@seamapi/types 1.1186.0 → 1.1188.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -14186,56 +14186,9 @@ export type Routes = {
14186
14186
  * @deprecated use offline_access_codes_enabled*/
14187
14187
  supports_offline_access_codes?: boolean | undefined;
14188
14188
  /** Indicates current noise level in decibels, if the device supports noise detection. */
14189
- noise_level_decibels?: (number | null) | undefined;
14189
+ noise_level_decibels?: number | undefined;
14190
14190
  /** Array of noise threshold IDs that are currently triggering. */
14191
14191
  currently_triggering_noise_threshold_ids?: string[] | undefined;
14192
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
14193
- noise_level_nrs?: (number | null) | undefined;
14194
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
14195
- co2_ppm?: (number | null) | undefined;
14196
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
14197
- co_ppm?: (number | null) | undefined;
14198
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
14199
- air_quality_index?: (number | null) | undefined;
14200
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
14201
- mold_risk_level?: (string | null) | undefined;
14202
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
14203
- is_occupied?: (boolean | null) | undefined;
14204
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
14205
- occupant_count?: (number | null) | undefined;
14206
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
14207
- is_smoking_detected?: (boolean | null) | undefined;
14208
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
14209
- named_sensors?: {
14210
- /** Stable, hardware-defined name of the sensor, such as a port number. */
14211
- sensor_name: string;
14212
- /** Display name of the sensor. Defaults to `sensor_name`. */
14213
- display_name: string;
14214
- /** Reported temperature in °C. `null` until the first value arrives. */
14215
- temperature_celsius?: (number | null) | undefined;
14216
- /** Reported temperature in °F. `null` until the first value arrives. */
14217
- temperature_fahrenheit?: (number | null) | undefined;
14218
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
14219
- relative_humidity?: (number | null) | undefined;
14220
- /** Noise level in decibels. `null` until the first value arrives. */
14221
- noise_level_decibels?: (number | null) | undefined;
14222
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
14223
- noise_level_nrs?: (number | null) | undefined;
14224
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
14225
- co2_ppm?: (number | null) | undefined;
14226
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
14227
- co_ppm?: (number | null) | undefined;
14228
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
14229
- air_quality_index?: (number | null) | undefined;
14230
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
14231
- mold_risk_level?: (string | null) | undefined;
14232
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
14233
- is_occupied?: (boolean | null) | undefined;
14234
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
14235
- occupant_count?: (number | null) | undefined;
14236
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
14237
- is_smoking_detected?: (boolean | null) | undefined;
14238
- }[] | undefined;
14239
14192
  } & {
14240
14193
  /** ASSA ABLOY Credential Service metadata for the phone. */
14241
14194
  assa_abloy_credential_service_metadata?: ({
@@ -15080,11 +15033,11 @@ export type Routes = {
15080
15033
  } | undefined;
15081
15034
  } & {
15082
15035
  /** Reported temperature in °F. */
15083
- temperature_fahrenheit?: (number | null) | undefined;
15036
+ temperature_fahrenheit?: number | undefined;
15084
15037
  /** Reported temperature in °C. */
15085
- temperature_celsius?: (number | null) | undefined;
15038
+ temperature_celsius?: number | undefined;
15086
15039
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
15087
- relative_humidity?: (number | null) | undefined;
15040
+ relative_humidity?: number | undefined;
15088
15041
  /** HVAC mode settings that the thermostat supports. */
15089
15042
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
15090
15043
  /** Fan mode settings that the thermostat supports. */
@@ -15750,6 +15703,61 @@ export type Routes = {
15750
15703
  /** Image URL for the manufacturer logo. */
15751
15704
  image_url?: string | undefined;
15752
15705
  } | undefined;
15706
+ /** Temperature in °C, if the device measures temperature. */
15707
+ temperature_celsius?: number | undefined;
15708
+ /** Temperature in °F, if the device measures temperature. */
15709
+ temperature_fahrenheit?: number | undefined;
15710
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
15711
+ relative_humidity?: number | undefined;
15712
+ /** Noise level in decibels, if the device measures noise. */
15713
+ noise_level_decibels?: number | undefined;
15714
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
15715
+ noise_level_nrs?: number | undefined;
15716
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
15717
+ co2_ppm?: number | undefined;
15718
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
15719
+ co_ppm?: number | undefined;
15720
+ /** Air quality index, if the device measures it. */
15721
+ air_quality_index?: number | undefined;
15722
+ /** Mold risk level as reported by the device, if the device measures it. */
15723
+ mold_risk_level?: string | undefined;
15724
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
15725
+ is_occupied?: boolean | undefined;
15726
+ /** Number of occupants the device detects, if the device counts occupants. */
15727
+ occupant_count?: number | undefined;
15728
+ /** Indicates whether the device detects smoking, if the device measures it. */
15729
+ is_smoking_detected?: boolean | undefined;
15730
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
15731
+ named_sensors?: {
15732
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
15733
+ sensor_name: string;
15734
+ /** Display name of the sensor. Defaults to `sensor_name`. */
15735
+ display_name: string;
15736
+ /** Temperature in °C, if the device measures temperature. */
15737
+ temperature_celsius?: number | undefined;
15738
+ /** Temperature in °F, if the device measures temperature. */
15739
+ temperature_fahrenheit?: number | undefined;
15740
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
15741
+ relative_humidity?: number | undefined;
15742
+ /** Noise level in decibels, if the device measures noise. */
15743
+ noise_level_decibels?: number | undefined;
15744
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
15745
+ noise_level_nrs?: number | undefined;
15746
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
15747
+ co2_ppm?: number | undefined;
15748
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
15749
+ co_ppm?: number | undefined;
15750
+ /** Air quality index, if the device measures it. */
15751
+ air_quality_index?: number | undefined;
15752
+ /** Mold risk level as reported by the device, if the device measures it. */
15753
+ mold_risk_level?: string | undefined;
15754
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
15755
+ is_occupied?: boolean | undefined;
15756
+ /** Number of occupants the device detects, if the device counts occupants. */
15757
+ occupant_count?: number | undefined;
15758
+ /** Indicates whether the device detects smoking, if the device measures it. */
15759
+ is_smoking_detected?: boolean | undefined;
15760
+ }[] | undefined;
15753
15761
  /** Indicates whether the device supports remote unlocking. */
15754
15762
  can_remotely_unlock?: boolean | undefined;
15755
15763
  /** Indicates whether the device supports remote locking. */
@@ -22486,56 +22494,9 @@ export type Routes = {
22486
22494
  * @deprecated use offline_access_codes_enabled*/
22487
22495
  supports_offline_access_codes?: boolean | undefined;
22488
22496
  /** Indicates current noise level in decibels, if the device supports noise detection. */
22489
- noise_level_decibels?: (number | null) | undefined;
22497
+ noise_level_decibels?: number | undefined;
22490
22498
  /** Array of noise threshold IDs that are currently triggering. */
22491
22499
  currently_triggering_noise_threshold_ids?: string[] | undefined;
22492
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
22493
- noise_level_nrs?: (number | null) | undefined;
22494
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
22495
- co2_ppm?: (number | null) | undefined;
22496
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
22497
- co_ppm?: (number | null) | undefined;
22498
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
22499
- air_quality_index?: (number | null) | undefined;
22500
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
22501
- mold_risk_level?: (string | null) | undefined;
22502
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
22503
- is_occupied?: (boolean | null) | undefined;
22504
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
22505
- occupant_count?: (number | null) | undefined;
22506
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
22507
- is_smoking_detected?: (boolean | null) | undefined;
22508
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
22509
- named_sensors?: {
22510
- /** Stable, hardware-defined name of the sensor, such as a port number. */
22511
- sensor_name: string;
22512
- /** Display name of the sensor. Defaults to `sensor_name`. */
22513
- display_name: string;
22514
- /** Reported temperature in °C. `null` until the first value arrives. */
22515
- temperature_celsius?: (number | null) | undefined;
22516
- /** Reported temperature in °F. `null` until the first value arrives. */
22517
- temperature_fahrenheit?: (number | null) | undefined;
22518
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
22519
- relative_humidity?: (number | null) | undefined;
22520
- /** Noise level in decibels. `null` until the first value arrives. */
22521
- noise_level_decibels?: (number | null) | undefined;
22522
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
22523
- noise_level_nrs?: (number | null) | undefined;
22524
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
22525
- co2_ppm?: (number | null) | undefined;
22526
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
22527
- co_ppm?: (number | null) | undefined;
22528
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
22529
- air_quality_index?: (number | null) | undefined;
22530
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
22531
- mold_risk_level?: (string | null) | undefined;
22532
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
22533
- is_occupied?: (boolean | null) | undefined;
22534
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
22535
- occupant_count?: (number | null) | undefined;
22536
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
22537
- is_smoking_detected?: (boolean | null) | undefined;
22538
- }[] | undefined;
22539
22500
  } & {
22540
22501
  /** ASSA ABLOY Credential Service metadata for the phone. */
22541
22502
  assa_abloy_credential_service_metadata?: ({
@@ -23380,11 +23341,11 @@ export type Routes = {
23380
23341
  } | undefined;
23381
23342
  } & {
23382
23343
  /** Reported temperature in °F. */
23383
- temperature_fahrenheit?: (number | null) | undefined;
23344
+ temperature_fahrenheit?: number | undefined;
23384
23345
  /** Reported temperature in °C. */
23385
- temperature_celsius?: (number | null) | undefined;
23346
+ temperature_celsius?: number | undefined;
23386
23347
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
23387
- relative_humidity?: (number | null) | undefined;
23348
+ relative_humidity?: number | undefined;
23388
23349
  /** HVAC mode settings that the thermostat supports. */
23389
23350
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
23390
23351
  /** Fan mode settings that the thermostat supports. */
@@ -24050,6 +24011,61 @@ export type Routes = {
24050
24011
  /** Image URL for the manufacturer logo. */
24051
24012
  image_url?: string | undefined;
24052
24013
  } | undefined;
24014
+ /** Temperature in °C, if the device measures temperature. */
24015
+ temperature_celsius?: number | undefined;
24016
+ /** Temperature in °F, if the device measures temperature. */
24017
+ temperature_fahrenheit?: number | undefined;
24018
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
24019
+ relative_humidity?: number | undefined;
24020
+ /** Noise level in decibels, if the device measures noise. */
24021
+ noise_level_decibels?: number | undefined;
24022
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
24023
+ noise_level_nrs?: number | undefined;
24024
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
24025
+ co2_ppm?: number | undefined;
24026
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
24027
+ co_ppm?: number | undefined;
24028
+ /** Air quality index, if the device measures it. */
24029
+ air_quality_index?: number | undefined;
24030
+ /** Mold risk level as reported by the device, if the device measures it. */
24031
+ mold_risk_level?: string | undefined;
24032
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
24033
+ is_occupied?: boolean | undefined;
24034
+ /** Number of occupants the device detects, if the device counts occupants. */
24035
+ occupant_count?: number | undefined;
24036
+ /** Indicates whether the device detects smoking, if the device measures it. */
24037
+ is_smoking_detected?: boolean | undefined;
24038
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
24039
+ named_sensors?: {
24040
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
24041
+ sensor_name: string;
24042
+ /** Display name of the sensor. Defaults to `sensor_name`. */
24043
+ display_name: string;
24044
+ /** Temperature in °C, if the device measures temperature. */
24045
+ temperature_celsius?: number | undefined;
24046
+ /** Temperature in °F, if the device measures temperature. */
24047
+ temperature_fahrenheit?: number | undefined;
24048
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
24049
+ relative_humidity?: number | undefined;
24050
+ /** Noise level in decibels, if the device measures noise. */
24051
+ noise_level_decibels?: number | undefined;
24052
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
24053
+ noise_level_nrs?: number | undefined;
24054
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
24055
+ co2_ppm?: number | undefined;
24056
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
24057
+ co_ppm?: number | undefined;
24058
+ /** Air quality index, if the device measures it. */
24059
+ air_quality_index?: number | undefined;
24060
+ /** Mold risk level as reported by the device, if the device measures it. */
24061
+ mold_risk_level?: string | undefined;
24062
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
24063
+ is_occupied?: boolean | undefined;
24064
+ /** Number of occupants the device detects, if the device counts occupants. */
24065
+ occupant_count?: number | undefined;
24066
+ /** Indicates whether the device detects smoking, if the device measures it. */
24067
+ is_smoking_detected?: boolean | undefined;
24068
+ }[] | undefined;
24053
24069
  /** Indicates whether the device supports remote unlocking. */
24054
24070
  can_remotely_unlock?: boolean | undefined;
24055
24071
  /** Indicates whether the device supports remote locking. */
@@ -49061,6 +49077,8 @@ export type Routes = {
49061
49077
  allow_instant_key_customization?: boolean | undefined;
49062
49078
  /** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
49063
49079
  allow_notification_customization?: boolean | undefined;
49080
+ /** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
49081
+ allow_bridge_replacement?: boolean | undefined;
49064
49082
  } | undefined;
49065
49083
  } | undefined;
49066
49084
  } & {
@@ -50038,56 +50056,9 @@ export type Routes = {
50038
50056
  * @deprecated use offline_access_codes_enabled*/
50039
50057
  supports_offline_access_codes?: boolean | undefined;
50040
50058
  /** Indicates current noise level in decibels, if the device supports noise detection. */
50041
- noise_level_decibels?: (number | null) | undefined;
50059
+ noise_level_decibels?: number | undefined;
50042
50060
  /** Array of noise threshold IDs that are currently triggering. */
50043
50061
  currently_triggering_noise_threshold_ids?: string[] | undefined;
50044
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
50045
- noise_level_nrs?: (number | null) | undefined;
50046
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
50047
- co2_ppm?: (number | null) | undefined;
50048
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
50049
- co_ppm?: (number | null) | undefined;
50050
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
50051
- air_quality_index?: (number | null) | undefined;
50052
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
50053
- mold_risk_level?: (string | null) | undefined;
50054
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
50055
- is_occupied?: (boolean | null) | undefined;
50056
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
50057
- occupant_count?: (number | null) | undefined;
50058
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
50059
- is_smoking_detected?: (boolean | null) | undefined;
50060
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
50061
- named_sensors?: {
50062
- /** Stable, hardware-defined name of the sensor, such as a port number. */
50063
- sensor_name: string;
50064
- /** Display name of the sensor. Defaults to `sensor_name`. */
50065
- display_name: string;
50066
- /** Reported temperature in °C. `null` until the first value arrives. */
50067
- temperature_celsius?: (number | null) | undefined;
50068
- /** Reported temperature in °F. `null` until the first value arrives. */
50069
- temperature_fahrenheit?: (number | null) | undefined;
50070
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
50071
- relative_humidity?: (number | null) | undefined;
50072
- /** Noise level in decibels. `null` until the first value arrives. */
50073
- noise_level_decibels?: (number | null) | undefined;
50074
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
50075
- noise_level_nrs?: (number | null) | undefined;
50076
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
50077
- co2_ppm?: (number | null) | undefined;
50078
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
50079
- co_ppm?: (number | null) | undefined;
50080
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
50081
- air_quality_index?: (number | null) | undefined;
50082
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
50083
- mold_risk_level?: (string | null) | undefined;
50084
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
50085
- is_occupied?: (boolean | null) | undefined;
50086
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
50087
- occupant_count?: (number | null) | undefined;
50088
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
50089
- is_smoking_detected?: (boolean | null) | undefined;
50090
- }[] | undefined;
50091
50062
  } & {
50092
50063
  /** ASSA ABLOY Credential Service metadata for the phone. */
50093
50064
  assa_abloy_credential_service_metadata?: ({
@@ -50932,11 +50903,11 @@ export type Routes = {
50932
50903
  } | undefined;
50933
50904
  } & {
50934
50905
  /** Reported temperature in °F. */
50935
- temperature_fahrenheit?: (number | null) | undefined;
50906
+ temperature_fahrenheit?: number | undefined;
50936
50907
  /** Reported temperature in °C. */
50937
- temperature_celsius?: (number | null) | undefined;
50908
+ temperature_celsius?: number | undefined;
50938
50909
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
50939
- relative_humidity?: (number | null) | undefined;
50910
+ relative_humidity?: number | undefined;
50940
50911
  /** HVAC mode settings that the thermostat supports. */
50941
50912
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
50942
50913
  /** Fan mode settings that the thermostat supports. */
@@ -51602,6 +51573,61 @@ export type Routes = {
51602
51573
  /** Image URL for the manufacturer logo. */
51603
51574
  image_url?: string | undefined;
51604
51575
  } | undefined;
51576
+ /** Temperature in °C, if the device measures temperature. */
51577
+ temperature_celsius?: number | undefined;
51578
+ /** Temperature in °F, if the device measures temperature. */
51579
+ temperature_fahrenheit?: number | undefined;
51580
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
51581
+ relative_humidity?: number | undefined;
51582
+ /** Noise level in decibels, if the device measures noise. */
51583
+ noise_level_decibels?: number | undefined;
51584
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
51585
+ noise_level_nrs?: number | undefined;
51586
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
51587
+ co2_ppm?: number | undefined;
51588
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
51589
+ co_ppm?: number | undefined;
51590
+ /** Air quality index, if the device measures it. */
51591
+ air_quality_index?: number | undefined;
51592
+ /** Mold risk level as reported by the device, if the device measures it. */
51593
+ mold_risk_level?: string | undefined;
51594
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
51595
+ is_occupied?: boolean | undefined;
51596
+ /** Number of occupants the device detects, if the device counts occupants. */
51597
+ occupant_count?: number | undefined;
51598
+ /** Indicates whether the device detects smoking, if the device measures it. */
51599
+ is_smoking_detected?: boolean | undefined;
51600
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
51601
+ named_sensors?: {
51602
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
51603
+ sensor_name: string;
51604
+ /** Display name of the sensor. Defaults to `sensor_name`. */
51605
+ display_name: string;
51606
+ /** Temperature in °C, if the device measures temperature. */
51607
+ temperature_celsius?: number | undefined;
51608
+ /** Temperature in °F, if the device measures temperature. */
51609
+ temperature_fahrenheit?: number | undefined;
51610
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
51611
+ relative_humidity?: number | undefined;
51612
+ /** Noise level in decibels, if the device measures noise. */
51613
+ noise_level_decibels?: number | undefined;
51614
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
51615
+ noise_level_nrs?: number | undefined;
51616
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
51617
+ co2_ppm?: number | undefined;
51618
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
51619
+ co_ppm?: number | undefined;
51620
+ /** Air quality index, if the device measures it. */
51621
+ air_quality_index?: number | undefined;
51622
+ /** Mold risk level as reported by the device, if the device measures it. */
51623
+ mold_risk_level?: string | undefined;
51624
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
51625
+ is_occupied?: boolean | undefined;
51626
+ /** Number of occupants the device detects, if the device counts occupants. */
51627
+ occupant_count?: number | undefined;
51628
+ /** Indicates whether the device detects smoking, if the device measures it. */
51629
+ is_smoking_detected?: boolean | undefined;
51630
+ }[] | undefined;
51605
51631
  /** Indicates whether the device supports remote unlocking. */
51606
51632
  can_remotely_unlock?: boolean | undefined;
51607
51633
  /** Indicates whether the device supports remote locking. */
@@ -51814,56 +51840,9 @@ export type Routes = {
51814
51840
  * @deprecated use offline_access_codes_enabled*/
51815
51841
  supports_offline_access_codes?: boolean | undefined;
51816
51842
  /** Indicates current noise level in decibels, if the device supports noise detection. */
51817
- noise_level_decibels?: (number | null) | undefined;
51843
+ noise_level_decibels?: number | undefined;
51818
51844
  /** Array of noise threshold IDs that are currently triggering. */
51819
51845
  currently_triggering_noise_threshold_ids?: string[] | undefined;
51820
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
51821
- noise_level_nrs?: (number | null) | undefined;
51822
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
51823
- co2_ppm?: (number | null) | undefined;
51824
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
51825
- co_ppm?: (number | null) | undefined;
51826
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
51827
- air_quality_index?: (number | null) | undefined;
51828
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
51829
- mold_risk_level?: (string | null) | undefined;
51830
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
51831
- is_occupied?: (boolean | null) | undefined;
51832
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
51833
- occupant_count?: (number | null) | undefined;
51834
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
51835
- is_smoking_detected?: (boolean | null) | undefined;
51836
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
51837
- named_sensors?: {
51838
- /** Stable, hardware-defined name of the sensor, such as a port number. */
51839
- sensor_name: string;
51840
- /** Display name of the sensor. Defaults to `sensor_name`. */
51841
- display_name: string;
51842
- /** Reported temperature in °C. `null` until the first value arrives. */
51843
- temperature_celsius?: (number | null) | undefined;
51844
- /** Reported temperature in °F. `null` until the first value arrives. */
51845
- temperature_fahrenheit?: (number | null) | undefined;
51846
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
51847
- relative_humidity?: (number | null) | undefined;
51848
- /** Noise level in decibels. `null` until the first value arrives. */
51849
- noise_level_decibels?: (number | null) | undefined;
51850
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
51851
- noise_level_nrs?: (number | null) | undefined;
51852
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
51853
- co2_ppm?: (number | null) | undefined;
51854
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
51855
- co_ppm?: (number | null) | undefined;
51856
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
51857
- air_quality_index?: (number | null) | undefined;
51858
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
51859
- mold_risk_level?: (string | null) | undefined;
51860
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
51861
- is_occupied?: (boolean | null) | undefined;
51862
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
51863
- occupant_count?: (number | null) | undefined;
51864
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
51865
- is_smoking_detected?: (boolean | null) | undefined;
51866
- }[] | undefined;
51867
51846
  } & {
51868
51847
  /** ASSA ABLOY Credential Service metadata for the phone. */
51869
51848
  assa_abloy_credential_service_metadata?: ({
@@ -52708,11 +52687,11 @@ export type Routes = {
52708
52687
  } | undefined;
52709
52688
  } & {
52710
52689
  /** Reported temperature in °F. */
52711
- temperature_fahrenheit?: (number | null) | undefined;
52690
+ temperature_fahrenheit?: number | undefined;
52712
52691
  /** Reported temperature in °C. */
52713
- temperature_celsius?: (number | null) | undefined;
52692
+ temperature_celsius?: number | undefined;
52714
52693
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
52715
- relative_humidity?: (number | null) | undefined;
52694
+ relative_humidity?: number | undefined;
52716
52695
  /** HVAC mode settings that the thermostat supports. */
52717
52696
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
52718
52697
  /** Fan mode settings that the thermostat supports. */
@@ -53378,6 +53357,61 @@ export type Routes = {
53378
53357
  /** Image URL for the manufacturer logo. */
53379
53358
  image_url?: string | undefined;
53380
53359
  } | undefined;
53360
+ /** Temperature in °C, if the device measures temperature. */
53361
+ temperature_celsius?: number | undefined;
53362
+ /** Temperature in °F, if the device measures temperature. */
53363
+ temperature_fahrenheit?: number | undefined;
53364
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
53365
+ relative_humidity?: number | undefined;
53366
+ /** Noise level in decibels, if the device measures noise. */
53367
+ noise_level_decibels?: number | undefined;
53368
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
53369
+ noise_level_nrs?: number | undefined;
53370
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
53371
+ co2_ppm?: number | undefined;
53372
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
53373
+ co_ppm?: number | undefined;
53374
+ /** Air quality index, if the device measures it. */
53375
+ air_quality_index?: number | undefined;
53376
+ /** Mold risk level as reported by the device, if the device measures it. */
53377
+ mold_risk_level?: string | undefined;
53378
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
53379
+ is_occupied?: boolean | undefined;
53380
+ /** Number of occupants the device detects, if the device counts occupants. */
53381
+ occupant_count?: number | undefined;
53382
+ /** Indicates whether the device detects smoking, if the device measures it. */
53383
+ is_smoking_detected?: boolean | undefined;
53384
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
53385
+ named_sensors?: {
53386
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
53387
+ sensor_name: string;
53388
+ /** Display name of the sensor. Defaults to `sensor_name`. */
53389
+ display_name: string;
53390
+ /** Temperature in °C, if the device measures temperature. */
53391
+ temperature_celsius?: number | undefined;
53392
+ /** Temperature in °F, if the device measures temperature. */
53393
+ temperature_fahrenheit?: number | undefined;
53394
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
53395
+ relative_humidity?: number | undefined;
53396
+ /** Noise level in decibels, if the device measures noise. */
53397
+ noise_level_decibels?: number | undefined;
53398
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
53399
+ noise_level_nrs?: number | undefined;
53400
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
53401
+ co2_ppm?: number | undefined;
53402
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
53403
+ co_ppm?: number | undefined;
53404
+ /** Air quality index, if the device measures it. */
53405
+ air_quality_index?: number | undefined;
53406
+ /** Mold risk level as reported by the device, if the device measures it. */
53407
+ mold_risk_level?: string | undefined;
53408
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
53409
+ is_occupied?: boolean | undefined;
53410
+ /** Number of occupants the device detects, if the device counts occupants. */
53411
+ occupant_count?: number | undefined;
53412
+ /** Indicates whether the device detects smoking, if the device measures it. */
53413
+ is_smoking_detected?: boolean | undefined;
53414
+ }[] | undefined;
53381
53415
  /** Indicates whether the device supports remote unlocking. */
53382
53416
  can_remotely_unlock?: boolean | undefined;
53383
53417
  /** Indicates whether the device supports remote locking. */
@@ -64831,56 +64865,9 @@ export type Routes = {
64831
64865
  * @deprecated use offline_access_codes_enabled*/
64832
64866
  supports_offline_access_codes?: boolean | undefined;
64833
64867
  /** Indicates current noise level in decibels, if the device supports noise detection. */
64834
- noise_level_decibels?: (number | null) | undefined;
64868
+ noise_level_decibels?: number | undefined;
64835
64869
  /** Array of noise threshold IDs that are currently triggering. */
64836
64870
  currently_triggering_noise_threshold_ids?: string[] | undefined;
64837
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
64838
- noise_level_nrs?: (number | null) | undefined;
64839
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
64840
- co2_ppm?: (number | null) | undefined;
64841
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
64842
- co_ppm?: (number | null) | undefined;
64843
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
64844
- air_quality_index?: (number | null) | undefined;
64845
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
64846
- mold_risk_level?: (string | null) | undefined;
64847
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
64848
- is_occupied?: (boolean | null) | undefined;
64849
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
64850
- occupant_count?: (number | null) | undefined;
64851
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
64852
- is_smoking_detected?: (boolean | null) | undefined;
64853
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
64854
- named_sensors?: {
64855
- /** Stable, hardware-defined name of the sensor, such as a port number. */
64856
- sensor_name: string;
64857
- /** Display name of the sensor. Defaults to `sensor_name`. */
64858
- display_name: string;
64859
- /** Reported temperature in °C. `null` until the first value arrives. */
64860
- temperature_celsius?: (number | null) | undefined;
64861
- /** Reported temperature in °F. `null` until the first value arrives. */
64862
- temperature_fahrenheit?: (number | null) | undefined;
64863
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
64864
- relative_humidity?: (number | null) | undefined;
64865
- /** Noise level in decibels. `null` until the first value arrives. */
64866
- noise_level_decibels?: (number | null) | undefined;
64867
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
64868
- noise_level_nrs?: (number | null) | undefined;
64869
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
64870
- co2_ppm?: (number | null) | undefined;
64871
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
64872
- co_ppm?: (number | null) | undefined;
64873
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
64874
- air_quality_index?: (number | null) | undefined;
64875
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
64876
- mold_risk_level?: (string | null) | undefined;
64877
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
64878
- is_occupied?: (boolean | null) | undefined;
64879
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
64880
- occupant_count?: (number | null) | undefined;
64881
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
64882
- is_smoking_detected?: (boolean | null) | undefined;
64883
- }[] | undefined;
64884
64871
  } & {
64885
64872
  /** ASSA ABLOY Credential Service metadata for the phone. */
64886
64873
  assa_abloy_credential_service_metadata?: ({
@@ -65725,11 +65712,11 @@ export type Routes = {
65725
65712
  } | undefined;
65726
65713
  } & {
65727
65714
  /** Reported temperature in °F. */
65728
- temperature_fahrenheit?: (number | null) | undefined;
65715
+ temperature_fahrenheit?: number | undefined;
65729
65716
  /** Reported temperature in °C. */
65730
- temperature_celsius?: (number | null) | undefined;
65717
+ temperature_celsius?: number | undefined;
65731
65718
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
65732
- relative_humidity?: (number | null) | undefined;
65719
+ relative_humidity?: number | undefined;
65733
65720
  /** HVAC mode settings that the thermostat supports. */
65734
65721
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
65735
65722
  /** Fan mode settings that the thermostat supports. */
@@ -66395,6 +66382,61 @@ export type Routes = {
66395
66382
  /** Image URL for the manufacturer logo. */
66396
66383
  image_url?: string | undefined;
66397
66384
  } | undefined;
66385
+ /** Temperature in °C, if the device measures temperature. */
66386
+ temperature_celsius?: number | undefined;
66387
+ /** Temperature in °F, if the device measures temperature. */
66388
+ temperature_fahrenheit?: number | undefined;
66389
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
66390
+ relative_humidity?: number | undefined;
66391
+ /** Noise level in decibels, if the device measures noise. */
66392
+ noise_level_decibels?: number | undefined;
66393
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
66394
+ noise_level_nrs?: number | undefined;
66395
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
66396
+ co2_ppm?: number | undefined;
66397
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
66398
+ co_ppm?: number | undefined;
66399
+ /** Air quality index, if the device measures it. */
66400
+ air_quality_index?: number | undefined;
66401
+ /** Mold risk level as reported by the device, if the device measures it. */
66402
+ mold_risk_level?: string | undefined;
66403
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
66404
+ is_occupied?: boolean | undefined;
66405
+ /** Number of occupants the device detects, if the device counts occupants. */
66406
+ occupant_count?: number | undefined;
66407
+ /** Indicates whether the device detects smoking, if the device measures it. */
66408
+ is_smoking_detected?: boolean | undefined;
66409
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
66410
+ named_sensors?: {
66411
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
66412
+ sensor_name: string;
66413
+ /** Display name of the sensor. Defaults to `sensor_name`. */
66414
+ display_name: string;
66415
+ /** Temperature in °C, if the device measures temperature. */
66416
+ temperature_celsius?: number | undefined;
66417
+ /** Temperature in °F, if the device measures temperature. */
66418
+ temperature_fahrenheit?: number | undefined;
66419
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
66420
+ relative_humidity?: number | undefined;
66421
+ /** Noise level in decibels, if the device measures noise. */
66422
+ noise_level_decibels?: number | undefined;
66423
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
66424
+ noise_level_nrs?: number | undefined;
66425
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
66426
+ co2_ppm?: number | undefined;
66427
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
66428
+ co_ppm?: number | undefined;
66429
+ /** Air quality index, if the device measures it. */
66430
+ air_quality_index?: number | undefined;
66431
+ /** Mold risk level as reported by the device, if the device measures it. */
66432
+ mold_risk_level?: string | undefined;
66433
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
66434
+ is_occupied?: boolean | undefined;
66435
+ /** Number of occupants the device detects, if the device counts occupants. */
66436
+ occupant_count?: number | undefined;
66437
+ /** Indicates whether the device detects smoking, if the device measures it. */
66438
+ is_smoking_detected?: boolean | undefined;
66439
+ }[] | undefined;
66398
66440
  /** Indicates whether the device supports remote unlocking. */
66399
66441
  can_remotely_unlock?: boolean | undefined;
66400
66442
  /** Indicates whether the device supports remote locking. */
@@ -66557,56 +66599,9 @@ export type Routes = {
66557
66599
  * @deprecated use offline_access_codes_enabled*/
66558
66600
  supports_offline_access_codes?: boolean | undefined;
66559
66601
  /** Indicates current noise level in decibels, if the device supports noise detection. */
66560
- noise_level_decibels?: (number | null) | undefined;
66602
+ noise_level_decibels?: number | undefined;
66561
66603
  /** Array of noise threshold IDs that are currently triggering. */
66562
66604
  currently_triggering_noise_threshold_ids?: string[] | undefined;
66563
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
66564
- noise_level_nrs?: (number | null) | undefined;
66565
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
66566
- co2_ppm?: (number | null) | undefined;
66567
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
66568
- co_ppm?: (number | null) | undefined;
66569
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
66570
- air_quality_index?: (number | null) | undefined;
66571
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
66572
- mold_risk_level?: (string | null) | undefined;
66573
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
66574
- is_occupied?: (boolean | null) | undefined;
66575
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
66576
- occupant_count?: (number | null) | undefined;
66577
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
66578
- is_smoking_detected?: (boolean | null) | undefined;
66579
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
66580
- named_sensors?: {
66581
- /** Stable, hardware-defined name of the sensor, such as a port number. */
66582
- sensor_name: string;
66583
- /** Display name of the sensor. Defaults to `sensor_name`. */
66584
- display_name: string;
66585
- /** Reported temperature in °C. `null` until the first value arrives. */
66586
- temperature_celsius?: (number | null) | undefined;
66587
- /** Reported temperature in °F. `null` until the first value arrives. */
66588
- temperature_fahrenheit?: (number | null) | undefined;
66589
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
66590
- relative_humidity?: (number | null) | undefined;
66591
- /** Noise level in decibels. `null` until the first value arrives. */
66592
- noise_level_decibels?: (number | null) | undefined;
66593
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
66594
- noise_level_nrs?: (number | null) | undefined;
66595
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
66596
- co2_ppm?: (number | null) | undefined;
66597
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
66598
- co_ppm?: (number | null) | undefined;
66599
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
66600
- air_quality_index?: (number | null) | undefined;
66601
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
66602
- mold_risk_level?: (string | null) | undefined;
66603
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
66604
- is_occupied?: (boolean | null) | undefined;
66605
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
66606
- occupant_count?: (number | null) | undefined;
66607
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
66608
- is_smoking_detected?: (boolean | null) | undefined;
66609
- }[] | undefined;
66610
66605
  } & {
66611
66606
  /** ASSA ABLOY Credential Service metadata for the phone. */
66612
66607
  assa_abloy_credential_service_metadata?: ({
@@ -67451,11 +67446,11 @@ export type Routes = {
67451
67446
  } | undefined;
67452
67447
  } & {
67453
67448
  /** Reported temperature in °F. */
67454
- temperature_fahrenheit?: (number | null) | undefined;
67449
+ temperature_fahrenheit?: number | undefined;
67455
67450
  /** Reported temperature in °C. */
67456
- temperature_celsius?: (number | null) | undefined;
67451
+ temperature_celsius?: number | undefined;
67457
67452
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
67458
- relative_humidity?: (number | null) | undefined;
67453
+ relative_humidity?: number | undefined;
67459
67454
  /** HVAC mode settings that the thermostat supports. */
67460
67455
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
67461
67456
  /** Fan mode settings that the thermostat supports. */
@@ -68121,6 +68116,61 @@ export type Routes = {
68121
68116
  /** Image URL for the manufacturer logo. */
68122
68117
  image_url?: string | undefined;
68123
68118
  } | undefined;
68119
+ /** Temperature in °C, if the device measures temperature. */
68120
+ temperature_celsius?: number | undefined;
68121
+ /** Temperature in °F, if the device measures temperature. */
68122
+ temperature_fahrenheit?: number | undefined;
68123
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
68124
+ relative_humidity?: number | undefined;
68125
+ /** Noise level in decibels, if the device measures noise. */
68126
+ noise_level_decibels?: number | undefined;
68127
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
68128
+ noise_level_nrs?: number | undefined;
68129
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
68130
+ co2_ppm?: number | undefined;
68131
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
68132
+ co_ppm?: number | undefined;
68133
+ /** Air quality index, if the device measures it. */
68134
+ air_quality_index?: number | undefined;
68135
+ /** Mold risk level as reported by the device, if the device measures it. */
68136
+ mold_risk_level?: string | undefined;
68137
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
68138
+ is_occupied?: boolean | undefined;
68139
+ /** Number of occupants the device detects, if the device counts occupants. */
68140
+ occupant_count?: number | undefined;
68141
+ /** Indicates whether the device detects smoking, if the device measures it. */
68142
+ is_smoking_detected?: boolean | undefined;
68143
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
68144
+ named_sensors?: {
68145
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
68146
+ sensor_name: string;
68147
+ /** Display name of the sensor. Defaults to `sensor_name`. */
68148
+ display_name: string;
68149
+ /** Temperature in °C, if the device measures temperature. */
68150
+ temperature_celsius?: number | undefined;
68151
+ /** Temperature in °F, if the device measures temperature. */
68152
+ temperature_fahrenheit?: number | undefined;
68153
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
68154
+ relative_humidity?: number | undefined;
68155
+ /** Noise level in decibels, if the device measures noise. */
68156
+ noise_level_decibels?: number | undefined;
68157
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
68158
+ noise_level_nrs?: number | undefined;
68159
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
68160
+ co2_ppm?: number | undefined;
68161
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
68162
+ co_ppm?: number | undefined;
68163
+ /** Air quality index, if the device measures it. */
68164
+ air_quality_index?: number | undefined;
68165
+ /** Mold risk level as reported by the device, if the device measures it. */
68166
+ mold_risk_level?: string | undefined;
68167
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
68168
+ is_occupied?: boolean | undefined;
68169
+ /** Number of occupants the device detects, if the device counts occupants. */
68170
+ occupant_count?: number | undefined;
68171
+ /** Indicates whether the device detects smoking, if the device measures it. */
68172
+ is_smoking_detected?: boolean | undefined;
68173
+ }[] | undefined;
68124
68174
  /** Indicates whether the device supports remote unlocking. */
68125
68175
  can_remotely_unlock?: boolean | undefined;
68126
68176
  /** Indicates whether the device supports remote locking. */
@@ -68306,56 +68356,9 @@ export type Routes = {
68306
68356
  * @deprecated use offline_access_codes_enabled*/
68307
68357
  supports_offline_access_codes?: boolean | undefined;
68308
68358
  /** Indicates current noise level in decibels, if the device supports noise detection. */
68309
- noise_level_decibels?: (number | null) | undefined;
68359
+ noise_level_decibels?: number | undefined;
68310
68360
  /** Array of noise threshold IDs that are currently triggering. */
68311
68361
  currently_triggering_noise_threshold_ids?: string[] | undefined;
68312
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
68313
- noise_level_nrs?: (number | null) | undefined;
68314
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
68315
- co2_ppm?: (number | null) | undefined;
68316
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
68317
- co_ppm?: (number | null) | undefined;
68318
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
68319
- air_quality_index?: (number | null) | undefined;
68320
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
68321
- mold_risk_level?: (string | null) | undefined;
68322
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
68323
- is_occupied?: (boolean | null) | undefined;
68324
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
68325
- occupant_count?: (number | null) | undefined;
68326
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
68327
- is_smoking_detected?: (boolean | null) | undefined;
68328
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
68329
- named_sensors?: {
68330
- /** Stable, hardware-defined name of the sensor, such as a port number. */
68331
- sensor_name: string;
68332
- /** Display name of the sensor. Defaults to `sensor_name`. */
68333
- display_name: string;
68334
- /** Reported temperature in °C. `null` until the first value arrives. */
68335
- temperature_celsius?: (number | null) | undefined;
68336
- /** Reported temperature in °F. `null` until the first value arrives. */
68337
- temperature_fahrenheit?: (number | null) | undefined;
68338
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
68339
- relative_humidity?: (number | null) | undefined;
68340
- /** Noise level in decibels. `null` until the first value arrives. */
68341
- noise_level_decibels?: (number | null) | undefined;
68342
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
68343
- noise_level_nrs?: (number | null) | undefined;
68344
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
68345
- co2_ppm?: (number | null) | undefined;
68346
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
68347
- co_ppm?: (number | null) | undefined;
68348
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
68349
- air_quality_index?: (number | null) | undefined;
68350
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
68351
- mold_risk_level?: (string | null) | undefined;
68352
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
68353
- is_occupied?: (boolean | null) | undefined;
68354
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
68355
- occupant_count?: (number | null) | undefined;
68356
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
68357
- is_smoking_detected?: (boolean | null) | undefined;
68358
- }[] | undefined;
68359
68362
  } & {
68360
68363
  /** ASSA ABLOY Credential Service metadata for the phone. */
68361
68364
  assa_abloy_credential_service_metadata?: ({
@@ -69200,11 +69203,11 @@ export type Routes = {
69200
69203
  } | undefined;
69201
69204
  } & {
69202
69205
  /** Reported temperature in °F. */
69203
- temperature_fahrenheit?: (number | null) | undefined;
69206
+ temperature_fahrenheit?: number | undefined;
69204
69207
  /** Reported temperature in °C. */
69205
- temperature_celsius?: (number | null) | undefined;
69208
+ temperature_celsius?: number | undefined;
69206
69209
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
69207
- relative_humidity?: (number | null) | undefined;
69210
+ relative_humidity?: number | undefined;
69208
69211
  /** HVAC mode settings that the thermostat supports. */
69209
69212
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
69210
69213
  /** Fan mode settings that the thermostat supports. */
@@ -69870,6 +69873,61 @@ export type Routes = {
69870
69873
  /** Image URL for the manufacturer logo. */
69871
69874
  image_url?: string | undefined;
69872
69875
  } | undefined;
69876
+ /** Temperature in °C, if the device measures temperature. */
69877
+ temperature_celsius?: number | undefined;
69878
+ /** Temperature in °F, if the device measures temperature. */
69879
+ temperature_fahrenheit?: number | undefined;
69880
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
69881
+ relative_humidity?: number | undefined;
69882
+ /** Noise level in decibels, if the device measures noise. */
69883
+ noise_level_decibels?: number | undefined;
69884
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
69885
+ noise_level_nrs?: number | undefined;
69886
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
69887
+ co2_ppm?: number | undefined;
69888
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
69889
+ co_ppm?: number | undefined;
69890
+ /** Air quality index, if the device measures it. */
69891
+ air_quality_index?: number | undefined;
69892
+ /** Mold risk level as reported by the device, if the device measures it. */
69893
+ mold_risk_level?: string | undefined;
69894
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
69895
+ is_occupied?: boolean | undefined;
69896
+ /** Number of occupants the device detects, if the device counts occupants. */
69897
+ occupant_count?: number | undefined;
69898
+ /** Indicates whether the device detects smoking, if the device measures it. */
69899
+ is_smoking_detected?: boolean | undefined;
69900
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
69901
+ named_sensors?: {
69902
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
69903
+ sensor_name: string;
69904
+ /** Display name of the sensor. Defaults to `sensor_name`. */
69905
+ display_name: string;
69906
+ /** Temperature in °C, if the device measures temperature. */
69907
+ temperature_celsius?: number | undefined;
69908
+ /** Temperature in °F, if the device measures temperature. */
69909
+ temperature_fahrenheit?: number | undefined;
69910
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
69911
+ relative_humidity?: number | undefined;
69912
+ /** Noise level in decibels, if the device measures noise. */
69913
+ noise_level_decibels?: number | undefined;
69914
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
69915
+ noise_level_nrs?: number | undefined;
69916
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
69917
+ co2_ppm?: number | undefined;
69918
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
69919
+ co_ppm?: number | undefined;
69920
+ /** Air quality index, if the device measures it. */
69921
+ air_quality_index?: number | undefined;
69922
+ /** Mold risk level as reported by the device, if the device measures it. */
69923
+ mold_risk_level?: string | undefined;
69924
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
69925
+ is_occupied?: boolean | undefined;
69926
+ /** Number of occupants the device detects, if the device counts occupants. */
69927
+ occupant_count?: number | undefined;
69928
+ /** Indicates whether the device detects smoking, if the device measures it. */
69929
+ is_smoking_detected?: boolean | undefined;
69930
+ }[] | undefined;
69873
69931
  /** Indicates whether the device supports remote unlocking. */
69874
69932
  can_remotely_unlock?: boolean | undefined;
69875
69933
  /** Indicates whether the device supports remote locking. */
@@ -70031,56 +70089,9 @@ export type Routes = {
70031
70089
  * @deprecated use offline_access_codes_enabled*/
70032
70090
  supports_offline_access_codes?: boolean | undefined;
70033
70091
  /** Indicates current noise level in decibels, if the device supports noise detection. */
70034
- noise_level_decibels?: (number | null) | undefined;
70092
+ noise_level_decibels?: number | undefined;
70035
70093
  /** Array of noise threshold IDs that are currently triggering. */
70036
70094
  currently_triggering_noise_threshold_ids?: string[] | undefined;
70037
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
70038
- noise_level_nrs?: (number | null) | undefined;
70039
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
70040
- co2_ppm?: (number | null) | undefined;
70041
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
70042
- co_ppm?: (number | null) | undefined;
70043
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
70044
- air_quality_index?: (number | null) | undefined;
70045
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
70046
- mold_risk_level?: (string | null) | undefined;
70047
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
70048
- is_occupied?: (boolean | null) | undefined;
70049
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
70050
- occupant_count?: (number | null) | undefined;
70051
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
70052
- is_smoking_detected?: (boolean | null) | undefined;
70053
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
70054
- named_sensors?: {
70055
- /** Stable, hardware-defined name of the sensor, such as a port number. */
70056
- sensor_name: string;
70057
- /** Display name of the sensor. Defaults to `sensor_name`. */
70058
- display_name: string;
70059
- /** Reported temperature in °C. `null` until the first value arrives. */
70060
- temperature_celsius?: (number | null) | undefined;
70061
- /** Reported temperature in °F. `null` until the first value arrives. */
70062
- temperature_fahrenheit?: (number | null) | undefined;
70063
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
70064
- relative_humidity?: (number | null) | undefined;
70065
- /** Noise level in decibels. `null` until the first value arrives. */
70066
- noise_level_decibels?: (number | null) | undefined;
70067
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
70068
- noise_level_nrs?: (number | null) | undefined;
70069
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
70070
- co2_ppm?: (number | null) | undefined;
70071
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
70072
- co_ppm?: (number | null) | undefined;
70073
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
70074
- air_quality_index?: (number | null) | undefined;
70075
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
70076
- mold_risk_level?: (string | null) | undefined;
70077
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
70078
- is_occupied?: (boolean | null) | undefined;
70079
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
70080
- occupant_count?: (number | null) | undefined;
70081
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
70082
- is_smoking_detected?: (boolean | null) | undefined;
70083
- }[] | undefined;
70084
70095
  } & {
70085
70096
  /** ASSA ABLOY Credential Service metadata for the phone. */
70086
70097
  assa_abloy_credential_service_metadata?: ({
@@ -70925,11 +70936,11 @@ export type Routes = {
70925
70936
  } | undefined;
70926
70937
  } & {
70927
70938
  /** Reported temperature in °F. */
70928
- temperature_fahrenheit?: (number | null) | undefined;
70939
+ temperature_fahrenheit?: number | undefined;
70929
70940
  /** Reported temperature in °C. */
70930
- temperature_celsius?: (number | null) | undefined;
70941
+ temperature_celsius?: number | undefined;
70931
70942
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
70932
- relative_humidity?: (number | null) | undefined;
70943
+ relative_humidity?: number | undefined;
70933
70944
  /** HVAC mode settings that the thermostat supports. */
70934
70945
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
70935
70946
  /** Fan mode settings that the thermostat supports. */
@@ -71595,6 +71606,61 @@ export type Routes = {
71595
71606
  /** Image URL for the manufacturer logo. */
71596
71607
  image_url?: string | undefined;
71597
71608
  } | undefined;
71609
+ /** Temperature in °C, if the device measures temperature. */
71610
+ temperature_celsius?: number | undefined;
71611
+ /** Temperature in °F, if the device measures temperature. */
71612
+ temperature_fahrenheit?: number | undefined;
71613
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
71614
+ relative_humidity?: number | undefined;
71615
+ /** Noise level in decibels, if the device measures noise. */
71616
+ noise_level_decibels?: number | undefined;
71617
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
71618
+ noise_level_nrs?: number | undefined;
71619
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
71620
+ co2_ppm?: number | undefined;
71621
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
71622
+ co_ppm?: number | undefined;
71623
+ /** Air quality index, if the device measures it. */
71624
+ air_quality_index?: number | undefined;
71625
+ /** Mold risk level as reported by the device, if the device measures it. */
71626
+ mold_risk_level?: string | undefined;
71627
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
71628
+ is_occupied?: boolean | undefined;
71629
+ /** Number of occupants the device detects, if the device counts occupants. */
71630
+ occupant_count?: number | undefined;
71631
+ /** Indicates whether the device detects smoking, if the device measures it. */
71632
+ is_smoking_detected?: boolean | undefined;
71633
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
71634
+ named_sensors?: {
71635
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
71636
+ sensor_name: string;
71637
+ /** Display name of the sensor. Defaults to `sensor_name`. */
71638
+ display_name: string;
71639
+ /** Temperature in °C, if the device measures temperature. */
71640
+ temperature_celsius?: number | undefined;
71641
+ /** Temperature in °F, if the device measures temperature. */
71642
+ temperature_fahrenheit?: number | undefined;
71643
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
71644
+ relative_humidity?: number | undefined;
71645
+ /** Noise level in decibels, if the device measures noise. */
71646
+ noise_level_decibels?: number | undefined;
71647
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
71648
+ noise_level_nrs?: number | undefined;
71649
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
71650
+ co2_ppm?: number | undefined;
71651
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
71652
+ co_ppm?: number | undefined;
71653
+ /** Air quality index, if the device measures it. */
71654
+ air_quality_index?: number | undefined;
71655
+ /** Mold risk level as reported by the device, if the device measures it. */
71656
+ mold_risk_level?: string | undefined;
71657
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
71658
+ is_occupied?: boolean | undefined;
71659
+ /** Number of occupants the device detects, if the device counts occupants. */
71660
+ occupant_count?: number | undefined;
71661
+ /** Indicates whether the device detects smoking, if the device measures it. */
71662
+ is_smoking_detected?: boolean | undefined;
71663
+ }[] | undefined;
71598
71664
  /** Indicates whether the device supports remote unlocking. */
71599
71665
  can_remotely_unlock?: boolean | undefined;
71600
71666
  /** Indicates whether the device supports remote locking. */
@@ -80631,56 +80697,9 @@ export type Routes = {
80631
80697
  * @deprecated use offline_access_codes_enabled*/
80632
80698
  supports_offline_access_codes?: boolean | undefined;
80633
80699
  /** Indicates current noise level in decibels, if the device supports noise detection. */
80634
- noise_level_decibels?: (number | null) | undefined;
80700
+ noise_level_decibels?: number | undefined;
80635
80701
  /** Array of noise threshold IDs that are currently triggering. */
80636
80702
  currently_triggering_noise_threshold_ids?: string[] | undefined;
80637
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
80638
- noise_level_nrs?: (number | null) | undefined;
80639
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
80640
- co2_ppm?: (number | null) | undefined;
80641
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
80642
- co_ppm?: (number | null) | undefined;
80643
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
80644
- air_quality_index?: (number | null) | undefined;
80645
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
80646
- mold_risk_level?: (string | null) | undefined;
80647
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
80648
- is_occupied?: (boolean | null) | undefined;
80649
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
80650
- occupant_count?: (number | null) | undefined;
80651
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
80652
- is_smoking_detected?: (boolean | null) | undefined;
80653
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
80654
- named_sensors?: {
80655
- /** Stable, hardware-defined name of the sensor, such as a port number. */
80656
- sensor_name: string;
80657
- /** Display name of the sensor. Defaults to `sensor_name`. */
80658
- display_name: string;
80659
- /** Reported temperature in °C. `null` until the first value arrives. */
80660
- temperature_celsius?: (number | null) | undefined;
80661
- /** Reported temperature in °F. `null` until the first value arrives. */
80662
- temperature_fahrenheit?: (number | null) | undefined;
80663
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
80664
- relative_humidity?: (number | null) | undefined;
80665
- /** Noise level in decibels. `null` until the first value arrives. */
80666
- noise_level_decibels?: (number | null) | undefined;
80667
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
80668
- noise_level_nrs?: (number | null) | undefined;
80669
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
80670
- co2_ppm?: (number | null) | undefined;
80671
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
80672
- co_ppm?: (number | null) | undefined;
80673
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
80674
- air_quality_index?: (number | null) | undefined;
80675
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
80676
- mold_risk_level?: (string | null) | undefined;
80677
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
80678
- is_occupied?: (boolean | null) | undefined;
80679
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
80680
- occupant_count?: (number | null) | undefined;
80681
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
80682
- is_smoking_detected?: (boolean | null) | undefined;
80683
- }[] | undefined;
80684
80703
  } & {
80685
80704
  /** ASSA ABLOY Credential Service metadata for the phone. */
80686
80705
  assa_abloy_credential_service_metadata?: ({
@@ -81525,11 +81544,11 @@ export type Routes = {
81525
81544
  } | undefined;
81526
81545
  } & {
81527
81546
  /** Reported temperature in °F. */
81528
- temperature_fahrenheit?: (number | null) | undefined;
81547
+ temperature_fahrenheit?: number | undefined;
81529
81548
  /** Reported temperature in °C. */
81530
- temperature_celsius?: (number | null) | undefined;
81549
+ temperature_celsius?: number | undefined;
81531
81550
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
81532
- relative_humidity?: (number | null) | undefined;
81551
+ relative_humidity?: number | undefined;
81533
81552
  /** HVAC mode settings that the thermostat supports. */
81534
81553
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
81535
81554
  /** Fan mode settings that the thermostat supports. */
@@ -82195,6 +82214,61 @@ export type Routes = {
82195
82214
  /** Image URL for the manufacturer logo. */
82196
82215
  image_url?: string | undefined;
82197
82216
  } | undefined;
82217
+ /** Temperature in °C, if the device measures temperature. */
82218
+ temperature_celsius?: number | undefined;
82219
+ /** Temperature in °F, if the device measures temperature. */
82220
+ temperature_fahrenheit?: number | undefined;
82221
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
82222
+ relative_humidity?: number | undefined;
82223
+ /** Noise level in decibels, if the device measures noise. */
82224
+ noise_level_decibels?: number | undefined;
82225
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
82226
+ noise_level_nrs?: number | undefined;
82227
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
82228
+ co2_ppm?: number | undefined;
82229
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
82230
+ co_ppm?: number | undefined;
82231
+ /** Air quality index, if the device measures it. */
82232
+ air_quality_index?: number | undefined;
82233
+ /** Mold risk level as reported by the device, if the device measures it. */
82234
+ mold_risk_level?: string | undefined;
82235
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
82236
+ is_occupied?: boolean | undefined;
82237
+ /** Number of occupants the device detects, if the device counts occupants. */
82238
+ occupant_count?: number | undefined;
82239
+ /** Indicates whether the device detects smoking, if the device measures it. */
82240
+ is_smoking_detected?: boolean | undefined;
82241
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
82242
+ named_sensors?: {
82243
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
82244
+ sensor_name: string;
82245
+ /** Display name of the sensor. Defaults to `sensor_name`. */
82246
+ display_name: string;
82247
+ /** Temperature in °C, if the device measures temperature. */
82248
+ temperature_celsius?: number | undefined;
82249
+ /** Temperature in °F, if the device measures temperature. */
82250
+ temperature_fahrenheit?: number | undefined;
82251
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
82252
+ relative_humidity?: number | undefined;
82253
+ /** Noise level in decibels, if the device measures noise. */
82254
+ noise_level_decibels?: number | undefined;
82255
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
82256
+ noise_level_nrs?: number | undefined;
82257
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
82258
+ co2_ppm?: number | undefined;
82259
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
82260
+ co_ppm?: number | undefined;
82261
+ /** Air quality index, if the device measures it. */
82262
+ air_quality_index?: number | undefined;
82263
+ /** Mold risk level as reported by the device, if the device measures it. */
82264
+ mold_risk_level?: string | undefined;
82265
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
82266
+ is_occupied?: boolean | undefined;
82267
+ /** Number of occupants the device detects, if the device counts occupants. */
82268
+ occupant_count?: number | undefined;
82269
+ /** Indicates whether the device detects smoking, if the device measures it. */
82270
+ is_smoking_detected?: boolean | undefined;
82271
+ }[] | undefined;
82198
82272
  /** Indicates whether the device supports remote unlocking. */
82199
82273
  can_remotely_unlock?: boolean | undefined;
82200
82274
  /** Indicates whether the device supports remote locking. */
@@ -82356,56 +82430,9 @@ export type Routes = {
82356
82430
  * @deprecated use offline_access_codes_enabled*/
82357
82431
  supports_offline_access_codes?: boolean | undefined;
82358
82432
  /** Indicates current noise level in decibels, if the device supports noise detection. */
82359
- noise_level_decibels?: (number | null) | undefined;
82433
+ noise_level_decibels?: number | undefined;
82360
82434
  /** Array of noise threshold IDs that are currently triggering. */
82361
82435
  currently_triggering_noise_threshold_ids?: string[] | undefined;
82362
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
82363
- noise_level_nrs?: (number | null) | undefined;
82364
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
82365
- co2_ppm?: (number | null) | undefined;
82366
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
82367
- co_ppm?: (number | null) | undefined;
82368
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
82369
- air_quality_index?: (number | null) | undefined;
82370
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
82371
- mold_risk_level?: (string | null) | undefined;
82372
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
82373
- is_occupied?: (boolean | null) | undefined;
82374
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
82375
- occupant_count?: (number | null) | undefined;
82376
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
82377
- is_smoking_detected?: (boolean | null) | undefined;
82378
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
82379
- named_sensors?: {
82380
- /** Stable, hardware-defined name of the sensor, such as a port number. */
82381
- sensor_name: string;
82382
- /** Display name of the sensor. Defaults to `sensor_name`. */
82383
- display_name: string;
82384
- /** Reported temperature in °C. `null` until the first value arrives. */
82385
- temperature_celsius?: (number | null) | undefined;
82386
- /** Reported temperature in °F. `null` until the first value arrives. */
82387
- temperature_fahrenheit?: (number | null) | undefined;
82388
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
82389
- relative_humidity?: (number | null) | undefined;
82390
- /** Noise level in decibels. `null` until the first value arrives. */
82391
- noise_level_decibels?: (number | null) | undefined;
82392
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
82393
- noise_level_nrs?: (number | null) | undefined;
82394
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
82395
- co2_ppm?: (number | null) | undefined;
82396
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
82397
- co_ppm?: (number | null) | undefined;
82398
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
82399
- air_quality_index?: (number | null) | undefined;
82400
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
82401
- mold_risk_level?: (string | null) | undefined;
82402
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
82403
- is_occupied?: (boolean | null) | undefined;
82404
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
82405
- occupant_count?: (number | null) | undefined;
82406
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
82407
- is_smoking_detected?: (boolean | null) | undefined;
82408
- }[] | undefined;
82409
82436
  } & {
82410
82437
  /** ASSA ABLOY Credential Service metadata for the phone. */
82411
82438
  assa_abloy_credential_service_metadata?: ({
@@ -83250,11 +83277,11 @@ export type Routes = {
83250
83277
  } | undefined;
83251
83278
  } & {
83252
83279
  /** Reported temperature in °F. */
83253
- temperature_fahrenheit?: (number | null) | undefined;
83280
+ temperature_fahrenheit?: number | undefined;
83254
83281
  /** Reported temperature in °C. */
83255
- temperature_celsius?: (number | null) | undefined;
83282
+ temperature_celsius?: number | undefined;
83256
83283
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
83257
- relative_humidity?: (number | null) | undefined;
83284
+ relative_humidity?: number | undefined;
83258
83285
  /** HVAC mode settings that the thermostat supports. */
83259
83286
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
83260
83287
  /** Fan mode settings that the thermostat supports. */
@@ -83920,6 +83947,61 @@ export type Routes = {
83920
83947
  /** Image URL for the manufacturer logo. */
83921
83948
  image_url?: string | undefined;
83922
83949
  } | undefined;
83950
+ /** Temperature in °C, if the device measures temperature. */
83951
+ temperature_celsius?: number | undefined;
83952
+ /** Temperature in °F, if the device measures temperature. */
83953
+ temperature_fahrenheit?: number | undefined;
83954
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
83955
+ relative_humidity?: number | undefined;
83956
+ /** Noise level in decibels, if the device measures noise. */
83957
+ noise_level_decibels?: number | undefined;
83958
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
83959
+ noise_level_nrs?: number | undefined;
83960
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
83961
+ co2_ppm?: number | undefined;
83962
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
83963
+ co_ppm?: number | undefined;
83964
+ /** Air quality index, if the device measures it. */
83965
+ air_quality_index?: number | undefined;
83966
+ /** Mold risk level as reported by the device, if the device measures it. */
83967
+ mold_risk_level?: string | undefined;
83968
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
83969
+ is_occupied?: boolean | undefined;
83970
+ /** Number of occupants the device detects, if the device counts occupants. */
83971
+ occupant_count?: number | undefined;
83972
+ /** Indicates whether the device detects smoking, if the device measures it. */
83973
+ is_smoking_detected?: boolean | undefined;
83974
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
83975
+ named_sensors?: {
83976
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
83977
+ sensor_name: string;
83978
+ /** Display name of the sensor. Defaults to `sensor_name`. */
83979
+ display_name: string;
83980
+ /** Temperature in °C, if the device measures temperature. */
83981
+ temperature_celsius?: number | undefined;
83982
+ /** Temperature in °F, if the device measures temperature. */
83983
+ temperature_fahrenheit?: number | undefined;
83984
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
83985
+ relative_humidity?: number | undefined;
83986
+ /** Noise level in decibels, if the device measures noise. */
83987
+ noise_level_decibels?: number | undefined;
83988
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
83989
+ noise_level_nrs?: number | undefined;
83990
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
83991
+ co2_ppm?: number | undefined;
83992
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
83993
+ co_ppm?: number | undefined;
83994
+ /** Air quality index, if the device measures it. */
83995
+ air_quality_index?: number | undefined;
83996
+ /** Mold risk level as reported by the device, if the device measures it. */
83997
+ mold_risk_level?: string | undefined;
83998
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
83999
+ is_occupied?: boolean | undefined;
84000
+ /** Number of occupants the device detects, if the device counts occupants. */
84001
+ occupant_count?: number | undefined;
84002
+ /** Indicates whether the device detects smoking, if the device measures it. */
84003
+ is_smoking_detected?: boolean | undefined;
84004
+ }[] | undefined;
83923
84005
  /** Indicates whether the device supports remote unlocking. */
83924
84006
  can_remotely_unlock?: boolean | undefined;
83925
84007
  /** Indicates whether the device supports remote locking. */
@@ -92429,6 +92511,21 @@ export type Routes = {
92429
92511
  };
92430
92512
  maxDuration: undefined;
92431
92513
  };
92514
+ '/seam/console/v1/connected_accounts/replace_bridge': {
92515
+ route: '/seam/console/v1/connected_accounts/replace_bridge';
92516
+ method: 'POST';
92517
+ queryParams: {};
92518
+ jsonBody: {
92519
+ /** ID of the connected account whose Seam Bridge you want to replace. */
92520
+ connected_account_id: string;
92521
+ /** Pairing code shown in the new Seam Bridge app. */
92522
+ pairing_code: string;
92523
+ };
92524
+ commonParams: {};
92525
+ formData: {};
92526
+ jsonResponse: {};
92527
+ maxDuration: undefined;
92528
+ };
92432
92529
  '/seam/console/v1/credits/checkout/start': {
92433
92530
  route: '/seam/console/v1/credits/checkout/start';
92434
92531
  method: 'POST';
@@ -93277,6 +93374,8 @@ export type Routes = {
93277
93374
  allow_instant_key_customization?: boolean | undefined;
93278
93375
  /** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
93279
93376
  allow_notification_customization?: boolean | undefined;
93377
+ /** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
93378
+ allow_bridge_replacement?: boolean | undefined;
93280
93379
  } | undefined;
93281
93380
  } | undefined;
93282
93381
  };
@@ -97134,6 +97233,21 @@ export type Routes = {
97134
97233
  jsonResponse: {};
97135
97234
  maxDuration: undefined;
97136
97235
  };
97236
+ '/seam/customer/v1/connected_accounts/replace_bridge': {
97237
+ route: '/seam/customer/v1/connected_accounts/replace_bridge';
97238
+ method: 'POST';
97239
+ queryParams: {};
97240
+ jsonBody: {
97241
+ /** ID of the connected account whose Seam Bridge you want to replace. */
97242
+ connected_account_id: string;
97243
+ /** Pairing code shown in the new Seam Bridge app. */
97244
+ pairing_code: string;
97245
+ };
97246
+ commonParams: {};
97247
+ formData: {};
97248
+ jsonResponse: {};
97249
+ maxDuration: undefined;
97250
+ };
97137
97251
  '/seam/customer/v1/connector_customers/list': {
97138
97252
  route: '/seam/customer/v1/connector_customers/list';
97139
97253
  method: 'GET' | 'POST';
@@ -101673,6 +101787,8 @@ export type Routes = {
101673
101787
  allow_instant_key_customization?: boolean;
101674
101788
  /** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
101675
101789
  allow_notification_customization?: boolean;
101790
+ /** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
101791
+ allow_bridge_replacement?: boolean;
101676
101792
  };
101677
101793
  };
101678
101794
  /** Whether the portal is embedded in another application. */
@@ -101896,6 +102012,8 @@ export type Routes = {
101896
102012
  allow_instant_key_customization?: boolean | undefined;
101897
102013
  /** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
101898
102014
  allow_notification_customization?: boolean | undefined;
102015
+ /** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
102016
+ allow_bridge_replacement?: boolean | undefined;
101899
102017
  } | undefined;
101900
102018
  } | undefined;
101901
102019
  };
@@ -107927,56 +108045,9 @@ export type Routes = {
107927
108045
  * @deprecated use offline_access_codes_enabled*/
107928
108046
  supports_offline_access_codes?: boolean | undefined;
107929
108047
  /** Indicates current noise level in decibels, if the device supports noise detection. */
107930
- noise_level_decibels?: (number | null) | undefined;
108048
+ noise_level_decibels?: number | undefined;
107931
108049
  /** Array of noise threshold IDs that are currently triggering. */
107932
108050
  currently_triggering_noise_threshold_ids?: string[] | undefined;
107933
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
107934
- noise_level_nrs?: (number | null) | undefined;
107935
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
107936
- co2_ppm?: (number | null) | undefined;
107937
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
107938
- co_ppm?: (number | null) | undefined;
107939
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
107940
- air_quality_index?: (number | null) | undefined;
107941
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
107942
- mold_risk_level?: (string | null) | undefined;
107943
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
107944
- is_occupied?: (boolean | null) | undefined;
107945
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
107946
- occupant_count?: (number | null) | undefined;
107947
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
107948
- is_smoking_detected?: (boolean | null) | undefined;
107949
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
107950
- named_sensors?: {
107951
- /** Stable, hardware-defined name of the sensor, such as a port number. */
107952
- sensor_name: string;
107953
- /** Display name of the sensor. Defaults to `sensor_name`. */
107954
- display_name: string;
107955
- /** Reported temperature in °C. `null` until the first value arrives. */
107956
- temperature_celsius?: (number | null) | undefined;
107957
- /** Reported temperature in °F. `null` until the first value arrives. */
107958
- temperature_fahrenheit?: (number | null) | undefined;
107959
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
107960
- relative_humidity?: (number | null) | undefined;
107961
- /** Noise level in decibels. `null` until the first value arrives. */
107962
- noise_level_decibels?: (number | null) | undefined;
107963
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
107964
- noise_level_nrs?: (number | null) | undefined;
107965
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
107966
- co2_ppm?: (number | null) | undefined;
107967
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
107968
- co_ppm?: (number | null) | undefined;
107969
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
107970
- air_quality_index?: (number | null) | undefined;
107971
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
107972
- mold_risk_level?: (string | null) | undefined;
107973
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
107974
- is_occupied?: (boolean | null) | undefined;
107975
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
107976
- occupant_count?: (number | null) | undefined;
107977
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
107978
- is_smoking_detected?: (boolean | null) | undefined;
107979
- }[] | undefined;
107980
108051
  } & {
107981
108052
  /** ASSA ABLOY Credential Service metadata for the phone. */
107982
108053
  assa_abloy_credential_service_metadata?: ({
@@ -108821,11 +108892,11 @@ export type Routes = {
108821
108892
  } | undefined;
108822
108893
  } & {
108823
108894
  /** Reported temperature in °F. */
108824
- temperature_fahrenheit?: (number | null) | undefined;
108895
+ temperature_fahrenheit?: number | undefined;
108825
108896
  /** Reported temperature in °C. */
108826
- temperature_celsius?: (number | null) | undefined;
108897
+ temperature_celsius?: number | undefined;
108827
108898
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
108828
- relative_humidity?: (number | null) | undefined;
108899
+ relative_humidity?: number | undefined;
108829
108900
  /** HVAC mode settings that the thermostat supports. */
108830
108901
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
108831
108902
  /** Fan mode settings that the thermostat supports. */
@@ -109491,6 +109562,61 @@ export type Routes = {
109491
109562
  /** Image URL for the manufacturer logo. */
109492
109563
  image_url?: string | undefined;
109493
109564
  } | undefined;
109565
+ /** Temperature in °C, if the device measures temperature. */
109566
+ temperature_celsius?: number | undefined;
109567
+ /** Temperature in °F, if the device measures temperature. */
109568
+ temperature_fahrenheit?: number | undefined;
109569
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
109570
+ relative_humidity?: number | undefined;
109571
+ /** Noise level in decibels, if the device measures noise. */
109572
+ noise_level_decibels?: number | undefined;
109573
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
109574
+ noise_level_nrs?: number | undefined;
109575
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
109576
+ co2_ppm?: number | undefined;
109577
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
109578
+ co_ppm?: number | undefined;
109579
+ /** Air quality index, if the device measures it. */
109580
+ air_quality_index?: number | undefined;
109581
+ /** Mold risk level as reported by the device, if the device measures it. */
109582
+ mold_risk_level?: string | undefined;
109583
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
109584
+ is_occupied?: boolean | undefined;
109585
+ /** Number of occupants the device detects, if the device counts occupants. */
109586
+ occupant_count?: number | undefined;
109587
+ /** Indicates whether the device detects smoking, if the device measures it. */
109588
+ is_smoking_detected?: boolean | undefined;
109589
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
109590
+ named_sensors?: {
109591
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
109592
+ sensor_name: string;
109593
+ /** Display name of the sensor. Defaults to `sensor_name`. */
109594
+ display_name: string;
109595
+ /** Temperature in °C, if the device measures temperature. */
109596
+ temperature_celsius?: number | undefined;
109597
+ /** Temperature in °F, if the device measures temperature. */
109598
+ temperature_fahrenheit?: number | undefined;
109599
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
109600
+ relative_humidity?: number | undefined;
109601
+ /** Noise level in decibels, if the device measures noise. */
109602
+ noise_level_decibels?: number | undefined;
109603
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
109604
+ noise_level_nrs?: number | undefined;
109605
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
109606
+ co2_ppm?: number | undefined;
109607
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
109608
+ co_ppm?: number | undefined;
109609
+ /** Air quality index, if the device measures it. */
109610
+ air_quality_index?: number | undefined;
109611
+ /** Mold risk level as reported by the device, if the device measures it. */
109612
+ mold_risk_level?: string | undefined;
109613
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
109614
+ is_occupied?: boolean | undefined;
109615
+ /** Number of occupants the device detects, if the device counts occupants. */
109616
+ occupant_count?: number | undefined;
109617
+ /** Indicates whether the device detects smoking, if the device measures it. */
109618
+ is_smoking_detected?: boolean | undefined;
109619
+ }[] | undefined;
109494
109620
  /** Indicates whether the device supports remote unlocking. */
109495
109621
  can_remotely_unlock?: boolean | undefined;
109496
109622
  /** Indicates whether the device supports remote locking. */
@@ -137218,56 +137344,9 @@ export type Routes = {
137218
137344
  * @deprecated use offline_access_codes_enabled*/
137219
137345
  supports_offline_access_codes?: boolean | undefined;
137220
137346
  /** Indicates current noise level in decibels, if the device supports noise detection. */
137221
- noise_level_decibels?: (number | null) | undefined;
137347
+ noise_level_decibels?: number | undefined;
137222
137348
  /** Array of noise threshold IDs that are currently triggering. */
137223
137349
  currently_triggering_noise_threshold_ids?: string[] | undefined;
137224
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
137225
- noise_level_nrs?: (number | null) | undefined;
137226
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
137227
- co2_ppm?: (number | null) | undefined;
137228
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
137229
- co_ppm?: (number | null) | undefined;
137230
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
137231
- air_quality_index?: (number | null) | undefined;
137232
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
137233
- mold_risk_level?: (string | null) | undefined;
137234
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
137235
- is_occupied?: (boolean | null) | undefined;
137236
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
137237
- occupant_count?: (number | null) | undefined;
137238
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
137239
- is_smoking_detected?: (boolean | null) | undefined;
137240
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
137241
- named_sensors?: {
137242
- /** Stable, hardware-defined name of the sensor, such as a port number. */
137243
- sensor_name: string;
137244
- /** Display name of the sensor. Defaults to `sensor_name`. */
137245
- display_name: string;
137246
- /** Reported temperature in °C. `null` until the first value arrives. */
137247
- temperature_celsius?: (number | null) | undefined;
137248
- /** Reported temperature in °F. `null` until the first value arrives. */
137249
- temperature_fahrenheit?: (number | null) | undefined;
137250
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
137251
- relative_humidity?: (number | null) | undefined;
137252
- /** Noise level in decibels. `null` until the first value arrives. */
137253
- noise_level_decibels?: (number | null) | undefined;
137254
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
137255
- noise_level_nrs?: (number | null) | undefined;
137256
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
137257
- co2_ppm?: (number | null) | undefined;
137258
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
137259
- co_ppm?: (number | null) | undefined;
137260
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
137261
- air_quality_index?: (number | null) | undefined;
137262
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
137263
- mold_risk_level?: (string | null) | undefined;
137264
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
137265
- is_occupied?: (boolean | null) | undefined;
137266
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
137267
- occupant_count?: (number | null) | undefined;
137268
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
137269
- is_smoking_detected?: (boolean | null) | undefined;
137270
- }[] | undefined;
137271
137350
  } & {
137272
137351
  /** ASSA ABLOY Credential Service metadata for the phone. */
137273
137352
  assa_abloy_credential_service_metadata?: ({
@@ -138112,11 +138191,11 @@ export type Routes = {
138112
138191
  } | undefined;
138113
138192
  } & {
138114
138193
  /** Reported temperature in °F. */
138115
- temperature_fahrenheit?: (number | null) | undefined;
138194
+ temperature_fahrenheit?: number | undefined;
138116
138195
  /** Reported temperature in °C. */
138117
- temperature_celsius?: (number | null) | undefined;
138196
+ temperature_celsius?: number | undefined;
138118
138197
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
138119
- relative_humidity?: (number | null) | undefined;
138198
+ relative_humidity?: number | undefined;
138120
138199
  /** HVAC mode settings that the thermostat supports. */
138121
138200
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
138122
138201
  /** Fan mode settings that the thermostat supports. */
@@ -138782,6 +138861,61 @@ export type Routes = {
138782
138861
  /** Image URL for the manufacturer logo. */
138783
138862
  image_url?: string | undefined;
138784
138863
  } | undefined;
138864
+ /** Temperature in °C, if the device measures temperature. */
138865
+ temperature_celsius?: number | undefined;
138866
+ /** Temperature in °F, if the device measures temperature. */
138867
+ temperature_fahrenheit?: number | undefined;
138868
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
138869
+ relative_humidity?: number | undefined;
138870
+ /** Noise level in decibels, if the device measures noise. */
138871
+ noise_level_decibels?: number | undefined;
138872
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
138873
+ noise_level_nrs?: number | undefined;
138874
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
138875
+ co2_ppm?: number | undefined;
138876
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
138877
+ co_ppm?: number | undefined;
138878
+ /** Air quality index, if the device measures it. */
138879
+ air_quality_index?: number | undefined;
138880
+ /** Mold risk level as reported by the device, if the device measures it. */
138881
+ mold_risk_level?: string | undefined;
138882
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
138883
+ is_occupied?: boolean | undefined;
138884
+ /** Number of occupants the device detects, if the device counts occupants. */
138885
+ occupant_count?: number | undefined;
138886
+ /** Indicates whether the device detects smoking, if the device measures it. */
138887
+ is_smoking_detected?: boolean | undefined;
138888
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
138889
+ named_sensors?: {
138890
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
138891
+ sensor_name: string;
138892
+ /** Display name of the sensor. Defaults to `sensor_name`. */
138893
+ display_name: string;
138894
+ /** Temperature in °C, if the device measures temperature. */
138895
+ temperature_celsius?: number | undefined;
138896
+ /** Temperature in °F, if the device measures temperature. */
138897
+ temperature_fahrenheit?: number | undefined;
138898
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
138899
+ relative_humidity?: number | undefined;
138900
+ /** Noise level in decibels, if the device measures noise. */
138901
+ noise_level_decibels?: number | undefined;
138902
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
138903
+ noise_level_nrs?: number | undefined;
138904
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
138905
+ co2_ppm?: number | undefined;
138906
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
138907
+ co_ppm?: number | undefined;
138908
+ /** Air quality index, if the device measures it. */
138909
+ air_quality_index?: number | undefined;
138910
+ /** Mold risk level as reported by the device, if the device measures it. */
138911
+ mold_risk_level?: string | undefined;
138912
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
138913
+ is_occupied?: boolean | undefined;
138914
+ /** Number of occupants the device detects, if the device counts occupants. */
138915
+ occupant_count?: number | undefined;
138916
+ /** Indicates whether the device detects smoking, if the device measures it. */
138917
+ is_smoking_detected?: boolean | undefined;
138918
+ }[] | undefined;
138785
138919
  /** Indicates whether the device supports remote unlocking. */
138786
138920
  can_remotely_unlock?: boolean | undefined;
138787
138921
  /** Indicates whether the device supports remote locking. */
@@ -143385,56 +143519,9 @@ export type Routes = {
143385
143519
  * @deprecated use offline_access_codes_enabled*/
143386
143520
  supports_offline_access_codes?: boolean | undefined;
143387
143521
  /** Indicates current noise level in decibels, if the device supports noise detection. */
143388
- noise_level_decibels?: (number | null) | undefined;
143522
+ noise_level_decibels?: number | undefined;
143389
143523
  /** Array of noise threshold IDs that are currently triggering. */
143390
143524
  currently_triggering_noise_threshold_ids?: string[] | undefined;
143391
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
143392
- noise_level_nrs?: (number | null) | undefined;
143393
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
143394
- co2_ppm?: (number | null) | undefined;
143395
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
143396
- co_ppm?: (number | null) | undefined;
143397
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
143398
- air_quality_index?: (number | null) | undefined;
143399
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
143400
- mold_risk_level?: (string | null) | undefined;
143401
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
143402
- is_occupied?: (boolean | null) | undefined;
143403
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
143404
- occupant_count?: (number | null) | undefined;
143405
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
143406
- is_smoking_detected?: (boolean | null) | undefined;
143407
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
143408
- named_sensors?: {
143409
- /** Stable, hardware-defined name of the sensor, such as a port number. */
143410
- sensor_name: string;
143411
- /** Display name of the sensor. Defaults to `sensor_name`. */
143412
- display_name: string;
143413
- /** Reported temperature in °C. `null` until the first value arrives. */
143414
- temperature_celsius?: (number | null) | undefined;
143415
- /** Reported temperature in °F. `null` until the first value arrives. */
143416
- temperature_fahrenheit?: (number | null) | undefined;
143417
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
143418
- relative_humidity?: (number | null) | undefined;
143419
- /** Noise level in decibels. `null` until the first value arrives. */
143420
- noise_level_decibels?: (number | null) | undefined;
143421
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
143422
- noise_level_nrs?: (number | null) | undefined;
143423
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
143424
- co2_ppm?: (number | null) | undefined;
143425
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
143426
- co_ppm?: (number | null) | undefined;
143427
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
143428
- air_quality_index?: (number | null) | undefined;
143429
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
143430
- mold_risk_level?: (string | null) | undefined;
143431
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
143432
- is_occupied?: (boolean | null) | undefined;
143433
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
143434
- occupant_count?: (number | null) | undefined;
143435
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
143436
- is_smoking_detected?: (boolean | null) | undefined;
143437
- }[] | undefined;
143438
143525
  } & {
143439
143526
  /** ASSA ABLOY Credential Service metadata for the phone. */
143440
143527
  assa_abloy_credential_service_metadata?: ({
@@ -144279,11 +144366,11 @@ export type Routes = {
144279
144366
  } | undefined;
144280
144367
  } & {
144281
144368
  /** Reported temperature in °F. */
144282
- temperature_fahrenheit?: (number | null) | undefined;
144369
+ temperature_fahrenheit?: number | undefined;
144283
144370
  /** Reported temperature in °C. */
144284
- temperature_celsius?: (number | null) | undefined;
144371
+ temperature_celsius?: number | undefined;
144285
144372
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
144286
- relative_humidity?: (number | null) | undefined;
144373
+ relative_humidity?: number | undefined;
144287
144374
  /** HVAC mode settings that the thermostat supports. */
144288
144375
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
144289
144376
  /** Fan mode settings that the thermostat supports. */
@@ -144949,6 +145036,61 @@ export type Routes = {
144949
145036
  /** Image URL for the manufacturer logo. */
144950
145037
  image_url?: string | undefined;
144951
145038
  } | undefined;
145039
+ /** Temperature in °C, if the device measures temperature. */
145040
+ temperature_celsius?: number | undefined;
145041
+ /** Temperature in °F, if the device measures temperature. */
145042
+ temperature_fahrenheit?: number | undefined;
145043
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
145044
+ relative_humidity?: number | undefined;
145045
+ /** Noise level in decibels, if the device measures noise. */
145046
+ noise_level_decibels?: number | undefined;
145047
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
145048
+ noise_level_nrs?: number | undefined;
145049
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
145050
+ co2_ppm?: number | undefined;
145051
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
145052
+ co_ppm?: number | undefined;
145053
+ /** Air quality index, if the device measures it. */
145054
+ air_quality_index?: number | undefined;
145055
+ /** Mold risk level as reported by the device, if the device measures it. */
145056
+ mold_risk_level?: string | undefined;
145057
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
145058
+ is_occupied?: boolean | undefined;
145059
+ /** Number of occupants the device detects, if the device counts occupants. */
145060
+ occupant_count?: number | undefined;
145061
+ /** Indicates whether the device detects smoking, if the device measures it. */
145062
+ is_smoking_detected?: boolean | undefined;
145063
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
145064
+ named_sensors?: {
145065
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
145066
+ sensor_name: string;
145067
+ /** Display name of the sensor. Defaults to `sensor_name`. */
145068
+ display_name: string;
145069
+ /** Temperature in °C, if the device measures temperature. */
145070
+ temperature_celsius?: number | undefined;
145071
+ /** Temperature in °F, if the device measures temperature. */
145072
+ temperature_fahrenheit?: number | undefined;
145073
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
145074
+ relative_humidity?: number | undefined;
145075
+ /** Noise level in decibels, if the device measures noise. */
145076
+ noise_level_decibels?: number | undefined;
145077
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
145078
+ noise_level_nrs?: number | undefined;
145079
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
145080
+ co2_ppm?: number | undefined;
145081
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
145082
+ co_ppm?: number | undefined;
145083
+ /** Air quality index, if the device measures it. */
145084
+ air_quality_index?: number | undefined;
145085
+ /** Mold risk level as reported by the device, if the device measures it. */
145086
+ mold_risk_level?: string | undefined;
145087
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
145088
+ is_occupied?: boolean | undefined;
145089
+ /** Number of occupants the device detects, if the device counts occupants. */
145090
+ occupant_count?: number | undefined;
145091
+ /** Indicates whether the device detects smoking, if the device measures it. */
145092
+ is_smoking_detected?: boolean | undefined;
145093
+ }[] | undefined;
144952
145094
  /** Indicates whether the device supports remote unlocking. */
144953
145095
  can_remotely_unlock?: boolean | undefined;
144954
145096
  /** Indicates whether the device supports remote locking. */
@@ -145110,56 +145252,9 @@ export type Routes = {
145110
145252
  * @deprecated use offline_access_codes_enabled*/
145111
145253
  supports_offline_access_codes?: boolean | undefined;
145112
145254
  /** Indicates current noise level in decibels, if the device supports noise detection. */
145113
- noise_level_decibels?: (number | null) | undefined;
145255
+ noise_level_decibels?: number | undefined;
145114
145256
  /** Array of noise threshold IDs that are currently triggering. */
145115
145257
  currently_triggering_noise_threshold_ids?: string[] | undefined;
145116
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
145117
- noise_level_nrs?: (number | null) | undefined;
145118
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
145119
- co2_ppm?: (number | null) | undefined;
145120
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
145121
- co_ppm?: (number | null) | undefined;
145122
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
145123
- air_quality_index?: (number | null) | undefined;
145124
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
145125
- mold_risk_level?: (string | null) | undefined;
145126
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
145127
- is_occupied?: (boolean | null) | undefined;
145128
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
145129
- occupant_count?: (number | null) | undefined;
145130
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
145131
- is_smoking_detected?: (boolean | null) | undefined;
145132
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
145133
- named_sensors?: {
145134
- /** Stable, hardware-defined name of the sensor, such as a port number. */
145135
- sensor_name: string;
145136
- /** Display name of the sensor. Defaults to `sensor_name`. */
145137
- display_name: string;
145138
- /** Reported temperature in °C. `null` until the first value arrives. */
145139
- temperature_celsius?: (number | null) | undefined;
145140
- /** Reported temperature in °F. `null` until the first value arrives. */
145141
- temperature_fahrenheit?: (number | null) | undefined;
145142
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
145143
- relative_humidity?: (number | null) | undefined;
145144
- /** Noise level in decibels. `null` until the first value arrives. */
145145
- noise_level_decibels?: (number | null) | undefined;
145146
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
145147
- noise_level_nrs?: (number | null) | undefined;
145148
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
145149
- co2_ppm?: (number | null) | undefined;
145150
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
145151
- co_ppm?: (number | null) | undefined;
145152
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
145153
- air_quality_index?: (number | null) | undefined;
145154
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
145155
- mold_risk_level?: (string | null) | undefined;
145156
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
145157
- is_occupied?: (boolean | null) | undefined;
145158
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
145159
- occupant_count?: (number | null) | undefined;
145160
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
145161
- is_smoking_detected?: (boolean | null) | undefined;
145162
- }[] | undefined;
145163
145258
  } & {
145164
145259
  /** ASSA ABLOY Credential Service metadata for the phone. */
145165
145260
  assa_abloy_credential_service_metadata?: ({
@@ -146004,11 +146099,11 @@ export type Routes = {
146004
146099
  } | undefined;
146005
146100
  } & {
146006
146101
  /** Reported temperature in °F. */
146007
- temperature_fahrenheit?: (number | null) | undefined;
146102
+ temperature_fahrenheit?: number | undefined;
146008
146103
  /** Reported temperature in °C. */
146009
- temperature_celsius?: (number | null) | undefined;
146104
+ temperature_celsius?: number | undefined;
146010
146105
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
146011
- relative_humidity?: (number | null) | undefined;
146106
+ relative_humidity?: number | undefined;
146012
146107
  /** HVAC mode settings that the thermostat supports. */
146013
146108
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
146014
146109
  /** Fan mode settings that the thermostat supports. */
@@ -146674,6 +146769,61 @@ export type Routes = {
146674
146769
  /** Image URL for the manufacturer logo. */
146675
146770
  image_url?: string | undefined;
146676
146771
  } | undefined;
146772
+ /** Temperature in °C, if the device measures temperature. */
146773
+ temperature_celsius?: number | undefined;
146774
+ /** Temperature in °F, if the device measures temperature. */
146775
+ temperature_fahrenheit?: number | undefined;
146776
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
146777
+ relative_humidity?: number | undefined;
146778
+ /** Noise level in decibels, if the device measures noise. */
146779
+ noise_level_decibels?: number | undefined;
146780
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
146781
+ noise_level_nrs?: number | undefined;
146782
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
146783
+ co2_ppm?: number | undefined;
146784
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
146785
+ co_ppm?: number | undefined;
146786
+ /** Air quality index, if the device measures it. */
146787
+ air_quality_index?: number | undefined;
146788
+ /** Mold risk level as reported by the device, if the device measures it. */
146789
+ mold_risk_level?: string | undefined;
146790
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
146791
+ is_occupied?: boolean | undefined;
146792
+ /** Number of occupants the device detects, if the device counts occupants. */
146793
+ occupant_count?: number | undefined;
146794
+ /** Indicates whether the device detects smoking, if the device measures it. */
146795
+ is_smoking_detected?: boolean | undefined;
146796
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
146797
+ named_sensors?: {
146798
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
146799
+ sensor_name: string;
146800
+ /** Display name of the sensor. Defaults to `sensor_name`. */
146801
+ display_name: string;
146802
+ /** Temperature in °C, if the device measures temperature. */
146803
+ temperature_celsius?: number | undefined;
146804
+ /** Temperature in °F, if the device measures temperature. */
146805
+ temperature_fahrenheit?: number | undefined;
146806
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
146807
+ relative_humidity?: number | undefined;
146808
+ /** Noise level in decibels, if the device measures noise. */
146809
+ noise_level_decibels?: number | undefined;
146810
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
146811
+ noise_level_nrs?: number | undefined;
146812
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
146813
+ co2_ppm?: number | undefined;
146814
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
146815
+ co_ppm?: number | undefined;
146816
+ /** Air quality index, if the device measures it. */
146817
+ air_quality_index?: number | undefined;
146818
+ /** Mold risk level as reported by the device, if the device measures it. */
146819
+ mold_risk_level?: string | undefined;
146820
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
146821
+ is_occupied?: boolean | undefined;
146822
+ /** Number of occupants the device detects, if the device counts occupants. */
146823
+ occupant_count?: number | undefined;
146824
+ /** Indicates whether the device detects smoking, if the device measures it. */
146825
+ is_smoking_detected?: boolean | undefined;
146826
+ }[] | undefined;
146677
146827
  /** Indicates whether the device supports remote unlocking. */
146678
146828
  can_remotely_unlock?: boolean | undefined;
146679
146829
  /** Indicates whether the device supports remote locking. */
@@ -156780,56 +156930,9 @@ export type Routes = {
156780
156930
  * @deprecated use offline_access_codes_enabled*/
156781
156931
  supports_offline_access_codes?: boolean | undefined;
156782
156932
  /** Indicates current noise level in decibels, if the device supports noise detection. */
156783
- noise_level_decibels?: (number | null) | undefined;
156933
+ noise_level_decibels?: number | undefined;
156784
156934
  /** Array of noise threshold IDs that are currently triggering. */
156785
156935
  currently_triggering_noise_threshold_ids?: string[] | undefined;
156786
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
156787
- noise_level_nrs?: (number | null) | undefined;
156788
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
156789
- co2_ppm?: (number | null) | undefined;
156790
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
156791
- co_ppm?: (number | null) | undefined;
156792
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
156793
- air_quality_index?: (number | null) | undefined;
156794
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
156795
- mold_risk_level?: (string | null) | undefined;
156796
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
156797
- is_occupied?: (boolean | null) | undefined;
156798
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
156799
- occupant_count?: (number | null) | undefined;
156800
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
156801
- is_smoking_detected?: (boolean | null) | undefined;
156802
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
156803
- named_sensors?: {
156804
- /** Stable, hardware-defined name of the sensor, such as a port number. */
156805
- sensor_name: string;
156806
- /** Display name of the sensor. Defaults to `sensor_name`. */
156807
- display_name: string;
156808
- /** Reported temperature in °C. `null` until the first value arrives. */
156809
- temperature_celsius?: (number | null) | undefined;
156810
- /** Reported temperature in °F. `null` until the first value arrives. */
156811
- temperature_fahrenheit?: (number | null) | undefined;
156812
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
156813
- relative_humidity?: (number | null) | undefined;
156814
- /** Noise level in decibels. `null` until the first value arrives. */
156815
- noise_level_decibels?: (number | null) | undefined;
156816
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
156817
- noise_level_nrs?: (number | null) | undefined;
156818
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
156819
- co2_ppm?: (number | null) | undefined;
156820
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
156821
- co_ppm?: (number | null) | undefined;
156822
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
156823
- air_quality_index?: (number | null) | undefined;
156824
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
156825
- mold_risk_level?: (string | null) | undefined;
156826
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
156827
- is_occupied?: (boolean | null) | undefined;
156828
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
156829
- occupant_count?: (number | null) | undefined;
156830
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
156831
- is_smoking_detected?: (boolean | null) | undefined;
156832
- }[] | undefined;
156833
156936
  } & {
156834
156937
  /** ASSA ABLOY Credential Service metadata for the phone. */
156835
156938
  assa_abloy_credential_service_metadata?: ({
@@ -157674,11 +157777,11 @@ export type Routes = {
157674
157777
  } | undefined;
157675
157778
  } & {
157676
157779
  /** Reported temperature in °F. */
157677
- temperature_fahrenheit?: (number | null) | undefined;
157780
+ temperature_fahrenheit?: number | undefined;
157678
157781
  /** Reported temperature in °C. */
157679
- temperature_celsius?: (number | null) | undefined;
157782
+ temperature_celsius?: number | undefined;
157680
157783
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
157681
- relative_humidity?: (number | null) | undefined;
157784
+ relative_humidity?: number | undefined;
157682
157785
  /** HVAC mode settings that the thermostat supports. */
157683
157786
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
157684
157787
  /** Fan mode settings that the thermostat supports. */
@@ -158344,6 +158447,61 @@ export type Routes = {
158344
158447
  /** Image URL for the manufacturer logo. */
158345
158448
  image_url?: string | undefined;
158346
158449
  } | undefined;
158450
+ /** Temperature in °C, if the device measures temperature. */
158451
+ temperature_celsius?: number | undefined;
158452
+ /** Temperature in °F, if the device measures temperature. */
158453
+ temperature_fahrenheit?: number | undefined;
158454
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
158455
+ relative_humidity?: number | undefined;
158456
+ /** Noise level in decibels, if the device measures noise. */
158457
+ noise_level_decibels?: number | undefined;
158458
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
158459
+ noise_level_nrs?: number | undefined;
158460
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
158461
+ co2_ppm?: number | undefined;
158462
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
158463
+ co_ppm?: number | undefined;
158464
+ /** Air quality index, if the device measures it. */
158465
+ air_quality_index?: number | undefined;
158466
+ /** Mold risk level as reported by the device, if the device measures it. */
158467
+ mold_risk_level?: string | undefined;
158468
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
158469
+ is_occupied?: boolean | undefined;
158470
+ /** Number of occupants the device detects, if the device counts occupants. */
158471
+ occupant_count?: number | undefined;
158472
+ /** Indicates whether the device detects smoking, if the device measures it. */
158473
+ is_smoking_detected?: boolean | undefined;
158474
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
158475
+ named_sensors?: {
158476
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
158477
+ sensor_name: string;
158478
+ /** Display name of the sensor. Defaults to `sensor_name`. */
158479
+ display_name: string;
158480
+ /** Temperature in °C, if the device measures temperature. */
158481
+ temperature_celsius?: number | undefined;
158482
+ /** Temperature in °F, if the device measures temperature. */
158483
+ temperature_fahrenheit?: number | undefined;
158484
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
158485
+ relative_humidity?: number | undefined;
158486
+ /** Noise level in decibels, if the device measures noise. */
158487
+ noise_level_decibels?: number | undefined;
158488
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
158489
+ noise_level_nrs?: number | undefined;
158490
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
158491
+ co2_ppm?: number | undefined;
158492
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
158493
+ co_ppm?: number | undefined;
158494
+ /** Air quality index, if the device measures it. */
158495
+ air_quality_index?: number | undefined;
158496
+ /** Mold risk level as reported by the device, if the device measures it. */
158497
+ mold_risk_level?: string | undefined;
158498
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
158499
+ is_occupied?: boolean | undefined;
158500
+ /** Number of occupants the device detects, if the device counts occupants. */
158501
+ occupant_count?: number | undefined;
158502
+ /** Indicates whether the device detects smoking, if the device measures it. */
158503
+ is_smoking_detected?: boolean | undefined;
158504
+ }[] | undefined;
158347
158505
  /** Indicates whether the device supports remote unlocking. */
158348
158506
  can_remotely_unlock?: boolean | undefined;
158349
158507
  /** Indicates whether the device supports remote locking. */
@@ -158507,56 +158665,9 @@ export type Routes = {
158507
158665
  * @deprecated use offline_access_codes_enabled*/
158508
158666
  supports_offline_access_codes?: boolean | undefined;
158509
158667
  /** Indicates current noise level in decibels, if the device supports noise detection. */
158510
- noise_level_decibels?: (number | null) | undefined;
158668
+ noise_level_decibels?: number | undefined;
158511
158669
  /** Array of noise threshold IDs that are currently triggering. */
158512
158670
  currently_triggering_noise_threshold_ids?: string[] | undefined;
158513
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
158514
- noise_level_nrs?: (number | null) | undefined;
158515
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
158516
- co2_ppm?: (number | null) | undefined;
158517
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
158518
- co_ppm?: (number | null) | undefined;
158519
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
158520
- air_quality_index?: (number | null) | undefined;
158521
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
158522
- mold_risk_level?: (string | null) | undefined;
158523
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
158524
- is_occupied?: (boolean | null) | undefined;
158525
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
158526
- occupant_count?: (number | null) | undefined;
158527
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
158528
- is_smoking_detected?: (boolean | null) | undefined;
158529
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
158530
- named_sensors?: {
158531
- /** Stable, hardware-defined name of the sensor, such as a port number. */
158532
- sensor_name: string;
158533
- /** Display name of the sensor. Defaults to `sensor_name`. */
158534
- display_name: string;
158535
- /** Reported temperature in °C. `null` until the first value arrives. */
158536
- temperature_celsius?: (number | null) | undefined;
158537
- /** Reported temperature in °F. `null` until the first value arrives. */
158538
- temperature_fahrenheit?: (number | null) | undefined;
158539
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
158540
- relative_humidity?: (number | null) | undefined;
158541
- /** Noise level in decibels. `null` until the first value arrives. */
158542
- noise_level_decibels?: (number | null) | undefined;
158543
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
158544
- noise_level_nrs?: (number | null) | undefined;
158545
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
158546
- co2_ppm?: (number | null) | undefined;
158547
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
158548
- co_ppm?: (number | null) | undefined;
158549
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
158550
- air_quality_index?: (number | null) | undefined;
158551
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
158552
- mold_risk_level?: (string | null) | undefined;
158553
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
158554
- is_occupied?: (boolean | null) | undefined;
158555
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
158556
- occupant_count?: (number | null) | undefined;
158557
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
158558
- is_smoking_detected?: (boolean | null) | undefined;
158559
- }[] | undefined;
158560
158671
  } & {
158561
158672
  /** ASSA ABLOY Credential Service metadata for the phone. */
158562
158673
  assa_abloy_credential_service_metadata?: ({
@@ -159401,11 +159512,11 @@ export type Routes = {
159401
159512
  } | undefined;
159402
159513
  } & {
159403
159514
  /** Reported temperature in °F. */
159404
- temperature_fahrenheit?: (number | null) | undefined;
159515
+ temperature_fahrenheit?: number | undefined;
159405
159516
  /** Reported temperature in °C. */
159406
- temperature_celsius?: (number | null) | undefined;
159517
+ temperature_celsius?: number | undefined;
159407
159518
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
159408
- relative_humidity?: (number | null) | undefined;
159519
+ relative_humidity?: number | undefined;
159409
159520
  /** HVAC mode settings that the thermostat supports. */
159410
159521
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
159411
159522
  /** Fan mode settings that the thermostat supports. */
@@ -160071,6 +160182,61 @@ export type Routes = {
160071
160182
  /** Image URL for the manufacturer logo. */
160072
160183
  image_url?: string | undefined;
160073
160184
  } | undefined;
160185
+ /** Temperature in °C, if the device measures temperature. */
160186
+ temperature_celsius?: number | undefined;
160187
+ /** Temperature in °F, if the device measures temperature. */
160188
+ temperature_fahrenheit?: number | undefined;
160189
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
160190
+ relative_humidity?: number | undefined;
160191
+ /** Noise level in decibels, if the device measures noise. */
160192
+ noise_level_decibels?: number | undefined;
160193
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
160194
+ noise_level_nrs?: number | undefined;
160195
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
160196
+ co2_ppm?: number | undefined;
160197
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
160198
+ co_ppm?: number | undefined;
160199
+ /** Air quality index, if the device measures it. */
160200
+ air_quality_index?: number | undefined;
160201
+ /** Mold risk level as reported by the device, if the device measures it. */
160202
+ mold_risk_level?: string | undefined;
160203
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
160204
+ is_occupied?: boolean | undefined;
160205
+ /** Number of occupants the device detects, if the device counts occupants. */
160206
+ occupant_count?: number | undefined;
160207
+ /** Indicates whether the device detects smoking, if the device measures it. */
160208
+ is_smoking_detected?: boolean | undefined;
160209
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
160210
+ named_sensors?: {
160211
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
160212
+ sensor_name: string;
160213
+ /** Display name of the sensor. Defaults to `sensor_name`. */
160214
+ display_name: string;
160215
+ /** Temperature in °C, if the device measures temperature. */
160216
+ temperature_celsius?: number | undefined;
160217
+ /** Temperature in °F, if the device measures temperature. */
160218
+ temperature_fahrenheit?: number | undefined;
160219
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
160220
+ relative_humidity?: number | undefined;
160221
+ /** Noise level in decibels, if the device measures noise. */
160222
+ noise_level_decibels?: number | undefined;
160223
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
160224
+ noise_level_nrs?: number | undefined;
160225
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
160226
+ co2_ppm?: number | undefined;
160227
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
160228
+ co_ppm?: number | undefined;
160229
+ /** Air quality index, if the device measures it. */
160230
+ air_quality_index?: number | undefined;
160231
+ /** Mold risk level as reported by the device, if the device measures it. */
160232
+ mold_risk_level?: string | undefined;
160233
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
160234
+ is_occupied?: boolean | undefined;
160235
+ /** Number of occupants the device detects, if the device counts occupants. */
160236
+ occupant_count?: number | undefined;
160237
+ /** Indicates whether the device detects smoking, if the device measures it. */
160238
+ is_smoking_detected?: boolean | undefined;
160239
+ }[] | undefined;
160074
160240
  /** Indicates whether the device supports remote unlocking. */
160075
160241
  can_remotely_unlock?: boolean | undefined;
160076
160242
  /** Indicates whether the device supports remote locking. */
@@ -161436,6 +161602,8 @@ export type Routes = {
161436
161602
  allow_instant_key_customization?: boolean | undefined;
161437
161603
  /** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
161438
161604
  allow_notification_customization?: boolean | undefined;
161605
+ /** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
161606
+ allow_bridge_replacement?: boolean | undefined;
161439
161607
  } | undefined;
161440
161608
  } | undefined;
161441
161609
  };
@@ -161664,6 +161832,8 @@ export type Routes = {
161664
161832
  allow_instant_key_customization?: boolean | undefined;
161665
161833
  /** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
161666
161834
  allow_notification_customization?: boolean | undefined;
161835
+ /** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
161836
+ allow_bridge_replacement?: boolean | undefined;
161667
161837
  } | undefined;
161668
161838
  } | undefined;
161669
161839
  };
@@ -161902,6 +162072,8 @@ export type Routes = {
161902
162072
  allow_instant_key_customization?: boolean | undefined;
161903
162073
  /** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
161904
162074
  allow_notification_customization?: boolean | undefined;
162075
+ /** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
162076
+ allow_bridge_replacement?: boolean | undefined;
161905
162077
  } | undefined;
161906
162078
  } | undefined;
161907
162079
  };
@@ -162140,6 +162312,8 @@ export type Routes = {
162140
162312
  allow_instant_key_customization?: boolean | undefined;
162141
162313
  /** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
162142
162314
  allow_notification_customization?: boolean | undefined;
162315
+ /** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
162316
+ allow_bridge_replacement?: boolean | undefined;
162143
162317
  } | undefined;
162144
162318
  } | undefined;
162145
162319
  }[];
@@ -162363,6 +162537,8 @@ export type Routes = {
162363
162537
  allow_instant_key_customization?: boolean | undefined;
162364
162538
  /** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
162365
162539
  allow_notification_customization?: boolean | undefined;
162540
+ /** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
162541
+ allow_bridge_replacement?: boolean | undefined;
162366
162542
  } | undefined;
162367
162543
  } | undefined) | null;
162368
162544
  is_workspace_default?: boolean | undefined;
@@ -162580,56 +162756,9 @@ export type Routes = {
162580
162756
  * @deprecated use offline_access_codes_enabled*/
162581
162757
  supports_offline_access_codes?: boolean | undefined;
162582
162758
  /** Indicates current noise level in decibels, if the device supports noise detection. */
162583
- noise_level_decibels?: (number | null) | undefined;
162759
+ noise_level_decibels?: number | undefined;
162584
162760
  /** Array of noise threshold IDs that are currently triggering. */
162585
162761
  currently_triggering_noise_threshold_ids?: string[] | undefined;
162586
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
162587
- noise_level_nrs?: (number | null) | undefined;
162588
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
162589
- co2_ppm?: (number | null) | undefined;
162590
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
162591
- co_ppm?: (number | null) | undefined;
162592
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
162593
- air_quality_index?: (number | null) | undefined;
162594
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
162595
- mold_risk_level?: (string | null) | undefined;
162596
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
162597
- is_occupied?: (boolean | null) | undefined;
162598
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
162599
- occupant_count?: (number | null) | undefined;
162600
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
162601
- is_smoking_detected?: (boolean | null) | undefined;
162602
- /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
162603
- named_sensors?: {
162604
- /** Stable, hardware-defined name of the sensor, such as a port number. */
162605
- sensor_name: string;
162606
- /** Display name of the sensor. Defaults to `sensor_name`. */
162607
- display_name: string;
162608
- /** Reported temperature in °C. `null` until the first value arrives. */
162609
- temperature_celsius?: (number | null) | undefined;
162610
- /** Reported temperature in °F. `null` until the first value arrives. */
162611
- temperature_fahrenheit?: (number | null) | undefined;
162612
- /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
162613
- relative_humidity?: (number | null) | undefined;
162614
- /** Noise level in decibels. `null` until the first value arrives. */
162615
- noise_level_decibels?: (number | null) | undefined;
162616
- /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
162617
- noise_level_nrs?: (number | null) | undefined;
162618
- /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
162619
- co2_ppm?: (number | null) | undefined;
162620
- /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
162621
- co_ppm?: (number | null) | undefined;
162622
- /** Air quality index, if the device measures it. `null` until the first value arrives. */
162623
- air_quality_index?: (number | null) | undefined;
162624
- /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
162625
- mold_risk_level?: (string | null) | undefined;
162626
- /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
162627
- is_occupied?: (boolean | null) | undefined;
162628
- /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
162629
- occupant_count?: (number | null) | undefined;
162630
- /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
162631
- is_smoking_detected?: (boolean | null) | undefined;
162632
- }[] | undefined;
162633
162762
  } & {
162634
162763
  /** ASSA ABLOY Credential Service metadata for the phone. */
162635
162764
  assa_abloy_credential_service_metadata?: ({
@@ -163474,11 +163603,11 @@ export type Routes = {
163474
163603
  } | undefined;
163475
163604
  } & {
163476
163605
  /** Reported temperature in °F. */
163477
- temperature_fahrenheit?: (number | null) | undefined;
163606
+ temperature_fahrenheit?: number | undefined;
163478
163607
  /** Reported temperature in °C. */
163479
- temperature_celsius?: (number | null) | undefined;
163608
+ temperature_celsius?: number | undefined;
163480
163609
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
163481
- relative_humidity?: (number | null) | undefined;
163610
+ relative_humidity?: number | undefined;
163482
163611
  /** HVAC mode settings that the thermostat supports. */
163483
163612
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
163484
163613
  /** Fan mode settings that the thermostat supports. */
@@ -164144,6 +164273,61 @@ export type Routes = {
164144
164273
  /** Image URL for the manufacturer logo. */
164145
164274
  image_url?: string | undefined;
164146
164275
  } | undefined;
164276
+ /** Temperature in °C, if the device measures temperature. */
164277
+ temperature_celsius?: number | undefined;
164278
+ /** Temperature in °F, if the device measures temperature. */
164279
+ temperature_fahrenheit?: number | undefined;
164280
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
164281
+ relative_humidity?: number | undefined;
164282
+ /** Noise level in decibels, if the device measures noise. */
164283
+ noise_level_decibels?: number | undefined;
164284
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
164285
+ noise_level_nrs?: number | undefined;
164286
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
164287
+ co2_ppm?: number | undefined;
164288
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
164289
+ co_ppm?: number | undefined;
164290
+ /** Air quality index, if the device measures it. */
164291
+ air_quality_index?: number | undefined;
164292
+ /** Mold risk level as reported by the device, if the device measures it. */
164293
+ mold_risk_level?: string | undefined;
164294
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
164295
+ is_occupied?: boolean | undefined;
164296
+ /** Number of occupants the device detects, if the device counts occupants. */
164297
+ occupant_count?: number | undefined;
164298
+ /** Indicates whether the device detects smoking, if the device measures it. */
164299
+ is_smoking_detected?: boolean | undefined;
164300
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
164301
+ named_sensors?: {
164302
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
164303
+ sensor_name: string;
164304
+ /** Display name of the sensor. Defaults to `sensor_name`. */
164305
+ display_name: string;
164306
+ /** Temperature in °C, if the device measures temperature. */
164307
+ temperature_celsius?: number | undefined;
164308
+ /** Temperature in °F, if the device measures temperature. */
164309
+ temperature_fahrenheit?: number | undefined;
164310
+ /** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
164311
+ relative_humidity?: number | undefined;
164312
+ /** Noise level in decibels, if the device measures noise. */
164313
+ noise_level_decibels?: number | undefined;
164314
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. */
164315
+ noise_level_nrs?: number | undefined;
164316
+ /** Carbon dioxide concentration in parts per million, if the device measures it. */
164317
+ co2_ppm?: number | undefined;
164318
+ /** Carbon monoxide concentration in parts per million, if the device measures it. */
164319
+ co_ppm?: number | undefined;
164320
+ /** Air quality index, if the device measures it. */
164321
+ air_quality_index?: number | undefined;
164322
+ /** Mold risk level as reported by the device, if the device measures it. */
164323
+ mold_risk_level?: string | undefined;
164324
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
164325
+ is_occupied?: boolean | undefined;
164326
+ /** Number of occupants the device detects, if the device counts occupants. */
164327
+ occupant_count?: number | undefined;
164328
+ /** Indicates whether the device detects smoking, if the device measures it. */
164329
+ is_smoking_detected?: boolean | undefined;
164330
+ }[] | undefined;
164147
164331
  /** Indicates whether the device supports remote unlocking. */
164148
164332
  can_remotely_unlock?: boolean | undefined;
164149
164333
  /** Indicates whether the device supports remote locking. */
@@ -174147,6 +174331,8 @@ export type Routes = {
174147
174331
  allow_instant_key_customization?: boolean | undefined;
174148
174332
  /** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
174149
174333
  allow_notification_customization?: boolean | undefined;
174334
+ /** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
174335
+ allow_bridge_replacement?: boolean | undefined;
174150
174336
  } | undefined;
174151
174337
  } | undefined;
174152
174338
  }[] | undefined;