@enyo-energy/sunspec-sdk 0.0.101 → 0.0.103

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -3,6 +3,7 @@
3
3
  */
4
4
  import { EnyoBatteryFeature } from "@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js";
5
5
  import { EnyoBatteryStateEnum, EnyoDataBusInverterValuesV1String, EnyoInverterStateEnum } from "@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js";
6
+ import { EnergyAppModbusDataType } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/interfaces.js";
6
7
  /**
7
8
  * A single phase in the tiered retry schedule
8
9
  */
@@ -98,6 +99,86 @@ export interface IModbusResilienceConfig {
98
99
  connectRetryDelayMs?: number;
99
100
  }
100
101
  export declare const DEFAULT_MODBUS_RESILIENCE_CONFIG: Required<IModbusResilienceConfig>;
102
+ /**
103
+ * The appliance role a {@link SunspecCustomDeviceConfig} emulates. Selects the appliance type created
104
+ * on connect and which EnyoDataBus values message {@link SunspecCustomDevice.readData} publishes.
105
+ */
106
+ export type SunspecCustomDeviceRole = 'meter' | 'inverter' | 'battery';
107
+ /**
108
+ * A single pre-defined register a {@link SunspecCustomDevice} reads each poll. Unlike the SunSpec
109
+ * model readers, there is no discovery, scale-factor register, or NOT_IMPLEMENTED sentinel handling:
110
+ * the caller supplies the exact address, type and (optional) fixed scaling for a plain-Modbus device.
111
+ */
112
+ export interface SunspecCustomRegister {
113
+ /**
114
+ * The databus data-field this register populates for the configured role (e.g. `gridPowerW` for a
115
+ * meter, `pvPowerW` for an inverter, `batterySoC` for a battery). Validated against the role's
116
+ * numeric field set at read time; unknown fields are ignored with a warning.
117
+ */
118
+ field: string;
119
+ /** Modbus register address (absolute). */
120
+ address: number;
121
+ /** How to decode the raw registers. */
122
+ dataType: EnergyAppModbusDataType;
123
+ /** Registers to read. Defaults to the natural width of {@link dataType} (1 for 16-bit, 2 for 32-bit). */
124
+ quantity?: number;
125
+ /** Fixed decimal scaling applied as `value * 10^scaleFactor`. Default 0 (no scaling). */
126
+ scaleFactor?: number;
127
+ /** Modbus function code: 3 = holding registers (default), 4 = input registers. */
128
+ functionCode?: 3 | 4;
129
+ }
130
+ /**
131
+ * A writable register exposed through {@link SunspecCustomDevice.writeCustomRegister}. Limited to the
132
+ * data types the client's {@link writeRegisterValue} can serialize (uint16/int16/uint32/int32).
133
+ */
134
+ export interface SunspecCustomWriteRegister {
135
+ /** Caller-facing handle passed to `writeCustomRegister(name, value)`. */
136
+ name: string;
137
+ /** Modbus register address (absolute). */
138
+ address: number;
139
+ /** How to serialize the value. */
140
+ dataType: EnergyAppModbusDataType;
141
+ }
142
+ /**
143
+ * Declarative configuration for a {@link SunspecCustomDevice}: a plain-Modbus device polled through
144
+ * the SDK's resilient connection management but read from a hand-defined static register map rather
145
+ * than a discovered SunSpec model directory.
146
+ */
147
+ export interface SunspecCustomDeviceConfig {
148
+ /** Which appliance role to emulate (drives appliance type + emitted databus message). */
149
+ role: SunspecCustomDeviceRole;
150
+ /** The static registers read every poll and mapped onto the role's databus message. */
151
+ registers: SunspecCustomRegister[];
152
+ /**
153
+ * Maximum registers spanned by a single block read. Registers (grouped per function code) are
154
+ * sorted by address and coalesced — across gaps — into as few reads as possible, each spanning at
155
+ * most this many registers; every register is then sliced out of its block buffer by offset, just
156
+ * like a SunSpec model block. Larger blocks mean fewer round-trips but read any unmapped registers
157
+ * in the gaps (which some devices reject). Default 125 (the Modbus FC03/FC04 per-read limit); a
158
+ * block wider than 125 is still chunked internally.
159
+ */
160
+ blockSize?: number;
161
+ /** Optional writable registers exposed via `writeCustomRegister`. */
162
+ writeRegisters?: SunspecCustomWriteRegister[];
163
+ /**
164
+ * Static operating state to publish for the `inverter` role. Without SunSpec status models there is
165
+ * no register to derive it from, so callers may pin one (e.g. `Mppt`). Ignored for other roles.
166
+ */
167
+ defaultInverterState?: EnyoInverterStateEnum;
168
+ /**
169
+ * Static operating state to publish for the `battery` role. Ignored for other roles.
170
+ */
171
+ defaultBatteryState?: EnyoBatteryStateEnum;
172
+ /**
173
+ * Optional identity written to appliance metadata. There is no SunSpec Common block to read it
174
+ * from, so the caller supplies serial/model/vendor if they want them populated.
175
+ */
176
+ identity?: {
177
+ serialNumber?: string;
178
+ modelName?: string;
179
+ vendorName?: string;
180
+ };
181
+ }
101
182
  /**
102
183
  * Base interface for all SunSpec blocks
103
184
  */
@@ -231,6 +231,10 @@ class SunspecModbusClient {
231
231
  await this._openUnit(host, port, unitId, {
232
232
  connectRetries: 0,
233
233
  connectTimeoutMs: opts.timeoutMs ?? this.resilience.connectTimeoutMs,
234
+ // Fast-fail scan: a mostly-dead RS485 range must cost ~one timeout per unit, so do
235
+ // NOT let the transport also walk a fallback host (which would double the per-unit
236
+ // cost). Warm connects/reconnects still get the in-band fallback.
237
+ useFallbackHosts: false,
234
238
  });
235
239
  console.log(`Probed Sunspec unit ${unitId} at ${host}:${port} — open (opens=${this.openCount}, closes=${this.closeCount}, openUnits=${this.modbusInstances.size})`);
236
240
  });
@@ -402,6 +406,25 @@ class SunspecModbusClient {
402
406
  return false;
403
407
  }
404
408
  }
409
+ /**
410
+ * Build the ordered host list handed to the transport's `host` option for a single connect.
411
+ * The attempt's primary target leads, followed by every OTHER known host (the other of
412
+ * primaryHost/secondaryHost) as an in-band fallback the transport walks in order — so a stale
413
+ * DNS name or a DHCP-changed IP on the first host is tolerated within one connect() instead of
414
+ * only via the client's sequential primary→secondary retry. Deduped; returns a bare string when
415
+ * no distinct fallback exists, leaving single-host devices (and their tests) unaffected.
416
+ */
417
+ buildConnectHosts(primaryTarget) {
418
+ const hosts = [primaryTarget];
419
+ const params = this.connectionParams;
420
+ if (params) {
421
+ for (const h of [params.primaryHost, params.secondaryHost]) {
422
+ if (h && !hosts.includes(h))
423
+ hosts.push(h);
424
+ }
425
+ }
426
+ return hosts.length === 1 ? hosts[0] : hosts;
427
+ }
405
428
  /**
406
429
  * Open a unit, retrying the connect on a transient failure per the resilience config
407
430
  * ({@link IModbusResilienceConfig.connectRetries}). Each attempt is a full {@link _openUnitOnce}
@@ -415,7 +438,11 @@ class SunspecModbusClient {
415
438
  async _openUnit(host, port, unitId, override) {
416
439
  const connectTimeoutMs = override?.connectTimeoutMs ?? this.resilience.connectTimeoutMs;
417
440
  const attempts = (override?.connectRetries ?? this.resilience.connectRetries) + 1;
418
- await retryAsync(() => this._openUnitOnce(host, port, unitId, connectTimeoutMs), {
441
+ // Default ON: a normal connect/reconnect hands the transport BOTH known hosts so a single
442
+ // attempt tolerates DNS/DHCP drift on the first one. probeUnit opts out to stay a fast-fail
443
+ // single-host scan (see probeUnit / _openUnitOnce).
444
+ const useFallbackHosts = override?.useFallbackHosts ?? true;
445
+ await retryAsync(() => this._openUnitOnce(host, port, unitId, connectTimeoutMs, useFallbackHosts), {
419
446
  attempts,
420
447
  delayMs: this.resilience.connectRetryDelayMs,
421
448
  onRetry: (error, attempt) => console.warn(`SunspecModbusClient: connect to ${host}:${port} unit ${unitId} failed ` +
@@ -427,15 +454,28 @@ class SunspecModbusClient {
427
454
  * Open a new Modbus instance for one unit ID and wire up its fault-tolerant reader. Bounds the
428
455
  * connect at `connectTimeoutMs`. On any failure, the just-opened instance (if any) is closed so
429
456
  * we never leak. Caller must hold the connection lock and ensure the unit is not already open.
430
- */
431
- async _openUnitOnce(host, port, unitId, connectTimeoutMs = this.resilience.connectTimeoutMs) {
457
+ *
458
+ * When `useFallbackHosts` is true (the connect/reconnect default), the transport is handed the
459
+ * full host list from {@link buildConnectHosts} — the attempt's primary target plus the other
460
+ * known host — so one connect() tolerates DNS/DHCP drift on the first host in-band, rather than
461
+ * waiting for the client's own sequential primary→secondary retry. The transport walks the list
462
+ * in order, each host bounded by `timeout` (connectTimeoutMs); we scale our own outer budget by
463
+ * the host count so a legitimate multi-host walk isn't aborted mid-fallback. probeUnit passes
464
+ * false to keep speculative RS485 scans a fast-fail single-host probe.
465
+ */
466
+ async _openUnitOnce(host, port, unitId, connectTimeoutMs = this.resilience.connectTimeoutMs, useFallbackHosts = true) {
432
467
  let candidate = null;
468
+ const hosts = useFallbackHosts ? this.buildConnectHosts(host) : host;
469
+ const hostCount = Array.isArray(hosts) ? hosts.length : 1;
470
+ // Each host in the list gets its own `timeout`; bound the whole walk at count × budget so we
471
+ // don't kill a genuine fallback to the second host with the single-host budget.
472
+ const overallBudgetMs = connectTimeoutMs * hostCount;
433
473
  try {
434
474
  // Enforce the connect budget ourselves in addition to forwarding it as the transport's
435
475
  // `timeout`: the transport applies it to the TCP handshake, but a sleeping/half-open peer
436
476
  // can still leave the returned promise pending — bound it independently.
437
- candidate = await this.withTimeout('connect', unitId, connectTimeoutMs, () => this.energyApp.useModbus().connect({
438
- host,
477
+ candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => this.energyApp.useModbus().connect({
478
+ host: hosts,
439
479
  port,
440
480
  unitId,
441
481
  timeout: connectTimeoutMs,
@@ -708,7 +748,16 @@ class SunspecModbusClient {
708
748
  */
709
749
  async detectSunspecBaseAddress(unitId, customBaseAddress) {
710
750
  const instance = this.getInstance(unitId);
711
- // If custom base address provided, try it first (1-based, then 0-based variant)
751
+ // If a custom base address is provided, try it first (0-based, then 1-based variant).
752
+ //
753
+ // A custom base is only a real SunSpec anchor for a device whose map genuinely starts
754
+ // there. It is NOT an anchor when it points at a *model block* inside a shared unit —
755
+ // e.g. a SolarEdge meter block (~40188) co-resident with the inverter on unit 1: the
756
+ // "SunS" marker lives ONLY at the unit's SunSpec root (40000/40001), never at the meter
757
+ // block. So a miss here must NOT fail discovery; fall through to the standard root probe
758
+ // below. (This is exactly the reconnect path that used to strand the meter — its
759
+ // rediscovery threw "not SunSpec compliant" at 40188, returned no models, and poisoned
760
+ // the shared socket, dragging the inverter offline too.)
712
761
  if (customBaseAddress !== undefined) {
713
762
  console.log(`Detect models for custom base address '${customBaseAddress}' ...`);
714
763
  // Try 0-based at custom address
@@ -741,41 +790,44 @@ class SunspecModbusClient {
741
790
  catch (error) {
742
791
  console.debug(`Could not read SunS at ${customBaseAddress + 1}:`, error);
743
792
  }
793
+ console.debug(`No "SunS" marker at custom base ${customBaseAddress}/${customBaseAddress + 1} on unit ${unitId} — ` +
794
+ `falling back to the standard SunSpec root (40001/40000). Expected when the custom base points at a ` +
795
+ `model block inside a shared unit (e.g. a co-resident meter), whose anchor is the unit root.`);
744
796
  }
745
- else {
746
- // Try 1-based addressing first (most common)
747
- try {
748
- const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40001, 2));
749
- if (sunspecId.includes('SunS')) {
750
- console.log('Detected 1-based addressing mode (base address: 40001)');
751
- return {
752
- baseAddress: 40001,
753
- isZeroBased: false,
754
- nextAddress: 40003
755
- };
756
- }
757
- }
758
- catch (error) {
759
- console.debug('Could not read SunS at 40001:', error);
760
- }
761
- // Try 0-based addressing
762
- try {
763
- const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40000, 2));
764
- if (sunspecId.includes('SunS')) {
765
- console.log('Detected 0-based addressing mode (base address: 40000)');
766
- return {
767
- baseAddress: 40000,
768
- isZeroBased: true,
769
- nextAddress: 40002
770
- };
771
- }
797
+ // Standard SunSpec root probe. Runs when no custom base was given, OR as the fallback
798
+ // when the custom base carried no marker. Try 1-based (40001) first (most common), then
799
+ // 0-based (40000).
800
+ try {
801
+ const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40001, 2));
802
+ if (sunspecId.includes('SunS')) {
803
+ console.log('Detected 1-based addressing mode (base address: 40001)');
804
+ return {
805
+ baseAddress: 40001,
806
+ isZeroBased: false,
807
+ nextAddress: 40003
808
+ };
772
809
  }
773
- catch (error) {
774
- console.debug('Could not read SunS at 40000:', error);
810
+ }
811
+ catch (error) {
812
+ console.debug('Could not read SunS at 40001:', error);
813
+ }
814
+ // Try 0-based addressing
815
+ try {
816
+ const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40000, 2));
817
+ if (sunspecId.includes('SunS')) {
818
+ console.log('Detected 0-based addressing mode (base address: 40000)');
819
+ return {
820
+ baseAddress: 40000,
821
+ isZeroBased: true,
822
+ nextAddress: 40002
823
+ };
775
824
  }
776
825
  }
826
+ catch (error) {
827
+ console.debug('Could not read SunS at 40000:', error);
828
+ }
777
829
  const addressesChecked = customBaseAddress !== undefined
778
- ? `${customBaseAddress}, ${customBaseAddress + 1}`
830
+ ? `${customBaseAddress}, ${customBaseAddress + 1}, 40001, 40000`
779
831
  : '40000 or 40001';
780
832
  throw new Error(`Device is not SunSpec compliant - "SunS" identifier not found at addresses ${addressesChecked}`);
781
833
  }
@@ -786,29 +838,35 @@ class SunspecModbusClient {
786
838
  async discoverModels(unitId, customBaseAddress) {
787
839
  const instance = this.getInstance(unitId);
788
840
  const models = this.getModelsMap(unitId);
789
- models.clear();
790
841
  const modelList = this.getModelList(unitId);
791
- modelList.length = 0;
792
842
  const maxAddress = 50000; // Safety limit
793
- let currentAddress = 0;
794
843
  console.log(`Starting Sunspec model discovery for unit ${unitId}...`);
795
844
  // Probe for the SunS identifier first. A missing identifier means the unit ID isn't a
796
845
  // SunSpec device — common during unit-ID scans — and is logged at debug level so probes
797
846
  // don't surface as errors. Mid-scan failures below remain at error level since they
798
847
  // indicate a partial / malformed SunSpec map.
848
+ //
849
+ // IMPORTANT: we discover into TEMP buffers and only commit into the stored map once the
850
+ // walk yields at least one model. A reconnect probe can transiently fail (e.g. a single-
851
+ // session SolarEdge endpoint drops the socket with ECONNRESET on the first read after
852
+ // accepting the connection). Clearing the stored map up-front — as this used to — turned
853
+ // that blip into "no usable models", which trips tryReconnect()'s gate into invalidating
854
+ // a unit whose model map was perfectly good a moment ago. Preserving the last known-good
855
+ // map keeps a genuinely-connected sibling alive; a device that is really gone is still
856
+ // caught by read-health (isHealthy()).
799
857
  let addressInfo;
800
858
  try {
801
859
  addressInfo = await this.detectSunspecBaseAddress(unitId, customBaseAddress);
802
860
  }
803
861
  catch (error) {
804
862
  console.debug(`No SunSpec device at unit ${unitId}: ${error}`);
805
- // Discovery summary at line 594 below is the info-level outcome.
806
- // This 0-models branch is the same outcome as a normal "no device found",
807
- // covered already by the debug above. Keep at debug.
808
- console.debug(`Discovery complete for unit ${unitId}. Found 0 models: []`);
863
+ // Same outcome as a normal "no device found"; keep at debug. Do NOT wipe the stored
864
+ // map — return it untouched so a transient probe failure can't erase good discovery.
865
+ console.debug(`Discovery incomplete for unit ${unitId}; keeping ${models.size} previously-discovered model(s).`);
809
866
  return models;
810
867
  }
811
- currentAddress = addressInfo.nextAddress;
868
+ const discovered = [];
869
+ let currentAddress = addressInfo.nextAddress;
812
870
  try {
813
871
  while (currentAddress < maxAddress) {
814
872
  const buffer = await this.runExclusive(unitId, () => instance.readHoldingRegisters(currentAddress, 2));
@@ -824,19 +882,12 @@ class SunspecModbusClient {
824
882
  console.debug(`Found end marker at address ${currentAddress}`);
825
883
  break;
826
884
  }
827
- // Store discovered model
828
885
  const model = {
829
886
  id: modelId,
830
887
  address: currentAddress,
831
888
  length: modelLength
832
889
  };
833
- // Keep the FIRST (lowest-address) instance per id in the keyed directory so
834
- // findModel() resolves to the device's own block. Record every instance —
835
- // including repeats like a meter's Common (id 1) — in the ordered list.
836
- if (!models.has(modelId)) {
837
- models.set(modelId, model);
838
- }
839
- modelList.push(model);
890
+ discovered.push(model);
840
891
  // Per-model discovery step. The end-of-discovery summary below is the
841
892
  // info-level outcome; the per-model walk is debug-only.
842
893
  console.debug(`Discovered Model ${modelId} at address ${currentAddress} with length ${modelLength} (unit ${unitId})`);
@@ -847,6 +898,24 @@ class SunspecModbusClient {
847
898
  catch (error) {
848
899
  console.error(`Error during model discovery at address ${currentAddress} (unit ${unitId}): ${error}`);
849
900
  }
901
+ if (discovered.length > 0) {
902
+ // Commit the fresh discovery atomically. Keep the FIRST (lowest-address) instance per
903
+ // id in the keyed directory so findModel() resolves to the device's own block; record
904
+ // every instance — including repeats like a meter's Common (id 1) — in the ordered list.
905
+ models.clear();
906
+ modelList.length = 0;
907
+ for (const model of discovered) {
908
+ if (!models.has(model.id)) {
909
+ models.set(model.id, model);
910
+ }
911
+ modelList.push(model);
912
+ }
913
+ }
914
+ else {
915
+ // The anchor answered but the walk yielded nothing (e.g. the socket dropped right
916
+ // after the SunS probe). Preserve the last known-good map rather than clobbering it.
917
+ console.debug(`Discovery for unit ${unitId} yielded no models; keeping ${models.size} previously-discovered model(s).`);
918
+ }
850
919
  // Report every instance in address order so repeated ids (e.g. two Common blocks, or
851
920
  // multiple meters) are visible — models.size would hide them behind the unique keys.
852
921
  console.log(`Discovery complete for unit ${unitId}. Found ${modelList.length} model instance(s): [${modelList.map(m => m.id).join(', ')}]`);
@@ -988,12 +1057,87 @@ class SunspecModbusClient {
988
1057
  return value;
989
1058
  }
990
1059
  /**
991
- * Helper to read register value(s) using the fault-tolerant reader with data type conversion
1060
+ * Read a contiguous span of `quantity` registers starting at `address` in a single logical
1061
+ * transaction — chunked at the 125-register Modbus limit and serialized on the unit's socket so no
1062
+ * other frame interleaves between chunks. FC03 holding registers by default; FC04 input registers
1063
+ * when `useInputRegisters` is true. The SunSpec model readers use {@link readModelBlock}; this is
1064
+ * the equivalent for callers reading a hand-defined block (see {@link SunspecCustomDevice}). Decode
1065
+ * individual fields out of the returned buffer with {@link decodeBlockValue}.
1066
+ */
1067
+ async readRegisterBlock(unitId, address, quantity, useInputRegisters = false) {
1068
+ const reader = this.getReader(unitId);
1069
+ const MAX_REGISTERS_PER_READ = 125;
1070
+ try {
1071
+ const chunks = await this.runExclusive(unitId, async () => {
1072
+ const acc = [];
1073
+ for (let offset = 0; offset < quantity; offset += MAX_REGISTERS_PER_READ) {
1074
+ const count = Math.min(MAX_REGISTERS_PER_READ, quantity - offset);
1075
+ let result;
1076
+ if (useInputRegisters) {
1077
+ if (!reader.readInputRegisters) {
1078
+ throw new Error(`Reader for unit ${unitId} does not support FC04 input registers`);
1079
+ }
1080
+ result = await reader.readInputRegisters(address + offset, count);
1081
+ }
1082
+ else {
1083
+ result = await reader.readHoldingRegisters(address + offset, count);
1084
+ }
1085
+ if (!result.success || !result.value) {
1086
+ throw new Error(`Failed to read register block at address ${address + offset} (unit ${unitId}): ${result.error?.message || 'Unknown error'}`);
1087
+ }
1088
+ acc.push(result.value);
1089
+ }
1090
+ return acc;
1091
+ });
1092
+ this.connectionHealth.recordSuccess();
1093
+ return chunks.length === 1 ? chunks[0] : Buffer.concat(chunks);
1094
+ }
1095
+ catch (error) {
1096
+ this.connectionHealth.recordFailure(error);
1097
+ throw error;
1098
+ }
1099
+ }
1100
+ /**
1101
+ * Decode a typed value out of a buffer returned by {@link readRegisterBlock}, at a register offset
1102
+ * from the block start. A thin public wrapper over the same block-extraction the SunSpec model
1103
+ * readers use internally.
1104
+ */
1105
+ decodeBlockValue(buffer, registerOffset, dataType, quantity = 1) {
1106
+ return this.extractValue(buffer, registerOffset, dataType, quantity);
1107
+ }
1108
+ /**
1109
+ * Helper to read holding register value(s) (FC03) using the fault-tolerant reader with data type
1110
+ * conversion.
992
1111
  */
993
1112
  async readRegisterValue(unitId, address, quantity = 1, dataType) {
1113
+ return this.readTypedRegisters(unitId, address, quantity, dataType, false);
1114
+ }
1115
+ /**
1116
+ * Helper to read input register value(s) (FC04) using the fault-tolerant reader with data type
1117
+ * conversion. SunSpec itself never uses input registers, but plain-Modbus devices behind a
1118
+ * {@link SunspecCustomDevice} may expose live values there. Throws if the transport's reader does
1119
+ * not implement `readInputRegisters`.
1120
+ */
1121
+ async readInputRegisterValue(unitId, address, quantity = 1, dataType) {
1122
+ return this.readTypedRegisters(unitId, address, quantity, dataType, true);
1123
+ }
1124
+ /**
1125
+ * Shared body of {@link readRegisterValue} / {@link readInputRegisterValue}. Runs the read under
1126
+ * the unit's transaction lock (so it inherits the timeout/poison/staleness resilience) and records
1127
+ * connection health on both success and failure.
1128
+ */
1129
+ async readTypedRegisters(unitId, address, quantity, dataType, useInputRegisters) {
994
1130
  const reader = this.getReader(unitId);
995
1131
  try {
996
- const result = await this.runExclusive(unitId, () => reader.readHoldingRegisters(address, quantity));
1132
+ const result = await this.runExclusive(unitId, () => {
1133
+ if (useInputRegisters) {
1134
+ if (!reader.readInputRegisters) {
1135
+ throw new Error(`Reader for unit ${unitId} does not support FC04 input registers`);
1136
+ }
1137
+ return reader.readInputRegisters(address, quantity);
1138
+ }
1139
+ return reader.readHoldingRegisters(address, quantity);
1140
+ });
997
1141
  // Check if the read was successful
998
1142
  if (!result.success || !result.value) {
999
1143
  throw new Error(`Failed to read register at address ${address}: ${result.error?.message || 'Unknown error'}`);
@@ -152,6 +152,15 @@ export declare class SunspecModbusClient {
152
152
  * if every unit succeeded.
153
153
  */
154
154
  private attemptConnection;
155
+ /**
156
+ * Build the ordered host list handed to the transport's `host` option for a single connect.
157
+ * The attempt's primary target leads, followed by every OTHER known host (the other of
158
+ * primaryHost/secondaryHost) as an in-band fallback the transport walks in order — so a stale
159
+ * DNS name or a DHCP-changed IP on the first host is tolerated within one connect() instead of
160
+ * only via the client's sequential primary→secondary retry. Deduped; returns a bare string when
161
+ * no distinct fallback exists, leaving single-host devices (and their tests) unaffected.
162
+ */
163
+ private buildConnectHosts;
155
164
  /**
156
165
  * Open a unit, retrying the connect on a transient failure per the resilience config
157
166
  * ({@link IModbusResilienceConfig.connectRetries}). Each attempt is a full {@link _openUnitOnce}
@@ -167,6 +176,14 @@ export declare class SunspecModbusClient {
167
176
  * Open a new Modbus instance for one unit ID and wire up its fault-tolerant reader. Bounds the
168
177
  * connect at `connectTimeoutMs`. On any failure, the just-opened instance (if any) is closed so
169
178
  * we never leak. Caller must hold the connection lock and ensure the unit is not already open.
179
+ *
180
+ * When `useFallbackHosts` is true (the connect/reconnect default), the transport is handed the
181
+ * full host list from {@link buildConnectHosts} — the attempt's primary target plus the other
182
+ * known host — so one connect() tolerates DNS/DHCP drift on the first host in-band, rather than
183
+ * waiting for the client's own sequential primary→secondary retry. The transport walks the list
184
+ * in order, each host bounded by `timeout` (connectTimeoutMs); we scale our own outer budget by
185
+ * the host count so a legitimate multi-host walk isn't aborted mid-fallback. probeUnit passes
186
+ * false to keep speculative RS485 scans a fast-fail single-host probe.
170
187
  */
171
188
  private _openUnitOnce;
172
189
  /**
@@ -349,9 +366,38 @@ export declare class SunspecModbusClient {
349
366
  */
350
367
  private extractValue;
351
368
  /**
352
- * Helper to read register value(s) using the fault-tolerant reader with data type conversion
369
+ * Read a contiguous span of `quantity` registers starting at `address` in a single logical
370
+ * transaction — chunked at the 125-register Modbus limit and serialized on the unit's socket so no
371
+ * other frame interleaves between chunks. FC03 holding registers by default; FC04 input registers
372
+ * when `useInputRegisters` is true. The SunSpec model readers use {@link readModelBlock}; this is
373
+ * the equivalent for callers reading a hand-defined block (see {@link SunspecCustomDevice}). Decode
374
+ * individual fields out of the returned buffer with {@link decodeBlockValue}.
375
+ */
376
+ readRegisterBlock(unitId: number, address: number, quantity: number, useInputRegisters?: boolean): Promise<Buffer>;
377
+ /**
378
+ * Decode a typed value out of a buffer returned by {@link readRegisterBlock}, at a register offset
379
+ * from the block start. A thin public wrapper over the same block-extraction the SunSpec model
380
+ * readers use internally.
381
+ */
382
+ decodeBlockValue(buffer: Buffer, registerOffset: number, dataType: EnergyAppModbusDataType, quantity?: number): number | string | number[];
383
+ /**
384
+ * Helper to read holding register value(s) (FC03) using the fault-tolerant reader with data type
385
+ * conversion.
353
386
  */
354
387
  readRegisterValue(unitId: number, address: number, quantity: number | undefined, dataType: EnergyAppModbusDataType): Promise<number | string | number[]>;
388
+ /**
389
+ * Helper to read input register value(s) (FC04) using the fault-tolerant reader with data type
390
+ * conversion. SunSpec itself never uses input registers, but plain-Modbus devices behind a
391
+ * {@link SunspecCustomDevice} may expose live values there. Throws if the transport's reader does
392
+ * not implement `readInputRegisters`.
393
+ */
394
+ readInputRegisterValue(unitId: number, address: number, quantity: number | undefined, dataType: EnergyAppModbusDataType): Promise<number | string | number[]>;
395
+ /**
396
+ * Shared body of {@link readRegisterValue} / {@link readInputRegisterValue}. Runs the read under
397
+ * the unit's transaction lock (so it inherits the timeout/poison/staleness resilience) and records
398
+ * connection health on both success and failure.
399
+ */
400
+ private readTypedRegisters;
355
401
  /**
356
402
  * Helper to write register value(s)
357
403
  */
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
9
9
  /**
10
10
  * Current version of the enyo Energy App SDK.
11
11
  */
12
- exports.SDK_VERSION = '0.0.101';
12
+ exports.SDK_VERSION = '0.0.103';
13
13
  /**
14
14
  * Gets the current SDK version.
15
15
  * @returns The semantic version string of the SDK
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.101";
8
+ export declare const SDK_VERSION = "0.0.103";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK