openstudio-standards 0.2.16 → 0.2.17.rc1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/standards/manage_OpenStudio_Standards.rb +31 -4
- data/lib/openstudio-standards/btap/geometry.rb +1 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +354 -2
- data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +79 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +3313 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +12 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +3 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +167 -93
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +2 -4
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +1 -0
- data/lib/openstudio-standards/refs/references.rb +3 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +279 -6
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +50 -2
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +4 -0
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.Construction.rb +185 -3
- data/lib/openstudio-standards/standards/Standards.Fan.rb +14 -6
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +1 -0
- data/lib/openstudio-standards/standards/Standards.Model.rb +1751 -383
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +130 -9
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +50 -3
- data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +44 -0
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +27 -0
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +543 -0
- data/lib/openstudio-standards/standards/Standards.Space.rb +665 -15
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +141 -4
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.Surface.rb +117 -0
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +197 -49
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +41 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model.rb +6 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +45 -45
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +45 -45
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +45 -45
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +9 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +45 -45
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json +45 -45
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json +45 -45
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.fans.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +45 -45
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +10 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +45 -45
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +10 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +792 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctParallelPIUReheat.rb +10 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat.rb +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater.rb +91 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +84 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +145 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +106 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +71 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +194 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +120 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb +110 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Fan.rb +73 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat.rb +55 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +3045 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface.rb +187 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +450 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +106 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +666 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Surface.rb +54 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone.rb +168 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent.rb +132 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +239 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +176 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +25 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.boilers.json +52 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.chillers.json +112 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.climate_zone_sets.json +210 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.construction_properties.json +10384 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.construction_sets.json +133 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.furnaces.json +43 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps.json +119 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps_heating.json +130 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_rejection.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.lpd_space_type.json +568 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.motors.json +264 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_baseline_hvac.json +439 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_constructions.json +685 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_economizers.json +213 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_ext_ltg.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_heat_type.json +136 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_hvac_bldg_type.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_interior_lighting.json +1837 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_swh_bldg_type.json +184 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.prm_wwr_bldg_type.json +84 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.unitary_acs.json +148 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.water_heaters.json +157 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.climate_zone_sets.json +210 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +18329 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +340 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.materials.json +49924 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_building_rotation_exception.md +44 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/check_pump_power_and_control.md +71 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/dcv.md +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/dcv_implementation.png +0 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/elevators.md +14 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/exhaust_air_energy_recovery.md +36 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/f_c_factors.md +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/fan_power_credits.md +15 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/preheat_coil.md +59 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/pump_power_control.md +46 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/return_air_type.md +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_baseline_wwr.md +191 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_hw_and_chw_supply_water_temp_reset_control.md +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_num_boilers_chillers_towers.md +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_plug_load_measures.md +80 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_space_lpd.md +73 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/unenclosed_and_unconditioned_spaces.md +11 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/unmet_load_hours.md +20 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/vav_parallel_piu_terminals_fan_control.md +23 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/vav_terminals_min_flow_setpoint.md +21 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_airloop_hvac.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_airloop_hvac_doas.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_building.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_design_specification_outdoor_air.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_electric_equipment.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_exterior_lights.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_gas_equipment.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_lights.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_space.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_spacetype.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_thermal_zone.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_wateruse_connections.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_wateruse_equipment.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_wateruse_equipment_definition.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_zone_hvac.csv +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_zone_infiltration.csv +1 -0
- data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +12 -0
- data/lib/openstudio-standards/standards/deer/data/deer.fans.json +12 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +1 -1
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +1 -1
- data/lib/openstudio-standards/standards/necb/ECMS/data/unitary_acs.json +24 -11
- data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +13 -15
- data/lib/openstudio-standards/standards/necb/NECB2011/data/province_map.json +17 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +6 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +3 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +2 -3
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +33 -924
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +135 -29
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +16 -4
- data/lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv +40 -42
- data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +1 -1
- data/lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json +89 -89
- data/lib/openstudio-standards/utilities/array.rb +11 -0
- data/lib/openstudio-standards/utilities/logging.rb +48 -0
- data/lib/openstudio-standards/utilities/object_info.rb +20 -0
- data/lib/openstudio-standards/utilities/schedule_translator.rb +348 -0
- data/lib/openstudio-standards/utilities/sqlfile.rb +68 -0
- data/lib/openstudio-standards/version.rb +2 -2
- data/lib/openstudio-standards/weather/Weather.Model.rb +42 -55
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +1 -1
- data/lib/openstudio-standards.rb +35 -1
- metadata +111 -6
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1_28Jan2022.xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1_28_Jan2022_2.xlsx +0 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +0 -143
@@ -0,0 +1,176 @@
|
|
1
|
+
class ASHRAE901PRM2019 < ASHRAE901PRM
|
2
|
+
# @!group Model
|
3
|
+
|
4
|
+
# Determine if there is a need for a proposed model sizing run.
|
5
|
+
# A typical application of such sizing run is to determine space
|
6
|
+
# conditioning type.
|
7
|
+
#
|
8
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
9
|
+
#
|
10
|
+
# @return [Boolean] Returns true if a sizing run is required
|
11
|
+
def model_create_prm_baseline_building_requires_proposed_model_sizing_run(model)
|
12
|
+
return true
|
13
|
+
end
|
14
|
+
|
15
|
+
# Determines the area of the building above which point
|
16
|
+
# the non-dominant area type gets it's own HVAC system type.
|
17
|
+
# @return [Double] the minimum area (m^2)
|
18
|
+
def model_prm_baseline_system_group_minimum_area(model, custom)
|
19
|
+
exception_min_area_ft2 = 20_000
|
20
|
+
# Customization - Xcel EDA Program Manual 2014
|
21
|
+
# 3.2.1 Mechanical System Selection ii
|
22
|
+
if custom == 'Xcel Energy CO EDA'
|
23
|
+
exception_min_area_ft2 = 5000
|
24
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.Model', "Customization; per Xcel EDA Program Manual 2014 3.2.1 Mechanical System Selection ii, minimum area for non-predominant conditions reduced to #{exception_min_area_ft2} ft2.")
|
25
|
+
end
|
26
|
+
exception_min_area_m2 = OpenStudio.convert(exception_min_area_ft2, 'ft^2', 'm^2').get
|
27
|
+
return exception_min_area_m2
|
28
|
+
end
|
29
|
+
|
30
|
+
# Determines which system number is used
|
31
|
+
# for the baseline system.
|
32
|
+
# @return [String] the system number: 1_or_2, 3_or_4,
|
33
|
+
# 5_or_6, 7_or_8, 9_or_10
|
34
|
+
def model_prm_baseline_system_number(model, climate_zone, area_type, fuel_type, area_ft2, num_stories, custom)
|
35
|
+
sys_num = nil
|
36
|
+
|
37
|
+
# Customization - Xcel EDA Program Manual 2014
|
38
|
+
# Table 3.2.2 Baseline HVAC System Types
|
39
|
+
if custom == 'Xcel Energy CO EDA'
|
40
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.Model', 'Custom; per Xcel EDA Program Manual 2014 Table 3.2.2 Baseline HVAC System Types, the 90.1-2010 lookup for HVAC system types shall be used.')
|
41
|
+
|
42
|
+
# Set the area limit
|
43
|
+
limit_ft2 = 25_000
|
44
|
+
|
45
|
+
case area_type
|
46
|
+
when 'residential'
|
47
|
+
sys_num = '1_or_2'
|
48
|
+
when 'nonresidential'
|
49
|
+
# nonresidential and 3 floors or less and <25,000 ft2
|
50
|
+
if num_stories <= 3 && area_ft2 < limit_ft2
|
51
|
+
sys_num = '3_or_4'
|
52
|
+
# nonresidential and 4 or 5 floors or 5 floors or less and 25,000 ft2 to 150,000 ft2
|
53
|
+
elsif ((num_stories == 4 || num_stories == 5) && area_ft2 < limit_ft2) || (num_stories <= 5 && (area_ft2 >= limit_ft2 && area_ft2 <= 150_000))
|
54
|
+
sys_num = '5_or_6'
|
55
|
+
# nonresidential and more than 5 floors or >150,000 ft2
|
56
|
+
elsif num_stories >= 5 || area_ft2 > 150_000
|
57
|
+
sys_num = '7_or_8'
|
58
|
+
end
|
59
|
+
when 'heatedonly'
|
60
|
+
sys_num = '9_or_10'
|
61
|
+
when 'retail'
|
62
|
+
# Should only be hit by Xcel EDA
|
63
|
+
sys_num = '3_or_4'
|
64
|
+
end
|
65
|
+
|
66
|
+
else
|
67
|
+
|
68
|
+
# Set the area limit
|
69
|
+
limit_ft2 = 25_000
|
70
|
+
|
71
|
+
case area_type
|
72
|
+
when 'residential'
|
73
|
+
sys_num = '1_or_2'
|
74
|
+
when 'nonresidential'
|
75
|
+
# nonresidential and 3 floors or less and <25,000 ft2
|
76
|
+
if num_stories <= 3 && area_ft2 < limit_ft2
|
77
|
+
sys_num = '3_or_4'
|
78
|
+
# nonresidential and 4 or 5 floors or 5 floors or less and 25,000 ft2 to 150,000 ft2
|
79
|
+
elsif ((num_stories == 4 || num_stories == 5) && area_ft2 < limit_ft2) || (num_stories <= 5 && (area_ft2 >= limit_ft2 && area_ft2 <= 150_000))
|
80
|
+
sys_num = '5_or_6'
|
81
|
+
# nonresidential and more than 5 floors or >150,000 ft2
|
82
|
+
elsif num_stories >= 5 || area_ft2 > 150_000
|
83
|
+
sys_num = '7_or_8'
|
84
|
+
end
|
85
|
+
when 'heatedonly'
|
86
|
+
sys_num = '9_or_10'
|
87
|
+
when 'retail'
|
88
|
+
sys_num = '3_or_4'
|
89
|
+
end
|
90
|
+
|
91
|
+
end
|
92
|
+
|
93
|
+
return sys_num
|
94
|
+
end
|
95
|
+
|
96
|
+
# Change the fuel type based on climate zone, depending on the standard.
|
97
|
+
# For 90.1-2013, fuel type is based on climate zone, not the proposed model.
|
98
|
+
# @return [String] the revised fuel type
|
99
|
+
def model_prm_baseline_system_change_fuel_type(model, fuel_type, climate_zone, custom = nil)
|
100
|
+
if custom == 'Xcel Energy CO EDA'
|
101
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.Model', 'Custom; per Xcel EDA Program Manual 2014 Table 3.2.2 Baseline HVAC System Types, the 90.1-2010 rules for heating fuel type (based on proposed model) rules apply.')
|
102
|
+
return fuel_type
|
103
|
+
end
|
104
|
+
|
105
|
+
# For 90.1-2013 the fuel type is determined based on climate zone.
|
106
|
+
# Don't change the fuel if it purchased heating or cooling.
|
107
|
+
if fuel_type == 'electric' || fuel_type == 'fossil'
|
108
|
+
case climate_zone
|
109
|
+
when 'ASHRAE 169-2006-1A',
|
110
|
+
'ASHRAE 169-2006-2A',
|
111
|
+
'ASHRAE 169-2006-3A',
|
112
|
+
'ASHRAE 169-2013-1A',
|
113
|
+
'ASHRAE 169-2013-2A',
|
114
|
+
'ASHRAE 169-2013-3A'
|
115
|
+
fuel_type = 'electric'
|
116
|
+
else
|
117
|
+
fuel_type = 'fossil'
|
118
|
+
end
|
119
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.Model', "Heating fuel is #{fuel_type} for 90.1-2013, climate zone #{climate_zone}. This is independent of the heating fuel type in the proposed building, per G3.1.1-3. This is different than previous versions of 90.1.")
|
120
|
+
end
|
121
|
+
|
122
|
+
return fuel_type
|
123
|
+
end
|
124
|
+
|
125
|
+
# Determines the fan type used by VAV_Reheat and VAV_PFP_Boxes systems.
|
126
|
+
# Variable speed fan for 90.1-2013
|
127
|
+
# @return [String] the fan type: TwoSpeed Fan, Variable Speed Fan
|
128
|
+
def model_baseline_system_vav_fan_type(model)
|
129
|
+
fan_type = 'Variable Speed Fan'
|
130
|
+
return fan_type
|
131
|
+
end
|
132
|
+
|
133
|
+
# Determines the skylight to roof ratio limit for a given standard
|
134
|
+
# 3% for 90.1-PRM-2019
|
135
|
+
# @return [Double] the skylight to roof ratio, as a percent: 5.0 = 5%
|
136
|
+
def model_prm_skylight_to_roof_ratio_limit(model)
|
137
|
+
srr_lim = 3.0
|
138
|
+
return srr_lim
|
139
|
+
end
|
140
|
+
|
141
|
+
# Determine the surface range of a baseline model.
|
142
|
+
# The method calculates the window to wall ratio (assuming all spaces are conditioned)
|
143
|
+
# and select the range based on the calculated window to wall ratio
|
144
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
145
|
+
# @param wwr_parameter [Hash] parameters to choose min and max percent of surfaces,
|
146
|
+
# could be different set in different standard
|
147
|
+
def model_get_percent_of_surface_range(model, wwr_parameter)
|
148
|
+
wwr_range = { 'minimum_percent_of_surface' => nil, 'maximum_percent_of_surface' => nil }
|
149
|
+
intended_surface_type = wwr_parameter['intended_surface_type']
|
150
|
+
if intended_surface_type == 'ExteriorWindow' || intended_surface_type == 'GlassDoor'
|
151
|
+
if wwr_parameter.key?('wwr_building_type')
|
152
|
+
wwr_building_type = wwr_parameter['wwr_building_type']
|
153
|
+
wwr_info = wwr_parameter['wwr_info']
|
154
|
+
if wwr_info[wwr_building_type] <= 10
|
155
|
+
wwr_range['minimum_percent_of_surface'] = 0
|
156
|
+
wwr_range['maximum_percent_of_surface'] = 10
|
157
|
+
elsif wwr_info[wwr_building_type] <= 20
|
158
|
+
wwr_range['minimum_percent_of_surface'] = 10.1
|
159
|
+
wwr_range['maximum_percent_of_surface'] = 20
|
160
|
+
elsif wwr_info[wwr_building_type] <= 30
|
161
|
+
wwr_range['minimum_percent_of_surface'] = 20.1
|
162
|
+
wwr_range['maximum_percent_of_surface'] = 30
|
163
|
+
elsif wwr_info[wwr_building_type] <= 40
|
164
|
+
wwr_range['minimum_percent_of_surface'] = 30.1
|
165
|
+
wwr_range['maximum_percent_of_surface'] = 40
|
166
|
+
else
|
167
|
+
wwr_range['minimum_percent_of_surface'] = nil
|
168
|
+
wwr_range['maximum_percent_of_surface'] = nil
|
169
|
+
end
|
170
|
+
else
|
171
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.model.Model', 'No wwr_building_type found for ExteriorWindow or GlassDoor')
|
172
|
+
end
|
173
|
+
end
|
174
|
+
return wwr_range
|
175
|
+
end
|
176
|
+
end
|
data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb
ADDED
@@ -0,0 +1,25 @@
|
|
1
|
+
# This class holds methods that apply ASHRAE 90.1-2013
|
2
|
+
# to a given model.
|
3
|
+
# @ref [References::ASHRAE9012013]
|
4
|
+
class ASHRAE901PRM2019 < ASHRAE901PRM
|
5
|
+
register_standard '90.1-PRM-2019'
|
6
|
+
attr_reader :template
|
7
|
+
|
8
|
+
def initialize
|
9
|
+
@template = '90.1-PRM-2019'
|
10
|
+
load_standards_database
|
11
|
+
end
|
12
|
+
|
13
|
+
def load_standards_database(data_directories = [])
|
14
|
+
super([__dir__] + data_directories)
|
15
|
+
end
|
16
|
+
|
17
|
+
# Determine the base infiltration rate at 75 PA.
|
18
|
+
#
|
19
|
+
# @return [Double] the baseline infiltration rate, in cfm/ft^2
|
20
|
+
# defaults to no infiltration.
|
21
|
+
def space_infiltration_rate_75_pa
|
22
|
+
basic_infil_rate_cfm_per_ft2 = 1.0
|
23
|
+
return basic_infil_rate_cfm_per_ft2
|
24
|
+
end
|
25
|
+
end
|
@@ -0,0 +1,52 @@
|
|
1
|
+
{
|
2
|
+
"boilers": [
|
3
|
+
{
|
4
|
+
"template": "90.1-PRM-2019",
|
5
|
+
"fluid_type": "Hot Water",
|
6
|
+
"fuel_type": "Gas",
|
7
|
+
"condensing": null,
|
8
|
+
"condensing_control": null,
|
9
|
+
"minimum_capacity": 0.0,
|
10
|
+
"maximum_capacity": 299999.0,
|
11
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
12
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
13
|
+
"minimum_annual_fuel_utilization_efficiency": 0.8,
|
14
|
+
"minimum_thermal_efficiency": null,
|
15
|
+
"minimum_combustion_efficiency": null,
|
16
|
+
"efffplr": "Boiler with Minimum Turndown",
|
17
|
+
"notes": "From Table G3.5.6"
|
18
|
+
},
|
19
|
+
{
|
20
|
+
"template": "90.1-PRM-2019",
|
21
|
+
"fluid_type": "Hot Water",
|
22
|
+
"fuel_type": "Gas",
|
23
|
+
"condensing": null,
|
24
|
+
"condensing_control": null,
|
25
|
+
"minimum_capacity": 300000.0,
|
26
|
+
"maximum_capacity": 2500000.0,
|
27
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
28
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
29
|
+
"minimum_annual_fuel_utilization_efficiency": null,
|
30
|
+
"minimum_thermal_efficiency": 0.75,
|
31
|
+
"minimum_combustion_efficiency": null,
|
32
|
+
"efffplr": "Boiler with Minimum Turndown",
|
33
|
+
"notes": "From Table G3.5.6"
|
34
|
+
},
|
35
|
+
{
|
36
|
+
"template": "90.1-PRM-2019",
|
37
|
+
"fluid_type": "Hot Water",
|
38
|
+
"fuel_type": "Gas",
|
39
|
+
"condensing": null,
|
40
|
+
"condensing_control": null,
|
41
|
+
"minimum_capacity": 2500001.0,
|
42
|
+
"maximum_capacity": 9999999999.0,
|
43
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
44
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
45
|
+
"minimum_annual_fuel_utilization_efficiency": null,
|
46
|
+
"minimum_thermal_efficiency": null,
|
47
|
+
"minimum_combustion_efficiency": 0.8,
|
48
|
+
"efffplr": "Boiler with Minimum Turndown",
|
49
|
+
"notes": "From Table G3.5.6"
|
50
|
+
}
|
51
|
+
]
|
52
|
+
}
|
@@ -0,0 +1,112 @@
|
|
1
|
+
{
|
2
|
+
"chillers": [
|
3
|
+
{
|
4
|
+
"template": "90.1-PRM-2019",
|
5
|
+
"cooling_type": "WaterCooled",
|
6
|
+
"condenser_type": null,
|
7
|
+
"compressor_type": "Centrifugal",
|
8
|
+
"absorption_type": null,
|
9
|
+
"variable_speed_drive": null,
|
10
|
+
"minimum_capacity": 0.0,
|
11
|
+
"maximum_capacity": 149.99,
|
12
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
13
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
14
|
+
"minimum_full_load_efficiency": 0.703,
|
15
|
+
"minimum_integrated_part_load_value": 0.67,
|
16
|
+
"capft": null,
|
17
|
+
"eirft": null,
|
18
|
+
"eirfplr": null,
|
19
|
+
"notes": "Path A Efficiencies"
|
20
|
+
},
|
21
|
+
{
|
22
|
+
"template": "90.1-PRM-2019",
|
23
|
+
"cooling_type": "WaterCooled",
|
24
|
+
"condenser_type": null,
|
25
|
+
"compressor_type": "Centrifugal",
|
26
|
+
"absorption_type": null,
|
27
|
+
"variable_speed_drive": null,
|
28
|
+
"minimum_capacity": 150.0,
|
29
|
+
"maximum_capacity": 299.99,
|
30
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
31
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
32
|
+
"minimum_full_load_efficiency": 0.634,
|
33
|
+
"minimum_integrated_part_load_value": 0.596,
|
34
|
+
"capft": null,
|
35
|
+
"eirft": null,
|
36
|
+
"eirfplr": null,
|
37
|
+
"notes": "Path A Efficiencies"
|
38
|
+
},
|
39
|
+
{
|
40
|
+
"template": "90.1-PRM-2019",
|
41
|
+
"cooling_type": "WaterCooled",
|
42
|
+
"condenser_type": null,
|
43
|
+
"compressor_type": "Centrifugal",
|
44
|
+
"absorption_type": null,
|
45
|
+
"variable_speed_drive": null,
|
46
|
+
"minimum_capacity": 300.0,
|
47
|
+
"maximum_capacity": 9999.0,
|
48
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
49
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
50
|
+
"minimum_full_load_efficiency": 0.576,
|
51
|
+
"minimum_integrated_part_load_value": 0.549,
|
52
|
+
"capft": null,
|
53
|
+
"eirft": null,
|
54
|
+
"eirfplr": null,
|
55
|
+
"notes": "Path A Efficiencies"
|
56
|
+
},
|
57
|
+
{
|
58
|
+
"template": "90.1-PRM-2019",
|
59
|
+
"cooling_type": "WaterCooled",
|
60
|
+
"condenser_type": null,
|
61
|
+
"compressor_type": "Rotary Screw and Scroll",
|
62
|
+
"absorption_type": null,
|
63
|
+
"variable_speed_drive": null,
|
64
|
+
"minimum_capacity": 0.0,
|
65
|
+
"maximum_capacity": 149.99,
|
66
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
67
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
68
|
+
"minimum_full_load_efficiency": 0.79,
|
69
|
+
"minimum_integrated_part_load_value": 0.676,
|
70
|
+
"capft": null,
|
71
|
+
"eirft": null,
|
72
|
+
"eirfplr": null,
|
73
|
+
"notes": "Path A Efficiencies"
|
74
|
+
},
|
75
|
+
{
|
76
|
+
"template": "90.1-PRM-2019",
|
77
|
+
"cooling_type": "WaterCooled",
|
78
|
+
"condenser_type": null,
|
79
|
+
"compressor_type": "Rotary Screw and Scroll",
|
80
|
+
"absorption_type": null,
|
81
|
+
"variable_speed_drive": null,
|
82
|
+
"minimum_capacity": 150.0,
|
83
|
+
"maximum_capacity": 299.99,
|
84
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
85
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
86
|
+
"minimum_full_load_efficiency": 0.718,
|
87
|
+
"minimum_integrated_part_load_value": 0.629,
|
88
|
+
"capft": null,
|
89
|
+
"eirft": null,
|
90
|
+
"eirfplr": null,
|
91
|
+
"notes": "Path A Efficiencies"
|
92
|
+
},
|
93
|
+
{
|
94
|
+
"template": "90.1-PRM-2019",
|
95
|
+
"cooling_type": "WaterCooled",
|
96
|
+
"condenser_type": null,
|
97
|
+
"compressor_type": "Rotary Screw and Scroll",
|
98
|
+
"absorption_type": null,
|
99
|
+
"variable_speed_drive": null,
|
100
|
+
"minimum_capacity": 300.0,
|
101
|
+
"maximum_capacity": 9999.0,
|
102
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
103
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
104
|
+
"minimum_full_load_efficiency": 0.639,
|
105
|
+
"minimum_integrated_part_load_value": 0.572,
|
106
|
+
"capft": null,
|
107
|
+
"eirft": null,
|
108
|
+
"eirfplr": null,
|
109
|
+
"notes": "Path A Efficiencies"
|
110
|
+
}
|
111
|
+
]
|
112
|
+
}
|
@@ -0,0 +1,210 @@
|
|
1
|
+
{
|
2
|
+
"climate_zone_sets": [
|
3
|
+
{
|
4
|
+
"name": "ClimateZone 0",
|
5
|
+
"climate_zones": [
|
6
|
+
"ASHRAE 169-2006-0A",
|
7
|
+
"ASHRAE 169-2006-0B",
|
8
|
+
"ASHRAE 169-2013-0A",
|
9
|
+
"ASHRAE 169-2013-0B"
|
10
|
+
]
|
11
|
+
},
|
12
|
+
{
|
13
|
+
"name": "ClimateZone 0A",
|
14
|
+
"climate_zones": [
|
15
|
+
"ASHRAE 169-2006-0A",
|
16
|
+
"ASHRAE 169-2013-0A"
|
17
|
+
]
|
18
|
+
},
|
19
|
+
{
|
20
|
+
"name": "ClimateZone 0B",
|
21
|
+
"climate_zones": [
|
22
|
+
"ASHRAE 169-2006-0B",
|
23
|
+
"ASHRAE 169-2013-0B"
|
24
|
+
]
|
25
|
+
},
|
26
|
+
{
|
27
|
+
"name": "ClimateZone 1",
|
28
|
+
"climate_zones": [
|
29
|
+
"ASHRAE 169-2006-1A",
|
30
|
+
"ASHRAE 169-2006-1B",
|
31
|
+
"ASHRAE 169-2013-1A",
|
32
|
+
"ASHRAE 169-2013-1B"
|
33
|
+
]
|
34
|
+
},
|
35
|
+
{
|
36
|
+
"name": "ClimateZone 1A",
|
37
|
+
"climate_zones": [
|
38
|
+
"ASHRAE 169-2006-1A",
|
39
|
+
"ASHRAE 169-2013-1A"
|
40
|
+
]
|
41
|
+
},
|
42
|
+
{
|
43
|
+
"name": "ClimateZone 1B",
|
44
|
+
"climate_zones": [
|
45
|
+
"ASHRAE 169-2006-1B",
|
46
|
+
"ASHRAE 169-2013-1B"
|
47
|
+
]
|
48
|
+
},
|
49
|
+
{
|
50
|
+
"name": "ClimateZone 2",
|
51
|
+
"climate_zones": [
|
52
|
+
"ASHRAE 169-2006-2A",
|
53
|
+
"ASHRAE 169-2006-2B",
|
54
|
+
"ASHRAE 169-2013-2A",
|
55
|
+
"ASHRAE 169-2013-2B"
|
56
|
+
]
|
57
|
+
},
|
58
|
+
{
|
59
|
+
"name": "ClimateZone 2A",
|
60
|
+
"climate_zones": [
|
61
|
+
"ASHRAE 169-2006-2A",
|
62
|
+
"ASHRAE 169-2013-2A"
|
63
|
+
]
|
64
|
+
},
|
65
|
+
{
|
66
|
+
"name": "ClimateZone 2B",
|
67
|
+
"climate_zones": [
|
68
|
+
"ASHRAE 169-2006-2B",
|
69
|
+
"ASHRAE 169-2013-2B"
|
70
|
+
]
|
71
|
+
},
|
72
|
+
{
|
73
|
+
"name": "ClimateZone 3",
|
74
|
+
"climate_zones": [
|
75
|
+
"ASHRAE 169-2006-3A",
|
76
|
+
"ASHRAE 169-2006-3B",
|
77
|
+
"ASHRAE 169-2006-3C",
|
78
|
+
"ASHRAE 169-2013-3A",
|
79
|
+
"ASHRAE 169-2013-3B",
|
80
|
+
"ASHRAE 169-2013-3C"
|
81
|
+
]
|
82
|
+
},
|
83
|
+
{
|
84
|
+
"name": "ClimateZone 3A",
|
85
|
+
"climate_zones": [
|
86
|
+
"ASHRAE 169-2006-3A",
|
87
|
+
"ASHRAE 169-2013-3A"
|
88
|
+
]
|
89
|
+
},
|
90
|
+
{
|
91
|
+
"name": "ClimateZone 3B",
|
92
|
+
"climate_zones": [
|
93
|
+
"ASHRAE 169-2006-3B",
|
94
|
+
"ASHRAE 169-2013-3B"
|
95
|
+
]
|
96
|
+
},
|
97
|
+
{
|
98
|
+
"name": "ClimateZone 3C",
|
99
|
+
"climate_zones": [
|
100
|
+
"ASHRAE 169-2006-3C",
|
101
|
+
"ASHRAE 169-2013-3C"
|
102
|
+
]
|
103
|
+
},
|
104
|
+
{
|
105
|
+
"name": "ClimateZone 4",
|
106
|
+
"climate_zones": [
|
107
|
+
"ASHRAE 169-2006-4A",
|
108
|
+
"ASHRAE 169-2006-4B",
|
109
|
+
"ASHRAE 169-2006-4C",
|
110
|
+
"ASHRAE 169-2013-4A",
|
111
|
+
"ASHRAE 169-2013-4B",
|
112
|
+
"ASHRAE 169-2013-4C"
|
113
|
+
]
|
114
|
+
},
|
115
|
+
{
|
116
|
+
"name": "ClimateZone 4A",
|
117
|
+
"climate_zones": [
|
118
|
+
"ASHRAE 169-2006-4A",
|
119
|
+
"ASHRAE 169-2013-4A"
|
120
|
+
]
|
121
|
+
},
|
122
|
+
{
|
123
|
+
"name": "ClimateZone 4B",
|
124
|
+
"climate_zones": [
|
125
|
+
"ASHRAE 169-2006-4B",
|
126
|
+
"ASHRAE 169-2013-4B"
|
127
|
+
]
|
128
|
+
},
|
129
|
+
{
|
130
|
+
"name": "ClimateZone 4C",
|
131
|
+
"climate_zones": [
|
132
|
+
"ASHRAE 169-2006-4C",
|
133
|
+
"ASHRAE 169-2013-4C"
|
134
|
+
]
|
135
|
+
},
|
136
|
+
{
|
137
|
+
"name": "ClimateZone 5",
|
138
|
+
"climate_zones": [
|
139
|
+
"ASHRAE 169-2006-5A",
|
140
|
+
"ASHRAE 169-2006-5B",
|
141
|
+
"ASHRAE 169-2006-5C",
|
142
|
+
"ASHRAE 169-2013-5A",
|
143
|
+
"ASHRAE 169-2013-5B",
|
144
|
+
"ASHRAE 169-2013-5C"
|
145
|
+
]
|
146
|
+
},
|
147
|
+
{
|
148
|
+
"name": "ClimateZone 5A",
|
149
|
+
"climate_zones": [
|
150
|
+
"ASHRAE 169-2006-5A",
|
151
|
+
"ASHRAE 169-2013-5A"
|
152
|
+
]
|
153
|
+
},
|
154
|
+
{
|
155
|
+
"name": "ClimateZone 5B",
|
156
|
+
"climate_zones": [
|
157
|
+
"ASHRAE 169-2006-5B",
|
158
|
+
"ASHRAE 169-2013-5B"
|
159
|
+
]
|
160
|
+
},
|
161
|
+
{
|
162
|
+
"name": "ClimateZone 5C",
|
163
|
+
"climate_zones": [
|
164
|
+
"ASHRAE 169-2006-5C",
|
165
|
+
"ASHRAE 169-2013-5C"
|
166
|
+
]
|
167
|
+
},
|
168
|
+
{
|
169
|
+
"name": "ClimateZone 6",
|
170
|
+
"climate_zones": [
|
171
|
+
"ASHRAE 169-2006-6A",
|
172
|
+
"ASHRAE 169-2006-6B",
|
173
|
+
"ASHRAE 169-2013-6A",
|
174
|
+
"ASHRAE 169-2013-6B"
|
175
|
+
]
|
176
|
+
},
|
177
|
+
{
|
178
|
+
"name": "ClimateZone 6A",
|
179
|
+
"climate_zones": [
|
180
|
+
"ASHRAE 169-2006-6A",
|
181
|
+
"ASHRAE 169-2013-6A"
|
182
|
+
]
|
183
|
+
},
|
184
|
+
{
|
185
|
+
"name": "ClimateZone 6B",
|
186
|
+
"climate_zones": [
|
187
|
+
"ASHRAE 169-2006-6B",
|
188
|
+
"ASHRAE 169-2013-6B"
|
189
|
+
]
|
190
|
+
},
|
191
|
+
{
|
192
|
+
"name": "ClimateZone 7",
|
193
|
+
"climate_zones": [
|
194
|
+
"ASHRAE 169-2006-7A",
|
195
|
+
"ASHRAE 169-2006-7B",
|
196
|
+
"ASHRAE 169-2013-7A",
|
197
|
+
"ASHRAE 169-2013-7B"
|
198
|
+
]
|
199
|
+
},
|
200
|
+
{
|
201
|
+
"name": "ClimateZone 8",
|
202
|
+
"climate_zones": [
|
203
|
+
"ASHRAE 169-2006-8A",
|
204
|
+
"ASHRAE 169-2006-8B",
|
205
|
+
"ASHRAE 169-2013-8A",
|
206
|
+
"ASHRAE 169-2013-8B"
|
207
|
+
]
|
208
|
+
}
|
209
|
+
]
|
210
|
+
}
|