openstudio-standards 0.2.15 → 0.2.16.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (94) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAEHighriseApartment.osm +0 -27
  3. data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
  4. data/data/standards/OpenStudio_Standards-ashrae_90_1_28Jan2022.xlsx +0 -0
  5. data/data/standards/test_performance_expected_dd_results.csv +710 -710
  6. data/lib/openstudio-standards/btap/btap_result.rb +2 -2
  7. data/lib/openstudio-standards/btap/reporting.rb +2 -2
  8. data/lib/openstudio-standards/btap/simmanager.rb +2 -2
  9. data/lib/openstudio-standards/hvac_sizing/Siz.ControllerOutdoorAir.rb +0 -54
  10. data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +11 -1
  11. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +1 -1
  12. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +26 -5
  13. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +35 -16
  14. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +23 -10
  15. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +36 -0
  16. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +6 -6
  17. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +0 -3
  18. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +2 -2
  19. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -3
  20. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +2 -0
  21. data/lib/openstudio-standards/standards/Standards.Construction.rb +12 -6
  22. data/lib/openstudio-standards/standards/Standards.Model.rb +38 -7
  23. data/lib/openstudio-standards/standards/Standards.Space.rb +1 -1
  24. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +7 -0
  25. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model.rb +32 -11
  26. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +22 -742
  27. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +2 -2
  28. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +3 -3
  29. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +6 -6
  30. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +19 -559
  31. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +2 -2
  32. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +3 -3
  33. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +6 -6
  34. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +19 -559
  35. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +2 -2
  36. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +5 -5
  37. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +7 -7
  38. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +19 -559
  39. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +2 -2
  40. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +5 -5
  41. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +7 -7
  42. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_properties.json +370 -910
  43. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_sets.json +2 -2
  44. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.prototype_inputs.json +6 -6
  45. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_system.json +0 -8
  46. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +12 -12
  47. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +19 -6
  48. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_properties.json +2380 -1300
  49. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_sets.json +2 -2
  50. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.prototype_inputs.json +6 -6
  51. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_system.json +0 -8
  52. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +12 -12
  53. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +140 -0
  54. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +1176 -312
  55. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.construction_properties.json +172 -1132
  56. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.construction_sets.json +14 -14
  57. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +2 -2
  58. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +9 -9
  59. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.construction_properties.json +180 -1140
  60. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.construction_sets.json +14 -14
  61. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +2 -2
  62. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +10 -10
  63. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.construction_properties.json +9 -9
  64. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.construction_properties.json +9 -9
  65. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +12 -6
  66. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +12 -6
  67. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +16 -8
  68. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +10 -20
  69. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +209 -37
  70. data/lib/openstudio-standards/standards/necb/ECMS/loads.rb +1 -0
  71. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +8 -6
  72. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +16 -9
  73. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartment.osm +1 -1
  74. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +1 -1
  75. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/MidriseApartment.osm +1 -1
  76. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +9 -5
  77. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +10 -6
  78. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +9 -5
  79. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +14 -8
  80. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +14 -8
  81. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +13 -6
  82. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +12 -6
  83. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +4 -2
  84. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +38 -19
  85. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +2 -2
  86. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +15 -4
  87. data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +10 -651
  88. data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +8 -38
  89. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +159 -0
  90. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +41 -43
  91. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +7 -4
  92. data/lib/openstudio-standards/version.rb +1 -1
  93. data/lib/openstudio-standards.rb +1 -0
  94. metadata +4 -2
@@ -1349,7 +1349,7 @@
1349
1349
  "interior_ceilings": "Typical Interior Ceiling",
1350
1350
  "ground_contact_wall_standards_construction_type": null,
1351
1351
  "ground_contact_wall_building_category": null,
1352
- "ground_contact_floor_standards_construction_type": "Mass",
1352
+ "ground_contact_floor_standards_construction_type": "Unheated",
1353
1353
  "ground_contact_floor_building_category": "Adiabatic",
1354
1354
  "ground_contact_ceiling_standards_construction_type": null,
1355
1355
  "ground_contact_ceiling_building_category": null,
@@ -1392,7 +1392,7 @@
1392
1392
  "interior_ceilings": "Typical Interior Ceiling",
1393
1393
  "ground_contact_wall_standards_construction_type": null,
1394
1394
  "ground_contact_wall_building_category": null,
1395
- "ground_contact_floor_standards_construction_type": "Mass",
1395
+ "ground_contact_floor_standards_construction_type": "Unheated",
1396
1396
  "ground_contact_floor_building_category": "Adiabatic",
1397
1397
  "ground_contact_ceiling_standards_construction_type": null,
1398
1398
  "ground_contact_ceiling_building_category": null,
@@ -22,9 +22,9 @@
22
22
  "pszac_oa_damper_schedule_2": null,
23
23
  "pszac_operation_schedule_3": null,
24
24
  "pszac_oa_damper_schedule_3": null,
25
- "occ_sensing_exterior_lighting_power": null,
26
- "occ_sensing_exterior_lighting_schedule": null,
27
- "nondimming_exterior_lighting_power": null,
25
+ "occ_sensing_exterior_lighting_power": 8552.0,
26
+ "occ_sensing_exterior_lighting_schedule": "College EXTERIOR_LIGHT_SCH",
27
+ "nondimming_exterior_lighting_power": 441.8,
28
28
  "nondimming_exterior_lighting_schedule": "College EXTERIOR_LIGHT_SCH",
29
29
  "building_area_method_lpd": 0.82,
30
30
  "exterior_fuel_equipment1_power": null,
@@ -42,8 +42,8 @@
42
42
  "other_off_cycle_parasitic_heat_fraction_to_tank": null,
43
43
  "main_water_use_temperature": 140.0,
44
44
  "main_service_water_temperature_at_fixture": 140.0,
45
- "main_service_water_pump_head": null,
46
- "main_service_water_pump_motor_efficiency": null,
45
+ "main_service_water_pump_head": 29891.0,
46
+ "main_service_water_pump_motor_efficiency": 0.3,
47
47
  "main_service_water_parasitic_fuel_consumption_rate": 27797.29,
48
48
  "laundry_water_heater_volume": null,
49
49
  "laundry_water_heater_fuel": null,
@@ -345,7 +345,7 @@
345
345
  "main_water_heater_capacity": 600000.0,
346
346
  "main_service_water_temperature": 140.0,
347
347
  "main_service_water_flowrate_schedule": "ApartmentHighRise APT_DHW_SCH",
348
- "main_water_heater_space_name": "Ambient Temp Schedule",
348
+ "main_water_heater_space_name": null,
349
349
  "main_service_water_peak_flowrate": null,
350
350
  "main_off_cycle_parasitic_heat_fraction_to_tank": 0.8,
351
351
  "other_off_cycle_parasitic_heat_fraction_to_tank": 0.0,
@@ -1,13 +1,5 @@
1
1
  {
2
2
  "refrigeration_system": [
3
- {
4
- "template": "90.1-2016",
5
- "building_type": "College",
6
- "size_category": "Any",
7
- "system_type": "Low Temperature",
8
- "refrigerant": "R404a",
9
- "suctiontemperaturecontroltype": "ConstantSuctionTemperature"
10
- },
11
3
  {
12
4
  "template": "90.1-2016",
13
5
  "building_type": "FullServiceRestaurant",
@@ -129,8 +129,8 @@
129
129
  "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
130
130
  "additional_electric_equipment_schedule": null,
131
131
  "additional_gas_equipment_schedule": null,
132
- "occupancy_per_area": null,
133
- "occupancy_schedule": "College BLDG_OCC_SCH",
132
+ "occupancy_per_area": 20.0,
133
+ "occupancy_schedule": "College BLDG_Studio_OCC_SCH",
134
134
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
135
135
  "is_residential": null,
136
136
  "ventilation_standard": null,
@@ -218,7 +218,7 @@
218
218
  "additional_electric_equipment_schedule": null,
219
219
  "additional_gas_equipment_schedule": null,
220
220
  "occupancy_per_area": 65.0,
221
- "occupancy_schedule": "College BLDG_OCC_SCH",
221
+ "occupancy_schedule": "College BLDG_Class_OCC_SCH",
222
222
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
223
223
  "is_residential": null,
224
224
  "ventilation_standard": null,
@@ -646,7 +646,7 @@
646
646
  "additional_electric_equipment_schedule": null,
647
647
  "additional_gas_equipment_schedule": null,
648
648
  "occupancy_per_area": 25.0,
649
- "occupancy_schedule": "College BLDG_OCC_SCH",
649
+ "occupancy_schedule": "College BLDG_Lab_OCC_SCH",
650
650
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
651
651
  "is_residential": null,
652
652
  "ventilation_standard": null,
@@ -734,7 +734,7 @@
734
734
  "additional_electric_equipment_schedule": null,
735
735
  "additional_gas_equipment_schedule": null,
736
736
  "occupancy_per_area": 65.0,
737
- "occupancy_schedule": "College BLDG_OCC_SCH_Lecture Theater",
737
+ "occupancy_schedule": "College BLDG_Lecture_OCC_SCH",
738
738
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
739
739
  "is_residential": null,
740
740
  "ventilation_standard": null,
@@ -821,9 +821,9 @@
821
821
  "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
822
822
  "additional_electric_equipment_schedule": null,
823
823
  "additional_gas_equipment_schedule": null,
824
- "occupancy_per_area": null,
825
- "occupancy_schedule": null,
826
- "occupancy_activity_schedule": null,
824
+ "occupancy_per_area": 25.0,
825
+ "occupancy_schedule": "College BLDG_Cafe_OCC_SCH",
826
+ "occupancy_activity_schedule": "College ACTIVITY_SCH",
827
827
  "is_residential": null,
828
828
  "ventilation_standard": null,
829
829
  "ventilation_primary_space_type": null,
@@ -910,7 +910,7 @@
910
910
  "additional_electric_equipment_schedule": null,
911
911
  "additional_gas_equipment_schedule": null,
912
912
  "occupancy_per_area": 10.0,
913
- "occupancy_schedule": "College BLDG_OCC_SCH_Lecture Theater",
913
+ "occupancy_schedule": "College BLDG_Lecture_OCC_SCH",
914
914
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
915
915
  "is_residential": null,
916
916
  "ventilation_standard": null,
@@ -1237,9 +1237,9 @@
1237
1237
  "psa_nongeometry_fraction": null,
1238
1238
  "ssa_nongeometry_fraction": null,
1239
1239
  "notes": null,
1240
- "occupancy_per_area": 15.0,
1241
- "occupancy_schedule": "College BLDG_OCC_SCH",
1242
- "occupancy_activity_schedule": "College ACTIVITY_SCH",
1240
+ "occupancy_per_area": null,
1241
+ "occupancy_schedule": null,
1242
+ "occupancy_activity_schedule": null,
1243
1243
  "is_residential": null,
1244
1244
  "ventilation_standard": null,
1245
1245
  "ventilation_primary_space_type": null,
@@ -426,12 +426,19 @@ class ASHRAE9012019 < ASHRAE901
426
426
  search_criteria = {
427
427
  'template' => template,
428
428
  'climate_zone' => climate_zone,
429
- 'under_8000_hours' => true
429
+ 'under_8000_hours' => true,
430
+ 'nontransient_dwelling' => false,
431
+ 'enthalpy_recovery_ratio_design_conditions' => "Cooling"
430
432
  }
431
433
  energy_recovery_limits = model_find_object(standards_data['energy_recovery'], search_criteria)
432
434
  if energy_recovery_limits.nil?
433
- OpenStudio.logFree(OpenStudio::Warn, 'openstudio.ashrae_90_1_2019.AirLoopHVAC', "Cannot find energy recovery limits for template '#{template}', climate zone '#{climate_zone}', and under 8000 hours, assuming no energy recovery required.")
434
- return nil
435
+ # Repeat the search for heating
436
+ search_criteria['enthalpy_recovery_ratio_design_conditions'] = "Heating"
437
+ energy_recovery_limits = model_find_object(standards_data['energy_recovery'], search_criteria)
438
+ if energy_recovery_limits.nil?
439
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.ashrae_90_1_2019.AirLoopHVAC', "Cannot find energy recovery limits for template '#{template}', climate zone '#{climate_zone}', and under 8000 hours, assuming no energy recovery required.")
440
+ return nil
441
+ end
435
442
  end
436
443
 
437
444
  if pct_oa < 0.1
@@ -473,12 +480,18 @@ class ASHRAE9012019 < ASHRAE901
473
480
  'template' => template,
474
481
  'climate_zone' => climate_zone,
475
482
  'under_8000_hours' => false,
476
- 'nontransient_dwelling' => nontrans_dwel
483
+ 'nontransient_dwelling' => nontrans_dwel,
484
+ 'enthalpy_recovery_ratio_design_conditions' => "Cooling"
477
485
  }
478
486
  energy_recovery_limits = model_find_object(standards_data['energy_recovery'], search_criteria)
479
487
  if energy_recovery_limits.nil?
480
- OpenStudio.logFree(OpenStudio::Warn, 'openstudio.ashrae_90_1_2019.AirLoopHVAC', "Cannot find energy recovery limits for template '#{template}', climate zone '#{climate_zone}', and under 8000 hours, assuming no energy recovery required.")
481
- return nil
488
+ # Repeat the search for heating
489
+ search_criteria['enthalpy_recovery_ratio_design_conditions'] = "Heating"
490
+ energy_recovery_limits = model_find_object(standards_data['energy_recovery'], search_criteria)
491
+ if energy_recovery_limits.nil?
492
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.ashrae_90_1_2019.AirLoopHVAC', "Cannot find energy recovery limits for template '#{template}', climate zone '#{climate_zone}', and under 8000 hours, assuming no energy recovery required.")
493
+ return nil
494
+ end
482
495
  end
483
496
  if pct_oa < 0.1
484
497
  if nontrans_dwel