iobroker.luxtronik2-controller 0.25.1 → 1.0.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/README.md CHANGED
@@ -102,6 +102,14 @@ You might see red error messages in the installation log related to `node-gyp`,
102
102
  //### **WORK IN PROGRESS**
103
103
 
104
104
  ## Changelog
105
+ ### 1.0.0 (2026-11-16)
106
+
107
+ **STABLE**
108
+
109
+ ### 0.25.2 (2026-11-16)
110
+
111
+ - **Fix i18n**
112
+
105
113
  ### 0.25.1 (2026-11-16)
106
114
 
107
115
  - **Removed Dependencies:**
@@ -133,19 +141,6 @@ You might see red error messages in the installation log related to `node-gyp`,
133
141
  - **Strict Backend Write Lock:** Enforced a global hardware write lock in Read-Only mode across `onReady`, `syncConfigValue`, `runOptimizationSchedule`, and `onStateChange` (while keeping diagnostic functions like debug logging, raw dumps, and firmware checks active).
134
142
  - **Automatic Config Migration:** Existing installations are seamlessly migrated on startup to the matching operating mode based on their previously active Modbus and optimization settings.
135
143
 
136
- ### 0.23.2 (2026-11-07)
137
-
138
- - **COP & Efficiency Calculation (`copManager.ts`):**
139
- - **Isolated Counter Tracking:** Introduced dedicated reference states for Total, Heating, and Hot Water counters (`last_raw_power_*` and `last_raw_thermal_*`). Each counter is now compared strictly against its own previous value, completely preventing cross-mode "ghost deltas" and astronomical COP spikes during cycle transitions.
140
- - **Automatic Total-Delta Fallback:** Added seamless fallback detection for controllers with firmware bugs (e.g., Novelan LAV) where mode-specific counters like `energy_warmwater` remain permanently at `0`. If a specific counter reports a delta of `0` during an active cycle, the adapter automatically uses the live delta of the corresponding total counter (`energy_total` / `thermalenergy_total`) without requiring manual configuration workarounds.
141
-
142
- ### 0.23.1 (2026-11-07)
143
-
144
- - **COP & Efficiency Calculation Fix (`copManager.ts`):**
145
- - **Fixed Astronomical COP Values:** Resolved a critical bug where the internal calculation logic switched between specific and total energy counters, causing massive "ghost deltas" and resulting in astronomical COP values (e.g., > 1000).
146
- - **Restored Robust Routing:** The adapter now strictly and safely relies on the continuous total counters (`energy_total` and `thermalenergy_total`). It calculates the delta over the polling interval and dynamically routes it into the Heating or Hot Water buckets based on the active operating state.
147
- - _Note:_ Users facing the hardware bug where the heat pump does not track DHW power internally should select "External Object ID" in the adapter settings and link their `energy_total` datapoint as a workaround.
148
-
149
144
  ## License
150
145
 
151
146
  MIT License