distgridforge 0.3.0__py3-none-any.whl
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- distgridforge-0.3.0.dist-info/METADATA +266 -0
- distgridforge-0.3.0.dist-info/RECORD +38 -0
- distgridforge-0.3.0.dist-info/WHEEL +5 -0
- distgridforge-0.3.0.dist-info/licenses/LICENCE.txt +21 -0
- distgridforge-0.3.0.dist-info/top_level.txt +1 -0
- gridforge/__init__.py +32 -0
- gridforge/case_study/config.py +158 -0
- gridforge/case_study/dickert_lv_network_script.py +109 -0
- gridforge/case_study/mv_lv_feeder.py +314 -0
- gridforge/case_study/simbench_network_test_case.py +168 -0
- gridforge/core/__init__.py +0 -0
- gridforge/core/constraints.py +421 -0
- gridforge/core/cost_model.py +363 -0
- gridforge/core/grid_enhancement.py +1932 -0
- gridforge/core/power_flow.py +1146 -0
- gridforge/core/strategy.py +297 -0
- gridforge/engines/__init__.py +0 -0
- gridforge/engines/gridlabd_engine.py +527 -0
- gridforge/engines/opendss_engine.py +885 -0
- gridforge/engines/pandapower_engine.py +3766 -0
- gridforge/engines/roseau_engine.py +1234 -0
- gridforge/examples/__init__.py +0 -0
- gridforge/examples/quick_start.py +85 -0
- gridforge/main.py +0 -0
- gridforge/strategies/__init__.py +0 -0
- gridforge/strategies/flexibility.py +1476 -0
- gridforge/strategies/line_upgrade.py +1846 -0
- gridforge/strategies/path_to_source.py +596 -0
- gridforge/strategies/sizing.py +210 -0
- gridforge/strategies/step_check.py +183 -0
- gridforge/strategies/tap_change.py +267 -0
- gridforge/strategies/transformer_upgrade.py +622 -0
- gridforge/utils/__init__.py +0 -0
- gridforge/utils/config.py +55 -0
- gridforge/utils/interactive_plot.py +700 -0
- gridforge/utils/logging.py +86 -0
- gridforge/utils/plot.py +1078 -0
- gridforge/utils/reporting.py +0 -0
|
@@ -0,0 +1,3766 @@
|
|
|
1
|
+
"""
|
|
2
|
+
PandaPower engine implementation for power flow analysis in GridForge.
|
|
3
|
+
"""
|
|
4
|
+
|
|
5
|
+
import copy
|
|
6
|
+
import numbers
|
|
7
|
+
from typing import Any
|
|
8
|
+
|
|
9
|
+
import numpy as np
|
|
10
|
+
import pandapower as pp
|
|
11
|
+
import pandas as pd
|
|
12
|
+
from pandas.api.types import infer_dtype
|
|
13
|
+
from scipy import sparse
|
|
14
|
+
from scipy.sparse.linalg import splu
|
|
15
|
+
|
|
16
|
+
from gridforge.core.power_flow import PowerFlowEngine, PowerFlowNotConverged
|
|
17
|
+
|
|
18
|
+
# Error of the sensitivities without a converged run of the engine for the network
|
|
19
|
+
_NO_CONVERGED_RUN = (
|
|
20
|
+
"No converged power flow of the engine for this network: call run_power_flow "
|
|
21
|
+
"before calculating sensitivities. They answer only from the engine's own run, whose "
|
|
22
|
+
"controllers converged and whose network passed check_names, not from the results "
|
|
23
|
+
"of a power flow run on the network outside the engine (pp.runpp)."
|
|
24
|
+
)
|
|
25
|
+
|
|
26
|
+
# Error of the sensitivities of a network that has changed since the last run
|
|
27
|
+
_STALE_TABLES = (
|
|
28
|
+
"The buses, lines or transformers of the network are not those of the last power "
|
|
29
|
+
"flow: run a power flow before calculating sensitivities."
|
|
30
|
+
)
|
|
31
|
+
|
|
32
|
+
# The tables and columns from which pandapower's topology graph (`create_nxgraph`, as
|
|
33
|
+
# `unsupplied_buses` calls it in pandapower 3.2) tells which buses no source supplies:
|
|
34
|
+
# its nodes, its edges, the switches it respects and the sources. The dead buses of the
|
|
35
|
+
# engine are recomputed whenever one of them changes, and only then.
|
|
36
|
+
_TOPOLOGY_TABLES = (
|
|
37
|
+
"bus",
|
|
38
|
+
"line",
|
|
39
|
+
"trafo",
|
|
40
|
+
"trafo3w",
|
|
41
|
+
"impedance",
|
|
42
|
+
"dcline",
|
|
43
|
+
"tcsc",
|
|
44
|
+
"vsc",
|
|
45
|
+
"line_dc",
|
|
46
|
+
"bus_dc",
|
|
47
|
+
"switch",
|
|
48
|
+
"ext_grid",
|
|
49
|
+
"gen",
|
|
50
|
+
)
|
|
51
|
+
_TOPOLOGY_COLUMNS = (
|
|
52
|
+
"in_service",
|
|
53
|
+
"bus",
|
|
54
|
+
"from_bus",
|
|
55
|
+
"to_bus",
|
|
56
|
+
"hv_bus",
|
|
57
|
+
"mv_bus",
|
|
58
|
+
"lv_bus",
|
|
59
|
+
"bus_dc",
|
|
60
|
+
"from_bus_dc",
|
|
61
|
+
"to_bus_dc",
|
|
62
|
+
"element",
|
|
63
|
+
"et",
|
|
64
|
+
"closed",
|
|
65
|
+
"slack",
|
|
66
|
+
"control_mode_ac",
|
|
67
|
+
)
|
|
68
|
+
|
|
69
|
+
|
|
70
|
+
class PandaPowerNotConverged(PowerFlowNotConverged, pp.LoadflowNotConverged):
|
|
71
|
+
"""
|
|
72
|
+
Raised by `PandaPowerEngine.run_power_flow` when the power flow does not converge.
|
|
73
|
+
|
|
74
|
+
It is both the engine-independent `PowerFlowNotConverged` and pandapower's
|
|
75
|
+
`LoadflowNotConverged`, so that code written against pandapower, which catches the
|
|
76
|
+
latter around a power flow, still sees a divergence.
|
|
77
|
+
"""
|
|
78
|
+
|
|
79
|
+
|
|
80
|
+
class PandaPowerControllerNotConverged(
|
|
81
|
+
PandaPowerNotConverged, pp.ControllerNotConverged
|
|
82
|
+
):
|
|
83
|
+
"""
|
|
84
|
+
Raised by `PandaPowerEngine.run_power_flow` when the controllers do not converge.
|
|
85
|
+
|
|
86
|
+
As `PandaPowerNotConverged`, and pandapower's `ControllerNotConverged` as well.
|
|
87
|
+
"""
|
|
88
|
+
|
|
89
|
+
|
|
90
|
+
class PandaPowerEngine(PowerFlowEngine):
|
|
91
|
+
"""
|
|
92
|
+
Interface to PandaPower for power flow calculations and network analysis.
|
|
93
|
+
|
|
94
|
+
This engine provides methods to:
|
|
95
|
+
|
|
96
|
+
1. Load network models
|
|
97
|
+
2. Run power flow calculations
|
|
98
|
+
3. Apply network modifications
|
|
99
|
+
4. Check constraint violations
|
|
100
|
+
5. Extract results and metrics
|
|
101
|
+
|
|
102
|
+
Buses, lines and transformers are identified by their name: in the violations, the
|
|
103
|
+
sensitivities, the actions of the strategies and the paths they search. Loads and
|
|
104
|
+
static generators are identified by their index (`get_flexibility_data`,
|
|
105
|
+
`apply_flexibility_action`, the flexibility actions), but `flexibility_settings` is
|
|
106
|
+
keyed by their name. Each of these elements must therefore have a name (not None,
|
|
107
|
+
NaN or ""), and two buses, two lines, two transformers, two loads or two static
|
|
108
|
+
generators must not have the same, which `check_names` checks, and `run_power_flow`
|
|
109
|
+
before each run; elements of different tables may share one (a bus and a line, a
|
|
110
|
+
load and a static generator). `fill_missing_names` names the elements that have no
|
|
111
|
+
name.
|
|
112
|
+
"""
|
|
113
|
+
|
|
114
|
+
def __init__(self, config: dict[str, Any] | None = None):
|
|
115
|
+
"""
|
|
116
|
+
Initialize PandaPower engine.
|
|
117
|
+
|
|
118
|
+
Args:
|
|
119
|
+
config (Optional[Dict[str, Any]], optional): Configuration dictionary with PandaPower specific settings. Defaults to None.
|
|
120
|
+
"""
|
|
121
|
+
# Jacobian at the solution of the last run, with the voltages it was built at
|
|
122
|
+
self._jacobian_cache: tuple[np.ndarray, sparse.csr_matrix] | None = None
|
|
123
|
+
# LU factors of that Jacobian, with the Jacobian they factorise
|
|
124
|
+
self._jacobian_lu_cache: tuple[sparse.csr_matrix, Any] | None = None
|
|
125
|
+
# Dead buses (see `_dead_buses`), with the topology they were found in
|
|
126
|
+
self._dead_buses_cache: tuple[tuple, frozenset[int]] | None = None
|
|
127
|
+
super().__init__(config)
|
|
128
|
+
|
|
129
|
+
@property
|
|
130
|
+
def network(self) -> Any:
|
|
131
|
+
"""The pandapower network of the engine."""
|
|
132
|
+
return self._network
|
|
133
|
+
|
|
134
|
+
@network.setter
|
|
135
|
+
def network(self, network: Any) -> None:
|
|
136
|
+
# What the engine remembers of the last run describes the former network: with
|
|
137
|
+
# the same buses, its results would otherwise pass for those of the new one, in
|
|
138
|
+
# `check_violations` and as the starting point of a warm start. To put back a
|
|
139
|
+
# network together with its results, assign `latest_results` after it.
|
|
140
|
+
self._network = network
|
|
141
|
+
self.latest_results = None
|
|
142
|
+
self.network_partition = None
|
|
143
|
+
self._jacobian_cache = None
|
|
144
|
+
self._jacobian_lu_cache = None
|
|
145
|
+
self._dead_buses_cache = None
|
|
146
|
+
|
|
147
|
+
def __getstate__(self) -> dict[str, Any]:
|
|
148
|
+
"""
|
|
149
|
+
State of the engine for `pickle` and `copy`, without the caches.
|
|
150
|
+
|
|
151
|
+
The LU factors of the Jacobian cannot be pickled, and the caches are rebuilt on
|
|
152
|
+
demand from the solution and the topology, which the network carries.
|
|
153
|
+
"""
|
|
154
|
+
state = self.__dict__.copy()
|
|
155
|
+
state["_jacobian_cache"] = None
|
|
156
|
+
state["_jacobian_lu_cache"] = None
|
|
157
|
+
state["_dead_buses_cache"] = None
|
|
158
|
+
return state
|
|
159
|
+
|
|
160
|
+
def __setstate__(self, state: dict[str, Any]) -> None:
|
|
161
|
+
"""
|
|
162
|
+
Restore an engine, including one pickled by a gridforge that had fewer caches.
|
|
163
|
+
|
|
164
|
+
A cache the state lacks starts empty, as `__getstate__` leaves the others.
|
|
165
|
+
"""
|
|
166
|
+
self.__dict__.update(state)
|
|
167
|
+
for cache in ("_jacobian_cache", "_jacobian_lu_cache", "_dead_buses_cache"):
|
|
168
|
+
self.__dict__.setdefault(cache, None)
|
|
169
|
+
|
|
170
|
+
def fill_missing_names(self):
|
|
171
|
+
"""
|
|
172
|
+
Name the buses, lines, transformers, loads and static generators that have no
|
|
173
|
+
name (None, NaN or "").
|
|
174
|
+
|
|
175
|
+
The names are ``bus_<index>``, ``line_<index>_<from bus>_to_<to bus>``,
|
|
176
|
+
``trafo_<index>_<hv bus>_to_<lv bus>``, ``load_<index>_<bus>`` and
|
|
177
|
+
``sgen_<index>_<bus>``, after the buses are named. A name that another element
|
|
178
|
+
of the same table already has is followed by ``_2`` (or ``_3``, and so on,
|
|
179
|
+
until it is free), so that the names given are never shared: a bus without a
|
|
180
|
+
name at index 3 next to a bus called ``bus_3`` is called ``bus_3_2``. Names
|
|
181
|
+
already there, shared or not, are left as they are: `check_names` reports the
|
|
182
|
+
shared ones, which are for the caller to change. Call it before the first power
|
|
183
|
+
flow: `check_names` refuses unnamed elements.
|
|
184
|
+
|
|
185
|
+
A load or a static generator named here has no entry in `flexibility_settings`,
|
|
186
|
+
and so no flexibility, until one is given under its new name.
|
|
187
|
+
"""
|
|
188
|
+
net = self.network
|
|
189
|
+
|
|
190
|
+
def fill(table: pd.DataFrame, names_of) -> None:
|
|
191
|
+
column = table.get("name")
|
|
192
|
+
if column is None:
|
|
193
|
+
column = pd.Series(None, index=table.index, dtype=object)
|
|
194
|
+
missing = column.isna() | (column == "")
|
|
195
|
+
if not missing.any():
|
|
196
|
+
return
|
|
197
|
+
# A missing column, or one that cannot take a new string (categorical, all
|
|
198
|
+
# NaN as a float), becomes a column of objects
|
|
199
|
+
if column.dtype != object:
|
|
200
|
+
column = column.astype(object)
|
|
201
|
+
table["name"] = column
|
|
202
|
+
taken = set(column[~missing])
|
|
203
|
+
given = []
|
|
204
|
+
for name in names_of(table.loc[missing]):
|
|
205
|
+
free, k = name, 1
|
|
206
|
+
while free in taken:
|
|
207
|
+
k += 1
|
|
208
|
+
free = f"{name}_{k}"
|
|
209
|
+
taken.add(free)
|
|
210
|
+
given.append(free)
|
|
211
|
+
table.loc[missing, "name"] = given
|
|
212
|
+
|
|
213
|
+
def bus_names(buses: pd.Series) -> list[str]:
|
|
214
|
+
return net.bus.loc[buses, "name"].astype(str).tolist()
|
|
215
|
+
|
|
216
|
+
fill(net.bus, lambda rows: [f"bus_{i}" for i in rows.index])
|
|
217
|
+
# After the buses, whose names are in those of the branches
|
|
218
|
+
fill(
|
|
219
|
+
net.line,
|
|
220
|
+
lambda rows: [
|
|
221
|
+
f"line_{i}_{f}_to_{t}"
|
|
222
|
+
for i, f, t in zip(
|
|
223
|
+
rows.index,
|
|
224
|
+
bus_names(rows["from_bus"]),
|
|
225
|
+
bus_names(rows["to_bus"]),
|
|
226
|
+
strict=True,
|
|
227
|
+
)
|
|
228
|
+
],
|
|
229
|
+
)
|
|
230
|
+
fill(
|
|
231
|
+
net.trafo,
|
|
232
|
+
lambda rows: [
|
|
233
|
+
f"trafo_{i}_{hv}_to_{lv}"
|
|
234
|
+
for i, hv, lv in zip(
|
|
235
|
+
rows.index,
|
|
236
|
+
bus_names(rows["hv_bus"]),
|
|
237
|
+
bus_names(rows["lv_bus"]),
|
|
238
|
+
strict=True,
|
|
239
|
+
)
|
|
240
|
+
],
|
|
241
|
+
)
|
|
242
|
+
for element in ("load", "sgen"):
|
|
243
|
+
table = getattr(net, element, None)
|
|
244
|
+
if table is None or table.empty:
|
|
245
|
+
continue
|
|
246
|
+
fill(
|
|
247
|
+
table,
|
|
248
|
+
lambda rows, element=element: [
|
|
249
|
+
f"{element}_{i}_{bus}"
|
|
250
|
+
for i, bus in zip(rows.index, bus_names(rows["bus"]), strict=True)
|
|
251
|
+
],
|
|
252
|
+
)
|
|
253
|
+
|
|
254
|
+
def create_empty_network(
|
|
255
|
+
self, name: str = "grid-forge-network", f_hz: float = 50.0
|
|
256
|
+
) -> None:
|
|
257
|
+
"""
|
|
258
|
+
Create an empty pandapower network.
|
|
259
|
+
|
|
260
|
+
Args:
|
|
261
|
+
name (str, optional): Name of the network. Defaults to "grid-forge-network".
|
|
262
|
+
f_hz (float, optional): System frequency in Hz. Defaults to 50.0.
|
|
263
|
+
"""
|
|
264
|
+
self.network = pp.create_empty_network(name=name, f_hz=f_hz)
|
|
265
|
+
self.logger.info(f"Created empty network: {name}")
|
|
266
|
+
|
|
267
|
+
def create_bus(self, name: str, nominal_voltage_v: float, **kwargs: Any):
|
|
268
|
+
"""
|
|
269
|
+
Create a new bus in the PandaPower network.
|
|
270
|
+
|
|
271
|
+
Args:
|
|
272
|
+
name (str): Name of the bus.
|
|
273
|
+
nominal_voltage_v (float): Nominal voltage of the bus in kV.
|
|
274
|
+
**kwargs: Additional parameters for the bus.
|
|
275
|
+
|
|
276
|
+
Returns:
|
|
277
|
+
int: Index of the created bus.
|
|
278
|
+
"""
|
|
279
|
+
if self.network is None:
|
|
280
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
281
|
+
|
|
282
|
+
# Convert generic parameters to pandapower-specific parameters
|
|
283
|
+
pp_params = {"name": name, "vn_kv": nominal_voltage_v * 1.0e-3}
|
|
284
|
+
|
|
285
|
+
# Add any additional parameters
|
|
286
|
+
pp_params.update(kwargs)
|
|
287
|
+
|
|
288
|
+
# Create the bus in the pandapower network
|
|
289
|
+
return pp.create_bus(self.network, **pp_params)
|
|
290
|
+
|
|
291
|
+
def create_load(
|
|
292
|
+
self,
|
|
293
|
+
bus_name: str,
|
|
294
|
+
name: str,
|
|
295
|
+
active_power_w: float,
|
|
296
|
+
reactive_power_var: float,
|
|
297
|
+
**kwargs: Any,
|
|
298
|
+
):
|
|
299
|
+
"""
|
|
300
|
+
Create a new load in the PandaPower network.
|
|
301
|
+
|
|
302
|
+
Args:
|
|
303
|
+
bus_name (str): Name of the bus where the load is connected.
|
|
304
|
+
name (str): Name of the load.
|
|
305
|
+
active_power_w (float): Active power of the load in W.
|
|
306
|
+
reactive_power_var (float): Reactive power of the load in VAr.
|
|
307
|
+
**kwargs: Additional parameters for the load. `max_flex_pct` is the
|
|
308
|
+
share of its active power, in percent, that `FlexibilityStrategy` can
|
|
309
|
+
take off, counted from its power as each run starts, or at each call
|
|
310
|
+
of a strategy used on its own (see `FlexibilityStrategy.initial_power`
|
|
311
|
+
for a strategy called several times).
|
|
312
|
+
|
|
313
|
+
Returns:
|
|
314
|
+
int: Index of the created load.
|
|
315
|
+
|
|
316
|
+
Raises:
|
|
317
|
+
ValueError: If `name` is None, NaN or "", or the name of a load already in
|
|
318
|
+
the network, before anything is created: its `max_flex_pct` would be
|
|
319
|
+
stored under the name of the other load, whose flexibility it would
|
|
320
|
+
change, and `check_names` refuses such a network anyway.
|
|
321
|
+
"""
|
|
322
|
+
if self.network is None:
|
|
323
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
324
|
+
self._refuse_name_of_a_new_element("load", "load", name)
|
|
325
|
+
|
|
326
|
+
buses = self.network.bus
|
|
327
|
+
bus_id = buses.loc[buses["name"] == bus_name].index[0]
|
|
328
|
+
# Convert generic parameters to pandapower-specific parameters
|
|
329
|
+
pp_params = {
|
|
330
|
+
"bus": bus_id,
|
|
331
|
+
"name": name,
|
|
332
|
+
"p_mw": round(active_power_w * 1.0e-6, 6),
|
|
333
|
+
"q_mvar": round(reactive_power_var * 1.0e-6, 6),
|
|
334
|
+
}
|
|
335
|
+
|
|
336
|
+
# Store flexibility setting if provided
|
|
337
|
+
if "max_flex_pct" in kwargs:
|
|
338
|
+
self.flexibility_settings["load"][name] = kwargs.pop("max_flex_pct")
|
|
339
|
+
|
|
340
|
+
# Add any additional parameters
|
|
341
|
+
pp_params.update(kwargs)
|
|
342
|
+
|
|
343
|
+
# Create the load in the pandapower network
|
|
344
|
+
return pp.create_load(self.network, **pp_params)
|
|
345
|
+
|
|
346
|
+
def create_generator(
|
|
347
|
+
self,
|
|
348
|
+
bus_name: str,
|
|
349
|
+
name: str,
|
|
350
|
+
active_power_w: float,
|
|
351
|
+
reactive_power_var: float,
|
|
352
|
+
**kwargs: Any,
|
|
353
|
+
):
|
|
354
|
+
"""
|
|
355
|
+
Create a new static generator in the PandaPower network.
|
|
356
|
+
|
|
357
|
+
Args:
|
|
358
|
+
bus_name (str): Name of the bus where the generator is connected.
|
|
359
|
+
name (str): Name of the generator.
|
|
360
|
+
active_power_w (float): Active power of the generator in W.
|
|
361
|
+
reactive_power_var (float): Reactive power of the generator in VAr.
|
|
362
|
+
**kwargs: Additional parameters for the generator. `max_flex_pct` is the
|
|
363
|
+
share of its active power, in percent, that `FlexibilityStrategy` can
|
|
364
|
+
take off, counted from its power as each run starts, or at each call
|
|
365
|
+
of a strategy used on its own (see `FlexibilityStrategy.initial_power`
|
|
366
|
+
for a strategy called several times).
|
|
367
|
+
|
|
368
|
+
Returns:
|
|
369
|
+
int: Index of the created generator.
|
|
370
|
+
|
|
371
|
+
Raises:
|
|
372
|
+
ValueError: If `name` is None, NaN or "", or the name of a static generator
|
|
373
|
+
already in the network, before anything is created: its `max_flex_pct`
|
|
374
|
+
would be stored under the name of the other generator, whose flexibility
|
|
375
|
+
it would change, and `check_names` refuses such a network anyway.
|
|
376
|
+
"""
|
|
377
|
+
if self.network is None:
|
|
378
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
379
|
+
self._refuse_name_of_a_new_element("sgen", "static generator", name)
|
|
380
|
+
|
|
381
|
+
buses = self.network.bus
|
|
382
|
+
bus_id = buses.loc[buses["name"] == bus_name].index[0]
|
|
383
|
+
|
|
384
|
+
# Convert generic parameters to pandapower-specific parameters
|
|
385
|
+
pp_params = {
|
|
386
|
+
"bus": bus_id,
|
|
387
|
+
"name": name,
|
|
388
|
+
"p_mw": round(active_power_w * 1.0e-6, 6),
|
|
389
|
+
"q_mvar": round(reactive_power_var * 1.0e-6, 6),
|
|
390
|
+
}
|
|
391
|
+
|
|
392
|
+
# Store flexibility setting if provided
|
|
393
|
+
if "max_flex_pct" in kwargs:
|
|
394
|
+
self.flexibility_settings["sgen"][name] = kwargs.pop("max_flex_pct")
|
|
395
|
+
|
|
396
|
+
# Add any additional parameters
|
|
397
|
+
pp_params.update(kwargs)
|
|
398
|
+
|
|
399
|
+
# Create the static generator in the pandapower network
|
|
400
|
+
return pp.create_sgen(self.network, **pp_params)
|
|
401
|
+
|
|
402
|
+
def _refuse_name_of_a_new_element(
|
|
403
|
+
self, element: str, label: str, name: Any
|
|
404
|
+
) -> None:
|
|
405
|
+
"""
|
|
406
|
+
Raise a ValueError if an element of the table `element` cannot be created with
|
|
407
|
+
`name`: it is None, NaN or "", or another element of the table has it.
|
|
408
|
+
"""
|
|
409
|
+
# pd.isna first: NA (pd.NA) cannot be compared with ""
|
|
410
|
+
if (
|
|
411
|
+
name is None
|
|
412
|
+
or (pd.api.types.is_scalar(name) and pd.isna(name))
|
|
413
|
+
or name == ""
|
|
414
|
+
):
|
|
415
|
+
raise ValueError(
|
|
416
|
+
f"A {label} must have a name (not None, NaN or ''), by which its "
|
|
417
|
+
"flexibility settings are kept and `check_names` tells it apart."
|
|
418
|
+
)
|
|
419
|
+
table = getattr(self.network, element, None)
|
|
420
|
+
if table is None or "name" not in table.columns:
|
|
421
|
+
return
|
|
422
|
+
taken = table.index[table["name"] == name]
|
|
423
|
+
if len(taken):
|
|
424
|
+
raise ValueError(
|
|
425
|
+
f"A {label} named {name!r} is already in the network (index "
|
|
426
|
+
f"{', '.join(str(i) for i in taken)}): two {label}s must not share a name, "
|
|
427
|
+
"by which their flexibility settings are kept."
|
|
428
|
+
)
|
|
429
|
+
|
|
430
|
+
def create_line(
|
|
431
|
+
self,
|
|
432
|
+
name: str,
|
|
433
|
+
from_bus: str,
|
|
434
|
+
to_bus: str,
|
|
435
|
+
length_km: float,
|
|
436
|
+
line_type: str,
|
|
437
|
+
**kwargs: Any,
|
|
438
|
+
):
|
|
439
|
+
"""
|
|
440
|
+
Create a new line in the PandaPower network.
|
|
441
|
+
|
|
442
|
+
Args:
|
|
443
|
+
name (str): Name of the line.
|
|
444
|
+
from_bus (int): ID of the starting bus.
|
|
445
|
+
to_bus (int): ID of the ending bus.
|
|
446
|
+
length_km (float): Length of the line in kilometers.
|
|
447
|
+
line_type (str): Type of the line (refers to standard types in pandapower).
|
|
448
|
+
**kwargs: Additional parameters for the line.
|
|
449
|
+
|
|
450
|
+
Returns:
|
|
451
|
+
int: Index of the created line.
|
|
452
|
+
"""
|
|
453
|
+
if self.network is None:
|
|
454
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
455
|
+
|
|
456
|
+
buses = self.network.bus
|
|
457
|
+
from_bus_id = buses.loc[buses["name"] == from_bus].index[0]
|
|
458
|
+
to_bus_id = buses.loc[buses["name"] == to_bus].index[0]
|
|
459
|
+
# Convert generic parameters to pandapower-specific parameters
|
|
460
|
+
pp_params = {
|
|
461
|
+
"name": name,
|
|
462
|
+
"from_bus": from_bus_id,
|
|
463
|
+
"to_bus": to_bus_id,
|
|
464
|
+
"length_km": length_km,
|
|
465
|
+
"std_type": line_type,
|
|
466
|
+
}
|
|
467
|
+
|
|
468
|
+
# Add any additional parameters
|
|
469
|
+
pp_params.update(kwargs)
|
|
470
|
+
|
|
471
|
+
# Create the line in the pandapower network
|
|
472
|
+
return pp.create_line(self.network, **pp_params)
|
|
473
|
+
|
|
474
|
+
def create_ext_grid(
|
|
475
|
+
self,
|
|
476
|
+
bus_name: str,
|
|
477
|
+
name: str,
|
|
478
|
+
voltage_reference_pu: float,
|
|
479
|
+
angle_reference_degree: float = 0,
|
|
480
|
+
**kwargs: Any,
|
|
481
|
+
):
|
|
482
|
+
"""
|
|
483
|
+
Create a new external grid connection in the PandaPower network.
|
|
484
|
+
|
|
485
|
+
Args:
|
|
486
|
+
bus_name (str): Name of the bus where the external grid is connected.
|
|
487
|
+
name (str): Name of the external grid.
|
|
488
|
+
voltage_reference_pu (float): Voltage magnitude in per unit.
|
|
489
|
+
angle_reference_degree (float, optional): Voltage angle in degrees. Defaults to 0.
|
|
490
|
+
**kwargs: Additional parameters for the external grid.
|
|
491
|
+
|
|
492
|
+
Returns:
|
|
493
|
+
int: Index of the created external grid.
|
|
494
|
+
"""
|
|
495
|
+
if self.network is None:
|
|
496
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
497
|
+
|
|
498
|
+
buses = self.network.bus
|
|
499
|
+
bus_id = buses.loc[buses["name"] == bus_name].index[0]
|
|
500
|
+
|
|
501
|
+
# Convert generic parameters to pandapower-specific parameters
|
|
502
|
+
pp_params = {
|
|
503
|
+
"bus": bus_id,
|
|
504
|
+
"name": name,
|
|
505
|
+
"vm_pu": voltage_reference_pu,
|
|
506
|
+
"va_degree": angle_reference_degree,
|
|
507
|
+
}
|
|
508
|
+
|
|
509
|
+
# Add any additional parameters
|
|
510
|
+
pp_params.update(kwargs)
|
|
511
|
+
|
|
512
|
+
# Create the external grid in the pandapower network
|
|
513
|
+
return pp.create_ext_grid(self.network, **pp_params)
|
|
514
|
+
|
|
515
|
+
def create_transformer(
|
|
516
|
+
self, name: str, hv_bus: str, lv_bus: str, transformer_type: str, **kwargs: Any
|
|
517
|
+
):
|
|
518
|
+
"""
|
|
519
|
+
Create a new transformer in the PandaPower network.
|
|
520
|
+
|
|
521
|
+
Args:
|
|
522
|
+
name (str): Name of the transformer.
|
|
523
|
+
hv_bus (str): Name of the high voltage bus.
|
|
524
|
+
lv_bus (str): Name of the low voltage bus.
|
|
525
|
+
transformer_type (str): Type of the transformer (refers to standard types in pandapower).
|
|
526
|
+
**kwargs: Additional parameters for the transformer.
|
|
527
|
+
|
|
528
|
+
Returns:
|
|
529
|
+
int: Index of the created transformer.
|
|
530
|
+
"""
|
|
531
|
+
if self.network is None:
|
|
532
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
533
|
+
|
|
534
|
+
buses = self.network.bus
|
|
535
|
+
hv_bus_id = buses.loc[buses["name"] == hv_bus].index[0]
|
|
536
|
+
lv_bus_id = buses.loc[buses["name"] == lv_bus].index[0]
|
|
537
|
+
|
|
538
|
+
# Convert generic parameters to pandapower-specific parameters
|
|
539
|
+
pp_params = {
|
|
540
|
+
"name": name,
|
|
541
|
+
"hv_bus": hv_bus_id,
|
|
542
|
+
"lv_bus": lv_bus_id,
|
|
543
|
+
"std_type": transformer_type,
|
|
544
|
+
}
|
|
545
|
+
|
|
546
|
+
# Add any additional parameters
|
|
547
|
+
pp_params.update(kwargs)
|
|
548
|
+
|
|
549
|
+
# Create the transformer in the pandapower network
|
|
550
|
+
return pp.create_transformer(self.network, **pp_params)
|
|
551
|
+
|
|
552
|
+
def load_network(self, source: str | dict) -> None:
|
|
553
|
+
"""
|
|
554
|
+
Load a network from file or dictionary.
|
|
555
|
+
|
|
556
|
+
The results of the last run and the caches of the engine are forgotten, as
|
|
557
|
+
whenever a network is assigned to `network`: a power flow must be run again.
|
|
558
|
+
|
|
559
|
+
Args:
|
|
560
|
+
source (Union[str, Dict]): Path to network file (.json, .p) or network dictionary.
|
|
561
|
+
"""
|
|
562
|
+
self.logger.info("Loading network")
|
|
563
|
+
|
|
564
|
+
if isinstance(source, str):
|
|
565
|
+
if source.endswith(".json"):
|
|
566
|
+
self.network = pp.from_json(source)
|
|
567
|
+
elif source.endswith(".p"):
|
|
568
|
+
self.network = pp.from_pickle(source)
|
|
569
|
+
elif source.endswith(".xlsx"):
|
|
570
|
+
self.network = pp.from_excel(source)
|
|
571
|
+
else:
|
|
572
|
+
raise ValueError(f"Unsupported file format: {source}")
|
|
573
|
+
|
|
574
|
+
elif isinstance(source, dict):
|
|
575
|
+
self.network = pp.from_json_dict(source)
|
|
576
|
+
|
|
577
|
+
else:
|
|
578
|
+
raise TypeError("Source must be a file path or network dictionary")
|
|
579
|
+
|
|
580
|
+
self.logger.info(
|
|
581
|
+
f"Loaded network with {len(self.network.bus)} buses, "
|
|
582
|
+
f"{len(self.network.line)} lines, and {len(self.network.trafo)} transformers"
|
|
583
|
+
)
|
|
584
|
+
|
|
585
|
+
def save_network(self, target: str) -> None:
|
|
586
|
+
"""
|
|
587
|
+
Save the current network to a file.
|
|
588
|
+
|
|
589
|
+
Args:
|
|
590
|
+
target (str): Path where to save the network (.json, .p).
|
|
591
|
+
"""
|
|
592
|
+
if not self.network:
|
|
593
|
+
raise ValueError("No network loaded to save")
|
|
594
|
+
|
|
595
|
+
if target.endswith(".json"):
|
|
596
|
+
pp.to_json(self.network, target)
|
|
597
|
+
elif target.endswith(".p"):
|
|
598
|
+
pp.to_pickle(self.network, target)
|
|
599
|
+
elif target.endswith(".xlsx"):
|
|
600
|
+
pp.to_excel(self.network, target)
|
|
601
|
+
else:
|
|
602
|
+
raise ValueError(f"Unsupported file format: {target}")
|
|
603
|
+
|
|
604
|
+
self.logger.info(f"Network saved to {target}")
|
|
605
|
+
|
|
606
|
+
def run_power_flow(self, warm_start=False) -> dict[str, Any]:
|
|
607
|
+
"""
|
|
608
|
+
Run power flow calculation on the current network.
|
|
609
|
+
|
|
610
|
+
Args:
|
|
611
|
+
warm_start (bool, optional): If True, start from the previous solution, which
|
|
612
|
+
saves iterations after a small change. The run starts from scratch
|
|
613
|
+
instead if there is no previous solution, if an angle that a
|
|
614
|
+
transformer or an external grid applies has changed since it (see
|
|
615
|
+
`_phase_shifts`), or if the warm start fails before any
|
|
616
|
+
controller has acted. Warm and cold runs stop at the same
|
|
617
|
+
tolerance, at different points within it, and end at the same
|
|
618
|
+
solution after the Newton step below. Defaults to False.
|
|
619
|
+
|
|
620
|
+
Every run that converges ends with one more Newton step, from the power
|
|
621
|
+
mismatch the solver left and the Jacobian at its solution (see
|
|
622
|
+
`_take_one_more_newton_step`): the voltages, currents and loadings of the result
|
|
623
|
+
tables, and the internal voltages from which the sensitivities are computed,
|
|
624
|
+
are those of the solution after it.
|
|
625
|
+
|
|
626
|
+
Returns:
|
|
627
|
+
Dict[str, Any]: Dictionary with power flow results and statistics.
|
|
628
|
+
|
|
629
|
+
Raises:
|
|
630
|
+
PowerFlowNotConverged: If the power flow, or a controller run with it, does not
|
|
631
|
+
converge. Whatever the way a run fails, the result tables of the network
|
|
632
|
+
are then unusable and `latest_results["converged"]` is False. The
|
|
633
|
+
exception is a `PandaPowerNotConverged`, which is also pandapower's
|
|
634
|
+
`LoadflowNotConverged` (and its `ControllerNotConverged` when the
|
|
635
|
+
controllers are what failed), so either can be caught.
|
|
636
|
+
ValueError: If a bus, a line, a transformer, a load or a static generator
|
|
637
|
+
has no name, or the same name as another of its table (see
|
|
638
|
+
`check_names`), before any power flow;
|
|
639
|
+
`latest_results["converged"]` is then False.
|
|
640
|
+
"""
|
|
641
|
+
if not self.network:
|
|
642
|
+
raise ValueError("No network loaded for power flow calculation")
|
|
643
|
+
|
|
644
|
+
self.logger.info("Running power flow calculation")
|
|
645
|
+
|
|
646
|
+
# Until this run succeeds, the results of the previous one must not pass for the
|
|
647
|
+
# current ones: a run that fails, in whatever way, leaves unusable (NaN) result
|
|
648
|
+
# tables, and `check_violations` would otherwise still read them as converged.
|
|
649
|
+
# Nothing that can fail runs before: what the warm start needs of them is kept
|
|
650
|
+
# here.
|
|
651
|
+
previous = self.latest_results
|
|
652
|
+
self.latest_results = {"converged": False, "iterations": None, "time": None}
|
|
653
|
+
# The Jacobian of the previous solution will not be needed again
|
|
654
|
+
self._jacobian_cache = None
|
|
655
|
+
self._jacobian_lu_cache = None
|
|
656
|
+
# Start from the previous solution only if there is one for this network: a failed
|
|
657
|
+
# run leaves NaN result tables, which are no starting point, and a solution with
|
|
658
|
+
# other applied angles is the new one rotated (see `_phase_shifts`).
|
|
659
|
+
shifts = self._phase_shifts()
|
|
660
|
+
warm_start = (
|
|
661
|
+
warm_start
|
|
662
|
+
and self._has_solution(previous)
|
|
663
|
+
and self._same_phase_shifts(previous.get("_phase_shifts"), shifts)
|
|
664
|
+
)
|
|
665
|
+
# After the line above, so that a refused network has no results to answer from
|
|
666
|
+
self.check_names()
|
|
667
|
+
|
|
668
|
+
try:
|
|
669
|
+
# pandapower raises LoadflowNotConverged instead of returning a non-converged
|
|
670
|
+
# network.
|
|
671
|
+
# A warm start must not make a network fail that a cold one solves, so a
|
|
672
|
+
# failed one is retried from scratch, but only on the network the caller
|
|
673
|
+
# asked to solve: once the controllers have acted (tap positions,
|
|
674
|
+
# setpoints), a failure is final. With controllers, the warm start is
|
|
675
|
+
# therefore first tried without them, at the cost of one more run, which
|
|
676
|
+
# starts at the solution.
|
|
677
|
+
controlled = warm_start and self._controllers_act()
|
|
678
|
+
try:
|
|
679
|
+
self._run_pandapower(warm_start, with_controllers=not controlled)
|
|
680
|
+
except pp.LoadflowNotConverged:
|
|
681
|
+
# Not ControllerNotConverged: a failed controller loop has already
|
|
682
|
+
# changed the network.
|
|
683
|
+
if not warm_start:
|
|
684
|
+
raise
|
|
685
|
+
self.logger.info("Warm-started power flow failed, solving from scratch")
|
|
686
|
+
warm_start = False
|
|
687
|
+
self._run_pandapower(warm_start)
|
|
688
|
+
else:
|
|
689
|
+
if controlled:
|
|
690
|
+
self._run_pandapower(warm_start)
|
|
691
|
+
|
|
692
|
+
residual = self._take_one_more_newton_step()
|
|
693
|
+
if residual is None:
|
|
694
|
+
# No step: the solver's own bound
|
|
695
|
+
residual = self.pf_settings["generic"]["tolerance"]
|
|
696
|
+
|
|
697
|
+
# Store results for later use
|
|
698
|
+
self.latest_results = {
|
|
699
|
+
"converged": self.network.converged,
|
|
700
|
+
"iterations": self.network._ppc.get("iterations", None),
|
|
701
|
+
"time": self.network._ppc.get("et", 0.0), # execution time
|
|
702
|
+
# The power mismatch left at a bus, MVA (see `unresolved_power_mva`)
|
|
703
|
+
"unresolved_mva": float(residual) * float(self.network.sn_mva),
|
|
704
|
+
# What the solution was solved with, for the next warm start: it comes
|
|
705
|
+
# back with the results when a network is put back with them
|
|
706
|
+
"_phase_shifts": shifts,
|
|
707
|
+
}
|
|
708
|
+
|
|
709
|
+
self.logger.info(
|
|
710
|
+
f"Power flow calculation finished: converged={self.network.converged}, "
|
|
711
|
+
f"iterations={self.latest_results['iterations']}"
|
|
712
|
+
)
|
|
713
|
+
|
|
714
|
+
return self.latest_results
|
|
715
|
+
|
|
716
|
+
except (pp.LoadflowNotConverged, pp.ControllerNotConverged) as e:
|
|
717
|
+
# ControllerNotConverged comes from `run_control=True` in the power flow
|
|
718
|
+
# settings; it is a sibling of LoadflowNotConverged, not a subclass.
|
|
719
|
+
self.logger.warning(f"Power flow did not converge: {str(e)}")
|
|
720
|
+
error = (
|
|
721
|
+
PandaPowerControllerNotConverged
|
|
722
|
+
if isinstance(e, pp.ControllerNotConverged)
|
|
723
|
+
else PandaPowerNotConverged
|
|
724
|
+
)
|
|
725
|
+
raise error(str(e)) from e
|
|
726
|
+
|
|
727
|
+
except Exception as e:
|
|
728
|
+
self.logger.error(f"Power flow calculation failed: {str(e)}")
|
|
729
|
+
raise
|
|
730
|
+
|
|
731
|
+
def _has_solution(self, results: dict[str, Any] | None = None) -> bool:
|
|
732
|
+
"""
|
|
733
|
+
Tell whether the result tables hold a converged solution of every bus of this network.
|
|
734
|
+
|
|
735
|
+
A converged run leaves NaN voltages at the buses it found isolated. If a strategy
|
|
736
|
+
has since reconnected one, a warm start would start Newton from NaN and fail.
|
|
737
|
+
|
|
738
|
+
Args:
|
|
739
|
+
results: The results of the run that left the tables, `latest_results`
|
|
740
|
+
if not given.
|
|
741
|
+
"""
|
|
742
|
+
net = self.network
|
|
743
|
+
results = self.latest_results if results is None else results
|
|
744
|
+
return bool(
|
|
745
|
+
net is not None
|
|
746
|
+
and results
|
|
747
|
+
and results.get("converged")
|
|
748
|
+
and net.res_bus.index.equals(net.bus.index)
|
|
749
|
+
and not net.res_bus[["vm_pu", "va_degree"]].isna().to_numpy().any()
|
|
750
|
+
)
|
|
751
|
+
|
|
752
|
+
# The elements that apply an angle, with the columns of the angle they apply: the
|
|
753
|
+
# transformers, the three-winding transformers, and the external grids
|
|
754
|
+
_ANGLE_ELEMENTS = (
|
|
755
|
+
("trafo", ("shift_degree",)),
|
|
756
|
+
("trafo3w", ("shift_mv_degree", "shift_lv_degree")),
|
|
757
|
+
("ext_grid", ("va_degree",)),
|
|
758
|
+
)
|
|
759
|
+
|
|
760
|
+
def _phase_shifts(self) -> tuple:
|
|
761
|
+
"""
|
|
762
|
+
What the angles of the voltages of the next run are set by, to tell whether
|
|
763
|
+
the previous solution is a start for it:
|
|
764
|
+
|
|
765
|
+
- whether the power flow calculates the angles at all
|
|
766
|
+
(``calculate_voltage_angles``);
|
|
767
|
+
- what connects the network and supplies it (`_topology_key`): the service
|
|
768
|
+
state of the buses, lines, transformers, impedances, DC lines and sources,
|
|
769
|
+
the buses each joins, the state of every switch, which generator is the
|
|
770
|
+
slack;
|
|
771
|
+
- for each transformer, three-winding transformer and external grid, keyed by
|
|
772
|
+
its index, the angle it applies (``shift_degree``, ``shift_mv_degree`` and
|
|
773
|
+
``shift_lv_degree``, ``va_degree``) and, for a transformer whose tap adds an
|
|
774
|
+
angle (`_tap_angle_rows`), every column of its tap changer (``tap_*``,
|
|
775
|
+
``tap2_*``, ``id_characteristic_table``).
|
|
776
|
+
|
|
777
|
+
Missing values are None, so that the values, in tuples and dictionaries,
|
|
778
|
+
compare as values, and results that hold them do as well.
|
|
779
|
+
|
|
780
|
+
A change of the angle an element applies rotates the voltages of every bus
|
|
781
|
+
beyond it by that angle, and a change of what connects them can move buses
|
|
782
|
+
behind a source of another angle: the previous solution, rotated, is the new
|
|
783
|
+
one. Newton-Raphson started from the previous solution unrotated starts that
|
|
784
|
+
far from it, 30 to 180 degrees for a change of vector group, and can converge to
|
|
785
|
+
another solution of the power flow equations: on a 1.6 MVA unit loaded at
|
|
786
|
+
75 %, it reached one at 0.05 p.u. after a change of its shift by 90 or 180
|
|
787
|
+
degrees (and failed at 120 and 150), and on a three-winding transformer one at
|
|
788
|
+
0.06 p.u. after 60 degrees (#56). The same happened when the supply moved to a
|
|
789
|
+
unit of another shift (in service, terminal switches), a feeder to a substation
|
|
790
|
+
of another shift (lines in and out of service, line or bus switches), and when
|
|
791
|
+
an ideal phase shifter of 5 degrees a step moved 10 steps at once. A warm start
|
|
792
|
+
is therefore not made after any change of what this gives (`run_power_flow`),
|
|
793
|
+
whatever the angle: no rule tells from the angle alone which start converges
|
|
794
|
+
where, and a cold start is always right. The inputs of the angles are compared,
|
|
795
|
+
not the angles pandapower computes from them, which only a run gives: a change
|
|
796
|
+
of them that turns the voltages little also starts from scratch. No strategy
|
|
797
|
+
changes the topology or the angles: their warm starts are kept.
|
|
798
|
+
|
|
799
|
+
Not seen: a change of the characteristic table of a tabular tap changer
|
|
800
|
+
(``trafo_characteristic_table``), whose rows are not compared.
|
|
801
|
+
"""
|
|
802
|
+
net = self.network
|
|
803
|
+
angles = [
|
|
804
|
+
self.pf_settings["specific"].get("calculate_voltage_angles", True),
|
|
805
|
+
self._topology_key(),
|
|
806
|
+
]
|
|
807
|
+
for element, columns in self._ANGLE_ELEMENTS:
|
|
808
|
+
table = getattr(net, element, None)
|
|
809
|
+
angles.append(
|
|
810
|
+
{}
|
|
811
|
+
if table is None or not len(table)
|
|
812
|
+
else self._applied_angles(table, columns)
|
|
813
|
+
)
|
|
814
|
+
return tuple(angles)
|
|
815
|
+
|
|
816
|
+
@classmethod
|
|
817
|
+
def _applied_angles(cls, table: pd.DataFrame, columns: tuple[str, ...]) -> dict:
|
|
818
|
+
"""
|
|
819
|
+
The `columns` of each element of `table`, by index, with the columns of the
|
|
820
|
+
tap changer of those whose tap adds an angle (see `_phase_shifts`).
|
|
821
|
+
"""
|
|
822
|
+
names = set(table.columns)
|
|
823
|
+
rows = list(
|
|
824
|
+
zip(
|
|
825
|
+
*(cls._plain(table[column]) for column in columns if column in names),
|
|
826
|
+
strict=True,
|
|
827
|
+
)
|
|
828
|
+
)
|
|
829
|
+
tap = cls._tap_angle_rows(table, names)
|
|
830
|
+
if tap.any():
|
|
831
|
+
tap_rows = list(
|
|
832
|
+
zip(
|
|
833
|
+
*(
|
|
834
|
+
cls._plain(table[column])
|
|
835
|
+
for column in table.columns
|
|
836
|
+
if column.startswith("tap")
|
|
837
|
+
or column == "id_characteristic_table"
|
|
838
|
+
),
|
|
839
|
+
strict=True,
|
|
840
|
+
)
|
|
841
|
+
)
|
|
842
|
+
rows = [
|
|
843
|
+
row + tap_row if with_tap else row
|
|
844
|
+
for row, tap_row, with_tap in zip(rows, tap_rows, tap, strict=True)
|
|
845
|
+
]
|
|
846
|
+
return dict(zip(table.index.tolist(), rows, strict=True))
|
|
847
|
+
|
|
848
|
+
@staticmethod
|
|
849
|
+
def _tap_angle_rows(table: pd.DataFrame, names: set[str]) -> np.ndarray:
|
|
850
|
+
"""
|
|
851
|
+
Which transformers of `table` have a tap that adds an angle to their shift:
|
|
852
|
+
pandapower's ideal phase shifters (``tap_changer_type`` "Ideal"), tap changers
|
|
853
|
+
of another type whose step has an angle (``tap_step_degree`` other than 0 and
|
|
854
|
+
NaN), tabular ones (``tap_dependency_table``), and those of the former
|
|
855
|
+
``tap_phase_shifter`` flag; for the second tap changer (``tap2_*``) as well. A
|
|
856
|
+
ratio tap changer of no angle, as those of the MV/LV feeders, is not one: its
|
|
857
|
+
tap moves the voltages a little, and does not rotate them.
|
|
858
|
+
"""
|
|
859
|
+
rows = np.zeros(len(table), dtype=bool)
|
|
860
|
+
for tap in ("tap", "tap2"):
|
|
861
|
+
if f"{tap}_changer_type" in names:
|
|
862
|
+
kinds = table[f"{tap}_changer_type"].to_numpy(dtype=object)
|
|
863
|
+
rows |= kinds == "Ideal"
|
|
864
|
+
if f"{tap}_step_degree" in names:
|
|
865
|
+
degrees = table[f"{tap}_step_degree"].to_numpy(
|
|
866
|
+
dtype=float, na_value=np.nan
|
|
867
|
+
)
|
|
868
|
+
# Not 0, not NaN
|
|
869
|
+
stepped = (degrees != 0.0) & (degrees == degrees)
|
|
870
|
+
if stepped.any():
|
|
871
|
+
rows |= stepped & pd.notna(kinds)
|
|
872
|
+
for flag in (f"{tap}_dependency_table", f"{tap}_phase_shifter"):
|
|
873
|
+
if flag in names:
|
|
874
|
+
rows |= table[flag].to_numpy(dtype=object) == True # noqa: E712
|
|
875
|
+
return rows
|
|
876
|
+
|
|
877
|
+
@staticmethod
|
|
878
|
+
def _plain(column: pd.Series) -> list:
|
|
879
|
+
"""
|
|
880
|
+
The values of `column` as Python values, None for a missing one (NaN, None,
|
|
881
|
+
pd.NA, NaT) whatever its type, nullable extension types included: pd.NA
|
|
882
|
+
cannot be compared.
|
|
883
|
+
"""
|
|
884
|
+
dtype = column.dtype
|
|
885
|
+
if isinstance(dtype, np.dtype) and dtype.kind in "iub":
|
|
886
|
+
return column.tolist()
|
|
887
|
+
if isinstance(dtype, np.dtype) and dtype.kind == "f":
|
|
888
|
+
values = column.to_numpy()
|
|
889
|
+
plain = values.tolist()
|
|
890
|
+
if np.isnan(values).any():
|
|
891
|
+
plain = [None if v != v else v for v in plain]
|
|
892
|
+
return plain
|
|
893
|
+
missing = column.isna().to_numpy(dtype=bool)
|
|
894
|
+
plain = column.tolist()
|
|
895
|
+
if missing.any():
|
|
896
|
+
plain = [
|
|
897
|
+
None if gone else v for v, gone in zip(plain, missing, strict=True)
|
|
898
|
+
]
|
|
899
|
+
return plain
|
|
900
|
+
|
|
901
|
+
def _same_phase_shifts(self, solved: tuple | None, current: tuple) -> bool:
|
|
902
|
+
"""
|
|
903
|
+
Tell whether the angles a solution was `solved` with (`_phase_shifts`) are the
|
|
904
|
+
`current` ones, exactly. A solution whose angles are not known, as one of
|
|
905
|
+
another version of the engine, or that cannot be compared with them, is taken
|
|
906
|
+
for one with others: it is not started from. A comparison that fails is
|
|
907
|
+
reported, since every run would then start from scratch without a word.
|
|
908
|
+
"""
|
|
909
|
+
if solved is None:
|
|
910
|
+
return False
|
|
911
|
+
try:
|
|
912
|
+
return bool(solved == current)
|
|
913
|
+
except (TypeError, ValueError) as error:
|
|
914
|
+
self.logger.warning(
|
|
915
|
+
"The angles of the previous solution cannot be compared with those of "
|
|
916
|
+
f"the network ({error}): the power flow starts from scratch"
|
|
917
|
+
)
|
|
918
|
+
return False
|
|
919
|
+
|
|
920
|
+
def check_names(self) -> None:
|
|
921
|
+
"""
|
|
922
|
+
Refuse a network in which a bus, a line, a transformer, a load or a static
|
|
923
|
+
generator has no name, or the name of another element of its table.
|
|
924
|
+
|
|
925
|
+
Everything the engine answers by name would otherwise silently mix them up: the
|
|
926
|
+
sensitivities give one row for two buses, a parallel conductor goes on two lines
|
|
927
|
+
at once, a line to a bus named as the source of the feeder is a line to the
|
|
928
|
+
source in the path search. Elements without a name (None, NaN or "") cannot be
|
|
929
|
+
told apart either: the voltage sensitivities give all the unnamed buses of a
|
|
930
|
+
network the same name, NaN. Loads and static generators are identified by their
|
|
931
|
+
index, but their flexibility settings are kept by name (`flexibility_settings`):
|
|
932
|
+
two loads of one name would get the same flexibility, whatever was meant for
|
|
933
|
+
each. Elements of different tables may share a name.
|
|
934
|
+
|
|
935
|
+
`run_power_flow` calls it before each run; call it right after loading a network
|
|
936
|
+
to know at once, before any power flow. Nothing is renamed: `fill_missing_names`
|
|
937
|
+
names the elements that have no name, and shared names are for the caller to
|
|
938
|
+
change.
|
|
939
|
+
|
|
940
|
+
Raises:
|
|
941
|
+
ValueError: Giving, for each table, the indices of up to five elements
|
|
942
|
+
without a name, and up to five shared names, each with the indices of
|
|
943
|
+
the elements that have it, or if no network is loaded.
|
|
944
|
+
"""
|
|
945
|
+
if not self.network:
|
|
946
|
+
raise ValueError("No network loaded for power flow calculation")
|
|
947
|
+
|
|
948
|
+
unnamed, shared = [], []
|
|
949
|
+
for element, label in (
|
|
950
|
+
("bus", "buses"),
|
|
951
|
+
("line", "lines"),
|
|
952
|
+
("trafo", "transformers"),
|
|
953
|
+
("load", "loads"),
|
|
954
|
+
("sgen", "static generators"),
|
|
955
|
+
):
|
|
956
|
+
table = getattr(self.network, element, None)
|
|
957
|
+
if table is None or table.empty:
|
|
958
|
+
continue
|
|
959
|
+
if "name" not in table.columns:
|
|
960
|
+
unnamed.append(f"{label}: all {len(table)}, which have no name column")
|
|
961
|
+
continue
|
|
962
|
+
column = table["name"]
|
|
963
|
+
values = column.to_numpy()
|
|
964
|
+
names = set(values.tolist())
|
|
965
|
+
# The quick test, before each power flow, on names that are all strings
|
|
966
|
+
# (no None, no NaN): 0.23 ms for the five tables of the case-study feeder
|
|
967
|
+
# with the most loads (2,470; 0.09 ms of it for them), against 13 ms for
|
|
968
|
+
# one of its warm power flows
|
|
969
|
+
if (
|
|
970
|
+
len(names) == len(values)
|
|
971
|
+
and "" not in names
|
|
972
|
+
and infer_dtype(values, skipna=False) == "string"
|
|
973
|
+
):
|
|
974
|
+
continue
|
|
975
|
+
missing = column.isna() | (column == "")
|
|
976
|
+
if missing.any():
|
|
977
|
+
where = [str(index) for index in column.index[missing]]
|
|
978
|
+
listed = ", ".join(where[:5])
|
|
979
|
+
if len(where) > 5:
|
|
980
|
+
listed += f" and {len(where) - 5} more"
|
|
981
|
+
unnamed.append(f"{label}: {listed}")
|
|
982
|
+
present = column[~missing]
|
|
983
|
+
repeated = present[present.duplicated(keep=False)]
|
|
984
|
+
if repeated.empty:
|
|
985
|
+
continue
|
|
986
|
+
indices: dict[Any, list[str]] = {}
|
|
987
|
+
for index, name in repeated.items():
|
|
988
|
+
indices.setdefault(name, []).append(str(index))
|
|
989
|
+
listed = "; ".join(
|
|
990
|
+
f"{name!r} ({', '.join(where)})"
|
|
991
|
+
for name, where in list(indices.items())[:5]
|
|
992
|
+
)
|
|
993
|
+
if len(indices) > 5:
|
|
994
|
+
listed += f"; and {len(indices) - 5} more"
|
|
995
|
+
shared.append(f"{label}: {listed}")
|
|
996
|
+
if unnamed or shared:
|
|
997
|
+
problems = []
|
|
998
|
+
if unnamed:
|
|
999
|
+
problems.append(
|
|
1000
|
+
"Elements without a name (None, NaN or ''), by index: "
|
|
1001
|
+
+ ". ".join(unnamed)
|
|
1002
|
+
+ ". `PandaPowerEngine.fill_missing_names()` names them."
|
|
1003
|
+
)
|
|
1004
|
+
if shared:
|
|
1005
|
+
problems.append(
|
|
1006
|
+
"Names shared, with the indices of the elements that have them: "
|
|
1007
|
+
+ ". ".join(shared)
|
|
1008
|
+
+ "."
|
|
1009
|
+
)
|
|
1010
|
+
raise ValueError(
|
|
1011
|
+
"Buses, lines and transformers are identified by their name, and the "
|
|
1012
|
+
"flexibility settings of loads and static generators are kept by it: "
|
|
1013
|
+
"each must have one and not share it with another element of its "
|
|
1014
|
+
"table. " + " ".join(problems)
|
|
1015
|
+
)
|
|
1016
|
+
|
|
1017
|
+
def _has_converged_results(self) -> bool:
|
|
1018
|
+
"""
|
|
1019
|
+
Tell whether the last run of the engine converged, for the sensitivities, which
|
|
1020
|
+
read its results.
|
|
1021
|
+
|
|
1022
|
+
Both flags are needed: `latest_results["converged"]` is False after any failed
|
|
1023
|
+
run, but pandapower leaves `net.converged` True when it is the controllers that
|
|
1024
|
+
do not converge, and it is False for a network that was never solved.
|
|
1025
|
+
|
|
1026
|
+
`latest_results` is set by `run_power_flow` and forgotten when a network is
|
|
1027
|
+
assigned, so the results of a power flow run outside the engine (`pp.runpp`,
|
|
1028
|
+
then the network assigned to the engine) are refused: whether their controllers
|
|
1029
|
+
converged is not known, and their network has not been through `check_names`,
|
|
1030
|
+
without which the sensitivities can name two buses alike. `check_violations`
|
|
1031
|
+
refuses them as well. A network put back with results of the engine's own run
|
|
1032
|
+
(`latest_results` assigned after it, as the snapshots of the algorithm do) is
|
|
1033
|
+
accepted.
|
|
1034
|
+
"""
|
|
1035
|
+
net = self.network
|
|
1036
|
+
return bool(
|
|
1037
|
+
net is not None
|
|
1038
|
+
and net.converged
|
|
1039
|
+
and self.latest_results
|
|
1040
|
+
and self.latest_results.get("converged")
|
|
1041
|
+
)
|
|
1042
|
+
|
|
1043
|
+
def _tables_match_results(self) -> bool:
|
|
1044
|
+
"""
|
|
1045
|
+
Tell whether the buses, lines and transformers are those of the last run.
|
|
1046
|
+
|
|
1047
|
+
The sensitivities read the Jacobian and the result tables of the last run, and
|
|
1048
|
+
find a bus or a branch in them by its place in the element tables. After a bus
|
|
1049
|
+
or a line has been created or dropped without a new run, the same place is
|
|
1050
|
+
another element, or none. Two things are compared, which a run leaves in the
|
|
1051
|
+
network itself, so that a network put back together with the results of a run
|
|
1052
|
+
of the engine (`latest_results` assigned after it) is checked as well; the
|
|
1053
|
+
results of a power flow run outside the engine are refused before, by
|
|
1054
|
+
`_has_converged_results`:
|
|
1055
|
+
|
|
1056
|
+
- the index of the element tables with that of the result tables, which a
|
|
1057
|
+
creation does not extend, and a drop with pandas (not `pp.drop_*`) does not
|
|
1058
|
+
shorten;
|
|
1059
|
+
- the number of lines and of transformers with the number of branches of each
|
|
1060
|
+
that the run solved, which `pp.drop_*` changes in both tables.
|
|
1061
|
+
|
|
1062
|
+
A line dropped with pandas and then a new one created at its index, or a bus
|
|
1063
|
+
without any branch dropped, pass this check.
|
|
1064
|
+
"""
|
|
1065
|
+
net = self.network
|
|
1066
|
+
for element in ("bus", "line", "trafo"):
|
|
1067
|
+
if not getattr(net, element).index.equals(
|
|
1068
|
+
getattr(net, f"res_{element}").index
|
|
1069
|
+
):
|
|
1070
|
+
return False
|
|
1071
|
+
solved = (getattr(net, "_pd2ppc_lookups", None) or {}).get("branch", {})
|
|
1072
|
+
return all(
|
|
1073
|
+
len(getattr(net, element)) == (solved[element][1] - solved[element][0])
|
|
1074
|
+
if element in solved
|
|
1075
|
+
else len(getattr(net, element)) == 0
|
|
1076
|
+
for element in ("line", "trafo")
|
|
1077
|
+
)
|
|
1078
|
+
|
|
1079
|
+
def _converged_jacobian(self) -> sparse.csr_matrix | None:
|
|
1080
|
+
"""
|
|
1081
|
+
Get the Jacobian of the power flow equations at the solution of the last run,
|
|
1082
|
+
after the Newton step that ends it (`_take_one_more_newton_step`).
|
|
1083
|
+
|
|
1084
|
+
The sensitivities need it. pandapower keeps the Jacobian of its last Newton
|
|
1085
|
+
step, built before the final voltage update, and none at all when the run
|
|
1086
|
+
starts within tolerance, as a warm start can. The sensitivities would then
|
|
1087
|
+
depend on where the run started, and so would the decisions of the strategies.
|
|
1088
|
+
|
|
1089
|
+
Returns:
|
|
1090
|
+
Optional[sparse.csr_matrix]: The Jacobian, None if no run left a solution.
|
|
1091
|
+
|
|
1092
|
+
Raises:
|
|
1093
|
+
NotImplementedError: If the power flow uses a distributed slack, whose
|
|
1094
|
+
Jacobian has an extra row and column that the sensitivities do not handle.
|
|
1095
|
+
"""
|
|
1096
|
+
if self.pf_settings["specific"].get("distributed_slack", False):
|
|
1097
|
+
raise NotImplementedError(
|
|
1098
|
+
"Sensitivities are not available with a distributed slack"
|
|
1099
|
+
)
|
|
1100
|
+
ppc = getattr(self.network, "_ppc", None) or {}
|
|
1101
|
+
internal = ppc.get("internal", {})
|
|
1102
|
+
voltages = internal.get("V")
|
|
1103
|
+
if voltages is None:
|
|
1104
|
+
return None
|
|
1105
|
+
if self._jacobian_cache is None or self._jacobian_cache[0] is not voltages:
|
|
1106
|
+
self._jacobian_cache = (voltages, self._jacobian_at(internal, voltages))
|
|
1107
|
+
return self._jacobian_cache[1]
|
|
1108
|
+
|
|
1109
|
+
@staticmethod
|
|
1110
|
+
def _jacobian_at(
|
|
1111
|
+
internal: dict[str, Any], voltages: np.ndarray
|
|
1112
|
+
) -> sparse.csr_matrix:
|
|
1113
|
+
"""
|
|
1114
|
+
The Jacobian of the power flow equations of `internal` at `voltages`.
|
|
1115
|
+
|
|
1116
|
+
Built by pandapower's numba builder, which its Newton-Raphson has compiled,
|
|
1117
|
+
15 to 20 times faster than its Python one, which gives the same matrix and is
|
|
1118
|
+
used where numba is not available.
|
|
1119
|
+
"""
|
|
1120
|
+
# Private to pandapower, so imported here: if a release changes it, only the
|
|
1121
|
+
# sensitivities break, not the whole engine.
|
|
1122
|
+
from pandapower.pf.create_jacobian import (
|
|
1123
|
+
_create_J_with_numba,
|
|
1124
|
+
_create_J_without_numba,
|
|
1125
|
+
get_fastest_jacobian_function,
|
|
1126
|
+
)
|
|
1127
|
+
|
|
1128
|
+
pv = np.asarray(internal["pv"], dtype=int)
|
|
1129
|
+
pq = np.asarray(internal["pq"], dtype=int)
|
|
1130
|
+
ref = np.asarray(internal["ref"], dtype=int)
|
|
1131
|
+
pvpq = np.r_[pv, pq]
|
|
1132
|
+
admittances = internal["Ybus"].tocsr()
|
|
1133
|
+
try:
|
|
1134
|
+
build = get_fastest_jacobian_function(pvpq, pq, True, False)
|
|
1135
|
+
lookup = np.zeros(int(admittances.indices.max()) + 1, dtype=np.int64)
|
|
1136
|
+
lookup[pvpq] = np.arange(len(pvpq))
|
|
1137
|
+
return _create_J_with_numba(
|
|
1138
|
+
admittances,
|
|
1139
|
+
voltages,
|
|
1140
|
+
np.r_[ref, pvpq],
|
|
1141
|
+
pvpq,
|
|
1142
|
+
pq,
|
|
1143
|
+
build,
|
|
1144
|
+
lookup,
|
|
1145
|
+
len(ref),
|
|
1146
|
+
len(pv),
|
|
1147
|
+
len(pq),
|
|
1148
|
+
None,
|
|
1149
|
+
False,
|
|
1150
|
+
).tocsr()
|
|
1151
|
+
except (ImportError, NameError, TypeError, ValueError):
|
|
1152
|
+
return _create_J_without_numba(
|
|
1153
|
+
admittances, voltages, ref, pvpq, pq, None, False
|
|
1154
|
+
).tocsr()
|
|
1155
|
+
|
|
1156
|
+
@staticmethod
|
|
1157
|
+
def _load_voltage_derivative(
|
|
1158
|
+
internal: dict[str, Any], magnitudes: np.ndarray, n_pv: int, pq: np.ndarray
|
|
1159
|
+
) -> sparse.csr_matrix:
|
|
1160
|
+
"""
|
|
1161
|
+
What the voltage-dependent loads add to the Jacobian of the power mismatch, in
|
|
1162
|
+
the columns of the voltage magnitudes of the PQ buses.
|
|
1163
|
+
|
|
1164
|
+
pandapower takes a load at the voltage `v` as ``P (cp + ci v + cz v^2)`` (and
|
|
1165
|
+
the same for Q with its own shares), ``ci`` and ``cz`` being the shares of
|
|
1166
|
+
constant current and constant impedance at the bus (``CID_*`` and ``CZD_*`` of
|
|
1167
|
+
the internal bus table). The mismatch is the power the network draws minus the
|
|
1168
|
+
injections, the generation less the loads, so its derivative with respect to
|
|
1169
|
+
`v` gains ``P (ci + 2 cz v)`` and ``Q (ci_q + 2 cz_q v)``, in per unit of the
|
|
1170
|
+
base power, on the diagonal of the bus. Zero for loads of constant power.
|
|
1171
|
+
"""
|
|
1172
|
+
from pandapower.pypower.idx_bus import CID_P, CID_Q, CZD_P, CZD_Q, PD, QD
|
|
1173
|
+
|
|
1174
|
+
bus = internal["bus"]
|
|
1175
|
+
base = float(np.real(internal["baseMVA"]))
|
|
1176
|
+
v = magnitudes[pq]
|
|
1177
|
+
p = np.real(bus[pq, PD]) * (
|
|
1178
|
+
np.real(bus[pq, CID_P]) + 2.0 * np.real(bus[pq, CZD_P]) * v
|
|
1179
|
+
)
|
|
1180
|
+
q = np.real(bus[pq, QD]) * (
|
|
1181
|
+
np.real(bus[pq, CID_Q]) + 2.0 * np.real(bus[pq, CZD_Q]) * v
|
|
1182
|
+
)
|
|
1183
|
+
n_pvpq = n_pv + len(pq)
|
|
1184
|
+
size = n_pvpq + len(pq)
|
|
1185
|
+
columns = n_pvpq + np.arange(len(pq))
|
|
1186
|
+
rows = np.r_[n_pv + np.arange(len(pq)), columns]
|
|
1187
|
+
return sparse.csr_matrix(
|
|
1188
|
+
(np.r_[p, q] / base, (rows, np.r_[columns, columns])), shape=(size, size)
|
|
1189
|
+
)
|
|
1190
|
+
|
|
1191
|
+
def _jacobian_lu(self, jacobian: sparse.csr_matrix) -> Any:
|
|
1192
|
+
"""
|
|
1193
|
+
LU factors of the Jacobian, computed once per solution.
|
|
1194
|
+
|
|
1195
|
+
Both J x = b and J^T y = c are solved from them (``solve(c, trans="T")``), so the
|
|
1196
|
+
sensitivities need one factorisation, however many of them are asked for.
|
|
1197
|
+
"""
|
|
1198
|
+
if (
|
|
1199
|
+
self._jacobian_lu_cache is None
|
|
1200
|
+
or self._jacobian_lu_cache[0] is not jacobian
|
|
1201
|
+
):
|
|
1202
|
+
self._jacobian_lu_cache = (jacobian, splu(jacobian.tocsc()))
|
|
1203
|
+
return self._jacobian_lu_cache[1]
|
|
1204
|
+
|
|
1205
|
+
def _ppc_bus_names(
|
|
1206
|
+
self, ppc_indices: np.ndarray, missing: str | None = "unknown"
|
|
1207
|
+
) -> list[tuple[int, str]]:
|
|
1208
|
+
"""
|
|
1209
|
+
Name the internal (ppc) buses at `ppc_indices`, as (position, name) pairs.
|
|
1210
|
+
|
|
1211
|
+
Buses that pandapower merges into one internal bus (joined by a closed bus-bus
|
|
1212
|
+
switch) all map to it: each gives a pair with the position of that internal
|
|
1213
|
+
bus, in the order of the bus table. A ppc bus with no bus of the network is
|
|
1214
|
+
named ``f"{missing}_{index}"``, or left out if `missing` is None.
|
|
1215
|
+
"""
|
|
1216
|
+
net = self.network
|
|
1217
|
+
bus_lookup = net._pd2ppc_lookups["bus"]
|
|
1218
|
+
names_of: dict[int, list[str]] = {}
|
|
1219
|
+
for pd_idx, name in zip(net.bus.index, net.bus["name"], strict=True):
|
|
1220
|
+
if isinstance(bus_lookup, np.ndarray):
|
|
1221
|
+
ppc = bus_lookup[pd_idx] if 0 <= pd_idx < len(bus_lookup) else -1
|
|
1222
|
+
else:
|
|
1223
|
+
ppc = bus_lookup.get(pd_idx, -1)
|
|
1224
|
+
# Buses out of service have no internal bus (-1)
|
|
1225
|
+
if ppc >= 0:
|
|
1226
|
+
names_of.setdefault(int(ppc), []).append(name)
|
|
1227
|
+
result = []
|
|
1228
|
+
for position, ppc in enumerate(ppc_indices):
|
|
1229
|
+
names = names_of.get(int(ppc))
|
|
1230
|
+
if names is not None:
|
|
1231
|
+
result.extend((position, name) for name in names)
|
|
1232
|
+
elif missing is not None:
|
|
1233
|
+
result.append((position, f"{missing}_{ppc}"))
|
|
1234
|
+
return result
|
|
1235
|
+
|
|
1236
|
+
def _controllers_act(self) -> bool:
|
|
1237
|
+
"""Tell whether a power flow also runs controllers, which change the network."""
|
|
1238
|
+
controllers = getattr(self.network, "controller", None)
|
|
1239
|
+
return bool(
|
|
1240
|
+
self.pf_settings["specific"].get("run_control", False)
|
|
1241
|
+
and controllers is not None
|
|
1242
|
+
and len(controllers)
|
|
1243
|
+
and controllers["in_service"].any()
|
|
1244
|
+
)
|
|
1245
|
+
|
|
1246
|
+
def _run_pandapower(self, warm_start: bool, with_controllers: bool = True) -> None:
|
|
1247
|
+
"""
|
|
1248
|
+
Run pandapower's power flow with the settings of the engine.
|
|
1249
|
+
|
|
1250
|
+
Args:
|
|
1251
|
+
warm_start (bool): Start from the results of the previous run.
|
|
1252
|
+
with_controllers (bool): If False, do not run the controllers, whatever
|
|
1253
|
+
`run_control` in the settings.
|
|
1254
|
+
"""
|
|
1255
|
+
specific = dict(self.pf_settings["specific"])
|
|
1256
|
+
if not with_controllers:
|
|
1257
|
+
specific["run_control"] = False
|
|
1258
|
+
# pandapower's keyword name: its value is per unit of sn_mva, not MVA
|
|
1259
|
+
tolerance = self.pf_settings["generic"]["tolerance"]
|
|
1260
|
+
pp.runpp(
|
|
1261
|
+
self.network,
|
|
1262
|
+
max_iteration=self.pf_settings["generic"]["max_iterations"],
|
|
1263
|
+
tolerance_mva=tolerance,
|
|
1264
|
+
init="results" if warm_start else "auto",
|
|
1265
|
+
**specific,
|
|
1266
|
+
)
|
|
1267
|
+
|
|
1268
|
+
def unresolved_power_mva(self) -> float | None:
|
|
1269
|
+
"""
|
|
1270
|
+
The largest power mismatch, in MVA, that the last run left at a bus: the power
|
|
1271
|
+
that its solution does not resolve.
|
|
1272
|
+
|
|
1273
|
+
After the Newton step that ends a run (`_take_one_more_newton_step`), the
|
|
1274
|
+
rounding floor of the power balance at its solution (`_rounding_floor`), an
|
|
1275
|
+
upper bound of what the step leaves: 1.4e-11 to 3.5e-9 MVA on the MV/LV
|
|
1276
|
+
feeders at the load of the case study, whatever the tolerance. Where no step
|
|
1277
|
+
is taken, the bound of the solver, which
|
|
1278
|
+
compares the mismatch with its tolerance in per unit of the base power of the
|
|
1279
|
+
network, `sn_mva`: 1e-6 MVA (1 W) for the default 1e-8 at 100 MVA. None without a
|
|
1280
|
+
converged run of the engine.
|
|
1281
|
+
"""
|
|
1282
|
+
if not self.latest_results or not self.latest_results.get("converged"):
|
|
1283
|
+
return None
|
|
1284
|
+
return self.latest_results.get("unresolved_mva")
|
|
1285
|
+
|
|
1286
|
+
def _take_one_more_newton_step(self) -> float | None:
|
|
1287
|
+
"""
|
|
1288
|
+
End the run with one more Newton step, from the power mismatch the solver left
|
|
1289
|
+
and the Jacobian at its solution, and put the solution after it in the results.
|
|
1290
|
+
|
|
1291
|
+
The solver stops as soon as the power mismatch of every bus is under its
|
|
1292
|
+
tolerance, after a step that may have taken it just under, or far under. What it
|
|
1293
|
+
stops at differs from the exact solution by up to the response of the network
|
|
1294
|
+
to that mismatch, which depends on where the run started: on the MV/LV feeders
|
|
1295
|
+
at 1e-8, warm and cold runs of one network differ by up to 5.2e-6 p.u. of
|
|
1296
|
+
voltage and 3.5e-3 % of loading, and cold runs differ as much from the exact
|
|
1297
|
+
solution. One more step squares that error: the results agree to about 1e-10
|
|
1298
|
+
p.u. whatever the start, and so do the decisions taken on them (#18).
|
|
1299
|
+
|
|
1300
|
+
The step is that of pandapower's Newton-Raphson: the angles of the PV and PQ
|
|
1301
|
+
buses and the magnitudes of the PQ buses, with the injections of the loads at
|
|
1302
|
+
the voltage of the step's start when `voltage_depend_loads` is set. Its
|
|
1303
|
+
Jacobian is that of the sensitivities, plus, in that case, the derivative of the
|
|
1304
|
+
loads with the voltage (`_load_voltage_derivative`), so that the step squares
|
|
1305
|
+
the error with constant-current and constant-impedance loads too. The
|
|
1306
|
+
sensitivities themselves keep the loads at constant power.
|
|
1307
|
+
|
|
1308
|
+
After it, the internal voltages (``_ppc["internal"]["V"]``), from which the
|
|
1309
|
+
sensitivities are computed, the voltages of ``res_bus`` (``vm_pu``,
|
|
1310
|
+
``va_degree``), the currents and loadings of ``res_line`` (``i_from_ka``,
|
|
1311
|
+
``i_to_ka``, ``i_ka``, ``loading_percent``) and of ``res_trafo`` (``i_hv_ka``,
|
|
1312
|
+
``i_lv_ka``, ``loading_percent``) are those of the solution after the step. The
|
|
1313
|
+
other results, the powers, the losses and those of the other elements, are the
|
|
1314
|
+
solver's, and differ from it by no more than the error of the solver.
|
|
1315
|
+
|
|
1316
|
+
Returns:
|
|
1317
|
+
The largest power mismatch the step can leave at a bus, in per unit of
|
|
1318
|
+
the base power: the rounding floor of the power balance at its solution
|
|
1319
|
+
(`_rounding_floor`). None if the step was not taken, and the results are
|
|
1320
|
+
the solver's,
|
|
1321
|
+
with another algorithm than Newton-Raphson (``nr``, ``iwamoto_nr``), with
|
|
1322
|
+
a distributed slack, FACTS devices or line temperatures in the power
|
|
1323
|
+
flow, which the Jacobian of the engine does not model, or if the Jacobian
|
|
1324
|
+
cannot be factorised.
|
|
1325
|
+
"""
|
|
1326
|
+
net = self.network
|
|
1327
|
+
internal = (getattr(net, "_ppc", None) or {}).get("internal", {})
|
|
1328
|
+
voltages = internal.get("V")
|
|
1329
|
+
options = getattr(net, "_options", None) or {}
|
|
1330
|
+
if (
|
|
1331
|
+
voltages is None
|
|
1332
|
+
or not net.converged
|
|
1333
|
+
# The step is that of Newton-Raphson, on the data it leaves: the other
|
|
1334
|
+
# algorithms of pandapower leave other data, or none
|
|
1335
|
+
or options.get("algorithm", "nr") not in ("nr", "iwamoto_nr")
|
|
1336
|
+
or not options.get("ac", True)
|
|
1337
|
+
or self.pf_settings["specific"].get("distributed_slack", False)
|
|
1338
|
+
or options.get("tdpf")
|
|
1339
|
+
or any(
|
|
1340
|
+
len(internal.get(device, ()))
|
|
1341
|
+
for device in ("svc", "tcsc", "ssc", "vsc")
|
|
1342
|
+
)
|
|
1343
|
+
):
|
|
1344
|
+
return None
|
|
1345
|
+
# Private to pandapower, as the Jacobian builder
|
|
1346
|
+
from pandapower.pypower.idx_brch import F_BUS, T_BUS
|
|
1347
|
+
from pandapower.pypower.makeSbus import makeSbus
|
|
1348
|
+
|
|
1349
|
+
pv = np.asarray(internal["pv"], dtype=int)
|
|
1350
|
+
pq = np.asarray(internal["pq"], dtype=int)
|
|
1351
|
+
pvpq = np.r_[pv, pq]
|
|
1352
|
+
magnitudes = np.abs(voltages)
|
|
1353
|
+
injections = makeSbus(
|
|
1354
|
+
internal["baseMVA"],
|
|
1355
|
+
internal["bus"],
|
|
1356
|
+
internal["gen"],
|
|
1357
|
+
vm=magnitudes if options.get("voltage_depend_loads") else None,
|
|
1358
|
+
)
|
|
1359
|
+
mismatch = voltages * np.conj(internal["Ybus"] @ voltages) - injections
|
|
1360
|
+
jacobian = self._jacobian_at(internal, voltages)
|
|
1361
|
+
if options.get("voltage_depend_loads"):
|
|
1362
|
+
jacobian = jacobian + self._load_voltage_derivative(
|
|
1363
|
+
internal, magnitudes, len(pv), pq
|
|
1364
|
+
)
|
|
1365
|
+
try:
|
|
1366
|
+
step = -splu(jacobian.tocsc()).solve(
|
|
1367
|
+
np.r_[mismatch[pvpq].real, mismatch[pq].imag]
|
|
1368
|
+
)
|
|
1369
|
+
except (RuntimeError, ValueError) as error:
|
|
1370
|
+
self.logger.warning(f"No Newton step after the power flow: {error}")
|
|
1371
|
+
return None
|
|
1372
|
+
old_angles = np.angle(voltages)
|
|
1373
|
+
angles = old_angles.copy()
|
|
1374
|
+
angles[pvpq] += step[: len(pvpq)]
|
|
1375
|
+
new_magnitudes = magnitudes.copy()
|
|
1376
|
+
new_magnitudes[pq] += step[len(pvpq) :]
|
|
1377
|
+
stepped = new_magnitudes * np.exp(1j * angles)
|
|
1378
|
+
|
|
1379
|
+
# Branches: what the step multiplies the current, or the apparent power, of
|
|
1380
|
+
# each end by, from the solver's voltages
|
|
1381
|
+
in_service = np.asarray(internal["branch_is"], dtype=bool)
|
|
1382
|
+
position = np.cumsum(in_service) - 1
|
|
1383
|
+
ends = []
|
|
1384
|
+
for admittances, end in (("Yf", F_BUS), ("Yt", T_BUS)):
|
|
1385
|
+
before = np.abs(internal[admittances] @ voltages)
|
|
1386
|
+
after = np.abs(internal[admittances] @ stepped)
|
|
1387
|
+
bus = internal["branch"][:, end].real.astype(int)
|
|
1388
|
+
ends.append((before, after, bus))
|
|
1389
|
+
|
|
1390
|
+
def ratios(element: str, count: int, by_power: bool) -> list[np.ndarray]:
|
|
1391
|
+
"""The factor of each end of the branches of `element`, 1 out of service."""
|
|
1392
|
+
result = [np.ones(count), np.ones(count)]
|
|
1393
|
+
lookups = net._pd2ppc_lookups.get("branch", {})
|
|
1394
|
+
if element not in lookups or count == 0:
|
|
1395
|
+
return result
|
|
1396
|
+
branch = lookups[element][0] + np.arange(count)
|
|
1397
|
+
active = in_service[branch]
|
|
1398
|
+
rows = position[branch[active]]
|
|
1399
|
+
for side, (before, after, bus) in enumerate(ends):
|
|
1400
|
+
old, new = before[rows], after[rows]
|
|
1401
|
+
if by_power:
|
|
1402
|
+
old = old * magnitudes[bus[rows]]
|
|
1403
|
+
new = new * new_magnitudes[bus[rows]]
|
|
1404
|
+
with np.errstate(divide="ignore", invalid="ignore"):
|
|
1405
|
+
factor = np.where(old > 0.0, new / old, 1.0)
|
|
1406
|
+
result[side][active] = factor
|
|
1407
|
+
return result
|
|
1408
|
+
|
|
1409
|
+
def max_of_ends(first, second, ratio) -> np.ndarray:
|
|
1410
|
+
"""The factor of the end that sets the loading, the larger after the step."""
|
|
1411
|
+
first, second = np.nan_to_num(first), np.nan_to_num(second)
|
|
1412
|
+
top = np.maximum(first, second)
|
|
1413
|
+
with np.errstate(divide="ignore", invalid="ignore"):
|
|
1414
|
+
return np.where(
|
|
1415
|
+
top > 0.0,
|
|
1416
|
+
np.maximum(first * ratio[0], second * ratio[1]) / top,
|
|
1417
|
+
1.0,
|
|
1418
|
+
)
|
|
1419
|
+
|
|
1420
|
+
line, trafo = net.res_line, net.res_trafo
|
|
1421
|
+
line_ends = ratios("line", len(line), by_power=False)
|
|
1422
|
+
i_from = line["i_from_ka"].to_numpy(float)
|
|
1423
|
+
i_to = line["i_to_ka"].to_numpy(float)
|
|
1424
|
+
line_factor = max_of_ends(i_from, i_to, line_ends)
|
|
1425
|
+
|
|
1426
|
+
trafo_current = ratios("trafo", len(trafo), by_power=False)
|
|
1427
|
+
if options.get("trafo_loading", "current") == "power":
|
|
1428
|
+
hv = np.hypot(trafo["p_hv_mw"], trafo["q_hv_mvar"]).to_numpy(float)
|
|
1429
|
+
lv = np.hypot(trafo["p_lv_mw"], trafo["q_lv_mvar"]).to_numpy(float)
|
|
1430
|
+
trafo_factor = max_of_ends(
|
|
1431
|
+
hv, lv, ratios("trafo", len(trafo), by_power=True)
|
|
1432
|
+
)
|
|
1433
|
+
else:
|
|
1434
|
+
hv = (trafo["i_hv_ka"] * net.trafo["vn_hv_kv"]).to_numpy(float)
|
|
1435
|
+
lv = (trafo["i_lv_ka"] * net.trafo["vn_lv_kv"]).to_numpy(float)
|
|
1436
|
+
trafo_factor = max_of_ends(hv, lv, trafo_current)
|
|
1437
|
+
|
|
1438
|
+
# Buses: by the lookup of the engine's other methods (see `_ppc_bus_names`)
|
|
1439
|
+
lookup = net._pd2ppc_lookups["bus"]
|
|
1440
|
+
if isinstance(lookup, np.ndarray):
|
|
1441
|
+
index = net.bus.index.to_numpy()
|
|
1442
|
+
inside = (index >= 0) & (index < len(lookup))
|
|
1443
|
+
internal_bus = np.full(len(index), -1)
|
|
1444
|
+
internal_bus[inside] = lookup[index[inside]]
|
|
1445
|
+
else:
|
|
1446
|
+
internal_bus = np.array([lookup.get(i, -1) for i in net.bus.index])
|
|
1447
|
+
vm_pu = net.res_bus["vm_pu"].to_numpy(dtype=float).copy()
|
|
1448
|
+
va_degree = net.res_bus["va_degree"].to_numpy(dtype=float).copy()
|
|
1449
|
+
known = (internal_bus >= 0) & np.isfinite(vm_pu)
|
|
1450
|
+
vm_pu[known] = new_magnitudes[internal_bus[known]]
|
|
1451
|
+
va_degree[known] += np.degrees((angles - old_angles)[internal_bus[known]])
|
|
1452
|
+
net.res_bus["vm_pu"] = vm_pu
|
|
1453
|
+
net.res_bus["va_degree"] = va_degree
|
|
1454
|
+
|
|
1455
|
+
line["i_from_ka"] = i_from * line_ends[0]
|
|
1456
|
+
line["i_to_ka"] = i_to * line_ends[1]
|
|
1457
|
+
# As pandapower: NaN where an end has no current (a line to an island)
|
|
1458
|
+
line["i_ka"] = np.maximum(i_from * line_ends[0], i_to * line_ends[1])
|
|
1459
|
+
line["loading_percent"] = line["loading_percent"].to_numpy(float) * line_factor
|
|
1460
|
+
trafo["i_hv_ka"] = trafo["i_hv_ka"].to_numpy(float) * trafo_current[0]
|
|
1461
|
+
trafo["i_lv_ka"] = trafo["i_lv_ka"].to_numpy(float) * trafo_current[1]
|
|
1462
|
+
trafo["loading_percent"] = (
|
|
1463
|
+
trafo["loading_percent"].to_numpy(float) * trafo_factor
|
|
1464
|
+
)
|
|
1465
|
+
|
|
1466
|
+
# A new array: what is cached for the solver's voltages is not taken for these
|
|
1467
|
+
internal["V"] = stepped
|
|
1468
|
+
|
|
1469
|
+
# What the step leaves: the rounding floor of the power balance at its solution
|
|
1470
|
+
injections = makeSbus(
|
|
1471
|
+
internal["baseMVA"],
|
|
1472
|
+
internal["bus"],
|
|
1473
|
+
internal["gen"],
|
|
1474
|
+
vm=new_magnitudes if options.get("voltage_depend_loads") else None,
|
|
1475
|
+
)
|
|
1476
|
+
return self._rounding_floor(internal["Ybus"], stepped, injections, pvpq)
|
|
1477
|
+
|
|
1478
|
+
@staticmethod
|
|
1479
|
+
def _rounding_floor(
|
|
1480
|
+
admittances: Any, voltages: np.ndarray, injections: np.ndarray, rows: np.ndarray
|
|
1481
|
+
) -> float:
|
|
1482
|
+
"""
|
|
1483
|
+
The largest error, in per unit of the base power, with which the power balance
|
|
1484
|
+
of a bus of `rows` can be computed in floating point at `voltages`.
|
|
1485
|
+
|
|
1486
|
+
The mismatch of bus i, ``V_i conj(sum_j Y_ij V_j) - S_i``, sums the terms of
|
|
1487
|
+
row i of the admittance matrix, and two more for the product with ``V_i`` and
|
|
1488
|
+
the injection. A sum of n products is computed within ``gamma_n`` of the sum of
|
|
1489
|
+
their magnitudes, ``gamma_n = n u / (1 - n u)``, u being the unit roundoff
|
|
1490
|
+
(half the machine epsilon): the error of bus i is at most
|
|
1491
|
+
``gamma_(n_i + 2) (|V_i| sum_j |Y_ij| |V_j| + |S_i|)``. It is a smooth function
|
|
1492
|
+
of the state, not a sample of the noise: the same state reached by a warm or a
|
|
1493
|
+
cold run gives the same floor to 1e-11 relative, where the mismatch measured
|
|
1494
|
+
after the step differed by a factor of up to 2.7. It bounds what the step leaves:
|
|
1495
|
+
on 30 feeders of the MV/LV case study, warm and cold, and up to voltage collapse
|
|
1496
|
+
(0.48 p.u.), the mismatch measured after the step was at most 0.42 of it.
|
|
1497
|
+
"""
|
|
1498
|
+
admittances = admittances.tocsr()
|
|
1499
|
+
magnitudes = np.abs(voltages)
|
|
1500
|
+
terms = magnitudes * (abs(admittances) @ magnitudes) + np.abs(injections)
|
|
1501
|
+
unit = np.finfo(float).eps / 2.0
|
|
1502
|
+
n = np.diff(admittances.indptr) + 2
|
|
1503
|
+
gamma = n * unit / (1.0 - n * unit)
|
|
1504
|
+
return float((gamma * terms)[rows].max(initial=0.0))
|
|
1505
|
+
|
|
1506
|
+
def check_violations(self) -> dict[str, Any]:
|
|
1507
|
+
"""
|
|
1508
|
+
Check if the network violates specified constraints.
|
|
1509
|
+
|
|
1510
|
+
The voltages and loadings checked are those of the result tables, which hold
|
|
1511
|
+
the solution after the Newton step that ends each run
|
|
1512
|
+
(`_take_one_more_newton_step`): the violations, and the decisions taken on them,
|
|
1513
|
+
do not depend on where the solver started or stopped. A value at its limit is
|
|
1514
|
+
not a violation.
|
|
1515
|
+
|
|
1516
|
+
Returns:
|
|
1517
|
+
Dict[str, Any]: Dictionary with constraint violations.
|
|
1518
|
+
"""
|
|
1519
|
+
if (
|
|
1520
|
+
not self.network
|
|
1521
|
+
or not self.latest_results
|
|
1522
|
+
or not self.latest_results.get("converged", False)
|
|
1523
|
+
):
|
|
1524
|
+
raise ValueError("Need a converged power flow solution to check violations")
|
|
1525
|
+
|
|
1526
|
+
bus_data = (
|
|
1527
|
+
self.network.bus[["name", "vn_kv"]]
|
|
1528
|
+
.join(self.network.res_bus[["vm_pu"]])
|
|
1529
|
+
.rename(columns={"name": "bus_id"})
|
|
1530
|
+
)
|
|
1531
|
+
bus_data["voltage_level"] = np.where(bus_data["vn_kv"] <= 1.0, "lv", "mv")
|
|
1532
|
+
|
|
1533
|
+
line_data = (
|
|
1534
|
+
self.network.line[["name"]]
|
|
1535
|
+
.join(self.network.res_line[["loading_percent", "i_ka"]])
|
|
1536
|
+
.rename(columns={"name": "line_id", "i_ka": "current"})
|
|
1537
|
+
)
|
|
1538
|
+
line_data["current"] *= 1000.0 # convert to A
|
|
1539
|
+
|
|
1540
|
+
transformer_data = self.network.trafo[["name"]].join(
|
|
1541
|
+
self.network.res_trafo[["loading_percent", "p_hv_mw", "q_hv_mvar"]]
|
|
1542
|
+
)
|
|
1543
|
+
# Apparent power at the HV side, in VA: transformer ratings (sn_mva) are apparent
|
|
1544
|
+
# powers, so the upgrade sizing must compare like with like.
|
|
1545
|
+
transformer_data["power"] = (
|
|
1546
|
+
np.hypot(transformer_data["p_hv_mw"], transformer_data["q_hv_mvar"]) * 1.0e6
|
|
1547
|
+
)
|
|
1548
|
+
transformer_data = transformer_data[
|
|
1549
|
+
["name", "loading_percent", "power"]
|
|
1550
|
+
].rename(columns={"name": "transformer_id"})
|
|
1551
|
+
|
|
1552
|
+
violations = self.constraints.check_violations(
|
|
1553
|
+
bus_data=bus_data,
|
|
1554
|
+
line_data=line_data,
|
|
1555
|
+
transformer_data=transformer_data,
|
|
1556
|
+
)
|
|
1557
|
+
|
|
1558
|
+
return violations
|
|
1559
|
+
|
|
1560
|
+
def analyze_violations(self):
|
|
1561
|
+
"""
|
|
1562
|
+
Calls the NetworkConstraint analyze_violations method.
|
|
1563
|
+
|
|
1564
|
+
Returns:
|
|
1565
|
+
Any: The summary of violations.
|
|
1566
|
+
"""
|
|
1567
|
+
|
|
1568
|
+
return self.constraints.analyze_violations()
|
|
1569
|
+
|
|
1570
|
+
def _element_index(self, table: str, name: str) -> int:
|
|
1571
|
+
"""
|
|
1572
|
+
Index in the pandapower table `table` ("line" or "trafo") of the element
|
|
1573
|
+
called `name`, which the methods that modify an element resolve it by.
|
|
1574
|
+
|
|
1575
|
+
Raises:
|
|
1576
|
+
ValueError: If no element of the table has that name, or several do (the
|
|
1577
|
+
name check of `run_power_flow` refuses such a network): a modification
|
|
1578
|
+
is never made to the first match, or to all of them.
|
|
1579
|
+
"""
|
|
1580
|
+
label = {"line": "Line", "trafo": "Transformer"}[table]
|
|
1581
|
+
elements = getattr(self.network, table)
|
|
1582
|
+
indices = elements.index[elements.name == name].tolist()
|
|
1583
|
+
if not indices:
|
|
1584
|
+
raise ValueError(f"{label} with name '{name}' not found in the network")
|
|
1585
|
+
if len(indices) > 1:
|
|
1586
|
+
raise ValueError(
|
|
1587
|
+
f"{label} name '{name}' is shared by {len(indices)} elements "
|
|
1588
|
+
f"(indices {', '.join(map(str, indices))}): it does not tell which "
|
|
1589
|
+
"to modify"
|
|
1590
|
+
)
|
|
1591
|
+
return indices[0]
|
|
1592
|
+
|
|
1593
|
+
def apply_tap_change(self, trafo_id: str, tap_pos_shift: int) -> bool:
|
|
1594
|
+
"""
|
|
1595
|
+
Change the tap position of a transformer by a number of steps.
|
|
1596
|
+
|
|
1597
|
+
The shift is applied whole or not at all: a shift that would take the position
|
|
1598
|
+
outside the tap range of the unit (``tap_min`` to ``tap_max``) is refused,
|
|
1599
|
+
from inside the range as well as from its end, and so is any shift of a unit
|
|
1600
|
+
without a range or a position (NaN). A position thus never leaves the range by
|
|
1601
|
+
a tap change; `upgrade_transformer` brings it into the range of a new type.
|
|
1602
|
+
|
|
1603
|
+
Args:
|
|
1604
|
+
trafo_id (str): Name of the transformer.
|
|
1605
|
+
tap_pos_shift (int): Number of steps added to the current tap position,
|
|
1606
|
+
negative to lower it; `TapChangeStrategy` passes shifts of several
|
|
1607
|
+
steps.
|
|
1608
|
+
|
|
1609
|
+
Returns:
|
|
1610
|
+
bool: True if the position moved by `tap_pos_shift`, False if nothing
|
|
1611
|
+
changed because the new position would be outside the range.
|
|
1612
|
+
|
|
1613
|
+
Raises:
|
|
1614
|
+
ValueError: If no transformer has that name, or several do.
|
|
1615
|
+
"""
|
|
1616
|
+
if not self.network:
|
|
1617
|
+
raise ValueError("No network loaded")
|
|
1618
|
+
|
|
1619
|
+
try:
|
|
1620
|
+
eid = self._element_index("trafo", trafo_id)
|
|
1621
|
+
table = self.network.trafo
|
|
1622
|
+
current, low, high = (
|
|
1623
|
+
table.at[eid, column] for column in ("tap_pos", "tap_min", "tap_max")
|
|
1624
|
+
)
|
|
1625
|
+
if pd.isna(current) or pd.isna(low) or pd.isna(high):
|
|
1626
|
+
self.logger.info(
|
|
1627
|
+
f"Transformer {trafo_id} has no tap range or position: tap "
|
|
1628
|
+
"position not changed"
|
|
1629
|
+
)
|
|
1630
|
+
return False
|
|
1631
|
+
new = current + tap_pos_shift
|
|
1632
|
+
if not low <= new <= high:
|
|
1633
|
+
self.logger.info(
|
|
1634
|
+
f"Tap position of transformer {trafo_id} not changed by "
|
|
1635
|
+
f"{tap_pos_shift}: {new:g} is outside the range {low:g} to {high:g}"
|
|
1636
|
+
)
|
|
1637
|
+
return False
|
|
1638
|
+
table.at[eid, "tap_pos"] = new
|
|
1639
|
+
self.logger.info(
|
|
1640
|
+
f"Changed tap position of transformer {trafo_id} from {current:g} to "
|
|
1641
|
+
f"{new:g}"
|
|
1642
|
+
)
|
|
1643
|
+
return True
|
|
1644
|
+
except Exception as e:
|
|
1645
|
+
self.logger.error(f"Failed to change tap position: {str(e)}")
|
|
1646
|
+
raise
|
|
1647
|
+
|
|
1648
|
+
def get_transformer_tap_position(self, transformer_id: str) -> float | None:
|
|
1649
|
+
"""
|
|
1650
|
+
The tap position of a transformer, None if it has none (NaN).
|
|
1651
|
+
|
|
1652
|
+
Raises:
|
|
1653
|
+
ValueError: If no transformer has that name, or several do.
|
|
1654
|
+
"""
|
|
1655
|
+
if not self.network:
|
|
1656
|
+
raise ValueError("No network loaded")
|
|
1657
|
+
eid = self._element_index("trafo", transformer_id)
|
|
1658
|
+
position = self.network.trafo.at[eid, "tap_pos"]
|
|
1659
|
+
return None if pd.isna(position) else float(position)
|
|
1660
|
+
|
|
1661
|
+
def upgrade_line(self, line_id: str, new_type: str) -> None:
|
|
1662
|
+
"""
|
|
1663
|
+
Upgrade a line with new parameters.
|
|
1664
|
+
|
|
1665
|
+
Args:
|
|
1666
|
+
line_id (str): Name of the line to upgrade.
|
|
1667
|
+
new_type (str): Type of the new line (must exist in standard_types).
|
|
1668
|
+
|
|
1669
|
+
Raises:
|
|
1670
|
+
ValueError: If the type is unknown, or no line has that name, or several do.
|
|
1671
|
+
"""
|
|
1672
|
+
if not self.network:
|
|
1673
|
+
raise ValueError("No network loaded")
|
|
1674
|
+
|
|
1675
|
+
try:
|
|
1676
|
+
# Check if the standard type exists
|
|
1677
|
+
if new_type not in self.network.std_types["line"]:
|
|
1678
|
+
raise ValueError(f"Line type '{new_type}' not found in standard types")
|
|
1679
|
+
|
|
1680
|
+
eid = self._element_index("line", line_id)
|
|
1681
|
+
current_type = self.network.line.at[eid, "std_type"]
|
|
1682
|
+
# Apply the new type
|
|
1683
|
+
pp.change_std_type(self.network, eid, new_type, element="line")
|
|
1684
|
+
self.logger.info(
|
|
1685
|
+
f"Upgraded line {line_id} from {current_type} to type {new_type}"
|
|
1686
|
+
)
|
|
1687
|
+
except Exception as e:
|
|
1688
|
+
self.logger.error(f"Failed to upgrade line: {str(e)}")
|
|
1689
|
+
raise
|
|
1690
|
+
|
|
1691
|
+
def add_parallel_line(self, line_id: str) -> int:
|
|
1692
|
+
"""
|
|
1693
|
+
Add a parallel line.
|
|
1694
|
+
|
|
1695
|
+
Args:
|
|
1696
|
+
line_id (str): Name of the line to add a conductor to.
|
|
1697
|
+
|
|
1698
|
+
Returns:
|
|
1699
|
+
int: Number of parallel conductors of the line after the addition.
|
|
1700
|
+
|
|
1701
|
+
Raises:
|
|
1702
|
+
ValueError: If no line has that name, or several do.
|
|
1703
|
+
"""
|
|
1704
|
+
if not self.network:
|
|
1705
|
+
raise ValueError("No network loaded")
|
|
1706
|
+
|
|
1707
|
+
try:
|
|
1708
|
+
eid = self._element_index("line", line_id)
|
|
1709
|
+
self.network.line.loc[eid, "parallel"] += 1
|
|
1710
|
+
self.logger.info(f"Added parallel line to {line_id}")
|
|
1711
|
+
return self.network.line.at[eid, "parallel"]
|
|
1712
|
+
except Exception as e:
|
|
1713
|
+
self.logger.error(f"Failed to add parallel line: {str(e)}")
|
|
1714
|
+
raise
|
|
1715
|
+
|
|
1716
|
+
def set_line_parallel(self, line_id: str, parallel: int) -> int:
|
|
1717
|
+
"""
|
|
1718
|
+
Set the number of parallel conductors of the line named `line_id`, fewer
|
|
1719
|
+
than it has or more.
|
|
1720
|
+
|
|
1721
|
+
Args:
|
|
1722
|
+
line_id (str): Name of the line.
|
|
1723
|
+
parallel (int): Its number of conductors, a whole number of 1 or more:
|
|
1724
|
+
an integer, or a float without a fractional part, of any numeric
|
|
1725
|
+
type, but not a boolean or a string.
|
|
1726
|
+
|
|
1727
|
+
Returns:
|
|
1728
|
+
int: The number of conductors of the line.
|
|
1729
|
+
|
|
1730
|
+
Raises:
|
|
1731
|
+
ValueError: If no network is loaded, if no line has that name, or if
|
|
1732
|
+
`parallel` is not a whole number of 1 or more.
|
|
1733
|
+
"""
|
|
1734
|
+
if not self.network:
|
|
1735
|
+
raise ValueError("No network loaded")
|
|
1736
|
+
# A whole number of any numeric type, not a boolean, a string or None
|
|
1737
|
+
if isinstance(parallel, numbers.Integral) and not isinstance(parallel, bool):
|
|
1738
|
+
whole = True
|
|
1739
|
+
elif isinstance(parallel, numbers.Real) and not isinstance(parallel, bool):
|
|
1740
|
+
whole = float(parallel).is_integer()
|
|
1741
|
+
else:
|
|
1742
|
+
whole = False
|
|
1743
|
+
if not whole or parallel < 1:
|
|
1744
|
+
raise ValueError(
|
|
1745
|
+
f"A line has a whole number of parallel conductors, 1 or more, not "
|
|
1746
|
+
f"{parallel!r}"
|
|
1747
|
+
)
|
|
1748
|
+
mask = self.network.line.name == line_id
|
|
1749
|
+
if not mask.any():
|
|
1750
|
+
raise ValueError(f"Line with name '{line_id}' not found in the network")
|
|
1751
|
+
self.network.line.loc[mask, "parallel"] = int(parallel)
|
|
1752
|
+
self.logger.info(f"Set line {line_id} to {int(parallel)} parallel conductors")
|
|
1753
|
+
return int(parallel)
|
|
1754
|
+
|
|
1755
|
+
def save_line(self, line_id: str) -> pd.DataFrame:
|
|
1756
|
+
"""
|
|
1757
|
+
Save the row of the line table of the line named `line_id`, for
|
|
1758
|
+
`restore_line`.
|
|
1759
|
+
|
|
1760
|
+
Returns:
|
|
1761
|
+
pd.DataFrame: A copy of the row, with its index.
|
|
1762
|
+
|
|
1763
|
+
Raises:
|
|
1764
|
+
ValueError: If no network is loaded or no line has that name.
|
|
1765
|
+
"""
|
|
1766
|
+
if not self.network:
|
|
1767
|
+
raise ValueError("No network loaded")
|
|
1768
|
+
mask = self.network.line.name == line_id
|
|
1769
|
+
if not mask.any():
|
|
1770
|
+
raise ValueError(f"Line with name '{line_id}' not found in the network")
|
|
1771
|
+
return self.network.line.loc[mask].copy()
|
|
1772
|
+
|
|
1773
|
+
def restore_line(self, line_id: str, saved: pd.DataFrame) -> None:
|
|
1774
|
+
"""
|
|
1775
|
+
Give the line named `line_id` back the row `save_line` saved for it, every
|
|
1776
|
+
column as it was, its type and parameters as well as its conductors.
|
|
1777
|
+
|
|
1778
|
+
Raises:
|
|
1779
|
+
ValueError: If no network is loaded, or if `saved` is not the row of the
|
|
1780
|
+
line of that name.
|
|
1781
|
+
"""
|
|
1782
|
+
if not self.network:
|
|
1783
|
+
raise ValueError("No network loaded")
|
|
1784
|
+
line = self.network.line
|
|
1785
|
+
mask = line.name == line_id
|
|
1786
|
+
if (
|
|
1787
|
+
not isinstance(saved, pd.DataFrame)
|
|
1788
|
+
or not mask.any()
|
|
1789
|
+
or list(line.index[mask]) != list(saved.index)
|
|
1790
|
+
or (saved["name"] != line_id).any()
|
|
1791
|
+
):
|
|
1792
|
+
raise ValueError(f"What is given is not a saved row of line '{line_id}'")
|
|
1793
|
+
for column in saved.columns:
|
|
1794
|
+
line.loc[saved.index, column] = saved[column]
|
|
1795
|
+
self.logger.info(f"Restored line {line_id}")
|
|
1796
|
+
|
|
1797
|
+
def save_transformer(self, transformer_id: str) -> pd.DataFrame:
|
|
1798
|
+
"""
|
|
1799
|
+
Save the row of the transformer table of the transformer named
|
|
1800
|
+
`transformer_id`, for `restore_transformer`.
|
|
1801
|
+
|
|
1802
|
+
Returns:
|
|
1803
|
+
pd.DataFrame: A copy of the row, with its index.
|
|
1804
|
+
|
|
1805
|
+
Raises:
|
|
1806
|
+
ValueError: If no network is loaded or no transformer has that name.
|
|
1807
|
+
"""
|
|
1808
|
+
if not self.network:
|
|
1809
|
+
raise ValueError("No network loaded")
|
|
1810
|
+
mask = self.network.trafo.name == transformer_id
|
|
1811
|
+
if not mask.any():
|
|
1812
|
+
raise ValueError(
|
|
1813
|
+
f"Transformer with name '{transformer_id}' not found in the network"
|
|
1814
|
+
)
|
|
1815
|
+
return self.network.trafo.loc[mask].copy()
|
|
1816
|
+
|
|
1817
|
+
def restore_transformer(self, transformer_id: str, saved: pd.DataFrame) -> None:
|
|
1818
|
+
"""
|
|
1819
|
+
Give the transformer named `transformer_id` back the row `save_transformer`
|
|
1820
|
+
saved for it, every column as it was, its type and parameters as well as its
|
|
1821
|
+
units.
|
|
1822
|
+
|
|
1823
|
+
Raises:
|
|
1824
|
+
ValueError: If no network is loaded, or if `saved` is not the row of the
|
|
1825
|
+
transformer of that name.
|
|
1826
|
+
"""
|
|
1827
|
+
if not self.network:
|
|
1828
|
+
raise ValueError("No network loaded")
|
|
1829
|
+
trafo = self.network.trafo
|
|
1830
|
+
mask = trafo.name == transformer_id
|
|
1831
|
+
if (
|
|
1832
|
+
not isinstance(saved, pd.DataFrame)
|
|
1833
|
+
or not mask.any()
|
|
1834
|
+
or list(trafo.index[mask]) != list(saved.index)
|
|
1835
|
+
or (saved["name"] != transformer_id).any()
|
|
1836
|
+
):
|
|
1837
|
+
raise ValueError(
|
|
1838
|
+
f"What is given is not a saved row of transformer '{transformer_id}'"
|
|
1839
|
+
)
|
|
1840
|
+
for column in saved.columns:
|
|
1841
|
+
trafo.loc[saved.index, column] = saved[column]
|
|
1842
|
+
self.logger.info(f"Restored transformer {transformer_id}")
|
|
1843
|
+
|
|
1844
|
+
# What pandapower keeps of a run besides the result tables: the internal case and
|
|
1845
|
+
# its lookups, which each run replaces by new objects, and the convergence flag
|
|
1846
|
+
_SOLUTION_KEYS = (
|
|
1847
|
+
"_ppc",
|
|
1848
|
+
"_pd2ppc_lookups",
|
|
1849
|
+
"_options",
|
|
1850
|
+
"_is_elements",
|
|
1851
|
+
"_is_elements_final",
|
|
1852
|
+
"_isolated_buses",
|
|
1853
|
+
"_isolated_buses_dc",
|
|
1854
|
+
"_impedance_bb_switches",
|
|
1855
|
+
"_gen_order",
|
|
1856
|
+
"converged",
|
|
1857
|
+
)
|
|
1858
|
+
|
|
1859
|
+
def save_solution(self) -> dict[str, Any]:
|
|
1860
|
+
"""
|
|
1861
|
+
Save the solution of the latest power flow, for `restore_solution`: a copy of
|
|
1862
|
+
every result table (`res_*`), and what the engine and pandapower keep of the
|
|
1863
|
+
run, which the next run replaces rather than changes: the internal case
|
|
1864
|
+
(`_ppc`) and its lookups, from which the sensitivities are computed, the
|
|
1865
|
+
convergence flags, `latest_results`, and the Jacobian and its factors.
|
|
1866
|
+
|
|
1867
|
+
A power flow whose controllers act (`run_control` in the settings, with a
|
|
1868
|
+
controller in service) changes the network as well as its results: a tap
|
|
1869
|
+
moved by a controller in the power flow after a step would stay moved when
|
|
1870
|
+
the step is undone, and the solution put back would no longer be that of the
|
|
1871
|
+
network. Such a solution is not saved: the strategies then take their steps
|
|
1872
|
+
unchecked, as on an engine that cannot save a solution.
|
|
1873
|
+
|
|
1874
|
+
Returns:
|
|
1875
|
+
dict: The saved solution.
|
|
1876
|
+
|
|
1877
|
+
Raises:
|
|
1878
|
+
ValueError: If no network is loaded.
|
|
1879
|
+
NotImplementedError: If the controllers act in the power flow.
|
|
1880
|
+
"""
|
|
1881
|
+
if not self.network:
|
|
1882
|
+
raise ValueError("No network loaded")
|
|
1883
|
+
if self._controllers_act():
|
|
1884
|
+
raise NotImplementedError(
|
|
1885
|
+
"The solution of a power flow whose controllers act is not saved: "
|
|
1886
|
+
"undoing a step would not undo what the controllers changed"
|
|
1887
|
+
)
|
|
1888
|
+
net = self.network
|
|
1889
|
+
return {
|
|
1890
|
+
# None for a table that is empty, as most are
|
|
1891
|
+
"tables": {
|
|
1892
|
+
key: net[key].copy() if len(net[key]) else None
|
|
1893
|
+
for key in net.keys()
|
|
1894
|
+
if key.startswith("res_") and isinstance(net[key], pd.DataFrame)
|
|
1895
|
+
},
|
|
1896
|
+
"kept": {key: net[key] for key in self._SOLUTION_KEYS if key in net},
|
|
1897
|
+
"latest_results": copy.copy(self.latest_results),
|
|
1898
|
+
"caches": (self._jacobian_cache, self._jacobian_lu_cache),
|
|
1899
|
+
}
|
|
1900
|
+
|
|
1901
|
+
def restore_solution(self, saved: dict[str, Any]) -> None:
|
|
1902
|
+
"""
|
|
1903
|
+
Put back the solution `save_solution` saved: copies of its result tables, so
|
|
1904
|
+
that it can be put back again, and what the run left besides them.
|
|
1905
|
+
|
|
1906
|
+
Raises:
|
|
1907
|
+
ValueError: If no network is loaded.
|
|
1908
|
+
"""
|
|
1909
|
+
if not self.network:
|
|
1910
|
+
raise ValueError("No network loaded")
|
|
1911
|
+
net = self.network
|
|
1912
|
+
for key, table in saved["tables"].items():
|
|
1913
|
+
if table is not None:
|
|
1914
|
+
net[key] = table.copy()
|
|
1915
|
+
elif len(net[key]):
|
|
1916
|
+
net[key] = net[key].iloc[0:0].copy()
|
|
1917
|
+
for key, value in saved["kept"].items():
|
|
1918
|
+
net[key] = value
|
|
1919
|
+
self.latest_results = copy.copy(saved["latest_results"])
|
|
1920
|
+
self._jacobian_cache, self._jacobian_lu_cache = saved["caches"]
|
|
1921
|
+
|
|
1922
|
+
# The parameters of a transformer that its replacement keeps: the vector group seen
|
|
1923
|
+
# by the network, as its phase shift and as its name
|
|
1924
|
+
_KEPT_BY_A_TYPE_CHANGE = ("shift_degree", "vector_group")
|
|
1925
|
+
|
|
1926
|
+
def upgrade_transformer(self, trafo_id: str, new_type: str) -> None:
|
|
1927
|
+
"""
|
|
1928
|
+
Upgrade a transformer with new parameters.
|
|
1929
|
+
|
|
1930
|
+
The units take every parameter of the new type but the vector group of the
|
|
1931
|
+
units in place: their phase shift (``shift_degree``) and, where the table has
|
|
1932
|
+
the column, its name (``vector_group``), whatever the type is catalogued with.
|
|
1933
|
+
A replacement unit is one of the new rating, connected as the one it replaces:
|
|
1934
|
+
the network beyond it is not turned by the difference of shifts, 180 degrees
|
|
1935
|
+
from a Dyn11 unit to a Dyn5 type (#56). Three-winding transformers are not
|
|
1936
|
+
upgraded.
|
|
1937
|
+
|
|
1938
|
+
The unit keeps its tap position, which is brought into the tap range of the new
|
|
1939
|
+
type (``tap_min`` to ``tap_max``) when it is outside, with a warning that names
|
|
1940
|
+
the transformer and both positions. Nothing changes, and nothing is logged, for
|
|
1941
|
+
a position within the range, or when the table has no range or position (NaN).
|
|
1942
|
+
A type without tap columns leaves the unit the range it had, and its position:
|
|
1943
|
+
pandapower's `change_std_type` keeps the tap columns of the row then.
|
|
1944
|
+
|
|
1945
|
+
Args:
|
|
1946
|
+
trafo_id (str): Name of the transformer to upgrade.
|
|
1947
|
+
new_type (str): Type of the new transformer (must exist in standard_types).
|
|
1948
|
+
|
|
1949
|
+
Raises:
|
|
1950
|
+
ValueError: If the type is unknown, or no transformer has that name, or
|
|
1951
|
+
several do.
|
|
1952
|
+
"""
|
|
1953
|
+
if not self.network:
|
|
1954
|
+
raise ValueError("No network loaded")
|
|
1955
|
+
|
|
1956
|
+
try:
|
|
1957
|
+
# Check if the standard type exists
|
|
1958
|
+
if new_type not in self.network.std_types["trafo"]:
|
|
1959
|
+
raise ValueError(
|
|
1960
|
+
f"Transformer type '{new_type}' not found in standard types"
|
|
1961
|
+
)
|
|
1962
|
+
|
|
1963
|
+
table = self.network.trafo
|
|
1964
|
+
eid = self._element_index("trafo", trafo_id)
|
|
1965
|
+
kept = {
|
|
1966
|
+
column: table.at[eid, column]
|
|
1967
|
+
for column in self._KEPT_BY_A_TYPE_CHANGE
|
|
1968
|
+
if column in table
|
|
1969
|
+
}
|
|
1970
|
+
# Apply the new type
|
|
1971
|
+
pp.change_std_type(self.network, eid, new_type, element="trafo")
|
|
1972
|
+
for column, value in kept.items():
|
|
1973
|
+
table.at[eid, column] = value
|
|
1974
|
+
self.logger.info(f"Upgraded transformer {trafo_id} to type {new_type}")
|
|
1975
|
+
self._clamp_tap_position(trafo_id, eid, new_type)
|
|
1976
|
+
except Exception as e:
|
|
1977
|
+
self.logger.error(f"Failed to upgrade transformer: {str(e)}")
|
|
1978
|
+
raise
|
|
1979
|
+
|
|
1980
|
+
def _clamp_tap_position(self, trafo_id: str, eid: int, new_type: str) -> None:
|
|
1981
|
+
"""
|
|
1982
|
+
Bring the tap position of the transformer at `eid` into the tap range its table
|
|
1983
|
+
row has, which a type change has just replaced by that of the new type: the unit
|
|
1984
|
+
keeps its position, which another range can leave outside it. Logs a warning
|
|
1985
|
+
when it moves it. A row without a range or a position (NaN) is left alone. A
|
|
1986
|
+
type without tap columns does not give the row one: pandapower's
|
|
1987
|
+
`change_std_type` then keeps the ``tap_min``, ``tap_max``, ``tap_neutral`` and
|
|
1988
|
+
``tap_step_*`` the row had, so that the unit keeps its range and its position.
|
|
1989
|
+
"""
|
|
1990
|
+
table = self.network.trafo
|
|
1991
|
+
if not {"tap_pos", "tap_min", "tap_max"} <= set(table.columns):
|
|
1992
|
+
return
|
|
1993
|
+
position, low, high = (
|
|
1994
|
+
table.at[eid, c] for c in ("tap_pos", "tap_min", "tap_max")
|
|
1995
|
+
)
|
|
1996
|
+
if pd.isna(position) or pd.isna(low) or pd.isna(high) or low > high:
|
|
1997
|
+
return
|
|
1998
|
+
clamped = min(max(position, low), high)
|
|
1999
|
+
if clamped == position:
|
|
2000
|
+
return
|
|
2001
|
+
table.at[eid, "tap_pos"] = clamped
|
|
2002
|
+
self.logger.warning(
|
|
2003
|
+
f"Tap position of transformer {trafo_id} moved from {position:g} to "
|
|
2004
|
+
f"{clamped:g}, into the range {low:g} to {high:g} of type {new_type}"
|
|
2005
|
+
)
|
|
2006
|
+
|
|
2007
|
+
def add_parallel_transformer(self, trafo_id: str) -> int:
|
|
2008
|
+
"""
|
|
2009
|
+
Add a parallel transformer.
|
|
2010
|
+
|
|
2011
|
+
Args:
|
|
2012
|
+
trafo_id (str): Name of the transformer to add a unit to.
|
|
2013
|
+
|
|
2014
|
+
Returns:
|
|
2015
|
+
int: Number of parallel units of the transformer after the addition.
|
|
2016
|
+
|
|
2017
|
+
Raises:
|
|
2018
|
+
ValueError: If no transformer has that name, or several do.
|
|
2019
|
+
"""
|
|
2020
|
+
if not self.network:
|
|
2021
|
+
raise ValueError("No network loaded")
|
|
2022
|
+
|
|
2023
|
+
try:
|
|
2024
|
+
eid = self._element_index("trafo", trafo_id)
|
|
2025
|
+
self.network.trafo.loc[eid, "parallel"] += 1
|
|
2026
|
+
self.logger.info(f"Added parallel transformer to {trafo_id}")
|
|
2027
|
+
return self.network.trafo.at[eid, "parallel"]
|
|
2028
|
+
except Exception as e:
|
|
2029
|
+
self.logger.error(f"Failed to add parallel transformer: {str(e)}")
|
|
2030
|
+
raise
|
|
2031
|
+
|
|
2032
|
+
def get_losses(self) -> dict[str, float]:
|
|
2033
|
+
"""
|
|
2034
|
+
Calculate network losses.
|
|
2035
|
+
|
|
2036
|
+
Returns:
|
|
2037
|
+
Dict[str, float]: Dictionary with active and reactive power losses.
|
|
2038
|
+
"""
|
|
2039
|
+
if (
|
|
2040
|
+
not self.network
|
|
2041
|
+
or not self.latest_results
|
|
2042
|
+
or not self.latest_results.get("converged", False)
|
|
2043
|
+
):
|
|
2044
|
+
raise ValueError("Need a converged power flow solution to calculate losses")
|
|
2045
|
+
|
|
2046
|
+
# Calculate total losses
|
|
2047
|
+
p_losses = 0.0
|
|
2048
|
+
q_losses = 0.0
|
|
2049
|
+
|
|
2050
|
+
# Line losses
|
|
2051
|
+
if "pl_mw" in self.network.res_line:
|
|
2052
|
+
p_losses += self.network.res_line.pl_mw.sum()
|
|
2053
|
+
if "ql_mvar" in self.network.res_line:
|
|
2054
|
+
q_losses += self.network.res_line.ql_mvar.sum()
|
|
2055
|
+
|
|
2056
|
+
# Transformer losses
|
|
2057
|
+
if "pl_mw" in self.network.res_trafo:
|
|
2058
|
+
p_losses += self.network.res_trafo.pl_mw.sum()
|
|
2059
|
+
if "ql_mvar" in self.network.res_trafo:
|
|
2060
|
+
q_losses += self.network.res_trafo.ql_mvar.sum()
|
|
2061
|
+
|
|
2062
|
+
return {"p_loss_mw": p_losses, "q_loss_mvar": q_losses}
|
|
2063
|
+
|
|
2064
|
+
def get_network_metrics(self) -> dict[str, Any]:
|
|
2065
|
+
"""
|
|
2066
|
+
Get various network metrics.
|
|
2067
|
+
|
|
2068
|
+
Returns:
|
|
2069
|
+
Dict[str, Any]: Dictionary with network metrics.
|
|
2070
|
+
"""
|
|
2071
|
+
if not self.network:
|
|
2072
|
+
raise ValueError("No network loaded")
|
|
2073
|
+
|
|
2074
|
+
metrics = {
|
|
2075
|
+
"network_size": {
|
|
2076
|
+
"buses": len(self.network.bus),
|
|
2077
|
+
"lines": len(self.network.line),
|
|
2078
|
+
"transformers": len(self.network.trafo),
|
|
2079
|
+
"loads": len(self.network.load) if hasattr(self.network, "load") else 0,
|
|
2080
|
+
"generators": len(self.network.gen)
|
|
2081
|
+
if hasattr(self.network, "gen")
|
|
2082
|
+
else 0,
|
|
2083
|
+
"sgens": len(self.network.sgen) if hasattr(self.network, "sgen") else 0,
|
|
2084
|
+
}
|
|
2085
|
+
}
|
|
2086
|
+
|
|
2087
|
+
# Add voltage statistics if power flow results are available
|
|
2088
|
+
if self.latest_results and self.latest_results.get("converged", False):
|
|
2089
|
+
metrics["voltage"] = self.network.res_bus.vm_pu.describe().to_dict()
|
|
2090
|
+
|
|
2091
|
+
# Add loading statistics
|
|
2092
|
+
if "loading_percent" in self.network.res_line:
|
|
2093
|
+
metrics["line_loading"] = (
|
|
2094
|
+
self.network.res_line.loading_percent.describe().to_dict()
|
|
2095
|
+
)
|
|
2096
|
+
|
|
2097
|
+
if "loading_percent" in self.network.res_trafo:
|
|
2098
|
+
metrics["trafo_loading"] = (
|
|
2099
|
+
self.network.res_trafo.loading_percent.describe().to_dict()
|
|
2100
|
+
)
|
|
2101
|
+
|
|
2102
|
+
# Add loss metrics
|
|
2103
|
+
losses = self.get_losses()
|
|
2104
|
+
metrics["losses"] = losses
|
|
2105
|
+
|
|
2106
|
+
return metrics
|
|
2107
|
+
|
|
2108
|
+
def create_topology_graph(self) -> Any:
|
|
2109
|
+
"""
|
|
2110
|
+
Create a NetworkX graph representing the network topology.
|
|
2111
|
+
|
|
2112
|
+
Returns:
|
|
2113
|
+
networkx.Graph: NetworkX graph object.
|
|
2114
|
+
"""
|
|
2115
|
+
try:
|
|
2116
|
+
import networkx as nx
|
|
2117
|
+
except ImportError:
|
|
2118
|
+
self.logger.error(
|
|
2119
|
+
"NetworkX is required for topology graph creation but not installed"
|
|
2120
|
+
)
|
|
2121
|
+
raise ImportError("NetworkX is required for topology graph creation")
|
|
2122
|
+
|
|
2123
|
+
if not self.network:
|
|
2124
|
+
raise ValueError("No network loaded")
|
|
2125
|
+
|
|
2126
|
+
# Create undirected graph
|
|
2127
|
+
G = nx.Graph()
|
|
2128
|
+
|
|
2129
|
+
# Prefer explicit pandapower geodata tables when available.
|
|
2130
|
+
bus_geodata = None
|
|
2131
|
+
if hasattr(self.network, "bus_geodata"):
|
|
2132
|
+
if (
|
|
2133
|
+
self.network.bus_geodata is not None
|
|
2134
|
+
and not self.network.bus_geodata.empty
|
|
2135
|
+
):
|
|
2136
|
+
bus_geodata = self.network.bus_geodata
|
|
2137
|
+
|
|
2138
|
+
# Fall back to the "geo" column in the bus table when bus_geodata is missing.
|
|
2139
|
+
use_bus_geo_column = False
|
|
2140
|
+
if bus_geodata is None and "geo" in self.network.bus.columns:
|
|
2141
|
+
if self.network.bus["geo"].notna().any():
|
|
2142
|
+
use_bus_geo_column = True
|
|
2143
|
+
|
|
2144
|
+
# Add buses as nodes
|
|
2145
|
+
for i, bus in self.network.bus.iterrows():
|
|
2146
|
+
node_attrs = {
|
|
2147
|
+
"type": "bus",
|
|
2148
|
+
"voltage": bus.vn_kv,
|
|
2149
|
+
"name": bus.get("name"),
|
|
2150
|
+
}
|
|
2151
|
+
# Use coordinates from bus_geodata if present.
|
|
2152
|
+
if bus_geodata is not None and i in bus_geodata.index:
|
|
2153
|
+
x = float(bus_geodata.at[i, "x"])
|
|
2154
|
+
y = float(bus_geodata.at[i, "y"])
|
|
2155
|
+
node_attrs["x"] = x
|
|
2156
|
+
node_attrs["y"] = y
|
|
2157
|
+
node_attrs["pos"] = (x, y)
|
|
2158
|
+
elif use_bus_geo_column:
|
|
2159
|
+
# Parse GeoJSON points from the "geo" column.
|
|
2160
|
+
geo = bus.get("geo")
|
|
2161
|
+
if isinstance(geo, str):
|
|
2162
|
+
try:
|
|
2163
|
+
import json
|
|
2164
|
+
|
|
2165
|
+
geo = json.loads(geo)
|
|
2166
|
+
except Exception:
|
|
2167
|
+
geo = None
|
|
2168
|
+
if isinstance(geo, dict) and geo.get("type") == "Point":
|
|
2169
|
+
coords = geo.get("coordinates", [])
|
|
2170
|
+
if isinstance(coords, list | tuple) and len(coords) >= 2:
|
|
2171
|
+
x = float(coords[0])
|
|
2172
|
+
y = float(coords[1])
|
|
2173
|
+
node_attrs["x"] = x
|
|
2174
|
+
node_attrs["y"] = y
|
|
2175
|
+
node_attrs["pos"] = (x, y)
|
|
2176
|
+
G.add_node(i, **node_attrs)
|
|
2177
|
+
|
|
2178
|
+
# Pull line geodata if present to draw polylines.
|
|
2179
|
+
line_geodata = None
|
|
2180
|
+
if hasattr(self.network, "line_geodata"):
|
|
2181
|
+
if (
|
|
2182
|
+
self.network.line_geodata is not None
|
|
2183
|
+
and not self.network.line_geodata.empty
|
|
2184
|
+
):
|
|
2185
|
+
line_geodata = self.network.line_geodata
|
|
2186
|
+
# Fall back to the "geo" column in the line table when line_geodata is missing.
|
|
2187
|
+
use_line_geo_column = False
|
|
2188
|
+
if line_geodata is None and "geo" in self.network.line.columns:
|
|
2189
|
+
if self.network.line["geo"].notna().any():
|
|
2190
|
+
use_line_geo_column = True
|
|
2191
|
+
|
|
2192
|
+
# Add lines as edges
|
|
2193
|
+
for i, line in self.network.line.iterrows():
|
|
2194
|
+
from_bus = line.from_bus
|
|
2195
|
+
to_bus = line.to_bus
|
|
2196
|
+
edge_attrs = {
|
|
2197
|
+
"type": "line",
|
|
2198
|
+
"id": i,
|
|
2199
|
+
"name": line.get("name"),
|
|
2200
|
+
}
|
|
2201
|
+
# Attach explicit line coordinates if available.
|
|
2202
|
+
if line_geodata is not None and i in line_geodata.index:
|
|
2203
|
+
coords = line_geodata.at[i, "coords"]
|
|
2204
|
+
if coords is not None:
|
|
2205
|
+
edge_attrs["coords"] = coords
|
|
2206
|
+
elif use_line_geo_column:
|
|
2207
|
+
# Parse GeoJSON lines from the "geo" column.
|
|
2208
|
+
geo = line.get("geo")
|
|
2209
|
+
if isinstance(geo, str):
|
|
2210
|
+
try:
|
|
2211
|
+
import json
|
|
2212
|
+
|
|
2213
|
+
geo = json.loads(geo)
|
|
2214
|
+
except Exception:
|
|
2215
|
+
geo = None
|
|
2216
|
+
if isinstance(geo, dict) and geo.get("type") == "LineString":
|
|
2217
|
+
coords = geo.get("coordinates", [])
|
|
2218
|
+
if coords is not None:
|
|
2219
|
+
edge_attrs["coords"] = coords
|
|
2220
|
+
G.add_edge(from_bus, to_bus, **edge_attrs)
|
|
2221
|
+
|
|
2222
|
+
# Add transformers as edges
|
|
2223
|
+
for i, trafo in self.network.trafo.iterrows():
|
|
2224
|
+
hv_bus = trafo.hv_bus
|
|
2225
|
+
lv_bus = trafo.lv_bus
|
|
2226
|
+
edge_attrs = {
|
|
2227
|
+
"type": "transformer",
|
|
2228
|
+
"id": i,
|
|
2229
|
+
"name": trafo.get("name"),
|
|
2230
|
+
}
|
|
2231
|
+
# Compute a midpoint for transformer markers when bus positions are known.
|
|
2232
|
+
if bus_geodata is not None:
|
|
2233
|
+
if hv_bus in bus_geodata.index and lv_bus in bus_geodata.index:
|
|
2234
|
+
x1 = float(bus_geodata.at[hv_bus, "x"])
|
|
2235
|
+
y1 = float(bus_geodata.at[hv_bus, "y"])
|
|
2236
|
+
x2 = float(bus_geodata.at[lv_bus, "x"])
|
|
2237
|
+
y2 = float(bus_geodata.at[lv_bus, "y"])
|
|
2238
|
+
edge_attrs["midpoint"] = ((x1 + x2) / 2.0, (y1 + y2) / 2.0)
|
|
2239
|
+
elif use_bus_geo_column:
|
|
2240
|
+
hv_geo = self.network.bus.at[hv_bus, "geo"]
|
|
2241
|
+
lv_geo = self.network.bus.at[lv_bus, "geo"]
|
|
2242
|
+
for name, value in (("hv", hv_geo), ("lv", lv_geo)):
|
|
2243
|
+
if isinstance(value, str):
|
|
2244
|
+
try:
|
|
2245
|
+
import json
|
|
2246
|
+
|
|
2247
|
+
value = json.loads(value)
|
|
2248
|
+
except Exception:
|
|
2249
|
+
value = None
|
|
2250
|
+
if name == "hv":
|
|
2251
|
+
hv_geo = value
|
|
2252
|
+
else:
|
|
2253
|
+
lv_geo = value
|
|
2254
|
+
# Parse GeoJSON points for transformer midpoint computation.
|
|
2255
|
+
if (
|
|
2256
|
+
isinstance(hv_geo, dict)
|
|
2257
|
+
and hv_geo.get("type") == "Point"
|
|
2258
|
+
and isinstance(lv_geo, dict)
|
|
2259
|
+
and lv_geo.get("type") == "Point"
|
|
2260
|
+
):
|
|
2261
|
+
hv_coords = hv_geo.get("coordinates", [])
|
|
2262
|
+
lv_coords = lv_geo.get("coordinates", [])
|
|
2263
|
+
if (
|
|
2264
|
+
isinstance(hv_coords, list | tuple)
|
|
2265
|
+
and len(hv_coords) >= 2
|
|
2266
|
+
and isinstance(lv_coords, list | tuple)
|
|
2267
|
+
and len(lv_coords) >= 2
|
|
2268
|
+
):
|
|
2269
|
+
x1 = float(hv_coords[0])
|
|
2270
|
+
y1 = float(hv_coords[1])
|
|
2271
|
+
x2 = float(lv_coords[0])
|
|
2272
|
+
y2 = float(lv_coords[1])
|
|
2273
|
+
edge_attrs["midpoint"] = ((x1 + x2) / 2.0, (y1 + y2) / 2.0)
|
|
2274
|
+
G.add_edge(hv_bus, lv_bus, **edge_attrs)
|
|
2275
|
+
|
|
2276
|
+
return G
|
|
2277
|
+
|
|
2278
|
+
def get_line_imax(self, line_type):
|
|
2279
|
+
"""
|
|
2280
|
+
Fetches and returns the maximum intensity for a given line type.
|
|
2281
|
+
|
|
2282
|
+
Args:
|
|
2283
|
+
line_type (str): Specifies the type of line for which the maximum value is to be retrieved.
|
|
2284
|
+
|
|
2285
|
+
Returns:
|
|
2286
|
+
float: The maximum intensity associated with the specified line type.
|
|
2287
|
+
"""
|
|
2288
|
+
|
|
2289
|
+
try:
|
|
2290
|
+
line_std_type = self.network.std_types["line"][line_type]
|
|
2291
|
+
except KeyError:
|
|
2292
|
+
self.logger.error(f"Line type '{line_type}' not found in standard types")
|
|
2293
|
+
raise ValueError(f"Line type '{line_type}' not found in standard types")
|
|
2294
|
+
|
|
2295
|
+
return line_std_type["max_i_ka"] * 1000.0 # pandapower stores data in kA
|
|
2296
|
+
|
|
2297
|
+
def get_line_r_ohm_per_km(self, line_type: str) -> float:
|
|
2298
|
+
"""
|
|
2299
|
+
Get the resistance per unit length for a given line type.
|
|
2300
|
+
|
|
2301
|
+
Args:
|
|
2302
|
+
line_type (str): The type of the line.
|
|
2303
|
+
|
|
2304
|
+
Returns:
|
|
2305
|
+
float: The resistance per unit length (Ohm/km).
|
|
2306
|
+
"""
|
|
2307
|
+
if self.network is None:
|
|
2308
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
2309
|
+
|
|
2310
|
+
try:
|
|
2311
|
+
line_std_type = self.network.std_types["line"][line_type]
|
|
2312
|
+
return line_std_type["r_ohm_per_km"]
|
|
2313
|
+
except KeyError:
|
|
2314
|
+
self.logger.error(f"Line type '{line_type}' not found in standard types")
|
|
2315
|
+
raise ValueError(f"Line type '{line_type}' not found in standard types")
|
|
2316
|
+
|
|
2317
|
+
def get_line_type(self, line_id: str) -> str:
|
|
2318
|
+
"""
|
|
2319
|
+
Returns the type of a line based on the provided line ID.
|
|
2320
|
+
|
|
2321
|
+
Args:
|
|
2322
|
+
line_id (str): The unique identifier (name) of the line.
|
|
2323
|
+
|
|
2324
|
+
Returns:
|
|
2325
|
+
str: The standard type of the line.
|
|
2326
|
+
|
|
2327
|
+
Raises:
|
|
2328
|
+
ValueError: If the network is not initialized or if the line is not found.
|
|
2329
|
+
"""
|
|
2330
|
+
if self.network is None:
|
|
2331
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
2332
|
+
|
|
2333
|
+
try:
|
|
2334
|
+
# Find the line with the given name and return the standard type of the line
|
|
2335
|
+
return self.network.line.loc[
|
|
2336
|
+
self.network.line.name == line_id, "std_type"
|
|
2337
|
+
].iloc[0]
|
|
2338
|
+
except (IndexError, KeyError):
|
|
2339
|
+
self.logger.error(f"Line with name '{line_id}' not found in the network")
|
|
2340
|
+
raise ValueError(f"Line with name '{line_id}' not found in the network")
|
|
2341
|
+
|
|
2342
|
+
def get_line_length(self, line_id: int | str) -> float:
|
|
2343
|
+
"""
|
|
2344
|
+
Get the length of a line by its ID.
|
|
2345
|
+
|
|
2346
|
+
Args:
|
|
2347
|
+
line_id (Union[int, str]): The ID of the line.
|
|
2348
|
+
|
|
2349
|
+
Returns:
|
|
2350
|
+
float: The length of the line in kilometers.
|
|
2351
|
+
|
|
2352
|
+
Raises:
|
|
2353
|
+
ValueError: If the network is not initialized or if the line is not found.
|
|
2354
|
+
"""
|
|
2355
|
+
if self.network is None:
|
|
2356
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
2357
|
+
|
|
2358
|
+
try:
|
|
2359
|
+
# Find the line with the given name and return its length
|
|
2360
|
+
return self.network.line.loc[
|
|
2361
|
+
self.network.line.name == line_id, "length_km"
|
|
2362
|
+
].iloc[0]
|
|
2363
|
+
except (IndexError, KeyError):
|
|
2364
|
+
self.logger.error(f"Line with name '{line_id}' not found in the network")
|
|
2365
|
+
raise ValueError(f"Line with name '{line_id}' not found in the network")
|
|
2366
|
+
|
|
2367
|
+
def get_line_parallel(self, line_id: int | str) -> int:
|
|
2368
|
+
"""
|
|
2369
|
+
Get the number of parallel conductors of a line (1 for a single line).
|
|
2370
|
+
"""
|
|
2371
|
+
try:
|
|
2372
|
+
return int(
|
|
2373
|
+
self.network.line.loc[
|
|
2374
|
+
self.network.line.name == line_id, "parallel"
|
|
2375
|
+
].iloc[0]
|
|
2376
|
+
)
|
|
2377
|
+
except (IndexError, KeyError):
|
|
2378
|
+
return 1
|
|
2379
|
+
|
|
2380
|
+
def get_line_rating(self, line_id: int | str) -> float | None:
|
|
2381
|
+
"""
|
|
2382
|
+
Get the rating (A) of one conductor of a line, as the line table holds it
|
|
2383
|
+
(`max_i_ka`), whether or not it is that of its type. The loading the engine
|
|
2384
|
+
reports is relative to it, times the derating factor `df` and the parallel
|
|
2385
|
+
conductors.
|
|
2386
|
+
|
|
2387
|
+
Returns:
|
|
2388
|
+
Optional[float]: The rating of one conductor, None if the line is not
|
|
2389
|
+
found or has none.
|
|
2390
|
+
"""
|
|
2391
|
+
try:
|
|
2392
|
+
rating = float(
|
|
2393
|
+
self.network.line.loc[
|
|
2394
|
+
self.network.line.name == line_id, "max_i_ka"
|
|
2395
|
+
].iloc[0]
|
|
2396
|
+
)
|
|
2397
|
+
except (IndexError, KeyError, AttributeError, TypeError, ValueError):
|
|
2398
|
+
return None
|
|
2399
|
+
return rating * 1000.0 if rating > 0.0 else None
|
|
2400
|
+
|
|
2401
|
+
def get_line_base_impedance(self, line_id: int | str) -> float:
|
|
2402
|
+
"""
|
|
2403
|
+
Get the per-unit base impedance (ohm) of a line, from its from-bus voltage and the network base power.
|
|
2404
|
+
"""
|
|
2405
|
+
line = self.network.line.loc[self.network.line.name == line_id].iloc[0]
|
|
2406
|
+
vn_kv = float(self.network.bus.at[int(line.from_bus), "vn_kv"])
|
|
2407
|
+
return vn_kv**2 / float(self.network.sn_mva)
|
|
2408
|
+
|
|
2409
|
+
def get_transformer_type(self, transformer_id: str) -> str:
|
|
2410
|
+
"""
|
|
2411
|
+
Returns the type of a transformer based on the provided transformer ID.
|
|
2412
|
+
|
|
2413
|
+
Args:
|
|
2414
|
+
transformer_id (str): The unique identifier (name) of the transformer.
|
|
2415
|
+
|
|
2416
|
+
Returns:
|
|
2417
|
+
str: The standard type of the transformer.
|
|
2418
|
+
|
|
2419
|
+
Raises:
|
|
2420
|
+
ValueError: If the network is not initialized or if the transformer is not found.
|
|
2421
|
+
"""
|
|
2422
|
+
if self.network is None:
|
|
2423
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
2424
|
+
|
|
2425
|
+
try:
|
|
2426
|
+
# Find the line with the given name and return the standard type of the line
|
|
2427
|
+
return self.network.trafo.loc[
|
|
2428
|
+
self.network.trafo.name == transformer_id, "std_type"
|
|
2429
|
+
].iloc[0]
|
|
2430
|
+
except (IndexError, KeyError):
|
|
2431
|
+
self.logger.error(
|
|
2432
|
+
f"Transformer with name '{transformer_id}' not found in the network"
|
|
2433
|
+
)
|
|
2434
|
+
raise ValueError(
|
|
2435
|
+
f"Transformer with name '{transformer_id}' not found in the network"
|
|
2436
|
+
)
|
|
2437
|
+
|
|
2438
|
+
def get_transformer_types_in_place(self) -> set[str | None]:
|
|
2439
|
+
"""
|
|
2440
|
+
Get the standard types of the transformers in service of the network, None for
|
|
2441
|
+
those that have no type: a `std_type` of None, NaN or '', as pandapower writes
|
|
2442
|
+
it for a unit created from its parameters.
|
|
2443
|
+
"""
|
|
2444
|
+
if self.network is None or "std_type" not in self.network.trafo:
|
|
2445
|
+
return set()
|
|
2446
|
+
trafo = self.network.trafo
|
|
2447
|
+
types = trafo.std_type[trafo.in_service.astype(bool)]
|
|
2448
|
+
return {t if isinstance(t, str) and t else None for t in types.unique()}
|
|
2449
|
+
|
|
2450
|
+
def get_transformers_info(self) -> pd.DataFrame:
|
|
2451
|
+
"""
|
|
2452
|
+
Type (`std_type`, as the table holds it) and number of units in parallel
|
|
2453
|
+
(`parallel`) of the two-winding transformers, in service or not, indexed by
|
|
2454
|
+
name.
|
|
2455
|
+
"""
|
|
2456
|
+
trafo = self.network.trafo
|
|
2457
|
+
info = pd.DataFrame(
|
|
2458
|
+
{
|
|
2459
|
+
"std_type": trafo["std_type"].to_numpy()
|
|
2460
|
+
if "std_type" in trafo
|
|
2461
|
+
else None,
|
|
2462
|
+
"parallel": trafo["parallel"].to_numpy() if "parallel" in trafo else 1,
|
|
2463
|
+
},
|
|
2464
|
+
index=trafo["name"].to_numpy(),
|
|
2465
|
+
)
|
|
2466
|
+
return info
|
|
2467
|
+
|
|
2468
|
+
def get_transformer_parallel(self, transformer_id: str) -> int:
|
|
2469
|
+
"""
|
|
2470
|
+
Get the number of parallel units of a transformer (1 for a single unit).
|
|
2471
|
+
"""
|
|
2472
|
+
try:
|
|
2473
|
+
return int(
|
|
2474
|
+
self.network.trafo.loc[
|
|
2475
|
+
self.network.trafo.name == transformer_id, "parallel"
|
|
2476
|
+
].iloc[0]
|
|
2477
|
+
)
|
|
2478
|
+
except (IndexError, KeyError):
|
|
2479
|
+
return 1
|
|
2480
|
+
|
|
2481
|
+
def get_transformer_rating(self, transformer_id: str) -> float | None:
|
|
2482
|
+
"""
|
|
2483
|
+
Get the rating (VA) of one unit of a transformer, as the transformer table
|
|
2484
|
+
holds it, whether or not the unit has a catalogued type.
|
|
2485
|
+
|
|
2486
|
+
Returns:
|
|
2487
|
+
Optional[float]: The rating of one unit (`sn_mva`, not multiplied by the
|
|
2488
|
+
parallel units), or None if the transformer is not found.
|
|
2489
|
+
"""
|
|
2490
|
+
try:
|
|
2491
|
+
return float(
|
|
2492
|
+
self.network.trafo.loc[
|
|
2493
|
+
self.network.trafo.name == transformer_id, "sn_mva"
|
|
2494
|
+
].iloc[0]
|
|
2495
|
+
* 1.0e6
|
|
2496
|
+
)
|
|
2497
|
+
except (IndexError, KeyError, AttributeError):
|
|
2498
|
+
return None
|
|
2499
|
+
|
|
2500
|
+
def get_transformer_max_power(self, transformer_type: str) -> float:
|
|
2501
|
+
"""
|
|
2502
|
+
Retrieves the maximum power rating of a specified transformer type.
|
|
2503
|
+
|
|
2504
|
+
This method returns the maximum power rating (in VA) for the requested transformer type
|
|
2505
|
+
by looking up the standard type information in the PandaPower network model.
|
|
2506
|
+
|
|
2507
|
+
Args:
|
|
2508
|
+
transformer_type (str): The type of the transformer for which the maximum power rating has to be determined.
|
|
2509
|
+
|
|
2510
|
+
Returns:
|
|
2511
|
+
float: The maximum power rating for the specified transformer type in VA.
|
|
2512
|
+
|
|
2513
|
+
Raises:
|
|
2514
|
+
ValueError: If the transformer type is not found in the standard types.
|
|
2515
|
+
"""
|
|
2516
|
+
if self.network is None:
|
|
2517
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
2518
|
+
|
|
2519
|
+
try:
|
|
2520
|
+
# Look up the transformer type in the standard types dictionary
|
|
2521
|
+
trafo_std_type = self.network.std_types["trafo"][transformer_type]
|
|
2522
|
+
except KeyError:
|
|
2523
|
+
self.logger.debug(
|
|
2524
|
+
f"Transformer type '{transformer_type}' not found in standard types"
|
|
2525
|
+
)
|
|
2526
|
+
raise ValueError(
|
|
2527
|
+
f"Transformer type '{transformer_type}' not found in standard types"
|
|
2528
|
+
)
|
|
2529
|
+
|
|
2530
|
+
# PandaPower stores transformer ratings in MVA, convert to VA
|
|
2531
|
+
return trafo_std_type["sn_mva"] * 1.0e6 # Convert MVA to VA
|
|
2532
|
+
|
|
2533
|
+
def partition_network(self) -> dict[int, Any]:
|
|
2534
|
+
"""
|
|
2535
|
+
Partition the network into galvanically connected components.
|
|
2536
|
+
|
|
2537
|
+
This method identifies separate electrical areas in the network that are not
|
|
2538
|
+
connected to each other by power lines or other conducting elements, but can
|
|
2539
|
+
be connected by transformers.
|
|
2540
|
+
|
|
2541
|
+
Returns:
|
|
2542
|
+
Dict[int, Any]: Dictionary mapping component IDs to lists of elements (buses, lines, etc.)
|
|
2543
|
+
in each connected component.
|
|
2544
|
+
"""
|
|
2545
|
+
if not self.network:
|
|
2546
|
+
raise ValueError("No network loaded")
|
|
2547
|
+
|
|
2548
|
+
try:
|
|
2549
|
+
import networkx as nx
|
|
2550
|
+
from pandapower.topology import create_nxgraph
|
|
2551
|
+
except ImportError:
|
|
2552
|
+
self.logger.error(
|
|
2553
|
+
"NetworkX is required for network partitioning but not installed"
|
|
2554
|
+
)
|
|
2555
|
+
raise ImportError("NetworkX is required for network partitioning")
|
|
2556
|
+
|
|
2557
|
+
net = self.network
|
|
2558
|
+
# Undirected graph of the network without transformers: galvanic connections
|
|
2559
|
+
G = create_nxgraph(net, include_trafos=False)
|
|
2560
|
+
component_of_bus: dict[int, int] = {}
|
|
2561
|
+
for i, component in enumerate(nx.connected_components(G)):
|
|
2562
|
+
for bus in component:
|
|
2563
|
+
component_of_bus[int(bus)] = i + 1 # component IDs start from 1
|
|
2564
|
+
n_components = len(set(component_of_bus.values()))
|
|
2565
|
+
|
|
2566
|
+
result = {
|
|
2567
|
+
component_id: {
|
|
2568
|
+
"buses": [],
|
|
2569
|
+
"lines": [],
|
|
2570
|
+
"transformers": [],
|
|
2571
|
+
"loads": [],
|
|
2572
|
+
"generators": [],
|
|
2573
|
+
"static_generators": [],
|
|
2574
|
+
}
|
|
2575
|
+
for component_id in range(1, n_components + 1)
|
|
2576
|
+
}
|
|
2577
|
+
|
|
2578
|
+
def comp(bus_values):
|
|
2579
|
+
return pd.Series(bus_values).map(component_of_bus)
|
|
2580
|
+
|
|
2581
|
+
bus_comp = comp(net.bus.index.to_numpy())
|
|
2582
|
+
for name, c in zip(net.bus["name"], bus_comp, strict=True):
|
|
2583
|
+
if pd.notna(c):
|
|
2584
|
+
result[int(c)]["buses"].append(name)
|
|
2585
|
+
|
|
2586
|
+
if not net.line.empty:
|
|
2587
|
+
c_from = comp(net.line["from_bus"].to_numpy())
|
|
2588
|
+
c_to = comp(net.line["to_bus"].to_numpy())
|
|
2589
|
+
same = (c_from == c_to) & c_from.notna()
|
|
2590
|
+
for name, c in zip(
|
|
2591
|
+
net.line["name"][same.to_numpy()], c_from[same], strict=False
|
|
2592
|
+
):
|
|
2593
|
+
result[int(c)]["lines"].append(name)
|
|
2594
|
+
|
|
2595
|
+
for table, key, bus_col in (
|
|
2596
|
+
("trafo", "transformers", "lv_bus"),
|
|
2597
|
+
("load", "loads", "bus"),
|
|
2598
|
+
("gen", "generators", "bus"),
|
|
2599
|
+
("sgen", "static_generators", "bus"),
|
|
2600
|
+
):
|
|
2601
|
+
df = getattr(net, table, None)
|
|
2602
|
+
if df is None or df.empty:
|
|
2603
|
+
continue
|
|
2604
|
+
c = comp(df[bus_col].to_numpy())
|
|
2605
|
+
for name, ci in zip(df["name"], c, strict=True):
|
|
2606
|
+
if pd.notna(ci):
|
|
2607
|
+
result[int(ci)][key].append(name)
|
|
2608
|
+
|
|
2609
|
+
self.logger.info(
|
|
2610
|
+
f"Network partitioned into {len(result)} galvanically connected components"
|
|
2611
|
+
)
|
|
2612
|
+
self.network_partition = result
|
|
2613
|
+
return result
|
|
2614
|
+
|
|
2615
|
+
def get_voltage_magnitude_range(self, component_id: int) -> dict[str, float]:
|
|
2616
|
+
"""
|
|
2617
|
+
Get the minimum and maximum voltage magnitudes in a specific network component.
|
|
2618
|
+
|
|
2619
|
+
This method determines the voltage magnitude bounds within a given network
|
|
2620
|
+
component identified by its component_id.
|
|
2621
|
+
|
|
2622
|
+
Args:
|
|
2623
|
+
component_id (int): The ID of the component to analyze.
|
|
2624
|
+
|
|
2625
|
+
Returns:
|
|
2626
|
+
Dict[str, float]: Dictionary containing 'min' and 'max' voltage magnitude values in per unit.
|
|
2627
|
+
|
|
2628
|
+
Raises:
|
|
2629
|
+
ValueError: If the network is not initialized, power flow hasn't been run,
|
|
2630
|
+
or if the component ID is invalid.
|
|
2631
|
+
"""
|
|
2632
|
+
if self.network is None:
|
|
2633
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
2634
|
+
|
|
2635
|
+
if not self.latest_results or not self.latest_results.get("converged", False):
|
|
2636
|
+
raise ValueError(
|
|
2637
|
+
"Need a converged power flow solution to get voltage magnitudes"
|
|
2638
|
+
)
|
|
2639
|
+
|
|
2640
|
+
if self.network_partition is None:
|
|
2641
|
+
self.logger.info("Network not yet partitioned. Partitioning now.")
|
|
2642
|
+
self.partition_network()
|
|
2643
|
+
|
|
2644
|
+
if component_id not in self.network_partition:
|
|
2645
|
+
raise ValueError(
|
|
2646
|
+
f"Component ID {component_id} not found in network partition"
|
|
2647
|
+
)
|
|
2648
|
+
|
|
2649
|
+
# Get all bus names in the component
|
|
2650
|
+
component_buses = self.network_partition[component_id]["buses"]
|
|
2651
|
+
|
|
2652
|
+
if not component_buses:
|
|
2653
|
+
raise ValueError(f"No buses found in component {component_id}")
|
|
2654
|
+
|
|
2655
|
+
# Create a mask for buses in this component
|
|
2656
|
+
mask = self.network.bus["name"].isin(component_buses)
|
|
2657
|
+
|
|
2658
|
+
# Get indices of buses in this component
|
|
2659
|
+
bus_indices = self.network.bus.loc[mask].index
|
|
2660
|
+
|
|
2661
|
+
if len(bus_indices) == 0:
|
|
2662
|
+
raise ValueError(f"No matching buses found for component {component_id}")
|
|
2663
|
+
|
|
2664
|
+
# Extract voltage magnitudes for these buses
|
|
2665
|
+
voltage_magnitudes = self.network.res_bus.loc[bus_indices, "vm_pu"]
|
|
2666
|
+
|
|
2667
|
+
# Return min and max values
|
|
2668
|
+
return {
|
|
2669
|
+
"min": float(voltage_magnitudes.min()),
|
|
2670
|
+
"max": float(voltage_magnitudes.max()),
|
|
2671
|
+
}
|
|
2672
|
+
|
|
2673
|
+
def get_transformer_tap_positions(self, transformer_id: int | str) -> np.ndarray:
|
|
2674
|
+
"""
|
|
2675
|
+
Get all available tap positions for a given transformer in per unit voltage values.
|
|
2676
|
+
|
|
2677
|
+
This method returns all possible tap positions that can be set for the specified
|
|
2678
|
+
transformer, expressed as per unit voltage values (e.g., [-0.05, -0.025, 0, 0.025, 0.05]).
|
|
2679
|
+
|
|
2680
|
+
Args:
|
|
2681
|
+
transformer_id (Union[int, str]): The ID of the transformer to get tap positions for.
|
|
2682
|
+
|
|
2683
|
+
Returns:
|
|
2684
|
+
np.ndarray: Array of all available tap positions as per unit voltage values,
|
|
2685
|
+
typically sorted from lowest to highest.
|
|
2686
|
+
|
|
2687
|
+
Raises:
|
|
2688
|
+
ValueError: If the transformer does not exist or if tap positions cannot be determined.
|
|
2689
|
+
"""
|
|
2690
|
+
if self.network is None:
|
|
2691
|
+
raise ValueError("Network not initialized. Create or load a network first.")
|
|
2692
|
+
|
|
2693
|
+
try:
|
|
2694
|
+
import numpy as np
|
|
2695
|
+
|
|
2696
|
+
# Find the transformer by name
|
|
2697
|
+
mask = self.network.trafo["name"] == transformer_id
|
|
2698
|
+
|
|
2699
|
+
if not any(mask):
|
|
2700
|
+
raise ValueError(
|
|
2701
|
+
f"Transformer with ID '{transformer_id}' not found in the network"
|
|
2702
|
+
)
|
|
2703
|
+
|
|
2704
|
+
# Get transformer parameters related to tap changing
|
|
2705
|
+
tap_min = self.network.trafo.loc[mask, "tap_min"].values[0]
|
|
2706
|
+
tap_max = self.network.trafo.loc[mask, "tap_max"].values[0]
|
|
2707
|
+
tap_step_percent = self.network.trafo.loc[mask, "tap_step_percent"].values[
|
|
2708
|
+
0
|
|
2709
|
+
]
|
|
2710
|
+
tap_neutral = self.network.trafo.loc[mask, "tap_neutral"].values[0]
|
|
2711
|
+
tap_side = self.network.trafo.loc[mask, "tap_side"].values[0]
|
|
2712
|
+
|
|
2713
|
+
# Create numpy array of all possible tap positions
|
|
2714
|
+
tap_positions = np.arange(int(tap_min), int(tap_max) + 1)
|
|
2715
|
+
|
|
2716
|
+
# Calculate per unit voltage change for each tap position
|
|
2717
|
+
step_pu = tap_step_percent / 100.0
|
|
2718
|
+
voltage_pu_changes = (tap_positions - tap_neutral) * step_pu
|
|
2719
|
+
|
|
2720
|
+
# For tap changer on the HV side, the voltage effect is inverted
|
|
2721
|
+
# when viewed from the LV side
|
|
2722
|
+
if tap_side == "hv":
|
|
2723
|
+
voltage_pu_changes = -voltage_pu_changes
|
|
2724
|
+
|
|
2725
|
+
# Round to avoid floating point precision issues
|
|
2726
|
+
return np.round(voltage_pu_changes, 6)
|
|
2727
|
+
|
|
2728
|
+
except Exception as e:
|
|
2729
|
+
self.logger.error(f"Failed to get transformer tap positions: {str(e)}")
|
|
2730
|
+
raise ValueError(
|
|
2731
|
+
f"Error retrieving tap positions for transformer '{transformer_id}': {str(e)}"
|
|
2732
|
+
)
|
|
2733
|
+
|
|
2734
|
+
def _jacobian_context(self) -> dict[str, Any]:
|
|
2735
|
+
"""
|
|
2736
|
+
Collect the converged Newton-Raphson state needed by the linearised voltage responses.
|
|
2737
|
+
"""
|
|
2738
|
+
net = self.network
|
|
2739
|
+
if not self._has_converged_results():
|
|
2740
|
+
raise RuntimeError(_NO_CONVERGED_RUN)
|
|
2741
|
+
if not self._tables_match_results():
|
|
2742
|
+
raise RuntimeError(_STALE_TABLES)
|
|
2743
|
+
if not hasattr(net, "_ppc") or net._ppc is None or "internal" not in net._ppc:
|
|
2744
|
+
raise RuntimeError(
|
|
2745
|
+
"Pandapower network internal PPC structure not available. Run a power flow."
|
|
2746
|
+
)
|
|
2747
|
+
ppc_int = net._ppc["internal"]
|
|
2748
|
+
pq = np.asarray(ppc_int.get("pq", []), dtype=int)
|
|
2749
|
+
pv = np.asarray(ppc_int.get("pv", []), dtype=int)
|
|
2750
|
+
J_sparse = self._converged_jacobian()
|
|
2751
|
+
if J_sparse is None or J_sparse.shape == (0, 0) or J_sparse.nnz == 0:
|
|
2752
|
+
raise ValueError(
|
|
2753
|
+
"Jacobian matrix J is not available or empty in net._ppc['internal']. Has a power flow been run with 'calculate_voltage_angles=True' and appropriate algorithm settings?"
|
|
2754
|
+
)
|
|
2755
|
+
V_complex = ppc_int.get("V")
|
|
2756
|
+
if V_complex is None:
|
|
2757
|
+
raise ValueError("Complex voltages 'V' not found in net._ppc['internal'].")
|
|
2758
|
+
n_p_eq = len(pv) + len(pq)
|
|
2759
|
+
n_q_eq = len(pq)
|
|
2760
|
+
if n_p_eq + n_q_eq == 0:
|
|
2761
|
+
raise ValueError(
|
|
2762
|
+
"No PQ or PV buses found for sensitivity calculation (excluding slack bus equations)."
|
|
2763
|
+
)
|
|
2764
|
+
if J_sparse.shape[0] != n_p_eq + n_q_eq:
|
|
2765
|
+
raise ValueError(
|
|
2766
|
+
f"Jacobian rows {J_sparse.shape[0]} do not match the number of equations {n_p_eq + n_q_eq}."
|
|
2767
|
+
)
|
|
2768
|
+
n_ppc = len(V_complex)
|
|
2769
|
+
# Equation ordering of the Newton-Raphson Jacobian: P rows for (pv, pq), Q rows for pq
|
|
2770
|
+
pos_p = np.full(n_ppc, -1, dtype=int)
|
|
2771
|
+
pos_p[np.concatenate([pv, pq])] = np.arange(n_p_eq)
|
|
2772
|
+
pos_q = np.full(n_ppc, -1, dtype=int)
|
|
2773
|
+
pos_q[pq] = np.arange(n_q_eq)
|
|
2774
|
+
return {
|
|
2775
|
+
"J": J_sparse,
|
|
2776
|
+
"V": V_complex,
|
|
2777
|
+
"n_ppc": n_ppc,
|
|
2778
|
+
"n_p_eq": n_p_eq,
|
|
2779
|
+
"n_q_eq": n_q_eq,
|
|
2780
|
+
"pos_p": pos_p,
|
|
2781
|
+
"pos_q": pos_q,
|
|
2782
|
+
"bus_lookup": np.asarray(net._pd2ppc_lookups["bus"]),
|
|
2783
|
+
}
|
|
2784
|
+
|
|
2785
|
+
def _select_lines(self, line_names: list[str] | None) -> pd.DataFrame:
|
|
2786
|
+
"""
|
|
2787
|
+
Lines that conduct: in service, with no open line switch at either end, and between
|
|
2788
|
+
two buses that are in service and supplied.
|
|
2789
|
+
|
|
2790
|
+
A line opened by a switch (a normally-open point, for instance) carries no
|
|
2791
|
+
current, so changing it changes no voltage and it is on no path to a source. The
|
|
2792
|
+
same goes for a line to a bus out of service, and for one in an island that no
|
|
2793
|
+
external grid reaches (through lines, transformers and closed switches), which
|
|
2794
|
+
pandapower leaves without a solution.
|
|
2795
|
+
"""
|
|
2796
|
+
lines = self.network.line
|
|
2797
|
+
if "in_service" in lines.columns:
|
|
2798
|
+
lines = lines[lines["in_service"].astype(bool)]
|
|
2799
|
+
switches = self.network.switch
|
|
2800
|
+
if not switches.empty:
|
|
2801
|
+
opened = switches.loc[
|
|
2802
|
+
(switches["et"] == "l") & ~switches["closed"].astype(bool), "element"
|
|
2803
|
+
]
|
|
2804
|
+
if not opened.empty:
|
|
2805
|
+
lines = lines[~lines.index.isin(opened)]
|
|
2806
|
+
if not lines.empty:
|
|
2807
|
+
dead = self._dead_buses()
|
|
2808
|
+
if dead:
|
|
2809
|
+
lines = lines[
|
|
2810
|
+
~(lines["from_bus"].isin(dead) | lines["to_bus"].isin(dead))
|
|
2811
|
+
]
|
|
2812
|
+
if line_names is not None:
|
|
2813
|
+
lines = lines[lines["name"].isin(line_names)]
|
|
2814
|
+
return lines
|
|
2815
|
+
|
|
2816
|
+
def _dead_buses(self) -> frozenset[int]:
|
|
2817
|
+
"""
|
|
2818
|
+
Indices of the buses that no line can connect to a solution: those out of service
|
|
2819
|
+
and those of an island with no source (no external grid, in service, reaches them).
|
|
2820
|
+
|
|
2821
|
+
Finding the islands builds pandapower's topology graph, which takes a few
|
|
2822
|
+
milliseconds on a feeder, more than the rest of `_select_lines`. The result is
|
|
2823
|
+
kept with the topology it was found in (`_topology_key`), and found again only
|
|
2824
|
+
when that topology has changed, whether a power flow was run since or not: a
|
|
2825
|
+
bus put out of service or a switch opened between two calls is seen at once.
|
|
2826
|
+
"""
|
|
2827
|
+
key = self._topology_key()
|
|
2828
|
+
if self._dead_buses_cache is not None and self._dead_buses_cache[0] == key:
|
|
2829
|
+
return self._dead_buses_cache[1]
|
|
2830
|
+
|
|
2831
|
+
# Imported here, as the other uses of the topology module of pandapower
|
|
2832
|
+
import pandapower.topology as ppt
|
|
2833
|
+
|
|
2834
|
+
net = self.network
|
|
2835
|
+
in_service = net.bus["in_service"].astype(bool)
|
|
2836
|
+
dead = frozenset(int(bus) for bus in net.bus.index[~in_service]) | frozenset(
|
|
2837
|
+
int(bus) for bus in ppt.unsupplied_buses(net)
|
|
2838
|
+
)
|
|
2839
|
+
self._dead_buses_cache = (key, dead)
|
|
2840
|
+
return dead
|
|
2841
|
+
|
|
2842
|
+
def _topology_key(self) -> tuple:
|
|
2843
|
+
"""
|
|
2844
|
+
What the topology graph of the network is built from (`_TOPOLOGY_TABLES`,
|
|
2845
|
+
`_TOPOLOGY_COLUMNS`): equal keys give the same dead buses. About 0.05 ms on the
|
|
2846
|
+
largest feeder.
|
|
2847
|
+
"""
|
|
2848
|
+
net = self.network
|
|
2849
|
+
parts: list[Any] = []
|
|
2850
|
+
for name in _TOPOLOGY_TABLES:
|
|
2851
|
+
table = net.get(name)
|
|
2852
|
+
if not isinstance(table, pd.DataFrame) or len(table.index) == 0:
|
|
2853
|
+
continue
|
|
2854
|
+
present = set(table.columns)
|
|
2855
|
+
columns = [c for c in _TOPOLOGY_COLUMNS if c in present]
|
|
2856
|
+
for label, values in zip(
|
|
2857
|
+
[name, *columns],
|
|
2858
|
+
[table.index.to_numpy(), *(table[c].to_numpy() for c in columns)],
|
|
2859
|
+
strict=True,
|
|
2860
|
+
):
|
|
2861
|
+
if values.dtype.kind in "biuf":
|
|
2862
|
+
parts.append((label, values.dtype.str, values.tobytes()))
|
|
2863
|
+
else:
|
|
2864
|
+
parts.append((label, tuple(values.tolist())))
|
|
2865
|
+
return tuple(parts)
|
|
2866
|
+
|
|
2867
|
+
def _line_pu_parameters(
|
|
2868
|
+
self, lines: pd.DataFrame
|
|
2869
|
+
) -> tuple[np.ndarray, np.ndarray, np.ndarray]:
|
|
2870
|
+
"""
|
|
2871
|
+
Equivalent (parallel-combined) per-unit series resistance and reactance of `lines`, and z_base.
|
|
2872
|
+
"""
|
|
2873
|
+
net = self.network
|
|
2874
|
+
f_pd = lines["from_bus"].to_numpy(dtype=int)
|
|
2875
|
+
v_base = (
|
|
2876
|
+
net.bus["vn_kv"].to_numpy(dtype=float)[net.bus.index.get_indexer(f_pd)]
|
|
2877
|
+
* 1e3
|
|
2878
|
+
)
|
|
2879
|
+
z_base = v_base**2 / (net.sn_mva * 1e6)
|
|
2880
|
+
parallel = (
|
|
2881
|
+
lines["parallel"].to_numpy(dtype=float)
|
|
2882
|
+
if "parallel" in lines.columns
|
|
2883
|
+
else 1.0
|
|
2884
|
+
)
|
|
2885
|
+
length = lines["length_km"].to_numpy(dtype=float)
|
|
2886
|
+
r_pu = lines["r_ohm_per_km"].to_numpy(dtype=float) * length / parallel / z_base
|
|
2887
|
+
x_pu = lines["x_ohm_per_km"].to_numpy(dtype=float) * length / parallel / z_base
|
|
2888
|
+
return r_pu, x_pu, z_base
|
|
2889
|
+
|
|
2890
|
+
def _voltage_response(
|
|
2891
|
+
self,
|
|
2892
|
+
lines: pd.DataFrame,
|
|
2893
|
+
dG: np.ndarray,
|
|
2894
|
+
dB: np.ndarray,
|
|
2895
|
+
ctx: dict[str, Any],
|
|
2896
|
+
buses: list[str] | None = None,
|
|
2897
|
+
) -> pd.DataFrame:
|
|
2898
|
+
"""
|
|
2899
|
+
Linearised voltage-magnitude response (one column per line) to a change (dG, dB) of each
|
|
2900
|
+
line's series admittance: dx = -J^-1 dS, with dS the induced change of the bus mismatches.
|
|
2901
|
+
|
|
2902
|
+
When `buses` is given, only those rows are computed, through the transposed system
|
|
2903
|
+
J^T Y = E (one right-hand side per requested bus), which is much cheaper than a full
|
|
2904
|
+
solve when few buses are of interest.
|
|
2905
|
+
"""
|
|
2906
|
+
net = self.network
|
|
2907
|
+
V_complex, bus_lookup, n_ppc = ctx["V"], ctx["bus_lookup"], ctx["n_ppc"]
|
|
2908
|
+
n_p_eq, pos_p, pos_q = ctx["n_p_eq"], ctx["pos_p"], ctx["pos_q"]
|
|
2909
|
+
f_ppc = bus_lookup[lines["from_bus"].to_numpy(dtype=int)]
|
|
2910
|
+
t_ppc = bus_lookup[lines["to_bus"].to_numpy(dtype=int)]
|
|
2911
|
+
valid = (f_ppc >= 0) & (f_ppc < n_ppc) & (t_ppc >= 0) & (t_ppc < n_ppc)
|
|
2912
|
+
if not valid.all():
|
|
2913
|
+
self.logger.warning(
|
|
2914
|
+
f"{(~valid).sum()} lines skipped in the sensitivity computation (buses not in the ppc)."
|
|
2915
|
+
)
|
|
2916
|
+
lines, dG, dB = lines[valid], dG[valid], dB[valid]
|
|
2917
|
+
f_ppc, t_ppc = f_ppc[valid], t_ppc[valid]
|
|
2918
|
+
Vi = np.abs(V_complex[f_ppc])
|
|
2919
|
+
Vj = np.abs(V_complex[t_ppc])
|
|
2920
|
+
delta = np.angle(V_complex[f_ppc]) - np.angle(V_complex[t_ppc])
|
|
2921
|
+
cos_d, sin_d = np.cos(delta), np.sin(delta)
|
|
2922
|
+
dP_f = Vi**2 * dG - Vi * Vj * (dG * cos_d + dB * sin_d)
|
|
2923
|
+
dQ_f = -(Vi**2) * dB - Vi * Vj * (dG * sin_d - dB * cos_d)
|
|
2924
|
+
dP_t = Vj**2 * dG - Vi * Vj * (dG * cos_d - dB * sin_d)
|
|
2925
|
+
dQ_t = -(Vj**2) * dB + Vi * Vj * (dG * sin_d + dB * cos_d)
|
|
2926
|
+
|
|
2927
|
+
n_ln = len(lines)
|
|
2928
|
+
n_eq = ctx["n_p_eq"] + ctx["n_q_eq"]
|
|
2929
|
+
cols = np.arange(n_ln)
|
|
2930
|
+
rows_list, cols_list, vals_list = [], [], []
|
|
2931
|
+
for ppc_idx, values, pos, offset in (
|
|
2932
|
+
(f_ppc, dP_f, pos_p, 0),
|
|
2933
|
+
(t_ppc, dP_t, pos_p, 0),
|
|
2934
|
+
(f_ppc, dQ_f, pos_q, n_p_eq),
|
|
2935
|
+
(t_ppc, dQ_t, pos_q, n_p_eq),
|
|
2936
|
+
):
|
|
2937
|
+
rows = pos[ppc_idx]
|
|
2938
|
+
m = rows >= 0
|
|
2939
|
+
rows_list.append(rows[m] + offset)
|
|
2940
|
+
cols_list.append(cols[m])
|
|
2941
|
+
vals_list.append(values[m])
|
|
2942
|
+
dS = sparse.coo_matrix(
|
|
2943
|
+
(
|
|
2944
|
+
np.concatenate(vals_list),
|
|
2945
|
+
(np.concatenate(rows_list), np.concatenate(cols_list)),
|
|
2946
|
+
),
|
|
2947
|
+
shape=(n_eq, n_ln),
|
|
2948
|
+
).tocsc()
|
|
2949
|
+
|
|
2950
|
+
if buses is None:
|
|
2951
|
+
bus_names = net.bus.name.tolist()
|
|
2952
|
+
bus_pd = net.bus.index.to_numpy(dtype=int)
|
|
2953
|
+
else:
|
|
2954
|
+
name_to_idx = pd.Series(
|
|
2955
|
+
net.bus.index.to_numpy(dtype=int), index=net.bus["name"]
|
|
2956
|
+
)
|
|
2957
|
+
bus_names = [b for b in buses if b in name_to_idx.index]
|
|
2958
|
+
bus_pd = name_to_idx.loc[bus_names].to_numpy(dtype=int)
|
|
2959
|
+
bus_ppc = bus_lookup[bus_pd]
|
|
2960
|
+
ok = (bus_ppc >= 0) & (bus_ppc < n_ppc)
|
|
2961
|
+
q_rows = np.full(len(bus_pd), -1, dtype=int)
|
|
2962
|
+
q_rows[ok] = pos_q[bus_ppc[ok]]
|
|
2963
|
+
has_q = q_rows >= 0
|
|
2964
|
+
result = np.zeros((len(bus_pd), n_ln))
|
|
2965
|
+
|
|
2966
|
+
# The factors of the Jacobian are those of the other sensitivities of this
|
|
2967
|
+
# solution: both systems below are solved from them, without a factorisation.
|
|
2968
|
+
lu = self._jacobian_lu(ctx["J"])
|
|
2969
|
+
if buses is None or has_q.sum() > n_ln:
|
|
2970
|
+
dx = -lu.solve(dS.toarray())
|
|
2971
|
+
dVmag_pq = dx[n_p_eq:, :] # rows ordered like `pq`
|
|
2972
|
+
result[has_q, :] = dVmag_pq[q_rows[has_q], :]
|
|
2973
|
+
elif has_q.any():
|
|
2974
|
+
# rows of J^-1 for the requested PQ buses: J^T Y = E
|
|
2975
|
+
E = np.zeros((n_eq, int(has_q.sum())))
|
|
2976
|
+
E[n_p_eq + q_rows[has_q], np.arange(int(has_q.sum()))] = 1.0
|
|
2977
|
+
Y = lu.solve(E, trans="T") # n_eq x n_b
|
|
2978
|
+
result[has_q, :] = -(dS.T @ Y).T
|
|
2979
|
+
return pd.DataFrame(result, index=bus_names, columns=lines["name"].tolist())
|
|
2980
|
+
|
|
2981
|
+
def calculate_voltage_line_resistance_sensitivities(
|
|
2982
|
+
self, line_names: list[str] | None = None
|
|
2983
|
+
) -> pd.DataFrame:
|
|
2984
|
+
"""
|
|
2985
|
+
Computes the sensitivity of bus voltage magnitudes to small changes in line RESISTANCE (r_pu)
|
|
2986
|
+
using the inverse of the Jacobian matrix from pandapower's power flow solution.
|
|
2987
|
+
|
|
2988
|
+
The computation is vectorised over the lines and can be restricted to a subset of lines,
|
|
2989
|
+
which keeps it cheap on large feeders when only one galvanic zone is of interest.
|
|
2990
|
+
|
|
2991
|
+
The voltage-dependent share of the loads (``const_i_*_percent``,
|
|
2992
|
+
``const_z_*_percent``) is not in this Jacobian: see the limit in
|
|
2993
|
+
`calculate_voltage_power_sensitivities`.
|
|
2994
|
+
|
|
2995
|
+
Args:
|
|
2996
|
+
line_names (Optional[List[str]], optional): Names of the lines to consider. Defaults to
|
|
2997
|
+
all lines that conduct.
|
|
2998
|
+
|
|
2999
|
+
Returns:
|
|
3000
|
+
pd.DataFrame: DataFrame with bus names as index and line names as columns.
|
|
3001
|
+
Each value represents dV_mag_pu / dr_line_pu (equivalent resistance of
|
|
3002
|
+
the parallel-combined line).
|
|
3003
|
+
|
|
3004
|
+
Raises:
|
|
3005
|
+
RuntimeError: If there is no converged run of the engine (`run_power_flow`;
|
|
3006
|
+
the results of `pp.runpp` are not used), or if a bus, a line or a
|
|
3007
|
+
transformer has been created or dropped since the last one.
|
|
3008
|
+
"""
|
|
3009
|
+
ctx = self._jacobian_context()
|
|
3010
|
+
lines = self._select_lines(line_names)
|
|
3011
|
+
if lines.empty:
|
|
3012
|
+
return pd.DataFrame(0.0, index=self.network.bus.name.tolist(), columns=[])
|
|
3013
|
+
r_pu, x_pu, _ = self._line_pu_parameters(lines)
|
|
3014
|
+
z2_pu = r_pu**2 + x_pu**2
|
|
3015
|
+
zero = np.isclose(z2_pu, 0.0, rtol=0, atol=1.0e-15)
|
|
3016
|
+
if zero.any():
|
|
3017
|
+
raise ValueError(
|
|
3018
|
+
f"Per unit impedance squared (z2_pu) is zero for lines {lines['name'].to_numpy()[zero][:5]}."
|
|
3019
|
+
)
|
|
3020
|
+
dG_dr = (x_pu**2 - r_pu**2) / z2_pu**2
|
|
3021
|
+
dB_dr = (2.0 * r_pu * x_pu) / z2_pu**2
|
|
3022
|
+
return self._voltage_response(lines, dG_dr, dB_dr, ctx)
|
|
3023
|
+
|
|
3024
|
+
def calculate_voltage_line_change_effects(
|
|
3025
|
+
self,
|
|
3026
|
+
changes: dict[str, tuple[float, float, int]],
|
|
3027
|
+
buses: list[str] | None = None,
|
|
3028
|
+
) -> pd.DataFrame:
|
|
3029
|
+
"""
|
|
3030
|
+
Predict the bus voltage-magnitude change (p.u.) brought by a finite change of each line.
|
|
3031
|
+
|
|
3032
|
+
Unlike the resistance sensitivity, the response is linearised in the finite change of
|
|
3033
|
+
the series impedance (r and x of the parallel-combined line) with one Newton step, so
|
|
3034
|
+
the prediction stays accurate for large steps (a new conductor type, one more parallel
|
|
3035
|
+
conductor) on radial feeders, where the voltage drop is nearly linear in impedance.
|
|
3036
|
+
|
|
3037
|
+
The voltage-dependent share of the loads (``const_i_*_percent``,
|
|
3038
|
+
``const_z_*_percent``) is not in this Jacobian: see the limit in
|
|
3039
|
+
`calculate_voltage_power_sensitivities`.
|
|
3040
|
+
|
|
3041
|
+
Args:
|
|
3042
|
+
changes (Dict[str, Tuple[float, float, int]]): line name -> (new r_ohm_per_km,
|
|
3043
|
+
new x_ohm_per_km, new parallel count).
|
|
3044
|
+
buses (Optional[List[str]], optional): Only compute the response at these buses.
|
|
3045
|
+
|
|
3046
|
+
Returns:
|
|
3047
|
+
pd.DataFrame: index = bus names, columns = names of the lines of `changes`
|
|
3048
|
+
that conduct (in service, no open line switch, between buses in
|
|
3049
|
+
service and supplied) between buses of the
|
|
3050
|
+
solution, values = predicted dV (p.u.). A line without series impedance,
|
|
3051
|
+
like one of zero length, has no voltage drop to change: its column is 0.
|
|
3052
|
+
|
|
3053
|
+
Raises:
|
|
3054
|
+
RuntimeError: If there is no converged run of the engine (`run_power_flow`;
|
|
3055
|
+
the results of `pp.runpp` are not used), or if a bus, a line or a
|
|
3056
|
+
transformer has been created or dropped since the last one.
|
|
3057
|
+
"""
|
|
3058
|
+
lines = self._select_lines(list(changes)) if changes else None
|
|
3059
|
+
if lines is None or lines.empty:
|
|
3060
|
+
return pd.DataFrame(
|
|
3061
|
+
0.0,
|
|
3062
|
+
index=self.network.bus.name.tolist() if buses is None else buses,
|
|
3063
|
+
columns=[],
|
|
3064
|
+
)
|
|
3065
|
+
ctx = self._jacobian_context()
|
|
3066
|
+
new = np.array([changes[name] for name in lines["name"]], dtype=float)
|
|
3067
|
+
dy = self._line_change_admittance(lines, new)
|
|
3068
|
+
return self._voltage_response(lines, dy.real, dy.imag, ctx, buses=buses)
|
|
3069
|
+
|
|
3070
|
+
def calculate_voltage_line_change_effects_of_steps(
|
|
3071
|
+
self,
|
|
3072
|
+
steps: list[tuple[str, float, float, int]],
|
|
3073
|
+
buses: list[str] | None = None,
|
|
3074
|
+
) -> pd.DataFrame:
|
|
3075
|
+
"""
|
|
3076
|
+
Predicted bus voltage-magnitude change (p.u.) for each of `steps`, each a finite
|
|
3077
|
+
change of one line taken alone: (line name, new r_ohm_per_km, new x_ohm_per_km,
|
|
3078
|
+
new parallel count), several steps of a line allowed.
|
|
3079
|
+
|
|
3080
|
+
Each step is a column of the response of `calculate_voltage_line_change_effects`,
|
|
3081
|
+
computed from the same factors of the Jacobian, and the column of a step does not
|
|
3082
|
+
depend on the other steps: all are predicted with one solve, whatever the number
|
|
3083
|
+
of steps a line has.
|
|
3084
|
+
|
|
3085
|
+
Returns:
|
|
3086
|
+
pd.DataFrame: index = bus names, or `buses` when given; columns = the
|
|
3087
|
+
positions in `steps` of the steps whose line conducts (see
|
|
3088
|
+
`calculate_voltage_line_change_effects`), in order.
|
|
3089
|
+
|
|
3090
|
+
Raises:
|
|
3091
|
+
RuntimeError: As `calculate_voltage_line_change_effects`.
|
|
3092
|
+
"""
|
|
3093
|
+
names = list(dict.fromkeys(step[0] for step in steps))
|
|
3094
|
+
lines = self._select_lines(names) if steps else None
|
|
3095
|
+
if lines is None or lines.empty:
|
|
3096
|
+
return pd.DataFrame(
|
|
3097
|
+
0.0,
|
|
3098
|
+
index=self.network.bus.name.tolist() if buses is None else buses,
|
|
3099
|
+
columns=[],
|
|
3100
|
+
)
|
|
3101
|
+
ctx = self._jacobian_context()
|
|
3102
|
+
row_of = {name: i for i, name in enumerate(lines["name"])}
|
|
3103
|
+
# The steps of the lines between buses of the solution, as
|
|
3104
|
+
# `_voltage_response` keeps them
|
|
3105
|
+
bus_lookup, n_ppc = ctx["bus_lookup"], ctx["n_ppc"]
|
|
3106
|
+
f_ppc = bus_lookup[lines["from_bus"].to_numpy(dtype=int)]
|
|
3107
|
+
t_ppc = bus_lookup[lines["to_bus"].to_numpy(dtype=int)]
|
|
3108
|
+
valid = (f_ppc >= 0) & (f_ppc < n_ppc) & (t_ppc >= 0) & (t_ppc < n_ppc)
|
|
3109
|
+
kept = [
|
|
3110
|
+
position
|
|
3111
|
+
for position, step in enumerate(steps)
|
|
3112
|
+
if step[0] in row_of and valid[row_of[step[0]]]
|
|
3113
|
+
]
|
|
3114
|
+
if len(kept) < len(steps) and not valid.all():
|
|
3115
|
+
self.logger.warning(
|
|
3116
|
+
f"{int((~valid).sum())} lines skipped in the sensitivity computation "
|
|
3117
|
+
"(buses not in the ppc)."
|
|
3118
|
+
)
|
|
3119
|
+
rows = lines.iloc[[row_of[steps[position][0]] for position in kept]]
|
|
3120
|
+
new = np.array([steps[position][1:] for position in kept], dtype=float)
|
|
3121
|
+
new = new.reshape(len(kept), 3)
|
|
3122
|
+
dy = self._line_change_admittance(rows, new)
|
|
3123
|
+
effects = self._voltage_response(rows, dy.real, dy.imag, ctx, buses=buses)
|
|
3124
|
+
effects.columns = kept
|
|
3125
|
+
return effects
|
|
3126
|
+
|
|
3127
|
+
def _line_change_admittance(
|
|
3128
|
+
self, lines: pd.DataFrame, new: np.ndarray
|
|
3129
|
+
) -> np.ndarray:
|
|
3130
|
+
"""
|
|
3131
|
+
Change of the series admittance (p.u.) of each of `lines` when its conductors
|
|
3132
|
+
change to `new` (one row per line: r_ohm_per_km, x_ohm_per_km, parallel count),
|
|
3133
|
+
to first order in the change of its impedance.
|
|
3134
|
+
"""
|
|
3135
|
+
r_pu, x_pu, z_base = self._line_pu_parameters(lines)
|
|
3136
|
+
length = lines["length_km"].to_numpy(dtype=float)
|
|
3137
|
+
r_new = new[:, 0] * length / new[:, 2] / z_base
|
|
3138
|
+
x_new = new[:, 1] * length / new[:, 2] / z_base
|
|
3139
|
+
z_old = r_pu + 1j * x_pu
|
|
3140
|
+
conducts = ~np.isclose(np.abs(z_old) ** 2, 0.0, atol=1e-15)
|
|
3141
|
+
# First order in the impedance change, dy = -y^2 dz: the bus currents barely move
|
|
3142
|
+
# with one line's impedance, so the voltage drop (I z) is close to linear in z.
|
|
3143
|
+
# Linearising in the admittance instead overestimates large steps (about twice the
|
|
3144
|
+
# true effect for one more parallel conductor).
|
|
3145
|
+
y_old = np.zeros_like(z_old)
|
|
3146
|
+
y_old[conducts] = 1.0 / z_old[conducts]
|
|
3147
|
+
return -(y_old**2) * ((r_new - r_pu) + 1j * (x_new - x_pu))
|
|
3148
|
+
|
|
3149
|
+
def get_lines_info(self, line_ids: list[str] | None = None) -> pd.DataFrame:
|
|
3150
|
+
"""
|
|
3151
|
+
Type, length (km), parallel count and impedance per conductor (`r_ohm_per_km`,
|
|
3152
|
+
`x_ohm_per_km`) of lines, indexed by line name (vectorised lookup), with the
|
|
3153
|
+
current (`current_a`, A) the whole line carries in the latest power flow (NaN
|
|
3154
|
+
before one), and the derating factor (`df`, 1 where the table has none), which
|
|
3155
|
+
pandapower multiplies the rating of the line by for its loading.
|
|
3156
|
+
|
|
3157
|
+
The impedance is that of the line table, which a line has whether or not its type
|
|
3158
|
+
is in the standard types.
|
|
3159
|
+
"""
|
|
3160
|
+
lines = self.network.line
|
|
3161
|
+
if line_ids is not None:
|
|
3162
|
+
lines = lines[lines["name"].isin(line_ids)]
|
|
3163
|
+
info = lines[
|
|
3164
|
+
["name", "std_type", "length_km", "r_ohm_per_km", "x_ohm_per_km"]
|
|
3165
|
+
].copy()
|
|
3166
|
+
info["parallel"] = (
|
|
3167
|
+
lines["parallel"].to_numpy() if "parallel" in lines.columns else 1
|
|
3168
|
+
)
|
|
3169
|
+
info["df"] = (
|
|
3170
|
+
lines["df"].fillna(1.0).to_numpy() if "df" in lines.columns else 1.0
|
|
3171
|
+
)
|
|
3172
|
+
info["current_a"] = self.network.res_line["i_ka"].reindex(lines.index) * 1000.0
|
|
3173
|
+
return info.set_index("name")
|
|
3174
|
+
|
|
3175
|
+
def get_line_endpoints(self, line_ids: list[str] | None = None) -> pd.DataFrame:
|
|
3176
|
+
"""
|
|
3177
|
+
Names of the end buses (columns `from_bus`, `to_bus`) of the lines that conduct (in
|
|
3178
|
+
service, no open line switch, between buses in service and supplied), indexed by line name.
|
|
3179
|
+
"""
|
|
3180
|
+
lines = self._select_lines(line_ids)
|
|
3181
|
+
bus_name = self.network.bus["name"]
|
|
3182
|
+
return pd.DataFrame(
|
|
3183
|
+
{
|
|
3184
|
+
"from_bus": bus_name.loc[lines["from_bus"]].to_numpy(),
|
|
3185
|
+
"to_bus": bus_name.loc[lines["to_bus"]].to_numpy(),
|
|
3186
|
+
},
|
|
3187
|
+
index=lines["name"].to_numpy(),
|
|
3188
|
+
)
|
|
3189
|
+
|
|
3190
|
+
def get_closed_bus_switches(self) -> list[tuple[str, str]]:
|
|
3191
|
+
"""
|
|
3192
|
+
Pairs of bus names joined by a closed bus-bus switch (galvanic links that are not lines).
|
|
3193
|
+
"""
|
|
3194
|
+
sw = self.network.switch
|
|
3195
|
+
if sw.empty:
|
|
3196
|
+
return []
|
|
3197
|
+
sw = sw[(sw["et"] == "b") & sw["closed"].astype(bool)]
|
|
3198
|
+
bus_name = self.network.bus["name"]
|
|
3199
|
+
return list(
|
|
3200
|
+
zip(bus_name.loc[sw["bus"]], bus_name.loc[sw["element"]], strict=True)
|
|
3201
|
+
)
|
|
3202
|
+
|
|
3203
|
+
def get_source_buses(self) -> set[str]:
|
|
3204
|
+
"""
|
|
3205
|
+
Names of the buses that feed a galvanic zone: buses of the external grids in service
|
|
3206
|
+
and LV buses of the transformers in service that no open switch disconnects.
|
|
3207
|
+
"""
|
|
3208
|
+
net = self.network
|
|
3209
|
+
buses = set(net.ext_grid.loc[net.ext_grid["in_service"].astype(bool), "bus"])
|
|
3210
|
+
if not net.trafo.empty:
|
|
3211
|
+
feeding = net.trafo["in_service"].astype(bool)
|
|
3212
|
+
switch = net.switch
|
|
3213
|
+
if not switch.empty:
|
|
3214
|
+
opened = switch.loc[
|
|
3215
|
+
(switch["et"] == "t") & ~switch["closed"].astype(bool), "element"
|
|
3216
|
+
]
|
|
3217
|
+
feeding &= ~net.trafo.index.isin(opened)
|
|
3218
|
+
buses |= set(net.trafo.loc[feeding, "lv_bus"])
|
|
3219
|
+
return set(net.bus.loc[sorted(buses), "name"])
|
|
3220
|
+
|
|
3221
|
+
def get_line_ids(self) -> list[str]:
|
|
3222
|
+
"""
|
|
3223
|
+
Names of the lines that conduct: in service, no open line switch, between buses in
|
|
3224
|
+
service and supplied.
|
|
3225
|
+
"""
|
|
3226
|
+
return self._select_lines(None)["name"].tolist()
|
|
3227
|
+
|
|
3228
|
+
def get_line_x_ohm_per_km(self, line_type: str) -> float:
|
|
3229
|
+
"""
|
|
3230
|
+
Get the reactance per unit length for a given line type.
|
|
3231
|
+
"""
|
|
3232
|
+
try:
|
|
3233
|
+
return self.network.std_types["line"][line_type]["x_ohm_per_km"]
|
|
3234
|
+
except KeyError:
|
|
3235
|
+
raise ValueError(f"Line type '{line_type}' not found in standard types")
|
|
3236
|
+
|
|
3237
|
+
def get_flexibility_data(self, element_type: str) -> pd.DataFrame:
|
|
3238
|
+
"""
|
|
3239
|
+
Get flexibility data for loads or sgens.
|
|
3240
|
+
|
|
3241
|
+
Only the elements that carry power are given: those in service, at a bus that a
|
|
3242
|
+
power flow reaches. One that is out of service, at a bus out of service, or at a
|
|
3243
|
+
bus of an island that no source reaches (`_dead_buses`) has no power on the
|
|
3244
|
+
network, so there is nothing to shed or curtail on it, and it is not part of the
|
|
3245
|
+
load or the generation that the shares of a run are taken of. This is read from
|
|
3246
|
+
the topology of the network at each call, with or without a power flow run since.
|
|
3247
|
+
The index is that of the table of the network, whatever is left out.
|
|
3248
|
+
|
|
3249
|
+
The powers are those on the network: pandapower multiplies the `p_mw` and
|
|
3250
|
+
`q_mvar` of a load or a static generator by its `scaling`, and so do the powers
|
|
3251
|
+
given here. `apply_flexibility_action` takes powers on the same footing.
|
|
3252
|
+
|
|
3253
|
+
Args:
|
|
3254
|
+
element_type (str): 'load' or 'sgen'.
|
|
3255
|
+
|
|
3256
|
+
Returns:
|
|
3257
|
+
pd.DataFrame: DataFrame with flexibility data.
|
|
3258
|
+
"""
|
|
3259
|
+
if element_type == "load" and hasattr(self.network, "load"):
|
|
3260
|
+
table = self.network.load
|
|
3261
|
+
df = self._energised(table)[["name", "bus", "p_mw", "q_mvar"]].copy()
|
|
3262
|
+
if "scaling" in table.columns:
|
|
3263
|
+
scaling = table["scaling"].fillna(1.0)
|
|
3264
|
+
df["p_mw"] *= scaling
|
|
3265
|
+
df["q_mvar"] *= scaling
|
|
3266
|
+
flex_settings = self.flexibility_settings.get("load", {})
|
|
3267
|
+
df["bus_name"] = df["bus"].map(self.network.bus["name"])
|
|
3268
|
+
df["max_flex_pct"] = df["name"].map(flex_settings).fillna(0.0)
|
|
3269
|
+
return df
|
|
3270
|
+
elif element_type == "sgen" and hasattr(self.network, "sgen"):
|
|
3271
|
+
table = self.network.sgen
|
|
3272
|
+
df = self._energised(table)[["name", "bus", "p_mw"]].copy()
|
|
3273
|
+
if "scaling" in table.columns:
|
|
3274
|
+
df["p_mw"] *= table["scaling"].fillna(1.0)
|
|
3275
|
+
flex_settings = self.flexibility_settings.get("sgen", {})
|
|
3276
|
+
df["bus_name"] = df["bus"].map(self.network.bus["name"])
|
|
3277
|
+
df["max_flex_pct"] = df["name"].map(flex_settings).fillna(0.0)
|
|
3278
|
+
return df
|
|
3279
|
+
return pd.DataFrame()
|
|
3280
|
+
|
|
3281
|
+
def _energised(self, table: pd.DataFrame) -> pd.DataFrame:
|
|
3282
|
+
"""
|
|
3283
|
+
The rows of a table of elements at a bus (loads, static generators) that are in
|
|
3284
|
+
service and at a bus that is not dead (`_dead_buses`).
|
|
3285
|
+
"""
|
|
3286
|
+
# On the whole columns, and without copying a table that has nothing to leave
|
|
3287
|
+
# out: this is called at each step of a run, on networks that, most of the time,
|
|
3288
|
+
# have no element out of service and no dead bus
|
|
3289
|
+
if "in_service" in table.columns:
|
|
3290
|
+
in_service = table["in_service"].to_numpy()
|
|
3291
|
+
if in_service.dtype != bool:
|
|
3292
|
+
in_service = in_service.astype(bool)
|
|
3293
|
+
if not in_service.all():
|
|
3294
|
+
table = table[in_service]
|
|
3295
|
+
dead = self._dead_buses()
|
|
3296
|
+
if dead and len(table.index) > 0:
|
|
3297
|
+
table = table[~table["bus"].isin(dead)]
|
|
3298
|
+
return table
|
|
3299
|
+
|
|
3300
|
+
def apply_flexibility_action(
|
|
3301
|
+
self,
|
|
3302
|
+
element_type: str,
|
|
3303
|
+
element_index: int,
|
|
3304
|
+
new_p_mw: float,
|
|
3305
|
+
new_q_mvar: float | None = None,
|
|
3306
|
+
) -> None:
|
|
3307
|
+
"""
|
|
3308
|
+
Apply flexibility action.
|
|
3309
|
+
|
|
3310
|
+
The powers are those on the network, as `get_flexibility_data` gives them: the
|
|
3311
|
+
`p_mw` and `q_mvar` written in the table of the network are divided by the
|
|
3312
|
+
`scaling` of the element, by which pandapower multiplies them.
|
|
3313
|
+
|
|
3314
|
+
The method does not check the service state of the element, nor whether its bus
|
|
3315
|
+
is energised: it writes to the element it is given, even when that element is out
|
|
3316
|
+
of service or at a de-energised bus. A caller acting outside `FlexibilityStrategy`,
|
|
3317
|
+
which never selects such an element, must filter them out itself.
|
|
3318
|
+
|
|
3319
|
+
Args:
|
|
3320
|
+
element_type (str): 'load' or 'sgen'.
|
|
3321
|
+
element_index (int): Index of the element.
|
|
3322
|
+
new_p_mw (float): New active power value in MW.
|
|
3323
|
+
new_q_mvar (Optional[float], optional): New reactive power of a load, in MVAr.
|
|
3324
|
+
Defaults to None, which keeps the power factor of the load. That cannot
|
|
3325
|
+
undo a load that was shed down to zero, as the power factor is lost with
|
|
3326
|
+
the active power: restoring such a load needs its reactive power.
|
|
3327
|
+
"""
|
|
3328
|
+
if element_type not in ("load", "sgen"):
|
|
3329
|
+
return
|
|
3330
|
+
table = self.network.load if element_type == "load" else self.network.sgen
|
|
3331
|
+
scaling = 1.0
|
|
3332
|
+
if "scaling" in table.columns:
|
|
3333
|
+
value = table.at[element_index, "scaling"]
|
|
3334
|
+
if pd.notna(value):
|
|
3335
|
+
scaling = float(value)
|
|
3336
|
+
if scaling == 0.0:
|
|
3337
|
+
# An element scaled to nothing has no power on the network to set, and
|
|
3338
|
+
# its table values, which no power on the network gives back, are kept
|
|
3339
|
+
return
|
|
3340
|
+
|
|
3341
|
+
# Simple check to ensure we are not going below 0
|
|
3342
|
+
if new_p_mw < 0:
|
|
3343
|
+
new_p_mw = 0.0
|
|
3344
|
+
original_p = table.at[element_index, "p_mw"]
|
|
3345
|
+
table.at[element_index, "p_mw"] = new_p_mw / scaling
|
|
3346
|
+
|
|
3347
|
+
if element_type == "load":
|
|
3348
|
+
original_q = table.at[element_index, "q_mvar"]
|
|
3349
|
+
if new_q_mvar is None:
|
|
3350
|
+
# Keep the power factor, which a load without active power does not have
|
|
3351
|
+
table.at[element_index, "q_mvar"] = (
|
|
3352
|
+
original_q * (new_p_mw / scaling) / original_p
|
|
3353
|
+
if original_p != 0
|
|
3354
|
+
else original_q
|
|
3355
|
+
)
|
|
3356
|
+
else:
|
|
3357
|
+
table.at[element_index, "q_mvar"] = new_q_mvar / scaling
|
|
3358
|
+
|
|
3359
|
+
label = "Load" if element_type == "load" else "SGen"
|
|
3360
|
+
self.logger.info(
|
|
3361
|
+
f"Modified {label} {element_index}: {original_p * scaling:.5f} MW -> {new_p_mw:.5f} MW"
|
|
3362
|
+
)
|
|
3363
|
+
|
|
3364
|
+
def calculate_voltage_power_sensitivities(
|
|
3365
|
+
self, buses: list[str] | None = None
|
|
3366
|
+
) -> pd.DataFrame:
|
|
3367
|
+
"""
|
|
3368
|
+
Calculate sensitivity of bus voltage magnitudes to active power injection.
|
|
3369
|
+
|
|
3370
|
+
The rows are rows of the inverse of the Jacobian, J^-1. Each is computed from the
|
|
3371
|
+
transposed system J^T y = e, so asking only for the buses that are needed costs
|
|
3372
|
+
one solve per bus instead of the whole inverse.
|
|
3373
|
+
|
|
3374
|
+
Limit, voltage-dependent loads: the sensitivities of the engine, of voltage and
|
|
3375
|
+
of loading alike, are those of loads of constant power. The Jacobian they come
|
|
3376
|
+
from, which the engine builds from pandapower's admittance matrix, holds every
|
|
3377
|
+
load as a constant power: the constant-current and constant-impedance share of
|
|
3378
|
+
a load (``const_i_p_percent``, ``const_i_q_percent``, ``const_z_p_percent``,
|
|
3379
|
+
``const_z_q_percent``) is not in it, so that the sensitivities ignore how such a
|
|
3380
|
+
load follows the voltage. With such a share they are off, by an amount that
|
|
3381
|
+
grows with the share, with the loading of the network and from one metric to
|
|
3382
|
+
another, and they are not corrected. Against central differences of power
|
|
3383
|
+
flows on ``52_MVFeeder1118``, every load at 100 % of the model (median relative
|
|
3384
|
+
errors; ``benchmarks/zip_load_sensitivities.py``, and the table in the
|
|
3385
|
+
methodology documentation): at load x1.0, constant current 2.4 to 3.8 % for
|
|
3386
|
+
the voltage (whole column to buses over 20 % of the largest) and 4.3 % for the
|
|
3387
|
+
loading, constant impedance 4.8 to 7.5 % and 8.5 %; at load x2.5, the factor
|
|
3388
|
+
of the case study, constant current 7.6 to 19 % (at the bus itself to buses
|
|
3389
|
+
over 20 % of the largest) and 21 %, constant impedance 14 to 36 % and 39 %;
|
|
3390
|
+
under 0.01 % with loads of constant power. The feeders of the case study have
|
|
3391
|
+
these columns at 0.
|
|
3392
|
+
|
|
3393
|
+
Args:
|
|
3394
|
+
buses (Optional[List[str]]): Names of the buses whose voltage sensitivities
|
|
3395
|
+
are needed. Defaults to None, for all PQ buses. Names that are not PQ
|
|
3396
|
+
buses of the solution (slack or PV buses, unknown names) are left out.
|
|
3397
|
+
|
|
3398
|
+
Returns:
|
|
3399
|
+
pd.DataFrame: DataFrame with index=bus_names (the requested PQ buses),
|
|
3400
|
+
columns=bus_names (the PV and PQ buses). Values are d|V|_i / dP_j,
|
|
3401
|
+
in pu per MW of active power injected at bus j. Buses joined by a
|
|
3402
|
+
closed bus-bus switch are one bus for the power flow: each of them
|
|
3403
|
+
has the row and the column of that bus.
|
|
3404
|
+
|
|
3405
|
+
Raises:
|
|
3406
|
+
RuntimeError: If there is no converged run of the engine (`run_power_flow`;
|
|
3407
|
+
the results of `pp.runpp` are not used), or if a bus, a line or a
|
|
3408
|
+
transformer has been created or dropped since the last one, whose
|
|
3409
|
+
results are then those of another network.
|
|
3410
|
+
"""
|
|
3411
|
+
net = self.network
|
|
3412
|
+
if not self._has_converged_results():
|
|
3413
|
+
raise RuntimeError(_NO_CONVERGED_RUN)
|
|
3414
|
+
if not self._tables_match_results():
|
|
3415
|
+
raise RuntimeError(_STALE_TABLES)
|
|
3416
|
+
|
|
3417
|
+
if not hasattr(net, "_ppc") or "internal" not in net._ppc:
|
|
3418
|
+
raise RuntimeError("Internal PPC structure not available.")
|
|
3419
|
+
|
|
3420
|
+
ppc_int = net._ppc["internal"]
|
|
3421
|
+
J_sparse = self._converged_jacobian()
|
|
3422
|
+
|
|
3423
|
+
if J_sparse is None:
|
|
3424
|
+
raise ValueError("Jacobian matrix not available.")
|
|
3425
|
+
|
|
3426
|
+
# Jacobian rows (equations): P for (pv, pq), then Q for pq. Columns (variables):
|
|
3427
|
+
# angles for (pv, pq), then magnitudes for pq. d|V|/dP is the block of J^-1 of
|
|
3428
|
+
# the magnitude rows and the P columns.
|
|
3429
|
+
pv = np.asarray(ppc_int["pv"], dtype=int)
|
|
3430
|
+
pq = np.asarray(ppc_int["pq"], dtype=int)
|
|
3431
|
+
n_p_eq = len(pv) + len(pq)
|
|
3432
|
+
|
|
3433
|
+
# Buses fused into one internal bus all get its row and its column
|
|
3434
|
+
rows = self._ppc_bus_names(pq)
|
|
3435
|
+
columns = self._ppc_bus_names(np.concatenate((pv, pq)))
|
|
3436
|
+
if buses is not None:
|
|
3437
|
+
wanted = set(buses)
|
|
3438
|
+
rows = [(position, name) for position, name in rows if name in wanted]
|
|
3439
|
+
solved = np.unique([position for position, _ in rows]).astype(int)
|
|
3440
|
+
solve_of = {position: k for k, position in enumerate(solved)}
|
|
3441
|
+
|
|
3442
|
+
try:
|
|
3443
|
+
lu = self._jacobian_lu(J_sparse)
|
|
3444
|
+
# Row r of J^-1 is y with J^T y = e_r
|
|
3445
|
+
unit = np.zeros((J_sparse.shape[0], len(solved)))
|
|
3446
|
+
unit[n_p_eq + solved, np.arange(len(solved))] = 1.0
|
|
3447
|
+
inverse_rows = lu.solve(unit, trans="T") if len(solved) else unit
|
|
3448
|
+
except Exception as e:
|
|
3449
|
+
self.logger.error(f"Failed to factorise the Jacobian: {e}")
|
|
3450
|
+
return pd.DataFrame()
|
|
3451
|
+
|
|
3452
|
+
# The Jacobian is in per-unit of the network's base power: d|V|/dP_pu, divided
|
|
3453
|
+
# by the base, is in pu per MW
|
|
3454
|
+
values = inverse_rows[:n_p_eq, :].T / float(net.sn_mva)
|
|
3455
|
+
values = values[[solve_of[position] for position, _ in rows], :]
|
|
3456
|
+
return pd.DataFrame(
|
|
3457
|
+
values[:, [position for position, _ in columns]],
|
|
3458
|
+
index=[name for _, name in rows],
|
|
3459
|
+
columns=[name for _, name in columns],
|
|
3460
|
+
)
|
|
3461
|
+
|
|
3462
|
+
def analyze_thermal_violation(
|
|
3463
|
+
self, element_type: str, element_id: str
|
|
3464
|
+
) -> dict[str, Any]:
|
|
3465
|
+
"""
|
|
3466
|
+
Analyze a thermal violation to determine downstream topology and flow conditions.
|
|
3467
|
+
|
|
3468
|
+
Args:
|
|
3469
|
+
element_type (str): "Line" or "Transformer".
|
|
3470
|
+
element_id (str): Name of the element.
|
|
3471
|
+
|
|
3472
|
+
Returns:
|
|
3473
|
+
Dict[str, Any]: Dictionary with analysis results.
|
|
3474
|
+
"""
|
|
3475
|
+
if not self.network:
|
|
3476
|
+
return {}
|
|
3477
|
+
|
|
3478
|
+
try:
|
|
3479
|
+
import networkx as nx
|
|
3480
|
+
import pandapower.topology as ppt
|
|
3481
|
+
except ImportError:
|
|
3482
|
+
self.logger.error(
|
|
3483
|
+
"NetworkX and pandapower.topology are required for thermal analysis."
|
|
3484
|
+
)
|
|
3485
|
+
return {}
|
|
3486
|
+
|
|
3487
|
+
net = self.network
|
|
3488
|
+
|
|
3489
|
+
# Find slack bus (assuming single slack for simplicity)
|
|
3490
|
+
if net.ext_grid.empty:
|
|
3491
|
+
return {}
|
|
3492
|
+
slack_index = net.ext_grid.bus.iloc[0]
|
|
3493
|
+
|
|
3494
|
+
u_elem, v_elem = None, None
|
|
3495
|
+
rated_mva = 0.0
|
|
3496
|
+
p_flow = 0.0
|
|
3497
|
+
upstream = None
|
|
3498
|
+
downstream = None
|
|
3499
|
+
|
|
3500
|
+
# Identify element nodes and rating
|
|
3501
|
+
if element_type == "Line":
|
|
3502
|
+
mask = net.line.name == element_id
|
|
3503
|
+
if not mask.any():
|
|
3504
|
+
return {}
|
|
3505
|
+
idx = net.line[mask].index[0]
|
|
3506
|
+
line = net.line.loc[idx]
|
|
3507
|
+
u_elem, v_elem = line.from_bus, line.to_bus
|
|
3508
|
+
|
|
3509
|
+
# Rated MVA of the line as the engine rates it: the rating of the line
|
|
3510
|
+
# table (not that of its type) of each conductor, times the derating
|
|
3511
|
+
# factor and the parallel conductors
|
|
3512
|
+
derating = line.get("df", 1.0)
|
|
3513
|
+
parallel = line.get("parallel", 1)
|
|
3514
|
+
i_max_ka = (
|
|
3515
|
+
float(line.max_i_ka)
|
|
3516
|
+
* (1.0 if pd.isna(derating) else float(derating))
|
|
3517
|
+
* (1 if pd.isna(parallel) else int(parallel))
|
|
3518
|
+
)
|
|
3519
|
+
|
|
3520
|
+
elif element_type == "Transformer":
|
|
3521
|
+
mask = net.trafo.name == element_id
|
|
3522
|
+
if not mask.any():
|
|
3523
|
+
return {}
|
|
3524
|
+
idx = net.trafo[mask].index[0]
|
|
3525
|
+
trafo = net.trafo.loc[idx]
|
|
3526
|
+
u_elem, v_elem = trafo.hv_bus, trafo.lv_bus
|
|
3527
|
+
# Rated MVA of the transformer as the engine rates it, as for a line: the
|
|
3528
|
+
# rating of each unit, times the derating factor and the units in parallel
|
|
3529
|
+
derating = trafo.get("df", 1.0)
|
|
3530
|
+
parallel = trafo.get("parallel", 1)
|
|
3531
|
+
rated_mva = (
|
|
3532
|
+
float(trafo.sn_mva)
|
|
3533
|
+
* (1.0 if pd.isna(derating) else float(derating))
|
|
3534
|
+
* (1 if pd.isna(parallel) else int(parallel))
|
|
3535
|
+
)
|
|
3536
|
+
else:
|
|
3537
|
+
return {}
|
|
3538
|
+
|
|
3539
|
+
# Topology analysis
|
|
3540
|
+
mg = ppt.create_nxgraph(net, include_trafos=True)
|
|
3541
|
+
|
|
3542
|
+
# Determine Upstream/Downstream based on distance to slack
|
|
3543
|
+
try:
|
|
3544
|
+
dist_u = nx.shortest_path_length(mg, source=slack_index, target=u_elem)
|
|
3545
|
+
except nx.NetworkXNoPath:
|
|
3546
|
+
dist_u = float("inf")
|
|
3547
|
+
|
|
3548
|
+
try:
|
|
3549
|
+
dist_v = nx.shortest_path_length(mg, source=slack_index, target=v_elem)
|
|
3550
|
+
except nx.NetworkXNoPath:
|
|
3551
|
+
dist_v = float("inf")
|
|
3552
|
+
|
|
3553
|
+
if dist_u < dist_v:
|
|
3554
|
+
upstream, downstream = u_elem, v_elem
|
|
3555
|
+
else:
|
|
3556
|
+
upstream, downstream = v_elem, u_elem
|
|
3557
|
+
|
|
3558
|
+
# Calculate Flow and Rating (if line)
|
|
3559
|
+
if element_type == "Line":
|
|
3560
|
+
idx = net.line[mask].index[0]
|
|
3561
|
+
v_kv_base = net.bus.at[upstream, "vn_kv"]
|
|
3562
|
+
rated_mva = np.sqrt(3) * v_kv_base * i_max_ka
|
|
3563
|
+
|
|
3564
|
+
p_flow = (
|
|
3565
|
+
net.res_line.at[idx, "p_from_mw"]
|
|
3566
|
+
if net.line.at[idx, "from_bus"] == upstream
|
|
3567
|
+
else net.res_line.at[idx, "p_to_mw"]
|
|
3568
|
+
)
|
|
3569
|
+
elif element_type == "Transformer":
|
|
3570
|
+
idx = net.trafo[mask].index[0]
|
|
3571
|
+
p_flow = (
|
|
3572
|
+
net.res_trafo.at[idx, "p_hv_mw"]
|
|
3573
|
+
if net.trafo.at[idx, "hv_bus"] == upstream
|
|
3574
|
+
else net.res_trafo.at[idx, "p_lv_mw"]
|
|
3575
|
+
)
|
|
3576
|
+
|
|
3577
|
+
is_flow_towards_downstream = p_flow > 0
|
|
3578
|
+
|
|
3579
|
+
# Identify Downstream Buses
|
|
3580
|
+
if mg.has_edge(u_elem, v_elem):
|
|
3581
|
+
mg.remove_edge(u_elem, v_elem)
|
|
3582
|
+
|
|
3583
|
+
downstream_nodes = (
|
|
3584
|
+
list(nx.node_connected_component(mg, downstream))
|
|
3585
|
+
if downstream in mg
|
|
3586
|
+
else [downstream]
|
|
3587
|
+
)
|
|
3588
|
+
downstream_names = net.bus.loc[
|
|
3589
|
+
net.bus.index.isin(downstream_nodes), "name"
|
|
3590
|
+
].tolist()
|
|
3591
|
+
|
|
3592
|
+
return {
|
|
3593
|
+
"downstream_buses": downstream_names,
|
|
3594
|
+
"flow_mw": p_flow,
|
|
3595
|
+
"rated_mva": rated_mva,
|
|
3596
|
+
"is_flow_towards_downstream": is_flow_towards_downstream,
|
|
3597
|
+
}
|
|
3598
|
+
|
|
3599
|
+
def calculate_branch_loading_sensitivities(
|
|
3600
|
+
self, element_type: str, element_name: str
|
|
3601
|
+
) -> pd.DataFrame:
|
|
3602
|
+
r"""
|
|
3603
|
+
Calculate sensitivity of branch loading to active power injections using Jacobian.
|
|
3604
|
+
|
|
3605
|
+
Returns DataFrame with bus_names as index and one column, ``sensitivity``,
|
|
3606
|
+
containing d(Loading%)/dP_mw for the specific branch, in % per MW of active
|
|
3607
|
+
power injected at the bus.
|
|
3608
|
+
|
|
3609
|
+
The loading differentiated is the one pandapower reports in
|
|
3610
|
+
``res_line.loading_percent`` and ``res_trafo.loading_percent``: it is
|
|
3611
|
+
proportional to the magnitude of the current at the end of the branch where it
|
|
3612
|
+
is the highest (for a transformer, relative to the rated current of each side;
|
|
3613
|
+
to the apparent power of that end with ``trafo_loading="power"``). The current
|
|
3614
|
+
comes from the branch admittances of the solved case, which carry the tap
|
|
3615
|
+
ratio and the phase shift of a transformer and the charging of a line:
|
|
3616
|
+
|
|
3617
|
+
- :math:`I = \sum_k Y_k V_k`, over the two ends :math:`k` of the branch
|
|
3618
|
+
- :math:`\frac{d(\text{Loading}\%)}{d(\theta,V)} = \text{Loading}\%
|
|
3619
|
+
\times \frac{\Re(\bar{I}\, dI/d(\theta,V))}{|I|^2}`
|
|
3620
|
+
- :math:`\frac{d(\text{Loading}\%)}{dP_{bus}} = \frac{d(\text{Loading}\%)}
|
|
3621
|
+
{d(\theta,V)} \frac{d(\theta,V)}{dP_{bus}}`, the last factor being a
|
|
3622
|
+
column of the inverse of the Jacobian. All the buses are obtained from one
|
|
3623
|
+
transposed solve.
|
|
3624
|
+
|
|
3625
|
+
The value is the plain derivative of the loading with respect to the active
|
|
3626
|
+
power injected at the bus, at constant reactive injection: positive means that
|
|
3627
|
+
injecting more at the bus raises the loading of the branch, negative that it
|
|
3628
|
+
lowers it, whatever the direction of the flow in the branch. Shedding a load
|
|
3629
|
+
raises the injection at its bus, curtailing a generator lowers it.
|
|
3630
|
+
|
|
3631
|
+
The voltage-dependent share of the loads (``const_i_*_percent``,
|
|
3632
|
+
``const_z_*_percent``) is not in the Jacobian, and so not in these
|
|
3633
|
+
sensitivities: see the limit in `calculate_voltage_power_sensitivities`.
|
|
3634
|
+
|
|
3635
|
+
Buses joined by a closed bus-bus switch have the same sensitivity. The slack
|
|
3636
|
+
bus, the buses fused with it and the buses out of service have none. The
|
|
3637
|
+
result is empty if there is no converged run of the engine (`run_power_flow`;
|
|
3638
|
+
the results of `pp.runpp` are not used, as in the voltage sensitivities), if
|
|
3639
|
+
the branch is unknown or out of service, or if a bus, a line or a transformer
|
|
3640
|
+
has been created or dropped since the last power flow: the branch could not be
|
|
3641
|
+
found in its results.
|
|
3642
|
+
"""
|
|
3643
|
+
if not self._has_converged_results():
|
|
3644
|
+
return pd.DataFrame()
|
|
3645
|
+
|
|
3646
|
+
net = self.network
|
|
3647
|
+
if not hasattr(net, "_ppc") or "internal" not in net._ppc:
|
|
3648
|
+
return pd.DataFrame()
|
|
3649
|
+
if not self._tables_match_results():
|
|
3650
|
+
self.logger.warning(_STALE_TABLES)
|
|
3651
|
+
return pd.DataFrame()
|
|
3652
|
+
|
|
3653
|
+
ppc_int = net._ppc["internal"]
|
|
3654
|
+
J_sparse = self._converged_jacobian()
|
|
3655
|
+
|
|
3656
|
+
if J_sparse is None:
|
|
3657
|
+
return pd.DataFrame()
|
|
3658
|
+
|
|
3659
|
+
try:
|
|
3660
|
+
lu = self._jacobian_lu(J_sparse)
|
|
3661
|
+
except Exception as e:
|
|
3662
|
+
self.logger.warning(f"Failed to factorize Jacobian: {e}")
|
|
3663
|
+
return pd.DataFrame()
|
|
3664
|
+
|
|
3665
|
+
V_complex = ppc_int.get("V")
|
|
3666
|
+
if V_complex is None:
|
|
3667
|
+
return pd.DataFrame()
|
|
3668
|
+
|
|
3669
|
+
pv = np.asarray(ppc_int["pv"], dtype=int)
|
|
3670
|
+
pq = np.asarray(ppc_int["pq"], dtype=int)
|
|
3671
|
+
n_p_eq = len(pv) + len(pq)
|
|
3672
|
+
|
|
3673
|
+
# The branch in the result tables of pandapower, with the columns that tell
|
|
3674
|
+
# which of its ends sets the loading
|
|
3675
|
+
if element_type == "Line":
|
|
3676
|
+
key, table, results = "line", net.line, net.res_line
|
|
3677
|
+
from_columns, to_columns = ("i_from_ka",), ("i_to_ka",)
|
|
3678
|
+
elif element_type == "Transformer":
|
|
3679
|
+
key, table, results = "trafo", net.trafo, net.res_trafo
|
|
3680
|
+
from_columns = ("i_hv_ka", "p_hv_mw", "q_hv_mvar")
|
|
3681
|
+
to_columns = ("i_lv_ka", "p_lv_mw", "q_lv_mvar")
|
|
3682
|
+
else:
|
|
3683
|
+
return pd.DataFrame()
|
|
3684
|
+
found = np.flatnonzero((table["name"] == element_name).to_numpy())
|
|
3685
|
+
if len(found) == 0 or key not in net._pd2ppc_lookups["branch"]:
|
|
3686
|
+
return pd.DataFrame()
|
|
3687
|
+
position = int(found[0])
|
|
3688
|
+
result = results.iloc[position]
|
|
3689
|
+
loading = float(result["loading_percent"])
|
|
3690
|
+
from_values = [float(result[column]) for column in from_columns]
|
|
3691
|
+
to_values = [float(result[column]) for column in to_columns]
|
|
3692
|
+
|
|
3693
|
+
# Its row in the branch admittances of the solved case, which leaves out the
|
|
3694
|
+
# branches out of service
|
|
3695
|
+
in_service = np.asarray(ppc_int["branch_is"], dtype=bool)
|
|
3696
|
+
branch = net._pd2ppc_lookups["branch"][key][0] + position
|
|
3697
|
+
if not in_service[branch]:
|
|
3698
|
+
return pd.DataFrame()
|
|
3699
|
+
internal_branch = int(np.count_nonzero(in_service[:branch]))
|
|
3700
|
+
|
|
3701
|
+
# The end pandapower takes the loading from, and whether it is its current or
|
|
3702
|
+
# its apparent power
|
|
3703
|
+
by_power = False
|
|
3704
|
+
if element_type == "Line":
|
|
3705
|
+
from_side = from_values[0] >= to_values[0]
|
|
3706
|
+
elif net._options.get("trafo_loading", "current") == "power":
|
|
3707
|
+
by_power = True
|
|
3708
|
+
from_side = np.hypot(*from_values[1:]) >= np.hypot(*to_values[1:])
|
|
3709
|
+
else:
|
|
3710
|
+
trafo = table.iloc[position]
|
|
3711
|
+
from_side = (
|
|
3712
|
+
from_values[0] * trafo["vn_hv_kv"] >= to_values[0] * trafo["vn_lv_kv"]
|
|
3713
|
+
)
|
|
3714
|
+
admittances = ppc_int["Yf" if from_side else "Yt"].tocsr()
|
|
3715
|
+
admittances = admittances.getrow(internal_branch)
|
|
3716
|
+
buses = admittances.indices
|
|
3717
|
+
terms = admittances.data * V_complex[buses] # I = sum(terms)
|
|
3718
|
+
current = terms.sum()
|
|
3719
|
+
|
|
3720
|
+
# Gradient of log(loading) with respect to the state [θ, |V|]: with
|
|
3721
|
+
# V_k = |V_k| exp(jθ_k), dI/dθ_k = j Y_k V_k and dI/d|V_k| = Y_k V_k / |V_k|,
|
|
3722
|
+
# and d log|I| = Re(conj(I) dI) / |I|^2
|
|
3723
|
+
pos_p = np.full(len(V_complex), -1, dtype=int)
|
|
3724
|
+
pos_p[np.concatenate((pv, pq))] = np.arange(n_p_eq)
|
|
3725
|
+
pos_q = np.full(len(V_complex), -1, dtype=int)
|
|
3726
|
+
pos_q[pq] = n_p_eq + np.arange(len(pq))
|
|
3727
|
+
gradient = np.zeros(J_sparse.shape[0])
|
|
3728
|
+
if abs(current) > 0.0 and np.isfinite(loading):
|
|
3729
|
+
relative = np.conj(current) * terms / abs(current) ** 2
|
|
3730
|
+
has_angle, has_magnitude = pos_p[buses] >= 0, pos_q[buses] >= 0
|
|
3731
|
+
np.add.at(gradient, pos_p[buses][has_angle], -relative.imag[has_angle])
|
|
3732
|
+
np.add.at(
|
|
3733
|
+
gradient,
|
|
3734
|
+
pos_q[buses][has_magnitude],
|
|
3735
|
+
(relative.real / np.abs(V_complex[buses]))[has_magnitude],
|
|
3736
|
+
)
|
|
3737
|
+
if by_power:
|
|
3738
|
+
# |S| = |V| |I| at the end of the branch
|
|
3739
|
+
from pandapower.pypower.idx_brch import F_BUS, T_BUS
|
|
3740
|
+
|
|
3741
|
+
end = int(
|
|
3742
|
+
ppc_int["branch"][
|
|
3743
|
+
internal_branch, F_BUS if from_side else T_BUS
|
|
3744
|
+
].real
|
|
3745
|
+
)
|
|
3746
|
+
if pos_q[end] >= 0:
|
|
3747
|
+
gradient[pos_q[end]] += 1.0 / abs(V_complex[end])
|
|
3748
|
+
else:
|
|
3749
|
+
# No current: the loading is at its minimum, where it has no derivative
|
|
3750
|
+
loading = 0.0
|
|
3751
|
+
|
|
3752
|
+
# d(log loading)/dP_bus for every injection bus at once. With c the gradient
|
|
3753
|
+
# with respect to the state, it is c^T J^-1 e_bus, that is the entry of y for
|
|
3754
|
+
# the P equation of the bus, with J^T y = c: one solve instead of one per bus.
|
|
3755
|
+
# The Jacobian is in per-unit of the base power of the network.
|
|
3756
|
+
sensitivity_pct_per_mw = (
|
|
3757
|
+
loading * lu.solve(gradient, trans="T")[:n_p_eq] / float(net.sn_mva)
|
|
3758
|
+
)
|
|
3759
|
+
sensitivities = {
|
|
3760
|
+
name: sensitivity_pct_per_mw[position]
|
|
3761
|
+
for position, name in self._ppc_bus_names(
|
|
3762
|
+
np.concatenate((pv, pq)), missing=None
|
|
3763
|
+
)
|
|
3764
|
+
}
|
|
3765
|
+
|
|
3766
|
+
return pd.DataFrame({"sensitivity": sensitivities})
|