openstudio-standards 0.2.12 → 0.2.13.rc3
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAE90120162019HighriseApartment.json +1042 -0
- data/data/geometry/ASHRAE90120162019Hospital.json +199 -0
- data/data/geometry/ASHRAE90120162019LargeHotel.json +73 -0
- data/data/geometry/ASHRAE90120162019LargeOffice.json +109 -0
- data/data/geometry/ASHRAE90120162019SecondarySchool.json +205 -0
- data/data/geometry/ASHRAECourthouse.json +112 -0
- data/data/geometry/ASHRAECourthouse.osm +26470 -0
- data/data/geometry/ASHRAELargeHotel.osm +11 -1
- data/data/geometry/ASHRAELargeOffice.json +4 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/exclude_list.csv +19 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +293 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +25426 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +564 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +508 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +184 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +21446 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +293 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +564 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +466 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +137 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +184 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +21380 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +395 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +592 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +550 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +466 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +137 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +238 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +21548 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +64 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +871 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +592 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +1096 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +886 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +194 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +247 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +22079 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +994 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/manage_OpenStudio_Standards.rb +87 -37
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1-ALL-comstockspace_types.csv +236 -0
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +622 -0
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1space_types.csv +191 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +16 -25
- data/data/standards/test_performance_expected_dd_results.csv +1934 -1134
- data/lib/openstudio-standards.rb +68 -17
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +28 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +28 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +53 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +29 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +157 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +29 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +366 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +144 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +367 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +144 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +74 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +46 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +15 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +26 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +8 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +54 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +56 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +38 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +218 -134
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +6 -2
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +222 -133
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +60 -62
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +25 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +34 -22
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +31 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +43 -28
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +48 -38
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +9 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +567 -344
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +13 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +13 -17
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +9 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +79 -51
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +60 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +2 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +133 -120
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +124 -112
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +138 -66
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +7275 -199
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +35 -35
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +4 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +7 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +7 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +13 -14
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +7 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +2 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +0 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +25 -14
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +474 -89
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +35 -33
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +72 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +120 -120
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +103 -125
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +9 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +11 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +26 -14
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +270 -247
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/refs/references.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +41 -28
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +1 -0
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +2 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +8 -10
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -5
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +12 -9
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +3 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +0 -3
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +4 -7
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -3
- data/lib/openstudio-standards/standards/Standards.Construction.rb +124 -118
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -4
- data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +10 -3
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.Model.rb +282 -253
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -0
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -9
- data/lib/openstudio-standards/standards/Standards.Pump.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +103 -121
- data/lib/openstudio-standards/standards/Standards.Space.rb +42 -35
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +9 -17
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +25 -27
- data/lib/openstudio-standards/standards/Standards.Surface.rb +97 -52
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +39 -21
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +6 -7
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +15 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +0 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +10 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +2420 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +68 -38
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +105 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +5 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +68 -38
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +104 -17
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +25 -13
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +64 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +52 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +68 -38
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +112 -25
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +21 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +64 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +104 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +70 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +172 -55
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +456 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +189 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +57 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.boilers.json +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.chillers.json +490 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_properties.json +21244 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_sets.json +2111 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.economizers.json +676 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.elevators.json +372 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +1096 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +532 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_rejection.json +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.prototype_inputs.json +3094 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_cases.json +854 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_lnup.json +562 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_compressors.json +58 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_condenser.json +238 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_system.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_walkins.json +1316 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +23067 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +648 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +456 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +189 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +57 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.chillers.json +490 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_properties.json +21244 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_sets.json +2111 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.economizers.json +676 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.elevators.json +372 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +1096 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +664 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +204 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_rejection.json +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.prototype_inputs.json +3094 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_cases.json +854 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_lnup.json +562 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +58 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_condenser.json +238 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_system.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_walkins.json +1316 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +23067 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +671 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +1662 -332
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.materials.json +5049 -289
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +1743 -161
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +9 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ext_ltg.json +10 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +9 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +0 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +3 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -3
- data/lib/openstudio-standards/standards/cbes/cbes.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +8 -13
- data/lib/openstudio-standards/standards/deer/deer.Model.rb +2 -2
- data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +2 -0
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +0 -1
- data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +0 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +28 -7
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +16 -2
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +15 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +14 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/erv.json +11 -7
- data/lib/openstudio-standards/standards/necb/ECMS/data/pv.json +112 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/unitary_acs.json +50 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +21 -8
- data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +17 -6
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +142 -6
- data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +189 -0
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +104 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +19 -13
- data/lib/openstudio-standards/standards/necb/NECB2011/data/erv.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +39278 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +17 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +15 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +14 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +13 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +12 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +154 -12
- data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +21 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +140 -21
- data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +74 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/pv_ground.md +44 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/qaqc_resources/neb_end_use_prices.csv +39 -84
- data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +0 -1
- data/lib/openstudio-standards/standards/standard.rb +6 -5
- data/lib/openstudio-standards/utilities/Add_template_field_to_json.rb +3 -3
- data/lib/openstudio-standards/utilities/convert_surfaces_to_adiabatic_necb_8426.rb +54 -54
- data/lib/openstudio-standards/utilities/generate_prototype_database.rb +2 -2
- data/lib/openstudio-standards/utilities/generate_space_types.rb +3 -3
- data/lib/openstudio-standards/utilities/logging.rb +7 -7
- data/lib/openstudio-standards/utilities/necb_to_epw_map.rb +14 -14
- data/lib/openstudio-standards/utilities/os_sim_extract.rb +25 -25
- data/lib/openstudio-standards/utilities/rename_surfaces.rb +10 -13
- data/lib/openstudio-standards/utilities/round_surf_coords.rb +18 -20
- data/lib/openstudio-standards/utilities/sched_create.rb +39 -41
- data/lib/openstudio-standards/utilities/set_mult_to_adiabatic.rb +31 -31
- data/lib/openstudio-standards/utilities/simulation.rb +5 -3
- data/lib/openstudio-standards/utilities/speacetype_map_converter.rb +10 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +6 -8
- data/lib/openstudio-standards/utilities/template_measure/measure.rb +108 -0
- data/lib/openstudio-standards/utilities/template_measure/measure.xml +162 -0
- data/lib/openstudio-standards/utilities/template_measure/resources/BTAPMeasureHelper.rb +448 -0
- data/lib/openstudio-standards/utilities/template_measure/tests/test.rb +160 -0
- data/lib/openstudio-standards/utilities/weatherData1_xlsx_to_json.rb +23 -26
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +74 -80
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +17 -17
- metadata +217 -2
@@ -554,8 +554,8 @@ class Standard
|
|
554
554
|
if weather_file[0] == ':' # Running from OpenStudio CLI
|
555
555
|
# Attempt to load in the ddy file based on convention that it is in the same directory and has the same basename as the epw file.
|
556
556
|
ddy_file = weather_file.gsub('.epw', '.ddy')
|
557
|
-
if EmbeddedScripting
|
558
|
-
ddy_string = EmbeddedScripting
|
557
|
+
if EmbeddedScripting.hasFile(ddy_file)
|
558
|
+
ddy_string = EmbeddedScripting.getFileAsString(ddy_file)
|
559
559
|
temp_ddy_path = "#{Dir.pwd}/in.ddy"
|
560
560
|
File.open(temp_ddy_path, 'wb') { |f| f << ddy_string; f.flush }
|
561
561
|
ddy_model = OpenStudio::EnergyPlus.loadAndTranslateIdf(temp_ddy_path).get
|
@@ -746,11 +746,20 @@ class Standard
|
|
746
746
|
cooling_equipment.setName("#{heat_pump_water_loop.name} FluidCoolerSingleSpeed")
|
747
747
|
heat_pump_water_loop.addSupplyBranchForComponent(cooling_equipment)
|
748
748
|
cooling_equipment_stpt_manager.setName("#{heat_pump_water_loop.name} Fluid Cooler Scheduled Dual Setpoint")
|
749
|
+
# Remove hard coded default values
|
750
|
+
cooling_equipment.setPerformanceInputMethod('UFactorTimesAreaAndDesignWaterFlowRate')
|
751
|
+
cooling_equipment.autosizeDesignWaterFlowRate
|
752
|
+
cooling_equipment.autosizeDesignAirFlowRate
|
749
753
|
when 'FluidCoolerTwoSpeed'
|
750
754
|
cooling_equipment = OpenStudio::Model::FluidCoolerTwoSpeed.new(model)
|
751
755
|
cooling_equipment.setName("#{heat_pump_water_loop.name} FluidCoolerTwoSpeed")
|
752
756
|
heat_pump_water_loop.addSupplyBranchForComponent(cooling_equipment)
|
753
757
|
cooling_equipment_stpt_manager.setName("#{heat_pump_water_loop.name} Fluid Cooler Scheduled Dual Setpoint")
|
758
|
+
# Remove hard coded default values
|
759
|
+
cooling_equipment.setPerformanceInputMethod('UFactorTimesAreaAndDesignWaterFlowRate')
|
760
|
+
cooling_equipment.autosizeDesignWaterFlowRate
|
761
|
+
cooling_equipment.autosizeHighFanSpeedAirFlowRate
|
762
|
+
cooling_equipment.autosizeLowFanSpeedAirFlowRate
|
754
763
|
when 'EvaporativeFluidCooler', 'EvaporativeFluidCoolerSingleSpeed'
|
755
764
|
cooling_equipment = OpenStudio::Model::EvaporativeFluidCoolerSingleSpeed.new(model)
|
756
765
|
cooling_equipment.setName("#{heat_pump_water_loop.name} EvaporativeFluidCoolerSingleSpeed")
|
@@ -895,7 +904,7 @@ class Standard
|
|
895
904
|
# sensor to read supply inlet temperature
|
896
905
|
inlet_temp_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model,
|
897
906
|
'System Node Temperature')
|
898
|
-
inlet_temp_sensor.setName("#{ground_hx.name.to_s.gsub(/[ +-.]/,'_')} Inlet Temp Sensor")
|
907
|
+
inlet_temp_sensor.setName("#{ground_hx.name.to_s.gsub(/[ +-.]/, '_')} Inlet Temp Sensor")
|
899
908
|
inlet_temp_sensor.setKeyName(ground_hx_loop.supplyInletNode.handle.to_s)
|
900
909
|
|
901
910
|
# actuator to set supply outlet temperature
|
@@ -907,7 +916,7 @@ class Standard
|
|
907
916
|
# program to control outlet temperature
|
908
917
|
# adjusts delta-t based on calculation of slope and intercept from control temperatures
|
909
918
|
program = OpenStudio::Model::EnergyManagementSystemProgram.new(model)
|
910
|
-
program.setName("#{ground_hx.name.to_s.gsub(/[ +-.]/,'_')} Temperature Control")
|
919
|
+
program.setName("#{ground_hx.name.to_s.gsub(/[ +-.]/, '_')} Temperature Control")
|
911
920
|
program_body = <<-EMS
|
912
921
|
SET Tin = #{inlet_temp_sensor.handle}
|
913
922
|
SET Tout = #{slope_c_per_c.round(2)} * Tin + #{intercept_c.round(1)}
|
@@ -917,7 +926,7 @@ class Standard
|
|
917
926
|
|
918
927
|
# program calling manager
|
919
928
|
pcm = OpenStudio::Model::EnergyManagementSystemProgramCallingManager.new(model)
|
920
|
-
pcm.setName("#{program.name.to_s.gsub(/[ +-.]/,'_')} Calling Manager")
|
929
|
+
pcm.setName("#{program.name.to_s.gsub(/[ +-.]/, '_')} Calling Manager")
|
921
930
|
pcm.setCallingPoint('InsideHVACSystemIterationLoop')
|
922
931
|
pcm.addProgram(program)
|
923
932
|
|
@@ -1484,7 +1493,7 @@ class Standard
|
|
1484
1493
|
end
|
1485
1494
|
# VAV reheat terminal
|
1486
1495
|
air_terminal = OpenStudio::Model::AirTerminalSingleDuctVAVReheat.new(model, model.alwaysOnDiscreteSchedule, rht_coil)
|
1487
|
-
air_terminal.
|
1496
|
+
air_terminal.setZoneMinimumAirFlowInputMethod('Constant')
|
1488
1497
|
air_terminal.setControlForOutdoorAir(true) if demand_control_ventilation
|
1489
1498
|
else # 'DOASVAV'
|
1490
1499
|
air_terminal = OpenStudio::Model::AirTerminalSingleDuctVAVNoReheat.new(model, model.alwaysOnDiscreteSchedule)
|
@@ -1727,7 +1736,7 @@ class Standard
|
|
1727
1736
|
# create vav terminal
|
1728
1737
|
terminal = OpenStudio::Model::AirTerminalSingleDuctVAVReheat.new(model, model.alwaysOnDiscreteSchedule, rht_coil)
|
1729
1738
|
terminal.setName("#{zone.name} VAV Terminal")
|
1730
|
-
terminal.
|
1739
|
+
terminal.setZoneMinimumAirFlowInputMethod('Constant')
|
1731
1740
|
terminal.setMaximumFlowFractionDuringReheat(0.5)
|
1732
1741
|
terminal.setMaximumReheatAirTemperature(dsgn_temps['zn_htg_dsgn_sup_air_temp_c'])
|
1733
1742
|
air_loop.multiAddBranchForZone(zone, terminal.to_HVACComponent.get)
|
@@ -2058,7 +2067,7 @@ class Standard
|
|
2058
2067
|
# create VAV terminal
|
2059
2068
|
terminal = OpenStudio::Model::AirTerminalSingleDuctVAVReheat.new(model, model.alwaysOnDiscreteSchedule, rht_coil)
|
2060
2069
|
terminal.setName("#{zone.name} VAV Terminal")
|
2061
|
-
terminal.
|
2070
|
+
terminal.setZoneMinimumAirFlowInputMethod('Constant')
|
2062
2071
|
terminal.setMaximumReheatAirTemperature(dsgn_temps['zn_htg_dsgn_sup_air_temp_c'])
|
2063
2072
|
air_loop.multiAddBranchForZone(zone, terminal.to_HVACComponent.get)
|
2064
2073
|
air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(terminal, thermal_zone_outdoor_airflow_rate_per_area(zone))
|
@@ -2357,7 +2366,7 @@ class Standard
|
|
2357
2366
|
# VAV terminal
|
2358
2367
|
terminal = OpenStudio::Model::AirTerminalSingleDuctVAVReheat.new(model, model.alwaysOnDiscreteSchedule, rht_coil)
|
2359
2368
|
terminal.setName("#{zone.name} VAV Terminal")
|
2360
|
-
terminal.
|
2369
|
+
terminal.setZoneMinimumAirFlowInputMethod('Constant')
|
2361
2370
|
terminal.setMaximumFlowPerZoneFloorAreaDuringReheat(0.0)
|
2362
2371
|
terminal.setMaximumFlowFractionDuringReheat(0.5)
|
2363
2372
|
terminal.setMaximumReheatAirTemperature(dsgn_temps['zn_htg_dsgn_sup_air_temp_c'])
|
@@ -2551,110 +2560,65 @@ class Standard
|
|
2551
2560
|
clg_coil = nil
|
2552
2561
|
end
|
2553
2562
|
|
2554
|
-
#
|
2555
|
-
|
2556
|
-
|
2563
|
+
# Use a Fan:OnOff in the unitary system object
|
2564
|
+
case fan_type
|
2565
|
+
when 'Cycling'
|
2557
2566
|
fan = create_fan_by_name(model,
|
2558
2567
|
'Packaged_RTU_SZ_AC_Cycling_Fan',
|
2559
2568
|
fan_name: "#{air_loop.name} Fan")
|
2560
|
-
|
2561
|
-
|
2562
|
-
|
2563
|
-
|
2564
|
-
unitary_system.setSupplyFan(fan) unless fan.nil?
|
2565
|
-
unitary_system.setHeatingCoil(htg_coil) unless htg_coil.nil?
|
2566
|
-
unitary_system.setCoolingCoil(clg_coil) unless clg_coil.nil?
|
2567
|
-
unitary_system.setSupplementalHeatingCoil(supplemental_htg_coil) unless supplemental_htg_coil.nil?
|
2568
|
-
unitary_system.setName("#{zone.name} Unitary HP")
|
2569
|
-
unitary_system.setControllingZoneorThermostatLocation(zone)
|
2570
|
-
unitary_system.setMaximumSupplyAirTemperature(dsgn_temps['zn_htg_dsgn_sup_air_temp_c'])
|
2571
|
-
unitary_system.setFanPlacement('BlowThrough')
|
2572
|
-
unitary_system.setSupplyAirFlowRateMethodDuringCoolingOperation('SupplyAirFlowRate')
|
2573
|
-
unitary_system.setSupplyAirFlowRateMethodDuringHeatingOperation('SupplyAirFlowRate')
|
2574
|
-
unitary_system.setSupplyAirFlowRateMethodWhenNoCoolingorHeatingisRequired('SupplyAirFlowRate')
|
2575
|
-
unitary_system.setSupplyAirFanOperatingModeSchedule(model.alwaysOffDiscreteSchedule)
|
2576
|
-
unitary_system.addToNode(air_loop.supplyInletNode)
|
2577
|
-
when 'Single Speed Heat Pump'
|
2578
|
-
# CyclingHeatPump: Unitary Heat Pump system
|
2579
|
-
unitary_system = OpenStudio::Model::AirLoopHVACUnitarySystem.new(model)
|
2580
|
-
unitary_system.setAvailabilitySchedule(model.alwaysOnDiscreteSchedule)
|
2581
|
-
unitary_system.setSupplyFan(fan) unless fan.nil?
|
2582
|
-
unitary_system.setHeatingCoil(htg_coil) unless htg_coil.nil?
|
2583
|
-
unitary_system.setCoolingCoil(clg_coil) unless clg_coil.nil?
|
2584
|
-
unitary_system.setSupplementalHeatingCoil(supplemental_htg_coil) unless supplemental_htg_coil.nil?
|
2585
|
-
unitary_system.setName("#{air_loop.name} Unitary HP")
|
2586
|
-
unitary_system.setControllingZoneorThermostatLocation(zone)
|
2587
|
-
unitary_system.setMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation(OpenStudio.convert(40.0, 'F', 'C').get)
|
2588
|
-
unitary_system.setFanPlacement(fan_location)
|
2589
|
-
unitary_system.setSupplyAirFanOperatingModeSchedule(model.alwaysOffDiscreteSchedule)
|
2590
|
-
unitary_system.addToNode(air_loop.supplyInletNode)
|
2591
|
-
else
|
2592
|
-
# heating_type = NaturalGas, Electricity, Water or nil (no heat)
|
2593
|
-
unitary_system = OpenStudio::Model::AirLoopHVACUnitarySystem.new(model)
|
2594
|
-
unitary_system.setAvailabilitySchedule(model.alwaysOnDiscreteSchedule)
|
2595
|
-
unitary_system.setSupplyFan(fan) unless fan.nil?
|
2596
|
-
unitary_system.setHeatingCoil(htg_coil) unless htg_coil.nil?
|
2597
|
-
unitary_system.setCoolingCoil(clg_coil) unless clg_coil.nil?
|
2598
|
-
unitary_system.setName("#{air_loop.name} Unitary System")
|
2599
|
-
unitary_system.setControllingZoneorThermostatLocation(zone)
|
2600
|
-
unitary_system.setFanPlacement(fan_location)
|
2601
|
-
unitary_system.setSupplyAirFanOperatingModeSchedule(model.alwaysOffDiscreteSchedule)
|
2602
|
-
unitary_system.addToNode(air_loop.supplyInletNode)
|
2603
|
-
end
|
2569
|
+
when 'ConstantVolume'
|
2570
|
+
fan = create_fan_by_name(model,
|
2571
|
+
'Packaged_RTU_SZ_AC_CAV_OnOff_Fan',
|
2572
|
+
fan_name: "#{air_loop.name} Fan")
|
2604
2573
|
else
|
2605
|
-
|
2606
|
-
|
2607
|
-
|
2608
|
-
|
2609
|
-
|
2610
|
-
|
2611
|
-
|
2612
|
-
|
2613
|
-
|
2614
|
-
|
2615
|
-
|
2616
|
-
|
2617
|
-
|
2618
|
-
|
2619
|
-
|
2620
|
-
|
2621
|
-
|
2622
|
-
|
2623
|
-
|
2624
|
-
|
2625
|
-
|
2626
|
-
|
2627
|
-
|
2628
|
-
|
2629
|
-
|
2630
|
-
|
2631
|
-
|
2632
|
-
|
2633
|
-
|
2634
|
-
|
2635
|
-
|
2636
|
-
|
2637
|
-
|
2638
|
-
|
2639
|
-
|
2640
|
-
|
2641
|
-
|
2642
|
-
|
2643
|
-
|
2644
|
-
|
2645
|
-
|
2646
|
-
|
2647
|
-
|
2648
|
-
|
2649
|
-
|
2650
|
-
|
2651
|
-
|
2652
|
-
|
2653
|
-
fan.addToNode(air_loop.supplyInletNode) unless fan.nil?
|
2654
|
-
else
|
2655
|
-
OpenStudio.logFree(OpenStudio::Error, 'openstudio.model.Model', 'Invalid fan location')
|
2656
|
-
return false
|
2657
|
-
end
|
2574
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.model.Model', 'Invalid fan_type')
|
2575
|
+
return false
|
2576
|
+
end
|
2577
|
+
|
2578
|
+
# fan location
|
2579
|
+
if fan_location.nil?
|
2580
|
+
fan_location = 'DrawThrough'
|
2581
|
+
end
|
2582
|
+
case fan_location
|
2583
|
+
when 'DrawThrough', 'BlowThrough'
|
2584
|
+
OpenStudio.logFree(OpenStudio::Debug, 'openstudio.Model.Model', "Setting fan location for #{fan.name} to #{fan_location}.")
|
2585
|
+
else
|
2586
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.model.Model', "Invalid fan_location #{fan_location} for fan #{fan.name}.")
|
2587
|
+
return false
|
2588
|
+
end
|
2589
|
+
|
2590
|
+
# construct unitary system object
|
2591
|
+
unitary_system = OpenStudio::Model::AirLoopHVACUnitarySystem.new(model)
|
2592
|
+
unitary_system.setSupplyFan(fan) unless fan.nil?
|
2593
|
+
unitary_system.setHeatingCoil(htg_coil) unless htg_coil.nil?
|
2594
|
+
unitary_system.setCoolingCoil(clg_coil) unless clg_coil.nil?
|
2595
|
+
unitary_system.setSupplementalHeatingCoil(supplemental_htg_coil) unless supplemental_htg_coil.nil?
|
2596
|
+
unitary_system.setControllingZoneorThermostatLocation(zone)
|
2597
|
+
unitary_system.setFanPlacement(fan_location)
|
2598
|
+
unitary_system.addToNode(air_loop.supplyInletNode)
|
2599
|
+
|
2600
|
+
# added logic and naming for heat pumps
|
2601
|
+
case heating_type
|
2602
|
+
when 'Water To Air Heat Pump'
|
2603
|
+
unitary_system.setMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation(OpenStudio.convert(40.0, 'F', 'C').get)
|
2604
|
+
unitary_system.setName("#{air_loop.name} Unitary HP")
|
2605
|
+
unitary_system.setMaximumSupplyAirTemperature(dsgn_temps['zn_htg_dsgn_sup_air_temp_c'])
|
2606
|
+
unitary_system.setSupplyAirFlowRateMethodDuringCoolingOperation('SupplyAirFlowRate')
|
2607
|
+
unitary_system.setSupplyAirFlowRateMethodDuringHeatingOperation('SupplyAirFlowRate')
|
2608
|
+
unitary_system.setSupplyAirFlowRateMethodWhenNoCoolingorHeatingisRequired('SupplyAirFlowRate')
|
2609
|
+
when 'Single Speed Heat Pump'
|
2610
|
+
unitary_system.setMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation(OpenStudio.convert(40.0, 'F', 'C').get)
|
2611
|
+
unitary_system.setName("#{air_loop.name} Unitary HP")
|
2612
|
+
else
|
2613
|
+
unitary_system.setName("#{air_loop.name} Unitary AC")
|
2614
|
+
end
|
2615
|
+
|
2616
|
+
# specify control logic
|
2617
|
+
unitary_system.setAvailabilitySchedule(hvac_op_sch)
|
2618
|
+
if fan_type == 'Cycling'
|
2619
|
+
unitary_system.setSupplyAirFanOperatingModeSchedule(model.alwaysOffDiscreteSchedule)
|
2620
|
+
else # constant volume operation
|
2621
|
+
unitary_system.setSupplyAirFanOperatingModeSchedule(hvac_op_sch)
|
2658
2622
|
end
|
2659
2623
|
|
2660
2624
|
# add the OA system
|
@@ -3033,7 +2997,6 @@ class Standard
|
|
3033
2997
|
return air_loops
|
3034
2998
|
end
|
3035
2999
|
|
3036
|
-
|
3037
3000
|
# Creates a CRAC system for data center and adds it to the model.
|
3038
3001
|
#
|
3039
3002
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
@@ -3159,7 +3122,7 @@ class Standard
|
|
3159
3122
|
# To solve the issue, add economizer here for cold climates
|
3160
3123
|
# select the climate zones with winter design temperature lower than -20C (for safer)
|
3161
3124
|
cold_climates = ['ASHRAE 169-2006-6A', 'ASHRAE 169-2006-6B', 'ASHRAE 169-2006-7A',
|
3162
|
-
|
3125
|
+
'ASHRAE 169-2006-7B', 'ASHRAE 169-2006-8A', 'ASHRAE 169-2006-8B']
|
3163
3126
|
if cold_climates.include? climate_zone
|
3164
3127
|
# Determine the economizer type in the prototype buildings, which depends on climate zone.
|
3165
3128
|
economizer_type = model_economizer_type(model, climate_zone)
|
@@ -3217,10 +3180,10 @@ class Standard
|
|
3217
3180
|
if supply_temp_sch.nil?
|
3218
3181
|
supply_temp_sch = model_add_constant_schedule_ruleset(model,
|
3219
3182
|
dsgn_temps['clg_dsgn_sup_air_temp_c'],
|
3220
|
-
name =
|
3183
|
+
name = 'AHU Supply Temp Sch')
|
3221
3184
|
end
|
3222
3185
|
setpoint_mgr_cooling = OpenStudio::Model::SetpointManagerScheduled.new(model, supply_temp_sch)
|
3223
|
-
setpoint_mgr_cooling.setName(
|
3186
|
+
setpoint_mgr_cooling.setName('CRAC supply air setpoint manager')
|
3224
3187
|
setpoint_mgr_cooling.addToNode(air_loop.supplyOutletNode)
|
3225
3188
|
|
3226
3189
|
# Add the OA system
|
@@ -3284,7 +3247,7 @@ class Standard
|
|
3284
3247
|
# air handler
|
3285
3248
|
air_loop = OpenStudio::Model::AirLoopHVAC.new(model)
|
3286
3249
|
if system_name.nil?
|
3287
|
-
air_loop.setName(
|
3250
|
+
air_loop.setName('Data Center CRAH')
|
3288
3251
|
else
|
3289
3252
|
air_loop.setName(system_name)
|
3290
3253
|
end
|
@@ -3313,10 +3276,10 @@ class Standard
|
|
3313
3276
|
if supply_temp_sch.nil?
|
3314
3277
|
supply_temp_sch = model_add_constant_schedule_ruleset(model,
|
3315
3278
|
dsgn_temps['clg_dsgn_sup_air_temp_c'],
|
3316
|
-
name =
|
3279
|
+
name = 'AHU Supply Temp Sch')
|
3317
3280
|
end
|
3318
3281
|
setpoint_mgr_cooling = OpenStudio::Model::SetpointManagerScheduled.new(model, supply_temp_sch)
|
3319
|
-
setpoint_mgr_cooling.setName(
|
3282
|
+
setpoint_mgr_cooling.setName('CRAH supply air setpoint manager')
|
3320
3283
|
setpoint_mgr_cooling.addToNode(air_loop.supplyOutletNode)
|
3321
3284
|
|
3322
3285
|
# create fan
|
@@ -3365,7 +3328,6 @@ class Standard
|
|
3365
3328
|
|
3366
3329
|
# hook the CRAH system to each zone
|
3367
3330
|
thermal_zones.each do |zone|
|
3368
|
-
|
3369
3331
|
# Create a diffuser and attach the zone/diffuser pair to the air loop
|
3370
3332
|
diffuser = OpenStudio::Model::AirTerminalSingleDuctVAVNoReheat.new(model, model.alwaysOnDiscreteSchedule)
|
3371
3333
|
diffuser.setName("#{zone.name} VAV terminal")
|
@@ -3395,7 +3357,6 @@ class Standard
|
|
3395
3357
|
return air_loop
|
3396
3358
|
end
|
3397
3359
|
|
3398
|
-
|
3399
3360
|
# Creates a split DX AC system for each zone and adds it to the model.
|
3400
3361
|
#
|
3401
3362
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
@@ -3419,7 +3380,7 @@ class Standard
|
|
3419
3380
|
|
3420
3381
|
# create a split AC for each group of thermal zones
|
3421
3382
|
air_loop = OpenStudio::Model::AirLoopHVAC.new(model)
|
3422
|
-
thermal_zones_name =
|
3383
|
+
thermal_zones_name = thermal_zones.map(&:name).join(' - ')
|
3423
3384
|
air_loop.setName("#{thermal_zones_name} SAC")
|
3424
3385
|
|
3425
3386
|
# hvac operation schedule
|
@@ -4108,20 +4069,20 @@ class Standard
|
|
4108
4069
|
# Create a sensor to read the zone load
|
4109
4070
|
zn_load_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model,
|
4110
4071
|
'Zone Predicted Sensible Load to Cooling Setpoint Heat Transfer Rate')
|
4111
|
-
zn_load_sensor.setName("#{zone_name_clean.to_s.gsub(/[ +-.]/,'_')} Clg Load Sensor")
|
4072
|
+
zn_load_sensor.setName("#{zone_name_clean.to_s.gsub(/[ +-.]/, '_')} Clg Load Sensor")
|
4112
4073
|
zn_load_sensor.setKeyName(zone.handle.to_s)
|
4113
4074
|
|
4114
4075
|
# Create an actuator to set the airloop availability
|
4115
4076
|
air_loop_avail_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(air_loop_avail_sch,
|
4116
4077
|
'Schedule:Constant',
|
4117
4078
|
'Schedule Value')
|
4118
|
-
air_loop_avail_actuator.setName("#{air_loop.name.to_s.gsub(/[ +-.]/,'_')} Availability Actuator")
|
4079
|
+
air_loop_avail_actuator.setName("#{air_loop.name.to_s.gsub(/[ +-.]/, '_')} Availability Actuator")
|
4119
4080
|
|
4120
4081
|
# Create a program to turn on Evap Cooler if
|
4121
4082
|
# there is a cooling load in the target zone.
|
4122
4083
|
# Load < 0.0 is a cooling load.
|
4123
4084
|
avail_program = OpenStudio::Model::EnergyManagementSystemProgram.new(model)
|
4124
|
-
avail_program.setName("#{air_loop.name.to_s.gsub(/[ +-.]/,'_')} Availability Control")
|
4085
|
+
avail_program.setName("#{air_loop.name.to_s.gsub(/[ +-.]/, '_')} Availability Control")
|
4125
4086
|
avail_program_body = <<-EMS
|
4126
4087
|
IF #{zn_load_sensor.handle} < 0.0
|
4127
4088
|
SET #{air_loop_avail_actuator.handle} = 1
|
@@ -4823,7 +4784,6 @@ class Standard
|
|
4823
4784
|
air_loop.setName("#{zone.name} #{equip_name}")
|
4824
4785
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.Model.Model', "Adding furnace AC for #{zone.name}.")
|
4825
4786
|
|
4826
|
-
|
4827
4787
|
# default design temperatures across all air loops
|
4828
4788
|
dsgn_temps = standard_design_sizing_temperatures
|
4829
4789
|
|
@@ -5278,7 +5238,7 @@ class Standard
|
|
5278
5238
|
if include_outdoor_air
|
5279
5239
|
# get the design specification outdoor air of the largest space in the zone
|
5280
5240
|
# TODO: create a new design specification outdoor air object that sums ventilation rates and schedules if multiple design specification outdoor air objects
|
5281
|
-
space_areas = zone.spaces.map
|
5241
|
+
space_areas = zone.spaces.map(&:floorArea)
|
5282
5242
|
largest_space = zone.spaces.select { |s| s.floorArea == space_areas.max }
|
5283
5243
|
largest_space = largest_space[0]
|
5284
5244
|
design_spec_oa = largest_space.designSpecificationOutdoorAir
|
@@ -5612,7 +5572,7 @@ class Standard
|
|
5612
5572
|
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.Model.Model', "No chillers were found on #{chilled_water_loop.name}; cannot add a non-integrated waterside economizer.")
|
5613
5573
|
heat_exchanger.setControlType('CoolingSetpointOnOff')
|
5614
5574
|
elsif chillers.size > 1
|
5615
|
-
chiller = chillers.
|
5575
|
+
chiller = chillers.min
|
5616
5576
|
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.Model.Model', "More than one chiller was found on #{chilled_water_loop.name}. EnergyPlus only allows a single chiller to be interlocked with the HX. Chiller #{chiller.name} was selected. Additional chillers will not be locked out during HX operation.")
|
5617
5577
|
else # 1 chiller
|
5618
5578
|
chiller = chillers[0]
|
@@ -5706,6 +5666,9 @@ class Standard
|
|
5706
5666
|
# HighTemperature (180F supply) or LowTemperature (120F supply)
|
5707
5667
|
def model_get_or_add_hot_water_loop(model, heat_fuel,
|
5708
5668
|
hot_water_loop_type: 'HighTemperature')
|
5669
|
+
if heat_fuel.nil?
|
5670
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.model.Model', 'Hot water loop fuel type is nil. Cannot add hot water loop.')
|
5671
|
+
end
|
5709
5672
|
make_new_hot_water_loop = true
|
5710
5673
|
hot_water_loop = nil
|
5711
5674
|
# retrieve the existing hot water loop or add a new one if not of the correct type
|
@@ -5821,6 +5784,15 @@ class Standard
|
|
5821
5784
|
zone_equipment_ventilation: true,
|
5822
5785
|
fan_coil_capacity_control_method: 'CyclingFan')
|
5823
5786
|
|
5787
|
+
# enforce defaults if fields are nil
|
5788
|
+
hot_water_loop_type = 'HighTemperature' if hot_water_loop_type.nil?
|
5789
|
+
chilled_water_loop_cooling_type = 'WaterCooled' if chilled_water_loop_cooling_type.nil?
|
5790
|
+
heat_pump_loop_cooling_type = 'EvaporativeFluidCooler' if heat_pump_loop_cooling_type.nil?
|
5791
|
+
air_loop_heating_type = 'Water' if air_loop_heating_type.nil?
|
5792
|
+
air_loop_cooling_type = 'Water' if air_loop_cooling_type.nil?
|
5793
|
+
zone_equipment_ventilation = true if zone_equipment_ventilation.nil?
|
5794
|
+
fan_coil_capacity_control_method = 'CyclingFan' if fan_coil_capacity_control_method.nil?
|
5795
|
+
|
5824
5796
|
# don't do anything if there are no zones
|
5825
5797
|
return true if zones.empty?
|
5826
5798
|
|
@@ -6252,6 +6224,8 @@ class Standard
|
|
6252
6224
|
when 'DOAS'
|
6253
6225
|
if air_loop_heating_type == 'Water'
|
6254
6226
|
case main_heat_fuel
|
6227
|
+
when nil
|
6228
|
+
hot_water_loop = nil
|
6255
6229
|
when 'AirSourceHeatPump'
|
6256
6230
|
hot_water_loop = model_get_or_add_hot_water_loop(model, main_heat_fuel,
|
6257
6231
|
hot_water_loop_type: 'LowTemperature')
|
@@ -6280,6 +6254,8 @@ class Standard
|
|
6280
6254
|
when 'DOAS with DCV'
|
6281
6255
|
if air_loop_heating_type == 'Water'
|
6282
6256
|
case main_heat_fuel
|
6257
|
+
when nil
|
6258
|
+
hot_water_loop = nil
|
6283
6259
|
when 'AirSourceHeatPump'
|
6284
6260
|
hot_water_loop = model_get_or_add_hot_water_loop(model, main_heat_fuel,
|
6285
6261
|
hot_water_loop_type: 'LowTemperature')
|
@@ -6307,6 +6283,8 @@ class Standard
|
|
6307
6283
|
when 'DOAS with Economizing'
|
6308
6284
|
if air_loop_heating_type == 'Water'
|
6309
6285
|
case main_heat_fuel
|
6286
|
+
when nil
|
6287
|
+
hot_water_loop = nil
|
6310
6288
|
when 'AirSourceHeatPump'
|
6311
6289
|
hot_water_loop = model_get_or_add_hot_water_loop(model, main_heat_fuel,
|
6312
6290
|
hot_water_loop_type: 'LowTemperature')
|
data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb
CHANGED
@@ -25,8 +25,14 @@ class Standard
|
|
25
25
|
|
26
26
|
zone_name = zone.name.to_s.gsub(/[ +-.]/, '_')
|
27
27
|
zone_timestep = model.getTimestep.numberOfTimestepsPerHour
|
28
|
-
|
29
|
-
|
28
|
+
|
29
|
+
if model.version < OpenStudio::VersionString.new('3.1.1')
|
30
|
+
coil_cooling_radiant = radiant_loop.coolingCoil.to_CoilCoolingLowTempRadiantVarFlow.get
|
31
|
+
coil_heating_radiant = radiant_loop.heatingCoil.to_CoilHeatingLowTempRadiantVarFlow.get
|
32
|
+
else
|
33
|
+
coil_cooling_radiant = radiant_loop.coolingCoil.get.to_CoilCoolingLowTempRadiantVarFlow.get
|
34
|
+
coil_heating_radiant = radiant_loop.heatingCoil.get.to_CoilHeatingLowTempRadiantVarFlow.get
|
35
|
+
end
|
30
36
|
|
31
37
|
#####
|
32
38
|
# List of schedule objects used to hold calculation results
|
@@ -311,7 +317,7 @@ class Standard
|
|
311
317
|
OpenStudio.logFree(OpenStudio::Error, 'openstudio.Model.Model', "Zone #{zone.name} does not have floor surfaces; cannot add radiant system.")
|
312
318
|
return false
|
313
319
|
end
|
314
|
-
zone_floor = surfaces.
|
320
|
+
zone_floor = surfaces.max_by(&:grossArea)
|
315
321
|
zone_srf_temp = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Surface Inside Face Temperature')
|
316
322
|
zone_srf_temp.setName("#{zone_name}_Srf_Temp")
|
317
323
|
zone_srf_temp.setKeyName(zone_floor.name.get)
|