openstudio-common-measures 0.3.0 → 0.3.1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/CHANGELOG.md +16 -0
- data/lib/openstudio/common_measures/version.rb +1 -1
- metadata +3 -63
- data/lib/measures/AddDaylightSensors/LICENSE.md +0 -27
- data/lib/measures/AddDaylightSensors/README.md +0 -136
- data/lib/measures/AddDaylightSensors/README.md.erb +0 -42
- data/lib/measures/AddDaylightSensors/measure.rb +0 -521
- data/lib/measures/AddDaylightSensors/measure.xml +0 -233
- data/lib/measures/EnableDemandControlledVentilation/LICENSE.md +0 -27
- data/lib/measures/EnableDemandControlledVentilation/README.md +0 -32
- data/lib/measures/EnableDemandControlledVentilation/README.md.erb +0 -42
- data/lib/measures/EnableDemandControlledVentilation/measure.rb +0 -154
- data/lib/measures/EnableDemandControlledVentilation/measure.xml +0 -99
- data/lib/measures/EnableEconomizerControl/LICENSE.md +0 -27
- data/lib/measures/EnableEconomizerControl/README.md +0 -48
- data/lib/measures/EnableEconomizerControl/README.md.erb +0 -42
- data/lib/measures/EnableEconomizerControl/measure.rb +0 -172
- data/lib/measures/EnableEconomizerControl/measure.xml +0 -124
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md +0 -64
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.rb +0 -422
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.xml +0 -150
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/README.md +0 -32
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/measure.rb +0 -328
- data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/measure.xml +0 -98
- data/lib/measures/IncreaseInsulationRValueForRoofs/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForRoofs/README.md +0 -64
- data/lib/measures/IncreaseInsulationRValueForRoofs/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForRoofs/measure.rb +0 -422
- data/lib/measures/IncreaseInsulationRValueForRoofs/measure.xml +0 -143
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/README.md +0 -32
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/measure.rb +0 -328
- data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/measure.xml +0 -98
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md +0 -97
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.rb +0 -450
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.xml +0 -186
- data/lib/measures/ReduceLightingLoadsByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceLightingLoadsByPercentage/README.md +0 -96
- data/lib/measures/ReduceLightingLoadsByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceLightingLoadsByPercentage/measure.rb +0 -513
- data/lib/measures/ReduceLightingLoadsByPercentage/measure.xml +0 -191
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md +0 -104
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.rb +0 -349
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.xml +0 -181
- data/lib/measures/ReduceVentilationByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceVentilationByPercentage/README.md +0 -40
- data/lib/measures/ReduceVentilationByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceVentilationByPercentage/measure.rb +0 -291
- data/lib/measures/ReduceVentilationByPercentage/measure.xml +0 -96
- data/lib/measures/create_variable_speed_rtu/LICENSE.md +0 -27
- data/lib/measures/create_variable_speed_rtu/README.md +0 -120
- data/lib/measures/create_variable_speed_rtu/README.md.erb +0 -42
- data/lib/measures/create_variable_speed_rtu/measure.rb +0 -539
- data/lib/measures/create_variable_speed_rtu/measure.xml +0 -207
@@ -1,233 +0,0 @@
|
|
1
|
-
<measure>
|
2
|
-
<schema_version>3.0</schema_version>
|
3
|
-
<name>add_daylight_sensors</name>
|
4
|
-
<uid>62babdc7-c81e-4dfd-96e8-af1628a55167</uid>
|
5
|
-
<version_id>5c889c90-31e5-40e9-835e-bb3230ad6fb8</version_id>
|
6
|
-
<version_modified>20200229T024319Z</version_modified>
|
7
|
-
<xml_checksum>0AC58119</xml_checksum>
|
8
|
-
<class_name>AddDaylightSensors</class_name>
|
9
|
-
<display_name>Add Daylight Sensor at the Center of Spaces with a Specified Space Type Assigned</display_name>
|
10
|
-
<description>This measure will add daylighting controls to spaces that that have space types assigned with names containing the string in the argument. You can also add a cost per space for sensors added to the model.</description>
|
11
|
-
<modeler_description>Make an array of the spaces that meet the criteria. Locate the sensor x and y values by averaging the min and max X and Y values from floor surfaces in the space. If a space already has a daylighting control, do not add a new one and leave the original in place. Warn the user if the space isn't assigned to a thermal zone, or if the space doesn't have any translucent surfaces. Note that the cost is added to the space not the sensor. If the sensor is removed at a later date, the cost will remain.</modeler_description>
|
12
|
-
<arguments>
|
13
|
-
<argument>
|
14
|
-
<name>space_type</name>
|
15
|
-
<display_name>Add Daylight Sensors to Spaces of This Space Type</display_name>
|
16
|
-
<type>Choice</type>
|
17
|
-
<required>true</required>
|
18
|
-
<model_dependent>false</model_dependent>
|
19
|
-
</argument>
|
20
|
-
<argument>
|
21
|
-
<name>setpoint</name>
|
22
|
-
<display_name>Daylighting Setpoint</display_name>
|
23
|
-
<type>Double</type>
|
24
|
-
<units>fc</units>
|
25
|
-
<required>true</required>
|
26
|
-
<model_dependent>false</model_dependent>
|
27
|
-
<default_value>45</default_value>
|
28
|
-
</argument>
|
29
|
-
<argument>
|
30
|
-
<name>control_type</name>
|
31
|
-
<display_name>Daylighting Control Type</display_name>
|
32
|
-
<type>Choice</type>
|
33
|
-
<required>true</required>
|
34
|
-
<model_dependent>false</model_dependent>
|
35
|
-
<default_value>Continuous/Off</default_value>
|
36
|
-
<choices>
|
37
|
-
<choice>
|
38
|
-
<value>None</value>
|
39
|
-
<display_name>None</display_name>
|
40
|
-
</choice>
|
41
|
-
<choice>
|
42
|
-
<value>Continuous</value>
|
43
|
-
<display_name>Continuous</display_name>
|
44
|
-
</choice>
|
45
|
-
<choice>
|
46
|
-
<value>Stepped</value>
|
47
|
-
<display_name>Stepped</display_name>
|
48
|
-
</choice>
|
49
|
-
<choice>
|
50
|
-
<value>Continuous/Off</value>
|
51
|
-
<display_name>Continuous/Off</display_name>
|
52
|
-
</choice>
|
53
|
-
</choices>
|
54
|
-
</argument>
|
55
|
-
<argument>
|
56
|
-
<name>min_power_fraction</name>
|
57
|
-
<display_name>Daylighting Minimum Input Power Fraction</display_name>
|
58
|
-
<description>min = 0 max = 0.6</description>
|
59
|
-
<type>Double</type>
|
60
|
-
<required>true</required>
|
61
|
-
<model_dependent>false</model_dependent>
|
62
|
-
<default_value>0.3</default_value>
|
63
|
-
</argument>
|
64
|
-
<argument>
|
65
|
-
<name>min_light_fraction</name>
|
66
|
-
<display_name>Daylighting Minimum Light Output Fraction</display_name>
|
67
|
-
<description>min = 0 max = 0.6</description>
|
68
|
-
<type>Double</type>
|
69
|
-
<required>true</required>
|
70
|
-
<model_dependent>false</model_dependent>
|
71
|
-
<default_value>0.2</default_value>
|
72
|
-
</argument>
|
73
|
-
<argument>
|
74
|
-
<name>fraction_zone_controlled</name>
|
75
|
-
<display_name>Fraction of zone controlled by daylight sensors</display_name>
|
76
|
-
<type>Double</type>
|
77
|
-
<required>true</required>
|
78
|
-
<model_dependent>false</model_dependent>
|
79
|
-
<default_value>1</default_value>
|
80
|
-
</argument>
|
81
|
-
<argument>
|
82
|
-
<name>height</name>
|
83
|
-
<display_name>Sensor Height</display_name>
|
84
|
-
<type>Double</type>
|
85
|
-
<units>inches</units>
|
86
|
-
<required>true</required>
|
87
|
-
<model_dependent>false</model_dependent>
|
88
|
-
<default_value>30</default_value>
|
89
|
-
</argument>
|
90
|
-
<argument>
|
91
|
-
<name>material_cost</name>
|
92
|
-
<display_name>Material and Installation Costs per Space for Daylight Sensor</display_name>
|
93
|
-
<type>Double</type>
|
94
|
-
<units>$</units>
|
95
|
-
<required>true</required>
|
96
|
-
<model_dependent>false</model_dependent>
|
97
|
-
<default_value>0</default_value>
|
98
|
-
</argument>
|
99
|
-
<argument>
|
100
|
-
<name>demolition_cost</name>
|
101
|
-
<display_name>Demolition Costs per Space for Daylight Sensor</display_name>
|
102
|
-
<type>Double</type>
|
103
|
-
<units>$</units>
|
104
|
-
<required>true</required>
|
105
|
-
<model_dependent>false</model_dependent>
|
106
|
-
<default_value>0</default_value>
|
107
|
-
</argument>
|
108
|
-
<argument>
|
109
|
-
<name>years_until_costs_start</name>
|
110
|
-
<display_name>Years Until Costs Start</display_name>
|
111
|
-
<type>Integer</type>
|
112
|
-
<units>whole years</units>
|
113
|
-
<required>true</required>
|
114
|
-
<model_dependent>false</model_dependent>
|
115
|
-
<default_value>0</default_value>
|
116
|
-
</argument>
|
117
|
-
<argument>
|
118
|
-
<name>demo_cost_initial_const</name>
|
119
|
-
<display_name>Demolition Costs Occur During Initial Construction</display_name>
|
120
|
-
<type>Boolean</type>
|
121
|
-
<required>true</required>
|
122
|
-
<model_dependent>false</model_dependent>
|
123
|
-
<default_value>false</default_value>
|
124
|
-
<choices>
|
125
|
-
<choice>
|
126
|
-
<value>true</value>
|
127
|
-
<display_name>true</display_name>
|
128
|
-
</choice>
|
129
|
-
<choice>
|
130
|
-
<value>false</value>
|
131
|
-
<display_name>false</display_name>
|
132
|
-
</choice>
|
133
|
-
</choices>
|
134
|
-
</argument>
|
135
|
-
<argument>
|
136
|
-
<name>expected_life</name>
|
137
|
-
<display_name>Expected Life</display_name>
|
138
|
-
<type>Integer</type>
|
139
|
-
<units>whole years</units>
|
140
|
-
<required>true</required>
|
141
|
-
<model_dependent>false</model_dependent>
|
142
|
-
<default_value>20</default_value>
|
143
|
-
</argument>
|
144
|
-
<argument>
|
145
|
-
<name>om_cost</name>
|
146
|
-
<display_name>O & M Costs per Space for Daylight Sensor</display_name>
|
147
|
-
<type>Double</type>
|
148
|
-
<units>$</units>
|
149
|
-
<required>true</required>
|
150
|
-
<model_dependent>false</model_dependent>
|
151
|
-
<default_value>0</default_value>
|
152
|
-
</argument>
|
153
|
-
<argument>
|
154
|
-
<name>om_frequency</name>
|
155
|
-
<display_name>O & M Frequency</display_name>
|
156
|
-
<type>Integer</type>
|
157
|
-
<units>whole years</units>
|
158
|
-
<required>true</required>
|
159
|
-
<model_dependent>false</model_dependent>
|
160
|
-
<default_value>1</default_value>
|
161
|
-
</argument>
|
162
|
-
</arguments>
|
163
|
-
<outputs/>
|
164
|
-
<provenances/>
|
165
|
-
<tags>
|
166
|
-
<tag>Electric Lighting.Electric Lighting Controls</tag>
|
167
|
-
</tags>
|
168
|
-
<attributes>
|
169
|
-
<attribute>
|
170
|
-
<name>Measure Type</name>
|
171
|
-
<value>ModelMeasure</value>
|
172
|
-
<datatype>string</datatype>
|
173
|
-
</attribute>
|
174
|
-
<attribute>
|
175
|
-
<name>Measure Function</name>
|
176
|
-
<value>Measure</value>
|
177
|
-
<datatype>string</datatype>
|
178
|
-
</attribute>
|
179
|
-
<attribute>
|
180
|
-
<name>Requires EnergyPlus Results</name>
|
181
|
-
<value>false</value>
|
182
|
-
<datatype>boolean</datatype>
|
183
|
-
</attribute>
|
184
|
-
<attribute>
|
185
|
-
<name>Uses SketchUp API</name>
|
186
|
-
<value>false</value>
|
187
|
-
<datatype>boolean</datatype>
|
188
|
-
</attribute>
|
189
|
-
</attributes>
|
190
|
-
<files>
|
191
|
-
<file>
|
192
|
-
<filename>ModelForDaylightSensors.osm</filename>
|
193
|
-
<filetype>osm</filetype>
|
194
|
-
<usage_type>test</usage_type>
|
195
|
-
<checksum>34D67AAA</checksum>
|
196
|
-
</file>
|
197
|
-
<file>
|
198
|
-
<filename>README.md.erb</filename>
|
199
|
-
<filetype>erb</filetype>
|
200
|
-
<usage_type>readmeerb</usage_type>
|
201
|
-
<checksum>703C9964</checksum>
|
202
|
-
</file>
|
203
|
-
<file>
|
204
|
-
<filename>README.md</filename>
|
205
|
-
<filetype>md</filetype>
|
206
|
-
<usage_type>readme</usage_type>
|
207
|
-
<checksum>F3117543</checksum>
|
208
|
-
</file>
|
209
|
-
<file>
|
210
|
-
<filename>LICENSE.md</filename>
|
211
|
-
<filetype>md</filetype>
|
212
|
-
<usage_type>license</usage_type>
|
213
|
-
<checksum>E0468DD6</checksum>
|
214
|
-
</file>
|
215
|
-
<file>
|
216
|
-
<version>
|
217
|
-
<software_program>OpenStudio</software_program>
|
218
|
-
<identifier>2.0.0</identifier>
|
219
|
-
<min_compatible>2.0.0</min_compatible>
|
220
|
-
</version>
|
221
|
-
<filename>measure.rb</filename>
|
222
|
-
<filetype>rb</filetype>
|
223
|
-
<usage_type>script</usage_type>
|
224
|
-
<checksum>46FDF582</checksum>
|
225
|
-
</file>
|
226
|
-
<file>
|
227
|
-
<filename>AddDaylightSensors_Test.rb</filename>
|
228
|
-
<filetype>rb</filetype>
|
229
|
-
<usage_type>test</usage_type>
|
230
|
-
<checksum>5C6D0627</checksum>
|
231
|
-
</file>
|
232
|
-
</files>
|
233
|
-
</measure>
|
@@ -1,27 +0,0 @@
|
|
1
|
-
OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC. All rights reserved.
|
2
|
-
|
3
|
-
Redistribution and use in source and binary forms, with or without modification, are permitted
|
4
|
-
provided that the following conditions are met:
|
5
|
-
|
6
|
-
(1) Redistributions of source code must retain the above copyright notice, this list of conditions
|
7
|
-
and the following disclaimer.
|
8
|
-
|
9
|
-
(2) Redistributions in binary form must reproduce the above copyright notice, this list of conditions
|
10
|
-
and the following disclaimer in the documentation and/or other materials provided with the distribution.
|
11
|
-
|
12
|
-
(3) Neither the name of the copyright holder nor the names of any contributors may be used to endorse
|
13
|
-
or promote products derived from this software without specific prior written permission from the
|
14
|
-
respective party.
|
15
|
-
|
16
|
-
(4) Other than as required in clauses (1) and (2), distributions in any form of modifications or other
|
17
|
-
derivative works may not use the "OpenStudio" trademark, "OS", "os", or any other confusingly similar
|
18
|
-
designation without specific prior written permission from Alliance for Sustainable Energy, LLC.
|
19
|
-
|
20
|
-
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED
|
21
|
-
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
|
22
|
-
PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER, THE UNITED STATES GOVERNMENT,
|
23
|
-
OR ANY CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
24
|
-
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,
|
25
|
-
OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
|
26
|
-
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
|
27
|
-
SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
@@ -1,32 +0,0 @@
|
|
1
|
-
|
2
|
-
|
3
|
-
###### (Automatically generated documentation)
|
4
|
-
|
5
|
-
# Enable Demand Controlled Ventilation
|
6
|
-
|
7
|
-
## Description
|
8
|
-
|
9
|
-
|
10
|
-
## Modeler Description
|
11
|
-
|
12
|
-
|
13
|
-
## Measure Type
|
14
|
-
ModelMeasure
|
15
|
-
|
16
|
-
## Taxonomy
|
17
|
-
|
18
|
-
|
19
|
-
## Arguments
|
20
|
-
|
21
|
-
|
22
|
-
### DCV Type
|
23
|
-
|
24
|
-
**Name:** dcv_type,
|
25
|
-
**Type:** Choice,
|
26
|
-
**Units:** ,
|
27
|
-
**Required:** true,
|
28
|
-
**Model Dependent:** false
|
29
|
-
|
30
|
-
|
31
|
-
|
32
|
-
|
@@ -1,42 +0,0 @@
|
|
1
|
-
<%#= README.md.erb is used to auto-generate README.md. %>
|
2
|
-
<%#= To manually maintain README.md throw away README.md.erb and manually edit README.md %>
|
3
|
-
###### (Automatically generated documentation)
|
4
|
-
|
5
|
-
# <%= name %>
|
6
|
-
|
7
|
-
## Description
|
8
|
-
<%= description %>
|
9
|
-
|
10
|
-
## Modeler Description
|
11
|
-
<%= modelerDescription %>
|
12
|
-
|
13
|
-
## Measure Type
|
14
|
-
<%= measureType %>
|
15
|
-
|
16
|
-
## Taxonomy
|
17
|
-
<%= taxonomy %>
|
18
|
-
|
19
|
-
## Arguments
|
20
|
-
|
21
|
-
<% arguments.each do |argument| %>
|
22
|
-
### <%= argument[:display_name] %>
|
23
|
-
<%= argument[:description] %>
|
24
|
-
**Name:** <%= argument[:name] %>,
|
25
|
-
**Type:** <%= argument[:type] %>,
|
26
|
-
**Units:** <%= argument[:units] %>,
|
27
|
-
**Required:** <%= argument[:required] %>,
|
28
|
-
**Model Dependent:** <%= argument[:model_dependent] %>
|
29
|
-
<% end %>
|
30
|
-
|
31
|
-
<% if arguments.size == 0 %>
|
32
|
-
<%= "This measure does not have any user arguments" %>
|
33
|
-
<% end %>
|
34
|
-
|
35
|
-
<% if outputs.size > 0 %>
|
36
|
-
## Outputs
|
37
|
-
<% output_names = [] %>
|
38
|
-
<% outputs.each do |output| %>
|
39
|
-
<% output_names << output[:display_name] %>
|
40
|
-
<% end %>
|
41
|
-
<%= output_names.join(", ") %>
|
42
|
-
<% end %>
|
@@ -1,154 +0,0 @@
|
|
1
|
-
# *******************************************************************************
|
2
|
-
# OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC.
|
3
|
-
# All rights reserved.
|
4
|
-
# Redistribution and use in source and binary forms, with or without
|
5
|
-
# modification, are permitted provided that the following conditions are met:
|
6
|
-
#
|
7
|
-
# (1) Redistributions of source code must retain the above copyright notice,
|
8
|
-
# this list of conditions and the following disclaimer.
|
9
|
-
#
|
10
|
-
# (2) Redistributions in binary form must reproduce the above copyright notice,
|
11
|
-
# this list of conditions and the following disclaimer in the documentation
|
12
|
-
# and/or other materials provided with the distribution.
|
13
|
-
#
|
14
|
-
# (3) Neither the name of the copyright holder nor the names of any contributors
|
15
|
-
# may be used to endorse or promote products derived from this software without
|
16
|
-
# specific prior written permission from the respective party.
|
17
|
-
#
|
18
|
-
# (4) Other than as required in clauses (1) and (2), distributions in any form
|
19
|
-
# of modifications or other derivative works may not use the "OpenStudio"
|
20
|
-
# trademark, "OS", "os", or any other confusingly similar designation without
|
21
|
-
# specific prior written permission from Alliance for Sustainable Energy, LLC.
|
22
|
-
#
|
23
|
-
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS
|
24
|
-
# "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
|
25
|
-
# THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
26
|
-
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE
|
27
|
-
# UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF
|
28
|
-
# THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
|
29
|
-
# EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT
|
30
|
-
# OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
|
31
|
-
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
|
32
|
-
# STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
33
|
-
# OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
34
|
-
# *******************************************************************************
|
35
|
-
|
36
|
-
# see the URL below for information on how to write OpenStudio measures
|
37
|
-
# http://openstudio.nrel.gov/openstudio-measure-writing-guide
|
38
|
-
|
39
|
-
# see the URL below for information on using life cycle cost objects in OpenStudio
|
40
|
-
# http://openstudio.nrel.gov/openstudio-life-cycle-examples
|
41
|
-
|
42
|
-
# see the URL below for access to C++ documentation on model objects (click on "model" in the main window to view model objects)
|
43
|
-
# http://openstudio.nrel.gov/sites/openstudio.nrel.gov/files/nv_data/cpp_documentation_it/model/html/namespaces.html
|
44
|
-
|
45
|
-
# start the measure
|
46
|
-
class EnableDemandControlledVentilation < OpenStudio::Measure::ModelMeasure
|
47
|
-
# define the name that a user will see, this method may be deprecated as
|
48
|
-
# the display name in PAT comes from the name field in measure.xml
|
49
|
-
def name
|
50
|
-
return 'Enable Demand Controlled Ventilation'
|
51
|
-
end
|
52
|
-
|
53
|
-
# define the arguments that the user will input
|
54
|
-
def arguments(model)
|
55
|
-
args = OpenStudio::Measure::OSArgumentVector.new
|
56
|
-
|
57
|
-
# make choice argument economizer control type
|
58
|
-
choices = OpenStudio::StringVector.new
|
59
|
-
choices << 'EnableDCV'
|
60
|
-
choices << 'DisableDCV'
|
61
|
-
choices << 'NoChange'
|
62
|
-
dcv_type = OpenStudio::Measure::OSArgument.makeChoiceArgument('dcv_type', choices, true)
|
63
|
-
dcv_type.setDisplayName('DCV Type')
|
64
|
-
args << dcv_type
|
65
|
-
|
66
|
-
return args
|
67
|
-
end
|
68
|
-
|
69
|
-
# define what happens when the measure is cop
|
70
|
-
def run(model, runner, user_arguments)
|
71
|
-
super(model, runner, user_arguments)
|
72
|
-
|
73
|
-
# use the built-in error checking
|
74
|
-
if !runner.validateUserArguments(arguments(model), user_arguments)
|
75
|
-
return false
|
76
|
-
end
|
77
|
-
|
78
|
-
# assign the user inputs to variables
|
79
|
-
dcv_type = runner.getStringArgumentValue('dcv_type', user_arguments)
|
80
|
-
|
81
|
-
# Note if dcv_type == NoChange
|
82
|
-
# and register as N/A
|
83
|
-
if dcv_type == 'NoChange'
|
84
|
-
runner.registerAsNotApplicable('N/A - User requested No Change in economizer operation.')
|
85
|
-
return true
|
86
|
-
end
|
87
|
-
|
88
|
-
# short def to make numbers pretty (converts 4125001.25641 to 4,125,001.26 or 4,125,001). The definition be called through this measure
|
89
|
-
def neat_numbers(number, roundto = 2) # round to 0 or 2)
|
90
|
-
if roundto == 2
|
91
|
-
number = format '%.2f', number
|
92
|
-
else
|
93
|
-
number = number.round
|
94
|
-
end
|
95
|
-
# regex to add commas
|
96
|
-
number.to_s.reverse.gsub(/([0-9]{3}(?=([0-9])))/, '\\1,').reverse
|
97
|
-
end
|
98
|
-
|
99
|
-
# info for initial condition
|
100
|
-
air_loops_changed = []
|
101
|
-
|
102
|
-
# loop through air loops
|
103
|
-
model.getAirLoopHVACs.each do |air_loop|
|
104
|
-
# find AirLoopHVACOutdoorAirSystem on loop
|
105
|
-
air_loop.supplyComponents.each do |supply_component|
|
106
|
-
hVACComponent = supply_component.to_AirLoopHVACOutdoorAirSystem
|
107
|
-
if !hVACComponent.empty?
|
108
|
-
hVACComponent = hVACComponent.get
|
109
|
-
|
110
|
-
# get ControllerOutdoorAir
|
111
|
-
controller_oa = hVACComponent.getControllerOutdoorAir
|
112
|
-
|
113
|
-
# get ControllerMechanicalVentilation
|
114
|
-
controller_mv = controller_oa.controllerMechanicalVentilation
|
115
|
-
|
116
|
-
if dcv_type == 'EnableDCV'
|
117
|
-
# check if demand control is enabled, if not, then enable it
|
118
|
-
if controller_mv.demandControlledVentilation == true
|
119
|
-
runner.registerInfo("#{air_loop.name} already has DCV enabled.")
|
120
|
-
else
|
121
|
-
controller_mv.setDemandControlledVentilation(true)
|
122
|
-
runner.registerInfo("Enabling DCV for #{air_loop.name}.")
|
123
|
-
air_loops_changed << air_loop
|
124
|
-
end
|
125
|
-
elsif dcv_type == 'DisableDCV'
|
126
|
-
# check if demand control is disabled, if not, then disabled it
|
127
|
-
if controller_mv.demandControlledVentilation == false
|
128
|
-
runner.registerInfo("#{air_loop.name} already has DCV disabled.")
|
129
|
-
else
|
130
|
-
controller_mv.setDemandControlledVentilation(false)
|
131
|
-
runner.registerInfo("Disabling DCV for #{air_loop.name}.")
|
132
|
-
air_loops_changed << air_loop
|
133
|
-
end
|
134
|
-
end
|
135
|
-
|
136
|
-
end
|
137
|
-
end
|
138
|
-
end
|
139
|
-
|
140
|
-
# Report N/A if none of the air loops were changed
|
141
|
-
if air_loops_changed.empty?
|
142
|
-
runner.registerAsNotApplicable('No air loops had DCV enabled or disabled.')
|
143
|
-
return true
|
144
|
-
end
|
145
|
-
|
146
|
-
# Report final condition of model
|
147
|
-
runner.registerFinalCondition("#{air_loops_changed.size} air loops now have demand controlled ventilation enabled.")
|
148
|
-
|
149
|
-
return true
|
150
|
-
end
|
151
|
-
end
|
152
|
-
|
153
|
-
# this allows the measure to be use by the application
|
154
|
-
EnableDemandControlledVentilation.new.registerWithApplication
|