openstudio-common-measures 0.3.0 → 0.3.1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/CHANGELOG.md +16 -0
- data/lib/openstudio/common_measures/version.rb +1 -1
- metadata +3 -63
- data/lib/measures/AddDaylightSensors/LICENSE.md +0 -27
- data/lib/measures/AddDaylightSensors/README.md +0 -136
- data/lib/measures/AddDaylightSensors/README.md.erb +0 -42
- data/lib/measures/AddDaylightSensors/measure.rb +0 -521
- data/lib/measures/AddDaylightSensors/measure.xml +0 -233
- data/lib/measures/EnableDemandControlledVentilation/LICENSE.md +0 -27
- data/lib/measures/EnableDemandControlledVentilation/README.md +0 -32
- data/lib/measures/EnableDemandControlledVentilation/README.md.erb +0 -42
- data/lib/measures/EnableDemandControlledVentilation/measure.rb +0 -154
- data/lib/measures/EnableDemandControlledVentilation/measure.xml +0 -99
- data/lib/measures/EnableEconomizerControl/LICENSE.md +0 -27
- data/lib/measures/EnableEconomizerControl/README.md +0 -48
- data/lib/measures/EnableEconomizerControl/README.md.erb +0 -42
- data/lib/measures/EnableEconomizerControl/measure.rb +0 -172
- data/lib/measures/EnableEconomizerControl/measure.xml +0 -124
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md +0 -64
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.rb +0 -422
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.xml +0 -150
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/README.md +0 -32
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/measure.rb +0 -328
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/measure.xml +0 -98
- data/lib/measures/IncreaseInsulationRValueForRoofs/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForRoofs/README.md +0 -64
- data/lib/measures/IncreaseInsulationRValueForRoofs/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForRoofs/measure.rb +0 -422
- data/lib/measures/IncreaseInsulationRValueForRoofs/measure.xml +0 -143
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/README.md +0 -32
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/measure.rb +0 -328
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/measure.xml +0 -98
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md +0 -97
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.rb +0 -450
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.xml +0 -186
- data/lib/measures/ReduceLightingLoadsByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceLightingLoadsByPercentage/README.md +0 -96
- data/lib/measures/ReduceLightingLoadsByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceLightingLoadsByPercentage/measure.rb +0 -513
- data/lib/measures/ReduceLightingLoadsByPercentage/measure.xml +0 -191
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md +0 -104
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.rb +0 -349
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.xml +0 -181
- data/lib/measures/ReduceVentilationByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceVentilationByPercentage/README.md +0 -40
- data/lib/measures/ReduceVentilationByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceVentilationByPercentage/measure.rb +0 -291
- data/lib/measures/ReduceVentilationByPercentage/measure.xml +0 -96
- data/lib/measures/create_variable_speed_rtu/LICENSE.md +0 -27
- data/lib/measures/create_variable_speed_rtu/README.md +0 -120
- data/lib/measures/create_variable_speed_rtu/README.md.erb +0 -42
- data/lib/measures/create_variable_speed_rtu/measure.rb +0 -539
- data/lib/measures/create_variable_speed_rtu/measure.xml +0 -207
@@ -1,27 +0,0 @@
|
|
1
|
-
OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC. All rights reserved.
|
2
|
-
|
3
|
-
Redistribution and use in source and binary forms, with or without modification, are permitted
|
4
|
-
provided that the following conditions are met:
|
5
|
-
|
6
|
-
(1) Redistributions of source code must retain the above copyright notice, this list of conditions
|
7
|
-
and the following disclaimer.
|
8
|
-
|
9
|
-
(2) Redistributions in binary form must reproduce the above copyright notice, this list of conditions
|
10
|
-
and the following disclaimer in the documentation and/or other materials provided with the distribution.
|
11
|
-
|
12
|
-
(3) Neither the name of the copyright holder nor the names of any contributors may be used to endorse
|
13
|
-
or promote products derived from this software without specific prior written permission from the
|
14
|
-
respective party.
|
15
|
-
|
16
|
-
(4) Other than as required in clauses (1) and (2), distributions in any form of modifications or other
|
17
|
-
derivative works may not use the "OpenStudio" trademark, "OS", "os", or any other confusingly similar
|
18
|
-
designation without specific prior written permission from Alliance for Sustainable Energy, LLC.
|
19
|
-
|
20
|
-
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED
|
21
|
-
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
|
22
|
-
PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER, THE UNITED STATES GOVERNMENT,
|
23
|
-
OR ANY CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
24
|
-
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,
|
25
|
-
OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
|
26
|
-
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
|
27
|
-
SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
@@ -1,64 +0,0 @@
|
|
1
|
-
|
2
|
-
|
3
|
-
###### (Automatically generated documentation)
|
4
|
-
|
5
|
-
# Increase R-value of Insulation for Exterior Walls to a Specific Value
|
6
|
-
|
7
|
-
## Description
|
8
|
-
|
9
|
-
|
10
|
-
## Modeler Description
|
11
|
-
|
12
|
-
|
13
|
-
## Measure Type
|
14
|
-
ModelMeasure
|
15
|
-
|
16
|
-
## Taxonomy
|
17
|
-
|
18
|
-
|
19
|
-
## Arguments
|
20
|
-
|
21
|
-
|
22
|
-
### Insulation R-value (ft^2*h*R/Btu).
|
23
|
-
|
24
|
-
**Name:** r_value,
|
25
|
-
**Type:** Double,
|
26
|
-
**Units:** ,
|
27
|
-
**Required:** true,
|
28
|
-
**Model Dependent:** false
|
29
|
-
|
30
|
-
### Allow both increase and decrease in R-value to reach requested target?
|
31
|
-
|
32
|
-
**Name:** allow_reduction,
|
33
|
-
**Type:** Boolean,
|
34
|
-
**Units:** ,
|
35
|
-
**Required:** true,
|
36
|
-
**Model Dependent:** false
|
37
|
-
|
38
|
-
### Increase in Material and Installation Costs for Construction per Area Used ($/ft^2).
|
39
|
-
|
40
|
-
**Name:** material_cost_increase_ip,
|
41
|
-
**Type:** Double,
|
42
|
-
**Units:** ,
|
43
|
-
**Required:** true,
|
44
|
-
**Model Dependent:** false
|
45
|
-
|
46
|
-
### One Time Retrofit Cost to Add Insulation to Construction ($/ft^2).
|
47
|
-
|
48
|
-
**Name:** one_time_retrofit_cost_ip,
|
49
|
-
**Type:** Double,
|
50
|
-
**Units:** ,
|
51
|
-
**Required:** true,
|
52
|
-
**Model Dependent:** false
|
53
|
-
|
54
|
-
### Year to Incur One Time Retrofit Cost (whole years).
|
55
|
-
|
56
|
-
**Name:** years_until_retrofit_cost,
|
57
|
-
**Type:** Integer,
|
58
|
-
**Units:** ,
|
59
|
-
**Required:** true,
|
60
|
-
**Model Dependent:** false
|
61
|
-
|
62
|
-
|
63
|
-
|
64
|
-
|
@@ -1,42 +0,0 @@
|
|
1
|
-
<%#= README.md.erb is used to auto-generate README.md. %>
|
2
|
-
<%#= To manually maintain README.md throw away README.md.erb and manually edit README.md %>
|
3
|
-
###### (Automatically generated documentation)
|
4
|
-
|
5
|
-
# <%= name %>
|
6
|
-
|
7
|
-
## Description
|
8
|
-
<%= description %>
|
9
|
-
|
10
|
-
## Modeler Description
|
11
|
-
<%= modelerDescription %>
|
12
|
-
|
13
|
-
## Measure Type
|
14
|
-
<%= measureType %>
|
15
|
-
|
16
|
-
## Taxonomy
|
17
|
-
<%= taxonomy %>
|
18
|
-
|
19
|
-
## Arguments
|
20
|
-
|
21
|
-
<% arguments.each do |argument| %>
|
22
|
-
### <%= argument[:display_name] %>
|
23
|
-
<%= argument[:description] %>
|
24
|
-
**Name:** <%= argument[:name] %>,
|
25
|
-
**Type:** <%= argument[:type] %>,
|
26
|
-
**Units:** <%= argument[:units] %>,
|
27
|
-
**Required:** <%= argument[:required] %>,
|
28
|
-
**Model Dependent:** <%= argument[:model_dependent] %>
|
29
|
-
<% end %>
|
30
|
-
|
31
|
-
<% if arguments.size == 0 %>
|
32
|
-
<%= "This measure does not have any user arguments" %>
|
33
|
-
<% end %>
|
34
|
-
|
35
|
-
<% if outputs.size > 0 %>
|
36
|
-
## Outputs
|
37
|
-
<% output_names = [] %>
|
38
|
-
<% outputs.each do |output| %>
|
39
|
-
<% output_names << output[:display_name] %>
|
40
|
-
<% end %>
|
41
|
-
<%= output_names.join(", ") %>
|
42
|
-
<% end %>
|
@@ -1,422 +0,0 @@
|
|
1
|
-
# *******************************************************************************
|
2
|
-
# OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC.
|
3
|
-
# All rights reserved.
|
4
|
-
# Redistribution and use in source and binary forms, with or without
|
5
|
-
# modification, are permitted provided that the following conditions are met:
|
6
|
-
#
|
7
|
-
# (1) Redistributions of source code must retain the above copyright notice,
|
8
|
-
# this list of conditions and the following disclaimer.
|
9
|
-
#
|
10
|
-
# (2) Redistributions in binary form must reproduce the above copyright notice,
|
11
|
-
# this list of conditions and the following disclaimer in the documentation
|
12
|
-
# and/or other materials provided with the distribution.
|
13
|
-
#
|
14
|
-
# (3) Neither the name of the copyright holder nor the names of any contributors
|
15
|
-
# may be used to endorse or promote products derived from this software without
|
16
|
-
# specific prior written permission from the respective party.
|
17
|
-
#
|
18
|
-
# (4) Other than as required in clauses (1) and (2), distributions in any form
|
19
|
-
# of modifications or other derivative works may not use the "OpenStudio"
|
20
|
-
# trademark, "OS", "os", or any other confusingly similar designation without
|
21
|
-
# specific prior written permission from Alliance for Sustainable Energy, LLC.
|
22
|
-
#
|
23
|
-
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS
|
24
|
-
# "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
|
25
|
-
# THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
26
|
-
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE
|
27
|
-
# UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF
|
28
|
-
# THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
|
29
|
-
# EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT
|
30
|
-
# OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
|
31
|
-
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
|
32
|
-
# STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
33
|
-
# OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
34
|
-
# *******************************************************************************
|
35
|
-
|
36
|
-
# start the measure
|
37
|
-
class IncreaseInsulationRValueForExteriorWalls < OpenStudio::Measure::ModelMeasure
|
38
|
-
# define the name that a user will see
|
39
|
-
def name
|
40
|
-
return 'Increase R-value of Insulation for Exterior Walls to a Specific Value'
|
41
|
-
end
|
42
|
-
|
43
|
-
# define the arguments that the user will input
|
44
|
-
def arguments(model)
|
45
|
-
args = OpenStudio::Measure::OSArgumentVector.new
|
46
|
-
|
47
|
-
# make an argument insulation R-value
|
48
|
-
r_value = OpenStudio::Measure::OSArgument.makeDoubleArgument('r_value', true)
|
49
|
-
r_value.setDisplayName('Insulation R-value (ft^2*h*R/Btu).')
|
50
|
-
r_value.setDefaultValue(13.0)
|
51
|
-
args << r_value
|
52
|
-
|
53
|
-
# make bool argument to allow both increase and decrease in R value
|
54
|
-
allow_reduction = OpenStudio::Measure::OSArgument.makeBoolArgument('allow_reduction', true)
|
55
|
-
allow_reduction.setDisplayName('Allow both increase and decrease in R-value to reach requested target?')
|
56
|
-
allow_reduction.setDefaultValue(false)
|
57
|
-
args << allow_reduction
|
58
|
-
|
59
|
-
# make an argument for material and installation cost
|
60
|
-
material_cost_increase_ip = OpenStudio::Measure::OSArgument.makeDoubleArgument('material_cost_increase_ip', true)
|
61
|
-
material_cost_increase_ip.setDisplayName('Increase in Material and Installation Costs for Construction per Area Used ($/ft^2).')
|
62
|
-
material_cost_increase_ip.setDefaultValue(0.0)
|
63
|
-
args << material_cost_increase_ip
|
64
|
-
|
65
|
-
# make an argument for demolition cost
|
66
|
-
one_time_retrofit_cost_ip = OpenStudio::Measure::OSArgument.makeDoubleArgument('one_time_retrofit_cost_ip', true)
|
67
|
-
one_time_retrofit_cost_ip.setDisplayName('One Time Retrofit Cost to Add Insulation to Construction ($/ft^2).')
|
68
|
-
one_time_retrofit_cost_ip.setDefaultValue(0.0)
|
69
|
-
args << one_time_retrofit_cost_ip
|
70
|
-
|
71
|
-
# make an argument for duration in years until costs start
|
72
|
-
years_until_retrofit_cost = OpenStudio::Measure::OSArgument.makeIntegerArgument('years_until_retrofit_cost', true)
|
73
|
-
years_until_retrofit_cost.setDisplayName('Year to Incur One Time Retrofit Cost (whole years).')
|
74
|
-
years_until_retrofit_cost.setDefaultValue(0)
|
75
|
-
args << years_until_retrofit_cost
|
76
|
-
|
77
|
-
return args
|
78
|
-
end
|
79
|
-
|
80
|
-
# define what happens when the measure is run
|
81
|
-
def run(model, runner, user_arguments)
|
82
|
-
super(model, runner, user_arguments)
|
83
|
-
|
84
|
-
# use the built-in error checking
|
85
|
-
if !runner.validateUserArguments(arguments(model), user_arguments)
|
86
|
-
return false
|
87
|
-
end
|
88
|
-
|
89
|
-
# assign the user inputs to variables
|
90
|
-
r_value = runner.getDoubleArgumentValue('r_value', user_arguments)
|
91
|
-
allow_reduction = runner.getBoolArgumentValue('allow_reduction', user_arguments)
|
92
|
-
material_cost_increase_ip = runner.getDoubleArgumentValue('material_cost_increase_ip', user_arguments)
|
93
|
-
one_time_retrofit_cost_ip = runner.getDoubleArgumentValue('one_time_retrofit_cost_ip', user_arguments)
|
94
|
-
years_until_retrofit_cost = runner.getIntegerArgumentValue('years_until_retrofit_cost', user_arguments)
|
95
|
-
|
96
|
-
# set limit for minimum insulation. This is used to limit input and for inferring insulation layer in construction.
|
97
|
-
min_expected_r_value_ip = 1 # ip units
|
98
|
-
|
99
|
-
# check the R-value for reasonableness
|
100
|
-
if (r_value < 0) || (r_value > 500)
|
101
|
-
runner.registerError("The requested wall insulation R-value of #{r_value} ft^2*h*R/Btu was above the measure limit.")
|
102
|
-
return false
|
103
|
-
elsif r_value > 40
|
104
|
-
runner.registerWarning("The requested wall insulation R-value of #{r_value} ft^2*h*R/Btu is abnormally high.")
|
105
|
-
elsif r_value < min_expected_r_value_ip
|
106
|
-
runner.registerWarning("The requested wall insulation R-value of #{r_value} ft^2*h*R/Btu is abnormally low.")
|
107
|
-
end
|
108
|
-
|
109
|
-
# check lifecycle arguments for reasonableness
|
110
|
-
if (years_until_retrofit_cost < 0) && (years_until_retrofit_cost > 100)
|
111
|
-
runner.registerError('Year to incur one time retrofit cost should be a non-negative integer less than or equal to 100.')
|
112
|
-
end
|
113
|
-
|
114
|
-
# short def to make numbers pretty (converts 4125001.25641 to 4,125,001.26 or 4,125,001). The definition be called through this measure
|
115
|
-
def neat_numbers(number, roundto = 2) # round to 0 or 2)
|
116
|
-
if roundto == 2
|
117
|
-
number = format '%.2f', number
|
118
|
-
else
|
119
|
-
number = number.round
|
120
|
-
end
|
121
|
-
# regex to add commas
|
122
|
-
number.to_s.reverse.gsub(/([0-9]{3}(?=([0-9])))/, '\\1,').reverse
|
123
|
-
end
|
124
|
-
|
125
|
-
# helper to make it easier to do unit conversions on the fly
|
126
|
-
def unit_helper(number, from_unit_string, to_unit_string)
|
127
|
-
converted_number = OpenStudio.convert(OpenStudio::Quantity.new(number, OpenStudio.createUnit(from_unit_string).get), OpenStudio.createUnit(to_unit_string).get).get.value
|
128
|
-
end
|
129
|
-
|
130
|
-
# convert r_value and material_cost to si for future use
|
131
|
-
r_value_si = unit_helper(r_value, 'ft^2*h*R/Btu', 'm^2*K/W')
|
132
|
-
material_cost_increase_si = unit_helper(material_cost_increase_ip, '1/ft^2', '1/m^2')
|
133
|
-
|
134
|
-
# create an array of exterior walls and find range of starting construction R-value (not just insulation layer)
|
135
|
-
surfaces = model.getSurfaces
|
136
|
-
exterior_surfaces = []
|
137
|
-
exterior_surface_constructions = []
|
138
|
-
exterior_surface_construction_names = []
|
139
|
-
ext_wall_resistance = []
|
140
|
-
surfaces.each do |surface|
|
141
|
-
if (surface.outsideBoundaryCondition == 'Outdoors') && (surface.surfaceType == 'Wall')
|
142
|
-
exterior_surfaces << surface
|
143
|
-
ext_wall_const = surface.construction.get
|
144
|
-
# only add construction if it hasn't been added yet
|
145
|
-
if !exterior_surface_construction_names.include?(ext_wall_const.name.to_s)
|
146
|
-
exterior_surface_constructions << ext_wall_const.to_Construction.get
|
147
|
-
end
|
148
|
-
exterior_surface_construction_names << ext_wall_const.name.to_s
|
149
|
-
ext_wall_resistance << 1 / ext_wall_const.thermalConductance.to_f
|
150
|
-
end
|
151
|
-
end
|
152
|
-
|
153
|
-
# nothing will be done if there are no exterior surfaces
|
154
|
-
if exterior_surfaces.empty?
|
155
|
-
runner.registerAsNotApplicable('Model does not have any exterior walls.')
|
156
|
-
return true
|
157
|
-
end
|
158
|
-
|
159
|
-
# report strings for initial condition
|
160
|
-
initial_string = []
|
161
|
-
exterior_surface_constructions.uniq.each do |exterior_surface_construction|
|
162
|
-
# unit conversion of wall insulation from SI units (M^2*K/W) to IP units (ft^2*h*R/Btu)
|
163
|
-
initial_conductance_ip = unit_helper(1 / exterior_surface_construction.thermalConductance.to_f, 'm^2*K/W', 'ft^2*h*R/Btu')
|
164
|
-
initial_string << "#{exterior_surface_construction.name} (R-#{(format '%.1f', initial_conductance_ip)})"
|
165
|
-
end
|
166
|
-
runner.registerInitialCondition("The building had #{initial_string.size} exterior wall constructions: #{initial_string.sort.join(', ')}.")
|
167
|
-
|
168
|
-
# hashes to track constructions and materials made by the measure, to avoid duplicates
|
169
|
-
constructions_hash_old_new = {}
|
170
|
-
constructions_hash_new_old = {} # used to get netArea of new construction and then cost objects of construction it replaced
|
171
|
-
materials_hash = {}
|
172
|
-
|
173
|
-
# array and counter for new constructions that are made, used for reporting final condition
|
174
|
-
final_constructions_array = []
|
175
|
-
|
176
|
-
# loop through all constructions and materials used on exterior walls, edit and clone
|
177
|
-
exterior_surface_constructions.each do |exterior_surface_construction|
|
178
|
-
construction_layers = exterior_surface_construction.layers
|
179
|
-
max_thermal_resistance_material = ''
|
180
|
-
max_thermal_resistance_material_index = ''
|
181
|
-
materials_in_construction = construction_layers.map.with_index do |layer, i|
|
182
|
-
{ 'name' => layer.name.to_s,
|
183
|
-
'index' => i,
|
184
|
-
'nomass' => !layer.to_MasslessOpaqueMaterial.empty?,
|
185
|
-
'r_value' => layer.to_OpaqueMaterial.get.thermalResistance,
|
186
|
-
'mat' => layer }
|
187
|
-
end
|
188
|
-
|
189
|
-
no_mass_materials = materials_in_construction.select { |mat| mat['nomass'] == true }
|
190
|
-
# measure will select the no mass material with the highest r-value as the insulation layer
|
191
|
-
# if no mass materials are present, the measure will select the material with the highest r-value per inch
|
192
|
-
if !no_mass_materials.empty?
|
193
|
-
thermal_resistance_values = no_mass_materials.map { |mat| mat['r_value'] }
|
194
|
-
max_mat_hash = no_mass_materials.select { |mat| mat['r_value'] >= thermal_resistance_values.max }
|
195
|
-
else
|
196
|
-
thermal_resistance_per_thickness_values = materials_in_construction.map { |mat| mat['r_value'] / mat['mat'].thickness }
|
197
|
-
target_index = thermal_resistance_per_thickness_values.index(thermal_resistance_per_thickness_values.max)
|
198
|
-
max_mat_hash = materials_in_construction.select { |mat| mat['index'] == target_index }
|
199
|
-
thermal_resistance_values = materials_in_construction.map { |mat| mat['r_value'] }
|
200
|
-
end
|
201
|
-
max_thermal_resistance_material = max_mat_hash[0]['mat']
|
202
|
-
max_thermal_resistance_material_index = max_mat_hash[0]['index']
|
203
|
-
max_thermal_resistance = max_thermal_resistance_material.to_OpaqueMaterial.get.thermalResistance
|
204
|
-
|
205
|
-
if max_thermal_resistance <= unit_helper(min_expected_r_value_ip, 'ft^2*h*R/Btu', 'm^2*K/W')
|
206
|
-
runner.registerWarning("Construction '#{exterior_surface_construction.name}' does not appear to have an insulation layer and was not altered.")
|
207
|
-
elsif (max_thermal_resistance >= r_value_si) && !allow_reduction
|
208
|
-
runner.registerInfo("The insulation layer of construction #{exterior_surface_construction.name} exceeds the requested R-Value. It was not altered.")
|
209
|
-
else
|
210
|
-
# clone the construction
|
211
|
-
final_construction = exterior_surface_construction.clone(model)
|
212
|
-
final_construction = final_construction.to_Construction.get
|
213
|
-
final_construction.setName("#{exterior_surface_construction.name} adj ext wall insulation")
|
214
|
-
final_constructions_array << final_construction
|
215
|
-
|
216
|
-
# loop through lifecycle costs getting total costs under "Construction" or "Salvage" category and add to counter if occurs during year 0
|
217
|
-
const_LCCs = final_construction.lifeCycleCosts
|
218
|
-
cost_added = false
|
219
|
-
const_LCC_cat_const = false
|
220
|
-
updated_cost_si = 0
|
221
|
-
const_LCCs.each do |const_LCC|
|
222
|
-
if (const_LCC.category == 'Construction') && (material_cost_increase_si != 0)
|
223
|
-
const_LCC_cat_const = true # need this test to add proper lcc if it didn't exist to start with
|
224
|
-
# if multiple LCC objects associated with construction only adjust the cost of one of them.
|
225
|
-
if !cost_added
|
226
|
-
const_LCC.setCost(const_LCC.cost + material_cost_increase_si)
|
227
|
-
else
|
228
|
-
runner.registerInfo("More than one LifeCycleCost object with a category of Construction was associated with #{final_construction.name}. Cost was only adjusted for one of the LifeCycleCost objects.")
|
229
|
-
end
|
230
|
-
updated_cost_si += const_LCC.cost
|
231
|
-
end
|
232
|
-
end
|
233
|
-
|
234
|
-
if cost_added
|
235
|
-
runner.registerInfo("Adjusting material and installation cost for #{final_construction.name} to #{neat_numbers(unit_helper(updated_cost_si, '1/m^2', '1/ft^2'))} ($/ft^2).")
|
236
|
-
end
|
237
|
-
|
238
|
-
# add construction object if it didnt exist to start with and a cost increase was requested
|
239
|
-
if (const_LCC_cat_const == false) && (material_cost_increase_si != 0)
|
240
|
-
lcc_for_uncosted_const = OpenStudio::Model::LifeCycleCost.createLifeCycleCost('LCC_increase_insulation', final_construction, material_cost_increase_si, 'CostPerArea', 'Construction', 20, 0).get
|
241
|
-
runner.registerInfo("No material or installation costs existed for #{final_construction.name}. Created a new LifeCycleCost object with a material and installation cost of #{neat_numbers(unit_helper(lcc_for_uncosted_const.cost, '1/m^2', '1/ft^2'))} ($/ft^2). Assumed capitol cost in first year, an expected life of 20 years, and no O & M costs.")
|
242
|
-
end
|
243
|
-
|
244
|
-
# add one time cost if requested
|
245
|
-
if one_time_retrofit_cost_ip > 0
|
246
|
-
one_time_retrofit_cost_si = unit_helper(one_time_retrofit_cost_ip, '1/ft^2', '1/m^2')
|
247
|
-
lcc_retrofit_specific = OpenStudio::Model::LifeCycleCost.createLifeCycleCost('LCC_retrofit_specific', final_construction, one_time_retrofit_cost_si, 'CostPerArea', 'Construction', 0, years_until_retrofit_cost).get # using 0 for repeat period since one time cost.
|
248
|
-
runner.registerInfo("Adding one time cost of #{neat_numbers(unit_helper(lcc_retrofit_specific.cost, '1/m^2', '1/ft^2'))} ($/ft^2) related to retrofit of wall insulation.")
|
249
|
-
end
|
250
|
-
|
251
|
-
# push to hashes
|
252
|
-
constructions_hash_old_new[exterior_surface_construction.name.to_s] = final_construction
|
253
|
-
constructions_hash_new_old[final_construction] = exterior_surface_construction # push the object to hash key vs. name
|
254
|
-
|
255
|
-
# find already cloned insulation material and link to construction
|
256
|
-
target_material = max_thermal_resistance_material
|
257
|
-
found_material = false
|
258
|
-
materials_hash.each do |orig, new|
|
259
|
-
if target_material.name.to_s == orig
|
260
|
-
new_material = new
|
261
|
-
materials_hash[max_thermal_resistance_material.name.to_s] = new_material
|
262
|
-
final_construction.eraseLayer(max_thermal_resistance_material_index)
|
263
|
-
final_construction.insertLayer(max_thermal_resistance_material_index, new_material)
|
264
|
-
found_material = true
|
265
|
-
end
|
266
|
-
end
|
267
|
-
|
268
|
-
# clone and edit insulation material and link to construction
|
269
|
-
if found_material == false
|
270
|
-
new_material = max_thermal_resistance_material.clone(model)
|
271
|
-
new_material = new_material.to_OpaqueMaterial.get
|
272
|
-
new_material.setName("#{max_thermal_resistance_material.name}_R-value #{r_value} (ft^2*h*R/Btu)")
|
273
|
-
materials_hash[max_thermal_resistance_material.name.to_s] = new_material
|
274
|
-
final_construction.eraseLayer(max_thermal_resistance_material_index)
|
275
|
-
final_construction.insertLayer(max_thermal_resistance_material_index, new_material)
|
276
|
-
runner.registerInfo("For construction'#{final_construction.name}', material'#{new_material.name}' was altered.")
|
277
|
-
|
278
|
-
# edit insulation material
|
279
|
-
new_material_matt = new_material.to_Material
|
280
|
-
if !new_material_matt.empty?
|
281
|
-
starting_thickness = new_material_matt.get.thickness
|
282
|
-
target_thickness = starting_thickness * r_value_si / thermal_resistance_values.max
|
283
|
-
final_thickness = new_material_matt.get.setThickness(target_thickness)
|
284
|
-
end
|
285
|
-
new_material_massless = new_material.to_MasslessOpaqueMaterial
|
286
|
-
if !new_material_massless.empty?
|
287
|
-
final_thermal_resistance = new_material_massless.get.setThermalResistance(r_value_si)
|
288
|
-
end
|
289
|
-
new_material_airgap = new_material.to_AirGap
|
290
|
-
if !new_material_airgap.empty?
|
291
|
-
final_thermal_resistance = new_material_airgap.get.setThermalResistance(r_value_si)
|
292
|
-
end
|
293
|
-
end
|
294
|
-
end
|
295
|
-
end
|
296
|
-
|
297
|
-
# loop through construction sets used in the model
|
298
|
-
default_construction_sets = model.getDefaultConstructionSets
|
299
|
-
default_construction_sets.each do |default_construction_set|
|
300
|
-
if default_construction_set.directUseCount > 0
|
301
|
-
default_surface_const_set = default_construction_set.defaultExteriorSurfaceConstructions
|
302
|
-
if !default_surface_const_set.empty?
|
303
|
-
starting_construction = default_surface_const_set.get.wallConstruction
|
304
|
-
|
305
|
-
# creating new default construction set
|
306
|
-
new_default_construction_set = default_construction_set.clone(model)
|
307
|
-
new_default_construction_set = new_default_construction_set.to_DefaultConstructionSet.get
|
308
|
-
new_default_construction_set.setName("#{default_construction_set.name} adj ext wall insulation")
|
309
|
-
|
310
|
-
# create new surface set and link to construction set
|
311
|
-
new_default_surface_const_set = default_surface_const_set.get.clone(model)
|
312
|
-
new_default_surface_const_set = new_default_surface_const_set.to_DefaultSurfaceConstructions.get
|
313
|
-
new_default_surface_const_set.setName("#{default_surface_const_set.get.name} adj ext wall insulation")
|
314
|
-
new_default_construction_set.setDefaultExteriorSurfaceConstructions(new_default_surface_const_set)
|
315
|
-
|
316
|
-
# use the hash to find the proper construction and link to new_default_surface_const_set
|
317
|
-
target_const = new_default_surface_const_set.wallConstruction
|
318
|
-
if !target_const.empty?
|
319
|
-
target_const = target_const.get.name.to_s
|
320
|
-
found_const_flag = false
|
321
|
-
constructions_hash_old_new.each do |orig, new|
|
322
|
-
if target_const == orig
|
323
|
-
final_construction = new
|
324
|
-
new_default_surface_const_set.setWallConstruction(final_construction)
|
325
|
-
found_const_flag = true
|
326
|
-
end
|
327
|
-
end
|
328
|
-
if found_const_flag == false # this should never happen but is just an extra test in case something goes wrong with the measure code
|
329
|
-
runner.registerWarning("Measure couldn't find the construction named '#{target_const}' in the exterior surface hash.")
|
330
|
-
end
|
331
|
-
end
|
332
|
-
|
333
|
-
# swap all uses of the old construction set for the new
|
334
|
-
construction_set_sources = default_construction_set.sources
|
335
|
-
construction_set_sources.each do |construction_set_source|
|
336
|
-
building_source = construction_set_source.to_Building
|
337
|
-
# if statement for each type of object than can use a DefaultConstructionSet
|
338
|
-
if !building_source.empty?
|
339
|
-
building_source = building_source.get
|
340
|
-
building_source.setDefaultConstructionSet(new_default_construction_set)
|
341
|
-
end
|
342
|
-
building_story_source = construction_set_source.to_BuildingStory
|
343
|
-
if !building_story_source.empty?
|
344
|
-
building_story_source = building_story_source.get
|
345
|
-
building_story_source.setDefaultConstructionSet(new_default_construction_set)
|
346
|
-
end
|
347
|
-
space_type_source = construction_set_source.to_SpaceType
|
348
|
-
if !space_type_source.empty?
|
349
|
-
space_type_source = space_type_source.get
|
350
|
-
space_type_source.setDefaultConstructionSet(new_default_construction_set)
|
351
|
-
end
|
352
|
-
space_source = construction_set_source.to_Space
|
353
|
-
if !space_source.empty?
|
354
|
-
space_source = space_source.get
|
355
|
-
space_source.setDefaultConstructionSet(new_default_construction_set)
|
356
|
-
end
|
357
|
-
end
|
358
|
-
|
359
|
-
end
|
360
|
-
end
|
361
|
-
end
|
362
|
-
|
363
|
-
# link cloned and edited constructions for surfaces with hard assigned constructions
|
364
|
-
exterior_surfaces.each do |exterior_surface|
|
365
|
-
if !exterior_surface.isConstructionDefaulted && !exterior_surface.construction.empty?
|
366
|
-
|
367
|
-
# use the hash to find the proper construction and link to surface
|
368
|
-
target_const = exterior_surface.construction
|
369
|
-
if !target_const.empty?
|
370
|
-
target_const = target_const.get.name.to_s
|
371
|
-
constructions_hash_old_new.each do |orig, new|
|
372
|
-
if target_const == orig
|
373
|
-
final_construction = new
|
374
|
-
exterior_surface.setConstruction(final_construction)
|
375
|
-
end
|
376
|
-
end
|
377
|
-
end
|
378
|
-
|
379
|
-
end
|
380
|
-
end
|
381
|
-
|
382
|
-
# report strings for final condition
|
383
|
-
final_string = [] # not all exterior wall constructions, but only new ones made. If wall didn't have insulation and was not altered we don't want to show it
|
384
|
-
affected_area_si = 0
|
385
|
-
totalCost_of_affected_area = 0
|
386
|
-
yr0_capital_totalCosts = 0
|
387
|
-
final_constructions_array.each do |final_construction|
|
388
|
-
# unit conversion of wall insulation from SI units (M^2*K/W) to IP units (ft^2*h*R/Btu)
|
389
|
-
final_conductance_ip = unit_helper(1 / final_construction.thermalConductance.to_f, 'm^2*K/W', 'ft^2*h*R/Btu')
|
390
|
-
final_string << "#{final_construction.name} (R-#{(format '%.1f', final_conductance_ip)})"
|
391
|
-
affected_area_si += final_construction.getNetArea
|
392
|
-
|
393
|
-
# loop through lifecycle costs getting total costs under "Construction" or "Salvage" category and add to counter if occurs during year 0
|
394
|
-
const_LCCs = final_construction.lifeCycleCosts
|
395
|
-
const_LCCs.each do |const_LCC|
|
396
|
-
if (const_LCC.category == 'Construction') || (const_LCC.category == 'Salvage')
|
397
|
-
if const_LCC.yearsFromStart == 0
|
398
|
-
yr0_capital_totalCosts += const_LCC.totalCost
|
399
|
-
end
|
400
|
-
end
|
401
|
-
end
|
402
|
-
end
|
403
|
-
|
404
|
-
# add not applicable test if there were exterior roof constructions but non of them were altered (already enough insulation or doesn't look like insulated wall)
|
405
|
-
if affected_area_si == 0
|
406
|
-
runner.registerAsNotApplicable('No exterior walls were altered.')
|
407
|
-
return true
|
408
|
-
# affected_area_ip = affected_area_si
|
409
|
-
else
|
410
|
-
# ip construction area for reporting
|
411
|
-
affected_area_ip = unit_helper(affected_area_si, 'm^2', 'ft^2')
|
412
|
-
end
|
413
|
-
|
414
|
-
# report final condition
|
415
|
-
runner.registerFinalCondition("The existing insulation for exterior walls was set to R-#{r_value}. This was accomplished for an initial cost of #{one_time_retrofit_cost_ip} ($/sf) and an increase of #{material_cost_increase_ip} ($/sf) for construction. This was applied to #{neat_numbers(affected_area_ip, 0)} (ft^2) across #{final_string.size} exterior wall constructions: #{final_string.sort.join(', ')}.")
|
416
|
-
|
417
|
-
return true
|
418
|
-
end
|
419
|
-
end
|
420
|
-
|
421
|
-
# this allows the measure to be used by the application
|
422
|
-
IncreaseInsulationRValueForExteriorWalls.new.registerWithApplication
|