openstudio-standards 0.7.1 → 0.8.0.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAE90120162019LargeHotel.json +58 -13
- data/data/geometry/ASHRAELargeHotel.json +58 -13
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/export_OpenStudio_libraries.rb +2 -2
- data/data/standards/manage_OpenStudio_Standards.rb +6 -6
- data/data/standards/openstudio_standards_duplicates_log.csv +7961 -1
- data/data/standards/test_performance_expected_dd_results.csv +2016 -2004
- data/lib/openstudio-standards/btap/fileio.rb +171 -5
- data/lib/openstudio-standards/constructions/create.rb +38 -4
- data/lib/openstudio-standards/constructions/modify.rb +10 -3
- data/lib/openstudio-standards/create_typical/create_typical.rb +42 -28
- data/lib/openstudio-standards/create_typical/space_type_information.rb +160 -0
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +16 -19
- data/lib/openstudio-standards/exterior_lighting/create.rb +454 -0
- data/lib/openstudio-standards/exterior_lighting/data/entryways.csv +52 -0
- data/lib/openstudio-standards/exterior_lighting/data/parking.csv +54 -0
- data/lib/openstudio-standards/exterior_lighting/data/typical_exterior_lighting.json +37 -0
- data/lib/openstudio-standards/exterior_lighting/information.rb +202 -0
- data/lib/openstudio-standards/geometry/information.rb +49 -2
- data/lib/openstudio-standards/hvac/components/create.rb +169 -0
- data/lib/openstudio-standards/hvac/components/modify.rb +42 -0
- data/lib/openstudio-standards/hvac/exhaust/create_exhaust_fan.rb +108 -0
- data/lib/openstudio-standards/hvac/exhaust/data/convert_data.rb +86 -0
- data/lib/openstudio-standards/hvac/exhaust/data/typical_exhaust.csv +18 -0
- data/lib/openstudio-standards/hvac/exhaust/data/typical_exhaust.json +89 -0
- data/lib/openstudio-standards/infiltration/nist_infiltration.rb +25 -13
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +0 -64
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +0 -25
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +0 -25
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +1 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +5 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -7
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +36 -18
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +121 -239
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +179 -151
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +0 -466
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +18 -2
- data/lib/openstudio-standards/refrigeration/create_case.rb +125 -0
- data/lib/openstudio-standards/refrigeration/create_compressor.rb +78 -0
- data/lib/openstudio-standards/refrigeration/create_compressor_rack.rb +48 -0
- data/lib/openstudio-standards/refrigeration/create_refrigeration_system.rb +74 -0
- data/lib/openstudio-standards/refrigeration/create_typical_refrigeration.rb +161 -0
- data/lib/openstudio-standards/refrigeration/create_walkin.rb +116 -0
- data/lib/openstudio-standards/refrigeration/data/refrigerated_cases.csv +31 -0
- data/lib/openstudio-standards/refrigeration/data/refrigerated_walkins.csv +76 -0
- data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +13 -0
- data/lib/openstudio-standards/refrigeration/data/typical_refrigerated_cases.csv +17 -0
- data/lib/openstudio-standards/refrigeration/data/typical_refrigerated_walkins.csv +53 -0
- data/lib/openstudio-standards/refrigeration/information.rb +130 -0
- data/lib/openstudio-standards/schedules/parametric.rb +1 -1
- data/lib/openstudio-standards/service_water_heating/create_typical.rb +299 -0
- data/lib/openstudio-standards/service_water_heating/create_water_heating_loop.rb +16 -14
- data/lib/openstudio-standards/service_water_heating/data/convert_data.rb +119 -0
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.csv +54 -0
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.json +810 -0
- data/lib/openstudio-standards/service_water_heating/information.rb +69 -0
- data/lib/openstudio-standards/sql_file/fenestration.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +154 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +35 -12
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +110 -61
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +128 -29
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +103 -38
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +106 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +8 -8
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +44 -17
- data/lib/openstudio-standards/standards/Standards.Fan.rb +32 -21
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +45 -18
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +14 -9
- data/lib/openstudio-standards/standards/Standards.Model.rb +294 -76
- data/lib/openstudio-standards/standards/Standards.Motor.rb +66 -0
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.Pump.rb +34 -20
- data/lib/openstudio-standards/standards/Standards.ServiceWaterHeating.rb +0 -353
- data/lib/openstudio-standards/standards/Standards.Space.rb +3 -107
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +2 -57
- data/lib/openstudio-standards/standards/Standards.Surface.rb +11 -3
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +1 -120
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.computer_room_acs.json +142 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +1006 -596
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.energy_recovery.json +724 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +1258 -163
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +1070 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +33 -3374
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +1400 -340
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.vrfs.json +769 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +2 -5338
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.computer_room_acs.json +142 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +1006 -596
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.energy_recovery.json +724 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +1258 -163
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +1070 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +15 -3343
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +1840 -372
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.vrfs.json +769 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +20 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +0 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +0 -5382
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.computer_room_acs.json +142 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +1006 -628
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +718 -712
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +1438 -163
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +2552 -182
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +14 -3368
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +2348 -352
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.vrfs.json +769 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +47 -61
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +6 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Motor.rb +11 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +0 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +2 -5522
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.computer_room_acs.json +142 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +1006 -628
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +1358 -1346
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +1438 -163
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +1359 -189
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +19 -3451
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +2176 -616
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.vrfs.json +616 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +47 -61
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Motor.rb +11 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +0 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +8 -6055
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.computer_room_acs.json +142 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.economizers.json +1006 -628
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +1188 -1424
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ext_ltg.json +1498 -163
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.motors.json +1769 -189
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +15 -3422
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +1807 -408
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.vrfs.json +1024 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +70 -87
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Motor.rb +11 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +0 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +8 -6080
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.computer_room_acs.json +142 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.economizers.json +1006 -628
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2806 -3296
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ext_ltg.json +1558 -163
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.motors.json +1759 -189
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +16 -3448
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +2758 -422
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.vrfs.json +684 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +14 -3318
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +2 -4786
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.chillers.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +953 -207
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.energy_recovery.json +724 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +11 -2858
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirConditionerVariableRefrigerantFlow.rb +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +0 -18
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +1 -4739
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.chillers.json +0 -51
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +953 -207
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.energy_recovery.json +724 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +9 -2830
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirConditionerVariableRefrigerantFlow.rb +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +0 -18
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.economizers.json +1006 -564
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.energy_recovery.json +1264 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.spc_typ.json +0 -1079
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +132 -288
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +44 -20
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +11 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.economizers.json +1006 -564
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.energy_recovery.json +1264 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json +0 -1079
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +137 -288
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +44 -20
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +11 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +0 -9
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +12 -10
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +8 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +8 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +9 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Fan.rb +6 -40
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +30 -337
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +4 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +56 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +80 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +0 -10
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +35 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.economizers.json +550 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.energy_recovery.json +724 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.ext_ltg.json +1216 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.motors.json +225 -245
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.unitary_acs.json +174 -78
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.water_heaters.json +354 -317
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +19 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_airloop_hvac.json +185 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_airloop_hvac_doas.json +127 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_building.json +121 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_design_specification_outdoor_air.json +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_electric_equipment.json +113 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_exterior_lights.json +120 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_space.json +388 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_spacetype.json +367 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_thermal_zone.json +56 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_wateruse_connections.json +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_wateruse_equipment.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_json/userdata_wateruse_equipment_definition.json +37 -0
- data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/data/cbes_pre_1978.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/data/cbes_t24_1978.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/data/cbes_t24_1992.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/data/cbes_t24_2001.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/data/cbes_t24_2005.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/data/cbes_t24_2008.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/data/comstock_deer_2020.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/data/comstock_deer_2025.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/data/comstock_deer_2030.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/data/comstock_deer_2035.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/data/comstock_deer_2040.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/data/comstock_deer_2045.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/data/comstock_deer_2050.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/data/comstock_deer_2055.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/data/comstock_deer_2060.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/data/comstock_deer_2065.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/data/comstock_deer_2070.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/data/comstock_deer_2075.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.ext_ltg.json +5 -5
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +10 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/unitary_acs.json +20 -20
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +379 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +1 -4
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +0 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/unitary_acs.json +20 -20
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +34 -22
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +76 -23
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_shw_calculation.xlsx +0 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +6 -2
- data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +26 -24
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +2 -1
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +38 -32
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +215 -18
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +190 -15
- data/lib/openstudio-standards/standards/necb/common/national_carbon_price_sched_feb_2025.json +60 -0
- data/lib/openstudio-standards/standards/necb/common/utility_pricing_2025-02-20.csv +92 -0
- data/lib/openstudio-standards/utilities/ruleset_check.rb +204 -0
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/information.rb +1 -1
- data/lib/openstudio-standards.rb +32 -12
- metadata +78 -80
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +0 -13
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +0 -13
- data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +0 -13
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +0 -432
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +0 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +0 -169
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +0 -20804
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +0 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +0 -169
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +0 -169
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +0 -169
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +0 -169
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ref_cases.json +0 -763
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +0 -169
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ref_cases.json +0 -763
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +0 -169
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ext_ltg.json +0 -169
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_economizers.json +0 -213
- data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +0 -11
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +0 -11
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +0 -11
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +0 -20
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.ref_lnup.json +0 -562
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.ref_cases.json +0 -1456
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.ref_lnup.json +0 -562
@@ -0,0 +1,810 @@
|
|
1
|
+
{
|
2
|
+
"space_types": [
|
3
|
+
{
|
4
|
+
"space_type": "Break Room",
|
5
|
+
"building_type": "Courthouse",
|
6
|
+
"water_use_equipment": [
|
7
|
+
{
|
8
|
+
"equipment_name": null,
|
9
|
+
"peak_flow_rate": null,
|
10
|
+
"peak_flow_rate_per_area": 0.02,
|
11
|
+
"loop_type": "Shared",
|
12
|
+
"temperature": 140.0,
|
13
|
+
"flow_rate_schedule": "Courthouse BLDG_SWH_SCH",
|
14
|
+
"sensible_fraction": 0.2,
|
15
|
+
"latent_fraction": 0.05
|
16
|
+
}
|
17
|
+
]
|
18
|
+
},
|
19
|
+
{
|
20
|
+
"space_type": "Restroom",
|
21
|
+
"building_type": "Courthouse",
|
22
|
+
"water_use_equipment": [
|
23
|
+
{
|
24
|
+
"equipment_name": null,
|
25
|
+
"peak_flow_rate": null,
|
26
|
+
"peak_flow_rate_per_area": 0.02,
|
27
|
+
"loop_type": "Shared",
|
28
|
+
"temperature": 140.0,
|
29
|
+
"flow_rate_schedule": "Courthouse BLDG_SWH_SCH",
|
30
|
+
"sensible_fraction": 0.2,
|
31
|
+
"latent_fraction": 0.05
|
32
|
+
}
|
33
|
+
]
|
34
|
+
},
|
35
|
+
{
|
36
|
+
"space_type": "Kitchen",
|
37
|
+
"building_type": "FullServiceRestaurant",
|
38
|
+
"water_use_equipment": [
|
39
|
+
{
|
40
|
+
"equipment_name": "Dishwasher Booster",
|
41
|
+
"peak_flow_rate": null,
|
42
|
+
"peak_flow_rate_per_area": 0.054,
|
43
|
+
"loop_type": "Shared",
|
44
|
+
"temperature": 180.0,
|
45
|
+
"flow_rate_schedule": "RestaurantSitDown BLDG_SWH_SCH",
|
46
|
+
"sensible_fraction": 0.2,
|
47
|
+
"latent_fraction": 0.05
|
48
|
+
},
|
49
|
+
{
|
50
|
+
"equipment_name": null,
|
51
|
+
"peak_flow_rate": null,
|
52
|
+
"peak_flow_rate_per_area": 0.036,
|
53
|
+
"loop_type": "Shared",
|
54
|
+
"temperature": 140.0,
|
55
|
+
"flow_rate_schedule": "RestaurantSitDown BLDG_SWH_SCH",
|
56
|
+
"sensible_fraction": 0.2,
|
57
|
+
"latent_fraction": 0.05
|
58
|
+
}
|
59
|
+
]
|
60
|
+
},
|
61
|
+
{
|
62
|
+
"space_type": "Apartment",
|
63
|
+
"building_type": "HighriseApartment",
|
64
|
+
"water_use_equipment": [
|
65
|
+
{
|
66
|
+
"equipment_name": null,
|
67
|
+
"peak_flow_rate": null,
|
68
|
+
"peak_flow_rate_per_area": 0.003663158,
|
69
|
+
"loop_type": "Shared",
|
70
|
+
"temperature": 140.0,
|
71
|
+
"flow_rate_schedule": "ApartmentHighRise APT_DHW_SCH",
|
72
|
+
"sensible_fraction": 0.2,
|
73
|
+
"latent_fraction": 0.05
|
74
|
+
}
|
75
|
+
]
|
76
|
+
},
|
77
|
+
{
|
78
|
+
"space_type": "ER_Exam",
|
79
|
+
"building_type": "Hospital",
|
80
|
+
"water_use_equipment": [
|
81
|
+
{
|
82
|
+
"equipment_name": null,
|
83
|
+
"peak_flow_rate": null,
|
84
|
+
"peak_flow_rate_per_area": 0.003333333,
|
85
|
+
"loop_type": "Shared",
|
86
|
+
"temperature": 140.0,
|
87
|
+
"flow_rate_schedule": "Hospital BLDG_SWH_EXTD_SCH",
|
88
|
+
"sensible_fraction": 0.2,
|
89
|
+
"latent_fraction": 0.05
|
90
|
+
}
|
91
|
+
]
|
92
|
+
},
|
93
|
+
{
|
94
|
+
"space_type": "ER_Trauma",
|
95
|
+
"building_type": "Hospital",
|
96
|
+
"water_use_equipment": [
|
97
|
+
{
|
98
|
+
"equipment_name": null,
|
99
|
+
"peak_flow_rate": null,
|
100
|
+
"peak_flow_rate_per_area": 0.003333333,
|
101
|
+
"loop_type": "Shared",
|
102
|
+
"temperature": 140.0,
|
103
|
+
"flow_rate_schedule": "Hospital BLDG_SWH_EXTD_SCH",
|
104
|
+
"sensible_fraction": 0.2,
|
105
|
+
"latent_fraction": 0.05
|
106
|
+
}
|
107
|
+
]
|
108
|
+
},
|
109
|
+
{
|
110
|
+
"space_type": "ER_Triage",
|
111
|
+
"building_type": "Hospital",
|
112
|
+
"water_use_equipment": [
|
113
|
+
{
|
114
|
+
"equipment_name": null,
|
115
|
+
"peak_flow_rate": null,
|
116
|
+
"peak_flow_rate_per_area": 0.003333333,
|
117
|
+
"loop_type": "Shared",
|
118
|
+
"temperature": 140.0,
|
119
|
+
"flow_rate_schedule": "Hospital BLDG_SWH_EXTD_SCH",
|
120
|
+
"sensible_fraction": 0.2,
|
121
|
+
"latent_fraction": 0.05
|
122
|
+
}
|
123
|
+
]
|
124
|
+
},
|
125
|
+
{
|
126
|
+
"space_type": "Kitchen",
|
127
|
+
"building_type": "Hospital",
|
128
|
+
"water_use_equipment": [
|
129
|
+
{
|
130
|
+
"equipment_name": "Dishwasher Booster",
|
131
|
+
"peak_flow_rate": null,
|
132
|
+
"peak_flow_rate_per_area": 0.009,
|
133
|
+
"loop_type": "Shared",
|
134
|
+
"temperature": 180.0,
|
135
|
+
"flow_rate_schedule": "Hospital BLDG_SWH_EXTD_SCH",
|
136
|
+
"sensible_fraction": 0.2,
|
137
|
+
"latent_fraction": 0.05
|
138
|
+
},
|
139
|
+
{
|
140
|
+
"equipment_name": null,
|
141
|
+
"peak_flow_rate": null,
|
142
|
+
"peak_flow_rate_per_area": 0.006,
|
143
|
+
"loop_type": "Shared",
|
144
|
+
"temperature": 140.0,
|
145
|
+
"flow_rate_schedule": "Hospital BLDG_SWH_EXTD_SCH",
|
146
|
+
"sensible_fraction": 0.2,
|
147
|
+
"latent_fraction": 0.05
|
148
|
+
}
|
149
|
+
]
|
150
|
+
},
|
151
|
+
{
|
152
|
+
"space_type": "Lab",
|
153
|
+
"building_type": "Hospital",
|
154
|
+
"water_use_equipment": [
|
155
|
+
{
|
156
|
+
"equipment_name": null,
|
157
|
+
"peak_flow_rate": null,
|
158
|
+
"peak_flow_rate_per_area": 0.000701754,
|
159
|
+
"loop_type": "Shared",
|
160
|
+
"temperature": 140.0,
|
161
|
+
"flow_rate_schedule": "Hospital BLDG_SWH_SCH",
|
162
|
+
"sensible_fraction": 0.2,
|
163
|
+
"latent_fraction": 0.05
|
164
|
+
}
|
165
|
+
]
|
166
|
+
},
|
167
|
+
{
|
168
|
+
"space_type": "OR",
|
169
|
+
"building_type": "Hospital",
|
170
|
+
"water_use_equipment": [
|
171
|
+
{
|
172
|
+
"equipment_name": null,
|
173
|
+
"peak_flow_rate": null,
|
174
|
+
"peak_flow_rate_per_area": 0.003333333,
|
175
|
+
"loop_type": "Shared",
|
176
|
+
"temperature": 140.0,
|
177
|
+
"flow_rate_schedule": "Hospital BLDG_SWH_SCH",
|
178
|
+
"sensible_fraction": 0.2,
|
179
|
+
"latent_fraction": 0.05
|
180
|
+
}
|
181
|
+
]
|
182
|
+
},
|
183
|
+
{
|
184
|
+
"space_type": "PatRoom",
|
185
|
+
"building_type": "Hospital",
|
186
|
+
"water_use_equipment": [
|
187
|
+
{
|
188
|
+
"equipment_name": null,
|
189
|
+
"peak_flow_rate": null,
|
190
|
+
"peak_flow_rate_per_area": 0.003571429,
|
191
|
+
"loop_type": "Shared",
|
192
|
+
"temperature": 140.0,
|
193
|
+
"flow_rate_schedule": "Hospital BLDG_SWH_EXTD_SCH",
|
194
|
+
"sensible_fraction": 0.2,
|
195
|
+
"latent_fraction": 0.05
|
196
|
+
}
|
197
|
+
]
|
198
|
+
},
|
199
|
+
{
|
200
|
+
"space_type": "PhysTherapy",
|
201
|
+
"building_type": "Hospital",
|
202
|
+
"water_use_equipment": [
|
203
|
+
{
|
204
|
+
"equipment_name": null,
|
205
|
+
"peak_flow_rate": null,
|
206
|
+
"peak_flow_rate_per_area": 0.000189394,
|
207
|
+
"loop_type": "Shared",
|
208
|
+
"temperature": 140.0,
|
209
|
+
"flow_rate_schedule": "Hospital BLDG_SWH_SCH",
|
210
|
+
"sensible_fraction": 0.2,
|
211
|
+
"latent_fraction": 0.05
|
212
|
+
}
|
213
|
+
]
|
214
|
+
},
|
215
|
+
{
|
216
|
+
"space_type": "Radiology",
|
217
|
+
"building_type": "Hospital",
|
218
|
+
"water_use_equipment": [
|
219
|
+
{
|
220
|
+
"equipment_name": null,
|
221
|
+
"peak_flow_rate": null,
|
222
|
+
"peak_flow_rate_per_area": 0.000190476,
|
223
|
+
"loop_type": "Shared",
|
224
|
+
"temperature": 140.0,
|
225
|
+
"flow_rate_schedule": "Hospital BLDG_SWH_EXTD_SCH",
|
226
|
+
"sensible_fraction": 0.2,
|
227
|
+
"latent_fraction": 0.05
|
228
|
+
}
|
229
|
+
]
|
230
|
+
},
|
231
|
+
{
|
232
|
+
"space_type": "GuestRoom",
|
233
|
+
"building_type": "LargeHotel",
|
234
|
+
"water_use_equipment": [
|
235
|
+
{
|
236
|
+
"equipment_name": null,
|
237
|
+
"peak_flow_rate": null,
|
238
|
+
"peak_flow_rate_per_area": 0.00297619,
|
239
|
+
"loop_type": "Shared",
|
240
|
+
"temperature": 140.0,
|
241
|
+
"flow_rate_schedule": "HotelLarge GuestRoom_SWH_Sch",
|
242
|
+
"sensible_fraction": 0.2,
|
243
|
+
"latent_fraction": 0.05
|
244
|
+
}
|
245
|
+
]
|
246
|
+
},
|
247
|
+
{
|
248
|
+
"space_type": "Kitchen",
|
249
|
+
"building_type": "LargeHotel",
|
250
|
+
"water_use_equipment": [
|
251
|
+
{
|
252
|
+
"equipment_name": "Dishwasher Booster",
|
253
|
+
"peak_flow_rate": null,
|
254
|
+
"peak_flow_rate_per_area": 0.072,
|
255
|
+
"loop_type": "Shared",
|
256
|
+
"temperature": 180.0,
|
257
|
+
"flow_rate_schedule": "HotelLarge BLDG_SWH_SCH",
|
258
|
+
"sensible_fraction": 0.2,
|
259
|
+
"latent_fraction": 0.05
|
260
|
+
},
|
261
|
+
{
|
262
|
+
"equipment_name": null,
|
263
|
+
"peak_flow_rate": null,
|
264
|
+
"peak_flow_rate_per_area": 0.048,
|
265
|
+
"loop_type": "Shared",
|
266
|
+
"temperature": 140.0,
|
267
|
+
"flow_rate_schedule": "HotelLarge BLDG_SWH_SCH",
|
268
|
+
"sensible_fraction": 0.2,
|
269
|
+
"latent_fraction": 0.05
|
270
|
+
}
|
271
|
+
]
|
272
|
+
},
|
273
|
+
{
|
274
|
+
"space_type": "Laundry",
|
275
|
+
"building_type": "LargeHotel",
|
276
|
+
"water_use_equipment": [
|
277
|
+
{
|
278
|
+
"equipment_name": null,
|
279
|
+
"peak_flow_rate": null,
|
280
|
+
"peak_flow_rate_per_area": 0.186428571,
|
281
|
+
"loop_type": "Shared",
|
282
|
+
"temperature": 140.0,
|
283
|
+
"flow_rate_schedule": "HotelLarge LaundryRoom_SWH_Sch_Post2004",
|
284
|
+
"sensible_fraction": 0.2,
|
285
|
+
"latent_fraction": 0.05
|
286
|
+
}
|
287
|
+
]
|
288
|
+
},
|
289
|
+
{
|
290
|
+
"space_type": "Apartment",
|
291
|
+
"building_type": "MidriseApartment",
|
292
|
+
"water_use_equipment": [
|
293
|
+
{
|
294
|
+
"equipment_name": null,
|
295
|
+
"peak_flow_rate": 3.48,
|
296
|
+
"peak_flow_rate_per_area": 0.003663158,
|
297
|
+
"loop_type": "One Per Unit",
|
298
|
+
"temperature": 140.0,
|
299
|
+
"flow_rate_schedule": "ApartmentMidRise APT_DHW_SCH",
|
300
|
+
"sensible_fraction": 0.2,
|
301
|
+
"latent_fraction": 0.05
|
302
|
+
}
|
303
|
+
]
|
304
|
+
},
|
305
|
+
{
|
306
|
+
"space_type": "Restroom",
|
307
|
+
"building_type": "Office",
|
308
|
+
"water_use_equipment": [
|
309
|
+
{
|
310
|
+
"equipment_name": null,
|
311
|
+
"peak_flow_rate": null,
|
312
|
+
"peak_flow_rate_per_area": 0.02,
|
313
|
+
"loop_type": "Shared",
|
314
|
+
"temperature": 140.0,
|
315
|
+
"flow_rate_schedule": "OfficeMedium BLDG_SWH_SCH",
|
316
|
+
"sensible_fraction": 0.2,
|
317
|
+
"latent_fraction": 0.05
|
318
|
+
},
|
319
|
+
{
|
320
|
+
"equipment_name": null,
|
321
|
+
"peak_flow_rate": null,
|
322
|
+
"peak_flow_rate_per_area": 0.02,
|
323
|
+
"loop_type": "Shared",
|
324
|
+
"temperature": 140.0,
|
325
|
+
"flow_rate_schedule": "OfficeMedium BLDG_SWH_SCH",
|
326
|
+
"sensible_fraction": 0.2,
|
327
|
+
"latent_fraction": 0.05
|
328
|
+
},
|
329
|
+
{
|
330
|
+
"equipment_name": null,
|
331
|
+
"peak_flow_rate": null,
|
332
|
+
"peak_flow_rate_per_area": 0.02,
|
333
|
+
"loop_type": "Shared",
|
334
|
+
"temperature": 140.0,
|
335
|
+
"flow_rate_schedule": "OfficeSmall BLDG_SWH_SCH",
|
336
|
+
"sensible_fraction": 0.2,
|
337
|
+
"latent_fraction": 0.05
|
338
|
+
}
|
339
|
+
]
|
340
|
+
},
|
341
|
+
{
|
342
|
+
"space_type": "WholeBuilding - Lg Office",
|
343
|
+
"building_type": "Office",
|
344
|
+
"water_use_equipment": [
|
345
|
+
{
|
346
|
+
"equipment_name": null,
|
347
|
+
"peak_flow_rate": null,
|
348
|
+
"peak_flow_rate_per_area": 0.000516521,
|
349
|
+
"loop_type": "Shared",
|
350
|
+
"temperature": 140.0,
|
351
|
+
"flow_rate_schedule": "OfficeLarge BLDG_SWH_SCH",
|
352
|
+
"sensible_fraction": 0.2,
|
353
|
+
"latent_fraction": 0.05
|
354
|
+
}
|
355
|
+
]
|
356
|
+
},
|
357
|
+
{
|
358
|
+
"space_type": "WholeBuilding - Lg Office-basement",
|
359
|
+
"building_type": "Office",
|
360
|
+
"water_use_equipment": [
|
361
|
+
{
|
362
|
+
"equipment_name": null,
|
363
|
+
"peak_flow_rate": null,
|
364
|
+
"peak_flow_rate_per_area": 0.000516521,
|
365
|
+
"loop_type": "Shared",
|
366
|
+
"temperature": 140.0,
|
367
|
+
"flow_rate_schedule": "OfficeLarge BLDG_SWH_SCH",
|
368
|
+
"sensible_fraction": 0.2,
|
369
|
+
"latent_fraction": 0.05
|
370
|
+
}
|
371
|
+
]
|
372
|
+
},
|
373
|
+
{
|
374
|
+
"space_type": "WholeBuilding - Lg Office-others",
|
375
|
+
"building_type": "Office",
|
376
|
+
"water_use_equipment": [
|
377
|
+
{
|
378
|
+
"equipment_name": null,
|
379
|
+
"peak_flow_rate": null,
|
380
|
+
"peak_flow_rate_per_area": 0.000516521,
|
381
|
+
"loop_type": "Shared",
|
382
|
+
"temperature": 140.0,
|
383
|
+
"flow_rate_schedule": "OfficeLarge BLDG_SWH_SCH",
|
384
|
+
"sensible_fraction": 0.2,
|
385
|
+
"latent_fraction": 0.05
|
386
|
+
}
|
387
|
+
]
|
388
|
+
},
|
389
|
+
{
|
390
|
+
"space_type": "WholeBuilding - Md Office",
|
391
|
+
"building_type": "Office",
|
392
|
+
"water_use_equipment": [
|
393
|
+
{
|
394
|
+
"equipment_name": null,
|
395
|
+
"peak_flow_rate": null,
|
396
|
+
"peak_flow_rate_per_area": 0.000950996,
|
397
|
+
"loop_type": "Shared",
|
398
|
+
"temperature": 140.0,
|
399
|
+
"flow_rate_schedule": "OfficeMedium BLDG_SWH_SCH",
|
400
|
+
"sensible_fraction": 0.2,
|
401
|
+
"latent_fraction": 0.05
|
402
|
+
}
|
403
|
+
]
|
404
|
+
},
|
405
|
+
{
|
406
|
+
"space_type": "WholeBuilding - Sm Office",
|
407
|
+
"building_type": "Office",
|
408
|
+
"water_use_equipment": [
|
409
|
+
{
|
410
|
+
"equipment_name": null,
|
411
|
+
"peak_flow_rate": null,
|
412
|
+
"peak_flow_rate_per_area": 0.000545256,
|
413
|
+
"loop_type": "Shared",
|
414
|
+
"temperature": 140.0,
|
415
|
+
"flow_rate_schedule": "OfficeSmall BLDG_SWH_SCH",
|
416
|
+
"sensible_fraction": 0.2,
|
417
|
+
"latent_fraction": 0.05
|
418
|
+
}
|
419
|
+
]
|
420
|
+
},
|
421
|
+
{
|
422
|
+
"space_type": "Anesthesia",
|
423
|
+
"building_type": "Outpatient",
|
424
|
+
"water_use_equipment": [
|
425
|
+
{
|
426
|
+
"equipment_name": null,
|
427
|
+
"peak_flow_rate": null,
|
428
|
+
"peak_flow_rate_per_area": 0.018518519,
|
429
|
+
"loop_type": "Shared",
|
430
|
+
"temperature": 140.0,
|
431
|
+
"flow_rate_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
|
432
|
+
"sensible_fraction": 0.2,
|
433
|
+
"latent_fraction": 0.05
|
434
|
+
}
|
435
|
+
]
|
436
|
+
},
|
437
|
+
{
|
438
|
+
"space_type": "MRI",
|
439
|
+
"building_type": "Outpatient",
|
440
|
+
"water_use_equipment": [
|
441
|
+
{
|
442
|
+
"equipment_name": null,
|
443
|
+
"peak_flow_rate": null,
|
444
|
+
"peak_flow_rate_per_area": 0.004545455,
|
445
|
+
"loop_type": "Shared",
|
446
|
+
"temperature": 140.0,
|
447
|
+
"flow_rate_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
|
448
|
+
"sensible_fraction": 0.2,
|
449
|
+
"latent_fraction": 0.05
|
450
|
+
}
|
451
|
+
]
|
452
|
+
},
|
453
|
+
{
|
454
|
+
"space_type": "MRI_Control",
|
455
|
+
"building_type": "Outpatient",
|
456
|
+
"water_use_equipment": [
|
457
|
+
{
|
458
|
+
"equipment_name": null,
|
459
|
+
"peak_flow_rate": null,
|
460
|
+
"peak_flow_rate_per_area": 0.011904762,
|
461
|
+
"loop_type": "Shared",
|
462
|
+
"temperature": 140.0,
|
463
|
+
"flow_rate_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
|
464
|
+
"sensible_fraction": 0.2,
|
465
|
+
"latent_fraction": 0.05
|
466
|
+
}
|
467
|
+
]
|
468
|
+
},
|
469
|
+
{
|
470
|
+
"space_type": "OR",
|
471
|
+
"building_type": "Outpatient",
|
472
|
+
"water_use_equipment": [
|
473
|
+
{
|
474
|
+
"equipment_name": null,
|
475
|
+
"peak_flow_rate": null,
|
476
|
+
"peak_flow_rate_per_area": 0.025423729,
|
477
|
+
"loop_type": "Shared",
|
478
|
+
"temperature": 140.0,
|
479
|
+
"flow_rate_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
|
480
|
+
"sensible_fraction": 0.2,
|
481
|
+
"latent_fraction": 0.05
|
482
|
+
}
|
483
|
+
]
|
484
|
+
},
|
485
|
+
{
|
486
|
+
"space_type": "PACU",
|
487
|
+
"building_type": "Outpatient",
|
488
|
+
"water_use_equipment": [
|
489
|
+
{
|
490
|
+
"equipment_name": null,
|
491
|
+
"peak_flow_rate": null,
|
492
|
+
"peak_flow_rate_per_area": 0.006329114,
|
493
|
+
"loop_type": "Shared",
|
494
|
+
"temperature": 140.0,
|
495
|
+
"flow_rate_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
|
496
|
+
"sensible_fraction": 0.2,
|
497
|
+
"latent_fraction": 0.05
|
498
|
+
}
|
499
|
+
]
|
500
|
+
},
|
501
|
+
{
|
502
|
+
"space_type": "PhysicalTherapy",
|
503
|
+
"building_type": "Outpatient",
|
504
|
+
"water_use_equipment": [
|
505
|
+
{
|
506
|
+
"equipment_name": null,
|
507
|
+
"peak_flow_rate": null,
|
508
|
+
"peak_flow_rate_per_area": 0.002114165,
|
509
|
+
"loop_type": "Shared",
|
510
|
+
"temperature": 140.0,
|
511
|
+
"flow_rate_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
|
512
|
+
"sensible_fraction": 0.2,
|
513
|
+
"latent_fraction": 0.05
|
514
|
+
}
|
515
|
+
]
|
516
|
+
},
|
517
|
+
{
|
518
|
+
"space_type": "PreOp",
|
519
|
+
"building_type": "Outpatient",
|
520
|
+
"water_use_equipment": [
|
521
|
+
{
|
522
|
+
"equipment_name": null,
|
523
|
+
"peak_flow_rate": null,
|
524
|
+
"peak_flow_rate_per_area": 0.007590133,
|
525
|
+
"loop_type": "Shared",
|
526
|
+
"temperature": 140.0,
|
527
|
+
"flow_rate_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
|
528
|
+
"sensible_fraction": 0.2,
|
529
|
+
"latent_fraction": 0.05
|
530
|
+
}
|
531
|
+
]
|
532
|
+
},
|
533
|
+
{
|
534
|
+
"space_type": "ProcedureRoom",
|
535
|
+
"building_type": "Outpatient",
|
536
|
+
"water_use_equipment": [
|
537
|
+
{
|
538
|
+
"equipment_name": null,
|
539
|
+
"peak_flow_rate": null,
|
540
|
+
"peak_flow_rate_per_area": 0.007017544,
|
541
|
+
"loop_type": "Shared",
|
542
|
+
"temperature": 140.0,
|
543
|
+
"flow_rate_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
|
544
|
+
"sensible_fraction": 0.2,
|
545
|
+
"latent_fraction": 0.05
|
546
|
+
}
|
547
|
+
]
|
548
|
+
},
|
549
|
+
{
|
550
|
+
"space_type": "Xray",
|
551
|
+
"building_type": "Outpatient",
|
552
|
+
"water_use_equipment": [
|
553
|
+
{
|
554
|
+
"equipment_name": null,
|
555
|
+
"peak_flow_rate": null,
|
556
|
+
"peak_flow_rate_per_area": 0.002222222,
|
557
|
+
"loop_type": "Shared",
|
558
|
+
"temperature": 140.0,
|
559
|
+
"flow_rate_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
|
560
|
+
"sensible_fraction": 0.2,
|
561
|
+
"latent_fraction": 0.05
|
562
|
+
}
|
563
|
+
]
|
564
|
+
},
|
565
|
+
{
|
566
|
+
"space_type": "Restroom",
|
567
|
+
"building_type": "PrimarySchool",
|
568
|
+
"water_use_equipment": [
|
569
|
+
{
|
570
|
+
"equipment_name": null,
|
571
|
+
"peak_flow_rate": null,
|
572
|
+
"peak_flow_rate_per_area": 0.02,
|
573
|
+
"loop_type": "Shared",
|
574
|
+
"temperature": 140.0,
|
575
|
+
"flow_rate_schedule": "SchoolPrimary BLDG_SWH_SCH",
|
576
|
+
"sensible_fraction": 0.2,
|
577
|
+
"latent_fraction": 0.05
|
578
|
+
}
|
579
|
+
]
|
580
|
+
},
|
581
|
+
{
|
582
|
+
"space_type": "Kitchen",
|
583
|
+
"building_type": "SecondarySchool",
|
584
|
+
"water_use_equipment": [
|
585
|
+
{
|
586
|
+
"equipment_name": "Dishwasher Booster",
|
587
|
+
"peak_flow_rate": null,
|
588
|
+
"peak_flow_rate_per_area": 0.034,
|
589
|
+
"loop_type": "Shared",
|
590
|
+
"temperature": 180.0,
|
591
|
+
"flow_rate_schedule": "SchoolSecondary BLDG_SWH_SCH",
|
592
|
+
"sensible_fraction": 0.2,
|
593
|
+
"latent_fraction": 0.05
|
594
|
+
},
|
595
|
+
{
|
596
|
+
"equipment_name": null,
|
597
|
+
"peak_flow_rate": null,
|
598
|
+
"peak_flow_rate_per_area": 0.023,
|
599
|
+
"loop_type": "Shared",
|
600
|
+
"temperature": 140.0,
|
601
|
+
"flow_rate_schedule": "SchoolSecondary BLDG_SWH_SCH",
|
602
|
+
"sensible_fraction": 0.2,
|
603
|
+
"latent_fraction": 0.05
|
604
|
+
}
|
605
|
+
]
|
606
|
+
},
|
607
|
+
{
|
608
|
+
"space_type": "Kitchen",
|
609
|
+
"building_type": "PrimarySchool",
|
610
|
+
"water_use_equipment": [
|
611
|
+
{
|
612
|
+
"equipment_name": "Dishwasher Booster",
|
613
|
+
"peak_flow_rate": null,
|
614
|
+
"peak_flow_rate_per_area": 0.033,
|
615
|
+
"loop_type": "Shared",
|
616
|
+
"temperature": 180.0,
|
617
|
+
"flow_rate_schedule": "SchoolPrimary BLDG_SWH_SCH",
|
618
|
+
"sensible_fraction": 0.2,
|
619
|
+
"latent_fraction": 0.05
|
620
|
+
},
|
621
|
+
{
|
622
|
+
"equipment_name": null,
|
623
|
+
"peak_flow_rate": null,
|
624
|
+
"peak_flow_rate_per_area": 0.022,
|
625
|
+
"loop_type": "Shared",
|
626
|
+
"temperature": 140.0,
|
627
|
+
"flow_rate_schedule": "SchoolPrimary BLDG_SWH_SCH",
|
628
|
+
"sensible_fraction": 0.2,
|
629
|
+
"latent_fraction": 0.05
|
630
|
+
}
|
631
|
+
]
|
632
|
+
},
|
633
|
+
{
|
634
|
+
"space_type": "Kitchen",
|
635
|
+
"building_type": "QuickServiceRestaurant",
|
636
|
+
"water_use_equipment": [
|
637
|
+
{
|
638
|
+
"equipment_name": null,
|
639
|
+
"peak_flow_rate": null,
|
640
|
+
"peak_flow_rate_per_area": 0.032,
|
641
|
+
"loop_type": "Shared",
|
642
|
+
"temperature": 140.0,
|
643
|
+
"flow_rate_schedule": "RestaurantFastFood BLDG_SWH_SCH",
|
644
|
+
"sensible_fraction": 0.2,
|
645
|
+
"latent_fraction": 0.05
|
646
|
+
}
|
647
|
+
]
|
648
|
+
},
|
649
|
+
{
|
650
|
+
"space_type": "Gym",
|
651
|
+
"building_type": "SecondarySchool",
|
652
|
+
"water_use_equipment": [
|
653
|
+
{
|
654
|
+
"equipment_name": null,
|
655
|
+
"peak_flow_rate": null,
|
656
|
+
"peak_flow_rate_per_area": 0.007499177,
|
657
|
+
"loop_type": "Shared",
|
658
|
+
"temperature": 140.0,
|
659
|
+
"flow_rate_schedule": "SchoolSecondary BLDG_SWH_SCH",
|
660
|
+
"sensible_fraction": 0.2,
|
661
|
+
"latent_fraction": 0.05
|
662
|
+
}
|
663
|
+
]
|
664
|
+
},
|
665
|
+
{
|
666
|
+
"space_type": "Restroom",
|
667
|
+
"building_type": "SecondarySchool",
|
668
|
+
"water_use_equipment": [
|
669
|
+
{
|
670
|
+
"equipment_name": null,
|
671
|
+
"peak_flow_rate": null,
|
672
|
+
"peak_flow_rate_per_area": 0.02,
|
673
|
+
"loop_type": "Shared",
|
674
|
+
"temperature": 140.0,
|
675
|
+
"flow_rate_schedule": "SchoolSecondary BLDG_SWH_SCH",
|
676
|
+
"sensible_fraction": 0.2,
|
677
|
+
"latent_fraction": 0.05
|
678
|
+
}
|
679
|
+
]
|
680
|
+
},
|
681
|
+
{
|
682
|
+
"space_type": "GuestRoom123Occ",
|
683
|
+
"building_type": "SmallHotel",
|
684
|
+
"water_use_equipment": [
|
685
|
+
{
|
686
|
+
"equipment_name": null,
|
687
|
+
"peak_flow_rate": null,
|
688
|
+
"peak_flow_rate_per_area": 0.006324786,
|
689
|
+
"loop_type": "Shared",
|
690
|
+
"temperature": 140.0,
|
691
|
+
"flow_rate_schedule": "HotelSmall GuestRoom_SHW_Sch",
|
692
|
+
"sensible_fraction": 0.2,
|
693
|
+
"latent_fraction": 0.05
|
694
|
+
}
|
695
|
+
]
|
696
|
+
},
|
697
|
+
{
|
698
|
+
"space_type": "GuestRoom123Vac",
|
699
|
+
"building_type": "SmallHotel",
|
700
|
+
"water_use_equipment": [
|
701
|
+
{
|
702
|
+
"equipment_name": null,
|
703
|
+
"peak_flow_rate": null,
|
704
|
+
"peak_flow_rate_per_area": 0.006324786,
|
705
|
+
"loop_type": "Shared",
|
706
|
+
"temperature": 140.0,
|
707
|
+
"flow_rate_schedule": "HotelSmall AlwaysOff",
|
708
|
+
"sensible_fraction": 0.2,
|
709
|
+
"latent_fraction": 0.05
|
710
|
+
}
|
711
|
+
]
|
712
|
+
},
|
713
|
+
{
|
714
|
+
"space_type": "Laundry",
|
715
|
+
"building_type": "SmallHotel",
|
716
|
+
"water_use_equipment": [
|
717
|
+
{
|
718
|
+
"equipment_name": null,
|
719
|
+
"peak_flow_rate": null,
|
720
|
+
"peak_flow_rate_per_area": 0.064102564,
|
721
|
+
"loop_type": "One Per Space",
|
722
|
+
"temperature": 140.0,
|
723
|
+
"flow_rate_schedule": "HotelSmall LaundryRoom_SHW_Sch",
|
724
|
+
"sensible_fraction": 0.2,
|
725
|
+
"latent_fraction": 0.05
|
726
|
+
}
|
727
|
+
]
|
728
|
+
},
|
729
|
+
{
|
730
|
+
"space_type": "Strip mall - type 1",
|
731
|
+
"building_type": "StripMall",
|
732
|
+
"water_use_equipment": [
|
733
|
+
{
|
734
|
+
"equipment_name": null,
|
735
|
+
"peak_flow_rate": 1.8,
|
736
|
+
"peak_flow_rate_per_area": null,
|
737
|
+
"loop_type": "One Per Space",
|
738
|
+
"temperature": 140.0,
|
739
|
+
"flow_rate_schedule": "RetailStripmall Type1_SWH_SCH",
|
740
|
+
"sensible_fraction": 0.2,
|
741
|
+
"latent_fraction": 0.05
|
742
|
+
}
|
743
|
+
]
|
744
|
+
},
|
745
|
+
{
|
746
|
+
"space_type": "Strip mall - type 2",
|
747
|
+
"building_type": "StripMall",
|
748
|
+
"water_use_equipment": [
|
749
|
+
{
|
750
|
+
"equipment_name": null,
|
751
|
+
"peak_flow_rate": 1.8,
|
752
|
+
"peak_flow_rate_per_area": null,
|
753
|
+
"loop_type": "One Per Space",
|
754
|
+
"temperature": 140.0,
|
755
|
+
"flow_rate_schedule": "RetailStripmall Type2_SWH_SCH",
|
756
|
+
"sensible_fraction": 0.2,
|
757
|
+
"latent_fraction": 0.05
|
758
|
+
}
|
759
|
+
]
|
760
|
+
},
|
761
|
+
{
|
762
|
+
"space_type": "Strip mall - type 3",
|
763
|
+
"building_type": "StripMall",
|
764
|
+
"water_use_equipment": [
|
765
|
+
{
|
766
|
+
"equipment_name": null,
|
767
|
+
"peak_flow_rate": 1.8,
|
768
|
+
"peak_flow_rate_per_area": null,
|
769
|
+
"loop_type": "One Per Space",
|
770
|
+
"temperature": 140.0,
|
771
|
+
"flow_rate_schedule": "RetailStripmall Type3_SWH_SCH",
|
772
|
+
"sensible_fraction": 0.2,
|
773
|
+
"latent_fraction": 0.05
|
774
|
+
}
|
775
|
+
]
|
776
|
+
},
|
777
|
+
{
|
778
|
+
"space_type": "Bakery",
|
779
|
+
"building_type": "SuperMarket",
|
780
|
+
"water_use_equipment": [
|
781
|
+
{
|
782
|
+
"equipment_name": null,
|
783
|
+
"peak_flow_rate": null,
|
784
|
+
"peak_flow_rate_per_area": 0.002141786,
|
785
|
+
"loop_type": "Shared",
|
786
|
+
"temperature": 140.0,
|
787
|
+
"flow_rate_schedule": "SuperMarket Bldg Swh",
|
788
|
+
"sensible_fraction": 0.2,
|
789
|
+
"latent_fraction": 0.05
|
790
|
+
}
|
791
|
+
]
|
792
|
+
},
|
793
|
+
{
|
794
|
+
"space_type": "Deli",
|
795
|
+
"building_type": "SuperMarket",
|
796
|
+
"water_use_equipment": [
|
797
|
+
{
|
798
|
+
"equipment_name": null,
|
799
|
+
"peak_flow_rate": null,
|
800
|
+
"peak_flow_rate_per_area": 0.002141786,
|
801
|
+
"loop_type": "Shared",
|
802
|
+
"temperature": 140.0,
|
803
|
+
"flow_rate_schedule": "SuperMarket Bldg Swh",
|
804
|
+
"sensible_fraction": 0.2,
|
805
|
+
"latent_fraction": 0.05
|
806
|
+
}
|
807
|
+
]
|
808
|
+
}
|
809
|
+
]
|
810
|
+
}
|