openstudio-standards 0.8.5 → 0.8.7

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (174) hide show
  1. checksums.yaml +4 -4
  2. data/data/standards/test_performance_expected_dd_results.csv +90 -90
  3. data/lib/openstudio-standards/btap/activity.rb +858 -61
  4. data/lib/openstudio-standards/btap/attributes.rb +297 -103
  5. data/lib/openstudio-standards/btap/bridging.rb +1335 -593
  6. data/lib/openstudio-standards/btap/btap.rb +60 -181
  7. data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +199 -142
  8. data/lib/openstudio-standards/btap/common/constructions.json +1275 -0
  9. data/lib/openstudio-standards/btap/common/costs.csv +1969 -0
  10. data/lib/openstudio-standards/btap/common/costs_local_factors.csv +2315 -0
  11. data/lib/openstudio-standards/btap/common/materials_glazing.csv +61 -0
  12. data/lib/openstudio-standards/btap/{common_resources → common}/materials_hvac.csv +1685 -1685
  13. data/lib/openstudio-standards/btap/{common_resources → common}/materials_lighting.csv +266 -266
  14. data/lib/openstudio-standards/btap/common/materials_opaque.csv +214 -0
  15. data/lib/openstudio-standards/btap/common/necb_building_types.csv +35 -0
  16. data/lib/openstudio-standards/btap/common/necb_space_types.csv +110 -0
  17. data/lib/openstudio-standards/btap/common/thermal_bridging.csv +73 -0
  18. data/lib/openstudio-standards/btap/costing/btap_costing.rb +346 -429
  19. data/lib/openstudio-standards/btap/costing/database.rb +104 -0
  20. data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +356 -344
  21. data/lib/openstudio-standards/btap/costing/dcv_costing.rb +282 -296
  22. data/lib/openstudio-standards/btap/costing/envelope_costing.rb +179 -192
  23. data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2477 -2316
  24. data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +127 -142
  25. data/lib/openstudio-standards/btap/costing/lighting_costing.rb +216 -198
  26. data/lib/openstudio-standards/btap/costing/nv_costing.rb +522 -523
  27. data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +649 -649
  28. data/lib/openstudio-standards/btap/costing/shw_costing.rb +626 -625
  29. data/lib/openstudio-standards/btap/costing/thermal_bridging_costing.rb +72 -0
  30. data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2363 -2361
  31. data/lib/openstudio-standards/btap/deprecated.rb +1033 -0
  32. data/lib/openstudio-standards/btap/envelope.rb +313 -572
  33. data/lib/openstudio-standards/btap/fileio.rb +152 -1070
  34. data/lib/openstudio-standards/btap/geometry.rb +486 -766
  35. data/lib/openstudio-standards/btap/linear_regression.rb +130 -0
  36. data/lib/openstudio-standards/btap/paths.rb +46 -0
  37. data/lib/openstudio-standards/btap/qaqc/analysis.rb +163 -0
  38. data/lib/openstudio-standards/btap/qaqc/data.rb +2293 -0
  39. data/lib/openstudio-standards/btap/qaqc/datapoint.rb +641 -0
  40. data/lib/openstudio-standards/btap/schedules.rb +11 -611
  41. data/lib/openstudio-standards/btap/structure.rb +574 -189
  42. data/lib/openstudio-standards/constructions/materials/information.rb +1 -1
  43. data/lib/openstudio-standards/create_typical/create_typical.rb +1 -1
  44. data/lib/openstudio-standards/exterior_lighting/create.rb +135 -85
  45. data/lib/openstudio-standards/exterior_lighting/data/typical_exterior_lighting.json +20 -0
  46. data/lib/openstudio-standards/exterior_lighting/information.rb +23 -2
  47. data/lib/openstudio-standards/geometry/create.rb +7 -3
  48. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +3 -2
  49. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +3 -2
  50. data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +84 -84
  51. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +4 -4
  52. data/lib/openstudio-standards/refrigeration/create_walkin.rb +45 -5
  53. data/lib/openstudio-standards/refrigeration/data/refrigerated_walkins.csv +75 -75
  54. data/lib/openstudio-standards/schedules/parametric.rb +6 -0
  55. data/lib/openstudio-standards/service_water_heating/create_typical.rb +10 -3
  56. data/lib/openstudio-standards/service_water_heating/create_water_heating_loop.rb +30 -14
  57. data/lib/openstudio-standards/service_water_heating/information.rb +4 -1
  58. data/lib/openstudio-standards/sql_file/unmet_hours.rb +2 -1
  59. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +3 -1
  60. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +3 -1
  61. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +12 -0
  62. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +18432 -3072
  63. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +26 -0
  64. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +8532 -1422
  65. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +26 -0
  66. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +8532 -1422
  67. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +16 -0
  68. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.computer_room_acs.json +30 -30
  69. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +7560 -1260
  70. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +1 -2
  71. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.boilers.json +16 -0
  72. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_properties.json +7560 -1260
  73. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +3 -3
  74. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +1 -2
  75. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +22 -0
  76. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_properties.json +7236 -1206
  77. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.furnaces.json +223 -19
  78. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +37 -1
  79. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.boilers.json +3 -0
  80. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.construction_properties.json +6900 -1150
  81. data/lib/openstudio-standards/standards/cbes/data/cbes.schedules.json +1 -1
  82. data/lib/openstudio-standards/standards/deer/data/deer.schedules.json +1 -1
  83. data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/surface_thermal_transmittance.json +76 -40
  84. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/surface_thermal_transmittance.json +76 -40
  85. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +6 -4
  86. data/lib/openstudio-standards/standards/necb/NECB2011/NECB2011_QAQC.json +2988 -0
  87. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +25 -3
  88. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +672 -534
  89. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Hospital.osm +1791 -1792
  90. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LEEPMultiTower.osm +7 -1
  91. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LEEPTownHouse.osm +7 -1
  92. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LargeHotel.osm +5 -6
  93. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LargeOffice.osm +8 -9
  94. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm +10 -4
  95. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm +14 -15
  96. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Outpatient.osm +7 -1
  97. data/lib/openstudio-standards/standards/necb/NECB2011/data/surface_thermal_transmittance.json +76 -40
  98. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +14 -6
  99. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +542 -130
  100. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +30 -63
  101. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +7 -2
  102. data/lib/openstudio-standards/standards/necb/NECB2015/data/surface_thermal_transmittance.json +90 -0
  103. data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +8 -6
  104. data/lib/openstudio-standards/standards/necb/NECB2017/data/surface_thermal_transmittance.json +76 -40
  105. data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +2 -1
  106. data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +0 -117
  107. data/lib/openstudio-standards/standards/necb/NECB2020/data/surface_thermal_transmittance.json +76 -45
  108. data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +218 -0
  109. data/lib/openstudio-standards/standards/necb/common/construction_defaults.osm +12 -7
  110. data/lib/openstudio-standards/standards/standard.rb +1 -1
  111. data/lib/openstudio-standards/version.rb +1 -1
  112. data/lib/openstudio-standards.rb +9 -4
  113. metadata +59 -66
  114. data/data/inventory/thermal_bridging.csv +0 -90
  115. data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
  116. data/data/standards/openstudio_standards_duplicates_log.csv +0 -7962
  117. data/lib/openstudio-standards/btap/NECB_building_types.csv +0 -35
  118. data/lib/openstudio-standards/btap/NECB_space_types.csv +0 -109
  119. data/lib/openstudio-standards/btap/WeatherData1.json +0 -2110
  120. data/lib/openstudio-standards/btap/WeatherData1.xlsx +0 -0
  121. data/lib/openstudio-standards/btap/btap_result.rb +0 -1144
  122. data/lib/openstudio-standards/btap/btap_test_helper.rb +0 -86
  123. data/lib/openstudio-standards/btap/common_paths.rb +0 -81
  124. data/lib/openstudio-standards/btap/common_resources/ConstructionProperties.csv +0 -52
  125. data/lib/openstudio-standards/btap/common_resources/Constructions.csv +0 -37
  126. data/lib/openstudio-standards/btap/common_resources/construction_sets.csv +0 -1270
  127. data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +0 -121
  128. data/lib/openstudio-standards/btap/common_resources/constructions_opaque.csv +0 -2256
  129. data/lib/openstudio-standards/btap/common_resources/costs.csv +0 -1897
  130. data/lib/openstudio-standards/btap/common_resources/costs_local_factors.csv +0 -2315
  131. data/lib/openstudio-standards/btap/common_resources/materials_glazing.csv +0 -35
  132. data/lib/openstudio-standards/btap/common_resources/materials_opaque.csv +0 -164
  133. data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +0 -359
  134. data/lib/openstudio-standards/btap/costing/btap_workflow.rb +0 -117
  135. data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +0 -11
  136. data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +0 -136
  137. data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +0 -173
  138. data/lib/openstudio-standards/btap/costing/dummy.epw +0 -8768
  139. data/lib/openstudio-standards/btap/costing/dummy.osm +0 -5320
  140. data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +0 -42
  141. data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +0 -225
  142. data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +0 -28705
  143. data/lib/openstudio-standards/btap/costing/parallel_tests.rb +0 -92
  144. data/lib/openstudio-standards/btap/costing/test_list.txt +0 -15
  145. data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +0 -27
  146. data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +0 -80
  147. data/lib/openstudio-standards/btap/necb_2011_spacetype_info.csv +0 -225
  148. data/lib/openstudio-standards/btap/utilities/Add_template_field_to_json.rb +0 -22
  149. data/lib/openstudio-standards/btap/utilities/convert_surfaces_to_adiabatic_necb_8426.rb +0 -204
  150. data/lib/openstudio-standards/btap/utilities/generate_space_types.rb +0 -8
  151. data/lib/openstudio-standards/btap/utilities/necb_to_epw_map.rb +0 -50
  152. data/lib/openstudio-standards/btap/utilities/os_sim_extract.rb +0 -48
  153. data/lib/openstudio-standards/btap/utilities/rename_surfaces.rb +0 -24
  154. data/lib/openstudio-standards/btap/utilities/round_surf_coords.rb +0 -32
  155. data/lib/openstudio-standards/btap/utilities/sched_create.rb +0 -145
  156. data/lib/openstudio-standards/btap/utilities/set_mult_to_adiabatic.rb +0 -53
  157. data/lib/openstudio-standards/btap/utilities/space_type.rb +0 -78
  158. data/lib/openstudio-standards/btap/utilities/weatherData1_xlsx_to_json.rb +0 -56
  159. data/lib/openstudio-standards/btap/vintagizer.rb +0 -161
  160. data/lib/openstudio-standards/btap/visualization.rb +0 -72
  161. data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2011_spacetype_info.csv +0 -225
  162. data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +0 -79
  163. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +0 -2656
  164. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +0 -653
  165. data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +0 -28705
  166. data/lib/openstudio-standards/standards/necb/common/utility_pricing_2025-02-20.csv +0 -92
  167. /data/lib/openstudio-standards/btap/{common_resources → common}/carbon_frame.csv +0 -0
  168. /data/lib/openstudio-standards/btap/{common_resources → common}/carbon_glazing.csv +0 -0
  169. /data/lib/openstudio-standards/btap/{common_resources → common}/carbon_opaque.csv +0 -0
  170. /data/lib/openstudio-standards/btap/{common_resources → common}/hvac_vent_ahu.csv +0 -0
  171. /data/lib/openstudio-standards/btap/{common_resources → common}/lighting.csv +0 -0
  172. /data/lib/openstudio-standards/btap/{common_resources → common}/lighting_sets.csv +0 -0
  173. /data/lib/openstudio-standards/btap/{common_resources → common}/locations.csv +0 -0
  174. /data/lib/openstudio-standards/btap/{costing → common}/mech_sizing.json +0 -0
metadata CHANGED
@@ -1,7 +1,7 @@
1
1
  --- !ruby/object:Gem::Specification
2
2
  name: openstudio-standards
3
3
  version: !ruby/object:Gem::Version
4
- version: 0.8.5
4
+ version: 0.8.7
5
5
  platform: ruby
6
6
  authors:
7
7
  - Mark Adams
@@ -39,7 +39,7 @@ authors:
39
39
  autorequire:
40
40
  bindir: bin
41
41
  cert_chain: []
42
- date: 2026-01-05 00:00:00.000000000 Z
42
+ date: 2026-10-21 00:00:00.000000000 Z
43
43
  dependencies:
44
44
  - !ruby/object:Gem::Dependency
45
45
  name: bundler
@@ -265,6 +265,20 @@ dependencies:
265
265
  - - '='
266
266
  - !ruby/object:Gem::Version
267
267
  version: 0.22.0
268
+ - !ruby/object:Gem::Dependency
269
+ name: solargraph
270
+ requirement: !ruby/object:Gem::Requirement
271
+ requirements:
272
+ - - "~>"
273
+ - !ruby/object:Gem::Version
274
+ version: 0.58.0
275
+ type: :development
276
+ prerelease: false
277
+ version_requirements: !ruby/object:Gem::Requirement
278
+ requirements:
279
+ - - "~>"
280
+ - !ruby/object:Gem::Version
281
+ version: 0.58.0
268
282
  - !ruby/object:Gem::Dependency
269
283
  name: yard
270
284
  requirement: !ruby/object:Gem::Requirement
@@ -293,6 +307,20 @@ dependencies:
293
307
  - - "~>"
294
308
  - !ruby/object:Gem::Version
295
309
  version: '3'
310
+ - !ruby/object:Gem::Dependency
311
+ name: aws-sdk-s3
312
+ requirement: !ruby/object:Gem::Requirement
313
+ requirements:
314
+ - - ">="
315
+ - !ruby/object:Gem::Version
316
+ version: '0'
317
+ type: :development
318
+ prerelease: false
319
+ version_requirements: !ruby/object:Gem::Requirement
320
+ requirements:
321
+ - - ">="
322
+ - !ruby/object:Gem::Version
323
+ version: '0'
296
324
  description: The openstudio-standards library provides methods for programatically
297
325
  generating, modifying, and checking OpenStudio building energy models. It can create
298
326
  a typical building from user geometry, template geometry, or programmatically generated
@@ -611,12 +639,9 @@ files:
611
639
  - data/geometry/DOERefSmallOffice.json
612
640
  - data/geometry/DOERefWarehouse.json
613
641
  - data/geometry/DOERefWarehouse.osm
614
- - data/inventory/thermal_bridging.csv
615
- - data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx
616
642
  - data/standards/exclude_list.csv
617
643
  - data/standards/export_OpenStudio_libraries.rb
618
644
  - data/standards/manage_OpenStudio_Standards.rb
619
- - data/standards/openstudio_standards_duplicates_log.csv
620
645
  - data/standards/templates_to_climate_zones.json
621
646
  - data/standards/test_performance_expected_dd_results.csv
622
647
  - data/weather/ARCATA_725945_CZ2010.ddy
@@ -838,82 +863,54 @@ files:
838
863
  - data/weather/VNM_SVN_Ho.Chi.Minh-Tan.Son.Nhat.Intl.AP.489000_TMYx.epw
839
864
  - data/weather/VNM_SVN_Ho.Chi.Minh-Tan.Son.Nhat.Intl.AP.489000_TMYx.stat
840
865
  - lib/openstudio-standards.rb
841
- - lib/openstudio-standards/btap/NECB_building_types.csv
842
- - lib/openstudio-standards/btap/NECB_space_types.csv
843
- - lib/openstudio-standards/btap/WeatherData1.json
844
- - lib/openstudio-standards/btap/WeatherData1.xlsx
845
866
  - lib/openstudio-standards/btap/activity.rb
846
867
  - lib/openstudio-standards/btap/attributes.rb
847
868
  - lib/openstudio-standards/btap/bridging.rb
848
869
  - lib/openstudio-standards/btap/btap.rb
849
- - lib/openstudio-standards/btap/btap_result.rb
850
- - lib/openstudio-standards/btap/btap_test_helper.rb
851
870
  - lib/openstudio-standards/btap/carbon/btap_carbon.rb
852
- - lib/openstudio-standards/btap/common_paths.rb
853
- - lib/openstudio-standards/btap/common_resources/ConstructionProperties.csv
854
- - lib/openstudio-standards/btap/common_resources/Constructions.csv
855
- - lib/openstudio-standards/btap/common_resources/carbon_frame.csv
856
- - lib/openstudio-standards/btap/common_resources/carbon_glazing.csv
857
- - lib/openstudio-standards/btap/common_resources/carbon_opaque.csv
858
- - lib/openstudio-standards/btap/common_resources/construction_sets.csv
859
- - lib/openstudio-standards/btap/common_resources/constructions_glazing.csv
860
- - lib/openstudio-standards/btap/common_resources/constructions_opaque.csv
861
- - lib/openstudio-standards/btap/common_resources/costs.csv
862
- - lib/openstudio-standards/btap/common_resources/costs_local_factors.csv
863
- - lib/openstudio-standards/btap/common_resources/hvac_vent_ahu.csv
864
- - lib/openstudio-standards/btap/common_resources/lighting.csv
865
- - lib/openstudio-standards/btap/common_resources/lighting_sets.csv
866
- - lib/openstudio-standards/btap/common_resources/locations.csv
867
- - lib/openstudio-standards/btap/common_resources/materials_glazing.csv
868
- - lib/openstudio-standards/btap/common_resources/materials_hvac.csv
869
- - lib/openstudio-standards/btap/common_resources/materials_lighting.csv
870
- - lib/openstudio-standards/btap/common_resources/materials_opaque.csv
871
+ - lib/openstudio-standards/btap/common/carbon_frame.csv
872
+ - lib/openstudio-standards/btap/common/carbon_glazing.csv
873
+ - lib/openstudio-standards/btap/common/carbon_opaque.csv
874
+ - lib/openstudio-standards/btap/common/constructions.json
875
+ - lib/openstudio-standards/btap/common/costs.csv
876
+ - lib/openstudio-standards/btap/common/costs_local_factors.csv
877
+ - lib/openstudio-standards/btap/common/hvac_vent_ahu.csv
878
+ - lib/openstudio-standards/btap/common/lighting.csv
879
+ - lib/openstudio-standards/btap/common/lighting_sets.csv
880
+ - lib/openstudio-standards/btap/common/locations.csv
881
+ - lib/openstudio-standards/btap/common/materials_glazing.csv
882
+ - lib/openstudio-standards/btap/common/materials_hvac.csv
883
+ - lib/openstudio-standards/btap/common/materials_lighting.csv
884
+ - lib/openstudio-standards/btap/common/materials_opaque.csv
885
+ - lib/openstudio-standards/btap/common/mech_sizing.json
886
+ - lib/openstudio-standards/btap/common/necb_building_types.csv
887
+ - lib/openstudio-standards/btap/common/necb_space_types.csv
888
+ - lib/openstudio-standards/btap/common/thermal_bridging.csv
871
889
  - lib/openstudio-standards/btap/costing/README.md
872
890
  - lib/openstudio-standards/btap/costing/btap_costing.rb
873
- - lib/openstudio-standards/btap/costing/btap_measure_helper.rb
874
- - lib/openstudio-standards/btap/costing/btap_workflow.rb
875
- - lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb
876
- - lib/openstudio-standards/btap/costing/cost_building_from_file.rb
877
- - lib/openstudio-standards/btap/costing/costing_database_wrapper.rb
891
+ - lib/openstudio-standards/btap/costing/database.rb
878
892
  - lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb
879
893
  - lib/openstudio-standards/btap/costing/dcv_costing.rb
880
- - lib/openstudio-standards/btap/costing/dummy.epw
881
- - lib/openstudio-standards/btap/costing/dummy.osm
882
894
  - lib/openstudio-standards/btap/costing/envelope_costing.rb
883
895
  - lib/openstudio-standards/btap/costing/heating_cooling_costing.rb
884
896
  - lib/openstudio-standards/btap/costing/led_lighting_costing.rb
885
897
  - lib/openstudio-standards/btap/costing/lighting_costing.rb
886
- - lib/openstudio-standards/btap/costing/mech_sizing.json
887
- - lib/openstudio-standards/btap/costing/neb_end_use_prices.csv
888
- - lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv
889
- - lib/openstudio-standards/btap/costing/necb_reference_runs.csv
890
898
  - lib/openstudio-standards/btap/costing/nv_costing.rb
891
- - lib/openstudio-standards/btap/costing/parallel_tests.rb
892
899
  - lib/openstudio-standards/btap/costing/pv_ground_costing.rb
893
900
  - lib/openstudio-standards/btap/costing/shw_costing.rb
894
- - lib/openstudio-standards/btap/costing/test_list.txt
895
- - lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb
896
- - lib/openstudio-standards/btap/costing/test_run_costing_tests.rb
901
+ - lib/openstudio-standards/btap/costing/thermal_bridging_costing.rb
897
902
  - lib/openstudio-standards/btap/costing/ventilation_costing.rb
903
+ - lib/openstudio-standards/btap/deprecated.rb
898
904
  - lib/openstudio-standards/btap/envelope.rb
899
905
  - lib/openstudio-standards/btap/fileio.rb
900
906
  - lib/openstudio-standards/btap/geometry.rb
901
- - lib/openstudio-standards/btap/necb_2011_spacetype_info.csv
907
+ - lib/openstudio-standards/btap/linear_regression.rb
908
+ - lib/openstudio-standards/btap/paths.rb
909
+ - lib/openstudio-standards/btap/qaqc/analysis.rb
910
+ - lib/openstudio-standards/btap/qaqc/data.rb
911
+ - lib/openstudio-standards/btap/qaqc/datapoint.rb
902
912
  - lib/openstudio-standards/btap/schedules.rb
903
913
  - lib/openstudio-standards/btap/structure.rb
904
- - lib/openstudio-standards/btap/utilities/Add_template_field_to_json.rb
905
- - lib/openstudio-standards/btap/utilities/convert_surfaces_to_adiabatic_necb_8426.rb
906
- - lib/openstudio-standards/btap/utilities/generate_space_types.rb
907
- - lib/openstudio-standards/btap/utilities/necb_to_epw_map.rb
908
- - lib/openstudio-standards/btap/utilities/os_sim_extract.rb
909
- - lib/openstudio-standards/btap/utilities/rename_surfaces.rb
910
- - lib/openstudio-standards/btap/utilities/round_surf_coords.rb
911
- - lib/openstudio-standards/btap/utilities/sched_create.rb
912
- - lib/openstudio-standards/btap/utilities/set_mult_to_adiabatic.rb
913
- - lib/openstudio-standards/btap/utilities/space_type.rb
914
- - lib/openstudio-standards/btap/utilities/weatherData1_xlsx_to_json.rb
915
- - lib/openstudio-standards/btap/vintagizer.rb
916
- - lib/openstudio-standards/btap/visualization.rb
917
914
  - lib/openstudio-standards/constructions/create.rb
918
915
  - lib/openstudio-standards/constructions/information.rb
919
916
  - lib/openstudio-standards/constructions/materials/information.rb
@@ -2354,6 +2351,7 @@ files:
2354
2351
  - lib/openstudio-standards/standards/necb/ECMS/loads.rb
2355
2352
  - lib/openstudio-standards/standards/necb/ECMS/nv.rb
2356
2353
  - lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb
2354
+ - lib/openstudio-standards/standards/necb/NECB2011/NECB2011_QAQC.json
2357
2355
  - lib/openstudio-standards/standards/necb/NECB2011/autozone.rb
2358
2356
  - lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb
2359
2357
  - lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb
@@ -2398,7 +2396,6 @@ files:
2398
2396
  - lib/openstudio-standards/standards/necb/NECB2011/data/led_lighting_data.json
2399
2397
  - lib/openstudio-standards/standards/necb/NECB2011/data/materials.json
2400
2398
  - lib/openstudio-standards/standards/necb/NECB2011/data/motors.json
2401
- - lib/openstudio-standards/standards/necb/NECB2011/data/necb_2011_spacetype_info.csv
2402
2399
  - lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json
2403
2400
  - lib/openstudio-standards/standards/necb/NECB2011/data/necb_hvac_system_selection_type.json
2404
2401
  - lib/openstudio-standards/standards/necb/NECB2011/data/prototype_inputs.json
@@ -2454,6 +2451,7 @@ files:
2454
2451
  - lib/openstudio-standards/standards/necb/NECB2015/data/max_pump_power.json
2455
2452
  - lib/openstudio-standards/standards/necb/NECB2015/data/schedules.json
2456
2453
  - lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json
2454
+ - lib/openstudio-standards/standards/necb/NECB2015/data/surface_thermal_transmittance.json
2457
2455
  - lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json
2458
2456
  - lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb
2459
2457
  - lib/openstudio-standards/standards/necb/NECB2015/lighting.rb
@@ -2484,19 +2482,14 @@ files:
2484
2482
  - lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb
2485
2483
  - lib/openstudio-standards/standards/necb/README.md
2486
2484
  - lib/openstudio-standards/standards/necb/common/bc_step_code_indicators.md
2487
- - lib/openstudio-standards/standards/necb/common/btap_analysis.rb
2488
- - lib/openstudio-standards/standards/necb/common/btap_data.rb
2489
- - lib/openstudio-standards/standards/necb/common/btap_datapoint.rb
2490
2485
  - lib/openstudio-standards/standards/necb/common/construction_defaults.osm
2491
2486
  - lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv
2492
2487
  - lib/openstudio-standards/standards/necb/common/national_carbon_price_sched_feb_2025.json
2493
2488
  - lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv
2494
- - lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv
2495
2489
  - lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv
2496
2490
  - lib/openstudio-standards/standards/necb/common/phius.md
2497
2491
  - lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json
2498
2492
  - lib/openstudio-standards/standards/necb/common/system_types.yaml
2499
- - lib/openstudio-standards/standards/necb/common/utility_pricing_2025-02-20.csv
2500
2493
  - lib/openstudio-standards/standards/necb/docs/air_system_names_method.md
2501
2494
  - lib/openstudio-standards/standards/oeesc/oeesc.rb
2502
2495
  - lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb
@@ -2543,7 +2536,7 @@ required_rubygems_version: !ruby/object:Gem::Requirement
2543
2536
  - !ruby/object:Gem::Version
2544
2537
  version: 1.3.6
2545
2538
  requirements: []
2546
- rubygems_version: 3.5.17
2539
+ rubygems_version: 3.4.10
2547
2540
  signing_key:
2548
2541
  specification_version: 4
2549
2542
  summary: Creates OpenStudio models of typical buildings, creates standard baselines
@@ -1,90 +0,0 @@
1
- thermal_bridging_id,edge_type,wall_reference,description,quality,u_w_per_m_k,betb_description,material_opaque_id_layers,id_layers_quantity_multipliers,Reference
2
- 1,rimjoist,BTAP-ExteriorWall-SteelFramed-4,Concrete Slab Edge at Exterior Insulated Steel Framed Wall and Metal Panel Cladding,bad,0.17,"sim. BETB 5.2.13, metal thru-wall flashing at slab edge",139,10,* confirm that sheet metal flashing 139 call-out is 1/10 lft
3
- 2,rimjoist,BTAP-ExteriorWall-SteelFramed-4,Concrete Slab Edge at Exterior Insulated Steel Framed Wall and Metal Panel Cladding,good,0.017,"BETB 5.2.17, no thru-wall flashing, thermal clips over slab edge",172,0.5,
4
- 3,rimjoist,BTAP-ExteriorWall-SteelFramed-2,Concrete Slab Edge at Split Insulated Steel Framed Wall and Metal Panel Cladding,bad,0.28,"sim. To BETB 5.2.19, metal thru-wall flashing at slab edge",139,10,
5
- 4,rimjoist,BTAP-ExteriorWall-SteelFramed-2,Concrete Slab Edge at Split Insulated Steel Framed Wall and Metal Panel Cladding,good,0.09,"BETB 5.2.35 no thru-wall flashing, thermal clips over slab edge",172,0.5,
6
- 5,rimjoist,BTAP-ExteriorWall-SteelFramed-5,Brick Shelf Angle at Concrete Slab Edge on Exterior Insulated Steel Framed Wall,bad,0.6,"BETB 5.2.33, continuous shelf angle on slab edge ","21,172","1.0,25",
7
- 6,rimjoist,BTAP-ExteriorWall-SteelFramed-5,Brick Shelf Angle at Concrete Slab Edge on Exterior Insulated Steel Framed Wall,good,0.1,"BETB 5.2.33, stand-off shelf angel (Fero Fast Angle Bracket)","189,172","1.0,0.5",
8
- 7,rimjoist,BTAP-ExteriorWall-SteelFramed-3,Brick Veneer Shelf Angle at Concrete Slab Edge on Split Insulated Steel Framed Wall,bad,0.52,"BETB 5.2.33, continuous shelf angle on slab edge ","21,172","1.0,0.25",
9
- 8,rimjoist,BTAP-ExteriorWall-SteelFramed-3,Brick Veneer Shelf Angle at Concrete Slab Edge on Split Insulated Steel Framed Wall,good,0.1,"BETB 5.2.33, stand-off shelf angel (Fero Fast Angle Bracket)","189,172","1.0,0.5",
10
- 9,rimjoist,BTAP-ExteriorWall-WoodFramed-6,"Rim Joist and TWF, Split Insulated Wood Framed Wall with Metal Panel Cladding",bad,0.09,"BETB 8.2.1, metal thru-wall flashing at rim joist",139,1,
11
- 10,rimjoist,BTAP-ExteriorWall-WoodFramed-6,"Rim Joist and TWF, Split Insulated Wood Framed Wall with Metal Panel Cladding",good,0.026,"BETB 8.2.18 no thru-wall flashing, thermal clips over rim joist",172,0.5,
12
- 11,rimjoist,BTAP-ExteriorWall-WoodFramed-7,"Brick Veneer Shelf Angle at Rim Joist, Split Insulated Wood Framed WalL",bad,0.05,"BETB 8.2.12, continuous shelf angle on rim joist","21,172","1.0,25",
13
- 12,rimjoist,BTAP-ExteriorWall-WoodFramed-7,"Brick Veneer Shelf Angle at Rim Joist, Split Insulated Wood Framed WalL",good,0.03,"BETB 8.2.15, offset shelft angle and membrane TWF","189,172","1.0,0.5",
14
- 13,rimjoist,BTAP-ExteriorWall-Mass-8,Precast Concrete Panels Intermediate Floor Edge Connection,bad,0.2,"BETB 7.2.8, intermediate floor connection",0,1,
15
- 14,rimjoist,BTAP-ExteriorWall-Mass-8,Precast Concrete Panels Intermediate Floor Edge Connection,good,0.02,"BETB 7.2.13, intermediate floor with FRP composite connection ",0,1,
16
- 15,rimjoist,BTAP-ExteriorWall-Metal-1,Insulated Metal Sandwich Panels Intermediate Floor Edge Connection,bad,0.32,"BETB 6.2.1, horizontal panel stack joint aligned/connected to interior beam",0,1,
17
- 16,rimjoist,BTAP-ExteriorWall-Metal-1,Insulated Metal Sandwich Panels Intermediate Floor Edge Connection,good,0.03,"BETB 6.2.2, vertical panel stak joint not aligned/connected to interior beam",0,1,
18
- 17,rimjoist,BTAP-ExteriorWall-Mass-2,Brick Veneer Shelf Angle at Exterior Insulated CMU Wall ,bad,0.47,"BETB 7.2.14, continuous angle on slab edge","21,172","1.0,25",
19
- 18,rimjoist,BTAP-ExteriorWall-Mass-2,Brick Veneer Shelf Angle at Exterior Insulated CMU Wall ,good,0.1,"BETB 5.2.33, stand-off shelf angel (Fero Fast Angle Bracket)","189,172","1.0,0.5",
20
- 19,parapet,BTAP-ExteriorWall-SteelFramed-4,"Exterior Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",bad,0.7,"BETB 5.5.12, exposed concrete parapet on concrete slab, over ext. ins. Steel stud Wall",0,1,"* parapet area needs to be included in wall area calc (3ft 6"" parapet)"
21
- 20,parapet,BTAP-ExteriorWall-SteelFramed-4,"Exterior Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",good,0.43,"BETB 5.5.2, insulation wrapped concrete parapet on conc. Slab, over ext. ins. Steel stud wall","57,139","3.3,1.0",
22
- 21,parapet,BTAP-ExteriorWall-SteelFramed-4,"Exterior Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",Best,0.2,"BETB 5.5.16, structurally thermally broken concrete parapet on concrete slab, over ext. ins. SS wall",206,1,
23
- 22,parapet,BTAP-ExteriorWall-SteelFramed-5,"Exterior Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",bad,0.7,"BETB 5.5.12, exposed concrete parapet on concrete slab, over ext. ins. Steel stud Wall",0,1,"* parapet area needs to be included in wall area calc (3ft 6"" parapet)"
24
- 23,parapet,BTAP-ExteriorWall-SteelFramed-5,"Exterior Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",good,0.43,"BETB 5.5.2, insulation wrapped concrete parapet on conc. Slab, over ext. ins. Steel stud wall","57,139","3.3,1.0",
25
- 24,parapet,BTAP-ExteriorWall-SteelFramed-5,"Exterior Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",Best,0.2,"BETB 5.5.16, structurally thermally broken concrete parapet on concrete slab, over ext. ins. SS wall",206,1,
26
- 25,parapet,BTAP-ExteriorWall-SteelFramed-2,"Split Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",bad,0.65,"BETB 5.5.13, exposed concrete parapet on concrete slab over split ins. SS wall",0,1,"* parapet area needs to be included in wall area calc (3ft 6"" parapet)"
27
- 26,parapet,BTAP-ExteriorWall-SteelFramed-2,"Split Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",good,0.35,"BETB 5.5.4, insulation wrapped concrete parapet on concrete slab over split ins. SS wall","57,139","3.3,1.0",
28
- 27,parapet,BTAP-ExteriorWall-SteelFramed-2,"Split Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",Best,0.1,"BETB 5.5.17, structurally thermally broken concrete parapet on concrete slab, over split. ins. SS wall",206,1,
29
- 28,parapet,BTAP-ExteriorWall-SteelFramed-3,"Split Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",bad,0.65,"BETB 5.5.13, exposed concrete parapet on concrete slab over split ins. SS wall",0,1,"* parapet area needs to be included in wall area calc (3ft 6"" parapet)"
30
- 29,parapet,BTAP-ExteriorWall-SteelFramed-3,"Split Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",good,0.35,"BETB 5.5.4, insulation wrapped concrete parapet on concrete slab over split ins. SS wall","57,139","3.3,1.0",
31
- 30,parapet,BTAP-ExteriorWall-SteelFramed-3,"Split Insulated Steel Framed Wall to Parapet Transition, Cladding or Brick Veneer",Best,0.1,"BETB 5.5.17, structurally thermally broken concrete parapet on concrete slab, over split. ins. SS wall",206,1,
32
- 31,parapet,BTAP-ExteriorWall-WoodFramed-6,"Split Insulated Wood Framed Wall to Roof Transition, cladding or brick veneer",Fair,0.05,"BETB 8.4.1, low slope roof to vented wood framed parapet transition",0,1,"* parapet area needs to be included in wall area calc (3ft 6"" parapet)"
33
- 32,parapet,BTAP-ExteriorWall-WoodFramed-6,"Split Insulated Wood Framed Wall to Roof Transition, cladding or brick veneer",Fair,0.07,"BETB 8.4.2, truss roof to wall transition, ceiling insulation reduced at wall",190,0.5,
34
- 33,parapet,BTAP-ExteriorWall-WoodFramed-7,"Split Insulated Wood Framed Wall to Roof Transition, cladding or brick veneer",Fair,0.05,"BETB 8.4.1, low slope roof to vented wood framed parapet transition",0,1,"* parapet area needs to be included in wall area calc (3ft 6"" parapet)"
35
- 34,parapet,BTAP-ExteriorWall-WoodFramed-7,"Split Insulated Wood Framed Wall to Roof Transition, cladding or brick veneer",Fair,0.07,"BETB 8.4.2, truss roof to wall transition, ceiling insulation reduced at wall",190,0.5,
36
- 35,parapet,BTAP-ExteriorWall-Mass-2,"Exterior Insulated CMU Wall to Parapet Transition, Cladding or Brick Veneer",bad,0.5,"BETB 7.5.11, exposed CMU parapet on concrete slab over CMU wall",0,1,"* parapet area needs to be included in wall area calc (3ft 6"" parapet)"
37
- 36,parapet,BTAP-ExteriorWall-Mass-2,"Exterior Insulated CMU Wall to Parapet Transition, Cladding or Brick Veneer",good,0.23,"BETB 7.5.12, insulation wrapped CMU parapet on concrete slab over Cmu wall","57,139","3.3,1.0",
38
- 37,parapet,BTAP-ExteriorWall-Mass-10,"Exterior Insulated CMU Wall to Parapet Transition, Cladding or Brick Veneer",bad,0.5,"BETB 7.5.11, exposed CMU parapet on concrete slab over CMU wall",0,1,"* parapet area needs to be included in wall area calc (3ft 6"" parapet)"
39
- 38,parapet,BTAP-ExteriorWall-Mass-10,"Exterior Insulated CMU Wall to Parapet Transition, Cladding or Brick Veneer",good,0.23,"BETB 7.5.12, insulation wrapped CMU parapet on concrete slab over Cmu wall","57,139","3.3,1.0",
40
- 39,parapet,BTAP-ExteriorWall-Metal-1,Insulated Metal Sandwich Panels Interface with Parapet,bad,0.49,"BETB 6.4.1, vertical metal panel at steel deck with OWSJ",0,1,"* parapet area needs to be included in wall area calc (3ft 6"" parapet)"
41
- 40,parapet,BTAP-ExteriorWall-Metal-1,Insulated Metal Sandwich Panels Interface with Parapet,bad,0.42,"BETB 6.4.2, horizontal metal panel at steel deck with OWSJ",0,1,
42
- 41,parapet,BTAP-ExteriorWall-Metal-1,Insulated Metal Sandwich Panels Interface with Parapet,Fair,0.35,insulation wrapped parapet,"57,139","3.3,1.0",
43
- 42,parapet,BTAP-ExteriorWall-Mass-8,Precast Concrete Panels Interface with Parapet,bad,0.65,"BETB 7.5.4, exposed steel framed parapet inboard (roof side) of panel",0,,"* parapet area needs to be included in wall area calc (3ft 6"" parapet)"
44
- 43,parapet,BTAP-ExteriorWall-Mass-8,Precast Concrete Panels Interface with Parapet,good,0.24,insulation wrapped parapet,"57,139","3.3,1.0",
45
- 44,corner,BTAP-ExteriorWall-SteelFramed-2,"Exterior or Split Insulated Steel Framed Wall, or Exterior Insulated Concrete Wall, Corner Detail",bad,0.15,"BETB 5.6.3, continuous exterior horizontal metal girts",0,1,
46
- 45,corner,BTAP-ExteriorWall-SteelFramed-3,"Exterior or Split Insulated Steel Framed Wall, or Exterior Insulated Concrete Wall, Corner Detail",bad,0.15,"BETB 5.6.3, continuous exterior horizontal metal girts",0,1,
47
- 46,corner,BTAP-ExteriorWall-SteelFramed-4,"Exterior or Split Insulated Steel Framed Wall, or Exterior Insulated Concrete Wall, Corner Detail",bad,0.15,"BETB 5.6.3, continuous exterior horizontal metal girts",0,1,
48
- 47,corner,BTAP-ExteriorWall-SteelFramed-5,"Exterior or Split Insulated Steel Framed Wall, or Exterior Insulated Concrete Wall, Corner Detail",bad,0.15,"BETB 5.6.3, continuous exterior horizontal metal girts",0,1,
49
- 48,corner,BTAP-ExteriorWall-Mass-2,"Exterior or Split Insulated Steel Framed Wall, or Exterior Insulated Concrete Wall, Corner Detail",bad,0.15,"BETB 5.6.3, continuous exterior horizontal metal girts",0,1,
50
- 49,corner,BTAP-ExteriorWall-Mass-10,"Exterior or Split Insulated Steel Framed Wall, or Exterior Insulated Concrete Wall, Corner Detail",good,0.09,"BETB 5.6.1, thermally broken cladding attachment",0,1,
51
- 50,corner,BTAP-ExteriorWall-WoodFramed-6,"Split Insulated Wood Framed Wall, Corner Detail",good,0.04,"BETB 8.5.1, wood framed w/ continuous strapping fastened through ins.",0,1,
52
- 51,corner,BTAP-ExteriorWall-WoodFramed-7,"Split Insulated Wood Framed Wall, Corner Detail",good,0.04,"BETB 8.5.1, wood framed w/ continuous strapping fastened through ins.",0,1,
53
- 52,corner,BTAP-ExteriorWall-WoodFramed-8,"Split Insulated Wood Framed Wall, Corner Detail",good,0.04,"BETB 8.5.1, wood framed w/ continuous strapping fastened through ins.",0,1,
54
- 53,corner,BTAP-ExteriorWall-Metal-1,"Insulated Metal Sandwich Panels, Corner Detail",bad,0.15,"BETB 6.5.1, vertical panels supported at corner post",191,1,
55
- 54,corner,BTAP-ExteriorWall-Metal-1,"Insulated Metal Sandwich Panels, Corner Detail",good,0.07,"BETB 6.5.2, horizontal panels supported at corner post",191,1,
56
- 55,corner,BTAP-ExteriorWall-Mass-8,"Precast Concrete Panel, Corner Detail",bad,0.37,"BETB 7.1.8, vertical joint with concrete panel joint",141,1,
57
- 56,corner,BTAP-ExteriorWall-Mass-8,"Precast Concrete Panel, Corner Detail",good,0.16,"BETB 7.1.9, vertical joint, tigerloc thermal break or insulation completely to panel edge ",141,1.25,
58
- 57,grade,BTAP-ExteriorWall-SteelFramed-4,Exterior Insulated Steel Framed Wall to Grade Transition ,bad,0.7,"BETB 7.7.3, uninsulated foundation wall",139,0.75,
59
- 58,grade,BTAP-ExteriorWall-SteelFramed-4,Exterior Insulated Steel Framed Wall to Grade Transition ,good,0.5,"BETB 5.8.2, exterior insulated foundation wall","192,139",0.5.0.75,
60
- 59,grade,BTAP-ExteriorWall-SteelFramed-2,Split Insulated Steel Framed Wall to Grade Transition,bad,0.72,"BETB 7.7.3, uninsulated foundation wall",139,,
61
- 60,grade,BTAP-ExteriorWall-SteelFramed-2,Split Insulated Steel Framed Wall to Grade Transition,good,0.47,"BETB 5.8.3, exterior insulated foundation wall","192,139","1.0,1.0",
62
- 61,grade,BTAP-ExteriorWall-SteelFramed-5,Exterior Insulated Wall with Brick Veneer to Grade Transition,bad,0.52,"BETB 7.7.9, shelf angle on concrete foundation, uninsulated foundation wall","21,139","1.0,0.5",
63
- 62,grade,BTAP-ExteriorWall-SteelFramed-5,Exterior Insulated Wall with Brick Veneer to Grade Transition,good,0.09,"BETB 5.2.33, fero-angle on concrete foundation , exteiror insulated foundation wall","189,139,192","1.0,0.5,0.5",
64
- 63,grade,BTAP-ExteriorWall-SteelFramed-3,Split Insulated Wall with Brick Veneer to Grade Transition,bad,0.55,"BETB 7.7.9, shelf angle on concrete foundation, uninsulated foundation wall","21,139","1.0,0.5",
65
- 64,grade,BTAP-ExteriorWall-SteelFramed-3,Split Insulated Wall with Brick Veneer to Grade Transition,good,0.09,"BETB 5.2.33, fero-angle on concrete foundation , exteiror insulated foundation wall","189,139,192","1.0,0.5,0.5",
66
- 65,grade,BTAP-ExteriorWall-WoodFramed-7,Split Insulated Wall with Brick Veneer to Grade Transition,bad,0.55,"BETB 7.7.9, shelf angle on concrete foundation, uninsulated foundation wall","21,139","1.0,0.5",
67
- 66,grade,BTAP-ExteriorWall-WoodFramed-7,Split Insulated Wall with Brick Veneer to Grade Transition,good,0.09,"BETB 5.2.33, fero-angle on concrete foundation , exteiror insulated foundation wall","189,139,192","1.0,0.5,0.5",
68
- 67,grade,BTAP-ExteriorWall-WoodFramed-6,Split Insulated Wood Framed Wall to Grade Transition,bad,0.52,"BETB 8.7.1, flashing attached to concrete foundation wall, with or without exterior insulation on foundation","139,192","0.5,0.5",
69
- 68,grade,BTAP-ExteriorWall-WoodFramed-6,Split Insulated Wood Framed Wall to Grade Transition,good,0.09,"BETB 8.6.2, flashing on rim joist, interior or exterior insulated foundation wall","139,192","0.5,0.5",
70
- 69,grade,BTAP-ExteriorWall-Metal-1,Insulated Metal Sandwich Panels to Grade Transition,bad,0.7,"BETB 7.7.3, similar to exterior insulated wall, uninsulated foundation wall",139,0.5,
71
- 70,grade,BTAP-ExteriorWall-Metal-1,Insulated Metal Sandwich Panels to Grade Transition,good,0.5,"BETB 5.8.2, simiar to exterior insulated wall, insulated foundation wall","192,139","0.5,0.5",
72
- 71,grade,BTAP-ExteriorWall-Mass-8,Precast Concrete Panels to Grade Transition,bad,0.8,"BETB 7.7.3, uninsulated foundation wall",139,0.5,
73
- 72,grade,BTAP-ExteriorWall-Mass-8,Precast Concrete Panels to Grade Transition,good,0.32,"BETB 7.7.4, ext. insulated foundation wall aligned with panel insulation","192,139","0.5,0.5",
74
- 73,fenestration,BTAP-ExteriorWall-SteelFramed-4,"Exterior Insulated Steel Framed or Concrete Wall, Window Perimeter Interface",bad,0.35,"BETB 5.3.14, ext. insulated, thermal clips, windows aligned with framing/opening",139,0.75,
75
- 74,fenestration,BTAP-ExteriorWall-SteelFramed-4,"Exterior Insulated Steel Framed or Concrete Wall, Window Perimeter Interface",good,0.078,"BETB 5.3.12, ext. insulated, thermal clips, windows aligned with insulation",139,0.5,
76
- 75,fenestration,BTAP-ExteriorWall-Mass-10,"Exterior Insulated Steel Framed or Concrete Wall, Window Perimeter Interface",bad,0.35,"BETB 5.3.14, ext. insulated, thermal clips, windows aligned with framing/opening",139,0.75,
77
- 76,fenestration,BTAP-ExteriorWall-Mass-10,"Exterior Insulated Steel Framed or Concrete Wall, Window Perimeter Interface",good,0.078,"BETB 5.3.12, ext. insulated, thermal clips, windows aligned with insulation",139,0.5,
78
- 77,fenestration,BTAP-ExteriorWall-SteelFramed-2,"Split Insulated Framed Wall, Window Perimeter Interface",bad,0.27,"BETB 5.3.15, split insulated, thermal clips, windows aligned with framing/opening",139,0.75,
79
- 78,fenestration,BTAP-ExteriorWall-SteelFramed-2,"Split Insulated Framed Wall, Window Perimeter Interface",good,0.078,"BETB 5.3.13, split insulated, thermal clips, windows aligned with insulation",139,0.5,
80
- 79,fenestration,BTAP-ExteriorWall-WoodFramed-6,"Split Insulated Framed Wall, Window Perimeter Interface",bad,0.27,"BETB 5.3.15, split insulated, thermal clips, windows aligned with framing/opening",139,0.75,
81
- 80,fenestration,BTAP-ExteriorWall-WoodFramed-6,"Split Insulated Framed Wall, Window Perimeter Interface",good,0.078,"BETB 5.3.13, split insulated, thermal clips, windows aligned with insulation",139,0.5,
82
- 81,fenestration,BTAP-ExteriorWall-WoodFramed-7,"Exterior Insulated Wall with Brick Veneer, Window Perimeter Interface",bad,0.27,"BETB 7.3.14,brick fully interupts exterior insulation at window perimeter returns",0,1,
83
- 82,fenestration,BTAP-ExteriorWall-WoodFramed-7,"Exterior Insulated Wall with Brick Veneer, Window Perimeter Interface",good,0.078,"BETB 7.3.15, brick partially interupts exterior insulation at window perimeter return (ie. At least 1"" ext. is maintained)",0,1,
84
- 83,fenestration,BTAP-ExteriorWall-Metal-1,"Insulated Metal Sandwich Panels, Window Perimeter Interface",bad,0.52,"BETB 6.3.1, metal closure fully bypasses window thermal break",139,1,
85
- 84,fenestration,BTAP-ExteriorWall-Metal-1,"Insulated Metal Sandwich Panels, Window Perimeter Interface",good,0.078,"BETB 5.3.12, similar to good steel stud opening, metal closure does not bypass thermal break",139,0.5,
86
- 85,fenestration,BTAP-ExteriorWall-Mass-8,"Precast Concrete Panels, Window Perimeter Interface",Fair,0.06,"BETB 7.3.5, panel insulation brought to panel edge, window aligned with insulation",139,0.25,
87
- 86,fenestration,BTAP-ExteriorWall-Mass-8,"Precast Concrete Panels, Window Perimeter Interface",Fair,0.078,"BETB 7.4.5, conrete panel edge, thermal break at window perimeter, window aligned with insulation","139,150","0.25,0.083333",
88
- 87,roof_curbs,BTAP-EXTERIOR ROOF-IEAD4,"Concrete Planter Walls or Curbs, Linear Transmittance",bad,0.87,"BETB 10.2.2, exposed concrete planter wall or curb continuously attached to roof, bypassing roof insulation (assumes. 3 ft high planter)","193,113,47","6.5,1.5,6.5",
89
- 88,roof_curbs,BTAP-EXTERIOR ROOF-IEAD4,"Concrete Planter Walls or Curbs, Linear Transmittance",good,0,"BETB 10.2.3, floating planter wall/curb on top of insulation","194,193,113,47","1.5,4.5,1.25,4.5",
90
- 44,corner,BTAP-ExteriorWall-SteelFramed-2,"Exterior or Split Insulated Steel Framed Wall, or Exterior Insulated Concrete Wall, Corner Detail",good,0.15,"BETB 5.6.3, continuous exterior horizontal metal girts",0,1,