openstudio-common-measures 0.3.0 → 0.3.1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (64) hide show
  1. checksums.yaml +4 -4
  2. data/CHANGELOG.md +16 -0
  3. data/lib/openstudio/common_measures/version.rb +1 -1
  4. metadata +3 -63
  5. data/lib/measures/AddDaylightSensors/LICENSE.md +0 -27
  6. data/lib/measures/AddDaylightSensors/README.md +0 -136
  7. data/lib/measures/AddDaylightSensors/README.md.erb +0 -42
  8. data/lib/measures/AddDaylightSensors/measure.rb +0 -521
  9. data/lib/measures/AddDaylightSensors/measure.xml +0 -233
  10. data/lib/measures/EnableDemandControlledVentilation/LICENSE.md +0 -27
  11. data/lib/measures/EnableDemandControlledVentilation/README.md +0 -32
  12. data/lib/measures/EnableDemandControlledVentilation/README.md.erb +0 -42
  13. data/lib/measures/EnableDemandControlledVentilation/measure.rb +0 -154
  14. data/lib/measures/EnableDemandControlledVentilation/measure.xml +0 -99
  15. data/lib/measures/EnableEconomizerControl/LICENSE.md +0 -27
  16. data/lib/measures/EnableEconomizerControl/README.md +0 -48
  17. data/lib/measures/EnableEconomizerControl/README.md.erb +0 -42
  18. data/lib/measures/EnableEconomizerControl/measure.rb +0 -172
  19. data/lib/measures/EnableEconomizerControl/measure.xml +0 -124
  20. data/lib/measures/IncreaseInsulationRValueForExteriorWalls/LICENSE.md +0 -27
  21. data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md +0 -64
  22. data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md.erb +0 -42
  23. data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.rb +0 -422
  24. data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.xml +0 -150
  25. data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/LICENSE.md +0 -27
  26. data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/README.md +0 -32
  27. data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/README.md.erb +0 -42
  28. data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/measure.rb +0 -328
  29. data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/measure.xml +0 -98
  30. data/lib/measures/IncreaseInsulationRValueForRoofs/LICENSE.md +0 -27
  31. data/lib/measures/IncreaseInsulationRValueForRoofs/README.md +0 -64
  32. data/lib/measures/IncreaseInsulationRValueForRoofs/README.md.erb +0 -42
  33. data/lib/measures/IncreaseInsulationRValueForRoofs/measure.rb +0 -422
  34. data/lib/measures/IncreaseInsulationRValueForRoofs/measure.xml +0 -143
  35. data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/LICENSE.md +0 -27
  36. data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/README.md +0 -32
  37. data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/README.md.erb +0 -42
  38. data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/measure.rb +0 -328
  39. data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/measure.xml +0 -98
  40. data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/LICENSE.md +0 -27
  41. data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md +0 -97
  42. data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md.erb +0 -42
  43. data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.rb +0 -450
  44. data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.xml +0 -186
  45. data/lib/measures/ReduceLightingLoadsByPercentage/LICENSE.md +0 -27
  46. data/lib/measures/ReduceLightingLoadsByPercentage/README.md +0 -96
  47. data/lib/measures/ReduceLightingLoadsByPercentage/README.md.erb +0 -42
  48. data/lib/measures/ReduceLightingLoadsByPercentage/measure.rb +0 -513
  49. data/lib/measures/ReduceLightingLoadsByPercentage/measure.xml +0 -191
  50. data/lib/measures/ReduceSpaceInfiltrationByPercentage/LICENSE.md +0 -27
  51. data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md +0 -104
  52. data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md.erb +0 -42
  53. data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.rb +0 -349
  54. data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.xml +0 -181
  55. data/lib/measures/ReduceVentilationByPercentage/LICENSE.md +0 -27
  56. data/lib/measures/ReduceVentilationByPercentage/README.md +0 -40
  57. data/lib/measures/ReduceVentilationByPercentage/README.md.erb +0 -42
  58. data/lib/measures/ReduceVentilationByPercentage/measure.rb +0 -291
  59. data/lib/measures/ReduceVentilationByPercentage/measure.xml +0 -96
  60. data/lib/measures/create_variable_speed_rtu/LICENSE.md +0 -27
  61. data/lib/measures/create_variable_speed_rtu/README.md +0 -120
  62. data/lib/measures/create_variable_speed_rtu/README.md.erb +0 -42
  63. data/lib/measures/create_variable_speed_rtu/measure.rb +0 -539
  64. data/lib/measures/create_variable_speed_rtu/measure.xml +0 -207
@@ -1,233 +0,0 @@
1
- <measure>
2
- <schema_version>3.0</schema_version>
3
- <name>add_daylight_sensors</name>
4
- <uid>62babdc7-c81e-4dfd-96e8-af1628a55167</uid>
5
- <version_id>5c889c90-31e5-40e9-835e-bb3230ad6fb8</version_id>
6
- <version_modified>20200229T024319Z</version_modified>
7
- <xml_checksum>0AC58119</xml_checksum>
8
- <class_name>AddDaylightSensors</class_name>
9
- <display_name>Add Daylight Sensor at the Center of Spaces with a Specified Space Type Assigned</display_name>
10
- <description>This measure will add daylighting controls to spaces that that have space types assigned with names containing the string in the argument. You can also add a cost per space for sensors added to the model.</description>
11
- <modeler_description>Make an array of the spaces that meet the criteria. Locate the sensor x and y values by averaging the min and max X and Y values from floor surfaces in the space. If a space already has a daylighting control, do not add a new one and leave the original in place. Warn the user if the space isn't assigned to a thermal zone, or if the space doesn't have any translucent surfaces. Note that the cost is added to the space not the sensor. If the sensor is removed at a later date, the cost will remain.</modeler_description>
12
- <arguments>
13
- <argument>
14
- <name>space_type</name>
15
- <display_name>Add Daylight Sensors to Spaces of This Space Type</display_name>
16
- <type>Choice</type>
17
- <required>true</required>
18
- <model_dependent>false</model_dependent>
19
- </argument>
20
- <argument>
21
- <name>setpoint</name>
22
- <display_name>Daylighting Setpoint</display_name>
23
- <type>Double</type>
24
- <units>fc</units>
25
- <required>true</required>
26
- <model_dependent>false</model_dependent>
27
- <default_value>45</default_value>
28
- </argument>
29
- <argument>
30
- <name>control_type</name>
31
- <display_name>Daylighting Control Type</display_name>
32
- <type>Choice</type>
33
- <required>true</required>
34
- <model_dependent>false</model_dependent>
35
- <default_value>Continuous/Off</default_value>
36
- <choices>
37
- <choice>
38
- <value>None</value>
39
- <display_name>None</display_name>
40
- </choice>
41
- <choice>
42
- <value>Continuous</value>
43
- <display_name>Continuous</display_name>
44
- </choice>
45
- <choice>
46
- <value>Stepped</value>
47
- <display_name>Stepped</display_name>
48
- </choice>
49
- <choice>
50
- <value>Continuous/Off</value>
51
- <display_name>Continuous/Off</display_name>
52
- </choice>
53
- </choices>
54
- </argument>
55
- <argument>
56
- <name>min_power_fraction</name>
57
- <display_name>Daylighting Minimum Input Power Fraction</display_name>
58
- <description>min = 0 max = 0.6</description>
59
- <type>Double</type>
60
- <required>true</required>
61
- <model_dependent>false</model_dependent>
62
- <default_value>0.3</default_value>
63
- </argument>
64
- <argument>
65
- <name>min_light_fraction</name>
66
- <display_name>Daylighting Minimum Light Output Fraction</display_name>
67
- <description>min = 0 max = 0.6</description>
68
- <type>Double</type>
69
- <required>true</required>
70
- <model_dependent>false</model_dependent>
71
- <default_value>0.2</default_value>
72
- </argument>
73
- <argument>
74
- <name>fraction_zone_controlled</name>
75
- <display_name>Fraction of zone controlled by daylight sensors</display_name>
76
- <type>Double</type>
77
- <required>true</required>
78
- <model_dependent>false</model_dependent>
79
- <default_value>1</default_value>
80
- </argument>
81
- <argument>
82
- <name>height</name>
83
- <display_name>Sensor Height</display_name>
84
- <type>Double</type>
85
- <units>inches</units>
86
- <required>true</required>
87
- <model_dependent>false</model_dependent>
88
- <default_value>30</default_value>
89
- </argument>
90
- <argument>
91
- <name>material_cost</name>
92
- <display_name>Material and Installation Costs per Space for Daylight Sensor</display_name>
93
- <type>Double</type>
94
- <units>$</units>
95
- <required>true</required>
96
- <model_dependent>false</model_dependent>
97
- <default_value>0</default_value>
98
- </argument>
99
- <argument>
100
- <name>demolition_cost</name>
101
- <display_name>Demolition Costs per Space for Daylight Sensor</display_name>
102
- <type>Double</type>
103
- <units>$</units>
104
- <required>true</required>
105
- <model_dependent>false</model_dependent>
106
- <default_value>0</default_value>
107
- </argument>
108
- <argument>
109
- <name>years_until_costs_start</name>
110
- <display_name>Years Until Costs Start</display_name>
111
- <type>Integer</type>
112
- <units>whole years</units>
113
- <required>true</required>
114
- <model_dependent>false</model_dependent>
115
- <default_value>0</default_value>
116
- </argument>
117
- <argument>
118
- <name>demo_cost_initial_const</name>
119
- <display_name>Demolition Costs Occur During Initial Construction</display_name>
120
- <type>Boolean</type>
121
- <required>true</required>
122
- <model_dependent>false</model_dependent>
123
- <default_value>false</default_value>
124
- <choices>
125
- <choice>
126
- <value>true</value>
127
- <display_name>true</display_name>
128
- </choice>
129
- <choice>
130
- <value>false</value>
131
- <display_name>false</display_name>
132
- </choice>
133
- </choices>
134
- </argument>
135
- <argument>
136
- <name>expected_life</name>
137
- <display_name>Expected Life</display_name>
138
- <type>Integer</type>
139
- <units>whole years</units>
140
- <required>true</required>
141
- <model_dependent>false</model_dependent>
142
- <default_value>20</default_value>
143
- </argument>
144
- <argument>
145
- <name>om_cost</name>
146
- <display_name>O &amp; M Costs per Space for Daylight Sensor</display_name>
147
- <type>Double</type>
148
- <units>$</units>
149
- <required>true</required>
150
- <model_dependent>false</model_dependent>
151
- <default_value>0</default_value>
152
- </argument>
153
- <argument>
154
- <name>om_frequency</name>
155
- <display_name>O &amp; M Frequency</display_name>
156
- <type>Integer</type>
157
- <units>whole years</units>
158
- <required>true</required>
159
- <model_dependent>false</model_dependent>
160
- <default_value>1</default_value>
161
- </argument>
162
- </arguments>
163
- <outputs/>
164
- <provenances/>
165
- <tags>
166
- <tag>Electric Lighting.Electric Lighting Controls</tag>
167
- </tags>
168
- <attributes>
169
- <attribute>
170
- <name>Measure Type</name>
171
- <value>ModelMeasure</value>
172
- <datatype>string</datatype>
173
- </attribute>
174
- <attribute>
175
- <name>Measure Function</name>
176
- <value>Measure</value>
177
- <datatype>string</datatype>
178
- </attribute>
179
- <attribute>
180
- <name>Requires EnergyPlus Results</name>
181
- <value>false</value>
182
- <datatype>boolean</datatype>
183
- </attribute>
184
- <attribute>
185
- <name>Uses SketchUp API</name>
186
- <value>false</value>
187
- <datatype>boolean</datatype>
188
- </attribute>
189
- </attributes>
190
- <files>
191
- <file>
192
- <filename>ModelForDaylightSensors.osm</filename>
193
- <filetype>osm</filetype>
194
- <usage_type>test</usage_type>
195
- <checksum>34D67AAA</checksum>
196
- </file>
197
- <file>
198
- <filename>README.md.erb</filename>
199
- <filetype>erb</filetype>
200
- <usage_type>readmeerb</usage_type>
201
- <checksum>703C9964</checksum>
202
- </file>
203
- <file>
204
- <filename>README.md</filename>
205
- <filetype>md</filetype>
206
- <usage_type>readme</usage_type>
207
- <checksum>F3117543</checksum>
208
- </file>
209
- <file>
210
- <filename>LICENSE.md</filename>
211
- <filetype>md</filetype>
212
- <usage_type>license</usage_type>
213
- <checksum>E0468DD6</checksum>
214
- </file>
215
- <file>
216
- <version>
217
- <software_program>OpenStudio</software_program>
218
- <identifier>2.0.0</identifier>
219
- <min_compatible>2.0.0</min_compatible>
220
- </version>
221
- <filename>measure.rb</filename>
222
- <filetype>rb</filetype>
223
- <usage_type>script</usage_type>
224
- <checksum>46FDF582</checksum>
225
- </file>
226
- <file>
227
- <filename>AddDaylightSensors_Test.rb</filename>
228
- <filetype>rb</filetype>
229
- <usage_type>test</usage_type>
230
- <checksum>5C6D0627</checksum>
231
- </file>
232
- </files>
233
- </measure>
@@ -1,27 +0,0 @@
1
- OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC. All rights reserved.
2
-
3
- Redistribution and use in source and binary forms, with or without modification, are permitted
4
- provided that the following conditions are met:
5
-
6
- (1) Redistributions of source code must retain the above copyright notice, this list of conditions
7
- and the following disclaimer.
8
-
9
- (2) Redistributions in binary form must reproduce the above copyright notice, this list of conditions
10
- and the following disclaimer in the documentation and/or other materials provided with the distribution.
11
-
12
- (3) Neither the name of the copyright holder nor the names of any contributors may be used to endorse
13
- or promote products derived from this software without specific prior written permission from the
14
- respective party.
15
-
16
- (4) Other than as required in clauses (1) and (2), distributions in any form of modifications or other
17
- derivative works may not use the "OpenStudio" trademark, "OS", "os", or any other confusingly similar
18
- designation without specific prior written permission from Alliance for Sustainable Energy, LLC.
19
-
20
- THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED
21
- WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
22
- PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER, THE UNITED STATES GOVERNMENT,
23
- OR ANY CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
24
- DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,
25
- OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
26
- STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
27
- SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
@@ -1,32 +0,0 @@
1
-
2
-
3
- ###### (Automatically generated documentation)
4
-
5
- # Enable Demand Controlled Ventilation
6
-
7
- ## Description
8
-
9
-
10
- ## Modeler Description
11
-
12
-
13
- ## Measure Type
14
- ModelMeasure
15
-
16
- ## Taxonomy
17
-
18
-
19
- ## Arguments
20
-
21
-
22
- ### DCV Type
23
-
24
- **Name:** dcv_type,
25
- **Type:** Choice,
26
- **Units:** ,
27
- **Required:** true,
28
- **Model Dependent:** false
29
-
30
-
31
-
32
-
@@ -1,42 +0,0 @@
1
- <%#= README.md.erb is used to auto-generate README.md. %>
2
- <%#= To manually maintain README.md throw away README.md.erb and manually edit README.md %>
3
- ###### (Automatically generated documentation)
4
-
5
- # <%= name %>
6
-
7
- ## Description
8
- <%= description %>
9
-
10
- ## Modeler Description
11
- <%= modelerDescription %>
12
-
13
- ## Measure Type
14
- <%= measureType %>
15
-
16
- ## Taxonomy
17
- <%= taxonomy %>
18
-
19
- ## Arguments
20
-
21
- <% arguments.each do |argument| %>
22
- ### <%= argument[:display_name] %>
23
- <%= argument[:description] %>
24
- **Name:** <%= argument[:name] %>,
25
- **Type:** <%= argument[:type] %>,
26
- **Units:** <%= argument[:units] %>,
27
- **Required:** <%= argument[:required] %>,
28
- **Model Dependent:** <%= argument[:model_dependent] %>
29
- <% end %>
30
-
31
- <% if arguments.size == 0 %>
32
- <%= "This measure does not have any user arguments" %>
33
- <% end %>
34
-
35
- <% if outputs.size > 0 %>
36
- ## Outputs
37
- <% output_names = [] %>
38
- <% outputs.each do |output| %>
39
- <% output_names << output[:display_name] %>
40
- <% end %>
41
- <%= output_names.join(", ") %>
42
- <% end %>
@@ -1,154 +0,0 @@
1
- # *******************************************************************************
2
- # OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC.
3
- # All rights reserved.
4
- # Redistribution and use in source and binary forms, with or without
5
- # modification, are permitted provided that the following conditions are met:
6
- #
7
- # (1) Redistributions of source code must retain the above copyright notice,
8
- # this list of conditions and the following disclaimer.
9
- #
10
- # (2) Redistributions in binary form must reproduce the above copyright notice,
11
- # this list of conditions and the following disclaimer in the documentation
12
- # and/or other materials provided with the distribution.
13
- #
14
- # (3) Neither the name of the copyright holder nor the names of any contributors
15
- # may be used to endorse or promote products derived from this software without
16
- # specific prior written permission from the respective party.
17
- #
18
- # (4) Other than as required in clauses (1) and (2), distributions in any form
19
- # of modifications or other derivative works may not use the "OpenStudio"
20
- # trademark, "OS", "os", or any other confusingly similar designation without
21
- # specific prior written permission from Alliance for Sustainable Energy, LLC.
22
- #
23
- # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS
24
- # "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
25
- # THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
26
- # ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE
27
- # UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF
28
- # THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
29
- # EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT
30
- # OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
31
- # INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
32
- # STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
33
- # OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
34
- # *******************************************************************************
35
-
36
- # see the URL below for information on how to write OpenStudio measures
37
- # http://openstudio.nrel.gov/openstudio-measure-writing-guide
38
-
39
- # see the URL below for information on using life cycle cost objects in OpenStudio
40
- # http://openstudio.nrel.gov/openstudio-life-cycle-examples
41
-
42
- # see the URL below for access to C++ documentation on model objects (click on "model" in the main window to view model objects)
43
- # http://openstudio.nrel.gov/sites/openstudio.nrel.gov/files/nv_data/cpp_documentation_it/model/html/namespaces.html
44
-
45
- # start the measure
46
- class EnableDemandControlledVentilation < OpenStudio::Measure::ModelMeasure
47
- # define the name that a user will see, this method may be deprecated as
48
- # the display name in PAT comes from the name field in measure.xml
49
- def name
50
- return 'Enable Demand Controlled Ventilation'
51
- end
52
-
53
- # define the arguments that the user will input
54
- def arguments(model)
55
- args = OpenStudio::Measure::OSArgumentVector.new
56
-
57
- # make choice argument economizer control type
58
- choices = OpenStudio::StringVector.new
59
- choices << 'EnableDCV'
60
- choices << 'DisableDCV'
61
- choices << 'NoChange'
62
- dcv_type = OpenStudio::Measure::OSArgument.makeChoiceArgument('dcv_type', choices, true)
63
- dcv_type.setDisplayName('DCV Type')
64
- args << dcv_type
65
-
66
- return args
67
- end
68
-
69
- # define what happens when the measure is cop
70
- def run(model, runner, user_arguments)
71
- super(model, runner, user_arguments)
72
-
73
- # use the built-in error checking
74
- if !runner.validateUserArguments(arguments(model), user_arguments)
75
- return false
76
- end
77
-
78
- # assign the user inputs to variables
79
- dcv_type = runner.getStringArgumentValue('dcv_type', user_arguments)
80
-
81
- # Note if dcv_type == NoChange
82
- # and register as N/A
83
- if dcv_type == 'NoChange'
84
- runner.registerAsNotApplicable('N/A - User requested No Change in economizer operation.')
85
- return true
86
- end
87
-
88
- # short def to make numbers pretty (converts 4125001.25641 to 4,125,001.26 or 4,125,001). The definition be called through this measure
89
- def neat_numbers(number, roundto = 2) # round to 0 or 2)
90
- if roundto == 2
91
- number = format '%.2f', number
92
- else
93
- number = number.round
94
- end
95
- # regex to add commas
96
- number.to_s.reverse.gsub(/([0-9]{3}(?=([0-9])))/, '\\1,').reverse
97
- end
98
-
99
- # info for initial condition
100
- air_loops_changed = []
101
-
102
- # loop through air loops
103
- model.getAirLoopHVACs.each do |air_loop|
104
- # find AirLoopHVACOutdoorAirSystem on loop
105
- air_loop.supplyComponents.each do |supply_component|
106
- hVACComponent = supply_component.to_AirLoopHVACOutdoorAirSystem
107
- if !hVACComponent.empty?
108
- hVACComponent = hVACComponent.get
109
-
110
- # get ControllerOutdoorAir
111
- controller_oa = hVACComponent.getControllerOutdoorAir
112
-
113
- # get ControllerMechanicalVentilation
114
- controller_mv = controller_oa.controllerMechanicalVentilation
115
-
116
- if dcv_type == 'EnableDCV'
117
- # check if demand control is enabled, if not, then enable it
118
- if controller_mv.demandControlledVentilation == true
119
- runner.registerInfo("#{air_loop.name} already has DCV enabled.")
120
- else
121
- controller_mv.setDemandControlledVentilation(true)
122
- runner.registerInfo("Enabling DCV for #{air_loop.name}.")
123
- air_loops_changed << air_loop
124
- end
125
- elsif dcv_type == 'DisableDCV'
126
- # check if demand control is disabled, if not, then disabled it
127
- if controller_mv.demandControlledVentilation == false
128
- runner.registerInfo("#{air_loop.name} already has DCV disabled.")
129
- else
130
- controller_mv.setDemandControlledVentilation(false)
131
- runner.registerInfo("Disabling DCV for #{air_loop.name}.")
132
- air_loops_changed << air_loop
133
- end
134
- end
135
-
136
- end
137
- end
138
- end
139
-
140
- # Report N/A if none of the air loops were changed
141
- if air_loops_changed.empty?
142
- runner.registerAsNotApplicable('No air loops had DCV enabled or disabled.')
143
- return true
144
- end
145
-
146
- # Report final condition of model
147
- runner.registerFinalCondition("#{air_loops_changed.size} air loops now have demand controlled ventilation enabled.")
148
-
149
- return true
150
- end
151
- end
152
-
153
- # this allows the measure to be use by the application
154
- EnableDemandControlledVentilation.new.registerWithApplication