writeCustomRegister}. Limited to the
|
|
132
|
+
* data types the client's {@link writeRegisterValue} can serialize (uint16/int16/uint32/int32).
|
|
133
|
+
*/
|
|
134
|
+
export interface SunspecCustomWriteRegister {
|
|
135
|
+
/** Caller-facing handle passed to `writeCustomRegister(name, value)`. */
|
|
136
|
+
name: string;
|
|
137
|
+
/** Modbus register address (absolute). */
|
|
138
|
+
address: number;
|
|
139
|
+
/** How to serialize the value. */
|
|
140
|
+
dataType: EnergyAppModbusDataType;
|
|
141
|
+
}
|
|
142
|
+
/**
|
|
143
|
+
* Declarative configuration for a {@link SunspecCustomDevice}: a plain-Modbus device polled through
|
|
144
|
+
* the SDK's resilient connection management but read from a hand-defined static register map rather
|
|
145
|
+
* than a discovered SunSpec model directory.
|
|
146
|
+
*/
|
|
147
|
+
export interface SunspecCustomDeviceConfig {
|
|
148
|
+
/** Which appliance role to emulate (drives appliance type + emitted databus message). */
|
|
149
|
+
role: SunspecCustomDeviceRole;
|
|
150
|
+
/** The static registers read every poll and mapped onto the role's databus message. */
|
|
151
|
+
registers: SunspecCustomRegister[];
|
|
152
|
+
/**
|
|
153
|
+
* Maximum registers spanned by a single block read. Registers (grouped per function code) are
|
|
154
|
+
* sorted by address and coalesced — across gaps — into as few reads as possible, each spanning at
|
|
155
|
+
* most this many registers; every register is then sliced out of its block buffer by offset, just
|
|
156
|
+
* like a SunSpec model block. Larger blocks mean fewer round-trips but read any unmapped registers
|
|
157
|
+
* in the gaps (which some devices reject). Default 125 (the Modbus FC03/FC04 per-read limit); a
|
|
158
|
+
* block wider than 125 is still chunked internally.
|
|
159
|
+
*/
|
|
160
|
+
blockSize?: number;
|
|
161
|
+
/** Optional writable registers exposed via `writeCustomRegister`. */
|
|
162
|
+
writeRegisters?: SunspecCustomWriteRegister[];
|
|
163
|
+
/**
|
|
164
|
+
* Static operating state to publish for the `inverter` role. Without SunSpec status models there is
|
|
165
|
+
* no register to derive it from, so callers may pin one (e.g. `Mppt`). Ignored for other roles.
|
|
166
|
+
*/
|
|
167
|
+
defaultInverterState?: EnyoInverterStateEnum;
|
|
168
|
+
/**
|
|
169
|
+
* Static operating state to publish for the `battery` role. Ignored for other roles.
|
|
170
|
+
*/
|
|
171
|
+
defaultBatteryState?: EnyoBatteryStateEnum;
|
|
172
|
+
/**
|
|
173
|
+
* Optional identity written to appliance metadata. There is no SunSpec Common block to read it
|
|
174
|
+
* from, so the caller supplies serial/model/vendor if they want them populated.
|
|
175
|
+
*/
|
|
176
|
+
identity?: {
|
|
177
|
+
serialNumber?: string;
|
|
178
|
+
modelName?: string;
|
|
179
|
+
vendorName?: string;
|
|
180
|
+
};
|
|
181
|
+
}
|
|
101
182
|
/**
|
|
102
183
|
* Base interface for all SunSpec blocks
|
|
103
184
|
*/
|
|
@@ -581,6 +581,25 @@ class SunspecModbusClient {
|
|
|
581
581
|
this.poisonedUnits.add(unitId);
|
|
582
582
|
this.connectionHealth.recordFailure(error);
|
|
583
583
|
}
|
|
584
|
+
/**
|
|
585
|
+
* Publicly invalidate a unit's socket so {@link isHealthy} returns false and the next
|
|
586
|
+
* readData()/tryReconnect() cycle recycles it — the same effect as a timeout poison but
|
|
587
|
+
* for a caller-detected fault that isn't itself a Modbus timeout.
|
|
588
|
+
*
|
|
589
|
+
* The motivating case: a TCP reconnect succeeds but the follow-up model discovery comes
|
|
590
|
+
* back empty because the gateway (e.g. a SolarEdge unit) accepted the socket before it was
|
|
591
|
+
* ready to answer the SunSpec scan. The link looks alive, so without this the reconnect
|
|
592
|
+
* would be trusted, an empty model map cached, and every subsequent read would find no
|
|
593
|
+
* model while nothing ever triggers another reconnect. Poisoning here keeps the retry
|
|
594
|
+
* schedule firing until a real discovery lands. Idempotent; only logs on the first call.
|
|
595
|
+
*/
|
|
596
|
+
invalidateUnit(unitId, reason) {
|
|
597
|
+
if (!this.poisonedUnits.has(unitId)) {
|
|
598
|
+
console.warn(`SunspecModbusClient: invalidating unit ${unitId} socket — ${reason}; reconnect path will recycle it`);
|
|
599
|
+
}
|
|
600
|
+
this.poisonedUnits.add(unitId);
|
|
601
|
+
this.connectionHealth.recordFailure(new Error(reason));
|
|
602
|
+
}
|
|
584
603
|
/**
|
|
585
604
|
* A unit's socket is stale when the transport still reports it connected but no successful
|
|
586
605
|
* transaction has completed within staleSocketMs — the signature of a half-open link where
|
|
@@ -689,7 +708,16 @@ class SunspecModbusClient {
|
|
|
689
708
|
*/
|
|
690
709
|
async detectSunspecBaseAddress(unitId, customBaseAddress) {
|
|
691
710
|
const instance = this.getInstance(unitId);
|
|
692
|
-
// If custom base address provided, try it first (
|
|
711
|
+
// If a custom base address is provided, try it first (0-based, then 1-based variant).
|
|
712
|
+
//
|
|
713
|
+
// A custom base is only a real SunSpec anchor for a device whose map genuinely starts
|
|
714
|
+
// there. It is NOT an anchor when it points at a *model block* inside a shared unit —
|
|
715
|
+
// e.g. a SolarEdge meter block (~40188) co-resident with the inverter on unit 1: the
|
|
716
|
+
// "SunS" marker lives ONLY at the unit's SunSpec root (40000/40001), never at the meter
|
|
717
|
+
// block. So a miss here must NOT fail discovery; fall through to the standard root probe
|
|
718
|
+
// below. (This is exactly the reconnect path that used to strand the meter — its
|
|
719
|
+
// rediscovery threw "not SunSpec compliant" at 40188, returned no models, and poisoned
|
|
720
|
+
// the shared socket, dragging the inverter offline too.)
|
|
693
721
|
if (customBaseAddress !== undefined) {
|
|
694
722
|
console.log(`Detect models for custom base address '${customBaseAddress}' ...`);
|
|
695
723
|
// Try 0-based at custom address
|
|
@@ -722,41 +750,44 @@ class SunspecModbusClient {
|
|
|
722
750
|
catch (error) {
|
|
723
751
|
console.debug(`Could not read SunS at ${customBaseAddress + 1}:`, error);
|
|
724
752
|
}
|
|
753
|
+
console.debug(`No "SunS" marker at custom base ${customBaseAddress}/${customBaseAddress + 1} on unit ${unitId} — ` +
|
|
754
|
+
`falling back to the standard SunSpec root (40001/40000). Expected when the custom base points at a ` +
|
|
755
|
+
`model block inside a shared unit (e.g. a co-resident meter), whose anchor is the unit root.`);
|
|
725
756
|
}
|
|
726
|
-
|
|
727
|
-
|
|
728
|
-
|
|
729
|
-
|
|
730
|
-
|
|
731
|
-
|
|
732
|
-
|
|
733
|
-
|
|
734
|
-
|
|
735
|
-
|
|
736
|
-
|
|
737
|
-
}
|
|
738
|
-
}
|
|
739
|
-
catch (error) {
|
|
740
|
-
console.debug('Could not read SunS at 40001:', error);
|
|
741
|
-
}
|
|
742
|
-
// Try 0-based addressing
|
|
743
|
-
try {
|
|
744
|
-
const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40000, 2));
|
|
745
|
-
if (sunspecId.includes('SunS')) {
|
|
746
|
-
console.log('Detected 0-based addressing mode (base address: 40000)');
|
|
747
|
-
return {
|
|
748
|
-
baseAddress: 40000,
|
|
749
|
-
isZeroBased: true,
|
|
750
|
-
nextAddress: 40002
|
|
751
|
-
};
|
|
752
|
-
}
|
|
757
|
+
// Standard SunSpec root probe. Runs when no custom base was given, OR as the fallback
|
|
758
|
+
// when the custom base carried no marker. Try 1-based (40001) first (most common), then
|
|
759
|
+
// 0-based (40000).
|
|
760
|
+
try {
|
|
761
|
+
const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40001, 2));
|
|
762
|
+
if (sunspecId.includes('SunS')) {
|
|
763
|
+
console.log('Detected 1-based addressing mode (base address: 40001)');
|
|
764
|
+
return {
|
|
765
|
+
baseAddress: 40001,
|
|
766
|
+
isZeroBased: false,
|
|
767
|
+
nextAddress: 40003
|
|
768
|
+
};
|
|
753
769
|
}
|
|
754
|
-
|
|
755
|
-
|
|
770
|
+
}
|
|
771
|
+
catch (error) {
|
|
772
|
+
console.debug('Could not read SunS at 40001:', error);
|
|
773
|
+
}
|
|
774
|
+
// Try 0-based addressing
|
|
775
|
+
try {
|
|
776
|
+
const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40000, 2));
|
|
777
|
+
if (sunspecId.includes('SunS')) {
|
|
778
|
+
console.log('Detected 0-based addressing mode (base address: 40000)');
|
|
779
|
+
return {
|
|
780
|
+
baseAddress: 40000,
|
|
781
|
+
isZeroBased: true,
|
|
782
|
+
nextAddress: 40002
|
|
783
|
+
};
|
|
756
784
|
}
|
|
757
785
|
}
|
|
786
|
+
catch (error) {
|
|
787
|
+
console.debug('Could not read SunS at 40000:', error);
|
|
788
|
+
}
|
|
758
789
|
const addressesChecked = customBaseAddress !== undefined
|
|
759
|
-
? `${customBaseAddress}, ${customBaseAddress + 1}`
|
|
790
|
+
? `${customBaseAddress}, ${customBaseAddress + 1}, 40001, 40000`
|
|
760
791
|
: '40000 or 40001';
|
|
761
792
|
throw new Error(`Device is not SunSpec compliant - "SunS" identifier not found at addresses ${addressesChecked}`);
|
|
762
793
|
}
|
|
@@ -767,29 +798,35 @@ class SunspecModbusClient {
|
|
|
767
798
|
async discoverModels(unitId, customBaseAddress) {
|
|
768
799
|
const instance = this.getInstance(unitId);
|
|
769
800
|
const models = this.getModelsMap(unitId);
|
|
770
|
-
models.clear();
|
|
771
801
|
const modelList = this.getModelList(unitId);
|
|
772
|
-
modelList.length = 0;
|
|
773
802
|
const maxAddress = 50000; // Safety limit
|
|
774
|
-
let currentAddress = 0;
|
|
775
803
|
console.log(`Starting Sunspec model discovery for unit ${unitId}...`);
|
|
776
804
|
// Probe for the SunS identifier first. A missing identifier means the unit ID isn't a
|
|
777
805
|
// SunSpec device — common during unit-ID scans — and is logged at debug level so probes
|
|
778
806
|
// don't surface as errors. Mid-scan failures below remain at error level since they
|
|
779
807
|
// indicate a partial / malformed SunSpec map.
|
|
808
|
+
//
|
|
809
|
+
// IMPORTANT: we discover into TEMP buffers and only commit into the stored map once the
|
|
810
|
+
// walk yields at least one model. A reconnect probe can transiently fail (e.g. a single-
|
|
811
|
+
// session SolarEdge endpoint drops the socket with ECONNRESET on the first read after
|
|
812
|
+
// accepting the connection). Clearing the stored map up-front — as this used to — turned
|
|
813
|
+
// that blip into "no usable models", which trips tryReconnect()'s gate into invalidating
|
|
814
|
+
// a unit whose model map was perfectly good a moment ago. Preserving the last known-good
|
|
815
|
+
// map keeps a genuinely-connected sibling alive; a device that is really gone is still
|
|
816
|
+
// caught by read-health (isHealthy()).
|
|
780
817
|
let addressInfo;
|
|
781
818
|
try {
|
|
782
819
|
addressInfo = await this.detectSunspecBaseAddress(unitId, customBaseAddress);
|
|
783
820
|
}
|
|
784
821
|
catch (error) {
|
|
785
822
|
console.debug(`No SunSpec device at unit ${unitId}: ${error}`);
|
|
786
|
-
//
|
|
787
|
-
//
|
|
788
|
-
|
|
789
|
-
console.debug(`Discovery complete for unit ${unitId}. Found 0 models: []`);
|
|
823
|
+
// Same outcome as a normal "no device found"; keep at debug. Do NOT wipe the stored
|
|
824
|
+
// map — return it untouched so a transient probe failure can't erase good discovery.
|
|
825
|
+
console.debug(`Discovery incomplete for unit ${unitId}; keeping ${models.size} previously-discovered model(s).`);
|
|
790
826
|
return models;
|
|
791
827
|
}
|
|
792
|
-
|
|
828
|
+
const discovered = [];
|
|
829
|
+
let currentAddress = addressInfo.nextAddress;
|
|
793
830
|
try {
|
|
794
831
|
while (currentAddress < maxAddress) {
|
|
795
832
|
const buffer = await this.runExclusive(unitId, () => instance.readHoldingRegisters(currentAddress, 2));
|
|
@@ -805,19 +842,12 @@ class SunspecModbusClient {
|
|
|
805
842
|
console.debug(`Found end marker at address ${currentAddress}`);
|
|
806
843
|
break;
|
|
807
844
|
}
|
|
808
|
-
// Store discovered model
|
|
809
845
|
const model = {
|
|
810
846
|
id: modelId,
|
|
811
847
|
address: currentAddress,
|
|
812
848
|
length: modelLength
|
|
813
849
|
};
|
|
814
|
-
|
|
815
|
-
// findModel() resolves to the device's own block. Record every instance —
|
|
816
|
-
// including repeats like a meter's Common (id 1) — in the ordered list.
|
|
817
|
-
if (!models.has(modelId)) {
|
|
818
|
-
models.set(modelId, model);
|
|
819
|
-
}
|
|
820
|
-
modelList.push(model);
|
|
850
|
+
discovered.push(model);
|
|
821
851
|
// Per-model discovery step. The end-of-discovery summary below is the
|
|
822
852
|
// info-level outcome; the per-model walk is debug-only.
|
|
823
853
|
console.debug(`Discovered Model ${modelId} at address ${currentAddress} with length ${modelLength} (unit ${unitId})`);
|
|
@@ -828,6 +858,24 @@ class SunspecModbusClient {
|
|
|
828
858
|
catch (error) {
|
|
829
859
|
console.error(`Error during model discovery at address ${currentAddress} (unit ${unitId}): ${error}`);
|
|
830
860
|
}
|
|
861
|
+
if (discovered.length > 0) {
|
|
862
|
+
// Commit the fresh discovery atomically. Keep the FIRST (lowest-address) instance per
|
|
863
|
+
// id in the keyed directory so findModel() resolves to the device's own block; record
|
|
864
|
+
// every instance — including repeats like a meter's Common (id 1) — in the ordered list.
|
|
865
|
+
models.clear();
|
|
866
|
+
modelList.length = 0;
|
|
867
|
+
for (const model of discovered) {
|
|
868
|
+
if (!models.has(model.id)) {
|
|
869
|
+
models.set(model.id, model);
|
|
870
|
+
}
|
|
871
|
+
modelList.push(model);
|
|
872
|
+
}
|
|
873
|
+
}
|
|
874
|
+
else {
|
|
875
|
+
// The anchor answered but the walk yielded nothing (e.g. the socket dropped right
|
|
876
|
+
// after the SunS probe). Preserve the last known-good map rather than clobbering it.
|
|
877
|
+
console.debug(`Discovery for unit ${unitId} yielded no models; keeping ${models.size} previously-discovered model(s).`);
|
|
878
|
+
}
|
|
831
879
|
// Report every instance in address order so repeated ids (e.g. two Common blocks, or
|
|
832
880
|
// multiple meters) are visible — models.size would hide them behind the unique keys.
|
|
833
881
|
console.log(`Discovery complete for unit ${unitId}. Found ${modelList.length} model instance(s): [${modelList.map(m => m.id).join(', ')}]`);
|
|
@@ -969,12 +1017,87 @@ class SunspecModbusClient {
|
|
|
969
1017
|
return value;
|
|
970
1018
|
}
|
|
971
1019
|
/**
|
|
972
|
-
*
|
|
1020
|
+
* Read a contiguous span of `quantity` registers starting at `address` in a single logical
|
|
1021
|
+
* transaction — chunked at the 125-register Modbus limit and serialized on the unit's socket so no
|
|
1022
|
+
* other frame interleaves between chunks. FC03 holding registers by default; FC04 input registers
|
|
1023
|
+
* when `useInputRegisters` is true. The SunSpec model readers use {@link readModelBlock}; this is
|
|
1024
|
+
* the equivalent for callers reading a hand-defined block (see {@link SunspecCustomDevice}). Decode
|
|
1025
|
+
* individual fields out of the returned buffer with {@link decodeBlockValue}.
|
|
1026
|
+
*/
|
|
1027
|
+
async readRegisterBlock(unitId, address, quantity, useInputRegisters = false) {
|
|
1028
|
+
const reader = this.getReader(unitId);
|
|
1029
|
+
const MAX_REGISTERS_PER_READ = 125;
|
|
1030
|
+
try {
|
|
1031
|
+
const chunks = await this.runExclusive(unitId, async () => {
|
|
1032
|
+
const acc = [];
|
|
1033
|
+
for (let offset = 0; offset < quantity; offset += MAX_REGISTERS_PER_READ) {
|
|
1034
|
+
const count = Math.min(MAX_REGISTERS_PER_READ, quantity - offset);
|
|
1035
|
+
let result;
|
|
1036
|
+
if (useInputRegisters) {
|
|
1037
|
+
if (!reader.readInputRegisters) {
|
|
1038
|
+
throw new Error(`Reader for unit ${unitId} does not support FC04 input registers`);
|
|
1039
|
+
}
|
|
1040
|
+
result = await reader.readInputRegisters(address + offset, count);
|
|
1041
|
+
}
|
|
1042
|
+
else {
|
|
1043
|
+
result = await reader.readHoldingRegisters(address + offset, count);
|
|
1044
|
+
}
|
|
1045
|
+
if (!result.success || !result.value) {
|
|
1046
|
+
throw new Error(`Failed to read register block at address ${address + offset} (unit ${unitId}): ${result.error?.message || 'Unknown error'}`);
|
|
1047
|
+
}
|
|
1048
|
+
acc.push(result.value);
|
|
1049
|
+
}
|
|
1050
|
+
return acc;
|
|
1051
|
+
});
|
|
1052
|
+
this.connectionHealth.recordSuccess();
|
|
1053
|
+
return chunks.length === 1 ? chunks[0] : Buffer.concat(chunks);
|
|
1054
|
+
}
|
|
1055
|
+
catch (error) {
|
|
1056
|
+
this.connectionHealth.recordFailure(error);
|
|
1057
|
+
throw error;
|
|
1058
|
+
}
|
|
1059
|
+
}
|
|
1060
|
+
/**
|
|
1061
|
+
* Decode a typed value out of a buffer returned by {@link readRegisterBlock}, at a register offset
|
|
1062
|
+
* from the block start. A thin public wrapper over the same block-extraction the SunSpec model
|
|
1063
|
+
* readers use internally.
|
|
1064
|
+
*/
|
|
1065
|
+
decodeBlockValue(buffer, registerOffset, dataType, quantity = 1) {
|
|
1066
|
+
return this.extractValue(buffer, registerOffset, dataType, quantity);
|
|
1067
|
+
}
|
|
1068
|
+
/**
|
|
1069
|
+
* Helper to read holding register value(s) (FC03) using the fault-tolerant reader with data type
|
|
1070
|
+
* conversion.
|
|
973
1071
|
*/
|
|
974
1072
|
async readRegisterValue(unitId, address, quantity = 1, dataType) {
|
|
1073
|
+
return this.readTypedRegisters(unitId, address, quantity, dataType, false);
|
|
1074
|
+
}
|
|
1075
|
+
/**
|
|
1076
|
+
* Helper to read input register value(s) (FC04) using the fault-tolerant reader with data type
|
|
1077
|
+
* conversion. SunSpec itself never uses input registers, but plain-Modbus devices behind a
|
|
1078
|
+
* {@link SunspecCustomDevice} may expose live values there. Throws if the transport's reader does
|
|
1079
|
+
* not implement `readInputRegisters`.
|
|
1080
|
+
*/
|
|
1081
|
+
async readInputRegisterValue(unitId, address, quantity = 1, dataType) {
|
|
1082
|
+
return this.readTypedRegisters(unitId, address, quantity, dataType, true);
|
|
1083
|
+
}
|
|
1084
|
+
/**
|
|
1085
|
+
* Shared body of {@link readRegisterValue} / {@link readInputRegisterValue}. Runs the read under
|
|
1086
|
+
* the unit's transaction lock (so it inherits the timeout/poison/staleness resilience) and records
|
|
1087
|
+
* connection health on both success and failure.
|
|
1088
|
+
*/
|
|
1089
|
+
async readTypedRegisters(unitId, address, quantity, dataType, useInputRegisters) {
|
|
975
1090
|
const reader = this.getReader(unitId);
|
|
976
1091
|
try {
|
|
977
|
-
const result = await this.runExclusive(unitId, () =>
|
|
1092
|
+
const result = await this.runExclusive(unitId, () => {
|
|
1093
|
+
if (useInputRegisters) {
|
|
1094
|
+
if (!reader.readInputRegisters) {
|
|
1095
|
+
throw new Error(`Reader for unit ${unitId} does not support FC04 input registers`);
|
|
1096
|
+
}
|
|
1097
|
+
return reader.readInputRegisters(address, quantity);
|
|
1098
|
+
}
|
|
1099
|
+
return reader.readHoldingRegisters(address, quantity);
|
|
1100
|
+
});
|
|
978
1101
|
// Check if the read was successful
|
|
979
1102
|
if (!result.success || !result.value) {
|
|
980
1103
|
throw new Error(`Failed to read register at address ${address}: ${result.error?.message || 'Unknown error'}`);
|
|
@@ -216,6 +216,19 @@ export declare class SunspecModbusClient {
|
|
|
216
216
|
* 5-failure / 5-minute-staleness thresholds. Idempotent; only logs on the first poison.
|
|
217
217
|
*/
|
|
218
218
|
private poisonUnit;
|
|
219
|
+
/**
|
|
220
|
+
* Publicly invalidate a unit's socket so {@link isHealthy} returns false and the next
|
|
221
|
+
* readData()/tryReconnect() cycle recycles it — the same effect as a timeout poison but
|
|
222
|
+
* for a caller-detected fault that isn't itself a Modbus timeout.
|
|
223
|
+
*
|
|
224
|
+
* The motivating case: a TCP reconnect succeeds but the follow-up model discovery comes
|
|
225
|
+
* back empty because the gateway (e.g. a SolarEdge unit) accepted the socket before it was
|
|
226
|
+
* ready to answer the SunSpec scan. The link looks alive, so without this the reconnect
|
|
227
|
+
* would be trusted, an empty model map cached, and every subsequent read would find no
|
|
228
|
+
* model while nothing ever triggers another reconnect. Poisoning here keeps the retry
|
|
229
|
+
* schedule firing until a real discovery lands. Idempotent; only logs on the first call.
|
|
230
|
+
*/
|
|
231
|
+
invalidateUnit(unitId: number, reason: string): void;
|
|
219
232
|
/**
|
|
220
233
|
* A unit's socket is stale when the transport still reports it connected but no successful
|
|
221
234
|
* transaction has completed within staleSocketMs — the signature of a half-open link where
|
|
@@ -336,9 +349,38 @@ export declare class SunspecModbusClient {
|
|
|
336
349
|
*/
|
|
337
350
|
private extractValue;
|
|
338
351
|
/**
|
|
339
|
-
*
|
|
352
|
+
* Read a contiguous span of `quantity` registers starting at `address` in a single logical
|
|
353
|
+
* transaction — chunked at the 125-register Modbus limit and serialized on the unit's socket so no
|
|
354
|
+
* other frame interleaves between chunks. FC03 holding registers by default; FC04 input registers
|
|
355
|
+
* when `useInputRegisters` is true. The SunSpec model readers use {@link readModelBlock}; this is
|
|
356
|
+
* the equivalent for callers reading a hand-defined block (see {@link SunspecCustomDevice}). Decode
|
|
357
|
+
* individual fields out of the returned buffer with {@link decodeBlockValue}.
|
|
358
|
+
*/
|
|
359
|
+
readRegisterBlock(unitId: number, address: number, quantity: number, useInputRegisters?: boolean): Promise<Buffer>;
|
|
360
|
+
/**
|
|
361
|
+
* Decode a typed value out of a buffer returned by {@link readRegisterBlock}, at a register offset
|
|
362
|
+
* from the block start. A thin public wrapper over the same block-extraction the SunSpec model
|
|
363
|
+
* readers use internally.
|
|
364
|
+
*/
|
|
365
|
+
decodeBlockValue(buffer: Buffer, registerOffset: number, dataType: EnergyAppModbusDataType, quantity?: number): number | string | number[];
|
|
366
|
+
/**
|
|
367
|
+
* Helper to read holding register value(s) (FC03) using the fault-tolerant reader with data type
|
|
368
|
+
* conversion.
|
|
340
369
|
*/
|
|
341
370
|
readRegisterValue(unitId: number, address: number, quantity: number | undefined, dataType: EnergyAppModbusDataType): Promise<number | string | number[]>;
|
|
371
|
+
/**
|
|
372
|
+
* Helper to read input register value(s) (FC04) using the fault-tolerant reader with data type
|
|
373
|
+
* conversion. SunSpec itself never uses input registers, but plain-Modbus devices behind a
|
|
374
|
+
* {@link SunspecCustomDevice} may expose live values there. Throws if the transport's reader does
|
|
375
|
+
* not implement `readInputRegisters`.
|
|
376
|
+
*/
|
|
377
|
+
readInputRegisterValue(unitId: number, address: number, quantity: number | undefined, dataType: EnergyAppModbusDataType): Promise<number | string | number[]>;
|
|
378
|
+
/**
|
|
379
|
+
* Shared body of {@link readRegisterValue} / {@link readInputRegisterValue}. Runs the read under
|
|
380
|
+
* the unit's transaction lock (so it inherits the timeout/poison/staleness resilience) and records
|
|
381
|
+
* connection health on both success and failure.
|
|
382
|
+
*/
|
|
383
|
+
private readTypedRegisters;
|
|
342
384
|
/**
|
|
343
385
|
* Helper to write register value(s)
|
|
344
386
|
*/
|