openstudio-common-measures 0.3.0 → 0.5.0
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/.gitignore +1 -0
- data/.rubocop.yml +3 -1
- data/CHANGELOG.md +43 -0
- data/Jenkinsfile +2 -1
- data/LICENSE.md +1 -1
- data/README.md +14 -0
- data/doc_templates/LICENSE.md +1 -1
- data/doc_templates/copyright_erb.txt +1 -1
- data/doc_templates/copyright_js.txt +1 -1
- data/doc_templates/copyright_ruby.txt +1 -1
- data/lib/measures/AddCostPerAreaToConstruction/LICENSE.md +1 -1
- data/lib/measures/AddCostPerAreaToConstruction/measure.rb +1 -1
- data/lib/measures/AddCostPerAreaToConstruction/measure.xml +8 -7
- data/lib/measures/AddCostPerFloorAreaToBuilding/LICENSE.md +1 -1
- data/lib/measures/AddCostPerFloorAreaToBuilding/measure.rb +1 -1
- data/lib/measures/AddCostPerFloorAreaToBuilding/measure.xml +8 -7
- data/lib/measures/AddCostPerFloorAreaToElectricEquipment/LICENSE.md +1 -1
- data/lib/measures/AddCostPerFloorAreaToElectricEquipment/measure.rb +1 -1
- data/lib/measures/AddCostPerFloorAreaToElectricEquipment/measure.xml +8 -7
- data/lib/measures/AddCostPerFloorAreaToLights/LICENSE.md +1 -1
- data/lib/measures/AddCostPerFloorAreaToLights/measure.rb +1 -1
- data/lib/measures/AddCostPerFloorAreaToLights/measure.xml +8 -7
- data/lib/measures/AddCostPerFloorAreaUnusedToLights/LICENSE.md +1 -1
- data/lib/measures/AddCostPerFloorAreaUnusedToLights/measure.rb +1 -1
- data/lib/measures/AddCostPerFloorAreaUnusedToLights/measure.xml +8 -7
- data/lib/measures/AddCostToSupplySideHVACComponentByAirLoop/LICENSE.md +1 -1
- data/lib/measures/AddCostToSupplySideHVACComponentByAirLoop/measure.rb +1 -1
- data/lib/measures/AddCostToSupplySideHVACComponentByAirLoop/measure.xml +9 -8
- data/lib/measures/AddCostperAreatoUnusedConstruction/LICENSE.md +1 -1
- data/lib/measures/AddCostperAreatoUnusedConstruction/measure.rb +1 -1
- data/lib/measures/AddCostperAreatoUnusedConstruction/measure.xml +8 -7
- data/lib/measures/AddExteriorLights/LICENSE.md +1 -1
- data/lib/measures/AddExteriorLights/measure.rb +1 -1
- data/lib/measures/AddExteriorLights/measure.xml +8 -7
- data/lib/measures/AddMeter/LICENSE.md +1 -1
- data/lib/measures/AddMeter/measure.rb +1 -1
- data/lib/measures/AddMeter/measure.xml +8 -7
- data/lib/measures/AddOutputDiagnostics/LICENSE.md +1 -1
- data/lib/measures/AddOutputDiagnostics/measure.rb +1 -1
- data/lib/measures/AddOutputDiagnostics/measure.xml +8 -7
- data/lib/measures/AddOutputVariable/LICENSE.md +1 -1
- data/lib/measures/AddOutputVariable/measure.rb +1 -1
- data/lib/measures/AddOutputVariable/measure.xml +8 -7
- data/lib/measures/AddSimplePvToShadingSurfacesByType/LICENSE.md +1 -1
- data/lib/measures/AddSimplePvToShadingSurfacesByType/measure.rb +1 -1
- data/lib/measures/AddSimplePvToShadingSurfacesByType/measure.xml +8 -7
- data/lib/measures/AdjustSystemEfficiencies/LICENSE.md +1 -1
- data/lib/measures/AdjustSystemEfficiencies/measure.rb +1 -1
- data/lib/measures/AdjustSystemEfficiencies/measure.xml +7 -6
- data/lib/measures/AdjustThermostatSetpointsByDegrees/LICENSE.md +1 -1
- data/lib/measures/AdjustThermostatSetpointsByDegrees/measure.rb +1 -1
- data/lib/measures/AdjustThermostatSetpointsByDegrees/measure.xml +8 -7
- data/lib/measures/ChangeBuildingLocation/LICENSE.md +1 -1
- data/lib/measures/ChangeBuildingLocation/measure.rb +3 -3
- data/lib/measures/ChangeBuildingLocation/measure.xml +17 -17
- data/lib/measures/ChangeBuildingLocation/resources/epw.rb +1 -1
- data/lib/measures/ChangeBuildingLocation/resources/stat_file.rb +1 -1
- data/lib/measures/EnableIdealAirLoadsForAllZones/LICENSE.md +1 -1
- data/lib/measures/EnableIdealAirLoadsForAllZones/measure.rb +1 -1
- data/lib/measures/EnableIdealAirLoadsForAllZones/measure.xml +9 -8
- data/lib/measures/ExportScheduleCSV/LICENSE.md +1 -1
- data/lib/measures/ExportScheduleCSV/measure.rb +1 -1
- data/lib/measures/ExportScheduleCSV/measure.xml +11 -11
- data/lib/measures/ImportEnvelopeAndInternalLoadsFromIdf/LICENSE.md +1 -1
- data/lib/measures/ImportEnvelopeAndInternalLoadsFromIdf/measure.rb +1 -1
- data/lib/measures/ImportEnvelopeAndInternalLoadsFromIdf/measure.xml +5 -5
- data/lib/measures/MeterFlodPlot/LICENSE.md +1 -1
- data/lib/measures/MeterFlodPlot/measure.rb +1 -1
- data/lib/measures/MeterFlodPlot/measure.xml +11 -11
- data/lib/measures/ModifyEnergyPlusCoilCoolingDXSingleSpeedObjects/LICENSE.md +1 -1
- data/lib/measures/ModifyEnergyPlusCoilCoolingDXSingleSpeedObjects/measure.rb +1 -1
- data/lib/measures/ModifyEnergyPlusCoilCoolingDXSingleSpeedObjects/measure.xml +8 -7
- data/lib/measures/ModifyEnergyPlusFanVariableVolumeObjects/LICENSE.md +1 -1
- data/lib/measures/ModifyEnergyPlusFanVariableVolumeObjects/measure.rb +1 -1
- data/lib/measures/ModifyEnergyPlusFanVariableVolumeObjects/measure.xml +8 -7
- data/lib/measures/PredictedMeanVote/LICENSE.md +1 -1
- data/lib/measures/PredictedMeanVote/measure.rb +1 -1
- data/lib/measures/PredictedMeanVote/measure.xml +14 -13
- data/lib/measures/RemoveInternalLoadsDirectlyAssignedToSpaces/LICENSE.md +1 -1
- data/lib/measures/RemoveInternalLoadsDirectlyAssignedToSpaces/measure.rb +1 -1
- data/lib/measures/RemoveInternalLoadsDirectlyAssignedToSpaces/measure.xml +9 -8
- data/lib/measures/RemoveUnusedDefaultProfiles/LICENSE.md +1 -1
- data/lib/measures/RemoveUnusedDefaultProfiles/measure.rb +1 -1
- data/lib/measures/RemoveUnusedDefaultProfiles/measure.xml +9 -8
- data/lib/measures/ReplaceExteriorWindowConstruction/LICENSE.md +1 -1
- data/lib/measures/ReplaceExteriorWindowConstruction/measure.rb +1 -1
- data/lib/measures/ReplaceExteriorWindowConstruction/measure.xml +11 -10
- data/lib/measures/ReplaceThermostatSchedules/LICENSE.md +1 -1
- data/lib/measures/ReplaceThermostatSchedules/measure.rb +1 -1
- data/lib/measures/ReplaceThermostatSchedules/measure.xml +12 -11
- data/lib/measures/ReportModelChanges/LICENSE.md +1 -1
- data/lib/measures/ReportModelChanges/measure.rb +1 -1
- data/lib/measures/ReportModelChanges/measure.xml +5 -5
- data/lib/measures/RunPeriod/LICENSE.md +1 -1
- data/lib/measures/RunPeriod/measure.rb +1 -1
- data/lib/measures/RunPeriod/measure.xml +19 -18
- data/lib/measures/RunPeriodMultiple/LICENSE.md +1 -1
- data/lib/measures/RunPeriodMultiple/measure.rb +1 -1
- data/lib/measures/RunPeriodMultiple/measure.xml +4 -4
- data/lib/measures/ServerDirectoryCleanup/LICENSE.md +1 -1
- data/lib/measures/ServerDirectoryCleanup/measure.rb +1 -1
- data/lib/measures/ServerDirectoryCleanup/measure.xml +16 -16
- data/lib/measures/SetCOPforSingleSpeedDXCoolingUnits/LICENSE.md +1 -1
- data/lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.rb +1 -1
- data/lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.xml +10 -9
- data/lib/measures/SetCOPforTwoSpeedDXCoolingUnits/LICENSE.md +1 -1
- data/lib/measures/SetCOPforTwoSpeedDXCoolingUnits/measure.rb +1 -1
- data/lib/measures/SetCOPforTwoSpeedDXCoolingUnits/measure.xml +10 -9
- data/lib/measures/SetEnergyPlusInfiltrationFlowRatePerFloorArea/LICENSE.md +1 -1
- data/lib/measures/SetEnergyPlusInfiltrationFlowRatePerFloorArea/measure.rb +1 -1
- data/lib/measures/SetEnergyPlusInfiltrationFlowRatePerFloorArea/measure.xml +8 -7
- data/lib/measures/SetEnergyPlusLightObjectsLPD/LICENSE.md +1 -1
- data/lib/measures/SetEnergyPlusLightObjectsLPD/measure.rb +1 -1
- data/lib/measures/SetEnergyPlusLightObjectsLPD/measure.xml +8 -7
- data/lib/measures/SetEnergyPlusMinimumOutdoorAirFlowRate/LICENSE.md +1 -1
- data/lib/measures/SetEnergyPlusMinimumOutdoorAirFlowRate/measure.rb +1 -1
- data/lib/measures/SetEnergyPlusMinimumOutdoorAirFlowRate/measure.xml +8 -7
- data/lib/measures/SetGasBurnerEfficiency/LICENSE.md +1 -1
- data/lib/measures/SetGasBurnerEfficiency/measure.rb +1 -1
- data/lib/measures/SetGasBurnerEfficiency/measure.xml +10 -9
- data/lib/measures/SetLifecycleCostParameters/LICENSE.md +1 -1
- data/lib/measures/SetLifecycleCostParameters/measure.rb +1 -1
- data/lib/measures/SetLifecycleCostParameters/measure.xml +8 -7
- data/lib/measures/SetLightingLoadsByLPD/LICENSE.md +1 -1
- data/lib/measures/SetLightingLoadsByLPD/measure.rb +1 -1
- data/lib/measures/SetLightingLoadsByLPD/measure.xml +10 -9
- data/lib/measures/SetSpaceInfiltrationByExteriorSurfaceArea/LICENSE.md +1 -1
- data/lib/measures/SetSpaceInfiltrationByExteriorSurfaceArea/measure.rb +1 -1
- data/lib/measures/SetSpaceInfiltrationByExteriorSurfaceArea/measure.xml +20 -19
- data/lib/measures/SetThermostatSchedules/LICENSE.md +1 -1
- data/lib/measures/SetThermostatSchedules/measure.rb +1 -1
- data/lib/measures/SetThermostatSchedules/measure.xml +12 -11
- data/lib/measures/ShiftScheduleProfileTime/LICENSE.md +1 -1
- data/lib/measures/ShiftScheduleProfileTime/measure.rb +1 -1
- data/lib/measures/ShiftScheduleProfileTime/measure.xml +10 -9
- data/lib/measures/SwapLightsDefinition/LICENSE.md +1 -1
- data/lib/measures/SwapLightsDefinition/measure.rb +1 -1
- data/lib/measures/SwapLightsDefinition/measure.xml +10 -9
- data/lib/measures/UnmetLoadHoursTroubleshooting/LICENSE.md +1 -1
- data/lib/measures/UnmetLoadHoursTroubleshooting/measure.rb +1 -1
- data/lib/measures/UnmetLoadHoursTroubleshooting/measure.xml +11 -11
- data/lib/measures/VentilationQAQC/LICENSE.md +1 -1
- data/lib/measures/VentilationQAQC/measure.rb +1 -1
- data/lib/measures/VentilationQAQC/measure.xml +17 -17
- data/lib/measures/ZoneReport/LICENSE.md +1 -1
- data/lib/measures/ZoneReport/measure.rb +1 -1
- data/lib/measures/ZoneReport/measure.xml +11 -11
- data/lib/measures/add_ems_emissions_reporting/LICENSE.MD.txt +15 -0
- data/lib/measures/{AddDaylightSensors → add_ems_emissions_reporting}/LICENSE.md +1 -1
- data/lib/measures/add_ems_emissions_reporting/README.md +17 -0
- data/lib/measures/add_ems_emissions_reporting/measure.rb +268 -0
- data/lib/measures/add_ems_emissions_reporting/measure.xml +247 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_annual_co2e.csv +17 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2020.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2022.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2024.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2026.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2028.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2030.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2032.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2034.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2036.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2038.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2040.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2042.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2044.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2046.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2048.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/future_hourly_co2e_2050.csv +8761 -0
- data/lib/measures/add_ems_emissions_reporting/resources/historical_annual_co2e.csv +9 -0
- data/lib/measures/add_ems_emissions_reporting/resources/historical_hourly_co2e_2019.csv +8761 -0
- data/lib/measures/add_ems_to_control_ev_charging/LICENSE.MD.txt +1 -1
- data/lib/measures/add_ems_to_control_ev_charging/LICENSE.md +1 -1
- data/lib/measures/add_ems_to_control_ev_charging/measure.rb +2 -1
- data/lib/measures/add_ems_to_control_ev_charging/measure.xml +14 -10
- data/lib/measures/add_ev_load/LICENSE.MD.txt +1 -1
- data/lib/measures/add_ev_load/LICENSE.md +1 -1
- data/lib/measures/add_ev_load/measure.rb +5 -2
- data/lib/measures/add_ev_load/measure.xml +210 -15
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/PSN_BuildingKey.csv → PSN_BuildingKey.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/PSN_BuildingKey_v2.csv → PSN_BuildingKey_v2.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg1_dow1_flex1.csv → chg1_dow1_flex1.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg1_dow1_flex2.csv → chg1_dow1_flex2.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg1_dow1_flex3.csv → chg1_dow1_flex3.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg1_dow2_flex1.csv → chg1_dow2_flex1.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg1_dow2_flex2.csv → chg1_dow2_flex2.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg1_dow2_flex3.csv → chg1_dow2_flex3.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg1_dow3_flex1.csv → chg1_dow3_flex1.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg1_dow3_flex2.csv → chg1_dow3_flex2.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg1_dow3_flex3.csv → chg1_dow3_flex3.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg2_dow1_flex1.csv → chg2_dow1_flex1.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg2_dow1_flex2.csv → chg2_dow1_flex2.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg2_dow1_flex3.csv → chg2_dow1_flex3.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg2_dow2_flex1.csv → chg2_dow2_flex1.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg2_dow2_flex2.csv → chg2_dow2_flex2.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg2_dow2_flex3.csv → chg2_dow2_flex3.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg2_dow3_flex1.csv → chg2_dow3_flex1.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg2_dow3_flex2.csv → chg2_dow3_flex2.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg2_dow3_flex3.csv → chg2_dow3_flex3.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg3_dow1_flex1.csv → chg3_dow1_flex1.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg3_dow1_flex2.csv → chg3_dow1_flex2.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg3_dow1_flex3.csv → chg3_dow1_flex3.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg3_dow2_flex1.csv → chg3_dow2_flex1.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg3_dow2_flex2.csv → chg3_dow2_flex2.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg3_dow2_flex3.csv → chg3_dow2_flex3.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg3_dow3_flex1.csv → chg3_dow3_flex1.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg3_dow3_flex2.csv → chg3_dow3_flex2.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/chg3_dow3_flex3.csv → chg3_dow3_flex3.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/fast_charge_15min_Saturday.csv → fast_charge_15min_Saturday.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/fast_charge_15min_Sunday.csv → fast_charge_15min_Sunday.csv} +0 -0
- data/lib/measures/add_ev_load/resources/{EV_Load_Profiles/fast_charge_15min_Weekday.csv → fast_charge_15min_Weekday.csv} +0 -0
- data/lib/measures/add_rooftop_pv/LICENSE.md +1 -1
- data/lib/measures/add_rooftop_pv/measure.rb +1 -1
- data/lib/measures/add_rooftop_pv/measure.xml +5 -5
- data/lib/measures/add_zone_mixing_object/LICENSE.md +1 -1
- data/lib/measures/add_zone_mixing_object/measure.rb +1 -1
- data/lib/measures/add_zone_mixing_object/measure.xml +8 -7
- data/lib/measures/add_zone_ventilation_design_flow_rate_object/LICENSE.md +1 -1
- data/lib/measures/add_zone_ventilation_design_flow_rate_object/measure.rb +1 -1
- data/lib/measures/add_zone_ventilation_design_flow_rate_object/measure.xml +8 -7
- data/lib/measures/air_wall_zone_mixing/LICENSE.md +1 -1
- data/lib/measures/air_wall_zone_mixing/measure.rb +1 -1
- data/lib/measures/air_wall_zone_mixing/measure.xml +5 -5
- data/lib/measures/envelope_and_internal_load_breakdown/LICENSE.md +1 -1
- data/lib/measures/envelope_and_internal_load_breakdown/measure.rb +1 -1
- data/lib/measures/envelope_and_internal_load_breakdown/measure.xml +8 -8
- data/lib/measures/envelope_and_internal_load_breakdown/resources/os_lib_reporting_envelope_and_internal_loads_breakdown.rb +1 -1
- data/lib/measures/envelope_and_internal_load_breakdown/resources/report.html.erb +4 -1
- data/lib/measures/example_report/LICENSE.md +1 -1
- data/lib/measures/example_report/measure.rb +1 -1
- data/lib/measures/example_report/measure.xml +14 -14
- data/lib/measures/example_report/resources/os_lib_reporting_example.rb +1 -1
- data/lib/measures/example_report/resources/report.html.erb +4 -1
- data/lib/measures/gem_env_report/LICENSE.md +1 -1
- data/lib/measures/gem_env_report/measure.rb +1 -1
- data/lib/measures/gem_env_report/measure.xml +13 -12
- data/lib/measures/gem_env_report/resources/gem_env_info.rb +1 -1
- data/lib/measures/gem_env_report/resources/openstudio_info.rb +1 -1
- data/lib/measures/gem_env_report/resources/run_gem_env_info.rb +1 -1
- data/lib/measures/gem_env_report/resources/run_openstudio_info.rb +1 -1
- data/lib/measures/generic_qaqc/LICENSE.md +1 -1
- data/lib/measures/generic_qaqc/measure.rb +6 -1
- data/lib/measures/generic_qaqc/measure.xml +48 -54
- data/lib/measures/generic_qaqc/resources/CreateResults.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_air_sys_temps.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_calibration.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_cond_zns.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_domestic_hot_water.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_envelope_conductance.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_eui_by_end_use.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_eui_reasonableness.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_fan_pwr.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_internal_loads.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_mech_sys_capacity.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_mech_sys_efficiency.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_mech_sys_part_load_eff.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_mech_sys_type.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_part_loads.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_placeholder.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_plant_cap.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_plant_temps.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_plenum_loads.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_pump_pwr.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_sch_coord.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_schedules.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_simultaneous_heating_and_cooling.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_supply_air_and_thermostat_temp_difference.rb +1 -1
- data/lib/measures/generic_qaqc/resources/check_weather_files.rb +1 -1
- data/lib/measures/generic_qaqc/resources/os_lib_reporting_qaqc.rb +1 -1
- data/lib/measures/generic_qaqc/resources/report.html.erb +4 -1
- data/lib/measures/get_site_from_building_component_library/LICENSE.md +1 -1
- data/lib/measures/get_site_from_building_component_library/measure.rb +1 -1
- data/lib/measures/get_site_from_building_component_library/measure.xml +6 -6
- data/lib/measures/hvac_psychrometric_chart/LICENSE.md +1 -1
- data/lib/measures/hvac_psychrometric_chart/measure.rb +1 -1
- data/lib/measures/hvac_psychrometric_chart/measure.xml +15 -15
- data/lib/measures/hvac_psychrometric_chart/resources/report.html.erb +4 -1
- data/lib/measures/inject_idf_objects/LICENSE.md +1 -1
- data/lib/measures/inject_idf_objects/measure.rb +1 -1
- data/lib/measures/inject_idf_objects/measure.xml +10 -10
- data/lib/measures/openstudio_results/LICENSE.md +1 -1
- data/lib/measures/openstudio_results/measure.rb +6 -4
- data/lib/measures/openstudio_results/measure.xml +174 -162
- data/lib/measures/openstudio_results/resources/Siz.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirLoopHVAC.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirLoopHVACUnitaryHeatPumpAirToAir.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirLoopHVACUnitarySystem.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirTerminalDualDuctVAV.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctConstantVolumeCooledBeam.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctConstantVolumeFourPipeInduction.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctConstantVolumeReheat.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctSeriesPIUReheat.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctUncontrolled.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctVAVHeatAndCoolNoReheat.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctVAVHeatAndCoolReheat.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctVAVNoReheat.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.BoilerHotWater.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.BoilerSteam.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ChillerAbsorption.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ChillerAbsorptionIndirect.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ChillerElectricEIR.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ChillerHeaterPerformanceElectricEIR.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXMultiSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXMultiSpeedStageData.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXSingleSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXTwoStageWithHumidityControlMode.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXVariableRefrigerantFlow.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXVariableSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXVariableSpeedSpeedData.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingLowTempRadiantVarFlow.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingWater.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingWaterToAirHeatPumpVariableSpeedEquationFit.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilCoolingWaterToAirHeatPumpVariableSpeedEquationFitSpeedData.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXMultiSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXMultiSpeedStageData.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXVariableRefrigerantFlow.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXVariableSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXVariableSpeedSpeedData.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDesuperheater.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingElectric.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingGas.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingGasMultiStage.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingGasMultiStageStageData.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingLowTempRadiantVarFlow.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWater.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWaterBaseboard.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWaterBaseboardRadiant.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWaterToAirHeatPumpVariableSpeedEquationFit.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWaterToAirHeatPumpVariableSpeedEquationFitSpeedData.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilPerformanceDXCooling.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilSystemCoolingDXHeatExchangerAssisted.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilSystemCoolingWaterHeatExchangerAssisted.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilWaterHeatingAirToWaterHeatPump.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilWaterHeatingAirToWaterHeatPumpWrapped.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoilWaterHeatingDesuperheater.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ControllerOutdoorAir.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoolingTowerSingleSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoolingTowerTwoSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.DistrictCooling.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.DistrictHeating.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ElectricLoadCenterInverterLookUpTable.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ElectricLoadCenterInverterSimple.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ElectricLoadCenterStorageConverter.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ElectricLoadCenterStorageSimple.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.EvaporativeCoolerDirectResearchSpecial.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.EvaporativeCoolerIndirectResearchSpecial.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.EvaporativeFluidCoolerSingleSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.EvaporativeFluidCoolerTwoSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.FanConstantVolume.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.FanOnOff.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.FanVariableVolume.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.FanZoneExhaust.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.FluidCoolerSingleSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.FluidCoolerTwoSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.GeneratorFuelCellElectricalStorage.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.GeneratorFuelCellInverter.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.GeneratorFuelCellPowerModule.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.GeneratorMicroTurbine.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.GeneratorMicroTurbineHeatRecovery.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.HVACComponent.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.HeaderedPumpsConstantSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.HeaderedPumpsVariableSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.HeatExchangerFluidToFluid.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.HeatPumpWaterToWaterEquationFitCooling.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.HeatPumpWaterToWaterEquationFitHeating.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.HumidifierSteamElectric.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.Model.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ModelObject.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.PhotovoltaicPerformanceSimple.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.PlantComponentTemperatureSource.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.PlantLoop.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.PumpConstantSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.PumpVariableSpeed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.RefrigerationSecondarySystem.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.RefrigerationSystem.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.RefrigerationTranscriticalSystem.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.SizingSystem.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.SolarCollectorFlatPlatePhotovoltaicThermal.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.SolarCollectorPerformancePhotovoltaicThermalSimple.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ThermalStorageChilledWaterStratified.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.WaterHeaterHeatPump.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.WaterHeaterHeatPumpWrappedCondenser.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.WaterHeaterMixed.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.WaterHeaterStratified.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACBaseboardConvectiveElectric.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACBaseboardConvectiveWater.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACBaseboardRadiantConvectiveElectric.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACBaseboardRadiantConvectiveWater.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACEnergyRecoveryVentilator.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACFourPipeFanCoil.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACHighTemperatureRadiant.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACIdealLoadsAirSystem.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACLowTempRadiantConstFlow.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACLowTempRadiantVarFlow.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACPackagedTerminalAirConditioner.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACPackagedTerminalHeatPump.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACUnitHeater.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACUnitVentilator.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneHVACWaterToAirHeatPump.rb +1 -1
- data/lib/measures/openstudio_results/resources/Siz.ZoneVentilationDesignFlowRate.rb +1 -1
- data/lib/measures/openstudio_results/resources/os_lib_reporting.rb +2 -2
- data/lib/measures/openstudio_results/resources/report.html.erb +4 -1
- data/lib/measures/remove_orphan_objects_and_unused_resources/LICENSE.md +1 -1
- data/lib/measures/remove_orphan_objects_and_unused_resources/measure.rb +1 -1
- data/lib/measures/remove_orphan_objects_and_unused_resources/measure.xml +8 -7
- data/lib/measures/set_electric_equipment_loads_by_epd/LICENSE.md +1 -1
- data/lib/measures/set_electric_equipment_loads_by_epd/measure.rb +1 -1
- data/lib/measures/set_electric_equipment_loads_by_epd/measure.xml +10 -9
- data/lib/measures/set_exterior_walls_and_floors_to_adiabatic/LICENSE.md +1 -1
- data/lib/measures/set_exterior_walls_and_floors_to_adiabatic/measure.rb +1 -1
- data/lib/measures/set_exterior_walls_and_floors_to_adiabatic/measure.xml +17 -11
- data/lib/measures/set_run_period/LICENSE.md +1 -1
- data/lib/measures/set_run_period/measure.rb +1 -1
- data/lib/measures/set_run_period/measure.xml +5 -5
- data/lib/measures/set_space_infiltration_per_exterior_area/LICENSE.md +1 -1
- data/lib/measures/set_space_infiltration_per_exterior_area/measure.rb +1 -1
- data/lib/measures/set_space_infiltration_per_exterior_area/measure.xml +8 -7
- data/lib/measures/tariff_selection_block/LICENSE.md +1 -1
- data/lib/measures/tariff_selection_block/measure.rb +2 -2
- data/lib/measures/tariff_selection_block/measure.xml +5 -5
- data/lib/measures/tariff_selection_flat/LICENSE.md +1 -1
- data/lib/measures/tariff_selection_flat/measure.rb +2 -2
- data/lib/measures/tariff_selection_flat/measure.xml +5 -5
- data/lib/measures/tariff_selection_generic/LICENSE.md +1 -1
- data/lib/measures/tariff_selection_generic/README.md +2 -2
- data/lib/measures/tariff_selection_generic/measure.rb +1 -1
- data/lib/measures/tariff_selection_generic/measure.xml +25 -25
- data/lib/measures/tariff_selection_generic/resources/FlatEnergyCharge-Gas.idf +3 -3
- data/lib/measures/tariff_selection_generic/resources/IN-EIAMonthlyRateGas.idf +1 -1
- data/lib/measures/tariff_selection_time_and_date_dependant/LICENSE.md +1 -1
- data/lib/measures/tariff_selection_time_and_date_dependant/measure.rb +2 -2
- data/lib/measures/tariff_selection_time_and_date_dependant/measure.xml +5 -5
- data/lib/measures/view_data/LICENSE.md +1 -1
- data/lib/measures/view_data/measure.rb +1 -1
- data/lib/measures/view_data/measure.xml +32 -32
- data/lib/measures/view_data/resources/report.html.in +1149 -956
- data/lib/measures/view_data/resources/va3c.rb +1 -1
- data/lib/measures/view_model/LICENSE.md +1 -1
- data/lib/measures/view_model/measure.rb +1 -1
- data/lib/measures/view_model/measure.xml +27 -27
- data/lib/measures/view_model/resources/report.html.in +1152 -959
- data/lib/measures/view_model/resources/va3c.rb +1 -1
- data/lib/openstudio/common_measures/extension.rb +1 -1
- data/lib/openstudio/common_measures/version.rb +2 -2
- data/lib/openstudio/common_measures.rb +1 -1
- data/lib/openstudio-common-measures.rb +1 -1
- data/openstudio-common-measures.gemspec +4 -4
- metadata +67 -107
- data/lib/measures/AddDaylightSensors/README.md +0 -136
- data/lib/measures/AddDaylightSensors/README.md.erb +0 -42
- data/lib/measures/AddDaylightSensors/measure.rb +0 -521
- data/lib/measures/AddDaylightSensors/measure.xml +0 -233
- data/lib/measures/EnableDemandControlledVentilation/LICENSE.md +0 -27
- data/lib/measures/EnableDemandControlledVentilation/README.md +0 -32
- data/lib/measures/EnableDemandControlledVentilation/README.md.erb +0 -42
- data/lib/measures/EnableDemandControlledVentilation/measure.rb +0 -154
- data/lib/measures/EnableDemandControlledVentilation/measure.xml +0 -99
- data/lib/measures/EnableEconomizerControl/LICENSE.md +0 -27
- data/lib/measures/EnableEconomizerControl/README.md +0 -48
- data/lib/measures/EnableEconomizerControl/README.md.erb +0 -42
- data/lib/measures/EnableEconomizerControl/measure.rb +0 -172
- data/lib/measures/EnableEconomizerControl/measure.xml +0 -124
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md +0 -64
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.rb +0 -422
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.xml +0 -150
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/README.md +0 -32
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/measure.rb +0 -328
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/measure.xml +0 -98
- data/lib/measures/IncreaseInsulationRValueForRoofs/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForRoofs/README.md +0 -64
- data/lib/measures/IncreaseInsulationRValueForRoofs/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForRoofs/measure.rb +0 -422
- data/lib/measures/IncreaseInsulationRValueForRoofs/measure.xml +0 -143
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/README.md +0 -32
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/measure.rb +0 -328
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/measure.xml +0 -98
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md +0 -97
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.rb +0 -450
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.xml +0 -186
- data/lib/measures/ReduceLightingLoadsByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceLightingLoadsByPercentage/README.md +0 -96
- data/lib/measures/ReduceLightingLoadsByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceLightingLoadsByPercentage/measure.rb +0 -513
- data/lib/measures/ReduceLightingLoadsByPercentage/measure.xml +0 -191
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md +0 -104
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.rb +0 -349
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.xml +0 -181
- data/lib/measures/ReduceVentilationByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceVentilationByPercentage/README.md +0 -40
- data/lib/measures/ReduceVentilationByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceVentilationByPercentage/measure.rb +0 -291
- data/lib/measures/ReduceVentilationByPercentage/measure.xml +0 -96
- data/lib/measures/create_variable_speed_rtu/LICENSE.md +0 -27
- data/lib/measures/create_variable_speed_rtu/README.md +0 -120
- data/lib/measures/create_variable_speed_rtu/README.md.erb +0 -42
- data/lib/measures/create_variable_speed_rtu/measure.rb +0 -539
- data/lib/measures/create_variable_speed_rtu/measure.xml +0 -207
- data/lib/measures/generic_qaqc/resources/os_lib_helper_methods.rb +0 -399
- data/lib/measures/openstudio_results/resources/os_lib_helper_methods.rb +0 -399
- data/lib/measures/openstudio_results/resources/os_lib_schedules.rb +0 -962
@@ -1,42 +0,0 @@
|
|
1
|
-
<%#= README.md.erb is used to auto-generate README.md. %>
|
2
|
-
<%#= To manually maintain README.md throw away README.md.erb and manually edit README.md %>
|
3
|
-
###### (Automatically generated documentation)
|
4
|
-
|
5
|
-
# <%= name %>
|
6
|
-
|
7
|
-
## Description
|
8
|
-
<%= description %>
|
9
|
-
|
10
|
-
## Modeler Description
|
11
|
-
<%= modelerDescription %>
|
12
|
-
|
13
|
-
## Measure Type
|
14
|
-
<%= measureType %>
|
15
|
-
|
16
|
-
## Taxonomy
|
17
|
-
<%= taxonomy %>
|
18
|
-
|
19
|
-
## Arguments
|
20
|
-
|
21
|
-
<% arguments.each do |argument| %>
|
22
|
-
### <%= argument[:display_name] %>
|
23
|
-
<%= argument[:description] %>
|
24
|
-
**Name:** <%= argument[:name] %>,
|
25
|
-
**Type:** <%= argument[:type] %>,
|
26
|
-
**Units:** <%= argument[:units] %>,
|
27
|
-
**Required:** <%= argument[:required] %>,
|
28
|
-
**Model Dependent:** <%= argument[:model_dependent] %>
|
29
|
-
<% end %>
|
30
|
-
|
31
|
-
<% if arguments.size == 0 %>
|
32
|
-
<%= "This measure does not have any user arguments" %>
|
33
|
-
<% end %>
|
34
|
-
|
35
|
-
<% if outputs.size > 0 %>
|
36
|
-
## Outputs
|
37
|
-
<% output_names = [] %>
|
38
|
-
<% outputs.each do |output| %>
|
39
|
-
<% output_names << output[:display_name] %>
|
40
|
-
<% end %>
|
41
|
-
<%= output_names.join(", ") %>
|
42
|
-
<% end %>
|
@@ -1,328 +0,0 @@
|
|
1
|
-
# *******************************************************************************
|
2
|
-
# OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC.
|
3
|
-
# All rights reserved.
|
4
|
-
# Redistribution and use in source and binary forms, with or without
|
5
|
-
# modification, are permitted provided that the following conditions are met:
|
6
|
-
#
|
7
|
-
# (1) Redistributions of source code must retain the above copyright notice,
|
8
|
-
# this list of conditions and the following disclaimer.
|
9
|
-
#
|
10
|
-
# (2) Redistributions in binary form must reproduce the above copyright notice,
|
11
|
-
# this list of conditions and the following disclaimer in the documentation
|
12
|
-
# and/or other materials provided with the distribution.
|
13
|
-
#
|
14
|
-
# (3) Neither the name of the copyright holder nor the names of any contributors
|
15
|
-
# may be used to endorse or promote products derived from this software without
|
16
|
-
# specific prior written permission from the respective party.
|
17
|
-
#
|
18
|
-
# (4) Other than as required in clauses (1) and (2), distributions in any form
|
19
|
-
# of modifications or other derivative works may not use the "OpenStudio"
|
20
|
-
# trademark, "OS", "os", or any other confusingly similar designation without
|
21
|
-
# specific prior written permission from Alliance for Sustainable Energy, LLC.
|
22
|
-
#
|
23
|
-
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS
|
24
|
-
# "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
|
25
|
-
# THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
26
|
-
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE
|
27
|
-
# UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF
|
28
|
-
# THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
|
29
|
-
# EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT
|
30
|
-
# OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
|
31
|
-
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
|
32
|
-
# STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
33
|
-
# OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
34
|
-
# *******************************************************************************
|
35
|
-
|
36
|
-
# start the measure
|
37
|
-
class IncreaseInsulationRValueForExteriorWallsByPercentage < OpenStudio::Ruleset::ModelUserScript
|
38
|
-
# define the name that a user will see
|
39
|
-
def name
|
40
|
-
return 'Increase R-value of Insulation for Exterior Walls By a Specified Percentage'
|
41
|
-
end
|
42
|
-
|
43
|
-
# define the arguments that the user will input
|
44
|
-
def arguments(model)
|
45
|
-
args = OpenStudio::Ruleset::OSArgumentVector.new
|
46
|
-
|
47
|
-
# make an argument insulation R-value
|
48
|
-
r_value = OpenStudio::Ruleset::OSArgument.makeDoubleArgument('r_value', true)
|
49
|
-
r_value.setDisplayName('Percentage Increase of R-value for Exterior Wall Insulation.')
|
50
|
-
r_value.setDefaultValue(30.0)
|
51
|
-
args << r_value
|
52
|
-
|
53
|
-
return args
|
54
|
-
end
|
55
|
-
|
56
|
-
# define what happens when the measure is run
|
57
|
-
def run(model, runner, user_arguments)
|
58
|
-
super(model, runner, user_arguments)
|
59
|
-
|
60
|
-
# use the built-in error checking
|
61
|
-
if !runner.validateUserArguments(arguments(model), user_arguments)
|
62
|
-
return false
|
63
|
-
end
|
64
|
-
|
65
|
-
# assign the user inputs to variables
|
66
|
-
r_value = runner.getDoubleArgumentValue('r_value', user_arguments)
|
67
|
-
|
68
|
-
# set limit for minimum insulation. This is used to limit input and for inferring insulation layer in construction.
|
69
|
-
min_expected_r_value_ip = 1 # ip units
|
70
|
-
|
71
|
-
# check the R-value for reasonableness
|
72
|
-
if r_value < -100
|
73
|
-
runner.registerError('Percentage increase less than -100% is not valid.')
|
74
|
-
return false
|
75
|
-
end
|
76
|
-
|
77
|
-
# short def to make numbers pretty (converts 4125001.25641 to 4,125,001.26 or 4,125,001). The definition be called through this measure
|
78
|
-
def neat_numbers(number, roundto = 2) # round to 0 or 2)
|
79
|
-
if roundto == 2
|
80
|
-
number = format '%.2f', number
|
81
|
-
else
|
82
|
-
number = number.round
|
83
|
-
end
|
84
|
-
# regex to add commas
|
85
|
-
number.to_s.reverse.gsub(/([0-9]{3}(?=([0-9])))/, '\\1,').reverse
|
86
|
-
end
|
87
|
-
|
88
|
-
# helper to make it easier to do unit conversions on the fly
|
89
|
-
def unit_helper(number, from_unit_string, to_unit_string)
|
90
|
-
converted_number = OpenStudio.convert(OpenStudio::Quantity.new(number, OpenStudio.createUnit(from_unit_string).get), OpenStudio.createUnit(to_unit_string).get).get.value
|
91
|
-
end
|
92
|
-
|
93
|
-
# create an array of exterior surfaces and find range of starting construction R-value (not just insulation layer)
|
94
|
-
surfaces = model.getSurfaces
|
95
|
-
exterior_surfaces = []
|
96
|
-
exterior_surface_constructions = []
|
97
|
-
exterior_surface_construction_names = []
|
98
|
-
exterior_surface_resistance = []
|
99
|
-
surfaces.each do |surface|
|
100
|
-
if (surface.outsideBoundaryCondition == 'Outdoors') && (surface.surfaceType == 'Wall')
|
101
|
-
exterior_surfaces << surface
|
102
|
-
exterior_surface_const = surface.construction.get
|
103
|
-
# only add construction if it hasn't been added yet
|
104
|
-
if !exterior_surface_construction_names.include?(exterior_surface_const.name.to_s)
|
105
|
-
exterior_surface_constructions << exterior_surface_const.to_Construction.get
|
106
|
-
end
|
107
|
-
exterior_surface_construction_names << exterior_surface_const.name.to_s
|
108
|
-
exterior_surface_resistance << 1 / exterior_surface_const.thermalConductance.to_f
|
109
|
-
end
|
110
|
-
end
|
111
|
-
|
112
|
-
# nothing will be done if there are no exterior surfaces
|
113
|
-
if exterior_surfaces.empty?
|
114
|
-
runner.registerAsNotApplicable('Model does not have any exterior walls.')
|
115
|
-
return true
|
116
|
-
end
|
117
|
-
|
118
|
-
# report strings for initial condition
|
119
|
-
initial_string = []
|
120
|
-
exterior_surface_constructions.uniq.each do |exterior_surface_construction|
|
121
|
-
# unit conversion of exterior surface insulation from SI units (M^2*K/W) to IP units (ft^2*h*R/Btu)
|
122
|
-
initial_conductance_ip = unit_helper(1 / exterior_surface_construction.thermalConductance.to_f, 'm^2*K/W', 'ft^2*h*R/Btu')
|
123
|
-
initial_string << "#{exterior_surface_construction.name} (R-#{(format '%.1f', initial_conductance_ip)})"
|
124
|
-
end
|
125
|
-
runner.registerInitialCondition("The building had #{initial_string.size} exterior wall constructions: #{initial_string.sort.join(', ')}.")
|
126
|
-
|
127
|
-
# hashes to track constructions and materials made by the measure, to avoid duplicates
|
128
|
-
constructions_hash_old_new = {}
|
129
|
-
constructions_hash_new_old = {} # used to get netArea of new construction and then cost objects of construction it replaced
|
130
|
-
materials_hash = {}
|
131
|
-
|
132
|
-
# array and counter for new constructions that are made, used for reporting final condition
|
133
|
-
final_constructions_array = []
|
134
|
-
|
135
|
-
# loop through all constructions and materials used on exterior walls, edit and clone
|
136
|
-
exterior_surface_constructions.each do |exterior_surface_construction|
|
137
|
-
construction_layers = exterior_surface_construction.layers
|
138
|
-
max_thermal_resistance_material = ''
|
139
|
-
max_thermal_resistance_material_index = ''
|
140
|
-
counter = 0
|
141
|
-
thermal_resistance_values = []
|
142
|
-
|
143
|
-
# loop through construction layers and infer insulation layer/material
|
144
|
-
construction_layers.each do |construction_layer|
|
145
|
-
construction_layer_r_value = construction_layer.to_OpaqueMaterial.get.thermalResistance
|
146
|
-
if !thermal_resistance_values.empty?
|
147
|
-
if construction_layer_r_value > thermal_resistance_values.max
|
148
|
-
max_thermal_resistance_material = construction_layer
|
149
|
-
max_thermal_resistance_material_index = counter
|
150
|
-
end
|
151
|
-
end
|
152
|
-
thermal_resistance_values << construction_layer_r_value
|
153
|
-
counter += 1
|
154
|
-
end
|
155
|
-
|
156
|
-
if thermal_resistance_values.max <= unit_helper(min_expected_r_value_ip, 'ft^2*h*R/Btu', 'm^2*K/W')
|
157
|
-
runner.registerWarning("Construction '#{exterior_surface_construction.name}' does not appear to have an insulation layer and was not altered.")
|
158
|
-
else
|
159
|
-
# clone the construction
|
160
|
-
final_construction = exterior_surface_construction.clone(model)
|
161
|
-
final_construction = final_construction.to_Construction.get
|
162
|
-
final_construction.setName("#{exterior_surface_construction.name} adj exterior wall insulation")
|
163
|
-
final_constructions_array << final_construction
|
164
|
-
|
165
|
-
# add construction object if it didnt exist to start with
|
166
|
-
|
167
|
-
# push to hashes
|
168
|
-
constructions_hash_old_new[exterior_surface_construction.name.to_s] = final_construction
|
169
|
-
constructions_hash_new_old[final_construction] = exterior_surface_construction # push the object to hash key vs. name
|
170
|
-
|
171
|
-
# find already cloned insulation material and link to construction
|
172
|
-
target_material = max_thermal_resistance_material
|
173
|
-
found_material = false
|
174
|
-
materials_hash.each do |orig, new|
|
175
|
-
if target_material.name.to_s == orig
|
176
|
-
new_material = new
|
177
|
-
materials_hash[max_thermal_resistance_material.name.to_s] = new_material
|
178
|
-
final_construction.eraseLayer(max_thermal_resistance_material_index)
|
179
|
-
final_construction.insertLayer(max_thermal_resistance_material_index, new_material)
|
180
|
-
found_material = true
|
181
|
-
end
|
182
|
-
end
|
183
|
-
|
184
|
-
# clone and edit insulation material and link to construction
|
185
|
-
if found_material == false
|
186
|
-
new_material = max_thermal_resistance_material.clone(model)
|
187
|
-
new_material = new_material.to_OpaqueMaterial.get
|
188
|
-
new_material.setName("#{max_thermal_resistance_material.name}_R-value #{r_value}% increase")
|
189
|
-
materials_hash[max_thermal_resistance_material.name.to_s] = new_material
|
190
|
-
final_construction.eraseLayer(max_thermal_resistance_material_index)
|
191
|
-
final_construction.insertLayer(max_thermal_resistance_material_index, new_material)
|
192
|
-
runner.registerInfo("For construction'#{final_construction.name}', material'#{new_material.name}' was altered.")
|
193
|
-
|
194
|
-
# edit insulation material
|
195
|
-
new_material_matt = new_material.to_Material
|
196
|
-
if !new_material_matt.empty?
|
197
|
-
starting_thickness = new_material_matt.get.thickness
|
198
|
-
target_thickness = starting_thickness * (1 + r_value / 100)
|
199
|
-
final_thickness = new_material_matt.get.setThickness(target_thickness)
|
200
|
-
end
|
201
|
-
new_material_massless = new_material.to_MasslessOpaqueMaterial
|
202
|
-
if !new_material_massless.empty?
|
203
|
-
starting_thermal_resistance = new_material_massless.get.thermalResistance
|
204
|
-
final_thermal_resistance = new_material_massless.get.setThermalResistance(starting_thermal_resistance * (1 + r_value / 100))
|
205
|
-
end
|
206
|
-
new_material_airgap = new_material.to_AirGap
|
207
|
-
if !new_material_airgap.empty?
|
208
|
-
starting_thermal_resistance = new_material_airgap.get.thermalResistance
|
209
|
-
final_thermal_resistance = new_material_airgap.get.setThermalResistance(starting_thermal_resistance * (1 + r_value / 100))
|
210
|
-
end
|
211
|
-
end
|
212
|
-
end
|
213
|
-
end
|
214
|
-
|
215
|
-
# loop through construction sets used in the model
|
216
|
-
default_construction_sets = model.getDefaultConstructionSets
|
217
|
-
default_construction_sets.each do |default_construction_set|
|
218
|
-
if default_construction_set.directUseCount > 0
|
219
|
-
default_surface_const_set = default_construction_set.defaultExteriorSurfaceConstructions
|
220
|
-
if !default_surface_const_set.empty?
|
221
|
-
starting_construction = default_surface_const_set.get.wallConstruction
|
222
|
-
|
223
|
-
# creating new default construction set
|
224
|
-
new_default_construction_set = default_construction_set.clone(model)
|
225
|
-
new_default_construction_set = new_default_construction_set.to_DefaultConstructionSet.get
|
226
|
-
new_default_construction_set.setName("#{default_construction_set.name} adj exterior wall insulation")
|
227
|
-
|
228
|
-
# create new surface set and link to construction set
|
229
|
-
new_default_surface_const_set = default_surface_const_set.get.clone(model)
|
230
|
-
new_default_surface_const_set = new_default_surface_const_set.to_DefaultSurfaceConstructions.get
|
231
|
-
new_default_surface_const_set.setName("#{default_surface_const_set.get.name} adj exterior wall insulation")
|
232
|
-
new_default_construction_set.setDefaultExteriorSurfaceConstructions(new_default_surface_const_set)
|
233
|
-
|
234
|
-
# use the hash to find the proper construction and link to new_default_surface_const_set
|
235
|
-
target_const = new_default_surface_const_set.wallConstruction
|
236
|
-
if !target_const.empty?
|
237
|
-
target_const = target_const.get.name.to_s
|
238
|
-
found_const_flag = false
|
239
|
-
constructions_hash_old_new.each do |orig, new|
|
240
|
-
if target_const == orig
|
241
|
-
final_construction = new
|
242
|
-
new_default_surface_const_set.setWallConstruction(final_construction)
|
243
|
-
found_const_flag = true
|
244
|
-
end
|
245
|
-
end
|
246
|
-
if found_const_flag == false # this should never happen but is just an extra test in case something goes wrong with the measure code
|
247
|
-
runner.registerWarning("Measure couldn't find the construction named '#{target_const}' in the exterior surface hash.")
|
248
|
-
end
|
249
|
-
end
|
250
|
-
|
251
|
-
# swap all uses of the old construction set for the new
|
252
|
-
construction_set_sources = default_construction_set.sources
|
253
|
-
construction_set_sources.each do |construction_set_source|
|
254
|
-
building_source = construction_set_source.to_Building
|
255
|
-
# if statement for each type of object than can use a DefaultConstructionSet
|
256
|
-
if !building_source.empty?
|
257
|
-
building_source = building_source.get
|
258
|
-
building_source.setDefaultConstructionSet(new_default_construction_set)
|
259
|
-
end
|
260
|
-
building_story_source = construction_set_source.to_BuildingStory
|
261
|
-
if !building_story_source.empty?
|
262
|
-
building_story_source = building_story_source.get
|
263
|
-
building_story_source.setDefaultConstructionSet(new_default_construction_set)
|
264
|
-
end
|
265
|
-
space_type_source = construction_set_source.to_SpaceType
|
266
|
-
if !space_type_source.empty?
|
267
|
-
space_type_source = space_type_source.get
|
268
|
-
space_type_source.setDefaultConstructionSet(new_default_construction_set)
|
269
|
-
end
|
270
|
-
space_source = construction_set_source.to_Space
|
271
|
-
if !space_source.empty?
|
272
|
-
space_source = space_source.get
|
273
|
-
space_source.setDefaultConstructionSet(new_default_construction_set)
|
274
|
-
end
|
275
|
-
end
|
276
|
-
|
277
|
-
end
|
278
|
-
end
|
279
|
-
end
|
280
|
-
|
281
|
-
# link cloned and edited constructions for surfaces with hard assigned constructions
|
282
|
-
exterior_surfaces.each do |exterior_surface|
|
283
|
-
if !exterior_surface.isConstructionDefaulted && !exterior_surface.construction.empty?
|
284
|
-
|
285
|
-
# use the hash to find the proper construction and link to surface
|
286
|
-
target_const = exterior_surface.construction
|
287
|
-
if !target_const.empty?
|
288
|
-
target_const = target_const.get.name.to_s
|
289
|
-
constructions_hash_old_new.each do |orig, new|
|
290
|
-
if target_const == orig
|
291
|
-
final_construction = new
|
292
|
-
exterior_surface.setConstruction(final_construction)
|
293
|
-
end
|
294
|
-
end
|
295
|
-
end
|
296
|
-
|
297
|
-
end
|
298
|
-
end
|
299
|
-
|
300
|
-
# report strings for final condition
|
301
|
-
final_string = [] # not all exterior surface constructions, but only new ones made. If exterior surface didn't have insulation and was not altered we don't want to show it
|
302
|
-
affected_area_si = 0
|
303
|
-
final_constructions_array.each do |final_construction|
|
304
|
-
# unit conversion of exterior surface insulation from SI units (M^2*K/W) to IP units (ft^2*h*R/Btu)
|
305
|
-
final_conductance_ip = unit_helper(1 / final_construction.thermalConductance.to_f, 'm^2*K/W', 'ft^2*h*R/Btu')
|
306
|
-
final_string << "#{final_construction.name} (R-#{(format '%.1f', final_conductance_ip)})"
|
307
|
-
affected_area_si += final_construction.getNetArea
|
308
|
-
end
|
309
|
-
|
310
|
-
# add not applicable test if there were exterior surface constructions but none of them were altered (already enough insulation or doesn't look like insulated wall)
|
311
|
-
if affected_area_si == 0
|
312
|
-
runner.registerAsNotApplicable('No exterior walls were altered.')
|
313
|
-
return true
|
314
|
-
# affected_area_ip = affected_area_si
|
315
|
-
else
|
316
|
-
# ip construction area for reporting
|
317
|
-
affected_area_ip = unit_helper(affected_area_si, 'm^2', 'ft^2')
|
318
|
-
end
|
319
|
-
|
320
|
-
# report final condition
|
321
|
-
runner.registerFinalCondition("The existing insulation for exterior walls was increased by #{r_value}%. This was applied to #{neat_numbers(affected_area_ip, 0)} (ft^2) across #{final_string.size} exterior wall constructions: #{final_string.sort.join(', ')}.")
|
322
|
-
|
323
|
-
return true
|
324
|
-
end
|
325
|
-
end
|
326
|
-
|
327
|
-
# this allows the measure to be used by the application
|
328
|
-
IncreaseInsulationRValueForExteriorWallsByPercentage.new.registerWithApplication
|
@@ -1,98 +0,0 @@
|
|
1
|
-
<measure>
|
2
|
-
<schema_version>3.0</schema_version>
|
3
|
-
<name>increase_insulation_r_value_for_exterior_walls_by_percentage</name>
|
4
|
-
<uid>7508c563-22bd-49f4-b646-aac69b02a82d</uid>
|
5
|
-
<version_id>9ef20b5d-2bdd-417b-a5d9-b7f77d509133</version_id>
|
6
|
-
<version_modified>20200229T024318Z</version_modified>
|
7
|
-
<xml_checksum>EB1A0C08</xml_checksum>
|
8
|
-
<class_name>IncreaseInsulationRValueForExteriorWallsByPercentage</class_name>
|
9
|
-
<display_name>Increase R-value of Insulation for Exterior Walls By a Specified Percentage</display_name>
|
10
|
-
<description>Increase the R value of the insulation layer in wall constructinons by a percentage.</description>
|
11
|
-
<modeler_description>Insulation later is inferred by finding the existing layer with the highest thermal resistance.</modeler_description>
|
12
|
-
<arguments>
|
13
|
-
<argument>
|
14
|
-
<name>r_value</name>
|
15
|
-
<display_name>Percentage Increase of R-value for Exterior Wall Insulation.</display_name>
|
16
|
-
<type>Double</type>
|
17
|
-
<required>true</required>
|
18
|
-
<model_dependent>false</model_dependent>
|
19
|
-
<default_value>30</default_value>
|
20
|
-
</argument>
|
21
|
-
</arguments>
|
22
|
-
<outputs/>
|
23
|
-
<provenances/>
|
24
|
-
<tags>
|
25
|
-
<tag>Envelope.Opaque</tag>
|
26
|
-
</tags>
|
27
|
-
<attributes>
|
28
|
-
<attribute>
|
29
|
-
<name>Measure Function</name>
|
30
|
-
<value>Measure</value>
|
31
|
-
<datatype>string</datatype>
|
32
|
-
</attribute>
|
33
|
-
<attribute>
|
34
|
-
<name>Requires EnergyPlus Results</name>
|
35
|
-
<value>false</value>
|
36
|
-
<datatype>boolean</datatype>
|
37
|
-
</attribute>
|
38
|
-
<attribute>
|
39
|
-
<name>Measure Type</name>
|
40
|
-
<value>ModelMeasure</value>
|
41
|
-
<datatype>string</datatype>
|
42
|
-
</attribute>
|
43
|
-
<attribute>
|
44
|
-
<name>Uses SketchUp API</name>
|
45
|
-
<value>false</value>
|
46
|
-
<datatype>boolean</datatype>
|
47
|
-
</attribute>
|
48
|
-
</attributes>
|
49
|
-
<files>
|
50
|
-
<file>
|
51
|
-
<filename>EnvelopeAndLoadTestModel_01.osm</filename>
|
52
|
-
<filetype>osm</filetype>
|
53
|
-
<usage_type>test</usage_type>
|
54
|
-
<checksum>10AA8866</checksum>
|
55
|
-
</file>
|
56
|
-
<file>
|
57
|
-
<filename>ReverseTranslatedModel.osm</filename>
|
58
|
-
<filetype>osm</filetype>
|
59
|
-
<usage_type>test</usage_type>
|
60
|
-
<checksum>0B94403D</checksum>
|
61
|
-
</file>
|
62
|
-
<file>
|
63
|
-
<filename>README.md.erb</filename>
|
64
|
-
<filetype>erb</filetype>
|
65
|
-
<usage_type>readmeerb</usage_type>
|
66
|
-
<checksum>703C9964</checksum>
|
67
|
-
</file>
|
68
|
-
<file>
|
69
|
-
<filename>README.md</filename>
|
70
|
-
<filetype>md</filetype>
|
71
|
-
<usage_type>readme</usage_type>
|
72
|
-
<checksum>D4B90CE5</checksum>
|
73
|
-
</file>
|
74
|
-
<file>
|
75
|
-
<filename>LICENSE.md</filename>
|
76
|
-
<filetype>md</filetype>
|
77
|
-
<usage_type>license</usage_type>
|
78
|
-
<checksum>E0468DD6</checksum>
|
79
|
-
</file>
|
80
|
-
<file>
|
81
|
-
<version>
|
82
|
-
<software_program>OpenStudio</software_program>
|
83
|
-
<identifier>2.0.0</identifier>
|
84
|
-
<min_compatible>2.0.0</min_compatible>
|
85
|
-
</version>
|
86
|
-
<filename>measure.rb</filename>
|
87
|
-
<filetype>rb</filetype>
|
88
|
-
<usage_type>script</usage_type>
|
89
|
-
<checksum>478DC9B7</checksum>
|
90
|
-
</file>
|
91
|
-
<file>
|
92
|
-
<filename>IncreaseInsulationRValueForExteriorWalls_Test.rb</filename>
|
93
|
-
<filetype>rb</filetype>
|
94
|
-
<usage_type>test</usage_type>
|
95
|
-
<checksum>01E73CC1</checksum>
|
96
|
-
</file>
|
97
|
-
</files>
|
98
|
-
</measure>
|
@@ -1,27 +0,0 @@
|
|
1
|
-
OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC. All rights reserved.
|
2
|
-
|
3
|
-
Redistribution and use in source and binary forms, with or without modification, are permitted
|
4
|
-
provided that the following conditions are met:
|
5
|
-
|
6
|
-
(1) Redistributions of source code must retain the above copyright notice, this list of conditions
|
7
|
-
and the following disclaimer.
|
8
|
-
|
9
|
-
(2) Redistributions in binary form must reproduce the above copyright notice, this list of conditions
|
10
|
-
and the following disclaimer in the documentation and/or other materials provided with the distribution.
|
11
|
-
|
12
|
-
(3) Neither the name of the copyright holder nor the names of any contributors may be used to endorse
|
13
|
-
or promote products derived from this software without specific prior written permission from the
|
14
|
-
respective party.
|
15
|
-
|
16
|
-
(4) Other than as required in clauses (1) and (2), distributions in any form of modifications or other
|
17
|
-
derivative works may not use the "OpenStudio" trademark, "OS", "os", or any other confusingly similar
|
18
|
-
designation without specific prior written permission from Alliance for Sustainable Energy, LLC.
|
19
|
-
|
20
|
-
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED
|
21
|
-
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
|
22
|
-
PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER, THE UNITED STATES GOVERNMENT,
|
23
|
-
OR ANY CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
24
|
-
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,
|
25
|
-
OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
|
26
|
-
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
|
27
|
-
SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
@@ -1,64 +0,0 @@
|
|
1
|
-
|
2
|
-
|
3
|
-
###### (Automatically generated documentation)
|
4
|
-
|
5
|
-
# Increase R-value of Insulation for Roofs to a Specific Value
|
6
|
-
|
7
|
-
## Description
|
8
|
-
|
9
|
-
|
10
|
-
## Modeler Description
|
11
|
-
|
12
|
-
|
13
|
-
## Measure Type
|
14
|
-
ModelMeasure
|
15
|
-
|
16
|
-
## Taxonomy
|
17
|
-
|
18
|
-
|
19
|
-
## Arguments
|
20
|
-
|
21
|
-
|
22
|
-
### Insulation R-value (ft^2*h*R/Btu).
|
23
|
-
|
24
|
-
**Name:** r_value,
|
25
|
-
**Type:** Double,
|
26
|
-
**Units:** ,
|
27
|
-
**Required:** true,
|
28
|
-
**Model Dependent:** false
|
29
|
-
|
30
|
-
### Allow both increase and decrease in R-value to reach requested target?
|
31
|
-
|
32
|
-
**Name:** allow_reduction,
|
33
|
-
**Type:** Boolean,
|
34
|
-
**Units:** ,
|
35
|
-
**Required:** true,
|
36
|
-
**Model Dependent:** false
|
37
|
-
|
38
|
-
### Increase in Material and Installation Costs for Construction per Area Used ($/ft^2).
|
39
|
-
|
40
|
-
**Name:** material_cost_increase_ip,
|
41
|
-
**Type:** Double,
|
42
|
-
**Units:** ,
|
43
|
-
**Required:** true,
|
44
|
-
**Model Dependent:** false
|
45
|
-
|
46
|
-
### One Time Retrofit Cost to Add Insulation to Construction ($/ft^2).
|
47
|
-
|
48
|
-
**Name:** one_time_retrofit_cost_ip,
|
49
|
-
**Type:** Double,
|
50
|
-
**Units:** ,
|
51
|
-
**Required:** true,
|
52
|
-
**Model Dependent:** false
|
53
|
-
|
54
|
-
### Year to Incur One Time Retrofit Cost (whole years).
|
55
|
-
|
56
|
-
**Name:** years_until_retrofit_cost,
|
57
|
-
**Type:** Integer,
|
58
|
-
**Units:** ,
|
59
|
-
**Required:** true,
|
60
|
-
**Model Dependent:** false
|
61
|
-
|
62
|
-
|
63
|
-
|
64
|
-
|
@@ -1,42 +0,0 @@
|
|
1
|
-
<%#= README.md.erb is used to auto-generate README.md. %>
|
2
|
-
<%#= To manually maintain README.md throw away README.md.erb and manually edit README.md %>
|
3
|
-
###### (Automatically generated documentation)
|
4
|
-
|
5
|
-
# <%= name %>
|
6
|
-
|
7
|
-
## Description
|
8
|
-
<%= description %>
|
9
|
-
|
10
|
-
## Modeler Description
|
11
|
-
<%= modelerDescription %>
|
12
|
-
|
13
|
-
## Measure Type
|
14
|
-
<%= measureType %>
|
15
|
-
|
16
|
-
## Taxonomy
|
17
|
-
<%= taxonomy %>
|
18
|
-
|
19
|
-
## Arguments
|
20
|
-
|
21
|
-
<% arguments.each do |argument| %>
|
22
|
-
### <%= argument[:display_name] %>
|
23
|
-
<%= argument[:description] %>
|
24
|
-
**Name:** <%= argument[:name] %>,
|
25
|
-
**Type:** <%= argument[:type] %>,
|
26
|
-
**Units:** <%= argument[:units] %>,
|
27
|
-
**Required:** <%= argument[:required] %>,
|
28
|
-
**Model Dependent:** <%= argument[:model_dependent] %>
|
29
|
-
<% end %>
|
30
|
-
|
31
|
-
<% if arguments.size == 0 %>
|
32
|
-
<%= "This measure does not have any user arguments" %>
|
33
|
-
<% end %>
|
34
|
-
|
35
|
-
<% if outputs.size > 0 %>
|
36
|
-
## Outputs
|
37
|
-
<% output_names = [] %>
|
38
|
-
<% outputs.each do |output| %>
|
39
|
-
<% output_names << output[:display_name] %>
|
40
|
-
<% end %>
|
41
|
-
<%= output_names.join(", ") %>
|
42
|
-
<% end %>
|