openstudio-calibration 0.1.2

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (218) hide show
  1. checksums.yaml +7 -0
  2. data/.gitignore +29 -0
  3. data/CHANGELOG.md +14 -0
  4. data/Gemfile +20 -0
  5. data/Jenkinsfile +6 -0
  6. data/LICENSE.md +27 -0
  7. data/README.md +33 -0
  8. data/Rakefile +50 -0
  9. data/doc_templates/LICENSE.md +27 -0
  10. data/doc_templates/README.md.erb +42 -0
  11. data/doc_templates/copyright_erb.txt +36 -0
  12. data/doc_templates/copyright_js.txt +4 -0
  13. data/doc_templates/copyright_ruby.txt +34 -0
  14. data/lib/files/.gitkeep +0 -0
  15. data/lib/measures/AddMonthlyJSONUtilityData/LICENSE.md +27 -0
  16. data/lib/measures/AddMonthlyJSONUtilityData/README.md +96 -0
  17. data/lib/measures/AddMonthlyJSONUtilityData/README.md.erb +42 -0
  18. data/lib/measures/AddMonthlyJSONUtilityData/measure.rb +280 -0
  19. data/lib/measures/AddMonthlyJSONUtilityData/measure.xml +163 -0
  20. data/lib/measures/AddMonthlyUtilityData/LICENSE.md +27 -0
  21. data/lib/measures/AddMonthlyUtilityData/README.md +64 -0
  22. data/lib/measures/AddMonthlyUtilityData/README.md.erb +42 -0
  23. data/lib/measures/AddMonthlyUtilityData/measure.rb +312 -0
  24. data/lib/measures/AddMonthlyUtilityData/measure.xml +115 -0
  25. data/lib/measures/AddMonthlyUtilityData/tests/AddMonthlyUtilityData_Test.rb +88 -0
  26. data/lib/measures/AddMonthlyUtilityData/tests/electric_billed_usages.json +198 -0
  27. data/lib/measures/AddMonthlyUtilityData/tests/gas_billed_usages.json +198 -0
  28. data/lib/measures/CalibrationReports/LICENSE.md +27 -0
  29. data/lib/measures/CalibrationReports/README.md +26 -0
  30. data/lib/measures/CalibrationReports/README.md.erb +42 -0
  31. data/lib/measures/CalibrationReports/measure.rb +511 -0
  32. data/lib/measures/CalibrationReports/measure.xml +98 -0
  33. data/lib/measures/CalibrationReports/resources/report.html.in +379 -0
  34. data/lib/measures/CalibrationReports/tests/CalibrationReports_Test.rb +523 -0
  35. data/lib/measures/CalibrationReports/tests/ExampleModel.osm +10497 -0
  36. data/lib/measures/CalibrationReports/tests/ExampleModelNoDemandInput.osm +10560 -0
  37. data/lib/measures/CalibrationReports/tests/ExampleModelNoGasInput.osm +10456 -0
  38. data/lib/measures/CalibrationReports/tests/USA_CO_Golden-NREL.724666_TMY3.epw +8768 -0
  39. data/lib/measures/CalibrationReportsEnhanced/LICENSE.md +27 -0
  40. data/lib/measures/CalibrationReportsEnhanced/README.md +143 -0
  41. data/lib/measures/CalibrationReportsEnhanced/README.md.erb +42 -0
  42. data/lib/measures/CalibrationReportsEnhanced/measure.rb +798 -0
  43. data/lib/measures/CalibrationReportsEnhanced/measure.xml +372 -0
  44. data/lib/measures/CalibrationReportsEnhanced/resources/report.html.in +380 -0
  45. data/lib/measures/CalibrationReportsEnhanced/tests/CalibrationReportsEnhanced_Test.rb +734 -0
  46. data/lib/measures/CalibrationReportsEnhanced/tests/ExampleModel.osm +10497 -0
  47. data/lib/measures/CalibrationReportsEnhanced/tests/ExampleModel_FuelOil.osm +12740 -0
  48. data/lib/measures/CalibrationReportsEnhanced/tests/USA_CO_Golden-NREL.724666_TMY3.epw +8768 -0
  49. data/lib/measures/CalibrationReportsEnhanced21/LICENSE.md +27 -0
  50. data/lib/measures/CalibrationReportsEnhanced21/README.md +109 -0
  51. data/lib/measures/CalibrationReportsEnhanced21/README.md.erb +42 -0
  52. data/lib/measures/CalibrationReportsEnhanced21/measure.rb +690 -0
  53. data/lib/measures/CalibrationReportsEnhanced21/measure.xml +269 -0
  54. data/lib/measures/CalibrationReportsEnhanced21/resources/report.html.in +380 -0
  55. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/LICENSE.md +27 -0
  56. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/README.md +48 -0
  57. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/README.md.erb +42 -0
  58. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/measure.rb +237 -0
  59. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/measure.xml +93 -0
  60. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/LICENSE.md +27 -0
  61. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/README.md +48 -0
  62. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/README.md.erb +42 -0
  63. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/measure.rb +228 -0
  64. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/measure.xml +93 -0
  65. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/LICENSE.md +27 -0
  66. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/README.md +64 -0
  67. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/README.md.erb +42 -0
  68. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/measure.rb +280 -0
  69. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/measure.xml +111 -0
  70. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/LICENSE.md +27 -0
  71. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/README.md +64 -0
  72. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/README.md.erb +42 -0
  73. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/measure.rb +270 -0
  74. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/measure.xml +111 -0
  75. data/lib/measures/CoilCoolingWaterMultiplier/LICENSE.md +27 -0
  76. data/lib/measures/CoilCoolingWaterMultiplier/README.md +80 -0
  77. data/lib/measures/CoilCoolingWaterMultiplier/README.md.erb +42 -0
  78. data/lib/measures/CoilCoolingWaterMultiplier/measure.rb +324 -0
  79. data/lib/measures/CoilCoolingWaterMultiplier/measure.xml +129 -0
  80. data/lib/measures/CoilCoolingWaterPercentChange/LICENSE.md +27 -0
  81. data/lib/measures/CoilCoolingWaterPercentChange/README.md +80 -0
  82. data/lib/measures/CoilCoolingWaterPercentChange/README.md.erb +42 -0
  83. data/lib/measures/CoilCoolingWaterPercentChange/measure.rb +311 -0
  84. data/lib/measures/CoilCoolingWaterPercentChange/measure.xml +129 -0
  85. data/lib/measures/CoilHeatingElectricMultiplier/LICENSE.md +27 -0
  86. data/lib/measures/CoilHeatingElectricMultiplier/README.md +48 -0
  87. data/lib/measures/CoilHeatingElectricMultiplier/README.md.erb +42 -0
  88. data/lib/measures/CoilHeatingElectricMultiplier/measure.rb +240 -0
  89. data/lib/measures/CoilHeatingElectricMultiplier/measure.xml +93 -0
  90. data/lib/measures/CoilHeatingElectricPercentChange/LICENSE.md +27 -0
  91. data/lib/measures/CoilHeatingElectricPercentChange/README.md +48 -0
  92. data/lib/measures/CoilHeatingElectricPercentChange/README.md.erb +42 -0
  93. data/lib/measures/CoilHeatingElectricPercentChange/measure.rb +231 -0
  94. data/lib/measures/CoilHeatingElectricPercentChange/measure.xml +93 -0
  95. data/lib/measures/CoilHeatingGasMultiplier/LICENSE.md +27 -0
  96. data/lib/measures/CoilHeatingGasMultiplier/README.md +64 -0
  97. data/lib/measures/CoilHeatingGasMultiplier/README.md.erb +42 -0
  98. data/lib/measures/CoilHeatingGasMultiplier/measure.rb +282 -0
  99. data/lib/measures/CoilHeatingGasMultiplier/measure.xml +111 -0
  100. data/lib/measures/CoilHeatingGasPercentChange/LICENSE.md +27 -0
  101. data/lib/measures/CoilHeatingGasPercentChange/README.md +64 -0
  102. data/lib/measures/CoilHeatingGasPercentChange/README.md.erb +42 -0
  103. data/lib/measures/CoilHeatingGasPercentChange/measure.rb +271 -0
  104. data/lib/measures/CoilHeatingGasPercentChange/measure.xml +111 -0
  105. data/lib/measures/CoilHeatingWaterMultiplier/LICENSE.md +27 -0
  106. data/lib/measures/CoilHeatingWaterMultiplier/README.md +48 -0
  107. data/lib/measures/CoilHeatingWaterMultiplier/README.md.erb +42 -0
  108. data/lib/measures/CoilHeatingWaterMultiplier/measure.rb +235 -0
  109. data/lib/measures/CoilHeatingWaterMultiplier/measure.xml +93 -0
  110. data/lib/measures/CoilHeatingWaterPercentChange/LICENSE.md +27 -0
  111. data/lib/measures/CoilHeatingWaterPercentChange/README.md +48 -0
  112. data/lib/measures/CoilHeatingWaterPercentChange/README.md.erb +42 -0
  113. data/lib/measures/CoilHeatingWaterPercentChange/measure.rb +226 -0
  114. data/lib/measures/CoilHeatingWaterPercentChange/measure.xml +93 -0
  115. data/lib/measures/ConstructionLayerZeroMaterialProperties/LICENSE.md +27 -0
  116. data/lib/measures/ConstructionLayerZeroMaterialProperties/README.md +88 -0
  117. data/lib/measures/ConstructionLayerZeroMaterialProperties/README.md.erb +42 -0
  118. data/lib/measures/ConstructionLayerZeroMaterialProperties/measure.rb +221 -0
  119. data/lib/measures/ConstructionLayerZeroMaterialProperties/measure.xml +194 -0
  120. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/LICENSE.md +27 -0
  121. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/README.md +40 -0
  122. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/README.md.erb +42 -0
  123. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/measure.rb +102 -0
  124. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/measure.xml +78 -0
  125. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/LICENSE.md +27 -0
  126. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/README.md +48 -0
  127. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/README.md.erb +42 -0
  128. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/measure.rb +263 -0
  129. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/measure.xml +97 -0
  130. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/LICENSE.md +27 -0
  131. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/README.md +48 -0
  132. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/README.md.erb +42 -0
  133. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/measure.rb +253 -0
  134. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/measure.xml +97 -0
  135. data/lib/measures/FansMultiplier/LICENSE.md +27 -0
  136. data/lib/measures/FansMultiplier/README.md +64 -0
  137. data/lib/measures/FansMultiplier/README.md.erb +42 -0
  138. data/lib/measures/FansMultiplier/measure.rb +297 -0
  139. data/lib/measures/FansMultiplier/measure.xml +166 -0
  140. data/lib/measures/FansPercentChange/LICENSE.md +27 -0
  141. data/lib/measures/FansPercentChange/README.md +64 -0
  142. data/lib/measures/FansPercentChange/README.md.erb +42 -0
  143. data/lib/measures/FansPercentChange/measure.rb +286 -0
  144. data/lib/measures/FansPercentChange/measure.xml +166 -0
  145. data/lib/measures/GeneralCalibrationMeasureMultiplier/LICENSE.md +27 -0
  146. data/lib/measures/GeneralCalibrationMeasureMultiplier/README.md +112 -0
  147. data/lib/measures/GeneralCalibrationMeasureMultiplier/README.md.erb +42 -0
  148. data/lib/measures/GeneralCalibrationMeasureMultiplier/measure.rb +639 -0
  149. data/lib/measures/GeneralCalibrationMeasureMultiplier/measure.xml +229 -0
  150. data/lib/measures/GeneralCalibrationMeasurePercentChange/LICENSE.md +27 -0
  151. data/lib/measures/GeneralCalibrationMeasurePercentChange/README.md +112 -0
  152. data/lib/measures/GeneralCalibrationMeasurePercentChange/README.md.erb +42 -0
  153. data/lib/measures/GeneralCalibrationMeasurePercentChange/measure.rb +756 -0
  154. data/lib/measures/GeneralCalibrationMeasurePercentChange/measure.xml +229 -0
  155. data/lib/measures/HardSizeHvac/LICENSE.md +27 -0
  156. data/lib/measures/HardSizeHvac/README.md +26 -0
  157. data/lib/measures/HardSizeHvac/README.md.erb +42 -0
  158. data/lib/measures/HardSizeHvac/measure.rb +88 -0
  159. data/lib/measures/HardSizeHvac/measure.xml +81 -0
  160. data/lib/measures/MaalkaMonthlyJSONUtilityData/LICENSE.md +27 -0
  161. data/lib/measures/MaalkaMonthlyJSONUtilityData/README.md +104 -0
  162. data/lib/measures/MaalkaMonthlyJSONUtilityData/README.md.erb +42 -0
  163. data/lib/measures/MaalkaMonthlyJSONUtilityData/measure.rb +304 -0
  164. data/lib/measures/MaalkaMonthlyJSONUtilityData/measure.xml +216 -0
  165. data/lib/measures/RValueOfInsulationForConstructionMultiplier/LICENSE.md +27 -0
  166. data/lib/measures/RValueOfInsulationForConstructionMultiplier/README.md +40 -0
  167. data/lib/measures/RValueOfInsulationForConstructionMultiplier/README.md.erb +42 -0
  168. data/lib/measures/RValueOfInsulationForConstructionMultiplier/measure.rb +196 -0
  169. data/lib/measures/RValueOfInsulationForConstructionMultiplier/measure.xml +132 -0
  170. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/LICENSE.md +27 -0
  171. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/README.md +40 -0
  172. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/README.md.erb +42 -0
  173. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/measure.rb +189 -0
  174. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/measure.xml +132 -0
  175. data/lib/measures/RoofThermalPropertiesMultiplier/LICENSE.md +27 -0
  176. data/lib/measures/RoofThermalPropertiesMultiplier/README.md +48 -0
  177. data/lib/measures/RoofThermalPropertiesMultiplier/README.md.erb +42 -0
  178. data/lib/measures/RoofThermalPropertiesMultiplier/measure.rb +263 -0
  179. data/lib/measures/RoofThermalPropertiesMultiplier/measure.xml +97 -0
  180. data/lib/measures/RoofThermalPropertiesPercentChange/LICENSE.md +27 -0
  181. data/lib/measures/RoofThermalPropertiesPercentChange/README.md +48 -0
  182. data/lib/measures/RoofThermalPropertiesPercentChange/README.md.erb +42 -0
  183. data/lib/measures/RoofThermalPropertiesPercentChange/measure.rb +253 -0
  184. data/lib/measures/RoofThermalPropertiesPercentChange/measure.xml +97 -0
  185. data/lib/measures/TimeseriesObjectiveFunction/LICENSE.md +27 -0
  186. data/lib/measures/TimeseriesObjectiveFunction/README.md +207 -0
  187. data/lib/measures/TimeseriesObjectiveFunction/README.md.erb +42 -0
  188. data/lib/measures/TimeseriesObjectiveFunction/measure.rb +748 -0
  189. data/lib/measures/TimeseriesObjectiveFunction/measure.xml +435 -0
  190. data/lib/measures/TimeseriesObjectiveFunction/resources/report.html.erb +288 -0
  191. data/lib/measures/TimeseriesPlot/LICENSE.md +27 -0
  192. data/lib/measures/TimeseriesPlot/README.md +56 -0
  193. data/lib/measures/TimeseriesPlot/README.md.erb +42 -0
  194. data/lib/measures/TimeseriesPlot/measure.rb +302 -0
  195. data/lib/measures/TimeseriesPlot/measure.xml +137 -0
  196. data/lib/measures/TimeseriesPlot/resources/report.html.erb +270 -0
  197. data/lib/measures/WaterHeaterMixedMultiplier/LICENSE.md +27 -0
  198. data/lib/measures/WaterHeaterMixedMultiplier/README.md +64 -0
  199. data/lib/measures/WaterHeaterMixedMultiplier/README.md.erb +42 -0
  200. data/lib/measures/WaterHeaterMixedMultiplier/measure.rb +255 -0
  201. data/lib/measures/WaterHeaterMixedMultiplier/measure.xml +180 -0
  202. data/lib/measures/WaterHeaterMixedPercentChange/LICENSE.md +27 -0
  203. data/lib/measures/WaterHeaterMixedPercentChange/README.md +64 -0
  204. data/lib/measures/WaterHeaterMixedPercentChange/README.md.erb +42 -0
  205. data/lib/measures/WaterHeaterMixedPercentChange/measure.rb +245 -0
  206. data/lib/measures/WaterHeaterMixedPercentChange/measure.xml +180 -0
  207. data/lib/measures/zone_report/LICENSE.md +27 -0
  208. data/lib/measures/zone_report/README.md +26 -0
  209. data/lib/measures/zone_report/README.md.erb +42 -0
  210. data/lib/measures/zone_report/measure.rb +706 -0
  211. data/lib/measures/zone_report/measure.xml +67 -0
  212. data/lib/measures/zone_report/resources/report.html.in +342 -0
  213. data/lib/openstudio-calibration-measures.rb +36 -0
  214. data/lib/openstudio/calibration_measures.rb +37 -0
  215. data/lib/openstudio/calibration_measures/extension.rb +49 -0
  216. data/lib/openstudio/calibration_measures/version.rb +40 -0
  217. data/openstudio-calibration.gemspec +30 -0
  218. metadata +331 -0
@@ -0,0 +1,27 @@
1
+ OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC. All rights reserved.
2
+
3
+ Redistribution and use in source and binary forms, with or without modification, are permitted
4
+ provided that the following conditions are met:
5
+
6
+ (1) Redistributions of source code must retain the above copyright notice, this list of conditions
7
+ and the following disclaimer.
8
+
9
+ (2) Redistributions in binary form must reproduce the above copyright notice, this list of conditions
10
+ and the following disclaimer in the documentation and/or other materials provided with the distribution.
11
+
12
+ (3) Neither the name of the copyright holder nor the names of any contributors may be used to endorse
13
+ or promote products derived from this software without specific prior written permission from the
14
+ respective party.
15
+
16
+ (4) Other than as required in clauses (1) and (2), distributions in any form of modifications or other
17
+ derivative works may not use the "OpenStudio" trademark, "OS", "os", or any other confusingly similar
18
+ designation without specific prior written permission from Alliance for Sustainable Energy, LLC.
19
+
20
+ THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED
21
+ WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
22
+ PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER, THE UNITED STATES GOVERNMENT,
23
+ OR ANY CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
24
+ DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,
25
+ OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
26
+ STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
27
+ SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
@@ -0,0 +1,80 @@
1
+
2
+
3
+ ###### (Automatically generated documentation)
4
+
5
+ # Cooling Coils Water Multiplier
6
+
7
+ ## Description
8
+ This is a general purpose measure to calibrate Water Cooling Coils with a Multiplier.
9
+
10
+ ## Modeler Description
11
+ It will be used for calibration of inlet water temperatures, inlet and outlet air temperatures and design flowrates. User can choose between a SINGLE coil or ALL the Coils.
12
+
13
+ ## Measure Type
14
+ ModelMeasure
15
+
16
+ ## Taxonomy
17
+
18
+
19
+ ## Arguments
20
+
21
+
22
+ ### Apply the Measure to a SINGLE Water Cooling Coil, ALL the Water Cooling Coils or NONE.
23
+
24
+ **Name:** coil,
25
+ **Type:** Choice,
26
+ **Units:** ,
27
+ **Required:** true,
28
+ **Model Dependent:** false
29
+
30
+ ### Multiplier for Design Water Flow Rate.
31
+ Multiplier for Design Water Flow Rate.
32
+ **Name:** design_water_flow_rate,
33
+ **Type:** Double,
34
+ **Units:** ,
35
+ **Required:** true,
36
+ **Model Dependent:** false
37
+
38
+ ### Multiplier for Design Air Flow Rate.
39
+ Multiplier for Design Air Flow Rate.
40
+ **Name:** design_air_flow_rate,
41
+ **Type:** Double,
42
+ **Units:** ,
43
+ **Required:** true,
44
+ **Model Dependent:** false
45
+
46
+ ### Multiplier for Inlet Water Temperature.
47
+ Multiplier for Inlet Water Temperature.
48
+ **Name:** design_inlet_water_temperature,
49
+ **Type:** Double,
50
+ **Units:** ,
51
+ **Required:** true,
52
+ **Model Dependent:** false
53
+
54
+ ### Multiplier for Inlet Air Temperature.
55
+ Multiplier for Inlet Air Temperature.
56
+ **Name:** design_inlet_air_temperature,
57
+ **Type:** Double,
58
+ **Units:** ,
59
+ **Required:** true,
60
+ **Model Dependent:** false
61
+
62
+ ### Multiplier for Outlet Air Temperature.
63
+ Multiplier for Outlet Air Temperature.
64
+ **Name:** design_outlet_air_temperature,
65
+ **Type:** Double,
66
+ **Units:** ,
67
+ **Required:** true,
68
+ **Model Dependent:** false
69
+
70
+ ### Multiplier for Inlet Air Humidity Ratio.
71
+ Multiplier for Inlet Air Humidity Ratio.
72
+ **Name:** design_inlet_air_humidity_ratio,
73
+ **Type:** Double,
74
+ **Units:** ,
75
+ **Required:** true,
76
+ **Model Dependent:** false
77
+
78
+
79
+
80
+
@@ -0,0 +1,42 @@
1
+ <%#= README.md.erb is used to auto-generate README.md. %>
2
+ <%#= To manually maintain README.md throw away README.md.erb and manually edit README.md %>
3
+ ###### (Automatically generated documentation)
4
+
5
+ # <%= name %>
6
+
7
+ ## Description
8
+ <%= description %>
9
+
10
+ ## Modeler Description
11
+ <%= modelerDescription %>
12
+
13
+ ## Measure Type
14
+ <%= measureType %>
15
+
16
+ ## Taxonomy
17
+ <%= taxonomy %>
18
+
19
+ ## Arguments
20
+
21
+ <% arguments.each do |argument| %>
22
+ ### <%= argument[:display_name] %>
23
+ <%= argument[:description] %>
24
+ **Name:** <%= argument[:name] %>,
25
+ **Type:** <%= argument[:type] %>,
26
+ **Units:** <%= argument[:units] %>,
27
+ **Required:** <%= argument[:required] %>,
28
+ **Model Dependent:** <%= argument[:model_dependent] %>
29
+ <% end %>
30
+
31
+ <% if arguments.size == 0 %>
32
+ <%= "This measure does not have any user arguments" %>
33
+ <% end %>
34
+
35
+ <% if outputs.size > 0 %>
36
+ ## Outputs
37
+ <% output_names = [] %>
38
+ <% outputs.each do |output| %>
39
+ <% output_names << output[:display_name] %>
40
+ <% end %>
41
+ <%= output_names.join(", ") %>
42
+ <% end %>
@@ -0,0 +1,324 @@
1
+ # *******************************************************************************
2
+ # OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC.
3
+ # All rights reserved.
4
+ # Redistribution and use in source and binary forms, with or without
5
+ # modification, are permitted provided that the following conditions are met:
6
+ #
7
+ # (1) Redistributions of source code must retain the above copyright notice,
8
+ # this list of conditions and the following disclaimer.
9
+ #
10
+ # (2) Redistributions in binary form must reproduce the above copyright notice,
11
+ # this list of conditions and the following disclaimer in the documentation
12
+ # and/or other materials provided with the distribution.
13
+ #
14
+ # (3) Neither the name of the copyright holder nor the names of any contributors
15
+ # may be used to endorse or promote products derived from this software without
16
+ # specific prior written permission from the respective party.
17
+ #
18
+ # (4) Other than as required in clauses (1) and (2), distributions in any form
19
+ # of modifications or other derivative works may not use the "OpenStudio"
20
+ # trademark, "OS", "os", or any other confusingly similar designation without
21
+ # specific prior written permission from Alliance for Sustainable Energy, LLC.
22
+ #
23
+ # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS
24
+ # "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
25
+ # THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
26
+ # ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE
27
+ # UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF
28
+ # THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
29
+ # EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT
30
+ # OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
31
+ # INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
32
+ # STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
33
+ # OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
34
+ # *******************************************************************************
35
+
36
+ # start the measure
37
+ class CoilCoolingWaterMultiplier < OpenStudio::Measure::ModelMeasure
38
+ # human readable name
39
+ def name
40
+ 'Cooling Coils Water Multiplier'
41
+ end
42
+
43
+ # human readable description
44
+ def description
45
+ 'This is a general purpose measure to calibrate Water Cooling Coils with a Multiplier.'
46
+ end
47
+
48
+ # human readable description of modeling approach
49
+ def modeler_description
50
+ 'It will be used for calibration of inlet water temperatures, inlet and outlet air temperatures and design flowrates. User can choose between a SINGLE coil or ALL the Coils.'
51
+ end
52
+
53
+ def change_name(object, design_water_flow_rate, design_air_flow_rate, design_inlet_water_temperature, design_inlet_air_temperature, design_outlet_air_temperature, design_inlet_air_humidity_ratio)
54
+ nameString = object.name.get.to_s
55
+ if design_water_flow_rate != 1.0
56
+ nameString += " #{design_water_flow_rate.round(2)}x waterDFR"
57
+ end
58
+ if design_air_flow_rate != 1.0
59
+ nameString += " #{design_air_flow_rate.round(2)}x airDFR"
60
+ end
61
+ if design_inlet_water_temperature != 1.0
62
+ nameString += " #{design_inlet_water_temperature.round(2)}x DIWT"
63
+ end
64
+ if design_inlet_air_temperature != 1.0
65
+ nameString += " #{design_inlet_air_temperature.round(2)}x DIAT"
66
+ end
67
+ if design_outlet_air_temperature != 1.0
68
+ nameString += " #{design_outlet_air_temperature.round(2)}x DOAT"
69
+ end
70
+ if design_inlet_air_humidity_ratio != 1.0
71
+ nameString += " #{design_inlet_air_humidity_ratio.round(2)}x DIAHR"
72
+ end
73
+ object.setName(nameString)
74
+ end
75
+
76
+ def check_multiplier(runner, multiplier)
77
+ if multiplier < 0
78
+ runner.registerError("Multiplier #{multiplier} cannot be negative.")
79
+ false
80
+ end
81
+ end
82
+
83
+ # define the arguments that the user will input
84
+ def arguments(model)
85
+ args = OpenStudio::Measure::OSArgumentVector.new
86
+
87
+ # populate choice argument for constructions that are applied to surfaces in the model
88
+ loop_handles = OpenStudio::StringVector.new
89
+ loop_display_names = OpenStudio::StringVector.new
90
+
91
+ # putting air loops and names into hash
92
+ loop_args = model.getAirLoopHVACs
93
+ loop_args_hash = {}
94
+ loop_args.each do |loop_arg|
95
+ loop_args_hash[loop_arg.name.to_s] = loop_arg
96
+ end
97
+
98
+ # looping through sorted hash of air loops
99
+ loop_args_hash.sort.map do |_key, value|
100
+ show_loop = false
101
+ components = value.supplyComponents
102
+ components.each do |component|
103
+ next if component.to_CoilCoolingWater.empty?
104
+ show_loop = true
105
+ loop_handles << component.handle.to_s
106
+ loop_display_names << component.name.to_s
107
+ end
108
+
109
+ # if loop as object of correct type then add to hash.
110
+ # if show_loop == true
111
+ # loop_handles << value.handle.to_s
112
+ # loop_display_names << key
113
+ # end
114
+ end
115
+
116
+ # add building to string vector with space type
117
+ building = model.getBuilding
118
+ loop_handles << building.handle.to_s
119
+ loop_display_names << '*All Water Cooling Coils*'
120
+ loop_handles << '0'
121
+ loop_display_names << '*None*'
122
+
123
+ # make a choice argument for space type
124
+ coil_arg = OpenStudio::Measure::OSArgument.makeChoiceArgument('coil', loop_handles, loop_display_names)
125
+ coil_arg.setDisplayName('Apply the Measure to a SINGLE Water Cooling Coil, ALL the Water Cooling Coils or NONE.')
126
+ coil_arg.setDefaultValue('*All Water Cooling Coils*') # if no space type is chosen this will run on the entire building
127
+ args << coil_arg
128
+
129
+ # design_water_flow_rate
130
+ design_water_flow_rate = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_water_flow_rate', true)
131
+ design_water_flow_rate.setDisplayName('Multiplier for Design Water Flow Rate.')
132
+ design_water_flow_rate.setDescription('Multiplier for Design Water Flow Rate.')
133
+ design_water_flow_rate.setDefaultValue(1.0)
134
+ args << design_water_flow_rate
135
+
136
+ # design_air_flow_rate
137
+ design_air_flow_rate = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_air_flow_rate', true)
138
+ design_air_flow_rate.setDisplayName('Multiplier for Design Air Flow Rate.')
139
+ design_air_flow_rate.setDescription('Multiplier for Design Air Flow Rate.')
140
+ design_air_flow_rate.setDefaultValue(1.0)
141
+ args << design_air_flow_rate
142
+
143
+ # design_inlet_water_temperature
144
+ design_inlet_water_temperature = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_inlet_water_temperature', true)
145
+ design_inlet_water_temperature.setDisplayName('Multiplier for Inlet Water Temperature.')
146
+ design_inlet_water_temperature.setDescription('Multiplier for Inlet Water Temperature.')
147
+ design_inlet_water_temperature.setDefaultValue(1.0)
148
+ args << design_inlet_water_temperature
149
+
150
+ # design_inlet_air_temperature
151
+ design_inlet_air_temperature = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_inlet_air_temperature', true)
152
+ design_inlet_air_temperature.setDisplayName('Multiplier for Inlet Air Temperature.')
153
+ design_inlet_air_temperature.setDescription('Multiplier for Inlet Air Temperature.')
154
+ design_inlet_air_temperature.setDefaultValue(1.0)
155
+ args << design_inlet_air_temperature
156
+
157
+ # design_outlet_air_temperature
158
+ design_outlet_air_temperature = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_outlet_air_temperature', true)
159
+ design_outlet_air_temperature.setDisplayName('Multiplier for Outlet Air Temperature.')
160
+ design_outlet_air_temperature.setDescription('Multiplier for Outlet Air Temperature.')
161
+ design_outlet_air_temperature.setDefaultValue(1.0)
162
+ args << design_outlet_air_temperature
163
+
164
+ # design_inlet_air_humidity_ratio
165
+ design_inlet_air_humidity_ratio = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_inlet_air_humidity_ratio', true)
166
+ design_inlet_air_humidity_ratio.setDisplayName('Multiplier for Inlet Air Humidity Ratio.')
167
+ design_inlet_air_humidity_ratio.setDescription('Multiplier for Inlet Air Humidity Ratio.')
168
+ design_inlet_air_humidity_ratio.setDefaultValue(1.0)
169
+ args << design_inlet_air_humidity_ratio
170
+
171
+ args
172
+ end
173
+
174
+ # define what happens when the measure is run
175
+ def run(model, runner, user_arguments)
176
+ super(model, runner, user_arguments)
177
+
178
+ # use the built-in error checking
179
+ unless runner.validateUserArguments(arguments(model), user_arguments)
180
+ return false
181
+ end
182
+
183
+ # assign the user inputs to variables
184
+ coil_object = runner.getOptionalWorkspaceObjectChoiceValue('coil', user_arguments, model)
185
+ coil_handle = runner.getStringArgumentValue('coil', user_arguments)
186
+
187
+ design_air_flow_rate = runner.getDoubleArgumentValue('design_air_flow_rate', user_arguments)
188
+ check_multiplier(runner, design_air_flow_rate)
189
+ design_water_flow_rate = runner.getDoubleArgumentValue('design_water_flow_rate', user_arguments)
190
+ check_multiplier(runner, design_water_flow_rate)
191
+ design_inlet_air_temperature = runner.getDoubleArgumentValue('design_inlet_air_temperature', user_arguments)
192
+ check_multiplier(runner, design_inlet_air_temperature)
193
+ design_outlet_air_temperature = runner.getDoubleArgumentValue('design_outlet_air_temperature', user_arguments)
194
+ check_multiplier(runner, design_outlet_air_temperature)
195
+ design_inlet_air_humidity_ratio = runner.getDoubleArgumentValue('design_inlet_air_humidity_ratio', user_arguments)
196
+ check_multiplier(runner, design_inlet_air_humidity_ratio)
197
+ design_inlet_water_temperature = runner.getDoubleArgumentValue('design_inlet_water_temperature', user_arguments)
198
+ check_multiplier(runner, design_inlet_water_temperature)
199
+
200
+ # find objects to change
201
+ coils = []
202
+ building = model.getBuilding
203
+ building_handle = building.handle.to_s
204
+ runner.registerInfo("coil_handle: #{coil_handle}")
205
+ # setup coils
206
+ if coil_handle == building_handle
207
+ # Use ALL coils
208
+ runner.registerInfo('Applying change to ALL Coils')
209
+ loops = model.getAirLoopHVACs
210
+ # loop through air loops
211
+ loops.each do |loop|
212
+ supply_components = loop.supplyComponents
213
+ # find coils on loops
214
+ supply_components.each do |supply_component|
215
+ unless supply_component.to_CoilCoolingWater.empty?
216
+ coils << supply_component.to_CoilCoolingWater.get
217
+ end
218
+ end
219
+ end
220
+ elsif coil_handle == 0.to_s
221
+ # coils set to NONE so do nothing
222
+ runner.registerInfo('Applying change to NONE Coils')
223
+ elsif !coil_handle.empty?
224
+ # Single coil handle found, check if object is good
225
+ if !coil_object.get.to_CoilCoolingWater.empty?
226
+ runner.registerInfo("Applying change to #{coil_object.get.name} coil")
227
+ coils << coil_object.get.to_CoilCoolingWater.get
228
+ else
229
+ runner.registerError("coil with handle #{coil_handle} could not be found.")
230
+ end
231
+ else
232
+ runner.registerError('coil handle is empty.')
233
+ return false
234
+ end
235
+
236
+ # report initial condition of model
237
+ runner.registerInitialCondition("Coils to change: #{coils.size}")
238
+ runner.registerInfo("Coils to change: #{coils.size}")
239
+ altered_coils = []
240
+ altered_capacity = []
241
+ altered_coilefficiency = []
242
+ # loop through coils
243
+ coils.each do |coil|
244
+ altered_coil = false
245
+ # design_air_flow_rate
246
+ if design_air_flow_rate != 1.0
247
+ if coil.designAirFlowRate.is_initialized
248
+ runner.registerInfo("Applying designAirFlowRate #{design_air_flow_rate}x multiplier to #{coil.name.get}.")
249
+ coil.setDesignAirFlowRate(coil.designAirFlowRate.get * design_air_flow_rate)
250
+ altered_capacity << coil.handle.to_s
251
+ altered_coil = true
252
+ end
253
+ end
254
+
255
+ # modify design_water_flow_rate
256
+ if design_water_flow_rate != 1.0
257
+ if coil.designWaterFlowRate.is_initialized
258
+ runner.registerInfo("Applying designWaterFlowRate #{design_water_flow_rate}x multiplier to #{coil.name.get}.")
259
+ coil.setDesignWaterFlowRate(coil.designWaterFlowRate.get * design_water_flow_rate)
260
+ altered_coilefficiency << coil.handle.to_s
261
+ altered_coil = true
262
+ end
263
+ end
264
+
265
+ # design_inlet_air_temperature
266
+ if design_inlet_air_temperature != 1.0
267
+ if coil.designInletAirTemperature.is_initialized
268
+ runner.registerInfo("Applying designInletAirTemperature #{design_inlet_air_temperature}x multiplier to #{coil.name.get}.")
269
+ coil.setDesignInletAirTemperature(coil.designInletAirTemperature.get * design_inlet_air_temperature)
270
+ altered_capacity << coil.handle.to_s
271
+ altered_coil = true
272
+ end
273
+ end
274
+
275
+ # modify design_inlet_water_temperature
276
+ if design_inlet_water_temperature != 1.0
277
+ if coil.designInletWaterTemperature.is_initialized
278
+ runner.registerInfo("Applying designInletWaterTemperature #{design_inlet_water_temperature}x multiplier to #{coil.name.get}.")
279
+ coil.setDesignInletWaterTemperature(coil.designInletWaterTemperature.get * design_inlet_water_temperature)
280
+ altered_coilefficiency << coil.handle.to_s
281
+ altered_coil = true
282
+ end
283
+ end
284
+
285
+ # design_inlet_air_humidity_ratio
286
+ if design_inlet_air_humidity_ratio != 1.0
287
+ if coil.designInletAirHumidityRatio.is_initialized
288
+ runner.registerInfo("Applying designInletAirHumidityRatio #{design_inlet_air_humidity_ratio}x multiplier to #{coil.name.get}.")
289
+ coil.setDesignInletAirHumidityRatio(coil.designInletAirHumidityRatio.get * design_inlet_air_humidity_ratio)
290
+ altered_capacity << coil.handle.to_s
291
+ altered_coil = true
292
+ end
293
+ end
294
+
295
+ # modify design_outlet_air_temperature
296
+ if design_outlet_air_temperature != 1.0
297
+ if coil.designOutletAirTemperature.is_initialized
298
+ runner.registerInfo("Applying designOutletAirTemperature #{design_outlet_air_temperature}x multiplier to #{coil.name.get}.")
299
+ coil.setDesignOutletAirTemperature(coil.designOutletAirTemperature.get * design_outlet_air_temperature)
300
+ altered_coilefficiency << coil.handle.to_s
301
+ altered_coil = true
302
+ end
303
+ end
304
+ next unless altered_coil
305
+ altered_coils << coil.handle.to_s
306
+ change_name(coil, design_water_flow_rate, design_air_flow_rate, design_inlet_water_temperature, design_inlet_air_temperature, design_outlet_air_temperature, design_inlet_air_humidity_ratio)
307
+ runner.registerInfo("coil name changed to: #{coil.name.get}")
308
+ end # end coil loop
309
+
310
+ # na if nothing in model to look at
311
+ if altered_coils.empty?
312
+ runner.registerAsNotApplicable('No Coils were altered in the model')
313
+ return true
314
+ end
315
+
316
+ # report final condition of model
317
+ runner.registerFinalCondition("#{altered_coils.size} Coils objects were altered.")
318
+
319
+ true
320
+ end
321
+ end
322
+
323
+ # register the measure to be used by the application
324
+ CoilCoolingWaterMultiplier.new.registerWithApplication