@seamapi/types 1.1186.0 → 1.1188.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/lib/seam/connect/models/customer/customer-portal.d.ts +19 -0
- package/lib/seam/connect/models/customer/customer-portal.js +5 -0
- package/lib/seam/connect/models/customer/customer-portal.js.map +1 -1
- package/lib/seam/connect/models/customization-profiles/customization-profile.d.ts +7 -0
- package/lib/seam/connect/models/devices/capability-properties/index.d.ts +9 -9
- package/lib/seam/connect/models/devices/capability-properties/thermostat.d.ts +9 -9
- package/lib/seam/connect/models/devices/capability-properties/thermostat.js +3 -3
- package/lib/seam/connect/models/devices/capability-properties/thermostat.js.map +1 -1
- package/lib/seam/connect/models/devices/device.d.ts +173 -311
- package/lib/seam/connect/models/devices/device.js +60 -73
- package/lib/seam/connect/models/devices/device.js.map +1 -1
- package/lib/seam/connect/models/devices/unmanaged-device.d.ts +71 -169
- package/lib/seam/connect/openapi.js +310 -166
- package/lib/seam/connect/openapi.js.map +1 -1
- package/lib/seam/connect/route-types.d.ts +1053 -867
- package/package.json +1 -1
- package/src/lib/seam/connect/models/customer/customer-portal.ts +7 -0
- package/src/lib/seam/connect/models/devices/capability-properties/thermostat.ts +3 -3
- package/src/lib/seam/connect/models/devices/device.ts +63 -76
- package/src/lib/seam/connect/openapi.ts +348 -190
- package/src/lib/seam/connect/route-types.ts +1087 -901
|
@@ -16230,58 +16230,9 @@ export type Routes = {
|
|
|
16230
16230
|
* @deprecated use offline_access_codes_enabled*/
|
|
16231
16231
|
supports_offline_access_codes?: boolean | undefined
|
|
16232
16232
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
16233
|
-
noise_level_decibels?:
|
|
16233
|
+
noise_level_decibels?: number | undefined
|
|
16234
16234
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
16235
16235
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
16236
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
16237
|
-
noise_level_nrs?: (number | null) | undefined
|
|
16238
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16239
|
-
co2_ppm?: (number | null) | undefined
|
|
16240
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16241
|
-
co_ppm?: (number | null) | undefined
|
|
16242
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
16243
|
-
air_quality_index?: (number | null) | undefined
|
|
16244
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
16245
|
-
mold_risk_level?: (string | null) | undefined
|
|
16246
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
16247
|
-
is_occupied?: (boolean | null) | undefined
|
|
16248
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
16249
|
-
occupant_count?: (number | null) | undefined
|
|
16250
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
16251
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
16252
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
16253
|
-
named_sensors?:
|
|
16254
|
-
| {
|
|
16255
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
16256
|
-
sensor_name: string
|
|
16257
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
16258
|
-
display_name: string
|
|
16259
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
16260
|
-
temperature_celsius?: (number | null) | undefined
|
|
16261
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
16262
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
16263
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
16264
|
-
relative_humidity?: (number | null) | undefined
|
|
16265
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
16266
|
-
noise_level_decibels?: (number | null) | undefined
|
|
16267
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
16268
|
-
noise_level_nrs?: (number | null) | undefined
|
|
16269
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16270
|
-
co2_ppm?: (number | null) | undefined
|
|
16271
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16272
|
-
co_ppm?: (number | null) | undefined
|
|
16273
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
16274
|
-
air_quality_index?: (number | null) | undefined
|
|
16275
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
16276
|
-
mold_risk_level?: (string | null) | undefined
|
|
16277
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
16278
|
-
is_occupied?: (boolean | null) | undefined
|
|
16279
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
16280
|
-
occupant_count?: (number | null) | undefined
|
|
16281
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
16282
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
16283
|
-
}[]
|
|
16284
|
-
| undefined
|
|
16285
16236
|
} & {
|
|
16286
16237
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
16287
16238
|
assa_abloy_credential_service_metadata?:
|
|
@@ -17374,11 +17325,11 @@ export type Routes = {
|
|
|
17374
17325
|
| undefined
|
|
17375
17326
|
} & {
|
|
17376
17327
|
/** Reported temperature in °F. */
|
|
17377
|
-
temperature_fahrenheit?:
|
|
17328
|
+
temperature_fahrenheit?: number | undefined
|
|
17378
17329
|
/** Reported temperature in °C. */
|
|
17379
|
-
temperature_celsius?:
|
|
17330
|
+
temperature_celsius?: number | undefined
|
|
17380
17331
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
17381
|
-
relative_humidity?:
|
|
17332
|
+
relative_humidity?: number | undefined
|
|
17382
17333
|
/** HVAC mode settings that the thermostat supports. */
|
|
17383
17334
|
available_hvac_mode_settings?:
|
|
17384
17335
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -18213,6 +18164,63 @@ export type Routes = {
|
|
|
18213
18164
|
image_url?: string | undefined
|
|
18214
18165
|
}
|
|
18215
18166
|
| undefined
|
|
18167
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
18168
|
+
temperature_celsius?: number | undefined
|
|
18169
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
18170
|
+
temperature_fahrenheit?: number | undefined
|
|
18171
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
18172
|
+
relative_humidity?: number | undefined
|
|
18173
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
18174
|
+
noise_level_decibels?: number | undefined
|
|
18175
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
18176
|
+
noise_level_nrs?: number | undefined
|
|
18177
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
18178
|
+
co2_ppm?: number | undefined
|
|
18179
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
18180
|
+
co_ppm?: number | undefined
|
|
18181
|
+
/** Air quality index, if the device measures it. */
|
|
18182
|
+
air_quality_index?: number | undefined
|
|
18183
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
18184
|
+
mold_risk_level?: string | undefined
|
|
18185
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
18186
|
+
is_occupied?: boolean | undefined
|
|
18187
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
18188
|
+
occupant_count?: number | undefined
|
|
18189
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
18190
|
+
is_smoking_detected?: boolean | undefined
|
|
18191
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
18192
|
+
named_sensors?:
|
|
18193
|
+
| {
|
|
18194
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
18195
|
+
sensor_name: string
|
|
18196
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
18197
|
+
display_name: string
|
|
18198
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
18199
|
+
temperature_celsius?: number | undefined
|
|
18200
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
18201
|
+
temperature_fahrenheit?: number | undefined
|
|
18202
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
18203
|
+
relative_humidity?: number | undefined
|
|
18204
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
18205
|
+
noise_level_decibels?: number | undefined
|
|
18206
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
18207
|
+
noise_level_nrs?: number | undefined
|
|
18208
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
18209
|
+
co2_ppm?: number | undefined
|
|
18210
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
18211
|
+
co_ppm?: number | undefined
|
|
18212
|
+
/** Air quality index, if the device measures it. */
|
|
18213
|
+
air_quality_index?: number | undefined
|
|
18214
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
18215
|
+
mold_risk_level?: string | undefined
|
|
18216
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
18217
|
+
is_occupied?: boolean | undefined
|
|
18218
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
18219
|
+
occupant_count?: number | undefined
|
|
18220
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
18221
|
+
is_smoking_detected?: boolean | undefined
|
|
18222
|
+
}[]
|
|
18223
|
+
| undefined
|
|
18216
18224
|
/** Indicates whether the device supports remote unlocking. */
|
|
18217
18225
|
can_remotely_unlock?: boolean | undefined
|
|
18218
18226
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -26067,58 +26075,9 @@ export type Routes = {
|
|
|
26067
26075
|
* @deprecated use offline_access_codes_enabled*/
|
|
26068
26076
|
supports_offline_access_codes?: boolean | undefined
|
|
26069
26077
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
26070
|
-
noise_level_decibels?:
|
|
26078
|
+
noise_level_decibels?: number | undefined
|
|
26071
26079
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
26072
26080
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
26073
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
26074
|
-
noise_level_nrs?: (number | null) | undefined
|
|
26075
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26076
|
-
co2_ppm?: (number | null) | undefined
|
|
26077
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26078
|
-
co_ppm?: (number | null) | undefined
|
|
26079
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
26080
|
-
air_quality_index?: (number | null) | undefined
|
|
26081
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
26082
|
-
mold_risk_level?: (string | null) | undefined
|
|
26083
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
26084
|
-
is_occupied?: (boolean | null) | undefined
|
|
26085
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
26086
|
-
occupant_count?: (number | null) | undefined
|
|
26087
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
26088
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
26089
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
26090
|
-
named_sensors?:
|
|
26091
|
-
| {
|
|
26092
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
26093
|
-
sensor_name: string
|
|
26094
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
26095
|
-
display_name: string
|
|
26096
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
26097
|
-
temperature_celsius?: (number | null) | undefined
|
|
26098
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
26099
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
26100
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
26101
|
-
relative_humidity?: (number | null) | undefined
|
|
26102
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
26103
|
-
noise_level_decibels?: (number | null) | undefined
|
|
26104
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
26105
|
-
noise_level_nrs?: (number | null) | undefined
|
|
26106
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26107
|
-
co2_ppm?: (number | null) | undefined
|
|
26108
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26109
|
-
co_ppm?: (number | null) | undefined
|
|
26110
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
26111
|
-
air_quality_index?: (number | null) | undefined
|
|
26112
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
26113
|
-
mold_risk_level?: (string | null) | undefined
|
|
26114
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
26115
|
-
is_occupied?: (boolean | null) | undefined
|
|
26116
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
26117
|
-
occupant_count?: (number | null) | undefined
|
|
26118
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
26119
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
26120
|
-
}[]
|
|
26121
|
-
| undefined
|
|
26122
26081
|
} & {
|
|
26123
26082
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
26124
26083
|
assa_abloy_credential_service_metadata?:
|
|
@@ -27211,11 +27170,11 @@ export type Routes = {
|
|
|
27211
27170
|
| undefined
|
|
27212
27171
|
} & {
|
|
27213
27172
|
/** Reported temperature in °F. */
|
|
27214
|
-
temperature_fahrenheit?:
|
|
27173
|
+
temperature_fahrenheit?: number | undefined
|
|
27215
27174
|
/** Reported temperature in °C. */
|
|
27216
|
-
temperature_celsius?:
|
|
27175
|
+
temperature_celsius?: number | undefined
|
|
27217
27176
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
27218
|
-
relative_humidity?:
|
|
27177
|
+
relative_humidity?: number | undefined
|
|
27219
27178
|
/** HVAC mode settings that the thermostat supports. */
|
|
27220
27179
|
available_hvac_mode_settings?:
|
|
27221
27180
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -28050,6 +28009,63 @@ export type Routes = {
|
|
|
28050
28009
|
image_url?: string | undefined
|
|
28051
28010
|
}
|
|
28052
28011
|
| undefined
|
|
28012
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
28013
|
+
temperature_celsius?: number | undefined
|
|
28014
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
28015
|
+
temperature_fahrenheit?: number | undefined
|
|
28016
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
28017
|
+
relative_humidity?: number | undefined
|
|
28018
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
28019
|
+
noise_level_decibels?: number | undefined
|
|
28020
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
28021
|
+
noise_level_nrs?: number | undefined
|
|
28022
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
28023
|
+
co2_ppm?: number | undefined
|
|
28024
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
28025
|
+
co_ppm?: number | undefined
|
|
28026
|
+
/** Air quality index, if the device measures it. */
|
|
28027
|
+
air_quality_index?: number | undefined
|
|
28028
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
28029
|
+
mold_risk_level?: string | undefined
|
|
28030
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
28031
|
+
is_occupied?: boolean | undefined
|
|
28032
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
28033
|
+
occupant_count?: number | undefined
|
|
28034
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
28035
|
+
is_smoking_detected?: boolean | undefined
|
|
28036
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
28037
|
+
named_sensors?:
|
|
28038
|
+
| {
|
|
28039
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
28040
|
+
sensor_name: string
|
|
28041
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
28042
|
+
display_name: string
|
|
28043
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
28044
|
+
temperature_celsius?: number | undefined
|
|
28045
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
28046
|
+
temperature_fahrenheit?: number | undefined
|
|
28047
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
28048
|
+
relative_humidity?: number | undefined
|
|
28049
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
28050
|
+
noise_level_decibels?: number | undefined
|
|
28051
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
28052
|
+
noise_level_nrs?: number | undefined
|
|
28053
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
28054
|
+
co2_ppm?: number | undefined
|
|
28055
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
28056
|
+
co_ppm?: number | undefined
|
|
28057
|
+
/** Air quality index, if the device measures it. */
|
|
28058
|
+
air_quality_index?: number | undefined
|
|
28059
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
28060
|
+
mold_risk_level?: string | undefined
|
|
28061
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
28062
|
+
is_occupied?: boolean | undefined
|
|
28063
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
28064
|
+
occupant_count?: number | undefined
|
|
28065
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
28066
|
+
is_smoking_detected?: boolean | undefined
|
|
28067
|
+
}[]
|
|
28068
|
+
| undefined
|
|
28053
28069
|
/** Indicates whether the device supports remote unlocking. */
|
|
28054
28070
|
can_remotely_unlock?: boolean | undefined
|
|
28055
28071
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -57234,6 +57250,8 @@ export type Routes = {
|
|
|
57234
57250
|
allow_instant_key_customization?: boolean | undefined
|
|
57235
57251
|
/** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
|
|
57236
57252
|
allow_notification_customization?: boolean | undefined
|
|
57253
|
+
/** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
|
|
57254
|
+
allow_bridge_replacement?: boolean | undefined
|
|
57237
57255
|
}
|
|
57238
57256
|
| undefined
|
|
57239
57257
|
}
|
|
@@ -58385,58 +58403,9 @@ export type Routes = {
|
|
|
58385
58403
|
* @deprecated use offline_access_codes_enabled*/
|
|
58386
58404
|
supports_offline_access_codes?: boolean | undefined
|
|
58387
58405
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
58388
|
-
noise_level_decibels?:
|
|
58406
|
+
noise_level_decibels?: number | undefined
|
|
58389
58407
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
58390
58408
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
58391
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
58392
|
-
noise_level_nrs?: (number | null) | undefined
|
|
58393
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58394
|
-
co2_ppm?: (number | null) | undefined
|
|
58395
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58396
|
-
co_ppm?: (number | null) | undefined
|
|
58397
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
58398
|
-
air_quality_index?: (number | null) | undefined
|
|
58399
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
58400
|
-
mold_risk_level?: (string | null) | undefined
|
|
58401
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
58402
|
-
is_occupied?: (boolean | null) | undefined
|
|
58403
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
58404
|
-
occupant_count?: (number | null) | undefined
|
|
58405
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
58406
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
58407
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
58408
|
-
named_sensors?:
|
|
58409
|
-
| {
|
|
58410
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
58411
|
-
sensor_name: string
|
|
58412
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
58413
|
-
display_name: string
|
|
58414
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
58415
|
-
temperature_celsius?: (number | null) | undefined
|
|
58416
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
58417
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
58418
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
58419
|
-
relative_humidity?: (number | null) | undefined
|
|
58420
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
58421
|
-
noise_level_decibels?: (number | null) | undefined
|
|
58422
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
58423
|
-
noise_level_nrs?: (number | null) | undefined
|
|
58424
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58425
|
-
co2_ppm?: (number | null) | undefined
|
|
58426
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58427
|
-
co_ppm?: (number | null) | undefined
|
|
58428
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
58429
|
-
air_quality_index?: (number | null) | undefined
|
|
58430
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
58431
|
-
mold_risk_level?: (string | null) | undefined
|
|
58432
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
58433
|
-
is_occupied?: (boolean | null) | undefined
|
|
58434
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
58435
|
-
occupant_count?: (number | null) | undefined
|
|
58436
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
58437
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
58438
|
-
}[]
|
|
58439
|
-
| undefined
|
|
58440
58409
|
} & {
|
|
58441
58410
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
58442
58411
|
assa_abloy_credential_service_metadata?:
|
|
@@ -59494,11 +59463,11 @@ export type Routes = {
|
|
|
59494
59463
|
| undefined
|
|
59495
59464
|
} & {
|
|
59496
59465
|
/** Reported temperature in °F. */
|
|
59497
|
-
temperature_fahrenheit?:
|
|
59466
|
+
temperature_fahrenheit?: number | undefined
|
|
59498
59467
|
/** Reported temperature in °C. */
|
|
59499
|
-
temperature_celsius?:
|
|
59468
|
+
temperature_celsius?: number | undefined
|
|
59500
59469
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
59501
|
-
relative_humidity?:
|
|
59470
|
+
relative_humidity?: number | undefined
|
|
59502
59471
|
/** HVAC mode settings that the thermostat supports. */
|
|
59503
59472
|
available_hvac_mode_settings?:
|
|
59504
59473
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -60311,6 +60280,63 @@ export type Routes = {
|
|
|
60311
60280
|
image_url?: string | undefined
|
|
60312
60281
|
}
|
|
60313
60282
|
| undefined
|
|
60283
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
60284
|
+
temperature_celsius?: number | undefined
|
|
60285
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
60286
|
+
temperature_fahrenheit?: number | undefined
|
|
60287
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
60288
|
+
relative_humidity?: number | undefined
|
|
60289
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
60290
|
+
noise_level_decibels?: number | undefined
|
|
60291
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
60292
|
+
noise_level_nrs?: number | undefined
|
|
60293
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
60294
|
+
co2_ppm?: number | undefined
|
|
60295
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
60296
|
+
co_ppm?: number | undefined
|
|
60297
|
+
/** Air quality index, if the device measures it. */
|
|
60298
|
+
air_quality_index?: number | undefined
|
|
60299
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
60300
|
+
mold_risk_level?: string | undefined
|
|
60301
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
60302
|
+
is_occupied?: boolean | undefined
|
|
60303
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
60304
|
+
occupant_count?: number | undefined
|
|
60305
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
60306
|
+
is_smoking_detected?: boolean | undefined
|
|
60307
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
60308
|
+
named_sensors?:
|
|
60309
|
+
| {
|
|
60310
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
60311
|
+
sensor_name: string
|
|
60312
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
60313
|
+
display_name: string
|
|
60314
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
60315
|
+
temperature_celsius?: number | undefined
|
|
60316
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
60317
|
+
temperature_fahrenheit?: number | undefined
|
|
60318
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
60319
|
+
relative_humidity?: number | undefined
|
|
60320
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
60321
|
+
noise_level_decibels?: number | undefined
|
|
60322
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
60323
|
+
noise_level_nrs?: number | undefined
|
|
60324
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
60325
|
+
co2_ppm?: number | undefined
|
|
60326
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
60327
|
+
co_ppm?: number | undefined
|
|
60328
|
+
/** Air quality index, if the device measures it. */
|
|
60329
|
+
air_quality_index?: number | undefined
|
|
60330
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
60331
|
+
mold_risk_level?: string | undefined
|
|
60332
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
60333
|
+
is_occupied?: boolean | undefined
|
|
60334
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
60335
|
+
occupant_count?: number | undefined
|
|
60336
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
60337
|
+
is_smoking_detected?: boolean | undefined
|
|
60338
|
+
}[]
|
|
60339
|
+
| undefined
|
|
60314
60340
|
/** Indicates whether the device supports remote unlocking. */
|
|
60315
60341
|
can_remotely_unlock?: boolean | undefined
|
|
60316
60342
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -60847,58 +60873,9 @@ export type Routes = {
|
|
|
60847
60873
|
* @deprecated use offline_access_codes_enabled*/
|
|
60848
60874
|
supports_offline_access_codes?: boolean | undefined
|
|
60849
60875
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
60850
|
-
noise_level_decibels?:
|
|
60876
|
+
noise_level_decibels?: number | undefined
|
|
60851
60877
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
60852
60878
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
60853
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
60854
|
-
noise_level_nrs?: (number | null) | undefined
|
|
60855
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60856
|
-
co2_ppm?: (number | null) | undefined
|
|
60857
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60858
|
-
co_ppm?: (number | null) | undefined
|
|
60859
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
60860
|
-
air_quality_index?: (number | null) | undefined
|
|
60861
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
60862
|
-
mold_risk_level?: (string | null) | undefined
|
|
60863
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
60864
|
-
is_occupied?: (boolean | null) | undefined
|
|
60865
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
60866
|
-
occupant_count?: (number | null) | undefined
|
|
60867
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
60868
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
60869
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
60870
|
-
named_sensors?:
|
|
60871
|
-
| {
|
|
60872
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
60873
|
-
sensor_name: string
|
|
60874
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
60875
|
-
display_name: string
|
|
60876
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
60877
|
-
temperature_celsius?: (number | null) | undefined
|
|
60878
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
60879
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
60880
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
60881
|
-
relative_humidity?: (number | null) | undefined
|
|
60882
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
60883
|
-
noise_level_decibels?: (number | null) | undefined
|
|
60884
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
60885
|
-
noise_level_nrs?: (number | null) | undefined
|
|
60886
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60887
|
-
co2_ppm?: (number | null) | undefined
|
|
60888
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60889
|
-
co_ppm?: (number | null) | undefined
|
|
60890
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
60891
|
-
air_quality_index?: (number | null) | undefined
|
|
60892
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
60893
|
-
mold_risk_level?: (string | null) | undefined
|
|
60894
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
60895
|
-
is_occupied?: (boolean | null) | undefined
|
|
60896
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
60897
|
-
occupant_count?: (number | null) | undefined
|
|
60898
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
60899
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
60900
|
-
}[]
|
|
60901
|
-
| undefined
|
|
60902
60879
|
} & {
|
|
60903
60880
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
60904
60881
|
assa_abloy_credential_service_metadata?:
|
|
@@ -61956,11 +61933,11 @@ export type Routes = {
|
|
|
61956
61933
|
| undefined
|
|
61957
61934
|
} & {
|
|
61958
61935
|
/** Reported temperature in °F. */
|
|
61959
|
-
temperature_fahrenheit?:
|
|
61936
|
+
temperature_fahrenheit?: number | undefined
|
|
61960
61937
|
/** Reported temperature in °C. */
|
|
61961
|
-
temperature_celsius?:
|
|
61938
|
+
temperature_celsius?: number | undefined
|
|
61962
61939
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
61963
|
-
relative_humidity?:
|
|
61940
|
+
relative_humidity?: number | undefined
|
|
61964
61941
|
/** HVAC mode settings that the thermostat supports. */
|
|
61965
61942
|
available_hvac_mode_settings?:
|
|
61966
61943
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -62773,6 +62750,63 @@ export type Routes = {
|
|
|
62773
62750
|
image_url?: string | undefined
|
|
62774
62751
|
}
|
|
62775
62752
|
| undefined
|
|
62753
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
62754
|
+
temperature_celsius?: number | undefined
|
|
62755
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
62756
|
+
temperature_fahrenheit?: number | undefined
|
|
62757
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
62758
|
+
relative_humidity?: number | undefined
|
|
62759
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
62760
|
+
noise_level_decibels?: number | undefined
|
|
62761
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
62762
|
+
noise_level_nrs?: number | undefined
|
|
62763
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
62764
|
+
co2_ppm?: number | undefined
|
|
62765
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
62766
|
+
co_ppm?: number | undefined
|
|
62767
|
+
/** Air quality index, if the device measures it. */
|
|
62768
|
+
air_quality_index?: number | undefined
|
|
62769
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
62770
|
+
mold_risk_level?: string | undefined
|
|
62771
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
62772
|
+
is_occupied?: boolean | undefined
|
|
62773
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
62774
|
+
occupant_count?: number | undefined
|
|
62775
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
62776
|
+
is_smoking_detected?: boolean | undefined
|
|
62777
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
62778
|
+
named_sensors?:
|
|
62779
|
+
| {
|
|
62780
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
62781
|
+
sensor_name: string
|
|
62782
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
62783
|
+
display_name: string
|
|
62784
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
62785
|
+
temperature_celsius?: number | undefined
|
|
62786
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
62787
|
+
temperature_fahrenheit?: number | undefined
|
|
62788
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
62789
|
+
relative_humidity?: number | undefined
|
|
62790
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
62791
|
+
noise_level_decibels?: number | undefined
|
|
62792
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
62793
|
+
noise_level_nrs?: number | undefined
|
|
62794
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
62795
|
+
co2_ppm?: number | undefined
|
|
62796
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
62797
|
+
co_ppm?: number | undefined
|
|
62798
|
+
/** Air quality index, if the device measures it. */
|
|
62799
|
+
air_quality_index?: number | undefined
|
|
62800
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
62801
|
+
mold_risk_level?: string | undefined
|
|
62802
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
62803
|
+
is_occupied?: boolean | undefined
|
|
62804
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
62805
|
+
occupant_count?: number | undefined
|
|
62806
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
62807
|
+
is_smoking_detected?: boolean | undefined
|
|
62808
|
+
}[]
|
|
62809
|
+
| undefined
|
|
62776
62810
|
/** Indicates whether the device supports remote unlocking. */
|
|
62777
62811
|
can_remotely_unlock?: boolean | undefined
|
|
62778
62812
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -77670,58 +77704,9 @@ export type Routes = {
|
|
|
77670
77704
|
* @deprecated use offline_access_codes_enabled*/
|
|
77671
77705
|
supports_offline_access_codes?: boolean | undefined
|
|
77672
77706
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
77673
|
-
noise_level_decibels?:
|
|
77707
|
+
noise_level_decibels?: number | undefined
|
|
77674
77708
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
77675
77709
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
77676
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
77677
|
-
noise_level_nrs?: (number | null) | undefined
|
|
77678
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77679
|
-
co2_ppm?: (number | null) | undefined
|
|
77680
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77681
|
-
co_ppm?: (number | null) | undefined
|
|
77682
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
77683
|
-
air_quality_index?: (number | null) | undefined
|
|
77684
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
77685
|
-
mold_risk_level?: (string | null) | undefined
|
|
77686
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
77687
|
-
is_occupied?: (boolean | null) | undefined
|
|
77688
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
77689
|
-
occupant_count?: (number | null) | undefined
|
|
77690
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
77691
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
77692
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
77693
|
-
named_sensors?:
|
|
77694
|
-
| {
|
|
77695
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
77696
|
-
sensor_name: string
|
|
77697
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
77698
|
-
display_name: string
|
|
77699
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
77700
|
-
temperature_celsius?: (number | null) | undefined
|
|
77701
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
77702
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
77703
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
77704
|
-
relative_humidity?: (number | null) | undefined
|
|
77705
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
77706
|
-
noise_level_decibels?: (number | null) | undefined
|
|
77707
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
77708
|
-
noise_level_nrs?: (number | null) | undefined
|
|
77709
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77710
|
-
co2_ppm?: (number | null) | undefined
|
|
77711
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77712
|
-
co_ppm?: (number | null) | undefined
|
|
77713
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
77714
|
-
air_quality_index?: (number | null) | undefined
|
|
77715
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
77716
|
-
mold_risk_level?: (string | null) | undefined
|
|
77717
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
77718
|
-
is_occupied?: (boolean | null) | undefined
|
|
77719
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
77720
|
-
occupant_count?: (number | null) | undefined
|
|
77721
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
77722
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
77723
|
-
}[]
|
|
77724
|
-
| undefined
|
|
77725
77710
|
} & {
|
|
77726
77711
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
77727
77712
|
assa_abloy_credential_service_metadata?:
|
|
@@ -78779,11 +78764,11 @@ export type Routes = {
|
|
|
78779
78764
|
| undefined
|
|
78780
78765
|
} & {
|
|
78781
78766
|
/** Reported temperature in °F. */
|
|
78782
|
-
temperature_fahrenheit?:
|
|
78767
|
+
temperature_fahrenheit?: number | undefined
|
|
78783
78768
|
/** Reported temperature in °C. */
|
|
78784
|
-
temperature_celsius?:
|
|
78769
|
+
temperature_celsius?: number | undefined
|
|
78785
78770
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
78786
|
-
relative_humidity?:
|
|
78771
|
+
relative_humidity?: number | undefined
|
|
78787
78772
|
/** HVAC mode settings that the thermostat supports. */
|
|
78788
78773
|
available_hvac_mode_settings?:
|
|
78789
78774
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -79596,6 +79581,63 @@ export type Routes = {
|
|
|
79596
79581
|
image_url?: string | undefined
|
|
79597
79582
|
}
|
|
79598
79583
|
| undefined
|
|
79584
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
79585
|
+
temperature_celsius?: number | undefined
|
|
79586
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
79587
|
+
temperature_fahrenheit?: number | undefined
|
|
79588
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
79589
|
+
relative_humidity?: number | undefined
|
|
79590
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
79591
|
+
noise_level_decibels?: number | undefined
|
|
79592
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
79593
|
+
noise_level_nrs?: number | undefined
|
|
79594
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
79595
|
+
co2_ppm?: number | undefined
|
|
79596
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
79597
|
+
co_ppm?: number | undefined
|
|
79598
|
+
/** Air quality index, if the device measures it. */
|
|
79599
|
+
air_quality_index?: number | undefined
|
|
79600
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
79601
|
+
mold_risk_level?: string | undefined
|
|
79602
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
79603
|
+
is_occupied?: boolean | undefined
|
|
79604
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
79605
|
+
occupant_count?: number | undefined
|
|
79606
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
79607
|
+
is_smoking_detected?: boolean | undefined
|
|
79608
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
79609
|
+
named_sensors?:
|
|
79610
|
+
| {
|
|
79611
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
79612
|
+
sensor_name: string
|
|
79613
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
79614
|
+
display_name: string
|
|
79615
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
79616
|
+
temperature_celsius?: number | undefined
|
|
79617
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
79618
|
+
temperature_fahrenheit?: number | undefined
|
|
79619
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
79620
|
+
relative_humidity?: number | undefined
|
|
79621
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
79622
|
+
noise_level_decibels?: number | undefined
|
|
79623
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
79624
|
+
noise_level_nrs?: number | undefined
|
|
79625
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
79626
|
+
co2_ppm?: number | undefined
|
|
79627
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
79628
|
+
co_ppm?: number | undefined
|
|
79629
|
+
/** Air quality index, if the device measures it. */
|
|
79630
|
+
air_quality_index?: number | undefined
|
|
79631
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
79632
|
+
mold_risk_level?: string | undefined
|
|
79633
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
79634
|
+
is_occupied?: boolean | undefined
|
|
79635
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
79636
|
+
occupant_count?: number | undefined
|
|
79637
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
79638
|
+
is_smoking_detected?: boolean | undefined
|
|
79639
|
+
}[]
|
|
79640
|
+
| undefined
|
|
79599
79641
|
/** Indicates whether the device supports remote unlocking. */
|
|
79600
79642
|
can_remotely_unlock?: boolean | undefined
|
|
79601
79643
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -79829,58 +79871,9 @@ export type Routes = {
|
|
|
79829
79871
|
* @deprecated use offline_access_codes_enabled*/
|
|
79830
79872
|
supports_offline_access_codes?: boolean | undefined
|
|
79831
79873
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
79832
|
-
noise_level_decibels?:
|
|
79874
|
+
noise_level_decibels?: number | undefined
|
|
79833
79875
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
79834
79876
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
79835
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
79836
|
-
noise_level_nrs?: (number | null) | undefined
|
|
79837
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79838
|
-
co2_ppm?: (number | null) | undefined
|
|
79839
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79840
|
-
co_ppm?: (number | null) | undefined
|
|
79841
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
79842
|
-
air_quality_index?: (number | null) | undefined
|
|
79843
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
79844
|
-
mold_risk_level?: (string | null) | undefined
|
|
79845
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
79846
|
-
is_occupied?: (boolean | null) | undefined
|
|
79847
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
79848
|
-
occupant_count?: (number | null) | undefined
|
|
79849
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
79850
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
79851
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
79852
|
-
named_sensors?:
|
|
79853
|
-
| {
|
|
79854
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
79855
|
-
sensor_name: string
|
|
79856
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
79857
|
-
display_name: string
|
|
79858
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
79859
|
-
temperature_celsius?: (number | null) | undefined
|
|
79860
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
79861
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
79862
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
79863
|
-
relative_humidity?: (number | null) | undefined
|
|
79864
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
79865
|
-
noise_level_decibels?: (number | null) | undefined
|
|
79866
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
79867
|
-
noise_level_nrs?: (number | null) | undefined
|
|
79868
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79869
|
-
co2_ppm?: (number | null) | undefined
|
|
79870
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79871
|
-
co_ppm?: (number | null) | undefined
|
|
79872
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
79873
|
-
air_quality_index?: (number | null) | undefined
|
|
79874
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
79875
|
-
mold_risk_level?: (string | null) | undefined
|
|
79876
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
79877
|
-
is_occupied?: (boolean | null) | undefined
|
|
79878
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
79879
|
-
occupant_count?: (number | null) | undefined
|
|
79880
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
79881
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
79882
|
-
}[]
|
|
79883
|
-
| undefined
|
|
79884
79877
|
} & {
|
|
79885
79878
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
79886
79879
|
assa_abloy_credential_service_metadata?:
|
|
@@ -80938,11 +80931,11 @@ export type Routes = {
|
|
|
80938
80931
|
| undefined
|
|
80939
80932
|
} & {
|
|
80940
80933
|
/** Reported temperature in °F. */
|
|
80941
|
-
temperature_fahrenheit?:
|
|
80934
|
+
temperature_fahrenheit?: number | undefined
|
|
80942
80935
|
/** Reported temperature in °C. */
|
|
80943
|
-
temperature_celsius?:
|
|
80936
|
+
temperature_celsius?: number | undefined
|
|
80944
80937
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
80945
|
-
relative_humidity?:
|
|
80938
|
+
relative_humidity?: number | undefined
|
|
80946
80939
|
/** HVAC mode settings that the thermostat supports. */
|
|
80947
80940
|
available_hvac_mode_settings?:
|
|
80948
80941
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -81755,6 +81748,63 @@ export type Routes = {
|
|
|
81755
81748
|
image_url?: string | undefined
|
|
81756
81749
|
}
|
|
81757
81750
|
| undefined
|
|
81751
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
81752
|
+
temperature_celsius?: number | undefined
|
|
81753
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
81754
|
+
temperature_fahrenheit?: number | undefined
|
|
81755
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
81756
|
+
relative_humidity?: number | undefined
|
|
81757
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
81758
|
+
noise_level_decibels?: number | undefined
|
|
81759
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
81760
|
+
noise_level_nrs?: number | undefined
|
|
81761
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
81762
|
+
co2_ppm?: number | undefined
|
|
81763
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
81764
|
+
co_ppm?: number | undefined
|
|
81765
|
+
/** Air quality index, if the device measures it. */
|
|
81766
|
+
air_quality_index?: number | undefined
|
|
81767
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
81768
|
+
mold_risk_level?: string | undefined
|
|
81769
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
81770
|
+
is_occupied?: boolean | undefined
|
|
81771
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
81772
|
+
occupant_count?: number | undefined
|
|
81773
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
81774
|
+
is_smoking_detected?: boolean | undefined
|
|
81775
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
81776
|
+
named_sensors?:
|
|
81777
|
+
| {
|
|
81778
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
81779
|
+
sensor_name: string
|
|
81780
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
81781
|
+
display_name: string
|
|
81782
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
81783
|
+
temperature_celsius?: number | undefined
|
|
81784
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
81785
|
+
temperature_fahrenheit?: number | undefined
|
|
81786
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
81787
|
+
relative_humidity?: number | undefined
|
|
81788
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
81789
|
+
noise_level_decibels?: number | undefined
|
|
81790
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
81791
|
+
noise_level_nrs?: number | undefined
|
|
81792
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
81793
|
+
co2_ppm?: number | undefined
|
|
81794
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
81795
|
+
co_ppm?: number | undefined
|
|
81796
|
+
/** Air quality index, if the device measures it. */
|
|
81797
|
+
air_quality_index?: number | undefined
|
|
81798
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
81799
|
+
mold_risk_level?: string | undefined
|
|
81800
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
81801
|
+
is_occupied?: boolean | undefined
|
|
81802
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
81803
|
+
occupant_count?: number | undefined
|
|
81804
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
81805
|
+
is_smoking_detected?: boolean | undefined
|
|
81806
|
+
}[]
|
|
81807
|
+
| undefined
|
|
81758
81808
|
/** Indicates whether the device supports remote unlocking. */
|
|
81759
81809
|
can_remotely_unlock?: boolean | undefined
|
|
81760
81810
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -82126,58 +82176,9 @@ export type Routes = {
|
|
|
82126
82176
|
* @deprecated use offline_access_codes_enabled*/
|
|
82127
82177
|
supports_offline_access_codes?: boolean | undefined
|
|
82128
82178
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
82129
|
-
noise_level_decibels?:
|
|
82179
|
+
noise_level_decibels?: number | undefined
|
|
82130
82180
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
82131
82181
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
82132
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
82133
|
-
noise_level_nrs?: (number | null) | undefined
|
|
82134
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82135
|
-
co2_ppm?: (number | null) | undefined
|
|
82136
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82137
|
-
co_ppm?: (number | null) | undefined
|
|
82138
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
82139
|
-
air_quality_index?: (number | null) | undefined
|
|
82140
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
82141
|
-
mold_risk_level?: (string | null) | undefined
|
|
82142
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
82143
|
-
is_occupied?: (boolean | null) | undefined
|
|
82144
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
82145
|
-
occupant_count?: (number | null) | undefined
|
|
82146
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
82147
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
82148
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
82149
|
-
named_sensors?:
|
|
82150
|
-
| {
|
|
82151
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
82152
|
-
sensor_name: string
|
|
82153
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
82154
|
-
display_name: string
|
|
82155
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
82156
|
-
temperature_celsius?: (number | null) | undefined
|
|
82157
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
82158
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
82159
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
82160
|
-
relative_humidity?: (number | null) | undefined
|
|
82161
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
82162
|
-
noise_level_decibels?: (number | null) | undefined
|
|
82163
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
82164
|
-
noise_level_nrs?: (number | null) | undefined
|
|
82165
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82166
|
-
co2_ppm?: (number | null) | undefined
|
|
82167
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82168
|
-
co_ppm?: (number | null) | undefined
|
|
82169
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
82170
|
-
air_quality_index?: (number | null) | undefined
|
|
82171
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
82172
|
-
mold_risk_level?: (string | null) | undefined
|
|
82173
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
82174
|
-
is_occupied?: (boolean | null) | undefined
|
|
82175
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
82176
|
-
occupant_count?: (number | null) | undefined
|
|
82177
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
82178
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
82179
|
-
}[]
|
|
82180
|
-
| undefined
|
|
82181
82182
|
} & {
|
|
82182
82183
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
82183
82184
|
assa_abloy_credential_service_metadata?:
|
|
@@ -83235,11 +83236,11 @@ export type Routes = {
|
|
|
83235
83236
|
| undefined
|
|
83236
83237
|
} & {
|
|
83237
83238
|
/** Reported temperature in °F. */
|
|
83238
|
-
temperature_fahrenheit?:
|
|
83239
|
+
temperature_fahrenheit?: number | undefined
|
|
83239
83240
|
/** Reported temperature in °C. */
|
|
83240
|
-
temperature_celsius?:
|
|
83241
|
+
temperature_celsius?: number | undefined
|
|
83241
83242
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
83242
|
-
relative_humidity?:
|
|
83243
|
+
relative_humidity?: number | undefined
|
|
83243
83244
|
/** HVAC mode settings that the thermostat supports. */
|
|
83244
83245
|
available_hvac_mode_settings?:
|
|
83245
83246
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -84052,6 +84053,63 @@ export type Routes = {
|
|
|
84052
84053
|
image_url?: string | undefined
|
|
84053
84054
|
}
|
|
84054
84055
|
| undefined
|
|
84056
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
84057
|
+
temperature_celsius?: number | undefined
|
|
84058
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
84059
|
+
temperature_fahrenheit?: number | undefined
|
|
84060
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
84061
|
+
relative_humidity?: number | undefined
|
|
84062
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
84063
|
+
noise_level_decibels?: number | undefined
|
|
84064
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
84065
|
+
noise_level_nrs?: number | undefined
|
|
84066
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
84067
|
+
co2_ppm?: number | undefined
|
|
84068
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
84069
|
+
co_ppm?: number | undefined
|
|
84070
|
+
/** Air quality index, if the device measures it. */
|
|
84071
|
+
air_quality_index?: number | undefined
|
|
84072
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
84073
|
+
mold_risk_level?: string | undefined
|
|
84074
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
84075
|
+
is_occupied?: boolean | undefined
|
|
84076
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
84077
|
+
occupant_count?: number | undefined
|
|
84078
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
84079
|
+
is_smoking_detected?: boolean | undefined
|
|
84080
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
84081
|
+
named_sensors?:
|
|
84082
|
+
| {
|
|
84083
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
84084
|
+
sensor_name: string
|
|
84085
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
84086
|
+
display_name: string
|
|
84087
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
84088
|
+
temperature_celsius?: number | undefined
|
|
84089
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
84090
|
+
temperature_fahrenheit?: number | undefined
|
|
84091
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
84092
|
+
relative_humidity?: number | undefined
|
|
84093
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
84094
|
+
noise_level_decibels?: number | undefined
|
|
84095
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
84096
|
+
noise_level_nrs?: number | undefined
|
|
84097
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
84098
|
+
co2_ppm?: number | undefined
|
|
84099
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
84100
|
+
co_ppm?: number | undefined
|
|
84101
|
+
/** Air quality index, if the device measures it. */
|
|
84102
|
+
air_quality_index?: number | undefined
|
|
84103
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
84104
|
+
mold_risk_level?: string | undefined
|
|
84105
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
84106
|
+
is_occupied?: boolean | undefined
|
|
84107
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
84108
|
+
occupant_count?: number | undefined
|
|
84109
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
84110
|
+
is_smoking_detected?: boolean | undefined
|
|
84111
|
+
}[]
|
|
84112
|
+
| undefined
|
|
84055
84113
|
/** Indicates whether the device supports remote unlocking. */
|
|
84056
84114
|
can_remotely_unlock?: boolean | undefined
|
|
84057
84115
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -84284,58 +84342,9 @@ export type Routes = {
|
|
|
84284
84342
|
* @deprecated use offline_access_codes_enabled*/
|
|
84285
84343
|
supports_offline_access_codes?: boolean | undefined
|
|
84286
84344
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
84287
|
-
noise_level_decibels?:
|
|
84345
|
+
noise_level_decibels?: number | undefined
|
|
84288
84346
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
84289
84347
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
84290
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
84291
|
-
noise_level_nrs?: (number | null) | undefined
|
|
84292
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84293
|
-
co2_ppm?: (number | null) | undefined
|
|
84294
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84295
|
-
co_ppm?: (number | null) | undefined
|
|
84296
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
84297
|
-
air_quality_index?: (number | null) | undefined
|
|
84298
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
84299
|
-
mold_risk_level?: (string | null) | undefined
|
|
84300
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
84301
|
-
is_occupied?: (boolean | null) | undefined
|
|
84302
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
84303
|
-
occupant_count?: (number | null) | undefined
|
|
84304
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
84305
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
84306
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
84307
|
-
named_sensors?:
|
|
84308
|
-
| {
|
|
84309
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
84310
|
-
sensor_name: string
|
|
84311
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
84312
|
-
display_name: string
|
|
84313
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
84314
|
-
temperature_celsius?: (number | null) | undefined
|
|
84315
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
84316
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
84317
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
84318
|
-
relative_humidity?: (number | null) | undefined
|
|
84319
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
84320
|
-
noise_level_decibels?: (number | null) | undefined
|
|
84321
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
84322
|
-
noise_level_nrs?: (number | null) | undefined
|
|
84323
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84324
|
-
co2_ppm?: (number | null) | undefined
|
|
84325
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84326
|
-
co_ppm?: (number | null) | undefined
|
|
84327
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
84328
|
-
air_quality_index?: (number | null) | undefined
|
|
84329
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
84330
|
-
mold_risk_level?: (string | null) | undefined
|
|
84331
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
84332
|
-
is_occupied?: (boolean | null) | undefined
|
|
84333
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
84334
|
-
occupant_count?: (number | null) | undefined
|
|
84335
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
84336
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
84337
|
-
}[]
|
|
84338
|
-
| undefined
|
|
84339
84348
|
} & {
|
|
84340
84349
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
84341
84350
|
assa_abloy_credential_service_metadata?:
|
|
@@ -85393,11 +85402,11 @@ export type Routes = {
|
|
|
85393
85402
|
| undefined
|
|
85394
85403
|
} & {
|
|
85395
85404
|
/** Reported temperature in °F. */
|
|
85396
|
-
temperature_fahrenheit?:
|
|
85405
|
+
temperature_fahrenheit?: number | undefined
|
|
85397
85406
|
/** Reported temperature in °C. */
|
|
85398
|
-
temperature_celsius?:
|
|
85407
|
+
temperature_celsius?: number | undefined
|
|
85399
85408
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
85400
|
-
relative_humidity?:
|
|
85409
|
+
relative_humidity?: number | undefined
|
|
85401
85410
|
/** HVAC mode settings that the thermostat supports. */
|
|
85402
85411
|
available_hvac_mode_settings?:
|
|
85403
85412
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -86210,6 +86219,63 @@ export type Routes = {
|
|
|
86210
86219
|
image_url?: string | undefined
|
|
86211
86220
|
}
|
|
86212
86221
|
| undefined
|
|
86222
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
86223
|
+
temperature_celsius?: number | undefined
|
|
86224
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
86225
|
+
temperature_fahrenheit?: number | undefined
|
|
86226
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
86227
|
+
relative_humidity?: number | undefined
|
|
86228
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
86229
|
+
noise_level_decibels?: number | undefined
|
|
86230
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
86231
|
+
noise_level_nrs?: number | undefined
|
|
86232
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
86233
|
+
co2_ppm?: number | undefined
|
|
86234
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
86235
|
+
co_ppm?: number | undefined
|
|
86236
|
+
/** Air quality index, if the device measures it. */
|
|
86237
|
+
air_quality_index?: number | undefined
|
|
86238
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
86239
|
+
mold_risk_level?: string | undefined
|
|
86240
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
86241
|
+
is_occupied?: boolean | undefined
|
|
86242
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
86243
|
+
occupant_count?: number | undefined
|
|
86244
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
86245
|
+
is_smoking_detected?: boolean | undefined
|
|
86246
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
86247
|
+
named_sensors?:
|
|
86248
|
+
| {
|
|
86249
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
86250
|
+
sensor_name: string
|
|
86251
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
86252
|
+
display_name: string
|
|
86253
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
86254
|
+
temperature_celsius?: number | undefined
|
|
86255
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
86256
|
+
temperature_fahrenheit?: number | undefined
|
|
86257
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
86258
|
+
relative_humidity?: number | undefined
|
|
86259
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
86260
|
+
noise_level_decibels?: number | undefined
|
|
86261
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
86262
|
+
noise_level_nrs?: number | undefined
|
|
86263
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
86264
|
+
co2_ppm?: number | undefined
|
|
86265
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
86266
|
+
co_ppm?: number | undefined
|
|
86267
|
+
/** Air quality index, if the device measures it. */
|
|
86268
|
+
air_quality_index?: number | undefined
|
|
86269
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
86270
|
+
mold_risk_level?: string | undefined
|
|
86271
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
86272
|
+
is_occupied?: boolean | undefined
|
|
86273
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
86274
|
+
occupant_count?: number | undefined
|
|
86275
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
86276
|
+
is_smoking_detected?: boolean | undefined
|
|
86277
|
+
}[]
|
|
86278
|
+
| undefined
|
|
86213
86279
|
/** Indicates whether the device supports remote unlocking. */
|
|
86214
86280
|
can_remotely_unlock?: boolean | undefined
|
|
86215
86281
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -96693,58 +96759,9 @@ export type Routes = {
|
|
|
96693
96759
|
* @deprecated use offline_access_codes_enabled*/
|
|
96694
96760
|
supports_offline_access_codes?: boolean | undefined
|
|
96695
96761
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
96696
|
-
noise_level_decibels?:
|
|
96762
|
+
noise_level_decibels?: number | undefined
|
|
96697
96763
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
96698
96764
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
96699
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
96700
|
-
noise_level_nrs?: (number | null) | undefined
|
|
96701
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96702
|
-
co2_ppm?: (number | null) | undefined
|
|
96703
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96704
|
-
co_ppm?: (number | null) | undefined
|
|
96705
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
96706
|
-
air_quality_index?: (number | null) | undefined
|
|
96707
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
96708
|
-
mold_risk_level?: (string | null) | undefined
|
|
96709
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
96710
|
-
is_occupied?: (boolean | null) | undefined
|
|
96711
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
96712
|
-
occupant_count?: (number | null) | undefined
|
|
96713
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
96714
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
96715
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
96716
|
-
named_sensors?:
|
|
96717
|
-
| {
|
|
96718
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
96719
|
-
sensor_name: string
|
|
96720
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
96721
|
-
display_name: string
|
|
96722
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
96723
|
-
temperature_celsius?: (number | null) | undefined
|
|
96724
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
96725
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
96726
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
96727
|
-
relative_humidity?: (number | null) | undefined
|
|
96728
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
96729
|
-
noise_level_decibels?: (number | null) | undefined
|
|
96730
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
96731
|
-
noise_level_nrs?: (number | null) | undefined
|
|
96732
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96733
|
-
co2_ppm?: (number | null) | undefined
|
|
96734
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96735
|
-
co_ppm?: (number | null) | undefined
|
|
96736
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
96737
|
-
air_quality_index?: (number | null) | undefined
|
|
96738
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
96739
|
-
mold_risk_level?: (string | null) | undefined
|
|
96740
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
96741
|
-
is_occupied?: (boolean | null) | undefined
|
|
96742
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
96743
|
-
occupant_count?: (number | null) | undefined
|
|
96744
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
96745
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
96746
|
-
}[]
|
|
96747
|
-
| undefined
|
|
96748
96765
|
} & {
|
|
96749
96766
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
96750
96767
|
assa_abloy_credential_service_metadata?:
|
|
@@ -97802,11 +97819,11 @@ export type Routes = {
|
|
|
97802
97819
|
| undefined
|
|
97803
97820
|
} & {
|
|
97804
97821
|
/** Reported temperature in °F. */
|
|
97805
|
-
temperature_fahrenheit?:
|
|
97822
|
+
temperature_fahrenheit?: number | undefined
|
|
97806
97823
|
/** Reported temperature in °C. */
|
|
97807
|
-
temperature_celsius?:
|
|
97824
|
+
temperature_celsius?: number | undefined
|
|
97808
97825
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
97809
|
-
relative_humidity?:
|
|
97826
|
+
relative_humidity?: number | undefined
|
|
97810
97827
|
/** HVAC mode settings that the thermostat supports. */
|
|
97811
97828
|
available_hvac_mode_settings?:
|
|
97812
97829
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -98619,6 +98636,63 @@ export type Routes = {
|
|
|
98619
98636
|
image_url?: string | undefined
|
|
98620
98637
|
}
|
|
98621
98638
|
| undefined
|
|
98639
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
98640
|
+
temperature_celsius?: number | undefined
|
|
98641
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
98642
|
+
temperature_fahrenheit?: number | undefined
|
|
98643
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
98644
|
+
relative_humidity?: number | undefined
|
|
98645
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
98646
|
+
noise_level_decibels?: number | undefined
|
|
98647
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
98648
|
+
noise_level_nrs?: number | undefined
|
|
98649
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
98650
|
+
co2_ppm?: number | undefined
|
|
98651
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
98652
|
+
co_ppm?: number | undefined
|
|
98653
|
+
/** Air quality index, if the device measures it. */
|
|
98654
|
+
air_quality_index?: number | undefined
|
|
98655
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
98656
|
+
mold_risk_level?: string | undefined
|
|
98657
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
98658
|
+
is_occupied?: boolean | undefined
|
|
98659
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
98660
|
+
occupant_count?: number | undefined
|
|
98661
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
98662
|
+
is_smoking_detected?: boolean | undefined
|
|
98663
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
98664
|
+
named_sensors?:
|
|
98665
|
+
| {
|
|
98666
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
98667
|
+
sensor_name: string
|
|
98668
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
98669
|
+
display_name: string
|
|
98670
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
98671
|
+
temperature_celsius?: number | undefined
|
|
98672
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
98673
|
+
temperature_fahrenheit?: number | undefined
|
|
98674
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
98675
|
+
relative_humidity?: number | undefined
|
|
98676
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
98677
|
+
noise_level_decibels?: number | undefined
|
|
98678
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
98679
|
+
noise_level_nrs?: number | undefined
|
|
98680
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
98681
|
+
co2_ppm?: number | undefined
|
|
98682
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
98683
|
+
co_ppm?: number | undefined
|
|
98684
|
+
/** Air quality index, if the device measures it. */
|
|
98685
|
+
air_quality_index?: number | undefined
|
|
98686
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
98687
|
+
mold_risk_level?: string | undefined
|
|
98688
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
98689
|
+
is_occupied?: boolean | undefined
|
|
98690
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
98691
|
+
occupant_count?: number | undefined
|
|
98692
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
98693
|
+
is_smoking_detected?: boolean | undefined
|
|
98694
|
+
}[]
|
|
98695
|
+
| undefined
|
|
98622
98696
|
/** Indicates whether the device supports remote unlocking. */
|
|
98623
98697
|
can_remotely_unlock?: boolean | undefined
|
|
98624
98698
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -98851,58 +98925,9 @@ export type Routes = {
|
|
|
98851
98925
|
* @deprecated use offline_access_codes_enabled*/
|
|
98852
98926
|
supports_offline_access_codes?: boolean | undefined
|
|
98853
98927
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
98854
|
-
noise_level_decibels?:
|
|
98928
|
+
noise_level_decibels?: number | undefined
|
|
98855
98929
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
98856
98930
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
98857
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
98858
|
-
noise_level_nrs?: (number | null) | undefined
|
|
98859
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98860
|
-
co2_ppm?: (number | null) | undefined
|
|
98861
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98862
|
-
co_ppm?: (number | null) | undefined
|
|
98863
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
98864
|
-
air_quality_index?: (number | null) | undefined
|
|
98865
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
98866
|
-
mold_risk_level?: (string | null) | undefined
|
|
98867
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
98868
|
-
is_occupied?: (boolean | null) | undefined
|
|
98869
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
98870
|
-
occupant_count?: (number | null) | undefined
|
|
98871
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
98872
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
98873
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
98874
|
-
named_sensors?:
|
|
98875
|
-
| {
|
|
98876
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
98877
|
-
sensor_name: string
|
|
98878
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
98879
|
-
display_name: string
|
|
98880
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
98881
|
-
temperature_celsius?: (number | null) | undefined
|
|
98882
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
98883
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
98884
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
98885
|
-
relative_humidity?: (number | null) | undefined
|
|
98886
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
98887
|
-
noise_level_decibels?: (number | null) | undefined
|
|
98888
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
98889
|
-
noise_level_nrs?: (number | null) | undefined
|
|
98890
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98891
|
-
co2_ppm?: (number | null) | undefined
|
|
98892
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98893
|
-
co_ppm?: (number | null) | undefined
|
|
98894
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
98895
|
-
air_quality_index?: (number | null) | undefined
|
|
98896
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
98897
|
-
mold_risk_level?: (string | null) | undefined
|
|
98898
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
98899
|
-
is_occupied?: (boolean | null) | undefined
|
|
98900
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
98901
|
-
occupant_count?: (number | null) | undefined
|
|
98902
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
98903
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
98904
|
-
}[]
|
|
98905
|
-
| undefined
|
|
98906
98931
|
} & {
|
|
98907
98932
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
98908
98933
|
assa_abloy_credential_service_metadata?:
|
|
@@ -99960,11 +99985,11 @@ export type Routes = {
|
|
|
99960
99985
|
| undefined
|
|
99961
99986
|
} & {
|
|
99962
99987
|
/** Reported temperature in °F. */
|
|
99963
|
-
temperature_fahrenheit?:
|
|
99988
|
+
temperature_fahrenheit?: number | undefined
|
|
99964
99989
|
/** Reported temperature in °C. */
|
|
99965
|
-
temperature_celsius?:
|
|
99990
|
+
temperature_celsius?: number | undefined
|
|
99966
99991
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
99967
|
-
relative_humidity?:
|
|
99992
|
+
relative_humidity?: number | undefined
|
|
99968
99993
|
/** HVAC mode settings that the thermostat supports. */
|
|
99969
99994
|
available_hvac_mode_settings?:
|
|
99970
99995
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -100777,6 +100802,63 @@ export type Routes = {
|
|
|
100777
100802
|
image_url?: string | undefined
|
|
100778
100803
|
}
|
|
100779
100804
|
| undefined
|
|
100805
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
100806
|
+
temperature_celsius?: number | undefined
|
|
100807
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
100808
|
+
temperature_fahrenheit?: number | undefined
|
|
100809
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
100810
|
+
relative_humidity?: number | undefined
|
|
100811
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
100812
|
+
noise_level_decibels?: number | undefined
|
|
100813
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
100814
|
+
noise_level_nrs?: number | undefined
|
|
100815
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
100816
|
+
co2_ppm?: number | undefined
|
|
100817
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
100818
|
+
co_ppm?: number | undefined
|
|
100819
|
+
/** Air quality index, if the device measures it. */
|
|
100820
|
+
air_quality_index?: number | undefined
|
|
100821
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
100822
|
+
mold_risk_level?: string | undefined
|
|
100823
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
100824
|
+
is_occupied?: boolean | undefined
|
|
100825
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
100826
|
+
occupant_count?: number | undefined
|
|
100827
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
100828
|
+
is_smoking_detected?: boolean | undefined
|
|
100829
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
100830
|
+
named_sensors?:
|
|
100831
|
+
| {
|
|
100832
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
100833
|
+
sensor_name: string
|
|
100834
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
100835
|
+
display_name: string
|
|
100836
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
100837
|
+
temperature_celsius?: number | undefined
|
|
100838
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
100839
|
+
temperature_fahrenheit?: number | undefined
|
|
100840
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
100841
|
+
relative_humidity?: number | undefined
|
|
100842
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
100843
|
+
noise_level_decibels?: number | undefined
|
|
100844
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
100845
|
+
noise_level_nrs?: number | undefined
|
|
100846
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
100847
|
+
co2_ppm?: number | undefined
|
|
100848
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
100849
|
+
co_ppm?: number | undefined
|
|
100850
|
+
/** Air quality index, if the device measures it. */
|
|
100851
|
+
air_quality_index?: number | undefined
|
|
100852
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
100853
|
+
mold_risk_level?: string | undefined
|
|
100854
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
100855
|
+
is_occupied?: boolean | undefined
|
|
100856
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
100857
|
+
occupant_count?: number | undefined
|
|
100858
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
100859
|
+
is_smoking_detected?: boolean | undefined
|
|
100860
|
+
}[]
|
|
100861
|
+
| undefined
|
|
100780
100862
|
/** Indicates whether the device supports remote unlocking. */
|
|
100781
100863
|
can_remotely_unlock?: boolean | undefined
|
|
100782
100864
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -110498,6 +110580,21 @@ export type Routes = {
|
|
|
110498
110580
|
}
|
|
110499
110581
|
maxDuration: undefined
|
|
110500
110582
|
}
|
|
110583
|
+
'/seam/console/v1/connected_accounts/replace_bridge': {
|
|
110584
|
+
route: '/seam/console/v1/connected_accounts/replace_bridge'
|
|
110585
|
+
method: 'POST'
|
|
110586
|
+
queryParams: {}
|
|
110587
|
+
jsonBody: {
|
|
110588
|
+
/** ID of the connected account whose Seam Bridge you want to replace. */
|
|
110589
|
+
connected_account_id: string
|
|
110590
|
+
/** Pairing code shown in the new Seam Bridge app. */
|
|
110591
|
+
pairing_code: string
|
|
110592
|
+
}
|
|
110593
|
+
commonParams: {}
|
|
110594
|
+
formData: {}
|
|
110595
|
+
jsonResponse: {}
|
|
110596
|
+
maxDuration: undefined
|
|
110597
|
+
}
|
|
110501
110598
|
'/seam/console/v1/credits/checkout/start': {
|
|
110502
110599
|
route: '/seam/console/v1/credits/checkout/start'
|
|
110503
110600
|
method: 'POST'
|
|
@@ -111387,6 +111484,8 @@ export type Routes = {
|
|
|
111387
111484
|
allow_instant_key_customization?: boolean | undefined
|
|
111388
111485
|
/** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
|
|
111389
111486
|
allow_notification_customization?: boolean | undefined
|
|
111487
|
+
/** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
|
|
111488
|
+
allow_bridge_replacement?: boolean | undefined
|
|
111390
111489
|
}
|
|
111391
111490
|
| undefined
|
|
111392
111491
|
}
|
|
@@ -115828,6 +115927,21 @@ export type Routes = {
|
|
|
115828
115927
|
jsonResponse: {}
|
|
115829
115928
|
maxDuration: undefined
|
|
115830
115929
|
}
|
|
115930
|
+
'/seam/customer/v1/connected_accounts/replace_bridge': {
|
|
115931
|
+
route: '/seam/customer/v1/connected_accounts/replace_bridge'
|
|
115932
|
+
method: 'POST'
|
|
115933
|
+
queryParams: {}
|
|
115934
|
+
jsonBody: {
|
|
115935
|
+
/** ID of the connected account whose Seam Bridge you want to replace. */
|
|
115936
|
+
connected_account_id: string
|
|
115937
|
+
/** Pairing code shown in the new Seam Bridge app. */
|
|
115938
|
+
pairing_code: string
|
|
115939
|
+
}
|
|
115940
|
+
commonParams: {}
|
|
115941
|
+
formData: {}
|
|
115942
|
+
jsonResponse: {}
|
|
115943
|
+
maxDuration: undefined
|
|
115944
|
+
}
|
|
115831
115945
|
'/seam/customer/v1/connector_customers/list': {
|
|
115832
115946
|
route: '/seam/customer/v1/connector_customers/list'
|
|
115833
115947
|
method: 'GET' | 'POST'
|
|
@@ -121204,6 +121318,8 @@ export type Routes = {
|
|
|
121204
121318
|
allow_instant_key_customization?: boolean
|
|
121205
121319
|
/** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
|
|
121206
121320
|
allow_notification_customization?: boolean
|
|
121321
|
+
/** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
|
|
121322
|
+
allow_bridge_replacement?: boolean
|
|
121207
121323
|
}
|
|
121208
121324
|
}
|
|
121209
121325
|
/** Whether the portal is embedded in another application. */
|
|
@@ -121562,6 +121678,8 @@ export type Routes = {
|
|
|
121562
121678
|
allow_instant_key_customization?: boolean | undefined
|
|
121563
121679
|
/** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
|
|
121564
121680
|
allow_notification_customization?: boolean | undefined
|
|
121681
|
+
/** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
|
|
121682
|
+
allow_bridge_replacement?: boolean | undefined
|
|
121565
121683
|
}
|
|
121566
121684
|
| undefined
|
|
121567
121685
|
}
|
|
@@ -128614,58 +128732,9 @@ export type Routes = {
|
|
|
128614
128732
|
* @deprecated use offline_access_codes_enabled*/
|
|
128615
128733
|
supports_offline_access_codes?: boolean | undefined
|
|
128616
128734
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
128617
|
-
noise_level_decibels?:
|
|
128735
|
+
noise_level_decibels?: number | undefined
|
|
128618
128736
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
128619
128737
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
128620
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
128621
|
-
noise_level_nrs?: (number | null) | undefined
|
|
128622
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128623
|
-
co2_ppm?: (number | null) | undefined
|
|
128624
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128625
|
-
co_ppm?: (number | null) | undefined
|
|
128626
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
128627
|
-
air_quality_index?: (number | null) | undefined
|
|
128628
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
128629
|
-
mold_risk_level?: (string | null) | undefined
|
|
128630
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
128631
|
-
is_occupied?: (boolean | null) | undefined
|
|
128632
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
128633
|
-
occupant_count?: (number | null) | undefined
|
|
128634
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
128635
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
128636
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
128637
|
-
named_sensors?:
|
|
128638
|
-
| {
|
|
128639
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
128640
|
-
sensor_name: string
|
|
128641
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
128642
|
-
display_name: string
|
|
128643
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
128644
|
-
temperature_celsius?: (number | null) | undefined
|
|
128645
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
128646
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
128647
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
128648
|
-
relative_humidity?: (number | null) | undefined
|
|
128649
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
128650
|
-
noise_level_decibels?: (number | null) | undefined
|
|
128651
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
128652
|
-
noise_level_nrs?: (number | null) | undefined
|
|
128653
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128654
|
-
co2_ppm?: (number | null) | undefined
|
|
128655
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128656
|
-
co_ppm?: (number | null) | undefined
|
|
128657
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
128658
|
-
air_quality_index?: (number | null) | undefined
|
|
128659
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
128660
|
-
mold_risk_level?: (string | null) | undefined
|
|
128661
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
128662
|
-
is_occupied?: (boolean | null) | undefined
|
|
128663
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
128664
|
-
occupant_count?: (number | null) | undefined
|
|
128665
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
128666
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
128667
|
-
}[]
|
|
128668
|
-
| undefined
|
|
128669
128738
|
} & {
|
|
128670
128739
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
128671
128740
|
assa_abloy_credential_service_metadata?:
|
|
@@ -129758,11 +129827,11 @@ export type Routes = {
|
|
|
129758
129827
|
| undefined
|
|
129759
129828
|
} & {
|
|
129760
129829
|
/** Reported temperature in °F. */
|
|
129761
|
-
temperature_fahrenheit?:
|
|
129830
|
+
temperature_fahrenheit?: number | undefined
|
|
129762
129831
|
/** Reported temperature in °C. */
|
|
129763
|
-
temperature_celsius?:
|
|
129832
|
+
temperature_celsius?: number | undefined
|
|
129764
129833
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
129765
|
-
relative_humidity?:
|
|
129834
|
+
relative_humidity?: number | undefined
|
|
129766
129835
|
/** HVAC mode settings that the thermostat supports. */
|
|
129767
129836
|
available_hvac_mode_settings?:
|
|
129768
129837
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -130597,6 +130666,63 @@ export type Routes = {
|
|
|
130597
130666
|
image_url?: string | undefined
|
|
130598
130667
|
}
|
|
130599
130668
|
| undefined
|
|
130669
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
130670
|
+
temperature_celsius?: number | undefined
|
|
130671
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
130672
|
+
temperature_fahrenheit?: number | undefined
|
|
130673
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
130674
|
+
relative_humidity?: number | undefined
|
|
130675
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
130676
|
+
noise_level_decibels?: number | undefined
|
|
130677
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
130678
|
+
noise_level_nrs?: number | undefined
|
|
130679
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
130680
|
+
co2_ppm?: number | undefined
|
|
130681
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
130682
|
+
co_ppm?: number | undefined
|
|
130683
|
+
/** Air quality index, if the device measures it. */
|
|
130684
|
+
air_quality_index?: number | undefined
|
|
130685
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
130686
|
+
mold_risk_level?: string | undefined
|
|
130687
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
130688
|
+
is_occupied?: boolean | undefined
|
|
130689
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
130690
|
+
occupant_count?: number | undefined
|
|
130691
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
130692
|
+
is_smoking_detected?: boolean | undefined
|
|
130693
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
130694
|
+
named_sensors?:
|
|
130695
|
+
| {
|
|
130696
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
130697
|
+
sensor_name: string
|
|
130698
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
130699
|
+
display_name: string
|
|
130700
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
130701
|
+
temperature_celsius?: number | undefined
|
|
130702
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
130703
|
+
temperature_fahrenheit?: number | undefined
|
|
130704
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
130705
|
+
relative_humidity?: number | undefined
|
|
130706
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
130707
|
+
noise_level_decibels?: number | undefined
|
|
130708
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
130709
|
+
noise_level_nrs?: number | undefined
|
|
130710
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
130711
|
+
co2_ppm?: number | undefined
|
|
130712
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
130713
|
+
co_ppm?: number | undefined
|
|
130714
|
+
/** Air quality index, if the device measures it. */
|
|
130715
|
+
air_quality_index?: number | undefined
|
|
130716
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
130717
|
+
mold_risk_level?: string | undefined
|
|
130718
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
130719
|
+
is_occupied?: boolean | undefined
|
|
130720
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
130721
|
+
occupant_count?: number | undefined
|
|
130722
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
130723
|
+
is_smoking_detected?: boolean | undefined
|
|
130724
|
+
}[]
|
|
130725
|
+
| undefined
|
|
130600
130726
|
/** Indicates whether the device supports remote unlocking. */
|
|
130601
130727
|
can_remotely_unlock?: boolean | undefined
|
|
130602
130728
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -162730,58 +162856,9 @@ export type Routes = {
|
|
|
162730
162856
|
* @deprecated use offline_access_codes_enabled*/
|
|
162731
162857
|
supports_offline_access_codes?: boolean | undefined
|
|
162732
162858
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
162733
|
-
noise_level_decibels?:
|
|
162859
|
+
noise_level_decibels?: number | undefined
|
|
162734
162860
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
162735
162861
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
162736
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
162737
|
-
noise_level_nrs?: (number | null) | undefined
|
|
162738
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162739
|
-
co2_ppm?: (number | null) | undefined
|
|
162740
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162741
|
-
co_ppm?: (number | null) | undefined
|
|
162742
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
162743
|
-
air_quality_index?: (number | null) | undefined
|
|
162744
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
162745
|
-
mold_risk_level?: (string | null) | undefined
|
|
162746
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
162747
|
-
is_occupied?: (boolean | null) | undefined
|
|
162748
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
162749
|
-
occupant_count?: (number | null) | undefined
|
|
162750
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
162751
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
162752
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
162753
|
-
named_sensors?:
|
|
162754
|
-
| {
|
|
162755
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
162756
|
-
sensor_name: string
|
|
162757
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
162758
|
-
display_name: string
|
|
162759
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
162760
|
-
temperature_celsius?: (number | null) | undefined
|
|
162761
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
162762
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
162763
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
162764
|
-
relative_humidity?: (number | null) | undefined
|
|
162765
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
162766
|
-
noise_level_decibels?: (number | null) | undefined
|
|
162767
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
162768
|
-
noise_level_nrs?: (number | null) | undefined
|
|
162769
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162770
|
-
co2_ppm?: (number | null) | undefined
|
|
162771
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162772
|
-
co_ppm?: (number | null) | undefined
|
|
162773
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
162774
|
-
air_quality_index?: (number | null) | undefined
|
|
162775
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
162776
|
-
mold_risk_level?: (string | null) | undefined
|
|
162777
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
162778
|
-
is_occupied?: (boolean | null) | undefined
|
|
162779
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
162780
|
-
occupant_count?: (number | null) | undefined
|
|
162781
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
162782
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
162783
|
-
}[]
|
|
162784
|
-
| undefined
|
|
162785
162862
|
} & {
|
|
162786
162863
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
162787
162864
|
assa_abloy_credential_service_metadata?:
|
|
@@ -163839,11 +163916,11 @@ export type Routes = {
|
|
|
163839
163916
|
| undefined
|
|
163840
163917
|
} & {
|
|
163841
163918
|
/** Reported temperature in °F. */
|
|
163842
|
-
temperature_fahrenheit?:
|
|
163919
|
+
temperature_fahrenheit?: number | undefined
|
|
163843
163920
|
/** Reported temperature in °C. */
|
|
163844
|
-
temperature_celsius?:
|
|
163921
|
+
temperature_celsius?: number | undefined
|
|
163845
163922
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
163846
|
-
relative_humidity?:
|
|
163923
|
+
relative_humidity?: number | undefined
|
|
163847
163924
|
/** HVAC mode settings that the thermostat supports. */
|
|
163848
163925
|
available_hvac_mode_settings?:
|
|
163849
163926
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -164656,6 +164733,63 @@ export type Routes = {
|
|
|
164656
164733
|
image_url?: string | undefined
|
|
164657
164734
|
}
|
|
164658
164735
|
| undefined
|
|
164736
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
164737
|
+
temperature_celsius?: number | undefined
|
|
164738
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
164739
|
+
temperature_fahrenheit?: number | undefined
|
|
164740
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
164741
|
+
relative_humidity?: number | undefined
|
|
164742
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
164743
|
+
noise_level_decibels?: number | undefined
|
|
164744
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
164745
|
+
noise_level_nrs?: number | undefined
|
|
164746
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
164747
|
+
co2_ppm?: number | undefined
|
|
164748
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
164749
|
+
co_ppm?: number | undefined
|
|
164750
|
+
/** Air quality index, if the device measures it. */
|
|
164751
|
+
air_quality_index?: number | undefined
|
|
164752
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
164753
|
+
mold_risk_level?: string | undefined
|
|
164754
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
164755
|
+
is_occupied?: boolean | undefined
|
|
164756
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
164757
|
+
occupant_count?: number | undefined
|
|
164758
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
164759
|
+
is_smoking_detected?: boolean | undefined
|
|
164760
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
164761
|
+
named_sensors?:
|
|
164762
|
+
| {
|
|
164763
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
164764
|
+
sensor_name: string
|
|
164765
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
164766
|
+
display_name: string
|
|
164767
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
164768
|
+
temperature_celsius?: number | undefined
|
|
164769
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
164770
|
+
temperature_fahrenheit?: number | undefined
|
|
164771
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
164772
|
+
relative_humidity?: number | undefined
|
|
164773
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
164774
|
+
noise_level_decibels?: number | undefined
|
|
164775
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
164776
|
+
noise_level_nrs?: number | undefined
|
|
164777
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
164778
|
+
co2_ppm?: number | undefined
|
|
164779
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
164780
|
+
co_ppm?: number | undefined
|
|
164781
|
+
/** Air quality index, if the device measures it. */
|
|
164782
|
+
air_quality_index?: number | undefined
|
|
164783
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
164784
|
+
mold_risk_level?: string | undefined
|
|
164785
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
164786
|
+
is_occupied?: boolean | undefined
|
|
164787
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
164788
|
+
occupant_count?: number | undefined
|
|
164789
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
164790
|
+
is_smoking_detected?: boolean | undefined
|
|
164791
|
+
}[]
|
|
164792
|
+
| undefined
|
|
164659
164793
|
/** Indicates whether the device supports remote unlocking. */
|
|
164660
164794
|
can_remotely_unlock?: boolean | undefined
|
|
164661
164795
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -170045,58 +170179,9 @@ export type Routes = {
|
|
|
170045
170179
|
* @deprecated use offline_access_codes_enabled*/
|
|
170046
170180
|
supports_offline_access_codes?: boolean | undefined
|
|
170047
170181
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
170048
|
-
noise_level_decibels?:
|
|
170182
|
+
noise_level_decibels?: number | undefined
|
|
170049
170183
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
170050
170184
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
170051
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
170052
|
-
noise_level_nrs?: (number | null) | undefined
|
|
170053
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
170054
|
-
co2_ppm?: (number | null) | undefined
|
|
170055
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
170056
|
-
co_ppm?: (number | null) | undefined
|
|
170057
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
170058
|
-
air_quality_index?: (number | null) | undefined
|
|
170059
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
170060
|
-
mold_risk_level?: (string | null) | undefined
|
|
170061
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
170062
|
-
is_occupied?: (boolean | null) | undefined
|
|
170063
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
170064
|
-
occupant_count?: (number | null) | undefined
|
|
170065
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
170066
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
170067
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
170068
|
-
named_sensors?:
|
|
170069
|
-
| {
|
|
170070
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
170071
|
-
sensor_name: string
|
|
170072
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
170073
|
-
display_name: string
|
|
170074
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
170075
|
-
temperature_celsius?: (number | null) | undefined
|
|
170076
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
170077
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
170078
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
170079
|
-
relative_humidity?: (number | null) | undefined
|
|
170080
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
170081
|
-
noise_level_decibels?: (number | null) | undefined
|
|
170082
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
170083
|
-
noise_level_nrs?: (number | null) | undefined
|
|
170084
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
170085
|
-
co2_ppm?: (number | null) | undefined
|
|
170086
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
170087
|
-
co_ppm?: (number | null) | undefined
|
|
170088
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
170089
|
-
air_quality_index?: (number | null) | undefined
|
|
170090
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
170091
|
-
mold_risk_level?: (string | null) | undefined
|
|
170092
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
170093
|
-
is_occupied?: (boolean | null) | undefined
|
|
170094
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
170095
|
-
occupant_count?: (number | null) | undefined
|
|
170096
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
170097
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
170098
|
-
}[]
|
|
170099
|
-
| undefined
|
|
170100
170185
|
} & {
|
|
170101
170186
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
170102
170187
|
assa_abloy_credential_service_metadata?:
|
|
@@ -171154,11 +171239,11 @@ export type Routes = {
|
|
|
171154
171239
|
| undefined
|
|
171155
171240
|
} & {
|
|
171156
171241
|
/** Reported temperature in °F. */
|
|
171157
|
-
temperature_fahrenheit?:
|
|
171242
|
+
temperature_fahrenheit?: number | undefined
|
|
171158
171243
|
/** Reported temperature in °C. */
|
|
171159
|
-
temperature_celsius?:
|
|
171244
|
+
temperature_celsius?: number | undefined
|
|
171160
171245
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
171161
|
-
relative_humidity?:
|
|
171246
|
+
relative_humidity?: number | undefined
|
|
171162
171247
|
/** HVAC mode settings that the thermostat supports. */
|
|
171163
171248
|
available_hvac_mode_settings?:
|
|
171164
171249
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -171971,6 +172056,63 @@ export type Routes = {
|
|
|
171971
172056
|
image_url?: string | undefined
|
|
171972
172057
|
}
|
|
171973
172058
|
| undefined
|
|
172059
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
172060
|
+
temperature_celsius?: number | undefined
|
|
172061
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
172062
|
+
temperature_fahrenheit?: number | undefined
|
|
172063
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
172064
|
+
relative_humidity?: number | undefined
|
|
172065
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
172066
|
+
noise_level_decibels?: number | undefined
|
|
172067
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
172068
|
+
noise_level_nrs?: number | undefined
|
|
172069
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
172070
|
+
co2_ppm?: number | undefined
|
|
172071
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
172072
|
+
co_ppm?: number | undefined
|
|
172073
|
+
/** Air quality index, if the device measures it. */
|
|
172074
|
+
air_quality_index?: number | undefined
|
|
172075
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
172076
|
+
mold_risk_level?: string | undefined
|
|
172077
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
172078
|
+
is_occupied?: boolean | undefined
|
|
172079
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
172080
|
+
occupant_count?: number | undefined
|
|
172081
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
172082
|
+
is_smoking_detected?: boolean | undefined
|
|
172083
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
172084
|
+
named_sensors?:
|
|
172085
|
+
| {
|
|
172086
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
172087
|
+
sensor_name: string
|
|
172088
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
172089
|
+
display_name: string
|
|
172090
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
172091
|
+
temperature_celsius?: number | undefined
|
|
172092
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
172093
|
+
temperature_fahrenheit?: number | undefined
|
|
172094
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
172095
|
+
relative_humidity?: number | undefined
|
|
172096
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
172097
|
+
noise_level_decibels?: number | undefined
|
|
172098
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
172099
|
+
noise_level_nrs?: number | undefined
|
|
172100
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
172101
|
+
co2_ppm?: number | undefined
|
|
172102
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
172103
|
+
co_ppm?: number | undefined
|
|
172104
|
+
/** Air quality index, if the device measures it. */
|
|
172105
|
+
air_quality_index?: number | undefined
|
|
172106
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
172107
|
+
mold_risk_level?: string | undefined
|
|
172108
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
172109
|
+
is_occupied?: boolean | undefined
|
|
172110
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
172111
|
+
occupant_count?: number | undefined
|
|
172112
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
172113
|
+
is_smoking_detected?: boolean | undefined
|
|
172114
|
+
}[]
|
|
172115
|
+
| undefined
|
|
171974
172116
|
/** Indicates whether the device supports remote unlocking. */
|
|
171975
172117
|
can_remotely_unlock?: boolean | undefined
|
|
171976
172118
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -172203,58 +172345,9 @@ export type Routes = {
|
|
|
172203
172345
|
* @deprecated use offline_access_codes_enabled*/
|
|
172204
172346
|
supports_offline_access_codes?: boolean | undefined
|
|
172205
172347
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
172206
|
-
noise_level_decibels?:
|
|
172348
|
+
noise_level_decibels?: number | undefined
|
|
172207
172349
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
172208
172350
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
172209
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
172210
|
-
noise_level_nrs?: (number | null) | undefined
|
|
172211
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
172212
|
-
co2_ppm?: (number | null) | undefined
|
|
172213
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
172214
|
-
co_ppm?: (number | null) | undefined
|
|
172215
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
172216
|
-
air_quality_index?: (number | null) | undefined
|
|
172217
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
172218
|
-
mold_risk_level?: (string | null) | undefined
|
|
172219
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
172220
|
-
is_occupied?: (boolean | null) | undefined
|
|
172221
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
172222
|
-
occupant_count?: (number | null) | undefined
|
|
172223
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
172224
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
172225
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
172226
|
-
named_sensors?:
|
|
172227
|
-
| {
|
|
172228
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
172229
|
-
sensor_name: string
|
|
172230
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
172231
|
-
display_name: string
|
|
172232
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
172233
|
-
temperature_celsius?: (number | null) | undefined
|
|
172234
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
172235
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
172236
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
172237
|
-
relative_humidity?: (number | null) | undefined
|
|
172238
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
172239
|
-
noise_level_decibels?: (number | null) | undefined
|
|
172240
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
172241
|
-
noise_level_nrs?: (number | null) | undefined
|
|
172242
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
172243
|
-
co2_ppm?: (number | null) | undefined
|
|
172244
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
172245
|
-
co_ppm?: (number | null) | undefined
|
|
172246
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
172247
|
-
air_quality_index?: (number | null) | undefined
|
|
172248
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
172249
|
-
mold_risk_level?: (string | null) | undefined
|
|
172250
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
172251
|
-
is_occupied?: (boolean | null) | undefined
|
|
172252
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
172253
|
-
occupant_count?: (number | null) | undefined
|
|
172254
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
172255
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
172256
|
-
}[]
|
|
172257
|
-
| undefined
|
|
172258
172351
|
} & {
|
|
172259
172352
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
172260
172353
|
assa_abloy_credential_service_metadata?:
|
|
@@ -173312,11 +173405,11 @@ export type Routes = {
|
|
|
173312
173405
|
| undefined
|
|
173313
173406
|
} & {
|
|
173314
173407
|
/** Reported temperature in °F. */
|
|
173315
|
-
temperature_fahrenheit?:
|
|
173408
|
+
temperature_fahrenheit?: number | undefined
|
|
173316
173409
|
/** Reported temperature in °C. */
|
|
173317
|
-
temperature_celsius?:
|
|
173410
|
+
temperature_celsius?: number | undefined
|
|
173318
173411
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
173319
|
-
relative_humidity?:
|
|
173412
|
+
relative_humidity?: number | undefined
|
|
173320
173413
|
/** HVAC mode settings that the thermostat supports. */
|
|
173321
173414
|
available_hvac_mode_settings?:
|
|
173322
173415
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -174129,6 +174222,63 @@ export type Routes = {
|
|
|
174129
174222
|
image_url?: string | undefined
|
|
174130
174223
|
}
|
|
174131
174224
|
| undefined
|
|
174225
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
174226
|
+
temperature_celsius?: number | undefined
|
|
174227
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
174228
|
+
temperature_fahrenheit?: number | undefined
|
|
174229
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
174230
|
+
relative_humidity?: number | undefined
|
|
174231
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
174232
|
+
noise_level_decibels?: number | undefined
|
|
174233
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
174234
|
+
noise_level_nrs?: number | undefined
|
|
174235
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
174236
|
+
co2_ppm?: number | undefined
|
|
174237
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
174238
|
+
co_ppm?: number | undefined
|
|
174239
|
+
/** Air quality index, if the device measures it. */
|
|
174240
|
+
air_quality_index?: number | undefined
|
|
174241
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
174242
|
+
mold_risk_level?: string | undefined
|
|
174243
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
174244
|
+
is_occupied?: boolean | undefined
|
|
174245
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
174246
|
+
occupant_count?: number | undefined
|
|
174247
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
174248
|
+
is_smoking_detected?: boolean | undefined
|
|
174249
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
174250
|
+
named_sensors?:
|
|
174251
|
+
| {
|
|
174252
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
174253
|
+
sensor_name: string
|
|
174254
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
174255
|
+
display_name: string
|
|
174256
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
174257
|
+
temperature_celsius?: number | undefined
|
|
174258
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
174259
|
+
temperature_fahrenheit?: number | undefined
|
|
174260
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
174261
|
+
relative_humidity?: number | undefined
|
|
174262
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
174263
|
+
noise_level_decibels?: number | undefined
|
|
174264
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
174265
|
+
noise_level_nrs?: number | undefined
|
|
174266
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
174267
|
+
co2_ppm?: number | undefined
|
|
174268
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
174269
|
+
co_ppm?: number | undefined
|
|
174270
|
+
/** Air quality index, if the device measures it. */
|
|
174271
|
+
air_quality_index?: number | undefined
|
|
174272
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
174273
|
+
mold_risk_level?: string | undefined
|
|
174274
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
174275
|
+
is_occupied?: boolean | undefined
|
|
174276
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
174277
|
+
occupant_count?: number | undefined
|
|
174278
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
174279
|
+
is_smoking_detected?: boolean | undefined
|
|
174280
|
+
}[]
|
|
174281
|
+
| undefined
|
|
174132
174282
|
/** Indicates whether the device supports remote unlocking. */
|
|
174133
174283
|
can_remotely_unlock?: boolean | undefined
|
|
174134
174284
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -185728,58 +185878,9 @@ export type Routes = {
|
|
|
185728
185878
|
* @deprecated use offline_access_codes_enabled*/
|
|
185729
185879
|
supports_offline_access_codes?: boolean | undefined
|
|
185730
185880
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
185731
|
-
noise_level_decibels?:
|
|
185881
|
+
noise_level_decibels?: number | undefined
|
|
185732
185882
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
185733
185883
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
185734
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
185735
|
-
noise_level_nrs?: (number | null) | undefined
|
|
185736
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185737
|
-
co2_ppm?: (number | null) | undefined
|
|
185738
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185739
|
-
co_ppm?: (number | null) | undefined
|
|
185740
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
185741
|
-
air_quality_index?: (number | null) | undefined
|
|
185742
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
185743
|
-
mold_risk_level?: (string | null) | undefined
|
|
185744
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
185745
|
-
is_occupied?: (boolean | null) | undefined
|
|
185746
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
185747
|
-
occupant_count?: (number | null) | undefined
|
|
185748
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
185749
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
185750
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
185751
|
-
named_sensors?:
|
|
185752
|
-
| {
|
|
185753
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
185754
|
-
sensor_name: string
|
|
185755
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
185756
|
-
display_name: string
|
|
185757
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
185758
|
-
temperature_celsius?: (number | null) | undefined
|
|
185759
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
185760
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
185761
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
185762
|
-
relative_humidity?: (number | null) | undefined
|
|
185763
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
185764
|
-
noise_level_decibels?: (number | null) | undefined
|
|
185765
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
185766
|
-
noise_level_nrs?: (number | null) | undefined
|
|
185767
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185768
|
-
co2_ppm?: (number | null) | undefined
|
|
185769
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185770
|
-
co_ppm?: (number | null) | undefined
|
|
185771
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
185772
|
-
air_quality_index?: (number | null) | undefined
|
|
185773
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
185774
|
-
mold_risk_level?: (string | null) | undefined
|
|
185775
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
185776
|
-
is_occupied?: (boolean | null) | undefined
|
|
185777
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
185778
|
-
occupant_count?: (number | null) | undefined
|
|
185779
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
185780
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
185781
|
-
}[]
|
|
185782
|
-
| undefined
|
|
185783
185884
|
} & {
|
|
185784
185885
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
185785
185886
|
assa_abloy_credential_service_metadata?:
|
|
@@ -186837,11 +186938,11 @@ export type Routes = {
|
|
|
186837
186938
|
| undefined
|
|
186838
186939
|
} & {
|
|
186839
186940
|
/** Reported temperature in °F. */
|
|
186840
|
-
temperature_fahrenheit?:
|
|
186941
|
+
temperature_fahrenheit?: number | undefined
|
|
186841
186942
|
/** Reported temperature in °C. */
|
|
186842
|
-
temperature_celsius?:
|
|
186943
|
+
temperature_celsius?: number | undefined
|
|
186843
186944
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
186844
|
-
relative_humidity?:
|
|
186945
|
+
relative_humidity?: number | undefined
|
|
186845
186946
|
/** HVAC mode settings that the thermostat supports. */
|
|
186846
186947
|
available_hvac_mode_settings?:
|
|
186847
186948
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -187654,6 +187755,63 @@ export type Routes = {
|
|
|
187654
187755
|
image_url?: string | undefined
|
|
187655
187756
|
}
|
|
187656
187757
|
| undefined
|
|
187758
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
187759
|
+
temperature_celsius?: number | undefined
|
|
187760
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
187761
|
+
temperature_fahrenheit?: number | undefined
|
|
187762
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
187763
|
+
relative_humidity?: number | undefined
|
|
187764
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
187765
|
+
noise_level_decibels?: number | undefined
|
|
187766
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
187767
|
+
noise_level_nrs?: number | undefined
|
|
187768
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
187769
|
+
co2_ppm?: number | undefined
|
|
187770
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
187771
|
+
co_ppm?: number | undefined
|
|
187772
|
+
/** Air quality index, if the device measures it. */
|
|
187773
|
+
air_quality_index?: number | undefined
|
|
187774
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
187775
|
+
mold_risk_level?: string | undefined
|
|
187776
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
187777
|
+
is_occupied?: boolean | undefined
|
|
187778
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
187779
|
+
occupant_count?: number | undefined
|
|
187780
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
187781
|
+
is_smoking_detected?: boolean | undefined
|
|
187782
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
187783
|
+
named_sensors?:
|
|
187784
|
+
| {
|
|
187785
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
187786
|
+
sensor_name: string
|
|
187787
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
187788
|
+
display_name: string
|
|
187789
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
187790
|
+
temperature_celsius?: number | undefined
|
|
187791
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
187792
|
+
temperature_fahrenheit?: number | undefined
|
|
187793
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
187794
|
+
relative_humidity?: number | undefined
|
|
187795
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
187796
|
+
noise_level_decibels?: number | undefined
|
|
187797
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
187798
|
+
noise_level_nrs?: number | undefined
|
|
187799
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
187800
|
+
co2_ppm?: number | undefined
|
|
187801
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
187802
|
+
co_ppm?: number | undefined
|
|
187803
|
+
/** Air quality index, if the device measures it. */
|
|
187804
|
+
air_quality_index?: number | undefined
|
|
187805
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
187806
|
+
mold_risk_level?: string | undefined
|
|
187807
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
187808
|
+
is_occupied?: boolean | undefined
|
|
187809
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
187810
|
+
occupant_count?: number | undefined
|
|
187811
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
187812
|
+
is_smoking_detected?: boolean | undefined
|
|
187813
|
+
}[]
|
|
187814
|
+
| undefined
|
|
187657
187815
|
/** Indicates whether the device supports remote unlocking. */
|
|
187658
187816
|
can_remotely_unlock?: boolean | undefined
|
|
187659
187817
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -187888,58 +188046,9 @@ export type Routes = {
|
|
|
187888
188046
|
* @deprecated use offline_access_codes_enabled*/
|
|
187889
188047
|
supports_offline_access_codes?: boolean | undefined
|
|
187890
188048
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
187891
|
-
noise_level_decibels?:
|
|
188049
|
+
noise_level_decibels?: number | undefined
|
|
187892
188050
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
187893
188051
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
187894
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
187895
|
-
noise_level_nrs?: (number | null) | undefined
|
|
187896
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187897
|
-
co2_ppm?: (number | null) | undefined
|
|
187898
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187899
|
-
co_ppm?: (number | null) | undefined
|
|
187900
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
187901
|
-
air_quality_index?: (number | null) | undefined
|
|
187902
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
187903
|
-
mold_risk_level?: (string | null) | undefined
|
|
187904
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
187905
|
-
is_occupied?: (boolean | null) | undefined
|
|
187906
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
187907
|
-
occupant_count?: (number | null) | undefined
|
|
187908
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
187909
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
187910
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
187911
|
-
named_sensors?:
|
|
187912
|
-
| {
|
|
187913
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
187914
|
-
sensor_name: string
|
|
187915
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
187916
|
-
display_name: string
|
|
187917
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
187918
|
-
temperature_celsius?: (number | null) | undefined
|
|
187919
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
187920
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
187921
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
187922
|
-
relative_humidity?: (number | null) | undefined
|
|
187923
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
187924
|
-
noise_level_decibels?: (number | null) | undefined
|
|
187925
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
187926
|
-
noise_level_nrs?: (number | null) | undefined
|
|
187927
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187928
|
-
co2_ppm?: (number | null) | undefined
|
|
187929
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187930
|
-
co_ppm?: (number | null) | undefined
|
|
187931
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
187932
|
-
air_quality_index?: (number | null) | undefined
|
|
187933
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
187934
|
-
mold_risk_level?: (string | null) | undefined
|
|
187935
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
187936
|
-
is_occupied?: (boolean | null) | undefined
|
|
187937
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
187938
|
-
occupant_count?: (number | null) | undefined
|
|
187939
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
187940
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
187941
|
-
}[]
|
|
187942
|
-
| undefined
|
|
187943
188052
|
} & {
|
|
187944
188053
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
187945
188054
|
assa_abloy_credential_service_metadata?:
|
|
@@ -188997,11 +189106,11 @@ export type Routes = {
|
|
|
188997
189106
|
| undefined
|
|
188998
189107
|
} & {
|
|
188999
189108
|
/** Reported temperature in °F. */
|
|
189000
|
-
temperature_fahrenheit?:
|
|
189109
|
+
temperature_fahrenheit?: number | undefined
|
|
189001
189110
|
/** Reported temperature in °C. */
|
|
189002
|
-
temperature_celsius?:
|
|
189111
|
+
temperature_celsius?: number | undefined
|
|
189003
189112
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
189004
|
-
relative_humidity?:
|
|
189113
|
+
relative_humidity?: number | undefined
|
|
189005
189114
|
/** HVAC mode settings that the thermostat supports. */
|
|
189006
189115
|
available_hvac_mode_settings?:
|
|
189007
189116
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -189814,6 +189923,63 @@ export type Routes = {
|
|
|
189814
189923
|
image_url?: string | undefined
|
|
189815
189924
|
}
|
|
189816
189925
|
| undefined
|
|
189926
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
189927
|
+
temperature_celsius?: number | undefined
|
|
189928
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
189929
|
+
temperature_fahrenheit?: number | undefined
|
|
189930
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
189931
|
+
relative_humidity?: number | undefined
|
|
189932
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
189933
|
+
noise_level_decibels?: number | undefined
|
|
189934
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
189935
|
+
noise_level_nrs?: number | undefined
|
|
189936
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
189937
|
+
co2_ppm?: number | undefined
|
|
189938
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
189939
|
+
co_ppm?: number | undefined
|
|
189940
|
+
/** Air quality index, if the device measures it. */
|
|
189941
|
+
air_quality_index?: number | undefined
|
|
189942
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
189943
|
+
mold_risk_level?: string | undefined
|
|
189944
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
189945
|
+
is_occupied?: boolean | undefined
|
|
189946
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
189947
|
+
occupant_count?: number | undefined
|
|
189948
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
189949
|
+
is_smoking_detected?: boolean | undefined
|
|
189950
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
189951
|
+
named_sensors?:
|
|
189952
|
+
| {
|
|
189953
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
189954
|
+
sensor_name: string
|
|
189955
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
189956
|
+
display_name: string
|
|
189957
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
189958
|
+
temperature_celsius?: number | undefined
|
|
189959
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
189960
|
+
temperature_fahrenheit?: number | undefined
|
|
189961
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
189962
|
+
relative_humidity?: number | undefined
|
|
189963
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
189964
|
+
noise_level_decibels?: number | undefined
|
|
189965
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
189966
|
+
noise_level_nrs?: number | undefined
|
|
189967
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
189968
|
+
co2_ppm?: number | undefined
|
|
189969
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
189970
|
+
co_ppm?: number | undefined
|
|
189971
|
+
/** Air quality index, if the device measures it. */
|
|
189972
|
+
air_quality_index?: number | undefined
|
|
189973
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
189974
|
+
mold_risk_level?: string | undefined
|
|
189975
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
189976
|
+
is_occupied?: boolean | undefined
|
|
189977
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
189978
|
+
occupant_count?: number | undefined
|
|
189979
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
189980
|
+
is_smoking_detected?: boolean | undefined
|
|
189981
|
+
}[]
|
|
189982
|
+
| undefined
|
|
189817
189983
|
/** Indicates whether the device supports remote unlocking. */
|
|
189818
189984
|
can_remotely_unlock?: boolean | undefined
|
|
189819
189985
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -191382,6 +191548,8 @@ export type Routes = {
|
|
|
191382
191548
|
allow_instant_key_customization?: boolean | undefined
|
|
191383
191549
|
/** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
|
|
191384
191550
|
allow_notification_customization?: boolean | undefined
|
|
191551
|
+
/** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
|
|
191552
|
+
allow_bridge_replacement?: boolean | undefined
|
|
191385
191553
|
}
|
|
191386
191554
|
| undefined
|
|
191387
191555
|
}
|
|
@@ -191646,6 +191814,8 @@ export type Routes = {
|
|
|
191646
191814
|
allow_instant_key_customization?: boolean | undefined
|
|
191647
191815
|
/** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
|
|
191648
191816
|
allow_notification_customization?: boolean | undefined
|
|
191817
|
+
/** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
|
|
191818
|
+
allow_bridge_replacement?: boolean | undefined
|
|
191649
191819
|
}
|
|
191650
191820
|
| undefined
|
|
191651
191821
|
}
|
|
@@ -191920,6 +192090,8 @@ export type Routes = {
|
|
|
191920
192090
|
allow_instant_key_customization?: boolean | undefined
|
|
191921
192091
|
/** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
|
|
191922
192092
|
allow_notification_customization?: boolean | undefined
|
|
192093
|
+
/** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
|
|
192094
|
+
allow_bridge_replacement?: boolean | undefined
|
|
191923
192095
|
}
|
|
191924
192096
|
| undefined
|
|
191925
192097
|
}
|
|
@@ -192194,6 +192366,8 @@ export type Routes = {
|
|
|
192194
192366
|
allow_instant_key_customization?: boolean | undefined
|
|
192195
192367
|
/** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
|
|
192196
192368
|
allow_notification_customization?: boolean | undefined
|
|
192369
|
+
/** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
|
|
192370
|
+
allow_bridge_replacement?: boolean | undefined
|
|
192197
192371
|
}
|
|
192198
192372
|
| undefined
|
|
192199
192373
|
}
|
|
@@ -192464,6 +192638,8 @@ export type Routes = {
|
|
|
192464
192638
|
allow_instant_key_customization?: boolean | undefined
|
|
192465
192639
|
/** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
|
|
192466
192640
|
allow_notification_customization?: boolean | undefined
|
|
192641
|
+
/** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
|
|
192642
|
+
allow_bridge_replacement?: boolean | undefined
|
|
192467
192643
|
}
|
|
192468
192644
|
| undefined
|
|
192469
192645
|
}
|
|
@@ -192763,58 +192939,9 @@ export type Routes = {
|
|
|
192763
192939
|
* @deprecated use offline_access_codes_enabled*/
|
|
192764
192940
|
supports_offline_access_codes?: boolean | undefined
|
|
192765
192941
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
192766
|
-
noise_level_decibels?:
|
|
192942
|
+
noise_level_decibels?: number | undefined
|
|
192767
192943
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
192768
192944
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
192769
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
192770
|
-
noise_level_nrs?: (number | null) | undefined
|
|
192771
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192772
|
-
co2_ppm?: (number | null) | undefined
|
|
192773
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192774
|
-
co_ppm?: (number | null) | undefined
|
|
192775
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
192776
|
-
air_quality_index?: (number | null) | undefined
|
|
192777
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
192778
|
-
mold_risk_level?: (string | null) | undefined
|
|
192779
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
192780
|
-
is_occupied?: (boolean | null) | undefined
|
|
192781
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
192782
|
-
occupant_count?: (number | null) | undefined
|
|
192783
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
192784
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
192785
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
192786
|
-
named_sensors?:
|
|
192787
|
-
| {
|
|
192788
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
192789
|
-
sensor_name: string
|
|
192790
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
192791
|
-
display_name: string
|
|
192792
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
192793
|
-
temperature_celsius?: (number | null) | undefined
|
|
192794
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
192795
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
192796
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
192797
|
-
relative_humidity?: (number | null) | undefined
|
|
192798
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
192799
|
-
noise_level_decibels?: (number | null) | undefined
|
|
192800
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
192801
|
-
noise_level_nrs?: (number | null) | undefined
|
|
192802
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192803
|
-
co2_ppm?: (number | null) | undefined
|
|
192804
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192805
|
-
co_ppm?: (number | null) | undefined
|
|
192806
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
192807
|
-
air_quality_index?: (number | null) | undefined
|
|
192808
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
192809
|
-
mold_risk_level?: (string | null) | undefined
|
|
192810
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
192811
|
-
is_occupied?: (boolean | null) | undefined
|
|
192812
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
192813
|
-
occupant_count?: (number | null) | undefined
|
|
192814
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
192815
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
192816
|
-
}[]
|
|
192817
|
-
| undefined
|
|
192818
192945
|
} & {
|
|
192819
192946
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
192820
192947
|
assa_abloy_credential_service_metadata?:
|
|
@@ -193907,11 +194034,11 @@ export type Routes = {
|
|
|
193907
194034
|
| undefined
|
|
193908
194035
|
} & {
|
|
193909
194036
|
/** Reported temperature in °F. */
|
|
193910
|
-
temperature_fahrenheit?:
|
|
194037
|
+
temperature_fahrenheit?: number | undefined
|
|
193911
194038
|
/** Reported temperature in °C. */
|
|
193912
|
-
temperature_celsius?:
|
|
194039
|
+
temperature_celsius?: number | undefined
|
|
193913
194040
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
193914
|
-
relative_humidity?:
|
|
194041
|
+
relative_humidity?: number | undefined
|
|
193915
194042
|
/** HVAC mode settings that the thermostat supports. */
|
|
193916
194043
|
available_hvac_mode_settings?:
|
|
193917
194044
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -194746,6 +194873,63 @@ export type Routes = {
|
|
|
194746
194873
|
image_url?: string | undefined
|
|
194747
194874
|
}
|
|
194748
194875
|
| undefined
|
|
194876
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
194877
|
+
temperature_celsius?: number | undefined
|
|
194878
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
194879
|
+
temperature_fahrenheit?: number | undefined
|
|
194880
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
194881
|
+
relative_humidity?: number | undefined
|
|
194882
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
194883
|
+
noise_level_decibels?: number | undefined
|
|
194884
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
194885
|
+
noise_level_nrs?: number | undefined
|
|
194886
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
194887
|
+
co2_ppm?: number | undefined
|
|
194888
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
194889
|
+
co_ppm?: number | undefined
|
|
194890
|
+
/** Air quality index, if the device measures it. */
|
|
194891
|
+
air_quality_index?: number | undefined
|
|
194892
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
194893
|
+
mold_risk_level?: string | undefined
|
|
194894
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
194895
|
+
is_occupied?: boolean | undefined
|
|
194896
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
194897
|
+
occupant_count?: number | undefined
|
|
194898
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
194899
|
+
is_smoking_detected?: boolean | undefined
|
|
194900
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
194901
|
+
named_sensors?:
|
|
194902
|
+
| {
|
|
194903
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
194904
|
+
sensor_name: string
|
|
194905
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
194906
|
+
display_name: string
|
|
194907
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
194908
|
+
temperature_celsius?: number | undefined
|
|
194909
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
194910
|
+
temperature_fahrenheit?: number | undefined
|
|
194911
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
194912
|
+
relative_humidity?: number | undefined
|
|
194913
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
194914
|
+
noise_level_decibels?: number | undefined
|
|
194915
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
194916
|
+
noise_level_nrs?: number | undefined
|
|
194917
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
194918
|
+
co2_ppm?: number | undefined
|
|
194919
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
194920
|
+
co_ppm?: number | undefined
|
|
194921
|
+
/** Air quality index, if the device measures it. */
|
|
194922
|
+
air_quality_index?: number | undefined
|
|
194923
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
194924
|
+
mold_risk_level?: string | undefined
|
|
194925
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
194926
|
+
is_occupied?: boolean | undefined
|
|
194927
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
194928
|
+
occupant_count?: number | undefined
|
|
194929
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
194930
|
+
is_smoking_detected?: boolean | undefined
|
|
194931
|
+
}[]
|
|
194932
|
+
| undefined
|
|
194749
194933
|
/** Indicates whether the device supports remote unlocking. */
|
|
194750
194934
|
can_remotely_unlock?: boolean | undefined
|
|
194751
194935
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -206323,6 +206507,8 @@ export type Routes = {
|
|
|
206323
206507
|
allow_instant_key_customization?: boolean | undefined
|
|
206324
206508
|
/** Indicates whether the customer can customize their notification settings, such as the low-battery alert threshold. */
|
|
206325
206509
|
allow_notification_customization?: boolean | undefined
|
|
206510
|
+
/** Indicates whether the customer can move a connected account to a new Seam Bridge when its current bridge is disconnected. */
|
|
206511
|
+
allow_bridge_replacement?: boolean | undefined
|
|
206326
206512
|
}
|
|
206327
206513
|
| undefined
|
|
206328
206514
|
}
|