openstudio-standards 0.1.3 → 0.1.4

Sign up to get free protection for your applications and to get access to all the features.
Files changed (59) hide show
  1. checksums.yaml +4 -4
  2. data/data/standards/OpenStudio_Standards.xlsx +0 -0
  3. data/data/standards/OpenStudio_Standards_chillers.json +5 -5
  4. data/data/standards/OpenStudio_Standards_construction_sets.json +2 -2
  5. data/data/standards/OpenStudio_Standards_curve_cubics.json +12 -0
  6. data/data/standards/OpenStudio_Standards_heat_pumps.json +2126 -72
  7. data/data/standards/OpenStudio_Standards_heat_pumps_heating.json +766 -14
  8. data/data/standards/OpenStudio_Standards_heat_rejection.json +172 -0
  9. data/data/standards/OpenStudio_Standards_prototype_inputs.json +355 -267
  10. data/data/standards/OpenStudio_Standards_schedules.json +262 -10
  11. data/data/standards/OpenStudio_Standards_space_types.json +1466 -794
  12. data/data/standards/manage_OpenStudio_Standards.rb +19 -21
  13. data/data/weather/weather_info.csv +96 -0
  14. data/lib/openstudio-standards/btap/btap.rb +1 -1
  15. data/lib/openstudio-standards/btap/compliance.rb +135 -40
  16. data/lib/openstudio-standards/btap/envelope.rb +26 -5
  17. data/lib/openstudio-standards/btap/geometry.rb +11 -1
  18. data/lib/openstudio-standards/btap/hvac.rb +489 -56
  19. data/lib/openstudio-standards/btap/simmanager.rb +1 -1
  20. data/lib/openstudio-standards/hvac_sizing/HVACSizing.CoilHeatingDXMultiSpeed.rb +120 -0
  21. data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingDXMultiSpeed.rb +151 -7
  22. data/lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingGasMultiStage.rb +48 -7
  23. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +14 -12
  24. data/lib/openstudio-standards/prototypes/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -7
  25. data/lib/openstudio-standards/prototypes/Prototype.Model.hvac.rb +123 -91
  26. data/lib/openstudio-standards/prototypes/Prototype.Model.rb +130 -45
  27. data/lib/openstudio-standards/prototypes/Prototype.Model.swh.rb +13 -7
  28. data/lib/openstudio-standards/prototypes/Prototype.full_service_restaurant.rb +332 -324
  29. data/lib/openstudio-standards/prototypes/Prototype.hospital.rb +401 -99
  30. data/lib/openstudio-standards/prototypes/Prototype.hvac_systems.rb +309 -222
  31. data/lib/openstudio-standards/prototypes/Prototype.large_hotel.rb +100 -80
  32. data/lib/openstudio-standards/prototypes/Prototype.large_office.rb +37 -22
  33. data/lib/openstudio-standards/prototypes/Prototype.medium_office.rb +68 -53
  34. data/lib/openstudio-standards/prototypes/Prototype.mid_rise_apartment.rb +109 -88
  35. data/lib/openstudio-standards/prototypes/Prototype.outpatient.rb +52 -4
  36. data/lib/openstudio-standards/prototypes/Prototype.primary_school.rb +230 -213
  37. data/lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb +225 -218
  38. data/lib/openstudio-standards/prototypes/Prototype.retail_standalone.rb +29 -17
  39. data/lib/openstudio-standards/prototypes/Prototype.retail_stripmall.rb +42 -32
  40. data/lib/openstudio-standards/prototypes/Prototype.secondary_school.rb +331 -314
  41. data/lib/openstudio-standards/prototypes/Prototype.small_hotel.rb +233 -219
  42. data/lib/openstudio-standards/prototypes/Prototype.small_office.rb +40 -32
  43. data/lib/openstudio-standards/prototypes/Prototype.warehouse.rb +19 -6
  44. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +576 -555
  45. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +3 -1
  46. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +35 -17
  47. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +51 -23
  48. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +255 -0
  49. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +192 -0
  50. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +65 -0
  51. data/lib/openstudio-standards/standards/Standards.Fan.rb +37 -6
  52. data/lib/openstudio-standards/standards/Standards.Model.rb +28 -3
  53. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +3 -1
  54. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +41 -15
  55. data/lib/openstudio-standards/version.rb +1 -1
  56. data/lib/openstudio-standards/weather/Weather.Model.rb +509 -5
  57. data/lib/openstudio-standards/weather/Weather.stat_file.rb +145 -5
  58. metadata +8 -3
  59. data/lib/openstudio-standards/btap/environment.rb +0 -718
@@ -4,11 +4,11 @@
4
4
  "template": "NECB 2011",
5
5
  "cooling_type": "AirCooled",
6
6
  "subcategory": "Single Package",
7
- "minimum_capacity": "-",
7
+ "minimum_capacity": 0.0,
8
8
  "maximum_capacity": 65000.0,
9
- "minimum_seasonal_efficiency": null,
9
+ "minimum_heating_seasonal_performance_factor": null,
10
+ "minimum_coefficient_of_performance_heating": null,
10
11
  "minimum_energy_efficiency_ratio": 8.9,
11
- "minimum_iplv": null,
12
12
  "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
13
13
  "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
14
14
  "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
@@ -20,11 +20,11 @@
20
20
  "template": "NECB 2011",
21
21
  "cooling_type": "AirCooled",
22
22
  "subcategory": "Split System",
23
- "minimum_capacity": "-",
23
+ "minimum_capacity": 0.0,
24
24
  "maximum_capacity": 65000.0,
25
- "minimum_seasonal_efficiency": null,
25
+ "minimum_heating_seasonal_performance_factor": null,
26
+ "minimum_coefficient_of_performance_heating": null,
26
27
  "minimum_energy_efficiency_ratio": 8.9,
27
- "minimum_iplv": null,
28
28
  "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
29
29
  "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
30
30
  "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
@@ -38,9 +38,9 @@
38
38
  "subcategory": "Single Package",
39
39
  "minimum_capacity": 65001.0,
40
40
  "maximum_capacity": 238840.0,
41
- "minimum_seasonal_efficiency": null,
41
+ "minimum_heating_seasonal_performance_factor": null,
42
+ "minimum_coefficient_of_performance_heating": null,
42
43
  "minimum_energy_efficiency_ratio": 9.5,
43
- "minimum_iplv": null,
44
44
  "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
45
45
  "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
46
46
  "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
@@ -54,9 +54,9 @@
54
54
  "subcategory": "Split System",
55
55
  "minimum_capacity": 65001.0,
56
56
  "maximum_capacity": 238840.0,
57
- "minimum_seasonal_efficiency": null,
57
+ "minimum_heating_seasonal_performance_factor": null,
58
+ "minimum_coefficient_of_performance_heating": null,
58
59
  "minimum_energy_efficiency_ratio": 9.5,
59
- "minimum_iplv": null,
60
60
  "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
61
61
  "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
62
62
  "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
@@ -70,9 +70,9 @@
70
70
  "subcategory": "Single Package",
71
71
  "minimum_capacity": 238841.0,
72
72
  "maximum_capacity": 9999999.0,
73
- "minimum_seasonal_efficiency": null,
73
+ "minimum_heating_seasonal_performance_factor": null,
74
+ "minimum_coefficient_of_performance_heating": null,
74
75
  "minimum_energy_efficiency_ratio": 9.2,
75
- "minimum_iplv": null,
76
76
  "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
77
77
  "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
78
78
  "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
@@ -86,15 +86,767 @@
86
86
  "subcategory": "Split System",
87
87
  "minimum_capacity": 238841.0,
88
88
  "maximum_capacity": 9999999.0,
89
- "minimum_seasonal_efficiency": null,
89
+ "minimum_heating_seasonal_performance_factor": null,
90
+ "minimum_coefficient_of_performance_heating": null,
90
91
  "minimum_energy_efficiency_ratio": 9.2,
91
- "minimum_iplv": null,
92
92
  "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
93
93
  "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
94
94
  "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
95
95
  "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
96
96
  "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
97
97
  "notes": "From NECB 2011, Table 5.2.12.1"
98
+ },
99
+ {
100
+ "template": "DOE Ref Pre-1980",
101
+ "cooling_type": "AirCooled",
102
+ "subcategory": "Split System",
103
+ "minimum_capacity": 0.0,
104
+ "maximum_capacity": 64999.0,
105
+ "minimum_heating_seasonal_performance_factor": 6.8,
106
+ "minimum_coefficient_of_performance_heating": null,
107
+ "minimum_energy_efficiency_ratio": null,
108
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
109
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
110
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
111
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
112
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
113
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
114
+ },
115
+ {
116
+ "template": "DOE Ref Pre-1980",
117
+ "cooling_type": "AirCooled",
118
+ "subcategory": "Single Package",
119
+ "minimum_capacity": 0.0,
120
+ "maximum_capacity": 64999.0,
121
+ "minimum_heating_seasonal_performance_factor": 6.6,
122
+ "minimum_coefficient_of_performance_heating": null,
123
+ "minimum_energy_efficiency_ratio": null,
124
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
125
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
126
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
127
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
128
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
129
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
130
+ },
131
+ {
132
+ "template": "DOE Ref Pre-1980",
133
+ "cooling_type": "ThroughWall",
134
+ "subcategory": "Split System",
135
+ "minimum_capacity": 0.0,
136
+ "maximum_capacity": 29999.0,
137
+ "minimum_heating_seasonal_performance_factor": 6.8,
138
+ "minimum_coefficient_of_performance_heating": null,
139
+ "minimum_energy_efficiency_ratio": null,
140
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
141
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
142
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
143
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
144
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
145
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
146
+ },
147
+ {
148
+ "template": "DOE Ref Pre-1980",
149
+ "cooling_type": "ThroughWall",
150
+ "subcategory": "Single Package",
151
+ "minimum_capacity": 0.0,
152
+ "maximum_capacity": 29999.0,
153
+ "minimum_heating_seasonal_performance_factor": 6.6,
154
+ "minimum_coefficient_of_performance_heating": null,
155
+ "minimum_energy_efficiency_ratio": null,
156
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
157
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
158
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
159
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
160
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
161
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
162
+ },
163
+ {
164
+ "template": "DOE Ref Pre-1980",
165
+ "cooling_type": "SmallDuctHighVelocity",
166
+ "subcategory": "Split System",
167
+ "minimum_capacity": 0.0,
168
+ "maximum_capacity": 64999.0,
169
+ "minimum_heating_seasonal_performance_factor": 6.8,
170
+ "minimum_coefficient_of_performance_heating": null,
171
+ "minimum_energy_efficiency_ratio": null,
172
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
173
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
174
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
175
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
176
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
177
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
178
+ },
179
+ {
180
+ "template": "DOE Ref Pre-1980",
181
+ "cooling_type": "AirCooled",
182
+ "subcategory": "Single Package",
183
+ "minimum_capacity": 65000.0,
184
+ "maximum_capacity": 134999.0,
185
+ "minimum_heating_seasonal_performance_factor": null,
186
+ "minimum_coefficient_of_performance_heating": 3.2,
187
+ "minimum_energy_efficiency_ratio": null,
188
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
189
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
190
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
191
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
192
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
193
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
194
+ },
195
+ {
196
+ "template": "DOE Ref Pre-1980",
197
+ "cooling_type": "AirCooled",
198
+ "subcategory": "Single Package",
199
+ "minimum_capacity": 135000.0,
200
+ "maximum_capacity": 9999999.0,
201
+ "minimum_heating_seasonal_performance_factor": null,
202
+ "minimum_coefficient_of_performance_heating": 3.1,
203
+ "minimum_energy_efficiency_ratio": null,
204
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
205
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
206
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
207
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
208
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
209
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
210
+ },
211
+ {
212
+ "template": "DOE Ref 1980-2004",
213
+ "cooling_type": "AirCooled",
214
+ "subcategory": "Split System",
215
+ "minimum_capacity": 0.0,
216
+ "maximum_capacity": 64999.0,
217
+ "minimum_heating_seasonal_performance_factor": 6.8,
218
+ "minimum_coefficient_of_performance_heating": null,
219
+ "minimum_energy_efficiency_ratio": null,
220
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
221
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
222
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
223
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
224
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
225
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
226
+ },
227
+ {
228
+ "template": "DOE Ref 1980-2004",
229
+ "cooling_type": "AirCooled",
230
+ "subcategory": "Single Package",
231
+ "minimum_capacity": 0.0,
232
+ "maximum_capacity": 64999.0,
233
+ "minimum_heating_seasonal_performance_factor": 6.6,
234
+ "minimum_coefficient_of_performance_heating": null,
235
+ "minimum_energy_efficiency_ratio": null,
236
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
237
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
238
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
239
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
240
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
241
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
242
+ },
243
+ {
244
+ "template": "DOE Ref 1980-2004",
245
+ "cooling_type": "ThroughWall",
246
+ "subcategory": "Split System",
247
+ "minimum_capacity": 0.0,
248
+ "maximum_capacity": 29999.0,
249
+ "minimum_heating_seasonal_performance_factor": 6.8,
250
+ "minimum_coefficient_of_performance_heating": null,
251
+ "minimum_energy_efficiency_ratio": null,
252
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
253
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
254
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
255
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
256
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
257
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
258
+ },
259
+ {
260
+ "template": "DOE Ref 1980-2004",
261
+ "cooling_type": "ThroughWall",
262
+ "subcategory": "Single Package",
263
+ "minimum_capacity": 0.0,
264
+ "maximum_capacity": 29999.0,
265
+ "minimum_heating_seasonal_performance_factor": 6.6,
266
+ "minimum_coefficient_of_performance_heating": null,
267
+ "minimum_energy_efficiency_ratio": null,
268
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
269
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
270
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
271
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
272
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
273
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
274
+ },
275
+ {
276
+ "template": "DOE Ref 1980-2004",
277
+ "cooling_type": "SmallDuctHighVelocity",
278
+ "subcategory": "Split System",
279
+ "minimum_capacity": 0.0,
280
+ "maximum_capacity": 64999.0,
281
+ "minimum_heating_seasonal_performance_factor": 6.8,
282
+ "minimum_coefficient_of_performance_heating": null,
283
+ "minimum_energy_efficiency_ratio": null,
284
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
285
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
286
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
287
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
288
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
289
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
290
+ },
291
+ {
292
+ "template": "DOE Ref 1980-2004",
293
+ "cooling_type": "AirCooled",
294
+ "subcategory": "Single Package",
295
+ "minimum_capacity": 65000.0,
296
+ "maximum_capacity": 134999.0,
297
+ "minimum_heating_seasonal_performance_factor": null,
298
+ "minimum_coefficient_of_performance_heating": 3.2,
299
+ "minimum_energy_efficiency_ratio": null,
300
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
301
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
302
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
303
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
304
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
305
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
306
+ },
307
+ {
308
+ "template": "DOE Ref 1980-2004",
309
+ "cooling_type": "AirCooled",
310
+ "subcategory": "Single Package",
311
+ "minimum_capacity": 135000.0,
312
+ "maximum_capacity": 9999999.0,
313
+ "minimum_heating_seasonal_performance_factor": null,
314
+ "minimum_coefficient_of_performance_heating": 3.1,
315
+ "minimum_energy_efficiency_ratio": null,
316
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
317
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
318
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
319
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
320
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
321
+ "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
322
+ },
323
+ {
324
+ "template": "90.1-2004",
325
+ "cooling_type": "AirCooled",
326
+ "subcategory": "Split System",
327
+ "minimum_capacity": 0.0,
328
+ "maximum_capacity": 64999.0,
329
+ "minimum_heating_seasonal_performance_factor": 6.8,
330
+ "minimum_coefficient_of_performance_heating": null,
331
+ "minimum_energy_efficiency_ratio": null,
332
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
333
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
334
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
335
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
336
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
337
+ "notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
338
+ },
339
+ {
340
+ "template": "90.1-2004",
341
+ "cooling_type": "AirCooled",
342
+ "subcategory": "Single Package",
343
+ "minimum_capacity": 0.0,
344
+ "maximum_capacity": 64999.0,
345
+ "minimum_heating_seasonal_performance_factor": 6.6,
346
+ "minimum_coefficient_of_performance_heating": null,
347
+ "minimum_energy_efficiency_ratio": null,
348
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
349
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
350
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
351
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
352
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
353
+ "notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
354
+ },
355
+ {
356
+ "template": "90.1-2004",
357
+ "cooling_type": "ThroughWall",
358
+ "subcategory": "Split System",
359
+ "minimum_capacity": 0.0,
360
+ "maximum_capacity": 29999.0,
361
+ "minimum_heating_seasonal_performance_factor": 6.8,
362
+ "minimum_coefficient_of_performance_heating": null,
363
+ "minimum_energy_efficiency_ratio": null,
364
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
365
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
366
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
367
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
368
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
369
+ "notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
370
+ },
371
+ {
372
+ "template": "90.1-2004",
373
+ "cooling_type": "ThroughWall",
374
+ "subcategory": "Single Package",
375
+ "minimum_capacity": 0.0,
376
+ "maximum_capacity": 29999.0,
377
+ "minimum_heating_seasonal_performance_factor": 6.6,
378
+ "minimum_coefficient_of_performance_heating": null,
379
+ "minimum_energy_efficiency_ratio": null,
380
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
381
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
382
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
383
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
384
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
385
+ "notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
386
+ },
387
+ {
388
+ "template": "90.1-2004",
389
+ "cooling_type": "SmallDuctHighVelocity",
390
+ "subcategory": "Split System",
391
+ "minimum_capacity": 0.0,
392
+ "maximum_capacity": 64999.0,
393
+ "minimum_heating_seasonal_performance_factor": 6.8,
394
+ "minimum_coefficient_of_performance_heating": null,
395
+ "minimum_energy_efficiency_ratio": null,
396
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
397
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
398
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
399
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
400
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
401
+ "notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
402
+ },
403
+ {
404
+ "template": "90.1-2004",
405
+ "cooling_type": "AirCooled",
406
+ "subcategory": "Single Package",
407
+ "minimum_capacity": 65000.0,
408
+ "maximum_capacity": 134999.0,
409
+ "minimum_heating_seasonal_performance_factor": null,
410
+ "minimum_coefficient_of_performance_heating": 3.2,
411
+ "minimum_energy_efficiency_ratio": null,
412
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
413
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
414
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
415
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
416
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
417
+ "notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
418
+ },
419
+ {
420
+ "template": "90.1-2004",
421
+ "cooling_type": "AirCooled",
422
+ "subcategory": "Single Package",
423
+ "minimum_capacity": 135000.0,
424
+ "maximum_capacity": 9999999.0,
425
+ "minimum_heating_seasonal_performance_factor": null,
426
+ "minimum_coefficient_of_performance_heating": 3.1,
427
+ "minimum_energy_efficiency_ratio": null,
428
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
429
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
430
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
431
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
432
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
433
+ "notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
434
+ },
435
+ {
436
+ "template": "90.1-2007",
437
+ "cooling_type": "AirCooled",
438
+ "subcategory": "Split System",
439
+ "minimum_capacity": 0.0,
440
+ "maximum_capacity": 64999.0,
441
+ "minimum_heating_seasonal_performance_factor": 7.7,
442
+ "minimum_coefficient_of_performance_heating": null,
443
+ "minimum_energy_efficiency_ratio": null,
444
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
445
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
446
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
447
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
448
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
449
+ "notes": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006"
450
+ },
451
+ {
452
+ "template": "90.1-2007",
453
+ "cooling_type": "AirCooled",
454
+ "subcategory": "Single Package",
455
+ "minimum_capacity": 0.0,
456
+ "maximum_capacity": 64999.0,
457
+ "minimum_heating_seasonal_performance_factor": 7.7,
458
+ "minimum_coefficient_of_performance_heating": null,
459
+ "minimum_energy_efficiency_ratio": null,
460
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
461
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
462
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
463
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
464
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
465
+ "notes": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006"
466
+ },
467
+ {
468
+ "template": "90.1-2007",
469
+ "cooling_type": "ThroughWall",
470
+ "subcategory": "Split System",
471
+ "minimum_capacity": 0.0,
472
+ "maximum_capacity": 29999.0,
473
+ "minimum_heating_seasonal_performance_factor": 7.1,
474
+ "minimum_coefficient_of_performance_heating": null,
475
+ "minimum_energy_efficiency_ratio": null,
476
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
477
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
478
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
479
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
480
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
481
+ "notes": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006"
482
+ },
483
+ {
484
+ "template": "90.1-2007",
485
+ "cooling_type": "ThroughWall",
486
+ "subcategory": "Single Package",
487
+ "minimum_capacity": 0.0,
488
+ "maximum_capacity": 29999.0,
489
+ "minimum_heating_seasonal_performance_factor": 7.0,
490
+ "minimum_coefficient_of_performance_heating": null,
491
+ "minimum_energy_efficiency_ratio": null,
492
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
493
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
494
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
495
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
496
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
497
+ "notes": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006"
498
+ },
499
+ {
500
+ "template": "90.1-2007",
501
+ "cooling_type": "AirCooled",
502
+ "subcategory": "Single Package",
503
+ "minimum_capacity": 65000.0,
504
+ "maximum_capacity": 134999.0,
505
+ "minimum_heating_seasonal_performance_factor": null,
506
+ "minimum_coefficient_of_performance_heating": 3.2,
507
+ "minimum_energy_efficiency_ratio": null,
508
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
509
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
510
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
511
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
512
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
513
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
514
+ },
515
+ {
516
+ "template": "90.1-2007",
517
+ "cooling_type": "AirCooled",
518
+ "subcategory": "Single Package",
519
+ "minimum_capacity": 135000.0,
520
+ "maximum_capacity": 9999999.0,
521
+ "minimum_heating_seasonal_performance_factor": null,
522
+ "minimum_coefficient_of_performance_heating": 3.1,
523
+ "minimum_energy_efficiency_ratio": null,
524
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
525
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
526
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
527
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
528
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
529
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
530
+ },
531
+ {
532
+ "template": "90.1-2010",
533
+ "cooling_type": "AirCooled",
534
+ "subcategory": "Split System",
535
+ "minimum_capacity": 0.0,
536
+ "maximum_capacity": 64999.0,
537
+ "minimum_heating_seasonal_performance_factor": 7.7,
538
+ "minimum_coefficient_of_performance_heating": null,
539
+ "minimum_energy_efficiency_ratio": null,
540
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
541
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
542
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
543
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
544
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
545
+ "notes": "From 90.1-2010 Table 6.8.1B"
546
+ },
547
+ {
548
+ "template": "90.1-2010",
549
+ "cooling_type": "AirCooled",
550
+ "subcategory": "Single Package",
551
+ "minimum_capacity": 0.0,
552
+ "maximum_capacity": 64999.0,
553
+ "minimum_heating_seasonal_performance_factor": 7.7,
554
+ "minimum_coefficient_of_performance_heating": null,
555
+ "minimum_energy_efficiency_ratio": null,
556
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
557
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
558
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
559
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
560
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
561
+ "notes": "From 90.1-2010 Table 6.8.1B"
562
+ },
563
+ {
564
+ "template": "90.1-2010",
565
+ "cooling_type": "ThroughWall",
566
+ "subcategory": "Split System",
567
+ "minimum_capacity": 0.0,
568
+ "maximum_capacity": 29999.0,
569
+ "minimum_heating_seasonal_performance_factor": 7.4,
570
+ "minimum_coefficient_of_performance_heating": null,
571
+ "minimum_energy_efficiency_ratio": null,
572
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
573
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
574
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
575
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
576
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
577
+ "notes": "From 90.1-2010 Table 6.8.1B"
578
+ },
579
+ {
580
+ "template": "90.1-2010",
581
+ "cooling_type": "ThroughWall",
582
+ "subcategory": "Single Package",
583
+ "minimum_capacity": 0.0,
584
+ "maximum_capacity": 29999.0,
585
+ "minimum_heating_seasonal_performance_factor": 7.4,
586
+ "minimum_coefficient_of_performance_heating": null,
587
+ "minimum_energy_efficiency_ratio": null,
588
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
589
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
590
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
591
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
592
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
593
+ "notes": "From 90.1-2010 Table 6.8.1B"
594
+ },
595
+ {
596
+ "template": "90.1-2010",
597
+ "cooling_type": "AirCooled",
598
+ "subcategory": "Single Package",
599
+ "minimum_capacity": 65000.0,
600
+ "maximum_capacity": 134999.0,
601
+ "minimum_heating_seasonal_performance_factor": null,
602
+ "minimum_coefficient_of_performance_heating": 3.3,
603
+ "minimum_energy_efficiency_ratio": null,
604
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
605
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
606
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
607
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
608
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
609
+ "notes": "From 90.1-2010 Table 6.8.1B"
610
+ },
611
+ {
612
+ "template": "90.1-2010",
613
+ "cooling_type": "AirCooled",
614
+ "subcategory": "Single Package",
615
+ "minimum_capacity": 135000.0,
616
+ "maximum_capacity": 9999999.0,
617
+ "minimum_heating_seasonal_performance_factor": null,
618
+ "minimum_coefficient_of_performance_heating": 3.2,
619
+ "minimum_energy_efficiency_ratio": null,
620
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
621
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
622
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
623
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
624
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
625
+ "notes": "From 90.1-2010 Table 6.8.1B"
626
+ },
627
+ {
628
+ "template": "90.1-2013",
629
+ "cooling_type": "AirCooled",
630
+ "subcategory": "Split System",
631
+ "minimum_capacity": 0.0,
632
+ "maximum_capacity": 64999.0,
633
+ "minimum_heating_seasonal_performance_factor": 7.7,
634
+ "minimum_coefficient_of_performance_heating": null,
635
+ "minimum_energy_efficiency_ratio": null,
636
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
637
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
638
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
639
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
640
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
641
+ "notes": "From 90.1-2013 Table 6.8.1-2, Before 1/1/2015"
642
+ },
643
+ {
644
+ "template": "90.1-2013",
645
+ "cooling_type": "AirCooled",
646
+ "subcategory": "Single Package",
647
+ "minimum_capacity": 0.0,
648
+ "maximum_capacity": 64999.0,
649
+ "minimum_heating_seasonal_performance_factor": 7.7,
650
+ "minimum_coefficient_of_performance_heating": null,
651
+ "minimum_energy_efficiency_ratio": null,
652
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
653
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
654
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
655
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
656
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
657
+ "notes": "From 90.1-2013 Table 6.8.1-2, Before 1/1/2015"
658
+ },
659
+ {
660
+ "template": "90.1-2013",
661
+ "cooling_type": "ThroughWall",
662
+ "subcategory": "Split System",
663
+ "minimum_capacity": 0.0,
664
+ "maximum_capacity": 29999.0,
665
+ "minimum_heating_seasonal_performance_factor": 7.4,
666
+ "minimum_coefficient_of_performance_heating": null,
667
+ "minimum_energy_efficiency_ratio": null,
668
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
669
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
670
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
671
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
672
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
673
+ "notes": "From 90.1-2013 Table 6.8.1-2"
674
+ },
675
+ {
676
+ "template": "90.1-2013",
677
+ "cooling_type": "ThroughWall",
678
+ "subcategory": "Single Package",
679
+ "minimum_capacity": 0.0,
680
+ "maximum_capacity": 29999.0,
681
+ "minimum_heating_seasonal_performance_factor": 7.4,
682
+ "minimum_coefficient_of_performance_heating": null,
683
+ "minimum_energy_efficiency_ratio": null,
684
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
685
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
686
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
687
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
688
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
689
+ "notes": "From 90.1-2013 Table 6.8.1-3"
690
+ },
691
+ {
692
+ "template": "90.1-2013",
693
+ "cooling_type": "SmallDuctHighVelocity",
694
+ "subcategory": "Split System",
695
+ "minimum_capacity": 0.0,
696
+ "maximum_capacity": 64999.0,
697
+ "minimum_heating_seasonal_performance_factor": 6.8,
698
+ "minimum_coefficient_of_performance_heating": null,
699
+ "minimum_energy_efficiency_ratio": null,
700
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
701
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
702
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
703
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
704
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
705
+ "notes": "From 90.1-2013 Table 6.8.1-4"
706
+ },
707
+ {
708
+ "template": "90.1-2013",
709
+ "cooling_type": "AirCooled",
710
+ "subcategory": "Single Package",
711
+ "minimum_capacity": 65000.0,
712
+ "maximum_capacity": 134999.0,
713
+ "minimum_heating_seasonal_performance_factor": null,
714
+ "minimum_coefficient_of_performance_heating": 3.3,
715
+ "minimum_energy_efficiency_ratio": null,
716
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
717
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
718
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
719
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
720
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
721
+ "notes": "From 90.1-2013 Table 6.8.1-5"
722
+ },
723
+ {
724
+ "template": "90.1-2013",
725
+ "cooling_type": "AirCooled",
726
+ "subcategory": "Single Package",
727
+ "minimum_capacity": 135000.0,
728
+ "maximum_capacity": 9999999.0,
729
+ "minimum_heating_seasonal_performance_factor": null,
730
+ "minimum_coefficient_of_performance_heating": 3.2,
731
+ "minimum_energy_efficiency_ratio": null,
732
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
733
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
734
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
735
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
736
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
737
+ "notes": "From 90.1-2013 Table 6.8.1-6"
738
+ },
739
+ {
740
+ "template": "OEESC 2014",
741
+ "cooling_type": "AirCooled",
742
+ "subcategory": "Split System",
743
+ "minimum_capacity": 0.0,
744
+ "maximum_capacity": 64999.0,
745
+ "minimum_heating_seasonal_performance_factor": 8.2,
746
+ "minimum_coefficient_of_performance_heating": null,
747
+ "minimum_energy_efficiency_ratio": null,
748
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
749
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
750
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
751
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
752
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
753
+ "notes": "From OEESC2014 Table 503.2.3(2) Before 1/1/2016"
754
+ },
755
+ {
756
+ "template": "OEESC 2014",
757
+ "cooling_type": "AirCooled",
758
+ "subcategory": "Single Package",
759
+ "minimum_capacity": 0.0,
760
+ "maximum_capacity": 64999.0,
761
+ "minimum_heating_seasonal_performance_factor": 8.0,
762
+ "minimum_coefficient_of_performance_heating": null,
763
+ "minimum_energy_efficiency_ratio": null,
764
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
765
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
766
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
767
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
768
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
769
+ "notes": "From OEESC2014 Table 503.2.3(2) Before 1/1/2016"
770
+ },
771
+ {
772
+ "template": "OEESC 2014",
773
+ "cooling_type": "ThroughWall",
774
+ "subcategory": "Split System",
775
+ "minimum_capacity": 0.0,
776
+ "maximum_capacity": 29999.0,
777
+ "minimum_heating_seasonal_performance_factor": 7.4,
778
+ "minimum_coefficient_of_performance_heating": null,
779
+ "minimum_energy_efficiency_ratio": null,
780
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
781
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
782
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
783
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
784
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
785
+ "notes": "From OEESC2014 Table 503.2.3(2) Before 1/1/2016"
786
+ },
787
+ {
788
+ "template": "OEESC 2014",
789
+ "cooling_type": "ThroughWall",
790
+ "subcategory": "Single Package",
791
+ "minimum_capacity": 0.0,
792
+ "maximum_capacity": 29999.0,
793
+ "minimum_heating_seasonal_performance_factor": 7.4,
794
+ "minimum_coefficient_of_performance_heating": null,
795
+ "minimum_energy_efficiency_ratio": null,
796
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
797
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
798
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
799
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
800
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
801
+ "notes": "From OEESC2014 Table 503.2.3(2) Before 1/1/2016"
802
+ },
803
+ {
804
+ "template": "OEESC 2014",
805
+ "cooling_type": "SmallDuctHighVelocity",
806
+ "subcategory": "Split System",
807
+ "minimum_capacity": 0.0,
808
+ "maximum_capacity": 64999.0,
809
+ "minimum_heating_seasonal_performance_factor": 6.8,
810
+ "minimum_coefficient_of_performance_heating": null,
811
+ "minimum_energy_efficiency_ratio": null,
812
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
813
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
814
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
815
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
816
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
817
+ "notes": "From OEESC2014 Table 503.2.3(2) Before 1/1/2016"
818
+ },
819
+ {
820
+ "template": "OEESC 2014",
821
+ "cooling_type": "AirCooled",
822
+ "subcategory": "Single Package",
823
+ "minimum_capacity": 65000.0,
824
+ "maximum_capacity": 134999.0,
825
+ "minimum_heating_seasonal_performance_factor": null,
826
+ "minimum_coefficient_of_performance_heating": 3.3,
827
+ "minimum_energy_efficiency_ratio": null,
828
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
829
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
830
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
831
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
832
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
833
+ "notes": "From OEESC2014 Table 503.2.3(2) Before 1/1/2016"
834
+ },
835
+ {
836
+ "template": "OEESC 2014",
837
+ "cooling_type": "AirCooled",
838
+ "subcategory": "Single Package",
839
+ "minimum_capacity": 135000.0,
840
+ "maximum_capacity": 9999999.0,
841
+ "minimum_heating_seasonal_performance_factor": null,
842
+ "minimum_coefficient_of_performance_heating": 3.2,
843
+ "minimum_energy_efficiency_ratio": null,
844
+ "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT",
845
+ "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
846
+ "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
847
+ "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
848
+ "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
849
+ "notes": "From OEESC2014 Table 503.2.3(2) Before 1/1/2016"
98
850
  }
99
851
  ]
100