openstudio-common-measures 0.2.0 → 0.4.0

Sign up to get free protection for your applications and to get access to all the features.
Files changed (524) hide show
  1. checksums.yaml +4 -4
  2. data/.gitignore +1 -0
  3. data/CHANGELOG.md +82 -0
  4. data/Jenkinsfile +2 -1
  5. data/LICENSE.md +1 -1
  6. data/Rakefile +17 -0
  7. data/doc_templates/LICENSE.md +1 -1
  8. data/doc_templates/copyright_erb.txt +1 -1
  9. data/doc_templates/copyright_js.txt +1 -1
  10. data/doc_templates/copyright_ruby.txt +1 -1
  11. data/lib/measures/AddCostPerAreaToConstruction/LICENSE.md +1 -1
  12. data/lib/measures/AddCostPerAreaToConstruction/measure.rb +1 -1
  13. data/lib/measures/AddCostPerAreaToConstruction/measure.xml +8 -7
  14. data/lib/measures/AddCostPerFloorAreaToBuilding/LICENSE.md +1 -1
  15. data/lib/measures/AddCostPerFloorAreaToBuilding/measure.rb +1 -1
  16. data/lib/measures/AddCostPerFloorAreaToBuilding/measure.xml +8 -7
  17. data/lib/measures/AddCostPerFloorAreaToElectricEquipment/LICENSE.md +1 -1
  18. data/lib/measures/AddCostPerFloorAreaToElectricEquipment/measure.rb +1 -1
  19. data/lib/measures/AddCostPerFloorAreaToElectricEquipment/measure.xml +8 -7
  20. data/lib/measures/AddCostPerFloorAreaToLights/LICENSE.md +1 -1
  21. data/lib/measures/AddCostPerFloorAreaToLights/measure.rb +1 -1
  22. data/lib/measures/AddCostPerFloorAreaToLights/measure.xml +8 -7
  23. data/lib/measures/AddCostPerFloorAreaUnusedToLights/LICENSE.md +1 -1
  24. data/lib/measures/AddCostPerFloorAreaUnusedToLights/measure.rb +1 -1
  25. data/lib/measures/AddCostPerFloorAreaUnusedToLights/measure.xml +8 -7
  26. data/lib/measures/AddCostToSupplySideHVACComponentByAirLoop/LICENSE.md +1 -1
  27. data/lib/measures/AddCostToSupplySideHVACComponentByAirLoop/measure.rb +1 -1
  28. data/lib/measures/AddCostToSupplySideHVACComponentByAirLoop/measure.xml +9 -8
  29. data/lib/measures/AddCostperAreatoUnusedConstruction/LICENSE.md +1 -1
  30. data/lib/measures/AddCostperAreatoUnusedConstruction/measure.rb +1 -1
  31. data/lib/measures/AddCostperAreatoUnusedConstruction/measure.xml +8 -7
  32. data/lib/measures/AddExteriorLights/LICENSE.md +1 -1
  33. data/lib/measures/AddExteriorLights/measure.rb +1 -1
  34. data/lib/measures/AddExteriorLights/measure.xml +8 -7
  35. data/lib/measures/AddMeter/LICENSE.md +1 -1
  36. data/lib/measures/AddMeter/measure.rb +1 -1
  37. data/lib/measures/AddMeter/measure.xml +8 -7
  38. data/lib/measures/AddOutputDiagnostics/LICENSE.md +1 -1
  39. data/lib/measures/AddOutputDiagnostics/measure.rb +1 -1
  40. data/lib/measures/AddOutputDiagnostics/measure.xml +8 -7
  41. data/lib/measures/AddOutputVariable/LICENSE.md +1 -1
  42. data/lib/measures/AddOutputVariable/measure.rb +1 -1
  43. data/lib/measures/AddOutputVariable/measure.xml +8 -7
  44. data/lib/measures/AddSimplePvToShadingSurfacesByType/LICENSE.md +1 -1
  45. data/lib/measures/AddSimplePvToShadingSurfacesByType/measure.rb +1 -1
  46. data/lib/measures/AddSimplePvToShadingSurfacesByType/measure.xml +8 -7
  47. data/lib/measures/AdjustSystemEfficiencies/LICENSE.md +1 -1
  48. data/lib/measures/AdjustSystemEfficiencies/measure.rb +1 -1
  49. data/lib/measures/AdjustSystemEfficiencies/measure.xml +7 -6
  50. data/lib/measures/AdjustThermostatSetpointsByDegrees/LICENSE.md +1 -1
  51. data/lib/measures/AdjustThermostatSetpointsByDegrees/measure.rb +1 -1
  52. data/lib/measures/AdjustThermostatSetpointsByDegrees/measure.xml +8 -7
  53. data/lib/measures/ChangeBuildingLocation/LICENSE.md +1 -1
  54. data/lib/measures/ChangeBuildingLocation/measure.rb +3 -3
  55. data/lib/measures/ChangeBuildingLocation/measure.xml +15 -15
  56. data/lib/measures/ChangeBuildingLocation/resources/epw.rb +1 -1
  57. data/lib/measures/ChangeBuildingLocation/resources/stat_file.rb +1 -1
  58. data/lib/measures/EnableIdealAirLoadsForAllZones/LICENSE.md +1 -1
  59. data/lib/measures/EnableIdealAirLoadsForAllZones/measure.rb +1 -1
  60. data/lib/measures/EnableIdealAirLoadsForAllZones/measure.xml +9 -8
  61. data/lib/measures/ExportScheduleCSV/LICENSE.md +1 -1
  62. data/lib/measures/ExportScheduleCSV/measure.rb +2 -2
  63. data/lib/measures/ExportScheduleCSV/measure.xml +13 -12
  64. data/lib/measures/ImportEnvelopeAndInternalLoadsFromIdf/LICENSE.md +1 -1
  65. data/lib/measures/ImportEnvelopeAndInternalLoadsFromIdf/measure.rb +1 -1
  66. data/lib/measures/ImportEnvelopeAndInternalLoadsFromIdf/measure.xml +9 -8
  67. data/lib/measures/MeterFlodPlot/LICENSE.md +1 -1
  68. data/lib/measures/MeterFlodPlot/measure.rb +2 -2
  69. data/lib/measures/MeterFlodPlot/measure.xml +13 -12
  70. data/lib/measures/ModifyEnergyPlusCoilCoolingDXSingleSpeedObjects/LICENSE.md +1 -1
  71. data/lib/measures/ModifyEnergyPlusCoilCoolingDXSingleSpeedObjects/measure.rb +1 -1
  72. data/lib/measures/ModifyEnergyPlusCoilCoolingDXSingleSpeedObjects/measure.xml +8 -7
  73. data/lib/measures/ModifyEnergyPlusFanVariableVolumeObjects/LICENSE.md +1 -1
  74. data/lib/measures/ModifyEnergyPlusFanVariableVolumeObjects/measure.rb +1 -1
  75. data/lib/measures/ModifyEnergyPlusFanVariableVolumeObjects/measure.xml +8 -7
  76. data/lib/measures/PredictedMeanVote/LICENSE.md +1 -1
  77. data/lib/measures/PredictedMeanVote/measure.rb +1 -1
  78. data/lib/measures/PredictedMeanVote/measure.xml +14 -13
  79. data/lib/measures/RemoveInternalLoadsDirectlyAssignedToSpaces/LICENSE.md +1 -1
  80. data/lib/measures/RemoveInternalLoadsDirectlyAssignedToSpaces/measure.rb +1 -1
  81. data/lib/measures/RemoveInternalLoadsDirectlyAssignedToSpaces/measure.xml +9 -8
  82. data/lib/measures/RemoveUnusedDefaultProfiles/LICENSE.md +1 -1
  83. data/lib/measures/RemoveUnusedDefaultProfiles/measure.rb +1 -1
  84. data/lib/measures/RemoveUnusedDefaultProfiles/measure.xml +9 -8
  85. data/lib/measures/ReplaceExteriorWindowConstruction/LICENSE.md +1 -1
  86. data/lib/measures/ReplaceExteriorWindowConstruction/measure.rb +1 -1
  87. data/lib/measures/ReplaceExteriorWindowConstruction/measure.xml +11 -10
  88. data/lib/measures/ReplaceThermostatSchedules/LICENSE.md +1 -1
  89. data/lib/measures/ReplaceThermostatSchedules/measure.rb +1 -1
  90. data/lib/measures/ReplaceThermostatSchedules/measure.xml +12 -11
  91. data/lib/measures/ReportModelChanges/LICENSE.md +1 -1
  92. data/lib/measures/ReportModelChanges/measure.rb +1 -1
  93. data/lib/measures/ReportModelChanges/measure.xml +5 -5
  94. data/lib/measures/RunPeriod/LICENSE.md +1 -1
  95. data/lib/measures/RunPeriod/measure.rb +1 -1
  96. data/lib/measures/RunPeriod/measure.xml +19 -18
  97. data/lib/measures/RunPeriodMultiple/LICENSE.md +1 -1
  98. data/lib/measures/RunPeriodMultiple/measure.rb +1 -1
  99. data/lib/measures/RunPeriodMultiple/measure.xml +12 -11
  100. data/lib/measures/ServerDirectoryCleanup/LICENSE.md +1 -1
  101. data/lib/measures/ServerDirectoryCleanup/README.md +97 -3
  102. data/lib/measures/ServerDirectoryCleanup/measure.rb +2 -2
  103. data/lib/measures/ServerDirectoryCleanup/measure.xml +20 -69
  104. data/lib/measures/SetCOPforSingleSpeedDXCoolingUnits/LICENSE.md +1 -1
  105. data/lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.rb +1 -1
  106. data/lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.xml +10 -9
  107. data/lib/measures/SetCOPforTwoSpeedDXCoolingUnits/LICENSE.md +1 -1
  108. data/lib/measures/SetCOPforTwoSpeedDXCoolingUnits/measure.rb +1 -1
  109. data/lib/measures/SetCOPforTwoSpeedDXCoolingUnits/measure.xml +10 -9
  110. data/lib/measures/SetEnergyPlusInfiltrationFlowRatePerFloorArea/LICENSE.md +1 -1
  111. data/lib/measures/SetEnergyPlusInfiltrationFlowRatePerFloorArea/measure.rb +1 -1
  112. data/lib/measures/SetEnergyPlusInfiltrationFlowRatePerFloorArea/measure.xml +8 -7
  113. data/lib/measures/SetEnergyPlusLightObjectsLPD/LICENSE.md +1 -1
  114. data/lib/measures/SetEnergyPlusLightObjectsLPD/measure.rb +1 -1
  115. data/lib/measures/SetEnergyPlusLightObjectsLPD/measure.xml +8 -7
  116. data/lib/measures/SetEnergyPlusMinimumOutdoorAirFlowRate/LICENSE.md +1 -1
  117. data/lib/measures/SetEnergyPlusMinimumOutdoorAirFlowRate/measure.rb +1 -1
  118. data/lib/measures/SetEnergyPlusMinimumOutdoorAirFlowRate/measure.xml +8 -7
  119. data/lib/measures/SetGasBurnerEfficiency/LICENSE.md +1 -1
  120. data/lib/measures/SetGasBurnerEfficiency/measure.rb +1 -1
  121. data/lib/measures/SetGasBurnerEfficiency/measure.xml +10 -9
  122. data/lib/measures/SetLifecycleCostParameters/LICENSE.md +1 -1
  123. data/lib/measures/SetLifecycleCostParameters/measure.rb +1 -1
  124. data/lib/measures/SetLifecycleCostParameters/measure.xml +8 -7
  125. data/lib/measures/SetLightingLoadsByLPD/LICENSE.md +1 -1
  126. data/lib/measures/SetLightingLoadsByLPD/measure.rb +1 -1
  127. data/lib/measures/SetLightingLoadsByLPD/measure.xml +10 -9
  128. data/lib/measures/SetSpaceInfiltrationByExteriorSurfaceArea/LICENSE.md +1 -1
  129. data/lib/measures/SetSpaceInfiltrationByExteriorSurfaceArea/measure.rb +1 -1
  130. data/lib/measures/SetSpaceInfiltrationByExteriorSurfaceArea/measure.xml +20 -19
  131. data/lib/measures/SetThermostatSchedules/LICENSE.md +1 -1
  132. data/lib/measures/SetThermostatSchedules/measure.rb +1 -1
  133. data/lib/measures/SetThermostatSchedules/measure.xml +12 -11
  134. data/lib/measures/ShiftScheduleProfileTime/LICENSE.md +1 -1
  135. data/lib/measures/ShiftScheduleProfileTime/measure.rb +1 -1
  136. data/lib/measures/ShiftScheduleProfileTime/measure.xml +10 -9
  137. data/lib/measures/SwapLightsDefinition/LICENSE.md +1 -1
  138. data/lib/measures/SwapLightsDefinition/measure.rb +1 -1
  139. data/lib/measures/SwapLightsDefinition/measure.xml +10 -9
  140. data/lib/measures/UnmetLoadHoursTroubleshooting/LICENSE.md +1 -1
  141. data/lib/measures/UnmetLoadHoursTroubleshooting/README.md +9 -3
  142. data/lib/measures/UnmetLoadHoursTroubleshooting/measure.rb +2 -2
  143. data/lib/measures/UnmetLoadHoursTroubleshooting/measure.xml +72 -23
  144. data/lib/measures/VentilationQAQC/LICENSE.md +1 -1
  145. data/lib/measures/VentilationQAQC/README.md +9 -3
  146. data/lib/measures/VentilationQAQC/measure.rb +53 -46
  147. data/lib/measures/VentilationQAQC/measure.xml +24 -29
  148. data/lib/measures/ZoneReport/LICENSE.md +1 -1
  149. data/lib/measures/ZoneReport/README.md +2 -2
  150. data/lib/measures/ZoneReport/measure.rb +2 -2
  151. data/lib/measures/ZoneReport/measure.xml +16 -17
  152. data/lib/measures/add_ems_to_control_ev_charging/LICENSE.MD.txt +15 -0
  153. data/lib/measures/{AddDaylightSensors → add_ems_to_control_ev_charging}/LICENSE.md +1 -1
  154. data/lib/measures/add_ems_to_control_ev_charging/README.md +29 -0
  155. data/lib/measures/add_ems_to_control_ev_charging/measure.rb +289 -0
  156. data/lib/measures/add_ems_to_control_ev_charging/measure.xml +91 -0
  157. data/lib/measures/add_ev_load/LICENSE.MD.txt +15 -0
  158. data/lib/measures/{EnableEconomizerControl → add_ev_load}/LICENSE.md +1 -1
  159. data/lib/measures/add_ev_load/README.md +34 -0
  160. data/lib/measures/add_ev_load/measure.rb +331 -0
  161. data/lib/measures/add_ev_load/measure.xml +348 -0
  162. data/lib/measures/add_ev_load/resources/PSN_BuildingKey.csv +104 -0
  163. data/lib/measures/add_ev_load/resources/PSN_BuildingKey_v2.csv +104 -0
  164. data/lib/measures/add_ev_load/resources/chg1_dow1_flex1.csv +96 -0
  165. data/lib/measures/add_ev_load/resources/chg1_dow1_flex2.csv +96 -0
  166. data/lib/measures/add_ev_load/resources/chg1_dow1_flex3.csv +96 -0
  167. data/lib/measures/add_ev_load/resources/chg1_dow2_flex1.csv +96 -0
  168. data/lib/measures/add_ev_load/resources/chg1_dow2_flex2.csv +96 -0
  169. data/lib/measures/add_ev_load/resources/chg1_dow2_flex3.csv +96 -0
  170. data/lib/measures/add_ev_load/resources/chg1_dow3_flex1.csv +96 -0
  171. data/lib/measures/add_ev_load/resources/chg1_dow3_flex2.csv +96 -0
  172. data/lib/measures/add_ev_load/resources/chg1_dow3_flex3.csv +96 -0
  173. data/lib/measures/add_ev_load/resources/chg2_dow1_flex1.csv +96 -0
  174. data/lib/measures/add_ev_load/resources/chg2_dow1_flex2.csv +96 -0
  175. data/lib/measures/add_ev_load/resources/chg2_dow1_flex3.csv +96 -0
  176. data/lib/measures/add_ev_load/resources/chg2_dow2_flex1.csv +96 -0
  177. data/lib/measures/add_ev_load/resources/chg2_dow2_flex2.csv +96 -0
  178. data/lib/measures/add_ev_load/resources/chg2_dow2_flex3.csv +96 -0
  179. data/lib/measures/add_ev_load/resources/chg2_dow3_flex1.csv +96 -0
  180. data/lib/measures/add_ev_load/resources/chg2_dow3_flex2.csv +96 -0
  181. data/lib/measures/add_ev_load/resources/chg2_dow3_flex3.csv +96 -0
  182. data/lib/measures/add_ev_load/resources/chg3_dow1_flex1.csv +96 -0
  183. data/lib/measures/add_ev_load/resources/chg3_dow1_flex2.csv +96 -0
  184. data/lib/measures/add_ev_load/resources/chg3_dow1_flex3.csv +96 -0
  185. data/lib/measures/add_ev_load/resources/chg3_dow2_flex1.csv +96 -0
  186. data/lib/measures/add_ev_load/resources/chg3_dow2_flex2.csv +96 -0
  187. data/lib/measures/add_ev_load/resources/chg3_dow2_flex3.csv +96 -0
  188. data/lib/measures/add_ev_load/resources/chg3_dow3_flex1.csv +96 -0
  189. data/lib/measures/add_ev_load/resources/chg3_dow3_flex2.csv +96 -0
  190. data/lib/measures/add_ev_load/resources/chg3_dow3_flex3.csv +96 -0
  191. data/lib/measures/add_ev_load/resources/fast_charge_15min_Saturday.csv +96 -0
  192. data/lib/measures/add_ev_load/resources/fast_charge_15min_Sunday.csv +96 -0
  193. data/lib/measures/add_ev_load/resources/fast_charge_15min_Weekday.csv +96 -0
  194. data/lib/measures/add_rooftop_pv/LICENSE.md +1 -1
  195. data/lib/measures/add_rooftop_pv/measure.rb +1 -1
  196. data/lib/measures/add_rooftop_pv/measure.xml +5 -5
  197. data/lib/measures/add_zone_mixing_object/LICENSE.md +1 -1
  198. data/lib/measures/add_zone_mixing_object/measure.rb +1 -1
  199. data/lib/measures/add_zone_mixing_object/measure.xml +8 -7
  200. data/lib/measures/add_zone_ventilation_design_flow_rate_object/LICENSE.md +1 -1
  201. data/lib/measures/add_zone_ventilation_design_flow_rate_object/measure.rb +1 -1
  202. data/lib/measures/add_zone_ventilation_design_flow_rate_object/measure.xml +8 -7
  203. data/lib/measures/air_wall_zone_mixing/LICENSE.md +1 -1
  204. data/lib/measures/air_wall_zone_mixing/measure.rb +1 -1
  205. data/lib/measures/air_wall_zone_mixing/measure.xml +5 -5
  206. data/lib/measures/envelope_and_internal_load_breakdown/LICENSE.md +1 -1
  207. data/lib/measures/envelope_and_internal_load_breakdown/README.md +4 -3
  208. data/lib/measures/envelope_and_internal_load_breakdown/measure.rb +8 -5
  209. data/lib/measures/envelope_and_internal_load_breakdown/measure.xml +18 -19
  210. data/lib/measures/envelope_and_internal_load_breakdown/resources/os_lib_reporting_envelope_and_internal_loads_breakdown.rb +1 -1
  211. data/lib/measures/envelope_and_internal_load_breakdown/resources/report.html.erb +5 -1
  212. data/lib/measures/example_report/LICENSE.md +1 -1
  213. data/lib/measures/example_report/README.md +27 -5
  214. data/lib/measures/example_report/measure.rb +8 -5
  215. data/lib/measures/example_report/measure.xml +19 -32
  216. data/lib/measures/example_report/resources/os_lib_reporting_example.rb +1 -1
  217. data/lib/measures/example_report/resources/report.html.erb +5 -1
  218. data/lib/measures/gem_env_report/LICENSE.md +1 -1
  219. data/lib/measures/gem_env_report/measure.rb +1 -1
  220. data/lib/measures/gem_env_report/measure.xml +14 -13
  221. data/lib/measures/gem_env_report/resources/gem_env_info.rb +1 -1
  222. data/lib/measures/gem_env_report/resources/openstudio_info.rb +1 -1
  223. data/lib/measures/gem_env_report/resources/run_gem_env_info.rb +1 -1
  224. data/lib/measures/gem_env_report/resources/run_openstudio_info.rb +1 -1
  225. data/lib/measures/generic_qaqc/LICENSE.md +1 -1
  226. data/lib/measures/generic_qaqc/README.md +187 -5
  227. data/lib/measures/generic_qaqc/measure.rb +7 -2
  228. data/lib/measures/generic_qaqc/measure.xml +54 -130
  229. data/lib/measures/generic_qaqc/resources/CreateResults.rb +1 -1
  230. data/lib/measures/generic_qaqc/resources/check_air_sys_temps.rb +1 -1
  231. data/lib/measures/generic_qaqc/resources/check_calibration.rb +1 -1
  232. data/lib/measures/generic_qaqc/resources/check_cond_zns.rb +1 -1
  233. data/lib/measures/generic_qaqc/resources/check_domestic_hot_water.rb +1 -1
  234. data/lib/measures/generic_qaqc/resources/check_envelope_conductance.rb +8 -2
  235. data/lib/measures/generic_qaqc/resources/check_eui_by_end_use.rb +11 -12
  236. data/lib/measures/generic_qaqc/resources/check_eui_reasonableness.rb +1 -1
  237. data/lib/measures/generic_qaqc/resources/check_fan_pwr.rb +1 -1
  238. data/lib/measures/generic_qaqc/resources/check_internal_loads.rb +1 -1
  239. data/lib/measures/generic_qaqc/resources/check_mech_sys_capacity.rb +1 -1
  240. data/lib/measures/generic_qaqc/resources/check_mech_sys_efficiency.rb +1 -1
  241. data/lib/measures/generic_qaqc/resources/check_mech_sys_part_load_eff.rb +1 -1
  242. data/lib/measures/generic_qaqc/resources/check_mech_sys_type.rb +1 -1
  243. data/lib/measures/generic_qaqc/resources/check_part_loads.rb +1 -1
  244. data/lib/measures/generic_qaqc/resources/check_placeholder.rb +1 -1
  245. data/lib/measures/generic_qaqc/resources/check_plant_cap.rb +1 -1
  246. data/lib/measures/generic_qaqc/resources/check_plant_temps.rb +1 -1
  247. data/lib/measures/generic_qaqc/resources/check_plenum_loads.rb +1 -1
  248. data/lib/measures/generic_qaqc/resources/check_pump_pwr.rb +1 -1
  249. data/lib/measures/generic_qaqc/resources/check_sch_coord.rb +1 -1
  250. data/lib/measures/generic_qaqc/resources/check_schedules.rb +1 -1
  251. data/lib/measures/generic_qaqc/resources/check_simultaneous_heating_and_cooling.rb +1 -1
  252. data/lib/measures/generic_qaqc/resources/check_supply_air_and_thermostat_temp_difference.rb +1 -1
  253. data/lib/measures/generic_qaqc/resources/check_weather_files.rb +1 -1
  254. data/lib/measures/generic_qaqc/resources/os_lib_reporting_qaqc.rb +1 -1
  255. data/lib/measures/generic_qaqc/resources/report.html.erb +5 -1
  256. data/lib/measures/get_site_from_building_component_library/LICENSE.md +1 -1
  257. data/lib/measures/get_site_from_building_component_library/measure.rb +1 -1
  258. data/lib/measures/get_site_from_building_component_library/measure.xml +6 -6
  259. data/lib/measures/hvac_psychrometric_chart/LICENSE.md +1 -1
  260. data/lib/measures/hvac_psychrometric_chart/README.md +11 -5
  261. data/lib/measures/hvac_psychrometric_chart/measure.rb +2 -2
  262. data/lib/measures/hvac_psychrometric_chart/measure.xml +13 -19
  263. data/lib/measures/hvac_psychrometric_chart/resources/report.html.erb +5 -1
  264. data/lib/measures/inject_idf_objects/LICENSE.md +1 -1
  265. data/lib/measures/inject_idf_objects/measure.rb +1 -1
  266. data/lib/measures/inject_idf_objects/measure.xml +29 -28
  267. data/lib/measures/openstudio_results/LICENSE.md +1 -1
  268. data/lib/measures/openstudio_results/README.md +200 -6
  269. data/lib/measures/openstudio_results/measure.rb +20 -14
  270. data/lib/measures/openstudio_results/measure.xml +210 -302
  271. data/lib/measures/openstudio_results/resources/Siz.AirConditionerVariableRefrigerantFlow.rb +1 -1
  272. data/lib/measures/openstudio_results/resources/Siz.AirLoopHVAC.rb +1 -1
  273. data/lib/measures/openstudio_results/resources/Siz.AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass.rb +1 -1
  274. data/lib/measures/openstudio_results/resources/Siz.AirLoopHVACUnitaryHeatPumpAirToAir.rb +1 -1
  275. data/lib/measures/openstudio_results/resources/Siz.AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed.rb +1 -1
  276. data/lib/measures/openstudio_results/resources/Siz.AirLoopHVACUnitarySystem.rb +1 -1
  277. data/lib/measures/openstudio_results/resources/Siz.AirTerminalDualDuctVAV.rb +1 -1
  278. data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctConstantVolumeCooledBeam.rb +1 -1
  279. data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctConstantVolumeFourPipeInduction.rb +1 -1
  280. data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctConstantVolumeReheat.rb +1 -1
  281. data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
  282. data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctSeriesPIUReheat.rb +1 -1
  283. data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctUncontrolled.rb +1 -1
  284. data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctVAVHeatAndCoolNoReheat.rb +1 -1
  285. data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctVAVHeatAndCoolReheat.rb +1 -1
  286. data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctVAVNoReheat.rb +1 -1
  287. data/lib/measures/openstudio_results/resources/Siz.AirTerminalSingleDuctVAVReheat.rb +1 -1
  288. data/lib/measures/openstudio_results/resources/Siz.BoilerHotWater.rb +1 -1
  289. data/lib/measures/openstudio_results/resources/Siz.BoilerSteam.rb +1 -1
  290. data/lib/measures/openstudio_results/resources/Siz.ChillerAbsorption.rb +1 -1
  291. data/lib/measures/openstudio_results/resources/Siz.ChillerAbsorptionIndirect.rb +1 -1
  292. data/lib/measures/openstudio_results/resources/Siz.ChillerElectricEIR.rb +1 -1
  293. data/lib/measures/openstudio_results/resources/Siz.ChillerHeaterPerformanceElectricEIR.rb +1 -1
  294. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXMultiSpeed.rb +1 -1
  295. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXMultiSpeedStageData.rb +1 -1
  296. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXSingleSpeed.rb +1 -1
  297. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXTwoSpeed.rb +1 -1
  298. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXTwoStageWithHumidityControlMode.rb +1 -1
  299. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXVariableRefrigerantFlow.rb +1 -1
  300. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXVariableSpeed.rb +1 -1
  301. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingDXVariableSpeedSpeedData.rb +1 -1
  302. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingLowTempRadiantVarFlow.rb +1 -1
  303. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingWater.rb +1 -1
  304. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
  305. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingWaterToAirHeatPumpVariableSpeedEquationFit.rb +1 -1
  306. data/lib/measures/openstudio_results/resources/Siz.CoilCoolingWaterToAirHeatPumpVariableSpeedEquationFitSpeedData.rb +1 -1
  307. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXMultiSpeed.rb +1 -1
  308. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXMultiSpeedStageData.rb +1 -1
  309. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXSingleSpeed.rb +1 -1
  310. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXVariableRefrigerantFlow.rb +1 -1
  311. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXVariableSpeed.rb +1 -1
  312. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDXVariableSpeedSpeedData.rb +1 -1
  313. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingDesuperheater.rb +1 -1
  314. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingElectric.rb +1 -1
  315. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingGas.rb +1 -1
  316. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingGasMultiStage.rb +1 -1
  317. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingGasMultiStageStageData.rb +1 -1
  318. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingLowTempRadiantVarFlow.rb +1 -1
  319. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWater.rb +1 -1
  320. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWaterBaseboard.rb +1 -1
  321. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWaterBaseboardRadiant.rb +1 -1
  322. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
  323. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWaterToAirHeatPumpVariableSpeedEquationFit.rb +1 -1
  324. data/lib/measures/openstudio_results/resources/Siz.CoilHeatingWaterToAirHeatPumpVariableSpeedEquationFitSpeedData.rb +1 -1
  325. data/lib/measures/openstudio_results/resources/Siz.CoilPerformanceDXCooling.rb +1 -1
  326. data/lib/measures/openstudio_results/resources/Siz.CoilSystemCoolingDXHeatExchangerAssisted.rb +1 -1
  327. data/lib/measures/openstudio_results/resources/Siz.CoilSystemCoolingWaterHeatExchangerAssisted.rb +1 -1
  328. data/lib/measures/openstudio_results/resources/Siz.CoilWaterHeatingAirToWaterHeatPump.rb +1 -1
  329. data/lib/measures/openstudio_results/resources/Siz.CoilWaterHeatingAirToWaterHeatPumpWrapped.rb +1 -1
  330. data/lib/measures/openstudio_results/resources/Siz.CoilWaterHeatingDesuperheater.rb +1 -1
  331. data/lib/measures/openstudio_results/resources/Siz.ControllerOutdoorAir.rb +1 -1
  332. data/lib/measures/openstudio_results/resources/Siz.CoolingTowerSingleSpeed.rb +1 -1
  333. data/lib/measures/openstudio_results/resources/Siz.CoolingTowerTwoSpeed.rb +1 -1
  334. data/lib/measures/openstudio_results/resources/Siz.CoolingTowerVariableSpeed.rb +1 -1
  335. data/lib/measures/openstudio_results/resources/Siz.DistrictCooling.rb +1 -1
  336. data/lib/measures/openstudio_results/resources/Siz.DistrictHeating.rb +1 -1
  337. data/lib/measures/openstudio_results/resources/Siz.ElectricLoadCenterInverterLookUpTable.rb +1 -1
  338. data/lib/measures/openstudio_results/resources/Siz.ElectricLoadCenterInverterSimple.rb +1 -1
  339. data/lib/measures/openstudio_results/resources/Siz.ElectricLoadCenterStorageConverter.rb +1 -1
  340. data/lib/measures/openstudio_results/resources/Siz.ElectricLoadCenterStorageSimple.rb +1 -1
  341. data/lib/measures/openstudio_results/resources/Siz.EvaporativeCoolerDirectResearchSpecial.rb +1 -1
  342. data/lib/measures/openstudio_results/resources/Siz.EvaporativeCoolerIndirectResearchSpecial.rb +1 -1
  343. data/lib/measures/openstudio_results/resources/Siz.EvaporativeFluidCoolerSingleSpeed.rb +1 -1
  344. data/lib/measures/openstudio_results/resources/Siz.EvaporativeFluidCoolerTwoSpeed.rb +1 -1
  345. data/lib/measures/openstudio_results/resources/Siz.FanConstantVolume.rb +1 -1
  346. data/lib/measures/openstudio_results/resources/Siz.FanOnOff.rb +1 -1
  347. data/lib/measures/openstudio_results/resources/Siz.FanVariableVolume.rb +1 -1
  348. data/lib/measures/openstudio_results/resources/Siz.FanZoneExhaust.rb +1 -1
  349. data/lib/measures/openstudio_results/resources/Siz.FluidCoolerSingleSpeed.rb +1 -1
  350. data/lib/measures/openstudio_results/resources/Siz.FluidCoolerTwoSpeed.rb +1 -1
  351. data/lib/measures/openstudio_results/resources/Siz.GeneratorFuelCellElectricalStorage.rb +1 -1
  352. data/lib/measures/openstudio_results/resources/Siz.GeneratorFuelCellInverter.rb +1 -1
  353. data/lib/measures/openstudio_results/resources/Siz.GeneratorFuelCellPowerModule.rb +1 -1
  354. data/lib/measures/openstudio_results/resources/Siz.GeneratorMicroTurbine.rb +1 -1
  355. data/lib/measures/openstudio_results/resources/Siz.GeneratorMicroTurbineHeatRecovery.rb +1 -1
  356. data/lib/measures/openstudio_results/resources/Siz.HVACComponent.rb +1 -1
  357. data/lib/measures/openstudio_results/resources/Siz.HeaderedPumpsConstantSpeed.rb +1 -1
  358. data/lib/measures/openstudio_results/resources/Siz.HeaderedPumpsVariableSpeed.rb +1 -1
  359. data/lib/measures/openstudio_results/resources/Siz.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
  360. data/lib/measures/openstudio_results/resources/Siz.HeatExchangerFluidToFluid.rb +1 -1
  361. data/lib/measures/openstudio_results/resources/Siz.HeatPumpWaterToWaterEquationFitCooling.rb +1 -1
  362. data/lib/measures/openstudio_results/resources/Siz.HeatPumpWaterToWaterEquationFitHeating.rb +1 -1
  363. data/lib/measures/openstudio_results/resources/Siz.HumidifierSteamElectric.rb +1 -1
  364. data/lib/measures/openstudio_results/resources/Siz.Model.rb +1 -1
  365. data/lib/measures/openstudio_results/resources/Siz.ModelObject.rb +1 -1
  366. data/lib/measures/openstudio_results/resources/Siz.PhotovoltaicPerformanceSimple.rb +1 -1
  367. data/lib/measures/openstudio_results/resources/Siz.PlantComponentTemperatureSource.rb +1 -1
  368. data/lib/measures/openstudio_results/resources/Siz.PlantLoop.rb +1 -1
  369. data/lib/measures/openstudio_results/resources/Siz.PumpConstantSpeed.rb +1 -1
  370. data/lib/measures/openstudio_results/resources/Siz.PumpVariableSpeed.rb +1 -1
  371. data/lib/measures/openstudio_results/resources/Siz.RefrigerationSecondarySystem.rb +1 -1
  372. data/lib/measures/openstudio_results/resources/Siz.RefrigerationSystem.rb +1 -1
  373. data/lib/measures/openstudio_results/resources/Siz.RefrigerationTranscriticalSystem.rb +1 -1
  374. data/lib/measures/openstudio_results/resources/Siz.SizingSystem.rb +1 -1
  375. data/lib/measures/openstudio_results/resources/Siz.SolarCollectorFlatPlatePhotovoltaicThermal.rb +1 -1
  376. data/lib/measures/openstudio_results/resources/Siz.SolarCollectorPerformancePhotovoltaicThermalSimple.rb +1 -1
  377. data/lib/measures/openstudio_results/resources/Siz.ThermalStorageChilledWaterStratified.rb +1 -1
  378. data/lib/measures/openstudio_results/resources/Siz.WaterHeaterHeatPump.rb +1 -1
  379. data/lib/measures/openstudio_results/resources/Siz.WaterHeaterHeatPumpWrappedCondenser.rb +1 -1
  380. data/lib/measures/openstudio_results/resources/Siz.WaterHeaterMixed.rb +1 -1
  381. data/lib/measures/openstudio_results/resources/Siz.WaterHeaterStratified.rb +1 -1
  382. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACBaseboardConvectiveElectric.rb +1 -1
  383. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACBaseboardConvectiveWater.rb +1 -1
  384. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACBaseboardRadiantConvectiveElectric.rb +1 -1
  385. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACBaseboardRadiantConvectiveWater.rb +1 -1
  386. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACEnergyRecoveryVentilator.rb +1 -1
  387. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACFourPipeFanCoil.rb +1 -1
  388. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACHighTemperatureRadiant.rb +1 -1
  389. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACIdealLoadsAirSystem.rb +1 -1
  390. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACLowTempRadiantConstFlow.rb +1 -1
  391. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACLowTempRadiantVarFlow.rb +1 -1
  392. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACPackagedTerminalAirConditioner.rb +1 -1
  393. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACPackagedTerminalHeatPump.rb +1 -1
  394. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +1 -1
  395. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACUnitHeater.rb +1 -1
  396. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACUnitVentilator.rb +1 -1
  397. data/lib/measures/openstudio_results/resources/Siz.ZoneHVACWaterToAirHeatPump.rb +1 -1
  398. data/lib/measures/openstudio_results/resources/Siz.ZoneVentilationDesignFlowRate.rb +1 -1
  399. data/lib/measures/openstudio_results/resources/os_lib_reporting.rb +117 -39
  400. data/lib/measures/openstudio_results/resources/report.html.erb +5 -1
  401. data/lib/measures/remove_orphan_objects_and_unused_resources/LICENSE.md +1 -1
  402. data/lib/measures/remove_orphan_objects_and_unused_resources/measure.rb +1 -1
  403. data/lib/measures/remove_orphan_objects_and_unused_resources/measure.xml +8 -7
  404. data/lib/measures/set_electric_equipment_loads_by_epd/LICENSE.md +1 -1
  405. data/lib/measures/set_electric_equipment_loads_by_epd/measure.rb +1 -1
  406. data/lib/measures/set_electric_equipment_loads_by_epd/measure.xml +10 -9
  407. data/lib/measures/set_exterior_walls_and_floors_to_adiabatic/LICENSE.md +1 -1
  408. data/lib/measures/set_exterior_walls_and_floors_to_adiabatic/README.md +16 -0
  409. data/lib/measures/set_exterior_walls_and_floors_to_adiabatic/measure.rb +33 -2
  410. data/lib/measures/set_exterior_walls_and_floors_to_adiabatic/measure.xml +33 -8
  411. data/lib/measures/set_run_period/LICENSE.md +1 -1
  412. data/lib/measures/set_run_period/measure.rb +1 -1
  413. data/lib/measures/set_run_period/measure.xml +5 -5
  414. data/lib/measures/set_space_infiltration_per_exterior_area/LICENSE.md +1 -1
  415. data/lib/measures/set_space_infiltration_per_exterior_area/measure.rb +1 -1
  416. data/lib/measures/set_space_infiltration_per_exterior_area/measure.xml +8 -7
  417. data/lib/measures/tariff_selection_block/LICENSE.md +1 -1
  418. data/lib/measures/tariff_selection_block/measure.rb +2 -2
  419. data/lib/measures/tariff_selection_block/measure.xml +5 -5
  420. data/lib/measures/tariff_selection_flat/LICENSE.md +1 -1
  421. data/lib/measures/tariff_selection_flat/measure.rb +2 -2
  422. data/lib/measures/tariff_selection_flat/measure.xml +5 -5
  423. data/lib/measures/tariff_selection_generic/LICENSE.md +1 -1
  424. data/lib/measures/tariff_selection_generic/README.md +2 -2
  425. data/lib/measures/tariff_selection_generic/measure.rb +1 -1
  426. data/lib/measures/tariff_selection_generic/measure.xml +25 -25
  427. data/lib/measures/tariff_selection_generic/resources/FlatEnergyCharge-Gas.idf +3 -3
  428. data/lib/measures/tariff_selection_generic/resources/IN-EIAMonthlyRateGas.idf +1 -1
  429. data/lib/measures/tariff_selection_time_and_date_dependant/LICENSE.md +1 -1
  430. data/lib/measures/tariff_selection_time_and_date_dependant/measure.rb +2 -2
  431. data/lib/measures/tariff_selection_time_and_date_dependant/measure.xml +5 -5
  432. data/lib/measures/{ImproveFanBeltEfficiency → view_data}/LICENSE.md +1 -1
  433. data/lib/measures/view_data/README.md +64 -0
  434. data/lib/measures/{AddDaylightSensors → view_data}/README.md.erb +0 -0
  435. data/lib/measures/view_data/measure.rb +454 -0
  436. data/lib/measures/view_data/measure.xml +159 -0
  437. data/lib/measures/view_data/resources/report.html.in +2881 -0
  438. data/lib/measures/view_data/resources/va3c.rb +1025 -0
  439. data/lib/measures/{EnableDemandControlledVentilation → view_model}/LICENSE.md +1 -1
  440. data/lib/measures/view_model/README.md +26 -0
  441. data/lib/measures/{EnableDemandControlledVentilation → view_model}/README.md.erb +0 -0
  442. data/lib/measures/view_model/measure.rb +146 -0
  443. data/lib/measures/view_model/measure.xml +129 -0
  444. data/lib/measures/view_model/resources/report.html.in +2881 -0
  445. data/lib/measures/view_model/resources/va3c.rb +1025 -0
  446. data/lib/openstudio-common-measures.rb +1 -1
  447. data/lib/openstudio/common_measures.rb +1 -1
  448. data/lib/openstudio/common_measures/extension.rb +1 -1
  449. data/lib/openstudio/common_measures/version.rb +2 -2
  450. data/openstudio-common-measures.gemspec +4 -4
  451. metadata +67 -91
  452. data/lib/measures/AddDaylightSensors/README.md +0 -136
  453. data/lib/measures/AddDaylightSensors/measure.rb +0 -521
  454. data/lib/measures/AddDaylightSensors/measure.xml +0 -233
  455. data/lib/measures/EnableDemandControlledVentilation/README.md +0 -32
  456. data/lib/measures/EnableDemandControlledVentilation/measure.rb +0 -154
  457. data/lib/measures/EnableDemandControlledVentilation/measure.xml +0 -99
  458. data/lib/measures/EnableEconomizerControl/README.md +0 -48
  459. data/lib/measures/EnableEconomizerControl/README.md.erb +0 -42
  460. data/lib/measures/EnableEconomizerControl/measure.rb +0 -172
  461. data/lib/measures/EnableEconomizerControl/measure.xml +0 -124
  462. data/lib/measures/ImproveFanBeltEfficiency/README.md +0 -104
  463. data/lib/measures/ImproveFanBeltEfficiency/README.md.erb +0 -42
  464. data/lib/measures/ImproveFanBeltEfficiency/measure.rb +0 -366
  465. data/lib/measures/ImproveFanBeltEfficiency/measure.xml +0 -185
  466. data/lib/measures/ImproveMotorEfficiency/LICENSE.md +0 -27
  467. data/lib/measures/ImproveMotorEfficiency/README.md +0 -104
  468. data/lib/measures/ImproveMotorEfficiency/README.md.erb +0 -42
  469. data/lib/measures/ImproveMotorEfficiency/measure.rb +0 -365
  470. data/lib/measures/ImproveMotorEfficiency/measure.xml +0 -182
  471. data/lib/measures/IncreaseInsulationRValueForExteriorWalls/LICENSE.md +0 -27
  472. data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md +0 -64
  473. data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md.erb +0 -42
  474. data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.rb +0 -422
  475. data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.xml +0 -150
  476. data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/LICENSE.md +0 -27
  477. data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/README.md +0 -32
  478. data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/README.md.erb +0 -42
  479. data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/measure.rb +0 -328
  480. data/lib/measures/IncreaseInsulationRValueForExteriorWallsByPercentage/measure.xml +0 -98
  481. data/lib/measures/IncreaseInsulationRValueForRoofs/LICENSE.md +0 -27
  482. data/lib/measures/IncreaseInsulationRValueForRoofs/README.md +0 -64
  483. data/lib/measures/IncreaseInsulationRValueForRoofs/README.md.erb +0 -42
  484. data/lib/measures/IncreaseInsulationRValueForRoofs/measure.rb +0 -422
  485. data/lib/measures/IncreaseInsulationRValueForRoofs/measure.xml +0 -143
  486. data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/LICENSE.md +0 -27
  487. data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/README.md +0 -32
  488. data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/README.md.erb +0 -42
  489. data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/measure.rb +0 -328
  490. data/lib/measures/IncreaseInsulationRValueForRoofsByPercentage/measure.xml +0 -98
  491. data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/LICENSE.md +0 -27
  492. data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md +0 -97
  493. data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md.erb +0 -42
  494. data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.rb +0 -450
  495. data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.xml +0 -186
  496. data/lib/measures/ReduceLightingLoadsByPercentage/LICENSE.md +0 -27
  497. data/lib/measures/ReduceLightingLoadsByPercentage/README.md +0 -96
  498. data/lib/measures/ReduceLightingLoadsByPercentage/README.md.erb +0 -42
  499. data/lib/measures/ReduceLightingLoadsByPercentage/measure.rb +0 -513
  500. data/lib/measures/ReduceLightingLoadsByPercentage/measure.xml +0 -191
  501. data/lib/measures/ReduceSpaceInfiltrationByPercentage/LICENSE.md +0 -27
  502. data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md +0 -104
  503. data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md.erb +0 -42
  504. data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.rb +0 -349
  505. data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.xml +0 -181
  506. data/lib/measures/ReduceVentilationByPercentage/LICENSE.md +0 -27
  507. data/lib/measures/ReduceVentilationByPercentage/README.md +0 -40
  508. data/lib/measures/ReduceVentilationByPercentage/README.md.erb +0 -42
  509. data/lib/measures/ReduceVentilationByPercentage/measure.rb +0 -291
  510. data/lib/measures/ReduceVentilationByPercentage/measure.xml +0 -96
  511. data/lib/measures/VentilationQAQC/ExampleModel.osm +0 -28468
  512. data/lib/measures/create_variable_speed_rtu/LICENSE.md +0 -27
  513. data/lib/measures/create_variable_speed_rtu/README.md +0 -120
  514. data/lib/measures/create_variable_speed_rtu/README.md.erb +0 -42
  515. data/lib/measures/create_variable_speed_rtu/measure.rb +0 -539
  516. data/lib/measures/create_variable_speed_rtu/measure.xml +0 -207
  517. data/lib/measures/generic_qaqc/resources/os_lib_helper_methods.rb +0 -399
  518. data/lib/measures/openstudio_results/resources/os_lib_helper_methods.rb +0 -399
  519. data/lib/measures/openstudio_results/resources/os_lib_schedules.rb +0 -960
  520. data/lib/measures/radiant_slab_with_doas/LICENSE.md +0 -27
  521. data/lib/measures/radiant_slab_with_doas/README.md +0 -156
  522. data/lib/measures/radiant_slab_with_doas/README.md.erb +0 -42
  523. data/lib/measures/radiant_slab_with_doas/measure.rb +0 -403
  524. data/lib/measures/radiant_slab_with_doas/measure.xml +0 -345
@@ -1,521 +0,0 @@
1
- # *******************************************************************************
2
- # OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC.
3
- # All rights reserved.
4
- # Redistribution and use in source and binary forms, with or without
5
- # modification, are permitted provided that the following conditions are met:
6
- #
7
- # (1) Redistributions of source code must retain the above copyright notice,
8
- # this list of conditions and the following disclaimer.
9
- #
10
- # (2) Redistributions in binary form must reproduce the above copyright notice,
11
- # this list of conditions and the following disclaimer in the documentation
12
- # and/or other materials provided with the distribution.
13
- #
14
- # (3) Neither the name of the copyright holder nor the names of any contributors
15
- # may be used to endorse or promote products derived from this software without
16
- # specific prior written permission from the respective party.
17
- #
18
- # (4) Other than as required in clauses (1) and (2), distributions in any form
19
- # of modifications or other derivative works may not use the "OpenStudio"
20
- # trademark, "OS", "os", or any other confusingly similar designation without
21
- # specific prior written permission from Alliance for Sustainable Energy, LLC.
22
- #
23
- # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS
24
- # "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
25
- # THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
26
- # ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE
27
- # UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF
28
- # THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
29
- # EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT
30
- # OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
31
- # INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
32
- # STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
33
- # OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
34
- # *******************************************************************************
35
-
36
- # start the measure
37
- class AddDaylightSensors < OpenStudio::Measure::ModelMeasure
38
- # define the name that a user will see
39
- def name
40
- return 'Add Daylight Sensor at the Center of Spaces with a Specified Space Type Assigned'
41
- end
42
-
43
- # human readable description
44
- def description
45
- return 'This measure will add daylighting controls to spaces that that have space types assigned with names containing the string in the argument. You can also add a cost per space for sensors added to the model.'
46
- end
47
-
48
- # human readable description of modeling approach
49
- def modeler_description
50
- return "Make an array of the spaces that meet the criteria. Locate the sensor x and y values by averaging the min and max X and Y values from floor surfaces in the space. If a space already has a daylighting control, do not add a new one and leave the original in place. Warn the user if the space isn't assigned to a thermal zone, or if the space doesn't have any translucent surfaces. Note that the cost is added to the space not the sensor. If the sensor is removed at a later date, the cost will remain."
51
- end
52
-
53
- # define the arguments that the user will input
54
- def arguments(model)
55
- args = OpenStudio::Measure::OSArgumentVector.new
56
-
57
- # make a choice argument for model objects
58
- space_type_handles = OpenStudio::StringVector.new
59
- space_type_display_names = OpenStudio::StringVector.new
60
-
61
- # putting model object and names into hash
62
- space_type_args = model.getSpaceTypes
63
- space_type_args_hash = {}
64
- space_type_args.each do |space_type_arg|
65
- space_type_args_hash[space_type_arg.name.to_s] = space_type_arg
66
- end
67
-
68
- # looping through sorted hash of model objects
69
- space_type_args_hash.sort.map do |key, value|
70
- # only include if space type is used in the model
71
- if !value.spaces.empty?
72
- space_type_handles << value.handle.to_s
73
- space_type_display_names << key
74
- end
75
- end
76
-
77
- # make a choice argument for space type
78
- space_type = OpenStudio::Measure::OSArgument.makeChoiceArgument('space_type', space_type_handles, space_type_display_names, true)
79
- space_type.setDisplayName('Add Daylight Sensors to Spaces of This Space Type')
80
- args << space_type
81
-
82
- # make an argument for setpoint
83
- setpoint = OpenStudio::Measure::OSArgument.makeDoubleArgument('setpoint', true)
84
- setpoint.setDisplayName('Daylighting Setpoint')
85
- setpoint.setUnits('fc')
86
- setpoint.setDefaultValue(45.0)
87
- args << setpoint
88
-
89
- # make an argument for control_type
90
- chs = OpenStudio::StringVector.new
91
- chs << 'None'
92
- chs << 'Continuous'
93
- chs << 'Stepped'
94
- chs << 'Continuous/Off'
95
- control_type = OpenStudio::Measure::OSArgument.makeChoiceArgument('control_type', chs)
96
- control_type.setDisplayName('Daylighting Control Type')
97
- control_type.setDefaultValue('Continuous/Off')
98
- args << control_type
99
-
100
- # make an argument for min_power_fraction
101
- min_power_fraction = OpenStudio::Measure::OSArgument.makeDoubleArgument('min_power_fraction', true)
102
- min_power_fraction.setDisplayName('Daylighting Minimum Input Power Fraction')
103
- min_power_fraction.setDescription('min = 0 max = 0.6')
104
- min_power_fraction.setDefaultValue(0.3)
105
- args << min_power_fraction
106
-
107
- # make an argument for min_light_fraction
108
- min_light_fraction = OpenStudio::Measure::OSArgument.makeDoubleArgument('min_light_fraction', true)
109
- min_light_fraction.setDisplayName('Daylighting Minimum Light Output Fraction')
110
- min_light_fraction.setDescription('min = 0 max = 0.6')
111
- min_light_fraction.setDefaultValue(0.2)
112
- args << min_light_fraction
113
-
114
- # make an argument for fraction_zone_controlled
115
- fraction_zone_controlled = OpenStudio::Measure::OSArgument.makeDoubleArgument('fraction_zone_controlled', true)
116
- fraction_zone_controlled.setDisplayName('Fraction of zone controlled by daylight sensors')
117
- fraction_zone_controlled.setDefaultValue(1.0)
118
- args << fraction_zone_controlled
119
-
120
- # make an argument for height
121
- height = OpenStudio::Measure::OSArgument.makeDoubleArgument('height', true)
122
- height.setDisplayName('Sensor Height')
123
- height.setUnits('inches')
124
- height.setDefaultValue(30.0)
125
- args << height
126
-
127
- # make an argument for material and installation cost
128
- material_cost = OpenStudio::Measure::OSArgument.makeDoubleArgument('material_cost', true)
129
- material_cost.setDisplayName('Material and Installation Costs per Space for Daylight Sensor')
130
- material_cost.setUnits('$')
131
- material_cost.setDefaultValue(0.0)
132
- args << material_cost
133
-
134
- # make an argument for demolition cost
135
- demolition_cost = OpenStudio::Measure::OSArgument.makeDoubleArgument('demolition_cost', true)
136
- demolition_cost.setDisplayName('Demolition Costs per Space for Daylight Sensor')
137
- demolition_cost.setUnits('$')
138
- demolition_cost.setDefaultValue(0.0)
139
- args << demolition_cost
140
-
141
- # make an argument for duration in years until costs start
142
- years_until_costs_start = OpenStudio::Measure::OSArgument.makeIntegerArgument('years_until_costs_start', true)
143
- years_until_costs_start.setDisplayName('Years Until Costs Start')
144
- years_until_costs_start.setUnits('whole years')
145
- years_until_costs_start.setDefaultValue(0)
146
- args << years_until_costs_start
147
-
148
- # make an argument to determine if demolition costs should be included in initial construction
149
- demo_cost_initial_const = OpenStudio::Measure::OSArgument.makeBoolArgument('demo_cost_initial_const', true)
150
- demo_cost_initial_const.setDisplayName('Demolition Costs Occur During Initial Construction')
151
- demo_cost_initial_const.setDefaultValue(false)
152
- args << demo_cost_initial_const
153
-
154
- # make an argument for expected life
155
- expected_life = OpenStudio::Measure::OSArgument.makeIntegerArgument('expected_life', true)
156
- expected_life.setDisplayName('Expected Life')
157
- expected_life.setUnits('whole years')
158
- expected_life.setDefaultValue(20)
159
- args << expected_life
160
-
161
- # make an argument for o&m cost
162
- om_cost = OpenStudio::Measure::OSArgument.makeDoubleArgument('om_cost', true)
163
- om_cost.setDisplayName('O & M Costs per Space for Daylight Sensor')
164
- om_cost.setUnits('$')
165
- om_cost.setDefaultValue(0.0)
166
- args << om_cost
167
-
168
- # make an argument for o&m frequency
169
- om_frequency = OpenStudio::Measure::OSArgument.makeIntegerArgument('om_frequency', true)
170
- om_frequency.setDisplayName('O & M Frequency')
171
- om_frequency.setUnits('whole years')
172
- om_frequency.setDefaultValue(1)
173
- args << om_frequency
174
-
175
- return args
176
- end
177
-
178
- # define what happens when the measure is run
179
- def run(model, runner, user_arguments)
180
- super(model, runner, user_arguments)
181
-
182
- # use the built-in error checking
183
- if !runner.validateUserArguments(arguments(model), user_arguments)
184
- return false
185
- end
186
-
187
- # assign the user inputs to variables
188
- space_type = runner.getOptionalWorkspaceObjectChoiceValue('space_type', user_arguments, model)
189
- setpoint = runner.getDoubleArgumentValue('setpoint', user_arguments)
190
- control_type = runner.getStringArgumentValue('control_type', user_arguments)
191
- min_power_fraction = runner.getDoubleArgumentValue('min_power_fraction', user_arguments)
192
- min_light_fraction = runner.getDoubleArgumentValue('min_light_fraction', user_arguments)
193
- fraction_zone_controlled = runner.getDoubleArgumentValue('fraction_zone_controlled', user_arguments)
194
- height = runner.getDoubleArgumentValue('height', user_arguments)
195
- material_cost = runner.getDoubleArgumentValue('material_cost', user_arguments)
196
- demolition_cost = runner.getDoubleArgumentValue('demolition_cost', user_arguments)
197
- years_until_costs_start = runner.getIntegerArgumentValue('years_until_costs_start', user_arguments)
198
- demo_cost_initial_const = runner.getBoolArgumentValue('demo_cost_initial_const', user_arguments)
199
- expected_life = runner.getIntegerArgumentValue('expected_life', user_arguments)
200
- om_cost = runner.getDoubleArgumentValue('om_cost', user_arguments)
201
- om_frequency = runner.getIntegerArgumentValue('om_frequency', user_arguments)
202
-
203
- # check the space_type for reasonableness
204
- if space_type.empty?
205
- handle = runner.getStringArgumentValue('space_type', user_arguments)
206
- if handle.empty?
207
- runner.registerError('No SpaceType was chosen.')
208
- else
209
- runner.registerError("The selected space type with handle '#{handle}' was not found in the model. It may have been removed by another measure.")
210
- end
211
- return false
212
- else
213
- if !space_type.get.to_SpaceType.empty?
214
- space_type = space_type.get.to_SpaceType.get
215
- else
216
- runner.registerError('Script Error - argument not showing up as space type.')
217
- return false
218
- end
219
- end
220
-
221
- # check the setpoint for reasonableness
222
- if (setpoint < 0) || (setpoint > 9999) # dfg need input on good value
223
- runner.registerError("A setpoint of #{setpoint} foot-candles is outside the measure limit.")
224
- return false
225
- elsif setpoint > 999
226
- runner.registerWarning("A setpoint of #{setpoint} foot-candles is abnormally high.") # dfg need input on good value
227
- end
228
-
229
- # check the min_power_fraction for reasonableness
230
- if (min_power_fraction < 0.0) || (min_power_fraction > 0.6)
231
- runner.registerError("The requested minimum input power fraction of #{min_power_fraction} for continuous dimming control is outside the acceptable range of 0 to 0.6.")
232
- return false
233
- end
234
-
235
- # check the min_light_fraction for reasonableness
236
- if (min_light_fraction < 0.0) || (min_light_fraction > 0.6)
237
- runner.registerError("The requested minimum light output fraction of #{min_light_fraction} for continuous dimming control is outside the acceptable range of 0 to 0.6.")
238
- return false
239
- end
240
-
241
- # check the height for reasonableness
242
- if (height < -360) || (height > 360) # neg ok because space origin may not be floor
243
- runner.registerError("A setpoint of #{height} inches is outside the measure limit.")
244
- return false
245
- elsif height > 72
246
- runner.registerWarning("A setpoint of #{height} inches is abnormally high.")
247
- elseif height < 0
248
- runner.registerWarning('Typically the sensor height should be a positive number, however if your space origin is above the floor then a negative sensor height may be approriate.')
249
- end
250
-
251
- # set flags to use later
252
- costs_requested = false
253
- warning_cost_assign_to_space = false
254
-
255
- # check costs for reasonableness
256
- if material_cost.abs + demolition_cost.abs + om_cost.abs == 0
257
- runner.registerInfo('No costs were requested for Daylight Sensors.')
258
- else
259
- costs_requested = true
260
- end
261
-
262
- # check lifecycle arguments for reasonableness
263
- if (years_until_costs_start < 0) && (years_until_costs_start > expected_life)
264
- runner.registerError('Years until costs start should be a non-negative integer less than Expected Life.')
265
- end
266
- if (expected_life < 1) && (expected_life > 100)
267
- runner.registerError('Choose an integer greater than 0 and less than or equal to 100 for Expected Life.')
268
- end
269
- if om_frequency < 1
270
- runner.registerError('Choose an integer greater than 0 for O & M Frequency.')
271
- end
272
-
273
- # short def to make numbers pretty (converts 4125001.25641 to 4,125,001.26 or 4,125,001). The definition be called through this measure
274
- def neat_numbers(number, roundto = 2) # round to 0 or 2)
275
- if roundto == 2
276
- number = format '%.2f', number
277
- else
278
- number = number.round
279
- end
280
- # regex to add commas
281
- number.to_s.reverse.gsub(/([0-9]{3}(?=([0-9])))/, '\\1,').reverse
282
- end
283
-
284
- # helper that loops through lifecycle costs getting total costs under "Construction" or "Salvage" category and add to counter if occurs during year 0
285
- def get_total_costs_for_objects(objects)
286
- counter = 0
287
- objects.each do |object|
288
- object_LCCs = object.lifeCycleCosts
289
- object_LCCs.each do |object_LCC|
290
- if (object_LCC.category == 'Construction') || (object_LCC.category == 'Salvage')
291
- if object_LCC.yearsFromStart == 0
292
- counter += object_LCC.totalCost
293
- end
294
- end
295
- end
296
- end
297
- return counter
298
- end
299
-
300
- # unit conversion from IP units to SI units
301
- setpoint_si = OpenStudio.convert(setpoint, 'fc', 'lux').get
302
- height_si = OpenStudio.convert(height, 'in', 'm').get
303
-
304
- # variable to tally the area to which the overall measure is applied
305
- area = 0
306
- # variables to aggregate the number of sensors installed and the area affected
307
- sensor_count = 0
308
- sensor_area = 0
309
- spaces_using_space_type = space_type.spaces
310
- # array with subset of spaces
311
- spaces_using_space_type_in_zones_without_sensors = []
312
- affected_zones = []
313
- affected_zone_names = []
314
- # hash to hold sensor objects
315
- new_sensor_objects = {}
316
-
317
- # reporting initial condition of model
318
- starting_spaces = model.getSpaces
319
- runner.registerInitialCondition("#{spaces_using_space_type.size} spaces are assigned to space type '#{space_type.name}'.")
320
-
321
- # get starting costs for spaces
322
- yr0_capital_totalCosts = -1 * get_total_costs_for_objects(spaces_using_space_type)
323
-
324
- # test that there is no sensor already in the space, and that zone object doesn't already have sensors assigned.
325
- spaces_using_space_type.each do |space_using_space_type|
326
- if space_using_space_type.daylightingControls.empty?
327
- space_zone = space_using_space_type.thermalZone
328
- if !space_zone.empty?
329
- space_zone = space_zone.get
330
- if space_zone.primaryDaylightingControl.empty? && space_zone.secondaryDaylightingControl.empty?
331
- spaces_using_space_type_in_zones_without_sensors << space_using_space_type
332
- elsif
333
- runner.registerWarning("Thermal zone '#{space_zone.name}' which includes space '#{space_using_space_type.name}' already had a daylighting sensor. No sensor was added to space '#{space_using_space_type.name}'.")
334
- end
335
- else
336
- runner.registerWarning("Space '#{space_using_space_type.name}' is not associated with a thermal zone. It won't be part of the EnergyPlus simulation.")
337
- end
338
- else
339
- runner.registerWarning("Space '#{space_using_space_type.name}' already has a daylighting sensor. No sensor was added.")
340
- end
341
- end
342
-
343
- # loop through all spaces,
344
- # and add a daylighting sensor with dimming to each
345
- space_count = 0
346
- spaces_using_space_type_in_zones_without_sensors.each do |space|
347
- space_count += 1
348
- area += space.floorArea
349
-
350
- # eliminate spaces that don't have exterior natural lighting
351
- has_ext_nat_light = false
352
- space.surfaces.each do |surface|
353
- next if surface.outsideBoundaryCondition != 'Outdoors'
354
- surface.subSurfaces.each do |sub_surface|
355
- next if sub_surface.subSurfaceType == 'Door'
356
- next if sub_surface.subSurfaceType == 'OverheadDoor'
357
- has_ext_nat_light = true
358
- end
359
- end
360
- if has_ext_nat_light == false
361
- runner.registerWarning("Space '#{space.name}' has no exterior natural lighting. No sensor will be added.")
362
- next
363
- end
364
-
365
- # find floors
366
- floors = []
367
- space.surfaces.each do |surface|
368
- next if surface.surfaceType != 'Floor'
369
- floors << surface
370
- end
371
-
372
- # this method only works for flat (non-inclined) floors
373
- boundingBox = OpenStudio::BoundingBox.new
374
- floors.each do |floor|
375
- boundingBox.addPoints(floor.vertices)
376
- end
377
- xmin = boundingBox.minX.get
378
- ymin = boundingBox.minY.get
379
- zmin = boundingBox.minZ.get
380
- xmax = boundingBox.maxX.get
381
- ymax = boundingBox.maxY.get
382
-
383
- # create a new sensor and put at the center of the space
384
- sensor = OpenStudio::Model::DaylightingControl.new(model)
385
- sensor.setName("#{space.name} daylighting control")
386
- x_pos = (xmin + xmax) / 2
387
- y_pos = (ymin + ymax) / 2
388
- z_pos = zmin + height_si # put it 1 meter above the floor
389
- new_point = OpenStudio::Point3d.new(x_pos, y_pos, z_pos)
390
- sensor.setPosition(new_point)
391
- sensor.setIlluminanceSetpoint(setpoint_si)
392
- sensor.setLightingControlType(control_type)
393
- sensor.setMinimumInputPowerFractionforContinuousDimmingControl(min_power_fraction)
394
- sensor.setMinimumLightOutputFractionforContinuousDimmingControl(min_light_fraction)
395
- sensor.setSpace(space)
396
- puts sensor
397
-
398
- # add lifeCycleCost objects if there is a non-zero value in one of the cost arguments
399
- if costs_requested == true
400
-
401
- starting_lcc_counter = space.lifeCycleCosts.size
402
-
403
- # adding new cost items
404
- lcc_mat = OpenStudio::Model::LifeCycleCost.createLifeCycleCost("LCC_Mat - #{sensor.name}", space, material_cost, 'CostPerEach', 'Construction', expected_life, years_until_costs_start)
405
- if demo_cost_initial_const
406
- lcc_demo = OpenStudio::Model::LifeCycleCost.createLifeCycleCost("LCC_Demo - #{sensor.name}", space, demolition_cost, 'CostPerEach', 'Salvage', expected_life, years_until_costs_start)
407
- else
408
- lcc_demo = OpenStudio::Model::LifeCycleCost.createLifeCycleCost("LCC_Demo - #{sensor.name}", space, demolition_cost, 'CostPerEach', 'Salvage', expected_life, years_until_costs_start + expected_life)
409
- end
410
- lcc_om = OpenStudio::Model::LifeCycleCost.createLifeCycleCost("LCC_OM - #{sensor.name}", space, om_cost, 'CostPerEach', 'Maintenance', om_frequency, 0)
411
-
412
- if space.lifeCycleCosts.size - starting_lcc_counter == 3
413
- if !warning_cost_assign_to_space
414
- runner.registerInfo('Cost for daylight sensors was added to spaces. The cost will remain in the model unless the space is removed. Removing only the sensor will not remove the cost.')
415
- warning_cost_assign_to_space = true
416
- end
417
- else
418
- runner.registerWarning("The measure did not function as expected. #{space.lifeCycleCosts.size - starting_lcc_counter} LifeCycleCost objects were made, 3 were expected.")
419
- end
420
-
421
- end
422
-
423
- # push unique zones to array for use later in measure
424
- temp_zone = space.thermalZone.get
425
- if affected_zone_names.include?(temp_zone.name.to_s) == false
426
- affected_zones << temp_zone
427
- affected_zone_names << temp_zone.name.to_s
428
- end
429
-
430
- # push sensor object into hash with space name
431
- new_sensor_objects[space.name.to_s] = sensor
432
-
433
- # add floor area to the daylighting area tally
434
- sensor_area += space.floorArea
435
-
436
- # add to sensor count for reporting
437
- sensor_count += 1
438
- end
439
-
440
- if (sensor_count == 0) && (costs_requested == false)
441
- runner.registerAsNotApplicable("No spaces that currently don't have sensor required a new sensor, and no lifecycle costs objects were requested.")
442
- return true
443
- end
444
-
445
- # loop through thermal Zones for spaces with daylighting controls added
446
- affected_zones.each do |zone|
447
- zone_spaces = zone.spaces
448
- zone_spaces_with_new_sensors = []
449
- zone_spaces.each do |zone_space|
450
- if !zone_space.daylightingControls.empty? && (zone_space.spaceType.get == space_type)
451
- zone_spaces_with_new_sensors << zone_space
452
- end
453
- end
454
-
455
- if !zone_spaces_with_new_sensors.empty?
456
- # need to identify the two largest spaces
457
- primary_area = 0
458
- secondary_area = 0
459
- primary_space = nil
460
- secondary_space = nil
461
- three_or_more_sensors = false
462
-
463
- # dfg temp - need to add another if statement so only get spaces with sensors
464
- zone_spaces_with_new_sensors.each do |zone_space|
465
- zone_space_area = zone_space.floorArea
466
- if zone_space_area > primary_area
467
- primary_area = zone_space_area
468
- primary_space = zone_space
469
- elsif zone_space_area > secondary_area
470
- secondary_area = zone_space_area
471
- secondary_space = zone_space
472
- else
473
- # setup flag to warn user that more than 2 sensors can't be added to a space
474
- three_or_more_sensors = true
475
- end
476
- end
477
-
478
- if primary_space
479
- # setup primary sensor
480
- sensor_primary = new_sensor_objects[primary_space.name.to_s]
481
- zone.setPrimaryDaylightingControl(sensor_primary)
482
- zone.setFractionofZoneControlledbyPrimaryDaylightingControl(fraction_zone_controlled * primary_area / (primary_area + secondary_area))
483
- end
484
-
485
- if secondary_space
486
- # setup secondary sensor
487
- sensor_secondary = new_sensor_objects[secondary_space.name.to_s]
488
- zone.setSecondaryDaylightingControl(sensor_secondary)
489
- zone.setFractionofZoneControlledbySecondaryDaylightingControl(fraction_zone_controlled * secondary_area / (primary_area + secondary_area))
490
- end
491
-
492
- # warn that additional sensors were not used
493
- if three_or_more_sensors == true
494
- runner.registerWarning("Thermal zone '#{zone.name}' had more than two spaces with sensors. Only two sensors were associated with the thermal zone.")
495
- end
496
-
497
- end
498
- end
499
-
500
- # setup OpenStudio units that we will need
501
- unit_area_ip = OpenStudio.createUnit('ft^2').get
502
- unit_area_si = OpenStudio.createUnit('m^2').get
503
-
504
- # define starting units
505
- area_si = OpenStudio::Quantity.new(sensor_area, unit_area_si)
506
-
507
- # unit conversion from IP units to SI units
508
- area_ip = OpenStudio.convert(area_si, unit_area_ip).get
509
-
510
- # get final costs for spaces
511
- yr0_capital_totalCosts = get_total_costs_for_objects(spaces_using_space_type)
512
-
513
- # reporting final condition of model
514
- runner.registerFinalCondition("Added daylighting controls to #{sensor_count} spaces, covering #{area_ip}. Initial year costs associated with the daylighting controls is $#{neat_numbers(yr0_capital_totalCosts, 0)}.")
515
-
516
- return true
517
- end
518
- end
519
-
520
- # this allows the measure to be used by the application
521
- AddDaylightSensors.new.registerWithApplication