openstudio-common-measures 0.4.0 → 0.6.1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/.gitignore +1 -0
- data/.rubocop.yml +3 -1
- data/CHANGELOG.md +25 -0
- data/README.md +21 -2
- data/doc_templates/copyright_erb.txt +1 -1
- data/lib/measures/AddCostPerFloorAreaUnusedToLights/measure.xml +2 -8
- data/lib/measures/AddCostToSupplySideHVACComponentByAirLoop/measure.xml +9 -3
- data/lib/measures/AddSimplePvToShadingSurfacesByType/measure.xml +2 -2
- data/lib/measures/RemoveUnusedDefaultProfiles/measure.xml +2 -2
- data/lib/measures/ReportModelChanges/measure.xml +2 -2
- data/lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.xml +4 -4
- data/lib/measures/SetCOPforTwoSpeedDXCoolingUnits/measure.xml +4 -4
- data/lib/measures/SetGasBurnerEfficiency/measure.xml +4 -4
- data/lib/measures/ShiftScheduleProfileTime/measure.xml +4 -4
- data/lib/measures/SwapLightsDefinition/measure.xml +3 -5
- data/lib/measures/add_ems_emissions_reporting/LICENSE.MD.txt +15 -0
- data/lib/measures/add_ems_emissions_reporting/LICENSE.md +27 -0
- data/lib/measures/add_ems_emissions_reporting/README.md +17 -0
- data/lib/measures/add_ems_emissions_reporting/measure.rb +474 -0
- data/lib/measures/add_ems_emissions_reporting/measure.xml +599 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_annual_co2e.csv +17 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2020.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2022.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2024.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2026.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2028.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2030.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2032.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2034.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2036.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2038.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2040.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2042.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2044.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2046.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2048.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2050.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/historical_annual_co2e.csv +9 -0
- data/lib/measures/add_ems_emissions_reporting/resources/historical_hourly_co2e_2019.csv +8761 -0
- data/lib/measures/add_ev_load/measure.rb +51 -8
- data/lib/measures/add_ev_load/measure.xml +23 -5
- data/lib/measures/envelope_and_internal_load_breakdown/measure.xml +3 -3
- data/lib/measures/envelope_and_internal_load_breakdown/resources/report.html.erb +6 -1
- data/lib/measures/example_report/measure.xml +3 -3
- data/lib/measures/example_report/resources/report.html.erb +6 -1
- data/lib/measures/generic_qaqc/README.md +19 -4
- data/lib/measures/generic_qaqc/README.md.erb +7 -1
- data/lib/measures/generic_qaqc/docs/generic_qaqc_detailed.jpg +0 -0
- data/lib/measures/generic_qaqc/docs/generic_qaqc_summary.jpg +0 -0
- data/lib/measures/generic_qaqc/measure.rb +34 -29
- data/lib/measures/generic_qaqc/measure.xml +181 -82
- data/lib/measures/generic_qaqc/resources/check_cond_zns.rb +3 -1
- data/lib/measures/generic_qaqc/resources/check_domestic_hot_water.rb +13 -8
- data/lib/measures/generic_qaqc/resources/check_envelope_conductance.rb +330 -231
- data/lib/measures/generic_qaqc/resources/check_eui_by_end_use.rb +59 -20
- data/lib/measures/generic_qaqc/resources/check_eui_reasonableness.rb +58 -20
- data/lib/measures/generic_qaqc/resources/check_internal_loads.rb +57 -56
- data/lib/measures/generic_qaqc/resources/check_mech_sys_capacity.rb +4 -1
- data/lib/measures/generic_qaqc/resources/check_mech_sys_efficiency.rb +27 -22
- data/lib/measures/generic_qaqc/resources/check_mech_sys_part_load_eff.rb +4 -1
- data/lib/measures/generic_qaqc/resources/check_mech_sys_type.rb +3 -3
- data/lib/measures/generic_qaqc/resources/check_schedules.rb +65 -101
- data/lib/measures/generic_qaqc/resources/check_simultaneous_heating_and_cooling.rb +3 -1
- data/lib/measures/generic_qaqc/resources/check_supply_air_and_thermostat_temp_difference.rb +3 -1
- data/lib/measures/generic_qaqc/resources/os_lib_reporting_qaqc.rb +49 -15
- data/lib/measures/generic_qaqc/resources/report.html.erb +6 -1
- data/lib/measures/hvac_psychrometric_chart/measure.xml +4 -3
- data/lib/measures/hvac_psychrometric_chart/resources/report.html.erb +6 -1
- data/lib/measures/openstudio_results/measure.xml +3 -3
- data/lib/measures/openstudio_results/resources/report.html.erb +6 -1
- data/lib/measures/set_run_period/measure.xml +2 -2
- data/lib/measures/view_data/measure.xml +9 -9
- data/lib/measures/view_data/resources/report.html.in +1336 -973
- data/lib/measures/view_data/resources/va3c.rb +1 -0
- data/lib/measures/view_model/measure.xml +33 -64
- data/lib/measures/view_model/resources/report.html.in +1339 -976
- data/lib/measures/view_model/resources/va3c.rb +1 -0
- data/lib/openstudio/common_measures/version.rb +1 -1
- data/openstudio-common-measures.gemspec +2 -2
- metadata +33 -7
checksums.yaml
CHANGED
@@ -1,7 +1,7 @@
|
|
1
1
|
---
|
2
2
|
SHA256:
|
3
|
-
metadata.gz:
|
4
|
-
data.tar.gz:
|
3
|
+
metadata.gz: 72f5781d905e2c6aed62ded29659058d7fbc5d52a1a33a8e440b44e4b522a3be
|
4
|
+
data.tar.gz: 19a23d3e3bb95f2470a699808b5f26ee4524d6192fe12eb2cd4dddf167274f35
|
5
5
|
SHA512:
|
6
|
-
metadata.gz:
|
7
|
-
data.tar.gz:
|
6
|
+
metadata.gz: 022bbbcc90db51554e035e0d5f5a0705003ae74216ea897d35aa35b095767e2064c6d543065cae72b2b71bd7ec6c458bf191be44ecdee6a9fd5634fab9a2a86d
|
7
|
+
data.tar.gz: 35545aec9130ec071f7f89aaebd3bb3100dff75d2d0b18ef183c267b08b47371ccf2840a9b57ce8c9eeec7dfd4d6fc90022a2245a0e748a08a5d98778598189f
|
data/.gitignore
CHANGED
data/.rubocop.yml
CHANGED
data/CHANGELOG.md
CHANGED
@@ -1,5 +1,30 @@
|
|
1
1
|
# OpenStudio Common Measures Gem
|
2
2
|
|
3
|
+
## Version 0.6.1
|
4
|
+
|
5
|
+
- Fixed [#107]( https://github.com/NREL/openstudio-common-measures-gem/pull/107 ), Added natural gas emissions calculations
|
6
|
+
- Fixed [#109]( https://github.com/NREL/openstudio-common-measures-gem/pull/109 ), changed variable names to include Electricity and removed "_Var"
|
7
|
+
|
8
|
+
|
9
|
+
## Version 0.6.0
|
10
|
+
|
11
|
+
* Support for OpenStudio 3.4 (upgrade to standards gem 0.2.16, no extension gem upgrade)
|
12
|
+
* Fixed [#53]( https://github.com/NREL/openstudio-common-measures-gem/issues/53 ), View Model and View Data measures are missing rendering color for Foundation
|
13
|
+
* Fixed [#90]( https://github.com/NREL/openstudio-common-measures-gem/pull/90 ), Adjacency Checker
|
14
|
+
* Fixed [#93]( https://github.com/NREL/openstudio-common-measures-gem/pull/93 ), Qaqc issue 79
|
15
|
+
* Fixed [#94]( https://github.com/NREL/openstudio-common-measures-gem/pull/94 ), remove unique output variable names
|
16
|
+
* Fixed [#95]( https://github.com/NREL/openstudio-common-measures-gem/pull/95 ), Qaqc issue 79
|
17
|
+
* Fixed [#96]( https://github.com/NREL/openstudio-common-measures-gem/pull/96 ), Add additional argument to add_ev_load measure
|
18
|
+
* Fixed [#97]( https://github.com/NREL/openstudio-common-measures-gem/pull/97 ), Add color for Foundation boundary condition
|
19
|
+
|
20
|
+
## Version 0.5.0
|
21
|
+
|
22
|
+
* Support for OpenStudio 3.3 (upgrade to extension gem 0.5.1 and standards gem 0.2.15)
|
23
|
+
* Fixed [#80]( https://github.com/NREL/openstudio-common-measures-gem/pull/80 ), Custom emissions reporting measure
|
24
|
+
* Fixed [#82]( https://github.com/NREL/openstudio-common-measures-gem/pull/82 ), adding compatibility matrix and contribution policy
|
25
|
+
* Fixed [#84]( https://github.com/NREL/openstudio-common-measures-gem/pull/84 ), Add latest CO2 CSVs from LBNL
|
26
|
+
* Adding surface search to view model and view data commited by macumber
|
27
|
+
|
3
28
|
## Version 0.4.0
|
4
29
|
|
5
30
|
* Support Ruby ~> 2.7
|
data/README.md
CHANGED
@@ -34,10 +34,29 @@ bundle exec rake openstudio:test_with_openstudio
|
|
34
34
|
|
35
35
|
- [ ] Update measures to follow coding standards
|
36
36
|
|
37
|
+
# Compatibility Matrix
|
38
|
+
|
39
|
+
|OpenStudio Common Measures Gem|OpenStudio|Ruby|
|
40
|
+
|:--------------:|:----------:|:--------:|
|
41
|
+
| 0.6.0 - 0.6.1 | 3.4 | 2.7 |
|
42
|
+
| 0.5.0 | 3.3 | 2.7 |
|
43
|
+
| 0.4.0 - 0,4.2 | 3.2 | 2.7 |
|
44
|
+
| 0.3.0 - 0.3.2 | 3.1 | 2.5 |
|
45
|
+
| 0.2.0 - 0.2.1 | 3.0 | 2.5 |
|
46
|
+
| 0.1.2 and below | 2.9 and below | 2.2.4 |
|
47
|
+
|
48
|
+
# Contributing
|
49
|
+
|
50
|
+
Please review the [OpenStudio Contribution Policy](https://openstudio.net/openstudio-contribution-policy) if you would like to contribute code to this gem.
|
51
|
+
|
37
52
|
# Releasing
|
38
53
|
|
39
|
-
* Update CHANGELOG.md
|
40
|
-
* Run `rake rubocop:auto_correct`
|
54
|
+
* Update `CHANGELOG.md` with the `rake openstudio:change_log` command
|
55
|
+
* Run `rake openstudio:rubocop:auto_correct`
|
56
|
+
* Run `rake openstudio:update_copyright`
|
57
|
+
* Run `rake openstudio:update_measures` (this has to be done last since prior tasks alter measure files)
|
58
|
+
* Update version in `readme.md`
|
59
|
+
* Update version in `openstudio-common_measures.gemspec`
|
41
60
|
* Update version in `/lib/openstudio/common_measures/version.rb`
|
42
61
|
* Create PR to master, after tests and reviews complete, then merge
|
43
62
|
* Locally - from the master branch, run `rake release`
|
@@ -1,6 +1,6 @@
|
|
1
1
|
<%
|
2
2
|
# *******************************************************************************
|
3
|
-
# OpenStudio(R), Copyright (c) 2008-
|
3
|
+
# OpenStudio(R), Copyright (c) 2008-2022, Alliance for Sustainable Energy, LLC.
|
4
4
|
# All rights reserved.
|
5
5
|
# Redistribution and use in source and binary forms, with or without
|
6
6
|
# modification, are permitted provided that the following conditions are met:
|
@@ -3,8 +3,8 @@
|
|
3
3
|
<schema_version>3.0</schema_version>
|
4
4
|
<name>add_cost_per_floor_area_to_unused_lights</name>
|
5
5
|
<uid>a5f5ddcf-48bb-413a-a712-0ee22f0b40a4</uid>
|
6
|
-
<version_id>
|
7
|
-
<version_modified>
|
6
|
+
<version_id>b381ec85-c37d-45b4-87bf-083af1209520</version_id>
|
7
|
+
<version_modified>20220506T153448Z</version_modified>
|
8
8
|
<xml_checksum>35DA4ED3</xml_checksum>
|
9
9
|
<class_name>AddCostPerFloorAreaToUnusedLights</class_name>
|
10
10
|
<display_name>Add Cost per Floor Area to Unused Lights</display_name>
|
@@ -137,12 +137,6 @@
|
|
137
137
|
</attribute>
|
138
138
|
</attributes>
|
139
139
|
<files>
|
140
|
-
<file>
|
141
|
-
<filename>resultsviewer.log</filename>
|
142
|
-
<filetype>log</filetype>
|
143
|
-
<usage_type>test</usage_type>
|
144
|
-
<checksum>00000000</checksum>
|
145
|
-
</file>
|
146
140
|
<file>
|
147
141
|
<filename>0416_NetArea_b.osm</filename>
|
148
142
|
<filetype>osm</filetype>
|
@@ -3,8 +3,8 @@
|
|
3
3
|
<schema_version>3.0</schema_version>
|
4
4
|
<name>add_cost_to_supply_side_hvac_component_by_air_loop</name>
|
5
5
|
<uid>a667a52f-aa04-4997-9292-c81671d75f84</uid>
|
6
|
-
<version_id>
|
7
|
-
<version_modified>
|
6
|
+
<version_id>edf06a2f-c8ae-4f6e-9f1e-a436e5e50863</version_id>
|
7
|
+
<version_modified>20220506T153447Z</version_modified>
|
8
8
|
<xml_checksum>35DA4ED3</xml_checksum>
|
9
9
|
<class_name>AddCostToSupplySideHVACComponentByAirLoop</class_name>
|
10
10
|
<display_name>Add Cost to Supply Side HVAC Component by Air Loop</display_name>
|
@@ -80,7 +80,7 @@
|
|
80
80
|
<model_dependent>false</model_dependent>
|
81
81
|
<choices>
|
82
82
|
<choice>
|
83
|
-
<value>{
|
83
|
+
<value>{e4edb35e-c955-4578-8731-128019ff33b6}</value>
|
84
84
|
<display_name>*All Air Loops*</display_name>
|
85
85
|
</choice>
|
86
86
|
</choices>
|
@@ -245,5 +245,11 @@
|
|
245
245
|
<usage_type>license</usage_type>
|
246
246
|
<checksum>A21A3ED2</checksum>
|
247
247
|
</file>
|
248
|
+
<file>
|
249
|
+
<filename>HVACComponentBasic/files/USA_CO_Golden-NREL.724666_TMY3.epw</filename>
|
250
|
+
<filetype>epw</filetype>
|
251
|
+
<usage_type>test</usage_type>
|
252
|
+
<checksum>BDF687C1</checksum>
|
253
|
+
</file>
|
248
254
|
</files>
|
249
255
|
</measure>
|
@@ -3,8 +3,8 @@
|
|
3
3
|
<schema_version>3.0</schema_version>
|
4
4
|
<name>add_simple_pv_to_shading_surfaces_by_type</name>
|
5
5
|
<uid>27627c16-75d4-4fc3-add9-2d7d538c0130</uid>
|
6
|
-
<version_id>
|
7
|
-
<version_modified>
|
6
|
+
<version_id>316e40e8-ec27-4288-92d8-b8bf33914860</version_id>
|
7
|
+
<version_modified>20220506T153447Z</version_modified>
|
8
8
|
<xml_checksum>92C8C204</xml_checksum>
|
9
9
|
<class_name>AddSimplePvToShadingSurfacesByType</class_name>
|
10
10
|
<display_name>Add Simple PV to Specified Shading Surfaces</display_name>
|
@@ -3,8 +3,8 @@
|
|
3
3
|
<schema_version>3.0</schema_version>
|
4
4
|
<name>remove_unused_default_profiles</name>
|
5
5
|
<uid>8abcdf38-c391-465a-8fb8-b243aa4f0b06</uid>
|
6
|
-
<version_id>
|
7
|
-
<version_modified>
|
6
|
+
<version_id>8492641b-96f2-4bc3-ba82-637794e6b015</version_id>
|
7
|
+
<version_modified>20220506T153446Z</version_modified>
|
8
8
|
<xml_checksum>B6CD1F98</xml_checksum>
|
9
9
|
<class_name>RemoveUnusedDefaultProfiles</class_name>
|
10
10
|
<display_name>RemoveUnusedDefaultProfiles</display_name>
|
@@ -3,8 +3,8 @@
|
|
3
3
|
<schema_version>3.0</schema_version>
|
4
4
|
<name>report_model_changes</name>
|
5
5
|
<uid>6d66b426-908f-4528-9fe5-523b9d2f49c5</uid>
|
6
|
-
<version_id>
|
7
|
-
<version_modified>
|
6
|
+
<version_id>50c52c2b-b884-4689-8dc6-86755d399c6f</version_id>
|
7
|
+
<version_modified>20220622T165903Z</version_modified>
|
8
8
|
<xml_checksum>1E1F8B97</xml_checksum>
|
9
9
|
<class_name>ReportModelChanges</class_name>
|
10
10
|
<display_name>ReportModelChanges</display_name>
|
@@ -3,8 +3,8 @@
|
|
3
3
|
<schema_version>3.0</schema_version>
|
4
4
|
<name>set_co_pfor_single_speed_dx_cooling_units</name>
|
5
5
|
<uid>a4a7297e-8314-4df7-86b5-bec18cdd0a3a</uid>
|
6
|
-
<version_id>
|
7
|
-
<version_modified>
|
6
|
+
<version_id>a7f68115-1f19-4b95-9a8b-f315a6649eac</version_id>
|
7
|
+
<version_modified>20220506T153448Z</version_modified>
|
8
8
|
<xml_checksum>9E2537CD</xml_checksum>
|
9
9
|
<class_name>SetCOPforSingleSpeedDXCoolingUnits</class_name>
|
10
10
|
<display_name>Set COP for Single Speed DX Cooling Units</display_name>
|
@@ -17,10 +17,10 @@
|
|
17
17
|
<type>Choice</type>
|
18
18
|
<required>true</required>
|
19
19
|
<model_dependent>false</model_dependent>
|
20
|
-
<default_value>{
|
20
|
+
<default_value>{f382de5b-d797-4b8b-addc-35eeb4d28375}</default_value>
|
21
21
|
<choices>
|
22
22
|
<choice>
|
23
|
-
<value>{
|
23
|
+
<value>{f382de5b-d797-4b8b-addc-35eeb4d28375}</value>
|
24
24
|
<display_name>*All Air Loops*</display_name>
|
25
25
|
</choice>
|
26
26
|
</choices>
|
@@ -3,8 +3,8 @@
|
|
3
3
|
<schema_version>3.0</schema_version>
|
4
4
|
<name>set_co_pfor_two_speed_dx_cooling_units</name>
|
5
5
|
<uid>f5a8d60a-e60f-4097-99c3-28bfda3f29a3</uid>
|
6
|
-
<version_id>
|
7
|
-
<version_modified>
|
6
|
+
<version_id>1a6fc4b5-4c28-4ce7-8228-b8924c9312ed</version_id>
|
7
|
+
<version_modified>20220506T153442Z</version_modified>
|
8
8
|
<xml_checksum>9E2537CD</xml_checksum>
|
9
9
|
<class_name>SetCOPforTwoSpeedDXCoolingUnits</class_name>
|
10
10
|
<display_name>Set COP for Two Speed DX Cooling Units</display_name>
|
@@ -17,10 +17,10 @@
|
|
17
17
|
<type>Choice</type>
|
18
18
|
<required>true</required>
|
19
19
|
<model_dependent>false</model_dependent>
|
20
|
-
<default_value>{
|
20
|
+
<default_value>{fca41611-7e8e-483f-b9fd-e411fe241a81}</default_value>
|
21
21
|
<choices>
|
22
22
|
<choice>
|
23
|
-
<value>{
|
23
|
+
<value>{fca41611-7e8e-483f-b9fd-e411fe241a81}</value>
|
24
24
|
<display_name>*All Air Loops*</display_name>
|
25
25
|
</choice>
|
26
26
|
</choices>
|
@@ -3,8 +3,8 @@
|
|
3
3
|
<schema_version>3.0</schema_version>
|
4
4
|
<name>set_gas_burner_efficiency</name>
|
5
5
|
<uid>afabec3d-cd02-4908-a367-84e21657421f</uid>
|
6
|
-
<version_id>
|
7
|
-
<version_modified>
|
6
|
+
<version_id>41439c27-7428-4a3c-8745-efc89d618830</version_id>
|
7
|
+
<version_modified>20220506T153447Z</version_modified>
|
8
8
|
<xml_checksum>0DA5C9E6</xml_checksum>
|
9
9
|
<class_name>SetGasBurnerEfficiency</class_name>
|
10
10
|
<display_name>Set Gas Burner Efficiency</display_name>
|
@@ -17,10 +17,10 @@
|
|
17
17
|
<type>Choice</type>
|
18
18
|
<required>true</required>
|
19
19
|
<model_dependent>false</model_dependent>
|
20
|
-
<default_value>{
|
20
|
+
<default_value>{40bd171f-77cb-4e7e-bcb4-2cbce6c09d43}</default_value>
|
21
21
|
<choices>
|
22
22
|
<choice>
|
23
|
-
<value>{
|
23
|
+
<value>{40bd171f-77cb-4e7e-bcb4-2cbce6c09d43}</value>
|
24
24
|
<display_name>*All Air Loops*</display_name>
|
25
25
|
</choice>
|
26
26
|
</choices>
|
@@ -3,8 +3,8 @@
|
|
3
3
|
<schema_version>3.0</schema_version>
|
4
4
|
<name>shift_schedule_profile_time</name>
|
5
5
|
<uid>1c642348-f074-4ad1-98ee-2208ddc89ac7</uid>
|
6
|
-
<version_id>
|
7
|
-
<version_modified>
|
6
|
+
<version_id>c464c0a3-8db6-4c4f-a77d-1da1c003fcec</version_id>
|
7
|
+
<version_modified>20220506T153448Z</version_modified>
|
8
8
|
<xml_checksum>B6CD1F98</xml_checksum>
|
9
9
|
<class_name>ShiftScheduleProfileTime</class_name>
|
10
10
|
<display_name>ShiftScheduleProfileTime</display_name>
|
@@ -17,10 +17,10 @@
|
|
17
17
|
<type>Choice</type>
|
18
18
|
<required>true</required>
|
19
19
|
<model_dependent>false</model_dependent>
|
20
|
-
<default_value>{
|
20
|
+
<default_value>{d79c0411-789b-4733-868c-2765350a45e1}</default_value>
|
21
21
|
<choices>
|
22
22
|
<choice>
|
23
|
-
<value>{
|
23
|
+
<value>{d79c0411-789b-4733-868c-2765350a45e1}</value>
|
24
24
|
<display_name>*All Ruleset Schedules*</display_name>
|
25
25
|
</choice>
|
26
26
|
</choices>
|
@@ -3,15 +3,13 @@
|
|
3
3
|
<schema_version>3.0</schema_version>
|
4
4
|
<name>swap_lights_definition</name>
|
5
5
|
<uid>63845525-5b86-448f-9a34-6be8481496ea</uid>
|
6
|
-
<version_id>
|
7
|
-
<version_modified>
|
6
|
+
<version_id>8ab266db-3cb8-493c-8b16-47474a30bddb</version_id>
|
7
|
+
<version_modified>20220506T153448Z</version_modified>
|
8
8
|
<xml_checksum>293730A7</xml_checksum>
|
9
9
|
<class_name>SwapLightsDefinition</class_name>
|
10
10
|
<display_name>SwapLightsDefinition</display_name>
|
11
11
|
<description>This measure will swap out one lights definition for another. All objects that had referred to the original definition will now refer to the new one.</description>
|
12
|
-
<modeler_description>This measure will not delete or change either definition, rather it just swaps out the references of one for the other. It is possible that the new definition is already used in the model elsewhere.
|
13
|
-
Each of these objects can be independently costed, however the measure can address demolition costs of the object being removed.
|
14
|
-
</modeler_description>
|
12
|
+
<modeler_description>This measure will not delete or change either definition, rather it just swaps out the references of one for the other. It is possible that the new definition is already used in the model elsewhere. Each of these objects can be independently costed, however the measure can address demolition costs of the object being removed.</modeler_description>
|
15
13
|
<arguments>
|
16
14
|
<argument>
|
17
15
|
<name>old_lights_def</name>
|
@@ -0,0 +1,15 @@
|
|
1
|
+
|
2
|
+
|
3
|
+
OpenStudio(R), Copyright (c) 2008-2021, Alliance for Sustainable Energy, LLC. All rights reserved.
|
4
|
+
|
5
|
+
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
|
6
|
+
|
7
|
+
(1) Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
|
8
|
+
|
9
|
+
(2) Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
|
10
|
+
|
11
|
+
(3) Neither the name of the copyright holder nor the names of any contributors may be used to endorse or promote products derived from this software without specific prior written permission from the respective party.
|
12
|
+
|
13
|
+
(4) Other than as required in clauses (1) and (2), distributions in any form of modifications or other derivative works may not use the "OpenStudio" trademark, "OS", "os", or any other confusingly similar designation without specific prior written permission from Alliance for Sustainable Energy, LLC.
|
14
|
+
|
15
|
+
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER, THE UNITED STATES GOVERNMENT, OR ANY CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
@@ -0,0 +1,27 @@
|
|
1
|
+
OpenStudio(R), Copyright (c) 2008-2021, Alliance for Sustainable Energy, LLC. All rights reserved.
|
2
|
+
|
3
|
+
Redistribution and use in source and binary forms, with or without modification, are permitted
|
4
|
+
provided that the following conditions are met:
|
5
|
+
|
6
|
+
(1) Redistributions of source code must retain the above copyright notice, this list of conditions
|
7
|
+
and the following disclaimer.
|
8
|
+
|
9
|
+
(2) Redistributions in binary form must reproduce the above copyright notice, this list of conditions
|
10
|
+
and the following disclaimer in the documentation and/or other materials provided with the distribution.
|
11
|
+
|
12
|
+
(3) Neither the name of the copyright holder nor the names of any contributors may be used to endorse
|
13
|
+
or promote products derived from this software without specific prior written permission from the
|
14
|
+
respective party.
|
15
|
+
|
16
|
+
(4) Other than as required in clauses (1) and (2), distributions in any form of modifications or other
|
17
|
+
derivative works may not use the "OpenStudio" trademark, "OS", "os", or any other confusingly similar
|
18
|
+
designation without specific prior written permission from Alliance for Sustainable Energy, LLC.
|
19
|
+
|
20
|
+
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED
|
21
|
+
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
|
22
|
+
PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER, THE UNITED STATES GOVERNMENT,
|
23
|
+
OR ANY CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
24
|
+
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,
|
25
|
+
OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
|
26
|
+
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
|
27
|
+
SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
@@ -0,0 +1,17 @@
|
|
1
|
+
## Add EMS to Report Emissions
|
2
|
+
## Description
|
3
|
+
This measure reports emissions based on user-provided CSVs.
|
4
|
+
|
5
|
+
## Modeler Description
|
6
|
+
This measure uses EnergyPlus' Energy Management System to log and report emissions based on user provided CSV file(s).
|
7
|
+
|
8
|
+
## Measure Type
|
9
|
+
EnergyPlusMeasure
|
10
|
+
|
11
|
+
## Arguments
|
12
|
+
## Subregion
|
13
|
+
Name: sub_regn, Type: string, Units: none, Required: true, Model Dependent: false. This argument is the eGrid subregion. Options are: AZNM, CAMX, ERCT, FRCC, MROE, MROW, NEWE, NWPP, NYST, RFCE, RFCM, RFCW, RMPA, SPNO, SPSO, SRMV, SRMW, SRSO, SRTV, and SRVC. Default is RMPA.
|
14
|
+
## Future Year
|
15
|
+
Name: fut_year, Type: integer, Units: none, Required: true, Model Dependent: false. This argument is the future year of interest. Options are: 2020 to 2050 in two year increments. Default is 2030.
|
16
|
+
## Historical Year
|
17
|
+
Name: his_year, Type: integer, Units: none, Required: true, Model Dependent: false. This argument is the historical year of interest. Options are: 2007, 2009, 2010, 2012, 2014, 2016, 2018, and 2019. Default is 2010.
|