openstudio-calibration 0.1.2

Sign up to get free protection for your applications and to get access to all the features.
Files changed (218) hide show
  1. checksums.yaml +7 -0
  2. data/.gitignore +29 -0
  3. data/CHANGELOG.md +14 -0
  4. data/Gemfile +20 -0
  5. data/Jenkinsfile +6 -0
  6. data/LICENSE.md +27 -0
  7. data/README.md +33 -0
  8. data/Rakefile +50 -0
  9. data/doc_templates/LICENSE.md +27 -0
  10. data/doc_templates/README.md.erb +42 -0
  11. data/doc_templates/copyright_erb.txt +36 -0
  12. data/doc_templates/copyright_js.txt +4 -0
  13. data/doc_templates/copyright_ruby.txt +34 -0
  14. data/lib/files/.gitkeep +0 -0
  15. data/lib/measures/AddMonthlyJSONUtilityData/LICENSE.md +27 -0
  16. data/lib/measures/AddMonthlyJSONUtilityData/README.md +96 -0
  17. data/lib/measures/AddMonthlyJSONUtilityData/README.md.erb +42 -0
  18. data/lib/measures/AddMonthlyJSONUtilityData/measure.rb +280 -0
  19. data/lib/measures/AddMonthlyJSONUtilityData/measure.xml +163 -0
  20. data/lib/measures/AddMonthlyUtilityData/LICENSE.md +27 -0
  21. data/lib/measures/AddMonthlyUtilityData/README.md +64 -0
  22. data/lib/measures/AddMonthlyUtilityData/README.md.erb +42 -0
  23. data/lib/measures/AddMonthlyUtilityData/measure.rb +312 -0
  24. data/lib/measures/AddMonthlyUtilityData/measure.xml +115 -0
  25. data/lib/measures/AddMonthlyUtilityData/tests/AddMonthlyUtilityData_Test.rb +88 -0
  26. data/lib/measures/AddMonthlyUtilityData/tests/electric_billed_usages.json +198 -0
  27. data/lib/measures/AddMonthlyUtilityData/tests/gas_billed_usages.json +198 -0
  28. data/lib/measures/CalibrationReports/LICENSE.md +27 -0
  29. data/lib/measures/CalibrationReports/README.md +26 -0
  30. data/lib/measures/CalibrationReports/README.md.erb +42 -0
  31. data/lib/measures/CalibrationReports/measure.rb +511 -0
  32. data/lib/measures/CalibrationReports/measure.xml +98 -0
  33. data/lib/measures/CalibrationReports/resources/report.html.in +379 -0
  34. data/lib/measures/CalibrationReports/tests/CalibrationReports_Test.rb +523 -0
  35. data/lib/measures/CalibrationReports/tests/ExampleModel.osm +10497 -0
  36. data/lib/measures/CalibrationReports/tests/ExampleModelNoDemandInput.osm +10560 -0
  37. data/lib/measures/CalibrationReports/tests/ExampleModelNoGasInput.osm +10456 -0
  38. data/lib/measures/CalibrationReports/tests/USA_CO_Golden-NREL.724666_TMY3.epw +8768 -0
  39. data/lib/measures/CalibrationReportsEnhanced/LICENSE.md +27 -0
  40. data/lib/measures/CalibrationReportsEnhanced/README.md +143 -0
  41. data/lib/measures/CalibrationReportsEnhanced/README.md.erb +42 -0
  42. data/lib/measures/CalibrationReportsEnhanced/measure.rb +798 -0
  43. data/lib/measures/CalibrationReportsEnhanced/measure.xml +372 -0
  44. data/lib/measures/CalibrationReportsEnhanced/resources/report.html.in +380 -0
  45. data/lib/measures/CalibrationReportsEnhanced/tests/CalibrationReportsEnhanced_Test.rb +734 -0
  46. data/lib/measures/CalibrationReportsEnhanced/tests/ExampleModel.osm +10497 -0
  47. data/lib/measures/CalibrationReportsEnhanced/tests/ExampleModel_FuelOil.osm +12740 -0
  48. data/lib/measures/CalibrationReportsEnhanced/tests/USA_CO_Golden-NREL.724666_TMY3.epw +8768 -0
  49. data/lib/measures/CalibrationReportsEnhanced21/LICENSE.md +27 -0
  50. data/lib/measures/CalibrationReportsEnhanced21/README.md +109 -0
  51. data/lib/measures/CalibrationReportsEnhanced21/README.md.erb +42 -0
  52. data/lib/measures/CalibrationReportsEnhanced21/measure.rb +690 -0
  53. data/lib/measures/CalibrationReportsEnhanced21/measure.xml +269 -0
  54. data/lib/measures/CalibrationReportsEnhanced21/resources/report.html.in +380 -0
  55. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/LICENSE.md +27 -0
  56. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/README.md +48 -0
  57. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/README.md.erb +42 -0
  58. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/measure.rb +237 -0
  59. data/lib/measures/CoilCoolingDXSingleSpeedMultiplier/measure.xml +93 -0
  60. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/LICENSE.md +27 -0
  61. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/README.md +48 -0
  62. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/README.md.erb +42 -0
  63. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/measure.rb +228 -0
  64. data/lib/measures/CoilCoolingDXSingleSpeedPercentChange/measure.xml +93 -0
  65. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/LICENSE.md +27 -0
  66. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/README.md +64 -0
  67. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/README.md.erb +42 -0
  68. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/measure.rb +280 -0
  69. data/lib/measures/CoilCoolingDXTwoSpeedMultiplier/measure.xml +111 -0
  70. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/LICENSE.md +27 -0
  71. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/README.md +64 -0
  72. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/README.md.erb +42 -0
  73. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/measure.rb +270 -0
  74. data/lib/measures/CoilCoolingDXTwoSpeedPercentChange/measure.xml +111 -0
  75. data/lib/measures/CoilCoolingWaterMultiplier/LICENSE.md +27 -0
  76. data/lib/measures/CoilCoolingWaterMultiplier/README.md +80 -0
  77. data/lib/measures/CoilCoolingWaterMultiplier/README.md.erb +42 -0
  78. data/lib/measures/CoilCoolingWaterMultiplier/measure.rb +324 -0
  79. data/lib/measures/CoilCoolingWaterMultiplier/measure.xml +129 -0
  80. data/lib/measures/CoilCoolingWaterPercentChange/LICENSE.md +27 -0
  81. data/lib/measures/CoilCoolingWaterPercentChange/README.md +80 -0
  82. data/lib/measures/CoilCoolingWaterPercentChange/README.md.erb +42 -0
  83. data/lib/measures/CoilCoolingWaterPercentChange/measure.rb +311 -0
  84. data/lib/measures/CoilCoolingWaterPercentChange/measure.xml +129 -0
  85. data/lib/measures/CoilHeatingElectricMultiplier/LICENSE.md +27 -0
  86. data/lib/measures/CoilHeatingElectricMultiplier/README.md +48 -0
  87. data/lib/measures/CoilHeatingElectricMultiplier/README.md.erb +42 -0
  88. data/lib/measures/CoilHeatingElectricMultiplier/measure.rb +240 -0
  89. data/lib/measures/CoilHeatingElectricMultiplier/measure.xml +93 -0
  90. data/lib/measures/CoilHeatingElectricPercentChange/LICENSE.md +27 -0
  91. data/lib/measures/CoilHeatingElectricPercentChange/README.md +48 -0
  92. data/lib/measures/CoilHeatingElectricPercentChange/README.md.erb +42 -0
  93. data/lib/measures/CoilHeatingElectricPercentChange/measure.rb +231 -0
  94. data/lib/measures/CoilHeatingElectricPercentChange/measure.xml +93 -0
  95. data/lib/measures/CoilHeatingGasMultiplier/LICENSE.md +27 -0
  96. data/lib/measures/CoilHeatingGasMultiplier/README.md +64 -0
  97. data/lib/measures/CoilHeatingGasMultiplier/README.md.erb +42 -0
  98. data/lib/measures/CoilHeatingGasMultiplier/measure.rb +282 -0
  99. data/lib/measures/CoilHeatingGasMultiplier/measure.xml +111 -0
  100. data/lib/measures/CoilHeatingGasPercentChange/LICENSE.md +27 -0
  101. data/lib/measures/CoilHeatingGasPercentChange/README.md +64 -0
  102. data/lib/measures/CoilHeatingGasPercentChange/README.md.erb +42 -0
  103. data/lib/measures/CoilHeatingGasPercentChange/measure.rb +271 -0
  104. data/lib/measures/CoilHeatingGasPercentChange/measure.xml +111 -0
  105. data/lib/measures/CoilHeatingWaterMultiplier/LICENSE.md +27 -0
  106. data/lib/measures/CoilHeatingWaterMultiplier/README.md +48 -0
  107. data/lib/measures/CoilHeatingWaterMultiplier/README.md.erb +42 -0
  108. data/lib/measures/CoilHeatingWaterMultiplier/measure.rb +235 -0
  109. data/lib/measures/CoilHeatingWaterMultiplier/measure.xml +93 -0
  110. data/lib/measures/CoilHeatingWaterPercentChange/LICENSE.md +27 -0
  111. data/lib/measures/CoilHeatingWaterPercentChange/README.md +48 -0
  112. data/lib/measures/CoilHeatingWaterPercentChange/README.md.erb +42 -0
  113. data/lib/measures/CoilHeatingWaterPercentChange/measure.rb +226 -0
  114. data/lib/measures/CoilHeatingWaterPercentChange/measure.xml +93 -0
  115. data/lib/measures/ConstructionLayerZeroMaterialProperties/LICENSE.md +27 -0
  116. data/lib/measures/ConstructionLayerZeroMaterialProperties/README.md +88 -0
  117. data/lib/measures/ConstructionLayerZeroMaterialProperties/README.md.erb +42 -0
  118. data/lib/measures/ConstructionLayerZeroMaterialProperties/measure.rb +221 -0
  119. data/lib/measures/ConstructionLayerZeroMaterialProperties/measure.xml +194 -0
  120. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/LICENSE.md +27 -0
  121. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/README.md +40 -0
  122. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/README.md.erb +42 -0
  123. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/measure.rb +102 -0
  124. data/lib/measures/ElectricBaseboardEfficiencyAndCapacity/measure.xml +78 -0
  125. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/LICENSE.md +27 -0
  126. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/README.md +48 -0
  127. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/README.md.erb +42 -0
  128. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/measure.rb +263 -0
  129. data/lib/measures/ExteriorWallThermalPropertiesMultiplier/measure.xml +97 -0
  130. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/LICENSE.md +27 -0
  131. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/README.md +48 -0
  132. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/README.md.erb +42 -0
  133. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/measure.rb +253 -0
  134. data/lib/measures/ExteriorWallThermalPropertiesPercentChange/measure.xml +97 -0
  135. data/lib/measures/FansMultiplier/LICENSE.md +27 -0
  136. data/lib/measures/FansMultiplier/README.md +64 -0
  137. data/lib/measures/FansMultiplier/README.md.erb +42 -0
  138. data/lib/measures/FansMultiplier/measure.rb +297 -0
  139. data/lib/measures/FansMultiplier/measure.xml +166 -0
  140. data/lib/measures/FansPercentChange/LICENSE.md +27 -0
  141. data/lib/measures/FansPercentChange/README.md +64 -0
  142. data/lib/measures/FansPercentChange/README.md.erb +42 -0
  143. data/lib/measures/FansPercentChange/measure.rb +286 -0
  144. data/lib/measures/FansPercentChange/measure.xml +166 -0
  145. data/lib/measures/GeneralCalibrationMeasureMultiplier/LICENSE.md +27 -0
  146. data/lib/measures/GeneralCalibrationMeasureMultiplier/README.md +112 -0
  147. data/lib/measures/GeneralCalibrationMeasureMultiplier/README.md.erb +42 -0
  148. data/lib/measures/GeneralCalibrationMeasureMultiplier/measure.rb +639 -0
  149. data/lib/measures/GeneralCalibrationMeasureMultiplier/measure.xml +229 -0
  150. data/lib/measures/GeneralCalibrationMeasurePercentChange/LICENSE.md +27 -0
  151. data/lib/measures/GeneralCalibrationMeasurePercentChange/README.md +112 -0
  152. data/lib/measures/GeneralCalibrationMeasurePercentChange/README.md.erb +42 -0
  153. data/lib/measures/GeneralCalibrationMeasurePercentChange/measure.rb +756 -0
  154. data/lib/measures/GeneralCalibrationMeasurePercentChange/measure.xml +229 -0
  155. data/lib/measures/HardSizeHvac/LICENSE.md +27 -0
  156. data/lib/measures/HardSizeHvac/README.md +26 -0
  157. data/lib/measures/HardSizeHvac/README.md.erb +42 -0
  158. data/lib/measures/HardSizeHvac/measure.rb +88 -0
  159. data/lib/measures/HardSizeHvac/measure.xml +81 -0
  160. data/lib/measures/MaalkaMonthlyJSONUtilityData/LICENSE.md +27 -0
  161. data/lib/measures/MaalkaMonthlyJSONUtilityData/README.md +104 -0
  162. data/lib/measures/MaalkaMonthlyJSONUtilityData/README.md.erb +42 -0
  163. data/lib/measures/MaalkaMonthlyJSONUtilityData/measure.rb +304 -0
  164. data/lib/measures/MaalkaMonthlyJSONUtilityData/measure.xml +216 -0
  165. data/lib/measures/RValueOfInsulationForConstructionMultiplier/LICENSE.md +27 -0
  166. data/lib/measures/RValueOfInsulationForConstructionMultiplier/README.md +40 -0
  167. data/lib/measures/RValueOfInsulationForConstructionMultiplier/README.md.erb +42 -0
  168. data/lib/measures/RValueOfInsulationForConstructionMultiplier/measure.rb +196 -0
  169. data/lib/measures/RValueOfInsulationForConstructionMultiplier/measure.xml +132 -0
  170. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/LICENSE.md +27 -0
  171. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/README.md +40 -0
  172. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/README.md.erb +42 -0
  173. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/measure.rb +189 -0
  174. data/lib/measures/RValueOfInsulationForConstructionPercentageChange/measure.xml +132 -0
  175. data/lib/measures/RoofThermalPropertiesMultiplier/LICENSE.md +27 -0
  176. data/lib/measures/RoofThermalPropertiesMultiplier/README.md +48 -0
  177. data/lib/measures/RoofThermalPropertiesMultiplier/README.md.erb +42 -0
  178. data/lib/measures/RoofThermalPropertiesMultiplier/measure.rb +263 -0
  179. data/lib/measures/RoofThermalPropertiesMultiplier/measure.xml +97 -0
  180. data/lib/measures/RoofThermalPropertiesPercentChange/LICENSE.md +27 -0
  181. data/lib/measures/RoofThermalPropertiesPercentChange/README.md +48 -0
  182. data/lib/measures/RoofThermalPropertiesPercentChange/README.md.erb +42 -0
  183. data/lib/measures/RoofThermalPropertiesPercentChange/measure.rb +253 -0
  184. data/lib/measures/RoofThermalPropertiesPercentChange/measure.xml +97 -0
  185. data/lib/measures/TimeseriesObjectiveFunction/LICENSE.md +27 -0
  186. data/lib/measures/TimeseriesObjectiveFunction/README.md +207 -0
  187. data/lib/measures/TimeseriesObjectiveFunction/README.md.erb +42 -0
  188. data/lib/measures/TimeseriesObjectiveFunction/measure.rb +748 -0
  189. data/lib/measures/TimeseriesObjectiveFunction/measure.xml +435 -0
  190. data/lib/measures/TimeseriesObjectiveFunction/resources/report.html.erb +288 -0
  191. data/lib/measures/TimeseriesPlot/LICENSE.md +27 -0
  192. data/lib/measures/TimeseriesPlot/README.md +56 -0
  193. data/lib/measures/TimeseriesPlot/README.md.erb +42 -0
  194. data/lib/measures/TimeseriesPlot/measure.rb +302 -0
  195. data/lib/measures/TimeseriesPlot/measure.xml +137 -0
  196. data/lib/measures/TimeseriesPlot/resources/report.html.erb +270 -0
  197. data/lib/measures/WaterHeaterMixedMultiplier/LICENSE.md +27 -0
  198. data/lib/measures/WaterHeaterMixedMultiplier/README.md +64 -0
  199. data/lib/measures/WaterHeaterMixedMultiplier/README.md.erb +42 -0
  200. data/lib/measures/WaterHeaterMixedMultiplier/measure.rb +255 -0
  201. data/lib/measures/WaterHeaterMixedMultiplier/measure.xml +180 -0
  202. data/lib/measures/WaterHeaterMixedPercentChange/LICENSE.md +27 -0
  203. data/lib/measures/WaterHeaterMixedPercentChange/README.md +64 -0
  204. data/lib/measures/WaterHeaterMixedPercentChange/README.md.erb +42 -0
  205. data/lib/measures/WaterHeaterMixedPercentChange/measure.rb +245 -0
  206. data/lib/measures/WaterHeaterMixedPercentChange/measure.xml +180 -0
  207. data/lib/measures/zone_report/LICENSE.md +27 -0
  208. data/lib/measures/zone_report/README.md +26 -0
  209. data/lib/measures/zone_report/README.md.erb +42 -0
  210. data/lib/measures/zone_report/measure.rb +706 -0
  211. data/lib/measures/zone_report/measure.xml +67 -0
  212. data/lib/measures/zone_report/resources/report.html.in +342 -0
  213. data/lib/openstudio-calibration-measures.rb +36 -0
  214. data/lib/openstudio/calibration_measures.rb +37 -0
  215. data/lib/openstudio/calibration_measures/extension.rb +49 -0
  216. data/lib/openstudio/calibration_measures/version.rb +40 -0
  217. data/openstudio-calibration.gemspec +30 -0
  218. metadata +331 -0
@@ -0,0 +1,27 @@
1
+ OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC. All rights reserved.
2
+
3
+ Redistribution and use in source and binary forms, with or without modification, are permitted
4
+ provided that the following conditions are met:
5
+
6
+ (1) Redistributions of source code must retain the above copyright notice, this list of conditions
7
+ and the following disclaimer.
8
+
9
+ (2) Redistributions in binary form must reproduce the above copyright notice, this list of conditions
10
+ and the following disclaimer in the documentation and/or other materials provided with the distribution.
11
+
12
+ (3) Neither the name of the copyright holder nor the names of any contributors may be used to endorse
13
+ or promote products derived from this software without specific prior written permission from the
14
+ respective party.
15
+
16
+ (4) Other than as required in clauses (1) and (2), distributions in any form of modifications or other
17
+ derivative works may not use the "OpenStudio" trademark, "OS", "os", or any other confusingly similar
18
+ designation without specific prior written permission from Alliance for Sustainable Energy, LLC.
19
+
20
+ THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED
21
+ WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
22
+ PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER, THE UNITED STATES GOVERNMENT,
23
+ OR ANY CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
24
+ DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,
25
+ OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
26
+ STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
27
+ SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
@@ -0,0 +1,80 @@
1
+
2
+
3
+ ###### (Automatically generated documentation)
4
+
5
+ # Cooling Coils Water Multiplier
6
+
7
+ ## Description
8
+ This is a general purpose measure to calibrate Water Cooling Coils with a Multiplier.
9
+
10
+ ## Modeler Description
11
+ It will be used for calibration of inlet water temperatures, inlet and outlet air temperatures and design flowrates. User can choose between a SINGLE coil or ALL the Coils.
12
+
13
+ ## Measure Type
14
+ ModelMeasure
15
+
16
+ ## Taxonomy
17
+
18
+
19
+ ## Arguments
20
+
21
+
22
+ ### Apply the Measure to a SINGLE Water Cooling Coil, ALL the Water Cooling Coils or NONE.
23
+
24
+ **Name:** coil,
25
+ **Type:** Choice,
26
+ **Units:** ,
27
+ **Required:** true,
28
+ **Model Dependent:** false
29
+
30
+ ### Multiplier for Design Water Flow Rate.
31
+ Multiplier for Design Water Flow Rate.
32
+ **Name:** design_water_flow_rate,
33
+ **Type:** Double,
34
+ **Units:** ,
35
+ **Required:** true,
36
+ **Model Dependent:** false
37
+
38
+ ### Multiplier for Design Air Flow Rate.
39
+ Multiplier for Design Air Flow Rate.
40
+ **Name:** design_air_flow_rate,
41
+ **Type:** Double,
42
+ **Units:** ,
43
+ **Required:** true,
44
+ **Model Dependent:** false
45
+
46
+ ### Multiplier for Inlet Water Temperature.
47
+ Multiplier for Inlet Water Temperature.
48
+ **Name:** design_inlet_water_temperature,
49
+ **Type:** Double,
50
+ **Units:** ,
51
+ **Required:** true,
52
+ **Model Dependent:** false
53
+
54
+ ### Multiplier for Inlet Air Temperature.
55
+ Multiplier for Inlet Air Temperature.
56
+ **Name:** design_inlet_air_temperature,
57
+ **Type:** Double,
58
+ **Units:** ,
59
+ **Required:** true,
60
+ **Model Dependent:** false
61
+
62
+ ### Multiplier for Outlet Air Temperature.
63
+ Multiplier for Outlet Air Temperature.
64
+ **Name:** design_outlet_air_temperature,
65
+ **Type:** Double,
66
+ **Units:** ,
67
+ **Required:** true,
68
+ **Model Dependent:** false
69
+
70
+ ### Multiplier for Inlet Air Humidity Ratio.
71
+ Multiplier for Inlet Air Humidity Ratio.
72
+ **Name:** design_inlet_air_humidity_ratio,
73
+ **Type:** Double,
74
+ **Units:** ,
75
+ **Required:** true,
76
+ **Model Dependent:** false
77
+
78
+
79
+
80
+
@@ -0,0 +1,42 @@
1
+ <%#= README.md.erb is used to auto-generate README.md. %>
2
+ <%#= To manually maintain README.md throw away README.md.erb and manually edit README.md %>
3
+ ###### (Automatically generated documentation)
4
+
5
+ # <%= name %>
6
+
7
+ ## Description
8
+ <%= description %>
9
+
10
+ ## Modeler Description
11
+ <%= modelerDescription %>
12
+
13
+ ## Measure Type
14
+ <%= measureType %>
15
+
16
+ ## Taxonomy
17
+ <%= taxonomy %>
18
+
19
+ ## Arguments
20
+
21
+ <% arguments.each do |argument| %>
22
+ ### <%= argument[:display_name] %>
23
+ <%= argument[:description] %>
24
+ **Name:** <%= argument[:name] %>,
25
+ **Type:** <%= argument[:type] %>,
26
+ **Units:** <%= argument[:units] %>,
27
+ **Required:** <%= argument[:required] %>,
28
+ **Model Dependent:** <%= argument[:model_dependent] %>
29
+ <% end %>
30
+
31
+ <% if arguments.size == 0 %>
32
+ <%= "This measure does not have any user arguments" %>
33
+ <% end %>
34
+
35
+ <% if outputs.size > 0 %>
36
+ ## Outputs
37
+ <% output_names = [] %>
38
+ <% outputs.each do |output| %>
39
+ <% output_names << output[:display_name] %>
40
+ <% end %>
41
+ <%= output_names.join(", ") %>
42
+ <% end %>
@@ -0,0 +1,324 @@
1
+ # *******************************************************************************
2
+ # OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC.
3
+ # All rights reserved.
4
+ # Redistribution and use in source and binary forms, with or without
5
+ # modification, are permitted provided that the following conditions are met:
6
+ #
7
+ # (1) Redistributions of source code must retain the above copyright notice,
8
+ # this list of conditions and the following disclaimer.
9
+ #
10
+ # (2) Redistributions in binary form must reproduce the above copyright notice,
11
+ # this list of conditions and the following disclaimer in the documentation
12
+ # and/or other materials provided with the distribution.
13
+ #
14
+ # (3) Neither the name of the copyright holder nor the names of any contributors
15
+ # may be used to endorse or promote products derived from this software without
16
+ # specific prior written permission from the respective party.
17
+ #
18
+ # (4) Other than as required in clauses (1) and (2), distributions in any form
19
+ # of modifications or other derivative works may not use the "OpenStudio"
20
+ # trademark, "OS", "os", or any other confusingly similar designation without
21
+ # specific prior written permission from Alliance for Sustainable Energy, LLC.
22
+ #
23
+ # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS
24
+ # "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
25
+ # THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
26
+ # ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE
27
+ # UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF
28
+ # THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
29
+ # EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT
30
+ # OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
31
+ # INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
32
+ # STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
33
+ # OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
34
+ # *******************************************************************************
35
+
36
+ # start the measure
37
+ class CoilCoolingWaterMultiplier < OpenStudio::Measure::ModelMeasure
38
+ # human readable name
39
+ def name
40
+ 'Cooling Coils Water Multiplier'
41
+ end
42
+
43
+ # human readable description
44
+ def description
45
+ 'This is a general purpose measure to calibrate Water Cooling Coils with a Multiplier.'
46
+ end
47
+
48
+ # human readable description of modeling approach
49
+ def modeler_description
50
+ 'It will be used for calibration of inlet water temperatures, inlet and outlet air temperatures and design flowrates. User can choose between a SINGLE coil or ALL the Coils.'
51
+ end
52
+
53
+ def change_name(object, design_water_flow_rate, design_air_flow_rate, design_inlet_water_temperature, design_inlet_air_temperature, design_outlet_air_temperature, design_inlet_air_humidity_ratio)
54
+ nameString = object.name.get.to_s
55
+ if design_water_flow_rate != 1.0
56
+ nameString += " #{design_water_flow_rate.round(2)}x waterDFR"
57
+ end
58
+ if design_air_flow_rate != 1.0
59
+ nameString += " #{design_air_flow_rate.round(2)}x airDFR"
60
+ end
61
+ if design_inlet_water_temperature != 1.0
62
+ nameString += " #{design_inlet_water_temperature.round(2)}x DIWT"
63
+ end
64
+ if design_inlet_air_temperature != 1.0
65
+ nameString += " #{design_inlet_air_temperature.round(2)}x DIAT"
66
+ end
67
+ if design_outlet_air_temperature != 1.0
68
+ nameString += " #{design_outlet_air_temperature.round(2)}x DOAT"
69
+ end
70
+ if design_inlet_air_humidity_ratio != 1.0
71
+ nameString += " #{design_inlet_air_humidity_ratio.round(2)}x DIAHR"
72
+ end
73
+ object.setName(nameString)
74
+ end
75
+
76
+ def check_multiplier(runner, multiplier)
77
+ if multiplier < 0
78
+ runner.registerError("Multiplier #{multiplier} cannot be negative.")
79
+ false
80
+ end
81
+ end
82
+
83
+ # define the arguments that the user will input
84
+ def arguments(model)
85
+ args = OpenStudio::Measure::OSArgumentVector.new
86
+
87
+ # populate choice argument for constructions that are applied to surfaces in the model
88
+ loop_handles = OpenStudio::StringVector.new
89
+ loop_display_names = OpenStudio::StringVector.new
90
+
91
+ # putting air loops and names into hash
92
+ loop_args = model.getAirLoopHVACs
93
+ loop_args_hash = {}
94
+ loop_args.each do |loop_arg|
95
+ loop_args_hash[loop_arg.name.to_s] = loop_arg
96
+ end
97
+
98
+ # looping through sorted hash of air loops
99
+ loop_args_hash.sort.map do |_key, value|
100
+ show_loop = false
101
+ components = value.supplyComponents
102
+ components.each do |component|
103
+ next if component.to_CoilCoolingWater.empty?
104
+ show_loop = true
105
+ loop_handles << component.handle.to_s
106
+ loop_display_names << component.name.to_s
107
+ end
108
+
109
+ # if loop as object of correct type then add to hash.
110
+ # if show_loop == true
111
+ # loop_handles << value.handle.to_s
112
+ # loop_display_names << key
113
+ # end
114
+ end
115
+
116
+ # add building to string vector with space type
117
+ building = model.getBuilding
118
+ loop_handles << building.handle.to_s
119
+ loop_display_names << '*All Water Cooling Coils*'
120
+ loop_handles << '0'
121
+ loop_display_names << '*None*'
122
+
123
+ # make a choice argument for space type
124
+ coil_arg = OpenStudio::Measure::OSArgument.makeChoiceArgument('coil', loop_handles, loop_display_names)
125
+ coil_arg.setDisplayName('Apply the Measure to a SINGLE Water Cooling Coil, ALL the Water Cooling Coils or NONE.')
126
+ coil_arg.setDefaultValue('*All Water Cooling Coils*') # if no space type is chosen this will run on the entire building
127
+ args << coil_arg
128
+
129
+ # design_water_flow_rate
130
+ design_water_flow_rate = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_water_flow_rate', true)
131
+ design_water_flow_rate.setDisplayName('Multiplier for Design Water Flow Rate.')
132
+ design_water_flow_rate.setDescription('Multiplier for Design Water Flow Rate.')
133
+ design_water_flow_rate.setDefaultValue(1.0)
134
+ args << design_water_flow_rate
135
+
136
+ # design_air_flow_rate
137
+ design_air_flow_rate = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_air_flow_rate', true)
138
+ design_air_flow_rate.setDisplayName('Multiplier for Design Air Flow Rate.')
139
+ design_air_flow_rate.setDescription('Multiplier for Design Air Flow Rate.')
140
+ design_air_flow_rate.setDefaultValue(1.0)
141
+ args << design_air_flow_rate
142
+
143
+ # design_inlet_water_temperature
144
+ design_inlet_water_temperature = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_inlet_water_temperature', true)
145
+ design_inlet_water_temperature.setDisplayName('Multiplier for Inlet Water Temperature.')
146
+ design_inlet_water_temperature.setDescription('Multiplier for Inlet Water Temperature.')
147
+ design_inlet_water_temperature.setDefaultValue(1.0)
148
+ args << design_inlet_water_temperature
149
+
150
+ # design_inlet_air_temperature
151
+ design_inlet_air_temperature = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_inlet_air_temperature', true)
152
+ design_inlet_air_temperature.setDisplayName('Multiplier for Inlet Air Temperature.')
153
+ design_inlet_air_temperature.setDescription('Multiplier for Inlet Air Temperature.')
154
+ design_inlet_air_temperature.setDefaultValue(1.0)
155
+ args << design_inlet_air_temperature
156
+
157
+ # design_outlet_air_temperature
158
+ design_outlet_air_temperature = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_outlet_air_temperature', true)
159
+ design_outlet_air_temperature.setDisplayName('Multiplier for Outlet Air Temperature.')
160
+ design_outlet_air_temperature.setDescription('Multiplier for Outlet Air Temperature.')
161
+ design_outlet_air_temperature.setDefaultValue(1.0)
162
+ args << design_outlet_air_temperature
163
+
164
+ # design_inlet_air_humidity_ratio
165
+ design_inlet_air_humidity_ratio = OpenStudio::Measure::OSArgument.makeDoubleArgument('design_inlet_air_humidity_ratio', true)
166
+ design_inlet_air_humidity_ratio.setDisplayName('Multiplier for Inlet Air Humidity Ratio.')
167
+ design_inlet_air_humidity_ratio.setDescription('Multiplier for Inlet Air Humidity Ratio.')
168
+ design_inlet_air_humidity_ratio.setDefaultValue(1.0)
169
+ args << design_inlet_air_humidity_ratio
170
+
171
+ args
172
+ end
173
+
174
+ # define what happens when the measure is run
175
+ def run(model, runner, user_arguments)
176
+ super(model, runner, user_arguments)
177
+
178
+ # use the built-in error checking
179
+ unless runner.validateUserArguments(arguments(model), user_arguments)
180
+ return false
181
+ end
182
+
183
+ # assign the user inputs to variables
184
+ coil_object = runner.getOptionalWorkspaceObjectChoiceValue('coil', user_arguments, model)
185
+ coil_handle = runner.getStringArgumentValue('coil', user_arguments)
186
+
187
+ design_air_flow_rate = runner.getDoubleArgumentValue('design_air_flow_rate', user_arguments)
188
+ check_multiplier(runner, design_air_flow_rate)
189
+ design_water_flow_rate = runner.getDoubleArgumentValue('design_water_flow_rate', user_arguments)
190
+ check_multiplier(runner, design_water_flow_rate)
191
+ design_inlet_air_temperature = runner.getDoubleArgumentValue('design_inlet_air_temperature', user_arguments)
192
+ check_multiplier(runner, design_inlet_air_temperature)
193
+ design_outlet_air_temperature = runner.getDoubleArgumentValue('design_outlet_air_temperature', user_arguments)
194
+ check_multiplier(runner, design_outlet_air_temperature)
195
+ design_inlet_air_humidity_ratio = runner.getDoubleArgumentValue('design_inlet_air_humidity_ratio', user_arguments)
196
+ check_multiplier(runner, design_inlet_air_humidity_ratio)
197
+ design_inlet_water_temperature = runner.getDoubleArgumentValue('design_inlet_water_temperature', user_arguments)
198
+ check_multiplier(runner, design_inlet_water_temperature)
199
+
200
+ # find objects to change
201
+ coils = []
202
+ building = model.getBuilding
203
+ building_handle = building.handle.to_s
204
+ runner.registerInfo("coil_handle: #{coil_handle}")
205
+ # setup coils
206
+ if coil_handle == building_handle
207
+ # Use ALL coils
208
+ runner.registerInfo('Applying change to ALL Coils')
209
+ loops = model.getAirLoopHVACs
210
+ # loop through air loops
211
+ loops.each do |loop|
212
+ supply_components = loop.supplyComponents
213
+ # find coils on loops
214
+ supply_components.each do |supply_component|
215
+ unless supply_component.to_CoilCoolingWater.empty?
216
+ coils << supply_component.to_CoilCoolingWater.get
217
+ end
218
+ end
219
+ end
220
+ elsif coil_handle == 0.to_s
221
+ # coils set to NONE so do nothing
222
+ runner.registerInfo('Applying change to NONE Coils')
223
+ elsif !coil_handle.empty?
224
+ # Single coil handle found, check if object is good
225
+ if !coil_object.get.to_CoilCoolingWater.empty?
226
+ runner.registerInfo("Applying change to #{coil_object.get.name} coil")
227
+ coils << coil_object.get.to_CoilCoolingWater.get
228
+ else
229
+ runner.registerError("coil with handle #{coil_handle} could not be found.")
230
+ end
231
+ else
232
+ runner.registerError('coil handle is empty.')
233
+ return false
234
+ end
235
+
236
+ # report initial condition of model
237
+ runner.registerInitialCondition("Coils to change: #{coils.size}")
238
+ runner.registerInfo("Coils to change: #{coils.size}")
239
+ altered_coils = []
240
+ altered_capacity = []
241
+ altered_coilefficiency = []
242
+ # loop through coils
243
+ coils.each do |coil|
244
+ altered_coil = false
245
+ # design_air_flow_rate
246
+ if design_air_flow_rate != 1.0
247
+ if coil.designAirFlowRate.is_initialized
248
+ runner.registerInfo("Applying designAirFlowRate #{design_air_flow_rate}x multiplier to #{coil.name.get}.")
249
+ coil.setDesignAirFlowRate(coil.designAirFlowRate.get * design_air_flow_rate)
250
+ altered_capacity << coil.handle.to_s
251
+ altered_coil = true
252
+ end
253
+ end
254
+
255
+ # modify design_water_flow_rate
256
+ if design_water_flow_rate != 1.0
257
+ if coil.designWaterFlowRate.is_initialized
258
+ runner.registerInfo("Applying designWaterFlowRate #{design_water_flow_rate}x multiplier to #{coil.name.get}.")
259
+ coil.setDesignWaterFlowRate(coil.designWaterFlowRate.get * design_water_flow_rate)
260
+ altered_coilefficiency << coil.handle.to_s
261
+ altered_coil = true
262
+ end
263
+ end
264
+
265
+ # design_inlet_air_temperature
266
+ if design_inlet_air_temperature != 1.0
267
+ if coil.designInletAirTemperature.is_initialized
268
+ runner.registerInfo("Applying designInletAirTemperature #{design_inlet_air_temperature}x multiplier to #{coil.name.get}.")
269
+ coil.setDesignInletAirTemperature(coil.designInletAirTemperature.get * design_inlet_air_temperature)
270
+ altered_capacity << coil.handle.to_s
271
+ altered_coil = true
272
+ end
273
+ end
274
+
275
+ # modify design_inlet_water_temperature
276
+ if design_inlet_water_temperature != 1.0
277
+ if coil.designInletWaterTemperature.is_initialized
278
+ runner.registerInfo("Applying designInletWaterTemperature #{design_inlet_water_temperature}x multiplier to #{coil.name.get}.")
279
+ coil.setDesignInletWaterTemperature(coil.designInletWaterTemperature.get * design_inlet_water_temperature)
280
+ altered_coilefficiency << coil.handle.to_s
281
+ altered_coil = true
282
+ end
283
+ end
284
+
285
+ # design_inlet_air_humidity_ratio
286
+ if design_inlet_air_humidity_ratio != 1.0
287
+ if coil.designInletAirHumidityRatio.is_initialized
288
+ runner.registerInfo("Applying designInletAirHumidityRatio #{design_inlet_air_humidity_ratio}x multiplier to #{coil.name.get}.")
289
+ coil.setDesignInletAirHumidityRatio(coil.designInletAirHumidityRatio.get * design_inlet_air_humidity_ratio)
290
+ altered_capacity << coil.handle.to_s
291
+ altered_coil = true
292
+ end
293
+ end
294
+
295
+ # modify design_outlet_air_temperature
296
+ if design_outlet_air_temperature != 1.0
297
+ if coil.designOutletAirTemperature.is_initialized
298
+ runner.registerInfo("Applying designOutletAirTemperature #{design_outlet_air_temperature}x multiplier to #{coil.name.get}.")
299
+ coil.setDesignOutletAirTemperature(coil.designOutletAirTemperature.get * design_outlet_air_temperature)
300
+ altered_coilefficiency << coil.handle.to_s
301
+ altered_coil = true
302
+ end
303
+ end
304
+ next unless altered_coil
305
+ altered_coils << coil.handle.to_s
306
+ change_name(coil, design_water_flow_rate, design_air_flow_rate, design_inlet_water_temperature, design_inlet_air_temperature, design_outlet_air_temperature, design_inlet_air_humidity_ratio)
307
+ runner.registerInfo("coil name changed to: #{coil.name.get}")
308
+ end # end coil loop
309
+
310
+ # na if nothing in model to look at
311
+ if altered_coils.empty?
312
+ runner.registerAsNotApplicable('No Coils were altered in the model')
313
+ return true
314
+ end
315
+
316
+ # report final condition of model
317
+ runner.registerFinalCondition("#{altered_coils.size} Coils objects were altered.")
318
+
319
+ true
320
+ end
321
+ end
322
+
323
+ # register the measure to be used by the application
324
+ CoilCoolingWaterMultiplier.new.registerWithApplication