@enyo-energy/sunspec-sdk 0.0.101 → 0.0.103

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -1,6 +1,6 @@
1
1
  "use strict";
2
2
  Object.defineProperty(exports, "__esModule", { value: true });
3
- exports.SunspecMeter = exports.SunspecBattery = exports.SunspecInverter = exports.BaseSunspecDevice = void 0;
3
+ exports.SunspecCustomDevice = exports.SunspecMeter = exports.SunspecBattery = exports.SunspecInverter = exports.BaseSunspecDevice = void 0;
4
4
  exports.detectFeaturesFromRegisters = detectFeaturesFromRegisters;
5
5
  exports.sumMpptBatteryPowerW = sumMpptBatteryPowerW;
6
6
  exports.selectLiveBatteryPowerW = selectLiveBatteryPowerW;
@@ -117,6 +117,19 @@ class BaseSunspecDevice {
117
117
  * would otherwise stay Offline forever despite reading data fine.
118
118
  */
119
119
  appliedOffline = false;
120
+ /**
121
+ * True once {@link reassertConnectedIfRecovered} has confirmed (via the
122
+ * appliance store) that this device is Connected, so it can stop probing
123
+ * for an *externally* applied Offline state. Distinct from
124
+ * {@link appliedOffline}, which only tracks Offline states this SDK object
125
+ * applied itself. An appliance can be marked Offline by a path outside the
126
+ * SDK object — e.g. the energy-app registering a boot-time offline
127
+ * placeholder before this device came up on a shared socket — which never
128
+ * sets appliedOffline; without reconciling against actual state, such a
129
+ * device stays Offline forever despite reading data fine. Reset in
130
+ * {@link markOffline} so a later Offline episode is re-checked.
131
+ */
132
+ reconciledExternalOffline = false;
120
133
  /**
121
134
  * Prefix used when persisting calibration snapshots via the library's
122
135
  * {@link SnapshotService}. Kept identical to the key the SDK used before
@@ -156,9 +169,33 @@ class BaseSunspecDevice {
156
169
  await this.sunspecClient.connect(this.networkDevice.hostname, // primary
157
170
  this.port, this.unitId, this.networkDevice.ipAddress, // secondary fallback
158
171
  this.useTls);
159
- await this.sunspecClient.discoverModels(this.unitId, this.baseAddress);
172
+ await this.discoverAfterConnect();
160
173
  }
161
174
  }
175
+ /**
176
+ * Populate the per-unit model directory after the socket opens. Default: run SunSpec model
177
+ * discovery. Devices that read a hand-defined static register map instead of a discovered SunSpec
178
+ * directory (see {@link SunspecCustomDevice}) override this to a no-op.
179
+ */
180
+ async discoverAfterConnect() {
181
+ await this.sunspecClient.discoverModels(this.unitId, this.baseAddress);
182
+ }
183
+ /**
184
+ * Validate that a just-completed reconnect actually restored a usable device. Default: re-run
185
+ * SunSpec discovery and check it against {@link getRequiredModelIds} (a socket that opens but comes
186
+ * back with no usable models means the gateway accepted the connection before it was ready to
187
+ * answer the scan). Returns false to treat the reconnect as failed so the backoff schedule keeps
188
+ * running. Discovery-less devices override this to just confirm the socket is open.
189
+ */
190
+ async revalidateAfterReconnect() {
191
+ const models = await this.sunspecClient.discoverModels(this.unitId, this.baseAddress);
192
+ const usable = this.isDiscoveryUsable(models);
193
+ if (!usable) {
194
+ console.warn(`${this.constructor.name} ${this.applianceId}: reconnect discovery returned no usable models ` +
195
+ `(found [${[...models.keys()].join(', ')}])`);
196
+ }
197
+ return usable;
198
+ }
162
199
  /**
163
200
  * Attempt a reconnection if the tiered retry schedule allows it.
164
201
  * Called from readData() when the device is disconnected.
@@ -193,14 +230,12 @@ class BaseSunspecDevice {
193
230
  // it's unusable, treat this as a failed reconnect: invalidate the socket so the
194
231
  // next poll re-enters tryReconnect(), keep the backoff schedule running, and do
195
232
  // NOT reset().
196
- const models = await this.sunspecClient.discoverModels(this.unitId, this.baseAddress);
197
- if (!this.isDiscoveryUsable(models)) {
198
- this.sunspecClient.invalidateUnit(this.unitId, `reconnect discovery found no usable models for unit ${this.unitId}`);
233
+ if (!(await this.revalidateAfterReconnect())) {
234
+ this.sunspecClient.invalidateUnit(this.unitId, `reconnect revalidation failed for unit ${this.unitId}`);
199
235
  this.consecutiveReconnectFailures += 1;
200
236
  await this.onConnectionFailure(this.consecutiveReconnectFailures);
201
237
  console.warn(`${this.constructor.name} ${this.applianceId}: Reconnect attempt #${attempt} ` +
202
- `opened the socket but discovery returned no usable models ` +
203
- `(found [${[...models.keys()].join(', ')}]) — retrying with backoff`);
238
+ `opened the socket but revalidation failed — retrying with backoff`);
204
239
  return false;
205
240
  }
206
241
  this.retryManager.reset();
@@ -315,6 +350,7 @@ class BaseSunspecDevice {
315
350
  try {
316
351
  await this.applianceManager.updateApplianceState(this.applianceId, enyo_appliance_js_1.EnyoApplianceConnectionType.Connector, enyo_appliance_js_1.EnyoApplianceStateEnum.Offline);
317
352
  this.appliedOffline = true;
353
+ this.reconciledExternalOffline = false;
318
354
  }
319
355
  catch (error) {
320
356
  console.error(`${this.constructor.name} ${this.applianceId}: Failed to mark appliance offline: ${error}`);
@@ -330,17 +366,45 @@ class BaseSunspecDevice {
330
366
  * readData() and skip tryReconnect() entirely, so without this they would
331
367
  * stay Offline forever despite reading data fine.
332
368
  *
369
+ * Heals two ways an appliance can be stuck Offline while reads succeed:
370
+ * 1. This SDK object marked itself offline ({@link appliedOffline}) and a
371
+ * sibling won the reconnect race — the original shared-socket case.
372
+ * 2. The appliance was marked Offline by a path *outside* this object —
373
+ * e.g. the energy-app registering a boot-time offline placeholder
374
+ * before this device came up on the shared socket — which never sets
375
+ * appliedOffline. We reconcile against the actual stored state so the
376
+ * invariant "healthy reads ⇒ Connected" holds regardless of who
377
+ * applied the Offline.
378
+ *
333
379
  * Call this on the success path of readData() (after the
334
- * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). It is
335
- * a cheap no-op unless this device was previously marked offline.
380
+ * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). Cheap:
381
+ * a no-op via the appliedOffline fast path, and the external-state lookup
382
+ * runs at most once per Offline episode (latched by
383
+ * {@link reconciledExternalOffline} once Connected is confirmed).
336
384
  */
337
385
  async reassertConnectedIfRecovered() {
338
- if (!this.appliedOffline || !this.applianceId) {
386
+ if (!this.applianceId) {
339
387
  return;
340
388
  }
341
389
  if (!this.sunspecClient.isHealthy(this.unitId)) {
342
390
  return;
343
391
  }
392
+ let shouldReassert = this.appliedOffline;
393
+ // Not offline by our own hand: it may still be Offline from an
394
+ // externally applied state. Probe the store once until we confirm
395
+ // Connected, then latch so the steady state adds no extra lookups.
396
+ if (!shouldReassert && !this.reconciledExternalOffline) {
397
+ const appliance = await this.applianceManager.findApplianceById(this.applianceId);
398
+ if (appliance?.metadata?.state === enyo_appliance_js_1.EnyoApplianceStateEnum.Offline) {
399
+ shouldReassert = true;
400
+ }
401
+ else {
402
+ this.reconciledExternalOffline = true;
403
+ }
404
+ }
405
+ if (!shouldReassert) {
406
+ return;
407
+ }
344
408
  console.log(`${this.constructor.name} ${this.applianceId}: connection recovered via shared socket — re-asserting Connected`);
345
409
  try {
346
410
  await this.applianceManager.updateApplianceState(this.applianceId, enyo_appliance_js_1.EnyoApplianceConnectionType.Connector, enyo_appliance_js_1.EnyoApplianceStateEnum.Connected);
@@ -350,6 +414,7 @@ class BaseSunspecDevice {
350
414
  return;
351
415
  }
352
416
  this.appliedOffline = false;
417
+ this.reconciledExternalOffline = true;
353
418
  this.retryManager.reset();
354
419
  this.consecutiveReconnectFailures = 0;
355
420
  await this.onConnectionRestored();
@@ -2242,3 +2307,346 @@ class SunspecMeter extends BaseSunspecDevice {
2242
2307
  }
2243
2308
  }
2244
2309
  exports.SunspecMeter = SunspecMeter;
2310
+ /** Appliance type created for each custom-device role (battery emulates a Storage appliance). */
2311
+ const CUSTOM_ROLE_APPLIANCE_TYPE = {
2312
+ meter: enyo_appliance_js_1.EnyoApplianceTypeEnum.Meter,
2313
+ inverter: enyo_appliance_js_1.EnyoApplianceTypeEnum.Inverter,
2314
+ battery: enyo_appliance_js_1.EnyoApplianceTypeEnum.Storage,
2315
+ };
2316
+ /** Natural register width per data type, used when a register omits an explicit `quantity`. */
2317
+ const CUSTOM_REGISTER_DEFAULT_QUANTITY = {
2318
+ uint16: 1,
2319
+ int16: 1,
2320
+ acc16: 1,
2321
+ uint32: 2,
2322
+ int32: 2,
2323
+ acc32: 2,
2324
+ float32: 2,
2325
+ string: 1,
2326
+ };
2327
+ /** Numeric databus fields a `meter`-role custom device may populate. */
2328
+ const CUSTOM_METER_FIELDS = [
2329
+ 'gridPowerW', 'gridPowerPhase1W', 'gridPowerPhase2W', 'gridPowerPhase3W',
2330
+ 'gridFeedInWh', 'gridConsumptionWh', 'selfConsumptionW', 'selfConsumptionWh',
2331
+ ];
2332
+ /** Numeric databus fields an `inverter`-role custom device may populate. */
2333
+ const CUSTOM_INVERTER_FIELDS = [
2334
+ 'pvPowerW', 'voltageL1', 'voltageL2', 'voltageL3',
2335
+ 'currentL1', 'currentL2', 'currentL3', 'dcPowerW',
2336
+ 'activePowerLimitationW', 'meterValueWh',
2337
+ ];
2338
+ /** Numeric databus fields a `battery`-role custom device may populate. */
2339
+ const CUSTOM_BATTERY_FIELDS = [
2340
+ 'batterySoC', 'batteryPowerW', 'dcStringInputPowerW',
2341
+ ];
2342
+ /** Default {@link SunspecCustomDeviceConfig.blockSize}: the Modbus FC03/FC04 per-read limit. */
2343
+ const CUSTOM_DEFAULT_BLOCK_SIZE = 125;
2344
+ /**
2345
+ * A generic, pre-configured Modbus device that plugs into the exact same resilient lifecycle as the
2346
+ * SunSpec devices — the per-device {@link ConnectionRetryManager}, {@link tryReconnect} tiered backoff,
2347
+ * {@link markOffline}/{@link reassertConnectedIfRecovered} shared-socket healing, and the client's
2348
+ * per-transaction timeout/poison/staleness guards — but reads a **hand-defined static register map**
2349
+ * instead of a discovered SunSpec model directory.
2350
+ *
2351
+ * It emulates a configurable {@link SunspecCustomDeviceConfig.role} (`meter` | `inverter` | `battery`):
2352
+ * the role selects the appliance type created on connect and which EnyoDataBus values message
2353
+ * {@link readData} publishes, and each {@link SunspecCustomRegister} maps onto one numeric field of
2354
+ * that message. Supports FC03 holding registers (default), FC04 input registers, and writes.
2355
+ *
2356
+ * Discovery is fully bypassed: {@link connect} opens the socket only, and the reconnect path is
2357
+ * validated by socket liveness rather than a SunSpec scan.
2358
+ */
2359
+ class SunspecCustomDevice extends BaseSunspecDevice {
2360
+ config;
2361
+ /** Read plan derived once from the static register map (see {@link planBlocks}). */
2362
+ plannedBlocks;
2363
+ constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, config, unitId = 1, port = 502, baseAddress = 40000, retryConfig, appliance, useTls) {
2364
+ super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
2365
+ this.config = config;
2366
+ }
2367
+ /**
2368
+ * No SunSpec model directory to build — this device reads pre-defined static addresses. Overriding
2369
+ * the base discovery hook to a no-op is what lets {@link ensureConnected}/{@link connect} open the
2370
+ * socket without a SunS scan.
2371
+ */
2372
+ async discoverAfterConnect() {
2373
+ // Intentionally empty: plain-Modbus device, no SunSpec discovery.
2374
+ }
2375
+ /**
2376
+ * A reconnect is usable as soon as the socket is open again — there is no model map to revalidate.
2377
+ * Without this override the base default would run SunSpec discovery, find nothing, and treat every
2378
+ * reconnect as a permanent failure.
2379
+ */
2380
+ async revalidateAfterReconnect() {
2381
+ return this.sunspecClient.isConnected(this.unitId);
2382
+ }
2383
+ /**
2384
+ * Connect the underlying socket (no discovery) and create/update the appliance for the configured
2385
+ * role. Identity metadata comes from {@link SunspecCustomDeviceConfig.identity} since there is no
2386
+ * SunSpec Common block to read it from.
2387
+ */
2388
+ async connect() {
2389
+ if (!this.sunspecClient.isConnected(this.unitId)) {
2390
+ await this.sunspecClient.connect(this.networkDevice.hostname, // primary
2391
+ this.port, this.unitId, this.networkDevice.ipAddress, // secondary fallback
2392
+ this.useTls);
2393
+ // No discoverModels(): this device reads a pre-defined static register map.
2394
+ }
2395
+ const applianceType = CUSTOM_ROLE_APPLIANCE_TYPE[this.config.role];
2396
+ if (!this.applianceId) {
2397
+ try {
2398
+ this.applianceId = await this.applianceManager.createOrUpdateAppliance({
2399
+ name: this.name,
2400
+ type: applianceType,
2401
+ networkDevices: [this.networkDevice],
2402
+ metadata: {
2403
+ connectionType: enyo_appliance_js_1.EnyoApplianceConnectionType.Connector,
2404
+ state: enyo_appliance_js_1.EnyoApplianceStateEnum.Connected,
2405
+ serialNumber: this.config.identity?.serialNumber,
2406
+ modelName: this.config.identity?.modelName,
2407
+ vendorName: this.config.identity?.vendorName,
2408
+ modbus: { unitId: this.unitId, baseAddress: this.baseAddress },
2409
+ },
2410
+ });
2411
+ console.log(`Sunspec custom ${this.config.role} connected: ${this.networkDevice.hostname} unit ${this.unitId} (${this.applianceId})`);
2412
+ }
2413
+ catch (error) {
2414
+ console.error(`Failed to create custom ${this.config.role} appliance: ${error}`);
2415
+ }
2416
+ }
2417
+ else {
2418
+ try {
2419
+ const existingAppliance = await this.applianceManager.findApplianceById(this.applianceId);
2420
+ await this.applianceManager.updateAppliance(this.applianceId, {
2421
+ metadata: {
2422
+ ...existingAppliance?.metadata,
2423
+ connectionType: enyo_appliance_js_1.EnyoApplianceConnectionType.Connector,
2424
+ state: enyo_appliance_js_1.EnyoApplianceStateEnum.Connected,
2425
+ modbus: { unitId: this.unitId, baseAddress: this.baseAddress },
2426
+ }
2427
+ });
2428
+ console.log(`Sunspec custom ${this.config.role} connected: ${this.networkDevice.hostname} unit ${this.unitId} (${this.applianceId})`);
2429
+ }
2430
+ catch (error) {
2431
+ console.error(`Failed to update custom ${this.config.role} appliance: ${error}`);
2432
+ }
2433
+ }
2434
+ }
2435
+ async disconnect() {
2436
+ if (this.applianceId) {
2437
+ try {
2438
+ await this.applianceManager.updateApplianceState(this.applianceId, enyo_appliance_js_1.EnyoApplianceConnectionType.Connector, enyo_appliance_js_1.EnyoApplianceStateEnum.Offline);
2439
+ }
2440
+ catch (error) {
2441
+ console.error(`Failed to mark custom ${this.config.role} offline on disconnect: ${error}`);
2442
+ }
2443
+ }
2444
+ // Close just this device's unit; siblings on the same network device stay open.
2445
+ await this.sunspecClient.disconnectUnit(this.unitId);
2446
+ }
2447
+ async readData(clockId, resolution) {
2448
+ if (!this.isConnected()) {
2449
+ await this.tryReconnect();
2450
+ if (!this.isConnected())
2451
+ return [];
2452
+ }
2453
+ const messages = [];
2454
+ const timestamp = new Date();
2455
+ try {
2456
+ const values = await this.readConfiguredRegisters();
2457
+ // readRegisterValue throws on a failed read (unlike the SunSpec model readers), so a dead
2458
+ // socket lands in catch below. This also covers the health-counter path when the transport
2459
+ // records failures without throwing.
2460
+ if (await this.markOfflineIfUnhealthy()) {
2461
+ return messages;
2462
+ }
2463
+ // Healthy read: if a sibling on the same shared socket reconnected us, flip our appliance
2464
+ // state back to Connected. No-op unless this device is still marked offline.
2465
+ await this.reassertConnectedIfRecovered();
2466
+ messages.push(this.buildRoleMessage(values, clockId, resolution, timestamp));
2467
+ this.lastUpdateTime = timestamp.getTime();
2468
+ }
2469
+ catch (error) {
2470
+ console.error(`Error updating custom ${this.config.role} data: ${error}`);
2471
+ await this.markOffline();
2472
+ }
2473
+ return messages;
2474
+ }
2475
+ /**
2476
+ * Write a value to a pre-configured writable register. Delegates to the client's resilient
2477
+ * {@link SunspecModbusClient.writeRegisterValue}.
2478
+ */
2479
+ async writeCustomRegister(name, value) {
2480
+ const reg = this.config.writeRegisters?.find(r => r.name === name);
2481
+ if (!reg) {
2482
+ throw new Error(`No writable register named '${name}' configured for custom ${this.config.role}`);
2483
+ }
2484
+ return this.sunspecClient.writeRegisterValue(this.unitId, reg.address, value, reg.dataType);
2485
+ }
2486
+ /**
2487
+ * Read every configured register as a small number of block reads and extract each register from
2488
+ * its block buffer by offset (mirroring the SunSpec model-block read). Applies the fixed decimal
2489
+ * scaling and returns a field → value map. Non-numeric reads (e.g. a `string` dataType that can't
2490
+ * populate a numeric databus field) are skipped with a warning.
2491
+ */
2492
+ async readConfiguredRegisters() {
2493
+ const values = new Map();
2494
+ for (const block of this.getPlannedBlocks()) {
2495
+ const buffer = await this.sunspecClient.readRegisterBlock(this.unitId, block.startAddress, block.length, block.useInputRegisters);
2496
+ for (const member of block.members) {
2497
+ const raw = this.sunspecClient.decodeBlockValue(buffer, member.offset, member.dataType, member.quantity);
2498
+ if (typeof raw !== 'number') {
2499
+ console.warn(`Custom ${this.config.role}: register '${member.field}' returned a non-numeric value; skipping`);
2500
+ continue;
2501
+ }
2502
+ values.set(member.field, raw * Math.pow(10, member.scaleFactor));
2503
+ }
2504
+ }
2505
+ return values;
2506
+ }
2507
+ /** Lazily compute and cache the block read plan; the register map is static per device. */
2508
+ getPlannedBlocks() {
2509
+ if (!this.plannedBlocks) {
2510
+ this.plannedBlocks = this.planBlocks();
2511
+ }
2512
+ return this.plannedBlocks;
2513
+ }
2514
+ /**
2515
+ * Group the configured registers (separately per function code) sorted by address, coalescing them
2516
+ * — across gaps — into blocks no wider than {@link SunspecCustomDeviceConfig.blockSize}. A new block
2517
+ * starts whenever adding the next register would exceed that span. Each block records its members'
2518
+ * offsets so a single read can be sliced into all of them.
2519
+ */
2520
+ planBlocks() {
2521
+ const blockSize = Math.max(1, this.config.blockSize ?? CUSTOM_DEFAULT_BLOCK_SIZE);
2522
+ const blocks = [];
2523
+ // Group by function code so FC03 and FC04 registers never share a block.
2524
+ const groups = new Map();
2525
+ for (const reg of this.config.registers) {
2526
+ const useInputRegisters = reg.functionCode === 4;
2527
+ const list = groups.get(useInputRegisters);
2528
+ if (list) {
2529
+ list.push(reg);
2530
+ }
2531
+ else {
2532
+ groups.set(useInputRegisters, [reg]);
2533
+ }
2534
+ }
2535
+ for (const [useInputRegisters, regs] of groups) {
2536
+ const spans = regs
2537
+ .map(reg => {
2538
+ const quantity = reg.quantity ?? CUSTOM_REGISTER_DEFAULT_QUANTITY[reg.dataType];
2539
+ return { reg, quantity, start: reg.address, end: reg.address + quantity };
2540
+ })
2541
+ .sort((a, b) => a.start - b.start);
2542
+ let current;
2543
+ let currentEnd = 0;
2544
+ for (const span of spans) {
2545
+ const member = (offset) => ({
2546
+ field: span.reg.field,
2547
+ dataType: span.reg.dataType,
2548
+ quantity: span.quantity,
2549
+ offset,
2550
+ scaleFactor: span.reg.scaleFactor ?? 0,
2551
+ });
2552
+ // Extend the current block only if the whole span (start .. farthest end) still fits
2553
+ // within blockSize. The first register always opens a block (a lone register wider than
2554
+ // blockSize is still read — readRegisterBlock chunks it).
2555
+ const mergedEnd = current ? Math.max(currentEnd, span.end) : span.end;
2556
+ if (current && mergedEnd - current.startAddress <= blockSize) {
2557
+ current.members.push(member(span.start - current.startAddress));
2558
+ currentEnd = mergedEnd;
2559
+ current.length = currentEnd - current.startAddress;
2560
+ }
2561
+ else {
2562
+ current = {
2563
+ useInputRegisters,
2564
+ startAddress: span.start,
2565
+ length: span.end - span.start,
2566
+ members: [member(0)],
2567
+ };
2568
+ currentEnd = span.end;
2569
+ blocks.push(current);
2570
+ }
2571
+ }
2572
+ }
2573
+ return blocks;
2574
+ }
2575
+ buildRoleMessage(values, clockId, resolution, timestamp) {
2576
+ switch (this.config.role) {
2577
+ case 'meter':
2578
+ return this.buildMeterMessage(values, clockId, resolution, timestamp);
2579
+ case 'inverter':
2580
+ return this.buildInverterMessage(values, clockId, resolution, timestamp);
2581
+ case 'battery':
2582
+ return this.buildBatteryMessage(values, clockId, resolution, timestamp);
2583
+ }
2584
+ }
2585
+ buildMeterMessage(values, clockId, resolution, timestamp) {
2586
+ const data = { gridFeedInWh: 0, gridConsumptionWh: 0 };
2587
+ for (const field of CUSTOM_METER_FIELDS) {
2588
+ const v = values.get(field);
2589
+ if (v !== undefined) {
2590
+ data[field] = v;
2591
+ }
2592
+ }
2593
+ return {
2594
+ id: (0, node_crypto_1.randomUUID)(),
2595
+ message: enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.MeterValuesUpdateV1,
2596
+ type: 'message',
2597
+ source: enyo_source_enum_js_1.EnyoSourceEnum.Device,
2598
+ applianceId: this.applianceId,
2599
+ clockId,
2600
+ timestampIso: timestamp.toISOString(),
2601
+ resolution,
2602
+ data,
2603
+ };
2604
+ }
2605
+ buildInverterMessage(values, clockId, resolution, timestamp) {
2606
+ const data = { pvPowerW: 0, voltageL1: 0 };
2607
+ for (const field of CUSTOM_INVERTER_FIELDS) {
2608
+ const v = values.get(field);
2609
+ if (v !== undefined) {
2610
+ data[field] = v;
2611
+ }
2612
+ }
2613
+ if (this.config.defaultInverterState !== undefined) {
2614
+ data.state = this.config.defaultInverterState;
2615
+ }
2616
+ return {
2617
+ id: (0, node_crypto_1.randomUUID)(),
2618
+ message: enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.InverterValuesUpdateV1,
2619
+ type: 'message',
2620
+ source: enyo_source_enum_js_1.EnyoSourceEnum.Device,
2621
+ applianceId: this.applianceId,
2622
+ clockId,
2623
+ timestampIso: timestamp.toISOString(),
2624
+ resolution,
2625
+ data,
2626
+ };
2627
+ }
2628
+ buildBatteryMessage(values, clockId, resolution, timestamp) {
2629
+ const data = { batterySoC: 0 };
2630
+ for (const field of CUSTOM_BATTERY_FIELDS) {
2631
+ const v = values.get(field);
2632
+ if (v !== undefined) {
2633
+ data[field] = v;
2634
+ }
2635
+ }
2636
+ if (this.config.defaultBatteryState !== undefined) {
2637
+ data.state = this.config.defaultBatteryState;
2638
+ }
2639
+ return {
2640
+ id: (0, node_crypto_1.randomUUID)(),
2641
+ message: enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.BatteryValuesUpdateV1,
2642
+ type: 'message',
2643
+ source: enyo_source_enum_js_1.EnyoSourceEnum.Device,
2644
+ applianceId: this.applianceId,
2645
+ clockId,
2646
+ timestampIso: timestamp.toISOString(),
2647
+ resolution,
2648
+ data,
2649
+ };
2650
+ }
2651
+ }
2652
+ exports.SunspecCustomDevice = SunspecCustomDevice;
@@ -1,4 +1,4 @@
1
- import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.cjs";
1
+ import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.cjs";
2
2
  import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
3
3
  import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
4
4
  import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
@@ -37,6 +37,19 @@ export declare abstract class BaseSunspecDevice {
37
37
  * would otherwise stay Offline forever despite reading data fine.
38
38
  */
39
39
  private appliedOffline;
40
+ /**
41
+ * True once {@link reassertConnectedIfRecovered} has confirmed (via the
42
+ * appliance store) that this device is Connected, so it can stop probing
43
+ * for an *externally* applied Offline state. Distinct from
44
+ * {@link appliedOffline}, which only tracks Offline states this SDK object
45
+ * applied itself. An appliance can be marked Offline by a path outside the
46
+ * SDK object — e.g. the energy-app registering a boot-time offline
47
+ * placeholder before this device came up on a shared socket — which never
48
+ * sets appliedOffline; without reconciling against actual state, such a
49
+ * device stays Offline forever despite reading data fine. Reset in
50
+ * {@link markOffline} so a later Offline episode is re-checked.
51
+ */
52
+ private reconciledExternalOffline;
40
53
  /**
41
54
  * Prefix used when persisting calibration snapshots via the library's
42
55
  * {@link SnapshotService}. Kept identical to the key the SDK used before
@@ -68,6 +81,20 @@ export declare abstract class BaseSunspecDevice {
68
81
  * Ensure the Sunspec client is connected and models are discovered
69
82
  */
70
83
  protected ensureConnected(): Promise<void>;
84
+ /**
85
+ * Populate the per-unit model directory after the socket opens. Default: run SunSpec model
86
+ * discovery. Devices that read a hand-defined static register map instead of a discovered SunSpec
87
+ * directory (see {@link SunspecCustomDevice}) override this to a no-op.
88
+ */
89
+ protected discoverAfterConnect(): Promise<void>;
90
+ /**
91
+ * Validate that a just-completed reconnect actually restored a usable device. Default: re-run
92
+ * SunSpec discovery and check it against {@link getRequiredModelIds} (a socket that opens but comes
93
+ * back with no usable models means the gateway accepted the connection before it was ready to
94
+ * answer the scan). Returns false to treat the reconnect as failed so the backoff schedule keeps
95
+ * running. Discovery-less devices override this to just confirm the socket is open.
96
+ */
97
+ protected revalidateAfterReconnect(): Promise<boolean>;
71
98
  /**
72
99
  * Attempt a reconnection if the tiered retry schedule allows it.
73
100
  * Called from readData() when the device is disconnected.
@@ -138,9 +165,21 @@ export declare abstract class BaseSunspecDevice {
138
165
  * readData() and skip tryReconnect() entirely, so without this they would
139
166
  * stay Offline forever despite reading data fine.
140
167
  *
168
+ * Heals two ways an appliance can be stuck Offline while reads succeed:
169
+ * 1. This SDK object marked itself offline ({@link appliedOffline}) and a
170
+ * sibling won the reconnect race — the original shared-socket case.
171
+ * 2. The appliance was marked Offline by a path *outside* this object —
172
+ * e.g. the energy-app registering a boot-time offline placeholder
173
+ * before this device came up on the shared socket — which never sets
174
+ * appliedOffline. We reconcile against the actual stored state so the
175
+ * invariant "healthy reads ⇒ Connected" holds regardless of who
176
+ * applied the Offline.
177
+ *
141
178
  * Call this on the success path of readData() (after the
142
- * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). It is
143
- * a cheap no-op unless this device was previously marked offline.
179
+ * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). Cheap:
180
+ * a no-op via the appliedOffline fast path, and the external-state lookup
181
+ * runs at most once per Offline episode (latched by
182
+ * {@link reconciledExternalOffline} once Connected is confirmed).
144
183
  */
145
184
  protected reassertConnectedIfRecovered(): Promise<void>;
146
185
  protected sendCommandAcknowledge(messageId: string, acknowledgeMessage: EnyoDataBusMessageEnum | string, answer: EnyoCommandAcknowledgeAnswerEnum, rejectionReason?: string): void;
@@ -735,4 +774,70 @@ export declare class SunspecMeter extends BaseSunspecDevice {
735
774
  */
736
775
  readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
737
776
  }
777
+ /**
778
+ * A generic, pre-configured Modbus device that plugs into the exact same resilient lifecycle as the
779
+ * SunSpec devices — the per-device {@link ConnectionRetryManager}, {@link tryReconnect} tiered backoff,
780
+ * {@link markOffline}/{@link reassertConnectedIfRecovered} shared-socket healing, and the client's
781
+ * per-transaction timeout/poison/staleness guards — but reads a **hand-defined static register map**
782
+ * instead of a discovered SunSpec model directory.
783
+ *
784
+ * It emulates a configurable {@link SunspecCustomDeviceConfig.role} (`meter` | `inverter` | `battery`):
785
+ * the role selects the appliance type created on connect and which EnyoDataBus values message
786
+ * {@link readData} publishes, and each {@link SunspecCustomRegister} maps onto one numeric field of
787
+ * that message. Supports FC03 holding registers (default), FC04 input registers, and writes.
788
+ *
789
+ * Discovery is fully bypassed: {@link connect} opens the socket only, and the reconnect path is
790
+ * validated by socket liveness rather than a SunSpec scan.
791
+ */
792
+ export declare class SunspecCustomDevice extends BaseSunspecDevice {
793
+ private readonly config;
794
+ /** Read plan derived once from the static register map (see {@link planBlocks}). */
795
+ private plannedBlocks?;
796
+ constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, config: SunspecCustomDeviceConfig, unitId?: number, port?: number, baseAddress?: number, retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
797
+ /**
798
+ * No SunSpec model directory to build — this device reads pre-defined static addresses. Overriding
799
+ * the base discovery hook to a no-op is what lets {@link ensureConnected}/{@link connect} open the
800
+ * socket without a SunS scan.
801
+ */
802
+ protected discoverAfterConnect(): Promise<void>;
803
+ /**
804
+ * A reconnect is usable as soon as the socket is open again — there is no model map to revalidate.
805
+ * Without this override the base default would run SunSpec discovery, find nothing, and treat every
806
+ * reconnect as a permanent failure.
807
+ */
808
+ protected revalidateAfterReconnect(): Promise<boolean>;
809
+ /**
810
+ * Connect the underlying socket (no discovery) and create/update the appliance for the configured
811
+ * role. Identity metadata comes from {@link SunspecCustomDeviceConfig.identity} since there is no
812
+ * SunSpec Common block to read it from.
813
+ */
814
+ connect(): Promise<void>;
815
+ disconnect(): Promise<void>;
816
+ readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
817
+ /**
818
+ * Write a value to a pre-configured writable register. Delegates to the client's resilient
819
+ * {@link SunspecModbusClient.writeRegisterValue}.
820
+ */
821
+ writeCustomRegister(name: string, value: number | number[]): Promise<boolean>;
822
+ /**
823
+ * Read every configured register as a small number of block reads and extract each register from
824
+ * its block buffer by offset (mirroring the SunSpec model-block read). Applies the fixed decimal
825
+ * scaling and returns a field → value map. Non-numeric reads (e.g. a `string` dataType that can't
826
+ * populate a numeric databus field) are skipped with a warning.
827
+ */
828
+ private readConfiguredRegisters;
829
+ /** Lazily compute and cache the block read plan; the register map is static per device. */
830
+ private getPlannedBlocks;
831
+ /**
832
+ * Group the configured registers (separately per function code) sorted by address, coalescing them
833
+ * — across gaps — into blocks no wider than {@link SunspecCustomDeviceConfig.blockSize}. A new block
834
+ * starts whenever adding the next register would exceed that span. Each block records its members'
835
+ * offsets so a single read can be sliced into all of them.
836
+ */
837
+ private planBlocks;
838
+ private buildRoleMessage;
839
+ private buildMeterMessage;
840
+ private buildInverterMessage;
841
+ private buildBatteryMessage;
842
+ }
738
843
  export {};