openstudio-standards 0.2.15 → 0.2.16.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (94) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAEHighriseApartment.osm +0 -27
  3. data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
  4. data/data/standards/OpenStudio_Standards-ashrae_90_1_28Jan2022.xlsx +0 -0
  5. data/data/standards/test_performance_expected_dd_results.csv +710 -710
  6. data/lib/openstudio-standards/btap/btap_result.rb +2 -2
  7. data/lib/openstudio-standards/btap/reporting.rb +2 -2
  8. data/lib/openstudio-standards/btap/simmanager.rb +2 -2
  9. data/lib/openstudio-standards/hvac_sizing/Siz.ControllerOutdoorAir.rb +0 -54
  10. data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +11 -1
  11. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +1 -1
  12. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +26 -5
  13. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +35 -16
  14. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +23 -10
  15. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +36 -0
  16. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +6 -6
  17. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +0 -3
  18. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +2 -2
  19. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -3
  20. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +2 -0
  21. data/lib/openstudio-standards/standards/Standards.Construction.rb +12 -6
  22. data/lib/openstudio-standards/standards/Standards.Model.rb +38 -7
  23. data/lib/openstudio-standards/standards/Standards.Space.rb +1 -1
  24. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +7 -0
  25. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model.rb +32 -11
  26. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +22 -742
  27. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +2 -2
  28. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +3 -3
  29. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +6 -6
  30. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +19 -559
  31. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +2 -2
  32. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +3 -3
  33. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +6 -6
  34. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +19 -559
  35. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +2 -2
  36. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +5 -5
  37. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +7 -7
  38. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +19 -559
  39. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +2 -2
  40. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +5 -5
  41. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +7 -7
  42. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_properties.json +370 -910
  43. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_sets.json +2 -2
  44. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.prototype_inputs.json +6 -6
  45. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_system.json +0 -8
  46. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +12 -12
  47. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +19 -6
  48. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_properties.json +2380 -1300
  49. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_sets.json +2 -2
  50. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.prototype_inputs.json +6 -6
  51. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_system.json +0 -8
  52. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +12 -12
  53. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +140 -0
  54. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +1176 -312
  55. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.construction_properties.json +172 -1132
  56. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.construction_sets.json +14 -14
  57. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +2 -2
  58. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +9 -9
  59. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.construction_properties.json +180 -1140
  60. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.construction_sets.json +14 -14
  61. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +2 -2
  62. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +10 -10
  63. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.construction_properties.json +9 -9
  64. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.construction_properties.json +9 -9
  65. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +12 -6
  66. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +12 -6
  67. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +16 -8
  68. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +10 -20
  69. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +209 -37
  70. data/lib/openstudio-standards/standards/necb/ECMS/loads.rb +1 -0
  71. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +8 -6
  72. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +16 -9
  73. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartment.osm +1 -1
  74. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +1 -1
  75. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/MidriseApartment.osm +1 -1
  76. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +9 -5
  77. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +10 -6
  78. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +9 -5
  79. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +14 -8
  80. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +14 -8
  81. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +13 -6
  82. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +12 -6
  83. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +4 -2
  84. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +38 -19
  85. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +2 -2
  86. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +15 -4
  87. data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +10 -651
  88. data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +8 -38
  89. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +159 -0
  90. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +41 -43
  91. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +7 -4
  92. data/lib/openstudio-standards/version.rb +1 -1
  93. data/lib/openstudio-standards.rb +1 -0
  94. metadata +4 -2
@@ -1,16 +1,37 @@
1
1
  class ASHRAE9012004 < ASHRAE901
2
2
  # @!group Model
3
+ #
4
+ # Determine the surface range of a baseline model.
5
+ # The method calculates the window to wall ratio (assuming all spaces are conditioned)
6
+ # and select the range based on the calculated window to wall ratio
7
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
8
+ # @param intended_surface_type [String] intended surface type
9
+ def model_get_percent_of_surface_range(model, intended_surface_type)
10
+ wwr_range = {}
3
11
 
4
- # Determine which climate zone to use.
5
- # Uses the most specific climate zone set for most
6
- # climate zones, except for ClimateZone 3, which
7
- # uses the least specific climate zone.
8
- def model_get_climate_zone_set_from_list(model, possible_climate_zone_sets)
9
- climate_zone_set = if possible_climate_zone_sets.include? 'ClimateZone 3'
10
- possible_climate_zone_sets.max
11
- else
12
- possible_climate_zone_sets.min
13
- end
14
- return climate_zone_set
12
+ # Do not process surfaces other than exterior windows and glass door for 2004 standard
13
+ if intended_surface_type != 'ExteriorWindow' && intended_surface_type != 'GlassDoor'
14
+ wwr_range['minimum_percent_of_surface'] = nil
15
+ wwr_range['maximum_percent_of_surface'] = nil
16
+ else
17
+ wwr = model_get_window_area_info(model, true)
18
+ if wwr <= 10
19
+ wwr_range['minimum_percent_of_surface'] = 1.0
20
+ wwr_range['maximum_percent_of_surface'] = 10.0
21
+ elsif wwr <= 20
22
+ wwr_range['minimum_percent_of_surface'] = 10.001
23
+ wwr_range['maximum_percent_of_surface'] = 20
24
+ elsif wwr <= 30
25
+ wwr_range['minimum_percent_of_surface'] = 20.001
26
+ wwr_range['maximum_percent_of_surface'] = 30
27
+ elsif wwr <= 40
28
+ wwr_range['minimum_percent_of_surface'] = 30.001
29
+ wwr_range['maximum_percent_of_surface'] = 40
30
+ else
31
+ wwr_range['minimum_percent_of_surface'] = 40.001
32
+ wwr_range['maximum_percent_of_surface'] = 100.0
33
+ end
34
+ end
35
+ return wwr_range
15
36
  end
16
37
  end