@zwave-js/config 11.4.0 → 11.4.2

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (75) hide show
  1. package/build/devices/CompatConfig.d.ts +32 -1
  2. package/build/devices/CompatConfig.d.ts.map +1 -1
  3. package/build/devices/CompatConfig.js +114 -17
  4. package/build/devices/CompatConfig.js.map +1 -1
  5. package/build/utils_safe.d.ts +2 -0
  6. package/build/utils_safe.d.ts.map +1 -1
  7. package/build/utils_safe.js +21 -1
  8. package/build/utils_safe.js.map +1 -1
  9. package/config/devices/0x0005/pe653.json +453 -34
  10. package/config/devices/0x000c/hs-fls100.json +1 -1
  11. package/config/devices/0x000c/hs-wd100.json +1 -1
  12. package/config/devices/0x000c/hs-wd200.json +1 -1
  13. package/config/devices/0x0039/39358_39465_zw4002.json +1 -1
  14. package/config/devices/0x003b/be469zp.json +1 -1
  15. package/config/devices/0x0060/ac301.json +1 -1
  16. package/config/devices/0x0060/hac01.json +1 -1
  17. package/config/devices/0x0060/sp816.json +1 -1
  18. package/config/devices/0x0063/10974_zw4002.json +1 -1
  19. package/config/devices/0x0063/12730_zw4002.json +1 -1
  20. package/config/devices/0x0063/14287_zw4002.json +1 -1
  21. package/config/devices/0x0063/14314_zw4002.json +1 -1
  22. package/config/devices/0x0063/14318_zw4005.json +1 -1
  23. package/config/devices/0x0063/45743_zw4002.json +1 -1
  24. package/config/devices/0x0063/55258_zw4002.json +1 -1
  25. package/config/devices/0x0063/55259_zw4002.json +1 -1
  26. package/config/devices/0x0086/dsa03202.json +1 -1
  27. package/config/devices/0x0109/zd2102-5.json +1 -1
  28. package/config/devices/0x010f/fgbs001.json +1 -1
  29. package/config/devices/0x010f/fgt001.json +1 -1
  30. package/config/devices/0x0115/zme_ft.json +38 -15
  31. package/config/devices/0x0118/tz69.json +1 -1
  32. package/config/devices/0x011a/zwn-rsm2.json +1 -1
  33. package/config/devices/0x0129/yale_smart_door_lock_z-wave_module.json +21 -2
  34. package/config/devices/0x0131/rgbwe2.json +16 -1
  35. package/config/devices/0x0152/gr-b3-3.json +1 -1
  36. package/config/devices/0x0154/pope700168.json +1 -1
  37. package/config/devices/0x0157/ev100.json +1 -1
  38. package/config/devices/0x0159/zmnhaa.json +2 -2
  39. package/config/devices/0x0159/zmnhda.json +2 -2
  40. package/config/devices/0x015f/mh-c221.json +1 -1
  41. package/config/devices/0x015f/mh-c421.json +1 -1
  42. package/config/devices/0x015f/{mh-s220.json → mh-s220_0.0-3.1.json} +1 -1
  43. package/config/devices/0x015f/mh-s220_3.2.json +270 -0
  44. package/config/devices/0x017c/heatapp_floor.json +17 -5
  45. package/config/devices/0x0184/wd-100.json +1 -1
  46. package/config/devices/0x018c/pm-140-zw.json +1 -1
  47. package/config/devices/0x018c/pm-240-zw.json +1 -1
  48. package/config/devices/0x018c/pm-340-zw.json +1 -1
  49. package/config/devices/0x019b/4512689.json +1 -1
  50. package/config/devices/0x019b/heatit_z-relay.json +1 -1
  51. package/config/devices/0x019b/z-han2.json +176 -0
  52. package/config/devices/0x019b/z-trm3.json +1 -1
  53. package/config/devices/0x019b/zm_dimmer.json +262 -0
  54. package/config/devices/0x0267/10002034-13x.json +4 -0
  55. package/config/devices/0x0267/1000x080-xxx-700.json +1 -1
  56. package/config/devices/0x027a/zse19.json +1 -1
  57. package/config/devices/0x027a/zse29.json +1 -1
  58. package/config/devices/0x0287/iblindsv3.json +1 -1
  59. package/config/devices/0x0312/mp21z.json +1 -1
  60. package/config/devices/0x0315/wd-100.json +1 -1
  61. package/config/devices/0x0315/zl-pd-100.json +1 -1
  62. package/config/devices/0x031e/lzw36.json +1 -1
  63. package/config/devices/0x0330/sr-zv9032a-eu.json +390 -0
  64. package/config/devices/0x0344/he-ft01.json +1 -1
  65. package/config/devices/0x0344/he-ht01.json +1 -1
  66. package/config/devices/0x0344/he-tps01.json +1 -1
  67. package/config/devices/0x0344/he-tps02.json +1 -1
  68. package/config/devices/0x0344/he-tps03.json +1 -1
  69. package/config/devices/0x0344/he-tps04.json +1 -1
  70. package/config/devices/0x0344/he-tps05.json +1 -1
  71. package/config/devices/0x0371/zwa018.json +4 -0
  72. package/config/devices/0x0438/sr-zv9032a-eu.json +1 -0
  73. package/config/devices/0x045a/Z-CM-V01.json +4 -7
  74. package/config/devices/0x5254/zxt-800.json +254 -0
  75. package/package.json +1 -1
@@ -40,7 +40,7 @@
40
40
  "treatBasicSetAsEvent": true,
41
41
  "commandClasses": {
42
42
  "remove": {
43
- "0x6c": {
43
+ "Supervision": {
44
44
  // The device does not support supervision although it is mandatory for the device type
45
45
  "endpoints": "*"
46
46
  }
@@ -86,7 +86,7 @@
86
86
  "compat": {
87
87
  "commandClasses": {
88
88
  "add": {
89
- "0x84": {
89
+ "Wake Up": {
90
90
  // To fix issue #1536
91
91
  "isSupported": true,
92
92
  "version": 1
@@ -43,7 +43,7 @@
43
43
  "compat": {
44
44
  "commandClasses": {
45
45
  "add": {
46
- "0x20": {
46
+ "Basic": {
47
47
  // This device should send Notification Reports, but they seem to get lost often
48
48
  // Basic Set comes through
49
49
  "isSupported": true
@@ -321,7 +321,7 @@
321
321
  "remove": {
322
322
  // Alarm Sensor CC is reported as supported, but we either get no response
323
323
  // or the supported sensor types are incorrectly encoded
324
- "0x9c": {
324
+ "Alarm Sensor": {
325
325
  "endpoints": "*"
326
326
  }
327
327
  }
@@ -144,7 +144,7 @@
144
144
  // Hide CCs from root endpoint that are duplicated on the manually preserved endpoint 1
145
145
  "commandClasses": {
146
146
  "remove": {
147
- "0x80": {
147
+ "Battery": {
148
148
  "endpoints": [0]
149
149
  }
150
150
  }
@@ -15,16 +15,15 @@
15
15
  },
16
16
  "associations": {
17
17
  "1": {
18
- "label": "Group 1",
19
- "description": "Unsolicited notifications about thermostat mode and setpoint temperature changes",
18
+ "label": "Lifeline",
20
19
  "maxNodes": 10
21
20
  }
22
21
  },
23
22
  "paramInformation": [
24
23
  {
25
24
  "#": "1",
26
- "label": "Boost Dry mode duration",
27
- "unit": "sec",
25
+ "label": "Boost Dry Mode Duration",
26
+ "unit": "seconds",
28
27
  "valueSize": 2,
29
28
  "minValue": 0,
30
29
  "maxValue": 1800,
@@ -32,7 +31,7 @@
32
31
  },
33
32
  {
34
33
  "#": "2",
35
- "label": "Button mode",
34
+ "label": "Button Mode",
36
35
  "valueSize": 1,
37
36
  "defaultValue": 0,
38
37
  "allowManualEntry": false,
@@ -53,7 +52,7 @@
53
52
  },
54
53
  {
55
54
  "#": "3",
56
- "label": "Basic mode",
55
+ "label": "Basic Mode",
57
56
  "valueSize": 1,
58
57
  "defaultValue": 0,
59
58
  "allowManualEntry": false,
@@ -82,7 +81,7 @@
82
81
  },
83
82
  {
84
83
  "#": "4",
85
- "label": "Temperature control interval",
84
+ "label": "Temperature Control Interval",
86
85
  "unit": "sec",
87
86
  "valueSize": 1,
88
87
  "minValue": 1,
@@ -91,8 +90,8 @@
91
90
  },
92
91
  {
93
92
  "#": "5",
94
- "label": "Maximum allowed temperature deviation",
95
- "unit": "in 0.1 C",
93
+ "label": "Maximum Temperature Deviation",
94
+ "unit": "0.1 °C",
96
95
  "valueSize": 1,
97
96
  "minValue": 1,
98
97
  "maxValue": 60,
@@ -100,8 +99,8 @@
100
99
  },
101
100
  {
102
101
  "#": "6",
103
- "label": "Maximal allowed temperature",
104
- "unit": "degree Celsus",
102
+ "label": "Maximum Temperature",
103
+ "unit": "°C",
105
104
  "valueSize": 1,
106
105
  "minValue": 20,
107
106
  "maxValue": 55,
@@ -109,13 +108,37 @@
109
108
  },
110
109
  {
111
110
  "#": "10",
112
- "label": "Typical click timeout",
113
- "description": "Typical time used to differentiate click from hold",
114
- "unit": "in 10ms",
111
+ "label": "Typical Click Timeout",
112
+ "description": "Used to differentiate click from hold",
113
+ "unit": "10 ms",
115
114
  "valueSize": 1,
116
115
  "minValue": 1,
117
116
  "maxValue": 100,
118
117
  "defaultValue": 50
119
118
  }
120
- ]
119
+ ],
120
+ "compat": {
121
+ "overrideQueries": {
122
+ // The device does not report Off as a supported thermostat mode
123
+ "Thermostat Mode": [
124
+ {
125
+ "method": "getSupportedModes",
126
+ "result": [0, 1, 7, 11], // Off / Heat / Furnace / Energy Heat
127
+ "persistValues": {
128
+ "supportedModes": [0, 1, 7, 11]
129
+ },
130
+ "extendMetadata": {
131
+ "thermostatMode": {
132
+ "states": {
133
+ "Off": 0,
134
+ "Heat": 1,
135
+ "Furnace": 7,
136
+ "Energy heat": 11
137
+ }
138
+ }
139
+ }
140
+ }
141
+ ]
142
+ }
143
+ }
121
144
  }
@@ -110,7 +110,7 @@
110
110
  "commandClasses": {
111
111
  "add": {
112
112
  // This device is a binary switch, but claims not to support the Binary Switch CC
113
- "0x25": {
113
+ "Binary Switch": {
114
114
  "isSupported": true
115
115
  }
116
116
  }
@@ -66,7 +66,7 @@
66
66
  "add": {
67
67
  // The device needs a multi channel lifeline association (target endpoint 0),
68
68
  // but only reports support for V2, which doesn't allow this.
69
- "0x8e": {
69
+ "Multi Channel Association": {
70
70
  "version": 3
71
71
  }
72
72
  }
@@ -69,13 +69,32 @@
69
69
  "remove": {
70
70
  // At least in FW 33.16 the lock always responds with Supervision session ID 0,
71
71
  // which means Z-Wave JS cannot map the response to the request
72
- "0x6c": {
72
+ "Supervision": {
73
73
  "endpoints": "*"
74
74
  }
75
75
  }
76
76
  },
77
77
  // The lock is sometimes a bit slow to respond
78
- "reportTimeout": 5000
78
+ "reportTimeout": 5000,
79
+ // The lock claims to have 20 schedule slots per user,
80
+ // but it has 20 users with 1 schedule slot each
81
+ "overrideQueries": {
82
+ "Schedule Entry Lock": [
83
+ {
84
+ "method": "getNumSlots",
85
+ "result": {
86
+ "numWeekDaySlots": 0,
87
+ "numYearDaySlots": 0,
88
+ "numDailyRepeatingSlots": 1
89
+ },
90
+ "persistValues": {
91
+ "numWeekDaySlots": 0,
92
+ "numYearDaySlots": 0,
93
+ "numDailyRepeatingSlots": 1
94
+ }
95
+ }
96
+ ]
97
+ }
79
98
  },
80
99
  "metadata": {
81
100
  "inclusion": "Put the Z-Wave controller into add mode\n\nEnter the Master code on the lock, followed by #\n\nPress the 4 button, followed by #\n\nPress the 1 button followed by #\n\nRefer to the operation manual of the Z-Wave controller to complete the add/inclusion process\n\nFor more information on this please visit:\nwww.yale.co.uk/smart-living",
@@ -77,5 +77,20 @@
77
77
  }
78
78
  ]
79
79
  }
80
- ]
80
+ ],
81
+ "compat": {
82
+ "overrideQueries": {
83
+ "Color Switch": [
84
+ // The device supports 5 color channels (Warm/Cold white, RGB)
85
+ // but does not advertise support for blue
86
+ {
87
+ "method": "getSupported",
88
+ "result": [0, 1, 2, 3, 4],
89
+ "persistValues": {
90
+ "supportedColorComponents": [0, 1, 2, 3, 4]
91
+ }
92
+ }
93
+ ]
94
+ }
95
+ }
81
96
  }
@@ -34,7 +34,7 @@
34
34
  "compat": {
35
35
  "commandClasses": {
36
36
  "add": {
37
- "0x60": {
37
+ "Multi Channel": {
38
38
  // This device has 3 channels, but it responds to the CC version request with 0
39
39
  "isSupported": true,
40
40
  "version": 2
@@ -102,7 +102,7 @@
102
102
  // The device uses Basic Set commands to report rain.
103
103
  // We don't set up an association in group 2 or 3 by default, but if a user does,
104
104
  // this is needed or the Basic CC will be hidden
105
- "0x20": {
105
+ "Basic": {
106
106
  "isSupported": true
107
107
  }
108
108
  }
@@ -18,7 +18,7 @@
18
18
  // The device supports Battery CC, despite the Version query telling otherwise
19
19
  "commandClasses": {
20
20
  "add": {
21
- "0x80": {
21
+ "Battery": {
22
22
  "isSupported": true,
23
23
  "version": 1
24
24
  }
@@ -148,12 +148,12 @@
148
148
  "compat": {
149
149
  "commandClasses": {
150
150
  "add": {
151
- "0x72": {
151
+ "Manufacturer Specific": {
152
152
  // Manufacturer Specific CC is supported, but comes back as version 0
153
153
  "version": 1,
154
154
  "isSupported": true
155
155
  },
156
- "0x85": {
156
+ "Association": {
157
157
  // Association CC is supported, but comes back as version 0
158
158
  "version": 1,
159
159
  "isSupported": true
@@ -174,8 +174,8 @@
174
174
  "compat": {
175
175
  "commandClasses": {
176
176
  "add": {
177
- // The device lists Binary Switch CC as supported, but then responds with a version of 0
178
- "0x85": {
177
+ // The device lists Association CC as supported, but then responds with a version of 0
178
+ "Association": {
179
179
  "isSupported": true
180
180
  }
181
181
  }
@@ -40,7 +40,7 @@
40
40
  "compat": {
41
41
  "commandClasses": {
42
42
  "add": {
43
- "0x26": {
43
+ "Multilevel Switch": {
44
44
  // This is a roller shutter, but it responds to the CC version request with 0
45
45
  "isSupported": true,
46
46
  "version": 1
@@ -204,7 +204,7 @@
204
204
  "compat": {
205
205
  "commandClasses": {
206
206
  "add": {
207
- "0x26": {
207
+ "Multilevel Switch": {
208
208
  // This is a roller shutter, but it responds to the CC version request with 0
209
209
  "isSupported": true,
210
210
  "version": 1
@@ -15,7 +15,7 @@
15
15
  ],
16
16
  "firmwareVersion": {
17
17
  "min": "0.0",
18
- "max": "255.255"
18
+ "max": "3.1"
19
19
  },
20
20
  "associations": {
21
21
  "1": {
@@ -0,0 +1,270 @@
1
+ {
2
+ "manufacturer": "McoHome Technology Co., Ltd.",
3
+ "manufacturerId": "0x015f",
4
+ "label": "MH-S220",
5
+ "description": "Micro Switch",
6
+ "devices": [
7
+ {
8
+ "productType": "0x2201",
9
+ "productId": "0x1252"
10
+ },
11
+ {
12
+ "productType": "0x2201",
13
+ "productId": "0x7202"
14
+ }
15
+ ],
16
+ "firmwareVersion": {
17
+ "min": "3.2",
18
+ "max": "255.255"
19
+ },
20
+ "associations": {
21
+ "1": {
22
+ "label": "Lifeline",
23
+ "maxNodes": 1,
24
+ "isLifeline": true
25
+ },
26
+ "2": {
27
+ "label": "Switch 1",
28
+ "maxNodes": 5
29
+ },
30
+ "3": {
31
+ "label": "Switch 2",
32
+ "maxNodes": 5
33
+ }
34
+ },
35
+ "paramInformation": [
36
+ {
37
+ "#": "1",
38
+ "$import": "~/templates/master_template.json#state_after_power_failure_off_prev"
39
+ },
40
+ {
41
+ "#": "2",
42
+ "label": "External Switch Type",
43
+ "valueSize": 1,
44
+ "defaultValue": 1,
45
+ "allowManualEntry": false,
46
+ "options": [
47
+ {
48
+ "label": "Momentary buttons",
49
+ "value": 0
50
+ },
51
+ {
52
+ "label": "Toggle switches",
53
+ "value": 1
54
+ }
55
+ ]
56
+ },
57
+ {
58
+ "#": "3",
59
+ "label": "Toggle Switch Behavior",
60
+ "valueSize": 1,
61
+ "defaultValue": 1,
62
+ "allowManualEntry": false,
63
+ "options": [
64
+ {
65
+ "label": "Without specified on/off position",
66
+ "value": 0
67
+ },
68
+ {
69
+ "label": "With specified on/off position",
70
+ "value": 1
71
+ }
72
+ ]
73
+ },
74
+ {
75
+ "#": "5",
76
+ "label": "Auto-Off Timer",
77
+ "valueSize": 2,
78
+ "minValue": 0,
79
+ "maxValue": 65535,
80
+ "defaultValue": 0,
81
+ "unit": "seconds",
82
+ "unsigned": true,
83
+ "options": [
84
+ {
85
+ "label": "Disabled",
86
+ "value": 0
87
+ }
88
+ ]
89
+ },
90
+ {
91
+ "#": "4",
92
+ "$import": "~/templates/master_template.json#base_enable_disable",
93
+ "label": "Auto-Off Timer: Manual Operation",
94
+ "description": "Allow manually turning off the device when the auto-off timer is active",
95
+ "defaultValue": 1
96
+ },
97
+ {
98
+ "#": "6",
99
+ "label": "All On / All Off",
100
+ "valueSize": 1,
101
+ "defaultValue": 0,
102
+ "allowManualEntry": false,
103
+ "unsigned": true,
104
+ "options": [
105
+ {
106
+ "label": "Do not allow all-on and all-off",
107
+ "value": 0
108
+ },
109
+ {
110
+ "label": "Do not allow all-on / Allow all-off",
111
+ "value": 1
112
+ },
113
+ {
114
+ "label": "Allow all-on / Do not allow all-off",
115
+ "value": 2
116
+ },
117
+ {
118
+ "label": "Allow all-on and all-off",
119
+ "value": 255
120
+ }
121
+ ]
122
+ },
123
+ {
124
+ "#": "8",
125
+ "label": "Switch 1: Report to Association Group 2",
126
+ "valueSize": 1,
127
+ "defaultValue": 0,
128
+ "allowManualEntry": false,
129
+ "unsigned": true,
130
+ "options": [
131
+ {
132
+ "label": "Report both on/off",
133
+ "value": 0
134
+ },
135
+ {
136
+ "label": "Report on only",
137
+ "value": 1
138
+ },
139
+ {
140
+ "label": "Report off only",
141
+ "value": 2
142
+ },
143
+ {
144
+ "label": "Report disabled",
145
+ "value": 255
146
+ }
147
+ ]
148
+ },
149
+ {
150
+ "#": "9",
151
+ "label": "Switch 2: Report Type",
152
+ "description": "Scene Activation will be sent to the controller, Basic Set to group 3.",
153
+ "valueSize": 1,
154
+ "defaultValue": 1,
155
+ "allowManualEntry": false,
156
+ "unsigned": true,
157
+ "options": [
158
+ {
159
+ "label": "Scene Activation and Basic Set",
160
+ "value": 0
161
+ },
162
+ {
163
+ "label": "Scene Activation",
164
+ "value": 1
165
+ },
166
+ {
167
+ "label": "Basic Set",
168
+ "value": 2
169
+ },
170
+ {
171
+ "label": "Disable",
172
+ "value": 255
173
+ }
174
+ ]
175
+ },
176
+ {
177
+ "#": "10",
178
+ "label": "Switch 2: Report to Association Group 3",
179
+ "valueSize": 1,
180
+ "defaultValue": 1,
181
+ "allowManualEntry": false,
182
+ "unsigned": true,
183
+ "options": [
184
+ {
185
+ "label": "Report both on/off",
186
+ "value": 0
187
+ },
188
+ {
189
+ "label": "Report on only",
190
+ "value": 1
191
+ },
192
+ {
193
+ "label": "Report off only",
194
+ "value": 2
195
+ },
196
+ {
197
+ "label": "Disable",
198
+ "value": 255
199
+ }
200
+ ]
201
+ },
202
+ {
203
+ "#": "11",
204
+ "label": "Switch S2: Scene ID (Single Click)",
205
+ "description": "Will be sent to the controller.",
206
+ "valueSize": 1,
207
+ "minValue": 0,
208
+ "maxValue": 255,
209
+ "defaultValue": 0,
210
+ "unsigned": true,
211
+ "options": [
212
+ {
213
+ "label": "Disable",
214
+ "value": 0
215
+ }
216
+ ]
217
+ },
218
+ {
219
+ "#": "12",
220
+ "label": "Switch S2: Scene ID (Double Click)",
221
+ "description": "Will be sent to the controller.",
222
+ "valueSize": 1,
223
+ "minValue": 0,
224
+ "maxValue": 255,
225
+ "defaultValue": 0,
226
+ "unsigned": true,
227
+ "options": [
228
+ {
229
+ "label": "Disable",
230
+ "value": 0
231
+ }
232
+ ]
233
+ },
234
+ {
235
+ "#": "13",
236
+ "label": "Switch S2: Scene ID (Hold)",
237
+ "description": "Momentary buttons only. Will be sent to the controller.",
238
+ "valueSize": 1,
239
+ "minValue": 0,
240
+ "maxValue": 255,
241
+ "defaultValue": 0,
242
+ "unsigned": true,
243
+ "options": [
244
+ {
245
+ "label": "Disabled",
246
+ "value": 0
247
+ }
248
+ ]
249
+ },
250
+ {
251
+ "#": "255",
252
+ "label": "Factory Reset",
253
+ "valueSize": 1,
254
+ "defaultValue": 0,
255
+ "unsigned": true,
256
+ "writeOnly": true,
257
+ "allowManualEntry": false,
258
+ "options": [
259
+ {
260
+ "label": "Idle",
261
+ "value": 0
262
+ },
263
+ {
264
+ "label": "Factory Reset",
265
+ "value": 85
266
+ }
267
+ ]
268
+ }
269
+ ]
270
+ }
@@ -2,7 +2,7 @@
2
2
  "manufacturer": "EbV",
3
3
  "manufacturerId": "0x017c",
4
4
  "label": "heatapp! floor",
5
- "description": "heatapp! floor is a controller for thermal actuators in underfloor heating installations and is part of the heatapp! system, providing individual circ",
5
+ "description": "8-channel underfloor heating controller",
6
6
  "devices": [
7
7
  {
8
8
  "productType": "0x0006",
@@ -16,7 +16,7 @@
16
16
  "paramInformation": [
17
17
  {
18
18
  "#": "1",
19
- "label": "Missing Radio Link time",
19
+ "label": "Missing Radio Link Time",
20
20
  "unit": "minutes",
21
21
  "valueSize": 1,
22
22
  "minValue": 10,
@@ -26,8 +26,7 @@
26
26
  },
27
27
  {
28
28
  "#": "2",
29
- "label": "Relay type",
30
- "description": "0 normal open, 1 normal close, 2 switching",
29
+ "label": "Relay Type",
31
30
  "valueSize": 1,
32
31
  "defaultValue": 0,
33
32
  "allowManualEntry": false,
@@ -46,5 +45,18 @@
46
45
  }
47
46
  ]
48
47
  }
49
- ]
48
+ ],
49
+ "compat": {
50
+ "overrideQueries": {
51
+ // The device has 8 sequential endpoints, but responds with random
52
+ // garbage when queried for its endpoint indizes
53
+ "Multi Channel": [
54
+ {
55
+ "method": "findEndpoints",
56
+ "result": [1, 2, 3, 4, 5, 6, 7, 8]
57
+ // No need to persist values, this is done as part of the interview
58
+ }
59
+ ]
60
+ }
61
+ }
50
62
  }
@@ -43,7 +43,7 @@
43
43
  "compat": {
44
44
  "commandClasses": {
45
45
  "remove": {
46
- "0x6c": {
46
+ "Supervision": {
47
47
  // The device does not support supervision although it is mandatory for the device type
48
48
  "endpoints": "*"
49
49
  }
@@ -23,7 +23,7 @@
23
23
  "commandClasses": {
24
24
  "remove": {
25
25
  // The device seems to report support for Supervision but ignores the commands
26
- "0x6c": {
26
+ "Supervision": {
27
27
  "endpoints": "*"
28
28
  }
29
29
  }
@@ -23,7 +23,7 @@
23
23
  "commandClasses": {
24
24
  "remove": {
25
25
  // The device seems to report support for Supervision but ignores the commands
26
- "0x6c": {
26
+ "Supervision": {
27
27
  "endpoints": "*"
28
28
  }
29
29
  }
@@ -23,7 +23,7 @@
23
23
  "commandClasses": {
24
24
  "remove": {
25
25
  // The device seems to report support for Supervision but ignores the commands
26
- "0x6c": {
26
+ "Supervision": {
27
27
  "endpoints": "*"
28
28
  }
29
29
  }