openstudio-standards 0.8.1 → 0.8.3
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/lib/openstudio-standards/exterior_lighting/data/entryways.csv +1 -1
- data/lib/openstudio-standards/exterior_lighting/data/parking.csv +1 -1
- data/lib/openstudio-standards/exterior_lighting/information.rb +7 -7
- data/lib/openstudio-standards/hvac/exhaust/data/typical_exhaust.csv +1 -1
- data/lib/openstudio-standards/infiltration/data/NISTInfiltrationCorrelations.csv +1 -1
- data/lib/openstudio-standards/infiltration/nist_infiltration.rb +1 -1
- data/lib/openstudio-standards/refrigeration/create_case.rb +60 -23
- data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -2
- data/lib/openstudio-standards/refrigeration/create_typical_refrigeration.rb +8 -6
- data/lib/openstudio-standards/refrigeration/create_walkin.rb +59 -24
- data/lib/openstudio-standards/refrigeration/data/refrigerated_cases.csv +31 -31
- data/lib/openstudio-standards/refrigeration/data/refrigerated_walkins.csv +76 -76
- data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +1 -1
- data/lib/openstudio-standards/refrigeration/data/typical_refrigerated_cases.csv +1 -1
- data/lib/openstudio-standards/refrigeration/data/typical_refrigerated_walkins.csv +1 -1
- data/lib/openstudio-standards/refrigeration/information.rb +4 -4
- data/lib/openstudio-standards/service_water_heating/create_typical.rb +10 -10
- data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +10 -0
- data/lib/openstudio-standards/service_water_heating/create_water_heating_loop.rb +16 -3
- data/lib/openstudio-standards/service_water_heating/data/convert_data.rb +9 -9
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.csv +49 -49
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.json +159 -159
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +7 -18
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +10 -20
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -15
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +5 -6
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +93 -43
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +135 -37
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.Model.rb +9 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +648 -326
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +371 -90
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +66 -22
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +1012 -296
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +443 -79
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +66 -22
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +672 -306
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +354 -74
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +72 -24
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +930 -604
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +415 -111
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +72 -24
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.computer_room_acs.json +602 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +1005 -333
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +642 -88
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +78 -26
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.computer_room_acs.json +722 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +1741 -426
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +1108 -111
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +186 -62
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +62 -232
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +7 -18
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +9 -7
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps.json +154 -69
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps_heating.json +72 -72
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.water_heaters.json +382 -295
- data/lib/openstudio-standards/standards/deer/data/deer.schedules.json +62 -232
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps_heating.json +6 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +6 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +8 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +20 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +10 -0
- data/lib/openstudio-standards/utilities/simulation.rb +3 -2
- data/lib/openstudio-standards/version.rb +1 -1
- metadata +2 -2
@@ -1,164 +1,445 @@
|
|
1
1
|
{
|
2
2
|
"heat_pumps_heating": [
|
3
3
|
{
|
4
|
-
"
|
4
|
+
"equipment_type": "PTHP",
|
5
5
|
"cooling_type": "AirCooled",
|
6
|
-
"
|
7
|
-
"
|
8
|
-
"
|
6
|
+
"configuration": null,
|
7
|
+
"subcategory": null,
|
8
|
+
"application": "New Construction",
|
9
|
+
"rating_condition": null,
|
10
|
+
"electric_power_phase": null,
|
11
|
+
"region": null,
|
12
|
+
"minimum_capacity": 0,
|
13
|
+
"maximum_capacity": 9999999999,
|
9
14
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
15
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
16
|
"minimum_heating_seasonal_performance_factor": null,
|
17
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
12
18
|
"minimum_coefficient_of_performance_heating": null,
|
13
|
-
"minimum_energy_efficiency_ratio": null,
|
14
19
|
"pthp_cop_coefficient_1": 3.2,
|
15
20
|
"pthp_cop_coefficient_2": 0.026,
|
16
|
-
"
|
17
|
-
"
|
18
|
-
"heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
|
19
|
-
"heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
|
20
|
-
"heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
|
21
|
-
"notes": "From 90.1-2004 Table 6.8.1D"
|
21
|
+
"off_mode_power": null,
|
22
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
22
23
|
},
|
23
24
|
{
|
24
|
-
"
|
25
|
+
"equipment_type": "PTHP",
|
25
26
|
"cooling_type": "AirCooled",
|
26
|
-
"
|
27
|
-
"
|
28
|
-
"
|
27
|
+
"configuration": null,
|
28
|
+
"subcategory": null,
|
29
|
+
"application": "Replacements",
|
30
|
+
"rating_condition": null,
|
31
|
+
"electric_power_phase": null,
|
32
|
+
"region": null,
|
33
|
+
"minimum_capacity": 0,
|
34
|
+
"maximum_capacity": 9999999999,
|
35
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
36
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
37
|
+
"minimum_heating_seasonal_performance_factor": null,
|
38
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
39
|
+
"minimum_coefficient_of_performance_heating": null,
|
40
|
+
"pthp_cop_coefficient_1": 2.9,
|
41
|
+
"pthp_cop_coefficient_2": 0.026,
|
42
|
+
"off_mode_power": null,
|
43
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
44
|
+
},
|
45
|
+
{
|
46
|
+
"equipment_type": "SPVHP",
|
47
|
+
"cooling_type": "AirCooled",
|
48
|
+
"configuration": null,
|
49
|
+
"subcategory": null,
|
50
|
+
"application": null,
|
51
|
+
"rating_condition": null,
|
52
|
+
"electric_power_phase": null,
|
53
|
+
"region": null,
|
54
|
+
"minimum_capacity": 0,
|
55
|
+
"maximum_capacity": 9999999999,
|
29
56
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
57
|
"end_date": "2999-09-09T00:00:00+00:00",
|
58
|
+
"minimum_heating_seasonal_performance_factor": null,
|
59
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
60
|
+
"minimum_coefficient_of_performance_heating": 2.7,
|
61
|
+
"pthp_cop_coefficient_1": null,
|
62
|
+
"pthp_cop_coefficient_2": null,
|
63
|
+
"off_mode_power": null,
|
64
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
65
|
+
},
|
66
|
+
{
|
67
|
+
"equipment_type": "Heat Pumps",
|
68
|
+
"cooling_type": "AirCooled",
|
69
|
+
"configuration": null,
|
70
|
+
"subcategory": "Single Package",
|
71
|
+
"application": null,
|
72
|
+
"rating_condition": null,
|
73
|
+
"electric_power_phase": null,
|
74
|
+
"region": null,
|
75
|
+
"minimum_capacity": 0,
|
76
|
+
"maximum_capacity": 64999.99,
|
77
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
78
|
+
"end_date": "2006-01-22T00:00:00+00:00",
|
31
79
|
"minimum_heating_seasonal_performance_factor": 6.6,
|
80
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
32
81
|
"minimum_coefficient_of_performance_heating": null,
|
33
|
-
"minimum_energy_efficiency_ratio": null,
|
34
82
|
"pthp_cop_coefficient_1": null,
|
35
83
|
"pthp_cop_coefficient_2": null,
|
36
|
-
"
|
37
|
-
"
|
38
|
-
"heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
|
39
|
-
"heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
|
40
|
-
"heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
|
41
|
-
"notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
|
84
|
+
"off_mode_power": null,
|
85
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
42
86
|
},
|
43
87
|
{
|
44
|
-
"
|
88
|
+
"equipment_type": "Heat Pumps",
|
45
89
|
"cooling_type": "AirCooled",
|
90
|
+
"configuration": null,
|
46
91
|
"subcategory": "Single Package",
|
47
|
-
"
|
48
|
-
"
|
92
|
+
"application": null,
|
93
|
+
"rating_condition": null,
|
94
|
+
"electric_power_phase": null,
|
95
|
+
"region": null,
|
96
|
+
"minimum_capacity": 0,
|
97
|
+
"maximum_capacity": 64999.99,
|
98
|
+
"start_date": "2006-01-23T00:00:00+00:00",
|
99
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
100
|
+
"minimum_heating_seasonal_performance_factor": 7.4,
|
101
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
102
|
+
"minimum_coefficient_of_performance_heating": null,
|
103
|
+
"pthp_cop_coefficient_1": null,
|
104
|
+
"pthp_cop_coefficient_2": null,
|
105
|
+
"off_mode_power": null,
|
106
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
107
|
+
},
|
108
|
+
{
|
109
|
+
"equipment_type": "Heat Pumps",
|
110
|
+
"cooling_type": "AirCooled",
|
111
|
+
"configuration": null,
|
112
|
+
"subcategory": null,
|
113
|
+
"application": null,
|
114
|
+
"rating_condition": "47F db/43F wb outdoor air",
|
115
|
+
"electric_power_phase": null,
|
116
|
+
"region": null,
|
117
|
+
"minimum_capacity": 65000,
|
118
|
+
"maximum_capacity": 134999.99,
|
49
119
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
120
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
121
|
"minimum_heating_seasonal_performance_factor": null,
|
122
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
52
123
|
"minimum_coefficient_of_performance_heating": 3.2,
|
53
|
-
"minimum_energy_efficiency_ratio": null,
|
54
124
|
"pthp_cop_coefficient_1": null,
|
55
125
|
"pthp_cop_coefficient_2": null,
|
56
|
-
"
|
57
|
-
"
|
58
|
-
"heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
|
59
|
-
"heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
|
60
|
-
"heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
|
61
|
-
"notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
|
126
|
+
"off_mode_power": null,
|
127
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
62
128
|
},
|
63
129
|
{
|
64
|
-
"
|
130
|
+
"equipment_type": "Heat Pumps",
|
65
131
|
"cooling_type": "AirCooled",
|
66
|
-
"
|
67
|
-
"
|
68
|
-
"
|
132
|
+
"configuration": null,
|
133
|
+
"subcategory": null,
|
134
|
+
"application": null,
|
135
|
+
"rating_condition": "17F db/15F wb outdoor air",
|
136
|
+
"electric_power_phase": null,
|
137
|
+
"region": null,
|
138
|
+
"minimum_capacity": 65000,
|
139
|
+
"maximum_capacity": 134999.99,
|
69
140
|
"start_date": "1919-09-09T00:00:00+00:00",
|
70
141
|
"end_date": "2999-09-09T00:00:00+00:00",
|
71
142
|
"minimum_heating_seasonal_performance_factor": null,
|
143
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
144
|
+
"minimum_coefficient_of_performance_heating": 2.2,
|
145
|
+
"pthp_cop_coefficient_1": null,
|
146
|
+
"pthp_cop_coefficient_2": null,
|
147
|
+
"off_mode_power": null,
|
148
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
149
|
+
},
|
150
|
+
{
|
151
|
+
"equipment_type": "Heat Pumps",
|
152
|
+
"cooling_type": "AirCooled",
|
153
|
+
"configuration": null,
|
154
|
+
"subcategory": null,
|
155
|
+
"application": null,
|
156
|
+
"rating_condition": "47F db/43F wb outdoor air",
|
157
|
+
"electric_power_phase": null,
|
158
|
+
"region": null,
|
159
|
+
"minimum_capacity": 135000,
|
160
|
+
"maximum_capacity": 9999999999,
|
161
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
162
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
163
|
+
"minimum_heating_seasonal_performance_factor": null,
|
164
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
72
165
|
"minimum_coefficient_of_performance_heating": 3.1,
|
73
|
-
"minimum_energy_efficiency_ratio": null,
|
74
166
|
"pthp_cop_coefficient_1": null,
|
75
167
|
"pthp_cop_coefficient_2": null,
|
76
|
-
"
|
77
|
-
"
|
78
|
-
"heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
|
79
|
-
"heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
|
80
|
-
"heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
|
81
|
-
"notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
|
168
|
+
"off_mode_power": null,
|
169
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
82
170
|
},
|
83
171
|
{
|
84
|
-
"
|
172
|
+
"equipment_type": "Heat Pumps",
|
85
173
|
"cooling_type": "AirCooled",
|
86
|
-
"
|
87
|
-
"
|
88
|
-
"
|
174
|
+
"configuration": null,
|
175
|
+
"subcategory": null,
|
176
|
+
"application": null,
|
177
|
+
"rating_condition": "17F db/15F wb outdoor air",
|
178
|
+
"electric_power_phase": null,
|
179
|
+
"region": null,
|
180
|
+
"minimum_capacity": 135000,
|
181
|
+
"maximum_capacity": 9999999999,
|
89
182
|
"start_date": "1919-09-09T00:00:00+00:00",
|
90
183
|
"end_date": "2999-09-09T00:00:00+00:00",
|
184
|
+
"minimum_heating_seasonal_performance_factor": null,
|
185
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
186
|
+
"minimum_coefficient_of_performance_heating": 2,
|
187
|
+
"pthp_cop_coefficient_1": null,
|
188
|
+
"pthp_cop_coefficient_2": null,
|
189
|
+
"off_mode_power": null,
|
190
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
191
|
+
},
|
192
|
+
{
|
193
|
+
"equipment_type": "Heat Pumps",
|
194
|
+
"cooling_type": "AirCooled",
|
195
|
+
"configuration": null,
|
196
|
+
"subcategory": "Split System",
|
197
|
+
"application": null,
|
198
|
+
"rating_condition": null,
|
199
|
+
"electric_power_phase": null,
|
200
|
+
"region": null,
|
201
|
+
"minimum_capacity": 0,
|
202
|
+
"maximum_capacity": 64999.99,
|
203
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
204
|
+
"end_date": "2006-01-22T00:00:00+00:00",
|
91
205
|
"minimum_heating_seasonal_performance_factor": 6.8,
|
206
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
92
207
|
"minimum_coefficient_of_performance_heating": null,
|
93
|
-
"minimum_energy_efficiency_ratio": null,
|
94
208
|
"pthp_cop_coefficient_1": null,
|
95
209
|
"pthp_cop_coefficient_2": null,
|
96
|
-
"
|
97
|
-
"
|
98
|
-
"heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
|
99
|
-
"heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
|
100
|
-
"heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
|
101
|
-
"notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
|
210
|
+
"off_mode_power": null,
|
211
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
102
212
|
},
|
103
213
|
{
|
104
|
-
"
|
105
|
-
"cooling_type": "
|
214
|
+
"equipment_type": "Heat Pumps",
|
215
|
+
"cooling_type": "AirCooled",
|
216
|
+
"configuration": null,
|
106
217
|
"subcategory": "Split System",
|
107
|
-
"
|
108
|
-
"
|
109
|
-
"
|
218
|
+
"application": null,
|
219
|
+
"rating_condition": null,
|
220
|
+
"electric_power_phase": null,
|
221
|
+
"region": null,
|
222
|
+
"minimum_capacity": 0,
|
223
|
+
"maximum_capacity": 64999.99,
|
224
|
+
"start_date": "2006-01-23T00:00:00+00:00",
|
110
225
|
"end_date": "2999-09-09T00:00:00+00:00",
|
111
|
-
"minimum_heating_seasonal_performance_factor":
|
226
|
+
"minimum_heating_seasonal_performance_factor": 7.4,
|
227
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
112
228
|
"minimum_coefficient_of_performance_heating": null,
|
113
|
-
"minimum_energy_efficiency_ratio": null,
|
114
229
|
"pthp_cop_coefficient_1": null,
|
115
230
|
"pthp_cop_coefficient_2": null,
|
116
|
-
"
|
117
|
-
"
|
118
|
-
"heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
|
119
|
-
"heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
|
120
|
-
"heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
|
121
|
-
"notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
|
231
|
+
"off_mode_power": null,
|
232
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
122
233
|
},
|
123
234
|
{
|
124
|
-
"
|
125
|
-
"cooling_type": "
|
235
|
+
"equipment_type": "Through the Wall",
|
236
|
+
"cooling_type": "AirCooled",
|
237
|
+
"configuration": null,
|
126
238
|
"subcategory": "Single Package",
|
127
|
-
"
|
128
|
-
"
|
239
|
+
"application": null,
|
240
|
+
"rating_condition": null,
|
241
|
+
"electric_power_phase": null,
|
242
|
+
"region": null,
|
243
|
+
"minimum_capacity": 0,
|
244
|
+
"maximum_capacity": 30000,
|
129
245
|
"start_date": "1919-09-09T00:00:00+00:00",
|
130
|
-
"end_date": "
|
246
|
+
"end_date": "2006-01-22T00:00:00+00:00",
|
131
247
|
"minimum_heating_seasonal_performance_factor": 6.6,
|
248
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
132
249
|
"minimum_coefficient_of_performance_heating": null,
|
133
|
-
"minimum_energy_efficiency_ratio": null,
|
134
250
|
"pthp_cop_coefficient_1": null,
|
135
251
|
"pthp_cop_coefficient_2": null,
|
136
|
-
"
|
137
|
-
"
|
138
|
-
"heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT",
|
139
|
-
"heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW",
|
140
|
-
"heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR",
|
141
|
-
"notes": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006"
|
252
|
+
"off_mode_power": null,
|
253
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
142
254
|
},
|
143
255
|
{
|
144
|
-
"
|
145
|
-
"cooling_type": "
|
256
|
+
"equipment_type": "Through the Wall",
|
257
|
+
"cooling_type": "AirCooled",
|
258
|
+
"configuration": null,
|
259
|
+
"subcategory": "Single Package",
|
260
|
+
"application": null,
|
261
|
+
"rating_condition": null,
|
262
|
+
"electric_power_phase": null,
|
263
|
+
"region": null,
|
264
|
+
"minimum_capacity": 0,
|
265
|
+
"maximum_capacity": 30000,
|
266
|
+
"start_date": "2006-01-23T00:00:00+00:00",
|
267
|
+
"end_date": "2010-01-22T00:00:00+00:00",
|
268
|
+
"minimum_heating_seasonal_performance_factor": 7,
|
269
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
270
|
+
"minimum_coefficient_of_performance_heating": null,
|
271
|
+
"pthp_cop_coefficient_1": null,
|
272
|
+
"pthp_cop_coefficient_2": null,
|
273
|
+
"off_mode_power": null,
|
274
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
275
|
+
},
|
276
|
+
{
|
277
|
+
"equipment_type": "Through the Wall",
|
278
|
+
"cooling_type": "AirCooled",
|
279
|
+
"configuration": null,
|
280
|
+
"subcategory": "Single Package",
|
281
|
+
"application": null,
|
282
|
+
"rating_condition": null,
|
283
|
+
"electric_power_phase": null,
|
284
|
+
"region": null,
|
285
|
+
"minimum_capacity": 0,
|
286
|
+
"maximum_capacity": 30000,
|
287
|
+
"start_date": "2010-01-23T00:00:00+00:00",
|
288
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
289
|
+
"minimum_heating_seasonal_performance_factor": 7.4,
|
290
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
291
|
+
"minimum_coefficient_of_performance_heating": null,
|
292
|
+
"pthp_cop_coefficient_1": null,
|
293
|
+
"pthp_cop_coefficient_2": null,
|
294
|
+
"off_mode_power": null,
|
295
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
296
|
+
},
|
297
|
+
{
|
298
|
+
"equipment_type": "Through the Wall",
|
299
|
+
"cooling_type": "AirCooled",
|
300
|
+
"configuration": null,
|
301
|
+
"subcategory": "Split System",
|
302
|
+
"application": null,
|
303
|
+
"rating_condition": null,
|
304
|
+
"electric_power_phase": null,
|
305
|
+
"region": null,
|
306
|
+
"minimum_capacity": 0,
|
307
|
+
"maximum_capacity": 30000,
|
308
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
309
|
+
"end_date": "2006-01-22T00:00:00+00:00",
|
310
|
+
"minimum_heating_seasonal_performance_factor": 6.8,
|
311
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
312
|
+
"minimum_coefficient_of_performance_heating": null,
|
313
|
+
"pthp_cop_coefficient_1": null,
|
314
|
+
"pthp_cop_coefficient_2": null,
|
315
|
+
"off_mode_power": null,
|
316
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
317
|
+
},
|
318
|
+
{
|
319
|
+
"equipment_type": "Through the Wall",
|
320
|
+
"cooling_type": "AirCooled",
|
321
|
+
"configuration": null,
|
322
|
+
"subcategory": "Split System",
|
323
|
+
"application": null,
|
324
|
+
"rating_condition": null,
|
325
|
+
"electric_power_phase": null,
|
326
|
+
"region": null,
|
327
|
+
"minimum_capacity": 0,
|
328
|
+
"maximum_capacity": 30000,
|
329
|
+
"start_date": "2006-01-23T00:00:00+00:00",
|
330
|
+
"end_date": "2010-01-22T00:00:00+00:00",
|
331
|
+
"minimum_heating_seasonal_performance_factor": 7.1,
|
332
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
333
|
+
"minimum_coefficient_of_performance_heating": null,
|
334
|
+
"pthp_cop_coefficient_1": null,
|
335
|
+
"pthp_cop_coefficient_2": null,
|
336
|
+
"off_mode_power": null,
|
337
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
338
|
+
},
|
339
|
+
{
|
340
|
+
"equipment_type": "Through the Wall",
|
341
|
+
"cooling_type": "AirCooled",
|
342
|
+
"configuration": null,
|
343
|
+
"subcategory": "Split System",
|
344
|
+
"application": null,
|
345
|
+
"rating_condition": null,
|
346
|
+
"electric_power_phase": null,
|
347
|
+
"region": null,
|
348
|
+
"minimum_capacity": 0,
|
349
|
+
"maximum_capacity": 30000,
|
350
|
+
"start_date": "2010-01-23T00:00:00+00:00",
|
351
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
352
|
+
"minimum_heating_seasonal_performance_factor": 7.4,
|
353
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
354
|
+
"minimum_coefficient_of_performance_heating": null,
|
355
|
+
"pthp_cop_coefficient_1": null,
|
356
|
+
"pthp_cop_coefficient_2": null,
|
357
|
+
"off_mode_power": null,
|
358
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
359
|
+
},
|
360
|
+
{
|
361
|
+
"equipment_type": "Small Duct High Velocity",
|
362
|
+
"cooling_type": "AirCooled",
|
363
|
+
"configuration": null,
|
146
364
|
"subcategory": "Split System",
|
147
|
-
"
|
148
|
-
"
|
365
|
+
"application": null,
|
366
|
+
"rating_condition": null,
|
367
|
+
"electric_power_phase": null,
|
368
|
+
"region": null,
|
369
|
+
"minimum_capacity": 0,
|
370
|
+
"maximum_capacity": 64999.99,
|
149
371
|
"start_date": "1919-09-09T00:00:00+00:00",
|
150
372
|
"end_date": "2999-09-09T00:00:00+00:00",
|
151
373
|
"minimum_heating_seasonal_performance_factor": 6.8,
|
374
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
152
375
|
"minimum_coefficient_of_performance_heating": null,
|
153
|
-
"minimum_energy_efficiency_ratio": null,
|
154
376
|
"pthp_cop_coefficient_1": null,
|
155
377
|
"pthp_cop_coefficient_2": null,
|
156
|
-
"
|
157
|
-
"
|
158
|
-
|
159
|
-
|
160
|
-
"
|
161
|
-
"
|
378
|
+
"off_mode_power": null,
|
379
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
380
|
+
},
|
381
|
+
{
|
382
|
+
"equipment_type": "Heat Pumps",
|
383
|
+
"cooling_type": "WaterSource",
|
384
|
+
"configuration": null,
|
385
|
+
"subcategory": null,
|
386
|
+
"application": null,
|
387
|
+
"rating_condition": null,
|
388
|
+
"electric_power_phase": null,
|
389
|
+
"region": null,
|
390
|
+
"minimum_capacity": 0,
|
391
|
+
"maximum_capacity": 134999.99,
|
392
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
393
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
394
|
+
"minimum_heating_seasonal_performance_factor": null,
|
395
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
396
|
+
"minimum_coefficient_of_performance_heating": 4.2,
|
397
|
+
"pthp_cop_coefficient_1": null,
|
398
|
+
"pthp_cop_coefficient_2": null,
|
399
|
+
"off_mode_power": null,
|
400
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
401
|
+
},
|
402
|
+
{
|
403
|
+
"equipment_type": "Heat Pumps",
|
404
|
+
"cooling_type": "GroundWaterSource",
|
405
|
+
"configuration": null,
|
406
|
+
"subcategory": null,
|
407
|
+
"application": null,
|
408
|
+
"rating_condition": null,
|
409
|
+
"electric_power_phase": null,
|
410
|
+
"region": null,
|
411
|
+
"minimum_capacity": 0,
|
412
|
+
"maximum_capacity": 134999.99,
|
413
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
414
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
415
|
+
"minimum_heating_seasonal_performance_factor": null,
|
416
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
417
|
+
"minimum_coefficient_of_performance_heating": 3.6,
|
418
|
+
"pthp_cop_coefficient_1": null,
|
419
|
+
"pthp_cop_coefficient_2": null,
|
420
|
+
"off_mode_power": null,
|
421
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
422
|
+
},
|
423
|
+
{
|
424
|
+
"equipment_type": "Heat Pumps",
|
425
|
+
"cooling_type": "GroundSource",
|
426
|
+
"configuration": null,
|
427
|
+
"subcategory": null,
|
428
|
+
"application": null,
|
429
|
+
"rating_condition": null,
|
430
|
+
"electric_power_phase": null,
|
431
|
+
"region": null,
|
432
|
+
"minimum_capacity": 0,
|
433
|
+
"maximum_capacity": 134999.99,
|
434
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
435
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
436
|
+
"minimum_heating_seasonal_performance_factor": null,
|
437
|
+
"minimum_heating_seasonal_performance_factor_2": null,
|
438
|
+
"minimum_coefficient_of_performance_heating": 3.1,
|
439
|
+
"pthp_cop_coefficient_1": null,
|
440
|
+
"pthp_cop_coefficient_2": null,
|
441
|
+
"off_mode_power": null,
|
442
|
+
"minimum_coefficient_of_performance_no_fan_heating": null
|
162
443
|
}
|
163
444
|
]
|
164
445
|
}
|