distgridforge 0.3.0__py3-none-any.whl
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- distgridforge-0.3.0.dist-info/METADATA +266 -0
- distgridforge-0.3.0.dist-info/RECORD +38 -0
- distgridforge-0.3.0.dist-info/WHEEL +5 -0
- distgridforge-0.3.0.dist-info/licenses/LICENCE.txt +21 -0
- distgridforge-0.3.0.dist-info/top_level.txt +1 -0
- gridforge/__init__.py +32 -0
- gridforge/case_study/config.py +158 -0
- gridforge/case_study/dickert_lv_network_script.py +109 -0
- gridforge/case_study/mv_lv_feeder.py +314 -0
- gridforge/case_study/simbench_network_test_case.py +168 -0
- gridforge/core/__init__.py +0 -0
- gridforge/core/constraints.py +421 -0
- gridforge/core/cost_model.py +363 -0
- gridforge/core/grid_enhancement.py +1932 -0
- gridforge/core/power_flow.py +1146 -0
- gridforge/core/strategy.py +297 -0
- gridforge/engines/__init__.py +0 -0
- gridforge/engines/gridlabd_engine.py +527 -0
- gridforge/engines/opendss_engine.py +885 -0
- gridforge/engines/pandapower_engine.py +3766 -0
- gridforge/engines/roseau_engine.py +1234 -0
- gridforge/examples/__init__.py +0 -0
- gridforge/examples/quick_start.py +85 -0
- gridforge/main.py +0 -0
- gridforge/strategies/__init__.py +0 -0
- gridforge/strategies/flexibility.py +1476 -0
- gridforge/strategies/line_upgrade.py +1846 -0
- gridforge/strategies/path_to_source.py +596 -0
- gridforge/strategies/sizing.py +210 -0
- gridforge/strategies/step_check.py +183 -0
- gridforge/strategies/tap_change.py +267 -0
- gridforge/strategies/transformer_upgrade.py +622 -0
- gridforge/utils/__init__.py +0 -0
- gridforge/utils/config.py +55 -0
- gridforge/utils/interactive_plot.py +700 -0
- gridforge/utils/logging.py +86 -0
- gridforge/utils/plot.py +1078 -0
- gridforge/utils/reporting.py +0 -0
|
@@ -0,0 +1,314 @@
|
|
|
1
|
+
import logging
|
|
2
|
+
import multiprocessing
|
|
3
|
+
import sys
|
|
4
|
+
import traceback
|
|
5
|
+
import warnings
|
|
6
|
+
from pathlib import Path
|
|
7
|
+
from typing import Any
|
|
8
|
+
|
|
9
|
+
import pandapower as pp
|
|
10
|
+
from tqdm import tqdm
|
|
11
|
+
|
|
12
|
+
from gridforge import PowerFlowNotConverged, data_path
|
|
13
|
+
from gridforge.case_study.config import MV_LV_FEEDER
|
|
14
|
+
from gridforge.core.cost_model import CostModel
|
|
15
|
+
from gridforge.core.grid_enhancement import (
|
|
16
|
+
EnhancementStrategyRegistry,
|
|
17
|
+
GridEnhancementAlgorithm,
|
|
18
|
+
)
|
|
19
|
+
from gridforge.engines.pandapower_engine import PandaPowerEngine
|
|
20
|
+
from gridforge.strategies.flexibility import FlexibilityStrategy
|
|
21
|
+
from gridforge.strategies.line_upgrade import LineUpgradeStrategy
|
|
22
|
+
from gridforge.strategies.transformer_upgrade import TransformerUpgradeStrategy
|
|
23
|
+
from gridforge.utils.interactive_plot import create_enhancement_visualisation
|
|
24
|
+
from gridforge.utils.logging import setup_logging
|
|
25
|
+
|
|
26
|
+
warnings.filterwarnings("ignore")
|
|
27
|
+
|
|
28
|
+
setup_logging(logging.INFO)
|
|
29
|
+
logger = logging.getLogger(__name__)
|
|
30
|
+
|
|
31
|
+
|
|
32
|
+
def make_shared_names_unique(network, label=""):
|
|
33
|
+
"""
|
|
34
|
+
Rename the loads and static generators that share a name with another of their
|
|
35
|
+
table, which `PandaPowerEngine.check_names` refuses.
|
|
36
|
+
|
|
37
|
+
Of the elements of one name, the first in the order of the table keeps it, and the
|
|
38
|
+
others are given it followed by ``_2``, ``_3``..., in that order, skipping any
|
|
39
|
+
name already in the table. The renamed elements are logged at warning level, with
|
|
40
|
+
`label` (the feeder) in front. A network without shared names is left as it is.
|
|
41
|
+
|
|
42
|
+
Of the 150 feeders of the case study, only ``84_MVFeeder4049`` has some: 4 names
|
|
43
|
+
on 2 loads each, all at the same bus, whose second load is renamed. As the case
|
|
44
|
+
study gives every load the same flexibility, no decision changes.
|
|
45
|
+
|
|
46
|
+
Returns:
|
|
47
|
+
dict[str, dict[int, tuple[str, str]]]: For each table renamed in, the index of
|
|
48
|
+
each renamed element with its former and its new name.
|
|
49
|
+
"""
|
|
50
|
+
renamed: dict[str, dict[int, tuple[str, str]]] = {}
|
|
51
|
+
for element in ("load", "sgen"):
|
|
52
|
+
table = getattr(network, element, None)
|
|
53
|
+
if table is None or table.empty or "name" not in table.columns:
|
|
54
|
+
continue
|
|
55
|
+
names = table["name"]
|
|
56
|
+
present = names.notna() & (names != "")
|
|
57
|
+
repeated = names[present & names.duplicated(keep="first")]
|
|
58
|
+
if repeated.empty:
|
|
59
|
+
continue
|
|
60
|
+
taken = set(names[present])
|
|
61
|
+
changes = {}
|
|
62
|
+
for index, name in repeated.items():
|
|
63
|
+
k = 2
|
|
64
|
+
while f"{name}_{k}" in taken:
|
|
65
|
+
k += 1
|
|
66
|
+
new = f"{name}_{k}"
|
|
67
|
+
taken.add(new)
|
|
68
|
+
changes[index] = (name, new)
|
|
69
|
+
table.loc[list(changes), "name"] = [new for _, new in changes.values()]
|
|
70
|
+
renamed[element] = changes
|
|
71
|
+
logger.warning(
|
|
72
|
+
f"{label}: {len(changes)} {element} name(s) shared with another of the "
|
|
73
|
+
"table made unique: "
|
|
74
|
+
+ ", ".join(
|
|
75
|
+
f"{index} {old!r} -> {new!r}" for index, (old, new) in changes.items()
|
|
76
|
+
)
|
|
77
|
+
)
|
|
78
|
+
return renamed
|
|
79
|
+
|
|
80
|
+
|
|
81
|
+
def load_network(network_path, load_factor):
|
|
82
|
+
"""
|
|
83
|
+
Load a pandapower network and prepare it for testing.
|
|
84
|
+
|
|
85
|
+
Loads and static generators that share a name are renamed first
|
|
86
|
+
(`make_shared_names_unique`), as the engine refuses them.
|
|
87
|
+
"""
|
|
88
|
+
# Initialize the engine
|
|
89
|
+
pf_engine = PandaPowerEngine()
|
|
90
|
+
|
|
91
|
+
# Load the network
|
|
92
|
+
network = pp.from_json(network_path)
|
|
93
|
+
make_shared_names_unique(network, Path(network_path).stem)
|
|
94
|
+
|
|
95
|
+
# Set the network in the engine
|
|
96
|
+
pf_engine.network = network
|
|
97
|
+
|
|
98
|
+
# Modify the network to create some violations
|
|
99
|
+
# Increase load at some buses to create voltage violations
|
|
100
|
+
if hasattr(network, "load"):
|
|
101
|
+
network.load["p_mw"] *= load_factor
|
|
102
|
+
network.load["q_mvar"] *= load_factor
|
|
103
|
+
|
|
104
|
+
if hasattr(network, "asymmetric_load"):
|
|
105
|
+
for col in ["p_a_mw", "p_b_mw", "p_c_mw", "q_a_mvar", "q_b_mvar", "q_c_mvar"]:
|
|
106
|
+
if col in network.asymmetric_load.columns:
|
|
107
|
+
network.asymmetric_load[col] *= load_factor
|
|
108
|
+
|
|
109
|
+
return pf_engine
|
|
110
|
+
|
|
111
|
+
|
|
112
|
+
def create_strategy_registry(with_flex=True):
|
|
113
|
+
"""Create a strategy registry with voltage and loading strategies."""
|
|
114
|
+
registry = EnhancementStrategyRegistry()
|
|
115
|
+
|
|
116
|
+
# Add loading strategies
|
|
117
|
+
line_upgrade_strategy = LineUpgradeStrategy(
|
|
118
|
+
line_types=MV_LV_FEEDER.line_types,
|
|
119
|
+
max_iterations=MV_LV_FEEDER.line_upgrade_max_iterations,
|
|
120
|
+
min_voltage_sensitivity=MV_LV_FEEDER.line_upgrade_min_voltage_sensitivity,
|
|
121
|
+
)
|
|
122
|
+
registry.register_strategy(line_upgrade_strategy)
|
|
123
|
+
|
|
124
|
+
# Add custom transformer upgrade strategy
|
|
125
|
+
transformer_upgrade_strategy = TransformerUpgradeStrategy(MV_LV_FEEDER.trafo_types)
|
|
126
|
+
registry.register_strategy(transformer_upgrade_strategy)
|
|
127
|
+
if with_flex:
|
|
128
|
+
registry.register_strategy(
|
|
129
|
+
FlexibilityStrategy(n_activation=MV_LV_FEEDER.flexibility_n_activation)
|
|
130
|
+
)
|
|
131
|
+
|
|
132
|
+
return registry
|
|
133
|
+
|
|
134
|
+
|
|
135
|
+
def create_cost_model():
|
|
136
|
+
"""Create a cost model for evaluating strategies."""
|
|
137
|
+
return CostModel(MV_LV_FEEDER.unit_costs)
|
|
138
|
+
|
|
139
|
+
|
|
140
|
+
def run_grid_enhancement(
|
|
141
|
+
network_path,
|
|
142
|
+
strategy_registry,
|
|
143
|
+
cost_model,
|
|
144
|
+
load_factor,
|
|
145
|
+
flexibility_pct,
|
|
146
|
+
output_dir,
|
|
147
|
+
):
|
|
148
|
+
"""
|
|
149
|
+
Helper function to run grid enhancement tests with the example network.
|
|
150
|
+
|
|
151
|
+
Args:
|
|
152
|
+
network_path: Path to the network json file
|
|
153
|
+
strategy_registry: Registry of enhancement strategies
|
|
154
|
+
cost_model: Cost model for evaluating strategies
|
|
155
|
+
load_factor: Factor to increase load
|
|
156
|
+
flexibility_pct: Percentage of flexibility
|
|
157
|
+
output_dir: Directory to save results
|
|
158
|
+
"""
|
|
159
|
+
power_flow_engine = load_network(network_path, load_factor)
|
|
160
|
+
output_path = (
|
|
161
|
+
output_dir / f"{network_path.stem}_flex_{int(flexibility_pct)}_pct.html"
|
|
162
|
+
)
|
|
163
|
+
return enhance_network(
|
|
164
|
+
power_flow_engine, strategy_registry, cost_model, flexibility_pct, output_path
|
|
165
|
+
)
|
|
166
|
+
|
|
167
|
+
|
|
168
|
+
def enhance_network(
|
|
169
|
+
power_flow_engine, strategy_registry, cost_model, flexibility_pct, output_path
|
|
170
|
+
):
|
|
171
|
+
"""
|
|
172
|
+
Run the enhancement algorithm on a loaded network and write its visualisation.
|
|
173
|
+
|
|
174
|
+
Args:
|
|
175
|
+
power_flow_engine: Engine holding the network, as `load_network` returns it
|
|
176
|
+
strategy_registry: Registry of enhancement strategies
|
|
177
|
+
cost_model: Cost model for evaluating strategies
|
|
178
|
+
flexibility_pct: Percentage of flexibility of the loads
|
|
179
|
+
output_path: Path of the HTML visualisation of the run
|
|
180
|
+
"""
|
|
181
|
+
if hasattr(power_flow_engine.network, "load"):
|
|
182
|
+
power_flow_engine.flexibility_settings["load"] = {
|
|
183
|
+
name: flexibility_pct
|
|
184
|
+
for name in power_flow_engine.network.load["name"].tolist()
|
|
185
|
+
}
|
|
186
|
+
|
|
187
|
+
# Configure the algorithm
|
|
188
|
+
algorithm = GridEnhancementAlgorithm(
|
|
189
|
+
power_flow_engine=power_flow_engine,
|
|
190
|
+
strategy_registry=strategy_registry,
|
|
191
|
+
cost_model=cost_model,
|
|
192
|
+
max_iterations=MV_LV_FEEDER.algorithm_max_iterations,
|
|
193
|
+
)
|
|
194
|
+
# Run the grid enhancement algorithm
|
|
195
|
+
success, results = algorithm.run()
|
|
196
|
+
|
|
197
|
+
create_enhancement_visualisation(algorithm, str(output_path))
|
|
198
|
+
return results
|
|
199
|
+
|
|
200
|
+
|
|
201
|
+
def process_single_network(args) -> dict[str, Any]:
|
|
202
|
+
"""Run one network/flexibility combination, reporting success or failure.
|
|
203
|
+
|
|
204
|
+
Runs in a worker process, so failures can't just propagate to the caller — instead
|
|
205
|
+
of being logged and silently dropped, they're returned so the caller can collect
|
|
206
|
+
and report every failure once all networks have been processed.
|
|
207
|
+
|
|
208
|
+
The record also tells whether the power flow diverged: either along the way (the run
|
|
209
|
+
is then still a success, with a partial or complete solution) or on the initial
|
|
210
|
+
power flow (the run is then a failure, as there is no solution at all).
|
|
211
|
+
"""
|
|
212
|
+
network_path, load_factor, flexibility_pct, output_dir = args
|
|
213
|
+
# Re-create registry and cost model for each process to avoid shared state issues
|
|
214
|
+
with_flex = flexibility_pct > 0
|
|
215
|
+
strategy_registry = create_strategy_registry(with_flex)
|
|
216
|
+
cost_model = create_cost_model()
|
|
217
|
+
|
|
218
|
+
result = {
|
|
219
|
+
"network": network_path.name,
|
|
220
|
+
"flexibility_pct": flexibility_pct,
|
|
221
|
+
"success": False,
|
|
222
|
+
"diverged": False,
|
|
223
|
+
"error": None,
|
|
224
|
+
}
|
|
225
|
+
try:
|
|
226
|
+
results = run_grid_enhancement(
|
|
227
|
+
network_path,
|
|
228
|
+
strategy_registry,
|
|
229
|
+
cost_model,
|
|
230
|
+
load_factor,
|
|
231
|
+
flexibility_pct,
|
|
232
|
+
output_dir,
|
|
233
|
+
)
|
|
234
|
+
result["success"] = True
|
|
235
|
+
result["diverged"] = results["diverged"]
|
|
236
|
+
except Exception as exc:
|
|
237
|
+
error = traceback.format_exc()
|
|
238
|
+
logging.error(f"Error processing {network_path.name}:\n{error}")
|
|
239
|
+
result["error"] = error
|
|
240
|
+
result["diverged"] = isinstance(exc, PowerFlowNotConverged)
|
|
241
|
+
return result
|
|
242
|
+
|
|
243
|
+
|
|
244
|
+
if __name__ == "__main__":
|
|
245
|
+
# Create output directory
|
|
246
|
+
output_dir = Path("results")
|
|
247
|
+
output_dir.mkdir(exist_ok=True)
|
|
248
|
+
|
|
249
|
+
# Get all network files
|
|
250
|
+
network_files = sorted(data_path["pandapower"].glob("*.json"))
|
|
251
|
+
if not network_files:
|
|
252
|
+
# The feeder files are not part of the installed package
|
|
253
|
+
raise FileNotFoundError(
|
|
254
|
+
f"No feeder file (*.json) in {data_path['pandapower']}. The case study needs "
|
|
255
|
+
f"the feeder data of the repository: run it from a clone of gridforge."
|
|
256
|
+
)
|
|
257
|
+
|
|
258
|
+
# Parameters
|
|
259
|
+
load_factor = 2.5
|
|
260
|
+
flex_scenarios = [0.0, 30.0]
|
|
261
|
+
# flex_scenarios = [0.]
|
|
262
|
+
|
|
263
|
+
failures: list[dict[str, Any]] = []
|
|
264
|
+
diverged_runs: list[dict[str, Any]] = []
|
|
265
|
+
|
|
266
|
+
for flexibility_pct in flex_scenarios:
|
|
267
|
+
logging.info(f"--- Running scenario with {flexibility_pct}% flexibility ---")
|
|
268
|
+
|
|
269
|
+
# Prepare arguments for parallel execution
|
|
270
|
+
args_list = [
|
|
271
|
+
(f, load_factor, flexibility_pct, output_dir) for f in network_files
|
|
272
|
+
]
|
|
273
|
+
|
|
274
|
+
# Run in parallel
|
|
275
|
+
num_processes = multiprocessing.cpu_count()
|
|
276
|
+
logging.info(
|
|
277
|
+
f"Starting parallel processing with {num_processes} processes for {len(network_files)} networks."
|
|
278
|
+
)
|
|
279
|
+
|
|
280
|
+
with multiprocessing.Pool(processes=num_processes) as pool:
|
|
281
|
+
# Use tqdm for progress bar by wrapping pool.imap_unordered
|
|
282
|
+
scenario_results = list(
|
|
283
|
+
tqdm(
|
|
284
|
+
pool.imap_unordered(process_single_network, args_list),
|
|
285
|
+
total=len(args_list),
|
|
286
|
+
)
|
|
287
|
+
)
|
|
288
|
+
|
|
289
|
+
failures.extend(r for r in scenario_results if not r["success"])
|
|
290
|
+
diverged_runs.extend(r for r in scenario_results if r["diverged"])
|
|
291
|
+
|
|
292
|
+
total_runs = len(network_files) * len(flex_scenarios)
|
|
293
|
+
if diverged_runs:
|
|
294
|
+
logging.warning(
|
|
295
|
+
f"{len(diverged_runs)}/{total_runs} network run(s) hit a power flow divergence:"
|
|
296
|
+
)
|
|
297
|
+
for run in diverged_runs:
|
|
298
|
+
outcome = (
|
|
299
|
+
"initial power flow, no result"
|
|
300
|
+
if not run["success"]
|
|
301
|
+
else "strategy undone, run continued"
|
|
302
|
+
)
|
|
303
|
+
logging.warning(
|
|
304
|
+
f" - {run['network']} (flexibility={run['flexibility_pct']}%): {outcome}"
|
|
305
|
+
)
|
|
306
|
+
if failures:
|
|
307
|
+
logging.error(f"{len(failures)}/{total_runs} network run(s) failed:")
|
|
308
|
+
for failure in failures:
|
|
309
|
+
logging.error(
|
|
310
|
+
f" - {failure['network']} (flexibility={failure['flexibility_pct']}%)"
|
|
311
|
+
)
|
|
312
|
+
sys.exit(1)
|
|
313
|
+
else:
|
|
314
|
+
logging.info(f"All {total_runs} network runs completed successfully.")
|
|
@@ -0,0 +1,168 @@
|
|
|
1
|
+
import logging
|
|
2
|
+
|
|
3
|
+
import networkx as nx
|
|
4
|
+
import pandapower as pp
|
|
5
|
+
import pandas as pd
|
|
6
|
+
import simbench as sb
|
|
7
|
+
|
|
8
|
+
from gridforge.case_study.config import SIMBENCH
|
|
9
|
+
from gridforge.core.cost_model import CostModel
|
|
10
|
+
from gridforge.core.grid_enhancement import (
|
|
11
|
+
EnhancementStrategyRegistry,
|
|
12
|
+
GridEnhancementAlgorithm,
|
|
13
|
+
)
|
|
14
|
+
from gridforge.engines.pandapower_engine import PandaPowerEngine
|
|
15
|
+
from gridforge.strategies.flexibility import FlexibilityStrategy
|
|
16
|
+
from gridforge.strategies.line_upgrade import LineUpgradeStrategy
|
|
17
|
+
from gridforge.strategies.tap_change import TapChangeStrategy
|
|
18
|
+
from gridforge.strategies.transformer_upgrade import TransformerUpgradeStrategy
|
|
19
|
+
from gridforge.utils.logging import setup_logging
|
|
20
|
+
|
|
21
|
+
setup_logging(logging.INFO)
|
|
22
|
+
|
|
23
|
+
|
|
24
|
+
def import_network():
|
|
25
|
+
sb_code1 = "1-LV-rural2--0-sw"
|
|
26
|
+
net = sb.get_simbench_net(sb_code1)
|
|
27
|
+
net["trafo"]["tap_changer_type"] = "Ratio"
|
|
28
|
+
print(net.loadcases)
|
|
29
|
+
return net
|
|
30
|
+
|
|
31
|
+
|
|
32
|
+
def get_downstream_buses(net, target_bus):
|
|
33
|
+
# 1. Find the root of the radial network (the slack bus / external grid)
|
|
34
|
+
# Assuming there is only one external grid for this radial network
|
|
35
|
+
slack_bus = net.ext_grid.bus.values[0]
|
|
36
|
+
|
|
37
|
+
# 2. Convert the pandapower network into a networkx graph
|
|
38
|
+
# respect_switches=True ensures open switches don't create false paths
|
|
39
|
+
mg = pp.topology.create_nxgraph(net, respect_switches=True)
|
|
40
|
+
|
|
41
|
+
# 3. Create a directed tree originating from the slack bus
|
|
42
|
+
# This automatically gives directionality flowing away from the source
|
|
43
|
+
directed_tree = nx.bfs_tree(mg, source=slack_bus)
|
|
44
|
+
|
|
45
|
+
# 4. Find all downstream buses (descendants in the directed tree)
|
|
46
|
+
# nx.descendants returns a set of nodes, we convert it to a list
|
|
47
|
+
downstream_buses = list(nx.descendants(directed_tree, target_bus))
|
|
48
|
+
|
|
49
|
+
return downstream_buses
|
|
50
|
+
|
|
51
|
+
|
|
52
|
+
def apply_load_scaling(net, scale_factor):
|
|
53
|
+
net["load"]["p_mw"] *= scale_factor
|
|
54
|
+
net["load"]["q_mvar"] *= scale_factor
|
|
55
|
+
|
|
56
|
+
|
|
57
|
+
def apply_absolute_values(net, absolute_values_dict, case_or_time_step):
|
|
58
|
+
for elm_param in absolute_values_dict.keys():
|
|
59
|
+
if absolute_values_dict[elm_param].shape[1]:
|
|
60
|
+
elm = elm_param[0]
|
|
61
|
+
param = elm_param[1]
|
|
62
|
+
net[elm].loc[:, param] = absolute_values_dict[elm_param].loc[
|
|
63
|
+
case_or_time_step
|
|
64
|
+
]
|
|
65
|
+
|
|
66
|
+
|
|
67
|
+
def create_case_study(load_scale=1.5, flexibility_pct=10.0):
|
|
68
|
+
net = import_network()
|
|
69
|
+
loadcases = sb.get_absolute_values(net, profiles_instead_of_study_cases=False)
|
|
70
|
+
apply_absolute_values(net, loadcases, "hL")
|
|
71
|
+
apply_load_scaling(net, load_scale)
|
|
72
|
+
engine = PandaPowerEngine()
|
|
73
|
+
engine.network = net
|
|
74
|
+
bus_with_flex = get_downstream_buses(net, 73)
|
|
75
|
+
loads_with_flex = net["load"].loc[net["load"]["bus"].isin(bus_with_flex)]
|
|
76
|
+
engine.flexibility_settings["load"] = {
|
|
77
|
+
name: flexibility_pct for name in loads_with_flex["name"].tolist()
|
|
78
|
+
}
|
|
79
|
+
engine.run_power_flow()
|
|
80
|
+
engine.check_violations()
|
|
81
|
+
engine.plot_network_violations(
|
|
82
|
+
show_ids=False,
|
|
83
|
+
rc_params={
|
|
84
|
+
"figure": {"size": (10, 10)},
|
|
85
|
+
"bus": {
|
|
86
|
+
"size": 100.0,
|
|
87
|
+
},
|
|
88
|
+
},
|
|
89
|
+
)
|
|
90
|
+
|
|
91
|
+
return engine
|
|
92
|
+
|
|
93
|
+
|
|
94
|
+
def create_strategy(
|
|
95
|
+
line_upgrade=True, transformer_upgrade=True, flexibility=True, tap_change=True
|
|
96
|
+
):
|
|
97
|
+
registry = EnhancementStrategyRegistry()
|
|
98
|
+
# Add line upgrade strategies
|
|
99
|
+
line_upgrade_strategy = LineUpgradeStrategy(
|
|
100
|
+
line_types=SIMBENCH.line_types,
|
|
101
|
+
max_iterations=SIMBENCH.line_upgrade_max_iterations,
|
|
102
|
+
min_voltage_sensitivity=SIMBENCH.line_upgrade_min_voltage_sensitivity,
|
|
103
|
+
)
|
|
104
|
+
|
|
105
|
+
# Add custom transformer upgrade strategy
|
|
106
|
+
transformer_upgrade_strategy = TransformerUpgradeStrategy(
|
|
107
|
+
transformer_types=SIMBENCH.trafo_types
|
|
108
|
+
)
|
|
109
|
+
if transformer_upgrade:
|
|
110
|
+
registry.register_strategy(transformer_upgrade_strategy)
|
|
111
|
+
if line_upgrade:
|
|
112
|
+
registry.register_strategy(line_upgrade_strategy)
|
|
113
|
+
if flexibility:
|
|
114
|
+
registry.register_strategy(
|
|
115
|
+
FlexibilityStrategy(n_activation=SIMBENCH.flexibility_n_activation)
|
|
116
|
+
)
|
|
117
|
+
if tap_change:
|
|
118
|
+
registry.register_strategy(TapChangeStrategy())
|
|
119
|
+
|
|
120
|
+
return registry
|
|
121
|
+
|
|
122
|
+
|
|
123
|
+
def create_cost_model():
|
|
124
|
+
return CostModel(SIMBENCH.unit_costs)
|
|
125
|
+
|
|
126
|
+
|
|
127
|
+
def run_case_study(
|
|
128
|
+
load_scale=1.7,
|
|
129
|
+
flexibility_pct=10.0,
|
|
130
|
+
line_upgrade=True,
|
|
131
|
+
transformer_upgrade=True,
|
|
132
|
+
flexibility=True,
|
|
133
|
+
tap_change=True,
|
|
134
|
+
):
|
|
135
|
+
engine = create_case_study(load_scale, flexibility_pct)
|
|
136
|
+
registry = create_strategy(
|
|
137
|
+
line_upgrade, transformer_upgrade, flexibility, tap_change
|
|
138
|
+
)
|
|
139
|
+
cost_model = create_cost_model()
|
|
140
|
+
ge = GridEnhancementAlgorithm(
|
|
141
|
+
power_flow_engine=engine,
|
|
142
|
+
cost_model=cost_model,
|
|
143
|
+
max_iterations=SIMBENCH.algorithm_max_iterations,
|
|
144
|
+
strategy_registry=registry,
|
|
145
|
+
)
|
|
146
|
+
success, results = ge.run()
|
|
147
|
+
engine.plot_network_violations(
|
|
148
|
+
show_ids=False,
|
|
149
|
+
enhancement_results=results,
|
|
150
|
+
rc_params={
|
|
151
|
+
"figure": {"size": (10, 10)},
|
|
152
|
+
"bus": {
|
|
153
|
+
"size": 100.0,
|
|
154
|
+
},
|
|
155
|
+
},
|
|
156
|
+
)
|
|
157
|
+
return results["summary"]
|
|
158
|
+
|
|
159
|
+
|
|
160
|
+
if __name__ == "__main__":
|
|
161
|
+
res_list = []
|
|
162
|
+
for flex in [0.0, 25.0]:
|
|
163
|
+
res = run_case_study(flexibility_pct=flex, load_scale=1.5)
|
|
164
|
+
res["flexibility_pct"] = flex
|
|
165
|
+
res_list.append(res)
|
|
166
|
+
|
|
167
|
+
res_total = pd.DataFrame.from_records(res_list)
|
|
168
|
+
res_total.to_csv("test_case_results.csv")
|
|
File without changes
|