@oimlsmart/primmel-packages 0.19.0 → 0.21.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/oiml-r129/execution/test-report-skeleton.prl +236 -0
- package/oiml-r144/execution/test-report-skeleton.prl +254 -0
- package/oiml-r60/execution/test-report-skeleton.prl +399 -0
- package/oiml-r91/execution/test-report-skeleton.prl +426 -0
- package/package.json +1 -1
- package/oiml-r129/payload/sample-data.yaml +0 -300
- package/oiml-r144/payload/sample-data.yaml +0 -643
- package/oiml-r60/payload/sample-data.yaml +0 -4900
- package/oiml-r91/payload/sample-data.yaml +0 -464
|
@@ -0,0 +1,426 @@
|
|
|
1
|
+
# OIML R 91 — test report skeleton (kernel 1.14.0's test_report_skeleton,
|
|
2
|
+
# TODO.roadmap/40): the R 91-3:2025 test report format — sections and the
|
|
3
|
+
# form inventory (C140 resolves the entries against the forms register).
|
|
4
|
+
# The R 91-4 type evaluation report is a separate document — its template
|
|
5
|
+
# is the evaluation-report family, not this register.
|
|
6
|
+
test_report_skeleton r91-3/test-report {
|
|
7
|
+
title "OIML R 91-3:2025 — Test report format for speed meters"
|
|
8
|
+
description "The complete test report for an OIML R 91 speed meter evaluation, structured per the R 91-3:2025 report format: the metrological field test, the laboratory programme per R 91-2, and the category-specific tests."
|
|
9
|
+
note "R 91-4 additionally defines the TYPE EVALUATION REPORT format — a separate document from the lab test report (R 91-3); its template is the evaluation-report family, not this register."
|
|
10
|
+
section 01 {
|
|
11
|
+
title "Metrological field test (OIML R 91-2, 4)"
|
|
12
|
+
form r91-3/report-1-1 {
|
|
13
|
+
file "01-01-field-test"
|
|
14
|
+
title "1.1 Traffic condition during measurement (metrological field test)"
|
|
15
|
+
conformance_test /conf/field/stationary-field-test
|
|
16
|
+
requirements { /req/metrological/mpe-stationary /req/metrological/measuring-intervals /req/metrological/indicated-speed /req/category-moving/stationary-mode }
|
|
17
|
+
required always
|
|
18
|
+
}
|
|
19
|
+
form r91-3/report-1-2 {
|
|
20
|
+
file "01-02-statistical-analysis"
|
|
21
|
+
title "1.2 Statistical analysis of errors (optional)"
|
|
22
|
+
conformance_test /conf/field/stationary-field-test
|
|
23
|
+
requirements { /req/metrological/mpe-stationary }
|
|
24
|
+
required conditional
|
|
25
|
+
notes "Optional per R 91-2, 4.7 — the statistical analysis is completed when the field-test error distribution warrants it."
|
|
26
|
+
}
|
|
27
|
+
form r91-3/report-1-3 {
|
|
28
|
+
file "01-03-image-evidence"
|
|
29
|
+
title "1.3 Assignment to image evidence"
|
|
30
|
+
conformance_test /conf/field/stationary-field-test
|
|
31
|
+
requirements { /req/metrological/vehicle-identification }
|
|
32
|
+
required always
|
|
33
|
+
}
|
|
34
|
+
}
|
|
35
|
+
section 02 {
|
|
36
|
+
title "Metrological laboratory tests by traffic simulation (OIML R 91-2, 5)"
|
|
37
|
+
form r91-3/report-2-1 {
|
|
38
|
+
file "02-01-dynamic-performance"
|
|
39
|
+
title "2.1 Dynamic performance test"
|
|
40
|
+
conformance_test /conf/field/dynamic-performance
|
|
41
|
+
requirements { /req/metrological/mpe-stationary /req/metrological/relevant-speed-values }
|
|
42
|
+
required always
|
|
43
|
+
}
|
|
44
|
+
form r91-3/report-2-2 {
|
|
45
|
+
file "02-02-speed-linearity"
|
|
46
|
+
title "2.2 Speed linearity test"
|
|
47
|
+
conformance_test /conf/linearities/speed-linearity
|
|
48
|
+
requirements { /req/metrological/linearity-limit }
|
|
49
|
+
required always
|
|
50
|
+
}
|
|
51
|
+
form r91-3/report-2-3 {
|
|
52
|
+
file "02-03-distance-linearity"
|
|
53
|
+
title "2.3 Distance linearity test"
|
|
54
|
+
conformance_test /conf/linearities/distance-linearity
|
|
55
|
+
requirements { /req/metrological/distance-angle-indication }
|
|
56
|
+
required always
|
|
57
|
+
}
|
|
58
|
+
form r91-3/report-2-4 {
|
|
59
|
+
file "02-04-angle-linearity"
|
|
60
|
+
title "2.4 Angle linearity test"
|
|
61
|
+
conformance_test /conf/linearities/angle-linearity
|
|
62
|
+
requirements { /req/metrological/distance-angle-indication }
|
|
63
|
+
required always
|
|
64
|
+
}
|
|
65
|
+
}
|
|
66
|
+
section 03 {
|
|
67
|
+
title "Influence factor and disturbance tests (OIML R 91-2, 6)"
|
|
68
|
+
form r91-3/report-3-1 {
|
|
69
|
+
file "03-01-dry-heat-operating"
|
|
70
|
+
title "3.1 Dry heat (operating)"
|
|
71
|
+
conformance_test /conf/influence/dry-heat-operating
|
|
72
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
73
|
+
required always
|
|
74
|
+
}
|
|
75
|
+
form r91-3/report-3-2 {
|
|
76
|
+
file "03-02-dry-heat-storage"
|
|
77
|
+
title "3.2 Dry heat (storage)"
|
|
78
|
+
conformance_test /conf/disturbances/dry-heat-storage
|
|
79
|
+
requirements { /req/metrological/disturbances }
|
|
80
|
+
required always
|
|
81
|
+
}
|
|
82
|
+
form r91-3/report-3-3 {
|
|
83
|
+
file "03-03-cold-operating"
|
|
84
|
+
title "3.3 Cold (operating)"
|
|
85
|
+
conformance_test /conf/influence/cold-operating
|
|
86
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
87
|
+
required always
|
|
88
|
+
}
|
|
89
|
+
form r91-3/report-3-4 {
|
|
90
|
+
file "03-04-cold-storage"
|
|
91
|
+
title "3.4 Cold (storage)"
|
|
92
|
+
conformance_test /conf/disturbances/cold-storage
|
|
93
|
+
requirements { /req/metrological/disturbances }
|
|
94
|
+
required always
|
|
95
|
+
}
|
|
96
|
+
form r91-3/report-3-5 {
|
|
97
|
+
file "03-05-damp-heat-cyclic"
|
|
98
|
+
title "3.5 Damp heat, cyclic (condensing)"
|
|
99
|
+
conformance_test /conf/influence/damp-heat-cyclic
|
|
100
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
101
|
+
required always
|
|
102
|
+
}
|
|
103
|
+
form r91-3/report-3-6 {
|
|
104
|
+
file "03-06-water"
|
|
105
|
+
title "3.6 Water (optional)"
|
|
106
|
+
conformance_test /conf/disturbances/water
|
|
107
|
+
requirements { /req/metrological/disturbances }
|
|
108
|
+
required conditional
|
|
109
|
+
notes "Optional test (R 91-2, 6.1 Tables 1-2) — applied when relevant for the declared point of use and installation conditions."
|
|
110
|
+
}
|
|
111
|
+
form r91-3/report-3-7 {
|
|
112
|
+
file "03-07-sand-and-dust"
|
|
113
|
+
title "3.7 Sand and dust (optional)"
|
|
114
|
+
conformance_test /conf/disturbances/sand-and-dust
|
|
115
|
+
requirements { /req/metrological/disturbances }
|
|
116
|
+
required conditional
|
|
117
|
+
notes "Optional test (R 91-2, 6.1 Tables 1-2) — applied when relevant for the declared point of use and installation conditions."
|
|
118
|
+
}
|
|
119
|
+
form r91-3/report-3-8 {
|
|
120
|
+
file "03-08-salt-mist"
|
|
121
|
+
title "3.8 Salt mist (optional)"
|
|
122
|
+
conformance_test /conf/disturbances/salt-mist
|
|
123
|
+
requirements { /req/metrological/disturbances }
|
|
124
|
+
required conditional
|
|
125
|
+
notes "Optional test (R 91-2, 6.1 Table 1, row 6) — applied when relevant for the declared point of use and installation conditions."
|
|
126
|
+
}
|
|
127
|
+
form r91-3/report-3-9 {
|
|
128
|
+
file "03-09-vibration-random"
|
|
129
|
+
title "3.9 Vibration (random)"
|
|
130
|
+
conformance_test /conf/influence/vibration-random
|
|
131
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
132
|
+
required always
|
|
133
|
+
}
|
|
134
|
+
form r91-3/report-3-10 {
|
|
135
|
+
file "03-10-mechanical-shock"
|
|
136
|
+
title "3.10 Mechanical shock"
|
|
137
|
+
conformance_test /conf/disturbances/mechanical-shock
|
|
138
|
+
requirements { /req/metrological/disturbances }
|
|
139
|
+
required always
|
|
140
|
+
}
|
|
141
|
+
form r91-3/report-3-11 {
|
|
142
|
+
file "03-11-dc-mains-voltage-variation"
|
|
143
|
+
title "3.11 DC mains voltage variation"
|
|
144
|
+
conformance_test /conf/influence/dc-mains-voltage-variation
|
|
145
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
146
|
+
required always
|
|
147
|
+
}
|
|
148
|
+
form r91-3/report-3-12 {
|
|
149
|
+
file "03-12-ripple-on-dc-mains"
|
|
150
|
+
title "3.12 Ripple on DC mains power"
|
|
151
|
+
conformance_test /conf/disturbances/ripple-on-dc-mains
|
|
152
|
+
requirements { /req/metrological/disturbances }
|
|
153
|
+
required always
|
|
154
|
+
}
|
|
155
|
+
form r91-3/report-3-13 {
|
|
156
|
+
file "03-13-ac-mains-voltage-variation"
|
|
157
|
+
title "3.13 AC mains voltage variation"
|
|
158
|
+
conformance_test /conf/influence/ac-mains-voltage-variation
|
|
159
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
160
|
+
required always
|
|
161
|
+
}
|
|
162
|
+
form r91-3/report-3-14 {
|
|
163
|
+
file "03-14-ac-mains-frequency-variation"
|
|
164
|
+
title "3.14 AC mains frequency variation"
|
|
165
|
+
conformance_test /conf/influence/ac-mains-frequency-variation
|
|
166
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
167
|
+
required always
|
|
168
|
+
}
|
|
169
|
+
form r91-3/report-3-15 {
|
|
170
|
+
file "03-15-dc-mains-voltage-dips"
|
|
171
|
+
title "3.15 DC mains voltage dips, short interruptions and (short term) voltage variations"
|
|
172
|
+
conformance_test /conf/disturbances/dc-mains-voltage-dips
|
|
173
|
+
requirements { /req/metrological/disturbances }
|
|
174
|
+
required always
|
|
175
|
+
}
|
|
176
|
+
form r91-3/report-3-16 {
|
|
177
|
+
file "03-16-ac-mains-voltage-dips"
|
|
178
|
+
title "3.16 AC mains voltage dips, short interruptions and reductions"
|
|
179
|
+
conformance_test /conf/disturbances/ac-mains-voltage-dips
|
|
180
|
+
requirements { /req/metrological/disturbances }
|
|
181
|
+
required always
|
|
182
|
+
}
|
|
183
|
+
form r91-3/report-3-17 {
|
|
184
|
+
file "03-17-ac-mains-frequency-harmonics"
|
|
185
|
+
title "3.17 AC mains frequency harmonics"
|
|
186
|
+
conformance_test /conf/disturbances/ac-mains-frequency-harmonics
|
|
187
|
+
requirements { /req/metrological/disturbances }
|
|
188
|
+
required always
|
|
189
|
+
}
|
|
190
|
+
form r91-3/report-3-18 {
|
|
191
|
+
file "03-18-vlf-lf-disturbances"
|
|
192
|
+
title "3.18 VLF and LF disturbances on AC and DC mains"
|
|
193
|
+
conformance_test /conf/disturbances/vlf-lf-disturbances-ac-mains
|
|
194
|
+
requirements { /req/metrological/disturbances }
|
|
195
|
+
required always
|
|
196
|
+
}
|
|
197
|
+
form r91-3/report-3-19 {
|
|
198
|
+
file "03-19-bursts-ac-dc-mains"
|
|
199
|
+
title "3.19 Bursts (transients) on AC and DC mains"
|
|
200
|
+
conformance_test /conf/disturbances/bursts-ac-dc-mains
|
|
201
|
+
requirements { /req/metrological/disturbances }
|
|
202
|
+
required always
|
|
203
|
+
}
|
|
204
|
+
form r91-3/report-3-20 {
|
|
205
|
+
file "03-20-surges-ac-dc-mains"
|
|
206
|
+
title "3.20 Surges on AC and DC mains power lines"
|
|
207
|
+
conformance_test /conf/disturbances/surges-ac-dc-mains
|
|
208
|
+
requirements { /req/metrological/disturbances }
|
|
209
|
+
required always
|
|
210
|
+
}
|
|
211
|
+
form r91-3/report-3-21 {
|
|
212
|
+
file "03-21-bursts-signal-lines"
|
|
213
|
+
title "3.21 Bursts (transients) on signal, data and control lines"
|
|
214
|
+
conformance_test /conf/disturbances/bursts-signal-lines
|
|
215
|
+
requirements { /req/metrological/disturbances }
|
|
216
|
+
required always
|
|
217
|
+
}
|
|
218
|
+
form r91-3/report-3-22 {
|
|
219
|
+
file "03-22-surges-signal-lines"
|
|
220
|
+
title "3.22 Surges on signal, data and control lines"
|
|
221
|
+
conformance_test /conf/disturbances/surges-signal-lines
|
|
222
|
+
requirements { /req/metrological/disturbances }
|
|
223
|
+
required always
|
|
224
|
+
}
|
|
225
|
+
form r91-3/report-3-23 {
|
|
226
|
+
file "03-23-ac-mains-magnetic-field"
|
|
227
|
+
title "3.23 AC mains power frequency magnetic field"
|
|
228
|
+
conformance_test /conf/disturbances/ac-mains-power-frequency-magnetic-field
|
|
229
|
+
requirements { /req/metrological/disturbances }
|
|
230
|
+
required always
|
|
231
|
+
}
|
|
232
|
+
form r91-3/report-3-24 {
|
|
233
|
+
file "03-24-conducted-rf-common-mode"
|
|
234
|
+
title "3.24 Conducted (common mode) currents generated by RF electromagnetic fields"
|
|
235
|
+
conformance_test /conf/disturbances/conducted-rf-common-mode-currents
|
|
236
|
+
requirements { /req/metrological/disturbances }
|
|
237
|
+
required always
|
|
238
|
+
}
|
|
239
|
+
form r91-3/report-3-25 {
|
|
240
|
+
file "03-25-rf-electromagnetic-fields"
|
|
241
|
+
title "3.25 RF electromagnetic fields"
|
|
242
|
+
conformance_test /conf/disturbances/rf-electromagnetic-fields
|
|
243
|
+
requirements { /req/metrological/disturbances }
|
|
244
|
+
required always
|
|
245
|
+
}
|
|
246
|
+
form r91-3/report-3-26 {
|
|
247
|
+
file "03-26-electrostatic-discharges"
|
|
248
|
+
title "3.26 Electrostatic discharges"
|
|
249
|
+
conformance_test /conf/disturbances/electrostatic-discharges
|
|
250
|
+
requirements { /req/metrological/disturbances }
|
|
251
|
+
required always
|
|
252
|
+
}
|
|
253
|
+
form r91-3/report-3-27 {
|
|
254
|
+
file "03-27-internal-battery-low-voltage"
|
|
255
|
+
title "3.27 Low voltage of internal battery"
|
|
256
|
+
conformance_test /conf/influence/internal-battery-low-voltage
|
|
257
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
258
|
+
required always
|
|
259
|
+
}
|
|
260
|
+
form r91-3/report-3-28 {
|
|
261
|
+
file "03-28-road-vehicle-battery"
|
|
262
|
+
title "3.28 Voltage variations of a road vehicle battery"
|
|
263
|
+
conformance_test /conf/influence/road-vehicle-battery-voltage-variations
|
|
264
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
265
|
+
required always
|
|
266
|
+
}
|
|
267
|
+
form r91-3/report-3-29 {
|
|
268
|
+
file "03-29-transient-supply-lines"
|
|
269
|
+
title "3.29 Electrical transient conduction along supply lines of external 12 V and 24 V batteries"
|
|
270
|
+
conformance_test /conf/disturbances/transient-conduction-supply-lines
|
|
271
|
+
requirements { /req/metrological/disturbances }
|
|
272
|
+
required always
|
|
273
|
+
}
|
|
274
|
+
form r91-3/report-3-30 {
|
|
275
|
+
file "03-30-transient-other-lines"
|
|
276
|
+
title "3.30 Electrical transient conduction via lines other than supply lines for external 12 V and 24 V batteries"
|
|
277
|
+
conformance_test /conf/disturbances/transient-conduction-other-lines
|
|
278
|
+
requirements { /req/metrological/disturbances }
|
|
279
|
+
required always
|
|
280
|
+
}
|
|
281
|
+
form r91-3/report-3-31 {
|
|
282
|
+
file "03-31-battery-cranking"
|
|
283
|
+
title "3.31 Battery voltage variations during cranking"
|
|
284
|
+
conformance_test /conf/disturbances/battery-voltage-cranking
|
|
285
|
+
requirements { /req/metrological/disturbances }
|
|
286
|
+
required always
|
|
287
|
+
}
|
|
288
|
+
form r91-3/report-3-32 {
|
|
289
|
+
file "03-32-load-dump"
|
|
290
|
+
title "3.32 Load dump test"
|
|
291
|
+
conformance_test /conf/disturbances/load-dump
|
|
292
|
+
requirements { /req/metrological/disturbances }
|
|
293
|
+
required always
|
|
294
|
+
}
|
|
295
|
+
form r91-3/report-3-33 {
|
|
296
|
+
file "03-33-acceleration"
|
|
297
|
+
title "3.33 Acceleration test"
|
|
298
|
+
conformance_test /conf/field/acceleration-test
|
|
299
|
+
requirements { /req/metrological/mpe-stationary }
|
|
300
|
+
required always
|
|
301
|
+
}
|
|
302
|
+
form r91-3/report-3-34 {
|
|
303
|
+
file "03-34-further-influence"
|
|
304
|
+
title "3.34 Further influence quantity tests"
|
|
305
|
+
requirements { /req/metrological/linearity-limit }
|
|
306
|
+
required always
|
|
307
|
+
}
|
|
308
|
+
form r91-3/report-3-35 {
|
|
309
|
+
file "03-35-installation-alignment"
|
|
310
|
+
title "3.35 Installation and alignment of sensor and camera"
|
|
311
|
+
conformance_test /conf/linearities/alignment-misalignment
|
|
312
|
+
requirements { /req/category-across-road/alignment-error }
|
|
313
|
+
required always
|
|
314
|
+
}
|
|
315
|
+
}
|
|
316
|
+
section 04 {
|
|
317
|
+
title "Tests specific to certain categories of speed meters (OIML R 91-2, 7)"
|
|
318
|
+
form r91-3/report-4-1 {
|
|
319
|
+
file "04-01-doppler-radar"
|
|
320
|
+
title "4.1 Doppler-radar based speed meters"
|
|
321
|
+
requirements { /req/category-doppler-radar/beam-width /req/category-doppler-radar/frequency-spectrum /req/category-doppler-radar/spectrum-stability /req/category-doppler-radar/side-lobe }
|
|
322
|
+
required always
|
|
323
|
+
}
|
|
324
|
+
form r91-3/report-4-2 {
|
|
325
|
+
file "04-02-range-finding"
|
|
326
|
+
title "4.2 Range-finding based speed meters"
|
|
327
|
+
requirements { /req/category-range-finding/beam-width /req/category-range-finding/max-distance-viewfinder /req/category-range-finding/pulse-stability /req/category-range-finding/wavelength }
|
|
328
|
+
required always
|
|
329
|
+
}
|
|
330
|
+
form r91-3/report-4-3 {
|
|
331
|
+
file "04-03-average-speed"
|
|
332
|
+
title "4.3 Average speed meters"
|
|
333
|
+
requirements { /req/category-average-speed/detection-field-size /req/category-average-speed/time-synchronisation /req/category-average-speed/image-time-evidence }
|
|
334
|
+
required always
|
|
335
|
+
}
|
|
336
|
+
form r91-3/report-4-4 {
|
|
337
|
+
file "04-04-fixed-distance"
|
|
338
|
+
title "4.4 Fixed-distance speed meters"
|
|
339
|
+
requirements { /req/category-fixed-distance/detection-point-distance /req/category-fixed-distance/redundancy }
|
|
340
|
+
required always
|
|
341
|
+
}
|
|
342
|
+
form r91-3/report-4-5 {
|
|
343
|
+
file "04-05-image-based"
|
|
344
|
+
title "4.5 Image based speed meters"
|
|
345
|
+
conformance_test /conf/category-image-based/image-quality
|
|
346
|
+
requirements { /req/category-image-based/image-quality /req/category-image-based/position-marking /req/category-image-based/position-distances }
|
|
347
|
+
required always
|
|
348
|
+
}
|
|
349
|
+
form r91-3/report-4-6 {
|
|
350
|
+
file "04-06-across-road"
|
|
351
|
+
title "4.6 Across-the-road speed meters"
|
|
352
|
+
conformance_test /conf/examinations/across-road-examination
|
|
353
|
+
requirements { /req/category-across-road/reference-marking /req/category-across-road/cosine-verification }
|
|
354
|
+
required always
|
|
355
|
+
}
|
|
356
|
+
}
|
|
357
|
+
section 05 {
|
|
358
|
+
title "Moving speed meters (OIML R 91-2, 7.7)"
|
|
359
|
+
form r91-3/report-5-1 {
|
|
360
|
+
file "05-01-moving-field-test"
|
|
361
|
+
title "5.1 Moving metrological field test"
|
|
362
|
+
conformance_test /conf/field/moving-field-test
|
|
363
|
+
requirements { /req/category-moving/mpe-moving }
|
|
364
|
+
required always
|
|
365
|
+
}
|
|
366
|
+
form r91-3/report-5-2 {
|
|
367
|
+
file "05-02-ego-field-test"
|
|
368
|
+
title "5.2 Metrological field test of the ego speed meter"
|
|
369
|
+
conformance_test /conf/field/ego-field-test
|
|
370
|
+
requirements { /req/category-moving/ego-speed /req/category-moving/ego-adjustment }
|
|
371
|
+
required always
|
|
372
|
+
}
|
|
373
|
+
form r91-3/report-5-3 {
|
|
374
|
+
file "05-03-moving-traffic-simulation"
|
|
375
|
+
title "5.3 Traffic simulation for moving speed meters"
|
|
376
|
+
requirements { /req/category-moving/mpe-moving /req/category-moving/ego-speed }
|
|
377
|
+
required always
|
|
378
|
+
}
|
|
379
|
+
}
|
|
380
|
+
section 06 {
|
|
381
|
+
title "Software (OIML R 91-2, 8.3)"
|
|
382
|
+
form r91-3/report-6-1 {
|
|
383
|
+
file "06-01-software-general"
|
|
384
|
+
title "6.1 General requirements [mandatory]"
|
|
385
|
+
conformance_test /conf/software/software-examination
|
|
386
|
+
requirements { /req/technical/software }
|
|
387
|
+
required always
|
|
388
|
+
}
|
|
389
|
+
form r91-3/report-6-2 {
|
|
390
|
+
file "06-02-software-protection"
|
|
391
|
+
title "6.2 Software protection [mandatory]"
|
|
392
|
+
conformance_test /conf/software/software-examination
|
|
393
|
+
requirements { /req/technical/software }
|
|
394
|
+
required always
|
|
395
|
+
}
|
|
396
|
+
form r91-3/report-6-3 {
|
|
397
|
+
file "06-03-software-hardware-support"
|
|
398
|
+
title "6.3 Support of hardware features [mandatory]"
|
|
399
|
+
conformance_test /conf/software/software-examination
|
|
400
|
+
requirements { /req/technical/software }
|
|
401
|
+
required always
|
|
402
|
+
}
|
|
403
|
+
form r91-3/report-6-4 {
|
|
404
|
+
file "06-04-software-separation"
|
|
405
|
+
title "6.4 Specification and separation of legally relevant parts and specification of interfaces [optional]"
|
|
406
|
+
conformance_test /conf/software/software-examination
|
|
407
|
+
requirements { /req/technical/software }
|
|
408
|
+
required always
|
|
409
|
+
}
|
|
410
|
+
form r91-3/report-6-5 {
|
|
411
|
+
file "06-05-software-maintenance"
|
|
412
|
+
title "6.5 Maintenance and re-configuration [optional]"
|
|
413
|
+
conformance_test /conf/software/software-examination
|
|
414
|
+
requirements { /req/technical/software }
|
|
415
|
+
required always
|
|
416
|
+
}
|
|
417
|
+
}
|
|
418
|
+
section 07 {
|
|
419
|
+
title "General remarks"
|
|
420
|
+
form r91-3/report-general-remarks {
|
|
421
|
+
file "07-general-remarks"
|
|
422
|
+
title "General remarks"
|
|
423
|
+
required always
|
|
424
|
+
}
|
|
425
|
+
}
|
|
426
|
+
}
|
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@oimlsmart/primmel-packages",
|
|
3
|
-
"version": "0.
|
|
3
|
+
"version": "0.21.0",
|
|
4
4
|
"description": "The OIML SMART platform's authoritative model content: every Recommendation, the OIML-CS scheme, the CASCO foundations, the shared modules, and the product/program reference packages as Primmel (.prl) packages — the single source of truth the platform's data trees regenerate from. Consumed by the smart monorepo (oimlsmart/smart) at a pinned version (TODO.repos/02).",
|
|