openstudio-standards 0.2.12 → 0.2.13.rc3

Sign up to get free protection for your applications and to get access to all the features.
Files changed (492) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAE90120162019HighriseApartment.json +1042 -0
  3. data/data/geometry/ASHRAE90120162019Hospital.json +199 -0
  4. data/data/geometry/ASHRAE90120162019LargeHotel.json +73 -0
  5. data/data/geometry/ASHRAE90120162019LargeOffice.json +109 -0
  6. data/data/geometry/ASHRAE90120162019SecondarySchool.json +205 -0
  7. data/data/geometry/ASHRAECourthouse.json +112 -0
  8. data/data/geometry/ASHRAECourthouse.osm +26470 -0
  9. data/data/geometry/ASHRAELargeHotel.osm +11 -1
  10. data/data/geometry/ASHRAELargeOffice.json +4 -0
  11. data/data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx +0 -0
  12. data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
  13. data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
  14. data/data/standards/exclude_list.csv +19 -0
  15. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +49 -0
  16. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +293 -0
  17. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +25426 -0
  18. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +1600 -0
  19. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +564 -0
  20. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +349 -0
  21. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +164 -0
  22. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +10663 -0
  23. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +508 -0
  24. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +156 -0
  25. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +44 -0
  26. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +184 -0
  27. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +3094 -0
  28. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +829 -0
  29. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +562 -0
  30. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +52 -0
  31. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +220 -0
  32. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +156 -0
  33. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +1316 -0
  34. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +21446 -0
  35. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +554 -0
  36. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +68 -0
  37. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +28 -0
  38. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +12 -0
  39. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +49 -0
  40. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +293 -0
  41. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +12487 -0
  42. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +1600 -0
  43. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +564 -0
  44. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +349 -0
  45. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +164 -0
  46. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +10663 -0
  47. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +466 -0
  48. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +137 -0
  49. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +44 -0
  50. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +184 -0
  51. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +3094 -0
  52. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +829 -0
  53. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +562 -0
  54. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +52 -0
  55. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +220 -0
  56. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +156 -0
  57. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +1316 -0
  58. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +21380 -0
  59. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +554 -0
  60. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +68 -0
  61. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +28 -0
  62. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +12 -0
  63. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +49 -0
  64. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +395 -0
  65. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +12487 -0
  66. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +1600 -0
  67. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +592 -0
  68. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +349 -0
  69. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +550 -0
  70. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +164 -0
  71. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +10663 -0
  72. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +466 -0
  73. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +137 -0
  74. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +44 -0
  75. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +238 -0
  76. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +3094 -0
  77. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +829 -0
  78. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +562 -0
  79. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +52 -0
  80. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +220 -0
  81. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +156 -0
  82. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +1316 -0
  83. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +21548 -0
  84. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +554 -0
  85. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +68 -0
  86. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +28 -0
  87. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +12 -0
  88. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +64 -0
  89. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +871 -0
  90. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +12487 -0
  91. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +1600 -0
  92. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +592 -0
  93. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +349 -0
  94. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +1096 -0
  95. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +164 -0
  96. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +10663 -0
  97. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +886 -0
  98. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +194 -0
  99. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +44 -0
  100. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +247 -0
  101. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +3094 -0
  102. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +829 -0
  103. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +562 -0
  104. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +52 -0
  105. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +220 -0
  106. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +156 -0
  107. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +1316 -0
  108. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +22079 -0
  109. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +994 -0
  110. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +68 -0
  111. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +28 -0
  112. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +12 -0
  113. data/data/standards/manage_OpenStudio_Standards.rb +87 -37
  114. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1-ALL-comstockspace_types.csv +236 -0
  115. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +622 -0
  116. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1space_types.csv +191 -0
  117. data/data/standards/openstudio_standards_duplicates_log.csv +16 -25
  118. data/data/standards/test_performance_expected_dd_results.csv +1934 -1134
  119. data/lib/openstudio-standards.rb +68 -17
  120. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +28 -0
  121. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +0 -1
  122. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +28 -0
  123. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +53 -2
  124. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +29 -0
  125. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +157 -2
  126. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +29 -0
  127. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
  128. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +32 -0
  129. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +33 -0
  130. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +32 -0
  131. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +25 -0
  132. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +366 -0
  133. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +144 -0
  134. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +11 -0
  135. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
  136. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +32 -0
  137. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +33 -0
  138. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +32 -0
  139. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +25 -0
  140. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +367 -0
  141. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +144 -0
  142. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +11 -0
  143. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +0 -1
  144. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +0 -1
  145. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
  146. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
  147. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
  148. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
  149. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +3 -3
  150. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +74 -0
  151. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +46 -30
  152. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +15 -7
  153. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +26 -15
  154. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +8 -11
  155. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +54 -60
  156. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +56 -60
  157. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +38 -12
  158. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +218 -134
  159. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +6 -2
  160. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +222 -133
  161. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +60 -62
  162. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +25 -15
  163. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +34 -22
  164. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +31 -7
  165. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +43 -28
  166. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +48 -38
  167. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +9 -5
  168. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +567 -344
  169. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +13 -19
  170. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +13 -17
  171. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +9 -5
  172. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +79 -51
  173. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +60 -60
  174. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +2 -4
  175. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +133 -120
  176. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +124 -112
  177. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +138 -66
  178. data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +7275 -199
  179. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +35 -35
  180. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -2
  181. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -2
  182. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +3 -3
  183. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +1 -1
  184. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +2 -2
  185. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +2 -2
  186. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
  187. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +2 -2
  188. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +2 -2
  189. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
  190. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
  191. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +4 -3
  192. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +7 -8
  193. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +7 -8
  194. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +13 -14
  195. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +7 -5
  196. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +2 -0
  197. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +0 -1
  198. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +25 -14
  199. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +474 -89
  200. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +35 -33
  201. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +3 -0
  202. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +72 -0
  203. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +120 -120
  204. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +103 -125
  205. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +9 -3
  206. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +11 -5
  207. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +26 -14
  208. data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +270 -247
  209. data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
  210. data/lib/openstudio-standards/refs/references.rb +5 -2
  211. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +41 -28
  212. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -1
  213. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +0 -1
  214. data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +1 -0
  215. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +2 -4
  216. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +8 -10
  217. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -5
  218. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +0 -1
  219. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
  220. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +12 -9
  221. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -1
  222. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +3 -1
  223. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +0 -3
  224. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +4 -7
  225. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -3
  226. data/lib/openstudio-standards/standards/Standards.Construction.rb +124 -118
  227. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +0 -1
  228. data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +0 -1
  229. data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +0 -1
  230. data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +0 -1
  231. data/lib/openstudio-standards/standards/Standards.Fan.rb +0 -1
  232. data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -1
  233. data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -1
  234. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -4
  235. data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -1
  236. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +10 -3
  237. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -1
  238. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -1
  239. data/lib/openstudio-standards/standards/Standards.Model.rb +282 -253
  240. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -0
  241. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -9
  242. data/lib/openstudio-standards/standards/Standards.Pump.rb +0 -1
  243. data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -1
  244. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +0 -1
  245. data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +0 -1
  246. data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +0 -1
  247. data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +103 -121
  248. data/lib/openstudio-standards/standards/Standards.Space.rb +42 -35
  249. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +9 -17
  250. data/lib/openstudio-standards/standards/Standards.SubSurface.rb +25 -27
  251. data/lib/openstudio-standards/standards/Standards.Surface.rb +97 -52
  252. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +39 -21
  253. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +6 -7
  254. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +15 -10
  255. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +0 -1
  256. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +10 -2
  257. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model.rb +2 -2
  258. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +63 -99
  259. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +7 -7
  260. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +2420 -0
  261. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +32 -0
  262. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +9 -0
  263. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +68 -38
  264. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +105 -40
  265. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +5 -1
  266. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +63 -99
  267. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +7 -7
  268. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +1460 -0
  269. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +32 -0
  270. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +9 -0
  271. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +68 -38
  272. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +104 -17
  273. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +25 -13
  274. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +1 -1
  275. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +63 -99
  276. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +7 -7
  277. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +1460 -0
  278. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +64 -0
  279. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +52 -0
  280. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +9 -0
  281. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +68 -38
  282. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +112 -25
  283. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +21 -7
  284. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
  285. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +63 -99
  286. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +7 -7
  287. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +1 -1
  288. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +2 -2
  289. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +1460 -0
  290. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +64 -0
  291. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +104 -0
  292. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +9 -0
  293. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +70 -40
  294. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +172 -55
  295. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +4 -4
  296. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +1 -1
  297. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +456 -0
  298. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
  299. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +19 -0
  300. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerSingleSpeed.rb +5 -0
  301. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerTwoSpeed.rb +5 -0
  302. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +16 -0
  303. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +37 -0
  304. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +189 -0
  305. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +57 -0
  306. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +22 -0
  307. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +16 -0
  308. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.boilers.json +68 -0
  309. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.chillers.json +490 -0
  310. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_properties.json +21244 -0
  311. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_sets.json +2111 -0
  312. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.economizers.json +676 -0
  313. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.elevators.json +372 -0
  314. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +1096 -0
  315. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ext_ltg.json +169 -0
  316. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +532 -0
  317. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +164 -0
  318. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_rejection.json +49 -0
  319. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.motors.json +274 -0
  320. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.prototype_inputs.json +3094 -0
  321. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_cases.json +854 -0
  322. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_lnup.json +562 -0
  323. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_compressors.json +58 -0
  324. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_condenser.json +238 -0
  325. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_system.json +12 -0
  326. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_walkins.json +1316 -0
  327. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +23067 -0
  328. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +648 -0
  329. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +72 -0
  330. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps.json +31 -0
  331. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps_heating.json +13 -0
  332. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +456 -0
  333. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
  334. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +19 -0
  335. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerSingleSpeed.rb +5 -0
  336. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerTwoSpeed.rb +5 -0
  337. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +16 -0
  338. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +37 -0
  339. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +189 -0
  340. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +57 -0
  341. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +22 -0
  342. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +16 -0
  343. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +68 -0
  344. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.chillers.json +490 -0
  345. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_properties.json +21244 -0
  346. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_sets.json +2111 -0
  347. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.economizers.json +676 -0
  348. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.elevators.json +372 -0
  349. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +1096 -0
  350. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ext_ltg.json +169 -0
  351. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +664 -0
  352. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +204 -0
  353. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_rejection.json +49 -0
  354. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.motors.json +274 -0
  355. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.prototype_inputs.json +3094 -0
  356. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_cases.json +854 -0
  357. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_lnup.json +562 -0
  358. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +58 -0
  359. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_condenser.json +238 -0
  360. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_system.json +12 -0
  361. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_walkins.json +1316 -0
  362. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +23067 -0
  363. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +671 -0
  364. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +72 -0
  365. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps.json +31 -0
  366. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps_heating.json +13 -0
  367. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +1662 -332
  368. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.materials.json +5049 -289
  369. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +1743 -161
  370. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +63 -99
  371. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +11 -11
  372. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.heat_rejection.json +9 -0
  373. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +8 -8
  374. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +9 -9
  375. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +4 -4
  376. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +63 -99
  377. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ext_ltg.json +10 -10
  378. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.heat_rejection.json +9 -0
  379. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +7 -7
  380. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +9 -9
  381. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +4 -4
  382. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_rejection.json +9 -0
  383. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +0 -1
  384. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +4 -4
  385. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
  386. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +1 -1
  387. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json +9 -0
  388. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json +2 -2
  389. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +3 -6
  390. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +4 -4
  391. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
  392. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +1 -1
  393. data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -3
  394. data/lib/openstudio-standards/standards/cbes/cbes.rb +1 -1
  395. data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +8 -13
  396. data/lib/openstudio-standards/standards/deer/deer.Model.rb +2 -2
  397. data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +2 -0
  398. data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
  399. data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +0 -1
  400. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +0 -1
  401. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +0 -1
  402. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +0 -1
  403. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +0 -1
  404. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +1 -1
  405. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
  406. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +0 -1
  407. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +1 -1
  408. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
  409. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +0 -1
  410. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +1 -1
  411. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
  412. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +0 -1
  413. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +1 -1
  414. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
  415. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +0 -1
  416. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +1 -1
  417. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
  418. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +0 -1
  419. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +1 -1
  420. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
  421. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +0 -1
  422. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +1 -1
  423. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
  424. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +0 -1
  425. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +1 -1
  426. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
  427. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +0 -1
  428. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +1 -1
  429. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
  430. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +0 -1
  431. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +1 -1
  432. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
  433. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +0 -1
  434. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +1 -1
  435. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
  436. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +0 -1
  437. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +1 -1
  438. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
  439. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +0 -1
  440. data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +0 -1
  441. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +28 -7
  442. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +16 -2
  443. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +15 -0
  444. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +14 -0
  445. data/lib/openstudio-standards/standards/necb/ECMS/data/erv.json +11 -7
  446. data/lib/openstudio-standards/standards/necb/ECMS/data/pv.json +112 -0
  447. data/lib/openstudio-standards/standards/necb/ECMS/data/unitary_acs.json +50 -0
  448. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +21 -8
  449. data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +17 -6
  450. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +142 -6
  451. data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +189 -0
  452. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +104 -0
  453. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +19 -13
  454. data/lib/openstudio-standards/standards/necb/NECB2011/data/erv.json +1 -1
  455. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +39278 -0
  456. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +17 -1
  457. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +15 -0
  458. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +14 -2
  459. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +13 -0
  460. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +12 -0
  461. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +154 -12
  462. data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +21 -3
  463. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +140 -21
  464. data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +74 -0
  465. data/lib/openstudio-standards/standards/necb/NECB2011/pv_ground.md +44 -0
  466. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +2 -2
  467. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/qaqc_resources/neb_end_use_prices.csv +39 -84
  468. data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +0 -1
  469. data/lib/openstudio-standards/standards/standard.rb +6 -5
  470. data/lib/openstudio-standards/utilities/Add_template_field_to_json.rb +3 -3
  471. data/lib/openstudio-standards/utilities/convert_surfaces_to_adiabatic_necb_8426.rb +54 -54
  472. data/lib/openstudio-standards/utilities/generate_prototype_database.rb +2 -2
  473. data/lib/openstudio-standards/utilities/generate_space_types.rb +3 -3
  474. data/lib/openstudio-standards/utilities/logging.rb +7 -7
  475. data/lib/openstudio-standards/utilities/necb_to_epw_map.rb +14 -14
  476. data/lib/openstudio-standards/utilities/os_sim_extract.rb +25 -25
  477. data/lib/openstudio-standards/utilities/rename_surfaces.rb +10 -13
  478. data/lib/openstudio-standards/utilities/round_surf_coords.rb +18 -20
  479. data/lib/openstudio-standards/utilities/sched_create.rb +39 -41
  480. data/lib/openstudio-standards/utilities/set_mult_to_adiabatic.rb +31 -31
  481. data/lib/openstudio-standards/utilities/simulation.rb +5 -3
  482. data/lib/openstudio-standards/utilities/speacetype_map_converter.rb +10 -11
  483. data/lib/openstudio-standards/utilities/sqlfile.rb +6 -8
  484. data/lib/openstudio-standards/utilities/template_measure/measure.rb +108 -0
  485. data/lib/openstudio-standards/utilities/template_measure/measure.xml +162 -0
  486. data/lib/openstudio-standards/utilities/template_measure/resources/BTAPMeasureHelper.rb +448 -0
  487. data/lib/openstudio-standards/utilities/template_measure/tests/test.rb +160 -0
  488. data/lib/openstudio-standards/utilities/weatherData1_xlsx_to_json.rb +23 -26
  489. data/lib/openstudio-standards/version.rb +1 -1
  490. data/lib/openstudio-standards/weather/Weather.Model.rb +74 -80
  491. data/lib/openstudio-standards/weather/Weather.stat_file.rb +17 -17
  492. metadata +217 -2
@@ -0,0 +1,24 @@
1
+ class ASHRAE9012019 < ASHRAE901
2
+ # @!group AirTerminalSingleDuctVAVReheat
3
+
4
+ # Specifies the minimum damper position for VAV dampers.
5
+ # For terminals with hot water heat and DDC, the minimum is 20%,
6
+ # otherwise the minimum is 30%.
7
+ #
8
+ # @param has_ddc [Bool] whether or not there is DDC control of the VAV terminal in question
9
+ def air_terminal_single_duct_vav_reheat_minimum_damper_position(air_terminal_single_duct_vav_reheat, has_ddc = false)
10
+ min_damper_position = nil
11
+ case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
12
+ when 'HotWater'
13
+ min_damper_position = if has_ddc
14
+ 0.2
15
+ else
16
+ 0.3
17
+ end
18
+ when 'Electricity', 'NaturalGas'
19
+ min_damper_position = 0.3
20
+ end
21
+
22
+ return min_damper_position
23
+ end
24
+ end
@@ -0,0 +1,19 @@
1
+ # A variety of cooling tower methods that are the same regardless of type.
2
+ # These methods are available to CoolingTowerSingleSpeed, CoolingTowerTwoSpeed, and CoolingTowerVariableSpeed
3
+ module ASHRAE9012019CoolingTower
4
+ # @!group CoolingTower
5
+
6
+ # Above this point, centrifugal fan cooling towers must meet the limits
7
+ # of propeller or axial cooling towers instead.
8
+ # 90.1 6.5.5.3 Limit on Centrifugal Fan Open Circuit Cooling Towers.
9
+ # is 1,100 gallons per minute.
10
+ #
11
+ # @param cooling_tower [OpenStudio::Model::CoolingTowerSingleSpeed,
12
+ # OpenStudio::Model::CoolingTowerTwoSpeed,
13
+ # OpenStudio::Model::CoolingTowerVariableSpeed] the cooling tower
14
+ # @return [Double] the limit, in gallons per minute. Return nil for no limit.
15
+ def cooling_tower_apply_minimum_power_per_flow_gpm_limit(cooling_tower)
16
+ gpm_limit = 1100
17
+ return gpm_limit
18
+ end
19
+ end
@@ -0,0 +1,5 @@
1
+ class ASHRAE9012019 < ASHRAE901
2
+ # @!group CoolingTowerSingleSpeed
3
+
4
+ include ASHRAE9012019CoolingTower
5
+ end
@@ -0,0 +1,5 @@
1
+ class ASHRAE9012019 < ASHRAE901
2
+ # @!group CoolingTowerTwoSpeed
3
+
4
+ include ASHRAE9012019CoolingTower
5
+ end
@@ -0,0 +1,16 @@
1
+ class ASHRAE9012019 < ASHRAE901
2
+ # @!group CoolingTowerVariableSpeed
3
+
4
+ include ASHRAE9012019CoolingTower
5
+
6
+ # Apply the efficiency, plus Multicell heat rejection with VSD
7
+ #
8
+ # @param cooling_tower_variable_speed [OpenStudio::Model::CoolingTowerVariableSpeed] the cooling tower
9
+ def cooling_tower_variable_speed_apply_efficiency_and_curves(cooling_tower_variable_speed)
10
+ cooling_tower_apply_minimum_power_per_flow(cooling_tower_variable_speed)
11
+
12
+ cooling_tower_variable_speed.setCellControl('MaximalCell')
13
+
14
+ return true
15
+ end
16
+ end
@@ -0,0 +1,37 @@
1
+ class ASHRAE9012019 < ASHRAE901
2
+ # @!group FanVariableVolume
3
+
4
+ # The threhold horsepower below which part load control is not required.
5
+ # Per 90.1-2019, table 6.5.3.2.1: the fan motor size for chiller-water
6
+ # and evaporative cooling is 0.25 hp as of 1/1/2014 instead of 5 hp
7
+ #
8
+ # @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] the fan
9
+ # @return [Double] the limit, in horsepower. Return nil for no limit by default.
10
+ def fan_variable_volume_part_load_fan_power_limitation_hp_limit(fan_variable_volume)
11
+ hp_limit = case fan_variable_volume_cooling_system_type(fan_variable_volume)
12
+ when 'dx'
13
+ 0.0
14
+ when 'chw'
15
+ 0.25
16
+ when 'evap'
17
+ 0.25
18
+ end
19
+
20
+ return hp_limit
21
+ end
22
+
23
+ # The threhold capacity below which part load control is not required.
24
+ # Per 90.1-2019, table 6.5.3.2.1: the cooling capacity threshold is 75000
25
+ # instead of 110000 as of 1/1/2014
26
+ #
27
+ # @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] the fan
28
+ # @return [Double] the limit, in Btu/hr. Return nil for no limit by default.
29
+ def fan_variable_volume_part_load_fan_power_limitation_capacity_limit(fan_variable_volume)
30
+ cap_limit_btu_per_hr = case fan_variable_volume_cooling_system_type(fan_variable_volume)
31
+ when 'dx'
32
+ 65_000
33
+ end
34
+
35
+ return cap_limit_btu_per_hr
36
+ end
37
+ end
@@ -0,0 +1,189 @@
1
+ class ASHRAE9012019 < ASHRAE901
2
+ # @!group Space
3
+
4
+ # Determines the method used to extend the daylighted area horizontally
5
+ # next to a window. If the method is 'fixed', 2 ft is added to the
6
+ # width of each window. If the method is 'proportional', a distance
7
+ # equal to half of the head height of the window is added. If the method is 'none',
8
+ # no additional width is added.
9
+ #
10
+ # @return [String] returns 'fixed' or 'proportional'
11
+ def space_daylighted_area_window_width(space)
12
+ method = 'proportional'
13
+ return method
14
+ end
15
+
16
+ # Determine if the space requires daylighting controls for
17
+ # toplighting, primary sidelighting, and secondary sidelighting.
18
+ # Defaults to false for all types.
19
+ #
20
+ # @param space [OpenStudio::Model::Space] the space in question
21
+ # @param areas [Hash] a hash of daylighted areas
22
+ # @return [Array<Bool>] req_top_ctrl, req_pri_ctrl, req_sec_ctrl
23
+ def space_daylighting_control_required?(space, areas)
24
+ req_top_ctrl = true
25
+ req_pri_ctrl = true
26
+ req_sec_ctrl = true
27
+
28
+ # Get the LPD of the space
29
+ space_lpd_w_per_m2 = space.lightingPowerPerFloorArea
30
+
31
+ # Primary Sidelighting
32
+ # Check if the primary sidelit area contains less than 150W of lighting
33
+ if areas['primary_sidelighted_area'] == 0.0
34
+ OpenStudio.logFree(OpenStudio::Debug, 'openstudio.model.Space', "For #{space.name}, primary sidelighting control not required because primary sidelighted area = 0ft2 per 9.4.1.1(e).")
35
+ req_pri_ctrl = false
36
+ elsif areas['primary_sidelighted_area'] * space_lpd_w_per_m2 < 150.0
37
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Space', "For #{space.name}, primary sidelighting control not required because less than 150W of lighting are present in the primary daylighted area per 9.4.1.1(e).")
38
+ req_pri_ctrl = false
39
+ else
40
+ # Check the size of the windows
41
+ if areas['total_window_area'] < OpenStudio.convert(20.0, 'ft^2', 'm^2').get
42
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Space', "For #{space.name}, primary sidelighting control not required because there are less than 20ft2 of window per 9.4.1.1(e) Exception 2.")
43
+ req_pri_ctrl = false
44
+ end
45
+ end
46
+
47
+ # Secondary Sidelighting
48
+ # Check if the primary and secondary sidelit areas contains less than 300W of lighting
49
+ if areas['secondary_sidelighted_area'] == 0.0
50
+ OpenStudio.logFree(OpenStudio::Debug, 'openstudio.model.Space', "For #{space.name}, secondary sidelighting control not required because secondary sidelighted area = 0ft2 per 9.4.1.1(e).")
51
+ req_sec_ctrl = false
52
+ elsif (areas['primary_sidelighted_area'] + areas['secondary_sidelighted_area']) * space_lpd_w_per_m2 < 300
53
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Space', "For #{space.name}, secondary sidelighting control not required because less than 300W of lighting are present in the combined primary and secondary daylighted areas per 9.4.1.1(e).")
54
+ req_sec_ctrl = false
55
+ else
56
+ # Check the size of the windows
57
+ if areas['total_window_area'] < OpenStudio.convert(20.0, 'ft^2', 'm^2').get
58
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Space', "For #{space.name}, secondary sidelighting control not required because there are less than 20ft2 of window per 9.4.1.1(e) Exception 2.")
59
+ req_sec_ctrl = false
60
+ end
61
+ end
62
+
63
+ # Toplighting
64
+ # Check if the toplit area contains less than 150W of lighting
65
+ if areas['toplighted_area'] == 0.0
66
+ OpenStudio.logFree(OpenStudio::Debug, 'openstudio.model.Space', "For #{space.name}, toplighting control not required because toplighted area = 0ft2 per 9.4.1.1(f).")
67
+ req_top_ctrl = false
68
+ elsif areas['toplighted_area'] * space_lpd_w_per_m2 < 150
69
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Space', "For #{space.name}, toplighting control not required because less than 150W of lighting are present in the toplighted area per 9.4.1.1(f).")
70
+ req_top_ctrl = false
71
+ end
72
+
73
+ # Exceptions
74
+ if space.spaceType.is_initialized
75
+ case space.spaceType.get.standardsSpaceType.to_s
76
+ # Retail spaces exception (c) to Section 9.4.1.4
77
+ # req_sec_ctrl set to true to create a second reference point
78
+ when 'Core_Retail'
79
+ req_pri_ctrl = false
80
+ req_sec_ctrl = true
81
+ when 'Entry', 'Front_Retail', 'Point_of_Sale'
82
+ req_pri_ctrl = false
83
+ req_sec_ctrl = false
84
+ # Strip mall
85
+ when 'Strip mall - type 1', 'Strip mall - type 2', 'Strip mall - type 3'
86
+ req_pri_ctrl = false
87
+ req_sec_ctrl = false
88
+ # Residential apartments
89
+ when 'Apartment', 'Apartment_topfloor_NS', 'Apartment_topfloor_WE'
90
+ req_top_ctrl = false
91
+ req_pri_ctrl = false
92
+ req_sec_ctrl = false
93
+ end
94
+ end
95
+
96
+ return [req_top_ctrl, req_pri_ctrl, req_sec_ctrl]
97
+ end
98
+
99
+ # Determine the fraction controlled by each sensor and which
100
+ # window each sensor should go near.
101
+ #
102
+ # @param space [OpenStudio::Model::Space] the space with the daylighting
103
+ # @param sorted_windows [Hash] a hash of windows, sorted by priority
104
+ # @param sorted_skylights [Hash] a hash of skylights, sorted by priority
105
+ # @param req_top_ctrl [Bool] if toplighting controls are required
106
+ # @param req_pri_ctrl [Bool] if primary sidelighting controls are required
107
+ # @param req_sec_ctrl [Bool] if secondary sidelighting controls are required
108
+ def space_daylighting_fractions_and_windows(space,
109
+ areas,
110
+ sorted_windows,
111
+ sorted_skylights,
112
+ req_top_ctrl,
113
+ req_pri_ctrl,
114
+ req_sec_ctrl)
115
+ sensor_1_frac = 0.0
116
+ sensor_2_frac = 0.0
117
+ sensor_1_window = nil
118
+ sensor_2_window = nil
119
+
120
+ # Get the area of the space
121
+ space_area_m2 = space.floorArea
122
+
123
+ # get the climate zone
124
+ climate_zone = model_standards_climate_zone(space.model)
125
+
126
+ if req_top_ctrl && req_pri_ctrl && req_sec_ctrl
127
+ # Sensor 1 controls toplighted area
128
+ sensor_1_frac = areas['toplighted_area'] / space_area_m2
129
+ sensor_1_window = sorted_skylights[0]
130
+ # Sensor 2 controls primary + secondary area
131
+ sensor_2_frac = (areas['primary_sidelighted_area'] + areas['secondary_sidelighted_area']) / space_area_m2
132
+ sensor_2_window = sorted_windows[0]
133
+ elsif !req_top_ctrl && req_pri_ctrl && req_sec_ctrl
134
+ # Sensor 1 controls primary area
135
+ sensor_1_frac = areas['primary_sidelighted_area'] / space_area_m2
136
+ sensor_1_window = sorted_windows[0]
137
+ # Sensor 2 controls secondary area
138
+ sensor_2_frac = (areas['secondary_sidelighted_area'] / space_area_m2)
139
+ sensor_2_window = sorted_windows[0]
140
+ elsif req_top_ctrl && !req_pri_ctrl && req_sec_ctrl
141
+ # Sensor 1 controls toplighted area
142
+ sensor_1_frac = areas['toplighted_area'] / space_area_m2
143
+ sensor_1_window = sorted_skylights[0]
144
+ # Sensor 2 controls secondary area
145
+ sensor_2_frac = (areas['secondary_sidelighted_area'] / space_area_m2)
146
+ # sorted_skylights[0] assigned to sensor_2_window so a second reference point is added for top daylighting
147
+ sensor_2_window = sorted_skylights[0]
148
+ elsif req_top_ctrl && !req_pri_ctrl && !req_sec_ctrl
149
+ case climate_zone
150
+ when 'ASHRAE 169-2006-6A',
151
+ 'ASHRAE 169-2006-6B',
152
+ 'ASHRAE 169-2006-7A',
153
+ 'ASHRAE 169-2006-8A',
154
+ 'ASHRAE 169-2013-6A',
155
+ 'ASHRAE 169-2013-6B',
156
+ 'ASHRAE 169-2013-7A',
157
+ 'ASHRAE 169-2013-8A'
158
+ # Sensor 1 controls toplighted area
159
+ sensor_1_frac = areas['toplighted_area'] / space_area_m2
160
+ sensor_1_window = sorted_skylights[0]
161
+ else
162
+ # Sensor 1 controls toplighted area
163
+ sensor_1_frac = areas['toplighted_area'] / space_area_m2
164
+ sensor_1_window = sorted_skylights[0]
165
+ sensor_2_frac = sensor_1_frac
166
+ sensor_2_window = sensor_1_window
167
+ end
168
+ elsif !req_top_ctrl && req_pri_ctrl && !req_sec_ctrl
169
+ # Sensor 1 controls primary area
170
+ sensor_1_frac = areas['primary_sidelighted_area'] / space_area_m2
171
+ sensor_1_window = sorted_windows[0]
172
+ elsif !req_top_ctrl && !req_pri_ctrl && req_sec_ctrl
173
+ # Sensor 1 controls secondary area
174
+ sensor_1_frac = areas['secondary_sidelighted_area'] / space_area_m2
175
+ sensor_1_window = sorted_windows[0]
176
+ end
177
+
178
+ return [sensor_1_frac, sensor_2_frac, sensor_1_window, sensor_2_window]
179
+ end
180
+
181
+ # Determine the base infiltration rate at 75 PA.
182
+ #
183
+ # @return [Double] the baseline infiltration rate, in cfm/ft^2
184
+ # defaults to no infiltration.
185
+ def space_infiltration_rate_75_pa(space)
186
+ basic_infil_rate_cfm_per_ft2 = 1.0
187
+ return basic_infil_rate_cfm_per_ft2
188
+ end
189
+ end
@@ -0,0 +1,57 @@
1
+ class ASHRAE9012019 < ASHRAE901
2
+ # @!group ThermalZone
3
+
4
+ # Determine the thermal zone's occupancy type category.
5
+ # Options are: residential, nonresidential, publicassembly, retail
6
+ #
7
+ # @return [String] the occupancy type category
8
+ # @todo Add public assembly building types
9
+ def thermal_zone_occupancy_type(thermal_zone)
10
+ occ_type = if thermal_zone_residential?(thermal_zone)
11
+ 'residential'
12
+ else
13
+ 'nonresidential'
14
+ end
15
+
16
+ # Based on the space type that
17
+ # represents a majority of the zone.
18
+ space_type = thermal_zone_majority_space_type(thermal_zone)
19
+ if space_type.is_initialized
20
+ space_type = space_type.get
21
+ bldg_type = space_type.standardsBuildingType
22
+ if bldg_type.is_initialized
23
+ bldg_type = bldg_type.get
24
+ case bldg_type
25
+ when 'Retail', 'StripMall', 'SuperMarket'
26
+ occ_type = 'retail'
27
+ # when 'SomeBuildingType' # TODO add publicassembly building types
28
+ # occ_type = 'publicassembly'
29
+ end
30
+ end
31
+ end
32
+
33
+ # OpenStudio::logFree(OpenStudio::Info, "openstudio.Standards.ThermalZone", "For #{self.name}, occupancy type = #{occ_type}.")
34
+
35
+ return occ_type
36
+ end
37
+
38
+ # Determine the area and occupancy level limits for
39
+ # demand control ventilation.
40
+ #
41
+ # @param thermal_zone [OpenStudio::Model::ThermalZone] the thermal zone
42
+ # @return [Array<Double>] the minimum area, in m^2
43
+ # and the minimum occupancy density in m^2/person. Returns nil
44
+ # if there is no requirement.
45
+ def thermal_zone_demand_control_ventilation_limits(thermal_zone)
46
+ min_area_ft2 = 500
47
+ min_occ_per_1000_ft2 = 25
48
+
49
+ # Convert to SI
50
+ min_area_m2 = OpenStudio.convert(min_area_ft2, 'ft^2', 'm^2').get
51
+ min_occ_per_ft2 = min_occ_per_1000_ft2 / 1000.0
52
+ min_ft2_per_occ = 1.0 / min_occ_per_ft2
53
+ min_m2_per_occ = OpenStudio.convert(min_ft2_per_occ, 'ft^2', 'm^2').get
54
+
55
+ return [min_area_m2, min_m2_per_occ]
56
+ end
57
+ end
@@ -0,0 +1,22 @@
1
+ class ASHRAE9012019 < ASHRAE901
2
+ # @!group ZoneHVACComponent
3
+
4
+ # Determine if vestibule heating control is required.
5
+ # Required for 90.1-2019 per 6.4.3.9.
6
+ #
7
+ # @ref [References::ASHRAE9012019] 6.4.3.9
8
+ # @return [Bool] returns true if successful, false if not
9
+ def zone_hvac_component_vestibule_heating_control_required?(zone_hvac_component)
10
+ # Ensure that the equipment is assigned to a thermal zone
11
+ if zone_hvac_component.thermalZone.empty?
12
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.model.ZoneHVACComponent', "For #{zone_hvac_component.name}: equipment is not assigned to a thermal zone, cannot apply vestibule heating control.")
13
+ return false
14
+ end
15
+
16
+ # Only applies to equipment that is in vestibule zones
17
+ return true if thermal_zone_vestibule?(zone_hvac_component.thermalZone.get)
18
+
19
+ # If here, vestibule heating control not required
20
+ return false
21
+ end
22
+ end
@@ -0,0 +1,16 @@
1
+ # This class holds methods that apply ASHRAE 90.1-2019
2
+ # to a given model.
3
+ # @ref [References::ASHRAE9012019]
4
+ class ASHRAE9012019 < ASHRAE901
5
+ register_standard '90.1-2019'
6
+ attr_reader :template
7
+
8
+ def initialize
9
+ @template = '90.1-2019'
10
+ load_standards_database
11
+ end
12
+
13
+ def load_standards_database(data_directories = [])
14
+ super([__dir__] + data_directories)
15
+ end
16
+ end
@@ -0,0 +1,68 @@
1
+ {
2
+ "boilers": [
3
+ {
4
+ "template": "90.1-2019",
5
+ "fluid_type": "Hot Water",
6
+ "fuel_type": "Gas",
7
+ "condensing": null,
8
+ "condensing_control": null,
9
+ "minimum_capacity": 0.0,
10
+ "maximum_capacity": 299999.0,
11
+ "start_date": "1919-09-09T00:00:00+00:00",
12
+ "end_date": "2999-09-09T00:00:00+00:00",
13
+ "minimum_annual_fuel_utilization_efficiency": 0.82,
14
+ "minimum_thermal_efficiency": null,
15
+ "minimum_combustion_efficiency": null,
16
+ "efffplr": "Boiler with No Minimum Turndown",
17
+ "notes": "From 90.1-2019"
18
+ },
19
+ {
20
+ "template": "90.1-2019",
21
+ "fluid_type": "Hot Water",
22
+ "fuel_type": "Gas",
23
+ "condensing": null,
24
+ "condensing_control": null,
25
+ "minimum_capacity": 300000.0,
26
+ "maximum_capacity": 999999.0,
27
+ "start_date": "1919-09-09T00:00:00+00:00",
28
+ "end_date": "2999-09-09T00:00:00+00:00",
29
+ "minimum_annual_fuel_utilization_efficiency": null,
30
+ "minimum_thermal_efficiency": 0.8,
31
+ "minimum_combustion_efficiency": null,
32
+ "efffplr": "Boiler with No Minimum Turndown",
33
+ "notes": "From 90.1-2019"
34
+ },
35
+ {
36
+ "template": "90.1-2019",
37
+ "fluid_type": "Hot Water",
38
+ "fuel_type": "Gas",
39
+ "condensing": null,
40
+ "condensing_control": null,
41
+ "minimum_capacity": 1000000.0,
42
+ "maximum_capacity": 249999999.0,
43
+ "start_date": "1919-09-09T00:00:00+00:00",
44
+ "end_date": "2999-09-09T00:00:00+00:00",
45
+ "minimum_annual_fuel_utilization_efficiency": null,
46
+ "minimum_thermal_efficiency": 0.8,
47
+ "minimum_combustion_efficiency": null,
48
+ "efffplr": "Boiler with Minimum Turndown",
49
+ "notes": "From 90.1-2019"
50
+ },
51
+ {
52
+ "template": "90.1-2019",
53
+ "fluid_type": "Hot Water",
54
+ "fuel_type": "Gas",
55
+ "condensing": null,
56
+ "condensing_control": null,
57
+ "minimum_capacity": 250000000.0,
58
+ "maximum_capacity": 9999999999.0,
59
+ "start_date": "1919-09-09T00:00:00+00:00",
60
+ "end_date": "2999-09-09T00:00:00+00:00",
61
+ "minimum_annual_fuel_utilization_efficiency": null,
62
+ "minimum_thermal_efficiency": null,
63
+ "minimum_combustion_efficiency": 0.82,
64
+ "efffplr": "Boiler with Minimum Turndown",
65
+ "notes": "From 90.1-2019"
66
+ }
67
+ ]
68
+ }