openstudio-calibration 0.1.2

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (218) hide show
  1. checksums.yaml +7 -0
  2. data/.gitignore +29 -0
  3. data/CHANGELOG.md +14 -0
  4. data/Gemfile +20 -0
  5. data/Jenkinsfile +6 -0
  6. data/LICENSE.md +27 -0
  7. data/README.md +33 -0
  8. data/Rakefile +50 -0
  9. data/doc_templates/LICENSE.md +27 -0
  10. data/doc_templates/README.md.erb +42 -0
  11. data/doc_templates/copyright_erb.txt +36 -0
  12. data/doc_templates/copyright_js.txt +4 -0
  13. data/doc_templates/copyright_ruby.txt +34 -0
  14. data/lib/files/.gitkeep +0 -0
  15. data/lib/measures/AddMonthlyJSONUtilityData/LICENSE.md +27 -0
  16. data/lib/measures/AddMonthlyJSONUtilityData/README.md +96 -0
  17. data/lib/measures/AddMonthlyJSONUtilityData/README.md.erb +42 -0
  18. data/lib/measures/AddMonthlyJSONUtilityData/measure.rb +280 -0
  19. data/lib/measures/AddMonthlyJSONUtilityData/measure.xml +163 -0
  20. data/lib/measures/AddMonthlyUtilityData/LICENSE.md +27 -0
  21. data/lib/measures/AddMonthlyUtilityData/README.md +64 -0
  22. data/lib/measures/AddMonthlyUtilityData/README.md.erb +42 -0
  23. data/lib/measures/AddMonthlyUtilityData/measure.rb +312 -0
  24. data/lib/measures/AddMonthlyUtilityData/measure.xml +115 -0
  25. data/lib/measures/AddMonthlyUtilityData/tests/AddMonthlyUtilityData_Test.rb +88 -0
  26. data/lib/measures/AddMonthlyUtilityData/tests/electric_billed_usages.json +198 -0
  27. data/lib/measures/AddMonthlyUtilityData/tests/gas_billed_usages.json +198 -0
  28. data/lib/measures/CalibrationReports/LICENSE.md +27 -0
  29. data/lib/measures/CalibrationReports/README.md +26 -0
  30. data/lib/measures/CalibrationReports/README.md.erb +42 -0
  31. data/lib/measures/CalibrationReports/measure.rb +511 -0
  32. data/lib/measures/CalibrationReports/measure.xml +98 -0
  33. data/lib/measures/CalibrationReports/resources/report.html.in +379 -0
  34. data/lib/measures/CalibrationReports/tests/CalibrationReports_Test.rb +523 -0
  35. data/lib/measures/CalibrationReports/tests/ExampleModel.osm +10497 -0
  36. data/lib/measures/CalibrationReports/tests/ExampleModelNoDemandInput.osm +10560 -0
  37. data/lib/measures/CalibrationReports/tests/ExampleModelNoGasInput.osm +10456 -0
  38. data/lib/measures/CalibrationReports/tests/USA_CO_Golden-NREL.724666_TMY3.epw +8768 -0
  39. data/lib/measures/CalibrationReportsEnhanced/LICENSE.md +27 -0
  40. data/lib/measures/CalibrationReportsEnhanced/README.md +143 -0
  41. data/lib/measures/CalibrationReportsEnhanced/README.md.erb +42 -0
  42. data/lib/measures/CalibrationReportsEnhanced/measure.rb +798 -0
  43. data/lib/measures/CalibrationReportsEnhanced/measure.xml +372 -0
  44. data/lib/measures/CalibrationReportsEnhanced/resources/report.html.in +380 -0
  45. data/lib/measures/CalibrationReportsEnhanced/tests/CalibrationReportsEnhanced_Test.rb +734 -0
  46. data/lib/measures/CalibrationReportsEnhanced/tests/ExampleModel.osm +10497 -0
  47. data/lib/measures/CalibrationReportsEnhanced/tests/ExampleModel_FuelOil.osm +12740 -0
  48. data/lib/measures/CalibrationReportsEnhanced/tests/USA_CO_Golden-NREL.724666_TMY3.epw +8768 -0
  49. data/lib/measures/CalibrationReportsEnhanced21/LICENSE.md +27 -0
  50. data/lib/measures/CalibrationReportsEnhanced21/README.md +109 -0
  51. data/lib/measures/CalibrationReportsEnhanced21/README.md.erb +42 -0
  52. data/lib/measures/CalibrationReportsEnhanced21/measure.rb +690 -0
  53. data/lib/measures/CalibrationReportsEnhanced21/measure.xml +269 -0
  54. data/lib/measures/CalibrationReportsEnhanced21/resources/report.html.in +380 -0
  55. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/LICENSE.md +27 -0
  56. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/README.md +48 -0
  57. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/README.md.erb +42 -0
  58. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/measure.rb +237 -0
  59. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/measure.xml +93 -0
  60. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/LICENSE.md +27 -0
  61. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/README.md +48 -0
  62. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/README.md.erb +42 -0
  63. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/measure.rb +228 -0
  64. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/measure.xml +93 -0
  65. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/LICENSE.md +27 -0
  66. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/README.md +64 -0
  67. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/README.md.erb +42 -0
  68. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/measure.rb +280 -0
  69. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/measure.xml +111 -0
  70. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/LICENSE.md +27 -0
  71. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/README.md +64 -0
  72. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/README.md.erb +42 -0
  73. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/measure.rb +270 -0
  74. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/measure.xml +111 -0
  75. data/lib/measures/CoilCoolingWaterMultiplier/LICENSE.md +27 -0
  76. data/lib/measures/CoilCoolingWaterMultiplier/README.md +80 -0
  77. data/lib/measures/CoilCoolingWaterMultiplier/README.md.erb +42 -0
  78. data/lib/measures/CoilCoolingWaterMultiplier/measure.rb +324 -0
  79. data/lib/measures/CoilCoolingWaterMultiplier/measure.xml +129 -0
  80. data/lib/measures/CoilCoolingWaterPercentChange/LICENSE.md +27 -0
  81. data/lib/measures/CoilCoolingWaterPercentChange/README.md +80 -0
  82. data/lib/measures/CoilCoolingWaterPercentChange/README.md.erb +42 -0
  83. data/lib/measures/CoilCoolingWaterPercentChange/measure.rb +311 -0
  84. data/lib/measures/CoilCoolingWaterPercentChange/measure.xml +129 -0
  85. data/lib/measures/CoilHeatingElectricMultiplier/LICENSE.md +27 -0
  86. data/lib/measures/CoilHeatingElectricMultiplier/README.md +48 -0
  87. data/lib/measures/CoilHeatingElectricMultiplier/README.md.erb +42 -0
  88. data/lib/measures/CoilHeatingElectricMultiplier/measure.rb +240 -0
  89. data/lib/measures/CoilHeatingElectricMultiplier/measure.xml +93 -0
  90. data/lib/measures/CoilHeatingElectricPercentChange/LICENSE.md +27 -0
  91. data/lib/measures/CoilHeatingElectricPercentChange/README.md +48 -0
  92. data/lib/measures/CoilHeatingElectricPercentChange/README.md.erb +42 -0
  93. data/lib/measures/CoilHeatingElectricPercentChange/measure.rb +231 -0
  94. data/lib/measures/CoilHeatingElectricPercentChange/measure.xml +93 -0
  95. data/lib/measures/CoilHeatingGasMultiplier/LICENSE.md +27 -0
  96. data/lib/measures/CoilHeatingGasMultiplier/README.md +64 -0
  97. data/lib/measures/CoilHeatingGasMultiplier/README.md.erb +42 -0
  98. data/lib/measures/CoilHeatingGasMultiplier/measure.rb +282 -0
  99. data/lib/measures/CoilHeatingGasMultiplier/measure.xml +111 -0
  100. data/lib/measures/CoilHeatingGasPercentChange/LICENSE.md +27 -0
  101. data/lib/measures/CoilHeatingGasPercentChange/README.md +64 -0
  102. data/lib/measures/CoilHeatingGasPercentChange/README.md.erb +42 -0
  103. data/lib/measures/CoilHeatingGasPercentChange/measure.rb +271 -0
  104. data/lib/measures/CoilHeatingGasPercentChange/measure.xml +111 -0
  105. data/lib/measures/CoilHeatingWaterMultiplier/LICENSE.md +27 -0
  106. data/lib/measures/CoilHeatingWaterMultiplier/README.md +48 -0
  107. data/lib/measures/CoilHeatingWaterMultiplier/README.md.erb +42 -0
  108. data/lib/measures/CoilHeatingWaterMultiplier/measure.rb +235 -0
  109. data/lib/measures/CoilHeatingWaterMultiplier/measure.xml +93 -0
  110. data/lib/measures/CoilHeatingWaterPercentChange/LICENSE.md +27 -0
  111. data/lib/measures/CoilHeatingWaterPercentChange/README.md +48 -0
  112. data/lib/measures/CoilHeatingWaterPercentChange/README.md.erb +42 -0
  113. data/lib/measures/CoilHeatingWaterPercentChange/measure.rb +226 -0
  114. data/lib/measures/CoilHeatingWaterPercentChange/measure.xml +93 -0
  115. data/lib/measures/ConstructionLayerZeroMaterialProperties/LICENSE.md +27 -0
  116. data/lib/measures/ConstructionLayerZeroMaterialProperties/README.md +88 -0
  117. data/lib/measures/ConstructionLayerZeroMaterialProperties/README.md.erb +42 -0
  118. data/lib/measures/ConstructionLayerZeroMaterialProperties/measure.rb +221 -0
  119. data/lib/measures/ConstructionLayerZeroMaterialProperties/measure.xml +194 -0
  120. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/LICENSE.md +27 -0
  121. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/README.md +40 -0
  122. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/README.md.erb +42 -0
  123. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/measure.rb +102 -0
  124. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/measure.xml +78 -0
  125. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/LICENSE.md +27 -0
  126. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/README.md +48 -0
  127. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/README.md.erb +42 -0
  128. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/measure.rb +263 -0
  129. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/measure.xml +97 -0
  130. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/LICENSE.md +27 -0
  131. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/README.md +48 -0
  132. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/README.md.erb +42 -0
  133. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/measure.rb +253 -0
  134. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/measure.xml +97 -0
  135. data/lib/measures/FansMultiplier/LICENSE.md +27 -0
  136. data/lib/measures/FansMultiplier/README.md +64 -0
  137. data/lib/measures/FansMultiplier/README.md.erb +42 -0
  138. data/lib/measures/FansMultiplier/measure.rb +297 -0
  139. data/lib/measures/FansMultiplier/measure.xml +166 -0
  140. data/lib/measures/FansPercentChange/LICENSE.md +27 -0
  141. data/lib/measures/FansPercentChange/README.md +64 -0
  142. data/lib/measures/FansPercentChange/README.md.erb +42 -0
  143. data/lib/measures/FansPercentChange/measure.rb +286 -0
  144. data/lib/measures/FansPercentChange/measure.xml +166 -0
  145. data/lib/measures/GeneralCalibrationMeasureMultiplier/LICENSE.md +27 -0
  146. data/lib/measures/GeneralCalibrationMeasureMultiplier/README.md +112 -0
  147. data/lib/measures/GeneralCalibrationMeasureMultiplier/README.md.erb +42 -0
  148. data/lib/measures/GeneralCalibrationMeasureMultiplier/measure.rb +639 -0
  149. data/lib/measures/GeneralCalibrationMeasureMultiplier/measure.xml +229 -0
  150. data/lib/measures/GeneralCalibrationMeasurePercentChange/LICENSE.md +27 -0
  151. data/lib/measures/GeneralCalibrationMeasurePercentChange/README.md +112 -0
  152. data/lib/measures/GeneralCalibrationMeasurePercentChange/README.md.erb +42 -0
  153. data/lib/measures/GeneralCalibrationMeasurePercentChange/measure.rb +756 -0
  154. data/lib/measures/GeneralCalibrationMeasurePercentChange/measure.xml +229 -0
  155. data/lib/measures/HardSizeHvac/LICENSE.md +27 -0
  156. data/lib/measures/HardSizeHvac/README.md +26 -0
  157. data/lib/measures/HardSizeHvac/README.md.erb +42 -0
  158. data/lib/measures/HardSizeHvac/measure.rb +88 -0
  159. data/lib/measures/HardSizeHvac/measure.xml +81 -0
  160. data/lib/measures/MaalkaMonthlyJSONUtilityData/LICENSE.md +27 -0
  161. data/lib/measures/MaalkaMonthlyJSONUtilityData/README.md +104 -0
  162. data/lib/measures/MaalkaMonthlyJSONUtilityData/README.md.erb +42 -0
  163. data/lib/measures/MaalkaMonthlyJSONUtilityData/measure.rb +304 -0
  164. data/lib/measures/MaalkaMonthlyJSONUtilityData/measure.xml +216 -0
  165. data/lib/measures/RValueOfInsulationForConstructionMultiplier/LICENSE.md +27 -0
  166. data/lib/measures/RValueOfInsulationForConstructionMultiplier/README.md +40 -0
  167. data/lib/measures/RValueOfInsulationForConstructionMultiplier/README.md.erb +42 -0
  168. data/lib/measures/RValueOfInsulationForConstructionMultiplier/measure.rb +196 -0
  169. data/lib/measures/RValueOfInsulationForConstructionMultiplier/measure.xml +132 -0
  170. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/LICENSE.md +27 -0
  171. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/README.md +40 -0
  172. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/README.md.erb +42 -0
  173. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/measure.rb +189 -0
  174. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/measure.xml +132 -0
  175. data/lib/measures/RoofThermalPropertiesMultiplier/LICENSE.md +27 -0
  176. data/lib/measures/RoofThermalPropertiesMultiplier/README.md +48 -0
  177. data/lib/measures/RoofThermalPropertiesMultiplier/README.md.erb +42 -0
  178. data/lib/measures/RoofThermalPropertiesMultiplier/measure.rb +263 -0
  179. data/lib/measures/RoofThermalPropertiesMultiplier/measure.xml +97 -0
  180. data/lib/measures/RoofThermalPropertiesPercentChange/LICENSE.md +27 -0
  181. data/lib/measures/RoofThermalPropertiesPercentChange/README.md +48 -0
  182. data/lib/measures/RoofThermalPropertiesPercentChange/README.md.erb +42 -0
  183. data/lib/measures/RoofThermalPropertiesPercentChange/measure.rb +253 -0
  184. data/lib/measures/RoofThermalPropertiesPercentChange/measure.xml +97 -0
  185. data/lib/measures/TimeseriesObjectiveFunction/LICENSE.md +27 -0
  186. data/lib/measures/TimeseriesObjectiveFunction/README.md +207 -0
  187. data/lib/measures/TimeseriesObjectiveFunction/README.md.erb +42 -0
  188. data/lib/measures/TimeseriesObjectiveFunction/measure.rb +748 -0
  189. data/lib/measures/TimeseriesObjectiveFunction/measure.xml +435 -0
  190. data/lib/measures/TimeseriesObjectiveFunction/resources/report.html.erb +288 -0
  191. data/lib/measures/TimeseriesPlot/LICENSE.md +27 -0
  192. data/lib/measures/TimeseriesPlot/README.md +56 -0
  193. data/lib/measures/TimeseriesPlot/README.md.erb +42 -0
  194. data/lib/measures/TimeseriesPlot/measure.rb +302 -0
  195. data/lib/measures/TimeseriesPlot/measure.xml +137 -0
  196. data/lib/measures/TimeseriesPlot/resources/report.html.erb +270 -0
  197. data/lib/measures/WaterHeaterMixedMultiplier/LICENSE.md +27 -0
  198. data/lib/measures/WaterHeaterMixedMultiplier/README.md +64 -0
  199. data/lib/measures/WaterHeaterMixedMultiplier/README.md.erb +42 -0
  200. data/lib/measures/WaterHeaterMixedMultiplier/measure.rb +255 -0
  201. data/lib/measures/WaterHeaterMixedMultiplier/measure.xml +180 -0
  202. data/lib/measures/WaterHeaterMixedPercentChange/LICENSE.md +27 -0
  203. data/lib/measures/WaterHeaterMixedPercentChange/README.md +64 -0
  204. data/lib/measures/WaterHeaterMixedPercentChange/README.md.erb +42 -0
  205. data/lib/measures/WaterHeaterMixedPercentChange/measure.rb +245 -0
  206. data/lib/measures/WaterHeaterMixedPercentChange/measure.xml +180 -0
  207. data/lib/measures/zone_report/LICENSE.md +27 -0
  208. data/lib/measures/zone_report/README.md +26 -0
  209. data/lib/measures/zone_report/README.md.erb +42 -0
  210. data/lib/measures/zone_report/measure.rb +706 -0
  211. data/lib/measures/zone_report/measure.xml +67 -0
  212. data/lib/measures/zone_report/resources/report.html.in +342 -0
  213. data/lib/openstudio-calibration-measures.rb +36 -0
  214. data/lib/openstudio/calibration_measures.rb +37 -0
  215. data/lib/openstudio/calibration_measures/extension.rb +49 -0
  216. data/lib/openstudio/calibration_measures/version.rb +40 -0
  217. data/openstudio-calibration.gemspec +30 -0
  218. metadata +331 -0
@@ -0,0 +1,166 @@
1
+ <measure>
2
+ <schema_version>3.0</schema_version>
3
+ <name>fans_multiplier</name>
4
+ <uid>af156383-cfe2-4798-b581-08a4cccb8877</uid>
5
+ <version_id>4fb32abb-5e11-479a-ba02-c2809774c9ce</version_id>
6
+ <version_modified>20200325T030943Z</version_modified>
7
+ <xml_checksum>3C1DA54F</xml_checksum>
8
+ <class_name>FansMultiplier</class_name>
9
+ <display_name>Fans Multiplier</display_name>
10
+ <description>This is a general purpose measure to calibrate Fans with a Multiplier.</description>
11
+ <modeler_description>It will be used for calibration maximum flow rate, efficiency, pressure rise and motor efficiency. User can choose between a SINGLE Fan or ALL the Fans.</modeler_description>
12
+ <arguments>
13
+ <argument>
14
+ <name>fan</name>
15
+ <display_name>Apply the Measure to a SINGLE Fan, ALL the Fans or NONE.</display_name>
16
+ <type>Choice</type>
17
+ <required>true</required>
18
+ <model_dependent>false</model_dependent>
19
+ <default_value>*All Fans*</default_value>
20
+ <choices>
21
+ <choice>
22
+ <value>{849f9542-7baa-4ad1-bf2b-a446311c32cc}</value>
23
+ <display_name>*All Fans*</display_name>
24
+ </choice>
25
+ <choice>
26
+ <value>0</value>
27
+ <display_name>*None*</display_name>
28
+ </choice>
29
+ </choices>
30
+ </argument>
31
+ <argument>
32
+ <name>max_flowrate_multiplier</name>
33
+ <display_name>Multiplier for Maximum FlowRate.</display_name>
34
+ <description>Multiplier for Maximum FlowRate.</description>
35
+ <type>Double</type>
36
+ <required>true</required>
37
+ <model_dependent>false</model_dependent>
38
+ <default_value>1</default_value>
39
+ </argument>
40
+ <argument>
41
+ <name>fan_efficiency_multiplier</name>
42
+ <display_name>Multiplier for Fan Efficiency.</display_name>
43
+ <description>Multiplier for Fan Efficiency.</description>
44
+ <type>Double</type>
45
+ <required>true</required>
46
+ <model_dependent>false</model_dependent>
47
+ <default_value>1</default_value>
48
+ </argument>
49
+ <argument>
50
+ <name>pressure_rise_multiplier</name>
51
+ <display_name>Multiplier for Pressure Rise.</display_name>
52
+ <description>Multiplier for Pressure Rise.</description>
53
+ <type>Double</type>
54
+ <required>true</required>
55
+ <model_dependent>false</model_dependent>
56
+ <default_value>1</default_value>
57
+ </argument>
58
+ <argument>
59
+ <name>motor_efficiency_multiplier</name>
60
+ <display_name>Multiplier for Motor Efficiency.</display_name>
61
+ <description>Multiplier for Motor Efficiency.</description>
62
+ <type>Double</type>
63
+ <required>true</required>
64
+ <model_dependent>false</model_dependent>
65
+ <default_value>1</default_value>
66
+ </argument>
67
+ </arguments>
68
+ <outputs/>
69
+ <provenances/>
70
+ <tags>
71
+ <tag>HVAC.Whole System</tag>
72
+ </tags>
73
+ <attributes>
74
+ <attribute>
75
+ <name>Intended Software Tool</name>
76
+ <value>Analysis Spreadsheet</value>
77
+ <datatype>string</datatype>
78
+ </attribute>
79
+ <attribute>
80
+ <name>Intended Use Case</name>
81
+ <value>Model Articulation</value>
82
+ <datatype>string</datatype>
83
+ </attribute>
84
+ <attribute>
85
+ <name>Intended Use Case</name>
86
+ <value>Calibration</value>
87
+ <datatype>string</datatype>
88
+ </attribute>
89
+ <attribute>
90
+ <name>Intended Use Case</name>
91
+ <value>Sensitivity Analysis</value>
92
+ <datatype>string</datatype>
93
+ </attribute>
94
+ <attribute>
95
+ <name>Measure Type</name>
96
+ <value>ModelMeasure</value>
97
+ <datatype>string</datatype>
98
+ </attribute>
99
+ <attribute>
100
+ <name>Intended Software Tool</name>
101
+ <value>Apply Measure Now</value>
102
+ <datatype>string</datatype>
103
+ </attribute>
104
+ <attribute>
105
+ <name>Intended Software Tool</name>
106
+ <value>OpenStudio Application</value>
107
+ <datatype>string</datatype>
108
+ </attribute>
109
+ <attribute>
110
+ <name>Intended Software Tool</name>
111
+ <value>Parametric Analysis Tool</value>
112
+ <datatype>string</datatype>
113
+ </attribute>
114
+ <attribute>
115
+ <name>Intended Software Tool</name>
116
+ <value>Analysis Spreadsheet</value>
117
+ <datatype>string</datatype>
118
+ </attribute>
119
+ <attribute>
120
+ <name>Intended Use Case</name>
121
+ <value>Model Articulation</value>
122
+ <datatype>string</datatype>
123
+ </attribute>
124
+ <attribute>
125
+ <name>Intended Use Case</name>
126
+ <value>Calibration</value>
127
+ <datatype>string</datatype>
128
+ </attribute>
129
+ <attribute>
130
+ <name>Intended Use Case</name>
131
+ <value>Sensitivity Analysis</value>
132
+ <datatype>string</datatype>
133
+ </attribute>
134
+ </attributes>
135
+ <files>
136
+ <file>
137
+ <filename>LICENSE.md</filename>
138
+ <filetype>md</filetype>
139
+ <usage_type>license</usage_type>
140
+ <checksum>E0468DD6</checksum>
141
+ </file>
142
+ <file>
143
+ <filename>README.md.erb</filename>
144
+ <filetype>erb</filetype>
145
+ <usage_type>readmeerb</usage_type>
146
+ <checksum>703C9964</checksum>
147
+ </file>
148
+ <file>
149
+ <filename>README.md</filename>
150
+ <filetype>md</filetype>
151
+ <usage_type>readme</usage_type>
152
+ <checksum>E54F87D8</checksum>
153
+ </file>
154
+ <file>
155
+ <version>
156
+ <software_program>OpenStudio</software_program>
157
+ <identifier>2.1.0</identifier>
158
+ <min_compatible>2.1.0</min_compatible>
159
+ </version>
160
+ <filename>measure.rb</filename>
161
+ <filetype>rb</filetype>
162
+ <usage_type>script</usage_type>
163
+ <checksum>81E35908</checksum>
164
+ </file>
165
+ </files>
166
+ </measure>
@@ -0,0 +1,27 @@
1
+ OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC. All rights reserved.
2
+
3
+ Redistribution and use in source and binary forms, with or without modification, are permitted
4
+ provided that the following conditions are met:
5
+
6
+ (1) Redistributions of source code must retain the above copyright notice, this list of conditions
7
+ and the following disclaimer.
8
+
9
+ (2) Redistributions in binary form must reproduce the above copyright notice, this list of conditions
10
+ and the following disclaimer in the documentation and/or other materials provided with the distribution.
11
+
12
+ (3) Neither the name of the copyright holder nor the names of any contributors may be used to endorse
13
+ or promote products derived from this software without specific prior written permission from the
14
+ respective party.
15
+
16
+ (4) Other than as required in clauses (1) and (2), distributions in any form of modifications or other
17
+ derivative works may not use the "OpenStudio" trademark, "OS", "os", or any other confusingly similar
18
+ designation without specific prior written permission from Alliance for Sustainable Energy, LLC.
19
+
20
+ THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED
21
+ WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
22
+ PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER, THE UNITED STATES GOVERNMENT,
23
+ OR ANY CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
24
+ DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,
25
+ OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
26
+ STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
27
+ SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
@@ -0,0 +1,64 @@
1
+
2
+
3
+ ###### (Automatically generated documentation)
4
+
5
+ # Fans Percent Change
6
+
7
+ ## Description
8
+ This is a general purpose measure to calibrate Fans with a Percent Change.
9
+
10
+ ## Modeler Description
11
+ It will be used for calibration maximum flow rate, efficiency, pressure rise and motor efficiency. User can choose between a SINGLE Fan or ALL the Fans.
12
+
13
+ ## Measure Type
14
+ ModelMeasure
15
+
16
+ ## Taxonomy
17
+
18
+
19
+ ## Arguments
20
+
21
+
22
+ ### Apply the Measure to a SINGLE Fan, ALL the Fans or NONE.
23
+
24
+ **Name:** fan,
25
+ **Type:** Choice,
26
+ **Units:** ,
27
+ **Required:** true,
28
+ **Model Dependent:** false
29
+
30
+ ### Percent Change for Maximum FlowRate.
31
+ Percent Change for Maximum FlowRate.
32
+ **Name:** max_flowrate_perc_change,
33
+ **Type:** Double,
34
+ **Units:** ,
35
+ **Required:** true,
36
+ **Model Dependent:** false
37
+
38
+ ### Percent Change for Fan Efficiency.
39
+ Percent Change for Fan Efficiency.
40
+ **Name:** fan_efficiency_perc_change,
41
+ **Type:** Double,
42
+ **Units:** ,
43
+ **Required:** true,
44
+ **Model Dependent:** false
45
+
46
+ ### Percent Change for Pressure Rise.
47
+ Percent Change for Pressure Rise.
48
+ **Name:** pressure_rise_perc_change,
49
+ **Type:** Double,
50
+ **Units:** ,
51
+ **Required:** true,
52
+ **Model Dependent:** false
53
+
54
+ ### Percent Change for Motor Efficiency.
55
+ Percent Change for Motor Efficiency.
56
+ **Name:** motor_efficiency_perc_change,
57
+ **Type:** Double,
58
+ **Units:** ,
59
+ **Required:** true,
60
+ **Model Dependent:** false
61
+
62
+
63
+
64
+
@@ -0,0 +1,42 @@
1
+ <%#= README.md.erb is used to auto-generate README.md. %>
2
+ <%#= To manually maintain README.md throw away README.md.erb and manually edit README.md %>
3
+ ###### (Automatically generated documentation)
4
+
5
+ # <%= name %>
6
+
7
+ ## Description
8
+ <%= description %>
9
+
10
+ ## Modeler Description
11
+ <%= modelerDescription %>
12
+
13
+ ## Measure Type
14
+ <%= measureType %>
15
+
16
+ ## Taxonomy
17
+ <%= taxonomy %>
18
+
19
+ ## Arguments
20
+
21
+ <% arguments.each do |argument| %>
22
+ ### <%= argument[:display_name] %>
23
+ <%= argument[:description] %>
24
+ **Name:** <%= argument[:name] %>,
25
+ **Type:** <%= argument[:type] %>,
26
+ **Units:** <%= argument[:units] %>,
27
+ **Required:** <%= argument[:required] %>,
28
+ **Model Dependent:** <%= argument[:model_dependent] %>
29
+ <% end %>
30
+
31
+ <% if arguments.size == 0 %>
32
+ <%= "This measure does not have any user arguments" %>
33
+ <% end %>
34
+
35
+ <% if outputs.size > 0 %>
36
+ ## Outputs
37
+ <% output_names = [] %>
38
+ <% outputs.each do |output| %>
39
+ <% output_names << output[:display_name] %>
40
+ <% end %>
41
+ <%= output_names.join(", ") %>
42
+ <% end %>
@@ -0,0 +1,286 @@
1
+ # *******************************************************************************
2
+ # OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC.
3
+ # All rights reserved.
4
+ # Redistribution and use in source and binary forms, with or without
5
+ # modification, are permitted provided that the following conditions are met:
6
+ #
7
+ # (1) Redistributions of source code must retain the above copyright notice,
8
+ # this list of conditions and the following disclaimer.
9
+ #
10
+ # (2) Redistributions in binary form must reproduce the above copyright notice,
11
+ # this list of conditions and the following disclaimer in the documentation
12
+ # and/or other materials provided with the distribution.
13
+ #
14
+ # (3) Neither the name of the copyright holder nor the names of any contributors
15
+ # may be used to endorse or promote products derived from this software without
16
+ # specific prior written permission from the respective party.
17
+ #
18
+ # (4) Other than as required in clauses (1) and (2), distributions in any form
19
+ # of modifications or other derivative works may not use the "OpenStudio"
20
+ # trademark, "OS", "os", or any other confusingly similar designation without
21
+ # specific prior written permission from Alliance for Sustainable Energy, LLC.
22
+ #
23
+ # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS
24
+ # "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
25
+ # THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
26
+ # ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE
27
+ # UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF
28
+ # THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
29
+ # EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT
30
+ # OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
31
+ # INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
32
+ # STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
33
+ # OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
34
+ # *******************************************************************************
35
+
36
+ # start the measure
37
+ class FansPercentChange < OpenStudio::Measure::ModelMeasure
38
+ # human readable name
39
+ def name
40
+ 'Fans Percent Change'
41
+ end
42
+
43
+ # human readable description
44
+ def description
45
+ 'This is a general purpose measure to calibrate Fans with a Percent Change.'
46
+ end
47
+
48
+ # human readable description of modeling approach
49
+ def modeler_description
50
+ 'It will be used for calibration maximum flow rate, efficiency, pressure rise and motor efficiency. User can choose between a SINGLE Fan or ALL the Fans.'
51
+ end
52
+
53
+ def change_name(object, max_flowrate_perc_change, fan_efficiency_perc_change, pressure_rise_perc_change, motor_efficiency_perc_change)
54
+ nameString = object.name.get.to_s
55
+ if max_flowrate_perc_change != 0.0
56
+ nameString += " #{max_flowrate_perc_change.round(2)}percng flow"
57
+ end
58
+ if pressure_rise_perc_change != 0.0
59
+ nameString += " #{pressure_rise_perc_change.round(2)}percng press"
60
+ end
61
+ if fan_efficiency_perc_change != 0.0
62
+ nameString += " #{fan_efficiency_perc_change.round(2)}percng fanEff"
63
+ end
64
+ if motor_efficiency_perc_change != 0.0
65
+ nameString += " #{motor_efficiency_perc_change.round(2)}percng motorEff"
66
+ end
67
+ object.setName(nameString)
68
+ end
69
+
70
+ # define the arguments that the user will input
71
+ def arguments(model)
72
+ args = OpenStudio::Measure::OSArgumentVector.new
73
+
74
+ # populate choice argument for constructions that are applied to surfaces in the model
75
+ loop_handles = OpenStudio::StringVector.new
76
+ loop_display_names = OpenStudio::StringVector.new
77
+
78
+ # putting air loops and names into hash
79
+ loop_args = model.getAirLoopHVACs
80
+ loop_args_hash = {}
81
+ loop_args.each do |loop_arg|
82
+ loop_args_hash[loop_arg.name.to_s] = loop_arg
83
+ end
84
+
85
+ # looping through sorted hash of air loops
86
+ loop_args_hash.sort.map do |_key, value|
87
+ show_loop = false
88
+ components = value.supplyComponents
89
+ components.each do |component|
90
+ unless component.to_FanConstantVolume.empty?
91
+ show_loop = true
92
+ loop_handles << component.handle.to_s
93
+ loop_display_names << component.name.to_s
94
+ end
95
+ unless component.to_FanVariableVolume.empty?
96
+ show_loop = true
97
+ loop_handles << component.handle.to_s
98
+ loop_display_names << component.name.to_s
99
+ end
100
+ next if component.to_FanOnOff.empty?
101
+ show_loop = true
102
+ loop_handles << component.handle.to_s
103
+ loop_display_names << component.name.to_s
104
+ end
105
+
106
+ # if loop as object of correct type then add to hash.
107
+ # if show_loop == true
108
+ # loop_handles << value.handle.to_s
109
+ # loop_display_names << key
110
+ # end
111
+ end
112
+
113
+ # add building to string vector with space type
114
+ building = model.getBuilding
115
+ loop_handles << building.handle.to_s
116
+ loop_display_names << '*All Fans*'
117
+ loop_handles << '0'
118
+ loop_display_names << '*None*'
119
+
120
+ # make a choice argument for space type
121
+ fan_arg = OpenStudio::Measure::OSArgument.makeChoiceArgument('fan', loop_handles, loop_display_names)
122
+ fan_arg.setDisplayName('Apply the Measure to a SINGLE Fan, ALL the Fans or NONE.')
123
+ fan_arg.setDefaultValue('*All Fans*') # if no space type is chosen this will run on the entire building
124
+ args << fan_arg
125
+
126
+ # max_flowrate_perc_change
127
+ max_flowrate_perc_change = OpenStudio::Measure::OSArgument.makeDoubleArgument('max_flowrate_perc_change', true)
128
+ max_flowrate_perc_change.setDisplayName('Percent Change for Maximum FlowRate.')
129
+ max_flowrate_perc_change.setDescription('Percent Change for Maximum FlowRate.')
130
+ max_flowrate_perc_change.setDefaultValue(0.0)
131
+ max_flowrate_perc_change.setMinValue(0.0)
132
+ args << max_flowrate_perc_change
133
+
134
+ # fan_efficiency_perc_change
135
+ fan_efficiency_perc_change = OpenStudio::Measure::OSArgument.makeDoubleArgument('fan_efficiency_perc_change', true)
136
+ fan_efficiency_perc_change.setDisplayName('Percent Change for Fan Efficiency.')
137
+ fan_efficiency_perc_change.setDescription('Percent Change for Fan Efficiency.')
138
+ fan_efficiency_perc_change.setDefaultValue(0.0)
139
+ args << fan_efficiency_perc_change
140
+
141
+ # pressure_rise_perc_change
142
+ pressure_rise_perc_change = OpenStudio::Measure::OSArgument.makeDoubleArgument('pressure_rise_perc_change', true)
143
+ pressure_rise_perc_change.setDisplayName('Percent Change for Pressure Rise.')
144
+ pressure_rise_perc_change.setDescription('Percent Change for Pressure Rise.')
145
+ pressure_rise_perc_change.setDefaultValue(0.0)
146
+ args << pressure_rise_perc_change
147
+
148
+ # motor_efficiency_perc_change
149
+ motor_efficiency_perc_change = OpenStudio::Measure::OSArgument.makeDoubleArgument('motor_efficiency_perc_change', true)
150
+ motor_efficiency_perc_change.setDisplayName('Percent Change for Motor Efficiency.')
151
+ motor_efficiency_perc_change.setDescription('Percent Change for Motor Efficiency.')
152
+ motor_efficiency_perc_change.setDefaultValue(0.0)
153
+ args << motor_efficiency_perc_change
154
+
155
+ args
156
+ end
157
+
158
+ # define what happens when the measure is run
159
+ def run(model, runner, user_arguments)
160
+ super(model, runner, user_arguments)
161
+
162
+ # use the built-in error checking
163
+ unless runner.validateUserArguments(arguments(model), user_arguments)
164
+ return false
165
+ end
166
+
167
+ # assign the user inputs to variables
168
+ fan_object = runner.getOptionalWorkspaceObjectChoiceValue('fan', user_arguments, model)
169
+ fan_handle = runner.getStringArgumentValue('fan', user_arguments)
170
+ pressure_rise_perc_change = runner.getDoubleArgumentValue('pressure_rise_perc_change', user_arguments)
171
+ motor_efficiency_perc_change = runner.getDoubleArgumentValue('motor_efficiency_perc_change', user_arguments)
172
+ max_flowrate_perc_change = runner.getDoubleArgumentValue('max_flowrate_perc_change', user_arguments)
173
+ fan_efficiency_perc_change = runner.getDoubleArgumentValue('fan_efficiency_perc_change', user_arguments)
174
+
175
+ # find objects to change
176
+ fans = []
177
+ building = model.getBuilding
178
+ building_handle = building.handle.to_s
179
+ runner.registerInfo("fan_handle: #{fan_handle}")
180
+ # setup fans
181
+ if fan_handle == building_handle
182
+ # Use ALL Fans
183
+ runner.registerInfo('Applying change to ALL Fans')
184
+ loops = model.getAirLoopHVACs
185
+ # loop through air loops
186
+ loops.each do |loop|
187
+ supply_components = loop.supplyComponents
188
+ # find fans on loops
189
+ supply_components.each do |supply_component|
190
+ if !supply_component.to_FanConstantVolume.empty?
191
+ fans << supply_component.to_FanConstantVolume.get
192
+ elsif !supply_component.to_FanVariableVolume.empty?
193
+ fans << supply_component.to_FanVariableVolume.get
194
+ elsif !supply_component.to_FanOnOff.empty?
195
+ fans << supply_component.to_FanOnOff.get
196
+ end
197
+ end
198
+ end
199
+ elsif fan_handle == 0.to_s
200
+ # Fans set to NONE so do nothing
201
+ runner.registerInfo('Applying change to NONE Fans')
202
+ elsif !fan_handle.empty?
203
+ # Single Fan handle found, check if object is good
204
+ if !fan_object.get.to_FanConstantVolume.empty?
205
+ runner.registerInfo("Applying change to #{fan_object.get.name} Fan")
206
+ fans << fan_object.get.to_FanConstantVolume.get
207
+ elsif !fan_object.get.to_FanVariableVolume.empty?
208
+ runner.registerInfo("Applying change to #{fan_object.get.name} Fan")
209
+ fans << fan_object.get.to_FanVariableVolume.get
210
+ elsif !fan_object.get.to_FanOnOff.empty?
211
+ runner.registerInfo("Applying change to #{fan_object.get.name} Fan")
212
+ fans << fan_object.get.to_FanOnOff.get
213
+ else
214
+ runner.registerError("Fan with handle #{fan_handle} could not be found.")
215
+ end
216
+ else
217
+ runner.registerError('Fan handle is empty.')
218
+ return false
219
+ end
220
+
221
+ # report initial condition of model
222
+ runner.registerInitialCondition("Fans to change: #{fans.size}")
223
+ runner.registerInfo("Fans to change: #{fans.size}")
224
+ altered_fans = []
225
+ altered_maxflow = []
226
+ altered_pressurerise = []
227
+ altered_fanefficiency = []
228
+ altered_motorefficiency = []
229
+ # loop through fans
230
+ fans.each do |fan|
231
+ altered_fan = false
232
+ # modify max flowrate
233
+ if max_flowrate_perc_change != 0.0
234
+ if fan.maximumFlowRate.is_initialized
235
+ runner.registerInfo("Applying #{max_flowrate_perc_change} Percent Change to #{fan.name.get}.")
236
+ fan.setMaximumFlowRate(fan.maximumFlowRate + fan.maximumFlowRate * max_flowrate_perc_change * 0.01)
237
+ altered_maxflow << fan.handle.to_s
238
+ altered_fan = true
239
+ end
240
+ end
241
+
242
+ # modify fan_efficiency_perc_change
243
+ if fan_efficiency_perc_change != 0.0
244
+ runner.registerInfo("Applying #{fan_efficiency_perc_change} Percent Change to #{fan.name.get}.")
245
+ fan.setFanEfficiency(fan.fanEfficiency + fan.fanEfficiency * fan_efficiency_perc_change * 0.01)
246
+ altered_fanefficiency << fan.handle.to_s
247
+ altered_fan = true
248
+ end
249
+
250
+ # pressure_rise_perc_change
251
+ if pressure_rise_perc_change != 0.0
252
+ runner.registerInfo("Applying #{pressure_rise_perc_change} Percent Change to #{fan.name.get}.")
253
+ fan.setPressureRise(fan.pressureRise + fan.pressureRise * pressure_rise_perc_change * 0.01)
254
+ altered_pressurerise << fan.handle.to_s
255
+ altered_fan = true
256
+ end
257
+
258
+ # motor_efficiency_perc_change
259
+ if motor_efficiency_perc_change != 0.0
260
+ runner.registerInfo("Applying #{motor_efficiency_perc_change} Percent Change to #{fan.name.get}.")
261
+ fan.setMotorEfficiency(fan.motorEfficiency + fan.motorEfficiency * motor_efficiency_perc_change * 0.01)
262
+ altered_motorefficiency << fan.handle.to_s
263
+ altered_fan = true
264
+ end
265
+
266
+ next unless altered_fan
267
+ altered_fans << fan.handle.to_s
268
+ change_name(fan, max_flowrate_perc_change, fan_efficiency_perc_change, pressure_rise_perc_change, motor_efficiency_perc_change)
269
+ runner.registerInfo("Fan name changed to: #{fan.name.get}")
270
+ end # end fan loop
271
+
272
+ # na if nothing in model to look at
273
+ if altered_fans.empty?
274
+ runner.registerAsNotApplicable('No Fans were altered in the model')
275
+ return true
276
+ end
277
+
278
+ # report final condition of model
279
+ runner.registerFinalCondition("#{altered_fans.size} fans objects were altered.")
280
+
281
+ true
282
+ end
283
+ end
284
+
285
+ # register the measure to be used by the application
286
+ FansPercentChange.new.registerWithApplication