openstudio-standards 0.3.0 → 0.3.1.rc1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAESuperMarket.json +29 -38
- data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/metadata_units_OpenStudio_Standards-deer-ALL-comstockspace_types.csv +172 -0
- data/data/standards/test_performance_expected_dd_results.csv +12 -12
- data/lib/openstudio-standards/btap/analysis.rb +389 -389
- data/lib/openstudio-standards/btap/bridging.rb +2099 -0
- data/lib/openstudio-standards/btap/btap.model.rb +717 -717
- data/lib/openstudio-standards/btap/btap.rb +33 -30
- data/lib/openstudio-standards/btap/economics.rb +1163 -1163
- data/lib/openstudio-standards/btap/envelope.rb +4 -4
- data/lib/openstudio-standards/btap/equest.rb +2524 -2524
- data/lib/openstudio-standards/btap/fileio.rb +9 -0
- data/lib/openstudio-standards/btap/measures.rb +1515 -1515
- data/lib/openstudio-standards/btap/mpc.rb +554 -554
- data/lib/openstudio-standards/btap/reporting.rb +287 -287
- data/lib/openstudio-standards/btap/simmanager.rb +759 -759
- data/lib/openstudio-standards/btap/spaceloads.rb +439 -439
- data/lib/openstudio-standards/btap/spacetypes.rb +113 -113
- data/lib/openstudio-standards/btap/utilities.rb +134 -134
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +8 -83
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb +3 -99
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +81 -75
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +7 -306
- data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +70 -98
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +41 -14
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +40 -14
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +1 -23
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +93 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +13 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +24 -4
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +18 -2
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +18 -0
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +13 -10
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +5 -3
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +11 -8
- data/lib/openstudio-standards/standards/Standards.Construction.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Model.rb +68 -52
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.Space.rb +16 -18
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +510 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +18 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +410 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +510 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +18 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +410 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +510 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +18 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +410 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +510 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +18 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +410 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +4 -3
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.ThermalZone.rb +21 -0
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.ThermalZone.rb +21 -0
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.ThermalZone.rb +21 -0
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.ThermalZone.rb +21 -0
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.ThermalZone.rb +21 -0
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.ThermalZone.rb +21 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/data/comstock_deer_2020.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +8 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.ThermalZone.rb +21 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/data/comstock_deer_2025.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/data/comstock_deer_2030.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/data/comstock_deer_2035.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/data/comstock_deer_2040.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/data/comstock_deer_2045.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/data/comstock_deer_2050.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/data/comstock_deer_2055.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/data/comstock_deer_2060.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/data/comstock_deer_2065.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/data/comstock_deer_2070.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/data/comstock_deer_2075.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.spc_typ.json +405 -405
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +1 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +3 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +3 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +2 -2
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +233 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/unitary_acs.json +180 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +6 -1
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +807 -258
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +102 -66
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +85 -8
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartment.osm +2483 -992
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +4 -336
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/MidriseApartment.osm +228 -231
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +12 -18
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_type_unit_definitions.txt +76 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +6 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +111 -24
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +1 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +3 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +64 -16
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +61 -17
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +128 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +252 -23
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +316 -20
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +3 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +38 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +16 -24
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +48 -25
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +36 -19
- data/lib/openstudio-standards/standards/necb/NECB2020/data/furnaces.json +19 -4
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +20 -40
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +74 -36
- data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +0 -2
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +123 -56
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +124 -2
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +15 -2
- data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +1 -1
- data/lib/openstudio-standards/utilities/simulation.rb +1 -1
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +33 -1
- data/lib/openstudio-standards.rb +1 -0
- metadata +14 -121
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/weather/CAN_ON_Kingston.AP.718200_TMYx.2004-2018.ddy +0 -2342
- data/data/weather/CAN_ON_Kingston.AP.718200_TMYx.2004-2018.epw +0 -8768
- data/data/weather/CAN_ON_Kingston.AP.718200_TMYx.2004-2018.stat +0 -700
- data/data/weather/CAN_ON_Region.of.Waterloo.Intl.AP.713680_TMYx.2004-2018.ddy +0 -2342
- data/data/weather/CAN_ON_Region.of.Waterloo.Intl.AP.713680_TMYx.2004-2018.epw +0 -8768
- data/data/weather/CAN_ON_Region.of.Waterloo.Intl.AP.713680_TMYx.2004-2018.stat +0 -700
- data/data/weather/CAN_ON_Sarnia-Hadfield.AP.717040_TMYx.2004-2018.ddy +0 -2342
- data/data/weather/CAN_ON_Sarnia-Hadfield.AP.717040_TMYx.2004-2018.epw +0 -8768
- data/data/weather/CAN_ON_Sarnia-Hadfield.AP.717040_TMYx.2004-2018.stat +0 -700
- data/data/weather/CAN_QC_Gatineau.AP.716279_TMYx.2004-2018.ddy +0 -276
- data/data/weather/CAN_QC_Gatineau.AP.716279_TMYx.2004-2018.epw +0 -8768
- data/data/weather/CAN_QC_Gatineau.AP.716279_TMYx.2004-2018.stat +0 -611
- data/data/weather/CAN_QC_Granby.710367_TMYx.2004-2018.ddy +0 -276
- data/data/weather/CAN_QC_Granby.710367_TMYx.2004-2018.epw +0 -8768
- data/data/weather/CAN_QC_Granby.710367_TMYx.2004-2018.stat +0 -610
- data/data/weather/CAN_QC_Sherbrooke.AP.716100_TMYx.2004-2018.ddy +0 -2342
- data/data/weather/CAN_QC_Sherbrooke.AP.716100_TMYx.2004-2018.epw +0 -8768
- data/data/weather/CAN_QC_Sherbrooke.AP.716100_TMYx.2004-2018.stat +0 -700
- data/data/weather/CAN_QC_Trois.Rivieres.717240_TMYx.2004-2018.ddy +0 -2342
- data/data/weather/CAN_QC_Trois.Rivieres.717240_TMYx.2004-2018.epw +0 -8768
- data/data/weather/CAN_QC_Trois.Rivieres.717240_TMYx.2004-2018.stat +0 -700
- data/lib/openstudio-standards/hvac_sizing/Siz.AirConditionerVariableRefrigerantFlow.rb +0 -81
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVACUnitaryHeatCoolVAVChngByp.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVACUnitaryHeatPumpAirToAir.rb +0 -69
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed.rb +0 -178
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVACUnitarySystem.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.AirTermSnglDuctConstVolCooledBeam.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.AirTermSnglDuctConstVolFourPipeInduction.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.AirTermSnglDuctConstVolReheat.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.AirTermSnglDuctParallelPIUReheat.rb +0 -67
- data/lib/openstudio-standards/hvac_sizing/Siz.AirTermSnglDuctSeriesPIUReheat.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.AirTermSnglDuctUncontrolled.rb +0 -30
- data/lib/openstudio-standards/hvac_sizing/Siz.AirTermSnglDuctVAVHeatAndCoolNoReheat.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.AirTermSnglDuctVAVHeatAndCoolReheat.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.AirTermSnglDuctVAVNoReheat.rb +0 -68
- data/lib/openstudio-standards/hvac_sizing/Siz.AirTermSnglDuctVAVReheat.rb +0 -68
- data/lib/openstudio-standards/hvac_sizing/Siz.BoilerHotWater.rb +0 -42
- data/lib/openstudio-standards/hvac_sizing/Siz.BoilerSteam.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.ChillerElectricEIR.rb +0 -58
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingDXMultiSpeed.rb +0 -171
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingDXSingleSpeed.rb +0 -56
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingDXTwoSpeed.rb +0 -89
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingDXVariableRefrigerantFlow.rb +0 -50
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -69
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingDXMultiSpeed.rb +0 -120
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingDXSingleSpeed.rb +0 -56
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingDXVariableRefrigerantFlow.rb +0 -41
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingDesuperheater.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingElectric.rb +0 -30
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingGas.rb +0 -30
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingGasMultiStage.rb +0 -68
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingWater.rb +0 -61
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -57
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilWaterHeatingDesuperheater.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.ControllerOutdoorAir.rb +0 -59
- data/lib/openstudio-standards/hvac_sizing/Siz.ControllerWaterCoil.rb +0 -49
- data/lib/openstudio-standards/hvac_sizing/Siz.CoolingTowerSingleSpeed.rb +0 -90
- data/lib/openstudio-standards/hvac_sizing/Siz.CoolingTowerTwoSpeed.rb +0 -83
- data/lib/openstudio-standards/hvac_sizing/Siz.CoolingTowerVariableSpeed.rb +0 -57
- data/lib/openstudio-standards/hvac_sizing/Siz.DistrictCooling.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.DistrictHeating.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.EvaporativeCoolerDirectResearchSpecial.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.EvaporativeCoolerIndirectResearchSpecial.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.EvaporativeFluidCoolerSingleSpeed.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.FanConstantVolume.rb +0 -29
- data/lib/openstudio-standards/hvac_sizing/Siz.FanOnOff.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.FanVariableVolume.rb +0 -29
- data/lib/openstudio-standards/hvac_sizing/Siz.HeaderedPumpsConstantSpeed.rb +0 -55
- data/lib/openstudio-standards/hvac_sizing/Siz.HeaderedPumpsVariableSpeed.rb +0 -55
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatExchangerAirToAirSensibleAndLatent.rb +0 -38
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatExchangerFluidToFluid.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.HumidifierSteamElectric.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.PlantLoop.rb +0 -42
- data/lib/openstudio-standards/hvac_sizing/Siz.PumpConstantSpeed.rb +0 -59
- data/lib/openstudio-standards/hvac_sizing/Siz.PumpVariableSpeed.rb +0 -59
- data/lib/openstudio-standards/hvac_sizing/Siz.SizingSystem.rb +0 -48
- data/lib/openstudio-standards/hvac_sizing/Siz.WaterHeaterMixed.rb +0 -16
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACBaseboardConvectiveElectric.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACBaseboardConvectiveWater.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACFourPipeFanCoil.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACHighTemperatureRadiant.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACIdealLoadsAirSystem.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACLowTempRadiantConstFlow.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACLowTempRadiantVarFlow.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACLowTemperatureRadiantElectric.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACPackagedTerminalAirConditioner.rb +0 -88
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACPackagedTerminalHeatPump.rb +0 -88
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +0 -104
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACUnitHeater.rb +0 -27
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACWaterToAirHeatPump.rb +0 -27
@@ -2,323 +2,24 @@
|
|
2
2
|
# open the class to add methods to size all HVAC equipment
|
3
3
|
class OpenStudio::Model::Model
|
4
4
|
|
5
|
-
# Ensure that the version of OpenStudio is
|
6
|
-
# because the
|
7
|
-
|
8
|
-
min_os_version = "1.6.0"
|
5
|
+
# Ensure that the version of OpenStudio is 2.4.1 or greater
|
6
|
+
# because this is when the .autosizedFoo methods were added to C++.
|
7
|
+
min_os_version = "2.4.1"
|
9
8
|
if OpenStudio::Model::Model.new.version < OpenStudio::VersionString.new(min_os_version)
|
10
|
-
OpenStudio::logFree(OpenStudio::Error, "openstudio.model.Model", "This measure requires a minimum OpenStudio version of #{min_os_version} because the
|
9
|
+
OpenStudio::logFree(OpenStudio::Error, "openstudio.model.Model", "This measure requires a minimum OpenStudio version of #{min_os_version} because this is when the .autosizedFoo methods were added to C++.")
|
11
10
|
end
|
12
11
|
|
13
|
-
# Load the helper libraries for getting
|
14
|
-
# values
|
15
|
-
require_relative 'Siz.AirTermSnglDuctParallelPIUReheat'
|
16
|
-
require_relative 'Siz.AirTermSnglDuctVAVReheat'
|
17
|
-
require_relative 'Siz.AirTermSnglDuctUncontrolled'
|
12
|
+
# Load the helper libraries for getting additional autosized
|
13
|
+
# values that aren't included in the C++ API.
|
18
14
|
require_relative 'Siz.AirLoopHVAC'
|
19
|
-
require_relative 'Siz.AirLoopHVACUnitaryHeatPumpAirToAir'
|
20
|
-
require_relative 'Siz.AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed'
|
21
|
-
require_relative 'Siz.FanConstantVolume'
|
22
|
-
require_relative 'Siz.FanVariableVolume'
|
23
|
-
require_relative 'Siz.FanOnOff'
|
24
|
-
require_relative 'Siz.CoilHeatingElectric'
|
25
|
-
require_relative 'Siz.CoilHeatingGas'
|
26
|
-
require_relative 'Siz.CoilHeatingGasMultiStage'
|
27
|
-
require_relative 'Siz.CoilHeatingWater'
|
28
|
-
require_relative 'Siz.CoilHeatingDXSingleSpeed'
|
29
|
-
require_relative 'Siz.CoilHeatingDXMultiSpeed'
|
30
|
-
require_relative 'Siz.CoilHeatingWaterToAirHeatPumpEquationFit'
|
31
|
-
require_relative 'Siz.CoilCoolingWaterToAirHeatPumpEquationFit'
|
32
|
-
require_relative 'Siz.CoilCoolingDXMultiSpeed'
|
33
|
-
require_relative 'Siz.CoilCoolingDXSingleSpeed'
|
34
|
-
require_relative 'Siz.CoilCoolingDXTwoSpeed'
|
35
15
|
require_relative 'Siz.CoilCoolingWater'
|
36
|
-
require_relative 'Siz.ControllerOutdoorAir'
|
37
|
-
require_relative 'Siz.DistrictHeating'
|
38
|
-
require_relative 'Siz.DistrictCooling'
|
39
|
-
require_relative 'Siz.HeatExchangerAirToAirSensibleAndLatent'
|
40
|
-
require_relative 'Siz.PlantLoop'
|
41
|
-
require_relative 'Siz.PumpConstantSpeed'
|
42
|
-
require_relative 'Siz.PumpVariableSpeed'
|
43
|
-
require_relative 'Siz.BoilerHotWater'
|
44
|
-
require_relative 'Siz.ChillerElectricEIR'
|
45
|
-
require_relative 'Siz.CoolingTowerSingleSpeed'
|
46
|
-
require_relative 'Siz.CoolingTowerTwoSpeed'
|
47
|
-
require_relative 'Siz.CoolingTowerVariableSpeed'
|
48
|
-
require_relative 'Siz.ControllerWaterCoil'
|
49
|
-
require_relative 'Siz.SizingSystem'
|
50
16
|
require_relative 'Siz.ThermalZone'
|
51
|
-
require_relative 'Siz.ZoneHVACPackagedTerminalAirConditioner'
|
52
|
-
require_relative 'Siz.ZoneHVACPackagedTerminalHeatPump'
|
53
|
-
require_relative 'Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow'
|
54
|
-
require_relative 'Siz.AirConditionerVariableRefrigerantFlow'
|
55
|
-
require_relative 'Siz.CoilCoolingDXVariableRefrigerantFlow'
|
56
|
-
require_relative 'Siz.CoilHeatingDXVariableRefrigerantFlow'
|
57
|
-
require_relative 'Siz.HeaderedPumpsConstantSpeed'
|
58
|
-
require_relative 'Siz.HeaderedPumpsVariableSpeed'
|
59
17
|
|
60
18
|
# Heating and cooling fuel methods
|
61
19
|
require_relative 'Siz.HeatingCoolingFuels'
|
62
|
-
|
20
|
+
|
63
21
|
# Component quantity methods
|
64
22
|
require_relative 'Siz.HVACComponent'
|
65
|
-
|
66
|
-
# Takes the values calculated by the EnergyPlus sizing routines
|
67
|
-
# and puts them into all objects model in place of the autosized fields.
|
68
|
-
# Must have previously completed a run with sql output for this to work.
|
69
|
-
def applySizingValues
|
70
|
-
|
71
|
-
# Ensure that the model has a sql file associated with it
|
72
|
-
if self.sqlFile.empty?
|
73
|
-
OpenStudio::logFree(OpenStudio::Error, 'openstudio.model.Model', 'Failed to apply sizing values because model is missing sql file containing sizing results.')
|
74
|
-
return false
|
75
|
-
end
|
76
|
-
|
77
|
-
# @todo Sizing methods for these types of equipment are
|
78
|
-
# currently only stubs that need to be filled in.
|
79
|
-
self.getAirConditionerVariableRefrigerantFlows.sort.each {|obj| obj.applySizingValues}
|
80
|
-
self.getAirLoopHVACUnitaryHeatCoolVAVChangeoverBypasss.sort.each {|obj| obj.applySizingValues}
|
81
|
-
self.getAirLoopHVACUnitarySystems.sort.each {|obj| obj.applySizingValues}
|
82
|
-
self.getAirTerminalSingleDuctConstantVolumeCooledBeams.sort.each {|obj| obj.applySizingValues}
|
83
|
-
self.getAirTerminalSingleDuctConstantVolumeFourPipeInductions.sort.each {|obj| obj.applySizingValues}
|
84
|
-
self.getAirTerminalSingleDuctConstantVolumeReheats.sort.each {|obj| obj.applySizingValues}
|
85
|
-
self.getAirTerminalSingleDuctSeriesPIUReheats.sort.each {|obj| obj.applySizingValues}
|
86
|
-
self.getAirTerminalSingleDuctVAVHeatAndCoolNoReheats.sort.each {|obj| obj.applySizingValues}
|
87
|
-
self.getAirTerminalSingleDuctVAVHeatAndCoolReheats.sort.each {|obj| obj.applySizingValues}
|
88
|
-
self.getBoilerSteams.sort.each {|obj| obj.applySizingValues}
|
89
|
-
self.getCoilCoolingDXVariableRefrigerantFlows.sort.each {|obj| obj.applySizingValues}
|
90
|
-
self.getCoilCoolingWaterToAirHeatPumpEquationFits.sort.each {|obj| obj.applySizingValues}
|
91
|
-
self.getCoilHeatingWaterToAirHeatPumpEquationFits.sort.each {|obj| obj.applySizingValues}
|
92
|
-
self.getCoilHeatingDesuperheaters.sort.each {|obj| obj.applySizingValues}
|
93
|
-
self.getCoilHeatingDXVariableRefrigerantFlows.sort.each {|obj| obj.applySizingValues}
|
94
|
-
self.getCoilWaterHeatingDesuperheaters.sort.each {|obj| obj.applySizingValues}
|
95
|
-
self.getCoolingTowerTwoSpeeds.sort.each {|obj| obj.applySizingValues}
|
96
|
-
self.getCoolingTowerVariableSpeeds.sort.each {|obj| obj.applySizingValues}
|
97
|
-
self.getEvaporativeCoolerDirectResearchSpecials.sort.each {|obj| obj.applySizingValues}
|
98
|
-
self.getEvaporativeCoolerIndirectResearchSpecials.sort.each {|obj| obj.applySizingValues}
|
99
|
-
self.getEvaporativeFluidCoolerSingleSpeeds.sort.each {|obj| obj.applySizingValues}
|
100
|
-
self.getHeatExchangerFluidToFluids.sort.each {|obj| obj.applySizingValues}
|
101
|
-
self.getHumidifierSteamElectrics.sort.each {|obj| obj.applySizingValues}
|
102
|
-
self.getZoneHVACBaseboardConvectiveElectrics.sort.each {|obj| obj.applySizingValues}
|
103
|
-
self.getZoneHVACBaseboardConvectiveWaters.sort.each {|obj| obj.applySizingValues}
|
104
|
-
self.getZoneHVACFourPipeFanCoils.sort.each {|obj| obj.applySizingValues}
|
105
|
-
self.getZoneHVACHighTemperatureRadiants.sort.each {|obj| obj.applySizingValues}
|
106
|
-
self.getZoneHVACIdealLoadsAirSystems.sort.each {|obj| obj.applySizingValues}
|
107
|
-
self.getZoneHVACLowTemperatureRadiantElectrics.sort.each {|obj| obj.applySizingValues}
|
108
|
-
self.getZoneHVACLowTempRadiantConstFlows.sort.each {|obj| obj.applySizingValues}
|
109
|
-
self.getZoneHVACLowTempRadiantVarFlows.sort.each {|obj| obj.applySizingValues}
|
110
|
-
self.getZoneHVACPackagedTerminalAirConditioners.sort.each {|obj| obj.applySizingValues}
|
111
|
-
self.getZoneHVACPackagedTerminalHeatPumps.sort.each {|obj| obj.applySizingValues}
|
112
|
-
self.getZoneHVACTerminalUnitVariableRefrigerantFlows.sort.each {|obj| obj.applySizingValues}
|
113
|
-
self.getZoneHVACWaterToAirHeatPumps.sort.each {|obj| obj.applySizingValues}
|
114
|
-
|
115
|
-
# Zone equipment
|
116
|
-
|
117
|
-
# Air terminals
|
118
|
-
self.getAirTerminalSingleDuctParallelPIUReheats.sort.each {|obj| obj.applySizingValues}
|
119
|
-
self.getAirTerminalSingleDuctVAVReheats.sort.each {|obj| obj.applySizingValues}
|
120
|
-
self.getAirTerminalSingleDuctUncontrolleds.sort.each {|obj| obj.applySizingValues}
|
121
|
-
|
122
|
-
# AirLoopHVAC components
|
123
|
-
self.getAirLoopHVACs.sort.each {|obj| obj.applySizingValues}
|
124
|
-
self.getSizingSystems.sort.each {|obj| obj.applySizingValues}
|
125
|
-
|
126
|
-
# Fans
|
127
|
-
self.getFanConstantVolumes.sort.each {|obj| obj.applySizingValues}
|
128
|
-
self.getFanVariableVolumes.sort.each {|obj| obj.applySizingValues}
|
129
|
-
self.getFanOnOffs.sort.each {|obj| obj.applySizingValues}
|
130
|
-
|
131
|
-
# Heating coils
|
132
|
-
self.getCoilHeatingElectrics.sort.each {|obj| obj.applySizingValues}
|
133
|
-
self.getCoilHeatingGass.sort.each {|obj| obj.applySizingValues}
|
134
|
-
self.getCoilHeatingGasMultiStages.sort.each {|obj| obj.applySizingValues}
|
135
|
-
self.getCoilHeatingWaters.sort.each {|obj| obj.applySizingValues}
|
136
|
-
self.getCoilHeatingDXSingleSpeeds.sort.each {|obj| obj.applySizingValues}
|
137
|
-
self.getCoilHeatingDXMultiSpeeds.sort.each {|obj| obj.applySizingValues}
|
138
|
-
|
139
|
-
# Cooling coils
|
140
|
-
self.getCoilCoolingDXSingleSpeeds.sort.each {|obj| obj.applySizingValues}
|
141
|
-
self.getCoilCoolingDXTwoSpeeds.sort.each {|obj| obj.applySizingValues}
|
142
|
-
self.getCoilCoolingWaters.sort.each {|obj| obj.applySizingValues}
|
143
|
-
self.getCoilCoolingDXMultiSpeeds.sort.each {|obj| obj.applySizingValues}
|
144
|
-
|
145
|
-
# Outdoor air
|
146
|
-
self.getControllerOutdoorAirs.sort.each {|obj| obj.applySizingValues}
|
147
|
-
self.getHeatExchangerAirToAirSensibleAndLatents.sort.each {|obj| obj.applySizingValues}
|
148
|
-
|
149
|
-
# PlantLoop components
|
150
|
-
self.getPlantLoops.sort.each {|obj| obj.applySizingValues}
|
151
|
-
|
152
|
-
# Pumps
|
153
|
-
self.getPumpConstantSpeeds.sort.each {|obj| obj.applySizingValues}
|
154
|
-
self.getPumpVariableSpeeds.sort.each {|obj| obj.applySizingValues}
|
155
|
-
|
156
|
-
# Heating equipment
|
157
|
-
self.getBoilerHotWaters.sort.each {|obj| obj.applySizingValues}
|
158
|
-
|
159
|
-
# Cooling equipment
|
160
|
-
self.getChillerElectricEIRs.sort.each {|obj| obj.applySizingValues}
|
161
|
-
|
162
|
-
# Condenser equipment
|
163
|
-
self.getCoolingTowerSingleSpeeds.sort.each {|obj| obj.applySizingValues}
|
164
|
-
|
165
|
-
# Controls
|
166
|
-
self.getControllerWaterCoils.sort.each {|obj| obj.applySizingValues}
|
167
|
-
|
168
|
-
# VRF components
|
169
|
-
|
170
|
-
# Refrigeration components
|
171
|
-
|
172
|
-
return true
|
173
|
-
|
174
|
-
end
|
175
|
-
|
176
|
-
# Changes all hard-sized HVAC values to Autosized
|
177
|
-
def autosize
|
178
|
-
|
179
|
-
# @todo Sizing methods for these types of equipment are
|
180
|
-
# currently only stubs that need to be filled in.
|
181
|
-
self.getAirConditionerVariableRefrigerantFlows.sort.each {|obj| obj.autosize}
|
182
|
-
self.getAirLoopHVACUnitaryHeatCoolVAVChangeoverBypasss.sort.each {|obj| obj.autosize}
|
183
|
-
self.getAirLoopHVACUnitarySystems.sort.each {|obj| obj.autosize}
|
184
|
-
self.getAirTerminalSingleDuctConstantVolumeCooledBeams.sort.each {|obj| obj.autosize}
|
185
|
-
self.getAirTerminalSingleDuctConstantVolumeFourPipeInductions.sort.each {|obj| obj.autosize}
|
186
|
-
self.getAirTerminalSingleDuctConstantVolumeReheats.sort.each {|obj| obj.autosize}
|
187
|
-
self.getAirTerminalSingleDuctSeriesPIUReheats.sort.each {|obj| obj.autosize}
|
188
|
-
self.getAirTerminalSingleDuctVAVHeatAndCoolNoReheats.sort.each {|obj| obj.autosize}
|
189
|
-
self.getAirTerminalSingleDuctVAVHeatAndCoolReheats.sort.each {|obj| obj.autosize}
|
190
|
-
self.getBoilerSteams.sort.each {|obj| obj.autosize}
|
191
|
-
self.getCoilCoolingDXMultiSpeeds.sort.each {|obj| obj.autosize}
|
192
|
-
self.getCoilCoolingDXVariableRefrigerantFlows.sort.each {|obj| obj.autosize}
|
193
|
-
self.getCoilCoolingWaterToAirHeatPumpEquationFits.sort.each {|obj| obj.autosize}
|
194
|
-
self.getCoilHeatingWaterToAirHeatPumpEquationFits.sort.each {|obj| obj.autosize}
|
195
|
-
self.getCoilHeatingGasMultiStages.sort.each {|obj| obj.autosize}
|
196
|
-
self.getCoilHeatingDesuperheaters.sort.each {|obj| obj.autosize}
|
197
|
-
self.getCoilHeatingDXVariableRefrigerantFlows.sort.each {|obj| obj.autosize}
|
198
|
-
self.getCoilWaterHeatingDesuperheaters.sort.each {|obj| obj.autosize}
|
199
|
-
self.getCoolingTowerTwoSpeeds.sort.each {|obj| obj.autosize}
|
200
|
-
self.getCoolingTowerVariableSpeeds.sort.each {|obj| obj.autosize}
|
201
|
-
self.getEvaporativeCoolerDirectResearchSpecials.sort.each {|obj| obj.autosize}
|
202
|
-
self.getEvaporativeCoolerIndirectResearchSpecials.sort.each {|obj| obj.autosize}
|
203
|
-
self.getEvaporativeFluidCoolerSingleSpeeds.sort.each {|obj| obj.autosize}
|
204
|
-
self.getHeatExchangerFluidToFluids.sort.each {|obj| obj.autosize}
|
205
|
-
self.getHumidifierSteamElectrics.sort.each {|obj| obj.autosize}
|
206
|
-
self.getZoneHVACBaseboardConvectiveElectrics.sort.each {|obj| obj.autosize}
|
207
|
-
self.getZoneHVACBaseboardConvectiveWaters.sort.each {|obj| obj.autosize}
|
208
|
-
self.getZoneHVACFourPipeFanCoils.sort.each {|obj| obj.autosize}
|
209
|
-
self.getZoneHVACHighTemperatureRadiants.sort.each {|obj| obj.autosize}
|
210
|
-
self.getZoneHVACIdealLoadsAirSystems.sort.each {|obj| obj.autosize}
|
211
|
-
self.getZoneHVACLowTemperatureRadiantElectrics.sort.each {|obj| obj.autosize}
|
212
|
-
self.getZoneHVACLowTempRadiantConstFlows.sort.each {|obj| obj.autosize}
|
213
|
-
self.getZoneHVACLowTempRadiantVarFlows.sort.each {|obj| obj.autosize}
|
214
|
-
self.getZoneHVACPackagedTerminalAirConditioners.sort.each {|obj| obj.autosize}
|
215
|
-
self.getZoneHVACPackagedTerminalHeatPumps.sort.each {|obj| obj.autosize}
|
216
|
-
self.getZoneHVACTerminalUnitVariableRefrigerantFlows.sort.each {|obj| obj.autosize}
|
217
|
-
self.getZoneHVACWaterToAirHeatPumps.sort.each {|obj| obj.autosize}
|
218
|
-
|
219
|
-
# Zone equipment
|
220
|
-
|
221
|
-
# Air terminals
|
222
|
-
self.getAirTerminalSingleDuctParallelPIUReheats.sort.each {|obj| obj.autosize}
|
223
|
-
self.getAirTerminalSingleDuctVAVReheats.sort.each {|obj| obj.autosize}
|
224
|
-
self.getAirTerminalSingleDuctUncontrolleds.sort.each {|obj| obj.autosize}
|
225
|
-
|
226
|
-
# AirLoopHVAC components
|
227
|
-
self.getAirLoopHVACs.sort.each {|obj| obj.autosize}
|
228
|
-
self.getSizingSystems.sort.each {|obj| obj.autosize}
|
229
|
-
|
230
|
-
# Fans
|
231
|
-
self.getFanConstantVolumes.sort.each {|obj| obj.autosize}
|
232
|
-
self.getFanVariableVolumes.sort.each {|obj| obj.autosize}
|
233
|
-
self.getFanOnOffs.sort.each {|obj| obj.autosize}
|
234
|
-
|
235
|
-
# Heating coils
|
236
|
-
self.getCoilHeatingElectrics.sort.each {|obj| obj.autosize}
|
237
|
-
self.getCoilHeatingGass.sort.each {|obj| obj.autosize}
|
238
|
-
self.getCoilHeatingWaters.sort.each {|obj| obj.autosize}
|
239
|
-
self.getCoilHeatingDXSingleSpeeds.sort.each {|obj| obj.autosize}
|
240
|
-
|
241
|
-
# Cooling coils
|
242
|
-
self.getCoilCoolingDXSingleSpeeds.sort.each {|obj| obj.autosize}
|
243
|
-
self.getCoilCoolingDXTwoSpeeds.sort.each {|obj| obj.autosize}
|
244
|
-
self.getCoilCoolingWaters.sort.each {|obj| obj.autosize}
|
245
|
-
|
246
|
-
# Outdoor air
|
247
|
-
self.getControllerOutdoorAirs.sort.each {|obj| obj.autosize}
|
248
|
-
self.getHeatExchangerAirToAirSensibleAndLatents.sort.each {|obj| obj.autosize}
|
249
|
-
|
250
|
-
# PlantLoop components
|
251
|
-
self.getPlantLoops.sort.each {|obj| obj.autosize}
|
252
|
-
|
253
|
-
# Pumps
|
254
|
-
self.getPumpConstantSpeeds.sort.each {|obj| obj.autosize}
|
255
|
-
self.getPumpVariableSpeeds.sort.each {|obj| obj.autosize}
|
256
|
-
|
257
|
-
# Heating equipment
|
258
|
-
self.getBoilerHotWaters.sort.each {|obj| obj.autosize}
|
259
|
-
|
260
|
-
# Cooling equipment
|
261
|
-
self.getChillerElectricEIRs.sort.each {|obj| obj.autosize}
|
262
|
-
|
263
|
-
# Condenser equipment
|
264
|
-
self.getCoolingTowerSingleSpeeds.sort.each {|obj| obj.autosize}
|
265
|
-
|
266
|
-
# Controls
|
267
|
-
self.getControllerWaterCoils.sort.each {|obj| obj.autosize}
|
268
|
-
|
269
|
-
# VRF components
|
270
|
-
|
271
|
-
# Refrigeration components
|
272
|
-
|
273
|
-
return true
|
274
|
-
|
275
|
-
end
|
276
|
-
|
277
|
-
|
278
|
-
# A helper method to get component sizes from the model
|
279
|
-
# returns the autosized value as an optional double
|
280
|
-
def getAutosizedValue(object, value_name, units)
|
281
|
-
|
282
|
-
result = OpenStudio::OptionalDouble.new
|
283
|
-
|
284
|
-
name = object.name.get.upcase.strip
|
285
|
-
|
286
|
-
object_type = object.iddObject.type.valueDescription.gsub('OS:','')
|
287
|
-
|
288
|
-
# Special logic for two coil types which are inconsistently
|
289
|
-
# uppercase in the sqlfile:
|
290
|
-
object_type = object_type.upcase if object_type == 'Coil:Cooling:WaterToAirHeatPump:EquationFit'
|
291
|
-
object_type = object_type.upcase if object_type == 'Coil:Heating:WaterToAirHeatPump:EquationFit'
|
292
|
-
object_type = 'Coil:Heating:GasMultiStage' if object_type == 'Coil:Heating:Gas:MultiStage'
|
293
|
-
object_type = 'Coil:Heating:Fuel' if object_type == 'Coil:Heating:Gas'
|
294
|
-
|
295
|
-
sql = self.sqlFile
|
296
|
-
|
297
|
-
if sql.is_initialized
|
298
|
-
sql = sql.get
|
299
|
-
|
300
|
-
#SELECT * FROM ComponentSizes WHERE CompType = 'Coil:Heating:Gas' AND CompName = "COIL HEATING GAS 3" AND Description = "Design Size Nominal Capacity"
|
301
|
-
query = "SELECT Value
|
302
|
-
FROM ComponentSizes
|
303
|
-
WHERE CompType='#{object_type}'
|
304
|
-
AND CompName='#{name}'
|
305
|
-
AND Description='#{value_name.strip}'
|
306
|
-
AND Units='#{units}'"
|
307
|
-
|
308
|
-
val = sql.execAndReturnFirstDouble(query)
|
309
|
-
|
310
|
-
if val.is_initialized
|
311
|
-
result = OpenStudio::OptionalDouble.new(val.get)
|
312
|
-
else
|
313
|
-
# @todo comment following line (debugging new HVACsizing objects right now)
|
314
|
-
# OpenStudio::logFree(OpenStudio::Warn, "openstudio.model.Model", "QUERY ERROR: Data not found for query: #{query}")
|
315
|
-
end
|
316
|
-
else
|
317
|
-
OpenStudio::logFree(OpenStudio::Error, 'openstudio.model.Model', 'Model has no sql file containing results, cannot lookup data.')
|
318
|
-
end
|
319
|
-
|
320
|
-
return result
|
321
|
-
end
|
322
23
|
|
323
24
|
# A helper method to get component sizes from the Equipment Summary of the TabularDataWithStrings Report
|
324
25
|
# returns the autosized value as an optional double
|