openstudio-standards 0.7.1 → 0.8.0.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (362) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAE90120162019LargeHotel.json +58 -13
  3. data/data/geometry/ASHRAELargeHotel.json +58 -13
  4. data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
  5. data/data/standards/export_OpenStudio_libraries.rb +2 -2
  6. data/data/standards/manage_OpenStudio_Standards.rb +6 -6
  7. data/data/standards/openstudio_standards_duplicates_log.csv +7961 -1
  8. data/data/standards/test_performance_expected_dd_results.csv +2016 -2004
  9. data/lib/openstudio-standards/btap/fileio.rb +171 -5
  10. data/lib/openstudio-standards/constructions/create.rb +38 -4
  11. data/lib/openstudio-standards/constructions/modify.rb +10 -3
  12. data/lib/openstudio-standards/create_typical/create_typical.rb +42 -28
  13. data/lib/openstudio-standards/create_typical/space_type_information.rb +160 -0
  14. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +16 -19
  15. data/lib/openstudio-standards/exterior_lighting/create.rb +454 -0
  16. data/lib/openstudio-standards/exterior_lighting/data/entryways.csv +52 -0
  17. data/lib/openstudio-standards/exterior_lighting/data/parking.csv +54 -0
  18. data/lib/openstudio-standards/exterior_lighting/data/typical_exterior_lighting.json +37 -0
  19. data/lib/openstudio-standards/exterior_lighting/information.rb +202 -0
  20. data/lib/openstudio-standards/geometry/information.rb +49 -2
  21. data/lib/openstudio-standards/hvac/components/create.rb +169 -0
  22. data/lib/openstudio-standards/hvac/components/modify.rb +42 -0
  23. data/lib/openstudio-standards/hvac/exhaust/create_exhaust_fan.rb +108 -0
  24. data/lib/openstudio-standards/hvac/exhaust/data/convert_data.rb +86 -0
  25. data/lib/openstudio-standards/hvac/exhaust/data/typical_exhaust.csv +18 -0
  26. data/lib/openstudio-standards/hvac/exhaust/data/typical_exhaust.json +89 -0
  27. data/lib/openstudio-standards/infiltration/nist_infiltration.rb +25 -13
  28. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +0 -64
  29. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +0 -25
  30. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +0 -25
  31. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +1 -11
  32. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +5 -1
  33. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -7
  34. data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +36 -18
  35. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +1 -1
  36. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +121 -239
  37. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +179 -151
  38. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +0 -466
  39. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +18 -2
  40. data/lib/openstudio-standards/refrigeration/create_case.rb +125 -0
  41. data/lib/openstudio-standards/refrigeration/create_compressor.rb +78 -0
  42. data/lib/openstudio-standards/refrigeration/create_compressor_rack.rb +48 -0
  43. data/lib/openstudio-standards/refrigeration/create_refrigeration_system.rb +74 -0
  44. data/lib/openstudio-standards/refrigeration/create_typical_refrigeration.rb +161 -0
  45. data/lib/openstudio-standards/refrigeration/create_walkin.rb +116 -0
  46. data/lib/openstudio-standards/refrigeration/data/refrigerated_cases.csv +31 -0
  47. data/lib/openstudio-standards/refrigeration/data/refrigerated_walkins.csv +76 -0
  48. data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +13 -0
  49. data/lib/openstudio-standards/refrigeration/data/typical_refrigerated_cases.csv +17 -0
  50. data/lib/openstudio-standards/refrigeration/data/typical_refrigerated_walkins.csv +53 -0
  51. data/lib/openstudio-standards/refrigeration/information.rb +130 -0
  52. data/lib/openstudio-standards/schedules/parametric.rb +1 -1
  53. data/lib/openstudio-standards/service_water_heating/create_typical.rb +299 -0
  54. data/lib/openstudio-standards/service_water_heating/create_water_heating_loop.rb +16 -14
  55. data/lib/openstudio-standards/service_water_heating/data/convert_data.rb +119 -0
  56. data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.csv +54 -0
  57. data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.json +810 -0
  58. data/lib/openstudio-standards/service_water_heating/information.rb +69 -0
  59. data/lib/openstudio-standards/sql_file/fenestration.rb +1 -1
  60. data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +154 -0
  61. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +35 -12
  62. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +110 -61
  63. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +128 -29
  64. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +103 -38
  65. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
  66. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +106 -5
  67. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +8 -8
  68. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +44 -17
  69. data/lib/openstudio-standards/standards/Standards.Fan.rb +32 -21
  70. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +45 -18
  71. data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +14 -9
  72. data/lib/openstudio-standards/standards/Standards.Model.rb +294 -76
  73. data/lib/openstudio-standards/standards/Standards.Motor.rb +66 -0
  74. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -1
  75. data/lib/openstudio-standards/standards/Standards.Pump.rb +34 -20
  76. data/lib/openstudio-standards/standards/Standards.ServiceWaterHeating.rb +0 -353
  77. data/lib/openstudio-standards/standards/Standards.Space.rb +3 -107
  78. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +2 -57
  79. data/lib/openstudio-standards/standards/Standards.Surface.rb +11 -3
  80. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +1 -120
  81. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.computer_room_acs.json +142 -0
  82. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +1006 -596
  83. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.energy_recovery.json +724 -0
  84. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +1258 -163
  85. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +1070 -140
  86. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +33 -3374
  87. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +1400 -340
  88. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.vrfs.json +769 -0
  89. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +2 -5338
  90. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.computer_room_acs.json +142 -0
  91. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +1006 -596
  92. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.energy_recovery.json +724 -0
  93. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +1258 -163
  94. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +1070 -140
  95. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +15 -3343
  96. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +1840 -372
  97. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.vrfs.json +769 -0
  98. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +20 -10
  99. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +0 -9
  100. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +0 -5382
  101. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.computer_room_acs.json +142 -0
  102. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +1006 -628
  103. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +718 -712
  104. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +1438 -163
  105. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +2552 -182
  106. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +14 -3368
  107. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +2348 -352
  108. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.vrfs.json +769 -0
  109. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +47 -61
  110. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +6 -0
  111. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Motor.rb +11 -0
  112. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +0 -9
  113. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +2 -5522
  114. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.computer_room_acs.json +142 -0
  115. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +1006 -628
  116. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +1358 -1346
  117. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +1438 -163
  118. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +1359 -189
  119. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +19 -3451
  120. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +2176 -616
  121. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.vrfs.json +616 -0
  122. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +47 -61
  123. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +9 -0
  124. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Motor.rb +11 -0
  125. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +0 -9
  126. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +8 -6055
  127. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.computer_room_acs.json +142 -0
  128. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.economizers.json +1006 -628
  129. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +1188 -1424
  130. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ext_ltg.json +1498 -163
  131. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.motors.json +1769 -189
  132. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +15 -3422
  133. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +1807 -408
  134. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.vrfs.json +1024 -0
  135. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +70 -87
  136. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +9 -0
  137. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Motor.rb +11 -0
  138. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +0 -9
  139. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +8 -6080
  140. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.computer_room_acs.json +142 -0
  141. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.economizers.json +1006 -628
  142. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2806 -3296
  143. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ext_ltg.json +1558 -163
  144. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.motors.json +1759 -189
  145. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +16 -3448
  146. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +2758 -422
  147. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.vrfs.json +684 -0
  148. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +14 -3318
  149. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +2 -4786
  150. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.chillers.json +1 -1
  151. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +953 -207
  152. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.energy_recovery.json +724 -0
  153. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.ext_ltg.json +5 -5
  154. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +11 -2858
  155. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirConditionerVariableRefrigerantFlow.rb +13 -0
  156. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +0 -18
  157. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +1 -4739
  158. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.chillers.json +0 -51
  159. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +953 -207
  160. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.energy_recovery.json +724 -0
  161. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.ext_ltg.json +5 -5
  162. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +9 -2830
  163. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirConditionerVariableRefrigerantFlow.rb +13 -0
  164. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +0 -18
  165. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.economizers.json +1006 -564
  166. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.energy_recovery.json +1264 -0
  167. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.ext_ltg.json +5 -5
  168. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.spc_typ.json +0 -1079
  169. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +132 -288
  170. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +44 -20
  171. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +11 -0
  172. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +0 -8
  173. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.economizers.json +1006 -564
  174. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.energy_recovery.json +1264 -0
  175. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.ext_ltg.json +5 -5
  176. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json +0 -1079
  177. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +137 -288
  178. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +44 -20
  179. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +11 -0
  180. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +0 -9
  181. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +12 -10
  182. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +8 -6
  183. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +8 -6
  184. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +9 -3
  185. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Fan.rb +6 -40
  186. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +30 -337
  187. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +4 -5
  188. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -2
  189. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +56 -3
  190. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +80 -0
  191. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +0 -10
  192. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +35 -0
  193. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.economizers.json +550 -0
  194. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.energy_recovery.json +724 -0
  195. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.ext_ltg.json +1216 -0
  196. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps.json +5 -5
  197. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.motors.json +225 -245
  198. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.unitary_acs.json +174 -78
  199. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.water_heaters.json +354 -317
  200. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +19 -3
  201. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_airloop_hvac.json +185 -0
  202. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_airloop_hvac_doas.json +127 -0
  203. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_building.json +121 -0
  204. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_design_specification_outdoor_air.json +49 -0
  205. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_electric_equipment.json +113 -0
  206. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_exterior_lights.json +120 -0
  207. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_space.json +388 -0
  208. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_spacetype.json +367 -0
  209. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_thermal_zone.json +56 -0
  210. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_wateruse_connections.json +37 -0
  211. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_wateruse_equipment.json +69 -0
  212. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_wateruse_equipment_definition.json +37 -0
  213. data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/data/cbes_pre_1978.ext_ltg.json +5 -5
  214. data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/data/cbes_t24_1978.ext_ltg.json +5 -5
  215. data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/data/cbes_t24_1992.ext_ltg.json +5 -5
  216. data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/data/cbes_t24_2001.ext_ltg.json +5 -5
  217. data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/data/cbes_t24_2005.ext_ltg.json +5 -5
  218. data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/data/cbes_t24_2008.ext_ltg.json +5 -5
  219. data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +5 -5
  220. data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.ext_ltg.json +5 -5
  221. data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +5 -5
  222. data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.ext_ltg.json +5 -5
  223. data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +5 -5
  224. data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.ext_ltg.json +5 -5
  225. data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +5 -5
  226. data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.ext_ltg.json +5 -5
  227. data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +5 -5
  228. data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.ext_ltg.json +5 -5
  229. data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +5 -5
  230. data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.ext_ltg.json +5 -5
  231. data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +5 -5
  232. data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.ext_ltg.json +5 -5
  233. data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +5 -5
  234. data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.ext_ltg.json +5 -5
  235. data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/data/comstock_deer_2020.ext_ltg.json +5 -5
  236. data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.ext_ltg.json +5 -5
  237. data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/data/comstock_deer_2025.ext_ltg.json +5 -5
  238. data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.ext_ltg.json +5 -5
  239. data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/data/comstock_deer_2030.ext_ltg.json +5 -5
  240. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.ext_ltg.json +5 -5
  241. data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/data/comstock_deer_2035.ext_ltg.json +5 -5
  242. data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.ext_ltg.json +5 -5
  243. data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/data/comstock_deer_2040.ext_ltg.json +5 -5
  244. data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.ext_ltg.json +5 -5
  245. data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/data/comstock_deer_2045.ext_ltg.json +5 -5
  246. data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.ext_ltg.json +5 -5
  247. data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/data/comstock_deer_2050.ext_ltg.json +5 -5
  248. data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.ext_ltg.json +5 -5
  249. data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/data/comstock_deer_2055.ext_ltg.json +5 -5
  250. data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.ext_ltg.json +5 -5
  251. data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/data/comstock_deer_2060.ext_ltg.json +5 -5
  252. data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.ext_ltg.json +5 -5
  253. data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/data/comstock_deer_2065.ext_ltg.json +5 -5
  254. data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.ext_ltg.json +5 -5
  255. data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/data/comstock_deer_2070.ext_ltg.json +5 -5
  256. data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.ext_ltg.json +5 -5
  257. data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/data/comstock_deer_2075.ext_ltg.json +5 -5
  258. data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.ext_ltg.json +5 -5
  259. data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +5 -5
  260. data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.ext_ltg.json +5 -5
  261. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +10 -1
  262. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/unitary_acs.json +20 -20
  263. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +379 -27
  264. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +1 -4
  265. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +0 -1
  266. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +1 -1
  267. data/lib/openstudio-standards/standards/necb/NECB2011/data/unitary_acs.json +20 -20
  268. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +34 -22
  269. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +76 -23
  270. data/lib/openstudio-standards/standards/necb/NECB2011/necb_shw_calculation.xlsx +0 -0
  271. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -5
  272. data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +6 -2
  273. data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +26 -24
  274. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +2 -1
  275. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +38 -32
  276. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +215 -18
  277. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +190 -15
  278. data/lib/openstudio-standards/standards/necb/common/national_carbon_price_sched_feb_2025.json +60 -0
  279. data/lib/openstudio-standards/standards/necb/common/utility_pricing_2025-02-20.csv +92 -0
  280. data/lib/openstudio-standards/utilities/ruleset_check.rb +204 -0
  281. data/lib/openstudio-standards/version.rb +1 -1
  282. data/lib/openstudio-standards/weather/information.rb +1 -1
  283. data/lib/openstudio-standards.rb +32 -12
  284. metadata +78 -80
  285. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +0 -13
  286. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +0 -13
  287. data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +0 -13
  288. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +0 -432
  289. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +0 -11
  290. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +0 -169
  291. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ref_cases.json +0 -1456
  292. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ref_lnup.json +0 -562
  293. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +0 -20804
  294. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +0 -11
  295. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +0 -169
  296. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ref_cases.json +0 -1456
  297. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ref_lnup.json +0 -562
  298. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +0 -169
  299. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ref_cases.json +0 -1456
  300. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ref_lnup.json +0 -562
  301. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +0 -169
  302. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ref_cases.json +0 -1456
  303. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ref_lnup.json +0 -562
  304. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +0 -169
  305. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ref_cases.json +0 -763
  306. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ref_lnup.json +0 -562
  307. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +0 -169
  308. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ref_cases.json +0 -763
  309. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ref_lnup.json +0 -562
  310. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +0 -169
  311. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ref_cases.json +0 -1456
  312. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ref_lnup.json +0 -562
  313. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ext_ltg.json +0 -169
  314. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ref_cases.json +0 -1456
  315. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ref_lnup.json +0 -562
  316. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_economizers.json +0 -213
  317. data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +0 -11
  318. data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +0 -11
  319. data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +0 -11
  320. data/lib/openstudio-standards/standards/deer/deer.Space.rb +0 -20
  321. data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.ref_cases.json +0 -1456
  322. data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.ref_lnup.json +0 -562
  323. data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.ref_cases.json +0 -1456
  324. data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.ref_lnup.json +0 -562
  325. data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.ref_cases.json +0 -1456
  326. data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.ref_lnup.json +0 -562
  327. data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.ref_cases.json +0 -1456
  328. data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.ref_lnup.json +0 -562
  329. data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.ref_cases.json +0 -1456
  330. data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.ref_lnup.json +0 -562
  331. data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.ref_cases.json +0 -1456
  332. data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.ref_lnup.json +0 -562
  333. data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.ref_cases.json +0 -1456
  334. data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.ref_lnup.json +0 -562
  335. data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.ref_cases.json +0 -1456
  336. data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.ref_lnup.json +0 -562
  337. data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.ref_cases.json +0 -1456
  338. data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.ref_lnup.json +0 -562
  339. data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.ref_cases.json +0 -1456
  340. data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.ref_lnup.json +0 -562
  341. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.ref_cases.json +0 -1456
  342. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.ref_lnup.json +0 -562
  343. data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.ref_cases.json +0 -1456
  344. data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.ref_lnup.json +0 -562
  345. data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.ref_cases.json +0 -1456
  346. data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.ref_lnup.json +0 -562
  347. data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.ref_cases.json +0 -1456
  348. data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.ref_lnup.json +0 -562
  349. data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.ref_cases.json +0 -1456
  350. data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.ref_lnup.json +0 -562
  351. data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.ref_cases.json +0 -1456
  352. data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.ref_lnup.json +0 -562
  353. data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.ref_cases.json +0 -1456
  354. data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.ref_lnup.json +0 -562
  355. data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.ref_cases.json +0 -1456
  356. data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.ref_lnup.json +0 -562
  357. data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.ref_cases.json +0 -1456
  358. data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.ref_lnup.json +0 -562
  359. data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.ref_cases.json +0 -1456
  360. data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.ref_lnup.json +0 -562
  361. data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.ref_cases.json +0 -1456
  362. data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.ref_lnup.json +0 -562
@@ -84,28 +84,55 @@ module CoolingTower
84
84
  # per method used in PNNL prototype buildings.
85
85
  # Assumes that the fan brake horsepower is 90%
86
86
  # of the fan nameplate rated motor power.
87
- fan_motor_nameplate_hp = design_water_flow_gpm / min_gpm_per_hp
88
- fan_bhp = 0.9 * fan_motor_nameplate_hp
89
-
90
- # Lookup the minimum motor efficiency
87
+ # Source: Thornton et al. (2011), Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010, Section 4.5.4
88
+ nominal_hp = design_water_flow_gpm / min_gpm_per_hp
89
+ fan_bhp = 0.9 * nominal_hp
91
90
  fan_motor_eff = 0.85
92
- motors = standards_data['motors']
93
91
 
94
- # Assuming all fan motors are 4-pole Enclosed
95
- search_criteria = {
96
- 'template' => template,
97
- 'number_of_poles' => 4.0,
98
- 'type' => 'Enclosed'
99
- }
92
+ if nominal_hp <= 0.75
93
+ motor_type = motor_type(nominal_hp)
94
+ motor_properties = motor_fractional_hp_efficiencies(nominal_hp, motor_type = motor_type)
95
+ else
96
+ # Lookup the minimum motor efficiency
97
+ motors = standards_data['motors']
98
+
99
+ # Assuming all fan motors are 4-pole Enclosed
100
+ search_criteria = {
101
+ 'template' => template,
102
+ 'number_of_poles' => 4.0,
103
+ 'type' => 'Enclosed'
104
+ }
105
+
106
+ # Use the efficiency largest motor efficiency when BHP is greater than the largest size for which a requirement is provided
107
+ data = model_find_objects(motors, search_criteria)
108
+ if data.empty?
109
+ search_criteria = {
110
+ 'template' => template,
111
+ 'type' => nil
112
+ }
113
+ data = model_find_objects(motors, search_criteria)
114
+ end
115
+ maximum_capacity = model_find_maximum_value(data, 'maximum_capacity')
116
+ if fan_bhp > maximum_capacity
117
+ fan_bhp = maximum_capacity
118
+ end
119
+
120
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = Date.today, area = nil, num_floors = nil, fan_motor_bhp = fan_bhp)
121
+
122
+ if motor_properties.nil?
123
+ # Retry without the date
124
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = nil, area = nil, num_floors = nil, fan_motor_bhp = fan_bhp)
125
+ end
126
+ end
100
127
 
101
- motor_properties = model_find_object(motors, search_criteria, fan_motor_nameplate_hp)
102
128
  if motor_properties.nil?
103
- OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CoolingTower', "For #{cooling_tower.name}, could not find motor properties using search criteria: #{search_criteria}, motor_hp = #{fan_motor_nameplate_hp} hp.")
104
- return false
129
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CoolingTower', "For #{cooling_tower.name}, could not find motor properties using search criteria: #{search_criteria}, motor_hp = #{nominal_hp} hp. Using a default value of #{fan_motor_eff}.")
105
130
  end
106
131
 
107
- fan_motor_eff = motor_properties['nominal_full_load_efficiency']
108
- nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
132
+ unless motor_properties.nil?
133
+ fan_motor_eff = motor_properties['nominal_full_load_efficiency']
134
+ nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
135
+ end
109
136
  # Round to nearest whole HP for niceness
110
137
  if nominal_hp >= 2
111
138
  nominal_hp = nominal_hp.round
@@ -116,7 +143,7 @@ module CoolingTower
116
143
  # Convert to W
117
144
  fan_motor_actual_power_w = fan_motor_actual_power_hp * 745.7 # 745.7 W/HP
118
145
 
119
- OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoolingTower', "For #{cooling_tower.name}, allowed fan motor nameplate hp = #{fan_motor_nameplate_hp.round(1)} hp, fan brake horsepower = #{fan_bhp.round(1)}, and fan motor actual power = #{fan_motor_actual_power_hp.round(1)} hp (#{fan_motor_actual_power_w.round} W) at #{fan_motor_eff} motor efficiency.")
146
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoolingTower', "For #{cooling_tower.name}, allowed fan motor nameplate hp = #{nominal_hp.round(1)} hp, fan brake horsepower = #{fan_bhp.round(1)}, and fan motor actual power = #{fan_motor_actual_power_hp.round(1)} hp (#{fan_motor_actual_power_w.round} W) at #{fan_motor_eff} motor efficiency.")
120
147
 
121
148
  # Append the efficiency to the name
122
149
  cooling_tower.setName("#{cooling_tower.name} #{min_gpm_per_hp.to_f.round(1)} gpm/hp")
@@ -231,7 +231,7 @@ module Fan
231
231
 
232
232
  # Determines the minimum fan motor efficiency and nominal size for a given motor bhp.
233
233
  # This should be the total brake horsepower with any desired safety factor already included.
234
- # This method picks the next nominal motor catgory larger than the required brake horsepower,
234
+ # This method picks the next nominal motor category larger than the required brake horsepower,
235
235
  # and the efficiency is based on that size.
236
236
  # For example, if the bhp = 6.3, the nominal size will be 7.5HP and the efficiency
237
237
  # for 90.1-2010 will be 91.7% from Table 10.8B.
@@ -243,7 +243,12 @@ module Fan
243
243
  # @return [Array<Double>] minimum motor efficiency (0.0 to 1.0), nominal horsepower
244
244
  def fan_standard_minimum_motor_efficiency_and_size(fan, motor_bhp)
245
245
  fan_motor_eff = 0.85
246
- nominal_hp = motor_bhp
246
+ # Calculate the allowed fan brake horsepower
247
+ # per method used in PNNL prototype buildings.
248
+ # Assumes that the fan brake horsepower is 90%
249
+ # of the fan nameplate rated motor power.
250
+ # Source: Thornton et al. (2011), Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010, Section 4.5.4
251
+ nominal_hp = motor_bhp * 1.1
247
252
 
248
253
  # Don't attempt to look up motor efficiency
249
254
  # for zero-hp fans, which may occur when there is no
@@ -267,34 +272,40 @@ module Fan
267
272
  # In this case, use the 0.5 HP for the lookup.
268
273
  if fan_small_fan?(fan)
269
274
  nominal_hp = 0.5
270
- else
271
- motor_properties = model_find_object(motors, search_criteria, motor_bhp)
275
+
276
+ # Get the efficiency based on the nominal horsepower
277
+ motor_type = motor_type(nominal_hp)
278
+ motor_properties = motor_fractional_hp_efficiencies(nominal_hp, motor_type = motor_type)
279
+
272
280
  if motor_properties.nil?
273
- OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Fan', "For #{fan.name}, could not find motor properties using search criteria: #{search_criteria}, motor_bhp = #{motor_bhp} hp.")
281
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Fan', "For #{fan.name}, could not find nominal motor properties using search criteria: #{search_criteria}, motor_hp = #{nominal_hp} hp.")
274
282
  return [fan_motor_eff, nominal_hp]
275
283
  end
276
-
277
- nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
278
- # If the biggest fan motor size is hit, use the highest category efficiency
279
- if nominal_hp > 9998.0
280
- OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Fan', "For #{fan.name}, there is no greater nominal HP. Use the efficiency of the largest motor category.")
281
- nominal_hp = motor_bhp
284
+ else
285
+ # Use the efficiency largest motor efficiency when BHP is greater than the largest size for which a requirement is provided
286
+ data = model_find_objects(motors, search_criteria)
287
+ maximum_capacity = model_find_maximum_value(data, 'maximum_capacity')
288
+ if motor_bhp > maximum_capacity
289
+ motor_bhp = maximum_capacity
282
290
  end
283
291
 
284
- # Round to nearest whole HP for niceness
285
- if nominal_hp >= 2
286
- nominal_hp = nominal_hp.round
292
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = Date.today, area = nil, num_floors = nil, fan_motor_bhp = motor_bhp)
293
+ if motor_properties.nil?
294
+ # Retry without the date
295
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = nil, area = nil, num_floors = nil, fan_motor_bhp = motor_bhp)
296
+ if motor_properties.nil?
297
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Fan', "For #{fan.name}, could not find motor properties using search criteria: #{search_criteria}, motor_bhp = #{motor_bhp} hp.")
298
+ return [fan_motor_eff, nominal_hp]
299
+ end
287
300
  end
288
301
  end
289
302
 
290
- # Get the efficiency based on the nominal horsepower
291
- # Add 0.01 hp to avoid search errors.
292
- motor_properties = model_find_object(motors, search_criteria, nominal_hp + 0.01)
293
-
294
- if motor_properties.nil?
295
- OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Fan', "For #{fan.name}, could not find nominal motor properties using search criteria: #{search_criteria}, motor_hp = #{nominal_hp} hp.")
296
- return [fan_motor_eff, nominal_hp]
303
+ nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
304
+ # Round to nearest whole HP for niceness
305
+ if nominal_hp >= 2
306
+ nominal_hp = nominal_hp.round
297
307
  end
308
+
298
309
  fan_motor_eff = motor_properties['nominal_full_load_efficiency']
299
310
 
300
311
  return [fan_motor_eff, nominal_hp]
@@ -76,27 +76,54 @@ class Standard
76
76
  # per method used in PNNL prototype buildings.
77
77
  # Assumes that the fan brake horsepower is 90%
78
78
  # of the fan nameplate rated motor power.
79
- fan_motor_nameplate_hp = design_water_flow_gpm / min_gpm_per_hp
80
- fan_bhp = 0.9 * fan_motor_nameplate_hp
81
-
82
- # Lookup the minimum motor efficiency
83
- motors = standards_data['motors']
84
-
85
- # Assuming all fan motors are 4-pole Enclosed
86
- search_criteria = {
87
- 'template' => template,
88
- 'number_of_poles' => 4.0,
89
- 'type' => 'Enclosed'
90
- }
79
+ # Source: Thornton et al. (2011), Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010, Section 4.5.4
80
+ nominal_hp = design_water_flow_gpm / min_gpm_per_hp
81
+ fan_bhp = 0.9 * nominal_hp
82
+ fan_motor_eff = 0.85
83
+
84
+ if nominal_hp <= 0.75
85
+ motor_type = motor_type(nominal_hp)
86
+ motor_properties = motor_fractional_hp_efficiencies(nominal_hp, motor_type = motor_type)
87
+ else
88
+ # Lookup the minimum motor efficiency
89
+ motors = standards_data['motors']
90
+
91
+ # Assuming all fan motors are 4-pole Enclosed
92
+ search_criteria = {
93
+ 'template' => template,
94
+ 'number_of_poles' => 4.0,
95
+ 'type' => 'Enclosed'
96
+ }
97
+
98
+ # Use the efficiency largest motor efficiency when BHP is greater than the largest size for which a requirement is provided
99
+ data = model_find_objects(motors, search_criteria)
100
+ if data.empty?
101
+ search_criteria = {
102
+ 'template' => template,
103
+ 'type' => nil
104
+ }
105
+ data = model_find_objects(motors, search_criteria)
106
+ end
107
+ maximum_capacity = model_find_maximum_value(data, 'maximum_capacity')
108
+ if fan_bhp > maximum_capacity
109
+ fan_bhp = maximum_capacity
110
+ end
111
+
112
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = Date.today, area = nil, num_floors = nil, fan_motor_bhp = fan_bhp)
113
+ if motor_properties.nil?
114
+ # Retry without the date
115
+ motor_properties = model_find_object(motors, search_criteria, capacity = nil, date = nil, area = nil, num_floors = nil, fan_motor_bhp = fan_bhp)
116
+ end
117
+ end
91
118
 
92
- motor_properties = model_find_object(motors, search_criteria, fan_motor_nameplate_hp)
93
119
  if motor_properties.nil?
94
- OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.FluidCooler', "For #{fluid_cooler.name}, could not find motor properties using search criteria: #{search_criteria}, motor_hp = #{motor_hp} hp.")
95
- return false
120
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.FluidCooler', "For #{fluid_cooler.name}, could not find motor properties using search criteria: #{search_criteria}, motor_hp = #{norminal_hp} hp. Using a default value of #{fan_motor_eff}.")
96
121
  end
97
122
 
98
- fan_motor_eff = motor_properties['nominal_full_load_efficiency']
99
- nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
123
+ unless motor_properties.nil?
124
+ fan_motor_eff = motor_properties['nominal_full_load_efficiency']
125
+ nominal_hp = motor_properties['maximum_capacity'].to_f.round(1)
126
+ end
100
127
  # Round to nearest whole HP for niceness
101
128
  if nominal_hp >= 2
102
129
  nominal_hp = nominal_hp.round
@@ -107,7 +134,7 @@ class Standard
107
134
  # Convert to W
108
135
  fan_motor_actual_power_w = fan_motor_actual_power_hp * 745.7 # 745.7 W/HP
109
136
 
110
- OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.FluidCooler', "For #{fluid_cooler.name}, allowed fan motor nameplate hp = #{fan_motor_nameplate_hp.round(1)} hp, fan brake horsepower = #{fan_bhp.round(1)}, and fan motor actual power = #{fan_motor_actual_power_hp.round(1)} hp (#{fan_motor_actual_power_w.round} W) at #{fan_motor_eff} motor efficiency.")
137
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.FluidCooler', "For #{fluid_cooler.name}, allowed fan motor nameplate hp = #{nominal_hp.round(1)} hp, fan brake horsepower = #{fan_bhp.round(1)}, and fan motor actual power = #{fan_motor_actual_power_hp.round(1)} hp (#{fan_motor_actual_power_w.round} W) at #{fan_motor_eff} motor efficiency.")
111
138
 
112
139
  # Append the efficiency to the name
113
140
  fluid_cooler.setName("#{fluid_cooler.name} #{min_gpm_per_hp.to_f.round(1)} gpm/hp")
@@ -8,21 +8,26 @@ class Standard
8
8
  def heat_exchanger_air_to_air_sensible_and_latent_apply_effectiveness(heat_exchanger_air_to_air_sensible_and_latent)
9
9
  # Assumed to be sensible and latent at all flow
10
10
  full_htg_sens_eff, full_htg_lat_eff, part_htg_sens_eff, part_htg_lat_eff, full_cool_sens_eff, full_cool_lat_eff, part_cool_sens_eff, part_cool_lat_eff = heat_exchanger_air_to_air_sensible_and_latent_minimum_effectiveness(heat_exchanger_air_to_air_sensible_and_latent)
11
-
12
- heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat100HeatingAirFlow(full_htg_sens_eff)
13
- heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat100HeatingAirFlow(full_htg_lat_eff)
14
- heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat100CoolingAirFlow(full_cool_sens_eff)
15
- heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat100CoolingAirFlow(full_cool_lat_eff)
16
11
  if heat_exchanger_air_to_air_sensible_and_latent.model.version < OpenStudio::VersionString.new('3.8.0')
12
+ heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat100HeatingAirFlow(full_htg_sens_eff)
13
+ heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat100HeatingAirFlow(full_htg_lat_eff)
14
+ heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat100CoolingAirFlow(full_cool_sens_eff)
15
+ heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat100CoolingAirFlow(full_cool_lat_eff)
17
16
  heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat75HeatingAirFlow(part_htg_sens_eff)
18
17
  heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat75HeatingAirFlow(part_htg_lat_eff)
19
18
  heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat75CoolingAirFlow(part_cool_sens_eff)
20
19
  heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat75CoolingAirFlow(part_cool_lat_eff)
21
20
  else
22
- heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat75HeatingAirFlow(part_htg_sens_eff) unless part_htg_sens_eff.zero?
23
- heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat75HeatingAirFlow(part_htg_lat_eff) unless part_htg_lat_eff.zero?
24
- heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat75CoolingAirFlow(part_cool_sens_eff) unless part_cool_sens_eff.zero?
25
- heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat75CoolingAirFlow(part_cool_lat_eff) unless part_cool_lat_eff.zero?
21
+ values = Hash.new{|hash, key| hash[key] = Hash.new}
22
+ values['Sensible Heating'][0.75] = part_htg_sens_eff
23
+ values['Sensible Heating'][1.0] = full_htg_sens_eff
24
+ values['Latent Heating'][0.75] = part_htg_lat_eff
25
+ values['Latent Heating'][1.0] = full_htg_lat_eff
26
+ values['Sensible Cooling'][0.75] = part_cool_sens_eff
27
+ values['Sensible Cooling'][1.0] = full_cool_sens_eff
28
+ values['Latent Cooling'][0.75] = part_cool_lat_eff
29
+ values['Latent Cooling'][1.0] = full_cool_lat_eff
30
+ OpenstudioStandards::HVAC.heat_exchanger_air_to_air_set_effectiveness_values(heat_exchanger_air_to_air_sensible_and_latent, defaults: false, values: values)
26
31
  end
27
32
 
28
33
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.HeatExchangerSensLat', "For #{heat_exchanger_air_to_air_sensible_and_latent.name}: Set sensible and latent effectiveness.")