openstudio-standards 0.1.3 → 0.1.4

Sign up to get free protection for your applications and to get access to all the features.
Files changed (59) hide show
  1. checksums.yaml +4 -4
  2. data/data/standards/OpenStudio_Standards.xlsx +0 -0
  3. data/data/standards/OpenStudio_Standards_chillers.json +5 -5
  4. data/data/standards/OpenStudio_Standards_construction_sets.json +2 -2
  5. data/data/standards/OpenStudio_Standards_curve_cubics.json +12 -0
  6. data/data/standards/OpenStudio_Standards_heat_pumps.json +2126 -72
  7. data/data/standards/OpenStudio_Standards_heat_pumps_heating.json +766 -14
  8. data/data/standards/OpenStudio_Standards_heat_rejection.json +172 -0
  9. data/data/standards/OpenStudio_Standards_prototype_inputs.json +355 -267
  10. data/data/standards/OpenStudio_Standards_schedules.json +262 -10
  11. data/data/standards/OpenStudio_Standards_space_types.json +1466 -794
  12. data/data/standards/manage_OpenStudio_Standards.rb +19 -21
  13. data/data/weather/weather_info.csv +96 -0
  14. data/lib/openstudio-standards/btap/btap.rb +1 -1
  15. data/lib/openstudio-standards/btap/compliance.rb +135 -40
  16. data/lib/openstudio-standards/btap/envelope.rb +26 -5
  17. data/lib/openstudio-standards/btap/geometry.rb +11 -1
  18. data/lib/openstudio-standards/btap/hvac.rb +489 -56
  19. data/lib/openstudio-standards/btap/simmanager.rb +1 -1
  20. data/lib/openstudio-standards/hvac_sizing/HVACSizing.CoilHeatingDXMultiSpeed.rb +120 -0
  21. data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingDXMultiSpeed.rb +151 -7
  22. data/lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingGasMultiStage.rb +48 -7
  23. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +14 -12
  24. data/lib/openstudio-standards/prototypes/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -7
  25. data/lib/openstudio-standards/prototypes/Prototype.Model.hvac.rb +123 -91
  26. data/lib/openstudio-standards/prototypes/Prototype.Model.rb +130 -45
  27. data/lib/openstudio-standards/prototypes/Prototype.Model.swh.rb +13 -7
  28. data/lib/openstudio-standards/prototypes/Prototype.full_service_restaurant.rb +332 -324
  29. data/lib/openstudio-standards/prototypes/Prototype.hospital.rb +401 -99
  30. data/lib/openstudio-standards/prototypes/Prototype.hvac_systems.rb +309 -222
  31. data/lib/openstudio-standards/prototypes/Prototype.large_hotel.rb +100 -80
  32. data/lib/openstudio-standards/prototypes/Prototype.large_office.rb +37 -22
  33. data/lib/openstudio-standards/prototypes/Prototype.medium_office.rb +68 -53
  34. data/lib/openstudio-standards/prototypes/Prototype.mid_rise_apartment.rb +109 -88
  35. data/lib/openstudio-standards/prototypes/Prototype.outpatient.rb +52 -4
  36. data/lib/openstudio-standards/prototypes/Prototype.primary_school.rb +230 -213
  37. data/lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb +225 -218
  38. data/lib/openstudio-standards/prototypes/Prototype.retail_standalone.rb +29 -17
  39. data/lib/openstudio-standards/prototypes/Prototype.retail_stripmall.rb +42 -32
  40. data/lib/openstudio-standards/prototypes/Prototype.secondary_school.rb +331 -314
  41. data/lib/openstudio-standards/prototypes/Prototype.small_hotel.rb +233 -219
  42. data/lib/openstudio-standards/prototypes/Prototype.small_office.rb +40 -32
  43. data/lib/openstudio-standards/prototypes/Prototype.warehouse.rb +19 -6
  44. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +576 -555
  45. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +3 -1
  46. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +35 -17
  47. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +51 -23
  48. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +255 -0
  49. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +192 -0
  50. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +65 -0
  51. data/lib/openstudio-standards/standards/Standards.Fan.rb +37 -6
  52. data/lib/openstudio-standards/standards/Standards.Model.rb +28 -3
  53. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +3 -1
  54. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +41 -15
  55. data/lib/openstudio-standards/version.rb +1 -1
  56. data/lib/openstudio-standards/weather/Weather.Model.rb +509 -5
  57. data/lib/openstudio-standards/weather/Weather.stat_file.rb +145 -5
  58. metadata +8 -3
  59. data/lib/openstudio-standards/btap/environment.rb +0 -718
checksums.yaml CHANGED
@@ -1,7 +1,7 @@
1
1
  ---
2
2
  SHA1:
3
- metadata.gz: 3b528f4fbfe4f287e792b723a0eca90ab045cd22
4
- data.tar.gz: 8a5d326de020f16dc1803900c901cdbfbd94b289
3
+ metadata.gz: b164bdb48d7e7d6fc4b9ca722b6dc98bdd472add
4
+ data.tar.gz: 84460c4c20503fe84ab53b0d3a148c4473c90033
5
5
  SHA512:
6
- metadata.gz: 993958fe7f17a8ee6ec9d5a853889965a39787e7d76fe198773da1d054bc8440712cbb5b938f1c7bff23d73a00ee59112811f18bdc8fd6f236f2a023cde4d324
7
- data.tar.gz: c7e95e06ca70daafe9aa056ec08ef2a88ce78aee4c4f0d648512979d54c37bfe16f4c35351f6d26bcbb00f3c639ad7f2d1557859ac38b39718183e5d7d069cff
6
+ metadata.gz: 24852edd6486495cd5c7d67fe300c1fc6d2b9021daac50c0ea55e7771e145ae063d1be558445b8706b54da826857c5dbcb23f7a50ed1263e36989d798c30f0cb
7
+ data.tar.gz: 373c8413336635a360f75c1df37ace49cdeab8b57656d0a729d7160efd67eb8317544b8f467696ffdb921edf8f2e0311253848d3168b59bf4d7ff2188e730d60
@@ -207,7 +207,7 @@
207
207
  "minimum_integrated_part_load_value": 0.55,
208
208
  "capft": "WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT",
209
209
  "eirft": "WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT",
210
- "eirfplr": "ChlrWtrCentPathBGtEql600tonEIRRatio_fQRatio",
210
+ "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio",
211
211
  "notes": null
212
212
  },
213
213
  {
@@ -492,7 +492,7 @@
492
492
  "minimum_integrated_part_load_value": 0.549,
493
493
  "capft": "WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT",
494
494
  "eirft": "WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT",
495
- "eirfplr": "ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fQRatio",
495
+ "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio",
496
496
  "notes": "Path A Minimum Efficiencies"
497
497
  },
498
498
  {
@@ -507,7 +507,7 @@
507
507
  "minimum_integrated_part_load_value": 0.539,
508
508
  "capft": "WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT",
509
509
  "eirft": "WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT",
510
- "eirfplr": "ChlrWtrCentPathBGtEql600tonEIRRatio_fQRatio",
510
+ "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio",
511
511
  "notes": "Path A Minimum Efficiencies"
512
512
  },
513
513
  {
@@ -1197,7 +1197,7 @@
1197
1197
  "minimum_integrated_part_load_value": 0.5,
1198
1198
  "capft": "WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT",
1199
1199
  "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT",
1200
- "eirfplr": "ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fQRatio",
1200
+ "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio",
1201
1201
  "notes": null
1202
1202
  },
1203
1203
  {
@@ -1212,7 +1212,7 @@
1212
1212
  "minimum_integrated_part_load_value": 0.5,
1213
1213
  "capft": "WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT",
1214
1214
  "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT",
1215
- "eirfplr": "ChlrWtrCentPathBGtEql600tonEIRRatio_fQRatio",
1215
+ "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio",
1216
1216
  "notes": "Add but unsure what to put for Minimum full load efficiency and min IPLV"
1217
1217
  },
1218
1218
  {
@@ -4967,7 +4967,7 @@
4967
4967
  "space_type": "PatRoom",
4968
4968
  "is_residential": "No",
4969
4969
  "exterior_wall_standards_construction_type": "Mass",
4970
- "exterior_wall_building_category": "Residential",
4970
+ "exterior_wall_building_category": "Nonresidential",
4971
4971
  "exterior_floor_standards_construction_type": "Mass",
4972
4972
  "exterior_floor_building_category": "Residential",
4973
4973
  "exterior_roof_standards_construction_type": "IEAD",
@@ -5910,7 +5910,7 @@
5910
5910
  "space_type": "PatRoom",
5911
5911
  "is_residential": "No",
5912
5912
  "exterior_wall_standards_construction_type": "Mass",
5913
- "exterior_wall_building_category": "Residential",
5913
+ "exterior_wall_building_category": "Nonresidential",
5914
5914
  "exterior_floor_standards_construction_type": "Mass",
5915
5915
  "exterior_floor_building_category": "Residential",
5916
5916
  "exterior_roof_standards_construction_type": "IEAD",
@@ -444,6 +444,18 @@
444
444
  "max_out": null,
445
445
  "notes": "From Prototype Buildings"
446
446
  },
447
+ {
448
+ "name": "VSD-TWR-FAN-FPLR",
449
+ "coeff_1": 0.33162901,
450
+ "coeff_2": -0.88567609,
451
+ "coeff_3": 0.60556507,
452
+ "coeff_4": 0.9484823,
453
+ "min_x": 0.0,
454
+ "max_x": 1.0,
455
+ "min_out": null,
456
+ "max_out": null,
457
+ "notes": "From PNNL PRM Reference Manual"
458
+ },
447
459
  {
448
460
  "name": "VarVolFan-AFBIFanCurve-NECB2011-FPLR",
449
461
  "coeff_1": -2.4176,
@@ -1,83 +1,16 @@
1
1
  {
2
2
  "heat_pumps": [
3
- {
4
- "template": "90.1-2010",
5
- "cooling_type": "AirCooled",
6
- "heating_type": "Electric Resistance or None",
7
- "subcategory": "Split System",
8
- "minimum_capacity": 0.0,
9
- "maximum_capacity": 9999999.0,
10
- "minimum_seasonal_efficiency": 13.0,
11
- "minimum_full_load_efficiency": null,
12
- "minimum_iplv": null,
13
- "cool_cap_ft": "HPACCoolCapFT",
14
- "cool_cap_fflow": "HPACCoolCapFFF",
15
- "cool_eir_ft": "HPACCOOLEIRFT",
16
- "cool_eir_fflow": "HPACCOOLEIRFFF",
17
- "cool_plf_fplr": "HPACCOOLPLFFPLR",
18
- "notes": null
19
- },
20
- {
21
- "template": "90.1-2010",
22
- "cooling_type": "AirCooled",
23
- "heating_type": "All Other",
24
- "subcategory": "Split System",
25
- "minimum_capacity": 0.0,
26
- "maximum_capacity": 9999999.0,
27
- "minimum_seasonal_efficiency": 13.0,
28
- "minimum_full_load_efficiency": null,
29
- "minimum_iplv": null,
30
- "cool_cap_ft": "HPACCoolCapFT",
31
- "cool_cap_fflow": "HPACCoolCapFFF",
32
- "cool_eir_ft": "HPACCOOLEIRFT",
33
- "cool_eir_fflow": "HPACCOOLEIRFFF",
34
- "cool_plf_fplr": "HPACCOOLPLFFPLR",
35
- "notes": null
36
- },
37
- {
38
- "template": "90.1-2010",
39
- "cooling_type": "AirCooled",
40
- "heating_type": "Electric Resistance or None",
41
- "subcategory": "Single Package",
42
- "minimum_capacity": 0.0,
43
- "maximum_capacity": 9999999.0,
44
- "minimum_seasonal_efficiency": 13.0,
45
- "minimum_full_load_efficiency": null,
46
- "minimum_iplv": null,
47
- "cool_cap_ft": "HPACCoolCapFT",
48
- "cool_cap_fflow": "HPACCoolCapFFF",
49
- "cool_eir_ft": "HPACCOOLEIRFT",
50
- "cool_eir_fflow": "HPACCOOLEIRFFF",
51
- "cool_plf_fplr": "HPACCOOLPLFFPLR",
52
- "notes": null
53
- },
54
- {
55
- "template": "90.1-2010",
56
- "cooling_type": "AirCooled",
57
- "heating_type": "All Other",
58
- "subcategory": "Single Package",
59
- "minimum_capacity": 0.0,
60
- "maximum_capacity": 9999999.0,
61
- "minimum_seasonal_efficiency": 13.0,
62
- "minimum_full_load_efficiency": null,
63
- "minimum_iplv": null,
64
- "cool_cap_ft": "HPACCoolCapFT",
65
- "cool_cap_fflow": "HPACCoolCapFFF",
66
- "cool_eir_ft": "HPACCOOLEIRFT",
67
- "cool_eir_fflow": "HPACCOOLEIRFFF",
68
- "cool_plf_fplr": "HPACCOOLPLFFPLR",
69
- "notes": null
70
- },
71
3
  {
72
4
  "template": "NECB 2011",
73
5
  "cooling_type": "AirCooled",
74
6
  "heating_type": "Electric Resistance or None",
75
7
  "subcategory": "Single Package",
76
- "minimum_capacity": "-",
8
+ "minimum_capacity": 0.0,
77
9
  "maximum_capacity": 65000.0,
78
10
  "minimum_seasonal_efficiency": null,
79
11
  "minimum_full_load_efficiency": 10.0,
80
12
  "minimum_iplv": null,
13
+ "minimum_integrated_energy_efficiency_ratio": null,
81
14
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
82
15
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
83
16
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -90,11 +23,12 @@
90
23
  "cooling_type": "AirCooled",
91
24
  "heating_type": "All Other",
92
25
  "subcategory": "Single Package",
93
- "minimum_capacity": "-",
26
+ "minimum_capacity": 0.0,
94
27
  "maximum_capacity": 65000.0,
95
28
  "minimum_seasonal_efficiency": null,
96
29
  "minimum_full_load_efficiency": 10.0,
97
30
  "minimum_iplv": null,
31
+ "minimum_integrated_energy_efficiency_ratio": null,
98
32
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
99
33
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
100
34
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -107,11 +41,12 @@
107
41
  "cooling_type": "AirCooled",
108
42
  "heating_type": "Electric Resistance or None",
109
43
  "subcategory": "Split System",
110
- "minimum_capacity": "-",
44
+ "minimum_capacity": 0.0,
111
45
  "maximum_capacity": 65000.0,
112
46
  "minimum_seasonal_efficiency": null,
113
47
  "minimum_full_load_efficiency": 10.0,
114
48
  "minimum_iplv": null,
49
+ "minimum_integrated_energy_efficiency_ratio": null,
115
50
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
116
51
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
117
52
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -124,11 +59,12 @@
124
59
  "cooling_type": "AirCooled",
125
60
  "heating_type": "All Other",
126
61
  "subcategory": "Split System",
127
- "minimum_capacity": "-",
62
+ "minimum_capacity": 0.0,
128
63
  "maximum_capacity": 65000.0,
129
64
  "minimum_seasonal_efficiency": null,
130
65
  "minimum_full_load_efficiency": 10.0,
131
66
  "minimum_iplv": null,
67
+ "minimum_integrated_energy_efficiency_ratio": null,
132
68
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
133
69
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
134
70
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -146,6 +82,7 @@
146
82
  "minimum_seasonal_efficiency": null,
147
83
  "minimum_full_load_efficiency": 9.26,
148
84
  "minimum_iplv": null,
85
+ "minimum_integrated_energy_efficiency_ratio": null,
149
86
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
150
87
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
151
88
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -163,6 +100,7 @@
163
100
  "minimum_seasonal_efficiency": null,
164
101
  "minimum_full_load_efficiency": 9.08,
165
102
  "minimum_iplv": null,
103
+ "minimum_integrated_energy_efficiency_ratio": null,
166
104
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
167
105
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
168
106
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -180,6 +118,7 @@
180
118
  "minimum_seasonal_efficiency": null,
181
119
  "minimum_full_load_efficiency": 9.26,
182
120
  "minimum_iplv": null,
121
+ "minimum_integrated_energy_efficiency_ratio": null,
183
122
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
184
123
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
185
124
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -197,6 +136,7 @@
197
136
  "minimum_seasonal_efficiency": null,
198
137
  "minimum_full_load_efficiency": 9.08,
199
138
  "minimum_iplv": null,
139
+ "minimum_integrated_energy_efficiency_ratio": null,
200
140
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
201
141
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
202
142
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -214,6 +154,7 @@
214
154
  "minimum_seasonal_efficiency": null,
215
155
  "minimum_full_load_efficiency": 8.9,
216
156
  "minimum_iplv": null,
157
+ "minimum_integrated_energy_efficiency_ratio": null,
217
158
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
218
159
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
219
160
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -231,6 +172,7 @@
231
172
  "minimum_seasonal_efficiency": null,
232
173
  "minimum_full_load_efficiency": 8.72,
233
174
  "minimum_iplv": null,
175
+ "minimum_integrated_energy_efficiency_ratio": null,
234
176
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
235
177
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
236
178
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -248,6 +190,7 @@
248
190
  "minimum_seasonal_efficiency": null,
249
191
  "minimum_full_load_efficiency": 8.9,
250
192
  "minimum_iplv": null,
193
+ "minimum_integrated_energy_efficiency_ratio": null,
251
194
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
252
195
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
253
196
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -265,6 +208,7 @@
265
208
  "minimum_seasonal_efficiency": null,
266
209
  "minimum_full_load_efficiency": 8.72,
267
210
  "minimum_iplv": null,
211
+ "minimum_integrated_energy_efficiency_ratio": null,
268
212
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
269
213
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
270
214
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -282,6 +226,7 @@
282
226
  "minimum_seasonal_efficiency": null,
283
227
  "minimum_full_load_efficiency": 7.94,
284
228
  "minimum_iplv": null,
229
+ "minimum_integrated_energy_efficiency_ratio": null,
285
230
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
286
231
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
287
232
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -299,6 +244,7 @@
299
244
  "minimum_seasonal_efficiency": null,
300
245
  "minimum_full_load_efficiency": 7.76,
301
246
  "minimum_iplv": null,
247
+ "minimum_integrated_energy_efficiency_ratio": null,
302
248
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
303
249
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
304
250
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -316,6 +262,7 @@
316
262
  "minimum_seasonal_efficiency": null,
317
263
  "minimum_full_load_efficiency": 7.94,
318
264
  "minimum_iplv": null,
265
+ "minimum_integrated_energy_efficiency_ratio": null,
319
266
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
320
267
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
321
268
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
@@ -333,12 +280,2119 @@
333
280
  "minimum_seasonal_efficiency": null,
334
281
  "minimum_full_load_efficiency": 7.76,
335
282
  "minimum_iplv": null,
283
+ "minimum_integrated_energy_efficiency_ratio": null,
336
284
  "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT",
337
285
  "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW",
338
286
  "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
339
287
  "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
340
288
  "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
341
289
  "notes": null
290
+ },
291
+ {
292
+ "template": "DOE Ref Pre-1980",
293
+ "cooling_type": "AirCooled",
294
+ "heating_type": null,
295
+ "subcategory": "Split System",
296
+ "minimum_capacity": 0.0,
297
+ "maximum_capacity": 64999.0,
298
+ "minimum_seasonal_efficiency": 10.0,
299
+ "minimum_full_load_efficiency": null,
300
+ "minimum_iplv": null,
301
+ "minimum_integrated_energy_efficiency_ratio": null,
302
+ "cool_cap_ft": "HPACCoolCapFT",
303
+ "cool_cap_fflow": "HPACCoolCapFFF",
304
+ "cool_eir_ft": "HPACCOOLEIRFT",
305
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
306
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
307
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
308
+ },
309
+ {
310
+ "template": "DOE Ref Pre-1980",
311
+ "cooling_type": "AirCooled",
312
+ "heating_type": null,
313
+ "subcategory": "Single Package",
314
+ "minimum_capacity": 0.0,
315
+ "maximum_capacity": 64999.0,
316
+ "minimum_seasonal_efficiency": 9.7,
317
+ "minimum_full_load_efficiency": null,
318
+ "minimum_iplv": null,
319
+ "minimum_integrated_energy_efficiency_ratio": null,
320
+ "cool_cap_ft": "HPACCoolCapFT",
321
+ "cool_cap_fflow": "HPACCoolCapFFF",
322
+ "cool_eir_ft": "HPACCOOLEIRFT",
323
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
324
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
325
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
326
+ },
327
+ {
328
+ "template": "DOE Ref Pre-1980",
329
+ "cooling_type": "ThroughWall",
330
+ "heating_type": null,
331
+ "subcategory": "Split System",
332
+ "minimum_capacity": 0.0,
333
+ "maximum_capacity": 29999.0,
334
+ "minimum_seasonal_efficiency": 10.0,
335
+ "minimum_full_load_efficiency": null,
336
+ "minimum_iplv": null,
337
+ "minimum_integrated_energy_efficiency_ratio": null,
338
+ "cool_cap_ft": "HPACCoolCapFT",
339
+ "cool_cap_fflow": "HPACCoolCapFFF",
340
+ "cool_eir_ft": "HPACCOOLEIRFT",
341
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
342
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
343
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
344
+ },
345
+ {
346
+ "template": "DOE Ref Pre-1980",
347
+ "cooling_type": "ThroughWall",
348
+ "heating_type": null,
349
+ "subcategory": "Single Package",
350
+ "minimum_capacity": 0.0,
351
+ "maximum_capacity": 29999.0,
352
+ "minimum_seasonal_efficiency": 9.7,
353
+ "minimum_full_load_efficiency": null,
354
+ "minimum_iplv": null,
355
+ "minimum_integrated_energy_efficiency_ratio": null,
356
+ "cool_cap_ft": "HPACCoolCapFT",
357
+ "cool_cap_fflow": "HPACCoolCapFFF",
358
+ "cool_eir_ft": "HPACCOOLEIRFT",
359
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
360
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
361
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
362
+ },
363
+ {
364
+ "template": "DOE Ref Pre-1980",
365
+ "cooling_type": "SmallDuctHighVelocity",
366
+ "heating_type": null,
367
+ "subcategory": "Split System",
368
+ "minimum_capacity": 0.0,
369
+ "maximum_capacity": 64999.0,
370
+ "minimum_seasonal_efficiency": 10.0,
371
+ "minimum_full_load_efficiency": null,
372
+ "minimum_iplv": null,
373
+ "minimum_integrated_energy_efficiency_ratio": null,
374
+ "cool_cap_ft": "HPACCoolCapFT",
375
+ "cool_cap_fflow": "HPACCoolCapFFF",
376
+ "cool_eir_ft": "HPACCOOLEIRFT",
377
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
378
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
379
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
380
+ },
381
+ {
382
+ "template": "DOE Ref Pre-1980",
383
+ "cooling_type": "AirCooled",
384
+ "heating_type": "Electric Resistance or None",
385
+ "subcategory": "Split System",
386
+ "minimum_capacity": 65000.0,
387
+ "maximum_capacity": 134999.0,
388
+ "minimum_seasonal_efficiency": null,
389
+ "minimum_full_load_efficiency": 10.1,
390
+ "minimum_iplv": null,
391
+ "minimum_integrated_energy_efficiency_ratio": null,
392
+ "cool_cap_ft": "HPACCoolCapFT",
393
+ "cool_cap_fflow": "HPACCoolCapFFF",
394
+ "cool_eir_ft": "HPACCOOLEIRFT",
395
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
396
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
397
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
398
+ },
399
+ {
400
+ "template": "DOE Ref Pre-1980",
401
+ "cooling_type": "AirCooled",
402
+ "heating_type": "Electric Resistance or None",
403
+ "subcategory": "Single Package",
404
+ "minimum_capacity": 65000.0,
405
+ "maximum_capacity": 134999.0,
406
+ "minimum_seasonal_efficiency": null,
407
+ "minimum_full_load_efficiency": 10.1,
408
+ "minimum_iplv": null,
409
+ "minimum_integrated_energy_efficiency_ratio": null,
410
+ "cool_cap_ft": "HPACCoolCapFT",
411
+ "cool_cap_fflow": "HPACCoolCapFFF",
412
+ "cool_eir_ft": "HPACCOOLEIRFT",
413
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
414
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
415
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
416
+ },
417
+ {
418
+ "template": "DOE Ref Pre-1980",
419
+ "cooling_type": "AirCooled",
420
+ "heating_type": "All Other",
421
+ "subcategory": "Split System",
422
+ "minimum_capacity": 65000.0,
423
+ "maximum_capacity": 134999.0,
424
+ "minimum_seasonal_efficiency": null,
425
+ "minimum_full_load_efficiency": 9.9,
426
+ "minimum_iplv": null,
427
+ "minimum_integrated_energy_efficiency_ratio": null,
428
+ "cool_cap_ft": "HPACCoolCapFT",
429
+ "cool_cap_fflow": "HPACCoolCapFFF",
430
+ "cool_eir_ft": "HPACCOOLEIRFT",
431
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
432
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
433
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
434
+ },
435
+ {
436
+ "template": "DOE Ref Pre-1980",
437
+ "cooling_type": "AirCooled",
438
+ "heating_type": "All Other",
439
+ "subcategory": "Single Package",
440
+ "minimum_capacity": 65000.0,
441
+ "maximum_capacity": 134999.0,
442
+ "minimum_seasonal_efficiency": null,
443
+ "minimum_full_load_efficiency": 9.9,
444
+ "minimum_iplv": null,
445
+ "minimum_integrated_energy_efficiency_ratio": null,
446
+ "cool_cap_ft": "HPACCoolCapFT",
447
+ "cool_cap_fflow": "HPACCoolCapFFF",
448
+ "cool_eir_ft": "HPACCOOLEIRFT",
449
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
450
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
451
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
452
+ },
453
+ {
454
+ "template": "DOE Ref Pre-1980",
455
+ "cooling_type": "AirCooled",
456
+ "heating_type": "Electric Resistance or None",
457
+ "subcategory": "Split System",
458
+ "minimum_capacity": 135000.0,
459
+ "maximum_capacity": 239999.0,
460
+ "minimum_seasonal_efficiency": null,
461
+ "minimum_full_load_efficiency": 9.3,
462
+ "minimum_iplv": null,
463
+ "minimum_integrated_energy_efficiency_ratio": null,
464
+ "cool_cap_ft": "HPACCoolCapFT",
465
+ "cool_cap_fflow": "HPACCoolCapFFF",
466
+ "cool_eir_ft": "HPACCOOLEIRFT",
467
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
468
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
469
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
470
+ },
471
+ {
472
+ "template": "DOE Ref Pre-1980",
473
+ "cooling_type": "AirCooled",
474
+ "heating_type": "Electric Resistance or None",
475
+ "subcategory": "Single Package",
476
+ "minimum_capacity": 135000.0,
477
+ "maximum_capacity": 239999.0,
478
+ "minimum_seasonal_efficiency": null,
479
+ "minimum_full_load_efficiency": 9.3,
480
+ "minimum_iplv": null,
481
+ "minimum_integrated_energy_efficiency_ratio": null,
482
+ "cool_cap_ft": "HPACCoolCapFT",
483
+ "cool_cap_fflow": "HPACCoolCapFFF",
484
+ "cool_eir_ft": "HPACCOOLEIRFT",
485
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
486
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
487
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
488
+ },
489
+ {
490
+ "template": "DOE Ref Pre-1980",
491
+ "cooling_type": "AirCooled",
492
+ "heating_type": "All Other",
493
+ "subcategory": "Split System",
494
+ "minimum_capacity": 135000.0,
495
+ "maximum_capacity": 239999.0,
496
+ "minimum_seasonal_efficiency": null,
497
+ "minimum_full_load_efficiency": 9.1,
498
+ "minimum_iplv": null,
499
+ "minimum_integrated_energy_efficiency_ratio": null,
500
+ "cool_cap_ft": "HPACCoolCapFT",
501
+ "cool_cap_fflow": "HPACCoolCapFFF",
502
+ "cool_eir_ft": "HPACCOOLEIRFT",
503
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
504
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
505
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
506
+ },
507
+ {
508
+ "template": "DOE Ref Pre-1980",
509
+ "cooling_type": "AirCooled",
510
+ "heating_type": "All Other",
511
+ "subcategory": "Single Package",
512
+ "minimum_capacity": 135000.0,
513
+ "maximum_capacity": 239999.0,
514
+ "minimum_seasonal_efficiency": null,
515
+ "minimum_full_load_efficiency": 9.1,
516
+ "minimum_iplv": null,
517
+ "minimum_integrated_energy_efficiency_ratio": null,
518
+ "cool_cap_ft": "HPACCoolCapFT",
519
+ "cool_cap_fflow": "HPACCoolCapFFF",
520
+ "cool_eir_ft": "HPACCOOLEIRFT",
521
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
522
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
523
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
524
+ },
525
+ {
526
+ "template": "DOE Ref Pre-1980",
527
+ "cooling_type": "AirCooled",
528
+ "heating_type": "Electric Resistance or None",
529
+ "subcategory": "Split System",
530
+ "minimum_capacity": 240000.0,
531
+ "maximum_capacity": 9999999.0,
532
+ "minimum_seasonal_efficiency": null,
533
+ "minimum_full_load_efficiency": 9.0,
534
+ "minimum_iplv": 9.2,
535
+ "minimum_integrated_energy_efficiency_ratio": null,
536
+ "cool_cap_ft": "HPACCoolCapFT",
537
+ "cool_cap_fflow": "HPACCoolCapFFF",
538
+ "cool_eir_ft": "HPACCOOLEIRFT",
539
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
540
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
541
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
542
+ },
543
+ {
544
+ "template": "DOE Ref Pre-1980",
545
+ "cooling_type": "AirCooled",
546
+ "heating_type": "Electric Resistance or None",
547
+ "subcategory": "Single Package",
548
+ "minimum_capacity": 240000.0,
549
+ "maximum_capacity": 9999999.0,
550
+ "minimum_seasonal_efficiency": null,
551
+ "minimum_full_load_efficiency": 9.0,
552
+ "minimum_iplv": 9.2,
553
+ "minimum_integrated_energy_efficiency_ratio": null,
554
+ "cool_cap_ft": "HPACCoolCapFT",
555
+ "cool_cap_fflow": "HPACCoolCapFFF",
556
+ "cool_eir_ft": "HPACCOOLEIRFT",
557
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
558
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
559
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
560
+ },
561
+ {
562
+ "template": "DOE Ref Pre-1980",
563
+ "cooling_type": "AirCooled",
564
+ "heating_type": "All Other",
565
+ "subcategory": "Split System",
566
+ "minimum_capacity": 240000.0,
567
+ "maximum_capacity": 9999999.0,
568
+ "minimum_seasonal_efficiency": null,
569
+ "minimum_full_load_efficiency": 8.8,
570
+ "minimum_iplv": 9.0,
571
+ "minimum_integrated_energy_efficiency_ratio": null,
572
+ "cool_cap_ft": "HPACCoolCapFT",
573
+ "cool_cap_fflow": "HPACCoolCapFFF",
574
+ "cool_eir_ft": "HPACCOOLEIRFT",
575
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
576
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
577
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
578
+ },
579
+ {
580
+ "template": "DOE Ref Pre-1980",
581
+ "cooling_type": "AirCooled",
582
+ "heating_type": "All Other",
583
+ "subcategory": "Single Package",
584
+ "minimum_capacity": 240000.0,
585
+ "maximum_capacity": 9999999.0,
586
+ "minimum_seasonal_efficiency": null,
587
+ "minimum_full_load_efficiency": 8.8,
588
+ "minimum_iplv": 9.0,
589
+ "minimum_integrated_energy_efficiency_ratio": null,
590
+ "cool_cap_ft": "HPACCoolCapFT",
591
+ "cool_cap_fflow": "HPACCoolCapFFF",
592
+ "cool_eir_ft": "HPACCOOLEIRFT",
593
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
594
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
595
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
596
+ },
597
+ {
598
+ "template": "DOE Ref 1980-2004",
599
+ "cooling_type": "AirCooled",
600
+ "heating_type": null,
601
+ "subcategory": "Split System",
602
+ "minimum_capacity": 0.0,
603
+ "maximum_capacity": 64999.0,
604
+ "minimum_seasonal_efficiency": 10.0,
605
+ "minimum_full_load_efficiency": null,
606
+ "minimum_iplv": null,
607
+ "minimum_integrated_energy_efficiency_ratio": null,
608
+ "cool_cap_ft": "HPACCoolCapFT",
609
+ "cool_cap_fflow": "HPACCoolCapFFF",
610
+ "cool_eir_ft": "HPACCOOLEIRFT",
611
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
612
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
613
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
614
+ },
615
+ {
616
+ "template": "DOE Ref 1980-2004",
617
+ "cooling_type": "AirCooled",
618
+ "heating_type": null,
619
+ "subcategory": "Single Package",
620
+ "minimum_capacity": 0.0,
621
+ "maximum_capacity": 64999.0,
622
+ "minimum_seasonal_efficiency": 9.7,
623
+ "minimum_full_load_efficiency": null,
624
+ "minimum_iplv": null,
625
+ "minimum_integrated_energy_efficiency_ratio": null,
626
+ "cool_cap_ft": "HPACCoolCapFT",
627
+ "cool_cap_fflow": "HPACCoolCapFFF",
628
+ "cool_eir_ft": "HPACCOOLEIRFT",
629
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
630
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
631
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
632
+ },
633
+ {
634
+ "template": "DOE Ref 1980-2004",
635
+ "cooling_type": "ThroughWall",
636
+ "heating_type": null,
637
+ "subcategory": "Split System",
638
+ "minimum_capacity": 0.0,
639
+ "maximum_capacity": 29999.0,
640
+ "minimum_seasonal_efficiency": 10.0,
641
+ "minimum_full_load_efficiency": null,
642
+ "minimum_iplv": null,
643
+ "minimum_integrated_energy_efficiency_ratio": null,
644
+ "cool_cap_ft": "HPACCoolCapFT",
645
+ "cool_cap_fflow": "HPACCoolCapFFF",
646
+ "cool_eir_ft": "HPACCOOLEIRFT",
647
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
648
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
649
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
650
+ },
651
+ {
652
+ "template": "DOE Ref 1980-2004",
653
+ "cooling_type": "ThroughWall",
654
+ "heating_type": null,
655
+ "subcategory": "Single Package",
656
+ "minimum_capacity": 0.0,
657
+ "maximum_capacity": 29999.0,
658
+ "minimum_seasonal_efficiency": 9.7,
659
+ "minimum_full_load_efficiency": null,
660
+ "minimum_iplv": null,
661
+ "minimum_integrated_energy_efficiency_ratio": null,
662
+ "cool_cap_ft": "HPACCoolCapFT",
663
+ "cool_cap_fflow": "HPACCoolCapFFF",
664
+ "cool_eir_ft": "HPACCOOLEIRFT",
665
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
666
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
667
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
668
+ },
669
+ {
670
+ "template": "DOE Ref 1980-2004",
671
+ "cooling_type": "SmallDuctHighVelocity",
672
+ "heating_type": null,
673
+ "subcategory": "Split System",
674
+ "minimum_capacity": 0.0,
675
+ "maximum_capacity": 64999.0,
676
+ "minimum_seasonal_efficiency": 10.0,
677
+ "minimum_full_load_efficiency": null,
678
+ "minimum_iplv": null,
679
+ "minimum_integrated_energy_efficiency_ratio": null,
680
+ "cool_cap_ft": "HPACCoolCapFT",
681
+ "cool_cap_fflow": "HPACCoolCapFFF",
682
+ "cool_eir_ft": "HPACCOOLEIRFT",
683
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
684
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
685
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
686
+ },
687
+ {
688
+ "template": "DOE Ref 1980-2004",
689
+ "cooling_type": "AirCooled",
690
+ "heating_type": "Electric Resistance or None",
691
+ "subcategory": "Split System",
692
+ "minimum_capacity": 65000.0,
693
+ "maximum_capacity": 134999.0,
694
+ "minimum_seasonal_efficiency": null,
695
+ "minimum_full_load_efficiency": 10.1,
696
+ "minimum_iplv": null,
697
+ "minimum_integrated_energy_efficiency_ratio": null,
698
+ "cool_cap_ft": "HPACCoolCapFT",
699
+ "cool_cap_fflow": "HPACCoolCapFFF",
700
+ "cool_eir_ft": "HPACCOOLEIRFT",
701
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
702
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
703
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
704
+ },
705
+ {
706
+ "template": "DOE Ref 1980-2004",
707
+ "cooling_type": "AirCooled",
708
+ "heating_type": "Electric Resistance or None",
709
+ "subcategory": "Single Package",
710
+ "minimum_capacity": 65000.0,
711
+ "maximum_capacity": 134999.0,
712
+ "minimum_seasonal_efficiency": null,
713
+ "minimum_full_load_efficiency": 10.1,
714
+ "minimum_iplv": null,
715
+ "minimum_integrated_energy_efficiency_ratio": null,
716
+ "cool_cap_ft": "HPACCoolCapFT",
717
+ "cool_cap_fflow": "HPACCoolCapFFF",
718
+ "cool_eir_ft": "HPACCOOLEIRFT",
719
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
720
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
721
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
722
+ },
723
+ {
724
+ "template": "DOE Ref 1980-2004",
725
+ "cooling_type": "AirCooled",
726
+ "heating_type": "All Other",
727
+ "subcategory": "Split System",
728
+ "minimum_capacity": 65000.0,
729
+ "maximum_capacity": 134999.0,
730
+ "minimum_seasonal_efficiency": null,
731
+ "minimum_full_load_efficiency": 9.9,
732
+ "minimum_iplv": null,
733
+ "minimum_integrated_energy_efficiency_ratio": null,
734
+ "cool_cap_ft": "HPACCoolCapFT",
735
+ "cool_cap_fflow": "HPACCoolCapFFF",
736
+ "cool_eir_ft": "HPACCOOLEIRFT",
737
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
738
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
739
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
740
+ },
741
+ {
742
+ "template": "DOE Ref 1980-2004",
743
+ "cooling_type": "AirCooled",
744
+ "heating_type": "All Other",
745
+ "subcategory": "Single Package",
746
+ "minimum_capacity": 65000.0,
747
+ "maximum_capacity": 134999.0,
748
+ "minimum_seasonal_efficiency": null,
749
+ "minimum_full_load_efficiency": 9.9,
750
+ "minimum_iplv": null,
751
+ "minimum_integrated_energy_efficiency_ratio": null,
752
+ "cool_cap_ft": "HPACCoolCapFT",
753
+ "cool_cap_fflow": "HPACCoolCapFFF",
754
+ "cool_eir_ft": "HPACCOOLEIRFT",
755
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
756
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
757
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
758
+ },
759
+ {
760
+ "template": "DOE Ref 1980-2004",
761
+ "cooling_type": "AirCooled",
762
+ "heating_type": "Electric Resistance or None",
763
+ "subcategory": "Split System",
764
+ "minimum_capacity": 135000.0,
765
+ "maximum_capacity": 239999.0,
766
+ "minimum_seasonal_efficiency": null,
767
+ "minimum_full_load_efficiency": 9.3,
768
+ "minimum_iplv": null,
769
+ "minimum_integrated_energy_efficiency_ratio": null,
770
+ "cool_cap_ft": "HPACCoolCapFT",
771
+ "cool_cap_fflow": "HPACCoolCapFFF",
772
+ "cool_eir_ft": "HPACCOOLEIRFT",
773
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
774
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
775
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
776
+ },
777
+ {
778
+ "template": "DOE Ref 1980-2004",
779
+ "cooling_type": "AirCooled",
780
+ "heating_type": "Electric Resistance or None",
781
+ "subcategory": "Single Package",
782
+ "minimum_capacity": 135000.0,
783
+ "maximum_capacity": 239999.0,
784
+ "minimum_seasonal_efficiency": null,
785
+ "minimum_full_load_efficiency": 9.3,
786
+ "minimum_iplv": null,
787
+ "minimum_integrated_energy_efficiency_ratio": null,
788
+ "cool_cap_ft": "HPACCoolCapFT",
789
+ "cool_cap_fflow": "HPACCoolCapFFF",
790
+ "cool_eir_ft": "HPACCOOLEIRFT",
791
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
792
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
793
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
794
+ },
795
+ {
796
+ "template": "DOE Ref 1980-2004",
797
+ "cooling_type": "AirCooled",
798
+ "heating_type": "All Other",
799
+ "subcategory": "Split System",
800
+ "minimum_capacity": 135000.0,
801
+ "maximum_capacity": 239999.0,
802
+ "minimum_seasonal_efficiency": null,
803
+ "minimum_full_load_efficiency": 9.1,
804
+ "minimum_iplv": null,
805
+ "minimum_integrated_energy_efficiency_ratio": null,
806
+ "cool_cap_ft": "HPACCoolCapFT",
807
+ "cool_cap_fflow": "HPACCoolCapFFF",
808
+ "cool_eir_ft": "HPACCOOLEIRFT",
809
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
810
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
811
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
812
+ },
813
+ {
814
+ "template": "DOE Ref 1980-2004",
815
+ "cooling_type": "AirCooled",
816
+ "heating_type": "All Other",
817
+ "subcategory": "Single Package",
818
+ "minimum_capacity": 135000.0,
819
+ "maximum_capacity": 239999.0,
820
+ "minimum_seasonal_efficiency": null,
821
+ "minimum_full_load_efficiency": 9.1,
822
+ "minimum_iplv": null,
823
+ "minimum_integrated_energy_efficiency_ratio": null,
824
+ "cool_cap_ft": "HPACCoolCapFT",
825
+ "cool_cap_fflow": "HPACCoolCapFFF",
826
+ "cool_eir_ft": "HPACCOOLEIRFT",
827
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
828
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
829
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
830
+ },
831
+ {
832
+ "template": "DOE Ref 1980-2004",
833
+ "cooling_type": "AirCooled",
834
+ "heating_type": "Electric Resistance or None",
835
+ "subcategory": "Split System",
836
+ "minimum_capacity": 240000.0,
837
+ "maximum_capacity": 9999999.0,
838
+ "minimum_seasonal_efficiency": null,
839
+ "minimum_full_load_efficiency": 9.0,
840
+ "minimum_iplv": 9.2,
841
+ "minimum_integrated_energy_efficiency_ratio": null,
842
+ "cool_cap_ft": "HPACCoolCapFT",
843
+ "cool_cap_fflow": "HPACCoolCapFFF",
844
+ "cool_eir_ft": "HPACCOOLEIRFT",
845
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
846
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
847
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
848
+ },
849
+ {
850
+ "template": "DOE Ref 1980-2004",
851
+ "cooling_type": "AirCooled",
852
+ "heating_type": "Electric Resistance or None",
853
+ "subcategory": "Single Package",
854
+ "minimum_capacity": 240000.0,
855
+ "maximum_capacity": 9999999.0,
856
+ "minimum_seasonal_efficiency": null,
857
+ "minimum_full_load_efficiency": 9.0,
858
+ "minimum_iplv": 9.2,
859
+ "minimum_integrated_energy_efficiency_ratio": null,
860
+ "cool_cap_ft": "HPACCoolCapFT",
861
+ "cool_cap_fflow": "HPACCoolCapFFF",
862
+ "cool_eir_ft": "HPACCOOLEIRFT",
863
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
864
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
865
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
866
+ },
867
+ {
868
+ "template": "DOE Ref 1980-2004",
869
+ "cooling_type": "AirCooled",
870
+ "heating_type": "All Other",
871
+ "subcategory": "Split System",
872
+ "minimum_capacity": 240000.0,
873
+ "maximum_capacity": 9999999.0,
874
+ "minimum_seasonal_efficiency": null,
875
+ "minimum_full_load_efficiency": 8.8,
876
+ "minimum_iplv": 9.0,
877
+ "minimum_integrated_energy_efficiency_ratio": null,
878
+ "cool_cap_ft": "HPACCoolCapFT",
879
+ "cool_cap_fflow": "HPACCoolCapFFF",
880
+ "cool_eir_ft": "HPACCOOLEIRFT",
881
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
882
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
883
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
884
+ },
885
+ {
886
+ "template": "DOE Ref 1980-2004",
887
+ "cooling_type": "AirCooled",
888
+ "heating_type": "All Other",
889
+ "subcategory": "Single Package",
890
+ "minimum_capacity": 240000.0,
891
+ "maximum_capacity": 9999999.0,
892
+ "minimum_seasonal_efficiency": null,
893
+ "minimum_full_load_efficiency": 8.8,
894
+ "minimum_iplv": 9.0,
895
+ "minimum_integrated_energy_efficiency_ratio": null,
896
+ "cool_cap_ft": "HPACCoolCapFT",
897
+ "cool_cap_fflow": "HPACCoolCapFFF",
898
+ "cool_eir_ft": "HPACCOOLEIRFT",
899
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
900
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
901
+ "notes": "From 90.1-2004 since DOE Reference Buildings did not have any heat pumps"
902
+ },
903
+ {
904
+ "template": "90.1-2004",
905
+ "cooling_type": "AirCooled",
906
+ "heating_type": null,
907
+ "subcategory": "Split System",
908
+ "minimum_capacity": 0.0,
909
+ "maximum_capacity": 64999.0,
910
+ "minimum_seasonal_efficiency": 10.0,
911
+ "minimum_full_load_efficiency": null,
912
+ "minimum_iplv": null,
913
+ "minimum_integrated_energy_efficiency_ratio": null,
914
+ "cool_cap_ft": "HPACCoolCapFT",
915
+ "cool_cap_fflow": "HPACCoolCapFFF",
916
+ "cool_eir_ft": "HPACCOOLEIRFT",
917
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
918
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
919
+ "notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
920
+ },
921
+ {
922
+ "template": "90.1-2004",
923
+ "cooling_type": "AirCooled",
924
+ "heating_type": null,
925
+ "subcategory": "Single Package",
926
+ "minimum_capacity": 0.0,
927
+ "maximum_capacity": 64999.0,
928
+ "minimum_seasonal_efficiency": 9.7,
929
+ "minimum_full_load_efficiency": null,
930
+ "minimum_iplv": null,
931
+ "minimum_integrated_energy_efficiency_ratio": null,
932
+ "cool_cap_ft": "HPACCoolCapFT",
933
+ "cool_cap_fflow": "HPACCoolCapFFF",
934
+ "cool_eir_ft": "HPACCOOLEIRFT",
935
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
936
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
937
+ "notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
938
+ },
939
+ {
940
+ "template": "90.1-2004",
941
+ "cooling_type": "ThroughWall",
942
+ "heating_type": null,
943
+ "subcategory": "Split System",
944
+ "minimum_capacity": 0.0,
945
+ "maximum_capacity": 29999.0,
946
+ "minimum_seasonal_efficiency": 10.0,
947
+ "minimum_full_load_efficiency": null,
948
+ "minimum_iplv": null,
949
+ "minimum_integrated_energy_efficiency_ratio": null,
950
+ "cool_cap_ft": "HPACCoolCapFT",
951
+ "cool_cap_fflow": "HPACCoolCapFFF",
952
+ "cool_eir_ft": "HPACCOOLEIRFT",
953
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
954
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
955
+ "notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
956
+ },
957
+ {
958
+ "template": "90.1-2004",
959
+ "cooling_type": "ThroughWall",
960
+ "heating_type": null,
961
+ "subcategory": "Single Package",
962
+ "minimum_capacity": 0.0,
963
+ "maximum_capacity": 29999.0,
964
+ "minimum_seasonal_efficiency": 9.7,
965
+ "minimum_full_load_efficiency": null,
966
+ "minimum_iplv": null,
967
+ "minimum_integrated_energy_efficiency_ratio": null,
968
+ "cool_cap_ft": "HPACCoolCapFT",
969
+ "cool_cap_fflow": "HPACCoolCapFFF",
970
+ "cool_eir_ft": "HPACCOOLEIRFT",
971
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
972
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
973
+ "notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
974
+ },
975
+ {
976
+ "template": "90.1-2004",
977
+ "cooling_type": "SmallDuctHighVelocity",
978
+ "heating_type": null,
979
+ "subcategory": "Split System",
980
+ "minimum_capacity": 0.0,
981
+ "maximum_capacity": 64999.0,
982
+ "minimum_seasonal_efficiency": 10.0,
983
+ "minimum_full_load_efficiency": null,
984
+ "minimum_iplv": null,
985
+ "minimum_integrated_energy_efficiency_ratio": null,
986
+ "cool_cap_ft": "HPACCoolCapFT",
987
+ "cool_cap_fflow": "HPACCoolCapFFF",
988
+ "cool_eir_ft": "HPACCOOLEIRFT",
989
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
990
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
991
+ "notes": "From 90.1-2004 Table 6.8.1B"
992
+ },
993
+ {
994
+ "template": "90.1-2004",
995
+ "cooling_type": "AirCooled",
996
+ "heating_type": "Electric Resistance or None",
997
+ "subcategory": "Split System",
998
+ "minimum_capacity": 65000.0,
999
+ "maximum_capacity": 134999.0,
1000
+ "minimum_seasonal_efficiency": null,
1001
+ "minimum_full_load_efficiency": 10.1,
1002
+ "minimum_iplv": null,
1003
+ "minimum_integrated_energy_efficiency_ratio": null,
1004
+ "cool_cap_ft": "HPACCoolCapFT",
1005
+ "cool_cap_fflow": "HPACCoolCapFFF",
1006
+ "cool_eir_ft": "HPACCOOLEIRFT",
1007
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1008
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1009
+ "notes": "From 90.1-2004 Table 6.8.1B"
1010
+ },
1011
+ {
1012
+ "template": "90.1-2004",
1013
+ "cooling_type": "AirCooled",
1014
+ "heating_type": "Electric Resistance or None",
1015
+ "subcategory": "Single Package",
1016
+ "minimum_capacity": 65000.0,
1017
+ "maximum_capacity": 134999.0,
1018
+ "minimum_seasonal_efficiency": null,
1019
+ "minimum_full_load_efficiency": 10.1,
1020
+ "minimum_iplv": null,
1021
+ "minimum_integrated_energy_efficiency_ratio": null,
1022
+ "cool_cap_ft": "HPACCoolCapFT",
1023
+ "cool_cap_fflow": "HPACCoolCapFFF",
1024
+ "cool_eir_ft": "HPACCOOLEIRFT",
1025
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1026
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1027
+ "notes": "From 90.1-2004 Table 6.8.1B"
1028
+ },
1029
+ {
1030
+ "template": "90.1-2004",
1031
+ "cooling_type": "AirCooled",
1032
+ "heating_type": "All Other",
1033
+ "subcategory": "Split System",
1034
+ "minimum_capacity": 65000.0,
1035
+ "maximum_capacity": 134999.0,
1036
+ "minimum_seasonal_efficiency": null,
1037
+ "minimum_full_load_efficiency": 9.9,
1038
+ "minimum_iplv": null,
1039
+ "minimum_integrated_energy_efficiency_ratio": null,
1040
+ "cool_cap_ft": "HPACCoolCapFT",
1041
+ "cool_cap_fflow": "HPACCoolCapFFF",
1042
+ "cool_eir_ft": "HPACCOOLEIRFT",
1043
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1044
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1045
+ "notes": "From 90.1-2004 Table 6.8.1B"
1046
+ },
1047
+ {
1048
+ "template": "90.1-2004",
1049
+ "cooling_type": "AirCooled",
1050
+ "heating_type": "All Other",
1051
+ "subcategory": "Single Package",
1052
+ "minimum_capacity": 65000.0,
1053
+ "maximum_capacity": 134999.0,
1054
+ "minimum_seasonal_efficiency": null,
1055
+ "minimum_full_load_efficiency": 9.9,
1056
+ "minimum_iplv": null,
1057
+ "minimum_integrated_energy_efficiency_ratio": null,
1058
+ "cool_cap_ft": "HPACCoolCapFT",
1059
+ "cool_cap_fflow": "HPACCoolCapFFF",
1060
+ "cool_eir_ft": "HPACCOOLEIRFT",
1061
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1062
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1063
+ "notes": "From 90.1-2004 Table 6.8.1B"
1064
+ },
1065
+ {
1066
+ "template": "90.1-2004",
1067
+ "cooling_type": "AirCooled",
1068
+ "heating_type": "Electric Resistance or None",
1069
+ "subcategory": "Split System",
1070
+ "minimum_capacity": 135000.0,
1071
+ "maximum_capacity": 239999.0,
1072
+ "minimum_seasonal_efficiency": null,
1073
+ "minimum_full_load_efficiency": 9.3,
1074
+ "minimum_iplv": null,
1075
+ "minimum_integrated_energy_efficiency_ratio": null,
1076
+ "cool_cap_ft": "HPACCoolCapFT",
1077
+ "cool_cap_fflow": "HPACCoolCapFFF",
1078
+ "cool_eir_ft": "HPACCOOLEIRFT",
1079
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1080
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1081
+ "notes": "From 90.1-2004 Table 6.8.1B"
1082
+ },
1083
+ {
1084
+ "template": "90.1-2004",
1085
+ "cooling_type": "AirCooled",
1086
+ "heating_type": "Electric Resistance or None",
1087
+ "subcategory": "Single Package",
1088
+ "minimum_capacity": 135000.0,
1089
+ "maximum_capacity": 239999.0,
1090
+ "minimum_seasonal_efficiency": null,
1091
+ "minimum_full_load_efficiency": 9.3,
1092
+ "minimum_iplv": null,
1093
+ "minimum_integrated_energy_efficiency_ratio": null,
1094
+ "cool_cap_ft": "HPACCoolCapFT",
1095
+ "cool_cap_fflow": "HPACCoolCapFFF",
1096
+ "cool_eir_ft": "HPACCOOLEIRFT",
1097
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1098
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1099
+ "notes": "From 90.1-2004 Table 6.8.1B"
1100
+ },
1101
+ {
1102
+ "template": "90.1-2004",
1103
+ "cooling_type": "AirCooled",
1104
+ "heating_type": "All Other",
1105
+ "subcategory": "Split System",
1106
+ "minimum_capacity": 135000.0,
1107
+ "maximum_capacity": 239999.0,
1108
+ "minimum_seasonal_efficiency": null,
1109
+ "minimum_full_load_efficiency": 9.1,
1110
+ "minimum_iplv": null,
1111
+ "minimum_integrated_energy_efficiency_ratio": null,
1112
+ "cool_cap_ft": "HPACCoolCapFT",
1113
+ "cool_cap_fflow": "HPACCoolCapFFF",
1114
+ "cool_eir_ft": "HPACCOOLEIRFT",
1115
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1116
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1117
+ "notes": "From 90.1-2004 Table 6.8.1B"
1118
+ },
1119
+ {
1120
+ "template": "90.1-2004",
1121
+ "cooling_type": "AirCooled",
1122
+ "heating_type": "All Other",
1123
+ "subcategory": "Single Package",
1124
+ "minimum_capacity": 135000.0,
1125
+ "maximum_capacity": 239999.0,
1126
+ "minimum_seasonal_efficiency": null,
1127
+ "minimum_full_load_efficiency": 9.1,
1128
+ "minimum_iplv": null,
1129
+ "minimum_integrated_energy_efficiency_ratio": null,
1130
+ "cool_cap_ft": "HPACCoolCapFT",
1131
+ "cool_cap_fflow": "HPACCoolCapFFF",
1132
+ "cool_eir_ft": "HPACCOOLEIRFT",
1133
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1134
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1135
+ "notes": "From 90.1-2004 Table 6.8.1B"
1136
+ },
1137
+ {
1138
+ "template": "90.1-2004",
1139
+ "cooling_type": "AirCooled",
1140
+ "heating_type": "Electric Resistance or None",
1141
+ "subcategory": "Split System",
1142
+ "minimum_capacity": 240000.0,
1143
+ "maximum_capacity": 9999999.0,
1144
+ "minimum_seasonal_efficiency": null,
1145
+ "minimum_full_load_efficiency": 9.0,
1146
+ "minimum_iplv": 9.2,
1147
+ "minimum_integrated_energy_efficiency_ratio": null,
1148
+ "cool_cap_ft": "HPACCoolCapFT",
1149
+ "cool_cap_fflow": "HPACCoolCapFFF",
1150
+ "cool_eir_ft": "HPACCOOLEIRFT",
1151
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1152
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1153
+ "notes": "From 90.1-2004 Table 6.8.1B"
1154
+ },
1155
+ {
1156
+ "template": "90.1-2004",
1157
+ "cooling_type": "AirCooled",
1158
+ "heating_type": "Electric Resistance or None",
1159
+ "subcategory": "Single Package",
1160
+ "minimum_capacity": 240000.0,
1161
+ "maximum_capacity": 9999999.0,
1162
+ "minimum_seasonal_efficiency": null,
1163
+ "minimum_full_load_efficiency": 9.0,
1164
+ "minimum_iplv": 9.2,
1165
+ "minimum_integrated_energy_efficiency_ratio": null,
1166
+ "cool_cap_ft": "HPACCoolCapFT",
1167
+ "cool_cap_fflow": "HPACCoolCapFFF",
1168
+ "cool_eir_ft": "HPACCOOLEIRFT",
1169
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1170
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1171
+ "notes": "From 90.1-2004 Table 6.8.1B"
1172
+ },
1173
+ {
1174
+ "template": "90.1-2004",
1175
+ "cooling_type": "AirCooled",
1176
+ "heating_type": "All Other",
1177
+ "subcategory": "Split System",
1178
+ "minimum_capacity": 240000.0,
1179
+ "maximum_capacity": 9999999.0,
1180
+ "minimum_seasonal_efficiency": null,
1181
+ "minimum_full_load_efficiency": 8.8,
1182
+ "minimum_iplv": 9.0,
1183
+ "minimum_integrated_energy_efficiency_ratio": null,
1184
+ "cool_cap_ft": "HPACCoolCapFT",
1185
+ "cool_cap_fflow": "HPACCoolCapFFF",
1186
+ "cool_eir_ft": "HPACCOOLEIRFT",
1187
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1188
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1189
+ "notes": "From 90.1-2004 Table 6.8.1B"
1190
+ },
1191
+ {
1192
+ "template": "90.1-2004",
1193
+ "cooling_type": "AirCooled",
1194
+ "heating_type": "All Other",
1195
+ "subcategory": "Single Package",
1196
+ "minimum_capacity": 240000.0,
1197
+ "maximum_capacity": 9999999.0,
1198
+ "minimum_seasonal_efficiency": null,
1199
+ "minimum_full_load_efficiency": 8.8,
1200
+ "minimum_iplv": 9.0,
1201
+ "minimum_integrated_energy_efficiency_ratio": null,
1202
+ "cool_cap_ft": "HPACCoolCapFT",
1203
+ "cool_cap_fflow": "HPACCoolCapFFF",
1204
+ "cool_eir_ft": "HPACCOOLEIRFT",
1205
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1206
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1207
+ "notes": "From 90.1-2004 Table 6.8.1B"
1208
+ },
1209
+ {
1210
+ "template": "90.1-2007",
1211
+ "cooling_type": "AirCooled",
1212
+ "heating_type": null,
1213
+ "subcategory": "Split System",
1214
+ "minimum_capacity": 0.0,
1215
+ "maximum_capacity": 64999.0,
1216
+ "minimum_seasonal_efficiency": 13.0,
1217
+ "minimum_full_load_efficiency": null,
1218
+ "minimum_iplv": null,
1219
+ "minimum_integrated_energy_efficiency_ratio": null,
1220
+ "cool_cap_ft": "HPACCoolCapFT",
1221
+ "cool_cap_fflow": "HPACCoolCapFFF",
1222
+ "cool_eir_ft": "HPACCOOLEIRFT",
1223
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1224
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1225
+ "notes": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006"
1226
+ },
1227
+ {
1228
+ "template": "90.1-2007",
1229
+ "cooling_type": "AirCooled",
1230
+ "heating_type": null,
1231
+ "subcategory": "Single Package",
1232
+ "minimum_capacity": 0.0,
1233
+ "maximum_capacity": 64999.0,
1234
+ "minimum_seasonal_efficiency": 13.0,
1235
+ "minimum_full_load_efficiency": null,
1236
+ "minimum_iplv": null,
1237
+ "minimum_integrated_energy_efficiency_ratio": null,
1238
+ "cool_cap_ft": "HPACCoolCapFT",
1239
+ "cool_cap_fflow": "HPACCoolCapFFF",
1240
+ "cool_eir_ft": "HPACCOOLEIRFT",
1241
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1242
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1243
+ "notes": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006"
1244
+ },
1245
+ {
1246
+ "template": "90.1-2007",
1247
+ "cooling_type": "ThroughWall",
1248
+ "heating_type": null,
1249
+ "subcategory": "Split System",
1250
+ "minimum_capacity": 0.0,
1251
+ "maximum_capacity": 29999.0,
1252
+ "minimum_seasonal_efficiency": 10.9,
1253
+ "minimum_full_load_efficiency": null,
1254
+ "minimum_iplv": null,
1255
+ "minimum_integrated_energy_efficiency_ratio": null,
1256
+ "cool_cap_ft": "HPACCoolCapFT",
1257
+ "cool_cap_fflow": "HPACCoolCapFFF",
1258
+ "cool_eir_ft": "HPACCOOLEIRFT",
1259
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1260
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1261
+ "notes": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006"
1262
+ },
1263
+ {
1264
+ "template": "90.1-2007",
1265
+ "cooling_type": "ThroughWall",
1266
+ "heating_type": null,
1267
+ "subcategory": "Single Package",
1268
+ "minimum_capacity": 0.0,
1269
+ "maximum_capacity": 29999.0,
1270
+ "minimum_seasonal_efficiency": 10.6,
1271
+ "minimum_full_load_efficiency": null,
1272
+ "minimum_iplv": null,
1273
+ "minimum_integrated_energy_efficiency_ratio": null,
1274
+ "cool_cap_ft": "HPACCoolCapFT",
1275
+ "cool_cap_fflow": "HPACCoolCapFFF",
1276
+ "cool_eir_ft": "HPACCOOLEIRFT",
1277
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1278
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1279
+ "notes": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006"
1280
+ },
1281
+ {
1282
+ "template": "90.1-2007",
1283
+ "cooling_type": "AirCooled",
1284
+ "heating_type": "Electric Resistance or None",
1285
+ "subcategory": "Split System",
1286
+ "minimum_capacity": 65000.0,
1287
+ "maximum_capacity": 134999.0,
1288
+ "minimum_seasonal_efficiency": null,
1289
+ "minimum_full_load_efficiency": 10.1,
1290
+ "minimum_iplv": null,
1291
+ "minimum_integrated_energy_efficiency_ratio": null,
1292
+ "cool_cap_ft": "HPACCoolCapFT",
1293
+ "cool_cap_fflow": "HPACCoolCapFFF",
1294
+ "cool_eir_ft": "HPACCOOLEIRFT",
1295
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1296
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1297
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1298
+ },
1299
+ {
1300
+ "template": "90.1-2007",
1301
+ "cooling_type": "AirCooled",
1302
+ "heating_type": "Electric Resistance or None",
1303
+ "subcategory": "Single Package",
1304
+ "minimum_capacity": 65000.0,
1305
+ "maximum_capacity": 134999.0,
1306
+ "minimum_seasonal_efficiency": null,
1307
+ "minimum_full_load_efficiency": 10.1,
1308
+ "minimum_iplv": null,
1309
+ "minimum_integrated_energy_efficiency_ratio": null,
1310
+ "cool_cap_ft": "HPACCoolCapFT",
1311
+ "cool_cap_fflow": "HPACCoolCapFFF",
1312
+ "cool_eir_ft": "HPACCOOLEIRFT",
1313
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1314
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1315
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1316
+ },
1317
+ {
1318
+ "template": "90.1-2007",
1319
+ "cooling_type": "AirCooled",
1320
+ "heating_type": "All Other",
1321
+ "subcategory": "Split System",
1322
+ "minimum_capacity": 65000.0,
1323
+ "maximum_capacity": 134999.0,
1324
+ "minimum_seasonal_efficiency": null,
1325
+ "minimum_full_load_efficiency": 9.9,
1326
+ "minimum_iplv": null,
1327
+ "minimum_integrated_energy_efficiency_ratio": null,
1328
+ "cool_cap_ft": "HPACCoolCapFT",
1329
+ "cool_cap_fflow": "HPACCoolCapFFF",
1330
+ "cool_eir_ft": "HPACCOOLEIRFT",
1331
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1332
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1333
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1334
+ },
1335
+ {
1336
+ "template": "90.1-2007",
1337
+ "cooling_type": "AirCooled",
1338
+ "heating_type": "All Other",
1339
+ "subcategory": "Single Package",
1340
+ "minimum_capacity": 65000.0,
1341
+ "maximum_capacity": 134999.0,
1342
+ "minimum_seasonal_efficiency": null,
1343
+ "minimum_full_load_efficiency": 9.9,
1344
+ "minimum_iplv": null,
1345
+ "minimum_integrated_energy_efficiency_ratio": null,
1346
+ "cool_cap_ft": "HPACCoolCapFT",
1347
+ "cool_cap_fflow": "HPACCoolCapFFF",
1348
+ "cool_eir_ft": "HPACCOOLEIRFT",
1349
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1350
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1351
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1352
+ },
1353
+ {
1354
+ "template": "90.1-2007",
1355
+ "cooling_type": "AirCooled",
1356
+ "heating_type": "Electric Resistance or None",
1357
+ "subcategory": "Split System",
1358
+ "minimum_capacity": 135000.0,
1359
+ "maximum_capacity": 239999.0,
1360
+ "minimum_seasonal_efficiency": null,
1361
+ "minimum_full_load_efficiency": 9.3,
1362
+ "minimum_iplv": null,
1363
+ "minimum_integrated_energy_efficiency_ratio": null,
1364
+ "cool_cap_ft": "HPACCoolCapFT",
1365
+ "cool_cap_fflow": "HPACCoolCapFFF",
1366
+ "cool_eir_ft": "HPACCOOLEIRFT",
1367
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1368
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1369
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1370
+ },
1371
+ {
1372
+ "template": "90.1-2007",
1373
+ "cooling_type": "AirCooled",
1374
+ "heating_type": "Electric Resistance or None",
1375
+ "subcategory": "Single Package",
1376
+ "minimum_capacity": 135000.0,
1377
+ "maximum_capacity": 239999.0,
1378
+ "minimum_seasonal_efficiency": null,
1379
+ "minimum_full_load_efficiency": 9.3,
1380
+ "minimum_iplv": null,
1381
+ "minimum_integrated_energy_efficiency_ratio": null,
1382
+ "cool_cap_ft": "HPACCoolCapFT",
1383
+ "cool_cap_fflow": "HPACCoolCapFFF",
1384
+ "cool_eir_ft": "HPACCOOLEIRFT",
1385
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1386
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1387
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1388
+ },
1389
+ {
1390
+ "template": "90.1-2007",
1391
+ "cooling_type": "AirCooled",
1392
+ "heating_type": "All Other",
1393
+ "subcategory": "Split System",
1394
+ "minimum_capacity": 135000.0,
1395
+ "maximum_capacity": 239999.0,
1396
+ "minimum_seasonal_efficiency": null,
1397
+ "minimum_full_load_efficiency": 9.1,
1398
+ "minimum_iplv": null,
1399
+ "minimum_integrated_energy_efficiency_ratio": null,
1400
+ "cool_cap_ft": "HPACCoolCapFT",
1401
+ "cool_cap_fflow": "HPACCoolCapFFF",
1402
+ "cool_eir_ft": "HPACCOOLEIRFT",
1403
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1404
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1405
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1406
+ },
1407
+ {
1408
+ "template": "90.1-2007",
1409
+ "cooling_type": "AirCooled",
1410
+ "heating_type": "All Other",
1411
+ "subcategory": "Single Package",
1412
+ "minimum_capacity": 135000.0,
1413
+ "maximum_capacity": 239999.0,
1414
+ "minimum_seasonal_efficiency": null,
1415
+ "minimum_full_load_efficiency": 9.1,
1416
+ "minimum_iplv": null,
1417
+ "minimum_integrated_energy_efficiency_ratio": null,
1418
+ "cool_cap_ft": "HPACCoolCapFT",
1419
+ "cool_cap_fflow": "HPACCoolCapFFF",
1420
+ "cool_eir_ft": "HPACCOOLEIRFT",
1421
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1422
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1423
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1424
+ },
1425
+ {
1426
+ "template": "90.1-2007",
1427
+ "cooling_type": "AirCooled",
1428
+ "heating_type": "Electric Resistance or None",
1429
+ "subcategory": "Split System",
1430
+ "minimum_capacity": 240000.0,
1431
+ "maximum_capacity": 9999999.0,
1432
+ "minimum_seasonal_efficiency": null,
1433
+ "minimum_full_load_efficiency": 9.0,
1434
+ "minimum_iplv": 9.2,
1435
+ "minimum_integrated_energy_efficiency_ratio": null,
1436
+ "cool_cap_ft": "HPACCoolCapFT",
1437
+ "cool_cap_fflow": "HPACCoolCapFFF",
1438
+ "cool_eir_ft": "HPACCOOLEIRFT",
1439
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1440
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1441
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1442
+ },
1443
+ {
1444
+ "template": "90.1-2007",
1445
+ "cooling_type": "AirCooled",
1446
+ "heating_type": "Electric Resistance or None",
1447
+ "subcategory": "Single Package",
1448
+ "minimum_capacity": 240000.0,
1449
+ "maximum_capacity": 9999999.0,
1450
+ "minimum_seasonal_efficiency": null,
1451
+ "minimum_full_load_efficiency": 9.0,
1452
+ "minimum_iplv": 9.2,
1453
+ "minimum_integrated_energy_efficiency_ratio": null,
1454
+ "cool_cap_ft": "HPACCoolCapFT",
1455
+ "cool_cap_fflow": "HPACCoolCapFFF",
1456
+ "cool_eir_ft": "HPACCOOLEIRFT",
1457
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1458
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1459
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1460
+ },
1461
+ {
1462
+ "template": "90.1-2007",
1463
+ "cooling_type": "AirCooled",
1464
+ "heating_type": "All Other",
1465
+ "subcategory": "Split System",
1466
+ "minimum_capacity": 240000.0,
1467
+ "maximum_capacity": 9999999.0,
1468
+ "minimum_seasonal_efficiency": null,
1469
+ "minimum_full_load_efficiency": 8.8,
1470
+ "minimum_iplv": 9.0,
1471
+ "minimum_integrated_energy_efficiency_ratio": null,
1472
+ "cool_cap_ft": "HPACCoolCapFT",
1473
+ "cool_cap_fflow": "HPACCoolCapFFF",
1474
+ "cool_eir_ft": "HPACCOOLEIRFT",
1475
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1476
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1477
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1478
+ },
1479
+ {
1480
+ "template": "90.1-2007",
1481
+ "cooling_type": "AirCooled",
1482
+ "heating_type": "All Other",
1483
+ "subcategory": "Single Package",
1484
+ "minimum_capacity": 240000.0,
1485
+ "maximum_capacity": 9999999.0,
1486
+ "minimum_seasonal_efficiency": null,
1487
+ "minimum_full_load_efficiency": 8.8,
1488
+ "minimum_iplv": 9.0,
1489
+ "minimum_integrated_energy_efficiency_ratio": null,
1490
+ "cool_cap_ft": "HPACCoolCapFT",
1491
+ "cool_cap_fflow": "HPACCoolCapFFF",
1492
+ "cool_eir_ft": "HPACCOOLEIRFT",
1493
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1494
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1495
+ "notes": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010"
1496
+ },
1497
+ {
1498
+ "template": "90.1-2010",
1499
+ "cooling_type": "AirCooled",
1500
+ "heating_type": null,
1501
+ "subcategory": "Split System",
1502
+ "minimum_capacity": 0.0,
1503
+ "maximum_capacity": 64999.0,
1504
+ "minimum_seasonal_efficiency": 13.0,
1505
+ "minimum_full_load_efficiency": null,
1506
+ "minimum_iplv": null,
1507
+ "minimum_integrated_energy_efficiency_ratio": null,
1508
+ "cool_cap_ft": "HPACCoolCapFT",
1509
+ "cool_cap_fflow": "HPACCoolCapFFF",
1510
+ "cool_eir_ft": "HPACCOOLEIRFT",
1511
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1512
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1513
+ "notes": "From 90.1-2010 Table 6.8.1B"
1514
+ },
1515
+ {
1516
+ "template": "90.1-2010",
1517
+ "cooling_type": "AirCooled",
1518
+ "heating_type": null,
1519
+ "subcategory": "Single Package",
1520
+ "minimum_capacity": 0.0,
1521
+ "maximum_capacity": 64999.0,
1522
+ "minimum_seasonal_efficiency": 13.0,
1523
+ "minimum_full_load_efficiency": null,
1524
+ "minimum_iplv": null,
1525
+ "minimum_integrated_energy_efficiency_ratio": null,
1526
+ "cool_cap_ft": "HPACCoolCapFT",
1527
+ "cool_cap_fflow": "HPACCoolCapFFF",
1528
+ "cool_eir_ft": "HPACCOOLEIRFT",
1529
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1530
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1531
+ "notes": "From 90.1-2010 Table 6.8.1B"
1532
+ },
1533
+ {
1534
+ "template": "90.1-2010",
1535
+ "cooling_type": "ThroughWall",
1536
+ "heating_type": null,
1537
+ "subcategory": "Split System",
1538
+ "minimum_capacity": 0.0,
1539
+ "maximum_capacity": 29999.0,
1540
+ "minimum_seasonal_efficiency": 12.0,
1541
+ "minimum_full_load_efficiency": null,
1542
+ "minimum_iplv": null,
1543
+ "minimum_integrated_energy_efficiency_ratio": null,
1544
+ "cool_cap_ft": "HPACCoolCapFT",
1545
+ "cool_cap_fflow": "HPACCoolCapFFF",
1546
+ "cool_eir_ft": "HPACCOOLEIRFT",
1547
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1548
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1549
+ "notes": "From 90.1-2010 Table 6.8.1B"
1550
+ },
1551
+ {
1552
+ "template": "90.1-2010",
1553
+ "cooling_type": "ThroughWall",
1554
+ "heating_type": null,
1555
+ "subcategory": "Single Package",
1556
+ "minimum_capacity": 0.0,
1557
+ "maximum_capacity": 29999.0,
1558
+ "minimum_seasonal_efficiency": 12.0,
1559
+ "minimum_full_load_efficiency": null,
1560
+ "minimum_iplv": null,
1561
+ "minimum_integrated_energy_efficiency_ratio": null,
1562
+ "cool_cap_ft": "HPACCoolCapFT",
1563
+ "cool_cap_fflow": "HPACCoolCapFFF",
1564
+ "cool_eir_ft": "HPACCOOLEIRFT",
1565
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1566
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1567
+ "notes": "From 90.1-2010 Table 6.8.1B"
1568
+ },
1569
+ {
1570
+ "template": "90.1-2010",
1571
+ "cooling_type": "AirCooled",
1572
+ "heating_type": "Electric Resistance or None",
1573
+ "subcategory": "Split System",
1574
+ "minimum_capacity": 65000.0,
1575
+ "maximum_capacity": 134999.0,
1576
+ "minimum_seasonal_efficiency": null,
1577
+ "minimum_full_load_efficiency": 11.0,
1578
+ "minimum_iplv": null,
1579
+ "minimum_integrated_energy_efficiency_ratio": 11.2,
1580
+ "cool_cap_ft": "HPACCoolCapFT",
1581
+ "cool_cap_fflow": "HPACCoolCapFFF",
1582
+ "cool_eir_ft": "HPACCOOLEIRFT",
1583
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1584
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1585
+ "notes": "From 90.1-2010 Table 6.8.1B"
1586
+ },
1587
+ {
1588
+ "template": "90.1-2010",
1589
+ "cooling_type": "AirCooled",
1590
+ "heating_type": "Electric Resistance or None",
1591
+ "subcategory": "Single Package",
1592
+ "minimum_capacity": 65000.0,
1593
+ "maximum_capacity": 134999.0,
1594
+ "minimum_seasonal_efficiency": null,
1595
+ "minimum_full_load_efficiency": 11.0,
1596
+ "minimum_iplv": null,
1597
+ "minimum_integrated_energy_efficiency_ratio": 11.2,
1598
+ "cool_cap_ft": "HPACCoolCapFT",
1599
+ "cool_cap_fflow": "HPACCoolCapFFF",
1600
+ "cool_eir_ft": "HPACCOOLEIRFT",
1601
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1602
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1603
+ "notes": "From 90.1-2010 Table 6.8.1B"
1604
+ },
1605
+ {
1606
+ "template": "90.1-2010",
1607
+ "cooling_type": "AirCooled",
1608
+ "heating_type": "All Other",
1609
+ "subcategory": "Split System",
1610
+ "minimum_capacity": 65000.0,
1611
+ "maximum_capacity": 134999.0,
1612
+ "minimum_seasonal_efficiency": null,
1613
+ "minimum_full_load_efficiency": 10.8,
1614
+ "minimum_iplv": null,
1615
+ "minimum_integrated_energy_efficiency_ratio": 11.0,
1616
+ "cool_cap_ft": "HPACCoolCapFT",
1617
+ "cool_cap_fflow": "HPACCoolCapFFF",
1618
+ "cool_eir_ft": "HPACCOOLEIRFT",
1619
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1620
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1621
+ "notes": "From 90.1-2010 Table 6.8.1B"
1622
+ },
1623
+ {
1624
+ "template": "90.1-2010",
1625
+ "cooling_type": "AirCooled",
1626
+ "heating_type": "All Other",
1627
+ "subcategory": "Single Package",
1628
+ "minimum_capacity": 65000.0,
1629
+ "maximum_capacity": 134999.0,
1630
+ "minimum_seasonal_efficiency": null,
1631
+ "minimum_full_load_efficiency": 10.8,
1632
+ "minimum_iplv": null,
1633
+ "minimum_integrated_energy_efficiency_ratio": 11.0,
1634
+ "cool_cap_ft": "HPACCoolCapFT",
1635
+ "cool_cap_fflow": "HPACCoolCapFFF",
1636
+ "cool_eir_ft": "HPACCOOLEIRFT",
1637
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1638
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1639
+ "notes": "From 90.1-2010 Table 6.8.1B"
1640
+ },
1641
+ {
1642
+ "template": "90.1-2010",
1643
+ "cooling_type": "AirCooled",
1644
+ "heating_type": "Electric Resistance or None",
1645
+ "subcategory": "Split System",
1646
+ "minimum_capacity": 135000.0,
1647
+ "maximum_capacity": 239999.0,
1648
+ "minimum_seasonal_efficiency": null,
1649
+ "minimum_full_load_efficiency": 10.6,
1650
+ "minimum_iplv": null,
1651
+ "minimum_integrated_energy_efficiency_ratio": 10.7,
1652
+ "cool_cap_ft": "HPACCoolCapFT",
1653
+ "cool_cap_fflow": "HPACCoolCapFFF",
1654
+ "cool_eir_ft": "HPACCOOLEIRFT",
1655
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1656
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1657
+ "notes": "From 90.1-2010 Table 6.8.1B"
1658
+ },
1659
+ {
1660
+ "template": "90.1-2010",
1661
+ "cooling_type": "AirCooled",
1662
+ "heating_type": "Electric Resistance or None",
1663
+ "subcategory": "Single Package",
1664
+ "minimum_capacity": 135000.0,
1665
+ "maximum_capacity": 239999.0,
1666
+ "minimum_seasonal_efficiency": null,
1667
+ "minimum_full_load_efficiency": 10.6,
1668
+ "minimum_iplv": null,
1669
+ "minimum_integrated_energy_efficiency_ratio": 10.7,
1670
+ "cool_cap_ft": "HPACCoolCapFT",
1671
+ "cool_cap_fflow": "HPACCoolCapFFF",
1672
+ "cool_eir_ft": "HPACCOOLEIRFT",
1673
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1674
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1675
+ "notes": "From 90.1-2010 Table 6.8.1B"
1676
+ },
1677
+ {
1678
+ "template": "90.1-2010",
1679
+ "cooling_type": "AirCooled",
1680
+ "heating_type": "All Other",
1681
+ "subcategory": "Split System",
1682
+ "minimum_capacity": 135000.0,
1683
+ "maximum_capacity": 239999.0,
1684
+ "minimum_seasonal_efficiency": null,
1685
+ "minimum_full_load_efficiency": 10.4,
1686
+ "minimum_iplv": null,
1687
+ "minimum_integrated_energy_efficiency_ratio": 10.5,
1688
+ "cool_cap_ft": "HPACCoolCapFT",
1689
+ "cool_cap_fflow": "HPACCoolCapFFF",
1690
+ "cool_eir_ft": "HPACCOOLEIRFT",
1691
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1692
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1693
+ "notes": "From 90.1-2010 Table 6.8.1B"
1694
+ },
1695
+ {
1696
+ "template": "90.1-2010",
1697
+ "cooling_type": "AirCooled",
1698
+ "heating_type": "All Other",
1699
+ "subcategory": "Single Package",
1700
+ "minimum_capacity": 135000.0,
1701
+ "maximum_capacity": 239999.0,
1702
+ "minimum_seasonal_efficiency": null,
1703
+ "minimum_full_load_efficiency": 10.4,
1704
+ "minimum_iplv": null,
1705
+ "minimum_integrated_energy_efficiency_ratio": 10.5,
1706
+ "cool_cap_ft": "HPACCoolCapFT",
1707
+ "cool_cap_fflow": "HPACCoolCapFFF",
1708
+ "cool_eir_ft": "HPACCOOLEIRFT",
1709
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1710
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1711
+ "notes": "From 90.1-2010 Table 6.8.1B"
1712
+ },
1713
+ {
1714
+ "template": "90.1-2010",
1715
+ "cooling_type": "AirCooled",
1716
+ "heating_type": "Electric Resistance or None",
1717
+ "subcategory": "Split System",
1718
+ "minimum_capacity": 240000.0,
1719
+ "maximum_capacity": 9999999.0,
1720
+ "minimum_seasonal_efficiency": null,
1721
+ "minimum_full_load_efficiency": 9.5,
1722
+ "minimum_iplv": null,
1723
+ "minimum_integrated_energy_efficiency_ratio": 9.6,
1724
+ "cool_cap_ft": "HPACCoolCapFT",
1725
+ "cool_cap_fflow": "HPACCoolCapFFF",
1726
+ "cool_eir_ft": "HPACCOOLEIRFT",
1727
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1728
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1729
+ "notes": "From 90.1-2010 Table 6.8.1B"
1730
+ },
1731
+ {
1732
+ "template": "90.1-2010",
1733
+ "cooling_type": "AirCooled",
1734
+ "heating_type": "Electric Resistance or None",
1735
+ "subcategory": "Single Package",
1736
+ "minimum_capacity": 240000.0,
1737
+ "maximum_capacity": 9999999.0,
1738
+ "minimum_seasonal_efficiency": null,
1739
+ "minimum_full_load_efficiency": 9.5,
1740
+ "minimum_iplv": null,
1741
+ "minimum_integrated_energy_efficiency_ratio": 9.6,
1742
+ "cool_cap_ft": "HPACCoolCapFT",
1743
+ "cool_cap_fflow": "HPACCoolCapFFF",
1744
+ "cool_eir_ft": "HPACCOOLEIRFT",
1745
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1746
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1747
+ "notes": "From 90.1-2010 Table 6.8.1B"
1748
+ },
1749
+ {
1750
+ "template": "90.1-2010",
1751
+ "cooling_type": "AirCooled",
1752
+ "heating_type": "All Other",
1753
+ "subcategory": "Split System",
1754
+ "minimum_capacity": 240000.0,
1755
+ "maximum_capacity": 9999999.0,
1756
+ "minimum_seasonal_efficiency": null,
1757
+ "minimum_full_load_efficiency": 9.3,
1758
+ "minimum_iplv": null,
1759
+ "minimum_integrated_energy_efficiency_ratio": 9.4,
1760
+ "cool_cap_ft": "HPACCoolCapFT",
1761
+ "cool_cap_fflow": "HPACCoolCapFFF",
1762
+ "cool_eir_ft": "HPACCOOLEIRFT",
1763
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1764
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1765
+ "notes": "From 90.1-2010 Table 6.8.1B"
1766
+ },
1767
+ {
1768
+ "template": "90.1-2010",
1769
+ "cooling_type": "AirCooled",
1770
+ "heating_type": "All Other",
1771
+ "subcategory": "Single Package",
1772
+ "minimum_capacity": 240000.0,
1773
+ "maximum_capacity": 9999999.0,
1774
+ "minimum_seasonal_efficiency": null,
1775
+ "minimum_full_load_efficiency": 9.3,
1776
+ "minimum_iplv": null,
1777
+ "minimum_integrated_energy_efficiency_ratio": 9.4,
1778
+ "cool_cap_ft": "HPACCoolCapFT",
1779
+ "cool_cap_fflow": "HPACCoolCapFFF",
1780
+ "cool_eir_ft": "HPACCOOLEIRFT",
1781
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1782
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1783
+ "notes": "From 90.1-2010 Table 6.8.1B"
1784
+ },
1785
+ {
1786
+ "template": "90.1-2013",
1787
+ "cooling_type": "AirCooled",
1788
+ "heating_type": null,
1789
+ "subcategory": "Split System",
1790
+ "minimum_capacity": 0.0,
1791
+ "maximum_capacity": 64999.0,
1792
+ "minimum_seasonal_efficiency": 13.0,
1793
+ "minimum_full_load_efficiency": null,
1794
+ "minimum_iplv": null,
1795
+ "minimum_integrated_energy_efficiency_ratio": null,
1796
+ "cool_cap_ft": "HPACCoolCapFT",
1797
+ "cool_cap_fflow": "HPACCoolCapFFF",
1798
+ "cool_eir_ft": "HPACCOOLEIRFT",
1799
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1800
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1801
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2015"
1802
+ },
1803
+ {
1804
+ "template": "90.1-2013",
1805
+ "cooling_type": "AirCooled",
1806
+ "heating_type": null,
1807
+ "subcategory": "Single Package",
1808
+ "minimum_capacity": 0.0,
1809
+ "maximum_capacity": 64999.0,
1810
+ "minimum_seasonal_efficiency": 13.0,
1811
+ "minimum_full_load_efficiency": null,
1812
+ "minimum_iplv": null,
1813
+ "minimum_integrated_energy_efficiency_ratio": null,
1814
+ "cool_cap_ft": "HPACCoolCapFT",
1815
+ "cool_cap_fflow": "HPACCoolCapFFF",
1816
+ "cool_eir_ft": "HPACCOOLEIRFT",
1817
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1818
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1819
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2015"
1820
+ },
1821
+ {
1822
+ "template": "90.1-2013",
1823
+ "cooling_type": "ThroughWall",
1824
+ "heating_type": null,
1825
+ "subcategory": "Split System",
1826
+ "minimum_capacity": 0.0,
1827
+ "maximum_capacity": 29999.0,
1828
+ "minimum_seasonal_efficiency": 12.0,
1829
+ "minimum_full_load_efficiency": null,
1830
+ "minimum_iplv": null,
1831
+ "minimum_integrated_energy_efficiency_ratio": null,
1832
+ "cool_cap_ft": "HPACCoolCapFT",
1833
+ "cool_cap_fflow": "HPACCoolCapFFF",
1834
+ "cool_eir_ft": "HPACCOOLEIRFT",
1835
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1836
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1837
+ "notes": "From 90.1-2010 Table 6.8.1-2"
1838
+ },
1839
+ {
1840
+ "template": "90.1-2013",
1841
+ "cooling_type": "ThroughWall",
1842
+ "heating_type": null,
1843
+ "subcategory": "Single Package",
1844
+ "minimum_capacity": 0.0,
1845
+ "maximum_capacity": 29999.0,
1846
+ "minimum_seasonal_efficiency": 12.0,
1847
+ "minimum_full_load_efficiency": null,
1848
+ "minimum_iplv": null,
1849
+ "minimum_integrated_energy_efficiency_ratio": null,
1850
+ "cool_cap_ft": "HPACCoolCapFT",
1851
+ "cool_cap_fflow": "HPACCoolCapFFF",
1852
+ "cool_eir_ft": "HPACCOOLEIRFT",
1853
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1854
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1855
+ "notes": "From 90.1-2010 Table 6.8.1-2"
1856
+ },
1857
+ {
1858
+ "template": "90.1-2013",
1859
+ "cooling_type": "SmallDuctHighVelocity",
1860
+ "heating_type": null,
1861
+ "subcategory": "Split System",
1862
+ "minimum_capacity": 0.0,
1863
+ "maximum_capacity": 64999.0,
1864
+ "minimum_seasonal_efficiency": 11.0,
1865
+ "minimum_full_load_efficiency": null,
1866
+ "minimum_iplv": null,
1867
+ "minimum_integrated_energy_efficiency_ratio": null,
1868
+ "cool_cap_ft": "HPACCoolCapFT",
1869
+ "cool_cap_fflow": "HPACCoolCapFFF",
1870
+ "cool_eir_ft": "HPACCOOLEIRFT",
1871
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1872
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1873
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
1874
+ },
1875
+ {
1876
+ "template": "90.1-2013",
1877
+ "cooling_type": "AirCooled",
1878
+ "heating_type": "Electric Resistance or None",
1879
+ "subcategory": "Split System",
1880
+ "minimum_capacity": 65000.0,
1881
+ "maximum_capacity": 134999.0,
1882
+ "minimum_seasonal_efficiency": null,
1883
+ "minimum_full_load_efficiency": 11.0,
1884
+ "minimum_iplv": null,
1885
+ "minimum_integrated_energy_efficiency_ratio": 11.2,
1886
+ "cool_cap_ft": "HPACCoolCapFT",
1887
+ "cool_cap_fflow": "HPACCoolCapFFF",
1888
+ "cool_eir_ft": "HPACCOOLEIRFT",
1889
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1890
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1891
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
1892
+ },
1893
+ {
1894
+ "template": "90.1-2013",
1895
+ "cooling_type": "AirCooled",
1896
+ "heating_type": "Electric Resistance or None",
1897
+ "subcategory": "Single Package",
1898
+ "minimum_capacity": 65000.0,
1899
+ "maximum_capacity": 134999.0,
1900
+ "minimum_seasonal_efficiency": null,
1901
+ "minimum_full_load_efficiency": 11.0,
1902
+ "minimum_iplv": null,
1903
+ "minimum_integrated_energy_efficiency_ratio": 11.2,
1904
+ "cool_cap_ft": "HPACCoolCapFT",
1905
+ "cool_cap_fflow": "HPACCoolCapFFF",
1906
+ "cool_eir_ft": "HPACCOOLEIRFT",
1907
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1908
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1909
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
1910
+ },
1911
+ {
1912
+ "template": "90.1-2013",
1913
+ "cooling_type": "AirCooled",
1914
+ "heating_type": "All Other",
1915
+ "subcategory": "Split System",
1916
+ "minimum_capacity": 65000.0,
1917
+ "maximum_capacity": 134999.0,
1918
+ "minimum_seasonal_efficiency": null,
1919
+ "minimum_full_load_efficiency": 10.8,
1920
+ "minimum_iplv": null,
1921
+ "minimum_integrated_energy_efficiency_ratio": 11.0,
1922
+ "cool_cap_ft": "HPACCoolCapFT",
1923
+ "cool_cap_fflow": "HPACCoolCapFFF",
1924
+ "cool_eir_ft": "HPACCOOLEIRFT",
1925
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1926
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1927
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
1928
+ },
1929
+ {
1930
+ "template": "90.1-2013",
1931
+ "cooling_type": "AirCooled",
1932
+ "heating_type": "All Other",
1933
+ "subcategory": "Single Package",
1934
+ "minimum_capacity": 65000.0,
1935
+ "maximum_capacity": 134999.0,
1936
+ "minimum_seasonal_efficiency": null,
1937
+ "minimum_full_load_efficiency": 10.8,
1938
+ "minimum_iplv": null,
1939
+ "minimum_integrated_energy_efficiency_ratio": 11.0,
1940
+ "cool_cap_ft": "HPACCoolCapFT",
1941
+ "cool_cap_fflow": "HPACCoolCapFFF",
1942
+ "cool_eir_ft": "HPACCOOLEIRFT",
1943
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1944
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1945
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
1946
+ },
1947
+ {
1948
+ "template": "90.1-2013",
1949
+ "cooling_type": "AirCooled",
1950
+ "heating_type": "Electric Resistance or None",
1951
+ "subcategory": "Split System",
1952
+ "minimum_capacity": 135000.0,
1953
+ "maximum_capacity": 239999.0,
1954
+ "minimum_seasonal_efficiency": null,
1955
+ "minimum_full_load_efficiency": 10.6,
1956
+ "minimum_iplv": null,
1957
+ "minimum_integrated_energy_efficiency_ratio": 10.7,
1958
+ "cool_cap_ft": "HPACCoolCapFT",
1959
+ "cool_cap_fflow": "HPACCoolCapFFF",
1960
+ "cool_eir_ft": "HPACCOOLEIRFT",
1961
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1962
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1963
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
1964
+ },
1965
+ {
1966
+ "template": "90.1-2013",
1967
+ "cooling_type": "AirCooled",
1968
+ "heating_type": "Electric Resistance or None",
1969
+ "subcategory": "Single Package",
1970
+ "minimum_capacity": 135000.0,
1971
+ "maximum_capacity": 239999.0,
1972
+ "minimum_seasonal_efficiency": null,
1973
+ "minimum_full_load_efficiency": 10.6,
1974
+ "minimum_iplv": null,
1975
+ "minimum_integrated_energy_efficiency_ratio": 10.7,
1976
+ "cool_cap_ft": "HPACCoolCapFT",
1977
+ "cool_cap_fflow": "HPACCoolCapFFF",
1978
+ "cool_eir_ft": "HPACCOOLEIRFT",
1979
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1980
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1981
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
1982
+ },
1983
+ {
1984
+ "template": "90.1-2013",
1985
+ "cooling_type": "AirCooled",
1986
+ "heating_type": "All Other",
1987
+ "subcategory": "Split System",
1988
+ "minimum_capacity": 135000.0,
1989
+ "maximum_capacity": 239999.0,
1990
+ "minimum_seasonal_efficiency": null,
1991
+ "minimum_full_load_efficiency": 10.4,
1992
+ "minimum_iplv": null,
1993
+ "minimum_integrated_energy_efficiency_ratio": 10.5,
1994
+ "cool_cap_ft": "HPACCoolCapFT",
1995
+ "cool_cap_fflow": "HPACCoolCapFFF",
1996
+ "cool_eir_ft": "HPACCOOLEIRFT",
1997
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
1998
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
1999
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
2000
+ },
2001
+ {
2002
+ "template": "90.1-2013",
2003
+ "cooling_type": "AirCooled",
2004
+ "heating_type": "All Other",
2005
+ "subcategory": "Single Package",
2006
+ "minimum_capacity": 135000.0,
2007
+ "maximum_capacity": 239999.0,
2008
+ "minimum_seasonal_efficiency": null,
2009
+ "minimum_full_load_efficiency": 10.4,
2010
+ "minimum_iplv": null,
2011
+ "minimum_integrated_energy_efficiency_ratio": 10.5,
2012
+ "cool_cap_ft": "HPACCoolCapFT",
2013
+ "cool_cap_fflow": "HPACCoolCapFFF",
2014
+ "cool_eir_ft": "HPACCOOLEIRFT",
2015
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2016
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2017
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
2018
+ },
2019
+ {
2020
+ "template": "90.1-2013",
2021
+ "cooling_type": "AirCooled",
2022
+ "heating_type": "Electric Resistance or None",
2023
+ "subcategory": "Split System",
2024
+ "minimum_capacity": 240000.0,
2025
+ "maximum_capacity": 9999999.0,
2026
+ "minimum_seasonal_efficiency": null,
2027
+ "minimum_full_load_efficiency": 9.5,
2028
+ "minimum_iplv": null,
2029
+ "minimum_integrated_energy_efficiency_ratio": 9.6,
2030
+ "cool_cap_ft": "HPACCoolCapFT",
2031
+ "cool_cap_fflow": "HPACCoolCapFFF",
2032
+ "cool_eir_ft": "HPACCOOLEIRFT",
2033
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2034
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2035
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
2036
+ },
2037
+ {
2038
+ "template": "90.1-2013",
2039
+ "cooling_type": "AirCooled",
2040
+ "heating_type": "Electric Resistance or None",
2041
+ "subcategory": "Single Package",
2042
+ "minimum_capacity": 240000.0,
2043
+ "maximum_capacity": 9999999.0,
2044
+ "minimum_seasonal_efficiency": null,
2045
+ "minimum_full_load_efficiency": 9.5,
2046
+ "minimum_iplv": null,
2047
+ "minimum_integrated_energy_efficiency_ratio": 9.6,
2048
+ "cool_cap_ft": "HPACCoolCapFT",
2049
+ "cool_cap_fflow": "HPACCoolCapFFF",
2050
+ "cool_eir_ft": "HPACCOOLEIRFT",
2051
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2052
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2053
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
2054
+ },
2055
+ {
2056
+ "template": "90.1-2013",
2057
+ "cooling_type": "AirCooled",
2058
+ "heating_type": "All Other",
2059
+ "subcategory": "Split System",
2060
+ "minimum_capacity": 240000.0,
2061
+ "maximum_capacity": 9999999.0,
2062
+ "minimum_seasonal_efficiency": null,
2063
+ "minimum_full_load_efficiency": 9.3,
2064
+ "minimum_iplv": null,
2065
+ "minimum_integrated_energy_efficiency_ratio": 9.4,
2066
+ "cool_cap_ft": "HPACCoolCapFT",
2067
+ "cool_cap_fflow": "HPACCoolCapFFF",
2068
+ "cool_eir_ft": "HPACCOOLEIRFT",
2069
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2070
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2071
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
2072
+ },
2073
+ {
2074
+ "template": "90.1-2013",
2075
+ "cooling_type": "AirCooled",
2076
+ "heating_type": "All Other",
2077
+ "subcategory": "Single Package",
2078
+ "minimum_capacity": 240000.0,
2079
+ "maximum_capacity": 9999999.0,
2080
+ "minimum_seasonal_efficiency": null,
2081
+ "minimum_full_load_efficiency": 9.3,
2082
+ "minimum_iplv": null,
2083
+ "minimum_integrated_energy_efficiency_ratio": 9.4,
2084
+ "cool_cap_ft": "HPACCoolCapFT",
2085
+ "cool_cap_fflow": "HPACCoolCapFFF",
2086
+ "cool_eir_ft": "HPACCOOLEIRFT",
2087
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2088
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2089
+ "notes": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016"
2090
+ },
2091
+ {
2092
+ "template": "OEESC 2014",
2093
+ "cooling_type": "AirCooled",
2094
+ "heating_type": null,
2095
+ "subcategory": "Split System",
2096
+ "minimum_capacity": 0.0,
2097
+ "maximum_capacity": 64999.0,
2098
+ "minimum_seasonal_efficiency": 14.0,
2099
+ "minimum_full_load_efficiency": null,
2100
+ "minimum_iplv": null,
2101
+ "minimum_integrated_energy_efficiency_ratio": null,
2102
+ "cool_cap_ft": "HPACCoolCapFT",
2103
+ "cool_cap_fflow": "HPACCoolCapFFF",
2104
+ "cool_eir_ft": "HPACCOOLEIRFT",
2105
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2106
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2107
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2108
+ },
2109
+ {
2110
+ "template": "OEESC 2014",
2111
+ "cooling_type": "AirCooled",
2112
+ "heating_type": null,
2113
+ "subcategory": "Single Package",
2114
+ "minimum_capacity": 0.0,
2115
+ "maximum_capacity": 64999.0,
2116
+ "minimum_seasonal_efficiency": 14.0,
2117
+ "minimum_full_load_efficiency": null,
2118
+ "minimum_iplv": null,
2119
+ "minimum_integrated_energy_efficiency_ratio": null,
2120
+ "cool_cap_ft": "HPACCoolCapFT",
2121
+ "cool_cap_fflow": "HPACCoolCapFFF",
2122
+ "cool_eir_ft": "HPACCOOLEIRFT",
2123
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2124
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2125
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2126
+ },
2127
+ {
2128
+ "template": "OEESC 2014",
2129
+ "cooling_type": "ThroughWall",
2130
+ "heating_type": null,
2131
+ "subcategory": "Split System",
2132
+ "minimum_capacity": 0.0,
2133
+ "maximum_capacity": 29999.0,
2134
+ "minimum_seasonal_efficiency": 12.0,
2135
+ "minimum_full_load_efficiency": null,
2136
+ "minimum_iplv": null,
2137
+ "minimum_integrated_energy_efficiency_ratio": null,
2138
+ "cool_cap_ft": "HPACCoolCapFT",
2139
+ "cool_cap_fflow": "HPACCoolCapFFF",
2140
+ "cool_eir_ft": "HPACCOOLEIRFT",
2141
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2142
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2143
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2144
+ },
2145
+ {
2146
+ "template": "OEESC 2014",
2147
+ "cooling_type": "ThroughWall",
2148
+ "heating_type": null,
2149
+ "subcategory": "Single Package",
2150
+ "minimum_capacity": 0.0,
2151
+ "maximum_capacity": 29999.0,
2152
+ "minimum_seasonal_efficiency": 12.0,
2153
+ "minimum_full_load_efficiency": null,
2154
+ "minimum_iplv": null,
2155
+ "minimum_integrated_energy_efficiency_ratio": null,
2156
+ "cool_cap_ft": "HPACCoolCapFT",
2157
+ "cool_cap_fflow": "HPACCoolCapFFF",
2158
+ "cool_eir_ft": "HPACCOOLEIRFT",
2159
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2160
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2161
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2162
+ },
2163
+ {
2164
+ "template": "OEESC 2014",
2165
+ "cooling_type": "SmallDuctHighVelocity",
2166
+ "heating_type": null,
2167
+ "subcategory": "Split System",
2168
+ "minimum_capacity": 0.0,
2169
+ "maximum_capacity": 64999.0,
2170
+ "minimum_seasonal_efficiency": 11.0,
2171
+ "minimum_full_load_efficiency": null,
2172
+ "minimum_iplv": null,
2173
+ "minimum_integrated_energy_efficiency_ratio": null,
2174
+ "cool_cap_ft": "HPACCoolCapFT",
2175
+ "cool_cap_fflow": "HPACCoolCapFFF",
2176
+ "cool_eir_ft": "HPACCOOLEIRFT",
2177
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2178
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2179
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2180
+ },
2181
+ {
2182
+ "template": "OEESC 2014",
2183
+ "cooling_type": "AirCooled",
2184
+ "heating_type": "Electric Resistance or None",
2185
+ "subcategory": "Split System",
2186
+ "minimum_capacity": 65000.0,
2187
+ "maximum_capacity": 134999.0,
2188
+ "minimum_seasonal_efficiency": null,
2189
+ "minimum_full_load_efficiency": 11.0,
2190
+ "minimum_iplv": null,
2191
+ "minimum_integrated_energy_efficiency_ratio": 11.2,
2192
+ "cool_cap_ft": "HPACCoolCapFT",
2193
+ "cool_cap_fflow": "HPACCoolCapFFF",
2194
+ "cool_eir_ft": "HPACCOOLEIRFT",
2195
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2196
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2197
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2198
+ },
2199
+ {
2200
+ "template": "OEESC 2014",
2201
+ "cooling_type": "AirCooled",
2202
+ "heating_type": "Electric Resistance or None",
2203
+ "subcategory": "Single Package",
2204
+ "minimum_capacity": 65000.0,
2205
+ "maximum_capacity": 134999.0,
2206
+ "minimum_seasonal_efficiency": null,
2207
+ "minimum_full_load_efficiency": 11.0,
2208
+ "minimum_iplv": null,
2209
+ "minimum_integrated_energy_efficiency_ratio": 11.2,
2210
+ "cool_cap_ft": "HPACCoolCapFT",
2211
+ "cool_cap_fflow": "HPACCoolCapFFF",
2212
+ "cool_eir_ft": "HPACCOOLEIRFT",
2213
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2214
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2215
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2216
+ },
2217
+ {
2218
+ "template": "OEESC 2014",
2219
+ "cooling_type": "AirCooled",
2220
+ "heating_type": "All Other",
2221
+ "subcategory": "Split System",
2222
+ "minimum_capacity": 65000.0,
2223
+ "maximum_capacity": 134999.0,
2224
+ "minimum_seasonal_efficiency": null,
2225
+ "minimum_full_load_efficiency": 10.8,
2226
+ "minimum_iplv": null,
2227
+ "minimum_integrated_energy_efficiency_ratio": 11.0,
2228
+ "cool_cap_ft": "HPACCoolCapFT",
2229
+ "cool_cap_fflow": "HPACCoolCapFFF",
2230
+ "cool_eir_ft": "HPACCOOLEIRFT",
2231
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2232
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2233
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2234
+ },
2235
+ {
2236
+ "template": "OEESC 2014",
2237
+ "cooling_type": "AirCooled",
2238
+ "heating_type": "All Other",
2239
+ "subcategory": "Single Package",
2240
+ "minimum_capacity": 65000.0,
2241
+ "maximum_capacity": 134999.0,
2242
+ "minimum_seasonal_efficiency": null,
2243
+ "minimum_full_load_efficiency": 10.8,
2244
+ "minimum_iplv": null,
2245
+ "minimum_integrated_energy_efficiency_ratio": 11.0,
2246
+ "cool_cap_ft": "HPACCoolCapFT",
2247
+ "cool_cap_fflow": "HPACCoolCapFFF",
2248
+ "cool_eir_ft": "HPACCOOLEIRFT",
2249
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2250
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2251
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2252
+ },
2253
+ {
2254
+ "template": "OEESC 2014",
2255
+ "cooling_type": "AirCooled",
2256
+ "heating_type": "Electric Resistance or None",
2257
+ "subcategory": "Split System",
2258
+ "minimum_capacity": 135000.0,
2259
+ "maximum_capacity": 239999.0,
2260
+ "minimum_seasonal_efficiency": null,
2261
+ "minimum_full_load_efficiency": 10.6,
2262
+ "minimum_iplv": null,
2263
+ "minimum_integrated_energy_efficiency_ratio": 10.7,
2264
+ "cool_cap_ft": "HPACCoolCapFT",
2265
+ "cool_cap_fflow": "HPACCoolCapFFF",
2266
+ "cool_eir_ft": "HPACCOOLEIRFT",
2267
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2268
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2269
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2270
+ },
2271
+ {
2272
+ "template": "OEESC 2014",
2273
+ "cooling_type": "AirCooled",
2274
+ "heating_type": "Electric Resistance or None",
2275
+ "subcategory": "Single Package",
2276
+ "minimum_capacity": 135000.0,
2277
+ "maximum_capacity": 239999.0,
2278
+ "minimum_seasonal_efficiency": null,
2279
+ "minimum_full_load_efficiency": 10.6,
2280
+ "minimum_iplv": null,
2281
+ "minimum_integrated_energy_efficiency_ratio": 10.7,
2282
+ "cool_cap_ft": "HPACCoolCapFT",
2283
+ "cool_cap_fflow": "HPACCoolCapFFF",
2284
+ "cool_eir_ft": "HPACCOOLEIRFT",
2285
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2286
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2287
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2288
+ },
2289
+ {
2290
+ "template": "OEESC 2014",
2291
+ "cooling_type": "AirCooled",
2292
+ "heating_type": "All Other",
2293
+ "subcategory": "Split System",
2294
+ "minimum_capacity": 135000.0,
2295
+ "maximum_capacity": 239999.0,
2296
+ "minimum_seasonal_efficiency": null,
2297
+ "minimum_full_load_efficiency": 10.4,
2298
+ "minimum_iplv": null,
2299
+ "minimum_integrated_energy_efficiency_ratio": 10.5,
2300
+ "cool_cap_ft": "HPACCoolCapFT",
2301
+ "cool_cap_fflow": "HPACCoolCapFFF",
2302
+ "cool_eir_ft": "HPACCOOLEIRFT",
2303
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2304
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2305
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2306
+ },
2307
+ {
2308
+ "template": "OEESC 2014",
2309
+ "cooling_type": "AirCooled",
2310
+ "heating_type": "All Other",
2311
+ "subcategory": "Single Package",
2312
+ "minimum_capacity": 135000.0,
2313
+ "maximum_capacity": 239999.0,
2314
+ "minimum_seasonal_efficiency": null,
2315
+ "minimum_full_load_efficiency": 10.4,
2316
+ "minimum_iplv": null,
2317
+ "minimum_integrated_energy_efficiency_ratio": 10.5,
2318
+ "cool_cap_ft": "HPACCoolCapFT",
2319
+ "cool_cap_fflow": "HPACCoolCapFFF",
2320
+ "cool_eir_ft": "HPACCOOLEIRFT",
2321
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2322
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2323
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2324
+ },
2325
+ {
2326
+ "template": "OEESC 2014",
2327
+ "cooling_type": "AirCooled",
2328
+ "heating_type": "Electric Resistance or None",
2329
+ "subcategory": "Split System",
2330
+ "minimum_capacity": 240000.0,
2331
+ "maximum_capacity": 9999999.0,
2332
+ "minimum_seasonal_efficiency": null,
2333
+ "minimum_full_load_efficiency": 9.5,
2334
+ "minimum_iplv": null,
2335
+ "minimum_integrated_energy_efficiency_ratio": 9.6,
2336
+ "cool_cap_ft": "HPACCoolCapFT",
2337
+ "cool_cap_fflow": "HPACCoolCapFFF",
2338
+ "cool_eir_ft": "HPACCOOLEIRFT",
2339
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2340
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2341
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2342
+ },
2343
+ {
2344
+ "template": "OEESC 2014",
2345
+ "cooling_type": "AirCooled",
2346
+ "heating_type": "Electric Resistance or None",
2347
+ "subcategory": "Single Package",
2348
+ "minimum_capacity": 240000.0,
2349
+ "maximum_capacity": 9999999.0,
2350
+ "minimum_seasonal_efficiency": null,
2351
+ "minimum_full_load_efficiency": 9.5,
2352
+ "minimum_iplv": null,
2353
+ "minimum_integrated_energy_efficiency_ratio": 9.6,
2354
+ "cool_cap_ft": "HPACCoolCapFT",
2355
+ "cool_cap_fflow": "HPACCoolCapFFF",
2356
+ "cool_eir_ft": "HPACCOOLEIRFT",
2357
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2358
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2359
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2360
+ },
2361
+ {
2362
+ "template": "OEESC 2014",
2363
+ "cooling_type": "AirCooled",
2364
+ "heating_type": "All Other",
2365
+ "subcategory": "Split System",
2366
+ "minimum_capacity": 240000.0,
2367
+ "maximum_capacity": 9999999.0,
2368
+ "minimum_seasonal_efficiency": null,
2369
+ "minimum_full_load_efficiency": 9.3,
2370
+ "minimum_iplv": null,
2371
+ "minimum_integrated_energy_efficiency_ratio": 9.4,
2372
+ "cool_cap_ft": "HPACCoolCapFT",
2373
+ "cool_cap_fflow": "HPACCoolCapFFF",
2374
+ "cool_eir_ft": "HPACCOOLEIRFT",
2375
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2376
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2377
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
2378
+ },
2379
+ {
2380
+ "template": "OEESC 2014",
2381
+ "cooling_type": "AirCooled",
2382
+ "heating_type": "All Other",
2383
+ "subcategory": "Single Package",
2384
+ "minimum_capacity": 240000.0,
2385
+ "maximum_capacity": 9999999.0,
2386
+ "minimum_seasonal_efficiency": null,
2387
+ "minimum_full_load_efficiency": 9.3,
2388
+ "minimum_iplv": null,
2389
+ "minimum_integrated_energy_efficiency_ratio": 9.4,
2390
+ "cool_cap_ft": "HPACCoolCapFT",
2391
+ "cool_cap_fflow": "HPACCoolCapFFF",
2392
+ "cool_eir_ft": "HPACCOOLEIRFT",
2393
+ "cool_eir_fflow": "HPACCOOLEIRFFF",
2394
+ "cool_plf_fplr": "HPACCOOLPLFFPLR",
2395
+ "notes": "From OEESC 2014 Table 503.2.3(2) Before 1/1/2016"
342
2396
  }
343
2397
  ]
344
2398
  }