@enyo-energy/sunspec-sdk 0.0.100 → 0.0.102

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
9
9
  /**
10
10
  * Current version of the enyo Energy App SDK.
11
11
  */
12
- exports.SDK_VERSION = '0.0.100';
12
+ exports.SDK_VERSION = '0.0.102';
13
13
  /**
14
14
  * Gets the current SDK version.
15
15
  * @returns The semantic version string of the SDK
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.100";
8
+ export declare const SDK_VERSION = "0.0.102";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
@@ -1,4 +1,4 @@
1
- import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.js";
1
+ import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.js";
2
2
  import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
3
3
  import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
4
4
  import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
@@ -68,12 +68,55 @@ export declare abstract class BaseSunspecDevice {
68
68
  * Ensure the Sunspec client is connected and models are discovered
69
69
  */
70
70
  protected ensureConnected(): Promise<void>;
71
+ /**
72
+ * Populate the per-unit model directory after the socket opens. Default: run SunSpec model
73
+ * discovery. Devices that read a hand-defined static register map instead of a discovered SunSpec
74
+ * directory (see {@link SunspecCustomDevice}) override this to a no-op.
75
+ */
76
+ protected discoverAfterConnect(): Promise<void>;
77
+ /**
78
+ * Validate that a just-completed reconnect actually restored a usable device. Default: re-run
79
+ * SunSpec discovery and check it against {@link getRequiredModelIds} (a socket that opens but comes
80
+ * back with no usable models means the gateway accepted the connection before it was ready to
81
+ * answer the scan). Returns false to treat the reconnect as failed so the backoff schedule keeps
82
+ * running. Discovery-less devices override this to just confirm the socket is open.
83
+ */
84
+ protected revalidateAfterReconnect(): Promise<boolean>;
71
85
  /**
72
86
  * Attempt a reconnection if the tiered retry schedule allows it.
73
87
  * Called from readData() when the device is disconnected.
74
88
  * Returns true if reconnection succeeded.
75
89
  */
76
90
  protected tryReconnect(): Promise<boolean>;
91
+ /**
92
+ * Model IDs this device needs to produce a reading; presence of ANY one means a
93
+ * discovery is usable (one-of semantics — devices expose mutually-exclusive
94
+ * encoding/phase variants, e.g. int+SF vs float, single- vs three-phase). Empty
95
+ * (the base default) means no specific requirement, so any model present
96
+ * suffices. Concrete devices override with their acceptable set — this is the
97
+ * single per-device source of truth reused by both the reconnect discovery gate
98
+ * ({@link isDiscoveryUsable}) and the connect-time presence gate
99
+ * ({@link hasRequiredModels}).
100
+ */
101
+ protected getRequiredModelIds(): readonly number[];
102
+ /**
103
+ * True if the current per-unit discovered-model map satisfies this device's
104
+ * requirement. The connect-time twin of {@link isDiscoveryUsable}: it inspects
105
+ * the already-populated map via findModel() rather than a freshly-returned one.
106
+ * Only meaningful for devices that declare a non-empty required set.
107
+ */
108
+ protected hasRequiredModels(): boolean;
109
+ /**
110
+ * Decide whether a post-reconnect model discovery is usable. A reconnect that
111
+ * establishes the TCP socket but comes back empty (or with only a Common block)
112
+ * means the device accepted the connection before it was ready to answer the
113
+ * SunSpec scan; the discovered-model map is now missing this device's data
114
+ * model, so trusting the reconnect would leave every read finding no model.
115
+ * Validated generically against {@link getRequiredModelIds}: with a declared
116
+ * set, at least one of those ids must be present; with none declared, fall back
117
+ * to "any model present".
118
+ */
119
+ protected isDiscoveryUsable(models: Map<number, SunspecModel>): boolean;
77
120
  /**
78
121
  * Hook for subclasses to react to a failed reconnect attempt. Called once
79
122
  * per failed attempt with the running consecutive-failure count.
@@ -142,6 +185,13 @@ export declare class SunspecInverter extends BaseSunspecDevice {
142
185
  private readonly pvPowerSource;
143
186
  /** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
144
187
  private static readonly CONNECTION_FAULT_THRESHOLD;
188
+ /**
189
+ * The inverter data models this device can read (int+SF 101/103 and IEEE-754
190
+ * float 111/112/113). A post-reconnect discovery that finds none of these has
191
+ * not really recovered the inverter, so {@link isDiscoveryUsable} rejects it —
192
+ * see the override below.
193
+ */
194
+ private static readonly INVERTER_MODEL_IDS;
145
195
  /**
146
196
  * Require this many consecutive operatingState=7 (FAULT) reads before
147
197
  * reporting Faulted. Debounces transient single-poll FAULT reads (e.g. a
@@ -218,6 +268,14 @@ export declare class SunspecInverter extends BaseSunspecDevice {
218
268
  private hasErrorSetChanged;
219
269
  private buildStatusMessage;
220
270
  private detectAndEmitStatusTransition;
271
+ /**
272
+ * A reconnect has only recovered the inverter if discovery finds one of its
273
+ * data models. An SE gateway can accept the new socket and answer a partial
274
+ * scan (e.g. only the Common block) before the inverter map is ready — the
275
+ * base size>0 rule would accept that, but every inverter read would then find
276
+ * no 101/103/111/112/113 model and report 0 W. Require an actual inverter model.
277
+ */
278
+ protected getRequiredModelIds(): readonly number[];
221
279
  protected onConnectionFailure(consecutiveFailures: number): Promise<void>;
222
280
  protected onConnectionRestored(): Promise<void>;
223
281
  /**
@@ -430,6 +488,13 @@ export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryF
430
488
  export declare class SunspecBattery extends BaseSunspecDevice {
431
489
  private readonly featureMode;
432
490
  private readonly capabilities;
491
+ /**
492
+ * Battery data models this device can read: Battery (124, full decode) and
493
+ * BatteryBase (802, derived decode). BatteryControl (803) is intentionally
494
+ * excluded — it is a decode stub that yields no telemetry — so a rediscovery
495
+ * that returns only 803 is treated as unrecovered, matching the connect() gate.
496
+ */
497
+ private static readonly BATTERY_MODEL_IDS;
433
498
  private snapshotService?;
434
499
  private calibrationDriver?;
435
500
  private batteryCalibrator?;
@@ -478,6 +543,7 @@ export declare class SunspecBattery extends BaseSunspecDevice {
478
543
  * `CalibrationTrigger`.
479
544
  */
480
545
  getBatteryCalibrator(): BatteryCalibrator<SunspecBatteryControls> | undefined;
546
+ protected getRequiredModelIds(): readonly number[];
481
547
  /**
482
548
  * Connect to the battery and create/update the appliance
483
549
  */
@@ -646,6 +712,12 @@ export declare class SunspecBattery extends BaseSunspecDevice {
646
712
  */
647
713
  export declare class SunspecMeter extends BaseSunspecDevice {
648
714
  private readonly capabilities;
715
+ /**
716
+ * Meter data models this device can read, across int+SF (201/203/204) and
717
+ * IEEE-754 float (211/212/213/214) encodings and single/split/three-phase
718
+ * variants. Used when the meter is not bound to a specific instance.
719
+ */
720
+ private static readonly METER_MODEL_IDS;
649
721
  constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecMeterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
650
722
  /**
651
723
  * The specific meter model instance this meter reads, when its unit hosts more than one
@@ -659,6 +731,11 @@ export declare class SunspecMeter extends BaseSunspecDevice {
659
731
  * {@link SunspecModbusClient.findModels}). Call before {@link connect}.
660
732
  */
661
733
  bindMeterModel(model: SunspecModel): void;
734
+ /**
735
+ * A bound meter requires ITS own pinned model id to reappear after a
736
+ * rediscovery; an unbound meter accepts any meter model on its unit.
737
+ */
738
+ protected getRequiredModelIds(): readonly number[];
662
739
  /**
663
740
  * Connect to the meter and create/update the appliance
664
741
  */
@@ -672,4 +749,70 @@ export declare class SunspecMeter extends BaseSunspecDevice {
672
749
  */
673
750
  readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
674
751
  }
752
+ /**
753
+ * A generic, pre-configured Modbus device that plugs into the exact same resilient lifecycle as the
754
+ * SunSpec devices — the per-device {@link ConnectionRetryManager}, {@link tryReconnect} tiered backoff,
755
+ * {@link markOffline}/{@link reassertConnectedIfRecovered} shared-socket healing, and the client's
756
+ * per-transaction timeout/poison/staleness guards — but reads a **hand-defined static register map**
757
+ * instead of a discovered SunSpec model directory.
758
+ *
759
+ * It emulates a configurable {@link SunspecCustomDeviceConfig.role} (`meter` | `inverter` | `battery`):
760
+ * the role selects the appliance type created on connect and which EnyoDataBus values message
761
+ * {@link readData} publishes, and each {@link SunspecCustomRegister} maps onto one numeric field of
762
+ * that message. Supports FC03 holding registers (default), FC04 input registers, and writes.
763
+ *
764
+ * Discovery is fully bypassed: {@link connect} opens the socket only, and the reconnect path is
765
+ * validated by socket liveness rather than a SunSpec scan.
766
+ */
767
+ export declare class SunspecCustomDevice extends BaseSunspecDevice {
768
+ private readonly config;
769
+ /** Read plan derived once from the static register map (see {@link planBlocks}). */
770
+ private plannedBlocks?;
771
+ constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, config: SunspecCustomDeviceConfig, unitId?: number, port?: number, baseAddress?: number, retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
772
+ /**
773
+ * No SunSpec model directory to build — this device reads pre-defined static addresses. Overriding
774
+ * the base discovery hook to a no-op is what lets {@link ensureConnected}/{@link connect} open the
775
+ * socket without a SunS scan.
776
+ */
777
+ protected discoverAfterConnect(): Promise<void>;
778
+ /**
779
+ * A reconnect is usable as soon as the socket is open again — there is no model map to revalidate.
780
+ * Without this override the base default would run SunSpec discovery, find nothing, and treat every
781
+ * reconnect as a permanent failure.
782
+ */
783
+ protected revalidateAfterReconnect(): Promise<boolean>;
784
+ /**
785
+ * Connect the underlying socket (no discovery) and create/update the appliance for the configured
786
+ * role. Identity metadata comes from {@link SunspecCustomDeviceConfig.identity} since there is no
787
+ * SunSpec Common block to read it from.
788
+ */
789
+ connect(): Promise<void>;
790
+ disconnect(): Promise<void>;
791
+ readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
792
+ /**
793
+ * Write a value to a pre-configured writable register. Delegates to the client's resilient
794
+ * {@link SunspecModbusClient.writeRegisterValue}.
795
+ */
796
+ writeCustomRegister(name: string, value: number | number[]): Promise<boolean>;
797
+ /**
798
+ * Read every configured register as a small number of block reads and extract each register from
799
+ * its block buffer by offset (mirroring the SunSpec model-block read). Applies the fixed decimal
800
+ * scaling and returns a field → value map. Non-numeric reads (e.g. a `string` dataType that can't
801
+ * populate a numeric databus field) are skipped with a warning.
802
+ */
803
+ private readConfiguredRegisters;
804
+ /** Lazily compute and cache the block read plan; the register map is static per device. */
805
+ private getPlannedBlocks;
806
+ /**
807
+ * Group the configured registers (separately per function code) sorted by address, coalescing them
808
+ * — across gaps — into blocks no wider than {@link SunspecCustomDeviceConfig.blockSize}. A new block
809
+ * starts whenever adding the next register would exceed that span. Each block records its members'
810
+ * offsets so a single read can be sliced into all of them.
811
+ */
812
+ private planBlocks;
813
+ private buildRoleMessage;
814
+ private buildMeterMessage;
815
+ private buildInverterMessage;
816
+ private buildBatteryMessage;
817
+ }
675
818
  export {};