iobroker.luxtronik2-controller 0.25.1 → 1.0.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +8 -13
- package/admin/i18n/uk.json +537 -1
- package/admin/i18n/zh-cn.json +806 -1
- package/io-package.json +27 -27
- package/package.json +1 -1
package/io-package.json
CHANGED
|
@@ -1,8 +1,34 @@
|
|
|
1
1
|
{
|
|
2
2
|
"common": {
|
|
3
3
|
"name": "luxtronik2-controller",
|
|
4
|
-
"version": "0.
|
|
4
|
+
"version": "1.0.0",
|
|
5
5
|
"news": {
|
|
6
|
+
"1.0.0": {
|
|
7
|
+
"en": "*STABLE**",
|
|
8
|
+
"de": "*STABIL**",
|
|
9
|
+
"ru": "*СТАБИЛЬНАЯ**",
|
|
10
|
+
"pt": "*ESTÁVEL**",
|
|
11
|
+
"nl": "*STABIEL**",
|
|
12
|
+
"fr": "*STABLE**",
|
|
13
|
+
"it": "*STABILE*",
|
|
14
|
+
"es": "*ESTABLO**",
|
|
15
|
+
"pl": "*STABILNY**",
|
|
16
|
+
"uk": "*СТАБІЛЬНИЙ**",
|
|
17
|
+
"zh-cn": "*稳定**"
|
|
18
|
+
},
|
|
19
|
+
"0.25.2": {
|
|
20
|
+
"en": "**Fix i18n**",
|
|
21
|
+
"de": "**Fix i18n**",
|
|
22
|
+
"ru": "**Исправление i18n**",
|
|
23
|
+
"pt": "**Fix i18n**",
|
|
24
|
+
"nl": "**i18n** repareren",
|
|
25
|
+
"fr": "**Fix i18n**",
|
|
26
|
+
"it": "*Fix i18n**",
|
|
27
|
+
"es": "**Fix i18n**",
|
|
28
|
+
"pl": "**Napraw i18n**",
|
|
29
|
+
"uk": "**Виправлення i18n**",
|
|
30
|
+
"zh-cn": "**修复 i18n **"
|
|
31
|
+
},
|
|
6
32
|
"0.25.1": {
|
|
7
33
|
"en": "**Removed Dependencies:**\nWS",
|
|
8
34
|
"de": "**Abhängigkeiten entfernt: **\nWS",
|
|
@@ -67,32 +93,6 @@
|
|
|
67
93
|
"pl": "**Poprawka obliczania COP i wydajności („CopManager.ts”) :**\n**Naprawiono astronomiczne wartości COP: ** Rozwiązano krytyczny błąd, w wyniku którego wewnętrzna logika obliczeń przełączała się między licznikami energii określonej i całkowitej, powodując ogromne „delty duchów” i skutkując astronomicznymi wartościami COP (np. > 1000).\n**Przywrócony solidny routing: ** Adapter teraz ściśle i bezpiecznie opiera się na ciągłych licznikach całkowitych („energy_total” i „thermalenergy_total”). Oblicza deltę w przedziale pomiarowym i dynamicznie kieruje ją do wiader ogrzewania lub ciepłej wody w oparciu o stan aktywny.\n_Uwaga:_ Użytkownicy, którzy mają do czynienia z błędem sprzętowym, w wyniku którego pompa ciepła nie śledzi wewnętrznie mocy cieplnej, powinni wybrać „Identyfikator obiektu zewnętrznego” w ustawieniach adaptera i połączyć swój punkt danych `energy_total' jako obejście.",
|
|
68
94
|
"uk": "** Виправлення розрахунку COP та ефективності (`CopManager.ts`) :**\n**Виправлені астрономічні значення COP: ** Вирішено критичну помилку, коли внутрішня логіка обчислень перемикалася між лічильниками конкретної та загальної енергії, викликаючи масивні «дельти привидів» і призводило до астрономічних значень COP (наприклад, > 1000).\n**Відновлена надійна маршрутизація: ** Адаптер тепер суворо та безпечно покладається на безперервні лічильники загального числа (`energy_total` та `thermalenergy_total`). Він обчислює дельту протягом інтервалу опитування та динамічно спрямовує її у відра опалення або гарячої води на основі активного робочого стану.\n_Примітка:_ Користувачі, які стикаються з апаратною помилкою, коли тепловий насос не відстежує потужність ГВП всередині, повинні вибрати «Ідентифікатор зовнішнього об'єкта» в налаштуваннях адаптера та пов'язати свій пункт даних `energy_total` як обхідний шлях.",
|
|
69
95
|
"zh-cn": "**COP 和效率计算修复 (`copManager.ts`):**\n**修复了天文COP值:**解决了内部计算逻辑在特定能量计数器和总能量计数器之间切换的严重错误,这会导致巨大的 “幽灵增量” 并产生天文COP值(例如> 1000)。\n**恢复了稳健路由:** 适配器现在严格而安全地依赖于连续总计数器(“energy_total” 和 “thermalenergy_total”)。它计算轮询间隔内的增量,并根据活动运行状态将其动态路由到供暖或热水桶。\n_注意:_ 面临热泵无法在内部跟踪 DHW 电源的硬件错误的用户应在适配器设置中选择 “外部对象 ID”,并链接他们的 “energy_total” 数据点作为解决方法。"
|
|
70
|
-
},
|
|
71
|
-
"0.23.0": {
|
|
72
|
-
"en": "*🐛 Bugfixes & Tweaks**\n\n**Configuration & Baseline Logic:**\n**Custom Heating Offset Baseline:** Added a new configuration field in the \"Idle Defaults\" tab for the default heating target temperature offset (Parallelverschiebung)[cite: 10].\n**Preserved Baselines:** The idle reset mechanism (`main.ts`) and the PV surplus manager (`pvManager.ts`) now respect this custom baseline (e.g., +1 K) instead of hard-resetting the offset to `0 K`[cite: 7, 13]. This ensures that your manual baseline heating curve is perfectly preserved when returning from a PV boost or entering standby.",
|
|
73
|
-
"de": "* 🐛 Bugfixes & Tweaks**\n\n**Konfiguration und Basislogik: **\n**Benutzerdefinierter Heizkorrekturwert: ** Im Tab „Leerlaufwerte“ wurde ein neues Konfigurationsfeld für die Parallelverschiebung hinzugefügt [Zitat: 10].\n**Beibehaltene Baselines: ** Der Idle-Reset-Mechanismus (`main.ts`) und der PV Surplus Manager (`PVManager.ts`) respektieren jetzt diese Baseline (z. B. +1 K), anstatt den Offset auf `0 K` zu setzen [Zitat: 7, 13]. So bleibt Ihre manuelle Grundheizkurve perfekt erhalten, wenn Sie vom PV-Strom oder in den Standby gehen.",
|
|
74
|
-
"ru": "* 🐛 Исправления ошибок и изменения**\n\n**Конфигурация и базовая логика: **\n**Настраиваемый базовый уровень смещения нагрева: ** На вкладке «Настройки холостого хода» добавлено новое поле конфигурации для смещения целевой температуры нагрева по умолчанию (Parallelverschiebung) [цитата: 10].\n**Сохраненные базовые показатели: ** Механизм перезагрузки в режиме ожидания (`main.ts`) и менеджер избытка фотоэлектрических систем (`PVmanager.ts`) теперь учитывают это настраиваемое базовое значение (например, +1 K) вместо того, чтобы автоматически сбрасывать смещение до «0 K» [цитата: 7, 13]. Это гарантирует, что исходная кривая нагрева, заданная вручную, будет полностью сохранена при возврате из фотоэлектрической станции или переходе в режим ожидания.",
|
|
75
|
-
"pt": "* 🐛 Correções e ajustas**\n\n**Configuração e lógica básica: **\n**Linha de base personalizada de compensação de aquecimento: ** Foi adicionado um novo campo de configuração na guia “Padrões de inatividade” para a meta de aquecimento padrão [cite: 10].\n**Linhas de base preservadas: ** O mecanismo idle reset (`main.ts`) e o gerenciador de excedentes de PV (`PVManager.ts`) agora respeitam essa linha de base personalizada (ex: +1 K) em vez de resetar o offset para `0 K`. Isso garante que sua curva de aquecimento manual seja perfeitamente preservada ao retornar de um aumento fotovoltaico ou de espera.",
|
|
76
|
-
"nl": "* 🐛 Oplossingen en aanpassingen van bug**\n\n**Configuratie en basislogica: **\n**Custom Heating Offset Baseline: ** Een nieuw configuratieveld toegevoegd op het tabblad „Idle Defaults” voor de standaardinstelling van de verwarmingstemperatuur (Parallelverschiebung) [citaat: 10].\n**Bewaarde basislijnen: ** Het inactieve resetmechanisme (`main.ts`) en de PV-surplus manager (`PVManager.ts`) respecteren nu deze aangepaste basislijn (bijv. +1 K) in plaats van de offset hard terug te zetten naar `0 K` [citaat: 7, 13]. Dit zorgt ervoor dat uw handmatige basisverwarmingscurve perfect behouden blijft wanneer u terugkeert van een PV-boost of naar stand-by gaat.",
|
|
77
|
-
"fr": "* 🐛 Corrections et modifications**\n\n**Configuration et logique de base :**\n**Base de calcul personnalisée :** Ajout d'un nouveau champ de configuration dans l'onglet « Idle Defaults » pour le décalage de température cible par défaut (Parallelverschiebung) [cite : 10].\n**Points de référence préservés :** Le mécanisme de réinitialisation au ralenti (`main.ts`) et le gestionnaire de surplus PV (`PVManager.ts`) respectent désormais cette base de référence personnalisée (par exemple, +1 K) au lieu de réinitialiser le décalage à « 0 K » [cite : 7, 13]. Cela garantit que votre courbe de chauffage de base manuelle est parfaitement préservée au retour d'une suralimentation ou en mode veille.",
|
|
78
|
-
"it": "* 🐛 Bugfix e tweak**\n\n**Configurazione e logica di base: **\n**Criteri di base personalizzati: ** Aggiunto un nuovo campo di configurazione nella scheda «Indle Defaults» per l'offset predefinito (Parallelverschiebung) [cite: 10].\n**Baseline preservate: ** Il meccanismo di idle reset (`main.ts`) e il PV surplus manager (`PVManager.ts`) ora rispettano questa baseline personalizzata (ad es. +1 K) invece di resettare l'offset a `0 K`. Ciò garantisce che la curva di riscaldamento di base manuale sia perfetta quando torna da un PV boost o entra in standby.",
|
|
79
|
-
"es": "* 🐛 Correcciones y ajustes**\n\n**Configuración y lógica base: **\n**Base de compensación de calefacción personalizada: ** Se ha añadido un nuevo campo de configuración en la pestaña «Predeterminados de inactividad» para la compensación de temperatura objetivo de calefacción por defecto [cita: 10].\n**Líneas de base conservadas: ** El mecanismo de restablecimiento en vacío (`main.ts`) y el gestor de excedentes fotovoltaicos (`PVManager.ts`) ahora respetan esta base personalizada (por ejemplo, +1 K) en lugar de restablecer el desfase a 0 K [cita: 7, 13]. Esto garantiza que su curva de calentamiento manual de referencia se conserve perfectamente al regresar de un aumento fotovoltaico o al modo de espera.",
|
|
80
|
-
"pl": "* 🐛 Poprawki błędów i poprawki**\n\n**Konfiguracja i logika bazowa: **\n**Niestandardowa linia bazowa przesunięcia ogrzewania: ** Dodano nowe pole konfiguracyjne na karcie „Domyślne ustawienia bezczynności” dla domyślnego docelowego przesunięcia temperatury ogrzewania (równoległe) [cytuj: 10].\n**Zachowane linie bazowe: ** Mechanizm resetowania biegu jałowego („main.ts”) i menedżer nadwyżek fotowoltaicznych („PVManager.ts”) przestrzegają teraz tej niestandardowej linii bazowej (np. +1 K) zamiast trudnego resetowania przesunięcia na „0 K” [cytuj: 7, 13]. Gwarantuje to, że ręczna krzywa ogrzewania bazowego jest doskonale zachowana podczas powrotu z doładowania fotowoltaicznego lub wejścia w tryb gotowości.",
|
|
81
|
-
"uk": "* 🐛 Виправлення помилок та налаштування**\n\n**Логіка конфігурації та базової лінії: **\n**Спеціальна базова лінія зсуву нагріву: ** Додано нове поле конфігурації на вкладці «Типові параметри холостого ходу» для зміщення цільової температури нагріву за замовчуванням (Parallelverschiebung) [цитувати: 10].\n**Збережені базові лінії: ** Механізм скидання простою (`main.ts`) та менеджер надлишків PV (`PVManager.ts`) тепер дотримуються цієї спеціальної базової лінії (наприклад, +1 K) замість жорсткого скидання зміщення до `0 K` [цитувати: 7, 13]. Це гарантує, що ваша ручна базова крива нагріву буде ідеально збережена під час повернення з фотоелектричного підсилення або переходу в режим очікування.",
|
|
82
|
-
"zh-cn": "* 🐛 错误修复和调整**\n\n**配置和基准逻辑:**\n**自定义加热偏移基准:** 在 “空闲默认值” 选项卡中为默认加热目标温度偏移量(Parallelverschiebung)添加了新的配置字段 [引用:10]。\n**保留的基线:** 空闲重置机制(`main.ts`)和光伏剩余管理器(`pvManager.ts`)现在尊重这个自定义基准(例如,+1 K),而不是将偏移量硬重置为`0 K` [引用:7、13]。这可确保在从光伏增压返回或进入待机状态时,您的手动基线加热曲线得到完美保留。"
|
|
83
|
-
},
|
|
84
|
-
"0.22.8": {
|
|
85
|
-
"en": "*🐛 Bugfixes & Tweaks**\n\n**COP & Efficiency Calculation (`copManager.ts`):**\n**Hot Water Hardware Bug Fallback:** Added a dynamic fallback mechanism to bypass a hardware bug present in several Luxtronik and Novelan firmwares where the internal electrical meter for hot water (`energy_warmwater`) permanently reports `0`.\n**Smart Delta Routing:** When the heat pump is actively generating hot water (`WP_BZ_akt === 1`), the COP manager now checks if the internal DHW power meter is stuck at zero. If so, it automatically intercepts the delta from the total energy meter (`energy_total`) over the last polling interval and securely routes it into the Hot Water COP bucket.\n**Continuous Standby Sync:** Enhanced the database tracking to ensure the total energy fallback counter is continuously synced even during standby or heating modes. This prevents idle power consumption from accumulating in the background and falsely distorting the next hot water efficiency calculation.",
|
|
86
|
-
"de": "* 🐛 Bugfixes & Tweaks**\n\n**COP und Effizienzberechnung (`CopManager.TS`) :**\n**Hotwater Hardware Bug Fallback: ** Es wurde ein dynamischer Fallback-Mechanismus hinzugefügt, um einen Hardware-Bug in diversen Luxtronik- und Novelan-Firmwares zu umgehen, bei dem der interne Warmwasserzähler permanent `0` meldet.\n**Smart Delta Routing: ** Wenn die Wärmepumpe aktiv Warmwasser erzeugt (`WP_BZ_AKT === 1`), prüft der COP-Manager nun, ob der interne Warmwasserzähler auf Null steht. Wenn ja, fängt es automatisch das Delta des Gesamtenergiezählers (`energy_total`) im letzten Abfrageintervall ab und leitet es sicher in den Hot Water COP-Bucket.\n**Continuous Standby Sync: ** Das Datenbank-Tracking wurde verbessert, sodass der Gesamtenergieausfallzähler auch im Standby- oder Heizmodus läuft. So wird verhindert, dass sich der Stromverbrauch im Leerlauf ansammelt und die nächste Warmwassereffizienzberechnung verfälscht.",
|
|
87
|
-
"ru": "* 🐛 Исправления ошибок и изменения**\n\n**Расчет КПД и эффективности (`COPmanager.ts`) :**\n**Резервный вариант аппаратного обеспечения горячей воды: ** Добавлен динамический резервный механизм, позволяющий обойти аппаратную ошибку, присутствующую в нескольких прошивках Luxtronik и Novelan, когда внутренний счетчик горячей воды (`energy_warmwater`) постоянно показывает значение «0».\n**Smart Delta Routing: ** Когда тепловой насос активно генерирует горячую воду (`WP_BZ_AKT === 1`), диспетчер COP теперь проверяет, не застрял ли внутренний счетчик мощности ГВС на нуле. В таком случае система автоматически перехватывает значение дельты, полученное на счетчике суммарной энергии (`energy_total`) за последний интервал опроса, и безопасно направляет ее в резервуар COP для горячей воды.\n**Непрерывная синхронизация в режиме ожидания: ** Улучшено отслеживание базы данных, чтобы обеспечить непрерывную синхронизацию счетчика общего запаса энергии даже в режиме ожидания или обогрева. Это предотвращает накопление энергопотребления в режиме ожидания в фоновом режиме и ложное искажение следующего расчета эффективности использования горячей воды.",
|
|
88
|
-
"pt": "* 🐛 Correções e ajustas**\n\n**COP e cálculo de eficiência (`COPManager.ts`) :**\n**Foi adicionado um mecanismo de fallback dinâmico para contornar um bug de hardware presente em vários firmwares Luxtronik e Novelan, em que o medidor elétrico interno de água quente (`energy_warmwater`) informa permanentemente `0`.\n**Smart Delta Routing: ** Quando a bomba de calor gera água quente (`WP_BZ_Akt === 1`), o gerente do COP agora verifica se o medidor interno de DHW está parado em zero. Nesse caso, ele intercepta automaticamente o delta do medidor total (`energy_total`) no último intervalo de pesquisa e o encaminha com segurança para o balde HOT Water COP.\n**Rastreamento do banco de dados aprimorado para garantir a sincronização contínua do contador de energia total mesmo nos modos de espera ou aquecimento. Isso evita que o consumo de energia ociosa se acumule no fundo e distorça o próximo cálculo de eficiência de água quente.",
|
|
89
|
-
"nl": "* 🐛 Oplossingen en aanpassingen van bug**\n\n**COP- en efficiëntieberekening (`COPManager.ts`) :**\n**Fallback van Hot Water Hardware Bug: ** Een dynamisch terugvalmechanisme toegevoegd om een hardwarefout te omzeilen die aanwezig is in verschillende firmwares van Luxtronik en Novelan waarbij de interne elektriciteitsmeter voor warm water (`energy_warmwater`) permanent `0` meldt.\n**Smart Delta Routing: ** Wanneer de warmtepomp actief warm water opwekt (`wp_BZ_Akt === 1`), controleert de COP-manager nu of de interne warmwaterstroommeter op nul staat. Zo ja, dan wordt tijdens de laatste stemperiode automatisch de delta van de totale energiemeter (`energy_total`) onderschept en veilig naar de COP-emmer voor warm water geleid.\n**Continue stand-bysynchronisatie: ** Verbeterde databasetracering om ervoor te zorgen dat de totale terugvalteller voor energie continu wordt gesynchroniseerd, zelfs tijdens de stand-by- of verwarmingsmodus. Dit voorkomt dat het energieverbruik bij stationair gebruik zich ophoopt op de achtergrond, waardoor de volgende berekening van de efficiëntie van warm water ten onrechte wordt verstoord.",
|
|
90
|
-
"fr": "* 🐛 Corrections et modifications**\n\n**COP et calcul de l'efficacité (`COPManager.ts`) :**\n**Hot Water Hardware Bug Fallback :** Ajout d'un mécanisme de secours dynamique pour contourner un bug matériel présent dans plusieurs firmwares Luxtronik et Novelan, où le compteur électrique interne d'eau chaude (« energy_warmwater ») indique « 0 » en permanence.\n**Smart Delta Routing :** Lorsque la pompe à chaleur produit de l'eau chaude (`WP_BZ_AKT === 1`), le COP manager vérifie désormais si le compteur ECS interne est bloqué à zéro. Si c'est le cas, il intercepte automatiquement le delta du compteur d'énergie total (`energy_total`) lors du dernier sondage et l'achemine en toute sécurité vers le seau Hot Water COP.\n**Synchronisation en veille continue :** Le suivi de la base de données a été amélioré pour que le compteur d'énergie soit synchronisé en permanence, même en mode veille ou en mode chauffage. Cela empêche la consommation d'énergie au ralenti de s'accumuler en arrière-plan et de fausser faussement le prochain calcul du rendement de l'eau chaude.",
|
|
91
|
-
"it": "* 🐛 Bugfix e tweak**\n\n**COP e calcolo efficienza (`COPManager.ts`) :**\n**Aggiunto un meccanismo di fallback dinamico per aggirare un bug hardware presente in diversi firmware Luxtronik e Novelan in cui il contatore elettrico interno per l'acqua calda (`energy_warmwater`) riporta permanentemente `0`.\n**Smart Delta Routing: ** Quando la pompa di calore genera acqua calda (`WP_BZ_Akt === 1`), il COP manager ora controlla se il contatore ACS interno è a zero. In tal caso, intercetta automaticamente il delta dal contatore energetico totale (`energy_total`) nell'ultimo intervallo di polling e lo indirizza al bucket COP Hot Water.\n**Sincronizzazione continua in standby: ** È stato migliorato il monitoraggio del database per sincronizzare il contatore totale anche in standby o riscaldamento. Ciò evita che il consumo di energia a vuoto si accumuli in background e distorca erroneamente il successivo calcolo dell'acqua calda.",
|
|
92
|
-
"es": "* 🐛 Correcciones y ajustes**\n\n**Cálculo de COP y eficiencia (`CopManager.ts`) :**\n**Solución de errores de hardware: ** Se ha añadido un mecanismo de respaldo dinámico para evitar un error de hardware presente en varios firmwares de Luxtronik y Novelan, por el que el contador eléctrico interno de agua caliente (`energy_warmwater`) informa permanentemente de un 0.\n**Enrutamiento Delta inteligente: ** Cuando la bomba de calor genera agua caliente (`WP_BZ_akt === 1`), el gestor de COP comprueba ahora si el contador de ACS interno está en cero. Si es así, intercepta automáticamente el delta del contador de energía total (`energy_total`) en el último intervalo de sondeo y lo dirige de forma segura a la cubeta COP de Hot Water.\n**Sincronización continua en espera: ** Se ha mejorado el seguimiento de la base de datos para garantizar que el contador de energía total se sincronice continuamente, incluso en modo de espera o calefacción. Esto evita que el consumo de energía en reposo se acumule en segundo plano y distorsione falsamente el próximo cálculo de eficiencia del agua caliente.",
|
|
93
|
-
"pl": "* 🐛 Poprawki błędów i poprawki**\n\n**COP i obliczanie wydajności („CopManager.ts”) :**\n**Błąd sprzętu gorącej wody: ** Dodano dynamiczny mechanizm awaryjny, aby ominąć błąd sprzętowy występujący w kilku firmwareach Luxtronik i Novelan, w których wewnętrzny licznik elektryczny ciepłej wody („energy_warmwater”) na stałe zgłasza `0`.\n**Smart Delta Routing: ** Gdy pompa ciepła aktywnie wytwarza ciepłą wodę (`WP_BZ_Akt === 1`), kierownik COP sprawdza teraz, czy wewnętrzny miernik mocy cieplnej utknął na zerowym poziomie. Jeśli tak, automatycznie przechwytuje deltę z licznika energii całkowitej („energy_total”) w ostatnim przedziale sondażu i bezpiecznie kieruje ją do wiadra COP ciepłej wody.\n**Ciągła synchronizacja czuwania: ** Ulepszono śledzenie bazy danych, aby zapewnić ciągłą synchronizację licznika rezerwowego całkowitej energii nawet w trybie czuwania lub ogrzewania. Zapobiega to gromadzeniu się zużycia energii na biegu jałowym w tle i fałszywym zniekształceniu następnego obliczenia efektywności ciepłej wody.",
|
|
94
|
-
"uk": "* 🐛 Виправлення помилок та налаштування**\n\n**Розрахунок COP та ефективності (`CopManager.ts`) :**\n**Запасна помилка гарячої води: ** Додано динамічний резервний механізм для обходу апаратної помилки, присутньої в декількох прошивках Luxtronik та Novelan, де внутрішній електричний лічильник гарячої води (`energy_warmwater`) постійно повідомляє `0`.\n**Розумна дельта-маршрутизація: ** Коли тепловий насос активно генерує гарячу воду (`WP_BZ_Akt === 1`), менеджер COP тепер перевіряє, чи застряг внутрішній лічильник потужності ГВП на нулі. Якщо так, він автоматично перехоплює дельту з лічильника загальної енергії (`energy_total`) протягом останнього інтервалу опитування та надійно направляє її у відро COP гарячої води.\n**Безперервна синхронізація в режимі очікування: ** Покращено відстеження бази даних, щоб гарантувати постійну синхронізацію лічильника загальної запасної енергії навіть у режимі очікування або нагрівання. Це запобігає накопиченню споживання енергії на холостому режимі у фоновому режимі та помилковому спотворенню наступного розрахунку ефективності гарячої води.",
|
|
95
|
-
"zh-cn": "* 🐛 错误修复和调整**\n\n**COP 和效率计算 (`copManager.ts`): **\n**热水硬件错误备份:**添加了动态备用机制,以绕过几款Luxtronik和Novelan固件中存在的硬件错误,在该错误中,内部热水电表(“energy_warmwater”)永久报告为 “0”。\n**智能三角路由:** 当热泵主动产生热水(`wp_bz_AKT === 1`)时,COP 管理器现在会检查内部 DHW 功率计是否停留在零。如果是,它会在最后一个轮询间隔内自动拦截总能量计(“energy_total”)中的增量,并将其安全地路由到热水 COP 存储桶中。\n**持续待机同步:** 增强了数据库跟踪,确保即使在待机或加热模式下,总能量回退计数器也能持续同步。这样可以防止空闲功耗在后台累积,从而错误地扭曲下一次的热水效率计算。"
|
|
96
96
|
}
|
|
97
97
|
},
|
|
98
98
|