@enyo-energy/sunspec-sdk 0.0.103 → 0.0.105

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -7,5 +7,6 @@ export { SunspecCalibrationStorage, createSunspecCalibrationStorage } from './su
7
7
  export { SunspecBatteryCalibrationDriver } from './sunspec-battery-calibration-driver.cjs';
8
8
  export { SunspecBatteryFeatureCalibrator, type SunspecBatteryFeatureCalibratorOptions, decodeFeatureResults, } from './sunspec-battery-feature-calibrator.cjs';
9
9
  export { SunspecBatteryScheduleHandler, type SunspecScheduleRegisters, type SunspecBatteryScheduleHandlerOptions, } from './sunspec-battery-schedule-handler.cjs';
10
+ export { type EnergyAppModbus, type EnergyAppModbusInstance, type ModbusOptions, } from '@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js';
10
11
  export { type EnyoDataBusSetStorageScheduleV1, type EnyoStorageScheduleEntry, EnyoStorageScheduleModeEnum, EnyoStorageScheduleDirectionEnum, } from '@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js';
11
12
  export { AbstractCalibrationStorage, InMemoryCalibrationStorage, type AckResult, type CalibrationResult, type CalibrationState, type CalibrationSnapshot, type CalibrationRestoreCallback, type RestoreReason, SnapshotService, type SnapshotServiceOptions, DEFAULT_AUTO_STOP_MS, AbstractBatteryCalibrationDriver, BatteryCalibrator, type BatteryCalibratorOptions, type BatteryCalibratorConfig, DEFAULT_BATTERY_CALIBRATOR_CONFIG, CalibrationResultStore, type CalibrationResultStoreData, CalibrationTrigger, type CalibrationTriggerOptions, } from '@enyo-energy/appliance-calibration';
@@ -22,8 +22,9 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
22
22
  * Sticky pre-schedule snapshot, captured once on the first `onInit` and
23
23
  * held across every subsequent schedule-to-schedule replacement. Cleared
24
24
  * only when a real rollback fires (`mode: auto` from the data bus or
25
- * `dispose`). Lets the eventual restore write the *true* baseline rather
26
- * than the last-active-entry register set that the device happens to be
25
+ * `dispose`). Supplies the `wChaMax` denominator for the percentage math
26
+ * and the charge source to hand back on release — taken from the *original*
27
+ * pre-schedule read rather than the register set the device happens to be
27
28
  * in at the moment of replacement.
28
29
  */
29
30
  originalBaseline;
@@ -35,6 +36,11 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
35
36
  * write the snapshot back during a replacement.
36
37
  */
37
38
  suppressNextRollbackWrite = false;
39
+ /**
40
+ * Mirrors the base class's private `disposed` flag so the auto-release
41
+ * path can tell "released and gone" from "released and still live".
42
+ */
43
+ isDisposed = false;
38
44
  constructor(opts) {
39
45
  super(opts);
40
46
  this.sunspecClient = opts.sunspecClient;
@@ -52,11 +58,15 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
52
58
  * normally there.
53
59
  */
54
60
  async applyMessage(msg) {
55
- if (msg.applianceId === this.applianceIdForLog
61
+ const isForThisAppliance = msg.applianceId === this.applianceIdForLog;
62
+ if (isForThisAppliance
56
63
  && msg.data.mode === enyo_data_bus_value_js_1.EnyoStorageScheduleModeEnum.Schedule
57
64
  && this.getActiveEntry() !== undefined) {
58
65
  this.suppressNextRollbackWrite = true;
59
66
  }
67
+ // Captured before the base class runs: with a schedule active, its
68
+ // `doReleaseSchedule → onRollback` already performs the auto release.
69
+ const hadActiveSchedule = this.getActiveEntry() !== undefined;
60
70
  try {
61
71
  await super.applyMessage(msg);
62
72
  }
@@ -66,6 +76,30 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
66
76
  // otherwise stay set and silently swallow the next real rollback.
67
77
  this.suppressNextRollbackWrite = false;
68
78
  }
79
+ if (isForThisAppliance
80
+ && msg.data.mode === enyo_data_bus_value_js_1.EnyoStorageScheduleModeEnum.Auto
81
+ && !hadActiveSchedule
82
+ && !this.isDisposed) {
83
+ // `mode: auto` with no schedule running is a no-op in the base
84
+ // library (`doReleaseSchedule` returns early when idle), so nothing
85
+ // would reach the device. That is not harmless: Model 124 setpoints
86
+ // latch — an interrupted schedule (modbus drop, package restart)
87
+ // leaves StorCtl_Mod and InWRte set, and with InOutWRte_RvrtTms = 0
88
+ // the inverter never reverts on its own. Seen in production as a
89
+ // battery pinned at ~2 % charge rate for hours while the energy
90
+ // manager sent `auto` every 40 s and got an `Accepted` back.
91
+ //
92
+ // Writing the release unconditionally is safe because it is
93
+ // idempotent: it is exactly the register set that means
94
+ // "no external control".
95
+ await this.releaseToAuto().catch(err => {
96
+ console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: auto release failed: ${err}`);
97
+ });
98
+ }
99
+ }
100
+ dispose() {
101
+ this.isDisposed = true;
102
+ super.dispose();
69
103
  }
70
104
  async onInit(_active) {
71
105
  if (this.originalBaseline !== undefined) {
@@ -104,7 +138,7 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
104
138
  console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onChange write failed for entry ${active.indexInSchedule}: ${err}`);
105
139
  });
106
140
  }
107
- onRollback(registers) {
141
+ onRollback(_registers) {
108
142
  if (this.suppressNextRollbackWrite) {
109
143
  // Schedule-to-schedule replacement. Do NOT write the snapshot
110
144
  // back; the new schedule's first `onChange` will own the
@@ -122,19 +156,41 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
122
156
  // that follows — so a concurrent `onInit` queued behind this one
123
157
  // (impossible today, but defensive) cannot observe a half-cleared
124
158
  // state.
159
+ const chargeSource = this.originalBaseline?.chaGriSet;
125
160
  this.originalBaseline = undefined;
126
161
  this.installedWChaMax = undefined;
127
- void (async () => {
128
- try {
129
- await this.sunspecClient.writeBatteryControls(this.unitId, registers);
130
- await this.getSnapshotService()?.recordModification([
131
- 'storCtlMod', 'chaGriSet', 'wChaMax', 'inWRte', 'outWRte',
132
- ]);
133
- }
134
- catch (err) {
135
- console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onRollback failed: ${err}`);
136
- }
137
- })();
162
+ void this.releaseToAuto(chargeSource).catch(err => {
163
+ console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onRollback failed: ${err}`);
164
+ });
165
+ }
166
+ /**
167
+ * Hand the battery back to its own logic: clear StorCtl_Mod and open both
168
+ * rate setpoints back up to 100 %.
169
+ *
170
+ * This deliberately does *not* replay the snapshot captured at `onInit`.
171
+ * That snapshot is whatever the registers happened to hold when the
172
+ * schedule started — and if a previous schedule had already stranded a
173
+ * limit there, restoring it re-latches the limit and the battery can never
174
+ * climb out. The only correct end state for "we are no longer controlling
175
+ * this battery" is the one written here, and it is the same set of
176
+ * registers a schedule entry touches, so nothing else is left dangling.
177
+ *
178
+ * `wChaMax` is not restored because a schedule never writes it — the
179
+ * percentage math divides against it instead.
180
+ *
181
+ * @param chargeSource - `chaGriSet` to restore; falls back to PV-only,
182
+ * since grid charging is only ever switched on by a Charge entry.
183
+ */
184
+ async releaseToAuto(chargeSource) {
185
+ await this.sunspecClient.writeBatteryControls(this.unitId, {
186
+ storCtlMod: sunspec_interfaces_js_1.SunspecStorageControlMode.NONE,
187
+ chaGriSet: chargeSource ?? sunspec_interfaces_js_1.SunspecChargeSource.PV,
188
+ inWRte: 100,
189
+ outWRte: 100,
190
+ });
191
+ await this.getSnapshotService()?.recordModification([
192
+ 'storCtlMod', 'chaGriSet', 'inWRte', 'outWRte',
193
+ ]);
138
194
  }
139
195
  onError(err) {
140
196
  this.onErrorCallback?.(err);
@@ -142,19 +198,11 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
142
198
  async applyEntry(active) {
143
199
  const { direction, powerW } = active.entry;
144
200
  if (direction === enyo_data_bus_value_js_1.EnyoStorageScheduleDirectionEnum.Idle) {
145
- // Idle entry: hand the battery back to its own autonomous logic
146
- // by restoring the snapshotted pre-schedule registers (same write
147
- // set as the `mode: auto` rollback path). The schedule itself
148
- // keeps running, so a subsequent Charge / Discharge entry can
149
- // resume external control.
150
- const baselineRegisters = this.originalBaseline;
151
- if (!baselineRegisters) {
152
- throw new Error(`no usable baseline for idle entry (originalBaseline=undefined)`);
153
- }
154
- await this.sunspecClient.writeBatteryControls(this.unitId, baselineRegisters);
155
- await this.getSnapshotService()?.recordModification([
156
- 'storCtlMod', 'chaGriSet', 'wChaMax', 'inWRte', 'outWRte',
157
- ]);
201
+ // Idle entry: hand the battery back to its own autonomous logic —
202
+ // the same release the `mode: auto` path performs. The schedule
203
+ // itself keeps running, so a subsequent Charge / Discharge entry
204
+ // can resume external control.
205
+ await this.releaseToAuto(this.originalBaseline?.chaGriSet);
158
206
  return;
159
207
  }
160
208
  const baseline = this.installedWChaMax;
@@ -19,9 +19,10 @@ export interface BatteryControlsClient {
19
19
  */
20
20
  export type BatteryModificationRecorder = Pick<SnapshotService<SunspecBatteryControls>, 'recordModification'>;
21
21
  /**
22
- * Snapshot of the writable Model 124 registers taken at schedule install time
23
- * and handed back to `onRollback` when the schedule completes, is replaced, or
24
- * is restored after a process restart. JSON-serialisable because
22
+ * Snapshot of the writable Model 124 registers taken at schedule install time.
23
+ * The base library hands it back to `onRollback`, but the release path does not
24
+ * replay it — see `releaseToAuto`. It survives as the record of the installed
25
+ * `wChaMax` and the pre-schedule charge source. JSON-serialisable because
25
26
  * `EnergyAppStorage` round-trips it.
26
27
  *
27
28
  * The snapshotted `wChaMax` doubles as the denominator for the `inWRte` /
@@ -63,8 +64,9 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
63
64
  * Sticky pre-schedule snapshot, captured once on the first `onInit` and
64
65
  * held across every subsequent schedule-to-schedule replacement. Cleared
65
66
  * only when a real rollback fires (`mode: auto` from the data bus or
66
- * `dispose`). Lets the eventual restore write the *true* baseline rather
67
- * than the last-active-entry register set that the device happens to be
67
+ * `dispose`). Supplies the `wChaMax` denominator for the percentage math
68
+ * and the charge source to hand back on release — taken from the *original*
69
+ * pre-schedule read rather than the register set the device happens to be
68
70
  * in at the moment of replacement.
69
71
  */
70
72
  private originalBaseline?;
@@ -76,6 +78,11 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
76
78
  * write the snapshot back during a replacement.
77
79
  */
78
80
  private suppressNextRollbackWrite;
81
+ /**
82
+ * Mirrors the base class's private `disposed` flag so the auto-release
83
+ * path can tell "released and gone" from "released and still live".
84
+ */
85
+ private isDisposed;
79
86
  constructor(opts: SunspecBatteryScheduleHandlerOptions);
80
87
  /**
81
88
  * Override the base-class data-bus router so a schedule-to-schedule
@@ -86,9 +93,29 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
86
93
  * normally there.
87
94
  */
88
95
  applyMessage(msg: EnyoDataBusSetStorageScheduleV1): Promise<void>;
96
+ dispose(): void;
89
97
  protected onInit(_active: ActiveStorageScheduleEntry): Promise<SunspecScheduleRegisters>;
90
98
  protected onChange(active: ActiveStorageScheduleEntry, _previous: ActiveStorageScheduleEntry | undefined): void;
91
- protected onRollback(registers: SunspecScheduleRegisters): void;
99
+ protected onRollback(_registers: SunspecScheduleRegisters): void;
100
+ /**
101
+ * Hand the battery back to its own logic: clear StorCtl_Mod and open both
102
+ * rate setpoints back up to 100 %.
103
+ *
104
+ * This deliberately does *not* replay the snapshot captured at `onInit`.
105
+ * That snapshot is whatever the registers happened to hold when the
106
+ * schedule started — and if a previous schedule had already stranded a
107
+ * limit there, restoring it re-latches the limit and the battery can never
108
+ * climb out. The only correct end state for "we are no longer controlling
109
+ * this battery" is the one written here, and it is the same set of
110
+ * registers a schedule entry touches, so nothing else is left dangling.
111
+ *
112
+ * `wChaMax` is not restored because a schedule never writes it — the
113
+ * percentage math divides against it instead.
114
+ *
115
+ * @param chargeSource - `chaGriSet` to restore; falls back to PV-only,
116
+ * since grid charging is only ever switched on by a Charge entry.
117
+ */
118
+ private releaseToAuto;
92
119
  protected onError(err: Error): void;
93
120
  private applyEntry;
94
121
  }
@@ -5,6 +5,7 @@ exports.detectFeaturesFromRegisters = detectFeaturesFromRegisters;
5
5
  exports.sumMpptBatteryPowerW = sumMpptBatteryPowerW;
6
6
  exports.selectLiveBatteryPowerW = selectLiveBatteryPowerW;
7
7
  exports.filterFeaturesByCalibrationResult = filterFeaturesByCalibrationResult;
8
+ exports.deriveStorageMode = deriveStorageMode;
8
9
  const sunspec_interfaces_js_1 = require("./sunspec-interfaces.cjs");
9
10
  const node_crypto_1 = require("node:crypto");
10
11
  const enyo_appliance_js_1 = require("@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js");
@@ -1434,6 +1435,37 @@ function filterFeaturesByCalibrationResult(detected, result, controllable) {
1434
1435
  /**
1435
1436
  * Sunspec Battery implementation
1436
1437
  */
1438
+ /**
1439
+ * Derive the storage mode from Model 124's StorCtl_Mod bitfield.
1440
+ *
1441
+ * The bits mark *which rate setpoint the device is enforcing* — bit 0 for
1442
+ * InWRte, bit 1 for OutWRte — not which direction is permitted. So no bit set
1443
+ * is the autonomous mode, and both bits set is the most externally controlled
1444
+ * state there is, which is the opposite of what the naming suggests. Reading
1445
+ * them the other way round meant a battery running its own logic reported
1446
+ * `holding`, a fully clamped one reported `auto`, and no appliance could ever
1447
+ * report that it had been handed back to itself.
1448
+ *
1449
+ * @param controls - Model 124 control registers, or null when unreadable.
1450
+ * @returns The mode, or null when StorCtl_Mod could not be read.
1451
+ */
1452
+ function deriveStorageMode(controls) {
1453
+ if (!controls || controls.storCtlMod === undefined) {
1454
+ return null;
1455
+ }
1456
+ const chargeLimited = (controls.storCtlMod & 0x0001) !== 0;
1457
+ const dischargeLimited = (controls.storCtlMod & 0x0002) !== 0;
1458
+ if (!chargeLimited && !dischargeLimited) {
1459
+ return sunspec_interfaces_js_1.SunspecStorageMode.AUTO;
1460
+ }
1461
+ // Both directions clamped to zero — the battery is parked, not idling.
1462
+ if (chargeLimited && dischargeLimited && controls.inWRte === 0 && controls.outWRte === 0) {
1463
+ return sunspec_interfaces_js_1.SunspecStorageMode.HOLDING;
1464
+ }
1465
+ return dischargeLimited && !chargeLimited
1466
+ ? sunspec_interfaces_js_1.SunspecStorageMode.DISCHARGE
1467
+ : sunspec_interfaces_js_1.SunspecStorageMode.CHARGE;
1468
+ }
1437
1469
  class SunspecBattery extends BaseSunspecDevice {
1438
1470
  featureMode;
1439
1471
  capabilities;
@@ -1588,7 +1620,7 @@ class SunspecBattery extends BaseSunspecDevice {
1588
1620
  battery: {
1589
1621
  connectedToApplianceId: inverterApplianceId,
1590
1622
  storageMode: this.mapToEnyoStorageMode(storageMode),
1591
- maxChargingPowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.inWRte !== undefined ? batteryData.wChaMax * batteryData.inWRte : undefined,
1623
+ maxChargingPowerW: batteryData?.wChaMax,
1592
1624
  maxDischargePowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.outWRte !== undefined ? batteryData.wChaMax * batteryData.outWRte : undefined,
1593
1625
  activeChargeLimitW: activeChargeLimitW,
1594
1626
  activeDischargeLimitW: activeDischargeLimitW,
@@ -1616,7 +1648,7 @@ class SunspecBattery extends BaseSunspecDevice {
1616
1648
  ...existingAppliance?.battery,
1617
1649
  connectedToApplianceId: inverterApplianceId,
1618
1650
  storageMode: this.mapToEnyoStorageMode(storageMode),
1619
- maxChargingPowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.inWRte !== undefined ? batteryData.wChaMax * batteryData.inWRte : undefined,
1651
+ maxChargingPowerW: batteryData?.wChaMax,
1620
1652
  maxDischargePowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.outWRte !== undefined ? batteryData.wChaMax * batteryData.outWRte : undefined,
1621
1653
  activeChargeLimitW: activeChargeLimitW,
1622
1654
  activeDischargeLimitW: activeDischargeLimitW,
@@ -1775,7 +1807,7 @@ class SunspecBattery extends BaseSunspecDevice {
1775
1807
  battery: {
1776
1808
  ...appliance?.battery,
1777
1809
  storageMode: this.mapToEnyoStorageMode(storageMode),
1778
- maxChargingPowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.inWRte !== undefined ? batteryData.wChaMax * batteryData.inWRte : undefined,
1810
+ maxChargingPowerW: batteryData?.wChaMax,
1779
1811
  maxDischargePowerW: batteryData && batteryData.wChaMax !== undefined && batteryData.outWRte !== undefined ? batteryData.wChaMax * batteryData.outWRte : undefined,
1780
1812
  activeChargeLimitW: this.computeActiveChargeLimitW(batteryData),
1781
1813
  activeDischargeLimitW: this.computeActiveDischargeLimitW(batteryData),
@@ -1979,23 +2011,7 @@ class SunspecBattery extends BaseSunspecDevice {
1979
2011
  return (batteryData.wChaMax * batteryData.outWRte) / 100;
1980
2012
  }
1981
2013
  determineStorageMode(controls) {
1982
- if (!controls || controls.storCtlMod === undefined) {
1983
- return null;
1984
- }
1985
- const chargeEnabled = (controls.storCtlMod & 0x0001) !== 0;
1986
- const dischargeEnabled = (controls.storCtlMod & 0x0002) !== 0;
1987
- if (chargeEnabled && dischargeEnabled) {
1988
- return sunspec_interfaces_js_1.SunspecStorageMode.AUTO;
1989
- }
1990
- else if (chargeEnabled && !dischargeEnabled) {
1991
- return sunspec_interfaces_js_1.SunspecStorageMode.CHARGE;
1992
- }
1993
- else if (!chargeEnabled && dischargeEnabled) {
1994
- return sunspec_interfaces_js_1.SunspecStorageMode.DISCHARGE;
1995
- }
1996
- else {
1997
- return sunspec_interfaces_js_1.SunspecStorageMode.HOLDING;
1998
- }
2014
+ return deriveStorageMode(controls);
1999
2015
  }
2000
2016
  /**
2001
2017
  * Check if grid charging is enabled
@@ -510,6 +510,21 @@ export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryF
510
510
  /**
511
511
  * Sunspec Battery implementation
512
512
  */
513
+ /**
514
+ * Derive the storage mode from Model 124's StorCtl_Mod bitfield.
515
+ *
516
+ * The bits mark *which rate setpoint the device is enforcing* — bit 0 for
517
+ * InWRte, bit 1 for OutWRte — not which direction is permitted. So no bit set
518
+ * is the autonomous mode, and both bits set is the most externally controlled
519
+ * state there is, which is the opposite of what the naming suggests. Reading
520
+ * them the other way round meant a battery running its own logic reported
521
+ * `holding`, a fully clamped one reported `auto`, and no appliance could ever
522
+ * report that it had been handed back to itself.
523
+ *
524
+ * @param controls - Model 124 control registers, or null when unreadable.
525
+ * @returns The mode, or null when StorCtl_Mod could not be read.
526
+ */
527
+ export declare function deriveStorageMode(controls: SunspecBatteryControls | null): SunspecStorageMode | null;
513
528
  export declare class SunspecBattery extends BaseSunspecDevice {
514
529
  private readonly featureMode;
515
530
  private readonly capabilities;
@@ -216,8 +216,15 @@ var SunspecBatteryEvent1;
216
216
  */
217
217
  var SunspecStorageControlMode;
218
218
  (function (SunspecStorageControlMode) {
219
+ /**
220
+ * No bit set — no external setpoint is active and the battery runs its own
221
+ * autonomous logic. This, not `CHARGE | DISCHARGE`, is what "auto" means on
222
+ * Model 124: the bits say *which rate setpoint is being enforced*, so
223
+ * clearing them is what hands control back to the device.
224
+ */
225
+ SunspecStorageControlMode[SunspecStorageControlMode["NONE"] = 0] = "NONE";
219
226
  SunspecStorageControlMode[SunspecStorageControlMode["CHARGE"] = 1] = "CHARGE";
220
- SunspecStorageControlMode[SunspecStorageControlMode["DISCHARGE"] = 2] = "DISCHARGE"; // Bit 1 - Enable discharge mode (allow external discharge control)
227
+ SunspecStorageControlMode[SunspecStorageControlMode["DISCHARGE"] = 2] = "DISCHARGE"; // Bit 1 - the OutWRte discharge-rate setpoint is active
221
228
  // Note: Higher bits may control other modes like autonomous/self-consumption
222
229
  // but these are device-specific and not standardized in SunSpec
223
230
  })(SunspecStorageControlMode || (exports.SunspecStorageControlMode = SunspecStorageControlMode = {}));
@@ -262,7 +269,7 @@ var SunspecStorageMode;
262
269
  SunspecStorageMode["CHARGE"] = "charge";
263
270
  SunspecStorageMode["DISCHARGE"] = "discharge";
264
271
  SunspecStorageMode["HOLDING"] = "holding";
265
- SunspecStorageMode["AUTO"] = "auto"; // Both charge and discharge allowed
272
+ SunspecStorageMode["AUTO"] = "auto"; // No external setpoint active (StorCtl_Mod = 0)
266
273
  })(SunspecStorageMode || (exports.SunspecStorageMode = SunspecStorageMode = {}));
267
274
  /**
268
275
  * Battery control structure for writing to Model 124
@@ -503,7 +503,14 @@ export declare enum SunspecBatteryEvent1 {
503
503
  * - To ensure external control works properly, the appropriate bits must be set
504
504
  */
505
505
  export declare enum SunspecStorageControlMode {
506
- CHARGE = 1,// Bit 0 - Enable charge mode (allow external charge control)
506
+ /**
507
+ * No bit set — no external setpoint is active and the battery runs its own
508
+ * autonomous logic. This, not `CHARGE | DISCHARGE`, is what "auto" means on
509
+ * Model 124: the bits say *which rate setpoint is being enforced*, so
510
+ * clearing them is what hands control back to the device.
511
+ */
512
+ NONE = 0,
513
+ CHARGE = 1,// Bit 0 - the InWRte charge-rate setpoint is active
507
514
  DISCHARGE = 2
508
515
  }
509
516
  /**
@@ -778,9 +785,9 @@ export declare enum SunspecChargeSource {
778
785
  * Storage modes for simplified battery control
779
786
  */
780
787
  export declare enum SunspecStorageMode {
781
- CHARGE = "charge",// Allow charging only
782
- DISCHARGE = "discharge",// Allow discharging only
783
- HOLDING = "holding",// No charge or discharge (holding mode)
788
+ CHARGE = "charge",// Charging is externally rate-limited via InWRte
789
+ DISCHARGE = "discharge",// Discharging is externally rate-limited via OutWRte
790
+ HOLDING = "holding",// Both directions clamped to 0 % — battery is parked
784
791
  AUTO = "auto"
785
792
  }
786
793
  /**
@@ -53,15 +53,19 @@ const registryKey = (host, port) => `${host}:${port}`;
53
53
  * Get (or create) the singleton SunspecModbusClient for this network device.
54
54
  * Increments the refcount; pair with `releaseSunspecClient` on teardown.
55
55
  *
56
- * NOTE: `pacing` and `resilience` are only applied when the client is FIRST created for a given
57
- * host:port. Because the client is cached and refcounted, a later caller passing different config
58
- * receives the already-created instance and its config is ignored.
56
+ * NOTE: `pacing`, `resilience` and `modbusFactory` are only applied when the client is FIRST
57
+ * created for a given host:port. Because the client is cached and refcounted, a later caller
58
+ * passing different config receives the already-created instance and its config is ignored.
59
+ *
60
+ * `modbusFactory` lets a caller supply their own Modbus backend (the factory whose `connect()`
61
+ * opens a per-unit connection) instead of the one from `energyApp.useModbus()` — e.g. a mock for
62
+ * tests, or an alternative transport. When provided, `energyApp` may be passed as `undefined`.
59
63
  */
60
- function getOrCreateSunspecClient(energyApp, host, port = 502, pacing, resilience) {
64
+ function getOrCreateSunspecClient(energyApp, host, port = 502, pacing, resilience, modbusFactory) {
61
65
  const key = registryKey(host, port);
62
66
  let entry = CLIENT_REGISTRY.get(key);
63
67
  if (!entry) {
64
- entry = { client: new SunspecModbusClient(energyApp, pacing, resilience), refcount: 0 };
68
+ entry = { client: new SunspecModbusClient(energyApp, pacing, resilience, modbusFactory), refcount: 0 };
65
69
  CLIENT_REGISTRY.set(key, entry);
66
70
  }
67
71
  entry.refcount++;
@@ -127,6 +131,7 @@ async function retryAsync(fn, opts) {
127
131
  class SunspecModbusClient {
128
132
  energyApp;
129
133
  pacing;
134
+ modbusFactory;
130
135
  // Per-unit Modbus instance/reader/discovered-models maps. One client = one network device,
131
136
  // many unit IDs share that client (each unit ID is one EnergyAppModbusInstance underneath).
132
137
  modbusInstances = new Map();
@@ -170,20 +175,47 @@ class SunspecModbusClient {
170
175
  // the transport still reports connected but that has gone quiet past staleSocketMs is presumed
171
176
  // dead. Absent entry = no successful op yet (never treated as stale — give it a chance).
172
177
  lastOkAtByUnit = new Map();
173
- constructor(energyApp,
178
+ constructor(
179
+ // The host application. Only used to obtain the default Modbus backend via
180
+ // `energyApp.useModbus()`. May be omitted (`undefined`) when a `modbusFactory` is supplied.
181
+ energyApp,
174
182
  // Opt-in pacing (default off). Passed straight through to `useModbus().connect()`, which
175
183
  // serializes frames (`noParallelRequests`) and spaces them (`waitBetweenMessagesMs`) on the
176
184
  // connection. An empty object leaves both undefined so the SDK applies its own defaults.
177
185
  pacing = {},
178
186
  // Per-operation timeouts + half-open detection. Merged with DEFAULT_MODBUS_RESILIENCE_CONFIG
179
187
  // so omitted fields keep their defaults.
180
- resilience = {}) {
188
+ resilience = {},
189
+ // Optional custom Modbus backend. When provided, its `connect()` is used to open every
190
+ // per-unit connection instead of `energyApp.useModbus()` — letting callers plug in their own
191
+ // Modbus implementation (a mock for tests, or an alternative transport). All the resilience
192
+ // machinery (per-unit connect/reconnect, TLS, pacing, timeouts) is driven through this
193
+ // factory, which is why an already-connected instance would not do: the client re-opens
194
+ // connections on its own schedule and needs a factory to call.
195
+ modbusFactory) {
181
196
  this.energyApp = energyApp;
182
197
  this.pacing = pacing;
198
+ this.modbusFactory = modbusFactory;
199
+ if (!energyApp && !modbusFactory) {
200
+ throw new Error("SunspecModbusClient requires either an EnergyApp or a modbusFactory");
201
+ }
183
202
  this.connectionHealth = new EnergyAppModbusConnectionHealth_js_1.EnergyAppModbusConnectionHealth();
184
203
  this.modbusDataTypeConverter = new EnergyAppModbusDataTypeConverter_js_1.EnergyAppModbusDataTypeConverter();
185
204
  this.resilience = { ...sunspec_interfaces_js_1.DEFAULT_MODBUS_RESILIENCE_CONFIG, ...resilience };
186
205
  }
206
+ /**
207
+ * The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
208
+ * if one was given, otherwise the host application's default (`energyApp.useModbus()`). The
209
+ * constructor guarantees at least one of the two is present.
210
+ */
211
+ useModbus() {
212
+ if (this.modbusFactory)
213
+ return this.modbusFactory;
214
+ if (!this.energyApp) {
215
+ throw new Error("SunspecModbusClient has no Modbus backend: neither energyApp nor modbusFactory is set");
216
+ }
217
+ return this.energyApp.useModbus();
218
+ }
187
219
  /**
188
220
  * Connect to a Modbus device unit. Multiple unit IDs on the same network device share this
189
221
  * client; calling connect() with different unit IDs adds each as a separately-managed unit.
@@ -474,7 +506,7 @@ class SunspecModbusClient {
474
506
  // Enforce the connect budget ourselves in addition to forwarding it as the transport's
475
507
  // `timeout`: the transport applies it to the TCP handshake, but a sleeping/half-open peer
476
508
  // can still leave the returned promise pending — bound it independently.
477
- candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => this.energyApp.useModbus().connect({
509
+ candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => this.useModbus().connect({
478
510
  host: hosts,
479
511
  port,
480
512
  unitId,
@@ -2245,30 +2277,43 @@ class SunspecModbusClient {
2245
2277
  * Set battery storage mode (simplified interface)
2246
2278
  */
2247
2279
  async setStorageMode(unitId, mode) {
2248
- let storCtlMod;
2280
+ // StorCtl_Mod says *which rate setpoint is enforced*, not what the
2281
+ // battery is allowed to do — so releasing control means clearing the
2282
+ // bits, and the rate registers have to be written alongside them.
2283
+ // Setting the bits without touching InWRte/OutWRte would enforce
2284
+ // whatever percentage was left behind by an earlier command.
2285
+ let controls;
2249
2286
  switch (mode) {
2250
2287
  case sunspec_interfaces_js_1.SunspecStorageMode.CHARGE:
2251
- // Enable charge only (bit 0 = 1, bit 1 = 0)
2252
- storCtlMod = sunspec_interfaces_js_1.SunspecStorageControlMode.CHARGE;
2288
+ // Enforce the charge-rate setpoint only (bit 0 = 1, bit 1 = 0).
2289
+ controls = { storCtlMod: sunspec_interfaces_js_1.SunspecStorageControlMode.CHARGE };
2253
2290
  break;
2254
2291
  case sunspec_interfaces_js_1.SunspecStorageMode.DISCHARGE:
2255
- // Enable discharge only (bit 0 = 0, bit 1 = 1)
2256
- storCtlMod = sunspec_interfaces_js_1.SunspecStorageControlMode.DISCHARGE;
2292
+ // Enforce the discharge-rate setpoint only (bit 0 = 0, bit 1 = 1).
2293
+ controls = { storCtlMod: sunspec_interfaces_js_1.SunspecStorageControlMode.DISCHARGE };
2257
2294
  break;
2258
2295
  case sunspec_interfaces_js_1.SunspecStorageMode.HOLDING:
2259
- // Disable both charge and discharge (bits 0 and 1 = 0)
2260
- storCtlMod = 0;
2296
+ // Park the battery: both setpoints enforced, both clamped to 0 %.
2297
+ controls = {
2298
+ storCtlMod: sunspec_interfaces_js_1.SunspecStorageControlMode.CHARGE | sunspec_interfaces_js_1.SunspecStorageControlMode.DISCHARGE,
2299
+ inWRte: 0,
2300
+ outWRte: 0,
2301
+ };
2261
2302
  break;
2262
2303
  case sunspec_interfaces_js_1.SunspecStorageMode.AUTO:
2263
- // Enable both charge and discharge (bits 0 and 1 = 1)
2264
- storCtlMod = sunspec_interfaces_js_1.SunspecStorageControlMode.CHARGE | sunspec_interfaces_js_1.SunspecStorageControlMode.DISCHARGE;
2304
+ // Hand control back: no setpoint enforced, both rates wide open.
2305
+ controls = {
2306
+ storCtlMod: sunspec_interfaces_js_1.SunspecStorageControlMode.NONE,
2307
+ inWRte: 100,
2308
+ outWRte: 100,
2309
+ };
2265
2310
  break;
2266
2311
  default:
2267
2312
  console.error(`Invalid storage mode: ${mode}`);
2268
2313
  return false;
2269
2314
  }
2270
- console.log(`Setting storage mode to ${mode} (control bits: 0x${storCtlMod.toString(16)})`);
2271
- return this.writeBatteryControls(unitId, { storCtlMod });
2315
+ console.log(`Setting storage mode to ${mode} (${JSON.stringify(controls)})`);
2316
+ return this.writeBatteryControls(unitId, controls);
2272
2317
  }
2273
2318
  /**
2274
2319
  * Enable or disable grid charging
@@ -18,7 +18,7 @@
18
18
  */
19
19
  import { type SunspecInverterControls, type SunspecInverterData, type SunspecInverterSettings, type SunspecMeterData, type SunspecModel, type SunspecMPPTData, type SunspecBatteryData, type SunspecBatteryBaseData, type SunspecBatteryControls, SunspecStorageMode, type IModbusPacingConfig, type IModbusResilienceConfig } from "./sunspec-interfaces.cjs";
20
20
  import { EnergyAppModbusDataType, IConnectionHealth } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/interfaces.js";
21
- import { EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
21
+ import { EnergyAppModbus, EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
22
22
  import { EnergyApp } from "@enyo-energy/energy-app-sdk";
23
23
  /**
24
24
  * Thrown when a single Modbus transaction (read/write/connect/disconnect) exceeds its configured
@@ -34,11 +34,15 @@ export declare class ModbusOperationTimeoutError extends Error {
34
34
  * Get (or create) the singleton SunspecModbusClient for this network device.
35
35
  * Increments the refcount; pair with `releaseSunspecClient` on teardown.
36
36
  *
37
- * NOTE: `pacing` and `resilience` are only applied when the client is FIRST created for a given
38
- * host:port. Because the client is cached and refcounted, a later caller passing different config
39
- * receives the already-created instance and its config is ignored.
37
+ * NOTE: `pacing`, `resilience` and `modbusFactory` are only applied when the client is FIRST
38
+ * created for a given host:port. Because the client is cached and refcounted, a later caller
39
+ * passing different config receives the already-created instance and its config is ignored.
40
+ *
41
+ * `modbusFactory` lets a caller supply their own Modbus backend (the factory whose `connect()`
42
+ * opens a per-unit connection) instead of the one from `energyApp.useModbus()` — e.g. a mock for
43
+ * tests, or an alternative transport. When provided, `energyApp` may be passed as `undefined`.
40
44
  */
41
- export declare function getOrCreateSunspecClient(energyApp: EnergyApp, host: string, port?: number, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig): SunspecModbusClient;
45
+ export declare function getOrCreateSunspecClient(energyApp: EnergyApp | undefined, host: string, port?: number, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus): SunspecModbusClient;
42
46
  /**
43
47
  * Release a refcount on the network-device client. When the last consumer releases,
44
48
  * the client is fully disconnected (all units closed) and removed from the registry.
@@ -63,6 +67,7 @@ export declare function retryAsync<T>(fn: (attempt: number) => Promise<T>, opts:
63
67
  export declare class SunspecModbusClient {
64
68
  private energyApp;
65
69
  private pacing;
70
+ private modbusFactory?;
66
71
  private modbusInstances;
67
72
  private faultTolerantReaders;
68
73
  private discoveredModelsByUnit;
@@ -79,7 +84,13 @@ export declare class SunspecModbusClient {
79
84
  private resilience;
80
85
  private poisonedUnits;
81
86
  private lastOkAtByUnit;
82
- constructor(energyApp: EnergyApp, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig);
87
+ constructor(energyApp: EnergyApp | undefined, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
88
+ /**
89
+ * The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
90
+ * if one was given, otherwise the host application's default (`energyApp.useModbus()`). The
91
+ * constructor guarantees at least one of the two is present.
92
+ */
93
+ private useModbus;
83
94
  /**
84
95
  * Connect to a Modbus device unit. Multiple unit IDs on the same network device share this
85
96
  * client; calling connect() with different unit IDs adds each as a separately-managed unit.
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
9
9
  /**
10
10
  * Current version of the enyo Energy App SDK.
11
11
  */
12
- exports.SDK_VERSION = '0.0.103';
12
+ exports.SDK_VERSION = '0.0.105';
13
13
  /**
14
14
  * Gets the current SDK version.
15
15
  * @returns The semantic version string of the SDK
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.103";
8
+ export declare const SDK_VERSION = "0.0.105";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK