urbanopt-cli 0.5.1 → 0.5.2
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/CHANGELOG.md +14 -1
- data/CMakeLists.txt +8 -8
- data/LICENSE.md +11 -1
- data/Rakefile +16 -6
- data/example_files/example_project_combined.json +100 -5
- data/example_files/mappers/Baseline.rb +31 -18
- data/example_files/mappers/CreateBar.rb +16 -6
- data/example_files/mappers/EvCharging.rb +20 -10
- data/example_files/mappers/Floorspace.rb +16 -6
- data/example_files/mappers/HighEfficiencyCreateBar.rb +16 -6
- data/example_files/mappers/HighEfficiencyFloorspace.rb +16 -6
- data/example_files/mappers/ThermalStorage.rb +16 -6
- data/example_files/measures/BuildResidentialModel/measure.rb +211 -129
- data/example_files/residential/clothes_dryer.tsv +7 -7
- data/example_files/residential/clothes_washer.tsv +1 -1
- data/example_files/residential/cooling_system.tsv +42 -22
- data/example_files/residential/dishwasher.tsv +1 -1
- data/example_files/residential/exhaust.tsv +3 -0
- data/example_files/residential/heat_pump.tsv +62 -40
- data/example_files/resources/hpxml-measures/.github/pull_request_template.md +1 -0
- data/example_files/resources/hpxml-measures/.github/workflows/config.yml +23 -0
- data/example_files/resources/hpxml-measures/.gitignore +1 -8
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.rb +633 -1188
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.xml +1524 -1211
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/constants.rb +0 -8
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/geometry.rb +424 -335
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules.rb +104 -62
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_weekday_state_and_monthly_schedule_shift.csv +613 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/schedules_weekend_state_and_monthly_schedule_shift.csv +613 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-coal.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-dehumidifier-50percent.osw +30 -54
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-dehumidifier-ief-portable.osw +30 -54
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-dehumidifier-ief-whole-home.osw +30 -54
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-dehumidifier.osw +30 -54
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-gas.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-modified.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-none.osw +36 -60
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-oil.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-propane.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-appliances-wood.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-flat.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-radiant-barrier.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-unvented-insulated-roof.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-atticroof-vented.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-mechvent-preconditioning.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-mechvent.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-pv.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily-shared-water-heater.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-multifamily.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-bldgtype-single-family-attached.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-combi-tankless-outside.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-combi-tankless.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-dwhr.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-outside.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-standbyloss.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect-with-solar-fraction.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-indirect.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-electric.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-gas.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-hpwh.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-jacket-indirect.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-low-flow-fixtures.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-none.osw +32 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-demand.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-manual.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-nocontrol.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-temperature.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-recirc-timer.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-evacuated-tube.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-flat-plate.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-direct-ics.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-fraction.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-indirect-flat-plate.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-solar-thermosyphon-flat-plate.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-coal.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-elec-uef.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas-outside.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas-uef.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-gas.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-outside.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-uef.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-with-solar-fraction.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump-with-solar.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-heat-pump.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-oil.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tank-wood.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric-outside.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric-uef.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-electric.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-uef.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-with-solar-fraction.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas-with-solar.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-gas.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-dhw-tankless-propane.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-2stories-garage.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-2stories.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-1.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-2.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-4.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-beds-5.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-garage.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-ach-house-pressure.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-cfm-house-pressure.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-cfm50.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-flue.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-infil-natural-ach.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-overhangs.osw +32 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-enclosure-windows-none.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-ambient.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-conditioned-basement-slab-insulation.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-slab.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement-assembly-r.osw +30 -54
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement-wall-insulation.osw +30 -54
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unconditioned-basement.osw +30 -54
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-unvented-crawlspace.osw +30 -54
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-foundation-vented-crawlspace.osw +30 -54
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed-cooling-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed-heating-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-1-speed.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-2-speed.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-air-to-air-heat-pump-var-speed.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-coal-only.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-elec-only.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-gas-central-ac-1-speed.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-gas-only.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-oil-only.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-propane-only.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-boiler-wood-only.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-1-speed.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-2-speed.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-only-var-speed.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-central-ac-plus-air-to-air-heat-pump-heating.osw +31 -57
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-electric.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-2-speed.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-air-to-air-heat-pump-var-speed.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-dual-fuel-mini-split-heat-pump-ducted.osw +32 -57
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ducts-leakage-percent.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-elec-resistance-only.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-furnace-gas.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-only-ducted.osw +32 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-evap-cooler-only.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-fireplace-wood-only.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-fixed-heater-gas-only.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-floor-furnace-propane-only.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-coal-only.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-elec-central-ac-1-speed.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-elec-only.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-central-ac-2-speed.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-central-ac-var-speed.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-only.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-gas-room-ac.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-oil-only.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-propane-only.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-furnace-wood-only.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump-cooling-only.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump-heating-only.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-ground-to-air-heat-pump.osw +31 -57
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-plug-loads-additional-multipliers.osw → base-hvac-install-quality-airflow-defect-furnace-gas-central-ac-1-speed.osw} +36 -58
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-1-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-2-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-air-to-air-heat-pump-var-speed.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-1-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-2-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-central-ac-var-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-furnace-gas-only.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-ground-to-air-heat-pump.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-mini-split-air-conditioner-only-ducted.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-all-mini-split-heat-pump-ducted.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-charge-defect-furnace-gas-central-ac-1-speed.osw +338 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-install-quality-none-furnace-gas-central-ac-1-speed.osw +340 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-air-conditioner-only-ducted.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-air-conditioner-only-ductless.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted-cooling-only.osw +32 -57
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted-heating-only.osw +32 -57
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ducted.osw +32 -57
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-mini-split-heat-pump-ductless.osw +32 -57
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-none.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-portable-heater-gas-only.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-programmable-thermostat-detailed.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-room-ac-only-33percent.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-room-ac-only.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-setpoints.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-stove-oil-only.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-stove-wood-pellets-only.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-undersized.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-hvac-wall-furnace-elec-only.osw +31 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-lighting-ceiling-fans.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-lighting-detailed.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-AMY-2012.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-baltimore-md.osw +40 -64
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-dallas-tx.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-duluth-mn.osw +44 -68
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-helena-mt.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-honolulu-hi.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-miami-fl.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-phoenix-az.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-location-portland-or.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-balanced.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-bath-kitchen-fans.osw +39 -65
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-cfis-evap-cooler-only-ducted.osw +32 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-cfis.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-erv-atre-asre.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-erv.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-exhaust-rated-flow-rate.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-exhaust.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-hrv-asre.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-hrv.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-supply.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-mechvent-whole-house-fan.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-defaults.osw +29 -53
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-loads-large-uncommon.osw +29 -53
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-loads-large-uncommon2.osw +29 -53
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-neighbor-shading.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-shielding-of-home.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-misc-usage-multiplier.osw +30 -54
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-pv.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-vacancy-6-months.osw → base-schedules-stochastic-vacant.osw} +34 -58
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-schedules-stochastic.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-schedules-user-specified.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-calendar-year-custom.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-daylight-saving-custom.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-daylight-saving-disabled.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-runperiod-1-month.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base-simcontrol-timestep-10-mins.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/base.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/build_residential_hpxml_test.rb +57 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-auto.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-double-exterior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-eaves.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-single-exterior-front.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-slab.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-unvented-crawlspace.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-left-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-middle-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-bottom-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-bottom.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-middle-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-middle.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-top-double-loaded-interior.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace-right-top.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-multifamily-vented-crawlspace.osw +341 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-atticroof-conditioned-eaves-gable.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-atticroof-conditioned-eaves-hip.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-double-exterior.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-double-loaded-interior.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-single-exterior-front.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-slab.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unconditioned-basement-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unconditioned-basement-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unconditioned-basement.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-unvented-crawlspace.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace-middle.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace-right.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-bldgtype-single-family-attached-vented-crawlspace.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-dhw-solar-latitude.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-atticroof-conditioned-eaves-gable.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-atticroof-conditioned-eaves-hip.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-garage-atticroof-conditioned.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-garage-partially-protruded.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-enclosure-windows-shading.osw +339 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-pv-roofpitch.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-schedules-random-seed.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-boiler-to-heat-pump.osw +336 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-boiler-to-heating-system.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-fireplace-to-heat-pump.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-second-heating-system-fireplace.osw → extra-second-heating-system-fireplace-to-heating-system.osw} +34 -58
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-heating-system-portable-heater-to-heat-pump.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{extra-second-heating-system-portable-heater.osw → extra-second-heating-system-portable-heater-to-heating-system.osw} +32 -56
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-second-refrigerator.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-clothes-washer-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-dishwasher-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-extra-refrigerator-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-freezer-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-zero-refrigerator-kwh.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-attic-with-floor-insulation.osw +34 -58
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-attic-with-one-floor-above-grade.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/conditioned-basement-with-ceiling-insulation.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/cooling-system-and-heat-pump.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/dhw-indirect-without-boiler.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/ducts-location-and-areas-not-same-type.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/foundation-wall-insulation-greater-than-height.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/heating-system-and-heat-pump.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-bottom-crawlspace-zero-foundation-height.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-bottom-slab-non-zero-foundation-height.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multifamily-no-building-orientation.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-fuel-loads.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-other-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/{multipliers-without-plug-loads.osw → multipliers-without-tv-plug-loads.osw} +35 -59
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-vehicle-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/multipliers-without-well-pump-plug-loads.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-electric-heat-pump-water-heater.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-integer-ceiling-fan-quantity.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/non-integer-geometry-num-bathrooms.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-but-no-primary-heating.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-serves-majority-heat.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/second-heating-system-serves-total-heat-load.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-attached-ambient.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-attached-no-building-orientation.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-detached-finished-basement-zero-foundation-height.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/single-family-detached-slab-non-zero-foundation-height.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/slab-non-zero-foundation-height-above-grade.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unconditioned-basement-with-wall-and-ceiling-insulation.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unvented-attic-with-floor-and-roof-insulation.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/unvented-crawlspace-with-wall-and-ceiling-insulation.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/vented-attic-with-floor-and-roof-insulation.osw +33 -57
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/vented-crawlspace-with-wall-and-ceiling-insulation.osw +31 -55
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/invalid_files/zero-number-of-bedrooms.osw +337 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/schedules/vacant.csv +8761 -0
- data/example_files/resources/hpxml-measures/Changelog.md +238 -0
- data/example_files/resources/hpxml-measures/Gemfile +4 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.rb +265 -838
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.xml +135 -114
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/BaseElements.xsd +5 -97
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/EPvalidator.xml +573 -193
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/HPXMLDataTypes.xsd +2 -28
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/HPXMLvalidator.xml +114 -22
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/airflow.rb +107 -176
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constants.rb +12 -180
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constructions.rb +481 -94
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/generator.rb +2 -6
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/geometry.rb +23 -11
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hotwater_appliances.rb +27 -25
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml.rb +735 -453
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_defaults.rb +417 -105
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac.rb +1377 -1335
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac_sizing.rb +1393 -1467
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/lighting.rb +2 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/location.rb +20 -7
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/meta_measure.rb +64 -3
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/misc_loads.rb +2 -22
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/pv.rb +1 -3
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedules.rb +15 -6
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/simcontrols.rb +7 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/unit_conversions.rb +2 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/version.rb +1 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/waterheater.rb +3 -4
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/xmlhelper.rb +31 -30
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_airflow.rb +4 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_constructions.rb +62 -16
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_defaults.rb +507 -628
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_generator.rb +3 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb +4 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac.rb +321 -6
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_lighting.rb +3 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_location.rb +3 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_miscloads.rb +3 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_pv.rb +3 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_simcontrols.rb +3 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_validation.rb +25 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_water_heater.rb +3 -0
- data/example_files/resources/hpxml-measures/README.md +4 -4
- data/example_files/resources/hpxml-measures/SimulationOutputReport/measure.rb +111 -37
- data/example_files/resources/hpxml-measures/SimulationOutputReport/measure.xml +318 -490
- data/example_files/resources/hpxml-measures/SimulationOutputReport/tests/output_report_test.rb +237 -183
- data/example_files/resources/hpxml-measures/docs/source/conf.py +4 -1
- data/example_files/resources/hpxml-measures/docs/source/getting_started.rst +2 -2
- data/example_files/resources/hpxml-measures/docs/source/intro.rst +3 -105
- data/example_files/resources/hpxml-measures/docs/source/workflow_inputs.rst +476 -351
- data/example_files/resources/hpxml-measures/docs/source/workflow_outputs.rst +154 -130
- data/example_files/resources/hpxml-measures/tasks.rb +1287 -511
- data/example_files/resources/hpxml-measures/weather/USA_AZ_Phoenix-Sky.Harbor.Intl.AP.722780_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_AZ_Phoenix-Sky.Harbor.Intl.AP.722780_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_HI_Honolulu.Intl.AP.911820_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_HI_Honolulu.Intl.AP.911820_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_MT_Helena.Rgnl.AP.727720_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_MT_Helena.Rgnl.AP.727720_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/weather/USA_OR_Portland.Intl.AP.726980_TMY3-cache.csv +35 -0
- data/example_files/resources/hpxml-measures/weather/USA_OR_Portland.Intl.AP.726980_TMY3.epw +8768 -0
- data/example_files/resources/hpxml-measures/workflow/run_simulation.rb +23 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-coal.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-50percent.xml +2 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-ief-portable.xml +2 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-ief-whole-home.xml +2 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-multiple.xml +534 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier.xml +2 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-gas.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-modified.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-none.xml +1 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-oil.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-propane.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-wood.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-cathedral.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-conditioned.xml +3 -3
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-flat.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-radiant-barrier.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-unvented-insulated-roof.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-vented.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-multifamily-buffer-space.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-multiple.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-non-freezing-space.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-other-heated-space.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-adjacent-to-other-housing-unit.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-baseboard.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-fan-coil-ducted.xml +4 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-fan-coil.xml +20 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-chiller-water-loop-heat-pump.xml +27 -18
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-cooling-tower-water-loop-heat-pump.xml +27 -18
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-baseboard.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil-ducted.xml +4 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil-eae.xml +20 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-fan-coil.xml +20 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-boiler-only-water-loop-heat-pump.xml +22 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-baseboard.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-fan-coil-ducted.xml +4 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-fan-coil.xml +20 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-chiller-only-water-loop-heat-pump.xml +22 -12
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-cooling-tower-only-water-loop-heat-pump.xml +22 -12
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-generator.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-ground-loop-ground-to-air-heat-pump.xml +2 -3
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-laundry-room.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent-multiple.xml +2 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent-preconditioning.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-mechvent.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-pv.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-water-heater-recirc.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily-shared-water-heater.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-multifamily.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-single-family-attached.xml +14 -2
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless-outside.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-2-speed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-gshp.xml +563 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-hpwh.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-tankless.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-var-speed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-dwhr.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-dse.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-outside.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-standbyloss.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-with-solar-fraction.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-electric.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-gas.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-hpwh.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-indirect.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-low-flow-fixtures.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-multiple.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-none.xml +1 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-demand.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-manual.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-nocontrol.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-temperature.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-timer.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-evacuated-tube.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-flat-plate.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-ics.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-fraction.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-indirect-flat-plate.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-thermosyphon-flat-plate.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-coal.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-elec-uef.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-outside.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-uef.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-outside.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-uef.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar-fraction.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-oil.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-wood.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-outside.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-uef.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-uef.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar-fraction.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-propane.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories-garage.xml +2 -2
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-1.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-2.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-4.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-5.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-garage.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-ach-house-pressure.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm-house-pressure.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm50.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-flue.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-natural-ach.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-overhangs.xml +6 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-rooftypes.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-shading.xml +600 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-level.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-surfaces.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-surfaces2.xml +2474 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-walltypes.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-none.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-enclosure-windows-interior-shading.xml → base-enclosure-windows-shading.xml} +576 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-ambient.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-basement-garage.xml +643 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-complex.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-slab-insulation.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-wall-interior-insulation.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-multiple.xml +3 -3
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-slab.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-above-grade.xml +2 -2
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-assembly-r.xml +2 -2
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-wall-insulation.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement.xml +2 -2
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unvented-crawlspace.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-vented-crawlspace.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-walkout-basement.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-cooling-only.xml +555 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-heating-only.xml +561 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-2-speed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-cooling-only.xml +552 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-heating-only.xml +557 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-1-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-air-to-air-heat-pump-1-speed-manual-s-oversize-allowances.xml} +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-1-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-1-speed.xml} +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-2-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-air-to-air-heat-pump-2-speed-manual-s-oversize-allowances.xml} +559 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-2-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-2-speed.xml} +556 -556
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-var-speed-autosize.xml → base-hvac-autosize-air-to-air-heat-pump-var-speed-manual-s-oversize-allowances.xml} +559 -556
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-air-to-air-heat-pump-var-speed-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-air-to-air-heat-pump-var-speed.xml} +556 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-elec-only-autosize.xml → base-hvac-autosize-boiler-elec-only.xml} +517 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-gas-central-ac-1-speed-autosize.xml → base-hvac-autosize-boiler-gas-central-ac-1-speed.xml} +568 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-boiler-gas-only-autosize.xml → base-hvac-autosize-boiler-gas-only.xml} +518 -519
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-1-speed-autosize.xml → base-hvac-autosize-central-ac-only-1-speed.xml} +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-2-speed-autosize.xml → base-hvac-autosize-central-ac-only-2-speed.xml} +546 -546
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-only-var-speed-autosize.xml → base-hvac-autosize-central-ac-only-var-speed.xml} +546 -546
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-central-ac-plus-air-to-air-heat-pump-heating-autosize.xml → base-hvac-autosize-central-ac-plus-air-to-air-heat-pump-heating.xml} +1 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-autosize.xml → base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed.xml} +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-dual-fuel-mini-split-heat-pump-ducted-autosize.xml → base-hvac-autosize-dual-fuel-mini-split-heat-pump-ducted.xml} +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-elec-resistance-only-autosize.xml → base-hvac-autosize-elec-resistance-only.xml} +508 -509
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-evap-cooler-furnace-gas-autosize.xml → base-hvac-autosize-evap-cooler-furnace-gas.xml} +552 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-floor-furnace-propane-only-autosize.xml → base-hvac-autosize-floor-furnace-propane-only.xml} +511 -512
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-elec-only-autosize.xml → base-hvac-autosize-furnace-elec-only.xml} +546 -546
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-central-ac-2-speed-autosize.xml → base-hvac-autosize-furnace-gas-central-ac-2-speed.xml} +559 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-central-ac-var-speed-autosize.xml → base-hvac-autosize-furnace-gas-central-ac-var-speed.xml} +559 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-gas-only.xml +547 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-room-ac-autosize.xml → base-hvac-autosize-furnace-gas-room-ac.xml} +557 -557
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-cooling-only.xml +554 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-heating-only.xml +559 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-ground-to-air-heat-pump-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-ground-to-air-heat-pump-manual-s-oversize-allowances.xml} +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-ground-to-air-heat-pump-autosize.xml → base-hvac-autosize-ground-to-air-heat-pump.xml} +558 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-air-conditioner-only-ducted.xml +546 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-cooling-only-autosize.xml → base-hvac-autosize-mini-split-heat-pump-ducted-cooling-only.xml} +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-heating-only-autosize.xml → base-hvac-autosize-mini-split-heat-pump-ducted-heating-only.xml} +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-autosize-manual-s-oversize-allowances.xml → base-hvac-autosize-mini-split-heat-pump-ducted-manual-s-oversize-allowances.xml} +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted.xml +556 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-room-ac-only-autosize.xml → base-hvac-autosize-room-ac-only.xml} +507 -508
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-stove-oil-only-autosize.xml → base-hvac-autosize-stove-oil-only.xml} +511 -512
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-wall-furnace-elec-only-autosize.xml → base-hvac-autosize-wall-furnace-elec-only.xml} +511 -512
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-autosize.xml → base-hvac-autosize.xml} +559 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-coal-only.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-elec-only.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-central-ac-1-speed.xml +1 -2
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-only.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-oil-only.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-propane-only.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-wood-only.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-1-speed.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-2-speed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-var-speed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-plus-air-to-air-heat-pump-heating.xml +1 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dse.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-electric.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-2-speed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-var-speed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-mini-split-heat-pump-ducted.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-leakage-percent.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-elec-resistance-only.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-furnace-gas.xml +2 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only-ducted.xml +10 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fireplace-wood-only.xml +512 -513
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fixed-heater-gas-only.xml +563 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-floor-furnace-propane-only.xml +512 -513
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-coal-only.xml +547 -547
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-central-ac-1-speed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-only.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-2-speed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-var-speed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only.xml +547 -550
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-room-ac.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-oil-only.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-propane-only.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-wood-only.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-x3-dse.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-cooling-only.xml +556 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-heating-only.xml +562 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump.xml +561 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/{invalid_files/slab-zero-exposed-perimeter.xml → base-hvac-install-quality-airflow-defect-furnace-gas-central-ac-1-speed.xml} +567 -561
- data/example_files/resources/hpxml-measures/workflow/sample_files/{invalid_files/heat-pump-mixed-fixed-and-autosize-capacities2.xml → base-hvac-install-quality-all-air-to-air-heat-pump-1-speed.xml} +565 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-air-to-air-heat-pump-2-speed.xml +566 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-air-to-air-heat-pump-var-speed.xml +566 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-misc-shelter-coefficient.xml → base-hvac-install-quality-all-furnace-gas-central-ac-1-speed.xml} +570 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-central-ac-2-speed.xml +571 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-furnace-gas-central-ac-var-speed.xml +571 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-furnace-gas-only-autosize.xml → base-hvac-install-quality-all-furnace-gas-only.xml} +551 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-all-ground-to-air-heat-pump.xml +565 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-air-conditioner-only-ducted-autosize.xml → base-hvac-install-quality-all-mini-split-air-conditioner-only-ducted.xml} +551 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/{hvac_autosizing/base-hvac-mini-split-heat-pump-ducted-autosize.xml → base-hvac-install-quality-all-mini-split-heat-pump-ducted.xml} +564 -558
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-blower-efficiency-furnace-gas-central-ac-1-speed.xml +568 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-charge-defect-furnace-gas-central-ac-1-speed.xml +565 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-none-furnace-gas-central-ac-1-speed.xml +569 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ducted.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ductless.xml +0 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-cooling-only.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-heating-only.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless.xml +0 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-multiple.xml +916 -913
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-multiple2.xml +837 -834
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-none.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-portable-heater-gas-only.xml +563 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-programmable-thermostat-detailed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-programmable-thermostat.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-33percent.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-oil-only.xml +512 -513
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-wood-pellets-only.xml +512 -513
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized-allow-increased-fixed-capacities.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-wall-furnace-elec-only.xml +512 -513
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-ceiling-fans.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-detailed.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-none.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-AMY-2012.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-baltimore-md.xml +34 -23
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-dallas-tx.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-duluth-mn.xml +34 -23
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-helena-mt.xml +562 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-honolulu-hi.xml +516 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-miami-fl.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-phoenix-az.xml +516 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-portland-or.xml +576 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-balanced.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-bath-kitchen-fans.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-dse.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-evap-cooler-only-ducted.xml +10 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv-atre-asre.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust-rated-flow-rate.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv-asre.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-multiple.xml +2 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-supply.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-whole-house-fan.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-defaults.xml +1 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon.xml +5 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon2.xml +9 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-none.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-neighbor-shading.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-shielding-of-home.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-usage-multiplier.xml +5 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-multiple-buildings.xml +1654 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-stochastic-vacant.xml +563 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-stochastic.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-user-specified.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-calendar-year-custom.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-custom.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-disabled.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-runperiod-1-month.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/base.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/boiler-invalid-afue.xml +519 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/cfis-with-hydronic-distribution.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/clothes-dryer-location.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/clothes-washer-location.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/cooking-range-location.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dehumidifier-fraction-served.xml +534 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dehumidifier-setpoints.xml +534 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dhw-frac-load-served.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dhw-invalid-ef-tank.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dhw-invalid-uef-tank-heat-pump.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/dishwasher-location.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-leakage-cfm25.xml +562 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-leakage-percent.xml +562 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-location-unconditioned-space.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duct-location.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/duplicate-id.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-attic-missing-roof.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-basement-missing-exterior-foundation-wall.xml +2 -2
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-basement-missing-slab.xml +2 -2
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-floor-area-exceeds-cfa.xml +4 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-floor-area-exceeds-cfa2.xml +447 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-exterior-wall.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-roof-ceiling.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-garage-missing-slab.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-ceiling-roof.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-exterior-wall.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/enclosure-living-missing-floor-slab.xml +11 -58
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-sensible-fuel-load.xml +759 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-sensible-plug-load.xml +758 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-total-fuel-load.xml +760 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/frac-total-plug-load.xml +758 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/furnace-invalid-afue.xml +562 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/generator-number-of-bedrooms-served.xml +459 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/generator-output-greater-than-consumption.xml +578 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/heat-pump-mixed-fixed-and-autosize-capacities.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-multiple-attached-cooling.xml +916 -913
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-multiple-attached-heating.xml +916 -913
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-distribution-return-duct-leakage-missing.xml +2 -7
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-dse-multiple-attached-cooling.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-dse-multiple-attached-heating.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-frac-load-served.xml +916 -913
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-inconsistent-fan-powers.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/hvac-invalid-distribution-system-type.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-assembly-effective-rvalue.xml +562 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-boolean.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-float.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-datatype-integer.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-daylight-saving.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-distribution-cfa-served.xml +2 -2
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-epw-filepath.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-facility-type-equipment.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-facility-type-surfaces.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-foundation-wall-properties.xml +573 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-id.xml +590 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-id2.xml +590 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-infiltration-volume.xml +562 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-input-parameters.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-neighbor-shading-azimuth.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-number-of-bedrooms-served.xml +464 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-number-of-conditioned-floors.xml +562 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-number-of-units-served.xml +450 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-relatedhvac-desuperheater.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-relatedhvac-dhw-indirect.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-runperiod.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-schema-version.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-shared-vent-in-unit-flowrate.xml +472 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-timestep.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/invalid-window-height.xml +6 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/lighting-fractions.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/missing-duct-location.xml +912 -909
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/missing-elements.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-appliance.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-duct.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-surface.xml +12 -2
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multifamily-reference-water-heater.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-buildings-without-building-id.xml +1654 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-buildings-wrong-building-id.xml +1654 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-ideal-air.xml → invalid_files/multiple-shared-cooling-systems.xml} +431 -498
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/multiple-shared-heating-systems.xml +434 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/net-area-negative-roof.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/net-area-negative-wall.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/num-bedrooms-exceeds-limit.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/orphaned-hvac-distribution.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerator-location.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerators-multiple-primary.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/refrigerators-no-primary.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/repeated-relatedhvac-desuperheater.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/repeated-relatedhvac-dhw-indirect.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-combi-tankless.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-desuperheater.xml +1 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/solar-thermal-system-with-dhw-indirect.xml +0 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-cfis.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-door.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-hvac-distribution.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-shared-clothes-washer-water-heater.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-shared-dishwasher-water-heater.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-skylight.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-solar-thermal-system.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/unattached-window.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/water-heater-location-other.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/sample_files/invalid_files/water-heater-location.xml +1 -1
- data/example_files/resources/hpxml-measures/workflow/template.osw +4 -1
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AL.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AL.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AL.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AL.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AL.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AL.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AL.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AL.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AL.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AL.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AL.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L302XC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L304XC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L322XC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L324XC.xml +0 -3
- data/example_files/resources/hpxml-measures/workflow/tests/hpxml_translator_test.rb +232 -360
- data/example_files/{measures/BuildResidentialModel/resources → resources}/measure-info.json +0 -0
- data/example_files/{measures/BuildResidentialModel/resources → resources}/meta_measure.rb +53 -44
- data/lib/uo_cli.rb +187 -44
- data/lib/uo_cli/version.rb +17 -7
- data/requirements.txt +2 -0
- data/uo_cli.gemspec +2 -2
- metadata +248 -64
- data/example_files/measures/ResidentialGeometryCreateMultifamily/measure.rb +0 -1005
- data/example_files/measures/ResidentialGeometryCreateMultifamily/measure.xml +0 -326
- data/example_files/measures/ResidentialGeometryCreateMultifamily/tests/create_residential_multifamily_geometry_test.rb +0 -477
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/measure.rb +0 -1039
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/measure.xml +0 -393
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyAttached/tests/create_residential_single_family_attached_geometry_test.rb +0 -456
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/measure.rb +0 -979
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/measure.xml +0 -388
- data/example_files/measures/ResidentialGeometryCreateSingleFamilyDetached/tests/create_residential_single_family_detached_geometry_test.rb +0 -704
- data/example_files/resources/hpxml-measures/.circleci/config.yml +0 -20
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/location.rb +0 -24
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/extra-hvac-programmable-thermostat.osw +0 -369
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>1539.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>12312.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>3078.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>24624.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -28,9 +28,6 @@
|
|
28
28
|
<NumberofBedrooms>3</NumberofBedrooms>
|
29
29
|
<ConditionedFloorArea>3078.0</ConditionedFloorArea>
|
30
30
|
<ConditionedBuildingVolume>24624.0</ConditionedBuildingVolume>
|
31
|
-
<extension>
|
32
|
-
<UseOnlyIdealAirSystem>true</UseOnlyIdealAirSystem>
|
33
|
-
</extension>
|
34
31
|
</BuildingConstruction>
|
35
32
|
</BuildingSummary>
|
36
33
|
<ClimateandRiskZones>
|
@@ -2,9 +2,9 @@
|
|
2
2
|
|
3
3
|
require_relative '../../HPXMLtoOpenStudio/resources/minitest_helper'
|
4
4
|
require 'openstudio'
|
5
|
-
require 'openstudio/measure/ShowRunnerOutput'
|
6
5
|
require 'minitest/autorun'
|
7
6
|
require 'fileutils'
|
7
|
+
require 'parallel'
|
8
8
|
require_relative '../../HPXMLtoOpenStudio/measure.rb'
|
9
9
|
require_relative '../../HPXMLtoOpenStudio/resources/constants'
|
10
10
|
require_relative '../../HPXMLtoOpenStudio/resources/meta_measure'
|
@@ -12,12 +12,8 @@ require_relative '../../HPXMLtoOpenStudio/resources/unit_conversions'
|
|
12
12
|
require_relative '../../HPXMLtoOpenStudio/resources/xmlhelper'
|
13
13
|
|
14
14
|
class HPXMLTest < MiniTest::Test
|
15
|
-
@@simulation_runtime_key = 'Simulation Runtime'
|
16
15
|
@@workflow_runtime_key = 'Workflow Runtime'
|
17
16
|
|
18
|
-
@@os_log = OpenStudio::StringStreamLogSink.new
|
19
|
-
@@os_log.setLogLevel(OpenStudio::Warn)
|
20
|
-
|
21
17
|
def before_setup
|
22
18
|
@this_dir = File.dirname(__FILE__)
|
23
19
|
@results_dir = File.join(@this_dir, 'results')
|
@@ -25,44 +21,37 @@ class HPXMLTest < MiniTest::Test
|
|
25
21
|
end
|
26
22
|
|
27
23
|
def test_simulations
|
28
|
-
sample_files_dir = File.absolute_path(File.join(@this_dir, '..', 'sample_files'))
|
29
|
-
autosize_dir = File.absolute_path(File.join(@this_dir, '..', 'sample_files', 'hvac_autosizing'))
|
30
|
-
|
31
24
|
results_out = File.join(@results_dir, 'results.csv')
|
32
25
|
File.delete(results_out) if File.exist? results_out
|
33
26
|
sizing_out = File.join(@results_dir, 'results_hvac_sizing.csv')
|
34
27
|
File.delete(sizing_out) if File.exist? sizing_out
|
35
28
|
|
36
|
-
test_dirs = [sample_files_dir,
|
37
|
-
autosize_dir]
|
38
|
-
|
39
29
|
xmls = []
|
40
|
-
|
41
|
-
|
42
|
-
|
43
|
-
end
|
30
|
+
sample_files_dir = File.absolute_path(File.join(@this_dir, '..', 'sample_files'))
|
31
|
+
Dir["#{sample_files_dir}/*.xml"].sort.each do |xml|
|
32
|
+
xmls << File.absolute_path(xml)
|
44
33
|
end
|
45
34
|
|
46
35
|
# Test simulations
|
47
36
|
puts "Running #{xmls.size} HPXML files..."
|
48
37
|
all_results = {}
|
49
38
|
all_sizing_results = {}
|
50
|
-
xmls.
|
51
|
-
|
39
|
+
Parallel.map(xmls, in_threads: Parallel.processor_count) do |xml|
|
40
|
+
xml_name = File.basename(xml)
|
41
|
+
all_results[xml_name], all_sizing_results[xml_name] = _run_xml(xml, Parallel.worker_number)
|
52
42
|
end
|
53
43
|
|
54
|
-
_write_summary_results(all_results, results_out)
|
55
|
-
_write_hvac_sizing_results(all_sizing_results, sizing_out)
|
44
|
+
_write_summary_results(all_results.sort_by { |k, v| k.downcase }.to_h, results_out)
|
45
|
+
_write_hvac_sizing_results(all_sizing_results.sort_by { |k, v| k.downcase }.to_h, sizing_out)
|
56
46
|
end
|
57
47
|
|
58
48
|
def test_ashrae_140
|
59
|
-
ashrae140_dir = File.absolute_path(File.join(@this_dir, 'ASHRAE_Standard_140'))
|
60
|
-
|
61
49
|
ashrae140_out = File.join(@results_dir, 'results_ashrae_140.csv')
|
62
50
|
File.delete(ashrae140_out) if File.exist? ashrae140_out
|
63
51
|
|
64
52
|
xmls = []
|
65
|
-
|
53
|
+
ashrae_140_dir = File.absolute_path(File.join(@this_dir, 'ASHRAE_Standard_140'))
|
54
|
+
Dir["#{ashrae_140_dir}/*.xml"].sort.each do |xml|
|
66
55
|
xmls << File.absolute_path(xml)
|
67
56
|
end
|
68
57
|
|
@@ -70,27 +59,28 @@ class HPXMLTest < MiniTest::Test
|
|
70
59
|
puts "Running #{xmls.size} HPXML files..."
|
71
60
|
all_results = {}
|
72
61
|
all_sizing_results = {}
|
73
|
-
xmls.
|
74
|
-
|
62
|
+
Parallel.map(xmls, in_threads: Parallel.processor_count) do |xml|
|
63
|
+
xml_name = File.basename(xml)
|
64
|
+
all_results[xml_name], all_sizing_results[xml_name] = _run_xml(xml, Parallel.worker_number)
|
75
65
|
end
|
76
66
|
|
77
|
-
_write_ashrae_140_results(all_results,
|
67
|
+
_write_ashrae_140_results(all_results.sort_by { |k, v| k.downcase }.to_h, ashrae140_out)
|
78
68
|
end
|
79
69
|
|
80
|
-
def
|
81
|
-
# Check that simulation
|
70
|
+
def test_run_simulation_json_output
|
71
|
+
# Check that the simulation produces JSON outputs (instead of CSV outputs) if requested
|
82
72
|
os_cli = OpenStudio.getOpenStudioCLI
|
83
73
|
rb_path = File.join(File.dirname(__FILE__), '..', 'run_simulation.rb')
|
84
74
|
xml = File.join(File.dirname(__FILE__), '..', 'sample_files', 'base.xml')
|
85
|
-
command = "#{os_cli} #{rb_path} -x #{xml} --debug --hourly ALL"
|
75
|
+
command = "#{os_cli} #{rb_path} -x #{xml} --debug --hourly ALL --output-format json"
|
86
76
|
system(command, err: File::NULL)
|
87
77
|
|
88
78
|
# Check for output files
|
89
79
|
sql_path = File.join(File.dirname(xml), 'run', 'eplusout.sql')
|
90
80
|
assert(File.exist? sql_path)
|
91
|
-
csv_output_path = File.join(File.dirname(xml), 'run', 'results_annual.
|
81
|
+
csv_output_path = File.join(File.dirname(xml), 'run', 'results_annual.json')
|
92
82
|
assert(File.exist? csv_output_path)
|
93
|
-
csv_output_path = File.join(File.dirname(xml), 'run', 'results_timeseries.
|
83
|
+
csv_output_path = File.join(File.dirname(xml), 'run', 'results_timeseries.json')
|
94
84
|
assert(File.exist? csv_output_path)
|
95
85
|
|
96
86
|
# Check for debug files
|
@@ -154,29 +144,42 @@ class HPXMLTest < MiniTest::Test
|
|
154
144
|
def test_invalid
|
155
145
|
sample_files_dir = File.join(@this_dir, '..', 'sample_files')
|
156
146
|
|
157
|
-
expected_error_msgs = { '
|
158
|
-
'
|
159
|
-
'clothes-
|
160
|
-
'
|
161
|
-
'
|
147
|
+
expected_error_msgs = { 'boiler-invalid-afue.xml' => ['Expected AnnualHeatingEfficiency[Units="AFUE"]/Value to be less than or equal to 1'],
|
148
|
+
'cfis-with-hydronic-distribution.xml' => ["Attached HVAC distribution system 'HVACDistribution' cannot be hydronic for ventilation fan 'MechanicalVentilation'."],
|
149
|
+
'clothes-dryer-location.xml' => ['A location is specified as "garage" but no surfaces were found adjacent to this space type.'],
|
150
|
+
'clothes-washer-location.xml' => ['A location is specified as "garage" but no surfaces were found adjacent to this space type.'],
|
151
|
+
'cooking-range-location.xml' => ['A location is specified as "garage" but no surfaces were found adjacent to this space type.'],
|
152
|
+
'dehumidifier-fraction-served.xml' => ['Expected FractionDehumidificationLoadServed to sum to <= 1, but calculated sum is 1.1.'],
|
153
|
+
'dehumidifier-setpoints.xml' => ['All dehumidifiers must have the same setpoint but multiple setpoints were specified.'],
|
154
|
+
'dishwasher-location.xml' => ['A location is specified as "garage" but no surfaces were found adjacent to this space type.'],
|
162
155
|
'dhw-frac-load-served.xml' => ['Expected FractionDHWLoadServed to sum to 1, but calculated sum is 1.15.'],
|
163
156
|
'dhw-invalid-ef-tank.xml' => ['Expected EnergyFactor to be less than 1 [context: /HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem[WaterHeaterType="storage water heater"]]'],
|
164
157
|
'dhw-invalid-uef-tank-heat-pump.xml' => ['Expected UniformEnergyFactor to be greater than 1 [context: /HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem[WaterHeaterType="heat pump water heater"]]'],
|
165
|
-
'duct-
|
166
|
-
'duct-
|
158
|
+
'duct-leakage-cfm25.xml' => ['Expected Value to be greater than or equal to 0 [context: /HPXML/Building/BuildingDetails/Systems/HVAC/HVACDistribution/DistributionSystemType/AirDistribution/DuctLeakageMeasurement/DuctLeakage[Units="CFM25"]]'],
|
159
|
+
'duct-leakage-percent.xml' => ['Expected Value to be less than 1 [context: /HPXML/Building/BuildingDetails/Systems/HVAC/HVACDistribution/DistributionSystemType/AirDistribution/DuctLeakageMeasurement/DuctLeakage[Units="Percent"]]'],
|
160
|
+
'duct-location.xml' => ['A location is specified as "garage" but no surfaces were found adjacent to this space type.'],
|
161
|
+
'duct-location-unconditioned-space.xml' => ["Expected DuctLocation to be 'living space' or 'basement - conditioned' or 'basement - unconditioned' or 'crawlspace - vented' or 'crawlspace - unvented' or 'attic - vented' or 'attic - unvented' or 'garage' or 'exterior wall' or 'under slab' or 'roof deck' or 'outside' or 'other housing unit' or 'other heated space' or 'other multifamily buffer space' or 'other non-freezing space' [context: /HPXML/Building/BuildingDetails/Systems/HVAC/HVACDistribution/DistributionSystemType/*/Ducts]"],
|
167
162
|
'duplicate-id.xml' => ["Duplicate SystemIdentifier IDs detected for 'WindowNorth'."],
|
168
|
-
'enclosure-attic-missing-roof.xml' => ['There must be at least one roof adjacent to attic - unvented.'],
|
169
|
-
'enclosure-basement-missing-exterior-foundation-wall.xml' => ['There must be at least one exterior foundation wall adjacent to basement - unconditioned.'],
|
170
|
-
'enclosure-basement-missing-slab.xml' => ['There must be at least one slab adjacent to basement - unconditioned.'],
|
171
|
-
'enclosure-floor-area-exceeds-cfa.xml' => ['
|
172
|
-
'enclosure-
|
173
|
-
'enclosure-garage-missing-
|
174
|
-
'enclosure-garage-missing-
|
175
|
-
'enclosure-
|
176
|
-
'enclosure-living-missing-
|
177
|
-
|
178
|
-
'
|
179
|
-
'
|
163
|
+
'enclosure-attic-missing-roof.xml' => ['There must be at least one roof adjacent to "attic - unvented". [context: /HPXML/Building/BuildingDetails/Enclosure[*/*[InteriorAdjacentTo="attic - unvented" or ExteriorAdjacentTo="attic - unvented"]]]'],
|
164
|
+
'enclosure-basement-missing-exterior-foundation-wall.xml' => ['There must be at least one exterior foundation wall adjacent to "basement - unconditioned". [context: /HPXML/Building/BuildingDetails/Enclosure[*/*[InteriorAdjacentTo="basement - unconditioned" or ExteriorAdjacentTo="basement - unconditioned"]]]'],
|
165
|
+
'enclosure-basement-missing-slab.xml' => ['There must be at least one slab adjacent to "basement - unconditioned". [context: /HPXML/Building/BuildingDetails/Enclosure[*/*[InteriorAdjacentTo="basement - unconditioned" or ExteriorAdjacentTo="basement - unconditioned"]]]'],
|
166
|
+
'enclosure-floor-area-exceeds-cfa.xml' => ['Expected ConditionedFloorArea to be greater than or equal to the sum of conditioned slab/floor areas. [context: /HPXML/Building/BuildingDetails/BuildingSummary/BuildingConstruction]'],
|
167
|
+
'enclosure-floor-area-exceeds-cfa2.xml' => ['Expected ConditionedFloorArea to be greater than or equal to the sum of conditioned slab/floor areas. [context: /HPXML/Building/BuildingDetails/BuildingSummary/BuildingConstruction]'],
|
168
|
+
'enclosure-garage-missing-exterior-wall.xml' => ['There must be at least one exterior wall/foundation wall adjacent to "garage". [context: /HPXML/Building/BuildingDetails/Enclosure[*/*[InteriorAdjacentTo="garage" or ExteriorAdjacentTo="garage"]]]'],
|
169
|
+
'enclosure-garage-missing-roof-ceiling.xml' => ['There must be at least one roof/ceiling adjacent to "garage". [context: /HPXML/Building/BuildingDetails/Enclosure[*/*[InteriorAdjacentTo="garage" or ExteriorAdjacentTo="garage"]]]'],
|
170
|
+
'enclosure-garage-missing-slab.xml' => ['There must be at least one slab adjacent to "garage". [context: /HPXML/Building/BuildingDetails/Enclosure[*/*[InteriorAdjacentTo="garage" or ExteriorAdjacentTo="garage"]]]'],
|
171
|
+
'enclosure-living-missing-ceiling-roof.xml' => ['There must be at least one ceiling/roof adjacent to conditioned space. [context: /HPXML/Building/BuildingDetails/Enclosure[*/*[InteriorAdjacentTo="living space"]]]',
|
172
|
+
'There must be at least one floor adjacent to "attic - unvented". [context: /HPXML/Building/BuildingDetails/Enclosure[*/*[InteriorAdjacentTo="attic - unvented" or ExteriorAdjacentTo="attic - unvented"]]]'],
|
173
|
+
'enclosure-living-missing-exterior-wall.xml' => ['There must be at least one exterior wall adjacent to conditioned space. [context: /HPXML/Building/BuildingDetails/Enclosure[*/*[InteriorAdjacentTo="living space"]]]'],
|
174
|
+
'enclosure-living-missing-floor-slab.xml' => ['There must be at least one floor/slab adjacent to conditioned space. [context: /HPXML/Building/BuildingDetails/Enclosure[*/*[InteriorAdjacentTo="living space"]]]'],
|
175
|
+
'frac-sensible-plug-load.xml' => ['Expected extension/FracSensible to be greater than or equal to 0 [context: /HPXML/Building/BuildingDetails/MiscLoads/PlugLoad[PlugLoadType="other" or PlugLoadType="TV other" or PlugLoadType="electric vehicle charging" or PlugLoadType="well pump"]]'],
|
176
|
+
'frac-total-plug-load.xml' => ['Expected sum of extension/FracSensible and extension/FracLatent to be less than or equal to 1 [context: /HPXML/Building/BuildingDetails/MiscLoads/PlugLoad[PlugLoadType="other" or PlugLoadType="TV other" or PlugLoadType="electric vehicle charging" or PlugLoadType="well pump"]]'],
|
177
|
+
'frac-sensible-fuel-load.xml' => ['Expected extension/FracSensible to be greater than or equal to 0 [context: /HPXML/Building/BuildingDetails/MiscLoads/FuelLoad[FuelLoadType="grill" or FuelLoadType="lighting" or FuelLoadType="fireplace"]]'],
|
178
|
+
'frac-total-fuel-load.xml' => ['Expected sum of extension/FracSensible and extension/FracLatent to be less than or equal to 1 [context: /HPXML/Building/BuildingDetails/MiscLoads/FuelLoad[FuelLoadType="grill" or FuelLoadType="lighting" or FuelLoadType="fireplace"]]'],
|
179
|
+
'furnace-invalid-afue.xml' => ['Expected AnnualHeatingEfficiency[Units="AFUE"]/Value to be less than or equal to 1'],
|
180
|
+
'generator-output-greater-than-consumption.xml' => ['Expected AnnualConsumptionkBtu to be greater than AnnualOutputkWh*3412 [context: /HPXML/Building/BuildingDetails/Systems/extension/Generators/Generator]'],
|
181
|
+
'generator-number-of-bedrooms-served.xml' => ['Expected NumberofBedroomsServed to be greater than ../../../../BuildingSummary/BuildingConstruction/NumberofBedrooms [context: /HPXML/Building/BuildingDetails/Systems/extension/Generators/Generator[IsSharedSystem="true"]]'],
|
182
|
+
'heat-pump-mixed-fixed-and-autosize-capacities.xml' => ['Expected 0 or 2 element(s) for xpath: HeatingCapacity | BackupHeatingCapacity [context: /HPXML/Building/BuildingDetails/Systems/HVAC/HVACPlant/HeatPump[BackupSystemFuel]]'],
|
180
183
|
'hvac-invalid-distribution-system-type.xml' => ["Incorrect HVAC distribution system type for HVAC type: 'Furnace'. Should be one of: ["],
|
181
184
|
'hvac-distribution-multiple-attached-cooling.xml' => ["Multiple cooling systems found attached to distribution system 'HVACDistribution2'."],
|
182
185
|
'hvac-distribution-multiple-attached-heating.xml' => ["Multiple heating systems found attached to distribution system 'HVACDistribution'."],
|
@@ -184,14 +187,12 @@ class HPXMLTest < MiniTest::Test
|
|
184
187
|
'hvac-dse-multiple-attached-heating.xml' => ["Multiple heating systems found attached to distribution system 'HVACDistribution'."],
|
185
188
|
'hvac-frac-load-served.xml' => ['Expected FractionCoolLoadServed to sum to <= 1, but calculated sum is 1.2.',
|
186
189
|
'Expected FractionHeatLoadServed to sum to <= 1, but calculated sum is 1.1.'],
|
187
|
-
'hvac-distribution-return-duct-leakage-missing.xml' => [
|
188
|
-
'hvac-inconsistent-fan-powers.xml' => ["Fan powers for heating system 'HeatingSystem' and cooling system 'CoolingSystem' must be the same."],
|
189
|
-
'invalid-
|
190
|
-
'invalid-datatype-
|
191
|
-
'invalid-datatype-integer.xml' => ["Cannot convert '2.5' to integer."],
|
192
|
-
'invalid-datatype-
|
193
|
-
'invalid-datatype-float.xml' => ["Cannot convert 'FOOBAR' to float."],
|
194
|
-
'invalid-datatype-float2.xml' => ["Cannot convert '' to float."],
|
190
|
+
'hvac-distribution-return-duct-leakage-missing.xml' => ['Expected 1 element(s) for xpath: DuctLeakageMeasurement[DuctType="return"]/DuctLeakage[(Units="CFM25" or Units="Percent") and TotalOrToOutside="to outside"] [context: /HPXML/Building/BuildingDetails/Systems/HVAC/HVACDistribution/DistributionSystemType/AirDistribution]'],
|
191
|
+
'hvac-inconsistent-fan-powers.xml' => ["Fan powers for heating system 'HeatingSystem' and cooling system 'CoolingSystem' are attached to a single distribution system and therefore must be the same."],
|
192
|
+
'invalid-assembly-effective-rvalue.xml' => ['Expected Insulation/AssemblyEffectiveRValue to be greater than 0 [context: /HPXML/Building/BuildingDetails/Enclosure/Walls/Wall]'],
|
193
|
+
'invalid-datatype-boolean.xml' => ["Cannot convert 'FOOBAR' to boolean for Roof/RadiantBarrier."],
|
194
|
+
'invalid-datatype-integer.xml' => ["Cannot convert '2.5' to integer for BuildingConstruction/NumberofBedrooms."],
|
195
|
+
'invalid-datatype-float.xml' => ["Cannot convert 'FOOBAR' to float for Slab/extension/CarpetFraction."],
|
195
196
|
'invalid-daylight-saving.xml' => ['Daylight Saving End Day of Month (31) must be one of: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30.'],
|
196
197
|
'invalid-distribution-cfa-served.xml' => ['The total conditioned floor area served by the HVAC distribution system(s) for heating is larger than the conditioned floor area of the building.',
|
197
198
|
'The total conditioned floor area served by the HVAC distribution system(s) for cooling is larger than the conditioned floor area of the building.'],
|
@@ -205,6 +206,12 @@ class HPXMLTest < MiniTest::Test
|
|
205
206
|
"The building is of type 'single-family detached' but the surface 'FoundationWallOther' is adjacent to Attached/Multifamily space 'other housing unit'.",
|
206
207
|
"The building is of type 'single-family detached' but the surface 'FloorOther' is adjacent to Attached/Multifamily space 'other housing unit'.",
|
207
208
|
"The building is of type 'single-family detached' but the surface 'CeilingOther' is adjacent to Attached/Multifamily space 'other housing unit'."],
|
209
|
+
'invalid-foundation-wall-properties.xml' => ['Expected DepthBelowGrade to be less than or equal to Height [context: /HPXML/Building/BuildingDetails/Enclosure/FoundationWalls/FoundationWall]',
|
210
|
+
'Expected extension/DistanceToBottomOfInsulation to be greater than or equal to extension/DistanceToTopOfInsulation [context: /HPXML/Building/BuildingDetails/Enclosure/FoundationWalls/FoundationWall/Insulation/Layer[InstallationType="continuous - exterior" or InstallationType="continuous - interior"]]',
|
211
|
+
'Expected extension/DistanceToBottomOfInsulation to be less than or equal to ../../Height [context: /HPXML/Building/BuildingDetails/Enclosure/FoundationWalls/FoundationWall/Insulation/Layer[InstallationType="continuous - exterior" or InstallationType="continuous - interior"]]'],
|
212
|
+
'invalid-id.xml' => ["Empty SystemIdentifier ID ('') detected for skylights."],
|
213
|
+
'invalid-id2.xml' => ['Expected id attribute for SystemIdentifier [context: /HPXML/Building/BuildingDetails/Enclosure/Skylights/Skylight]'],
|
214
|
+
'invalid-infiltration-volume.xml' => ['Expected InfiltrationVolume to be greater than or equal to ../../../BuildingSummary/BuildingConstruction/ConditionedBuildingVolume [context: /HPXML/Building/BuildingDetails/Enclosure/AirInfiltration/AirInfiltrationMeasurement[BuildingAirLeakage/UnitofMeasure[text()="ACH" or text()="CFM"]]]'],
|
208
215
|
'invalid-input-parameters.xml' => ["Expected Transaction to be 'create' or 'update' [context: /HPXML/XMLTransactionHeaderInformation]",
|
209
216
|
"Expected SiteType to be 'rural' or 'suburban' or 'urban' [context: /HPXML/Building/BuildingDetails/BuildingSummary/Site]",
|
210
217
|
"Expected Year to be '2012' or '2009' or '2006' or '2003' [context: /HPXML/Building/BuildingDetails/ClimateandRiskZones/ClimateZoneIECC]",
|
@@ -212,30 +219,38 @@ class HPXMLTest < MiniTest::Test
|
|
212
219
|
'Expected RadiantBarrierGrade to be less than or equal to 3 [context: /HPXML/Building/BuildingDetails/Enclosure/Roofs/Roof]',
|
213
220
|
'Expected EnergyFactor to be less than or equal to 5 [context: /HPXML/Building/BuildingDetails/Appliances/Dishwasher]'],
|
214
221
|
'invalid-neighbor-shading-azimuth.xml' => ['A neighbor building has an azimuth (145) not equal to the azimuth of any wall.'],
|
222
|
+
'invalid-number-of-bedrooms-served.xml' => ['Expected extension/NumberofBedroomsServed to be greater than ../../../BuildingSummary/BuildingConstruction/NumberofBedrooms [context: /HPXML/Building/BuildingDetails/Systems/Photovoltaics/PVSystem[IsSharedSystem="true"]]'],
|
223
|
+
'invalid-number-of-conditioned-floors.xml' => ['Expected NumberofConditionedFloors to be greater than or equal to NumberofConditionedFloorsAboveGrade [context: /HPXML/Building/BuildingDetails/BuildingSummary/BuildingConstruction]'],
|
224
|
+
'invalid-number-of-units-served.xml' => ['Expected NumberofUnitsServed to be greater than 1 [context: /HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem[IsSharedSystem="true"]]'],
|
215
225
|
'invalid-relatedhvac-dhw-indirect.xml' => ["RelatedHVACSystem 'HeatingSystem_bad' not found for water heating system 'WaterHeater'"],
|
216
226
|
'invalid-relatedhvac-desuperheater.xml' => ["RelatedHVACSystem 'CoolingSystem_bad' not found for water heating system 'WaterHeater'."],
|
217
227
|
'invalid-schema-version.xml' => ['HPXML version 3.0 is required.'],
|
228
|
+
'invalid-shared-vent-in-unit-flowrate.xml' => ['Expected extension/InUnitFlowRate to be less than RatedFlowRate [context: /HPXML/Building/BuildingDetails/Systems/MechanicalVentilation/VentilationFans/VentilationFan[UsedForWholeBuildingVentilation="true" and IsSharedSystem="true"]]'],
|
218
229
|
'invalid-timestep.xml' => ['Timestep (45) must be one of: 60, 30, 20, 15, 12, 10, 6, 5, 4, 3, 2, 1.'],
|
219
230
|
'invalid-runperiod.xml' => ['Run Period End Day of Month (31) must be one of: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30.'],
|
220
|
-
'invalid-window-height.xml' => [
|
231
|
+
'invalid-window-height.xml' => ['Expected DistanceToBottomOfWindow to be greater than DistanceToTopOfWindow [context: /HPXML/Building/BuildingDetails/Enclosure/Windows/Window/Overhangs]'],
|
221
232
|
'lighting-fractions.xml' => ['Sum of fractions of interior lighting (1.15) is greater than 1.'],
|
222
|
-
'mismatched-slab-and-foundation-wall.xml' => ["Foundation wall 'FoundationWall' is adjacent to 'basement - conditioned' but no corresponding slab was found adjacent to"],
|
223
233
|
'missing-elements.xml' => ['Expected 1 element(s) for xpath: NumberofConditionedFloors [context: /HPXML/Building/BuildingDetails/BuildingSummary/BuildingConstruction]',
|
224
234
|
'Expected 1 element(s) for xpath: ConditionedFloorArea [context: /HPXML/Building/BuildingDetails/BuildingSummary/BuildingConstruction]'],
|
225
|
-
'missing-duct-location.xml' => ['Expected 0 or 2 element(s) for xpath: DuctSurfaceArea | DuctLocation [context: /HPXML/Building/BuildingDetails/Systems/HVAC/HVACDistribution/DistributionSystemType/*/Ducts
|
226
|
-
'missing-duct-location-and-surface-area.xml' => ['Error: The location and surface area of all ducts must be provided or blank.'],
|
235
|
+
'missing-duct-location.xml' => ['Expected 0 or 2 element(s) for xpath: DuctSurfaceArea | DuctLocation [context: /HPXML/Building/BuildingDetails/Systems/HVAC/HVACDistribution/DistributionSystemType/*/Ducts]'],
|
227
236
|
'multifamily-reference-appliance.xml' => ["The building is of type 'single-family detached' but"],
|
228
237
|
'multifamily-reference-duct.xml' => ["The building is of type 'single-family detached' but"],
|
229
238
|
'multifamily-reference-surface.xml' => ["The building is of type 'single-family detached' but"],
|
230
239
|
'multifamily-reference-water-heater.xml' => ["The building is of type 'single-family detached' but"],
|
240
|
+
'multiple-buildings-without-building-id.xml' => ['Multiple Building elements defined in HPXML file; Building ID argument must be provided.'],
|
241
|
+
'multiple-buildings-wrong-building-id.xml' => ["Could not find Building element with ID 'MyFoo'."],
|
242
|
+
'multiple-shared-cooling-systems.xml' => ['More than one shared cooling system found.'],
|
243
|
+
'multiple-shared-heating-systems.xml' => ['More than one shared heating system found.'],
|
231
244
|
'net-area-negative-wall.xml' => ["Calculated a negative net surface area for surface 'Wall'."],
|
232
245
|
'net-area-negative-roof.xml' => ["Calculated a negative net surface area for surface 'Roof'."],
|
233
|
-
'num-bedrooms-exceeds-limit.xml' => ['
|
246
|
+
'num-bedrooms-exceeds-limit.xml' => ['Expected NumberofBedrooms to be less than or equal to (ConditionedFloorArea-120)/70 [context: /HPXML/Building/BuildingDetails/BuildingSummary/BuildingConstruction]'],
|
234
247
|
'orphaned-hvac-distribution.xml' => ["Distribution system 'HVACDistribution' found but no HVAC system attached to it."],
|
235
|
-
'refrigerator-location.xml' => [
|
248
|
+
'refrigerator-location.xml' => ['A location is specified as "garage" but no surfaces were found adjacent to this space type.'],
|
249
|
+
'refrigerators-multiple-primary.xml' => ['More than one refrigerator designated as the primary.'],
|
250
|
+
'refrigerators-no-primary.xml' => ['Could not find a primary refrigerator.'],
|
236
251
|
'repeated-relatedhvac-dhw-indirect.xml' => ["RelatedHVACSystem 'HeatingSystem' is attached to multiple water heating systems."],
|
237
252
|
'repeated-relatedhvac-desuperheater.xml' => ["RelatedHVACSystem 'CoolingSystem' is attached to multiple water heating systems."],
|
238
|
-
'slab-zero-exposed-perimeter.xml' => [
|
253
|
+
'slab-zero-exposed-perimeter.xml' => ['Expected ExposedPerimeter to be greater than 0 [context: /HPXML/Building/BuildingDetails/Enclosure/Slabs/Slab]'],
|
239
254
|
'solar-thermal-system-with-combi-tankless.xml' => ["Water heating system 'WaterHeater' connected to solar thermal system 'SolarThermalSystem' cannot be a space-heating boiler."],
|
240
255
|
'solar-thermal-system-with-desuperheater.xml' => ["Water heating system 'WaterHeater' connected to solar thermal system 'SolarThermalSystem' cannot be attached to a desuperheater."],
|
241
256
|
'solar-thermal-system-with-dhw-indirect.xml' => ["Water heating system 'WaterHeater' connected to solar thermal system 'SolarThermalSystem' cannot be a space-heating boiler."],
|
@@ -247,14 +262,13 @@ class HPXMLTest < MiniTest::Test
|
|
247
262
|
'unattached-shared-clothes-washer-water-heater.xml' => ["Attached water heating system 'foobar' not found for clothes washer"],
|
248
263
|
'unattached-shared-dishwasher-water-heater.xml' => ["Attached water heating system 'foobar' not found for dishwasher"],
|
249
264
|
'unattached-window.xml' => ["Attached wall 'foobar' not found for window 'WindowNorth'."],
|
250
|
-
'water-heater-location.xml' => [
|
251
|
-
'water-heater-location-other.xml' => ["Expected Location to be 'living space' or 'basement - unconditioned' or 'basement - conditioned' or 'attic - unvented' or 'attic - vented' or 'garage' or 'crawlspace - unvented' or 'crawlspace - vented' or 'other exterior' or 'other housing unit' or 'other heated space' or 'other multifamily buffer space' or 'other non-freezing space' [context: /HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem]"]
|
252
|
-
'refrigerators-multiple-primary.xml' => ['More than one refrigerator designated as the primary.'],
|
253
|
-
'refrigerators-no-primary.xml' => ['Could not find a primary refrigerator.'] }
|
265
|
+
'water-heater-location.xml' => ['A location is specified as "crawlspace - vented" but no surfaces were found adjacent to this space type.'],
|
266
|
+
'water-heater-location-other.xml' => ["Expected Location to be 'living space' or 'basement - unconditioned' or 'basement - conditioned' or 'attic - unvented' or 'attic - vented' or 'garage' or 'crawlspace - unvented' or 'crawlspace - vented' or 'other exterior' or 'other housing unit' or 'other heated space' or 'other multifamily buffer space' or 'other non-freezing space' [context: /HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem]"] }
|
254
267
|
|
255
268
|
# Test simulations
|
256
|
-
Dir["#{sample_files_dir}/invalid_files/*.xml"].sort
|
257
|
-
|
269
|
+
xmls = Dir["#{sample_files_dir}/invalid_files/*.xml"].sort
|
270
|
+
Parallel.map(xmls, in_threads: Parallel.processor_count) do |xml|
|
271
|
+
_run_xml(File.absolute_path(xml), Parallel.worker_number, true, expected_error_msgs[File.basename(xml)])
|
258
272
|
end
|
259
273
|
end
|
260
274
|
|
@@ -277,58 +291,25 @@ class HPXMLTest < MiniTest::Test
|
|
277
291
|
end
|
278
292
|
end
|
279
293
|
|
280
|
-
def _run_xml(xml, expect_error = false, expect_error_msgs = nil)
|
294
|
+
def _run_xml(xml, worker_num = nil, expect_error = false, expect_error_msgs = nil)
|
281
295
|
print "Testing #{File.basename(xml)}...\n"
|
282
|
-
rundir = File.join(@this_dir,
|
283
|
-
|
284
|
-
measures_dir = File.join(@this_dir, '..', '..')
|
285
|
-
|
286
|
-
measures = {}
|
296
|
+
rundir = File.join(@this_dir, "test#{worker_num}")
|
287
297
|
|
288
|
-
# Add HPXML translator measure to workflow
|
289
|
-
measure_subdir = 'HPXMLtoOpenStudio'
|
290
|
-
args = {}
|
291
|
-
args['hpxml_path'] = xml
|
292
|
-
args['output_dir'] = File.absolute_path(rundir)
|
293
|
-
args['debug'] = true
|
294
|
-
update_args_hash(measures, measure_subdir, args)
|
295
|
-
|
296
|
-
# Add reporting measure to workflow
|
297
298
|
# Uses 'monthly' to verify timeseries results match annual results via error-checking
|
298
299
|
# inside the SimulationOutputReport measure.
|
299
|
-
|
300
|
-
|
301
|
-
|
302
|
-
|
303
|
-
|
304
|
-
|
305
|
-
|
306
|
-
|
307
|
-
args['include_timeseries_zone_temperatures'] = true
|
308
|
-
args['include_timeseries_airflows'] = true
|
309
|
-
args['include_timeseries_weather'] = true
|
310
|
-
update_args_hash(measures, measure_subdir, args)
|
311
|
-
|
312
|
-
# Add output variables for combi system energy check and CFIS
|
313
|
-
output_vars = [['Water Heater Source Side Heat Transfer Energy', 'runperiod', '*'],
|
314
|
-
['Baseboard Total Heating Energy', 'runperiod', '*'],
|
315
|
-
['Boiler Heating Energy', 'runperiod', '*'],
|
316
|
-
['Fluid Heat Exchanger Heat Transfer Energy', 'runperiod', '*'],
|
317
|
-
['Fan Electricity Rate', 'runperiod', '*'],
|
318
|
-
['Fan Runtime Fraction', 'runperiod', '*'],
|
319
|
-
['Electric Equipment Electricity Energy', 'runperiod', Constants.ObjectNameMechanicalVentilationHouseFanCFIS]]
|
320
|
-
|
321
|
-
# Run workflow
|
300
|
+
cli_path = OpenStudio.getOpenStudioCLI
|
301
|
+
building_id = ''
|
302
|
+
if xml.include? 'base-multiple-buildings.xml'
|
303
|
+
building_id = '--building-id MyBuilding'
|
304
|
+
elsif xml.include? 'multiple-buildings-wrong-building-id.xml'
|
305
|
+
building_id = '--building-id MyFoo'
|
306
|
+
end
|
307
|
+
command = "\"#{cli_path}\" \"#{File.join(File.dirname(__FILE__), '../run_simulation.rb')}\" -x #{xml} -o #{rundir} --debug --monthly ALL #{building_id}"
|
322
308
|
workflow_start = Time.now
|
323
|
-
|
324
|
-
|
325
|
-
|
326
|
-
|
327
|
-
success = results[:success]
|
328
|
-
runner = results[:runner]
|
329
|
-
sim_time = results[:sim_time]
|
330
|
-
puts "Completed in #{workflow_time} seconds."
|
331
|
-
puts
|
309
|
+
success = system(command)
|
310
|
+
workflow_time = Time.now - workflow_start
|
311
|
+
|
312
|
+
rundir = File.join(rundir, 'run')
|
332
313
|
|
333
314
|
# Check results
|
334
315
|
if expect_error
|
@@ -357,7 +338,6 @@ class HPXMLTest < MiniTest::Test
|
|
357
338
|
return
|
358
339
|
end
|
359
340
|
|
360
|
-
show_output(runner.result) unless success
|
361
341
|
assert_equal(true, success)
|
362
342
|
|
363
343
|
# Check for output files
|
@@ -367,16 +347,26 @@ class HPXMLTest < MiniTest::Test
|
|
367
347
|
assert(File.exist? timeseries_csv_path)
|
368
348
|
|
369
349
|
# Get results
|
370
|
-
results = _get_results(rundir,
|
371
|
-
sizing_results = _get_sizing_results(rundir)
|
350
|
+
results = _get_results(rundir, workflow_time, annual_csv_path, xml)
|
372
351
|
|
373
352
|
# Check outputs
|
374
|
-
|
353
|
+
hpxml_defaults_path = File.join(rundir, 'in.xml')
|
354
|
+
stron_paths = [File.join(File.dirname(__FILE__), '..', '..', 'HPXMLtoOpenStudio', 'resources', 'EPvalidator.xml')]
|
355
|
+
hpxml = HPXML.new(hpxml_path: hpxml_defaults_path, schematron_validators: stron_paths) # Validate in.xml to ensure it can be run back through OS-HPXML
|
356
|
+
if not hpxml.errors.empty?
|
357
|
+
puts 'ERRORS:'
|
358
|
+
hpxml.errors.each do |error|
|
359
|
+
puts error
|
360
|
+
end
|
361
|
+
flunk "EPvalidator.xml error in #{hpxml_defaults_path}."
|
362
|
+
end
|
363
|
+
sizing_results = _get_sizing_results(hpxml, xml)
|
364
|
+
_verify_outputs(rundir, xml, results, hpxml)
|
375
365
|
|
376
366
|
return results, sizing_results
|
377
367
|
end
|
378
368
|
|
379
|
-
def _get_results(rundir,
|
369
|
+
def _get_results(rundir, workflow_time, annual_csv_path, xml)
|
380
370
|
# Grab all outputs from reporting measure CSV annual results
|
381
371
|
results = {}
|
382
372
|
CSV.foreach(annual_csv_path) do |row|
|
@@ -385,35 +375,6 @@ class HPXMLTest < MiniTest::Test
|
|
385
375
|
results[row[0]] = Float(row[1])
|
386
376
|
end
|
387
377
|
|
388
|
-
sql_path = File.join(rundir, 'eplusout.sql')
|
389
|
-
sqlFile = OpenStudio::SqlFile.new(sql_path, false)
|
390
|
-
|
391
|
-
# Obtain HVAC capacities
|
392
|
-
# TODO: Add to reporting measure?
|
393
|
-
htg_cap_w = 0
|
394
|
-
for spd in [4, 2]
|
395
|
-
# Get capacity of highest speed for multi-speed coil
|
396
|
-
query = "SELECT SUM(Value) FROM ComponentSizes WHERE CompType='Coil:Heating:DX:MultiSpeed' AND Description LIKE '%User-Specified Speed #{spd}%Capacity' AND Units='W'"
|
397
|
-
htg_cap_w += sqlFile.execAndReturnFirstDouble(query).get
|
398
|
-
break if htg_cap_w > 0
|
399
|
-
end
|
400
|
-
query = "SELECT SUM(Value) FROM ComponentSizes WHERE ((CompType LIKE 'Coil:Heating:%' OR CompType LIKE 'Boiler:%' OR CompType LIKE 'ZONEHVAC:BASEBOARD:%') AND CompType!='Coil:Heating:DX:MultiSpeed') AND Description LIKE '%User-Specified%Capacity' AND Units='W'"
|
401
|
-
htg_cap_w += sqlFile.execAndReturnFirstDouble(query).get
|
402
|
-
results['Capacity: Heating (W)'] = htg_cap_w
|
403
|
-
|
404
|
-
clg_cap_w = 0
|
405
|
-
for spd in [4, 2]
|
406
|
-
# Get capacity of highest speed for multi-speed coil
|
407
|
-
query = "SELECT SUM(Value) FROM ComponentSizes WHERE CompType='Coil:Cooling:DX:MultiSpeed' AND Description LIKE 'User-Specified Speed #{spd}%Total%Capacity' AND Units='W'"
|
408
|
-
clg_cap_w += sqlFile.execAndReturnFirstDouble(query).get
|
409
|
-
break if clg_cap_w > 0
|
410
|
-
end
|
411
|
-
query = "SELECT SUM(Value) FROM ComponentSizes WHERE CompType LIKE 'Coil:Cooling:%' AND CompType!='Coil:Cooling:DX:MultiSpeed' AND Description LIKE '%User-Specified%Total%Capacity' AND Units='W'"
|
412
|
-
clg_cap_w += sqlFile.execAndReturnFirstDouble(query).get
|
413
|
-
results['Capacity: Cooling (W)'] = clg_cap_w
|
414
|
-
|
415
|
-
sqlFile.close
|
416
|
-
|
417
378
|
# Check discrepancy between total load and sum of component loads
|
418
379
|
if not xml.include? 'ASHRAE_Standard_140'
|
419
380
|
sum_component_htg_loads = results.select { |k, v| k.start_with? 'Component Load: Heating:' }.map { |k, v| v }.sum(0.0)
|
@@ -424,38 +385,81 @@ class HPXMLTest < MiniTest::Test
|
|
424
385
|
assert_operator(residual_clg_load.abs, :<, 0.5)
|
425
386
|
end
|
426
387
|
|
427
|
-
results[@@simulation_runtime_key] = sim_time
|
428
388
|
results[@@workflow_runtime_key] = workflow_time
|
429
389
|
|
430
390
|
return results
|
431
391
|
end
|
432
392
|
|
433
|
-
def _get_sizing_results(
|
393
|
+
def _get_sizing_results(hpxml, xml)
|
434
394
|
results = {}
|
435
|
-
|
436
|
-
|
437
|
-
|
438
|
-
|
439
|
-
|
440
|
-
|
441
|
-
|
442
|
-
|
443
|
-
|
444
|
-
results[
|
445
|
-
|
395
|
+
return if xml.include? 'ASHRAE_Standard_140'
|
396
|
+
|
397
|
+
# Heating design loads
|
398
|
+
hpxml.hvac_plant.class::HDL_ATTRS.each do |attr, element_name|
|
399
|
+
results["heating_load_#{attr.to_s.gsub('hdl_', '')} [Btuh]"] = hpxml.hvac_plant.send(attr.to_s)
|
400
|
+
end
|
401
|
+
|
402
|
+
# Cooling sensible design loads
|
403
|
+
hpxml.hvac_plant.class::CDL_SENS_ATTRS.each do |attr, element_name|
|
404
|
+
results["cooling_load_#{attr.to_s.gsub('cdl_', '')} [Btuh]"] = hpxml.hvac_plant.send(attr.to_s)
|
405
|
+
end
|
406
|
+
|
407
|
+
# Cooling latent design loads
|
408
|
+
hpxml.hvac_plant.class::CDL_LAT_ATTRS.each do |attr, element_name|
|
409
|
+
results["cooling_load_#{attr.to_s.gsub('cdl_', '')} [Btuh]"] = hpxml.hvac_plant.send(attr.to_s)
|
410
|
+
end
|
411
|
+
|
412
|
+
# Heating capacities/airflows
|
413
|
+
results['heating_capacity [Btuh]'] = 0.0
|
414
|
+
results['heating_backup_capacity [Btuh]'] = 0.0
|
415
|
+
results['heating_airflow [cfm]'] = 0.0
|
416
|
+
(hpxml.heating_systems + hpxml.heat_pumps).each do |htg_sys|
|
417
|
+
results['heating_capacity [Btuh]'] += htg_sys.heating_capacity
|
418
|
+
if htg_sys.respond_to? :backup_heating_capacity
|
419
|
+
results['heating_backup_capacity [Btuh]'] += htg_sys.backup_heating_capacity
|
420
|
+
end
|
421
|
+
results['heating_airflow [cfm]'] += htg_sys.heating_airflow_cfm
|
422
|
+
end
|
423
|
+
|
424
|
+
# Cooling capacity/airflows
|
425
|
+
results['cooling_capacity [Btuh]'] = 0.0
|
426
|
+
results['cooling_airflow [cfm]'] = 0.0
|
427
|
+
(hpxml.cooling_systems + hpxml.heat_pumps).each do |clg_sys|
|
428
|
+
results['cooling_capacity [Btuh]'] += clg_sys.cooling_capacity
|
429
|
+
results['cooling_airflow [cfm]'] += clg_sys.cooling_airflow_cfm
|
446
430
|
end
|
431
|
+
|
447
432
|
assert(!results.empty?)
|
433
|
+
|
434
|
+
if (hpxml.heating_systems + hpxml.heat_pumps).select { |h| h.fraction_heat_load_served.to_f > 0 }.empty?
|
435
|
+
# No heating equipment; check for zero heating capacities/airflows/duct loads
|
436
|
+
assert_equal(0.0, results['heating_capacity [Btuh]'])
|
437
|
+
assert_equal(0.0, results['heating_backup_capacity [Btuh]'])
|
438
|
+
assert_equal(0.0, results['heating_airflow [cfm]'])
|
439
|
+
assert_equal(0.0, results['heating_load_ducts [Btuh]'])
|
440
|
+
end
|
441
|
+
if (hpxml.cooling_systems + hpxml.heat_pumps).select { |c| c.fraction_cool_load_served.to_f > 0 }.empty?
|
442
|
+
# No cooling equipment; check for zero cooling capacities/airflows/duct loads
|
443
|
+
assert_equal(0.0, results['cooling_capacity [Btuh]'])
|
444
|
+
assert_equal(0.0, results['cooling_airflow [cfm]'])
|
445
|
+
assert_equal(0.0, results['cooling_load_sens_ducts [Btuh]'])
|
446
|
+
assert_equal(0.0, results['cooling_load_lat_ducts [Btuh]'])
|
447
|
+
end
|
448
|
+
if hpxml.hvac_distributions.map { |dist| dist.ducts.size }.empty?
|
449
|
+
# No ducts; check for zero duct loads
|
450
|
+
assert_equal(0.0, results['heating_load_ducts [Btuh]'])
|
451
|
+
assert_equal(0.0, results['cooling_load_sens_ducts [Btuh]'])
|
452
|
+
assert_equal(0.0, results['cooling_load_lat_ducts [Btuh]'])
|
453
|
+
end
|
454
|
+
|
448
455
|
return results
|
449
456
|
end
|
450
457
|
|
451
|
-
def _verify_outputs(
|
458
|
+
def _verify_outputs(rundir, hpxml_path, results, hpxml)
|
452
459
|
sql_path = File.join(rundir, 'eplusout.sql')
|
453
460
|
assert(File.exist? sql_path)
|
454
461
|
|
455
462
|
sqlFile = OpenStudio::SqlFile.new(sql_path, false)
|
456
|
-
hpxml_defaults_path = File.join(rundir, 'in.xml')
|
457
|
-
hpxml = HPXML.new(hpxml_path: hpxml_defaults_path)
|
458
|
-
HVAC.apply_shared_systems(hpxml)
|
459
463
|
|
460
464
|
# Collapse windows further using same logic as measure.rb
|
461
465
|
hpxml.windows.each do |window|
|
@@ -469,10 +473,11 @@ class HPXMLTest < MiniTest::Test
|
|
469
473
|
next if log_line.include? 'Warning: Could not load nokogiri, no HPXML validation performed.'
|
470
474
|
next if log_line.start_with? 'Info: '
|
471
475
|
next if log_line.start_with? 'Executing command'
|
472
|
-
next if (log_line.start_with?('Heat ') || log_line.start_with?('Cool ')) && log_line.include?('=')
|
473
476
|
next if log_line.include? "-cache.csv' could not be found; regenerating it."
|
474
|
-
next if log_line.include?('Warning: HVACDistribution') && log_line.include?('has ducts entirely within conditioned space but there is non-zero leakage to the outside.')
|
475
477
|
|
478
|
+
if hpxml_path.include? 'base-atticroof-conditioned.xml'
|
479
|
+
next if log_line.include?('Ducts are entirely within conditioned space but there is moderate leakage to the outside. Leakage to the outside is typically zero or near-zero in these situations, consider revising leakage values. Leakage will be modeled as heat lost to the ambient environment.')
|
480
|
+
end
|
476
481
|
if hpxml.clothes_washers.empty?
|
477
482
|
next if log_line.include? 'No clothes washer specified, the model will not include clothes washer energy use.'
|
478
483
|
end
|
@@ -489,13 +494,13 @@ class HPXMLTest < MiniTest::Test
|
|
489
494
|
next if log_line.include? 'No cooking range specified, the model will not include cooking range/oven energy use.'
|
490
495
|
end
|
491
496
|
if hpxml.water_heating_systems.empty?
|
492
|
-
next if log_line.include? 'No water
|
497
|
+
next if log_line.include? 'No water heating specified, the model will not include water heating energy use.'
|
493
498
|
end
|
494
499
|
if (hpxml.heating_systems + hpxml.heat_pumps).select { |h| h.fraction_heat_load_served.to_f > 0 }.empty?
|
495
|
-
next if log_line.include? 'No heating
|
500
|
+
next if log_line.include? 'No space heating specified, the model will not include space heating energy use.'
|
496
501
|
end
|
497
502
|
if (hpxml.cooling_systems + hpxml.heat_pumps).select { |c| c.fraction_cool_load_served.to_f > 0 }.empty?
|
498
|
-
next if log_line.include? 'No cooling
|
503
|
+
next if log_line.include? 'No space cooling specified, the model will not include space cooling energy use.'
|
499
504
|
end
|
500
505
|
if hpxml.plug_loads.select { |p| p.plug_load_type == HPXML::PlugLoadTypeOther }.empty?
|
501
506
|
next if log_line.include? "No '#{HPXML::PlugLoadTypeOther}' plug loads specified, the model will not include misc plug load energy use."
|
@@ -506,6 +511,9 @@ class HPXMLTest < MiniTest::Test
|
|
506
511
|
if hpxml.lighting_groups.empty?
|
507
512
|
next if log_line.include? 'No lighting specified, the model will not include lighting energy use.'
|
508
513
|
end
|
514
|
+
if hpxml.windows.empty?
|
515
|
+
next if log_line.include? 'No windows specified, the model will not include window heat transfer.'
|
516
|
+
end
|
509
517
|
|
510
518
|
flunk "Unexpected warning found in run.log: #{log_line}"
|
511
519
|
end
|
@@ -567,10 +575,19 @@ class HPXMLTest < MiniTest::Test
|
|
567
575
|
if hpxml.cooling_systems.select { |c| c.cooling_system_type == HPXML::HVACTypeRoomAirConditioner }.size > 0
|
568
576
|
next if err_line.include? 'GetDXCoils: Coil:Cooling:DX:SingleSpeed="ROOM AC CLG COIL" curve values' # TODO: Double-check Room AC curves
|
569
577
|
end
|
570
|
-
if hpxml.hvac_distributions.select { |d| d.
|
578
|
+
if hpxml.hvac_distributions.select { |d| d.air_type.to_s == HPXML::AirTypeFanCoil }.size > 0
|
571
579
|
next if err_line.include? 'In calculating the design coil UA for Coil:Cooling:Water' # Warning for unused cooling coil for fan coil
|
572
580
|
end
|
573
|
-
if hpxml_path.include?('
|
581
|
+
if hpxml_path.include?('ASHRAE_Standard_140') || (hpxml.windows.size == 0)
|
582
|
+
next if err_line.include? 'GetShadowingInput: DetailedSkyDiffuseModeling is chosen but not needed'
|
583
|
+
end
|
584
|
+
if hpxml_path.include? 'base-enclosure-split-surfaces2.xml'
|
585
|
+
next if err_line.include? 'GetSurfaceData: Very small surface area' # FUTURE: Prevent this warning
|
586
|
+
end
|
587
|
+
if hpxml_path.include?('ground-to-air-heat-pump-cooling-only.xml') || hpxml_path.include?('ground-to-air-heat-pump-heating-only.xml')
|
588
|
+
next if err_line.include? 'COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT' # heating capacity is > 20% different than cooling capacity; safe to ignore
|
589
|
+
end
|
590
|
+
if hpxml_path.include?('base-schedules-stochastic.xml') || hpxml_path.include?('base-schedules-stochastic-vacant.xml') || hpxml_path.include?('base-schedules-user-specified.xml')
|
574
591
|
next if err_line.include?('GetCurrentScheduleValue: Schedule=') && err_line.include?('is a Schedule:File')
|
575
592
|
end
|
576
593
|
|
@@ -665,9 +682,11 @@ class HPXMLTest < MiniTest::Test
|
|
665
682
|
num_expected_kiva_instances = { 'base-foundation-ambient.xml' => 0, # no foundation in contact w/ ground
|
666
683
|
'base-foundation-multiple.xml' => 2, # additional instance for 2nd foundation type
|
667
684
|
'base-enclosure-2stories-garage.xml' => 2, # additional instance for garage
|
685
|
+
'base-foundation-basement-garage.xml' => 2, # additional instance for garage
|
668
686
|
'base-enclosure-garage.xml' => 2, # additional instance for garage
|
669
687
|
'base-foundation-walkout-basement.xml' => 4, # 3 foundation walls plus a no-wall exposed perimeter
|
670
|
-
'base-foundation-complex.xml' => 10
|
688
|
+
'base-foundation-complex.xml' => 10, # lots of foundations for testing
|
689
|
+
'base-enclosure-split-surfaces2.xml' => 81 } # lots of foundations for testing
|
671
690
|
|
672
691
|
if not num_expected_kiva_instances[File.basename(hpxml_path)].nil?
|
673
692
|
assert_equal(num_expected_kiva_instances[File.basename(hpxml_path)], num_kiva_instances)
|
@@ -982,154 +1001,14 @@ class HPXMLTest < MiniTest::Test
|
|
982
1001
|
assert_in_epsilon(hpxml_value, sql_value, 0.02)
|
983
1002
|
end
|
984
1003
|
|
985
|
-
# HVAC Heating Systems
|
986
|
-
hpxml.heating_systems.each do |heating_system|
|
987
|
-
next unless heating_system.fraction_heat_load_served > 0
|
988
|
-
next unless hpxml.heating_systems.size == 1
|
989
|
-
|
990
|
-
next unless (not heating_system.fan_watts.nil?) || (not heating_system.fan_watts_per_cfm.nil?)
|
991
|
-
# Compare fan power from timeseries output
|
992
|
-
next if hpxml.cooling_systems.size + hpxml.heat_pumps.size > 0 # Skip if other system types (which could result in A) multiple supply fans or B) different supply fan power consumption in the cooling season)
|
993
|
-
|
994
|
-
if not heating_system.fan_watts.nil?
|
995
|
-
hpxml_value = heating_system.fan_watts
|
996
|
-
else
|
997
|
-
query = "SELECT SUM(Value) FROM ComponentSizes WHERE Description='User-Specified Heating Supply Air Flow Rate'"
|
998
|
-
heating_cfm = UnitConversions.convert(sqlFile.execAndReturnFirstDouble(query).get, 'm^3/s', 'cfm')
|
999
|
-
hpxml_value = heating_system.fan_watts_per_cfm * heating_cfm
|
1000
|
-
end
|
1001
|
-
query = "SELECT SUM(VariableValue) FROM ReportVariableData WHERE ReportVariableDataDictionaryIndex IN (SELECT ReportVariableDataDictionaryIndex FROM ReportVariableDataDictionary WHERE VariableType='Avg' AND VariableName='Fan Runtime Fraction' AND ReportingFrequency='Run Period')"
|
1002
|
-
avg_rtf = sqlFile.execAndReturnFirstDouble(query).get
|
1003
|
-
query = "SELECT SUM(VariableValue) FROM ReportVariableData WHERE ReportVariableDataDictionaryIndex IN (SELECT ReportVariableDataDictionaryIndex FROM ReportVariableDataDictionary WHERE VariableType='Avg' AND VariableName='Fan Electricity Rate' AND ReportingFrequency='Run Period')"
|
1004
|
-
avg_w = sqlFile.execAndReturnFirstDouble(query).get
|
1005
|
-
sql_value = avg_w / avg_rtf
|
1006
|
-
assert_in_epsilon(sql_value, hpxml_value, 0.01)
|
1007
|
-
end
|
1008
|
-
|
1009
|
-
# HVAC Cooling Systems
|
1010
|
-
hpxml.cooling_systems.each do |cooling_system|
|
1011
|
-
next unless cooling_system.fraction_cool_load_served > 0
|
1012
|
-
next unless hpxml.cooling_systems.size == 1
|
1013
|
-
next unless not cooling_system.fan_watts_per_cfm.nil?
|
1014
|
-
next if hpxml.heating_systems.size + hpxml.heat_pumps.size > 0 # Skip if other system types (which could result in A) multiple supply fans or B) different supply fan power consumption in the heating season)
|
1015
|
-
next unless cooling_system.compressor_type == HPXML::HVACCompressorTypeSingleStage
|
1016
|
-
|
1017
|
-
# Compare fan power from timeseries output
|
1018
|
-
query = "SELECT SUM(Value) FROM ComponentSizes WHERE Description='User-Specified Cooling Supply Air Flow Rate'"
|
1019
|
-
cooling_cfm = UnitConversions.convert(sqlFile.execAndReturnFirstDouble(query).get, 'm^3/s', 'cfm')
|
1020
|
-
hpxml_value = cooling_system.fan_watts_per_cfm * cooling_cfm
|
1021
|
-
query = "SELECT SUM(VariableValue) FROM ReportVariableData WHERE ReportVariableDataDictionaryIndex IN (SELECT ReportVariableDataDictionaryIndex FROM ReportVariableDataDictionary WHERE VariableType='Avg' AND VariableName='Fan Runtime Fraction' AND ReportingFrequency='Run Period')"
|
1022
|
-
avg_rtf = sqlFile.execAndReturnFirstDouble(query).get
|
1023
|
-
query = "SELECT SUM(VariableValue) FROM ReportVariableData WHERE ReportVariableDataDictionaryIndex IN (SELECT ReportVariableDataDictionaryIndex FROM ReportVariableDataDictionary WHERE VariableType='Avg' AND VariableName='Fan Electricity Rate' AND ReportingFrequency='Run Period')"
|
1024
|
-
avg_w = sqlFile.execAndReturnFirstDouble(query).get
|
1025
|
-
sql_value = avg_w / avg_rtf
|
1026
|
-
assert_in_epsilon(sql_value, hpxml_value, 0.01)
|
1027
|
-
end
|
1028
|
-
|
1029
|
-
# HVAC Capacities
|
1030
|
-
htg_cap = nil
|
1031
|
-
clg_cap = nil
|
1032
|
-
hpxml.heating_systems.each do |heating_system|
|
1033
|
-
htg_sys_cap = heating_system.heating_capacity.to_f
|
1034
|
-
if htg_sys_cap > 0
|
1035
|
-
htg_cap = 0 if htg_cap.nil?
|
1036
|
-
htg_cap += htg_sys_cap
|
1037
|
-
end
|
1038
|
-
end
|
1039
|
-
hpxml.cooling_systems.each do |cooling_system|
|
1040
|
-
clg_sys_cap = cooling_system.cooling_capacity.to_f
|
1041
|
-
clg_cap_mult = 1.0
|
1042
|
-
if cooling_system.cooling_system_type == HPXML::HVACTypeMiniSplitAirConditioner
|
1043
|
-
# TODO: Generalize this
|
1044
|
-
clg_cap_mult = 1.20
|
1045
|
-
end
|
1046
|
-
if clg_sys_cap > 0
|
1047
|
-
clg_cap = 0 if clg_cap.nil?
|
1048
|
-
clg_cap += (clg_sys_cap * clg_cap_mult)
|
1049
|
-
end
|
1050
|
-
end
|
1051
|
-
hpxml.heat_pumps.each do |heat_pump|
|
1052
|
-
hp_cap_clg = heat_pump.cooling_capacity.to_f
|
1053
|
-
hp_cap_htg = heat_pump.heating_capacity.to_f
|
1054
|
-
clg_cap_mult = 1.0
|
1055
|
-
htg_cap_mult = 1.0
|
1056
|
-
if heat_pump.heat_pump_type == HPXML::HVACTypeHeatPumpMiniSplit
|
1057
|
-
# TODO: Generalize this
|
1058
|
-
clg_cap_mult = 1.20
|
1059
|
-
htg_cap_mult = 1.20
|
1060
|
-
elsif (heat_pump.heat_pump_type == HPXML::HVACTypeHeatPumpAirToAir) && (heat_pump.cooling_efficiency_seer > 21)
|
1061
|
-
# TODO: Generalize this
|
1062
|
-
htg_cap_mult = 1.17
|
1063
|
-
end
|
1064
|
-
supp_hp_cap = heat_pump.backup_heating_capacity.to_f
|
1065
|
-
if hp_cap_clg > 0
|
1066
|
-
clg_cap = 0 if clg_cap.nil?
|
1067
|
-
clg_cap += (hp_cap_clg * clg_cap_mult)
|
1068
|
-
end
|
1069
|
-
if hp_cap_htg > 0
|
1070
|
-
htg_cap = 0 if htg_cap.nil?
|
1071
|
-
htg_cap += (hp_cap_htg * htg_cap_mult)
|
1072
|
-
end
|
1073
|
-
if supp_hp_cap > 0
|
1074
|
-
htg_cap = 0 if htg_cap.nil?
|
1075
|
-
htg_cap += supp_hp_cap
|
1076
|
-
end
|
1077
|
-
end
|
1078
|
-
if not clg_cap.nil?
|
1079
|
-
sql_value = UnitConversions.convert(results['Capacity: Cooling (W)'], 'W', 'Btu/hr')
|
1080
|
-
if clg_cap == 0
|
1081
|
-
assert_operator(sql_value, :<, 1)
|
1082
|
-
elsif clg_cap > 0
|
1083
|
-
if hpxml.header.allow_increased_fixed_capacities
|
1084
|
-
assert_operator(sql_value, :>=, clg_cap)
|
1085
|
-
else
|
1086
|
-
assert_in_epsilon(clg_cap, sql_value, 0.01)
|
1087
|
-
end
|
1088
|
-
else # autosized
|
1089
|
-
assert_operator(sql_value, :>, 1)
|
1090
|
-
end
|
1091
|
-
end
|
1092
|
-
if not htg_cap.nil?
|
1093
|
-
sql_value = UnitConversions.convert(results['Capacity: Heating (W)'], 'W', 'Btu/hr')
|
1094
|
-
if htg_cap == 0
|
1095
|
-
assert_operator(sql_value, :<, 1)
|
1096
|
-
elsif htg_cap > 0
|
1097
|
-
if hpxml.header.allow_increased_fixed_capacities
|
1098
|
-
assert_operator(sql_value, :>=, htg_cap)
|
1099
|
-
else
|
1100
|
-
assert_in_epsilon(htg_cap, sql_value, 0.01)
|
1101
|
-
end
|
1102
|
-
else # autosized
|
1103
|
-
assert_operator(sql_value, :>, 1)
|
1104
|
-
end
|
1105
|
-
end
|
1106
|
-
|
1107
1004
|
# HVAC Load Fractions
|
1108
|
-
if not hpxml_path.include? 'location-miami'
|
1005
|
+
if (not hpxml_path.include? 'location-miami') && (not hpxml_path.include? 'location-honolulu') && (not hpxml_path.include? 'location-phoenix')
|
1109
1006
|
htg_energy = results.select { |k, v| (k.include?(': Heating (MBtu)') || k.include?(': Heating Fans/Pumps (MBtu)')) && !k.include?('Load') }.map { |k, v| v }.sum(0.0)
|
1110
1007
|
assert_equal(hpxml.total_fraction_heat_load_served > 0, htg_energy > 0)
|
1111
1008
|
end
|
1112
1009
|
clg_energy = results.select { |k, v| (k.include?(': Cooling (MBtu)') || k.include?(': Cooling Fans/Pumps (MBtu)')) && !k.include?('Load') }.map { |k, v| v }.sum(0.0)
|
1113
1010
|
assert_equal(hpxml.total_fraction_cool_load_served > 0, clg_energy > 0)
|
1114
1011
|
|
1115
|
-
# Water Heater
|
1116
|
-
if hpxml.water_heating_systems.select { |wh| [HPXML::WaterHeaterTypeCombiStorage, HPXML::WaterHeaterTypeCombiTankless].include? wh.water_heater_type }.size > 0
|
1117
|
-
query = "SELECT SUM(ABS(VariableValue)/1000000000) FROM ReportVariableData WHERE ReportVariableDataDictionaryIndex IN (SELECT ReportVariableDataDictionaryIndex FROM ReportVariableDataDictionary WHERE VariableType='Sum' AND VariableName='Fluid Heat Exchanger Heat Transfer Energy' AND ReportingFrequency='Run Period' AND VariableUnits='J')"
|
1118
|
-
combi_hx_load = sqlFile.execAndReturnFirstDouble(query).get.round(2)
|
1119
|
-
query = "SELECT SUM(ABS(VariableValue)/1000000000) FROM ReportVariableData WHERE ReportVariableDataDictionaryIndex IN (SELECT ReportVariableDataDictionaryIndex FROM ReportVariableDataDictionary WHERE VariableType='Sum' AND VariableName='Boiler Heating Energy' AND ReportingFrequency='Run Period' AND VariableUnits='J')"
|
1120
|
-
combi_htg_load = sqlFile.execAndReturnFirstDouble(query).get.round(2)
|
1121
|
-
|
1122
|
-
# Check combi system energy balance
|
1123
|
-
query = "SELECT SUM(ABS(VariableValue)/1000000000) FROM ReportVariableData WHERE ReportVariableDataDictionaryIndex IN (SELECT ReportVariableDataDictionaryIndex FROM ReportVariableDataDictionary WHERE VariableType='Sum' AND VariableName='Water Heater Source Side Heat Transfer Energy' AND VariableUnits='J')"
|
1124
|
-
combi_tank_source_load = sqlFile.execAndReturnFirstDouble(query).get.round(2)
|
1125
|
-
assert_in_epsilon(combi_hx_load, combi_tank_source_load, 0.02)
|
1126
|
-
|
1127
|
-
# Check boiler, hx, pump, heating coil energy balance
|
1128
|
-
query = "SELECT SUM(ABS(VariableValue)/1000000000) FROM ReportVariableData WHERE ReportVariableDataDictionaryIndex IN (SELECT ReportVariableDataDictionaryIndex FROM ReportVariableDataDictionary WHERE VariableType='Sum' AND VariableName='Baseboard Total Heating Energy' AND VariableUnits='J')"
|
1129
|
-
boiler_space_heating_load = sqlFile.execAndReturnFirstDouble(query).get.round(2)
|
1130
|
-
assert_in_epsilon(combi_hx_load + boiler_space_heating_load, combi_htg_load, 0.02)
|
1131
|
-
end
|
1132
|
-
|
1133
1012
|
# Mechanical Ventilation
|
1134
1013
|
fan_cfis = hpxml.ventilation_fans.select { |vent_mech| vent_mech.used_for_whole_building_ventilation && (vent_mech.fan_type == HPXML::MechVentTypeCFIS) }
|
1135
1014
|
fan_sup = hpxml.ventilation_fans.select { |vent_mech| vent_mech.used_for_whole_building_ventilation && (vent_mech.fan_type == HPXML::MechVentTypeSupply) }
|
@@ -1139,43 +1018,36 @@ class HPXMLTest < MiniTest::Test
|
|
1139
1018
|
vent_fan_bath = hpxml.ventilation_fans.select { |vent_mech| vent_mech.used_for_local_ventilation && (vent_mech.fan_location == HPXML::LocationBath) }
|
1140
1019
|
|
1141
1020
|
if not (fan_cfis + fan_sup + fan_exh + fan_bal + vent_fan_kitchen + vent_fan_bath).empty?
|
1142
|
-
mv_energy = UnitConversions.convert(results['Electricity: Mech Vent (MBtu)'], 'MBtu', 'GJ')
|
1021
|
+
mv_energy = UnitConversions.convert(results['End Use: Electricity: Mech Vent (MBtu)'], 'MBtu', 'GJ')
|
1143
1022
|
|
1144
1023
|
if not fan_cfis.empty?
|
1145
|
-
|
1146
|
-
|
1147
|
-
|
1148
|
-
|
1149
|
-
|
1150
|
-
if fan_gj > 0
|
1151
|
-
assert_operator(cfis_energy, :>, 0)
|
1152
|
-
assert_operator(cfis_energy, :<, fan_gj)
|
1153
|
-
else
|
1154
|
-
assert_equal(cfis_energy, 0.0)
|
1024
|
+
if (fan_sup + fan_exh + fan_bal + vent_fan_kitchen + vent_fan_bath).empty?
|
1025
|
+
# CFIS only, check for positive mech vent energy that is less than the energy if it had run 24/7
|
1026
|
+
fan_gj = fan_cfis.map { |vent_mech| UnitConversions.convert(vent_mech.unit_fan_power * vent_mech.hours_in_operation * 365.0, 'Wh', 'GJ') }.sum(0.0)
|
1027
|
+
assert_operator(mv_energy, :>, 0)
|
1028
|
+
assert_operator(mv_energy, :<, fan_gj)
|
1155
1029
|
end
|
1156
|
-
|
1157
|
-
|
1158
|
-
|
1159
|
-
|
1160
|
-
|
1161
|
-
|
1162
|
-
|
1163
|
-
|
1164
|
-
|
1165
|
-
|
1166
|
-
|
1167
|
-
|
1168
|
-
|
1169
|
-
|
1170
|
-
|
1171
|
-
|
1172
|
-
|
1173
|
-
|
1174
|
-
|
1175
|
-
|
1030
|
+
else
|
1031
|
+
# Supply, exhaust, ERV, HRV, etc., check for appropriate mech vent energy
|
1032
|
+
fan_gj = 0
|
1033
|
+
if not fan_sup.empty?
|
1034
|
+
fan_gj += fan_sup.map { |vent_mech| UnitConversions.convert(vent_mech.unit_fan_power * vent_mech.hours_in_operation * 365.0, 'Wh', 'GJ') }.sum(0.0)
|
1035
|
+
end
|
1036
|
+
if not fan_exh.empty?
|
1037
|
+
fan_gj += fan_exh.map { |vent_mech| UnitConversions.convert(vent_mech.unit_fan_power * vent_mech.hours_in_operation * 365.0, 'Wh', 'GJ') }.sum(0.0)
|
1038
|
+
end
|
1039
|
+
if not fan_bal.empty?
|
1040
|
+
fan_gj += fan_bal.map { |vent_mech| UnitConversions.convert(vent_mech.unit_fan_power * vent_mech.hours_in_operation * 365.0, 'Wh', 'GJ') }.sum(0.0)
|
1041
|
+
end
|
1042
|
+
if not vent_fan_kitchen.empty?
|
1043
|
+
fan_gj += vent_fan_kitchen.map { |vent_kitchen| UnitConversions.convert(vent_kitchen.unit_fan_power * vent_kitchen.hours_in_operation * vent_kitchen.quantity * 365.0, 'Wh', 'GJ') }.sum(0.0)
|
1044
|
+
end
|
1045
|
+
if not vent_fan_bath.empty?
|
1046
|
+
fan_gj += vent_fan_bath.map { |vent_bath| UnitConversions.convert(vent_bath.unit_fan_power * vent_bath.hours_in_operation * vent_bath.quantity * 365.0, 'Wh', 'GJ') }.sum(0.0)
|
1047
|
+
end
|
1048
|
+
# Maximum error that can be caused by rounding
|
1049
|
+
assert_in_delta(mv_energy, fan_gj, 0.006)
|
1176
1050
|
end
|
1177
|
-
# Maximum error that can be caused by rounding
|
1178
|
-
assert_in_delta(mv_energy, fan_gj, 0.006)
|
1179
1051
|
end
|
1180
1052
|
|
1181
1053
|
# Clothes Washer
|
@@ -1239,8 +1111,10 @@ class HPXMLTest < MiniTest::Test
|
|
1239
1111
|
end
|
1240
1112
|
|
1241
1113
|
# Lighting
|
1242
|
-
ltg_energy = results.select { |k, v| k.include? 'Electricity: Lighting' }.map { |k, v| v }.sum(0.0)
|
1243
|
-
|
1114
|
+
ltg_energy = results.select { |k, v| k.include? 'End Use: Electricity: Lighting' }.map { |k, v| v }.sum(0.0)
|
1115
|
+
if hpxml.header.schedules_path.nil?
|
1116
|
+
assert_equal(hpxml.lighting_groups.size > 0, ltg_energy > 0)
|
1117
|
+
end
|
1244
1118
|
|
1245
1119
|
# Get fuels
|
1246
1120
|
htg_fuels = []
|
@@ -1270,11 +1144,11 @@ class HPXMLTest < MiniTest::Test
|
|
1270
1144
|
HPXML::FuelTypeCoal].each do |fuel|
|
1271
1145
|
fuel_name = fuel.split.map(&:capitalize).join(' ')
|
1272
1146
|
fuel_name += ' Cord' if fuel_name == 'Wood'
|
1273
|
-
energy_htg = results.fetch("#{fuel_name}: Heating (MBtu)", 0)
|
1274
|
-
energy_dhw = results.fetch("#{fuel_name}: Hot Water (MBtu)", 0)
|
1275
|
-
energy_cd = results.fetch("#{fuel_name}: Clothes Dryer (MBtu)", 0)
|
1276
|
-
energy_cr = results.fetch("#{fuel_name}: Range/Oven (MBtu)", 0)
|
1277
|
-
if htg_fuels.include?(fuel) && (not hpxml_path.include? 'location-miami')
|
1147
|
+
energy_htg = results.fetch("End Use: #{fuel_name}: Heating (MBtu)", 0)
|
1148
|
+
energy_dhw = results.fetch("End Use: #{fuel_name}: Hot Water (MBtu)", 0)
|
1149
|
+
energy_cd = results.fetch("End Use: #{fuel_name}: Clothes Dryer (MBtu)", 0)
|
1150
|
+
energy_cr = results.fetch("End Use: #{fuel_name}: Range/Oven (MBtu)", 0)
|
1151
|
+
if htg_fuels.include?(fuel) && (not hpxml_path.include? 'location-miami') && (not hpxml_path.include? 'location-honolulu') && (not hpxml_path.include? 'location-phoenix')
|
1278
1152
|
assert_operator(energy_htg, :>, 0)
|
1279
1153
|
else
|
1280
1154
|
assert_equal(0, energy_htg)
|
@@ -1355,7 +1229,7 @@ class HPXMLTest < MiniTest::Test
|
|
1355
1229
|
puts "Wrote HVAC sizing results to #{csv_out}."
|
1356
1230
|
end
|
1357
1231
|
|
1358
|
-
def _write_ashrae_140_results(all_results,
|
1232
|
+
def _write_ashrae_140_results(all_results, csv_out)
|
1359
1233
|
require 'csv'
|
1360
1234
|
|
1361
1235
|
htg_loads = {}
|
@@ -1363,7 +1237,6 @@ class HPXMLTest < MiniTest::Test
|
|
1363
1237
|
CSV.open(csv_out, 'w') do |csv|
|
1364
1238
|
csv << ['Test Case', 'Annual Heating Load [MMBtu]', 'Annual Cooling Load [MMBtu]']
|
1365
1239
|
all_results.sort.each do |xml, xml_results|
|
1366
|
-
next unless xml.include? ashrae140_dir
|
1367
1240
|
next unless xml.include? 'C.xml'
|
1368
1241
|
|
1369
1242
|
htg_load = xml_results['Load: Heating (MBtu)'].round(2)
|
@@ -1372,7 +1245,6 @@ class HPXMLTest < MiniTest::Test
|
|
1372
1245
|
htg_loads[test_name] = htg_load
|
1373
1246
|
end
|
1374
1247
|
all_results.sort.each do |xml, xml_results|
|
1375
|
-
next unless xml.include? ashrae140_dir
|
1376
1248
|
next unless xml.include? 'L.xml'
|
1377
1249
|
|
1378
1250
|
clg_load = xml_results['Load: Cooling (MBtu)'].round(2)
|