@enyo-energy/sunspec-sdk 0.0.103 → 0.0.105
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/index.d.cts +1 -0
- package/dist/cjs/sunspec-battery-schedule-handler.cjs +76 -28
- package/dist/cjs/sunspec-battery-schedule-handler.d.cts +33 -6
- package/dist/cjs/sunspec-devices.cjs +36 -20
- package/dist/cjs/sunspec-devices.d.cts +15 -0
- package/dist/cjs/sunspec-interfaces.cjs +9 -2
- package/dist/cjs/sunspec-interfaces.d.cts +11 -4
- package/dist/cjs/sunspec-modbus-client.cjs +64 -19
- package/dist/cjs/sunspec-modbus-client.d.cts +17 -6
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/index.d.ts +1 -0
- package/dist/sunspec-battery-schedule-handler.d.ts +33 -6
- package/dist/sunspec-battery-schedule-handler.js +76 -28
- package/dist/sunspec-devices.d.ts +15 -0
- package/dist/sunspec-devices.js +35 -20
- package/dist/sunspec-interfaces.d.ts +11 -4
- package/dist/sunspec-interfaces.js +9 -2
- package/dist/sunspec-modbus-client.d.ts +17 -6
- package/dist/sunspec-modbus-client.js +64 -19
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
package/dist/index.d.ts
CHANGED
|
@@ -7,5 +7,6 @@ export { SunspecCalibrationStorage, createSunspecCalibrationStorage } from './su
|
|
|
7
7
|
export { SunspecBatteryCalibrationDriver } from './sunspec-battery-calibration-driver.js';
|
|
8
8
|
export { SunspecBatteryFeatureCalibrator, type SunspecBatteryFeatureCalibratorOptions, decodeFeatureResults, } from './sunspec-battery-feature-calibrator.js';
|
|
9
9
|
export { SunspecBatteryScheduleHandler, type SunspecScheduleRegisters, type SunspecBatteryScheduleHandlerOptions, } from './sunspec-battery-schedule-handler.js';
|
|
10
|
+
export { type EnergyAppModbus, type EnergyAppModbusInstance, type ModbusOptions, } from '@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js';
|
|
10
11
|
export { type EnyoDataBusSetStorageScheduleV1, type EnyoStorageScheduleEntry, EnyoStorageScheduleModeEnum, EnyoStorageScheduleDirectionEnum, } from '@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js';
|
|
11
12
|
export { AbstractCalibrationStorage, InMemoryCalibrationStorage, type AckResult, type CalibrationResult, type CalibrationState, type CalibrationSnapshot, type CalibrationRestoreCallback, type RestoreReason, SnapshotService, type SnapshotServiceOptions, DEFAULT_AUTO_STOP_MS, AbstractBatteryCalibrationDriver, BatteryCalibrator, type BatteryCalibratorOptions, type BatteryCalibratorConfig, DEFAULT_BATTERY_CALIBRATOR_CONFIG, CalibrationResultStore, type CalibrationResultStoreData, CalibrationTrigger, type CalibrationTriggerOptions, } from '@enyo-energy/appliance-calibration';
|
|
@@ -19,9 +19,10 @@ export interface BatteryControlsClient {
|
|
|
19
19
|
*/
|
|
20
20
|
export type BatteryModificationRecorder = Pick<SnapshotService<SunspecBatteryControls>, 'recordModification'>;
|
|
21
21
|
/**
|
|
22
|
-
* Snapshot of the writable Model 124 registers taken at schedule install time
|
|
23
|
-
*
|
|
24
|
-
*
|
|
22
|
+
* Snapshot of the writable Model 124 registers taken at schedule install time.
|
|
23
|
+
* The base library hands it back to `onRollback`, but the release path does not
|
|
24
|
+
* replay it — see `releaseToAuto`. It survives as the record of the installed
|
|
25
|
+
* `wChaMax` and the pre-schedule charge source. JSON-serialisable because
|
|
25
26
|
* `EnergyAppStorage` round-trips it.
|
|
26
27
|
*
|
|
27
28
|
* The snapshotted `wChaMax` doubles as the denominator for the `inWRte` /
|
|
@@ -63,8 +64,9 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
|
|
|
63
64
|
* Sticky pre-schedule snapshot, captured once on the first `onInit` and
|
|
64
65
|
* held across every subsequent schedule-to-schedule replacement. Cleared
|
|
65
66
|
* only when a real rollback fires (`mode: auto` from the data bus or
|
|
66
|
-
* `dispose`).
|
|
67
|
-
*
|
|
67
|
+
* `dispose`). Supplies the `wChaMax` denominator for the percentage math
|
|
68
|
+
* and the charge source to hand back on release — taken from the *original*
|
|
69
|
+
* pre-schedule read rather than the register set the device happens to be
|
|
68
70
|
* in at the moment of replacement.
|
|
69
71
|
*/
|
|
70
72
|
private originalBaseline?;
|
|
@@ -76,6 +78,11 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
|
|
|
76
78
|
* write the snapshot back during a replacement.
|
|
77
79
|
*/
|
|
78
80
|
private suppressNextRollbackWrite;
|
|
81
|
+
/**
|
|
82
|
+
* Mirrors the base class's private `disposed` flag so the auto-release
|
|
83
|
+
* path can tell "released and gone" from "released and still live".
|
|
84
|
+
*/
|
|
85
|
+
private isDisposed;
|
|
79
86
|
constructor(opts: SunspecBatteryScheduleHandlerOptions);
|
|
80
87
|
/**
|
|
81
88
|
* Override the base-class data-bus router so a schedule-to-schedule
|
|
@@ -86,9 +93,29 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
|
|
|
86
93
|
* normally there.
|
|
87
94
|
*/
|
|
88
95
|
applyMessage(msg: EnyoDataBusSetStorageScheduleV1): Promise<void>;
|
|
96
|
+
dispose(): void;
|
|
89
97
|
protected onInit(_active: ActiveStorageScheduleEntry): Promise<SunspecScheduleRegisters>;
|
|
90
98
|
protected onChange(active: ActiveStorageScheduleEntry, _previous: ActiveStorageScheduleEntry | undefined): void;
|
|
91
|
-
protected onRollback(
|
|
99
|
+
protected onRollback(_registers: SunspecScheduleRegisters): void;
|
|
100
|
+
/**
|
|
101
|
+
* Hand the battery back to its own logic: clear StorCtl_Mod and open both
|
|
102
|
+
* rate setpoints back up to 100 %.
|
|
103
|
+
*
|
|
104
|
+
* This deliberately does *not* replay the snapshot captured at `onInit`.
|
|
105
|
+
* That snapshot is whatever the registers happened to hold when the
|
|
106
|
+
* schedule started — and if a previous schedule had already stranded a
|
|
107
|
+
* limit there, restoring it re-latches the limit and the battery can never
|
|
108
|
+
* climb out. The only correct end state for "we are no longer controlling
|
|
109
|
+
* this battery" is the one written here, and it is the same set of
|
|
110
|
+
* registers a schedule entry touches, so nothing else is left dangling.
|
|
111
|
+
*
|
|
112
|
+
* `wChaMax` is not restored because a schedule never writes it — the
|
|
113
|
+
* percentage math divides against it instead.
|
|
114
|
+
*
|
|
115
|
+
* @param chargeSource - `chaGriSet` to restore; falls back to PV-only,
|
|
116
|
+
* since grid charging is only ever switched on by a Charge entry.
|
|
117
|
+
*/
|
|
118
|
+
private releaseToAuto;
|
|
92
119
|
protected onError(err: Error): void;
|
|
93
120
|
private applyEntry;
|
|
94
121
|
}
|
|
@@ -19,8 +19,9 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
19
19
|
* Sticky pre-schedule snapshot, captured once on the first `onInit` and
|
|
20
20
|
* held across every subsequent schedule-to-schedule replacement. Cleared
|
|
21
21
|
* only when a real rollback fires (`mode: auto` from the data bus or
|
|
22
|
-
* `dispose`).
|
|
23
|
-
*
|
|
22
|
+
* `dispose`). Supplies the `wChaMax` denominator for the percentage math
|
|
23
|
+
* and the charge source to hand back on release — taken from the *original*
|
|
24
|
+
* pre-schedule read rather than the register set the device happens to be
|
|
24
25
|
* in at the moment of replacement.
|
|
25
26
|
*/
|
|
26
27
|
originalBaseline;
|
|
@@ -32,6 +33,11 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
32
33
|
* write the snapshot back during a replacement.
|
|
33
34
|
*/
|
|
34
35
|
suppressNextRollbackWrite = false;
|
|
36
|
+
/**
|
|
37
|
+
* Mirrors the base class's private `disposed` flag so the auto-release
|
|
38
|
+
* path can tell "released and gone" from "released and still live".
|
|
39
|
+
*/
|
|
40
|
+
isDisposed = false;
|
|
35
41
|
constructor(opts) {
|
|
36
42
|
super(opts);
|
|
37
43
|
this.sunspecClient = opts.sunspecClient;
|
|
@@ -49,11 +55,15 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
49
55
|
* normally there.
|
|
50
56
|
*/
|
|
51
57
|
async applyMessage(msg) {
|
|
52
|
-
|
|
58
|
+
const isForThisAppliance = msg.applianceId === this.applianceIdForLog;
|
|
59
|
+
if (isForThisAppliance
|
|
53
60
|
&& msg.data.mode === EnyoStorageScheduleModeEnum.Schedule
|
|
54
61
|
&& this.getActiveEntry() !== undefined) {
|
|
55
62
|
this.suppressNextRollbackWrite = true;
|
|
56
63
|
}
|
|
64
|
+
// Captured before the base class runs: with a schedule active, its
|
|
65
|
+
// `doReleaseSchedule → onRollback` already performs the auto release.
|
|
66
|
+
const hadActiveSchedule = this.getActiveEntry() !== undefined;
|
|
57
67
|
try {
|
|
58
68
|
await super.applyMessage(msg);
|
|
59
69
|
}
|
|
@@ -63,6 +73,30 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
63
73
|
// otherwise stay set and silently swallow the next real rollback.
|
|
64
74
|
this.suppressNextRollbackWrite = false;
|
|
65
75
|
}
|
|
76
|
+
if (isForThisAppliance
|
|
77
|
+
&& msg.data.mode === EnyoStorageScheduleModeEnum.Auto
|
|
78
|
+
&& !hadActiveSchedule
|
|
79
|
+
&& !this.isDisposed) {
|
|
80
|
+
// `mode: auto` with no schedule running is a no-op in the base
|
|
81
|
+
// library (`doReleaseSchedule` returns early when idle), so nothing
|
|
82
|
+
// would reach the device. That is not harmless: Model 124 setpoints
|
|
83
|
+
// latch — an interrupted schedule (modbus drop, package restart)
|
|
84
|
+
// leaves StorCtl_Mod and InWRte set, and with InOutWRte_RvrtTms = 0
|
|
85
|
+
// the inverter never reverts on its own. Seen in production as a
|
|
86
|
+
// battery pinned at ~2 % charge rate for hours while the energy
|
|
87
|
+
// manager sent `auto` every 40 s and got an `Accepted` back.
|
|
88
|
+
//
|
|
89
|
+
// Writing the release unconditionally is safe because it is
|
|
90
|
+
// idempotent: it is exactly the register set that means
|
|
91
|
+
// "no external control".
|
|
92
|
+
await this.releaseToAuto().catch(err => {
|
|
93
|
+
console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: auto release failed: ${err}`);
|
|
94
|
+
});
|
|
95
|
+
}
|
|
96
|
+
}
|
|
97
|
+
dispose() {
|
|
98
|
+
this.isDisposed = true;
|
|
99
|
+
super.dispose();
|
|
66
100
|
}
|
|
67
101
|
async onInit(_active) {
|
|
68
102
|
if (this.originalBaseline !== undefined) {
|
|
@@ -101,7 +135,7 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
101
135
|
console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onChange write failed for entry ${active.indexInSchedule}: ${err}`);
|
|
102
136
|
});
|
|
103
137
|
}
|
|
104
|
-
onRollback(
|
|
138
|
+
onRollback(_registers) {
|
|
105
139
|
if (this.suppressNextRollbackWrite) {
|
|
106
140
|
// Schedule-to-schedule replacement. Do NOT write the snapshot
|
|
107
141
|
// back; the new schedule's first `onChange` will own the
|
|
@@ -119,19 +153,41 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
119
153
|
// that follows — so a concurrent `onInit` queued behind this one
|
|
120
154
|
// (impossible today, but defensive) cannot observe a half-cleared
|
|
121
155
|
// state.
|
|
156
|
+
const chargeSource = this.originalBaseline?.chaGriSet;
|
|
122
157
|
this.originalBaseline = undefined;
|
|
123
158
|
this.installedWChaMax = undefined;
|
|
124
|
-
void (
|
|
125
|
-
|
|
126
|
-
|
|
127
|
-
|
|
128
|
-
|
|
129
|
-
|
|
130
|
-
|
|
131
|
-
|
|
132
|
-
|
|
133
|
-
|
|
134
|
-
|
|
159
|
+
void this.releaseToAuto(chargeSource).catch(err => {
|
|
160
|
+
console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onRollback failed: ${err}`);
|
|
161
|
+
});
|
|
162
|
+
}
|
|
163
|
+
/**
|
|
164
|
+
* Hand the battery back to its own logic: clear StorCtl_Mod and open both
|
|
165
|
+
* rate setpoints back up to 100 %.
|
|
166
|
+
*
|
|
167
|
+
* This deliberately does *not* replay the snapshot captured at `onInit`.
|
|
168
|
+
* That snapshot is whatever the registers happened to hold when the
|
|
169
|
+
* schedule started — and if a previous schedule had already stranded a
|
|
170
|
+
* limit there, restoring it re-latches the limit and the battery can never
|
|
171
|
+
* climb out. The only correct end state for "we are no longer controlling
|
|
172
|
+
* this battery" is the one written here, and it is the same set of
|
|
173
|
+
* registers a schedule entry touches, so nothing else is left dangling.
|
|
174
|
+
*
|
|
175
|
+
* `wChaMax` is not restored because a schedule never writes it — the
|
|
176
|
+
* percentage math divides against it instead.
|
|
177
|
+
*
|
|
178
|
+
* @param chargeSource - `chaGriSet` to restore; falls back to PV-only,
|
|
179
|
+
* since grid charging is only ever switched on by a Charge entry.
|
|
180
|
+
*/
|
|
181
|
+
async releaseToAuto(chargeSource) {
|
|
182
|
+
await this.sunspecClient.writeBatteryControls(this.unitId, {
|
|
183
|
+
storCtlMod: SunspecStorageControlMode.NONE,
|
|
184
|
+
chaGriSet: chargeSource ?? SunspecChargeSource.PV,
|
|
185
|
+
inWRte: 100,
|
|
186
|
+
outWRte: 100,
|
|
187
|
+
});
|
|
188
|
+
await this.getSnapshotService()?.recordModification([
|
|
189
|
+
'storCtlMod', 'chaGriSet', 'inWRte', 'outWRte',
|
|
190
|
+
]);
|
|
135
191
|
}
|
|
136
192
|
onError(err) {
|
|
137
193
|
this.onErrorCallback?.(err);
|
|
@@ -139,19 +195,11 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
139
195
|
async applyEntry(active) {
|
|
140
196
|
const { direction, powerW } = active.entry;
|
|
141
197
|
if (direction === EnyoStorageScheduleDirectionEnum.Idle) {
|
|
142
|
-
// Idle entry: hand the battery back to its own autonomous logic
|
|
143
|
-
//
|
|
144
|
-
//
|
|
145
|
-
//
|
|
146
|
-
|
|
147
|
-
const baselineRegisters = this.originalBaseline;
|
|
148
|
-
if (!baselineRegisters) {
|
|
149
|
-
throw new Error(`no usable baseline for idle entry (originalBaseline=undefined)`);
|
|
150
|
-
}
|
|
151
|
-
await this.sunspecClient.writeBatteryControls(this.unitId, baselineRegisters);
|
|
152
|
-
await this.getSnapshotService()?.recordModification([
|
|
153
|
-
'storCtlMod', 'chaGriSet', 'wChaMax', 'inWRte', 'outWRte',
|
|
154
|
-
]);
|
|
198
|
+
// Idle entry: hand the battery back to its own autonomous logic —
|
|
199
|
+
// the same release the `mode: auto` path performs. The schedule
|
|
200
|
+
// itself keeps running, so a subsequent Charge / Discharge entry
|
|
201
|
+
// can resume external control.
|
|
202
|
+
await this.releaseToAuto(this.originalBaseline?.chaGriSet);
|
|
155
203
|
return;
|
|
156
204
|
}
|
|
157
205
|
const baseline = this.installedWChaMax;
|
|
@@ -510,6 +510,21 @@ export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryF
|
|
|
510
510
|
/**
|
|
511
511
|
* Sunspec Battery implementation
|
|
512
512
|
*/
|
|
513
|
+
/**
|
|
514
|
+
* Derive the storage mode from Model 124's StorCtl_Mod bitfield.
|
|
515
|
+
*
|
|
516
|
+
* The bits mark *which rate setpoint the device is enforcing* — bit 0 for
|
|
517
|
+
* InWRte, bit 1 for OutWRte — not which direction is permitted. So no bit set
|
|
518
|
+
* is the autonomous mode, and both bits set is the most externally controlled
|
|
519
|
+
* state there is, which is the opposite of what the naming suggests. Reading
|
|
520
|
+
* them the other way round meant a battery running its own logic reported
|
|
521
|
+
* `holding`, a fully clamped one reported `auto`, and no appliance could ever
|
|
522
|
+
* report that it had been handed back to itself.
|
|
523
|
+
*
|
|
524
|
+
* @param controls - Model 124 control registers, or null when unreadable.
|
|
525
|
+
* @returns The mode, or null when StorCtl_Mod could not be read.
|
|
526
|
+
*/
|
|
527
|
+
export declare function deriveStorageMode(controls: SunspecBatteryControls | null): SunspecStorageMode | null;
|
|
513
528
|
export declare class SunspecBattery extends BaseSunspecDevice {
|
|
514
529
|
private readonly featureMode;
|
|
515
530
|
private readonly capabilities;
|
package/dist/sunspec-devices.js
CHANGED
|
@@ -1425,6 +1425,37 @@ export function filterFeaturesByCalibrationResult(detected, result, controllable
|
|
|
1425
1425
|
/**
|
|
1426
1426
|
* Sunspec Battery implementation
|
|
1427
1427
|
*/
|
|
1428
|
+
/**
|
|
1429
|
+
* Derive the storage mode from Model 124's StorCtl_Mod bitfield.
|
|
1430
|
+
*
|
|
1431
|
+
* The bits mark *which rate setpoint the device is enforcing* — bit 0 for
|
|
1432
|
+
* InWRte, bit 1 for OutWRte — not which direction is permitted. So no bit set
|
|
1433
|
+
* is the autonomous mode, and both bits set is the most externally controlled
|
|
1434
|
+
* state there is, which is the opposite of what the naming suggests. Reading
|
|
1435
|
+
* them the other way round meant a battery running its own logic reported
|
|
1436
|
+
* `holding`, a fully clamped one reported `auto`, and no appliance could ever
|
|
1437
|
+
* report that it had been handed back to itself.
|
|
1438
|
+
*
|
|
1439
|
+
* @param controls - Model 124 control registers, or null when unreadable.
|
|
1440
|
+
* @returns The mode, or null when StorCtl_Mod could not be read.
|
|
1441
|
+
*/
|
|
1442
|
+
export function deriveStorageMode(controls) {
|
|
1443
|
+
if (!controls || controls.storCtlMod === undefined) {
|
|
1444
|
+
return null;
|
|
1445
|
+
}
|
|
1446
|
+
const chargeLimited = (controls.storCtlMod & 0x0001) !== 0;
|
|
1447
|
+
const dischargeLimited = (controls.storCtlMod & 0x0002) !== 0;
|
|
1448
|
+
if (!chargeLimited && !dischargeLimited) {
|
|
1449
|
+
return SunspecStorageMode.AUTO;
|
|
1450
|
+
}
|
|
1451
|
+
// Both directions clamped to zero — the battery is parked, not idling.
|
|
1452
|
+
if (chargeLimited && dischargeLimited && controls.inWRte === 0 && controls.outWRte === 0) {
|
|
1453
|
+
return SunspecStorageMode.HOLDING;
|
|
1454
|
+
}
|
|
1455
|
+
return dischargeLimited && !chargeLimited
|
|
1456
|
+
? SunspecStorageMode.DISCHARGE
|
|
1457
|
+
: SunspecStorageMode.CHARGE;
|
|
1458
|
+
}
|
|
1428
1459
|
export class SunspecBattery extends BaseSunspecDevice {
|
|
1429
1460
|
featureMode;
|
|
1430
1461
|
capabilities;
|
|
@@ -1579,7 +1610,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1579
1610
|
battery: {
|
|
1580
1611
|
connectedToApplianceId: inverterApplianceId,
|
|
1581
1612
|
storageMode: this.mapToEnyoStorageMode(storageMode),
|
|
1582
|
-
maxChargingPowerW: batteryData
|
|
1613
|
+
maxChargingPowerW: batteryData?.wChaMax,
|
|
1583
1614
|
maxDischargePowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.outWRte !== undefined ? batteryData.wChaMax * batteryData.outWRte : undefined,
|
|
1584
1615
|
activeChargeLimitW: activeChargeLimitW,
|
|
1585
1616
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
@@ -1607,7 +1638,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1607
1638
|
...existingAppliance?.battery,
|
|
1608
1639
|
connectedToApplianceId: inverterApplianceId,
|
|
1609
1640
|
storageMode: this.mapToEnyoStorageMode(storageMode),
|
|
1610
|
-
maxChargingPowerW: batteryData
|
|
1641
|
+
maxChargingPowerW: batteryData?.wChaMax,
|
|
1611
1642
|
maxDischargePowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.outWRte !== undefined ? batteryData.wChaMax * batteryData.outWRte : undefined,
|
|
1612
1643
|
activeChargeLimitW: activeChargeLimitW,
|
|
1613
1644
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
@@ -1766,7 +1797,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1766
1797
|
battery: {
|
|
1767
1798
|
...appliance?.battery,
|
|
1768
1799
|
storageMode: this.mapToEnyoStorageMode(storageMode),
|
|
1769
|
-
maxChargingPowerW: batteryData
|
|
1800
|
+
maxChargingPowerW: batteryData?.wChaMax,
|
|
1770
1801
|
maxDischargePowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.outWRte !== undefined ? batteryData.wChaMax * batteryData.outWRte : undefined,
|
|
1771
1802
|
activeChargeLimitW: this.computeActiveChargeLimitW(batteryData),
|
|
1772
1803
|
activeDischargeLimitW: this.computeActiveDischargeLimitW(batteryData),
|
|
@@ -1970,23 +2001,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1970
2001
|
return (batteryData.wChaMax * batteryData.outWRte) / 100;
|
|
1971
2002
|
}
|
|
1972
2003
|
determineStorageMode(controls) {
|
|
1973
|
-
|
|
1974
|
-
return null;
|
|
1975
|
-
}
|
|
1976
|
-
const chargeEnabled = (controls.storCtlMod & 0x0001) !== 0;
|
|
1977
|
-
const dischargeEnabled = (controls.storCtlMod & 0x0002) !== 0;
|
|
1978
|
-
if (chargeEnabled && dischargeEnabled) {
|
|
1979
|
-
return SunspecStorageMode.AUTO;
|
|
1980
|
-
}
|
|
1981
|
-
else if (chargeEnabled && !dischargeEnabled) {
|
|
1982
|
-
return SunspecStorageMode.CHARGE;
|
|
1983
|
-
}
|
|
1984
|
-
else if (!chargeEnabled && dischargeEnabled) {
|
|
1985
|
-
return SunspecStorageMode.DISCHARGE;
|
|
1986
|
-
}
|
|
1987
|
-
else {
|
|
1988
|
-
return SunspecStorageMode.HOLDING;
|
|
1989
|
-
}
|
|
2004
|
+
return deriveStorageMode(controls);
|
|
1990
2005
|
}
|
|
1991
2006
|
/**
|
|
1992
2007
|
* Check if grid charging is enabled
|
|
@@ -503,7 +503,14 @@ export declare enum SunspecBatteryEvent1 {
|
|
|
503
503
|
* - To ensure external control works properly, the appropriate bits must be set
|
|
504
504
|
*/
|
|
505
505
|
export declare enum SunspecStorageControlMode {
|
|
506
|
-
|
|
506
|
+
/**
|
|
507
|
+
* No bit set — no external setpoint is active and the battery runs its own
|
|
508
|
+
* autonomous logic. This, not `CHARGE | DISCHARGE`, is what "auto" means on
|
|
509
|
+
* Model 124: the bits say *which rate setpoint is being enforced*, so
|
|
510
|
+
* clearing them is what hands control back to the device.
|
|
511
|
+
*/
|
|
512
|
+
NONE = 0,
|
|
513
|
+
CHARGE = 1,// Bit 0 - the InWRte charge-rate setpoint is active
|
|
507
514
|
DISCHARGE = 2
|
|
508
515
|
}
|
|
509
516
|
/**
|
|
@@ -778,9 +785,9 @@ export declare enum SunspecChargeSource {
|
|
|
778
785
|
* Storage modes for simplified battery control
|
|
779
786
|
*/
|
|
780
787
|
export declare enum SunspecStorageMode {
|
|
781
|
-
CHARGE = "charge",//
|
|
782
|
-
DISCHARGE = "discharge",//
|
|
783
|
-
HOLDING = "holding",//
|
|
788
|
+
CHARGE = "charge",// Charging is externally rate-limited via InWRte
|
|
789
|
+
DISCHARGE = "discharge",// Discharging is externally rate-limited via OutWRte
|
|
790
|
+
HOLDING = "holding",// Both directions clamped to 0 % — battery is parked
|
|
784
791
|
AUTO = "auto"
|
|
785
792
|
}
|
|
786
793
|
/**
|
|
@@ -213,8 +213,15 @@ export var SunspecBatteryEvent1;
|
|
|
213
213
|
*/
|
|
214
214
|
export var SunspecStorageControlMode;
|
|
215
215
|
(function (SunspecStorageControlMode) {
|
|
216
|
+
/**
|
|
217
|
+
* No bit set — no external setpoint is active and the battery runs its own
|
|
218
|
+
* autonomous logic. This, not `CHARGE | DISCHARGE`, is what "auto" means on
|
|
219
|
+
* Model 124: the bits say *which rate setpoint is being enforced*, so
|
|
220
|
+
* clearing them is what hands control back to the device.
|
|
221
|
+
*/
|
|
222
|
+
SunspecStorageControlMode[SunspecStorageControlMode["NONE"] = 0] = "NONE";
|
|
216
223
|
SunspecStorageControlMode[SunspecStorageControlMode["CHARGE"] = 1] = "CHARGE";
|
|
217
|
-
SunspecStorageControlMode[SunspecStorageControlMode["DISCHARGE"] = 2] = "DISCHARGE"; // Bit 1 -
|
|
224
|
+
SunspecStorageControlMode[SunspecStorageControlMode["DISCHARGE"] = 2] = "DISCHARGE"; // Bit 1 - the OutWRte discharge-rate setpoint is active
|
|
218
225
|
// Note: Higher bits may control other modes like autonomous/self-consumption
|
|
219
226
|
// but these are device-specific and not standardized in SunSpec
|
|
220
227
|
})(SunspecStorageControlMode || (SunspecStorageControlMode = {}));
|
|
@@ -259,7 +266,7 @@ export var SunspecStorageMode;
|
|
|
259
266
|
SunspecStorageMode["CHARGE"] = "charge";
|
|
260
267
|
SunspecStorageMode["DISCHARGE"] = "discharge";
|
|
261
268
|
SunspecStorageMode["HOLDING"] = "holding";
|
|
262
|
-
SunspecStorageMode["AUTO"] = "auto"; //
|
|
269
|
+
SunspecStorageMode["AUTO"] = "auto"; // No external setpoint active (StorCtl_Mod = 0)
|
|
263
270
|
})(SunspecStorageMode || (SunspecStorageMode = {}));
|
|
264
271
|
/**
|
|
265
272
|
* Battery control structure for writing to Model 124
|
|
@@ -18,7 +18,7 @@
|
|
|
18
18
|
*/
|
|
19
19
|
import { type SunspecInverterControls, type SunspecInverterData, type SunspecInverterSettings, type SunspecMeterData, type SunspecModel, type SunspecMPPTData, type SunspecBatteryData, type SunspecBatteryBaseData, type SunspecBatteryControls, SunspecStorageMode, type IModbusPacingConfig, type IModbusResilienceConfig } from "./sunspec-interfaces.js";
|
|
20
20
|
import { EnergyAppModbusDataType, IConnectionHealth } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/interfaces.js";
|
|
21
|
-
import { EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
|
|
21
|
+
import { EnergyAppModbus, EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
|
|
22
22
|
import { EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
23
23
|
/**
|
|
24
24
|
* Thrown when a single Modbus transaction (read/write/connect/disconnect) exceeds its configured
|
|
@@ -34,11 +34,15 @@ export declare class ModbusOperationTimeoutError extends Error {
|
|
|
34
34
|
* Get (or create) the singleton SunspecModbusClient for this network device.
|
|
35
35
|
* Increments the refcount; pair with `releaseSunspecClient` on teardown.
|
|
36
36
|
*
|
|
37
|
-
* NOTE: `pacing` and `
|
|
38
|
-
* host:port. Because the client is cached and refcounted, a later caller
|
|
39
|
-
* receives the already-created instance and its config is ignored.
|
|
37
|
+
* NOTE: `pacing`, `resilience` and `modbusFactory` are only applied when the client is FIRST
|
|
38
|
+
* created for a given host:port. Because the client is cached and refcounted, a later caller
|
|
39
|
+
* passing different config receives the already-created instance and its config is ignored.
|
|
40
|
+
*
|
|
41
|
+
* `modbusFactory` lets a caller supply their own Modbus backend (the factory whose `connect()`
|
|
42
|
+
* opens a per-unit connection) instead of the one from `energyApp.useModbus()` — e.g. a mock for
|
|
43
|
+
* tests, or an alternative transport. When provided, `energyApp` may be passed as `undefined`.
|
|
40
44
|
*/
|
|
41
|
-
export declare function getOrCreateSunspecClient(energyApp: EnergyApp, host: string, port?: number, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig): SunspecModbusClient;
|
|
45
|
+
export declare function getOrCreateSunspecClient(energyApp: EnergyApp | undefined, host: string, port?: number, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus): SunspecModbusClient;
|
|
42
46
|
/**
|
|
43
47
|
* Release a refcount on the network-device client. When the last consumer releases,
|
|
44
48
|
* the client is fully disconnected (all units closed) and removed from the registry.
|
|
@@ -63,6 +67,7 @@ export declare function retryAsync<T>(fn: (attempt: number) => Promise<T>, opts:
|
|
|
63
67
|
export declare class SunspecModbusClient {
|
|
64
68
|
private energyApp;
|
|
65
69
|
private pacing;
|
|
70
|
+
private modbusFactory?;
|
|
66
71
|
private modbusInstances;
|
|
67
72
|
private faultTolerantReaders;
|
|
68
73
|
private discoveredModelsByUnit;
|
|
@@ -79,7 +84,13 @@ export declare class SunspecModbusClient {
|
|
|
79
84
|
private resilience;
|
|
80
85
|
private poisonedUnits;
|
|
81
86
|
private lastOkAtByUnit;
|
|
82
|
-
constructor(energyApp: EnergyApp, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig);
|
|
87
|
+
constructor(energyApp: EnergyApp | undefined, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
|
|
88
|
+
/**
|
|
89
|
+
* The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
|
|
90
|
+
* if one was given, otherwise the host application's default (`energyApp.useModbus()`). The
|
|
91
|
+
* constructor guarantees at least one of the two is present.
|
|
92
|
+
*/
|
|
93
|
+
private useModbus;
|
|
83
94
|
/**
|
|
84
95
|
* Connect to a Modbus device unit. Multiple unit IDs on the same network device share this
|
|
85
96
|
* client; calling connect() with different unit IDs adds each as a separately-managed unit.
|
|
@@ -46,15 +46,19 @@ const registryKey = (host, port) => `${host}:${port}`;
|
|
|
46
46
|
* Get (or create) the singleton SunspecModbusClient for this network device.
|
|
47
47
|
* Increments the refcount; pair with `releaseSunspecClient` on teardown.
|
|
48
48
|
*
|
|
49
|
-
* NOTE: `pacing` and `
|
|
50
|
-
* host:port. Because the client is cached and refcounted, a later caller
|
|
51
|
-
* receives the already-created instance and its config is ignored.
|
|
49
|
+
* NOTE: `pacing`, `resilience` and `modbusFactory` are only applied when the client is FIRST
|
|
50
|
+
* created for a given host:port. Because the client is cached and refcounted, a later caller
|
|
51
|
+
* passing different config receives the already-created instance and its config is ignored.
|
|
52
|
+
*
|
|
53
|
+
* `modbusFactory` lets a caller supply their own Modbus backend (the factory whose `connect()`
|
|
54
|
+
* opens a per-unit connection) instead of the one from `energyApp.useModbus()` — e.g. a mock for
|
|
55
|
+
* tests, or an alternative transport. When provided, `energyApp` may be passed as `undefined`.
|
|
52
56
|
*/
|
|
53
|
-
export function getOrCreateSunspecClient(energyApp, host, port = 502, pacing, resilience) {
|
|
57
|
+
export function getOrCreateSunspecClient(energyApp, host, port = 502, pacing, resilience, modbusFactory) {
|
|
54
58
|
const key = registryKey(host, port);
|
|
55
59
|
let entry = CLIENT_REGISTRY.get(key);
|
|
56
60
|
if (!entry) {
|
|
57
|
-
entry = { client: new SunspecModbusClient(energyApp, pacing, resilience), refcount: 0 };
|
|
61
|
+
entry = { client: new SunspecModbusClient(energyApp, pacing, resilience, modbusFactory), refcount: 0 };
|
|
58
62
|
CLIENT_REGISTRY.set(key, entry);
|
|
59
63
|
}
|
|
60
64
|
entry.refcount++;
|
|
@@ -120,6 +124,7 @@ export async function retryAsync(fn, opts) {
|
|
|
120
124
|
export class SunspecModbusClient {
|
|
121
125
|
energyApp;
|
|
122
126
|
pacing;
|
|
127
|
+
modbusFactory;
|
|
123
128
|
// Per-unit Modbus instance/reader/discovered-models maps. One client = one network device,
|
|
124
129
|
// many unit IDs share that client (each unit ID is one EnergyAppModbusInstance underneath).
|
|
125
130
|
modbusInstances = new Map();
|
|
@@ -163,20 +168,47 @@ export class SunspecModbusClient {
|
|
|
163
168
|
// the transport still reports connected but that has gone quiet past staleSocketMs is presumed
|
|
164
169
|
// dead. Absent entry = no successful op yet (never treated as stale — give it a chance).
|
|
165
170
|
lastOkAtByUnit = new Map();
|
|
166
|
-
constructor(
|
|
171
|
+
constructor(
|
|
172
|
+
// The host application. Only used to obtain the default Modbus backend via
|
|
173
|
+
// `energyApp.useModbus()`. May be omitted (`undefined`) when a `modbusFactory` is supplied.
|
|
174
|
+
energyApp,
|
|
167
175
|
// Opt-in pacing (default off). Passed straight through to `useModbus().connect()`, which
|
|
168
176
|
// serializes frames (`noParallelRequests`) and spaces them (`waitBetweenMessagesMs`) on the
|
|
169
177
|
// connection. An empty object leaves both undefined so the SDK applies its own defaults.
|
|
170
178
|
pacing = {},
|
|
171
179
|
// Per-operation timeouts + half-open detection. Merged with DEFAULT_MODBUS_RESILIENCE_CONFIG
|
|
172
180
|
// so omitted fields keep their defaults.
|
|
173
|
-
resilience = {}
|
|
181
|
+
resilience = {},
|
|
182
|
+
// Optional custom Modbus backend. When provided, its `connect()` is used to open every
|
|
183
|
+
// per-unit connection instead of `energyApp.useModbus()` — letting callers plug in their own
|
|
184
|
+
// Modbus implementation (a mock for tests, or an alternative transport). All the resilience
|
|
185
|
+
// machinery (per-unit connect/reconnect, TLS, pacing, timeouts) is driven through this
|
|
186
|
+
// factory, which is why an already-connected instance would not do: the client re-opens
|
|
187
|
+
// connections on its own schedule and needs a factory to call.
|
|
188
|
+
modbusFactory) {
|
|
174
189
|
this.energyApp = energyApp;
|
|
175
190
|
this.pacing = pacing;
|
|
191
|
+
this.modbusFactory = modbusFactory;
|
|
192
|
+
if (!energyApp && !modbusFactory) {
|
|
193
|
+
throw new Error("SunspecModbusClient requires either an EnergyApp or a modbusFactory");
|
|
194
|
+
}
|
|
176
195
|
this.connectionHealth = new EnergyAppModbusConnectionHealth();
|
|
177
196
|
this.modbusDataTypeConverter = new EnergyAppModbusDataTypeConverter();
|
|
178
197
|
this.resilience = { ...DEFAULT_MODBUS_RESILIENCE_CONFIG, ...resilience };
|
|
179
198
|
}
|
|
199
|
+
/**
|
|
200
|
+
* The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
|
|
201
|
+
* if one was given, otherwise the host application's default (`energyApp.useModbus()`). The
|
|
202
|
+
* constructor guarantees at least one of the two is present.
|
|
203
|
+
*/
|
|
204
|
+
useModbus() {
|
|
205
|
+
if (this.modbusFactory)
|
|
206
|
+
return this.modbusFactory;
|
|
207
|
+
if (!this.energyApp) {
|
|
208
|
+
throw new Error("SunspecModbusClient has no Modbus backend: neither energyApp nor modbusFactory is set");
|
|
209
|
+
}
|
|
210
|
+
return this.energyApp.useModbus();
|
|
211
|
+
}
|
|
180
212
|
/**
|
|
181
213
|
* Connect to a Modbus device unit. Multiple unit IDs on the same network device share this
|
|
182
214
|
* client; calling connect() with different unit IDs adds each as a separately-managed unit.
|
|
@@ -467,7 +499,7 @@ export class SunspecModbusClient {
|
|
|
467
499
|
// Enforce the connect budget ourselves in addition to forwarding it as the transport's
|
|
468
500
|
// `timeout`: the transport applies it to the TCP handshake, but a sleeping/half-open peer
|
|
469
501
|
// can still leave the returned promise pending — bound it independently.
|
|
470
|
-
candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => this.
|
|
502
|
+
candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => this.useModbus().connect({
|
|
471
503
|
host: hosts,
|
|
472
504
|
port,
|
|
473
505
|
unitId,
|
|
@@ -2238,30 +2270,43 @@ export class SunspecModbusClient {
|
|
|
2238
2270
|
* Set battery storage mode (simplified interface)
|
|
2239
2271
|
*/
|
|
2240
2272
|
async setStorageMode(unitId, mode) {
|
|
2241
|
-
|
|
2273
|
+
// StorCtl_Mod says *which rate setpoint is enforced*, not what the
|
|
2274
|
+
// battery is allowed to do — so releasing control means clearing the
|
|
2275
|
+
// bits, and the rate registers have to be written alongside them.
|
|
2276
|
+
// Setting the bits without touching InWRte/OutWRte would enforce
|
|
2277
|
+
// whatever percentage was left behind by an earlier command.
|
|
2278
|
+
let controls;
|
|
2242
2279
|
switch (mode) {
|
|
2243
2280
|
case SunspecStorageMode.CHARGE:
|
|
2244
|
-
//
|
|
2245
|
-
|
|
2281
|
+
// Enforce the charge-rate setpoint only (bit 0 = 1, bit 1 = 0).
|
|
2282
|
+
controls = { storCtlMod: SunspecStorageControlMode.CHARGE };
|
|
2246
2283
|
break;
|
|
2247
2284
|
case SunspecStorageMode.DISCHARGE:
|
|
2248
|
-
//
|
|
2249
|
-
|
|
2285
|
+
// Enforce the discharge-rate setpoint only (bit 0 = 0, bit 1 = 1).
|
|
2286
|
+
controls = { storCtlMod: SunspecStorageControlMode.DISCHARGE };
|
|
2250
2287
|
break;
|
|
2251
2288
|
case SunspecStorageMode.HOLDING:
|
|
2252
|
-
//
|
|
2253
|
-
|
|
2289
|
+
// Park the battery: both setpoints enforced, both clamped to 0 %.
|
|
2290
|
+
controls = {
|
|
2291
|
+
storCtlMod: SunspecStorageControlMode.CHARGE | SunspecStorageControlMode.DISCHARGE,
|
|
2292
|
+
inWRte: 0,
|
|
2293
|
+
outWRte: 0,
|
|
2294
|
+
};
|
|
2254
2295
|
break;
|
|
2255
2296
|
case SunspecStorageMode.AUTO:
|
|
2256
|
-
//
|
|
2257
|
-
|
|
2297
|
+
// Hand control back: no setpoint enforced, both rates wide open.
|
|
2298
|
+
controls = {
|
|
2299
|
+
storCtlMod: SunspecStorageControlMode.NONE,
|
|
2300
|
+
inWRte: 100,
|
|
2301
|
+
outWRte: 100,
|
|
2302
|
+
};
|
|
2258
2303
|
break;
|
|
2259
2304
|
default:
|
|
2260
2305
|
console.error(`Invalid storage mode: ${mode}`);
|
|
2261
2306
|
return false;
|
|
2262
2307
|
}
|
|
2263
|
-
console.log(`Setting storage mode to ${mode} (
|
|
2264
|
-
return this.writeBatteryControls(unitId,
|
|
2308
|
+
console.log(`Setting storage mode to ${mode} (${JSON.stringify(controls)})`);
|
|
2309
|
+
return this.writeBatteryControls(unitId, controls);
|
|
2265
2310
|
}
|
|
2266
2311
|
/**
|
|
2267
2312
|
* Enable or disable grid charging
|
package/dist/version.d.ts
CHANGED
package/dist/version.js
CHANGED
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@enyo-energy/sunspec-sdk",
|
|
3
|
-
"version": "0.0.
|
|
3
|
+
"version": "0.0.105",
|
|
4
4
|
"description": "enyo Energy Sunspec SDK",
|
|
5
5
|
"type": "module",
|
|
6
6
|
"main": "dist/index.js",
|
|
@@ -41,7 +41,7 @@
|
|
|
41
41
|
},
|
|
42
42
|
"dependencies": {
|
|
43
43
|
"@enyo-energy/appliance-calibration": "0.0.3",
|
|
44
|
-
"@enyo-energy/energy-app-sdk": "^0.0.
|
|
44
|
+
"@enyo-energy/energy-app-sdk": "^0.0.188"
|
|
45
45
|
},
|
|
46
46
|
"volta": {
|
|
47
47
|
"node": "22.17.0"
|