openstudio-standards 0.2.12 → 0.2.13.rc3

Sign up to get free protection for your applications and to get access to all the features.
Files changed (492) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAE90120162019HighriseApartment.json +1042 -0
  3. data/data/geometry/ASHRAE90120162019Hospital.json +199 -0
  4. data/data/geometry/ASHRAE90120162019LargeHotel.json +73 -0
  5. data/data/geometry/ASHRAE90120162019LargeOffice.json +109 -0
  6. data/data/geometry/ASHRAE90120162019SecondarySchool.json +205 -0
  7. data/data/geometry/ASHRAECourthouse.json +112 -0
  8. data/data/geometry/ASHRAECourthouse.osm +26470 -0
  9. data/data/geometry/ASHRAELargeHotel.osm +11 -1
  10. data/data/geometry/ASHRAELargeOffice.json +4 -0
  11. data/data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx +0 -0
  12. data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
  13. data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
  14. data/data/standards/exclude_list.csv +19 -0
  15. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +49 -0
  16. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +293 -0
  17. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +25426 -0
  18. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +1600 -0
  19. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +564 -0
  20. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +349 -0
  21. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +164 -0
  22. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +10663 -0
  23. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +508 -0
  24. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +156 -0
  25. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +44 -0
  26. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +184 -0
  27. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +3094 -0
  28. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +829 -0
  29. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +562 -0
  30. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +52 -0
  31. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +220 -0
  32. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +156 -0
  33. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +1316 -0
  34. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +21446 -0
  35. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +554 -0
  36. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +68 -0
  37. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +28 -0
  38. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +12 -0
  39. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +49 -0
  40. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +293 -0
  41. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +12487 -0
  42. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +1600 -0
  43. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +564 -0
  44. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +349 -0
  45. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +164 -0
  46. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +10663 -0
  47. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +466 -0
  48. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +137 -0
  49. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +44 -0
  50. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +184 -0
  51. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +3094 -0
  52. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +829 -0
  53. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +562 -0
  54. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +52 -0
  55. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +220 -0
  56. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +156 -0
  57. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +1316 -0
  58. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +21380 -0
  59. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +554 -0
  60. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +68 -0
  61. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +28 -0
  62. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +12 -0
  63. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +49 -0
  64. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +395 -0
  65. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +12487 -0
  66. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +1600 -0
  67. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +592 -0
  68. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +349 -0
  69. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +550 -0
  70. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +164 -0
  71. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +10663 -0
  72. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +466 -0
  73. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +137 -0
  74. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +44 -0
  75. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +238 -0
  76. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +3094 -0
  77. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +829 -0
  78. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +562 -0
  79. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +52 -0
  80. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +220 -0
  81. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +156 -0
  82. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +1316 -0
  83. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +21548 -0
  84. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +554 -0
  85. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +68 -0
  86. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +28 -0
  87. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +12 -0
  88. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +64 -0
  89. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +871 -0
  90. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +12487 -0
  91. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +1600 -0
  92. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +592 -0
  93. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +349 -0
  94. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +1096 -0
  95. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +164 -0
  96. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +10663 -0
  97. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +886 -0
  98. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +194 -0
  99. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +44 -0
  100. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +247 -0
  101. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +3094 -0
  102. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +829 -0
  103. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +562 -0
  104. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +52 -0
  105. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +220 -0
  106. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +156 -0
  107. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +1316 -0
  108. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +22079 -0
  109. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +994 -0
  110. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +68 -0
  111. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +28 -0
  112. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +12 -0
  113. data/data/standards/manage_OpenStudio_Standards.rb +87 -37
  114. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1-ALL-comstockspace_types.csv +236 -0
  115. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +622 -0
  116. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1space_types.csv +191 -0
  117. data/data/standards/openstudio_standards_duplicates_log.csv +16 -25
  118. data/data/standards/test_performance_expected_dd_results.csv +1934 -1134
  119. data/lib/openstudio-standards.rb +68 -17
  120. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +28 -0
  121. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +0 -1
  122. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +28 -0
  123. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +53 -2
  124. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +29 -0
  125. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +157 -2
  126. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +29 -0
  127. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
  128. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +32 -0
  129. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +33 -0
  130. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +32 -0
  131. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +25 -0
  132. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +366 -0
  133. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +144 -0
  134. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +11 -0
  135. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
  136. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +32 -0
  137. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +33 -0
  138. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +32 -0
  139. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +25 -0
  140. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +367 -0
  141. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +144 -0
  142. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +11 -0
  143. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +0 -1
  144. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +0 -1
  145. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
  146. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
  147. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
  148. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
  149. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +3 -3
  150. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +74 -0
  151. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +46 -30
  152. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +15 -7
  153. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +26 -15
  154. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +8 -11
  155. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +54 -60
  156. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +56 -60
  157. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +38 -12
  158. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +218 -134
  159. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +6 -2
  160. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +222 -133
  161. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +60 -62
  162. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +25 -15
  163. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +34 -22
  164. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +31 -7
  165. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +43 -28
  166. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +48 -38
  167. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +9 -5
  168. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +567 -344
  169. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +13 -19
  170. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +13 -17
  171. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +9 -5
  172. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +79 -51
  173. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +60 -60
  174. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +2 -4
  175. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +133 -120
  176. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +124 -112
  177. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +138 -66
  178. data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +7275 -199
  179. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +35 -35
  180. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -2
  181. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -2
  182. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +3 -3
  183. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +1 -1
  184. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +2 -2
  185. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +2 -2
  186. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
  187. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +2 -2
  188. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +2 -2
  189. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
  190. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
  191. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +4 -3
  192. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +7 -8
  193. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +7 -8
  194. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +13 -14
  195. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +7 -5
  196. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +2 -0
  197. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +0 -1
  198. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +25 -14
  199. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +474 -89
  200. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +35 -33
  201. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +3 -0
  202. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +72 -0
  203. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +120 -120
  204. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +103 -125
  205. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +9 -3
  206. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +11 -5
  207. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +26 -14
  208. data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +270 -247
  209. data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
  210. data/lib/openstudio-standards/refs/references.rb +5 -2
  211. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +41 -28
  212. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -1
  213. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +0 -1
  214. data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +1 -0
  215. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +2 -4
  216. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +8 -10
  217. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -5
  218. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +0 -1
  219. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
  220. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +12 -9
  221. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -1
  222. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +3 -1
  223. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +0 -3
  224. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +4 -7
  225. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -3
  226. data/lib/openstudio-standards/standards/Standards.Construction.rb +124 -118
  227. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +0 -1
  228. data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +0 -1
  229. data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +0 -1
  230. data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +0 -1
  231. data/lib/openstudio-standards/standards/Standards.Fan.rb +0 -1
  232. data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -1
  233. data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -1
  234. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -4
  235. data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -1
  236. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +10 -3
  237. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -1
  238. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -1
  239. data/lib/openstudio-standards/standards/Standards.Model.rb +282 -253
  240. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -0
  241. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -9
  242. data/lib/openstudio-standards/standards/Standards.Pump.rb +0 -1
  243. data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -1
  244. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +0 -1
  245. data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +0 -1
  246. data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +0 -1
  247. data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +103 -121
  248. data/lib/openstudio-standards/standards/Standards.Space.rb +42 -35
  249. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +9 -17
  250. data/lib/openstudio-standards/standards/Standards.SubSurface.rb +25 -27
  251. data/lib/openstudio-standards/standards/Standards.Surface.rb +97 -52
  252. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +39 -21
  253. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +6 -7
  254. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +15 -10
  255. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +0 -1
  256. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +10 -2
  257. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model.rb +2 -2
  258. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +63 -99
  259. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +7 -7
  260. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +2420 -0
  261. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +32 -0
  262. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +9 -0
  263. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +68 -38
  264. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +105 -40
  265. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +5 -1
  266. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +63 -99
  267. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +7 -7
  268. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +1460 -0
  269. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +32 -0
  270. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +9 -0
  271. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +68 -38
  272. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +104 -17
  273. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +25 -13
  274. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +1 -1
  275. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +63 -99
  276. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +7 -7
  277. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +1460 -0
  278. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +64 -0
  279. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +52 -0
  280. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +9 -0
  281. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +68 -38
  282. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +112 -25
  283. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +21 -7
  284. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
  285. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +63 -99
  286. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +7 -7
  287. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +1 -1
  288. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +2 -2
  289. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +1460 -0
  290. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +64 -0
  291. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +104 -0
  292. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +9 -0
  293. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +70 -40
  294. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +172 -55
  295. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +4 -4
  296. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +1 -1
  297. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +456 -0
  298. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
  299. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +19 -0
  300. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerSingleSpeed.rb +5 -0
  301. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerTwoSpeed.rb +5 -0
  302. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +16 -0
  303. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +37 -0
  304. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +189 -0
  305. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +57 -0
  306. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +22 -0
  307. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +16 -0
  308. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.boilers.json +68 -0
  309. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.chillers.json +490 -0
  310. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_properties.json +21244 -0
  311. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_sets.json +2111 -0
  312. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.economizers.json +676 -0
  313. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.elevators.json +372 -0
  314. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +1096 -0
  315. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ext_ltg.json +169 -0
  316. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +532 -0
  317. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +164 -0
  318. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_rejection.json +49 -0
  319. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.motors.json +274 -0
  320. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.prototype_inputs.json +3094 -0
  321. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_cases.json +854 -0
  322. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_lnup.json +562 -0
  323. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_compressors.json +58 -0
  324. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_condenser.json +238 -0
  325. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_system.json +12 -0
  326. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_walkins.json +1316 -0
  327. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +23067 -0
  328. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +648 -0
  329. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +72 -0
  330. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps.json +31 -0
  331. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps_heating.json +13 -0
  332. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +456 -0
  333. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
  334. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +19 -0
  335. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerSingleSpeed.rb +5 -0
  336. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerTwoSpeed.rb +5 -0
  337. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +16 -0
  338. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +37 -0
  339. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +189 -0
  340. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +57 -0
  341. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +22 -0
  342. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +16 -0
  343. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +68 -0
  344. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.chillers.json +490 -0
  345. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_properties.json +21244 -0
  346. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_sets.json +2111 -0
  347. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.economizers.json +676 -0
  348. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.elevators.json +372 -0
  349. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +1096 -0
  350. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ext_ltg.json +169 -0
  351. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +664 -0
  352. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +204 -0
  353. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_rejection.json +49 -0
  354. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.motors.json +274 -0
  355. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.prototype_inputs.json +3094 -0
  356. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_cases.json +854 -0
  357. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_lnup.json +562 -0
  358. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +58 -0
  359. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_condenser.json +238 -0
  360. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_system.json +12 -0
  361. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_walkins.json +1316 -0
  362. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +23067 -0
  363. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +671 -0
  364. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +72 -0
  365. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps.json +31 -0
  366. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps_heating.json +13 -0
  367. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +1662 -332
  368. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.materials.json +5049 -289
  369. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +1743 -161
  370. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +63 -99
  371. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +11 -11
  372. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.heat_rejection.json +9 -0
  373. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +8 -8
  374. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +9 -9
  375. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +4 -4
  376. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +63 -99
  377. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ext_ltg.json +10 -10
  378. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.heat_rejection.json +9 -0
  379. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +7 -7
  380. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +9 -9
  381. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +4 -4
  382. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_rejection.json +9 -0
  383. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +0 -1
  384. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +4 -4
  385. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
  386. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +1 -1
  387. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json +9 -0
  388. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json +2 -2
  389. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +3 -6
  390. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +4 -4
  391. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
  392. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +1 -1
  393. data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -3
  394. data/lib/openstudio-standards/standards/cbes/cbes.rb +1 -1
  395. data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +8 -13
  396. data/lib/openstudio-standards/standards/deer/deer.Model.rb +2 -2
  397. data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +2 -0
  398. data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
  399. data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +0 -1
  400. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +0 -1
  401. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +0 -1
  402. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +0 -1
  403. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +0 -1
  404. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +1 -1
  405. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
  406. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +0 -1
  407. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +1 -1
  408. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
  409. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +0 -1
  410. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +1 -1
  411. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
  412. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +0 -1
  413. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +1 -1
  414. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
  415. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +0 -1
  416. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +1 -1
  417. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
  418. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +0 -1
  419. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +1 -1
  420. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
  421. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +0 -1
  422. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +1 -1
  423. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
  424. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +0 -1
  425. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +1 -1
  426. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
  427. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +0 -1
  428. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +1 -1
  429. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
  430. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +0 -1
  431. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +1 -1
  432. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
  433. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +0 -1
  434. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +1 -1
  435. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
  436. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +0 -1
  437. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +1 -1
  438. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
  439. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +0 -1
  440. data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +0 -1
  441. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +28 -7
  442. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +16 -2
  443. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +15 -0
  444. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +14 -0
  445. data/lib/openstudio-standards/standards/necb/ECMS/data/erv.json +11 -7
  446. data/lib/openstudio-standards/standards/necb/ECMS/data/pv.json +112 -0
  447. data/lib/openstudio-standards/standards/necb/ECMS/data/unitary_acs.json +50 -0
  448. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +21 -8
  449. data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +17 -6
  450. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +142 -6
  451. data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +189 -0
  452. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +104 -0
  453. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +19 -13
  454. data/lib/openstudio-standards/standards/necb/NECB2011/data/erv.json +1 -1
  455. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +39278 -0
  456. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +17 -1
  457. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +15 -0
  458. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +14 -2
  459. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +13 -0
  460. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +12 -0
  461. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +154 -12
  462. data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +21 -3
  463. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +140 -21
  464. data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +74 -0
  465. data/lib/openstudio-standards/standards/necb/NECB2011/pv_ground.md +44 -0
  466. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +2 -2
  467. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/qaqc_resources/neb_end_use_prices.csv +39 -84
  468. data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +0 -1
  469. data/lib/openstudio-standards/standards/standard.rb +6 -5
  470. data/lib/openstudio-standards/utilities/Add_template_field_to_json.rb +3 -3
  471. data/lib/openstudio-standards/utilities/convert_surfaces_to_adiabatic_necb_8426.rb +54 -54
  472. data/lib/openstudio-standards/utilities/generate_prototype_database.rb +2 -2
  473. data/lib/openstudio-standards/utilities/generate_space_types.rb +3 -3
  474. data/lib/openstudio-standards/utilities/logging.rb +7 -7
  475. data/lib/openstudio-standards/utilities/necb_to_epw_map.rb +14 -14
  476. data/lib/openstudio-standards/utilities/os_sim_extract.rb +25 -25
  477. data/lib/openstudio-standards/utilities/rename_surfaces.rb +10 -13
  478. data/lib/openstudio-standards/utilities/round_surf_coords.rb +18 -20
  479. data/lib/openstudio-standards/utilities/sched_create.rb +39 -41
  480. data/lib/openstudio-standards/utilities/set_mult_to_adiabatic.rb +31 -31
  481. data/lib/openstudio-standards/utilities/simulation.rb +5 -3
  482. data/lib/openstudio-standards/utilities/speacetype_map_converter.rb +10 -11
  483. data/lib/openstudio-standards/utilities/sqlfile.rb +6 -8
  484. data/lib/openstudio-standards/utilities/template_measure/measure.rb +108 -0
  485. data/lib/openstudio-standards/utilities/template_measure/measure.xml +162 -0
  486. data/lib/openstudio-standards/utilities/template_measure/resources/BTAPMeasureHelper.rb +448 -0
  487. data/lib/openstudio-standards/utilities/template_measure/tests/test.rb +160 -0
  488. data/lib/openstudio-standards/utilities/weatherData1_xlsx_to_json.rb +23 -26
  489. data/lib/openstudio-standards/version.rb +1 -1
  490. data/lib/openstudio-standards/weather/Weather.Model.rb +74 -80
  491. data/lib/openstudio-standards/weather/Weather.stat_file.rb +17 -17
  492. metadata +217 -2
@@ -0,0 +1,72 @@
1
+ {
2
+ "water_heaters": [
3
+ {
4
+ "template": "90.1-2016",
5
+ "fuel_type": "Electricity",
6
+ "minimum_capacity": 0.0,
7
+ "maximum_capacity": 40945.99,
8
+ "start_date": "1919-09-09T00:00:00+00:00",
9
+ "end_date": "2999-09-09T00:00:00+00:00",
10
+ "energy_factor_base": 0.96,
11
+ "energy_factor_volume_derate": 0.0003,
12
+ "standby_loss_base": null,
13
+ "standby_loss_capacity_allowance": null,
14
+ "standby_loss_volume_allowance": null,
15
+ "hourly_loss_base": null,
16
+ "hourly_loss_volume_allowance": null,
17
+ "thermal_efficiency": null,
18
+ "notes": "From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal"
19
+ },
20
+ {
21
+ "template": "90.1-2016",
22
+ "fuel_type": "Electricity",
23
+ "minimum_capacity": 40946.0,
24
+ "maximum_capacity": 99999999.0,
25
+ "start_date": "1919-09-09T00:00:00+00:00",
26
+ "end_date": "2999-09-09T00:00:00+00:00",
27
+ "energy_factor_base": null,
28
+ "energy_factor_volume_derate": null,
29
+ "standby_loss_base": null,
30
+ "standby_loss_capacity_allowance": null,
31
+ "standby_loss_volume_allowance": null,
32
+ "hourly_loss_base": 0.3,
33
+ "hourly_loss_volume_allowance": 27.0,
34
+ "thermal_efficiency": null,
35
+ "notes": null
36
+ },
37
+ {
38
+ "template": "90.1-2016",
39
+ "fuel_type": "NaturalGas",
40
+ "minimum_capacity": 0.0,
41
+ "maximum_capacity": 74999.99,
42
+ "start_date": "1919-09-09T00:00:00+00:00",
43
+ "end_date": "2999-09-09T00:00:00+00:00",
44
+ "energy_factor_base": 0.675,
45
+ "energy_factor_volume_derate": 0.0015,
46
+ "standby_loss_base": null,
47
+ "standby_loss_capacity_allowance": null,
48
+ "standby_loss_volume_allowance": null,
49
+ "hourly_loss_base": null,
50
+ "hourly_loss_volume_allowance": null,
51
+ "thermal_efficiency": null,
52
+ "notes": "From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal"
53
+ },
54
+ {
55
+ "template": "90.1-2016",
56
+ "fuel_type": "NaturalGas",
57
+ "minimum_capacity": 75000.0,
58
+ "maximum_capacity": 99999999.0,
59
+ "start_date": "1919-09-09T00:00:00+00:00",
60
+ "end_date": "2999-09-09T00:00:00+00:00",
61
+ "energy_factor_base": null,
62
+ "energy_factor_volume_derate": null,
63
+ "standby_loss_base": null,
64
+ "standby_loss_capacity_allowance": 800.0,
65
+ "standby_loss_volume_allowance": 110.0,
66
+ "hourly_loss_base": null,
67
+ "hourly_loss_volume_allowance": null,
68
+ "thermal_efficiency": 0.8,
69
+ "notes": null
70
+ }
71
+ ]
72
+ }
@@ -0,0 +1,31 @@
1
+ {
2
+ "water_source_heat_pumps": [
3
+ {
4
+ "template": "90.1-2016",
5
+ "minimum_capacity": 0.0,
6
+ "maximum_capacity": 16999.0,
7
+ "start_date": "1919-09-09T00:00:00+00:00",
8
+ "end_date": "2999-09-09T00:00:00+00:00",
9
+ "minimum_full_load_efficiency": 12.2,
10
+ "notes": null
11
+ },
12
+ {
13
+ "template": "90.1-2016",
14
+ "minimum_capacity": 17000.0,
15
+ "maximum_capacity": 64999.0,
16
+ "start_date": "1919-09-09T00:00:00+00:00",
17
+ "end_date": "2999-09-09T00:00:00+00:00",
18
+ "minimum_full_load_efficiency": 13.0,
19
+ "notes": null
20
+ },
21
+ {
22
+ "template": "90.1-2016",
23
+ "minimum_capacity": 65000.0,
24
+ "maximum_capacity": 134999.0,
25
+ "start_date": "1919-09-09T00:00:00+00:00",
26
+ "end_date": "2999-09-09T00:00:00+00:00",
27
+ "minimum_full_load_efficiency": 13.0,
28
+ "notes": null
29
+ }
30
+ ]
31
+ }
@@ -0,0 +1,13 @@
1
+ {
2
+ "water_source_heat_pumps_heating": [
3
+ {
4
+ "template": "90.1-2016",
5
+ "minimum_capacity": 0.0,
6
+ "maximum_capacity": 9999999.0,
7
+ "start_date": "1919-09-09T00:00:00+00:00",
8
+ "end_date": "2999-09-09T00:00:00+00:00",
9
+ "minimum_coefficient_of_performance_heating": 4.3,
10
+ "notes": "From 90.1-2016 Table 6.8.1-2"
11
+ }
12
+ ]
13
+ }
@@ -0,0 +1,456 @@
1
+ class ASHRAE9012019 < ASHRAE901
2
+ # @!group AirLoopHVAC
3
+
4
+ # Apply multizone vav outdoor air method and
5
+ # adjust multizone VAV damper positions
6
+ # to achieve a system minimum ventilation effectiveness
7
+ # of 0.6 per PNNL. Hard-size the resulting min OA
8
+ # into the sizing:system object.
9
+ #
10
+ # return [Bool] returns true if successful, false if not
11
+ # @todo move building-type-specific code to Prototype classes
12
+ def air_loop_hvac_apply_multizone_vav_outdoor_air_sizing(air_loop_hvac)
13
+ # First time adjustment:
14
+ # Only applies to multi-zone vav systems
15
+ # exclusion: for Outpatient: (1) both AHU1 and AHU2 in 'DOE Ref Pre-1980' and 'DOE Ref 1980-2004'
16
+ # (2) AHU1 in 2004-2019
17
+ # TODO refactor: move building-type-specific code to Prototype classes
18
+ if air_loop_hvac_multizone_vav_system?(air_loop_hvac) && !(air_loop_hvac.name.to_s.include? 'Outpatient F1')
19
+ air_loop_hvac_adjust_minimum_vav_damper_positions(air_loop_hvac)
20
+ end
21
+
22
+ return true
23
+ end
24
+
25
+ # Determine the limits for the type of economizer present on the AirLoopHVAC, if any.
26
+ # @return [Array<Double>] [drybulb_limit_f, enthalpy_limit_btu_per_lb, dewpoint_limit_f]
27
+ def air_loop_hvac_economizer_limits(air_loop_hvac, climate_zone)
28
+ drybulb_limit_f = nil
29
+ enthalpy_limit_btu_per_lb = nil
30
+ dewpoint_limit_f = nil
31
+
32
+ # Get the OA system and OA controller
33
+ oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
34
+ if oa_sys.is_initialized
35
+ oa_sys = oa_sys.get
36
+ else
37
+ return [nil, nil, nil] # No OA system
38
+ end
39
+ oa_control = oa_sys.getControllerOutdoorAir
40
+ economizer_type = oa_control.getEconomizerControlType
41
+ oa_control.resetEconomizerMinimumLimitDryBulbTemperature
42
+
43
+ case economizer_type
44
+ when 'NoEconomizer'
45
+ OpenStudio.logFree(OpenStudio::Debug, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name} no economizer")
46
+ return [nil, nil, nil]
47
+ when 'FixedDryBulb'
48
+ search_criteria = {
49
+ 'template' => template,
50
+ 'climate_zone' => climate_zone
51
+ }
52
+ econ_limits = model_find_object(standards_data['economizers'], search_criteria)
53
+ drybulb_limit_f = econ_limits['fixed_dry_bulb_high_limit_shutoff_temp']
54
+ when 'FixedEnthalpy'
55
+ enthalpy_limit_btu_per_lb = 28.0
56
+ when 'FixedDewPointAndDryBulb'
57
+ drybulb_limit_f = 75.0
58
+ dewpoint_limit_f = 55.0
59
+ when 'DifferentialDryBulb', 'DifferentialEnthalpy'
60
+ OpenStudio.logFree(OpenStudio::Debug, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Economizer type = #{economizer_type}, no limits defined.")
61
+ end
62
+
63
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Economizer type = #{economizer_type}, limits [#{drybulb_limit_f},#{enthalpy_limit_btu_per_lb},#{dewpoint_limit_f}]")
64
+
65
+ return [drybulb_limit_f, enthalpy_limit_btu_per_lb, dewpoint_limit_f]
66
+ end
67
+
68
+ # Determine if the system economizer must be integrated or not.
69
+ # All economizers must be integrated in 90.1-2019
70
+ def air_loop_hvac_integrated_economizer_required?(air_loop_hvac, climate_zone)
71
+ integrated_economizer_required = true
72
+ return integrated_economizer_required
73
+ end
74
+
75
+ # Check the economizer type currently specified in the ControllerOutdoorAir object on this air loop
76
+ # is acceptable per the standard.
77
+ #
78
+ # @param (see #economizer_required?)
79
+ # @return [Bool] Returns true if allowable, if the system has no economizer or no OA system.
80
+ # Returns false if the economizer type is not allowable.
81
+ def air_loop_hvac_economizer_type_allowable?(air_loop_hvac, climate_zone)
82
+ # EnergyPlus economizer types
83
+ # 'NoEconomizer'
84
+ # 'FixedDryBulb'
85
+ # 'FixedEnthalpy'
86
+ # 'DifferentialDryBulb'
87
+ # 'DifferentialEnthalpy'
88
+ # 'FixedDewPointAndDryBulb'
89
+ # 'ElectronicEnthalpy'
90
+ # 'DifferentialDryBulbAndEnthalpy'
91
+
92
+ # Get the OA system and OA controller
93
+ oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
94
+ if oa_sys.is_initialized
95
+ oa_sys = oa_sys.get
96
+ else
97
+ return true # No OA system
98
+ end
99
+ oa_control = oa_sys.getControllerOutdoorAir
100
+ economizer_type = oa_control.getEconomizerControlType
101
+
102
+ # Return true if no economizer is present
103
+ if economizer_type == 'NoEconomizer'
104
+ return true
105
+ end
106
+
107
+ # Determine the prohibited types
108
+ prohibited_types = []
109
+ case climate_zone
110
+ when 'ASHRAE 169-2006-0B',
111
+ 'ASHRAE 169-2006-1B',
112
+ 'ASHRAE 169-2006-2B',
113
+ 'ASHRAE 169-2006-3B',
114
+ 'ASHRAE 169-2006-3C',
115
+ 'ASHRAE 169-2006-4B',
116
+ 'ASHRAE 169-2006-4C',
117
+ 'ASHRAE 169-2006-5B',
118
+ 'ASHRAE 169-2006-6B',
119
+ 'ASHRAE 169-2006-7A',
120
+ 'ASHRAE 169-2006-7B',
121
+ 'ASHRAE 169-2006-8A',
122
+ 'ASHRAE 169-2006-8B',
123
+ 'ASHRAE 169-2013-0B',
124
+ 'ASHRAE 169-2013-1B',
125
+ 'ASHRAE 169-2013-2B',
126
+ 'ASHRAE 169-2013-3B',
127
+ 'ASHRAE 169-2013-3C',
128
+ 'ASHRAE 169-2013-4B',
129
+ 'ASHRAE 169-2013-4C',
130
+ 'ASHRAE 169-2013-5B',
131
+ 'ASHRAE 169-2013-6B',
132
+ 'ASHRAE 169-2013-7A',
133
+ 'ASHRAE 169-2013-7B',
134
+ 'ASHRAE 169-2013-8A',
135
+ 'ASHRAE 169-2013-8B'
136
+ prohibited_types = ['FixedEnthalpy']
137
+ when 'ASHRAE 169-2006-0A',
138
+ 'ASHRAE 169-2006-1A',
139
+ 'ASHRAE 169-2006-2A',
140
+ 'ASHRAE 169-2006-3A',
141
+ 'ASHRAE 169-2006-4A',
142
+ 'ASHRAE 169-2013-0A',
143
+ 'ASHRAE 169-2013-1A',
144
+ 'ASHRAE 169-2013-2A',
145
+ 'ASHRAE 169-2013-3A',
146
+ 'ASHRAE 169-2013-4A'
147
+ prohibited_types = ['FixedDryBulb', 'DifferentialDryBulb']
148
+ when 'ASHRAE 169-2006-5A',
149
+ 'ASHRAE 169-2006-6A',
150
+ 'ASHRAE 169-2013-5A',
151
+ 'ASHRAE 169-2013-6A'
152
+ prohibited_types = []
153
+ end
154
+
155
+ # Check if the specified type is allowed
156
+ economizer_type_allowed = true
157
+ if prohibited_types.include?(economizer_type)
158
+ economizer_type_allowed = false
159
+ end
160
+
161
+ return economizer_type_allowed
162
+ end
163
+
164
+ # Determine if multizone vav optimization is required.
165
+ #
166
+ # @code_sections [90.1-2019_6.5.3.3]
167
+ # @param (see #economizer_required?)
168
+ # @return [Bool] Returns true if required, false if not.
169
+ # @todo Add exception logic for
170
+ # systems with AIA healthcare ventilation requirements
171
+ # dual duct systems
172
+ def air_loop_hvac_multizone_vav_optimization_required?(air_loop_hvac, climate_zone)
173
+ multizone_opt_required = false
174
+
175
+ # Not required for systems with fan-powered terminals
176
+ num_fan_powered_terminals = 0
177
+ air_loop_hvac.demandComponents.each do |comp|
178
+ if comp.to_AirTerminalSingleDuctParallelPIUReheat.is_initialized || comp.to_AirTerminalSingleDuctSeriesPIUReheat.is_initialized
179
+ num_fan_powered_terminals += 1
180
+ end
181
+ end
182
+ if num_fan_powered_terminals > 0
183
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}, multizone vav optimization is not required because the system has #{num_fan_powered_terminals} fan-powered terminals.")
184
+ return multizone_opt_required
185
+ end
186
+
187
+ # Get the OA intake
188
+ controller_oa = nil
189
+ controller_mv = nil
190
+ oa_system = nil
191
+ if air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
192
+ oa_system = air_loop_hvac.airLoopHVACOutdoorAirSystem.get
193
+ controller_oa = oa_system.getControllerOutdoorAir
194
+ controller_mv = controller_oa.controllerMechanicalVentilation
195
+ else
196
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}, multizone optimization is not applicable because system has no OA intake.")
197
+ return multizone_opt_required
198
+ end
199
+
200
+ # Get the AHU design supply air flow rate
201
+ dsn_flow_m3_per_s = nil
202
+ if air_loop_hvac.designSupplyAirFlowRate.is_initialized
203
+ dsn_flow_m3_per_s = air_loop_hvac.designSupplyAirFlowRate.get
204
+ elsif air_loop_hvac.autosizedDesignSupplyAirFlowRate.is_initialized
205
+ dsn_flow_m3_per_s = air_loop_hvac.autosizedDesignSupplyAirFlowRate.get
206
+ else
207
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name} design supply air flow rate is not available, cannot apply efficiency standard.")
208
+ return multizone_opt_required
209
+ end
210
+ dsn_flow_cfm = OpenStudio.convert(dsn_flow_m3_per_s, 'm^3/s', 'cfm').get
211
+
212
+ # Get the minimum OA flow rate
213
+ min_oa_flow_m3_per_s = nil
214
+ if controller_oa.minimumOutdoorAirFlowRate.is_initialized
215
+ min_oa_flow_m3_per_s = controller_oa.minimumOutdoorAirFlowRate.get
216
+ elsif controller_oa.autosizedMinimumOutdoorAirFlowRate.is_initialized
217
+ min_oa_flow_m3_per_s = controller_oa.autosizedMinimumOutdoorAirFlowRate.get
218
+ else
219
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', "For #{controller_oa.name}: minimum OA flow rate is not available, cannot apply efficiency standard.")
220
+ return multizone_opt_required
221
+ end
222
+ min_oa_flow_cfm = OpenStudio.convert(min_oa_flow_m3_per_s, 'm^3/s', 'cfm').get
223
+
224
+ # Calculate the percent OA at design airflow
225
+ pct_oa = min_oa_flow_m3_per_s / dsn_flow_m3_per_s
226
+
227
+ # Not required for systems where
228
+ # exhaust is more than 70% of the total OA intake.
229
+ if pct_oa > 0.7
230
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{controller_oa.name}: multizone optimization is not applicable because system is more than 70% OA.")
231
+ return multizone_opt_required
232
+ end
233
+
234
+ # TODO: Not required for dual-duct systems
235
+ # if self.isDualDuct
236
+ # OpenStudio::logFree(OpenStudio::Info, "openstudio.standards.AirLoopHVAC", "For #{controller_oa.name}: multizone optimization is not applicable because it is a dual duct system")
237
+ # return multizone_opt_required
238
+ # end
239
+
240
+ # If here, multizone vav optimization is required
241
+ multizone_opt_required = true
242
+
243
+ return multizone_opt_required
244
+ end
245
+
246
+ # Determines the OA flow rates above which an economizer is required.
247
+ # Two separate rates, one for systems with an economizer and another
248
+ # for systems without.
249
+ # are zero for both types.
250
+ # @return [Array<Double>] [min_oa_without_economizer_cfm, min_oa_with_economizer_cfm]
251
+ def air_loop_hvac_demand_control_ventilation_limits(air_loop_hvac)
252
+ min_oa_without_economizer_cfm = 3000
253
+ min_oa_with_economizer_cfm = 750
254
+ return [min_oa_without_economizer_cfm, min_oa_with_economizer_cfm]
255
+ end
256
+
257
+ # Determine the air flow and number of story limits for whether motorized OA damper is required.
258
+ # @return [Array<Double>] [minimum_oa_flow_cfm, maximum_stories]
259
+ def air_loop_hvac_motorized_oa_damper_limits(air_loop_hvac, climate_zone)
260
+ case climate_zone
261
+ when 'ASHRAE 169-2006-0A',
262
+ 'ASHRAE 169-2006-1A',
263
+ 'ASHRAE 169-2006-0B',
264
+ 'ASHRAE 169-2006-1B',
265
+ 'ASHRAE 169-2006-2A',
266
+ 'ASHRAE 169-2006-2B',
267
+ 'ASHRAE 169-2006-3A',
268
+ 'ASHRAE 169-2006-3B',
269
+ 'ASHRAE 169-2006-3C',
270
+ 'ASHRAE 169-2013-0A',
271
+ 'ASHRAE 169-2013-1A',
272
+ 'ASHRAE 169-2013-0B',
273
+ 'ASHRAE 169-2013-1B',
274
+ 'ASHRAE 169-2013-2A',
275
+ 'ASHRAE 169-2013-2B',
276
+ 'ASHRAE 169-2013-3A',
277
+ 'ASHRAE 169-2013-3B',
278
+ 'ASHRAE 169-2013-3C'
279
+ minimum_oa_flow_cfm = 0
280
+ maximum_stories = 999 # Any number of stories
281
+ else
282
+ minimum_oa_flow_cfm = 0
283
+ maximum_stories = 0
284
+ end
285
+
286
+ return [minimum_oa_flow_cfm, maximum_stories]
287
+ end
288
+
289
+ # Determine the number of stages that should be used as controls for single zone DX systems.
290
+ # 90.1-2019 depends on the cooling capacity of the system.
291
+ #
292
+ # @return [Integer] the number of stages: 0, 1, 2
293
+ def air_loop_hvac_single_zone_controls_num_stages(air_loop_hvac, climate_zone)
294
+ min_clg_cap_btu_per_hr = 65_000
295
+ clg_cap_btu_per_hr = OpenStudio.convert(air_loop_hvac_total_cooling_capacity(air_loop_hvac), 'W', 'Btu/hr').get
296
+ if clg_cap_btu_per_hr >= min_clg_cap_btu_per_hr
297
+ num_stages = 2
298
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: two-stage control is required since cooling capacity of #{clg_cap_btu_per_hr.round} Btu/hr exceeds the minimum of #{min_clg_cap_btu_per_hr.round} Btu/hr .")
299
+ else
300
+ num_stages = 1
301
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: two-stage control is not required since cooling capacity of #{clg_cap_btu_per_hr.round} Btu/hr is less than the minimum of #{min_clg_cap_btu_per_hr.round} Btu/hr .")
302
+ end
303
+
304
+ return num_stages
305
+ end
306
+
307
+ # Determine if the system required supply air temperature (SAT) reset.
308
+ # For 90.1-2019, SAT reset requirements are based on climate zone.
309
+ #
310
+ # @param (see #economizer_required?)
311
+ # @return [Bool] Returns true if required, false if not.
312
+ def air_loop_hvac_supply_air_temperature_reset_required?(air_loop_hvac, climate_zone)
313
+ is_sat_reset_required = false
314
+
315
+ # Only required for multizone VAV systems
316
+ unless air_loop_hvac_multizone_vav_system?(air_loop_hvac)
317
+ return is_sat_reset_required
318
+ end
319
+
320
+ case climate_zone
321
+ when 'ASHRAE 169-2006-0A',
322
+ 'ASHRAE 169-2006-1A',
323
+ 'ASHRAE 169-2006-2A',
324
+ 'ASHRAE 169-2006-3A',
325
+ 'ASHRAE 169-2013-0A',
326
+ 'ASHRAE 169-2013-1A',
327
+ 'ASHRAE 169-2013-2A',
328
+ 'ASHRAE 169-2013-3A'
329
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is not required per 6.5.3.4 Exception 1, the system is located in climate zone #{climate_zone}.")
330
+ return is_sat_reset_required
331
+ when 'ASHRAE 169-2006-0B',
332
+ 'ASHRAE 169-2006-1B',
333
+ 'ASHRAE 169-2006-2B',
334
+ 'ASHRAE 169-2006-3B',
335
+ 'ASHRAE 169-2006-3C',
336
+ 'ASHRAE 169-2006-4A',
337
+ 'ASHRAE 169-2006-4B',
338
+ 'ASHRAE 169-2006-4C',
339
+ 'ASHRAE 169-2006-5A',
340
+ 'ASHRAE 169-2006-5B',
341
+ 'ASHRAE 169-2006-5C',
342
+ 'ASHRAE 169-2006-6A',
343
+ 'ASHRAE 169-2006-6B',
344
+ 'ASHRAE 169-2006-7A',
345
+ 'ASHRAE 169-2006-7B',
346
+ 'ASHRAE 169-2006-8A',
347
+ 'ASHRAE 169-2006-8B',
348
+ 'ASHRAE 169-2013-0B',
349
+ 'ASHRAE 169-2013-1B',
350
+ 'ASHRAE 169-2013-2B',
351
+ 'ASHRAE 169-2013-3B',
352
+ 'ASHRAE 169-2013-3C',
353
+ 'ASHRAE 169-2013-4A',
354
+ 'ASHRAE 169-2013-4B',
355
+ 'ASHRAE 169-2013-4C',
356
+ 'ASHRAE 169-2013-5A',
357
+ 'ASHRAE 169-2013-5B',
358
+ 'ASHRAE 169-2013-5C',
359
+ 'ASHRAE 169-2013-6A',
360
+ 'ASHRAE 169-2013-6B',
361
+ 'ASHRAE 169-2013-7A',
362
+ 'ASHRAE 169-2013-7B',
363
+ 'ASHRAE 169-2013-8A',
364
+ 'ASHRAE 169-2013-8B'
365
+ is_sat_reset_required = true
366
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is required.")
367
+ return is_sat_reset_required
368
+ end
369
+ end
370
+
371
+ # Determine the airflow limits that govern whether or not an ERV is required.
372
+ # Based on climate zone and % OA, plus the number of operating hours the system has.
373
+ # @return [Double] the flow rate above which an ERV is required.
374
+ # if nil, ERV is never required.
375
+ def air_loop_hvac_energy_recovery_ventilator_flow_limit(air_loop_hvac, climate_zone, pct_oa)
376
+ # Calculate the number of system operating hours
377
+ # based on the availability schedule.
378
+ ann_op_hrs = 0.0
379
+ avail_sch = air_loop_hvac.availabilitySchedule
380
+ if avail_sch == air_loop_hvac.model.alwaysOnDiscreteSchedule
381
+ ann_op_hrs = 8760.0
382
+ elsif avail_sch.to_ScheduleRuleset.is_initialized
383
+ avail_sch = avail_sch.to_ScheduleRuleset.get
384
+ ann_op_hrs = schedule_ruleset_annual_hours_above_value(avail_sch, 0.0)
385
+ else
386
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.ashrae_90_1_2019.AirLoopHVAC', "For #{air_loop_hvac.name}: could not determine annual operating hours. Assuming less than 8,000 for ERV determination.")
387
+ end
388
+
389
+ if ann_op_hrs < 8000.0
390
+ # Table 6.5.6.1-1, less than 8000 hrs
391
+ search_criteria = {
392
+ 'template' => template,
393
+ 'climate_zone' => climate_zone,
394
+ 'under_8000_hours' => true
395
+ }
396
+ energy_recovery_limits = model_find_object(standards_data['energy_recovery'], search_criteria)
397
+ if energy_recovery_limits.nil?
398
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.ashrae_90_1_2019.AirLoopHVAC', "Cannot find energy recovery limits for template '#{template}', climate zone '#{climate_zone}', and under 8000 hours, assuming no energy recovery required.")
399
+ return nil
400
+ end
401
+
402
+ if pct_oa < 0.1
403
+ erv_cfm = nil
404
+ elsif pct_oa >= 0.1 && pct_oa < 0.2
405
+ erv_cfm = energy_recovery_limits['10_to_20_percent_oa']
406
+ elsif pct_oa >= 0.2 && pct_oa < 0.3
407
+ erv_cfm = energy_recovery_limits['20_to_30_percent_oa']
408
+ elsif pct_oa >= 0.3 && pct_oa < 0.4
409
+ erv_cfm = energy_recovery_limits['30_to_40_percent_oa']
410
+ elsif pct_oa >= 0.4 && pct_oa < 0.5
411
+ erv_cfm = energy_recovery_limits['40_to_50_percent_oa']
412
+ elsif pct_oa >= 0.5 && pct_oa < 0.6
413
+ erv_cfm = energy_recovery_limits['50_to_60_percent_oa']
414
+ elsif pct_oa >= 0.6 && pct_oa < 0.7
415
+ erv_cfm = energy_recovery_limits['60_to_70_percent_oa']
416
+ elsif pct_oa >= 0.7 && pct_oa < 0.8
417
+ erv_cfm = energy_recovery_limits['70_to_80_percent_oa']
418
+ elsif pct_oa >= 0.8
419
+ erv_cfm = energy_recovery_limits['greater_than_80_percent_oa']
420
+ end
421
+ else
422
+ # Table 6.5.6.1-2, above 8000 hrs
423
+ search_criteria = {
424
+ 'template' => template,
425
+ 'climate_zone' => climate_zone,
426
+ 'under_8000_hours' => false
427
+ }
428
+ energy_recovery_limits = model_find_object(standards_data['energy_recovery'], search_criteria)
429
+ if energy_recovery_limits.nil?
430
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.ashrae_90_1_2019.AirLoopHVAC', "Cannot find energy recovery limits for template '#{template}', climate zone '#{climate_zone}', and under 8000 hours, assuming no energy recovery required.")
431
+ return nil
432
+ end
433
+ if pct_oa < 0.1
434
+ erv_cfm = nil
435
+ elsif pct_oa >= 0.1 && pct_oa < 0.2
436
+ erv_cfm = energy_recovery_limits['10_to_20_percent_oa']
437
+ elsif pct_oa >= 0.2 && pct_oa < 0.3
438
+ erv_cfm = energy_recovery_limits['20_to_30_percent_oa']
439
+ elsif pct_oa >= 0.3 && pct_oa < 0.4
440
+ erv_cfm = energy_recovery_limits['30_to_40_percent_oa']
441
+ elsif pct_oa >= 0.4 && pct_oa < 0.5
442
+ erv_cfm = energy_recovery_limits['40_to_50_percent_oa']
443
+ elsif pct_oa >= 0.5 && pct_oa < 0.6
444
+ erv_cfm = energy_recovery_limits['50_to_60_percent_oa']
445
+ elsif pct_oa >= 0.6 && pct_oa < 0.7
446
+ erv_cfm = energy_recovery_limits['60_to_70_percent_oa']
447
+ elsif pct_oa >= 0.7 && pct_oa < 0.8
448
+ erv_cfm = energy_recovery_limits['70_to_80_percent_oa']
449
+ elsif pct_oa >= 0.8
450
+ erv_cfm = energy_recovery_limits['greater_than_80_percent_oa']
451
+ end
452
+ end
453
+
454
+ return erv_cfm
455
+ end
456
+ end